WorldWideScience

Sample records for test setup spats

  1. Experimental infection of Pacific oyster Crassostrea gigas spat by ostreid herpesvirus 1: demonstration of oyster spat susceptibility

    Directory of Open Access Journals (Sweden)

    Schikorski David

    2011-02-01

    Full Text Available Abstract In 2008 and 2009, acute mortalities occurred in France among Pacific cupped oyster, Crassostrea gigas, spat. Different hypothesis including the implication of environmental factors, toxic algae and/or pathogens have been explored. Diagnostic tests indicated that OsHV-1 including a particular genotype, termed OsHV-1 μVar, was detected in most of samples and especially in moribund oysters with the highlighting of virus particles looking like herpes viruses by TEM examination. In this study, an experimental protocol to reproduce OsHV-1 infection in laboratory conditions was developed. This protocol was based on the intramuscular injection of filtered (0.22 μm tissue homogenates prepared from naturally OsHV-1 infected spat collected on French coasts during mortality outbreaks in 2008. Results of the experimental trials showed that mortalities were induced after injection. Moreover, filtered tissue homogenates induced mortalities whereas the same tissue homogenates exposed to an ultraviolet (UV treatment did not induce any mortality suggesting that oyster spat mortalities require the presence of a UV sensitive agent. Furthermore, analysis of injected oyster spat revealed the detection of high amounts of OsHV-1 DNA by real-time quantitative PCR. Finally, TEM analysis demonstrated the presence of herpes virus particles. The developed protocol allowed to maintain sources of infective virus which can be useful for the development of further studies concerning the transmission and the development of OsHV-1 infection.

  2. SpatEntropy: Spatial Entropy Measures in R

    OpenAIRE

    Altieri, Linda; Cocchi, Daniela; Roli, Giulia

    2018-01-01

    This article illustrates how to measure the heterogeneity of spatial data presenting a finite number of categories via computation of spatial entropy. The R package SpatEntropy contains functions for the computation of entropy and spatial entropy measures. The extension to spatial entropy measures is a unique feature of SpatEntropy. In addition to the traditional version of Shannon's entropy, the package includes Batty's spatial entropy, O'Neill's entropy, Li and Reynolds' contagion index, Ka...

  3. Cornstarch as a dietary supplement in conditioning broodstock and spat at a nursery of the Pacific calico scallop, Argopecten ventricosus

    OpenAIRE

    Mazón-Suástegui, José Manuel; Lodeiros, Cesar; Avilés-Quevedo, Araceli; Rodríguez-Jaramillo, Carmen; Ortiz-Cornejo, Nadia; Abasolo-Pacheco, Fernando

    2017-01-01

    ABSTRACT Microalgae diets supplemented with cornstarch at a rate of 0.15% of live weight to the conditioning of broodstock and spat growth of Pacific calico scallop Argopecten ventricosus were tested. To determine reproductive condition at the beginning and end of the experiment, the gonads of adults were analyzed by stereological methods. For juveniles, the weekly percent increase of spat was estimated from spat biomass volume. The microalgae diet of Tisochrysis lutea and Chaetoceros calcitr...

  4. Corals like it waxed: paraffin-based antifouling technology enhances coral spat survival.

    Directory of Open Access Journals (Sweden)

    Jan Tebben

    Full Text Available The early post-settlement stage is the most sensitive during the life history of reef building corals. However, few studies have examined the factors that influence coral mortality during this period. Here, the impact of fouling on the survival of newly settled coral spat of Acropora millepora was investigated by manipulating the extent of fouling cover on settlement tiles using non-toxic, wax antifouling coatings. Survival of spat on coated tiles was double that on control tiles. Moreover, there was a significant negative correlation between percentage cover of fouling and spat survival across all tiles types, suggesting that fouling in direct proximity to settled corals has detrimental effects on early post-settlement survival. While previous studies have shown that increased fouling negatively affects coral larval settlement and health of juvenile and adult corals, to the best of our knowledge, this is the first study to show a direct relationship between fouling and early post-settlement survival for a broadcast spawning scleractinian coral. The negative effects of fouling on this sensitive life history stage may become more pronounced in the future as coastal eutrophication increases. Our results further suggest that targeted seeding of coral spat on artificial surfaces in combination with fouling control could prove useful to improve the efficiency of sexual reproduction-based coral propagation for reef rehabilitation.

  5. SPAT 15 - Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Bartley, J.C. (Coordinator)

    1998-08-01

    In the Spring of 1997, the Department of Energy's Department Standards Committee (DSC) convened a Standards Process Action Team (SPAT-15) to evaluate assessment processes within the DOE complex. If time and resources permitted, the team was also to evaluate assessment processes used by private industry conducting similar work and activities. The specific task statement was as follows: "Define the attributes of assessment programs that effectively support organizational feedback and improvement of safety systems at all the different levels of contractor and Department organizations." The team gathered information on existing assessment programs through surveys and presentations by representatives from national laboratories, processing facilities, and remediation sites. Examples of assessment programs described in this report encompass site-wide, individual facility, and task level applications within the DOE compIex

  6. SPAT 15 - Assessment

    International Nuclear Information System (INIS)

    Bartley, J.C.

    1998-01-01

    In the Spring of 1997, the Department of Energy's Department Standards Committee (DSC) convened a Standards Process Action Team (SPAT-15) to evaluate assessment processes within the DOE complex. If time and resources permitted, the team was also to evaluate assessment processes used by private industry conducting similar work and activities. The specific task statement was as follows: ''Define the attributes of assessment programs that effectively support organizational feedback and improvement of safety systems at all the different levels of contractor and Department organizations.'' The team gathered information on existing assessment programs through surveys and presentations by representatives from national laboratories, processing facilities, and remediation sites. Examples of assessment programs described in this report encompass site-wide, individual facility, and task level applications within the DOE compIex

  7. Developing a national spat collection program for pearl oysters in the Fiji Islands supporting pearl industry development and livelihoods

    Directory of Open Access Journals (Sweden)

    Pranesh Kishore

    2018-02-01

    Full Text Available Cultured pearl farming in Fiji relies on wild spat collection to supply the oysters used for pearl production. This supply can be inconsistent and a research program was implemented to determine recruitment of pearl oysters to spat collectors at sites throughout Fiji as a basis for developing a national spat collection program to improve reliability of oyster supply to the industry. Twenty-nine sites across Fiji were used in this study. Spat collectors consisted of a 100 m longline from which 310 individual spat collectors were suspended. Spat collectors were deployed for a period of 10–15 months when the number of pearl oyster (Pinctada margaritifera and Pteria penguin spat attached to each collector was counted and shell size recorded. A total of 5478 P. margaritifera juveniles were collected from all sites with the highest number of recruits (693 and the highest number of recruits per collector (2.10 ± 0.17 occurring at Nacobau (Vanua Levu. The largest mean dorso-ventral measurement (DVM of P. margaritifera at any site was 8.61 ± 0.30 cm while the smallest was 4.26 ± 0.13 cm. Some sites did not record any P. margaritifera recruitment during the study and these were generally sites with relatively turbid water. A total of 4224 Pt. penguin were collected from all sites, with the highest number of recruits (495 recorded from Namarai (Viti Levu. The mean DVM of Pt. penguin ranged from 7.53 cm to 13.62 cm across sites. Results indicate that Pt. penguin have greater tolerance of more turbid inshore sites than P. margaritifera based on greater levels of recruitment at these sites. Results identified sites supporting high levels of pearl oyster recruitment as a basis for an ongoing national spat collection program, and support better targeting of spat collection activities that maximise oyster supply to the Fijian pearl industry. The national spat collection program will generate significant livelihood benefits across

  8. Detection and distribution of ostreid herpesvirus 1 in experimentally infected Pacific oyster spat.

    Science.gov (United States)

    Segarra, Amélie; Baillon, Laury; Faury, Nicole; Tourbiez, Delphine; Renault, Tristan

    2016-01-01

    High mortality rates are reported in spat and larvae of Pacific oyster Crassostrea gigas and associated with ostreid herpesvirus 1 (OsHV-1) detection in France. Although the viral infection has been experimentally reproduced in oyster larvae and spat, little knowledge is currently available concerning the viral entry and its distribution in organs and tissues. This study compares OsHV-1 DNA and RNA detection and localization in experimentally infected oysters using two virus doses: a low dose that did not induce any mortality and a high dose inducing high mortality. Real time PCR demonstrated significant differences in terms of viral DNA amounts between the two virus doses. RNA transcripts were detected in oysters receiving the highest dose of viral suspension whereas no transcript was observed in oysters injected with the low dose. This study also allowed observing kinetics of viral DNA and RNA detection in different tissues of oyster spat. Finally, viral detection was significantly different in function of tissues (p<0.005), time (p<0.005) with an interaction between tissues and time (p<0.005) for each probe. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Mussel Spat Ropes Assist Redfin Bully Gobiomorphus huttoni Passage through Experimental Culverts with Velocity Barriers

    Directory of Open Access Journals (Sweden)

    Jonathan D. Tonkin

    2012-09-01

    Full Text Available The application of mussel spat rope for enabling the passage of redfin bully Gobiomorphus huttoni through culverts, which create velocity barriers, was trialled in the laboratory. No fish were able to access the un-roped control pipes whereas 52% successfully negotiated the pipes in the rope treatments. The success of fish ascending treatment pipes suggests mussel spat rope may be effective for enabling the passage of this and other similar fish species through otherwise impassable culverts with velocity barriers.

  10. Set-up for differential manometers testing

    International Nuclear Information System (INIS)

    Ratushnyj, M.I.; Galkin, Yu.V.; Nechaj, A.G.

    1985-01-01

    Set-up characteristic for controlling and testing metrological characteristics of TPP and NPP differential manometers with extreme pressure drop upto 250 kPa is briefly described. The set-up provides with automatic and manual assignment of values of gauge air pressure with errors of 0.1 and 0.25% correspondingly. The set-up is supplied with standard equipment to measure output signals. Set-up supply is carried out by a one-phase alternating current circuit with 220 V. Air supply is carried out by O.4-0.6 MPa. pressure of a pneumatic system. Application of the set-up increases operating efficiency 5 times while checking and turning differential manometers

  11. Transcriptional changes in Crassostrea gigas oyster spat following a parental exposure to the herbicide diuron

    International Nuclear Information System (INIS)

    Rondon, R.; Akcha, F.; Alonso, P.; Menard, D.; Rouxel, J.; Montagnani, C.; Mitta, G.; Cosseau, C.; Grunau, C.

    2016-01-01

    Highlights: • Remodeling of the transcriptome of the offspring of oysters exposed to diuron (838 gene which expression is modulated). • Functions related to cytoskeleton organization, translation, ATP synthesis were activated. • Functions linked to transcription and protein degradation were altered. • Up-regulation of genes involved in energy production, protein synthesis and mitosis. • Catch-up growth phenomenon could allow the spats to compensate for slower growth. - Abstract: The Pacific oyster Crassostrea gigas is the main oyster species produced in the world, and a key coastal economic resource in France. High mortalities affect Pacific oysters since 2008 in France and Europe. Their origins have been attributed to a combination of biotic and abiotic factors, underlining the importance of environment quality. The impact of water pollution has been pointed out and one of the pollutants, the genotoxic herbicide diuron, occurs at high concentrations all along the French coasts. Previous work has revealed that a parental exposure to diuron had a strong impact on hatching rates and offspring development even if spats were not exposed to diuron themselves. In this study, we explored for the first time the transcriptional changes occurring in oyster spats (non exposed) originating from genitors exposed to an environmentally relevant concentration of diuron during gametogenesis using the RNAseq methodology. We identified a transcriptomic remodeling revealing an effect of the herbicide. Different molecular pathways involved in energy production, translation and cell proliferation are particularly disturbed. This analysis revealed modulated candidate genes putatively involved in response to oxidative stress and mitochondrial damage in offspring of genitors exposed to diuron. Complementary measures of the activity of enzymes involved in these latter processes corroborate the results obtained at the transcriptomic level. In addition, our results suggested an

  12. Transcriptional changes in Crassostrea gigas oyster spat following a parental exposure to the herbicide diuron

    Energy Technology Data Exchange (ETDEWEB)

    Rondon, R. [Ifremer, IHPE UMR 5244, Univ. Perpignan Via Domitia, CNRS, Univ. Montpellier, F-34095 Montpellier (France); Univ. Perpignan Via Domitia, IHPE UMR 5244, CNRS, IFREMER, Univ. Montpellier, F-66860 Perpignan (France); Akcha, F. [Ifremer, Department of Biogeochemistry and Ecotoxicology, Laboratory of Ecotoxicology, Rue de l’ile d’Yeu, BP 21105, 44311 Nantes Cedex 03 (France); Alonso, P. [CNRS, IHPE UMR 5244, Univ. Perpignan Via Domitia, IFREMER, Univ. Montpellier, F-34095 Montpellier (France); Menard, D.; Rouxel, J. [Ifremer, Department of Biogeochemistry and Ecotoxicology, Laboratory of Ecotoxicology, Rue de l’ile d’Yeu, BP 21105, 44311 Nantes Cedex 03 (France); Montagnani, C., E-mail: cmontagn@ifremer.fr [Ifremer, IHPE UMR 5244, Univ. Perpignan Via Domitia, CNRS, Univ. Montpellier, F-34095 Montpellier (France); Mitta, G.; Cosseau, C.; Grunau, C. [Univ. Perpignan Via Domitia, IHPE UMR 5244, CNRS, IFREMER, Univ. Montpellier, F-66860 Perpignan (France)

    2016-06-15

    Highlights: • Remodeling of the transcriptome of the offspring of oysters exposed to diuron (838 gene which expression is modulated). • Functions related to cytoskeleton organization, translation, ATP synthesis were activated. • Functions linked to transcription and protein degradation were altered. • Up-regulation of genes involved in energy production, protein synthesis and mitosis. • Catch-up growth phenomenon could allow the spats to compensate for slower growth. - Abstract: The Pacific oyster Crassostrea gigas is the main oyster species produced in the world, and a key coastal economic resource in France. High mortalities affect Pacific oysters since 2008 in France and Europe. Their origins have been attributed to a combination of biotic and abiotic factors, underlining the importance of environment quality. The impact of water pollution has been pointed out and one of the pollutants, the genotoxic herbicide diuron, occurs at high concentrations all along the French coasts. Previous work has revealed that a parental exposure to diuron had a strong impact on hatching rates and offspring development even if spats were not exposed to diuron themselves. In this study, we explored for the first time the transcriptional changes occurring in oyster spats (non exposed) originating from genitors exposed to an environmentally relevant concentration of diuron during gametogenesis using the RNAseq methodology. We identified a transcriptomic remodeling revealing an effect of the herbicide. Different molecular pathways involved in energy production, translation and cell proliferation are particularly disturbed. This analysis revealed modulated candidate genes putatively involved in response to oxidative stress and mitochondrial damage in offspring of genitors exposed to diuron. Complementary measures of the activity of enzymes involved in these latter processes corroborate the results obtained at the transcriptomic level. In addition, our results suggested an

  13. Effects of a parental exposure to diuron on Pacific oyster spat methylome.

    Science.gov (United States)

    Rondon, Rodolfo; Grunau, Christoph; Fallet, Manon; Charlemagne, Nicolas; Sussarellu, Rossana; Chaparro, Cristian; Montagnani, Caroline; Mitta, Guillaume; Bachère, Evelyne; Akcha, Farida; Cosseau, Céline

    2017-01-01

    Environmental epigenetic is an emerging field that studies the cause-effect relationship between environmental factors and heritable trait via an alteration in epigenetic marks. This field has received much attentions since the impact of environmental factors on different epigenetic marks have been shown to be associated with a broad range of phenotypic disorders in natural ecosystems. Chemical pollutants have been shown to affect immediate epigenetic information carriers of several aquatic species but the heritability of the chromatin marks and the consequences for long term adaptation remain open questions. In this work, we investigated the impact of the diuron herbicide on the DNA methylation pattern of spat from exposed Crassotrea gigas genitors. This oyster is one of the most important mollusk species produced worldwide and a key coastal economic resource in France. The whole genome bisulfite sequencing (WGBS, BS-Seq) was applied to obtain a methylome at single nucleotide resolution on DNA extracted from spat issued from diuron exposed genitors comparatively to control spat. We showed that the parental diuron exposure has an impact on the DNA methylation pattern of its progeny. Most of the differentially methylated regions occurred within coding sequences and we showed that this change in methylation level correlates with RNA level only in a very small group of genes. Although the DNA methylation profile is variable between individuals, we showed conserved DNA methylation patterns in response to parental diuron exposure. This relevant result opens perspectives for the setting of new markers based on epimutations as early indicators of marine pollutions.

  14. Mussel Spat Ropes Assist Redfin Bully Gobiomorphus huttoni Passage through Experimental Culverts with Velocity Barriers

    Directory of Open Access Journals (Sweden)

    Liam A.H. Wright

    2012-09-01

    Full Text Available The application of mussel spat rope for enabling the passage of redfin bully Gobiomorphus huttoni through culverts, which create velocity barriers, was trialled in the laboratory. No fish were able to access the un-roped control pipes whereas 52% successfully negotiated the pipes in the rope treatments. The success of fish ascending treatment pipes suggests mussel spat rope may be effective for enabling the passage of this and other similar fish species through otherwise impassable culverts with velocity barriers.

  15. Oyster spat recruitment in Espírito Santo State, Brazil, using recycled materials

    Directory of Open Access Journals (Sweden)

    Rosebel C. Nalesso

    2008-12-01

    Full Text Available This paper evaluated the effectiveness of four types of oyster spat collectors, made with recycled materials, in the recruitment of the mangrove oyster Crassostrea spp. at five sites in the Benevente river estuary, Anchieta District and on two islands in Piúma District, both in Espírito Santo State. The collectors were made of: 1- oyster shells, 2- PET bottles, 3- car tires and 4- tiles, all of them suspended by ropes and tied to roots of Rhizophora mangle or mussel long-lines. The number of spat recruited on each collector and their shell lengths were registered bimonthly, as well as the physico-chemical-trophic parameters of the water: salinity, temperature, dissolved oxygen, particulate organic matter and chlorophyll a, which were correlated (by Spearman's correlation with the number of spat recruited. Spat settlement was significantly higher on oyster shell, tile and tire collectors, mainly at points with higher salinities, such as Praia do Coqueiro in Anchieta and on Meio and Cabrito Islands in Piúma (Kruskal-Wallis: H= 10.01; 3 d.f.; p 0.05. The number of oyster spat was positively correlated with the salinity (ρs= 0.331; p Este trabalho avaliou a eficiência de quatro tipos de coletores de sementes no recrutamento de ostras Crassostrea sp., em cinco pontos do estuário do Rio Benevente, município de Anchieta, e em duas ilhas no município de Piúma, estado do Espírito Santo. Foram utilizados quatro tipos de coletores: 1-conchas de ostras, 2- garrafas PET, 3-tiras de pneu e 4- telhas, todos suspensos por cordas e amarrados em rizóforos de Rhizophora mangle ou em "long-lines" de mexilhões. Bimensalmente, as sementes recrutadas foram contadas e medidas quanto à altura, determinando-se os parâmetros físico-químicos-tróficos da água: salinidade, temperatura, oxigênio dissolvido, matéria orgânica particulada e clorofila-a, que foram correlacionados com o número de sementes nos coletores (através de correlações de Spearman

  16. Transcriptional changes in Crassostrea gigas oyster spat following a parental exposure to the herbicide diuron.

    Science.gov (United States)

    Rondon, R; Akcha, F; Alonso, P; Menard, D; Rouxel, J; Montagnani, C; Mitta, G; Cosseau, C; Grunau, C

    2016-06-01

    The Pacific oyster Crassostrea gigas is the main oyster species produced in the world, and a key coastal economic resource in France. High mortalities affect Pacific oysters since 2008 in France and Europe. Their origins have been attributed to a combination of biotic and abiotic factors, underlining the importance of environment quality. The impact of water pollution has been pointed out and one of the pollutants, the genotoxic herbicide diuron, occurs at high concentrations all along the French coasts. Previous work has revealed that a parental exposure to diuron had a strong impact on hatching rates and offspring development even if spats were not exposed to diuron themselves. In this study, we explored for the first time the transcriptional changes occurring in oyster spats (non exposed) originating from genitors exposed to an environmentally relevant concentration of diuron during gametogenesis using the RNAseq methodology. We identified a transcriptomic remodeling revealing an effect of the herbicide. Different molecular pathways involved in energy production, translation and cell proliferation are particularly disturbed. This analysis revealed modulated candidate genes putatively involved in response to oxidative stress and mitochondrial damage in offspring of genitors exposed to diuron. Complementary measures of the activity of enzymes involved in these latter processes corroborate the results obtained at the transcriptomic level. In addition, our results suggested an increase in energy production and mitotic activity in 5-month-spats from diuron-exposed genitors. These results could correspond to a "catch-up growth" phenomenon allowing the spats from diuron-exposed genitors, which displayed a growth delay at 3 months, to gain a normal size when they reach the age of 6 months. These results indicate that exposure to a concentration of diuron that is frequently encountered in the field during the oyster's gametogenesis stage can impact the next generation

  17. Quick setup of test unit for accelerator control system

    International Nuclear Information System (INIS)

    Fu, W.; D'Ottavio, T.; Gassner, D.; Nemesure, S.; Morris, J.

    2011-01-01

    Testing a single hardware unit of an accelerator control system often requires the setup of a program with graphical user interface. Developing a dedicated application for a specific hardware unit test could be time consuming and the application may become obsolete after the unit tests. This paper documents a methodology for quick design and setup of an interface focused on performing unit tests of accelerator equipment with minimum programming work. The method has three components. The first is a generic accelerator device object (ADO) manager which can be used to setup, store, and log testing controls parameters for any unit testing system. The second involves the design of a TAPE (Tool for Automated Procedure Execution) sequence file that specifies and implements all te testing and control logic. The sting third is the design of a PET (parameter editing tool) page that provides the unit tester with all the necessary control parameters required for testing. This approach has been used for testing the horizontal plane of the Stochastic Cooling Motion Control System at RHIC.

  18. Automotive RF immunity test set-up analysis

    NARCIS (Netherlands)

    Coenen, M.J.; Pues, H.; Bousquet, T.; Gillon, R.; Gielen, G.; Baric, A.

    2011-01-01

    Though the automotive RF emission and RF immunity requirements are highly justifiable, the application of those requirements in an non-intended manner leads to false conclusions and unnecessary redesigns for the electronics involved. When the test results become too dependent upon the test set-up

  19. Advanced Laboratory Setup for Testing Offshore Foundations

    DEFF Research Database (Denmark)

    Nielsen, Søren Dam; Ibsen, Lars Bo; Nielsen, Benjaminn Nordahl

    2016-01-01

    This paper describes a test setup for testing small-scale offshore foundations under realistic conditions of high pore-water pressure and high impact loads. The actuator, used for loading has enough capacity to apply sufficient force and displacement to achieve both drained and undrained failure ...

  20. A Test Setup for Quality Assurance of Front End Hybrids

    CERN Document Server

    Axer, Markus; Camps, Clemens; Commichau, Volker; Flügge, Günter; Franke, Torsten; Hangarter, Klaus; Ilgin, Can; Mnich, Joachim; Niehusmann, Jan; Poettgens, Michael; Schorn, Peter; Schulte, Reiner; Struczinski, Wolfgang

    2001-01-01

    The APV Readout Control (ARC) Test Setup is a compact, cost efficient test and diagnostic tool which is suited for full operation and characterisation of FE hybrids and Si-Detector modules. This note gives an overview of the construction and the features of the test facility. Based on the ARC setup and the experience gained with one prototype FE hybrid, possible quality assurance scenarios for short and long term tests of FE hybrids are also presented.

  1. Test Setup for Axially Loaded Piles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina

    The test setup for testing axially static and cyclic loaded piles in sand is described in the following. The purpose for the tests is to examine the tensile capacity of axially loaded piles in dense fully saturated sand. The pile dimensions are chosen to resemble full scale dimension of piles used...... in offshore pile foundations today....

  2. Cryogenic actuator testing for the SAFARI ground calibration setup

    Science.gov (United States)

    de Jonge, C.; Eggens, M.; Nieuwenhuizen, A. C. T.; Detrain, A.; Smit, H.; Dieleman, P.

    2012-09-01

    For the on-ground calibration setup of the SAFARI instrument cryogenic mechanisms are being developed at SRON Netherlands Institute for Space Research, including a filter wheel, XYZ-scanner and a flipmirror mechanism. Due to the extremely low background radiation requirement of the SAFARI instrument, all of these mechanisms will have to perform their work at 4.5 Kelvin and low-dissipative cryogenic actuators are required to drive these mechanisms. In this paper, the performance of stepper motors, piezoelectric actuators and brushless DC-motors as cryogenic actuators are compared. We tested stepper motor mechanical performance and electrical dissipation at 4K. The actuator requirements, test setup and test results are presented. Furthermore, design considerations and early performance tests of the flipmirror mechanism are discussed. This flipmirror features a 102 x 72 mm aluminum mirror that can be rotated 45°. A Phytron stepper motor with reduction gearbox has been chosen to drive the flipmirror. Testing showed that this motor has a dissipation of 49mW at 4K with a torque of 60Nmm at 100rpm. Thermal modeling of the flipmirror mechanism predicts that with proper thermal strapping the peak temperature of the flipmirror after a single action will be within the background level requirements of the SAFARI instrument. Early tests confirm this result. For low-duty cycle operations commercial stepper motors appear suitable as actuators for test equipment in the SAFARI on ground calibration setup.

  3. Development of a grinding-specific performance test set-up

    DEFF Research Database (Denmark)

    Olesen, C. G.; Larsen, B. H.; Andresen, E. L.

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding...... demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding...... and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding...

  4. Development of a grinding-specific performance test set-up.

    Science.gov (United States)

    Olesen, C G; Larsen, B H; Andresen, E L; de Zee, M

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding performance.

  5. MIMO OTA Testing in Small Multi-Probe Anechoic Chamber Setups

    DEFF Research Database (Denmark)

    Llorente, Ines Carton; Fan, Wei; Pedersen, Gert F.

    2016-01-01

    OTA testing of MIMO capable terminals is often performed in large anechoic chambers, where planar waves impinging the test area are assumed. Furthermore, reflections from the chamber, and probe coupling are often considered negligible due to the large dimensions of the chamber. This paper...... investigates the feasibility of reducing the physical dimension of 2D multi-probe anechoic chamber setups for MIMO OTA testing, with the purpose of reducing the cost and space of the setup. In the paper, a channel emulation algorithm and chamber compensation technique are proposed for MIMO OTA testing in small...... anechoic chambers. The performance deterioration in a small anechoic chamber, i.e., with a ring radius of 0.5 m, is demonstrated via simulations....

  6. Laboratory Test Setup for Cyclic Axially Loaded Piles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2017-01-01

    This paper presents a comprehensive description and the considerations regarding the design of a new laboratory test setup for testing cyclic axially loaded piles in sand. The test setup aims at analysing the effect of axial one-way cyclic loading on pile capacity and accumulated displacements....... Another aim was to test a large diameter pile segment with dimensions resembling full-scale piles to model the interface properties between pile and sand correctly. The pile segment was an open-ended steel pipe pile with a diameter of 0.5 m and a length of 1 m. The sand conditions resembled the dense sand...... determined from the API RP 2GEO standard and from the test results indicated over consolidation of the sand. Two initial one-way cyclic loading tests provided results of effects on pile capacity and accumulated displacements in agreement with other researchers’ test results....

  7. Automotive RF immunity test set-up analysis : why test results can't compare

    NARCIS (Netherlands)

    Coenen, Mart; Pues, H.; Bousquet, T.

    2011-01-01

    Though the automotive RF emission and RF immunity requirements are highly justifiable, the application of those requirements in an non-intended manner leads to false conclusions and unnecessary redesigns for the electronics involved. When the test results become too dependent upon the test set-up

  8. Medium Voltage Microgrid Test Setup and Procedures Implemented on a Real Pilot Project

    Directory of Open Access Journals (Sweden)

    Bruno Alberto Pacheco

    2018-01-01

    Full Text Available This paper presents various concepts related to the application of a microgrid pilot project in a residential condominium at Fortaleza / CE – Brazil, such as battery energy system, renewable and distributed generation, islanding recloser and all different units using interface based on power electronics. This papers main objective is to create information about microgrid operation and the interaction between its main equipment, such as power converters, utility energy distribution system and control units responsible for algorithms and changes in microgrids operation mode. This information is important for understanding the need for a test setup construction. To perform the test procedures, a temporary setup in a controlled environment within the microgrid is proposed. During the test periods, intentional power outages are required to evaluate the operating mode switching on each unit. The test setup described in this paper aims to mitigate the tests effects on other residential units inside the condominium.

  9. Benchmark test cases for evaluation of computer-based methods for detection of setup errors: realistic digitally reconstructed electronic portal images with known setup errors

    International Nuclear Information System (INIS)

    Fritsch, Daniel S.; Raghavan, Suraj; Boxwala, Aziz; Earnhart, Jon; Tracton, Gregg; Cullip, Timothy; Chaney, Edward L.

    1997-01-01

    Purpose: The purpose of this investigation was to develop methods and software for computing realistic digitally reconstructed electronic portal images with known setup errors for use as benchmark test cases for evaluation and intercomparison of computer-based methods for image matching and detecting setup errors in electronic portal images. Methods and Materials: An existing software tool for computing digitally reconstructed radiographs was modified to compute simulated megavoltage images. An interface was added to allow the user to specify which setup parameter(s) will contain computer-induced random and systematic errors in a reference beam created during virtual simulation. Other software features include options for adding random and structured noise, Gaussian blurring to simulate geometric unsharpness, histogram matching with a 'typical' electronic portal image, specifying individual preferences for the appearance of the 'gold standard' image, and specifying the number of images generated. The visible male computed tomography data set from the National Library of Medicine was used as the planning image. Results: Digitally reconstructed electronic portal images with known setup errors have been generated and used to evaluate our methods for automatic image matching and error detection. Any number of different sets of test cases can be generated to investigate setup errors involving selected setup parameters and anatomic volumes. This approach has proved to be invaluable for determination of error detection sensitivity under ideal (rigid body) conditions and for guiding further development of image matching and error detection methods. Example images have been successfully exported for similar use at other sites. Conclusions: Because absolute truth is known, digitally reconstructed electronic portal images with known setup errors are well suited for evaluation of computer-aided image matching and error detection methods. High-quality planning images, such as

  10. Setup of a testing environment for mission planning in mining

    NARCIS (Netherlands)

    Groenen, J.P.J.; Steinbuch, M.

    2013-01-01

    Mission planning algorithms for surface mining applications are difficult to test as a result of the large scale tasks. To validate these algorithms, a scaled setup is created where the mining excavator is mimicked by an industrial robot. This report discusses the development of a software

  11. An experimental set-up to test heatmoisture exchangers

    NARCIS (Netherlands)

    N. Ünal (N.); J.C. Pompe (Jan); W.P. Holland (Wim); I. Gultuna; P.E.M. Huygen; K. Jabaaij (K.); C. Ince (Can); B. Saygin (B.); H.A. Bruining (Hajo)

    1995-01-01

    textabstractObjectives: The purpose of this study was to build an experimental set-up to assess continuously the humidification, heating and resistance properties of heat-moisture exchangers (HMEs) under clinical conditions. Design: The experimental set-up consists of a patient model, measurement

  12. Set-up and Test Procedure for Suction Installation and Uninstallation of Bucket Foundation

    DEFF Research Database (Denmark)

    Koteras, Aleksandra Katarzyna

    This technical report describes the set-up and the test procedures for installation and uninstallation of medium-scale model of bucket foundation that can be performed in the geotechnical part of laboratory in Aalborg University. The installation of bucket foundation can be tested with the use of......) and loading frame used for those tests have been already used for axially static and cyclic loading of piles (Thomassen, 2015a) and for axially static and cyclic loading of bucket foundation (Vaitkunaite et al., 2015).......This technical report describes the set-up and the test procedures for installation and uninstallation of medium-scale model of bucket foundation that can be performed in the geotechnical part of laboratory in Aalborg University. The installation of bucket foundation can be tested with the use...... of suction under the bucket lid or by applying additional force through the hydraulic piston, forcing the bucket to penetrate into the soil. Tests for uninstallation are performed also with the use of water pressure, as a reverse process to the suction installation. Both installation and uninstallation tests...

  13. Predation of shore crabs (Carcinus maenas (L.)) and starfish (Asterias rubens L.) on blue mussel (Mytilus edulis L.) seed from wild sources and spat collectors

    NARCIS (Netherlands)

    Kamermans, P.; Blankendaal, M.; Perdon, J.

    2009-01-01

    In The Netherlands, several pilot projects are carried out on the use of spat collectors as an additional supply of seed for bottom culture of mussels (Mytilus edulis). The method proves to be successful in yielding substantial amounts of seed. One of the conditions for successful application of

  14. A test and calibration setup for mass-produced proportional chambers

    International Nuclear Information System (INIS)

    Burov, S.; Galaktionov, Yu.; Kamyshkov, Yu.

    1987-01-01

    The L3 experiment, presently being installed at (CERN) will use a 300 Hadron Calorimeter made of depleted uranium plates interleaved with about 8.000 proportional chambers. The review of experience in the use of gamma radioactivity of depleted uranium for the test of the chambers which are now being built at ITEP is given. The depleted uranium radioactivity and the response of a proportional chamber are discussed. A description of the test setup is given and a method to test the uniformity of the chamber response is discussed. Finally, a procedure for the L3 hadron calorimeter calibration in situ using uranium radioactivity is proposed

  15. Setup, tests and results for the ATLAS TileCal Read Out Driver production

    CERN Document Server

    Valero, Alberto; Castillo, V; Cuenca, C; Ferrer, A; Fullana, E; González, V; Higón, E; Munar, A; Poveda, J; Ruiz-Martínez, A; Salvachúa, B; Sanchís, E; Solans, C; Soret, J; Torres, J; Valls, J A

    2007-01-01

    In this paper we describe the performance and test results of the production of the 38 ATLAS TileCal Read Out Drivers (RODs). We first describe the basic hardware specifications and firmware functionality of the modules, the test-bench setup used for production and the test procedure to qualify the boards. We then finally show and discuss the performance results.

  16. An experimental set-up to test heat-moisture exchangers

    NARCIS (Netherlands)

    Unal, N.; Pompe, J. C.; Holland, W. P.; Gültuna, I.; Huygen, P. E.; Jabaaij, K.; Ince, C.; Saygin, B.; Bruining, H. A.

    1995-01-01

    The purpose of this study was to build an experimental set-up to assess continuously the humidification, heating and resistance properties of heat-moisture exchangers (HMEs) under clinical conditions. The experimental set-up consists of a patient model, measurement systems and a ventilator. Surgical

  17. Design and building of a new experimental setup for testing hydrogen storage materials

    Energy Technology Data Exchange (ETDEWEB)

    Andreasen, Anders

    2005-09-01

    For hydrogen to become the future energy carrier a suitable way of storing hydrogen is needed, especially if hydrogen is to be used in mobile applications such as cars. To test potential hydrogen storage materials with respect to capacity, kinetics and thermodynamics the Materials Research Department has a high pressure balance. However, the drawback of this equipment is, that in order to load samples, exposure towards air is inevitable. This has prompted the design and building of a new experimental setup with a detachable reactor allowing samples to be loaded under protective atmosphere. The purpose of this report is to serve as documentation of the new setup. (au)

  18. Research on mechanical and sensoric set-up for high strain rate testing of high performance fibers

    Science.gov (United States)

    Unger, R.; Schegner, P.; Nocke, A.; Cherif, C.

    2017-10-01

    Within this research project, the tensile behavior of high performance fibers, such as carbon fibers, is investigated under high velocity loads. This contribution (paper) focuses on the clamp set-up of two testing machines. Based on a kinematic model, weight optimized clamps are designed and evaluated. By analyzing the complex dynamic behavior of conventional high velocity testing machines, it has been shown that the impact typically exhibits an elastic characteristic. This leads to barely predictable breaking speeds and will not work at higher speeds when acceleration force exceeds material specifications. Therefore, a plastic impact behavior has to be achieved, even at lower testing speeds. This type of impact behavior at lower speeds can be realized by means of some minor test set-up adaptions.

  19. PC based manual and safety logic card test setup for 235 MWe PHWRs

    International Nuclear Information System (INIS)

    Chandgadkar, G.M.; Kohli, A.K.; Agarwal, R.G.; Chandra, Rajesh

    1992-01-01

    Fuel handling controls for 235 MWe PHWR make use of Manual and Logic cards (MLCs) for providing safety interlocks. These cards consist of various type of logic blocks. By connecting these logic blocks all the safety interlocks required for fuel handling controls have been provided. Previously trouble shooting of these cards was done by means of logic probe. Since the method was manual, it was laborious and time consuming. PC based test setup has overcome this drawback and detects the fault at the component level within few seconds. It also gives printout of status of faulty MLC cards. Here motherboard has been designed having slots for insertion of MLC cards. The input/output connection of these cards are coming to two 50 pin FRC connectors. PC communicates through 144 line digital input/output card with MLC card under test. Software is user friendly and outputs suitable input patterns to the card under test and checks for output pattern. It compares this output pattern with compare pattern and detects the fault and displays the symptoms. This system is currently in use at test facility for fuelling machine for 235 MWe PHWR reactor at Refuelling Technology Division, Hall-7. This test setup has been proposed for use at NAPP and future reactors. (author). 4 figs., 1 annexure

  20. Test setup for accelerated test of high power IGBT modules with online monitoring of Vce and Vf voltage during converter operation

    DEFF Research Database (Denmark)

    de Vega, Angel Ruiz; Ghimire, Pramod; Pedersen, Kristian Bonderup

    2014-01-01

    Several accelerated test methods exist in order to study the failures mechanisms of the high power IGBT modules like temperature cycling test or power cycles based on DC current pulses. The main drawback is that the test conditions do not represent the real performance and stress conditions...... of the device in real application. The hypothesis is that ageing of power modules closer to real environment including cooling system, full dc-link voltage and continuous PWM operation could lead to more accurate study of failure mechanism. A new type of test setup is proposed, which can create different real...... load conditions like in the field. Furthermore, collector-emitter voltage (Vce) has been used as indicator of the wear-out of the high power IGBT module. The innovative monitoring system implemented in the test setup is capable of measure the Vce and forward voltage of the antiparallel diode (Vf...

  1. PV inverter test setup for European efficiency, static and dynamic MPPT efficiency evaluation

    DEFF Research Database (Denmark)

    Sera, Dezso; Teodorescu, Remus; Valentini, Massimo

    2008-01-01

    This paper concerns the evaluation of performance of grid-connected PV inverters in terms of conversion efficiency, European efficiency, static and dynamic MPP efficiency. Semi-automated tests were performed in the PV laboratory of the Institute of Energy Technology at the Aalborg University...... (Denmark) on a commercial transformerless PV inverter. Thanks to the available experimental test setups, that provide the required high measuring accuracy, and the developed PV simulator, which is required for MPPT performance evaluation, PV Inverters can be pretested before being tested by accredited...

  2. Recent Advances on OTA Testing for 5G Antenna Systems in Multi-probe Anechoic Chamber Setups

    DEFF Research Database (Denmark)

    Fan, Wei; Pedersen, Gert F.; Kyösti, Pekka

    2018-01-01

    Over-the-air (OTA) testing is seen as an essential method for evaluating 5G antenna systems, since conventional cable testing are no longer applicable. In the paper, we discussed the similarities and discrepancies of OTA testing in the multiprobe anechoic chamber (MPAC) setups for 4G user equipment...

  3. Validity test of design calculations of a PGNAA setup

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Garwan, M.A.

    2004-01-01

    A rectangular moderator has been designed for the prompt gamma ray neutron activation analysis (PGNAA) setup at King Fahd University of Petroleum and Minerals (KFUPM) to analyze Portland cement samples. The design of the moderator assembly was obtained using Monte Carlo calculations. The design calculations of the new rectangular moderator of the KFUPM PGNAA setup have been verified experimentally through prompt gamma ray yield measurement as a function of the front moderator thickness. In this study the yield of the 3.54 and 4.94 MeV prompt gamma rays from silicon in a soil sample was measured as a function of thickness of the front moderator of the rectangular moderator. The experimental results were compared with the results of the Monte Carlo simulations. A good agreement has been achieved between the experimental results and the results of the calculations. The experimental results have provided useful information about the PGNAA setup performance, neutron moderation, and gamma ray attenuation in the PGNAA sample

  4. X-ray phase scanning setup for non-destructive testing using Talbot-Lau interferometer

    Science.gov (United States)

    Bachche, S.; Nonoguchi, M.; Kato, K.; Kageyama, M.; Koike, T.; Kuribayashi, M.; Momose, A.

    2016-09-01

    X-ray grating interferometry has a great potential for X-ray phase imaging over conventional X-ray absorption imaging which does not provide significant contrast for weakly absorbing objects and soft biological tissues. X-ray Talbot and Talbot-Lau interferometers which are composed of transmission gratings and measure the differential X-ray phase shifts have gained popularity because they operate with polychromatic beams. In X-ray radiography, especially for nondestructive testing in industrial applications, the feasibility of continuous sample scanning is not yet completely revealed. A scanning setup is frequently advantageous when compared to a direct 2D static image acquisition in terms of field of view, exposure time, illuminating radiation, etc. This paper demonstrates an efficient scanning setup for grating-based Xray phase imaging using laboratory-based X-ray source. An apparatus consisting of an X-ray source that emits X-rays vertically, optical gratings and a photon-counting detector was used with which continuously moving objects across the field of view as that of conveyor belt system can be imaged. The imaging performance of phase scanner was tested by scanning a long continuous moving sample at a speed of 5 mm/s and absorption, differential-phase and visibility images were generated by processing non-uniform moire movie with our specially designed phase measurement algorithm. A brief discussion on the feasibility of phase scanner with scanning setup approach including X-ray phase imaging performance is reported. The successful results suggest a breakthrough for scanning objects those are moving continuously on conveyor belt system non-destructively using the scheme of X-ray phase imaging.

  5. Mechanical design and fabrication of power feed cavity test setup

    International Nuclear Information System (INIS)

    Ghodke, S.R.; Dhavle, A.S.; Sharma, Vijay; Sarkar, Shreya; Kumar, Mahendra; Nayak, Susanta; Barnwal, Rajesh; Jayaprakash, D.; Mondal, J.; Nimje, V.T.; Mittal, K.C.; Gantayet, L.M.

    2013-01-01

    Power feed cavity set up consists of nine number of accelerating cavity and eight numbers of coupling cavity for testing of power feed cavity with coupling flange for 2856 MHz S band standing wave coupled cavity linac. When we are assembling the cavity and applying the pressure, its resonance frequency changes with applied pressure/load. After some critical pressure/load frequency change becomes negligible or zero. This set up will be used to find out assembly performance of power feed cavity and its coupler. Top four cavity or eight half cells as well as bottom four cavity or eight half cells will be brazed separately. Power feed cavity will be sandwiched between this two brazed cavity assemblies. This paper discuss about linear motion bush, linear motion rod, load cell, hydraulic actuator, power pack, stepper motor PLC control, jig boring, alignment, tolerances and assembly procedure for this test setup. (author)

  6. Magnet Test Setup of the CMS Tracker ready for installation

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    The pieces of the Tracker that will be operated in the forthcoming Magnet Test and Cosmic Challenge (MTCC) have been transported inside the dummy tracker support tube to the CMS experimental hall (Point 5, Cessy). The operation took place during the night of 12th May, covering the ~15km distance in about three hours. The transport was monitored for shocks, temperature and humidity with the help of the CERN TS-IC section. The Tracker setup comprises segments of the Tracker Inner Barrel (TIB), the Tracker Outer Barrel (TOB) and Tracker EndCaps (TEC) detectors. It represents roughly 1% of the final CMS Tracker. Installation into the solenoid is foreseen to take place on Wednesday 17th May.

  7. Community-acquired necrotizing pneumonia caused by methicillin-resistant Staphylococcus aureus ST30-SCCmecIVc-spat019-PVL positive in San Antonio de Areco, Argentina

    Directory of Open Access Journals (Sweden)

    Silvina Fernández

    2015-03-01

    Full Text Available Community-acquired methicillin-resistant Staphylococcus aureus is the first cause of skin and soft tissue infections, but can also produce severe diseases such as bacteremia, osteomyelitis and necrotizing pneumonia. Some S. aureus lineages have been described in cases of necrotizing pneumonia worldwide, usually in young, previously healthy patients. In this work, we describe a fatal case of necrotizing pneumonia due to community-acquired methicillin-resistant S. aureus clone ST30-SCCmecIVc-spat019-PVL positive in an immunocompetent adult patient.

  8. Performance tests of external moderators of a PGNAA setup

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Fazal-ur-Rehman,; Al-Jarallah, M.I.; Abu-Jarad, F.; Maslehuddin, M.

    2003-01-01

    Performance tests of external cylindrical moderators of an accelerator-based prompt gamma ray neutron activation analysis (PGNAA) setup have been carried out through thermal neutrons and prompt γ-ray yield measurements. The PGNAA setup is to be used for analysis of cement samples. This study was conducted to investigate the effects of geometry of cylindrical moderator on yield of thermal neutrons and prompt γ-rays for two different types of moderator assemblies. One of the moderators was to be used with a small sample and the other to be used with a large sample. Fast and thermal neutron yield was measured inside the sample volume as a function of the front moderator thickness as well as sample length. Neutron yield measurement was carried out at the King Fahd University of Petroleum and Minerals 350 keV pulsed beam accelerator using nuclear track detectors. The pulsed 200 keV deuteron beam with 5 ns pulse width and 31.25 kHz frequency was used to produce 2.8 MeV neutrons via D(d,n) reaction. Neutron yield measurements showed that the large sample moderator has a smaller yield of thermal neutrons as compared to the small sample moderator, which is in complete agreement with the results of Monte Carlo yield calculations of the thermal and fast neutrons from both the moderators. Finally, the prompt γ-ray yield from a Portland cement sample was measured using the two moderators and was compared with each other. As predicted by Monte Carlo simulations, in spite of a smaller yield of thermal neutrons, the large sample moderator has a higher yield of prompt γ-rays

  9. Performance tests of external moderators of a PGNAA setup

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. E-mail: aanaqvi@kfupm.edu.sa; Fazal-ur-Rehman,; Al-Jarallah, M.I.; Abu-Jarad, F.; Maslehuddin, M

    2003-01-01

    Performance tests of external cylindrical moderators of an accelerator-based prompt gamma ray neutron activation analysis (PGNAA) setup have been carried out through thermal neutrons and prompt {gamma}-ray yield measurements. The PGNAA setup is to be used for analysis of cement samples. This study was conducted to investigate the effects of geometry of cylindrical moderator on yield of thermal neutrons and prompt {gamma}-rays for two different types of moderator assemblies. One of the moderators was to be used with a small sample and the other to be used with a large sample. Fast and thermal neutron yield was measured inside the sample volume as a function of the front moderator thickness as well as sample length. Neutron yield measurement was carried out at the King Fahd University of Petroleum and Minerals 350 keV pulsed beam accelerator using nuclear track detectors. The pulsed 200 keV deuteron beam with 5 ns pulse width and 31.25 kHz frequency was used to produce 2.8 MeV neutrons via D(d,n) reaction. Neutron yield measurements showed that the large sample moderator has a smaller yield of thermal neutrons as compared to the small sample moderator, which is in complete agreement with the results of Monte Carlo yield calculations of the thermal and fast neutrons from both the moderators. Finally, the prompt {gamma}-ray yield from a Portland cement sample was measured using the two moderators and was compared with each other. As predicted by Monte Carlo simulations, in spite of a smaller yield of thermal neutrons, the large sample moderator has a higher yield of prompt {gamma}-rays.

  10. Improved Precision and Efficiency of a Modified ORG0020 Dynamic Respiration Test Setup for Compost Stability Assessment

    Directory of Open Access Journals (Sweden)

    Diana Guillen Ferrari

    2017-12-01

    Full Text Available The ORG0020 dynamic respiration test is effective at distinguishing source segregated organic waste derived composts across a wide range of stabilities when compared to other standard tests; however, using the original diaphragm pump and manifold setup, the test is affected by variability in flow rate with time and across sample replicate vessels. Here, we demonstrate the use of a multichannel peristaltic pump to deliver a more consistent air flow to individual vessels. Using finished and unfinished industry compost samples from different sites with varying stabilities, we provide evidence of greater precision of the modified setup compared to the original. Furthermore, the reduced need for air flow adjustment resulted in improved running cost efficiency with less labour demand. Analysis of compost sample oxygen demand supports the current test air flow rate of 25–75 mL min−1, although the improved air flow control will enable future narrowing of the acceptable range for better inter-laboratory performance.

  11. A setup to perform X-ray irradiation tests on scintillating fibres for the SciFi project

    CERN Document Server

    Gavardi, Laura; Joram, Christian; Kristic, Robert

    2017-01-01

    An X-ray setup has been installed at CERN. The setup will serve for quality assurance purposes related to the acceptance of $11'000~ \\text{km}$ of scintillating plastic fibres for the SciFi detector of LHCb. The X-ray tube has a tungsten target and can be powered up to 60kV, 30mA. The setup is intended to monitor the relative radiation response of the different fibre batches. The dose rate absorbed by the fibre under test can be tuned, adjusting the settings of the X-ray tube and adding aluminium filters of different thicknesses. When operating the X-ray tube without filters at a high voltage of $40\\rm \\,kV$ and an anode current of $30\\rm \\,mA$, the dose rate is about $23\\rm \\,Gy/min$. The maximum dose of about $35\\rm \\,kGy$ expected in the SciFi Tracker can be thus reached in about $1\\rm \\,day$.

  12. Digital setup for Doppler broadening spectroscopy

    International Nuclear Information System (INIS)

    Cizek, J; Vlcek, M; Prochazka, I

    2011-01-01

    New digital spectrometer for measurement of the Doppler shift of annihilation photons was developed and tested in this work. Digital spectrometer uses a fast 12-bit digitizer for direct sampling of signals from HPGe detectors. Analysis of sampled waveforms is performed off-line in software. Performance of the new digital setup was compared with its traditional analogue counterpart. Superior energy resolution was achieved in the digital setup. Moreover, the digital setup allows for a better control of the shape of detector signals. This enables to eliminate undesired signals damaged by pile-up effects or by ballistic deficit.

  13. Experimental Setups for Single Event Effect Studies

    OpenAIRE

    N. H. Medina; V. A. P. Aguiar; N. Added; F. Aguirre; E. L. A. Macchione; S. G. Alberton; M. A. G. Silveira; J. Benfica; F. Vargas; B. Porcher

    2016-01-01

    Experimental setups are being prepared to test and to qualify electronic devices regarding their tolerance to Single Event Effect (SEE). A multiple test setup and a new beam line developed especially for SEE studies at the São Paulo 8 UD Pelletron accelerator were prepared. This accelerator produces proton beams and heavy ion beams up to 107Ag. A Super conducting Linear accelerator, which is under construction, may fulfill all of the European Space Agency requirements to qualify electronic...

  14. Characterization of n-heptane as a single component Diesel surrogate fuel. EHPC test set-up implementation

    Energy Technology Data Exchange (ETDEWEB)

    Meijer, M.

    2010-06-15

    The availability of accurately measured fuel properties, during an injection event under engine relevant conditions is critical within the surrogate fuel approach. There is a need to perform in-house measurements in order to validate developed and new models. A well defined and accurately measured data-set will facilitate on-going work for sophisticated engine related in-cylinder combustion modeling. In this work pure n-heptane fuel is used as a single component surrogate fuel and is studied in a high-pressure constant volume optical test set-up. N-heptane is often used as a single component surrogate diesel fuel since it has a comparable Cetane number as European diesel. Detailed chemical-kinetic mechanisms for low-, intermediate-, and high-temperature n-heptane oxidation are available and several models exist that have sufficiently reduced dimensionality (number of species and reactions) to enable their use in CFD (Computational Fluid Mechanics) simulations. This report discusses the route and implementation to perform such an accurate and relevant n-heptane measurement series. The aim is to combine the efforts of earlier presented EHPC (Eindhoven High Pressure Cell) related work and new approaches, into the proposed surrogate fuel measurement series. The following aspects, related to the applied constant volume combustion chamber set-up, are studied and implemented: Extending the operating ranges towards relevant engine conditions; Study the accuracy and sensitivities of the different measurement steps; Implementing different optical diagnostic principles; and Implement a standardized and robust post processing routine. The different optical diagnostic principles used in this work are: high-speed Schlieren, Mie scattering and beginnings are made to implement a simultaneous LII LIF (Laser Induced Incandescence - Laser Induced Fluorescence) set-up using a new ICCD (Intensified Charge Coupled Device) camera with dual imaging feature. Combining the different

  15. Developing a reproducible non-line-of-sight experimental setup for testing wireless medical device coexistence utilizing ZigBee.

    Science.gov (United States)

    LaSorte, Nickolas J; Rajab, Samer A; Refai, Hazem H

    2012-11-01

    The integration of heterogeneous wireless technologies is believed to aid revolutionary healthcare delivery in hospitals and residential care. Wireless medical device coexistence is a growing concern given the ubiquity of wireless technology. In spite of this, a consensus standard that addresses risks associated with wireless heterogeneous networks has not been adopted. This paper serves as a starting point by recommending a practice for assessing the coexistence of a wireless medical device in a non-line-of-sight environment utilizing 802.15.4 in a practical, versatile, and reproducible test setup. This paper provides an extensive survey of other coexistence studies concerning 802.15.4 and 802.11 and reports on the authors' coexistence testing inside and outside an anechoic chamber. Results are compared against a non-line-of-sight test setup. Findings relative to co-channel and adjacent channel interference were consistent with results reported in the literature.

  16. Explaining perceived oral texture of starch-based custard desserts from standard and novel instrumental tests

    NARCIS (Netherlands)

    Wijk, R.A.de; Prinz, J.F.; Janssen, A.M.

    2006-01-01

    A number of in vitro and in vivo instrumental tests have been developed to reflect various aspects of the perceived oral texture of starch-based vanilla custard desserts. These tests include measurements of the food's infra-red reflectance (IRR), of the turbidity of spat-out rinse water, and of the

  17. Test of a cryogenic set-up for a 10 meter long liquid nitrogen cooled superconducting power cable

    DEFF Research Database (Denmark)

    Træholt, Chresten; Rasmussen, Carsten; Kühle (fratrådt), Anders Van Der Aa

    2000-01-01

    High temperature superconducting power cables may be cooled by a forced flow of sub-cooled liquid nitrogen. One way to do this is to circulate the liquid nitrogen (LN2) by means of a mechanical pump through the core of the cable and through a sub-cooler.Besides the cooling station, the cryogenics...... cable. We report on our experimental set-up for testing a 10 meter long high temperature superconducting cable with a critical current of 3.2 kA at 77K. The set-up consists of a custom designed cable end termination, current lead, coolant feed-through, liquid nitrogen closed loop circulation system...

  18. The experimental setup of a large field operational test for cooperative driving vehicles at the A270

    NARCIS (Netherlands)

    Broek, T.H.A. van den; Netten, B.D.; Hoedemaeker, M.; Ploeg, J.

    2010-01-01

    In this paper, a large field operational test (FOT) for cooperative driving systems, which take place on a public highway, is discussed. The experimental setup consist of a specific driver support system, which is closely related to cooperative adaptive cruise control (CACC) systems. Instead of

  19. Accuracy in tangential breast treatment set-up

    International Nuclear Information System (INIS)

    Tienhoven, G. van; Lanson, J.H.; Crabeels, D.; Heukelom, S.; Mijnheer, B.J.

    1991-01-01

    To test accuracy and reproducibility of tangential breast treatment set-up used in The Netherlands Cancer Institute, a portal imaging study was performed in 12 patients treated for early stage breast cancer. With an on-line electronic portal imaging device (EPID) images were obtained of each patient in several fractions and compared with simulator films and with each other. In 5 patients multiple images (on the average 7) per fraction were obtained to evaluate set-up variations due to respiratory movement. The central lung distance (CLD) and other set-up parameters varied within 1 fraction about 1mm (1SD). The average variation of these parameters between various fractions was about 2 mm (1SD). The differences between simulator and treatment set-up over all patients and all fractions was on the average 2-3mm for the central beam edge to skin distance and CLD. It can be concluded that the tangential breast treatment set-up is very stable and reproducible and that respiration does not have a significant influence on treatment volume. EPID appears to be an adequate tool for studies of treatment set-up accuracy like this. (author). 35 refs.; 2 figs.; 3 tabs

  20. Community-acquired necrotizing pneumonia caused by methicillin-resistant Staphylococcus aureus ST30-SCCmecIVc-spat019-PVL positive in San Antonio de Areco, Argentina.

    Science.gov (United States)

    Fernandez, Silvina; Murzicato, Sofía; Sandoval, Orlando; Fernández-Canigia, Liliana; Mollerach, Marta

    2015-01-01

    Community-acquired methicillin-resistant Staphylococcus aureus is the first cause of skin and soft tissue infections, but can also produce severe diseases such as bacteremia, osteomyelitis and necrotizing pneumonia. Some S. aureus lineages have been described in cases of necrotizing pneumonia worldwide, usually in young, previously healthy patients. In this work, we describe a fatal case of necrotizing pneumonia due to community-acquired methicillin-resistant S. aureus clone ST30-SCCmecIVc-spat019-PVL positive in an immunocompetent adult patient. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. TEST BEAM COORDINATION: The 2004 Test Beam Calorimetry set-up in H8

    CERN Multimedia

    Aleksa, M; Di Girolamo, B; Ferrari, C; Giugni, D; Santoni, C; Wingerter, I

    A new table has been designed, built and finally mounted to position the LAr cryostat in front of the Tilecal modules. The new table has been connected to the existing Tilecal table to be able to move the full set-up along eta values between 0 and 1.2. The table has been conceived by D. Giugni (INFN Milano and now CERN PH) and modeled by G. Braga (INFN Milano) in spring-summer 2003. The realization of the table has been done by an Italian firm (MatecImpianti, Fenegrò, Como) under the supervision of S. Coelli (INFN Milano) starting August 2003. Figure 1 shows the table assembled at the firm (left). Figure 1: The Tilecal-LAr table: in Fenegro (left) and at CERN (right). In November 2003 the table has been delivered to CERN and put in temporary storage to be assembled after the preparation of the Tilecal zone. In February 2004 two technicians from the firm and the team of technician coordinated by C. Ferrari (CERN AB/ATB), assembled, tested and commissioned the table under the supervision of S. Coelli...

  2. Multiple sample setup for testing the hydrothermal stability of adsorbents in thermal energy storage applications

    International Nuclear Information System (INIS)

    Fischer, Fabian; Laevemann, Eberhard

    2015-01-01

    Thermal energy storage based on adsorption and desorption of water on an adsorbent can achieve high energy storage densities. Many adsorbents lose adsorption capacity when operated under unfavourable hydrothermal conditions during adsorption and desorption. The stability of an adsorbent against stressing hydrothermal conditions is a key issue for its usability in adsorption thermal energy storage. We built an experimental setup that simultaneously controls the hydrothermal conditions of 16 samples arranged in a matrix of four temperatures and four water vapour pressures. This setup allows the testing of potential adsorbents between temperatures of 50 °C and 350 °C and water vapour pressures of up to 32 kPa. A measurement procedure that allows the detection of the hydrothermal stability of an adsorbent after defined time spans has been designed. We verified the functionality of the multiple sample measurements with a microporous adsorbent, a zeolite NaMSX. The hydrothermal stability of this zeolite is tested by water uptake measurements. A standard deviation lower than 1% of the 16 samples for detecting the hydrothermal stability enables setting different conditions in each sample cell. Further, we compared the water uptake measurements by measuring their adsorption isotherms with the volumetric device BELSORP Aqua 3 from Bel Japan. (paper)

  3. Setup planning for machining

    CERN Document Server

    Hazarika, Manjuri

    2015-01-01

    Professionals as well as researchers can benefit from this comprehensive introduction into the topic of setup planning, which reflects the latest state of research and gives hands-on examples. Starting with a brief but thorough introduction, this book explains the significance of setup planning in process planning and includes a reflection on its external constraints. Step-by-step the different phases of setup planning are outlined and traditional as well as modern approaches, such as fuzzy logic based setup planning, on the solution of setup planning problems are presented. Three detailed examples of applications provide a clear and accessible insight into the up-to-date techniques and various approaches in setup planning.

  4. Characterization of textile electrodes and conductors using standardized measurement setups

    International Nuclear Information System (INIS)

    Beckmann, L; Neuhaus, C; Medrano, G; Walter, M; Leonhardt, S; Jungbecker, N; Gries, T

    2010-01-01

    Textile electrodes and conductors are being developed and used in different monitoring scenarios, such as ECG or bioimpedance spectroscopy measurements. Compared to standard materials, conductive textile materials offer improved wearing comfort and enable long-term measurements. Unfortunately, the development and investigation of such materials often suffers from the non-reproducibility of the test scenarios. For example, the materials are generally tested on human skin which is difficult since the properties of human skin differ for each person and can change within hours. This study presents two test setups which offer reproducible measurement procedures for the systematic analysis of textile electrodes and conductors. The electrode test setup was designed with a special skin dummy which allows investigation of not only the electrical properties of textile electrodes but also the contact behavior between electrode and skin. Using both test setups, eight textile electrodes and five textile conductors were analyzed and compared

  5. Wall heat transfer coefficient in a molten salt bubble column: testing the experimental setup

    CSIR Research Space (South Africa)

    Skosana, PJ

    2014-10-01

    Full Text Available reactors that are highly exothermic or endothermic. This paper presents the design and operation of experimental setup used for measurement of the heat transfer coefficient in molten salt media. The experimental setup was operated with tap water, heat...

  6. The spectral imaging facility: Setup characterization

    Energy Technology Data Exchange (ETDEWEB)

    De Angelis, Simone, E-mail: simone.deangelis@iaps.inaf.it; De Sanctis, Maria Cristina; Manzari, Paola Olga [Institute for Space Astrophysics and Planetology, INAF-IAPS, Via Fosso del Cavaliere, 100, 00133 Rome (Italy); Ammannito, Eleonora [Institute for Space Astrophysics and Planetology, INAF-IAPS, Via Fosso del Cavaliere, 100, 00133 Rome (Italy); Department of Earth, Planetary and Space Sciences, University of California, Los Angeles, Los Angeles, California 90095-1567 (United States); Di Iorio, Tatiana [ENEA, UTMEA-TER, Rome (Italy); Liberati, Fabrizio [Opto Service SrL, Campagnano di Roma (RM) (Italy); Tarchi, Fabio; Dami, Michele; Olivieri, Monica; Pompei, Carlo [Selex ES, Campi Bisenzio (Italy); Mugnuolo, Raffaele [Italian Space Agency, ASI, Spatial Geodesy Center, Matera (Italy)

    2015-09-15

    The SPectral IMager (SPIM) facility is a laboratory visible infrared spectrometer developed to support space borne observations of rocky bodies of the solar system. Currently, this laboratory setup is used to support the DAWN mission, which is in its journey towards the asteroid 1-Ceres, and to support the 2018 Exo-Mars mission in the spectral investigation of the Martian subsurface. The main part of this setup is an imaging spectrometer that is a spare of the DAWN visible infrared spectrometer. The spectrometer has been assembled and calibrated at Selex ES and then installed in the facility developed at the INAF-IAPS laboratory in Rome. The goal of SPIM is to collect data to build spectral libraries for the interpretation of the space borne and in situ hyperspectral measurements of planetary materials. Given its very high spatial resolution combined with the imaging capability, this instrument can also help in the detailed study of minerals and rocks. In this paper, the instrument setup is first described, and then a series of test measurements, aimed to the characterization of the main subsystems, are reported. In particular, laboratory tests have been performed concerning (i) the radiation sources, (ii) the reference targets, and (iii) linearity of detector response; the instrumental imaging artifacts have also been investigated.

  7. Leadership set-up

    DEFF Research Database (Denmark)

    Thude, Bettina Ravnborg; Stenager, Egon; von Plessen, Christian

    2018-01-01

    . Findings: The study found that the leadership set-up did not have any clear influence on interdisciplinary cooperation, as all wards had a high degree of interdisciplinary cooperation independent of which leadership set-up they had. Instead, the authors found a relation between leadership set-up and leader...... could influence legitimacy. Originality/value: The study shows that leadership set-up is not the predominant factor that creates interdisciplinary cooperation; but rather, leader legitimacy also should be considered. Additionally, the study shows that leader legitimacy can be difficult to establish...... and that it cannot be taken for granted. This is something chief executive officers should bear in mind when they plan and implement new leadership structures. Therefore, it would also be useful to look more closely at how to achieve legitimacy in cases where the leader is from a different profession to the staff....

  8. An edge over diagnostic setup

    Directory of Open Access Journals (Sweden)

    Sridhar Kannan

    2017-01-01

    Full Text Available Diagnostic setup proposed by H.D. Kingsley serves as a practical aid in treatment planning and diagnosis. These setups have some inherent shortcomings. A simple technique of duplication of the setups in dental stone can solve problems encountered before as well as provide many other advantages over the conventional procedure. The diagnostic setup is prepared by the conventional method [Figure 1]. An alginate impression is then taken of the setups and poured in dental stone to obtain the derived treatment model [Figure 2]. The same setup can now be further modified for alternate lines of treatment. Subsequently models could then be obtained as required [Figure 3].

  9. Experimental Setup for Reflood Quench of Accident Tolerant Fuel Claddings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chan; Lee, Kwan Geun; In, Wang Kee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The concept of accident tolerant fuel (ATF) is a solution to suppress the hydrogen generation in loss of coolant accident (LOCA) situation without safety injection, which was the critical incident in the severe accident in the Fukushima. The changes in fuel and cladding materials may cause a significant difference in reactor performance in long term operation. Properties in terms of material science and engineering have been tested and showed promising results. However, numerous tests are still required to ensure the design performance and safety. Thermal hydraulic tests including boiling and quenching are partly confirmed, but not yet complete. We have been establishing the experimental setup to confirm the properties in the terms of thermal hydraulics. Design considerations and preliminary tests are introduced in this paper. An experimental setup to test thermal hydraulic characteristics of new ATF claddings are established and tested. The W heater set inside the cladding is working properly, exceeding 690 W/m linear power with thermocouples and insulating ceramic sheaths inside. The coolant injection control was also working in good conditions. The setup is about to complete and going to simulate quenching behavior of the ATF in the LOCA situation.

  10. Qualified measurement setup of polarization extinction ratio for Panda PMF with LC/UPC connector

    Science.gov (United States)

    Thongdaeng, Rutsuda; Worasucheep, Duang-rudee; Ngiwprom, Adisak

    2018-03-01

    Polarization Extinction Ratio (PER) is one of the key parameters for Polarization Maintaining Fiber (PMF) connector. Based on our previous studies, the bending radius of fiber greater than 1.5 cm will not affect the insertion loss of PMF [1]. Moreover, the measured PER of Panda PMF with LC/UPC connectors is more stable when that PMF is coiled around a hot rod with a minimum of 3-cm in diameter at 75°C temperature [2]. Hence, the hot rod with less constrained 6-cm in diameter at constant 75°C was selected for this PER measurement. Two PER setups were verified and compared for measuring LC/UPC PMF connectors. The Polarized Laser Source (PLS) at 1550 nm wavelength and PER meter from OZ Optics were used in both setups, in which the measured connector was connected to PLS at 0° angle while the other end was connected to PER meter. In order to qualify our setups, the percentage of Repeatability and Reproducibility (%R&R) were tested and calculated. In each setup, the PER measurement was repeated 3 trials by 3 appraisers using 10 LC/UPC PMF connectors (5 LC/UPC PMF patchcords with 3.5+/-0.5 meters in length) in random order. The 1st setup, PMF was coiled at a larger 20-cm diameter for 3 to 5 loops and left in room temperature during the test. The 2nd setup, PMF was coiled around a hot rod at constant 75°C with 6-cm diameter for 8 to 10 loops for at least 5 minutes before testing. There are 3 ranges of %R&R acceptation guide line: <10% is acceptable, between 10% - 30% is marginal, and <30% is unacceptable. According to our results, the %R&R of the 1st PER test setup was 16.2% as marginality, and the 2nd PER test setup was 8.9% as acceptance. Thus, providing the better repeatability and reproducibility, this 2nd PER test setup having PMF coiled around a hot rod at constant 75°C with 6-cm diameter was selected for our next study of the impact of hot temperature on PER in LC/UPC PMF connector.

  11. Building and commissioning of a setup to study ageing phenomena in gaseous detectors

    International Nuclear Information System (INIS)

    Abuhoza, A.; Schmidt, H.R.; Biswas, S.; Frankenfeld, U.; Hehner, J.; Schmidt, C.J.

    2016-01-01

    In high-rate heavy-ion experiments, gaseous detectors encounter big challenges in terms of degradation of their performance due to a phenomenon called ageing. A setup for high precision ageing studies has been constructed and commissioned at the GSI detector laboratory. The setup as well as the gas system have been carefully optimized to reach a high sensitivity for ageing effects. Two different materials have been examined for their influence on gaseous detectors: RTV-3145 and Gerband 705. The details of the construction of the ageing test setup and the test results will be presented.

  12. Building and commissioning of a setup to study ageing phenomena in gaseous detectors

    Energy Technology Data Exchange (ETDEWEB)

    Abuhoza, A., E-mail: aabuhoza@kacst.edu.sa [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt 64291 (Germany); King Abdulaziz City for Science and Technology (KACST), Riyadh (Saudi Arabia); Goethe-Universität, Frankfurt (Germany); Schmidt, H.R. [Eberhard-Karls-Universität, Tübingen (Germany); Biswas, S. [School of Physical Sciences, National Institute of Science Education and Research, Jatni 752050 (India); Frankenfeld, U.; Hehner, J.; Schmidt, C.J. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt 64291 (Germany)

    2016-07-11

    In high-rate heavy-ion experiments, gaseous detectors encounter big challenges in terms of degradation of their performance due to a phenomenon called ageing. A setup for high precision ageing studies has been constructed and commissioned at the GSI detector laboratory. The setup as well as the gas system have been carefully optimized to reach a high sensitivity for ageing effects. Two different materials have been examined for their influence on gaseous detectors: RTV-3145 and Gerband 705. The details of the construction of the ageing test setup and the test results will be presented.

  13. Experimental set-up for advanced aeroelastic tests on sectional models

    Czech Academy of Sciences Publication Activity Database

    Král, Radomil; Pospíšil, Stanislav; Náprstek, Jiří

    2016-01-01

    Roč. 40, č. 1 (2016), s. 3-13 ISSN 0732-8818 R&D Projects: GA ČR GA103/09/0094; GA AV ČR IAA200710902; GA MŠk(CZ) ED1.1.00/02.0060 Institutional support: RVO:68378297 Keywords : bridge aeroelasticity * wind tunnel * experimental set-up * non- linear response Subject RIV: JM - Building Engineering Impact factor: 0.932, year: 2016 http://link.springer.com/article/10.1007%2Fs40799-015-0004-6

  14. A Full-size High Temperature Superconducting Coil Employed in a Wind Turbine Generator Set-up

    DEFF Research Database (Denmark)

    Song, Xiaowei (Andy); Mijatovic, Nenad; Kellers, Jürgen

    2016-01-01

    A full-size stationary experimental set-up, which is a pole pair segment of a 2 MW high temperature superconducting (HTS) wind turbine generator, has been built and tested under the HTS-GEN project in Denmark. The performance of the HTS coil is crucial to the set-up, and further to the development...... is tested in LN2 first, and then tested in the set-up so that the magnetic environment in a real generator is reflected. The experimental results are reported, followed by a finite element simulation and a discussion on the deviation of the results. The tested and estimated Ic in LN2 are 148 A and 143 A...

  15. 350 keV accelerator-based neutron transmission setup at KFUPM for hydrogen detection

    CERN Document Server

    Naqvi, A; Maslehuddin, M; Kidwai, S; Nassar, R

    2002-01-01

    An experimental setup has been developed to determine hydrogen contents of bulk samples using fast neutron transmission technique. Neutrons with 3 MeV energy were produced via D(d, n) reaction. The neutrons transmitted through the sample were detected by a NE213 scintillation detector. Preliminary tests of the setup were carried out using soil samples with different moisture contents. In addition to experimental study, Monte Carlo simulations were carried out to generate calibration curve of the experimental setup. Finally, experimental tests results were compared with the results of Monte Carlo simulations. A good agreement has been obtained between the simulation results and experimental results.

  16. Characterization of a neutron imaging setup at the INES facility

    Energy Technology Data Exchange (ETDEWEB)

    Durisi, E.A., E-mail: elisabettaalessandra.durisi@unito.it [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Visca, L. [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Albertin, F.; Brancaccio, R. [Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Corsi, J. [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Dughera, G. [Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Ferrarese, W. [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Giovagnoli, A.; Grassi, N. [Fondazione Centro per la Conservazione ed il Restauro dei Beni Culturali “La Venaria Reale”, Piazza della Repubblica, 10078 Venaria Reale, Torino (Italy); Grazzi, F. [Consiglio Nazionale delle Ricerche, Istituto dei Sistemi Complessi, Via Madonna del Piano 10, 50019 Sesto Fiorentino, Firenze (Italy); Lo Giudice, A.; Mila, G. [Università di Torino, Dipartimento di Fisica, Via Pietro Giuria 1, 10125 Torino (Italy); Istituto Nazionale di Fisica Nucleare—Sezione di Torino, Via Pietro Giuria 1, 10125 Torino (Italy); and others

    2013-10-21

    The Italian Neutron Experimental Station (INES) located at the ISIS pulsed neutron source (Didcot, United Kingdom) provides a thermal neutron beam mainly used for diffraction analysis. A neutron transmission imaging system was also developed for beam monitoring and for aligning the sample under investigation. Although the time-of-flight neutron diffraction is a consolidated technique, the neutron imaging setup is not yet completely characterized and optimized. In this paper the performance for neutron radiography and tomography at INES of two scintillator screens read out by two different commercial CCD cameras is compared in terms of linearity, signal-to-noise ratio, effective dynamic range and spatial resolution. In addition, the results of neutron radiographies and a tomography of metal alloy test structures are presented to better characterize the INES imaging capabilities of metal artifacts in the cultural heritage field. -- Highlights: A full characterization of the present INES imaging set-up was carried out. Two CCD cameras and two scintillators (ZnS/{sup 6}LiF) of different thicknesses were tested. Linearity, effective dynamic range and spatial resolution were determined. Radiographies of steep wedges were performed using the highest dynamic range setup. Tomography of a bronze cube was performed using the best spatial resolution setup.

  17. Characterization of a neutron imaging setup at the INES facility

    International Nuclear Information System (INIS)

    Durisi, E.A.; Visca, L.; Albertin, F.; Brancaccio, R.; Corsi, J.; Dughera, G.; Ferrarese, W.; Giovagnoli, A.; Grassi, N.; Grazzi, F.; Lo Giudice, A.; Mila, G.

    2013-01-01

    The Italian Neutron Experimental Station (INES) located at the ISIS pulsed neutron source (Didcot, United Kingdom) provides a thermal neutron beam mainly used for diffraction analysis. A neutron transmission imaging system was also developed for beam monitoring and for aligning the sample under investigation. Although the time-of-flight neutron diffraction is a consolidated technique, the neutron imaging setup is not yet completely characterized and optimized. In this paper the performance for neutron radiography and tomography at INES of two scintillator screens read out by two different commercial CCD cameras is compared in terms of linearity, signal-to-noise ratio, effective dynamic range and spatial resolution. In addition, the results of neutron radiographies and a tomography of metal alloy test structures are presented to better characterize the INES imaging capabilities of metal artifacts in the cultural heritage field. -- Highlights: A full characterization of the present INES imaging set-up was carried out. Two CCD cameras and two scintillators (ZnS/ 6 LiF) of different thicknesses were tested. Linearity, effective dynamic range and spatial resolution were determined. Radiographies of steep wedges were performed using the highest dynamic range setup. Tomography of a bronze cube was performed using the best spatial resolution setup

  18. Improved mortar setup technique

    CSIR Research Space (South Africa)

    De Villiers, D

    2008-10-01

    Full Text Available bearing sensor. This concept focuses directly on one of the most cumbersome aspects of a mortar set-up, namely the use of aiming posts. The prismatic mirror and bearing dials is described as well as the required setup procedures. The measurement...

  19. The virtual slice setup.

    Science.gov (United States)

    Lytton, William W; Neymotin, Samuel A; Hines, Michael L

    2008-06-30

    In an effort to design a simulation environment that is more similar to that of neurophysiology, we introduce a virtual slice setup in the NEURON simulator. The virtual slice setup runs continuously and permits parameter changes, including changes to synaptic weights and time course and to intrinsic cell properties. The virtual slice setup permits shocks to be applied at chosen locations and activity to be sampled intra- or extracellularly from chosen locations. By default, a summed population display is shown during a run to indicate the level of activity and no states are saved. Simulations can run for hours of model time, therefore it is not practical to save all of the state variables. These, in any case, are primarily of interest at discrete times when experiments are being run: the simulation can be stopped momentarily at such times to save activity patterns. The virtual slice setup maintains an automated notebook showing shocks and parameter changes as well as user comments. We demonstrate how interaction with a continuously running simulation encourages experimental prototyping and can suggest additional dynamical features such as ligand wash-in and wash-out-alternatives to typical instantaneous parameter change. The virtual slice setup currently uses event-driven cells and runs at approximately 2 min/h on a laptop.

  20. Setup uncertainties in linear accelerator based stereotactic radiosurgery and a derivation of the corresponding setup margin for treatment planning.

    Science.gov (United States)

    Zhang, Mutian; Zhang, Qinghui; Gan, Hua; Li, Sicong; Zhou, Su-min

    2016-02-01

    In the present study, clinical stereotactic radiosurgery (SRS) setup uncertainties from image-guidance data are analyzed, and the corresponding setup margin is estimated for treatment planning purposes. Patients undergoing single-fraction SRS at our institution were localized using invasive head ring or non-invasive thermoplastic masks. Setup discrepancies were obtained from an in-room x-ray patient position monitoring system. Post treatment re-planning using the measured setup errors was performed in order to estimate the individual target margins sufficient to compensate for the actual setup errors. The formula of setup margin for a general SRS patient population was derived by proposing a correlation between the three-dimensional setup error and the required minimal margin. Setup errors of 104 brain lesions were analyzed, in which 81 lesions were treated using an invasive head ring, and 23 were treated using non-invasive masks. In the mask cases with image guidance, the translational setup uncertainties achieved the same level as those in the head ring cases. Re-planning results showed that the margins for individual patients could be smaller than the clinical three-dimensional setup errors. The derivation of setup margin adequate to address the patient setup errors was demonstrated by using the arbitrary planning goal of treating 95% of the lesions with sufficient doses. With image guidance, the patient setup accuracy of mask cases can be comparable to that of invasive head rings. The SRS setup margin can be derived for a patient population with the proposed margin formula to compensate for the institution-specific setup errors. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. Setup Analysis: Combining SMED with Other Tools

    Directory of Open Access Journals (Sweden)

    Stadnicka Dorota

    2015-02-01

    Full Text Available The purpose of this paper is to propose the methodology for the setup analysis, which can be implemented mainly in small and medium enterprises which are not convinced to implement the setups development. The methodology was developed after the research which determined the problem. Companies still have difficulties with a long setup time. Many of them do nothing to decrease this time. A long setup is not a sufficient reason for companies to undertake any actions towards the setup time reduction. To encourage companies to implement SMED it is essential to make some analyses of changeovers in order to discover problems. The methodology proposed can really encourage the management to take a decision about the SMED implementation, and that was verified in a production company. The setup analysis methodology is made up of seven steps. Four of them concern a setups analysis in a chosen area of a company, such as a work stand which is a bottleneck with many setups. The goal is to convince the management to begin actions concerning the setups improvement. The last three steps are related to a certain setup and, there, the goal is to reduce a setup time and the risk of problems which can appear during the setup. In this paper, the tools such as SMED, Pareto analysis, statistical analysis, FMEA and other were used.

  2. Very high stability systems: LMJ target alignment system and MTG imager test setup

    Science.gov (United States)

    Compain, Eric; Maquet, Philippe; Kunc, Thierry; Marque, Julien; Lauer-Solelhac, Maxime; Delage, Laurent; Lanternier, Catherine

    2015-09-01

    Most of space instruments and research facilities require test equipment with demanding opto-mechanical stability. In some specific cases, when the stability performance directly drives the final performance of the scientific mission and when feasibility is questionable, specific methods must be implemented for the associated technical risk management. In present paper, we will present our heritage in terms of methodology, design, test and the associated results for two specific systems : the SOPAC-POS and the MOTA, generating new references for future developments. From a performance point of view, we will emphasis on following key parameters : design symmetry, thermal load management, and material and structural choices. From a method point of view the difficulties arise first during design, from the strong coupling between the thermal, mechanical and optical performance models, and then during testing, from the difficulty of conceiving test setup having appropriate performance level. We will present how these limitations have been overcome. SOPAC-POS is the target alignment system of the LMJ, Laser Mega Joule, the French inertial confinement fusion research center. Its stability has been demonstrated by tests in 2014 after 10 years of research and development activities, achieving 1μm stability @ 6m during one hour periods. MOTA is an Optical Ground Support Equipment aiming at qualifying by tests the Flexible Combined Imager (FCI). FCI is an instrument for the meteorological satellite MTG-I, a program of and funded by the European Space Agency and under prime contractorship of Thales Alenia Space. Optimized design will allow to get better than 0.2 μrad stability for one hour periods, as required for MTF measurement.

  3. Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins

    International Nuclear Information System (INIS)

    Rudat, Volker; Hammoud, Mohamed; Pillay, Yogin; Alaradi, Abdul Aziz; Mohamed, Adel; Altuwaijri, Saleh

    2011-01-01

    The purpose of the study was to evaluate the patient set-up error of different anatomical sites, to estimate the effect of different frequencies of online verifications on the patient set-up accuracy, and to calculate margins to accommodate for the patient set-up error (ICRU set-up margin, SM). Alignment data of 148 patients treated with inversed planned intensity modulated radiotherapy (IMRT) or three-dimensional conformal radiotherapy (3D-CRT) of the head and neck (n = 31), chest (n = 72), abdomen (n = 15), and pelvis (n = 30) were evaluated. The patient set-up accuracy was assessed using orthogonal megavoltage electronic portal images of 2328 fractions of 173 planning target volumes (PTV). In 25 patients, two PTVs were analyzed where the PTVs were located in different anatomical sites and treated in two different radiotherapy courses. The patient set-up error and the corresponding SM were retrospectively determined assuming no online verification, online verification once a week and online verification every other day. The SM could be effectively reduced with increasing frequency of online verifications. However, a significant frequency of relevant set-up errors remained even after online verification every other day. For example, residual set-up errors larger than 5 mm were observed on average in 18% to 27% of all fractions of patients treated in the chest, abdomen and pelvis, and in 10% of fractions of patients treated in the head and neck after online verification every other day. In patients where high set-up accuracy is desired, daily online verification is highly recommended

  4. High-resolution continuous-flow analysis setup for water isotopic measurement from ice cores using laser spectroscopy

    Science.gov (United States)

    Emanuelsson, B. D.; Baisden, W. T.; Bertler, N. A. N.; Keller, E. D.; Gkinis, V.

    2015-07-01

    Here we present an experimental setup for water stable isotope (δ18O and δD) continuous-flow measurements and provide metrics defining the performance of the setup during a major ice core measurement campaign (Roosevelt Island Climate Evolution; RICE). We also use the metrics to compare alternate systems. Our setup is the first continuous-flow laser spectroscopy system that is using off-axis integrated cavity output spectroscopy (OA-ICOS; analyzer manufactured by Los Gatos Research, LGR) in combination with an evaporation unit to continuously analyze water samples from an ice core. A Water Vapor Isotope Standard Source (WVISS) calibration unit, manufactured by LGR, was modified to (1) enable measurements on several water standards, (2) increase the temporal resolution by reducing the response time and (3) reduce the influence from memory effects. While this setup was designed for the continuous-flow analysis (CFA) of ice cores, it can also continuously analyze other liquid or vapor sources. The custom setups provide a shorter response time (~ 54 and 18 s for 2013 and 2014 setup, respectively) compared to the original WVISS unit (~ 62 s), which is an improvement in measurement resolution. Another improvement compared to the original WVISS is that the custom setups have a reduced memory effect. Stability tests comparing the custom and WVISS setups were performed and Allan deviations (σAllan) were calculated to determine precision at different averaging times. For the custom 2013 setup the precision after integration times of 103 s is 0.060 and 0.070 ‰ for δ18O and δD, respectively. The corresponding σAllan values for the custom 2014 setup are 0.030, 0.060 and 0.043 ‰ for δ18O, δD and δ17O, respectively. For the WVISS setup the precision is 0.035, 0.070 and 0.042 ‰ after 103 s for δ18O, δD and δ17O, respectively. Both the custom setups and WVISS setup are influenced by instrumental drift with δ18O being more drift sensitive than δD. The

  5. Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins

    Directory of Open Access Journals (Sweden)

    Mohamed Adel

    2011-08-01

    Full Text Available Abstract Purpose The purpose of the study was to evaluate the patient set-up error of different anatomical sites, to estimate the effect of different frequencies of online verifications on the patient set-up accuracy, and to calculate margins to accommodate for the patient set-up error (ICRU set-up margin, SM. Methods and materials Alignment data of 148 patients treated with inversed planned intensity modulated radiotherapy (IMRT or three-dimensional conformal radiotherapy (3D-CRT of the head and neck (n = 31, chest (n = 72, abdomen (n = 15, and pelvis (n = 30 were evaluated. The patient set-up accuracy was assessed using orthogonal megavoltage electronic portal images of 2328 fractions of 173 planning target volumes (PTV. In 25 patients, two PTVs were analyzed where the PTVs were located in different anatomical sites and treated in two different radiotherapy courses. The patient set-up error and the corresponding SM were retrospectively determined assuming no online verification, online verification once a week and online verification every other day. Results The SM could be effectively reduced with increasing frequency of online verifications. However, a significant frequency of relevant set-up errors remained even after online verification every other day. For example, residual set-up errors larger than 5 mm were observed on average in 18% to 27% of all fractions of patients treated in the chest, abdomen and pelvis, and in 10% of fractions of patients treated in the head and neck after online verification every other day. Conclusion In patients where high set-up accuracy is desired, daily online verification is highly recommended.

  6. Stress testing of electrically active FlexMEAs with simultaneous electrical recording in fluidic environment: Introduction of a new measurement setup

    Science.gov (United States)

    Westerhausen, Markus; Martin, Tanja; Kappel, Marcel; Hofmann, Boris

    2018-02-01

    We present a measurement setup consisting of two fluid-filled pressure chambers to mimic the mechanical stress likely to that of small body movements on biomedical flexible micro-electrode arrays for the analysis of various degradation mechanisms. Our main goal was the simulation of micro-motions in fluid conditions, while maintaining an electric access to the device. These micro-motions would be likely to those occurring in the human body caused by the intracranial pressure in magnitudes of 7-25 mmHg, which translates to a fluid pressure of 9-33 mbar. Furthermore, severe mechanical stress can be administered to the samples under the previously mentioned environment. Therefore, a flexible, polyimide-based sample with various metal test structures was fabricated and analyzed in the presented measurement setup. A comparison of the elongation of the sample's surface as a function of the applied hydrostatic pressure is given with computer simulations.

  7. ASD FieldSpec Calibration Setup and Techniques

    Science.gov (United States)

    Olive, Dan

    2001-01-01

    This paper describes the Analytical Spectral Devices (ASD) Fieldspec Calibration Setup and Techniques. The topics include: 1) ASD Fieldspec FR Spectroradiometer; 2) Components of Calibration; 3) Equipment list; 4) Spectral Setup; 5) Spectral Calibration; 6) Radiometric and Linearity Setup; 7) Radiometric setup; 8) Datadets Required; 9) Data files; and 10) Field of View Measurement. This paper is in viewgraph form.

  8. Estimating setup of driven piles into Louisiana clayey soils.

    Science.gov (United States)

    2010-11-15

    Two types of mathematical models for pile setup prediction, the Skov-Denver model and the newly developed rate-based model, have been established from all the dynamic and static testing data, including restrikes of the production piles, restrikes, st...

  9. Over-the-air Radiated Testing of Millimeter-Wave Beam-steerable Devices in a Cost-Effective Measurement Setup

    DEFF Research Database (Denmark)

    Fan, Wei; Kyösti, Pekka; Rumney, Moray

    2018-01-01

    antenna selection scheme is proposed. This setup is suitable for evaluation of beam-steerable devices, including both base station (BS) and user equipment (UE) devices. The requirements for the test system design are analyzed, including the measurement range, number of OTA antennas, number of active OTA...... conditions. In this article, radiated testing methods are reviewed, with a focus on their principle and applicability for beam steerable mmWave devices. To explore the spatial sparsity of mmWave channel profiles, a cost-effective simplified 3D sectored multi-probe anechoic chamber (MPAC) system with an OTA......With the severe spectrum congestion of sub-6GHz cellular systems, large-scale antenna systems in the millimeter-wave (mmWave) bands can potentially meet the high data rate envisioned for fifth generation (5G) communications. Performance evaluation of antenna systems is an essential step...

  10. Server farms with setup costs

    NARCIS (Netherlands)

    Gandhi, A.; Harchol-Balter, M.; Adan, I.J.B.F.

    2010-01-01

    In this paper we consider server farms with a setup cost. This model is common in manufacturing systems and data centers, where there is a cost to turn servers on. Setup costs always take the form of a time delay, and sometimes there is additionally a power penalty, as in the case of data centers.

  11. A laboratory test setup for in situ measurements of the dielectric properties of catalyst powder samples under reaction conditions by microwave cavity perturbation: set up and initial tests.

    Science.gov (United States)

    Dietrich, Markus; Rauch, Dieter; Porch, Adrian; Moos, Ralf

    2014-09-10

    The catalytic behavior of zeolite catalysts for the ammonia-based selective catalytic reduction (SCR) of nitrogen oxides (NOX) depends strongly on the type of zeolite material. An essential precondition for SCR is a previous ammonia gas adsorption that occurs on acidic sites of the zeolite. In order to understand and develop SCR active materials, it is crucial to know the amount of sorbed ammonia under reaction conditions. To support classical temperature-programmed desorption (TPD) experiments, a correlation of the dielectric properties with the catalytic properties and the ammonia sorption under reaction conditions appears promising. In this work, a laboratory test setup, which enables direct measurements of the dielectric properties of catalytic powder samples under a defined gas atmosphere and temperature by microwave cavity perturbation, has been developed. Based on previous investigations and computational simulations, a resonator cavity and a heating system were designed, installed and characterized. The resonator cavity is designed to operate in its TM010 mode at 1.2 GHz. The first measurement of the ammonia loading of an H-ZSM-5 zeolite confirmed the operating performance of the test setup at constant temperatures of up to 300 °C. It showed how both real and imaginary parts of the relative complex permittivity are strongly correlated with the mass of stored ammonia.

  12. The TwinEBIS setup: Machine description

    Energy Technology Data Exchange (ETDEWEB)

    Breitenfeldt, M. [CERN, Geneva 23 CH-1211 (Switzerland); Mertzig, R. [CERN, Geneva 23 CH-1211 (Switzerland); Technische Universität Dresden, 01069 Dresden (Germany); Pitters, J. [CERN, Geneva 23 CH-1211 (Switzerland); Technische Universität Wien, 1040 Vienna (Austria); Shornikov, A. [CERN, Geneva 23 CH-1211 (Switzerland); GANIL, Bd. Becquerel, BP 55027, 14076 Caen Cedex 05 (France); Wenander, F., E-mail: fredrik.wenander@cern.ch [CERN, Geneva 23 CH-1211 (Switzerland)

    2017-06-01

    TwinEBIS is an Electron Beam Ion Source (EBIS) recently made operational at CERN. The device is similar in construction to the REXEBIS charge breeder operating at the ISOLDE facility. After relocation of the solenoid from the Manne Siegbahn Laboratory (MSL) Stockholm, TwinEBIS was commissioned at CERN and serves as a test bench dedicated to manipulation of low-energy highly charged ions. In this paper we give an overview of the setup and present advanced numerical simulations of the electron optics. In addition, the alignment procedure of the solenoid magnetic field is described and measurement results are presented. Results from cathode investigations, electron beam tests and ion extraction modulation are presented in a follow-up paper.

  13. High-temperature metallography setup

    International Nuclear Information System (INIS)

    Blumenfeld, M.; Shmarjahu, D.; Elfassy, S.

    1979-06-01

    A high-temperature metallography setup is presented. In this setup the observation of processes such as that of copper recrystallization was made possible, and the structure of metals such as uranium could be revealed. A brief historical review of part of the research works that have been done with the help of high temperature metallographical observation technique since the beginning of this century is included. Detailed description of metallographical specimen preparation technique and theoretical criteria based on the rate of evaporation of materials present on the polished surface of the specimens are given

  14. Set-up of a pre-test mock-up experiment in preparation for the HCPB Breeder Unit mock-up experimental campaign

    Energy Technology Data Exchange (ETDEWEB)

    Hernández, F., E-mail: francisco.hernandez@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (INR) (Germany); Kolb, M. [Karlsruhe Institute of Technology (KIT), Institute for Applied Materials (IAM-WPT) (Germany); Ilić, M.; Kunze, A. [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (INR) (Germany); Németh, J. [KFKI Research Institute for Particle and Nuclear Physics (Hungary); Weth, A. von der [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (INR) (Germany)

    2013-10-15

    Highlights: ► As preparation for the HCPB-TBM Breeder Unit out-of-pile testing campaign, a pre-test experiment (PREMUX) has been prepared and described. ► A new heater system based on a wire heater matrix has been developed for imitating the neutronic volumetric heating and it is compared with the conventional plate heaters. ► The test section is described and preliminary thermal results with the available models are presented and are to be benchmarked with PREMUX. ► The PREMUX integration in the air cooling loop L-STAR/LL in the Karlsruhe Institute for Technology is shown and future steps are discussed. -- Abstract: The complexity of the experimental set-up for testing a full-scaled Breeder Unit (BU) mock-up for the European Helium Cooled Pebble Bed Test Blanket Module (HCPB-TBM) has motivated to build a pre-test mock-up experiment (PREMUX) consisting of a slice of the BU in the Li{sub 4}SiO{sub 4} region. This pre-test aims at verifying the feasibility of the methods to be used for the subsequent testing of the full-scaled BU mock-up. Key parameters needed for the modeling of the breeder material is also to be determined by the Hot Wire Method (HWM). The modeling tools for the thermo-mechanics of the pebble beds and for the mock-up structure are to be calibrated and validated as well. This paper presents the setting-up of PREMUX in the L-STAR/LL facility at the Karlsruhe Institute of Technology. A key requirement of the experiments is to mimic the neutronic volumetric heating. A new heater concept is discussed and compared to several conventional heater configurations with respect to the estimated temperature distribution in the pebble beds. The design and integration of the thermocouple system in the heater matrix and pebble beds is also described, as well as other key aspects of the mock-up (dimensions, layout, cooling system, purge gas line, boundary conditions and integration in the test facility). The adequacy of these methods for the full-scaled BU

  15. A setup for active fault diagnosis

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik

    2006-01-01

    A setup for active fault diagnosis (AFD) of parametric faults in dynamic systems is formulated in this paper. It is shown that it is possible to use the same setup for both open loop systems, closed loop systems based on a nominal feedback controller as well as for closed loop systems based...... on a reconfigured feedback controller. This will make the proposed AFD approach very useful in connection with fault tolerant control (FTC). The setup will make it possible to let the fault diagnosis part of the fault tolerant controller remain unchanged after a change in the feedback controller. The setup for AFD...... is based on the YJBK (after Youla, Jabr, Bongiorno and Kucera) parameterization of all stabilizing feedback controllers and the dual YJBK parameterization. It is shown that the AFD is based directly on the dual YJBK transfer function matrix. This matrix will be named the fault signature matrix when...

  16. Flight Tests of a 0.13-Scale Model of the Convair XFY-1 Vertically Rising Airplane in a Setup Simulating that Proposed for Captive-Flight Tests in a Hangar, TED No. NACA DE 368

    Science.gov (United States)

    Lovell, Powell M., Jr.

    1953-01-01

    An experimental investigation has been conducted to determine the dynamic stability and control characteristics of a 0.13-scale free-flight model of the Convair XFY-1 airplane in test setups representing the setup proposed for use in the first flight tests of the full-scale airplane in the Moffett Field airship hangar. The investigation was conducted in two parts: first, tests with the model flying freely in an enclosure simulating the hangar, and second, tests with the model partially restrained by an overhead line attached to the propeller spinner and ground lines attached to the wing and tail tips. The results of the tests indicated that the airplane can be flown without difficulty in the Moffett Field airship hangar if it does not approach too close to the hangar walls. If it does approach too close to the walls, the recirculation of the propeller slipstream might cause sudden trim changes which would make smooth flight difficult for the pilot to accomplish. It appeared that the tethering system proposed by Convair could provide generally satisfactory restraint of large-amplitude motions caused by control failure or pilot error without interfering with normal flying or causing any serious instability or violent jerking motions as the tethering lines restrained the model.

  17. High precision neutron interferometer setup S18b

    International Nuclear Information System (INIS)

    Hasegawa, Y.; Lemmel, H.

    2011-01-01

    The present setup at S18 is a multi purpose instrument. It is used for both interferometry and a Bonse-Hart camera for USANS (Ultra Small Angle Neutron Scattering) spectroscopy with wide range tunability of wavelength. Some recent measurements demand higher stability of the instrument, which made us to propose a new setup dedicated particularly for neutron interferometer experiments requiring high phase stability. To keep both options available, we suggest building the new setup in addition to the old one. By extending the space of the present setup by 1.5 m to the upstream, both setups can be accommodated side by side. (authors)

  18. Combined UHV/high-pressure catalysis setup for depth-resolved near-surface spectroscopic characterization and catalytic testing of model catalysts

    International Nuclear Information System (INIS)

    Mayr, Lukas; Klötzer, Bernhard; Penner, Simon; Rameshan, Raffael; Rameshan, Christoph

    2014-01-01

    An ultra-high vacuum (UHV) setup for “real” and “inverse” model catalyst preparation, depth-resolved near-surface spectroscopic characterization, and quantification of catalytic activity and selectivity under technologically relevant conditions is described. Due to the all-quartz reactor attached directly to the UHV-chamber, transfer of the catalyst for in situ testing without intermediate contact to the ambient is possible. The design of the UHV-compatible re-circulating batch reactor setup allows the study of reaction kinetics under close to technically relevant catalytic conditions up to 1273 K without contact to metallic surfaces except those of the catalyst itself. With the attached differentially pumped exchangeable evaporators and the quartz-microbalance thickness monitoring equipment, a reproducible, versatile, and standardised sample preparation is possible. For three-dimensional near-surface sample characterization, the system is equipped with a hemispherical analyser for X-ray photoelectron spectroscopy (XPS), electron-beam or X-ray-excited Auger-electron spectroscopy, and low-energy ion scattering measurements. Due the dedicated geometry of the X-ray gun (54.7°, “magic angle”) and the rotatable sample holder, depth analysis by angle-resolved XPS measurements can be performed. Thus, by the combination of characterisation methods with different information depths, a detailed three-dimensional picture of the electronic and geometric structure of the model catalyst can be obtained. To demonstrate the capability of the described system, comparative results for depth-resolved sample characterization and catalytic testing in methanol steam reforming on PdGa and PdZn near-surface intermetallic phases are shown

  19. Combined UHV/high-pressure catalysis setup for depth-resolved near-surface spectroscopic characterization and catalytic testing of model catalysts

    Science.gov (United States)

    Mayr, Lukas; Rameshan, Raffael; Klötzer, Bernhard; Penner, Simon; Rameshan, Christoph

    2014-05-01

    An ultra-high vacuum (UHV) setup for "real" and "inverse" model catalyst preparation, depth-resolved near-surface spectroscopic characterization, and quantification of catalytic activity and selectivity under technologically relevant conditions is described. Due to the all-quartz reactor attached directly to the UHV-chamber, transfer of the catalyst for in situ testing without intermediate contact to the ambient is possible. The design of the UHV-compatible re-circulating batch reactor setup allows the study of reaction kinetics under close to technically relevant catalytic conditions up to 1273 K without contact to metallic surfaces except those of the catalyst itself. With the attached differentially pumped exchangeable evaporators and the quartz-microbalance thickness monitoring equipment, a reproducible, versatile, and standardised sample preparation is possible. For three-dimensional near-surface sample characterization, the system is equipped with a hemispherical analyser for X-ray photoelectron spectroscopy (XPS), electron-beam or X-ray-excited Auger-electron spectroscopy, and low-energy ion scattering measurements. Due the dedicated geometry of the X-ray gun (54.7°, "magic angle") and the rotatable sample holder, depth analysis by angle-resolved XPS measurements can be performed. Thus, by the combination of characterisation methods with different information depths, a detailed three-dimensional picture of the electronic and geometric structure of the model catalyst can be obtained. To demonstrate the capability of the described system, comparative results for depth-resolved sample characterization and catalytic testing in methanol steam reforming on PdGa and PdZn near-surface intermetallic phases are shown.

  20. A laboratory experimental setup for photo-absorption studies using synchrotron radiation

    CERN Document Server

    Shastri, A; Saraswati, P; Sunanda, K

    2002-01-01

    The photophysics beamline, which is being installed at the 450 MeV Synchrotron Radiation Source (SRS), Indus-l, is a medium resolution beamline useful for a variety of experiments in the VUV region viz. 500-2000 A. One of the major applications of this beamline is gas-phase photo-absorption studies. An experimental set up to be used for these experiments was designed, developed and tested in our laboratory. The setup consists of a high vacuum absorption cell, 1/4 m monochromator and detection system. For the purpose of testing, xenon and tungsten continuum sources were used and absorption spectra were recorded in the UV region. This setup was used to record the absorption spectrum of a few molecules like acetone, ammonia, benzene, formaldehyde and acetaldehyde in order to evaluate the performance of the experimental system which will subsequently be used with the photophysics beamline. Details of the design, fabrication and testing of the absorption cell and experimental procedures are presented in this repor...

  1. Points in the set-up of tests for fMRI. Toward the delineation of language-competent areas in clinical practice

    International Nuclear Information System (INIS)

    Takashima, Hisaharu; Ejima, Mitsuhiro; Takeyama, Mamoru; Yamaguchi, Masami; Sato, Yoshino

    2001-01-01

    This hospital has performed fMRI of language-competent areas of the brain to identify the language-dominant hemisphere and obtain the configuration of the focus in the language-dominant side of the brain. Until now, signals have been detected in only two of fifteen patients who were diagnosed by language tests of a last-syllable word chain. In the present experiment, we tried to have subjects select the type of test. The result was that changes in signals were detected in eight of ten patients. Although the set-up of tests for fMRI is said to hold significant value, clear-cut studies to back this up have rarely been seen. Because clinical medicine treats patients who have difficulty in communication or suffer from aphasia, it is important to take into consideration individual variations and to set up a test suitable for, or achievable by, these individuals. The present method enabled us to avoid failure in examination caused by unsuccessful tests. (author)

  2. Points in the set-up of tests for fMRI. Toward the delineation of language-competent areas in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Takashima, Hisaharu; Ejima, Mitsuhiro; Takeyama, Mamoru; Yamaguchi, Masami; Sato, Yoshino [Tokyo Women' s Medical Coll. (Japan). Hospital

    2001-06-01

    This hospital has performed fMRI of language-competent areas of the brain to identify the language-dominant hemisphere and obtain the configuration of the focus in the language-dominant side of the brain. Until now, signals have been detected in only two of fifteen patients who were diagnosed by language tests of a last-syllable word chain. In the present experiment, we tried to have subjects select the type of test. The result was that changes in signals were detected in eight of ten patients. Although the set-up of tests for fMRI is said to hold significant value, clear-cut studies to back this up have rarely been seen. Because clinical medicine treats patients who have difficulty in communication or suffer from aphasia, it is important to take into consideration individual variations and to set up a test suitable for, or achievable by, these individuals. The present method enabled us to avoid failure in examination caused by unsuccessful tests. (author)

  3. Evaluating Speed Enforcement Field Set-Ups Used by Regional Police in Belgium: An Analysis of Speed Outcome Indicators

    Directory of Open Access Journals (Sweden)

    Brenda Wilmots

    2016-12-01

    Full Text Available In this paper the results from a field experiment (conducted in 2012 are presented, in which 3 regional police units in the Flemish region of Belgium each tested a particular combination of a speed control (with mobile radar in an anonymous car with communicative signage. The goal of this paper was to scientifically evaluate frequently used field set-ups. The following set-ups were tested in one week: (1 police unit 1: speed control with and without a static feedback sign placed after the control; (2 police unit 2: speed control with and without a digital feedback sign placed after the control; (3 police unit 3: speed display followed by a second speed display further along the road section. During certain time frames, speed control took place in between both signs. All tested field set-ups generated significant reductions in the speed level. Studying the effect of the different variations for each set-up reveals that the effect of the speed control is generally larger in combination with the signage alongside the road. After the period during which the police activities took place, speed levels again reached their initial level. Based on the before–after analysis, only in police area 2 was a small ‘time halo-effect’ found. To generalize results from this pilot study, repetition of tested set-ups in the field is recommended as well as testing on a larger scale.

  4. A Laboratory Test Setup for in Situ Measurements of the Dielectric Properties of Catalyst Powder Samples under Reaction Conditions by Microwave Cavity Perturbation: Set up and Initial Tests

    Directory of Open Access Journals (Sweden)

    Markus Dietrich

    2014-09-01

    Full Text Available The catalytic behavior of zeolite catalysts for the ammonia-based selective catalytic reduction (SCR of nitrogen oxides (NOX depends strongly on the type of zeolite material. An essential precondition for SCR is a previous ammonia gas adsorption that occurs on acidic sites of the zeolite. In order to understand and develop SCR active materials, it is crucial to know the amount of sorbed ammonia under reaction conditions. To support classical temperature-programmed desorption (TPD experiments, a correlation of the dielectric properties with the catalytic properties and the ammonia sorption under reaction conditions appears promising. In this work, a laboratory test setup, which enables direct measurements of the dielectric properties of catalytic powder samples under a defined gas atmosphere and temperature by microwave cavity perturbation, has been developed. Based on previous investigations and computational simulations, a resonator cavity and a heating system were designed, installed and characterized. The resonator cavity is designed to operate in its TM010 mode at 1.2 GHz. The first measurement of the ammonia loading of an H-ZSM-5 zeolite confirmed the operating performance of the test setup at constant temperatures of up to 300 °C. It showed how both real and imaginary parts of the relative complex permittivity are strongly correlated with the mass of stored ammonia.

  5. Influence of random setup error on dose distribution

    International Nuclear Information System (INIS)

    Zhai Zhenyu

    2008-01-01

    Objective: To investigate the influence of random setup error on dose distribution in radiotherapy and determine the margin from ITV to PTV. Methods: A random sample approach was used to simulate the fields position in target coordinate system. Cumulative effect of random setup error was the sum of dose distributions of all individual treatment fractions. Study of 100 cumulative effects might get shift sizes of 90% dose point position. Margins from ITV to PTV caused by random setup error were chosen by 95% probability. Spearman's correlation was used to analyze the influence of each factor. Results: The average shift sizes of 90% dose point position was 0.62, 1.84, 3.13, 4.78, 6.34 and 8.03 mm if random setup error was 1,2,3,4,5 and 6 mm,respectively. Univariate analysis showed the size of margin was associated only by the size of random setup error. Conclusions: Margin of ITV to PTV is 1.2 times random setup error for head-and-neck cancer and 1.5 times for thoracic and abdominal cancer. Field size, energy and target depth, unlike random setup error, have no relation with the size of the margin. (authors)

  6. Inventory control with multiple setup costs

    NARCIS (Netherlands)

    Alp, O.; Huh, W.T.; Tan, T.

    2014-01-01

    We consider an infinite-horizon, periodic-review, single-item production/inventory system with random demand and backordering, where multiple setups are allowed in any period and a separate fixed cost is associated for each setup. Contrary to the majority of the literature on this topic, we do not

  7. Split scheduling with uniform setup times.

    NARCIS (Netherlands)

    F. Schalekamp; R.A. Sitters (René); S.L. van der Ster; L. Stougie (Leen); V. Verdugo; A. van Zuylen

    2015-01-01

    htmlabstractWe study a scheduling problem in which jobs may be split into parts, where the parts of a split job may be processed simultaneously on more than one machine. Each part of a job requires a setup time, however, on the machine where the job part is processed. During setup, a

  8. Split Scheduling with Uniform Setup Times

    NARCIS (Netherlands)

    Schalekamp, F.; Sitters, R.A.; van der Ster, S.L.; Stougie, L.; Verdugo, V.; van Zuylen, A.

    2015-01-01

    We study a scheduling problem in which jobs may be split into parts, where the parts of a split job may be processed simultaneously on more than one machine. Each part of a job requires a setup time, however, on the machine where the job part is processed. During setup, a machine cannot process or

  9. Delft Dashboard: a quick setup tool for coastal and estuarine models

    Science.gov (United States)

    Nederhoff, C., III; Van Dongeren, A.; Van Ormondt, M.; Veeramony, J.

    2016-02-01

    We developed easy-to-use Delft DashBoard (DDB) software for the rapid set-up of coastal and estuarine hydrodynamic and basic morphological numerical models. In the "Model Maker" toolbox, users have the capability to set-up Delft3D models, in a minimal amount of time (in the order of a hour), for any location in the world. DDB draws upon public internet data sources of bathymetry and tidesto construct the model. With additional toolboxes, these models can be forced with parameterized hurricane wind fields, uplift of the sea surface due to tsunamis nested in publically available ocean models and forced with meteo data (wind speed, pressure, temperature) In this presentation we will show the skill of a model which is setup with Delft Dashboard and compare it to well-calibrated benchmark models. These latter models have been set-up using detailed input data and boundary conditions. We have tested the functionality of Delft DashBoard and evaluate the performance and robustness of the DDB model system on a variety of cases, ranging from a coastal to basin models. Furthermore, we have performed a sensitivity study to investigate the most critical physical and numerical processes. The software can benefit operational modellers, as well as scientists and consultants.

  10. An experimental set-up to measure Light Yield of Scintillating Fibres

    CERN Document Server

    Alfieri, C; Joram, C; Kenzie, M W

    2015-01-01

    In the context of the LHCb SciFi Tracker project, an experimental set up was designed and built to provide reliable and reproducible measurements of the light yield of scintillating fibres. This document describes the principle and technical realisation of the set-up. A few examples illustrate the operation and data analysis. In the first implementation of the set-up a photomultiplier tube with bialkali photocathode was used for the reading of the light from the fibres under test. In order to measure also green emitting fibres, the photomultiplier was replaced in January 2016 by a SiPM with higher sensitivity and larger spectral coverage1.

  11. A simple experimental setup for magneto-dielectric measurements

    Energy Technology Data Exchange (ETDEWEB)

    Manimuthu, P.; Shanker, N. Praveen; Kumar, K. Saravana; Venkateswaran, C., E-mail: cvunom@hotmail.com

    2014-09-01

    The increasing demand for the multiferroic materials calls for the need of an experimental setup that will facilitate magneto-dielectric coupling measurements. A connector setup designed makes it possible to measure and analyze the dielectric properties of the material under the influence of a magnetic field. The salient feature of this setup is in its incorporation with the already existing experimental facilities.

  12. A simple experimental setup for magneto-dielectric measurements

    International Nuclear Information System (INIS)

    Manimuthu, P.; Shanker, N. Praveen; Kumar, K. Saravana; Venkateswaran, C.

    2014-01-01

    The increasing demand for the multiferroic materials calls for the need of an experimental setup that will facilitate magneto-dielectric coupling measurements. A connector setup designed makes it possible to measure and analyze the dielectric properties of the material under the influence of a magnetic field. The salient feature of this setup is in its incorporation with the already existing experimental facilities

  13. ESTERR-PRO: A Setup Verification Software System Using Electronic Portal Imaging

    Directory of Open Access Journals (Sweden)

    Pantelis A. Asvestas

    2007-01-01

    Full Text Available The purpose of the paper is to present and evaluate the performance of a new software-based registration system for patient setup verification, during radiotherapy, using electronic portal images. The estimation of setup errors, using the proposed system, can be accomplished by means of two alternate registration methods. (a The portal image of the current fraction of the treatment is registered directly with the reference image (digitally reconstructed radiograph (DRR or simulator image using a modified manual technique. (b The portal image of the current fraction of the treatment is registered with the portal image of the first fraction of the treatment (reference portal image by applying a nearly automated technique based on self-organizing maps, whereas the reference portal has already been registered with a DRR or a simulator image. The proposed system was tested on phantom data and on data from six patients. The root mean square error (RMSE of the setup estimates was 0.8±0.3 (mean value ± standard deviation for the phantom data and 0.3±0.3 for the patient data, respectively, by applying the two methodologies. Furthermore, statistical analysis by means of the Wilcoxon nonparametric signed test showed that the results that were obtained by the two methods did not differ significantly (P value >0.05.

  14. Multiparametric Experiments and Multiparametric Setups for Metering Explosive Eruptions

    Science.gov (United States)

    Taddeucci, J.; Scarlato, P.; Del Bello, E.

    2016-12-01

    Explosive eruptions are multifaceted processes best studied by integrating a variety of observational perspectives. This need marries well with the continuous stream of new means that technological progress provides to volcanologists to parameterize these eruptions. Since decades, new technologies have been tested and integrated approaches have been attempted during so-called multiparametric experiments, i.e., short field campaigns with many, different instruments (and scientists) targeting natural laboratory volcanoes. Recently, portable multiparametric setups have been developed, including a few, highly complementary instruments to be rapidly deployed at any erupting volcano. Multiparametric experiments and setups share most of their challenges, like technical issues, site logistics, and data processing and interpretation. Our FAMoUS (FAst MUltiparametric Setup) setup pivots around coupled, high-speed imaging (visible and thermal) and acoustic (infrasonic to audible) recording, plus occasional seismic recording and sample collection. FAMoUS provided new insights on pyroclasts ejection and settling and jet noise dynamics at volcanoes worldwide. In the last years we conducted a series of BAcIO (Broadband ACquisition and Imaging Operation) experiments at Stromboli (Italy). These hosted state-of-the-art and prototypal eruption-metering technologies, including: multiple high-speed high-definition cameras for 3-D imaging; combined visible-infrared-ultraviolet imaging; in-situ and remote gas measurements; UAV aerial surveys; Doppler radar, and microphone arrays. This combined approach provides new understandings of the fundamental controls of Strombolian-style activity, and allows for crucial cross-validation of instruments and techniques. Several documentary expeditions participated in the BAcIO, attesting its tremendous potential for public outreach. Finally, sharing field work promotes interdisciplinary discussions and cooperation like nothing in the world.

  15. Setup error in three-dimensional conformal radiotherapy for thoracic esophageal carcinoma

    International Nuclear Information System (INIS)

    Hong Jinsheng; Zhang Weijian; Chen Jinmei; Cai Chuanshu; Ke Chunlin; Chen Xiuying; Wu Bing; Guo Feibao

    2009-01-01

    Objective: To study the setup errors in three-dimensional conformal radiotherapy (3DCRT) for thoracic esophageal carcinoma using electronic portal imaging device(EPID) and calculate the margins from CTV to PTV. Methods: Forty-one patients with thoracic esophageal carcinoma who received 3DCRT were continuously enrolled into this study. The anterior and lateral electronic portal images (EPI) were aquired by EPID once a week. The setup errors were obtained through comparing the difference between EPI and digitally reconstructed radiographs (DRR). Then the setup margins from CTV to PTV were calculated. By using self paired design, 22 patients received definitive radiotherapy with different margins. Group A: the margins were 10 mm in all the three axes; Group B: the margins were aquired in this study. The difference were compared by Paired t-test or Wilcoxon signed-rank test. Results: The margins from CTV to PTV in x, y and z axes were 8.72 mm, 10.50 mm and 5.62 mm, respectively. Between the group A and group B, the difference of the maximum dose of the spinal cord was significant(4638.7 cGy ± 1449.6 cGy vs. 4310.2 cGy ± 1528.7 cGy; t=5.48, P=0.000), and the difference of NTCP for the spinal cord was also significant (4.82% ± 5.99% vs. 3.64% ± 4.70%; Z=-2.70, P=0.007). Conclusions: For patients with thoracic esophageal carcinoma who receive 3DCRT in author's department, the margins from CTV to PTV in x, y and z axes were 8.72 mm, 10.50 mm and 5.62 mm, respectively. The spinal cord could be better protected by using these setup margins than using 10 mm in each axis. (authors)

  16. Evaluating the performance of constructive heuristics for the blocking flow shop scheduling problem with setup times

    Directory of Open Access Journals (Sweden)

    Mauricio Iwama Takano

    2019-01-01

    Full Text Available This paper addresses the minimization of makespan for the permutation flow shop scheduling problem with blocking and sequence and machine dependent setup times, a problem not yet studied in previous studies. The 14 best known heuristics for the permutation flow shop problem with blocking and no setup times are pre-sented and then adapted to the problem in two different ways; resulting in 28 different heuristics. The heuristics are then compared using the Taillard database. As there is no other work that addresses the problem with blocking and sequence and ma-chine dependent setup times, a database for the setup times was created. The setup time value was uniformly distributed between 1% and 10%, 50%, 100% and 125% of the processing time value. Computational tests are then presented for each of the 28 heuristics, comparing the mean relative deviation of the makespan, the computational time and the percentage of successes of each method. Results show that the heuristics were capable of providing interesting results.

  17. Minimization of number of setups for mounting machines

    Energy Technology Data Exchange (ETDEWEB)

    Kolman, Pavel; Nchor, Dennis; Hampel, David [Department of Statistics and Operation Analysis, Faculty of Business and Economics, Mendel University in Brno, Zemědělská 1, 603 00 Brno (Czech Republic); Žák, Jaroslav [Institute of Technology and Business, Okružní 517/10, 370 01 České Budejovice (Czech Republic)

    2015-03-10

    The article deals with the problem of minimizing the number of setups for mounting SMT machines. SMT is a device used to assemble components on printed circuit boards (PCB) during the manufacturing of electronics. Each type of PCB has a different set of components, which are obligatory. Components are placed in the SMT tray. The problem consists in the fact that the total number of components used for all products is greater than the size of the tray. Therefore, every change of manufactured product requires a complete change of components in the tray (i.e., a setup change). Currently, the number of setups corresponds to the number of printed circuit board type. Any production change affects the change of setup and stops production on one shift. Many components occur in more products therefore the question arose as to how to deploy the products into groups so as to minimize the number of setups. This would result in a huge increase in efficiency of production.

  18. Setup uncertainties: consequences for multi-isocentre stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Ebert, M.A.; Harper, C.S.

    2000-01-01

    Full text: Beam data for use in dose calculations by planning systems is generally measured under static and controlled conditions. Yet, patient motion and setup uncertainties will effectively blur the resulting dose distributions leading to a discrepancy between planned and delivered dose distributions. This is particularly so for stereotactic radiotherapy where small well-defined fields are used. When multiple isocentres are used (possibly for larger irregular lesions), relative motion of isocentres due to setup variations may have deleterious effects on the intended radiation delivery. The influence of setup uncertainties was examined by performing a three-dimensional convolution of measured off-axis ratio (OAR) data with a Maxwellian distribution, with standard deviations representing several feasible levels of inaccuracy in patient setup. A sample of patient plans (predominantly multi-isocentre plans) were then considered using original (measured) OAR data, and then modified data in order to observe the resulting effect. The effect of systematic localisation error was also considered by examining resulting DVHs as isocentres were shifted by fixed amounts. In all cases considered, the maximum dose varied quite minimally with increase in setup error with the variation decreasing with increasing high-dose volume. The minimum dose however varied more significantly, and this has serious consequences for dose prescription as the minimum dose can be the controlling factor in treatment efficacy. For multi-isocentre plans, the degree of non-uniformity generated by setup error was not as significant as originally expected. This is in part due to the non-uniformity already present in such plans to begin with. Through incorporation of the effect of setup error into planning data, the influence of setup variations on dose distributions for multi-isocentre treatments has been determined. This influence should be considered when creating plans based on the level of spatial

  19. Influence of different test parameters on in vitro drug release from topical diclofenac formulations in a vertical diffusion cell setup.

    Science.gov (United States)

    Klein, S

    2013-07-01

    In the past decades, the vertical diffusion cell has emerged as a useful device for testing drug release of topical dosage forms. However, to date neither a general USP method nor formulation-related monographs have been published in international pharmacopoeia. The purpose of the present work was to examine the influence of different test parameters in a vertical diffusion cell setup on in vitro drug release from semi-solid preparations for cutaneous application. Diclofenac was selected as the model compound. Release experiments were performed in a 7 ml Microett vertical diffusion cell system. Various test parameters, including the media composition and pH, degassing, membrane material and pore size, stirring speed and stirrer type, were varied. Results obtained with different test parameter settings clearly indicate that both drug properties and instrumental details can have a huge impact on the outcome of in vitro diffusion/drug release studies with the vertical diffusion cell. Thus, the selection of adequate test parameters is crucial for the success of the release experiments and, as shown in the present study, optimal test parameters/conditions need to be established and validated on a case by case study.

  20. Assessing the ability of mechanistic volatilization models to simulate soil surface conditions: a study with the Volt'Air model.

    Science.gov (United States)

    Garcia, L; Bedos, C; Génermont, S; Braud, I; Cellier, P

    2011-09-01

    Ammonia and pesticide volatilization in the field is a surface phenomenon involving physical and chemical processes that depend on the soil surface temperature and water content. The water transfer, heat transfer and energy budget sub models of volatilization models are adapted from the most commonly accepted formalisms and parameterizations. They are less detailed than the dedicated models describing water and heat transfers and surface status. The aim of this work was to assess the ability of one of the available mechanistic volatilization models, Volt'Air, to accurately describe the pedo-climatic conditions of a soil surface at the required time and space resolution. The assessment involves: (i) a sensitivity analysis, (ii) an evaluation of Volt'Air outputs in the light of outputs from a reference Soil-Vegetation-Atmosphere Transfer model (SiSPAT) and three experimental datasets, and (iii) the study of three tests based on modifications of SiSPAT to establish the potential impact of the simplifying assumptions used in Volt'Air. The analysis confirmed that a 5 mm surface layer was well suited, and that Volt'Air surface temperature correlated well with the experimental measurements as well as with SiSPAT outputs. In terms of liquid water transfers, Volt'Air was overall consistent with SiSPAT, with discrepancies only during major rainfall events and dry weather conditions. The tests enabled us to identify the main source of the discrepancies between Volt'Air and SiSPAT: the lack of gaseous water transfer description in Volt'Air. They also helped to explain why neither Volt'Air nor SiSPAT was able to represent lower values of surface water content: current classical water retention and hydraulic conductivity models are not yet adapted to cases of very dry conditions. Given the outcomes of this study, we discuss to what extent the volatilization models can be improved and the questions they pose for current research in water transfer modeling and parameterization

  1. Field Observation of Setup

    National Research Council Canada - National Science Library

    Yemm, Sean

    2004-01-01

    Setup is defined as the superelevation of mean water surface within the surfzone and is caused by the reduction in wave momentum shoreward of the breaking point and compensating positive pressure gradient...

  2. Experimental Evaluation of MIMO Terminals with User Influence in OTA Setups

    DEFF Research Database (Denmark)

    Fan, Wei; Kyösti, Pekka; Hentilä, Lassi

    2017-01-01

    channel models in a practical 3D multi-probe anechoic chamber (MPAC) setup. A terminal mock-up, operating at 2.55 GHz, together with a realistic user phantom was used, and channel models with different spatial and polarization profiles, DUT with different operation modes and orientation angles were tested....

  3. The Influence of Natural Frequency of the Experimental Set-up on the Friction Coefficient of Stainless Steel-304

    OpenAIRE

    M. A. Chowdhury; Md. M. Helali

    2010-01-01

    The present paper investigates experimentally the effect of natural frequency of the experimental set-up on friction property of stainless steel-304. To do so, a pin-on-disc apparatus having facility of vibrating the test samples at different directions, amplitudes and frequencies was designed and fabricated. The natural frequency of the set-up was varied by adding dead loads of the setup from 0 kg to 50 kg. At each added load the friction coefficient has been measured. Results show that both...

  4. SU-E-J-24: Can Fiducial Marker-Based Setup Using ExacTrac Be An Alternative to Soft Tissue-Based Setup Using Cone-Beam CT for Prostate IMRT?

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, S [Department of Radiation Oncology, Niigata University Medical and Dental Hospital (Japan); Utsunomiya, S; Abe, E; Aoyama, H [Department of Radiology, Niigata University Graduate School of Medical and Dental Sciences (Japan); Satou, H [Department of Radiation Oncology, Niigata Cancer Center Hospital (Japan); Sakai, H; Yamada, T [Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital (Japan)

    2015-06-15

    Purpose: To assess an accuracy of fiducial maker-based setup using ExacTrac (ExT-based setup) as compared with soft tissue-based setup using Cone-beam CT (CBCT-based setup) for patients with prostate cancer receiving intensity-modulated radiation therapy (IMRT) for the purpose of investigating whether ExT-based setup can be an alternative to CBCT-based setup. Methods: The setup accuracy was analyzed prospectively for 7 prostate cancer patients with implanted three fiducial markers received IMRT. All patients were treated after CBCT-based setup was performed and corresponding shifts were recorded. ExacTrac images were obtained before and after CBCT-based setup. The fiducial marker-based shifts were calculated based on those two images and recorded on the assumption that the setup correction was carried out by fiducial marker-based auto correction. Mean and standard deviation of absolute differences and the correlation between CBCT and ExT shifts were estimated. Results: A total of 178 image dataset were analyzed. On the differences between CBCT and ExT shifts, 133 (75%) of 178 image dataset resulted in smaller differences than 3 mm in all dimensions. Mean differences in the anterior-posterior (AP), superior-inferior (SI), and left-right (LR) dimensions were 1.8 ± 1.9 mm, 0.7 ± 1.9 mm, and 0.6 ± 0.8 mm, respectively. The percentages of shift agreements within ±3 mm were 76% for AP, 90% for SI, and 100% for LR. The Pearson coefficient of correlation for CBCT and ExT shifts were 0.80 for AP, 0.80 for SI, and 0.65 for LR. Conclusion: This work showed that the accuracy of ExT-based setup was correlated with that of CBCT-based setup, implying that ExT-based setup has a potential ability to be an alternative to CBCT-based setup. The further work is to specify the conditions that ExT-based setup can provide the accuracy comparable to CBCT-based setup.

  5. Collider shot setup for Run 2 observations and suggestions

    International Nuclear Information System (INIS)

    Annala, J.; Joshel, B.

    1996-01-01

    This note is intended to provoke discussion on Collider Run II shot setup. We hope this is a start of activities that will converge on a functional description of what is needed for shot setups in Collider Run II. We will draw on observations of the present shot setup to raise questions and make suggestions for the next Collider run. It is assumed that the reader has some familiarity with the Collider operational issues. Shot setup is defined to be the time between the end of a store and the time the Main Control Room declares colliding beams. This is the time between Tevatron clock events SCE and SCB. This definition does not consider the time experiments use to turn on their detectors. This analysis was suggested by David Finley. The operational scenarios for Run II will require higher levels of reliability and speed for shot setup. See Appendix I and II. For example, we estimate that a loss of 3 pb -1 /week (with 8 hour stores) will occur if shot setups take 90 minutes instead of 30 minutes. In other words: If you do 12 shots for one week and accept an added delay of one minute in each shot, you will loose more than 60 nb -1 for that week alone (based on a normal shot setup of 30 minutes). These demands should lead us to be much more pedantic about all the factors that affect shot setups. Shot setup will be viewed as a distinct process that is composed of several inter- dependent 'components': procedures, hardware, controls, and sociology. These components don't directly align with the different Accelerator Division departments, but are topical groupings of the needed accelerator functions. Defining these components, and categorizing our suggestions within them, are part of the goal of this document. Of course, some suggestions span several of these components

  6. In beam test of a transient magnetic field based g factor setup

    International Nuclear Information System (INIS)

    Saxena, Mansi; Mandal, S.; Siwal, Davinder; Kumar, Chandan; Goyal, Savi; Garg, Ritika; Khushboo; Rohilla, Aman; Kumar, Naveen; Kumar, S.; Chamoli, S.; Mandal, A.; Kumar, Rajesh; Barua, P.; Kumar, R.; Gujjar, R.; Bala, Indu; Singh, R.P.; Muralithar, S.; Rehman, Anisur; Roy, Minakshi

    2012-01-01

    Magnetic moments or g factors provide substantial information on the microscopic structure of the nuclei. Since the g factor is very different in sign and magnitude for neutrons and protons, therefore they can serve as a good indicator as to which nucleon contributes most to the wave function of that state. There are different techniques available for measuring g factors depending on the lifetime of the state involved. Using transient field technique we can measure the g factor of nuclei having a lifetime of the order of several hundreds of femto seconds. To measure the g factor of such low lifetime states we have designed and fabricated a setup based on the Transient Field Technique Measurement

  7. Model-based setup assistant for progressive tools

    Science.gov (United States)

    Springer, Robert; Gräler, Manuel; Homberg, Werner; Henke, Christian; Trächtler, Ansgar

    2018-05-01

    In the field of production systems, globalization and technological progress lead to increasing requirements regarding part quality, delivery time and costs. Hence, today's production is challenged much more than a few years ago: it has to be very flexible and produce economically small batch sizes to satisfy consumer's demands and avoid unnecessary stock. Furthermore, a trend towards increasing functional integration continues to lead to an ongoing miniaturization of sheet metal components. In the industry of electric connectivity for example, the miniaturized connectors are manufactured by progressive tools, which are usually used for very large batches. These tools are installed in mechanical presses and then set up by a technician, who has to manually adjust a wide range of punch-bending operations. Disturbances like material thickness, temperatures, lubrication or tool wear complicate the setup procedure. In prospect of the increasing demand of production flexibility, this time-consuming process has to be handled more and more often. In this paper, a new approach for a model-based setup assistant is proposed as a solution, which is exemplarily applied in combination with a progressive tool. First, progressive tools, more specifically, their setup process is described and based on that, the challenges are pointed out. As a result, a systematic process to set up the machines is introduced. Following, the process is investigated with an FE-Analysis regarding the effects of the disturbances. In the next step, design of experiments is used to systematically develop a regression model of the system's behaviour. This model is integrated within an optimization in order to calculate optimal machine parameters and the following necessary adjustment of the progressive tool due to the disturbances. Finally, the assistant is tested in a production environment and the results are discussed.

  8. Objected constrained registration and manifold learning: A new patient setup approach in image guided radiation therapy of thoracic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chen Ting; Jabbour, Salma K.; Haffty, Bruce G.; Yue, Ning [Radiation Oncology Department, Cancer Institute of New Jersey, University of Medicine and Dentistry of New Jersey, 195 Little Albany Street, New Brunswick, New Jersey 08901 (United States); Qin Songbing [Department of Radiation Oncology, The First Affiliated Hospital of Soochow University, Suzhou 215006 (China)

    2013-04-15

    Purpose: The management of thoracic malignancies with radiation therapy is complicated by continuous target motion. In this study, a real time motion analysis approach is proposed to improve the accuracy of patient setup. Methods: For 11 lung cancer patients a long training fluoroscopy was acquired before the first treatment, and multiple short testing fluoroscopies were acquired weekly at the pretreatment patient setup of image guided radiotherapy (IGRT). The data analysis consisted of three steps: first a 4D target motion model was constructed from 4DCT and projected to the training fluoroscopy through deformable registration. Then the manifold learning method was used to construct a 2D subspace based on the target motion (kinetic) and location (static) information in the training fluoroscopy. Thereafter the respiratory phase in the testing fluoroscopy was determined by finding its location in the subspace. Finally, the phase determined testing fluoroscopy was registered to the corresponding 4DCT to derive the pretreatment patient position adjustment for the IGRT. The method was tested on clinical image sets and numerical phantoms. Results: The registration successfully reconstructed the 4D motion model with over 98% volume similarity in 4DCT, and over 95% area similarity in the training fluoroscopy. The machine learning method derived the phase values in over 98% and 93% test images of the phantom and patient images, respectively, with less than 3% phase error. The setup approach achieved an average accumulated setup error less than 1.7 mm in the cranial-caudal direction and less than 1 mm in the transverse plane. All results were validated against the ground truth of manual delineations by an experienced radiation oncologist. The expected total time for the pretreatment setup analysis was less than 10 s. Conclusions: By combining the registration and machine learning, the proposed approach has the potential to improve the accuracy of pretreatment setup for

  9. Objected constrained registration and manifold learning: A new patient setup approach in image guided radiation therapy of thoracic cancer

    International Nuclear Information System (INIS)

    Chen Ting; Jabbour, Salma K.; Haffty, Bruce G.; Yue, Ning; Qin Songbing

    2013-01-01

    Purpose: The management of thoracic malignancies with radiation therapy is complicated by continuous target motion. In this study, a real time motion analysis approach is proposed to improve the accuracy of patient setup. Methods: For 11 lung cancer patients a long training fluoroscopy was acquired before the first treatment, and multiple short testing fluoroscopies were acquired weekly at the pretreatment patient setup of image guided radiotherapy (IGRT). The data analysis consisted of three steps: first a 4D target motion model was constructed from 4DCT and projected to the training fluoroscopy through deformable registration. Then the manifold learning method was used to construct a 2D subspace based on the target motion (kinetic) and location (static) information in the training fluoroscopy. Thereafter the respiratory phase in the testing fluoroscopy was determined by finding its location in the subspace. Finally, the phase determined testing fluoroscopy was registered to the corresponding 4DCT to derive the pretreatment patient position adjustment for the IGRT. The method was tested on clinical image sets and numerical phantoms. Results: The registration successfully reconstructed the 4D motion model with over 98% volume similarity in 4DCT, and over 95% area similarity in the training fluoroscopy. The machine learning method derived the phase values in over 98% and 93% test images of the phantom and patient images, respectively, with less than 3% phase error. The setup approach achieved an average accumulated setup error less than 1.7 mm in the cranial-caudal direction and less than 1 mm in the transverse plane. All results were validated against the ground truth of manual delineations by an experienced radiation oncologist. The expected total time for the pretreatment setup analysis was less than 10 s. Conclusions: By combining the registration and machine learning, the proposed approach has the potential to improve the accuracy of pretreatment setup for

  10. Detection of patient setup errors with a portal image - DRR registration software application.

    Science.gov (United States)

    Sutherland, Kenneth; Ishikawa, Masayori; Bengua, Gerard; Ito, Yoichi M; Miyamoto, Yoshiko; Shirato, Hiroki

    2011-02-18

    The purpose of this study was to evaluate a custom portal image - digitally reconstructed radiograph (DRR) registration software application. The software works by transforming the portal image into the coordinate space of the DRR image using three control points placed on each image by the user, and displaying the fused image. In order to test statistically that the software actually improves setup error estimation, an intra- and interobserver phantom study was performed. Portal images of anthropomorphic thoracic and pelvis phantoms with virtually placed irradiation fields at known setup errors were prepared. A group of five doctors was first asked to estimate the setup errors by examining the portal and DRR image side-by-side, not using the software. A second group of four technicians then estimated the same set of images using the registration software. These two groups of human subjects were then compared with an auto-registration feature of the software, which is based on the mutual information between the portal and DRR images. For the thoracic case, the average distance between the actual setup error and the estimated error was 4.3 ± 3.0 mm for doctors using the side-by-side method, 2.1 ± 2.4 mm for technicians using the registration method, and 0.8 ± 0.4mm for the automatic algorithm. For the pelvis case, the average distance between the actual setup error and estimated error was 2.0 ± 0.5 mm for the doctors using the side-by-side method, 2.5 ± 0.4 mm for technicians using the registration method, and 2.0 ± 1.0 mm for the automatic algorithm. The ability of humans to estimate offset values improved statistically using our software for the chest phantom that we tested. Setup error estimation was further improved using our automatic error estimation algorithm. Estimations were not statistically different for the pelvis case. Consistency improved using the software for both the chest and pelvis phantoms. We also tested the automatic algorithm with a

  11. Blanket Cooling Plates Mock-ups Manufactured in different Diffusion Weld Setup

    International Nuclear Information System (INIS)

    Von Der Weth, A.; Aktaa, J.

    2007-01-01

    Full text of publication follows: The breeding blanket box is considered as one of the most important components of a future fusion power plant. It will be assembled by so called cooling plates (CP) with a system of internal cooling channels. Such a CP is produced by two symmetric half pieces with half milled-in channels. Both pieces will be joined by a diffusion weld (DW) process. Within recent years a two step DW process for different EUROFER batches has been developed. It has been first applied to small laboratory scaled samples with dimensions of 25 mm x 30 mm x 40 mm. Then the DW process had then been successfully transferred to so called compact mock ups which are small CPs with dimensions of 67 mm x 70 mm x 50 mm. As third step this process has been used to manufacture a CP (465 mm x 205 mm x 50 mm) of a breeder unit in an industrial uniaxial diffusion weld setup. This paper treats the manufacturing sequence of a cooling plate and a first wall mock up in an industrial hot isostatic pressing (HIP) setup. The firstly laboratory specimens scaled diffusion weld process has been adjusted to different cooling channel dimensions and a different DW setup. The weld quality is investigated by tensile and Charpy impact testing. This allows comparison of the weld quality of mock ups welded in different DW setups. (authors)

  12. Study of the Switching Errors in an RSFQ Switch by Using a Computerized Test Setup

    International Nuclear Information System (INIS)

    Kim, Se Hoon; Baek, Seung Hun; Yang, Jung Kuk; Kim, Jun Ho; Kang, Joon Hee

    2005-01-01

    The problem of fluctuation-induced digital errors in a rapid single flux quantum (RSFQ) circuit has been a very important issue. In this work, we calculated the bit error rate of an RSFQ switch used in superconductive arithmetic logic unit (ALU). RSFQ switch should have a very low error rate in the optimal bias. Theoretical estimates of the RSFQ error rate are on the order of 10 -50 per bit operation. In this experiment, we prepared two identical circuits placed in parallel. Each circuit was composed of 10 Josephson transmission lines (JTLs) connected in series with an RSFQ switch placed in the middle of the 10 JTLs. We used a splitter to feed the same input signal to both circuits. The outputs of the two circuits were compared with an RSFQ exclusive OR (XOR) to measure the bit error rate of the RSFQ switch. By using a computerized bit-error-rate test setup, we measured the bit error rate of 2.18 x 10 -12 when the bias to the RSFQ switch was 0.398 mA that was quite off from the optimum bias of 0.6 mA.

  13. A dedicated AMS setup for medium mass isotopes at the Cologne FN tandem accelerator

    Science.gov (United States)

    Schiffer, M.; Altenkirch, R.; Feuerstein, C.; Müller-Gatermann, C.; Hackenberg, G.; Herb, S.; Bhandari, P.; Heinze, S.; Stolz, A.; Dewald, A.

    2017-09-01

    AMS measurements of medium mass isotopes, e.g. of 53Mn and 60Fe, are gaining interest in various fields of operation, especially geoscience. Therefore a dedicated AMS setup has been built at the Cologne 10 MV FN tandem accelerator. This setup is designed to obtain a sufficient suppression of the stable isobars at energies around 100 MeV. In this contribution we report on the actual status of the new setup and the first in-beam tests of its individual components. The isobar suppression is done with (dE/dx) techniques using combinations of energy degrader foils with an electrostatic analyzer (ESA) and a time of flight (ToF) system, as well as a (dE/dx),E gas ionization detector. Furthermore, the upgraded ion source and its negative ion yield measurement for MnO- are presented.

  14. The compact and inexpensive arrowhead setup for holographic interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Ladera, Celso L; Donoso, Guillermo, E-mail: clladera@usb.v [Departamento de Fisica, Universidad Simon BolIvar, Apdo. 89000, Caracas 1086 (Venezuela, Bolivarian Republic of)

    2011-07-15

    Hologram recording and holographic interferometry are intrinsically sensitive to phase changes, and therefore both are easily perturbed by minuscule optical path perturbations. It is therefore very convenient to bank on holographic setups with a reduced number of optical components. Here we present a compact off-axis holographic setup that requires neither a collimator nor a beam-splitter, and whose layout is reminiscent of an arrowhead. We show that this inexpensive setup is a good alternative for the study and applications of scientific holography by measuring small displacements and deformations of a body. The arrowhead setup will be found particularly useful for holography and holographic interferometry experiments and projects in teaching laboratories.

  15. Evaluation of overall setup accuracy and adequate setup margins in pelvic image-guided radiotherapy: Comparison of the male and female patients

    International Nuclear Information System (INIS)

    Laaksomaa, Marko; Kapanen, Mika; Tulijoki, Tapio; Peltola, Seppo; Hyödynmaa, Simo; Kellokumpu-Lehtinen, Pirkko-Liisa

    2014-01-01

    We evaluated adequate setup margins for the radiotherapy (RT) of pelvic tumors based on overall position errors of bony landmarks. We also estimated the difference in setup accuracy between the male and female patients. Finally, we compared the patient rotation for 2 immobilization devices. The study cohort included consecutive 64 male and 64 female patients. Altogether, 1794 orthogonal setup images were analyzed. Observer-related deviation in image matching and the effect of patient rotation were explicitly determined. Overall systematic and random errors were calculated in 3 orthogonal directions. Anisotropic setup margins were evaluated based on residual errors after weekly image guidance. The van Herk formula was used to calculate the margins. Overall, 100 patients were immobilized with a house-made device. The patient rotation was compared against 28 patients immobilized with CIVCO's Kneefix and Feetfix. We found that the usually applied isotropic setup margin of 8 mm covered all the uncertainties related to patient setup for most RT treatments of the pelvis. However, margins of even 10.3 mm were needed for the female patients with very large pelvic target volumes centered either in the symphysis or in the sacrum containing both of these structures. This was because the effect of rotation (p ≤ 0.02) and the observer variation in image matching (p ≤ 0.04) were significantly larger for the female patients than for the male patients. Even with daily image guidance, the required margins remained larger for the women. Patient rotations were largest about the lateral axes. The difference between the required margins was only 1 mm for the 2 immobilization devices. The largest component of overall systematic position error came from patient rotation. This emphasizes the need for rotation correction. Overall, larger position errors and setup margins were observed for the female patients with pelvic cancer than for the male patients

  16. Using a Robust Design Approach to Optimize Chair Set-up in Wheelchair Sport

    Directory of Open Access Journals (Sweden)

    David S. Haydon

    2018-02-01

    Full Text Available Optimisation of wheelchairs for court sports is currently a difficult and time-consuming process due to the broad range of impairments across athletes, difficulties in monitoring on-court performance, and the trade-off set-up that parameters have on key performance variables. A robust design approach to this problem can potentially reduce the amount of testing required, and therefore allow for individual on-court assessments. This study used orthogonal design with four set-up factors (seat height, depth, and angle, as well as tyre pressure at three levels (current, decreased, and increased for three elite wheelchair rugby players. Each player performed two maximal effort sprints from a stationary position in nine different set-ups, with this allowing for detailed analysis of each factor and level. Whilst statistical significance is difficult to obtain due to the small sample size, meaningful difference results aligning with previous research findings were identified and provide support for the use of this approach.

  17. Patients setup verification tool for RT (PSVTs): DRR, simulation, portal and digital images

    International Nuclear Information System (INIS)

    Lee, Suk; Seong, Jin Sil; Chu, Sung Sil; Lee, Chang Geol; Suh, Chang Ok; Kwon, Soo Il

    2003-01-01

    To develop a patients' setup verification tool (PSVT) to verify the alignment of the machine and the target isocenters, and the reproducibility of patients' setup for three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (MRT). The utilization of this system is evaluated through phantom and patient case studies. We developed and clinically tested a new method for patients' setup verification, using digitally reconstructed radiography (DRR), simulation, portal and digital images. The PSVT system was networked to a Pentium PC for the transmission of the acquired images to the PC for analysis. To verify the alignment of the machine and target isocenters, orthogonal pairs of simulation images were used as verification images. Errors in the isocenter alignment were measured by comparing the verification images with DRR of CT images. Orthogonal films were taken of all the patients once a week. These verification films were compared with the DRR were used for the treatment setup. By performing this procedure every treatment, using humanoid phantom and patient cases, the errors of localization can be analyzed, with adjustments made from the translation. The reproducibility of the patients' setup was verified using portal and digital images. The PSVT system was developed to verify the alignment of the machine and the target isocenters, and the reproducibility of the patients' setup for 3DCRT and IMRT The results show that the localization errors are 0.8±0.2 mm (AP) and 1.0±0.3 mm (Lateral) in the cases relating to the brain and 1.1± 0.5 mm (AP) and 1.0±0.6 mm (Lateral) in the cases relating to the pelvis. The reproducibility of the patients' setup was verified by visualization, using real-time image acquisition, leading to the practical utilization of our software. A PSVT system was developed for the verification of the alignment between machine and the target isocenters, and the reproducibility of the patients' setup in 3DCRT and IMRT

  18. Diagnostic Setup for Characterization of Near-Anode Processes in Hall Thrusters

    International Nuclear Information System (INIS)

    Dorf, L.; Raitses, Y.; Fisch, N.J.

    2003-01-01

    A diagnostic setup for characterization of near-anode processes in Hall-current plasma thrusters consisting of biased and emissive electrostatic probes, high-precision positioning system and low-noise electronic circuitry was developed and tested. Experimental results show that radial probe insertion does not cause perturbations to the discharge and therefore can be used for accurate near-anode measurements

  19. A new setup for the underground study of capture reactions

    CERN Document Server

    Casella, C; Lemut, A; Limata, B; Bemmerer, D; Bonetti, R; Broggini, C; Campajola, L; Cocconi, P; Corvisiero, P; Cruz, J; D'Onofrio, A; Formicola, A; Fülöp, Z; Gervino, G; Gialanella, L; Guglielmetti, A; Gustavino, C; Gyürky, G; Loiano, A; Imbriani, G; Jesus, A P; Junker, M; Musico, P; Ordine, A; Parodi, F; Parolin, M; Pinto, J V; Prati, P; Ribeiro, J P; Roca, V; Rogalla, D; Rolfs, C; Romano, M; Rossi-Alvarez, C; Rottura, A; Schuemann, F; Somorjai, E; Strieder, F; Terrasi, F; Trautvetter, H P; Vomiero, A; Zavatarelli, S

    2002-01-01

    For the study of astrophysically relevant capture reactions in the underground laboratory LUNA a new setup of high sensitivity has been implemented. The setup includes a windowless gas target, a 4 pi BGO summing crystal, and beam calorimeters. The setup has been recently used to measure the d(p,gamma) sup 3 He cross-section for the first time within its solar Gamow peak, i.e. down to 2.5 keV c.m. energy. The features of the optimized setup are described.

  20. Simple optical setup implementation for digital Fourier transform holography

    Energy Technology Data Exchange (ETDEWEB)

    De Oliveira, G N [Pos-graduacao em Engenharia Mecanica, TEM/PGMEC, Universidade Federal Fluminense, Rua Passo da Patria, 156, Niteroi, R.J., Cep.: 24.210-240 (Brazil); Rodrigues, D M C; Dos Santos, P A M, E-mail: pams@if.uff.br [Instituto de Fisica, Laboratorio de Optica Nao-linear e Aplicada, Universidade Federal Fluminense, Av. Gal. Nilton Tavares de Souza, s/n, Gragoata, Niteroi, R.J., Cep.:24.210-346 (Brazil)

    2011-01-01

    In the present work a simple implementation of Digital Fourier Transform Holography (DFTH) setup is discussed. This is obtained making a very simple modification in the classical setup arquiteture of the Fourier Transform holography. It is also demonstrated the easy and practical viability of the setup in an interferometric application for mechanical parameters determination. The work is also proposed as an interesting advanced introductory training for graduated students in digital holography.

  1. The use of food grade oil in the prevention of vase tunicate fouling on mussel aquaculture gear

    Directory of Open Access Journals (Sweden)

    Jiselle A. BAKKER

    2011-01-01

    Full Text Available Current mitigation strategies against invasive tunicates on mussel aquaculture gear in Prince Edward Island concentrate on labour-intensive and costly fouling removal. Instead of removal, this study focused on preventing the settlement of the vase tunicate Ciona intestinalis and other fouling organisms by applying a layer of food grade oil to gear prior to recruitment. Laboratory tests established the adherence and persistence of shortening, a food grade oil with a melting point exceeding ambient water temperatures, to rope and mussels. In situ tests showed that shortening decreased C. intestinalis weight and abundance on buoys, spat collector ropes and collector plates but not on mussel socks. Fouling by algae and other tunicates was significantly reduced on most substrates. There were no detrimental effects of shortening treatment on mussel length and abundance on mussel socks, but total mussel weight was significantly lower on shortening-treated socks. Shortening treatment did not significantly affect mussel spat settlement on spat collector ropes, but further evaluation is required. Overall, shortening application has considerable potential for reducing tunicate and other fouling, particularly on buoys.

  2. Set-up for pulse radiolysis of agressive substances

    International Nuclear Information System (INIS)

    Kozlowska-Milner, E.; Broszkiewicz, R.; Stanikowski, J.

    1975-01-01

    A set-up for the pulse radiolysis of aggressive substances with a relatively low consumption of the liquid, tested for anhydrous HNO 3 , has been described. The samples have been irradiated with single pulses of 10 MeV electrons at the linear accelerator type LAE 13-9. The absorption spectra of the irradiated samples (within a range of 300-800 nm) were provided by a xenon lamp. The variations of the voltage from the photomultiplier, coupled with an oscilloscope, were registered with the aid of a Polaroid camera. (T.G.)

  3. The use of adaptive radiation therapy to reduce setup error: a prospective clinical study

    International Nuclear Information System (INIS)

    Yan Di; Wong, John; Vicini, Frank; Robertson, John; Horwitz, Eric; Brabbins, Donald; Cook, Carla; Gustafson, Gary; Stromberg, Jannifer; Martinez, Alvaro

    1996-01-01

    Purpose: Adaptive Radiation Therapy (ART) is a closed-loop feedback process where each patients treatment is adaptively optimized according to the individual variation information measured during the course of treatment. The process aims to maximize the benefits of treatment for the individual patient. A prospective study is currently being conducted to test the feasibility and effectiveness of ART for clinical use. The present study is limited to compensating the effects of systematic setup error. Methods and Materials: The study includes 20 patients treated on a linear accelerator equipped with a computer controlled multileaf collimator (MLC) and a electronic portal imaging device (EPID). Alpha cradles are used to immobilize those patients treated for disease in the thoracic and abdominal regions, and thermal plastic masks for the head and neck. Portal images are acquired daily. Setup error of each treatment field is quantified off-line every day. As determined from an earlier retrospective study of different clinical sites, the measured setup variation from the first 4 to 9 days, are used to estimate systematic setup error and the standard deviation of random setup error for each field. Setup adjustment is made if estimated systematic setup error of the treatment field was larger than or equal to 2 mm. Instead of the conventional approach of repositioning the patient, setup correction is implemented by reshaping MLC to compensate for the estimated systematic error. The entire process from analysis of portal images to the implementation of the modified MLC field is performed via computer network. Systematic and random setup errors of the treatment after adjustment are compared with those prior to adjustment. Finally, the frequency distributions of block overlap cumulated throughout the treatment course are evaluated. Results: Sixty-seven percent of all treatment fields were reshaped to compensate for the estimated systematic errors. At the time of this writing

  4. High-resolution continuous flow analysis setup for water isotopic measurement from ice cores using laser spectroscopy

    Science.gov (United States)

    Emanuelsson, B. D.; Baisden, W. T.; Bertler, N. A. N.; Keller, E. D.; Gkinis, V.

    2014-12-01

    Here we present an experimental setup for water stable isotopes (δ18O and δD) continuous flow measurements. It is the first continuous flow laser spectroscopy system that is using Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS; analyzer manufactured by Los Gatos Research - LGR) in combination with an evaporation unit to continuously analyze sample from an ice core. A Water Vapor Isotopic Standard Source (WVISS) calibration unit, manufactured by LGR, was modified to: (1) increase the temporal resolution by reducing the response time (2) enable measurements on several water standards, and (3) to reduce the influence from memory effects. While this setup was designed for the Continuous Flow Analysis (CFA) of ice cores, it can also continuously analyze other liquid or vapor sources. The modified setup provides a shorter response time (~54 and 18 s for 2013 and 2014 setup, respectively) compared to the original WVISS unit (~62 s), which is an improvement in measurement resolution. Another improvement compared to the original WVISS is that the modified setup has a reduced memory effect. Stability tests comparing the modified WVISS and WVISS setups were performed and Allan deviations (σAllan) were calculated to determine precision at different averaging times. For the 2013 modified setup the precision after integration times of 103 s are 0.060 and 0.070‰ for δ18O and δD, respectively. For the WVISS setup the corresponding σAllan values are 0.030, 0.060 and 0.043‰ for δ18O, δD and δ17O, respectively. For the WVISS setup the precision is 0.035, 0.070 and 0.042‰ after 103 s for δ18O, δD and δ17O, respectively. Both the modified setups and WVISS setup are influenced by instrumental drift with δ18O being more drift sensitive than δD. The σAllan values for δ18O of 0.30 and 0.18‰ for the modified (2013) and WVISS setup, respectively after averaging times of 104 s (2.78 h). The Isotopic Water Analyzer (IWA)-modified WVISS setup used during the

  5. Analysis of patient setup accuracy using electronic portal imaging device

    International Nuclear Information System (INIS)

    Onogi, Yuzo; Aoki, Yukimasa; Nakagawa, Keiichi

    1996-01-01

    Radiation therapy is performed in many fractions, and accurate patient setup is very important. This is more significant nowadays because treatment planning and radiation therapy are more precisely performed. Electronic portal imaging devices and automatic image comparison algorithms let us analyze setup deviations quantitatively. With such in mind we developed a simple image comparison algorithm. Using 2459 electronic verification images (335 ports, 123 treatment sites) generated during the past three years at our institute, we evaluated the results of the algorithm, and analyzed setup deviations according to the area irradiated, use of a fixing device (shell), and arm position. Calculated setup deviation was verified visually and their fitness was classified into good, fair, bad, and incomplete. The result was 40%, 14%, 22%, 24% respectively. Using calculated deviations classified as good (994 images), we analyzed setup deviations. Overall setup deviations described in 1 SD along axes x, y, z, was 1.9 mm, 2.5 mm, 1.7 mm respectively. We classified these deviations into systematic and random components, and found that random error was predominant in our institute. The setup deviations along axis y (cranio-caudal direction) showed larger distribution when treatment was performed with the shell. Deviations along y (cranio-caudal) and z (anterior-posterior) had larger distribution when treatment occurred with the patient's arm elevated. There was a significant time-trend error, whose deviations become greater with time. Within all evaluated ports, 30% showed a time-trend error. Using an electronic portal imaging device and automatic image comparison algorithm, we are able to analyze setup deviations more precisely and improve setup method based on objective criteria. (author)

  6. Comparison of computer workstation with light box for detecting setup errors from portal images

    International Nuclear Information System (INIS)

    Boxwala, Aziz A.; Chaney, Edward L.; Fritsch, Daniel S.; Raghavan, Suraj; Coffey, Christopher S.; Major, Stacey A.; Muller, Keith E.

    1999-01-01

    Purpose: Observer studies were conducted to test the hypothesis that radiation oncologists using a computer workstation for portal image analysis can detect setup errors at least as accurately as when following standard clinical practice of inspecting portal films on a light box. Methods and Materials: In a controlled observer study, nine radiation oncologists used a computer workstation, called PortFolio, to detect setup errors in 40 realistic digitally reconstructed portal radiograph (DRPR) images. PortFolio is a prototype workstation for radiation oncologists to display and inspect digital portal images for setup errors. PortFolio includes tools for image enhancement; alignment of crosshairs, field edges, and anatomic structures on reference and acquired images; measurement of distances and angles; and viewing registered images superimposed on one another. The test DRPRs contained known in-plane translation or rotation errors in the placement of the fields over target regions in the pelvis and head. Test images used in the study were also printed on film for observers to view on a light box and interpret using standard clinical practice. The mean accuracy for error detection for each approach was measured and the results were compared using repeated measures analysis of variance (ANOVA) with the Geisser-Greenhouse test statistic. Results: The results indicate that radiation oncologists participating in this study could detect and quantify in-plane rotation and translation errors more accurately with PortFolio compared to standard clinical practice. Conclusions: Based on the results of this limited study, it is reasonable to conclude that workstations similar to PortFolio can be used efficaciously in clinical practice

  7. Operational Range of Several Interface Algorithms for Different Power Hardware-In-The-Loop Setups

    Directory of Open Access Journals (Sweden)

    Ron Brandl

    2017-11-01

    Full Text Available The importance of Power Hardware-in-the-Loop (PHIL experiments is rising more and more over the last decade in the field of power system and components testing. Due to the bidirectional exchange between virtual and physical systems, a true-to-reality interface is essential; however, linking several dynamic systems, stability issues can challenge the experiments, the components under test, and the individuals performing the experiments. Over the time, several interface algorithms (IA have been developed and analyzed, each having different advantages and disadvantages in view of combining virtual simulations with physical power systems. Finally, IA are very specific to the kind of PHIL experiment. This paper investigates the operational range of several IA for specific PHIL setups by calculations, simulations, and measurements. Therefore, a selection of the mainly used respectively optimized IA is mathematically described. The operational range is verified in a PHIL system testing environment. Furthermore, in order to study the influence of different PHIL setups, according to software and hardware impedance, different tests using linear and switching amplifiers are performed.

  8. The COMPASS Setup for Physics with Hadron Beams

    CERN Document Server

    Abbon, Ph.; Akhunzyanov, R.; Alexandrov, Yu.; Alexeev, M.G.; Alexeev, G.D.; Amoroso, A.; Andrieux, V.; Anosov, V.; Austregesilo, A.; Badelek, B.; Balestra, F.; Barth, J.; Baum, G.; Beck, R.; Bedfer, Y.; Berlin, A.; Bernhard, J.; Bicker, K.; Bielert, E.R.; Bieling, J.; Birsa, R.; Bisplinghoff, J.; Bodlak, M.; Boer, M.; Bordalo, P.; Bradamante, F.; Braun, C.; Bressan, A.; Buchele, M.; Burtin, E.; Capozza, L.; Ciliberti, P.; Chiosso, M.; Chung, S.U.; Cicuttin, A.; Colantoni, M.; Cotte, D.; Crespo, M.L.; Curiel, Q.; Dafni, T.; Dalla Torre, S.; Dasgupta, S.S.; Dasgupta, S.; Denisov, O.Yu.; Desforge, D.; Dinkelbach, A.M.; Donskov, S.V.; Doshita, N.; Duic, V.; Dunnweber, W.; Durand, D.; Dziewiecki, M.; Efremov, A.; Elia, C.; Eversheim, P.D.; Eyrich, W.; Faessler, M.; Ferrero, A.; Finger, M.; M. Finger jr; Fischer, H.; Franco, C.; von Hohenesche, N. du Fresne; Friedrich, J.M.; Frolov, V.; Gatignon, L.; Gautheron, F.; Gavrichtchouk, O.P.; Gerassimov, S.; Geyer, R.; Giganon, A.; Gnesi, I.; Gobbo, B.; Goertz, S.; Gorzellik, M.; Grabmuller, S.; Grasso, A.; Gregori, M.; Grube, B.; Grussenmeyer, T.; Guskov, A.; Haas, F.; von Harrach, D.; Hahne, D.; Hashimoto, R.; Heinsius, F.H.; Herrmann, F.; Hinterberger, F.; Hoppner, Ch.; Horikawa, N.; d'Hose, N.; Huber, S.; Ishimoto, S.; Ivanov, A.; Ivanshin, Yu.; Iwata, T.; Jahn, R.; Jary, V.; Jasinski, P.; Jorg, P.; Joosten, R.; Kabuss, E.; Ketzer, B.; Khaustov, G.V.; Khokhlov, Yu. A.; Kisselev, Yu.; Klein, F.; Klimaszewski, K.; Koivuniemi, J.H.; Kolosov, V.N.; Kondo, K.; Konigsmann, K.; Konorov, I.; Konstantinov, V.F.; Kotzinian, A.M.; Kouznetsov, O.; Kramer, M.; Kroumchtein, Z.V.; Kuchinski, N.; Kuhn, R.; Kunne, F.; Kurek, K.; Kurjata, R.P.; Lednev, A.A.; Lehmann, A.; Levillain, M.; Levorato, S.; Lichtenstadt, J.; Maggiora, A.; Magnon, A.; Makke, N.; Mallot, G.K.; Marchand, C.; Marroncle, J.; Martin, A.; Marzec, J.; Matousek, J.; Matsuda, H.; Matsuda, T.; Menon, G.; Meshcheryakov, G.; Meyer, W.; Michigami, T.; Mikhailov, Yu. V.; Miyachi, Y.; Moinester, M.A.; Nagaytsev, A.; Nagel, T.; Nerling, F.; Neubert, S.; Neyret, D.; Nikolaenko, V.I.; Novy, J.; Nowak, W.D.; Nunes, Ana Sofia; Olshevsky, A.G.; Orlov, I.; Ostrick, M.; Panknin, R.; Panzieri, D.; Parsamyan, B.; Paul, S.; Pesaro, G.; Pesaro, V.; Peshekhonov, D.V.; Pires, C.; Platchkov, S.; Pochodzalla, J.; Polyakov, V.A.; Pretz, J.; Quaresma, M.; Quintans, C.; Ramos, S.; Regali, C.; Reicherz, G.; Reymond, J-M.; Rocco, E.; Rossiyskaya, N.S.; Rousse, J.Y.; Ryabchikov, D.I.; Rychter, A.; Samartsev, A.; Samoylenko, V.D.; Sandacz, A.; Sarkar, S.; Savin, I.A.; Sbrizzai, G.; Schiavon, P.; Schill, C.; Schluter, T.; Schmidt, K.; Schmieden, H.; Schonning, K.; Schopferer, S.; Schott, M.; Shevchenko, O.Yu.; Silva, L.; Sinha, L.; Sirtl, S.; Slunecka, M.; Sosio, S.; Sozzi, F.; Srnka, A.; Steiger, L.; Stolarski, M.; Sulc, M.; Sulej, R.; Suzuki, H.; Szabelski, A.; Szameitat, T.; Sznajder, P.; Takekawa, S.; Wolbeek, J. ter; Tessaro, S.; Tessarotto, F.; Thibaud, F.; Tskhay, V.; Uhl, S.; Uman, I.; Virius, M.; Wang, L.; Weisrock, T.; Weitzel, Q.; Wilfert, M.; Windmolders, R.; Wollny, H.; Zaremba, K.; Zavertyaev, M.; Zemlyanichkina, E.; Ziembicki, M.; Zink, A.

    2015-01-01

    The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well as new or upgraded detectors. The hadron setup is able to operate at the high incident hadron flux available at CERN. It is characterised by large angular and momentum coverages, large and nearly flat acceptances, and good two and three-particle mass resolutions. In 2008 and 2009 it was successfully used with positive and negative hadron beams and with liquid hydrogen and solid nuclear targets. This article describes the new and upgraded detectors and auxiliary equipment, outlines the reconstruction procedures used, and summarises the general performance of the setup.

  9. Studies of η' (ω) mesons with the crystal ball/TAPS setup at MAMI

    Energy Technology Data Exchange (ETDEWEB)

    Adlarson, Patrik [Institut fuer Kernphysik, Johannes Gutenberg Universitaet, Mainz (Germany); Collaboration: A2-Collaboration

    2015-07-01

    Precision studies of light meson decays are used to investigate a wide range of topics related to fundamental aspects of hadron physics. In particular, η' decays allow for tests of such diverse topics as ππ scattering lengths, the SU(3) singlet-octet mixing angle, quark mass differences and light-by-light contribution to the anomalous magnetic moment of the muon. Recently, a large statistics sample of η'(ω) mesons have been produced and collected with the Crystal Ball/TAPS setup at MAMI. An overview of the physics motivation, the experimental setup and preliminary results from the ongoing analyses are presented.

  10. Feasibility of geometrical verification of patient set-up using body contours and computed tomography data

    International Nuclear Information System (INIS)

    Ploeger, Lennert S.; Betgen, Anja; Gilhuijs, Kenneth G.A.; Herk, Marcel van

    2003-01-01

    Background and purpose: Body contours can potentially be used for patient set-up verification in external-beam radiotherapy and might enable more accurate set-up of patients prior to irradiation. The aim of this study is to test the feasibility of patient set-up verification using a body contour scanner. Material and methods: Body contour scans of 33 lung cancer and 21 head-and-neck cancer patients were acquired on a simulator. We assume that this dataset is representative for the patient set-up on an accelerator. Shortly before acquisition of the body contour scan, a pair of orthogonal simulator images was taken as a reference. Both the body contour scan and the simulator images were matched in 3D to the planning computed tomography scan. Movement of skin with respect to bone was quantified based on an analysis of variance method. Results: Set-up errors determined with body-contours agreed reasonably well with those determined with simulator images. For the lung cancer patients, the average set-up errors (mm)±1 standard deviation (SD) for the left-right, cranio-caudal and anterior-posterior directions were 1.2±2.9, -0.8±5.0 and -2.3±3.1 using body contours, compared to -0.8±3.2, -1.0±4.1 and -1.2±2.4 using simulator images. For the head-and-neck cancer patients, the set-up errors were 0.5±1.8, 0.5±2.7 and -2.2±1.8 using body contours compared to -0.4±1.2, 0.1±2.1, -0.1±1.8 using simulator images. The SD of the set-up errors obtained from analysis of the body contours were not significantly different from those obtained from analysis of the simulator images. Movement of the skin with respect to bone (1 SD) was estimated at 2.3 mm for lung cancer patients and 1.7 mm for head-and-neck cancer patients. Conclusion: Measurement of patient set-up using a body-contouring device is possible. The accuracy, however, is limited by the movement of the skin with respect to the bone. In situations where the error in the patient set-up is relatively large, it is

  11. RCT: Module 2.10, Access Control and Work Area Setup, Course 8776

    Energy Technology Data Exchange (ETDEWEB)

    Hillmer, Kurt T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-11

    This course presents information on radiological work permits (RWPs), various types of postings used in radiological areas, radiological area setups, access controls, and releases of material from radiological areas. All of these are fundamental duties of RCTs. This course will prepare the student with the skills necessary for radiological control technician (RCT) qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and providing in-thefield skills.

  12. Evaluation of RSA set-up from a clinical biplane fluoroscopy system for 3D joint kinematic analysis.

    Science.gov (United States)

    Bonanzinga, Tommaso; Signorelli, Cecilia; Bontempi, Marco; Russo, Alessandro; Zaffagnini, Stefano; Marcacci, Maurilio; Bragonzoni, Laura

    2016-01-01

    dinamic roentgen stereophotogrammetric analysis (RSA), a technique currently based only on customized radiographic equipment, has been shown to be a very accurate method for detecting three-dimensional (3D) joint motion. The aim of the present work was to evaluate the applicability of an innovative RSA set-up for in vivo knee kinematic analysis, using a biplane fluoroscopic image system. To this end, the Authors describe the set-up as well as a possible protocol for clinical knee joint evaluation. The accuracy of the kinematic measurements is assessed. the Authors evaluated the accuracy of 3D kinematic analysis of the knee in a new RSA set-up, based on a commercial biplane fluoroscopy system integrated into the clinical environment. The study was organized in three main phases: an in vitro test under static conditions, an in vitro test under dynamic conditions reproducing a flexion-extension range of motion (ROM), and an in vivo analysis of the flexion-extension ROM. For each test, the following were calculated, as an indication of the tracking accuracy: mean, minimum, maximum values and standard deviation of the error of rigid body fitting. in terms of rigid body fitting, in vivo test errors were found to be 0.10±0.05 mm. Phantom tests in static and kinematic conditions showed precision levels, for translations and rotations, of below 0.1 mm/0.2° and below 0.5 mm/0.3° respectively for all directions. the results of this study suggest that kinematic RSA can be successfully performed using a standard clinical biplane fluoroscopy system for the acquisition of slow movements of the lower limb. a kinematic RSA set-up using a clinical biplane fluoroscopy system is potentially applicable and provides a useful method for obtaining better characterization of joint biomechanics.

  13. A new experimental setup established for low-energy nuclear astrophysics studies

    International Nuclear Information System (INIS)

    Chen, S.Z.; Xu, S.W.; He, J.J.; Hu, J.; Rolfs, C.E.; Zhang, N.T.; Ma, S.B.; Zhang, L.Y.; Hou, S.Q.; Yu, X.Q.; Ma, X.W.

    2014-01-01

    An experimental setup for low-energy nuclear astrophysics studies has been recently established at the Institute of Modern Physics (IMP), Lanzhou, China. The driver machine is a 320 kV high voltage platform, which can provide intense currents of proton, alpha and many heavy ion beams. The energy of a proton beam was calibrated against the nominal platform high voltage by using a well-known resonant reaction of 11 B(p,γ) 12 C and a non-resonant reaction 12 C(p,γ) 13 N. The accuracy was achieved to be better than ±0.5 keV. The detection system consists of a Clover-type high-purity germanium detector, a silicon detector and a plastic scintillator. The performance of the detectors was tested by several experiments. The astrophysical S-factors of the 7 Li(p,γ) 8 Be and 7 Li(p,α) 3 He reactions were measured with this new setup, and our data agree with the values found in the literature. In addition, the upgrade of our driver machine and experimental setup has been discussed. As a future goal, a fascinating National Deep Underground Laboratory in China, the deepest underground laboratory all over the world, is prospected

  14. Precision assessment of model-based RSA for a total knee prosthesis in a biplanar set-up.

    Science.gov (United States)

    Trozzi, C; Kaptein, B L; Garling, E H; Shelyakova, T; Russo, A; Bragonzoni, L; Martelli, S

    2008-10-01

    Model-based Roentgen Stereophotogrammetric Analysis (RSA) was recently developed for the measurement of prosthesis micromotion. Its main advantage is that markers do not need to be attached to the implants as traditional marker-based RSA requires. Model-based RSA has only been tested in uniplanar radiographic set-ups. A biplanar set-up would theoretically facilitate the pose estimation algorithm, since radiographic projections would show more different shape features of the implants than in uniplanar images. We tested the precision of model-based RSA and compared it with that of the traditional marker-based method in a biplanar set-up. Micromotions of both tibial and femoral components were measured with both the techniques from double examinations of patients participating in a clinical study. The results showed that in the biplanar set-up model-based RSA presents a homogeneous distribution of precision for all the translation directions, but an inhomogeneous error for rotations, especially internal-external rotation presented higher errors than rotations about the transverse and sagittal axes. Model-based RSA was less precise than the marker-based method, although the differences were not significant for the translations and rotations of the tibial component, with the exception of the internal-external rotations. For both prosthesis components the precisions of model-based RSA were below 0.2 mm for all the translations, and below 0.3 degrees for rotations about transverse and sagittal axes. These values are still acceptable for clinical studies aimed at evaluating total knee prosthesis micromotion. In a biplanar set-up model-based RSA is a valid alternative to traditional marker-based RSA where marking of the prosthesis is an enormous disadvantage.

  15. Set-Up and Punchline as Figure and Ground

    DEFF Research Database (Denmark)

    Keisalo, Marianna Päivikki

    the two that cannot be resolved by appeal to either set-up or punchline, but traps thought between them in an ‘epistemological problem’ as comedian Louis CK put it. For comedians, set-ups and punchlines are basic tools, practical and concrete ways to create and organize material. They are also familiar...

  16. The Influence of Natural Frequency of the Experimental Set-up on the Friction Coefficient of Stainless Steel-304

    Directory of Open Access Journals (Sweden)

    M. A. Chowdhury

    2010-03-01

    Full Text Available The present paper investigates experimentally the effect of natural frequency of the experimental set-up on friction property of stainless steel-304. To do so, a pin-on-disc apparatus having facility of vibrating the test samples at different directions, amplitudes and frequencies was designed and fabricated. The natural frequency of the set-up was varied by adding dead loads of the setup from 0 kg to 50 kg. At each added load the friction coefficient has been measured. Results show that both the natural frequency and friction coefficient decrease with the increase of added loads. It has been also observed that the coefficient of friction increases with the increase of natural frequency of the experimental setup. The experimental results are also compared with those available in literature and simple physical explanations are provided.

  17. Application of video imaging for improvement of patient set-up

    International Nuclear Information System (INIS)

    Ploeger, Lennert S.; Frenay, Michel; Betgen, Anja; Bois, Josien A. de; Gilhuijs, Kenneth G.A.; Herk, Marcel van

    2003-01-01

    Background and purpose: For radiotherapy of prostate cancer, the patient is usually positioned in the left-right (LR) direction by aligning a single marker on the skin with the projection of a room laser. The aim of this study is to investigate the feasibility of a room-mounted video camera in combination with previously acquired CT data to improve patient set-up along the LR axis. Material and methods: The camera was mounted in the treatment room at the caudal side of the patient. For 22 patients with prostate cancer 127 video and portal images were acquired. The set-up error determined by video imaging was found by matching video images with rendered CT images using various techniques. This set-up error was retrospectively compared with the set-up error derived from portal images. It was investigated whether the number of corrections based on portal imaging would decrease if the information obtained from the video images had been used prior to irradiation. Movement of the skin with respect to bone was quantified using an analysis of variance method. Results: The measurement of the set-up error was most accurate for a technique where outlines and groins on the left and right side of the patient were delineated and aligned individually to the corresponding features extracted from the rendered CT image. The standard deviations (SD) of the systematic and random components of the set-up errors derived from the portal images in the LR direction were 1.5 and 2.1 mm, respectively. When the set-up of the patients was retrospectively adjusted based on the video images, the SD of the systematic and random errors decreased to 1.1 and 1.3 mm, respectively. From retrospective analysis, a reduction of the number of set-up corrections (from nine to six corrections) is expected when the set-up would have been adjusted using the video images. The SD of the magnitude of motion of the skin of the patient with respect to the bony anatomy was estimated to be 1.1 mm. Conclusion: Video

  18. Automation of a high-speed imaging setup for differential viscosity measurements

    Science.gov (United States)

    Hurth, C.; Duane, B.; Whitfield, D.; Smith, S.; Nordquist, A.; Zenhausern, F.

    2013-12-01

    We present the automation of a setup previously used to assess the viscosity of pleural effusion samples and discriminate between transudates and exudates, an important first step in clinical diagnostics. The presented automation includes the design, testing, and characterization of a vacuum-actuated loading station that handles the 2 mm glass spheres used as sensors, as well as the engineering of electronic Printed Circuit Board (PCB) incorporating a microcontroller and their synchronization with a commercial high-speed camera operating at 10 000 fps. The hereby work therefore focuses on the instrumentation-related automation efforts as the general method and clinical application have been reported earlier [Hurth et al., J. Appl. Phys. 110, 034701 (2011)]. In addition, we validate the performance of the automated setup with the calibration for viscosity measurements using water/glycerol standard solutions and the determination of the viscosity of an "unknown" solution of hydroxyethyl cellulose.

  19. Automation of a high-speed imaging setup for differential viscosity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hurth, C.; Duane, B.; Whitfield, D.; Smith, S.; Nordquist, A.; Zenhausern, F. [Center for Applied Nanobioscience and Medicine, The University of Arizona College of Medicine, 425 N 5th Street, Phoenix, Arizona 85004 (United States)

    2013-12-28

    We present the automation of a setup previously used to assess the viscosity of pleural effusion samples and discriminate between transudates and exudates, an important first step in clinical diagnostics. The presented automation includes the design, testing, and characterization of a vacuum-actuated loading station that handles the 2 mm glass spheres used as sensors, as well as the engineering of electronic Printed Circuit Board (PCB) incorporating a microcontroller and their synchronization with a commercial high-speed camera operating at 10 000 fps. The hereby work therefore focuses on the instrumentation-related automation efforts as the general method and clinical application have been reported earlier [Hurth et al., J. Appl. Phys. 110, 034701 (2011)]. In addition, we validate the performance of the automated setup with the calibration for viscosity measurements using water/glycerol standard solutions and the determination of the viscosity of an “unknown” solution of hydroxyethyl cellulose.

  20. Evaluation of rotational set-up errors in patients with thoracic neoplasms

    International Nuclear Information System (INIS)

    Wang Yanyang; Fu Xiaolong; Xia Bing; Fan Min; Yang Huanjun; Ren Jun; Xu Zhiyong; Jiang Guoliang

    2010-01-01

    Objective: To assess the rotational set-up errors in patients with thoracic neoplasms. Methods: 224 kilovoltage cone-beam computed tomography (KVCBCT) scans from 20 thoracic tumor patients were evaluated retrospectively. All these patients were involved in the research of 'Evaluation of the residual set-up error for online kilovoltage cone-beam CT guided thoracic tumor radiation'. Rotational set-up errors, including pitch, roll and yaw, were calculated by 'aligning the KVCBCT with the planning CT, using the semi-automatic alignment method. Results: The average rotational set-up errors were -0.28 degree ±1.52 degree, 0.21 degree ± 0.91 degree and 0.27 degree ± 0.78 degree in the left-fight, superior-inferior and anterior-posterior axis, respectively. The maximal rotational errors of pitch, roll and yaw were 3.5 degree, 2.7 degree and 2.2 degree, respectively. After correction for translational set-up errors, no statistically significant changes in rotational error were observed. Conclusions: The rotational set-up errors in patients with thoracic neoplasms were all small in magnitude. Rotational errors may not change after the correction for translational set-up errors alone, which should be evaluated in a larger sample future. (authors)

  1. Single Machine Multi-product Capacitated Lotsizing with Sequence-dependent Setups

    OpenAIRE

    Almada-Lobo , Bernardo; Klabjan , Diego; Carravilla , Maria Antónia; Oliveira , Jose Fernando

    2007-01-01

    Abstract In production planning in the glass container industry, machine dependent setup times and costs are incurred for switchovers from one product to another. The resulting multi-item capacitated lot sizing problem has sequence-dependent setup times and costs. We present two novel linear mixed integer programming formulations for this problem, incorporating all the necessary features of setup carryovers. The compact formulation has polynomially many constraints, while, on the o...

  2. Inter-treatment compensation of treatment setup variation to enhance the radiotherapeutic ratio

    International Nuclear Information System (INIS)

    Di, Yan; John, Wong; Michalski, Jeff; Pan, Cheng; Frazier, Arthur; Bosch, Walter; Martinez, Alvaro

    1995-01-01

    Purpose: In radiotherapy, treatment setup error has been one of the major causes of dose variation in the treated volume. With the data acquired from on-line electronic portal imaging, it is now possible not only to adjust the patient setup, but also to modify the treatment plan during the course of clinical treatment based on the setup error measured for each individual patient. In this work, daily clinical portal images were retrospectively analyzed to study (1) the number of initial daily portal images required to give adequate prediction of the systematic and random deviations of treatment setup, and (2) the potential therapeutic gain when the inter-treatment planning modification was established using the setup error of each individual patient. Methods and Materials: Only those patients whose treatment positions had not been adjusted during the course of treatment were selected for the retrospective study. Daily portal images of 27 lung, 25 pelvis, and 12 head and neck (h and n) cancer patients were obtained from two independent clinics with similar setup procedures. The anterior-to-posterior field was analyzed for the pelvis and lung treatments, and the right lateral field for the h and n treatments. Between 13 to 30 daily portal images were acquired for each patient and were analyzed using a 2D alignment tool. Systematic and random deviations of the treatment setup were calculated for each individual patient. The statistical confidence on the convergence of both systematic and random deviations with time were tested to determine the number of initial daily portal images needed to predict these deviations. In addition, a mean deviation for each site was also calculated using the setup errors from all patients. Two treatment planning schemes were simulated to evaluate margin design and prescription dose adjustment. Therapeutic scores were quantified in terms of tumor control probability (TCP) and normal tissue complication probability (NTCP). In the first

  3. The current status of the MASHA setup

    Science.gov (United States)

    Vedeneev, V. Yu.; Rodin, A. M.; Krupa, L.; Belozerov, A. V.; Chernysheva, E. V.; Dmitriev, S. N.; Gulyaev, A. V.; Gulyaeva, A. V.; Kamas, D.; Kliman, J.; Komarov, A. B.; Motycak, S.; Novoselov, A. S.; Salamatin, V. S.; Stepantsov, S. V.; Podshibyakin, A. V.; Yukhimchuk, S. A.; Granja, C.; Pospisil, S.

    2017-11-01

    The MASHA setup designed as the mass-separator with the resolving power of about 1700, which allows mass identification of superheavy nuclides is described. The setup uses solid ISOL (Isotope Separation On-Line) method. In the present article the upgrade of some parts of MASHA are described: target box (rotating target + hot catcher), ion source based on electron cyclotron resonance, data acquisition, beam diagnostics and control systems. The upgrade is undertaken in order to increase the total separation efficiency, reduce the separation time, of the installation and working stability and make possible continuous measurements at high beam currents. Ion source efficiency was measured in autonomous regime with using calibrated gas leaks of Kr and Xe injected directly to ion source. Some results of the first experiments for production of radon isotopes using the multi-nucleon transfer reaction 48Ca+242Pu are described in the present article. The using of TIMEPIX detector with MASHA setup for neutron-rich Rn isotopes identification is also described.

  4. The current status of the MASHA setup

    International Nuclear Information System (INIS)

    Vedeneev, V. Yu.; Rodin, A. M.; Krupa, L.; Belozerov, A. V.; Chernysheva, E. V.; Dmitriev, S. N.; Gulyaev, A. V.; Gulyaeva, A. V.; Kamas, D.; Kliman, J.; Komarov, A. B.; Motycak, S.; Novoselov, A. S.; Salamatin, V. S.; Stepantsov, S. V.; Podshibyakin, A. V.; Yukhimchuk, S. A.; Granja, C.; Pospisil, S.

    2017-01-01

    The MASHA setup designed as the mass-separator with the resolving power of about 1700, which allows mass identification of superheavy nuclides is described. The setup uses solid ISOL (Isotope Separation On-Line) method. In the present article the upgrade of some parts of MASHA are described: target box (rotating target + hot catcher), ion source based on electron cyclotron resonance, data acquisition, beam diagnostics and control systems. The upgrade is undertaken in order to increase the total separation efficiency, reduce the separation time, of the installation and working stability and make possible continuous measurements at high beam currents. Ion source efficiency was measured in autonomous regime with using calibrated gas leaks of Kr and Xe injected directly to ion source. Some results of the first experiments for production of radon isotopes using the multi-nucleon transfer reaction "4"8Ca+"2"4"2Pu are described in the present article. The using of TIMEPIX detector with MASHA setup for neutron-rich Rn isotopes identification is also described.

  5. The current status of the MASHA setup

    Energy Technology Data Exchange (ETDEWEB)

    Vedeneev, V. Yu., E-mail: vvedeneyev@gmail.com; Rodin, A. M.; Krupa, L.; Belozerov, A. V.; Chernysheva, E. V.; Dmitriev, S. N.; Gulyaev, A. V.; Gulyaeva, A. V.; Kamas, D. [Joint Institute for Nuclear Research, Flerov Laboratory of Nuclear Reactions (Russian Federation); Kliman, J. [Slovak Academy of Sciences, Institute of Physics (Slovakia); Komarov, A. B.; Motycak, S.; Novoselov, A. S.; Salamatin, V. S.; Stepantsov, S. V.; Podshibyakin, A. V.; Yukhimchuk, S. A. [Joint Institute for Nuclear Research, Flerov Laboratory of Nuclear Reactions (Russian Federation); Granja, C.; Pospisil, S. [Czech Technical University in Prague, Institute of Experimental and Applied Physics (Czech Republic)

    2017-11-15

    The MASHA setup designed as the mass-separator with the resolving power of about 1700, which allows mass identification of superheavy nuclides is described. The setup uses solid ISOL (Isotope Separation On-Line) method. In the present article the upgrade of some parts of MASHA are described: target box (rotating target + hot catcher), ion source based on electron cyclotron resonance, data acquisition, beam diagnostics and control systems. The upgrade is undertaken in order to increase the total separation efficiency, reduce the separation time, of the installation and working stability and make possible continuous measurements at high beam currents. Ion source efficiency was measured in autonomous regime with using calibrated gas leaks of Kr and Xe injected directly to ion source. Some results of the first experiments for production of radon isotopes using the multi-nucleon transfer reaction {sup 48}Ca+{sup 242}Pu are described in the present article. The using of TIMEPIX detector with MASHA setup for neutron-rich Rn isotopes identification is also described.

  6. The dose distribution and DVH change analysis wing to effect of the patient setup error

    International Nuclear Information System (INIS)

    Kim, Kyung Tae; Ju, Sang Gyu; Ahn, Jae Hong; Park, Young Hwan

    2004-01-01

    The setup error due to the patient and the staff from radiation treatment as the reason which is important the treatment record could be decided is a possibility of effect. The SET-UP ERROR of the patient analyzes the effect of dose distribution and DVH from radiation treatment of the patient. This test uses human phantom and when C-T scan doing, It rotated the Left direction of the human phantom and it made SET-UP ERROR, Standard plan and 3 mm, 5 mm, 7 mm, 10 mm, 15 mm, 20 mm with to distinguish, it made the C-T scan error. With the result, The SET-UP ERROR got each C-T image Using RTP equipment It used the plan which is used generally from clinical - Box plan, 3 Dimension plan( identical angle 5beam plan) Also, ( CTV+1cm margin, CTV+0.5cm margin, CTV+0.3,cm margin = PTV) it distinguished the standard plan and each set-up error plan and the plan used a dose distribution and the DVH and it analyzed. The Box 4 the plan and 3 Dimension plan which it bites it got similar an dose distribution and DVH in 3 mm, 5 mm From rotation error and Rectilinear movement (0%-2%). Rotation error and rectilinear error 7 mm, 10 mm, 15 mm, 20 mm appeared effect it will go mad to a enough change in treatment (2%-11%) The diminishes the effect of the SET-UP ERROR must reduce move with tension of the patient Also, we are important accessory development and the supply that it reducing of reproducibility and the move.

  7. X-ray fluorescence (XRF) set-up with a low power X-ray tube

    International Nuclear Information System (INIS)

    Gupta, Sheenu; Deep, Kanan; Jain, Lalita; Ansari, M.A.; Mittal, Vijay Kumar; Mittal, Raj

    2010-01-01

    The X-ray fluorescence set-up with a 100 W X-ray tube comprises a computer controlled system developed for remote operation and monitoring of tube and an adjustable stable 3D arrangement to procure variable excitation energies with low scattered background. The system was tested at different filament currents/anode voltages. The MDL of the set-up at 0.05-1.00 mA/4-12 kV is found ∼(1-100) ppm for K and L excitations and ∼(200-700) ppm for M excitations of elements and improves with filament current and anode voltage. Moreover, L measurements for Sm and Eu at five K X-ray energies of elements(Z=29-40) and analytical determination in some synthetic samples were undertaken.

  8. Integration of micro milling highspeed spindle on a microEDM-milling machine set-up

    DEFF Research Database (Denmark)

    De Grave, Arnaud; Hansen, Hans Nørgaard; Andolfatto, Loic

    2009-01-01

    In order to cope with repositioning errors and to combine the fast removal rate of micro milling with the precision and small feature size achievable with micro EDM milling, a hybrid micro-milling and micro-EDM milling centre was built and tested. The aim was to build an affordable set-up, easy...... by micro milling. Examples of test parts are shown and used as an experimental validation....

  9. New attacks on Wi-Fi Protected Setup

    OpenAIRE

    Hamed Mohtadi; Alireza Rahimi

    2015-01-01

    Wi-Fi Protected Setup (WPS) is a network security standard that is used to secure networks in home and office, introduced in 2006 by the Wi-Fi Alliance. It provides easier configuration setup and is used in almost all recent Wi-Fi devices. In this paper we propose two attacks on this standard. The first attack is an offline brute force attack that uses imbalance on registration protocol. This attack needs user action, but it is more efficient than previous attacks. The second attack uses weak...

  10. Single ion hit detection set-up for the Zagreb ion microprobe

    Science.gov (United States)

    Smith, R. W.; Karlušić, M.; Jakšić, M.

    2012-04-01

    Irradiation of materials by heavy ions accelerated in MV tandem accelerators may lead to the production of latent ion tracks in many insulators and semiconductors. If irradiation is performed in a high resolution microprobe facility, ion tracks can be ordered by submicrometer positioning precision. However, full control of the ion track positioning can only be achieved by a reliable ion hit detection system that should provide a trigger signal irrespectively of the type and thickness of the material being irradiated. The most useful process that can be utilised for this purpose is emission of secondary electrons from the sample surface that follows the ion impact. The status report of the set-up presented here is based on the use of a channel electron multiplier (CEM) detector mounted on an interchangable sample holder that is inserted into the chamber in a close geometry along with the sample to be irradiated. The set-up has been tested at the Zagreb ion microprobe for different ions and energies, as well as different geometrical arrangements. For energies of heavy ions below 1 MeV/amu, results show that efficient (100%) control of ion impact can be achieved only for ions heavier than silicon. The successful use of the set-up is demonstrated by production of ordered single ion tracks in a polycarbonate film and by monitoring fluence during ion microbeam patterning of Foturan glass.

  11. Broadband Fan Noise Prediction System for Turbofan Engines. Volume 1; Setup_BFaNS User's Manual and Developer's Guide

    Science.gov (United States)

    Morin, Bruce L.

    2010-01-01

    Pratt & Whitney has developed a Broadband Fan Noise Prediction System (BFaNS) for turbofan engines. This system computes the noise generated by turbulence impinging on the leading edges of the fan and fan exit guide vane, and noise generated by boundary-layer turbulence passing over the fan trailing edge. BFaNS has been validated on three fan rigs that were tested during the NASA Advanced Subsonic Technology Program (AST). The predicted noise spectra agreed well with measured data. The predicted effects of fan speed, vane count, and vane sweep also agreed well with measurements. The noise prediction system consists of two computer programs: Setup_BFaNS and BFaNS. Setup_BFaNS converts user-specified geometry and flow-field information into a BFaNS input file. From this input file, BFaNS computes the inlet and aft broadband sound power spectra generated by the fan and FEGV. The output file from BFaNS contains the inlet, aft and total sound power spectra from each noise source. This report is the first volume of a three-volume set documenting the Broadband Fan Noise Prediction System: Volume 1: Setup_BFaNS User s Manual and Developer s Guide; Volume 2: BFaNS User's Manual and Developer s Guide; and Volume 3: Validation and Test Cases. The present volume begins with an overview of the Broadband Fan Noise Prediction System, followed by step-by-step instructions for installing and running Setup_BFaNS. It concludes with technical documentation of the Setup_BFaNS computer program.

  12. Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom

    CERN Document Server

    Mainaud Durand, H; Griffet, S; Kemppinen, J; Leuxe, R; Sosin, M

    2011-01-01

    The CLIC main beam quadrupoles need to be prealigned within 17 um rms with respect to a straight reference line along a sliding window of 200 m. A readjustment system based on eccentric cam movers, which will provide stiffness to the support assembly, is being studied. The cam movers were qualified on a 1 degree of freedom (DOF) test setup, where a repeatability of adjustment below 1um was measured along their whole range. This paper presents the 5 DOF mock-up, built for the validation of the eccentric cam movers, as well as the first results of tests carried out: resolution of displacement along the whole range, measurements of the support eigenfrequencies.

  13. A novel method to correct for pitch and yaw patient setup errors in helical tomotherapy

    International Nuclear Information System (INIS)

    Boswell, Sarah A.; Jeraj, Robert; Ruchala, Kenneth J.; Olivera, Gustavo H.; Jaradat, Hazim A.; James, Joshua A.; Gutierrez, Alonso; Pearson, Dave; Frank, Gary; Mackie, T. Rock

    2005-01-01

    An accurate means of determining and correcting for daily patient setup errors is important to the cancer outcome in radiotherapy. While many tools have been developed to detect setup errors, difficulty may arise in accurately adjusting the patient to account for the rotational error components. A novel, automated method to correct for rotational patient setup errors in helical tomotherapy is proposed for a treatment couch that is restricted to motion along translational axes. In tomotherapy, only a narrow superior/inferior section of the target receives a dose at any instant, thus rotations in the sagittal and coronal planes may be approximately corrected for by very slow continuous couch motion in a direction perpendicular to the scanning direction. Results from proof-of-principle tests indicate that the method improves the accuracy of treatment delivery, especially for long and narrow targets. Rotational corrections about an axis perpendicular to the transverse plane continue to be implemented easily in tomotherapy by adjustment of the initial gantry angle

  14. Impact of different setup approaches in image-guided radiotherapy as primary treatment for prostate cancer. A study of 2940 setup deviations in 980 MVCTs

    International Nuclear Information System (INIS)

    Schiller, Kilian; Specht, Hanno; Kampfer, Severin; Duma, Marciana Nona; Petrucci, Alessia; Geinitz, Hans; Schuster, Tibor

    2014-01-01

    The goal of this study was to assess the impact of different setup approaches in image-guided radiotherapy (IMRT) of the prostatic gland. In all, 28 patients with prostate cancer were enrolled in this study. After the placement of an endorectal balloon, the planning target volume (PTV) was treated to a dose of 70 Gy in 35 fractions. A simultaneously integrated boost (SIB) of 76 Gy (2.17 Gy per fraction and per day) was delivered to a smaller target volume. All patients underwent daily prostate-aligned IGRT by megavoltage CT (MVCT). Retrospectively, three different setup approaches were evaluated by comparison to the prostate alignment: setup by skin alignment, endorectal balloon alignment, and automatic registration by bones. A total of 2,940 setup deviations were analyzed in 980 fractions. Compared to prostate alignment, skin mark alignment was associated with substantial displacements, which were ≥ 8 mm in 13 %, 5 %, and 44 % of all fractions in the lateral, longitudinal, and vertical directions, respectively. Endorectal balloon alignment yielded displacements ≥ 8 mm in 3 %, 19 %, and 1 % of all setups; and ≥ 3 mm in 27 %, 58 %, and 18 % of all fractions, respectively. For bone matching, the values were 1 %, 1 %, and 2 % and 3 %, 11 %, and 34 %, respectively. For prostate radiotherapy, setup by skin marks alone is inappropriate for patient positioning due to the fact that, during almost half of the fractions, parts of the prostate would not be targeted successfully with an 8-mm safety margin. Bone matching performs better but not sufficiently for safety margins ≤ 3 mm. Endorectal balloon matching can be combined with bone alignment to increase accuracy in the vertical direction when prostate-based setup is not available. Daily prostate alignment remains the gold standard for high-precision radiotherapy with small safety margins. (orig.) [de

  15. Broadband short pulse measurement by autocorrelation with a sum-frequency generation set-up

    International Nuclear Information System (INIS)

    Glotin, F.; Jaroszynski, D.; Marcouille, O.

    1995-01-01

    Previous spectral and laser pulse length measurements carried out on the CLIO FEL at wavelength λ=8.5 μm suggested that very short light pulses could be generated, about 500 fs wide (FWHM). For these measurements a Michelson interferometer with a Te crystal, as a non-linear detector, was used as a second order autocorrelation device. More recent measurements in similar conditions have confirmed that the laser pulses observed are indeed single: they are not followed by other pulses distant by the slippage length Nλ. As the single micropulse length is likely to depend on the slippage, more measurements at different wavelengths would be useful. This is not directly possible with our actual interferometer set-up, based on a phase-matched non-linear crystal. However, we can use the broadband non-linear medium provided by one of our users' experiments: Sum-Frequency Generation over surfaces. With such autocorrelation set-up, interference fringes are no more visible, but this is largely compensated by the frequency range provided. First tests at 8 μm have already been performed to validate the technic, leading to results similar to those obtained with our previous Michelson set-up

  16. Automated PCR setup for forensic casework samples using the Normalization Wizard and PCR Setup robotic methods.

    Science.gov (United States)

    Greenspoon, S A; Sykes, K L V; Ban, J D; Pollard, A; Baisden, M; Farr, M; Graham, N; Collins, B L; Green, M M; Christenson, C C

    2006-12-20

    Human genome, pharmaceutical and research laboratories have long enjoyed the application of robotics to performing repetitive laboratory tasks. However, the utilization of robotics in forensic laboratories for processing casework samples is relatively new and poses particular challenges. Since the quantity and quality (a mixture versus a single source sample, the level of degradation, the presence of PCR inhibitors) of the DNA contained within a casework sample is unknown, particular attention must be paid to procedural susceptibility to contamination, as well as DNA yield, especially as it pertains to samples with little biological material. The Virginia Department of Forensic Science (VDFS) has successfully automated forensic casework DNA extraction utilizing the DNA IQ(trade mark) System in conjunction with the Biomek 2000 Automation Workstation. Human DNA quantitation is also performed in a near complete automated fashion utilizing the AluQuant Human DNA Quantitation System and the Biomek 2000 Automation Workstation. Recently, the PCR setup for casework samples has been automated, employing the Biomek 2000 Automation Workstation and Normalization Wizard, Genetic Identity version, which utilizes the quantitation data, imported into the software, to create a customized automated method for DNA dilution, unique to that plate of DNA samples. The PCR Setup software method, used in conjunction with the Normalization Wizard method and written for the Biomek 2000, functions to mix the diluted DNA samples, transfer the PCR master mix, and transfer the diluted DNA samples to PCR amplification tubes. Once the process is complete, the DNA extracts, still on the deck of the robot in PCR amplification strip tubes, are transferred to pre-labeled 1.5 mL tubes for long-term storage using an automated method. The automation of these steps in the process of forensic DNA casework analysis has been accomplished by performing extensive optimization, validation and testing of the

  17. Fracture Testing of Honeycomb Core Sandwich Composites Using the DCB-UBM Test

    DEFF Research Database (Denmark)

    Saseendran, Vishnu; Berggreen, Christian; Carlsson, Leif A.

    2015-01-01

    of Linear Elastic Fracture Mechanics (LEFM). The Double Cantilever Beam subjected to Uneven Bending Moments (DCB-UBM) test set-up, which was introduced by Sørensen.et.al [1], circumvents any dependency of the pre-crack length in calculation of Gc. The new test setup is based on rotary actuators which...

  18. A simple Lissajous curves experimental setup

    Science.gov (United States)

    Şahin Kızılcık, Hasan; Damlı, Volkan

    2018-05-01

    The aim of this study is to develop an experimental setup to produce Lissajous curves. The setup was made using a smartphone, a powered speaker (computer speaker), a balloon, a laser pointer and a piece of mirror. Lissajous curves are formed as follows: a piece of mirror is attached to a balloon. The balloon is vibrated with the sound signal provided by the speaker that is connected to a smartphone. The laser beam is reflected off the mirror and the reflection is shaped as a Lissajous curve. Because of the intersection of two frequencies (frequency of the sound signal and natural vibration frequency of the balloon), these curves are formed. They can be used to measure the ratio of frequencies.

  19. Setup Time Reduction On Solder Paste Printing Machine – A Case Study

    Directory of Open Access Journals (Sweden)

    Rajesh Dhake

    2013-06-01

    Full Text Available Lean manufacturing envisages the reduction of the seven deadly wastes referred to as MUDA. Setup time forms a major component of the equipment downtime. It leads to lower machine utilization and restricts the output and product variety. This necessitates the requirement for quick setups. Single Minute Exchange of Die philosophy (a lean manufacturing tool here after referred as “SMED” is one of the important tool which aims at quick setups driving smaller lot sizes, lower production costs, improve productivity in terms of increased output, increased utilization of machine and labor hours, make additional capacity available (often at bottleneck resources, reduce scrap and rework, and increase flexibility[3]. This paper focuses on the application of Single Minute Exchange of Die[1] and Quick Changeover Philosophy[2] for reducing setup time on Solder Past Printing Machine (bottleneck machine in a electronic speedo-cluster manufacturing company. The four step SMED philosophy was adopted to effect reduction in setup time. The initial step was gathering information about the present setup times and its proportion to the total productive time. A detailed video based time study of setup activities was done to classify them into external and internal setup activities in terms of their need (i.e. preparation, replacement or adjustment, time taken and the way these could be reduced, simplified or eliminated. The improvements effected were of three categories viz., mechanical, procedural and organizational. The paper concludes by comparing the present and proposed (implemented methods of setup procedures.

  20. Couch height–based patient setup for abdominal radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ohira, Shingo [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita (Japan); Ueda, Yoshihiro [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita (Japan); Nishiyama, Kinji [Department of Radiation Oncology, Yao Municipal Hospital, Yao (Japan); Miyazaki, Masayoshi; Isono, Masaru; Tsujii, Katsutomo [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Takashina, Masaaki; Koizumi, Masahiko [Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita (Japan); Kawanabe, Kiyoto [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Teshima, Teruki, E-mail: teshima-te@mc.pref.osaka.jp [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan)

    2016-04-01

    There are 2 methods commonly used for patient positioning in the anterior-posterior (A-P) direction: one is the skin mark patient setup method (SMPS) and the other is the couch height–based patient setup method (CHPS). This study compared the setup accuracy of these 2 methods for abdominal radiation therapy. The enrollment for this study comprised 23 patients with pancreatic cancer. For treatments (539 sessions), patients were set up by using isocenter skin marks and thereafter treatment couch was shifted so that the distance between the isocenter and the upper side of the treatment couch was equal to that indicated on the computed tomographic (CT) image. Setup deviation in the A-P direction for CHPS was measured by matching the spine of the digitally reconstructed radiograph (DRR) of a lateral beam at simulation with that of the corresponding time-integrated electronic portal image. For SMPS with no correction (SMPS/NC), setup deviation was calculated based on the couch-level difference between SMPS and CHPS. SMPS/NC was corrected using 2 off-line correction protocols: no action level (SMPS/NAL) and extended NAL (SMPS/eNAL) protocols. Margins to compensate for deviations were calculated using the Stroom formula. A-P deviation > 5 mm was observed in 17% of SMPS/NC, 4% of SMPS/NAL, and 4% of SMPS/eNAL sessions but only in one CHPS session. For SMPS/NC, 7 patients (30%) showed deviations at an increasing rate of > 0.1 mm/fraction, but for CHPS, no such trend was observed. The standard deviations (SDs) of systematic error (Σ) were 2.6, 1.4, 0.6, and 0.8 mm and the root mean squares of random error (σ) were 2.1, 2.6, 2.7, and 0.9 mm for SMPS/NC, SMPS/NAL, SMPS/eNAL, and CHPS, respectively. Margins to compensate for the deviations were wide for SMPS/NC (6.7 mm), smaller for SMPS/NAL (4.6 mm) and SMPS/eNAL (3.1 mm), and smallest for CHPS (2.2 mm). Achieving better setup with smaller margins, CHPS appears to be a reproducible method for abdominal patient setup.

  1. On the measurement of high-energetic neutrinos with the IceCube neutrino telescope and with acoustic detection methods

    International Nuclear Information System (INIS)

    Schunck, Matthias

    2011-01-01

    In this thesis, two subjects have been addressed to enhance the detection of astrophysical neutrinos with the existing IceCube neutrino telescope as well as to explore new detection methods, namely the acoustic detection. In the first part of this thesis, the determination of the acoustic attenuation length in South-Pole ice is presented. This is part of a feasibility study to investigate the acoustic neutrino detection as a possibility to enhance the detection of the highest-energy neutrinos. For this, the acoustic properties of the ice have to be known, and the South-Pole Acoustic Test Setup (SPATS) has been built to determine these. The attenuation length is determined using in-situ measurements with SPATS and a retrievable transmitter (pinger), which was deployed in a depth between 190 and 500 m into the water-filled drilling holes. Even though, the unknown angular-dependent sensitivities of the SPATS sensor channels cannot be avoided and are considered as the dominant systematic effect for these measurements. In this thesis, the acoustic attenuation length is calculated by comparing the energy contents of the pinger pulses recorded by the various SPATS sensor channels for different distances between the pinger and the respective channel. The energy was calculated from the Fourier spectra of the pinger pulses for a frequency range between 5 and 35 kHz. The attenuation coefficient is calculated for each channel individually and the weighted mean over the distribution of all considered channels leads to an attenuation length of 264 +52 -37 m. The dependence of the attenuation on both depth and frequency has been investigated, showing no indications for either. In the second part, a new event reconstruction method based on a Top-Down approach is presented. The method has been implemented for the IC40 detector and applied to the muon energy reconstruction. The Top-Down method is based on the direct comparison of single measured events with a large sample of

  2. On the measurement of high-energetic neutrinos with the IceCube neutrino telescope and with acoustic detection methods

    Energy Technology Data Exchange (ETDEWEB)

    Schunck, Matthias

    2011-10-07

    In this thesis, two subjects have been addressed to enhance the detection of astrophysical neutrinos with the existing IceCube neutrino telescope as well as to explore new detection methods, namely the acoustic detection. In the first part of this thesis, the determination of the acoustic attenuation length in South-Pole ice is presented. This is part of a feasibility study to investigate the acoustic neutrino detection as a possibility to enhance the detection of the highest-energy neutrinos. For this, the acoustic properties of the ice have to be known, and the South-Pole Acoustic Test Setup (SPATS) has been built to determine these. The attenuation length is determined using in-situ measurements with SPATS and a retrievable transmitter (pinger), which was deployed in a depth between 190 and 500 m into the water-filled drilling holes. Even though, the unknown angular-dependent sensitivities of the SPATS sensor channels cannot be avoided and are considered as the dominant systematic effect for these measurements. In this thesis, the acoustic attenuation length is calculated by comparing the energy contents of the pinger pulses recorded by the various SPATS sensor channels for different distances between the pinger and the respective channel. The energy was calculated from the Fourier spectra of the pinger pulses for a frequency range between 5 and 35 kHz. The attenuation coefficient is calculated for each channel individually and the weighted mean over the distribution of all considered channels leads to an attenuation length of 264{sup +52} {sub -37} m. The dependence of the attenuation on both depth and frequency has been investigated, showing no indications for either. In the second part, a new event reconstruction method based on a Top-Down approach is presented. The method has been implemented for the IC40 detector and applied to the muon energy reconstruction. The Top-Down method is based on the direct comparison of single measured events with a large sample

  3. Investigation of self healing behaviour of asphalt mixes using beam on elastic foundation setup

    NARCIS (Netherlands)

    Qiu, J.; Molenaar, A.A.A.; Van de Ven, M.F.C.; Wu, S.; Yu, J.

    2012-01-01

    Self healing of asphalt mixes is known for more than four decades. However, it is a complex phenomenon which depends on the duration of the rest period, temperature, crack size, etc. In order to quantify the self healing behaviour of asphalt mixes, a test setup was proposed in this research using an

  4. Comparison of two setups for induction heating in injection molding

    DEFF Research Database (Denmark)

    Menotti, Stefano; Hansen, Hans Nørgaard; Bissacco, Giuliano

    2015-01-01

    To eliminate defects and improve the quality of molded parts, increasing the mold temperature is one of the applicable solutions. A high mold temperature can increase the path flow of the polymer inside the cavity allowing reduction of the number of injection points, reduction of part thickness......, and moulding of smaller and more complex geometries. The last two aspects are very important in micro injection molding. In this paper, a new embedded induction heating system is proposed and validated and two different coil setups were tested and compared. An experimental investigation was performed based...

  5. Experimental setup for Single Event Effects at the São Paulo 8UD Pelletron Accelerator

    Science.gov (United States)

    Aguiar, V. A. P.; Added, N.; Medina, N. H.; Macchione, E. L. A.; Tabacniks, M. H.; Aguirre, F. R.; Silveira, M. A. G.; Santos, R. B. B.; Seixas, L. E.

    2014-08-01

    In this work we present an experimental setup mounted in one of the beam lines at the São Paulo 8UD Pelletron Accelerator in order to study Single Event Effects in electronic devices. The basic idea is to use elastic scattering collisions to achieve a low-flux with a high-uniformity ion beam to irradiate several devices. 12C, 16O, 28Si, 35Cl and 63Cu beams were used to test the experimental setup. In this system it is possible to use efficiently LET values of 17 MeV/mg/cm2 for an external beam arrangement and up to 32 MeV/mg/cm2 for in-vacuum irradiation.

  6. Measurement and analysis of the thoracic patient setup deviations in routine radiotherapy

    International Nuclear Information System (INIS)

    Jia Mingxuan; Zou Huawei; Wu Rong; Sun Jian; Dong Xiaoqi

    2003-01-01

    Objective: To determine the magnitude of the setup deviations of the thoracic patients in routine radiotherapy. Methods: Altogether 408 films for 21 thoracic patients were recorded using the electronic portal imaging device (EPID), and comparison with reference CT simulator digitally-reconstructed radiograph (DRR) for anterior-posterior fields was performed. The deviation of setup for 21 patients in the left-right (RL), superior-inferior (SI) directions and rotation about the anterior-posterior (AP) axis were measured and analyzed. Results: Without immobilization device, the mean translational and rotational setup deviations were (0.7±3.1) mm and (1.5±4.1) mm in the RL and SI directions, respectively, and (0.3±2.4) degree about AP axis. With immobilization device, the mean translational and rotational setup deviations were (0.5±2.4) mm and (0.8±2.7) mm in the RL and SI directions respectively, and (0.2±1.6) degree about AP axis. Conclusion: The setup deviations in thoracic patients irradiation may be reduced with the use of the immobilization device. The setup deviation in the SI direction is greater than that in the RL direction. The setup deviations are mainly random errors

  7. Set-up for steam generator tube bundle washing after explosion expanding the tubes

    International Nuclear Information System (INIS)

    Osipov, S.I.; Kal'nin, A.Ya.; Mazanenko, M.F.

    1985-01-01

    Set-up for steam generator tube bundle washing after the explosion expanding of tubes is described. Washing is accomplished by distillate. Steam is added to distillate for heating, and compersed air for preventing hydraulic shock. The set-up is equiped by control equipment. Set-up performances are presented. Time for one steam generator washing constitutes 8-12 h. High economic efficiency is realized due to the set-up introduction

  8. Water level effects on breaking wave setup for Pacific Island fringing reefs

    Science.gov (United States)

    Becker, J. M.; Merrifield, M. A.; Ford, M.

    2014-02-01

    The effects of water level variations on breaking wave setup over fringing reefs are assessed using field measurements obtained at three study sites in the Republic of the Marshall Islands and the Mariana Islands in the western tropical Pacific Ocean. At each site, reef flat setup varies over the tidal range with weaker setup at high tide and stronger setup at low tide for a given incident wave height. The observed water level dependence is interpreted in the context of radiation stress gradients specified by an idealized point break model generalized for nonnormally incident waves. The tidally varying setup is due in part to depth-limited wave heights on the reef flat, as anticipated from previous reef studies, but also to tidally dependent breaking on the reef face. The tidal dependence of the breaking is interpreted in the context of the point break model in terms of a tidally varying wave height to water depth ratio at breaking. Implications for predictions of wave-driven setup at reef-fringed island shorelines are discussed.

  9. VITEX 2016 : Evaluation of learning objectives and exercise set-up

    NARCIS (Netherlands)

    Rijk, R. van; Stubbé-Alberts, H.E.

    2016-01-01

    To strengthen awareness of the need for cooperation, between public and private partners, and between countries, a new exercise set-up was developed. The VITEX exercise set-up is a table top exercise that aims to bring relevant networks together, and supports cooperation and collaboration between

  10. Why IV Setup for Stream Ciphers is Difficult

    DEFF Research Database (Denmark)

    Zenner, Erik

    2007-01-01

    In recent years, the initialization vector (IV) setup has proven to be the most vulnerable point when designing secure stream ciphers. In this paper, we take a look at possible reasons why this is the case, identifying numerous open research problems in cryptography.......In recent years, the initialization vector (IV) setup has proven to be the most vulnerable point when designing secure stream ciphers. In this paper, we take a look at possible reasons why this is the case, identifying numerous open research problems in cryptography....

  11. On SIP Session setup delay for VoIP services over correlated fading channels

    DEFF Research Database (Denmark)

    Fathi, Hanane; Chakraborty, Shyam S.; Prasad, Ramjee

    2006-01-01

    In this paper, the session setup delay of the session initiation protocol (SIP) is studied. The transmissions on both the forward and reverse channel are assumed to experience Markovian errors. The session setup delay is evaluated for different transport protocols, and with the use of the radio...... link protocol (RLP). An adaptive retransmission timer is used to optimize SIP performances. Using numerical results, we find that SIP over user datagram protocol (UDP) instead of transport control protocol (TCP) can make the session setup up to 30% shorter. Also, RLP drastically reduces the session...... setup delay down to 4 to 5 s, even in environments with high frame error rates (10%) and significant correlation in the fading process (fDT=0.02). SIP is compared with its competitor H.323. SIP session setup delay with compressed messages outperforms H.323 session setup delay....

  12. Limets 2: a hot-cell test set-up for Liquid Metal Embrittlement (LME) studies in liquid lead alloys

    International Nuclear Information System (INIS)

    Van den Bosch, J.; Bosch, R.W.; Al Mazouzi, A.

    2008-01-01

    Full text of publication follows. In the nuclear energy sector one of the main candidate designs for the accelerator driven system (ADS) uses liquid lead or lead bismuth eutectic both as a coolant and as spallation target. In the fusion community liquid lead lithium eutectic is considered as a possible coolant for the blanket and as a tritium source. Therefore the candidate materials for such structural components should not only comply with the operating conditions but in addition need to guarantee chemical and physical integrity when coming into contact with the lead alloys. The latter phenomena can be manifested in terms of erosion/corrosion. and/or of the so called liquid metal embrittlement (LME). Thus the susceptibility to LME of the structural materials under consideration to be used in such applications should be investigated in contact with the various lead alloys. LME, if occurring in any solid metal/liquid meta] couple, is likely to increase with irradiation hardening as localised stresses and crack initiations can promote it. To investigate the mechanical response of irradiated materials in contact with a liquid metal under representative conditions, a dedicated testing facility has recently been developed and built at our centre. It consists of an instrumented hot cell. equipped with a testing machine that allows mechanical testing of active materials in contact with active liquid lead lithium and liquid lead bismuth under well controlled chemistry conditions. The specificity of the installation is to handle highly activated and contaminated samples. Also a dedicated dismantling set-up has been developed that allows to retrieve the samples from the irradiation rig without any supplementary damage. In this presentation we will focus on the technical design of this new installation, its special features that have been developed to allow testing in a hot environment and the modifications and actions that have been taken to allow testing in liquid lead

  13. A new tribological experimental setup to study confined and sheared monolayers.

    Science.gov (United States)

    Fu, L; Favier, D; Charitat, T; Gauthier, C; Rubin, A

    2016-03-01

    We have developed an original experimental setup, coupling tribology, and velocimetry experiments together with a direct visualization of the contact. The significant interest of the setup is to measure simultaneously the apparent friction coefficient and the velocity of confined layers down to molecular scale. The major challenge of this experimental coupling is to catch information on a nanometer-thick sheared zone confined between a rigid spherical indenter of millimetric radius sliding on a flat surface at constant speed. In order to demonstrate the accuracy of this setup to investigate nanometer-scale sliding layers, we studied a model lipid monolayer deposited on glass slides. It shows that our experimental setup will, therefore, help to highlight the hydrodynamic of such sheared confined layers in lubrication, biolubrication, or friction on solid polymer.

  14. Infrared-Guided Patient Setup for Lung Cancer Patients

    International Nuclear Information System (INIS)

    Lyatskaya, Yulia; James, Steven; Killoran, Joseph H.; Soto, Ricardo; Mamon, Harvey J.; Chin, Lee; Allen, Aaron M.

    2008-01-01

    Purpose: To evaluate the utility of an infrared-guided patient setup (iGPS) system to reduce the uncertainties in the setup of lung cancer patients. Methods and Materials: A total of 15 patients were setup for lung irradiation using skin tattoos and lateral leveling marks. Daily electronic portal device images and iGPS marker locations were acquired and retrospectively reviewed. The iGPS-based shifts were compared with the daily electronic portal device image shifts using both the central axis iGPS marker and all five iGPS markers. For shift calculation using the five markers, rotational misalignment was included. The level of agreement between the iGPS and portal imaging to evaluate the setup was evaluated as the frequency of the shift difference in the range of 0-5 mm, 5-10 mm, and >10 mm. Results: Data were obtained for 450 treatment sessions for 15 patients. The difference in the isocenter shifts between the weekly vs. daily images was 0-5 mm in 42%, 5-10 mm in 30%, and >10 mm in 10% of the images. The shifts seen using the iGPS data were 0-5 mm in 81%, 5-10 mm in 14%, and >10 mm in 5%. Using only the central axis iGPS marker, the difference between the iGPS and portal images was 10 mm in 7% in the left-right direction and 73%, 18%, and 9% in the superoinferior direction, respectively. When all five iGPS markers were used, the disagreements between the iGPS and portal image shifts >10 mm were reduced from 7% to 2% in the left-right direction and 9% to 3% in the superoinferior direction. Larger reductions were also seen (e.g., a reduction from 50% to 0% in 1 patient). Conclusion: The daily iGPS-based shifts correlated well with the daily electronic portal device-based shifts. When patient movement has nonlinear rotational components, a combination of surface markers and portal images might be particularly beneficial to improve the setup for lung cancer patients

  15. Wideband MIMO Channel Capacity Analysis in Multiprobe Anechoic Chamber Setups

    DEFF Research Database (Denmark)

    Fan, Wei; Kyosti, Pekka; Nielsen, Jesper Ødum

    2016-01-01

    been used to determine the test area size for a limited number of probes. However, it is desirable that the test area size is defined in terms of data rate deviation of the simulated channel in the laboratory from that of the target channel model. This paper reports MIMO capacity analysis results...... for wideband spatio-temporal channel models, with emphasis on the impact of spatial correlation at the transmit (Tx) side, the channel model, and the spatial correlation at the Rx side on the capacity simulation accuracy. Simulation results show that the number of probes is irrelevant to capacity simulation......This paper discusses over the air (OTA) testing for multiple input multiple output (MIMO) capable terminals with emphasis on wideband MIMO channel capacity analysis in a multi-probe anechoic chamber setup. In the literature, the spatial correlation simulation accuracy at the receiver (Rx) side has...

  16. Experimental setup for Single Event Effects at the São Paulo 8UD Pelletron Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Aguiar, V.A.P. [Instituto de Física da Universidade de São Paulo, São Paulo, SP (Brazil); Added, N., E-mail: nemitala@if.usp.br [Instituto de Física da Universidade de São Paulo, São Paulo, SP (Brazil); Medina, N.H.; Macchione, E.L.A.; Tabacniks, M.H.; Aguirre, F.R. [Instituto de Física da Universidade de São Paulo, São Paulo, SP (Brazil); Silveira, M.A.G.; Santos, R.B.B. [Centro Universitário da FEI, São Bernardo do Campo, SP (Brazil); Seixas, L.E. [Centro de Tecnologia da Informação Renato Archer, Campinas, SP (Brazil)

    2014-08-01

    In this work we present an experimental setup mounted in one of the beam lines at the São Paulo 8UD Pelletron Accelerator in order to study Single Event Effects in electronic devices. The basic idea is to use elastic scattering collisions to achieve a low-flux with a high-uniformity ion beam to irradiate several devices. {sup 12}C, {sup 16}O, {sup 28}Si, {sup 35}Cl and {sup 63}Cu beams were used to test the experimental setup. In this system it is possible to use efficiently LET values of 17 MeV/mg/cm{sup 2} for an external beam arrangement and up to 32 MeV/mg/cm{sup 2} for in-vacuum irradiation.

  17. Influence of Daily Set-Up Errors on Dose Distribution During Pelvis Radiotherapy

    International Nuclear Information System (INIS)

    Kasabasic, M.; Ivkovic, A.; Faj, D.; Rajevac, V.; Sobat, H.; Jurkovic, S.

    2011-01-01

    An external beam radiotherapy (EBRT) using megavoltage beam of linear accelerator is usually the treatment of choice for the cancer patients. The goal of EBRT is to deliver the prescribed dose to the target volume, with as low as possible dose to the surrounding healthy tissue. A large number of procedures and different professions involved in radiotherapy process, uncertainty of equipment and daily patient set-up errors can cause a difference between the planned and delivered dose. We investigated a part of this difference caused by daily patient set-up errors. Daily set-up errors for 35 patients were measured. These set-up errors were simulated on 5 patients, using 3D treatment planning software XiO (CMS Inc., St. Louis, MO). The differences in dose distributions between the planned and shifted ''geometry'' were investigated. Additionally, an influence of the error on treatment plan selection was checked by analyzing the change in dose volume histograms, planning target volume conformity index (CI P TV) and homogeneity index (HI). Simulations showed that patient daily set-up errors can cause significant differences between the planned and actual dose distributions. Moreover, for some patients those errors could influence the choice of treatment plan since CI P TV fell under 97 %. Surprisingly, HI was not as sensitive as CI P TV on set-up errors. The results showed the need for minimizing daily set-up errors by quality assurance programme. (author)

  18. Testing Augmented Reality Systems for Spotting Sub-Surface Impurities

    DEFF Research Database (Denmark)

    Hald, Kasper; Rehm, Matthias; Moeslund, Thomas B.

    2018-01-01

    This paper describes setup and procedure for testing augmented reality systems for showing sub-surface positions of foreign elements in an opaque mass. The goal is it test four types of setup in terms of user accuracy and speed, the four setups being a head-mounted see-through display, an arm...

  19. Test Setup for Anechoic Room based MIMO OTA Testing of LTE Terminals

    DEFF Research Database (Denmark)

    Carreño, Xavier; Fan, Wei; Nielsen, Jesper Ødum

    2013-01-01

    introduced into, for example, LTE andWiMAX systems. The main purpose of this testing is to validate that the user equipment will have a good performance in real use. CTIA, 3GPP and COST are spending a big effort in standardizing the OTA testing procedure which is much more complex than similar SISO OTA...... the activities related to the MIMO OTA lab being built at Aalborg University (AAU), Denmark and the testing being performed....

  20. Development of an experiment for ultrahigh-precision g-factor measurements in a Penning-trap setup

    Energy Technology Data Exchange (ETDEWEB)

    Alonso Otamendi, J.

    2007-07-13

    This thesis is concerned with the design and construction of an experimental setup aiming to perform ultrahigh-precision g-factor measurements on a bound electron in highly-charged ions. The g-factor of a particle is a dimensionless constant which determines the strength of its interaction with a magnetic field. In the case of an electron bound to a highly-charged ion, it serves as one of the most stringent tests of bound-state quantum electrodynamics (BS-QED). The measurement is based on a triple-Penning-trap system and the continuous Stern-Gerlach effect. The first part of the thesis is devoted to the current knowledge on magnetic moments and motivates the techniques and experimental setup used during the work described. As a major challenge to overcome, the charge breeding of the ions is dealt with in detail, along with the solution found, based on a field-emission-point array. The tools included allow for the measurement of ionization cross-sections by electron impact. The last part of the thesis is dedicated to the design and operation of the triple-Penning-trap setup and the detection schemes implemented. At present, all the experimental setup for the production of highly-charged ions and the corresponding g-factor measurement is completely finalized, including the control system needed for the first measurement stages, so the ion-creation and charge-breeding processes will be the next steps to be taken. (orig.)

  1. Development of an experiment for ultrahigh-precision g-factor measurements in a Penning-trap setup

    International Nuclear Information System (INIS)

    Alonso Otamendi, J.

    2007-01-01

    This thesis is concerned with the design and construction of an experimental setup aiming to perform ultrahigh-precision g-factor measurements on a bound electron in highly-charged ions. The g-factor of a particle is a dimensionless constant which determines the strength of its interaction with a magnetic field. In the case of an electron bound to a highly-charged ion, it serves as one of the most stringent tests of bound-state quantum electrodynamics (BS-QED). The measurement is based on a triple-Penning-trap system and the continuous Stern-Gerlach effect. The first part of the thesis is devoted to the current knowledge on magnetic moments and motivates the techniques and experimental setup used during the work described. As a major challenge to overcome, the charge breeding of the ions is dealt with in detail, along with the solution found, based on a field-emission-point array. The tools included allow for the measurement of ionization cross-sections by electron impact. The last part of the thesis is dedicated to the design and operation of the triple-Penning-trap setup and the detection schemes implemented. At present, all the experimental setup for the production of highly-charged ions and the corresponding g-factor measurement is completely finalized, including the control system needed for the first measurement stages, so the ion-creation and charge-breeding processes will be the next steps to be taken. (orig.)

  2. Recreating Riser Slugging Flow Based on an Economic Lab-sized Setup

    DEFF Research Database (Denmark)

    Hansen, Lasse; Pedersen, Simon; Yang, Zhenyu

    2013-01-01

    As a kind of periodic phenomenon, the slugging flow in the offshore oil & gas production addresses a lot of attentions, due to its limitation of production rate, periodic overload processing facilities, and even direct cause of emergent shutdown. This work studies the emulation of the riser...... slugging flow in the offshore oil & gas production, by constructing an economical lab-sized setup in the university campus. Firstly, the construction and used components for the lab setup are illustrated; then, the constructed setup is validated by checking the consistency with some existing typical riser...

  3. The ATLAS Level-1 Trigger Timing Setup

    CERN Document Server

    Spiwoks, R; Ellis, Nick; Farthouat, P; Gällnö, P; Haller, J; Krasznahorkay, A; Maeno, T; Pauly, T; Pessoa-Lima, H; Resurreccion-Arcas, I; Schuler, G; De Seixas, J M; Torga-Teixeira, R; Wengler, T

    2005-01-01

    The ATLAS detector at CERN's LHC will be exposed to proton-proton collisions at a bunch-crossing rate of 40 MHz. In order to reduce the data rate, a three-level trigger system selects potentially interesting physics. The first trigger level is implemented in electronics and firmware. It aims at reducing the output rate to less than 100 kHz. The Central Trigger Processor combines information from the calorimeter and muon trigger processors and makes the final Level-1-Accept decision. It is a central element in the timing setup of the experiment. Three aspects are considered in this article: the timing setup with respect to the Level-1 trigger, with respect to the expriment, and with respect to the world.

  4. Physical, Digital, and Hybrid Setups Supporting Card-Based Collaborative Design Ideation

    DEFF Research Database (Denmark)

    Lundqvist, Caroline Emilie; Klinkhammer, Daniel; Dalsgaard, Peter

    2018-01-01

    to supporting collaborative ideation? To answer this question, we present a study and analysis of three different implementations of a well-established collaborative ideation technique called Inspiration Card Workshop, with physical, digital, and hybrid setups. Each setup is evaluated in a controlled experiment...

  5. Radiotherapy for breast cancer: respiratory and set-up uncertainties

    International Nuclear Information System (INIS)

    Saliou, M.G.; Giraud, P.; Simon, L.; Fournier-Bidoz, N.; Fourquet, A.; Dendale, R.; Rosenwald, J.C.; Cosset, J.M.

    2005-01-01

    Adjuvant Radiotherapy has been shown to significantly reduce locoregional recurrence but this advantage is associated with increased cardiovascular and pulmonary morbidities. All uncertainties inherent to conformal radiation therapy must be identified in order to increase the precision of treatment; misestimation of these uncertainties increases the potential risk of geometrical misses with, as a consequence, under-dosage of the tumor and/or overdosage of healthy tissues. Geometric uncertainties due to respiratory movements or set-up errors are well known. Two strategies have been proposed to limit their effect: quantification of these uncertainties, which are then taken into account in the final calculation of safety margins and/or reduction of respiratory and set-up uncertainties by an efficient immobilization or gating systems. Measured on portal films with two tangential fields. CLD (central lung distance), defined as the distance between the deep field edge and the interior chest wall at the central axis, seems to be the best predictor of set-up uncertainties. Using CLD, estimated mean set-up errors from the literature are 3.8 and 3.2 mm for the systematic and random errors respectively. These depend partly on the type of immobilization device and could be reduced by the use of portal imaging systems. Furthermore, breast is mobile during respiration with motion amplitude as high as 0.8 to 10 mm in the anteroposterior direction. Respiratory gating techniques, currently on evaluation, have the potential to reduce effect of these movements. Each radiotherapy department should perform its own assessments and determine the geometric uncertainties with respect of the equipment used and its particular treatment practices. This paper is a review of the main geometric uncertainties in breast treatment, due to respiration and set-up, and solutions proposed to limit their impact. (author)

  6. Slaw extracted proton beam formation and monitoring for the ''QUARTZ'' setup

    International Nuclear Information System (INIS)

    Bushnin, Yu.B.; Gres', V.N.; Davydenko, Yu.P.

    1982-01-01

    The version of optical mode of the beam channel providing with simultaneous operating the experimental setups FODS and ''QUARTZ'' at consecutive usage of the slow extracted proton beam is reported. The ''QUARTZ'' setup beam diagnostics system comprises two subsystems: for measuring beam profile beam timing structure and beam intensity and operates in the beam extraction duration from 20 ns to few seconds at beam intensity from 10 10 to 5x10 12 protons/pulse. The ''QUARTZ'' setup represents a focusing crystal-diffraction spectrometer with 5-meter focal distance and Ge(Li) special construction detector. High efficiency target is applied in the setup. The ''QUARTZ'' setup is designed for studying exotic atoms produced by negative charged heavy particles (π, K, μ, P tilde) and atomic nuclei. Precise energy measurement of X ray transitions in such atoms is performed. For measuring beam geometric parameters 32-channel secondary emission chambers are used. As detector of beam intensity and timing structure of slow extracted beam the secondary emission chamber is employed. The principle circuit of current integrator is given. As data transmission line a 50-pair telephone cable is used. Information conversion into digital form and its subsequent processing is performed in the CAMAC system and the SM-3 computer. The proton beam full intensity measuring system provides with accuracy not worse than +-4.5% in the 10 10 -10 12 proton/sec range. The implemented optical mode of the beam channel and proton beam monitoring system permitted to begin fulfillment of the experimental program on the ''QUARTZ'' setup

  7. Measurement setup at light source operational: Milestone M4.3

    CERN Document Server

    Perez, Francis

    2016-01-01

    The design of the experimental setup for the measurements of the FCC-hh beam screen prototype to be installed at the ANKA lightsource has been completed and the alignment strategy and procedure has been validated by the CERN and KIT teams. In this report, a complete description of the setup and the program of measurements under different operation conditions is presented.

  8. Neutron moderation in a bulk sample and its effects on PGNAA setup geometry

    International Nuclear Information System (INIS)

    Al-Jarallah, M.I.; Naqvi, A.A.; Fazal-ur-Rehman,; Maselehuddin, M.; Abu-Jarad, F.; Raashid, M.

    2003-01-01

    In a prompt gamma ray neutron activation analysis (PGNAA) setup, the neutron moderation in the bulk sample also plays a key role. This can even dominate the thermalization effects of the external moderator in some cases. In order to study the neutron moderation effect in the bulk sample, moderators with two different sizes of the sample were tested at the King Fahd University of Petroleum and Minerals (KFUPM) PGNAA facility. In these tests, the thermal neutron relative intensity and prompt gamma ray yield from the two moderators were measured using nuclear track detectors (NTDs) and NaI detector, respectively. As predicted by Monte Carlo simulations, the measured intensity of thermal neutron inside the large sample cavity due to the external moderator was smaller than that from the smaller sample cavity. Due to its larger size, additional thermalization of neutrons will take place in the larger sample. In spite of smaller thermal neutron yield from the external moderator at the large sample location, higher yield of the prompt gamma ray was observed as compared to that from the smaller sample. This confirms the significance of neutron moderation effects in the bulk sample and can thereby affect the PGNAA geometry size. This allows larger samples in conjunction with smaller moderators in the PGNAA setup

  9. Neutron moderation in a bulk sample and its effects on PGNAA setup geometry

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jarallah, M.I. E-mail: mibrahim@kfupm.edu.sa; Naqvi, A.A.; Fazal-ur-Rehman,; Maselehuddin, M.; Abu-Jarad, F.; Raashid, M

    2003-06-01

    In a prompt gamma ray neutron activation analysis (PGNAA) setup, the neutron moderation in the bulk sample also plays a key role. This can even dominate the thermalization effects of the external moderator in some cases. In order to study the neutron moderation effect in the bulk sample, moderators with two different sizes of the sample were tested at the King Fahd University of Petroleum and Minerals (KFUPM) PGNAA facility. In these tests, the thermal neutron relative intensity and prompt gamma ray yield from the two moderators were measured using nuclear track detectors (NTDs) and NaI detector, respectively. As predicted by Monte Carlo simulations, the measured intensity of thermal neutron inside the large sample cavity due to the external moderator was smaller than that from the smaller sample cavity. Due to its larger size, additional thermalization of neutrons will take place in the larger sample. In spite of smaller thermal neutron yield from the external moderator at the large sample location, higher yield of the prompt gamma ray was observed as compared to that from the smaller sample. This confirms the significance of neutron moderation effects in the bulk sample and can thereby affect the PGNAA geometry size. This allows larger samples in conjunction with smaller moderators in the PGNAA setup.

  10. Pragmatic setup for bioparticle responses by dielectrophoresis for resource limited environment application

    Science.gov (United States)

    Ali, Mohd Anuar Md; Yeop Majlis, Burhanuddin; Kayani, Aminuddin Ahmad

    2017-12-01

    Various dielectrophoretic responses of bioparticles, including cell-chain, spinning, rotation and clustering, are of high interest in the field due to their benefit into application for biomedical and clinical implementation potential. Numerous attempts using sophisticated equipment setup have been studied to perform those dielectrophoretic responses, however, for development into resource limited environment application, such as portable, sustainable and environmental friendly diagnostic tools, establishment of pragmatic setup using standard, non-sophisticated and low-cost equipment is of important task. Here we show the advantages in the judicious design optimization of tip microelectrode, also with selection of suspending medium and optimization of electric signal configuration in establishing setup that can promote the aforementioned dielectrophoretic responses within standard equipments, i.e. pragmatic setup.

  11. Experiment Setup for Focused Learning of Advanced Servo Control of DC-motors

    Directory of Open Access Journals (Sweden)

    Dag A. H. Samuelsen

    2012-02-01

    Full Text Available Remote laboratories are normally developed for giving students and others remote access to physical laboratory facilities. In contradiction to this, the main objective of the setup presented in this paper is to create a controlled environment where unwanted side activities like hardware setup, driver problems, troubleshooting faulty components, and struggles with special software for configuring DSP systems, are removed as much as possible, in order for the students to have their full focus on the tasks that is considered relevant for the module: modeling of non-linear systems, synthetisation of controllers, and stability and performance analysis. A secondary objective is to significantly reduce the setup and maintenance cost associated with complex laboratory setups involving DSPs and expensive hardware.

  12. Evaluating the influence of setup uncertainties on treatment planning for focal liver tumors

    International Nuclear Information System (INIS)

    Balter, J.M.; Brock, K.K.; Lam, K.L.; Dawson, L.A.; McShan, D.L.; Ten Haken, R.K.

    2001-01-01

    Purpose: A mechanism has been developed to evaluate the influence of systematic and random setup variations on dose during treatment planning. The information available for studying these factors shifts from population-based models towards patient-specific data as treatment progresses and setup measurements for an individual patient become available. This study evaluates the influence of population as well as patient-specific setup distributions on treatment plans for focal liver tumors. Materials and Methods: 8 patients with focal liver tumors were treated on a protocol that involved online setup measurement and adjustment, as well as ventilatory immobilization. Summary statistics from these treatments yielded individual and population distributions of position at initial setup for each fraction as well as after setup adjustment. A convolution model for evaluation of the influence of random setup variation on calculated dose distributions has been previously described and investigated for application to focal liver radiotherapy by our department. Individual patient doses based on initial setup positions were calculated by applying the measured systematic offset to the initial treatment plan, and then convolving the calculated dose distribution with an anisotropic probability distribution function representing the individual patient's random variations. A separate calculation with no offset and convolution using population averaged random variations was performed. Individual beam apertures were then adjusted to provide plans that ensured proper dose to the clinical target volume (CTV) following convolution with population distributions prior to and following setup adjustment. Results: Input distributions comprised 262 position measurements. Individual patient setup distributions for the course of treatment had systematic offsets ranging from (σ) 1.1 to 4.1 mm (LR), -2.0 to 1.4 mm (AP), and 5.6 to 1.7 mm (IS). Individual random setup variations ranged from 2.5 to 5

  13. Investigation of applicability of extrapolation method for sample field determination in single-yoke measuring setup

    Czech Academy of Sciences Publication Activity Database

    Stupakov, Oleksandr

    2006-01-01

    Roč. 307, - (2006), s. 279-287 ISSN 0304-8853 R&D Projects: GA AV ČR(CZ) 1QS100100508 Institutional research plan: CEZ:AV0Z10100520 Keywords : magnetic measurement * open magnetic sample * surface field determination * single-yoke setup * magnetic non-destructive testing Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.212, year: 2006

  14. An optimised set-up for total reflection particle induced X-ray emission

    International Nuclear Information System (INIS)

    Kan, J.A. van; Vis, R.D.

    1997-01-01

    MeV proton beams at small angles of incidence (0-35 mrad) are used to analyse trace elements on flat surfaces such as Si wafers or quartz substrates. In these experiments, the particle induced X-ray emission (PIXE) signal is used in a new optimized set-up. This set-up is constructed in such a way that the X-ray detector can reach very large solid angles, larger than 1 sr. Use of these large detector solid angles, combined with the reduction of bremsstrahlung background, affords limits of detection (LOD) of the order of 10 10 at cm -2 using total reflection particle induced X-ray emission (TPIXE). The LODs from earlier TPIXE measurements in a non-optimized set-up are used to estimate LODs in the new TPIXE set-up. Si wafers with low surface concentrations of V, Ni, Cu and Ag are used as standards to calibrate the LODs found with this set-up. The metal concentrations are determined by total reflection X-ray fluorescence (TXRF). The TPIXE measurements are compared with TXRF measurements on the same wafers. (Author)

  15. Eye-in-Hand Manipulation for Remote Handling: Experimental Setup

    Science.gov (United States)

    Niu, Longchuan; Suominen, Olli; Aref, Mohammad M.; Mattila, Jouni; Ruiz, Emilio; Esque, Salvador

    2018-03-01

    A prototype for eye-in-hand manipulation in the context of remote handling in the International Thermonuclear Experimental Reactor (ITER)1 is presented in this paper. The setup consists of an industrial robot manipulator with a modified open control architecture and equipped with a pair of stereoscopic cameras, a force/torque sensor, and pneumatic tools. It is controlled through a haptic device in a mock-up environment. The industrial robot controller has been replaced by a single industrial PC running Xenomai that has a real-time connection to both the robot controller and another Linux PC running as the controller for the haptic device. The new remote handling control environment enables further development of advanced control schemes for autonomous and semi-autonomous manipulation tasks. This setup benefits from a stereovision system for accurate tracking of the target objects with irregular shapes. The overall environmental setup successfully demonstrates the required robustness and precision that remote handling tasks need.

  16. Analysis of Prostate Patient Setup and Tracking Data: Potential Intervention Strategies

    International Nuclear Information System (INIS)

    Su Zhong; Zhang Lisha; Murphy, Martin; Williamson, Jeffrey

    2011-01-01

    Purpose: To evaluate the setup, interfraction, and intrafraction organ motion error distributions and simulate intrafraction intervention strategies for prostate radiotherapy. Methods and Materials: A total of 17 patients underwent treatment setup and were monitored using the Calypso system during radiotherapy. On average, the prostate tracking measurements were performed for 8 min/fraction for 28 fractions for each patient. For both patient couch shift data and intrafraction organ motion data, the systematic and random errors were obtained from the patient population. The planning target volume margins were calculated using the van Herk formula. Two intervention strategies were simulated using the tracking data: the deviation threshold and period. The related planning target volume margins, time costs, and prostate position 'fluctuation' were presented. Results: The required treatment margin for the left-right, superoinferior, and anteroposterior axes was 8.4, 10.8, and 14.7 mm for skin mark-only setup and 1.3, 2.3, and 2.8 mm using the on-line setup correction, respectively. Prostate motion significantly correlated among the superoinferior and anteroposterior directions. Of the 17 patients, 14 had prostate motion within 5 mm of the initial setup position for ≥91.6% of the total tracking time. The treatment margin decreased to 1.1, 1.8, and 2.3 mm with a 3-mm threshold correction and to 0.5, 1.0, and 1.5 mm with an every-2-min correction in the left-right, superoinferior, and anteroposterior directions, respectively. The periodic corrections significantly increase the treatment time and increased the number of instances when the setup correction was made during transient excursions. Conclusions: The residual systematic and random error due to intrafraction prostate motion is small after on-line setup correction. Threshold-based and time-based intervention strategies both reduced the planning target volume margins. The time-based strategies increased the

  17. Setup verification in stereotactic radiotherapy using digitally reconstructed radiograph (DRR)

    International Nuclear Information System (INIS)

    Cho, Byung Chul; Oh, Do Hoon; Bae, Hoon Sik

    1999-01-01

    To develop a method for verifying a treatment setup in stereotactic radiotherapy by matching portal images to DRRs. Four pairs of orthogonal portal images of one patient immobilized by a thermoplastic mast frame for fractionated stereotactic radiotherapy were compared with DRRs. Portal images are obtained in AP (anterior/posterior) and lateral directions with a target localizer box containing fiducial markers attached to a stereotactic frame. DRRs superimposed over a planned isocenter and fiducial markers are printed out on transparent films. And then, they were overlaid over orthogonal portal images by matching anatomical structures. From three different kind of objects (isocenter, fiducial markers, anatomical structure) on DRRs and portal images, the displacement error between anatomical structure and isocenters (overall setup error), and the displacement error between fiducial markers and isocenters (localization error)were measured. Localization errors were 1.5±0.3 mm (lateral), and immobilization errors were 1.9±0.5 mm (AP), 1.9±0.4 mm (lateral). In addition, overall setup errors were 1.6±0.9 mm (AP), 1.3±0.4 mm(lateral). From these orthogonal displacement errors, maximum 3D displacement errors(√(ΔAP) 2 +(ΔLat) 2 ) were found to be 1.7±0.4 mm for localization, 2.6±0.6 mm for immobilization, and 2.3±0.7 mm for overall treatment setup. By comparing orthogonal portal images with DRRs, we find out that it is possible to verify treatment setup directly in stereotactic radiotherapy

  18. A Unique TAS Setup for high multiplicity events at VECC, Kolkata using BaF2 detectors

    Directory of Open Access Journals (Sweden)

    Mukherjee G.

    2014-03-01

    Full Text Available A granular total absorption spectrometer (TAS has been developed at the Variable Energy Cyclotron Centre, Kolkata, India using 50 elements of BaF2 detectors and covering 4π. The advantage with such a granular setup is that one can get sum spectrum with the condition of different multiplicity hits in an event. It has been shown that one can get clean sum-peaks devoid of individual peaks with the choice of two or higher fold of multiplicity. The large granularity makes it a unique TAS setup particularly for the high multiplicity events. The set up has been tested using different radioactive sources with one, two or multiple γ rays in cascade. The set up is ready to be used online.

  19. High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging

    International Nuclear Information System (INIS)

    Bel, Arjan; Vos, Pieter H.; Rodrigus, Patrick T. R.; Creutzberg, Carien L.; Visser, Andries G.; Stroom, Joep C.; Lebesque, Joos V.

    1996-01-01

    Purpose: To investigate in three institutions, The Netherlands Cancer Institute (Antoni van Leeuwenhoek Huis [AvL]), Dr. Daniel den Hoed Cancer Center (DDHC), and Dr, Bernard Verbeeten Institute (BVI), how much the patient setup accuracy for irradiation of prostate cancer can be improved by an offline setup verification and correction procedure, using portal imaging. Methods and Materials: The verification procedure consisted of two stages. During the first stage, setup deviations were measured during a number (N max ) of consecutive initial treatment sessions. The length of the average three dimensional (3D) setup deviation vector was compared with an action level for corrections, which shrunk with the number of setup measurements. After a correction was applied, N max measurements had to be performed again. Each institution chose different values for the initial action level (6, 9, and 10 mm) and N max (2 and 4). The choice of these parameters was based on a simulation of the procedure, using as input preestimated values of random and systematic deviations in each institution. During the second stage of the procedure, with weekly setup measurements, the AvL used a different criterion ('outlier detection') for corrective actions than the DDHC and the BVI ('sliding average'). After each correction the first stage of the procedure was restarted. The procedure was tested for 151 patients (62 in AvL, 47 in DDHC, and 42 in BVI) treated for prostate carcinoma. Treatment techniques and portal image acquisition and analysis were different in each institution. Results: The actual distributions of random and systematic deviations without corrections were estimated by eliminating the effect of the corrections. The percentage of mean (systematic) 3D deviations larger than 5 mm was 26% for the AvL and the DDHC, and 36% for the BVI. The setup accuracy after application of the procedure was considerably improved (percentage of mean 3D deviations larger than 5 mm was 1.6% in the

  20. ATLAS TileCal Sub-Module Production at UIUC - Photos of Prototype PMT Test Setup

    CERN Multimedia

    Errede, Steve

    2001-01-01

    Photo 1 - Entrance to the lab. Photo 2 - A shot of the center of the lab. Photo 3 - The back of the lab. The Dark Box: Photo 4 - A view of the outside of the Dark Box along with its dry nitrogen system. Photo 5 - A view of the inside of the Dark Box. Photo 6 - The LED holder, beam splitter (removed in this shot), and a pulsing circuit. Photo 7 - The PMT holder. Photo 8 - A possible design for a Stepper Motor controlled filter wheel. Photo 9 - Polishing area for the optical fibers. R&D Work on Stepper Motor/Motion Control: Photo 10 - The complete prototype of the Stepper Motor setup. Photo 11 - The prototype of the Main Stepper Motor Driver Board. Photo 12 - The prototype of the Stepper Motor Power Amplifer. Photo 13 - The prototype of the Stepper Motor LabPC + Interface Board.

  1. The set-up for forward scattered particle detection at the external microbeam facility of the INFN-LABEC laboratory in Florence

    International Nuclear Information System (INIS)

    Giuntini, L.; Massi, M.; Calusi, S.; Gelli, N.; Castelli, L.; Carraresi, L.; Czelusniak, C.; Fedi, M.E.; Gueli, A.M.; Liccioli, L.; Mandò, P.A.; Mazzinghi, A.; Palla, L.

    2015-01-01

    In the last few years some new implementations and upgrades have been made to the external scanning microbeam of INFN-LABEC laboratory in Florence, enriching the existing PIXE, PIGE, BS, IBIL set-up with complementary techniques, when possible allowing for simultaneous multi-technique analyses. We developed a system, compatible with the existing set-up, for the out-of-vacuum detection of the forward scattered particles. This system makes feasible the external-STIM (Scanning Transmission Ion Microscopy) and external-FS (Forward Scattering), now both available at our beamline. Test measurements are shortly presented

  2. Measurements of operator performance - an experimental setup

    International Nuclear Information System (INIS)

    Netland, K.

    1980-01-01

    The human has to be considered as an important element in a process control system, even if the degree of automation is extremely high. Other elements, e.g. computer, displays, etc., can to a large extent be described and quantified. The human (operator), is difficult to describe in a precise way, and it is just as difficult to predict his thinking and acting in a control room environment. Many factors influence his performance, such as: experience, motivation, level of knowledge, training, control environment, job organization, etc. These factors have to a certain degree to be described before guidelines for design of the man-process interfaces and the control room layout can be developed. For decades, the psychological science has obtained knowledge of the human mind and behaviour. This knowledge should have the potential of a positive input on our effort to describe the factors influencing the operator performance. Even if the human is complex, a better understanding of his thinking and acting, and a more precise description of the factors influencing his performance can be obtained. At OECD Halden Reactor Project an experimental set-up for such studies has been developed and implemented in the computer laboratory. The present set-up includes elements as a computer- and display-based control room, a simulator representing a nuclear power plant, training programme for the subjects, and methods for the experiments. Set-up modules allow reconfiguration of experiments. (orig./HP)

  3. A Modernized UDM-600 Dynamometer-Based Setup for the Cutting Force Measurement

    Directory of Open Access Journals (Sweden)

    Ya. I. Shuliak

    2016-01-01

    Full Text Available The article considers development of a modernized UDM-600 dynamometer-based setup for measuring the cutting force components. Modernization of existing equipment to improve the method of recording the cutting force components in the automated mode is of relevance. The measuring setup allows recording the cutting force components in turning and milling, as well as the axial force and the torque in the drilling and milling operations.The article presents a block diagram and a schematic diagram of the setup to measure the cutting force components, and describes a basic principle of measuring units within the modernized setup. The developed setup uses a half-bridge strain gauge measuring circuit to record the cutting forces. To enhance the measuring circuit output voltage is used a 16-channel amplifier of LA-UN16 model with a discretely adjustable gain. To record and process electrical signals is used a data acquisition device of NI USB-6009 model, which enables transmitting the received data to a PC via USB-interface. The data acquisition device has a built-in stabilized DC power supply that is used to power the strain gauge bridges. A developed schematic diagram of the measuring setup allows us to realize this measuring device and implement its modernization.Final processing of recorded data is provided through the software developed in visual programming environment LabVIEW 9.0. The program allows us to show the real-time measuring values of the cutting force components graphically and to record the taken data to a text file.The measuring setup modernization enabled increasing measurement accuracy and reducing time for processing and analysis of experimental data obtained when measuring the cutting force components. The MT2 Department of BMSTU uses it in education and research activities and in experimental efforts and laboratory classes.

  4. Quantitative co-localization and pattern analysis of endo-lysosomal cargo in subcellular image cytometry and validation on synthetic image sets

    DEFF Research Database (Denmark)

    Lund, Frederik W.; Wüstner, Daniel

    2017-01-01

    /LYSs. Analysis of endocytic trafficking relies heavily on quantitative fluorescence microscopy, but evaluation of the huge image data sets is challenging and demands computer-assisted statistical tools. Here, we describe how to use SpatTrack (www.sdu.dk/bmb/spattrack), an imaging toolbox, which we developed...... such synthetic vesicle patterns as “ground truth” for validation of two-channel analysis tools in SpatTrack, revealing their high reliability. An improved version of SpatTrack for microscopy-based quantification of cargo transport through the endo-lysosomal system accompanies this protocol....

  5. Production Planning of a Failure-Prone Manufacturing System under Different Setup Scenarios

    Directory of Open Access Journals (Sweden)

    Guy-Richard Kibouka

    2016-01-01

    Full Text Available This paper presents a control problem for the optimization of the production and setup activities of an industrial system operating in an uncertain environment. This system is subject to random disturbances (breakdowns and repairs. These disturbances can engender stock shortages. The considered industrial system represents a well-known production context in industry and consists of a machine producing two types of products. In order to switch production from one product type to another, a time factor and a reconfiguration cost for the machine are associated with the setup activities. The parts production rates and the setup strategies are the decision variables which influence the inventory and the capacity of the system. The objective of the study is to find the production and setup policies which minimize the setup and inventory costs, as well as those associated with shortages. A modeling approach based on stochastic optimal control theory and a numerical algorithm used to solve the obtained optimality conditions are presented. The contribution of the paper, for industrial systems not studied in the literature, is illustrated through a numerical example and a comparative study.

  6. Scintillation forward spectrometer of the SPHERE setup

    International Nuclear Information System (INIS)

    Anisimov, Yu.S.; Afanas'ev, S.V.; Bondarev, V.K.

    1991-01-01

    The construction of the forward spectrometer for the 4π SPHERE setup to study multiple production of particles in nucleus-nucleus interactions is described. The measured parameters of the spectrometer detectors are presented. 7 refs.; 14 figs.; 1 tab

  7. A new instrumental set-up for polarized neutron scattering experiments

    International Nuclear Information System (INIS)

    Schmidt, Wolfgang; Ohl, Michael

    2005-01-01

    Neutron scattering with polarization analysis is a powerful tool to determine magnetic structures and excitations. A common setup is to mount the sample at the center of a Helmholtz-type coil which can provide a magnetic field of any direction at the sample position and also a guide field along the neutron flight paths around the sample. Recent experiments showed quite a high demand for measurements at low momentum transfers. For the corresponding low scattering angles air scattering gives rise to a very large background. For this reason we have extended the standard setup to a combination of a large vacuum tank surrounded by electrical coils. The vacuum tank eliminates the air scattering and we can use the polarization analysis down to the lowest accessible momentum transfers. The coils themselves also show some new features: In contrary to the classic (symmetric) coil distribution we use an asymmetric setup which gives the advantage of a larger scattering window. Due to a more sophisticated current distribution this modified coil arrangement needs not to be rotated for different scattering conditions. The whole set-up will soon be available at IN12, a cold neutrons three-axis spectrometer operated by FZ Juelich in collaboration with CEA Grenoble as a CRG-B instrument at the Institut Laue Langevin in Grenoble

  8. Development and implementation of a nanotomography setup at the PETRA III beamline P05

    International Nuclear Information System (INIS)

    Ogurreck, Malte

    2014-01-01

    X-ray nanotomography is used to analyze materials on the sub-micrometer scale. Many soft biological materials, i.e. most organic tissues, can be imaged with soft X-rays. For materials with a higher electron density, such as bone or teeth, metals, and ceramics, X-ray energies of more than 10 keV need to be used. All these setups require X-ray optics for either direct imaging of the object in question or for preparing a magnified projection. The P05 Imaging Beamline for X-ray micro- and nanotomography is situated at the newly refurbished PETRA III 3 rd generation storage ring at DESY. A dedicated experiment for X-ray nanotomography at higher energies was built in one of the two experimental hutches. An X-ray optics concept tailored for this experiment was specified and an accompanying mechanics concept was devised. Based on these concepts, the experiment was designed and installed. In addition to testing the nanotomography experimental components, the beamline front end was commissioned and the influence of these components on the nanotomography experiment was investigated. Higher harmonics from the undulator and monochromator as well as beam position drifts caused by mechanical drifting the monochromator were investigated to analyze their influence on the nanotomography. The X-ray optics were tested in detail and an operational setup was achieved for both the X-ray microscopy and the cone-beam setup. The achieved resolution of the hard X-ray microscope is better than 100 nm line and space. Nanotomographies were performed on a nanoporous gold sample and a photonic glass sample. Image correlation and correction allowed to perform a reconstruction of the photonic glass sample using a filtered backprojection algorithm. The packing fraction η of the photonic glass could be successfully extracted from the 3D-dataset.

  9. Development and implementation of a nanotomography setup at the PETRA III beamline P05

    Energy Technology Data Exchange (ETDEWEB)

    Ogurreck, Malte

    2014-12-11

    X-ray nanotomography is used to analyze materials on the sub-micrometer scale. Many soft biological materials, i.e. most organic tissues, can be imaged with soft X-rays. For materials with a higher electron density, such as bone or teeth, metals, and ceramics, X-ray energies of more than 10 keV need to be used. All these setups require X-ray optics for either direct imaging of the object in question or for preparing a magnified projection. The P05 Imaging Beamline for X-ray micro- and nanotomography is situated at the newly refurbished PETRA III 3{sup rd} generation storage ring at DESY. A dedicated experiment for X-ray nanotomography at higher energies was built in one of the two experimental hutches. An X-ray optics concept tailored for this experiment was specified and an accompanying mechanics concept was devised. Based on these concepts, the experiment was designed and installed. In addition to testing the nanotomography experimental components, the beamline front end was commissioned and the influence of these components on the nanotomography experiment was investigated. Higher harmonics from the undulator and monochromator as well as beam position drifts caused by mechanical drifting the monochromator were investigated to analyze their influence on the nanotomography. The X-ray optics were tested in detail and an operational setup was achieved for both the X-ray microscopy and the cone-beam setup. The achieved resolution of the hard X-ray microscope is better than 100 nm line and space. Nanotomographies were performed on a nanoporous gold sample and a photonic glass sample. Image correlation and correction allowed to perform a reconstruction of the photonic glass sample using a filtered backprojection algorithm. The packing fraction η of the photonic glass could be successfully extracted from the 3D-dataset.

  10. Fast and thermal neutron intensity measurements at the KFUPM PGNAA setup

    CERN Document Server

    Al-Jarallah, M I; Fazal-Ur-Rehman; Abu-Jarad, F A

    2002-01-01

    Fast and thermal neutron intensity distributions have been measured at an accelerator based prompt gamma ray neutron activation analysis (PGNAA) setup. The setup is built at the 350 keV accelerator laboratory of King Fahd University of Petroleum and Minerals (KFUPM). The setup is mainly designed to carry out PGNAA elemental analysis via thermal neutron capture. In this study relative intensity of fast and thermal neutrons was measured as a function of the PGNAA moderator assembly parameters using nuclear track detectors (NTDs). The relative intensity of the neutrons was measured inside the sample region as a function of front moderator thickness as well as sample length. Measurements were carried out at the KFUPM 350 keV accelerator using 2.8 MeV pulsed neutron beam from D(d,n) reaction. The pulsed deuteron beam with 5 ns pulse width and 30 kHz frequency was used to produce neutrons. Experimental results were compared with results of Monte Carlo design calculations of the PGNAA setup. A good agreement has bee...

  11. Fast and thermal neutron intensity measurements at the KFUPM PGNAA setup

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jarallah, M.I.; Naqvi, A.A. E-mail: aanaqvi@kfupm.edu.sa; Fazal-ur-Rehman; Abu-jarad, F

    2002-10-01

    Fast and thermal neutron intensity distributions have been measured at an accelerator based prompt gamma ray neutron activation analysis (PGNAA) setup. The setup is built at the 350 keV accelerator laboratory of King Fahd University of Petroleum and Minerals (KFUPM). The setup is mainly designed to carry out PGNAA elemental analysis via thermal neutron capture. In this study relative intensity of fast and thermal neutrons was measured as a function of the PGNAA moderator assembly parameters using nuclear track detectors (NTDs). The relative intensity of the neutrons was measured inside the sample region as a function of front moderator thickness as well as sample length. Measurements were carried out at the KFUPM 350 keV accelerator using 2.8 MeV pulsed neutron beam from D(d,n) reaction. The pulsed deuteron beam with 5 ns pulse width and 30 kHz frequency was used to produce neutrons. Experimental results were compared with results of Monte Carlo design calculations of the PGNAA setup. A good agreement has been found between the experimental results and the calculations.

  12. Lower limb immobilization device induced small setup errors in the radiotherapy.

    Science.gov (United States)

    Lu, Yuting; Ni, Xinye; Yu, Jingping; Ni, Xinchu; Sun, Zhiqiang; Wang, Jianlin; Sun, Suping; Wang, Jian

    2018-04-01

    The aim of this study was to design a lower limb immobilization device and investigate its clinical application in the radiotherapy of the lower limbs.Around 38 patients who underwent lower limb radiotherapy using the designed immobilization device were included in this study. The setup errors were calculated by comparison of the portal images and the simulator films or digital reconstructed radiographs (DRRs).From all 38 patients accomplished the radiotherapy using this device, 178 anteroposterior portal images and 178 lateral portal images were used for the analysis of the positional accuracy. Significant differences were observed in the setup error of the head-foot direction compared with the left-right direction (t = 3.404, P = .002) and the anterior-posterior directions (t = 3.188, P = .003). No statistical differences were identified in the setup error in the left-right direction and anterior-posterior direction (t = 0.497, P = .622).The use of the in-house designed lower limb immobilization device allowed for relatively small setup errors. Furthermore, it showed satisfactory accuracy and repeatability.

  13. The high-efficiency γ-ray spectroscopy setup γ{sup 3} at HIγS

    Energy Technology Data Exchange (ETDEWEB)

    Löher, B., E-mail: b.loeher@gsi.de [ExtreMe Matter Institute EMMI and Research Division, GSI Helmholtzzentrum für Schwerionenforschung, Planckstr. 1, 64291 Darmstadt (Germany); Frankfurt Institute for Advanced Studies FIAS, Ruth-Moufang-Str. 1, 60438 Frankfurt am Main (Germany); Derya, V. [Institut für Kernphysik, Universität zu Köln, Zülpicher Str. 77, D-50937 Köln (Germany); Aumann, T. [Institut für Kernphysik, TU Darmstadt, Schlossgartenstr. 9, 64289 Darmstadt (Germany); GSI Helmholtzzentrum für Schwerionenforschung, Planckstr. 1, 64291 Darmstadt (Germany); Beller, J. [Institut für Kernphysik, TU Darmstadt, Schlossgartenstr. 9, 64289 Darmstadt (Germany); Cooper, N. [WNSL, Yale University, P.O. Box 208120, New Haven, CT 06520-8120 (United States); Duchêne, M. [Institut für Kernphysik, TU Darmstadt, Schlossgartenstr. 9, 64289 Darmstadt (Germany); Endres, J. [Institut für Kernphysik, Universität zu Köln, Zülpicher Str. 77, D-50937 Köln (Germany); Fiori, E.; Isaak, J. [ExtreMe Matter Institute EMMI and Research Division, GSI Helmholtzzentrum für Schwerionenforschung, Planckstr. 1, 64291 Darmstadt (Germany); Frankfurt Institute for Advanced Studies FIAS, Ruth-Moufang-Str. 1, 60438 Frankfurt am Main (Germany); and others

    2013-09-21

    The existing Nuclear Resonance Fluorescence (NRF) setup at the HIγS facility at the Triangle Universities Nuclear Laboratory at Duke University has been extended in order to perform γ–γ coincidence experiments. The new setup combines large volume LaBr{sub 3}:Ce detectors and high resolution HPGe detectors in a very close geometry to offer high efficiency, high energy resolution as well as high count rate capabilities at the same time. The combination of a highly efficient γ-ray spectroscopy setup with the mono-energetic high-intensity photon beam of HIγS provides a worldwide unique experimental facility to investigate the γ-decay pattern of dipole excitations in atomic nuclei. The performance of the new setup has been assessed by studying the nucleus {sup 32}S at 8.125 MeV beam energy. The relative γ-decay branching ratio from the 1{sup +} level at 8125.4 keV to the first excited 2{sup +} state was determined to 15.7(3)%. -- Author-Highlights: • We have extended the existing NRF setup at HIγS at TUNL to combine large LaBr and HPGe detectors. • NRF experiments with the mono-energetic beam in combination with Gamma coincidences are possible. • We describe the changes to the experimental setup and data acquisition as well as data analysis. • The performance of the new setup was assessed by investigating the nucleus 32S. • We present a more precisely measured value for the branching ratio for the 1+→2+ transition.

  14. An evaluation of different setups for simulating lighting characteristics

    Science.gov (United States)

    Salters, Bart; Murdoch, Michael; Sekulovksi, Dragan; Chen, Shih-Han; Seuntiens, Pieter

    2012-03-01

    The advance of technology continuously enables new luminaire designs and concepts. Evaluating such designs has traditionally been done using actual prototypes, in a real environment. The iterations needed to build, verify, and improve luminaire designs incur substantial costs and slow down the design process. A more attractive way is to evaluate designs using simulations, as they can be made cheaper and quicker for a wider variety of prototypes. However, the value of such simulations is determined by how closely they predict the outcome of actual perception experiments. In this paper, we discuss an actual perception experiment including several lighting settings in a normal office environment. The same office environment also has been modeled using different software tools, and photo-realistic renderings have been created of these models. These renderings were subsequently processed using various tonemapping operators in preparation for display. The total imaging chain can be considered a simulation setup, and we have executed several perception experiments on different setups. Our real interest is in finding which imaging chain gives us the best result, or in other words, which of them yields the closest match between virtual and real experiment. To answer this question, first of all an answer has to be found to the question, "which simulation setup matches the real world best?" As there is no unique, widely accepted measure to describe the performance of a certain setup, we consider a number of options and discuss the reasoning behind them along with their advantages and disadvantages.

  15. Preliminary Results on Setup Precision of Prone-Lateral Patient Positioning for Whole Breast Irradiation

    International Nuclear Information System (INIS)

    Veldeman, Liv; Speleers, Bruno; Bakker, Marlies; Jacobs, Filip; Coghe, Marc; De Gersem, Werner; Impens, Aline; Nechelput, Sarah; De Wagter, Carlos

    2010-01-01

    Purpose: The aim of this study was to develop a rapid and reproducible technique for prone positioning and to compare dose-volume indices in prone and supine positions. Methods and Materials: Eighteen patients underwent computed tomography imaging for radiotherapy planning in prone and supine position. Experience was gained in the first eight patients, which lead to modifications of the Horizon prone breast board (Civco Medical Solutions, Orange City, Iowa, USA) and the patient setup technique. A unilateral breast holder (U-BH) was developed (Van de Velde, Schellebelle, Belgium) to retract the contralateral breast away from the treated breast. The technique was then applied to an additional 10 patients. The setup precision was evaluated using daily cone-beam CT. Results: Modifications to the breast board were made to secure a prone-lateral rather then a pure prone position. We evolved from a classical setup using laser marks on the patients' body to a direct breast setup using marks on the breast only. The setup precision of the direct positioning procedure with the modified breast board and the U-BH is comparable to supine setup data in the literature. Dose-volume indices for heart and lung show significantly better results for prone than for supine position, and dose homogeneity within the treated breast did not differ according to the treatment position. Conclusions: The setup precision of our prone-lateral positioning technique is comparable to supine data in literature. Our data show the advantage of prone radiotherapy to spare the lung and heart. Further research is necessary to reduce the duration of prone setup.

  16. Impact of cradle immobilization on setup reproducibility during external beam radiation therapy for lung cancer

    International Nuclear Information System (INIS)

    Bentel, Gunilla C.; Marks, Lawrence B.; Krishnamurthy, Rupa

    1997-01-01

    Purpose: To compare the setup accuracy during fractionated radiation therapy for two patient groups with lung cancer treated with and without an immobilization cradle. Methods: Three hundred ninety-seven port films from 30 patients immobilized in the Alpha Cradle TM1 were compared with 329 port films from 30 patients who were not immobilized with the cradle. All patients were treated with curative intent for nonmetastatic lung cancer. The frequency of physician-requested isocenter shifts were compared in the two groups using a two-tailed chi-square test. Initial port films taken on the first day of treatment, routine films taken usually weekly during radiation therapy, and requested films taken after a requested shift were considered separately. The immobilization device consisted of a custom-made foam cradle that extended from above the head to the knees. Patients were generally treated with their arms above their heads, and treatment setup marks in the immobilized patients were placed on both the patients' skin and the immobilization cradle. For the noncradle patients, setup marks were placed only on the patients' skin. Results: For the routine films, the frequency of physician-requested isocenter shifts was lower in immobilized patients than in the nonimmobilized group (p = 0.139). Most of this reduction was seen on oblique fields (p = 0.038). No benefits were seen among initial or requested films. The two groups were well balanced with regard to stage, age, field size, and total dose. Conclusions: The use of aggressive immobilization improves the setup reproducibility in patients receiving external beam radiation therapy for lung cancer, especially during treatment with oblique fields. This improvement in treatment accuracy might improve the therapeutic ratio

  17. Estimation of functional preparedness of young handballers in setup time

    Directory of Open Access Journals (Sweden)

    Favoritоv V.N.

    2012-11-01

    Full Text Available The dynamics of level of functional preparedness of young handballers in setup time is shown. It was foreseen to make alteration in educational-training process with the purpose of optimization of their functional preparedness. 11 youths were plugged in research, calendar age 14 - 15 years. For determination of level of their functional preparedness the computer program "SVSM" was applied. It is set that at the beginning of setup time of 18,18% of all respondent functional preparedness is characterized by a "middle" level, 27,27% - below the "average", 54,54% - "above" the average. At the end of setup time among sportsmen representatives prevailed with the level of functional preparedness "above" average - 63,63%, with level "high" - 27,27%, sportsmen with level below the average were not observed. Efficiency of the offered system of trainings employments for optimization of functional preparedness of young handballers is well-proven.

  18. On Radiated Performance Evaluation of Massive MIMO Devices in Multi-Probe Anechoic Chamber OTA Setups

    DEFF Research Database (Denmark)

    Kyösti, Pekka; Hentilä, Lassi; Fan, Wei

    2018-01-01

    Radiated testing of massive multiple-input-multipleoutput (MIMO) devices in fading radio channel conditions is expected to be essential in development of the fifth generation (5G) base stations (BS) and user equipment (UE) operating at or close to the millimetre wave (mm-wave) frequencies. In thi...... setup and find key design parameters by simulations. The results with the utilized channel models indicate that at 28 GHz up to 1616 planar arrays can be tested with range length of one meter and with at minimum eight active dual polarized probes....

  19. Reliable experimental setup to test the pressure modulation of Baerveldt Implant tubes for reducing post-operative hypotony

    Science.gov (United States)

    Ramani, Ajay

    Glaucoma encompasses a group of conditions that result in damage to the optic nerve and can cause loss of vision and blindness. The nerve is damaged due to an increase in the eye's internal (intraocular) pressure (IOP) above the nominal range of 15 -- 20 mm Hg. There are many treatments available for this group of diseases depending on the complexity and stage of nerve degradation. In extreme cases where drugs or laser surgery do not create better conditions for the patient, ophthalmologists use glaucoma drainage devices to help alleviate the IOP. Many drainage implants have been developed over the years and are in use; but two popular implants are the Baerveldt Glaucoma Implant and the Ahmed Glaucoma Valve Implant. Baerveldt Implants are non-valved and provide low initial resistance to outflow of fluid, resulting in post-operative complications such as hypotony, where the IOP drops below 5 mm of Hg. Ahmed Glaucoma Valve Implants are valved implants which initially restrict the amount of fluid flowing out of the eye. The long term success rates of Baerveldt Implants surpass those of Ahmed Valve Implants because of post-surgical issues; but Baerveldt Implants' initial effectiveness is poor without proper flow restriction. This drives the need to develop new ways to improve the initial effectiveness of Baerveldt Implants. A possible solution proposed by our research team is to place an insert in the Baerveldt Implant tube of inner diameter 305 microns. The insert must be designed to provide flow resistance for the early time frame [e.g., first 30 -- 60 post-operative days] until sufficient scar tissue has formed on the implant. After that initial stage with the insert, the scar tissue will provide the necessary flow resistance to maintain the IOP above 5 mm Hg. The main objective of this project was to develop and validate an experimental apparatus to measure pressure drop across a Baerveldt Implant tube, with and without inserts. This setup will be used in the

  20. Electric field stimulation setup for photoemission electron microscopes.

    Science.gov (United States)

    Buzzi, M; Vaz, C A F; Raabe, J; Nolting, F

    2015-08-01

    Manipulating magnetisation by the application of an electric field in magnetoelectric multiferroics represents a timely issue due to the potential applications in low power electronics and the novel physics involved. Thanks to its element sensitivity and high spatial resolution, X-ray photoemission electron microscopy is a uniquely suited technique for the investigation of magnetoelectric coupling in multiferroic materials. In this work, we present a setup that allows for the application of in situ electric and magnetic fields while the sample is analysed in the microscope. As an example of the performances of the setup, we present measurements on Ni/Pb(Mg(0.66)Nb(0.33))O3-PbTiO3 and La(0.7)Sr(0.3)MnO3/PMN-PT artificial multiferroic nanostructures.

  1. View of the WA10 set-up

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    The WA10 experiment by the Geneva-Lausanne Collaboration was set-up in the H5 beam (unseparated, up to 50 GeV/c) to study K+-p --> K0pi+-p and other reactions of similar topology, and the energy dependence of resonance production.

  2. Ostreid herpesvirus 1 infection among Pacific oyster (Crassostrea gigas) Spat: relevance of water temperature to virus replication and circulation prior to the onset of mortality.

    Science.gov (United States)

    Renault, Tristan; Bouquet, Anne Lise; Maurice, Julien-Thomas; Lupo, Coralie; Blachier, Philippe

    2014-09-01

    A number of bivalve species worldwide, including the Pacific oyster, Crassostrea gigas, have been affected by mass mortality events associated with herpesviruses, resulting in significant losses. A particular herpesvirus was purified from naturally infected larval Pacific oysters, and its genome was completely sequenced. This virus has been classified as Ostreid herpesvirus 1 (OsHV-1) within the family Malacoherpesviridae. Since 2008, mass mortality outbreaks among C. gigas in Europe have been related to the detection of a variant of OsHV-1 called μVar. Additional data are necessary to better describe mortality events in relation to environmental-parameter fluctuations and OsHV-1 detection. For this purpose, a single batch of Pacific oyster spat was deployed in 4 different locations in the Marennes-Oleron area (France): an oyster pond ("claire"), a shellfish nursery, and two locations in the field. Mortality rates were recorded based on regular observation, and samples were collected to search for and quantify OsHV-1 DNA by real-time PCR. Although similar massive mortality rates were reported at the 4 sites, mortality was detected earlier in the pond and in the nursery than at both field sites. This difference may be related to earlier increases in water temperature. Mass mortality was observed among oysters a few days after increases in the number of PCR-positive oysters and viral-DNA amounts were recorded. An initial increment in the number of PCR-positive oysters was reported at both field sites during the survey in the absence of significant mortality. During this period, the water temperature was below 16°C. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  3. Interfractional Variations in Patient Setup and Anatomic Change Assessed by Daily Computed Tomography

    International Nuclear Information System (INIS)

    Li, X. Allen; Qi, X. Sharon; Pitterle, Marissa; Kalakota, Kapila; Mueller, Kevin; Erickson, Beth A.; Wang Dian; Schultz, Christopher J.; Firat, Selim Y.; Wilson, J. Frank

    2007-01-01

    Purpose: To analyze the interfractional variations in patient setup and anatomic changes at seven anatomic sites observed in image-guided radiotherapy. Methods and Materials: A total of 152 patients treated at seven anatomic sites using a Hi-Art helical tomotherapy system were analyzed. Daily tomotherapy megavoltage computed tomography images acquired before each treatment were fused to the planning kilovoltage computed tomography images to determine the daily setup errors and organ motions and deformations. The setup errors were corrected before treatment and were used, along with the organ motions, to determine the clinical target volume/planning target volume margins. The organ motions and deformations for 3 representative patient cases (pancreas, uterus, and soft-tissue sarcoma) and for 14 kidneys of 7 patients are presented. Results: Interfractional setup errors in the skull, brain, and head and neck are significantly smaller than those in the chest, abdomen, pelvis, and extremities. These site-specific relationships are statistically significant. The margins required to account for these setup errors range from 3 to 8 mm for the seven sites. The margin to account for both setup errors and organ motions for kidney is 16 mm. Substantial interfractional anatomic changes were observed. For example, the pancreas moved up to ±20 mm and volumes of the uterus and sarcoma varied ≤30% and 100%, respectively. Conclusion: The interfractional variations in patient setup and in shapes, sizes, and positions of both targets and normal structures are site specific and may be used to determine the site-specific margins. The data presented in this work dealing with seven anatomic sites may be useful in developing adaptive radiotherapy

  4. Diffuse back-illumination setup for high temporally resolved extinction imaging

    DEFF Research Database (Denmark)

    Westlye, Fredrik Ree; Penney, Keith; Ivarsson, Anders

    2017-01-01

    -steering suppression. Methods for complete characterization of the optical system are detailed. Measurements of the liquid-vapor boundary and the soot volume fraction in an automotive spray are presented to demonstrate the resulting improved contrast and reduced uncertainty. The current optical setup reduces......This work presents the development of an optical setup for quantitative, high-temporal resolution line-of-sight extinction imaging in harsh optical environments. The application specifically targets measurements of automotive fuel sprays at high ambient temperature and pressure conditions where...

  5. Setup Variations in Radiotherapy of Esophageal Cancer: Evaluation by Daily Megavoltage Computed Tomographic Localization

    International Nuclear Information System (INIS)

    Chen, Y.-J.; Han Chunhui; Liu An; Schultheiss, Timothy E.; Kernstine, Kemp H.; Shibata, Stephen; Vora, Nayana L.; Pezner, Richard D.; Wong, Jeffrey Y.C.

    2007-01-01

    Purpose: To use pretreatment megavoltage computed tomography (MVCT) scans to evaluate setup variations in anterior-posterior (AP), lateral, and superior-inferior (SI) directions and rotational variations, including pitch, roll, and yaw, for esophageal cancer patients treated with helical tomotherapy. Methods and Materials: Ten patients with locally advanced esophageal cancer treated by combined chemoradiation using helical tomotherapy were selected. After patients were positioned using their skin tattoos/marks, MVCT scans were performed before every treatment and automatically registered to planning kilovoltage CT scans according to bony landmarks. Image registration data were used to adjust patient setups before treatment. A total of 250 MVCT scans were analyzed. Correlations between setup variations and body habitus, including height, weight, relative weight change, body surface area, and patient age, were evaluated. Results: The standard deviations for systematic setup corrections in AP, lateral, and SI directions and pitch, roll, and yaw rotations were 1.5, 3.7, and 4.8 mm and 0.5 deg., 1.2 deg., and 0.8 deg., respectively. The appropriate averages of random setup variations in AP, lateral, and SI directions and pitch, roll, and yaw rotations were 2.9, 5.2, and 4.4 mm, and 1.0 deg., 1.2 deg., and 1.1 deg., respectively. Setup variations were stable throughout the entire course of radiotherapy in all three translational and three rotational displacements, with little change in magnitude. No significant correlations were found between setup variations and body habitus variables. Conclusions: Daily MVCT scans before each treatment can effectively detect setup errors and thereby reduce planning target volume (PTV) margins. This will reduce radiation dose to critical organs and may translate into lower treatment-related toxicities

  6. Technical Note: Introduction of variance component analysis to setup error analysis in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Matsuo, Yukinori, E-mail: ymatsuo@kuhp.kyoto-u.ac.jp; Nakamura, Mitsuhiro; Mizowaki, Takashi; Hiraoka, Masahiro [Department of Radiation Oncology and Image-applied Therapy, Kyoto University, 54 Shogoin-Kawaharacho, Sakyo, Kyoto 606-8507 (Japan)

    2016-09-15

    Purpose: The purpose of this technical note is to introduce variance component analysis to the estimation of systematic and random components in setup error of radiotherapy. Methods: Balanced data according to the one-factor random effect model were assumed. Results: Analysis-of-variance (ANOVA)-based computation was applied to estimate the values and their confidence intervals (CIs) for systematic and random errors and the population mean of setup errors. The conventional method overestimates systematic error, especially in hypofractionated settings. The CI for systematic error becomes much wider than that for random error. The ANOVA-based estimation can be extended to a multifactor model considering multiple causes of setup errors (e.g., interpatient, interfraction, and intrafraction). Conclusions: Variance component analysis may lead to novel applications to setup error analysis in radiotherapy.

  7. Technical Note: Introduction of variance component analysis to setup error analysis in radiotherapy

    International Nuclear Information System (INIS)

    Matsuo, Yukinori; Nakamura, Mitsuhiro; Mizowaki, Takashi; Hiraoka, Masahiro

    2016-01-01

    Purpose: The purpose of this technical note is to introduce variance component analysis to the estimation of systematic and random components in setup error of radiotherapy. Methods: Balanced data according to the one-factor random effect model were assumed. Results: Analysis-of-variance (ANOVA)-based computation was applied to estimate the values and their confidence intervals (CIs) for systematic and random errors and the population mean of setup errors. The conventional method overestimates systematic error, especially in hypofractionated settings. The CI for systematic error becomes much wider than that for random error. The ANOVA-based estimation can be extended to a multifactor model considering multiple causes of setup errors (e.g., interpatient, interfraction, and intrafraction). Conclusions: Variance component analysis may lead to novel applications to setup error analysis in radiotherapy.

  8. Off-line software for large experimental setups

    International Nuclear Information System (INIS)

    Bruyant, F.

    1983-07-01

    The purpose of this report is to emphasize the importance of Off-line software for large experimental setups in High Energy Physics. Simple notions of program structuring, data structuring and software organization are discussed in the context of the software developped for the European Hybrid Spectrometer. (author)

  9. The value of setup portal films as an estimate of a patient's position throughout fractionated tangential breast irradiation: an on-line study

    International Nuclear Information System (INIS)

    McGee, Kiaran P.; Fein, Douglas A.; Hanlon, Alex L.; Schultheiss, Timothy E.; Fowble, Barbara L.

    1997-01-01

    Purpose: To determine if portal setup films are an accurate representation of a patient's position throughout the course of fractionated tangential breast irradiation. Methods and Materials: Thirteen patients undergoing external beam irradiation for T1-T2 infiltrating ductal carcinoma of the breast following excisional biopsy and axillary dissection were imaged using an on-line portal imaging device attached to a 6 MV linear accelerator. Medial and lateral tangential fields were imaged and a total of 139 fractions, 225 portal fields, and 4450 images were obtained. Interfractional and intrafractional variations for anatomical parameters including the central lung distance (CLD), central flash distance (CFD), and inferior central margin (ICM) were calculated from these images. A pooled estimate of the random error associated with a given treatment was determined by adding the interfractional and intrafractional standard deviations in quadrature. A 95% confidence level assigned a value of two standard deviations of the random error estimate. Central lung distance, CFD, and ICM distances were then measured for all portal setup films. Significant differences were defined as occurring when the simulation-setup difference was greater than the 95% confidence value. Results: Differences between setup portal and simulation films were less than their 95% confidence values in 70 instances indicating that in 90% of the time these differences are a result of random differences in daily treatment positioning. Conclusions: In 90% of cases tested, initial portal setup films are an accurate representation of a patients daily treatment setup

  10. Integrated trimodal SSEP experimental setup for visual, auditory and tactile stimulation

    Science.gov (United States)

    Kuś, Rafał; Spustek, Tomasz; Zieleniewska, Magdalena; Duszyk, Anna; Rogowski, Piotr; Suffczyński, Piotr

    2017-12-01

    Objective. Steady-state evoked potentials (SSEPs), the brain responses to repetitive stimulation, are commonly used in both clinical practice and scientific research. Particular brain mechanisms underlying SSEPs in different modalities (i.e. visual, auditory and tactile) are very complex and still not completely understood. Each response has distinct resonant frequencies and exhibits a particular brain topography. Moreover, the topography can be frequency-dependent, as in case of auditory potentials. However, to study each modality separately and also to investigate multisensory interactions through multimodal experiments, a proper experimental setup appears to be of critical importance. The aim of this study was to design and evaluate a novel SSEP experimental setup providing a repetitive stimulation in three different modalities (visual, tactile and auditory) with a precise control of stimuli parameters. Results from a pilot study with a stimulation in a particular modality and in two modalities simultaneously prove the feasibility of the device to study SSEP phenomenon. Approach. We developed a setup of three separate stimulators that allows for a precise generation of repetitive stimuli. Besides sequential stimulation in a particular modality, parallel stimulation in up to three different modalities can be delivered. Stimulus in each modality is characterized by a stimulation frequency and a waveform (sine or square wave). We also present a novel methodology for the analysis of SSEPs. Main results. Apart from constructing the experimental setup, we conducted a pilot study with both sequential and simultaneous stimulation paradigms. EEG signals recorded during this study were analyzed with advanced methodology based on spatial filtering and adaptive approximation, followed by statistical evaluation. Significance. We developed a novel experimental setup for performing SSEP experiments. In this sense our study continues the ongoing research in this field. On the

  11. Electronic portal image assisted reduction of systematic set-up errors in head and neck irradiation

    International Nuclear Information System (INIS)

    Boer, Hans C.J. de; Soernsen de Koste, John R. van; Creutzberg, Carien L.; Visser, Andries G.; Levendag, Peter C.; Heijmen, Ben J.M.

    2001-01-01

    Purpose: To quantify systematic and random patient set-up errors in head and neck irradiation and to investigate the impact of an off-line correction protocol on the systematic errors. Material and methods: Electronic portal images were obtained for 31 patients treated for primary supra-glottic larynx carcinoma who were immobilised using a polyvinyl chloride cast. The observed patient set-up errors were input to the shrinking action level (SAL) off-line decision protocol and appropriate set-up corrections were applied. To assess the impact of the protocol, the positioning accuracy without application of set-up corrections was reconstructed. Results: The set-up errors obtained without set-up corrections (1 standard deviation (SD)=1.5-2 mm for random and systematic errors) were comparable to those reported in other studies on similar fixation devices. On an average, six fractions per patient were imaged and the set-up of half the patients was changed due to the decision protocol. Most changes were detected during weekly check measurements, not during the first days of treatment. The application of the SAL protocol reduced the width of the distribution of systematic errors to 1 mm (1 SD), as expected from simulations. A retrospective analysis showed that this accuracy should be attainable with only two measurements per patient using a different off-line correction protocol, which does not apply action levels. Conclusions: Off-line verification protocols can be particularly effective in head and neck patients due to the smallness of the random set-up errors. The excellent set-up reproducibility that can be achieved with such protocols enables accurate dose delivery in conformal treatments

  12. Analysis of dispatching rules in a stochastic dynamic job shop manufacturing system with sequence-dependent setup times

    Science.gov (United States)

    Sharma, Pankaj; Jain, Ajai

    2014-12-01

    Stochastic dynamic job shop scheduling problem with consideration of sequence-dependent setup times are among the most difficult classes of scheduling problems. This paper assesses the performance of nine dispatching rules in such shop from makespan, mean flow time, maximum flow time, mean tardiness, maximum tardiness, number of tardy jobs, total setups and mean setup time performance measures viewpoint. A discrete event simulation model of a stochastic dynamic job shop manufacturing system is developed for investigation purpose. Nine dispatching rules identified from literature are incorporated in the simulation model. The simulation experiments are conducted under due date tightness factor of 3, shop utilization percentage of 90% and setup times less than processing times. Results indicate that shortest setup time (SIMSET) rule provides the best performance for mean flow time and number of tardy jobs measures. The job with similar setup and modified earliest due date (JMEDD) rule provides the best performance for makespan, maximum flow time, mean tardiness, maximum tardiness, total setups and mean setup time measures.

  13. Comparison of orthogonal kilovolt X-ray images and cone-beam CT matching results in setup error assessment and correction for EB-PBI during free breathing

    International Nuclear Information System (INIS)

    Wang Wei; Li Jianbin; Hu Hongguang; Ma Zhifang; Xu Min; Fan Tingyong; Shao Qian; Ding Yun

    2014-01-01

    Objective: To compare the differences in setup error (SE) assessment and correction between the orthogonal kilovolt X-ray images and CBCT in EB-PBI patients during free breathing. Methods: Nineteen patients after breast conserving surgery EB-PBI were recruited. Interfraction SE was acquired using orthogonal kilovolt X-ray setup images and CBCT, after on-line setup correction,calculate the residual error and compare the SE, residual error and setup margin (SM) quantified for orthogonal kilovolt X-ray images and CBCT. Wilcoxon sign-rank test was used to evaluate the differences. Results: The CBCT based SE (systematic error, ∑) was smaller than the orthogonal kilovolt X-ray images based ∑ in AP direction (-1.2 mm vs 2.00 mm; P=0.005), and there was no statistically significant differences for three dimensional directions in random error (σ) (P=0.948, 0.376, 0.314). After on-line setup correction,CBCT decreases setup residual error than the orthogonal kilovolt X-ray images in AP direction (Σ: -0.20 mm vs 0.50 mm, P=0.008; σ: 0.45 mm vs 1.34 mm, P=0.002). And also the CBCT based SM was smaller than orthogonal kilovolt X-ray images based SM in AP direction (Σ: -1.39 mm vs 5.57 mm, P=0.003; σ: 0.00 mm vs 3.2 mm, P=0.003). Conclusions: Compared with kilovolt X-ray images, CBCT underestimate the setup error in the AP direction, but decreases setup residual error significantly.An image-guided radiotherapy and setup error assessment using kilovolt X-ray images for EB-PBI plans was feasible. (authors)

  14. FESetup: Automating Setup for Alchemical Free Energy Simulations.

    Science.gov (United States)

    Loeffler, Hannes H; Michel, Julien; Woods, Christopher

    2015-12-28

    FESetup is a new pipeline tool which can be used flexibly within larger workflows. The tool aims to support fast and easy setup of alchemical free energy simulations for molecular simulation packages such as AMBER, GROMACS, Sire, or NAMD. Post-processing methods like MM-PBSA and LIE can be set up as well. Ligands are automatically parametrized with AM1-BCC, and atom mappings for a single topology description are computed with a maximum common substructure search (MCSS) algorithm. An abstract molecular dynamics (MD) engine can be used for equilibration prior to free energy setup or standalone. Currently, all modern AMBER force fields are supported. Ease of use, robustness of the code, and automation where it is feasible are the main development goals. The project follows an open development model, and we welcome contributions.

  15. A Novel Geometry for Shear Test Using Axial Tensile Setup

    Directory of Open Access Journals (Sweden)

    Sibo Yuan

    2018-05-01

    Full Text Available This paper studies a novel geometry for the in-plane shear test performed with an axial electromechanical testing machine. In order to investigate the influence of the triaxiality rate on the mechanical behavior, different tests will be performed on the studied material: simple tensile tests, large tensile tests and shear tests. For the whole campaign, a common equipment should be employed to minimize the impact of the testing device. As a consequence, for the shear tests, the geometry of the specimen must be carefully designed in order to adapt the force value and make it comparable to the one obtained for the tensile tests. Like most of the existing shear-included tensile test specimens, the axial loading is converted to shear loading at a particular region through the effect of geometry. A symmetric shape is generally preferred, since it can restrict the in-plane rotation of the shear section, keep shear increasing in a more monotonic path and double the force level thanks to the two shear zones. Due to the specific experimental conditions, such as dimensions of the furnace and the clamping system, the position of the extensometer or the restriction of sheet thickness (related to the further studies of size effect at mesoscale and hot temperature, several geometries were brought up and evaluated in an iterative procedure via finite element simulations. Both the numerical and experimental results reveal that the final geometry ensures some advantages. For instance, a relatively low triaxiality in the shear zone, limited in-plane rotation and no necking are observed. Moreover, it also prevents any out-of-plane displacement of the specimen which seems to be highly sensitive to the geometry, and presents a very limited influence of the material and the thickness.

  16. Design of an experimental four-camera setup for enhanced 3D surface reconstruction in microsurgery

    Directory of Open Access Journals (Sweden)

    Marzi Christian

    2017-09-01

    Full Text Available Future fully digital surgical visualization systems enable a wide range of new options. Caused by optomechanical limitations a main disadvantage of today’s surgical microscopes is their incapability of providing arbitrary perspectives to more than two observers. In a fully digital microscopic system, multiple arbitrary views can be generated from a 3D reconstruction. Modern surgical microscopes allow replacing the eyepieces by cameras in order to record stereoscopic videos. A reconstruction from these videos can only contain the amount of detail the recording camera system gathers from the scene. Therefore, covered surfaces can result in a faulty reconstruction for deviating stereoscopic perspectives. By adding cameras recording the object from different angles, additional information of the scene is acquired, allowing to improve the reconstruction. Our approach is to use a fixed four-camera setup as a front-end system to capture enhanced 3D topography of a pseudo-surgical scene. This experimental setup would provide images for the reconstruction algorithms and generation of multiple observing stereo perspectives. The concept of the designed setup is based on the common main objective (CMO principle of current surgical microscopes. These systems are well established and optically mature. Furthermore, the CMO principle allows a more compact design and a lowered effort in calibration than cameras with separate optics. Behind the CMO four pupils separate the four channels which are recorded by one camera each. The designed system captures an area of approximately 28mm × 28mm with four cameras. Thus, allowing to process images of 6 different stereo perspectives. In order to verify the setup, it is modelled in silico. It can be used in further studies to test algorithms for 3D reconstruction from up to four perspectives and provide information about the impact of additionally recorded perspectives on the enhancement of a reconstruction.

  17. Setup error in radiotherapy: on-line correction using electronic kilovoltage and megavoltage radiographs

    International Nuclear Information System (INIS)

    Pisani, Laura; Lockman, David; Jaffray, David; Yan Di; Martinez, Alvaro; Wong, John

    2000-01-01

    Purpose: We hypothesize that the difference in image quality between the traditional kilovoltage (kV) prescription radiographs and megavoltage (MV) treatment radiographs is a major factor hindering our ability to accurately measure, thus correct, setup error in radiation therapy. The objective of this work is to study the accuracy of on-line correction of setup errors achievable using either kV- or MV-localization (i.e., open-field) radiographs. Methods and Materials: Using a gantry mounted kV and MV dual-beam imaging system, the accuracy of on-line measurement and correction of setup error using electronic kV- and MV-localization images was examined based on anthropomorphic phantom and patient imaging studies. For the phantom study, the user's ability to accurately detect known translational shifts was analyzed. The clinical study included 14 patients with disease in the head and neck, thoracic, and pelvic regions. For each patient, 4 orthogonal kV radiographs acquired during treatment simulation from the right lateral, anterior-to-posterior, left lateral, and posterior-to-anterior directions were employed as reference prescription images. Two-dimensional (2D) anatomic templates were defined on each of the 4 reference images. On each treatment day, after positioning the patient for treatment, 4 orthogonal electronic localization images were acquired with both kV and 6-MV photon beams. On alternate weeks, setup errors were determined from either the kV- or MV-localization images but not both. Setup error was determined by aligning each 2D template with the anatomic information on the corresponding localization image, ignoring rotational and nonrigid variations. For each set of 4 orthogonal images, the results from template alignments were averaged. Based on the results from the phantom study and a parallel study of the inter- and intraobserver template alignment variability, a threshold for minimum correction was set at 2 mm in any direction. Setup correction was

  18. Poster - 33: Dosimetry Comparison of Prone Breast Forward and Inverse Treatment planning considering daily setup variations

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Runqing; Zhan, Lixin; Osei, Ernest [Grand River Regional Cancer Centre (Canada)

    2016-08-15

    Introduction: The purpose of this study is to investigate the effects of daily setup variations on prone breast forward field-in-field (FinF) and inverse IMRT treatment planning. Methods: Rando Phantom (Left breast) and Pixy phantom (Right breast) were built and CT scanned in prone position. The treatment planning (TP) is performed in Eclipse TP system. Forward FinF plan and inverse IMRT plan were created to satisfy the CTV coverage and OARs criteria. The daily setup variations were assumed to be 5 mm at left-right, superior-inferior, and anterior-posterior directions. The DVHs of CTV coverage and OARs were compared for both forward FinF plan and inverse IMRT plans due to 5mm setup variation. Results and Discussions: DVHs of CTV coverage had fewer variations for 5m setup variation for forward FinF and inverse IMRT plan for both phantoms. However, for the setup variations in the left-right direction, the DVH of CTV coverage of IMRT plan showed the worst variation due to lateral setup variation for both phantoms. For anterior-posterior variation, the CTV could not get full coverage when the breast chest wall is shallow; however, with the guidance of MV imaging, breast chest wall will be checked during the MV imaging setup. So the setup variations have more effects on inverse IMRT plan, compared to forward FinF plan, especially in the left-right direction. Conclusions: The Forward FinF plan was recommended clinically considering daily setup variation.

  19. Effectiveness of couch height-based patient set-up and an off-line correction protocol in prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Lin, Emile N.J.Th. van; Nijenhuis, Edwin; Huizenga, Henk; Vight, Lisette van der; Visser, Andries

    2001-01-01

    Purpose: To investigate set-up improvement caused by applying a couch height-based patient set-up method in combination with a technologist-driven off-line correction protocol in nonimmobilized radiotherapy of prostate patients. Methods and Materials: A three-dimensional shrinking action level correction protocol is applied in two consecutive patient cohorts with different set-up methods: the traditional 'laser set-up' group (n=43) and the 'couch height set-up' group (n=112). For all directions, left-right, ventro-dorsal, and cranio-caudal, random and systematic set-up deviations were measured. Results: The couch height set-up method improves the patient positioning compared to the laser set-up method. Without application of the correction protocol, both systematic and random errors reduced to 2.2-2.4 mm (1 SD) and 1.7-2.2 mm (1 SD), respectively. By using the correction protocol, systematic errors reduced further to 1.3-1.6 mm (1 SD). One-dimensional deviations were within 5 mm for >90% of the measured fractions. The required number of corrections per patient in the off-line correction protocol was reduced significantly during the course of treatment from 1.1 to 0.6 by the couch height set-up method. The treatment time was not prolonged by application of the correction protocol. Conclusions: The couch height set-up method improves the set-up significantly, especially in the ventro-dorsal direction. Combination of this set-up method with an off-line correction strategy, executed by technologists, reduces the number of set-up corrections required

  20. Impact of setup variability on incidental lung irradiation during tangential breast treatment

    International Nuclear Information System (INIS)

    Carter, Dennis L.; Marks, Lawrence B.; Bentel, Gunilla C.

    1997-01-01

    Purpose: This study aimed to determine the variability in treatment setup during a 5-week course of tangential breast treatment for patients immobilized in a customized hemibody cradle, to assess the relationship between the height of the lung shadow on the tangential port film and the percentage of lung volume irradiated, and to estimate the impact of setup variabilities on irradiated lung volume. Methods: One hundred seventy-two port films were reviewed from 20 patients who received tangential beam treatment for breast cancer. The height of the lung shadow at the central axis (CLD) on each port film was compared to the corresponding simulator film as an assessment of setup variability. A three-dimensional dose calculation was performed, and the percentage of total lung volume within the field was correlated with the CLD. The three-dimensional dose calculation was repeated for selected patients with the location of the treatment beams modified to reflect typical setup variations. Results: The CLD measured on the port films was within 3 mm of that prescribed on the simulator film in 43% (74 of 172) of the port films. The variation was 3-5 mm in 26%, 5-10 mm in 25%, and >10 mm in 6%. The height of the lung shadow correlated with the percentage of lung volume included in the radiation field (r 2 = 0.6). Typical variations in treatment setup resulted in ≤5% fluctuation in the absolute volume of ipsilateral lung irradiated. Conclusion: The current immobilization system used in our clinic provides a clinically acceptable reproducibility of patient setup. The height of the lung shadow is reasonably well correlated with the percentage of irradiated lung volume. During a typical 5-week course of radiotherapy, the ipsilateral irradiated lung volume fluctuates <5%

  1. Calculation errors of Set-up in patients with tumor location of prostate. Exploratory study; Calculo de errores de Set-up en pacientes con localizacion tumoral de prostata. Estudio exploratorio

    Energy Technology Data Exchange (ETDEWEB)

    Donis Gil, S.; Robayna Duque, B. E.; Jimenez Sosa, A.; Hernandez Armas, O.; Gonzalez Martin, A. E.; Hernandez Armas, J.

    2013-07-01

    The calculation of SM is done from errors in positioning (set-up). These errors are calculated from movements in 3D of the patient. This paper is an exploratory study of 20 patients with tumor location of prostate in which errors of set-up for two protocols of work are evaluated. (Author)

  2. Exposure setups for laboratory animals and volunteer studies using body-mounted antennas

    International Nuclear Information System (INIS)

    Bahr, A.; Adami, C.; Bolz, T.; Rennings, A.; Dorn, H.; Ruettiger, L.

    2007-01-01

    For two different in vivo exposure setups body-mounted antenna systems have been designed. The first setup is designed for investigation of volunteers during simulated mobile phone usage. The setup consists of a dual-band antenna for GSM/WCDMA with enhanced carrying properties, which enables exposure for at least 8 h a day. The 10 g averaged localised SAR - normalised to an antenna input power of 1 W - measured in the flat phantom area of the SAM phantom amounts to 7.82 mW g -1 (900 MHz) and 10.98 mW g -1 (1966 MHz). The second exposure setup is used for a laboratory behavioural study on rats. The design goal was a localised, well-defined SAR distribution inside the animals' heads at 900 MHz. To fulfil the biological requirements, a loop antenna was developed. For tissues around the ears, a localised SAR value of 50.12 W kg -1 averaged over a mass of 2.2 g for an antenna input power of 1 W is obtained. (authors)

  3. Electrical alignment of antenna coordinate system in a planar near-field setup

    DEFF Research Database (Denmark)

    Mynster, Anders P.; Nielsen, Jeppe Majlund; Pivnenko, Sergey

    2011-01-01

    In this paper, a simple and efficient electrical alignment procedure known as flip-test is adapted and applied to check and correct two errors in the mechanical setup of a planar near-field system: the mis-pointing of the z-axis of the antenna coordinate system with respect to the scan plane...... and the displacement of the center point of the scan plane with respect to the z-axis of the antenna coordinate system. Simulations of the errors and their correction algorithms were carried out with different models of antennas composed of Hertzian dipoles and an optimum algorithm was then selected. The proposed...

  4. Three-dimensional micro-XRF investigations of paint layers with a tabletop setup

    International Nuclear Information System (INIS)

    Kanngiesser, Birgit; Malzer, Wolfgang; Rodriguez, Alexis Fuentes; Reiche, Ina

    2005-01-01

    The non-destructive investigation of art and archaeological objects with depth sensitivity is now possible using 3D micro-XRF spectroscopy. More detailed answers for questions on painting techniques, on the pigment palette, on the production processes and indirectly on dating or provenancing of objects are accessible now. This was already illustrated by the investigation of Mughal miniatures with a confocal setup at the synchrotron source BESSY. In this paper we demonstrate the feasibility of 3D micro-XRF spectroscopy with a tabletop setup and discuss its sensitivity in comparison to the synchrotron-based setup. Investigated objects are glass standards and also prepared paint layers. Perspectives for other types of studies are proposed

  5. A Geant4 simulation package for the TASISpec experimental detector setup

    Energy Technology Data Exchange (ETDEWEB)

    Sarmiento, L.G., E-mail: lgsarmientop@unal.edu.co [Universidad Nacional de Colombia, Bogota D.C. 111321 (Colombia); Lund University, S-22100 Lund (Sweden); Andersson, L.-L. [University of Liverpool, Oliver Lodge Laboratory, Liverpool L69 7ZE (United Kingdom); Rudolph, D. [Lund University, S-22100 Lund (Sweden)

    2012-03-01

    The experimental detector setup TASISpec (TA SCA in Small Image mode Spectroscopy) comprises composite Ge- and highly segmented Si-detectors. The setup is constructed to provide multi-coincidence spectroscopic data between {gamma}-rays, X-rays, conversion electrons, fission fragments, and {alpha}-particles for heavy and superheavy elements (Z{>=}100). The full array has been virtually constructed using the Geant4 simulation toolkit. The simulations will not only be used to explore the possibilities of the detector setup itself. More important, however, they will also shed light on the nuclear structure of the heaviest elements. This can be done by comparing the simulated detector response of complex decay modes with the experimental data. Such an iterative or 'self-consistent' way to understand experimental observables will provide more reliability when disentangling the data and deducing experimental decay schemes.

  6. A two-shift optimisation of the 'no action level' setup correction protocol

    International Nuclear Information System (INIS)

    Fox, C.; Fisher, R.

    2004-01-01

    Full text: As electronic portal imaging equipment becomes more common, many radiotherapy centres now have the ability to collect patient treatment position deviation values. One commonly used off-line set-up correction protocol for calculating patient setup corrections is the 'no action level' (NAL) protocol. This paper proposes a two-shift approach and calculates the number of images required for minimum systematic error. Patient data is used in a simulation to confirm this approach. Patient treatment position deviations were available for all treatment sessions for a large group of patients undergoing radiation therapy for prostate. Thirty of these patients were selected. The patient position at treatment and all isocentre shifts made were recorded in the treatment notes. These were used to simulate the effect of the NAL protocol using a range of image numbers as the basis of the set-up correction. As Bortfeld et al noted, there is an error minimum that can be observed beyond which the mean radial systematic set-up error increases slowly with an increase in the number of images used. An enhancement to the NAL was proposed in which the patient's position is corrected on two occasions; once early in the treatment schedule, and again after more images have been collected. The expectation value of the set-up error for this two-shift NAL was found and minimised. The optimum staging for the two-shift NAL for the prostate patients was to image for a total of 9 sessions and to shift the patient after 3 sessions and 9 sessions. The thirty patients showed an uncorrected mean radial setup error of 0.65cm. In this simulation this was corrected to 0.26cm by application of the NAL using 5 images and to 0.17 cm using the two shift NAL with shifts after three and nine images. In situations where staff can manage the workload of collecting and analysing portal images for nine sessions for each patient, the two-shift NAL will result in a high level of set-up accuracy. Copyright

  7. Evaluation of Setup Error Correction for Patients Using On Board Imager in Image Guided Radiation Therapy

    International Nuclear Information System (INIS)

    Kang, Soo Man

    2008-01-01

    To reduce side effects in image guided radiation therapy (IGRT) and to improve the quality of life of patients, also to meet accurate SETUP condition for patients, the various SETUP correction conditions were compared and evaluated by using on board imager (OBI) during the SETUP. Each 30 cases of the head, the neck, the chest, the belly, and the pelvis in 150 cases of IGRT patients was corrected after confirmation by using OBI at every 2-3 day. Also, the difference of the SETUP through the skin-marker and the anatomic SETUP through the OBI was evaluated. General SETUP errors (Transverse, Coronal, Sagittal) through the OBI at original SETUP position were Head and Neck: 1.3 mm, Brain: 2 mm, Chest: 3 mm, Abdoman: 3.7 mm, Pelvis: 4 mm. The patients with more that 3 mm in the error range were observed in the correction devices and the patient motions by confirming in treatment room. Moreover, in the case of female patients, the result came from the position of hairs during the Head and Neck, Brain tumor. Therefore, after another SETUP in each cases of over 3 mm in the error range, the treatment was carried out. Mean error values of each parts estimated after the correction were 1 mm for the head, 1.2 mm for the neck, 2.5 mm for the chest, 2.5 mm for the belly, and 2.6 mm for the pelvis. The result showed the correction of SETUP for each treatment through OBI is extremely difficult because of the importance of SETUP in radiation treatment. However, by establishing the average standard of the patients from this research result, the better patient satisfaction and treatment results could be obtained.

  8. Evaluation of Setup Error Correction for Patients Using On Board Imager in Image Guided Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Soo Man [Dept. of Radiation Oncology, Kosin University Gospel Hospital, Busan (Korea, Republic of)

    2008-09-15

    To reduce side effects in image guided radiation therapy (IGRT) and to improve the quality of life of patients, also to meet accurate SETUP condition for patients, the various SETUP correction conditions were compared and evaluated by using on board imager (OBI) during the SETUP. Each 30 cases of the head, the neck, the chest, the belly, and the pelvis in 150 cases of IGRT patients was corrected after confirmation by using OBI at every 2-3 day. Also, the difference of the SETUP through the skin-marker and the anatomic SETUP through the OBI was evaluated. General SETUP errors (Transverse, Coronal, Sagittal) through the OBI at original SETUP position were Head and Neck: 1.3 mm, Brain: 2 mm, Chest: 3 mm, Abdoman: 3.7 mm, Pelvis: 4 mm. The patients with more that 3 mm in the error range were observed in the correction devices and the patient motions by confirming in treatment room. Moreover, in the case of female patients, the result came from the position of hairs during the Head and Neck, Brain tumor. Therefore, after another SETUP in each cases of over 3 mm in the error range, the treatment was carried out. Mean error values of each parts estimated after the correction were 1 mm for the head, 1.2 mm for the neck, 2.5 mm for the chest, 2.5 mm for the belly, and 2.6 mm for the pelvis. The result showed the correction of SETUP for each treatment through OBI is extremely difficult because of the importance of SETUP in radiation treatment. However, by establishing the average standard of the patients from this research result, the better patient satisfaction and treatment results could be obtained.

  9. Plasma Deflection Test Setup for E-Sail Propulsion Concept

    Science.gov (United States)

    Andersen, Allen; Vaughn, Jason; Schneider, Todd; Wright, Ken

    2016-01-01

    The Electronic Sail or E-Sail is a novel propulsion concept based on momentum exchange between fast solar wind protons and the plasma sheath of long positively charged conductors comprising the E-Sail. The effective sail area increases with decreasing plasma density allowing an E-Sail craft to continue to accelerate at predicted ranges well beyond the capabilities of existing electronic or chemical propulsion spacecraft. While negatively charged conductors in plasmas have been extensively studied and flown, the interaction between plasma and a positively charged conductor is not well studied. We present a plasma deflection test method using a differential ion flux probe (DIFP). The DIFP measures the angle and energy of incident ions. The plasma sheath around a charged body can measured by comparing the angular distribution of ions with and without a positively charged test body. These test results will be used to evaluate numerical calculations of expected thrust per unit length of conductor in the solar wind plasma. This work was supported by a NASA Space Technology Research Fellowship.

  10. Virtual instrument automation of ion channeling setup for 1.7 MV tandetron accelerator

    International Nuclear Information System (INIS)

    Suresh, K.; Sundaravel, B.; Panigrahi, B.K.; Nair, K.G.M.; Viswanathan, B.

    2004-01-01

    A virtual instrument based automated ion channeling experimental setup has been developed and implemented in a 1.7 MV tandetron accelerator. Automation of the PC based setup is done using a windows based virtual instrument software allowing the setup to be easily ported between different computer operating systems. The virtual instrument software has been chosen to achieve quick and easy development of versatile, multi-purpose user friendly graphical interface for carrying out channeling experiments. The software has been modular designed to provide independent control of the stepper motors for fixing the sample at any user defined orientation, running and on-line display of azimuthal and tilt angular scans, auto storage of the angular scan data. Using this automated setup, the crystallographic axis of the sample can be aligned with the incident ion beam rapidly minimizing the beam damages to the sample. A standard single crystalline GaAs(100) has been characterized with this set up using 2 MeV He ++ ion beam. The crystalline quality (χ min ) and channeling half angle (ψ 1sol2 ) are measured to be 3.7% and 0.48 deg., respectively, which are close to the theoretical values. Salient features, working principles and design details of the automated setup are discussed in this paper

  11. Hybrid Testing of Composite Structures with Single-Axis Control

    DEFF Research Database (Denmark)

    Waldbjørn, Jacob Paamand; Høgh, Jacob Herold; Stang, Henrik

    2013-01-01

    Correlation (DIC) is therefore implemented for displacement control of the experimental setup. The hybrid testing setup was verified on a multicomponent structure consisting of a beam loaded in three point bending and a numerical structure of a frame. Furthermore, the stability of the hybrid testing loop......Hybrid testing is a substructuring technique where a structure is emulated by modelling a part of it in a numerical model while testing the remainder experimentally. Previous research in hybrid testing has been performed on multi-component structures e.g. damping fixtures, however in this paper...... a hybrid testing platform is introduced for single-component hybrid testing. In this case, the boundary between the numerical model and experimental setup is defined by multiple Degrees-Of-Freedoms (DOFs) which highly complicate the transferring of response between the two substructures. Digital Image...

  12. Effect of patient setup errors on simultaneously integrated boost head and neck IMRT treatment plans

    International Nuclear Information System (INIS)

    Siebers, Jeffrey V.; Keall, Paul J.; Wu Qiuwen; Williamson, Jeffrey F.; Schmidt-Ullrich, Rupert K.

    2005-01-01

    Purpose: The purpose of this study is to determine dose delivery errors that could result from random and systematic setup errors for head-and-neck patients treated using the simultaneous integrated boost (SIB)-intensity-modulated radiation therapy (IMRT) technique. Methods and Materials: Twenty-four patients who participated in an intramural Phase I/II parotid-sparing IMRT dose-escalation protocol using the SIB treatment technique had their dose distributions reevaluated to assess the impact of random and systematic setup errors. The dosimetric effect of random setup error was simulated by convolving the two-dimensional fluence distribution of each beam with the random setup error probability density distribution. Random setup errors of σ = 1, 3, and 5 mm were simulated. Systematic setup errors were simulated by randomly shifting the patient isocenter along each of the three Cartesian axes, with each shift selected from a normal distribution. Systematic setup error distributions with Σ = 1.5 and 3.0 mm along each axis were simulated. Combined systematic and random setup errors were simulated for σ = Σ = 1.5 and 3.0 mm along each axis. For each dose calculation, the gross tumor volume (GTV) received by 98% of the volume (D 98 ), clinical target volume (CTV) D 90 , nodes D 90 , cord D 2 , and parotid D 50 and parotid mean dose were evaluated with respect to the plan used for treatment for the structure dose and for an effective planning target volume (PTV) with a 3-mm margin. Results: Simultaneous integrated boost-IMRT head-and-neck treatment plans were found to be less sensitive to random setup errors than to systematic setup errors. For random-only errors, errors exceeded 3% only when the random setup error σ exceeded 3 mm. Simulated systematic setup errors with Σ = 1.5 mm resulted in approximately 10% of plan having more than a 3% dose error, whereas a Σ = 3.0 mm resulted in half of the plans having more than a 3% dose error and 28% with a 5% dose error

  13. Beta-spectroscopy of long lived nuclides with a PIPS detector-setup

    Directory of Open Access Journals (Sweden)

    Domula Alexander R.

    2017-01-01

    Full Text Available Several applications in modern nuclear physics, research and engineering are limited by a lack of precise knowledge in spectral shape data for beta-decays. Specifically the interest aims to study spectral data for forbidden decays with respectively long half-lives, which is one of the central activities of our group. For the investigation of those rare beta-decays the group operates a setup of six PIPS detectors in a vacuum chamber built out of low-radioactivity materials. In the long term the setup will be used as low-background-detector for the investigation of rare beta-decays. In order to reduce the measuring-background a muon veto was installed. The characterization of the setup in the energy-range from 20..1000 keV using conversion-electrons is described. A set of useful calibration-nuclides was established to determine energy calibration and efficiencies.

  14. Comparison of prostate set-up accuracy and margins with off-line bony anatomy corrections and online implanted fiducial-based corrections.

    Science.gov (United States)

    Greer, P B; Dahl, K; Ebert, M A; Wratten, C; White, M; Denham, J W

    2008-10-01

    The aim of the study was to determine prostate set-up accuracy and set-up margins with off-line bony anatomy-based imaging protocols, compared with online implanted fiducial marker-based imaging with daily corrections. Eleven patients were treated with implanted prostate fiducial markers and online set-up corrections. Pretreatment orthogonal electronic portal images were acquired to determine couch shifts and verification images were acquired during treatment to measure residual set-up error. The prostate set-up errors that would result from skin marker set-up, off-line bony anatomy-based protocols and online fiducial marker-based corrections were determined. Set-up margins were calculated for each set-up technique using the percentage of encompassed isocentres and a margin recipe. The prostate systematic set-up errors in the medial-lateral, superior-inferior and anterior-posterior directions for skin marker set-up were 2.2, 3.6 and 4.5 mm (1 standard deviation). For our bony anatomy-based off-line protocol the prostate systematic set-up errors were 1.6, 2.5 and 4.4 mm. For the online fiducial based set-up the results were 0.5, 1.4 and 1.4 mm. A prostate systematic error of 10.2 mm was uncorrected by the off-line bone protocol in one patient. Set-up margins calculated to encompass 98% of prostate set-up shifts were 11-14 mm with bone off-line set-up and 4-7 mm with online fiducial markers. Margins from the van Herk margin recipe were generally 1-2 mm smaller. Bony anatomy-based set-up protocols improve the group prostate set-up error compared with skin marks; however, large prostate systematic errors can remain undetected or systematic errors increased for individual patients. The margin required for set-up errors was found to be 10-15 mm unless implanted fiducial markers are available for treatment guidance.

  15. Revisiting wild stocks of black lip oyster Pinctada margaritifera in the Tuamotu Archipelago: The case of Ahe and Takaroa atolls and implications for the cultured pearl industry

    Science.gov (United States)

    Andréfouët, Serge; Thomas, Yoann; Dumas, Franck; Lo, Cédrik

    2016-12-01

    Spat collecting of the black lip oyster (Pinctada margaritifera) is the foundation of cultured black pearl production, the second source of income for French Polynesia. To understand spat collecting temporal and spatial variations, larval supply and its origin need to be characterized. To achieve this, it is necessary to account for the stock of oysters, its distribution and population characteristics (size distribution, sex-ratio). While the farmed stock in concessions can be easily characterized, the wild stock is elusive. Here, we investigate the distribution and population structure of the wild stock of Ahe and Takaroa atolls using fine-scale bathymetry and in situ census data. Stocks were surprisingly low (∼666,000 and ∼1,030,000 oysters for Ahe and Takaroa respectively) considering these two atolls have both been very successful spat collecting atolls in the past. Furthermore, in Ahe atoll, wild populations are aging with a dominant but small female population. Comparison with the cultured stock population (∼14 millions oysters) and its dominant young male population suggests that to maximize larval supply and spat collecting on the long term, it would be useful to increase the number of females in selected sanctuaries. We discuss the implication of our findings for the long-term management of stocks and for spat collection in pearl farming atolls, and for on-going numerical modelling studies on larval dispersal.

  16. Development of an experimental setup for analyzing the influence of Magnus effect on the performance of airfoil

    Science.gov (United States)

    Aktharuzzaman, Md; Sarker, Md. Samad; Safa, Wasiul; Sharah, Nahreen; Salam, Md. Abdus

    2017-12-01

    Magnus effect is a phenomenon where pressure difference is created according to Bernoulli's effect due to induced velocity changes caused by a rotating object in a fluid. Using this concept, the idea of delaying boundary layer separation on airfoil by providing moving surface boundary layer control has been developed. In order to analyze the influence of Magnus effect on the aerodynamic performance of an airfoil, there is no alternative of developing an experimental setup. This paper aims to develop such an experimental setup which will be capable of analyzing the influence of Magnus effect on both symmetric and asymmetric airfoils by placing a cylinder at the leading edge. To provide arrangements for a rotating cylinder at the leading edge of airfoil, necessary modifications and additions have been done in the test section of an AF100 subsonic wind tunnel.

  17. Search for hybrid baryons with CLAS12 experimental setup

    Energy Technology Data Exchange (ETDEWEB)

    Lanza, Lucille [Univ. degli Studi di Roma Tor Vergata (Italy); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2017-03-01

    It is crucial to study the meson electroproduction in the kinematic region dominated by the formation of resonances. CLAS12 setup in Hall B at Jefferson Lab is particularly suitable for this task, since it is able to detect scattered electrons at low polar angles thanks to the Forward Tagger (FT) component. The process that we propose to study is ep → e'K+Λ, where the electron beam will be provided by the CEBAF accelerator with energies of 6.6, 8.8, and 11 GeV. This thesis work describes the setup and calibration of the FT calorimeter and the studies related to the search of hybrid baryons through the measurement of the K+ Λ electroproduction cross section.

  18. Automated setup for spray assisted layer-by-layer deposition.

    Science.gov (United States)

    Mundra, Paul; Otto, Tobias; Gaponik, Nikolai; Eychmüller, Alexander

    2013-07-01

    The design for a setup allowing the layer-by-layer (LbL) assembly of thin films consisting of various colloidal materials is presented. The proposed system utilizes the spray-assisted LbL approach and is capable of autonomously producing films. It provides advantages to existing LbL procedures in terms of process speed and applicability. The setup offers several features that are advantageous for routine operation like an actuated sample holder, stainless steel spraying nozzles, or an optical liquid detection system. The applicability is demonstrated by the preparation of films containing semiconductor nanoparticles, namely, CdSe∕CdS quantum dots and a polyelectolyte. The films of this type are of potential interest for applications in optoelectronic devices such as light-emitting diodes or solar cells.

  19. Integration Tests of the Muon System

    CERN Multimedia

    Cerutti, F; Palestini, S

    A complex large-size prototype of the Muon system is installed in the test area H8B in Prévessin; the set-up includes chambers belonging to the three layers of the Barrel Spectrometer (on the right in Figure 1), and chambers belonging to one octant of the End Cap Spectrometer (center and left side of Figure 1). Figure 1: Set-up of the Muon spectrometer integration test. The installation accurately reproduces the geometry of regions of the ATLAS Muon Spectrometer, with the H8 beam-line crossing the detectors at positions/angles corresponding to particles with polar angle of 75 ± 4 and 15 ± 4 degrees, respectively for the Barrel and the End Cap. A comprehensive test program is being carried out with this set-up, ranging from tests of support frames (octant of the MDT BigWheel and of the SmallWheel) and of handling/installation of tracking chambers, to real-size tests of the alignment systems, together with accurate studies of performance and calibration of the precision chambers, and with develo...

  20. A simple setup for neutron tomography at the Portuguese nuclear research reactor

    International Nuclear Information System (INIS)

    Pereira, M.A. Stanojev; Marques, J.G.; Pugliesi, R.

    2012-01-01

    A simple setup for neutron radiography and tomography was recently installed at the Portuguese Research Reactor. The objective of this work was to determine the operational characteristics of the installed setup, namely the irradiation time to obtain the best dynamic range for individual images and the spatial resolution. The performance of the equipment was demonstrated by imaging a fragment of a seventeenth-century decorative tile. (author)

  1. SU-E-J-217: Accuracy Comparison Between Surface and Volumetric Registrations for Patient Setup of Head and Neck Radiation Therapy

    International Nuclear Information System (INIS)

    Kim, Y; Li, R; Na, Y; Jenkins, C; Xing, L; Lee, R

    2014-01-01

    Purpose: Optical surface imaging has been applied to radiation therapy patient setup. This study aims to investigate the accuracy of the surface registration of the optical surface imaging compared with that of the conventional method of volumetric registration for patient setup in head and neck radiation therapy. Methods: Clinical datasets of planning CT and treatment Cone Beam CT (CBCT) were used to compare the surface and volumetric registrations in radiation therapy patient setup. The Iterative Closest Points based on point-plane closest method was implemented for surface registration. We employed 3D Slicer for rigid volumetric registration of planning CT and treatment CBCT. 6 parameters of registration results (3 rotations and 3 translations) were obtained by the two registration methods, and the results were compared. Digital simulation tests in ideal cases were also performed to validate each registration method. Results: Digital simulation tests showed that both of the registration methods were accurate and robust enough to compare the registration results. In experiments with the actual clinical data, the results showed considerable deviation between the surface and volumetric registrations. The average root mean squared translational error was 2.7 mm and the maximum translational error was 5.2 mm. Conclusion: The deviation between the surface and volumetric registrations was considerable. Special caution should be taken in using an optical surface imaging. To ensure the accuracy of optical surface imaging in radiation therapy patient setup, additional measures are required. This research was supported in part by the KIST institutional program (2E24551), the Industrial Strategic technology development program (10035495) funded by the Ministry of Trade, Industry and Energy (MOTIE, KOREA), and the Radiation Safety Research Programs (1305033) through the Nuclear Safety and Security Commission, and the NIH (R01EB016777)

  2. SU-E-J-217: Accuracy Comparison Between Surface and Volumetric Registrations for Patient Setup of Head and Neck Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y [Stanford University School of Medicine, Stanford, CA (United States); Korea Institute of Science and Technology, Seoul (Korea, Republic of); Li, R; Na, Y; Jenkins, C; Xing, L [Stanford University School of Medicine, Stanford, CA (United States); Lee, R [Ewha Womans University, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: Optical surface imaging has been applied to radiation therapy patient setup. This study aims to investigate the accuracy of the surface registration of the optical surface imaging compared with that of the conventional method of volumetric registration for patient setup in head and neck radiation therapy. Methods: Clinical datasets of planning CT and treatment Cone Beam CT (CBCT) were used to compare the surface and volumetric registrations in radiation therapy patient setup. The Iterative Closest Points based on point-plane closest method was implemented for surface registration. We employed 3D Slicer for rigid volumetric registration of planning CT and treatment CBCT. 6 parameters of registration results (3 rotations and 3 translations) were obtained by the two registration methods, and the results were compared. Digital simulation tests in ideal cases were also performed to validate each registration method. Results: Digital simulation tests showed that both of the registration methods were accurate and robust enough to compare the registration results. In experiments with the actual clinical data, the results showed considerable deviation between the surface and volumetric registrations. The average root mean squared translational error was 2.7 mm and the maximum translational error was 5.2 mm. Conclusion: The deviation between the surface and volumetric registrations was considerable. Special caution should be taken in using an optical surface imaging. To ensure the accuracy of optical surface imaging in radiation therapy patient setup, additional measures are required. This research was supported in part by the KIST institutional program (2E24551), the Industrial Strategic technology development program (10035495) funded by the Ministry of Trade, Industry and Energy (MOTIE, KOREA), and the Radiation Safety Research Programs (1305033) through the Nuclear Safety and Security Commission, and the NIH (R01EB016777)

  3. Intrafractional Target Motions and Uncertainties of Treatment Setup Reference Systems in Accelerated Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Yue, Ning J.; Goyal, Sharad; Zhou Jinghao; Khan, Atif J.; Haffty, Bruce G.

    2011-01-01

    Purpose: This study investigated the magnitude of intrafractional motion and level of accuracy of various setup strategies in accelerated partial breast irradiation (APBI) using three-dimensional conformal external beam radiotherapy. Methods and Materials: At lumpectomy, gold fiducial markers were strategically sutured to the surrounding walls of the cavity. Weekly fluoroscopy imaging was conducted at treatment to investigate the respiration-induced target motions. Daily pre- and post-RT kV imaging was performed, and images were matched to digitally reconstructed radiographs based on bony anatomy and fiducial markers, respectively, to determine the intrafractional motion magnitudes over the course of treatment. The positioning differences of the laser tattoo- and the bony anatomy-based setups compared with those of the marker-based setup (benchmark) were also determined. The study included 21 patients. Results: Although lung exhibited significant motion, the average marker motion amplitude on the fluoroscopic image was about 1 mm. Over a typical treatment time period, average intrafractional motion magnitude was 4.2 mm and 2.6 mm based on the marker and bony anatomy matching, respectively. The bony anatomy- and laser tattoo-based interfractional setup errors, with respect to the fiducial marker-based setup, were 7.1 and 9.0 mm, respectively. Conclusions: Respiration has limited effects on the target motion during APBI. Bony anatomy-based treatment setup improves the accuracy relative to that of the laser tattoo-based setup approach. Since fiducial markers are sutured directly to the surgical cavity, the marker-based approach can further improve the interfractional setup accuracy. On average, a seroma cavity exhibits intrafractional motion of more than 4 mm, a magnitude that is larger than that which is otherwise derived based on bony anatomy matching. A seroma-specific marker-based approach has the potential to improve treatment accuracy by taking the true inter

  4. LS1 Report: A brand new set-up for ASACUSA-CUSP

    CERN Multimedia

    Antonella Del Rosso

    2014-01-01

    ASACUSA is running for the first time with a totally new set-up. Three new vital instruments have been designed, produced and installed during LS1 in addition to several other major modifications. The collaboration is now ready to perform the first high-precision measurement of the hyperfine structure of antihydrogen – a study that aims at comparing the inner properties of matter and antimatter.   The ASACUSA set-up. The ASACUSA-CUSP collaboration comprises about 30 scientists from various institutes in Europe and Japan. Because of the Japanese contribution, the experiment is often known by its Japanese pronunciation, the experiment’s logo is in Japanese, and the logbook uses Japanese time! This year, for the first time, the experiment is running with a completely new set-up, which now includes a new superconducting double cusp magnet, a new tracking detector and a new final antihydrogen detector. “The magnet is the heart of the ASACUSA experiment,” expl...

  5. Comparison of prostate set-up accuracy and margins with off-line bony anatomy corrections and online implanted fiducial-based corrections

    International Nuclear Information System (INIS)

    Greer, P. B.; Dahl, K.; Ebert, M. A.; Wratten, C.; White, M.; Denham, K. W.

    2008-01-01

    Full text: The aim of the study was to determine prostate set-up accuracy and set-up margins with off-line bony anatomy-based imaging protocols, compared with online implanted fiducial marker-based imaging with daily corrections. Eleven patients were treated with implanted prostate fiducial markers and online set-up corrections. Pretreatment orthogonal electronic portal images were acquired to determine couch shifts and verification images were acquired during treatment to measure residual set-up error. The prostate set-up errors that would result from skin marker set-up, off-line bony anatomy-based protocols and online fiducial marker-based corrections were determined. Set-up margins were calculated for each set-up technique using the percentage of encompassed isocentres land a margin recipe. The prostate systematic set-up errors in the medial-lateral, superior-inferior and anterior-I posterior directions for skin marker set-up were 2.2, 3.6 and 4.5 mm (1 standard deviation). For our bony anatomy-I based off-line protocol the prostate systematic set-up errors were 1.6, 2.5 and 4.4 mm. For the online fiducial based set-up the results were 0.5, 1.4 and 1.4 mm. A prostate systematic error of 10.2 mm was uncorrected by the off-line bone protocol in one patient. Set-up margins calculated to encompass 98% of prostate set-up shifts were 111-14 mm with bone off-line set-up and 4-7 mm with online fiducial markers. Margins from the van Herk margin I recipe were generally 1-2 mm smaller. Bony anatomy-based set-up protocols improve the group prostate set-up error compared with skin marks; however, large prostate systematic errors can remain undetected or systematic (errors increased for individual patients. The margin required for set-up errors was found to be 10-15 mm unless I implanted fiducial markers are available for treatment guidance.

  6. Laser and beta source setup characterization of 3D-DDTC detectors fabricated at FBK-irst

    Energy Technology Data Exchange (ETDEWEB)

    Zoboli, A. [INFN, Sezione di Padova (Gruppo Collegato di Trento), and Dipartimento di Ingegneria e Scienza dell' Informazione, Universita di Trento, Via Sommarive, 14, I-38050 Povo (Trento) (Italy)], E-mail: zoboli@disi.unitn.it; Dalla Betta, G.-F. [INFN, Sezione di Padova (Gruppo Collegato di Trento), and Dipartimento di Ingegneria e Scienza dell' Informazione, Universita di Trento, Via Sommarive, 14, I-38050 Povo (Trento) (Italy); Boscardin, M. [Fondazione Bruno Kessler, Centro per i Materiali e i Microsistemi, Via Sommarive, 18, I-38050 Povo (Trento) (Italy); Bosisio, L. [Dip. di Fisica e INFN, Universita di Trieste, I-34127, Trieste (Italy); Eckert, S.; Kuehn, S.; Parzefall, U. [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Piemonte, C.; Ronchin, S.; Zorzi, N. [Fondazione Bruno Kessler, Centro per i Materiali e i Microsistemi, Via Sommarive, 18, I-38050 Povo (Trento) (Italy)

    2009-06-01

    We report on the functional characterization of the first batch of 3D Double-Sided Double Type Column (3D-DDTC) detectors fabricated at FBK, Trento. This detector concept represents the evolution of the previous 3D-STC detectors towards full 3D detectors, and is expected to achieve a performance which is comparable to standard 3D detectors, but with a simpler fabrication process. Measurements were performed on detectors in the microstrip configuration coupled to the ATLAS ABCD3T binary readout. This paper reports spatially resolved signal efficiency tests made with a pulsed infrared laser setup and charge collection efficiency tests made with a Beta source.

  7. Laser and beta source setup characterization of 3D-DDTC detectors fabricated at FBK-irst

    International Nuclear Information System (INIS)

    Zoboli, A.; Dalla Betta, G.-F.; Boscardin, M.; Bosisio, L.; Eckert, S.; Kuehn, S.; Parzefall, U.; Piemonte, C.; Ronchin, S.; Zorzi, N.

    2009-01-01

    We report on the functional characterization of the first batch of 3D Double-Sided Double Type Column (3D-DDTC) detectors fabricated at FBK, Trento. This detector concept represents the evolution of the previous 3D-STC detectors towards full 3D detectors, and is expected to achieve a performance which is comparable to standard 3D detectors, but with a simpler fabrication process. Measurements were performed on detectors in the microstrip configuration coupled to the ATLAS ABCD3T binary readout. This paper reports spatially resolved signal efficiency tests made with a pulsed infrared laser setup and charge collection efficiency tests made with a Beta source.

  8. Efficient on-line setup correction strategies using plan-intent functions

    International Nuclear Information System (INIS)

    Keller, Harry; Jaffray, David A.; Rosewall, Tara; White, Elizabeth

    2006-01-01

    With the introduction of image-guided radiation therapy (IGRT) delivery systems on-line set-up correction strategies have gained in popularity. Usually, the correction workload of these strategies is high compared to off-line strategies as daily setup corrections have to be performed based on a predefined action level. In this work, it is proposed that on-line strategies must not only be judged in terms of workload but also in terms of efficacy. While workload can be easily predicted for such strategies, the efficacy must ultimately reflect the efficiency with which the original treatment plan intent is met. The purpose of this work is to investigate the tradeoff between workload and efficacy of three different on-line set-up correction strategies: The common fixed action level strategy and two novel on-line setup correction strategies, i.e., a dose-volume histogram (DVH) constraint and an equivalent uniform dose (EUD) score strategy that aim directly for better compliance with original treatment plan intent. All strategies were reformulated in terms of a score function that reflected treatment plan intent. A retrospective study was conducted on 5 prostate patients (7-field conformal, 79.8 Gy, 42 fractions). PTV margins were 10 mm except in the posterior direction (7 mm). The original treatment plan intent for these patients was defined using a set of DVH constraints. The results show that the on-line setup correction strategy based on a fixed action level of 3 mm resulted in a considerable correction workload. For larger action levels, a dose benefit (in terms of EUD) in the rectum and bladder was observed for all patients which is clinically ''fortuitous'' but difficult to take advantage of. In contrast, the application of the two novel strategies generally resulted in a controlled decrease of the dose to the rectum and the bladder with a smaller workload. It is concluded that using information about target anatomy and the planned dose distribution allows the

  9. An economic production model for time dependent demand with rework and multiple production setups

    Directory of Open Access Journals (Sweden)

    S.R. Singh

    2014-04-01

    Full Text Available In this paper, we present a model for time dependent demand with multiple productions and rework setups. Production is demand dependent and greater than the demand rate. Production facility produces items in m production setups and one rework setup (m, 1 policy. The major reason of reverse logistic and green supply chain is rework, so it reduces the cost of production and other ecological problems. Most of the researchers developed a rework model without deteriorating items. A numerical example and sensitivity analysis is shown to describe the model.

  10. The new cold neutron tomography set-up at SINQ

    CERN Document Server

    Baechler, S; Cauwels, P; Dierick, M; Jolie, J; Materna, T; Mondelaers, W

    2002-01-01

    A new cold neutron tomography set-up is operational at the neutron spallation source SINQ of the Paul Scherrer Institute (PSI) in Villigen, Switzerland. The detection system is based on a sup 6 LiF/ZnS:Ag conversion screen and a CCD camera. Several tests have been carried out to characterize the quality of the tomography system, such as homogeneity, reproducibility, L/D-ratio and spatial resolution. The high flux and the good efficiency of the detector lead to very short exposure times. Thus, a typical set of tomography scans can be performed in only 20 min. Then, 3D computed tomography objects were calculated using the filtered back-projection reconstruction method. Initial results of various samples show that cold neutron tomography can be a useful tool for industry, geology and dentistry. Furthermore, suitable applications can be found in the field of archaeology.

  11. Over-relaxation phenomena during the set-up of RFP plasmas

    International Nuclear Information System (INIS)

    Nordlund, P.; Mazur, S.

    1995-03-01

    Experiments on the Extrap T1 reversed field pinch have shown that the formation of the RFP configuration is quite sensitive to the relative programming of the toroidal field and ohmic heating circuits. In this paper, new measurements of the evolution of the current density profile and of the spectral structure of the fluctuations during the set-up phase of RFP plasmas in the T1 experiment are presented. These measurements improve the understanding of the role of different spectral components in the dynamics of RFP formation. Under unfavourable (slow) set-up conditions, comparatively high energy is accumulated in m = 1 internal kinks prior to reversal of the edge toroidal fields. At reversal, nonlinearly driven m = 0 modes trigger a rapid broadening of the m = 1 spectrum. This behaviour is associated with a violent suppression of the current density in the core leading to an over-relaxation of the discharge involving a hollowing of the parallel current density profile. The over-relaxation phenomenon increases the volt-second consumption and plasma/wall interaction during RFP set-up, and degrades the flat-top discharge performance. 15 refs, 5 figs, 1 tab

  12. Over-relaxation phenomena during the set-up of RFP plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Nordlund, P.; Mazur, S.

    1995-03-01

    Experiments on the Extrap T1 reversed field pinch have shown that the formation of the RFP configuration is quite sensitive to the relative programming of the toroidal field and ohmic heating circuits. In this paper, new measurements of the evolution of the current density profile and of the spectral structure of the fluctuations during the set-up phase of RFP plasmas in the T1 experiment are presented. These measurements improve the understanding of the role of different spectral components in the dynamics of RFP formation. Under unfavourable (slow) set-up conditions, comparatively high energy is accumulated in m = 1 internal kinks prior to reversal of the edge toroidal fields. At reversal, nonlinearly driven m = 0 modes trigger a rapid broadening of the m = 1 spectrum. This behaviour is associated with a violent suppression of the current density in the core leading to an over-relaxation of the discharge involving a hollowing of the parallel current density profile. The over-relaxation phenomenon increases the volt-second consumption and plasma/wall interaction during RFP set-up, and degrades the flat-top discharge performance. 15 refs, 5 figs, 1 tab.

  13. PENURUNAN WAKTU SET-UP UNTUK PENINGKATAN EFEKTIFITAS PADA PT. X

    Directory of Open Access Journals (Sweden)

    Hendri Hendri

    2015-06-01

    Full Text Available PT. X bergerak dalam industri manufuktur yang memproduksi komponen otomotif yang  salah satu prosesnya adalah pembuatan bearing. Saat ini, persaingan dalam dunia bisnis semakin ketat. Situasi ini membuat organisasi untuk memperbaiki diri dengan penurunan waktu set-up supaya dapat menghilangkan pemborosan sehingga peningkatan efektifitas dapat dicapai. Untuk melakukan penurunan waktu set-up dalam penelitian ini menggunakan metode Single Minute Exchange of Dies (SMED. SMED adalah salah satu metoda improvement dari Lean Manufacturing yang digunakan untuk mempercepat waktu yang dibutuhkan untuk melakukan setup pergantian dari memproduksi satu jenis produk ke model produk lainnya. Penelitian ini bertujuan untuk mengetahui waktu Set up, serta mengetahui cara memperbaiki dan menurunkan waktu set up. Setelah dilakukan penelitian diketahui total waktu set up atau change over serta dilakukan perbaikan pada tiga titik yakni memindakan enam aktivitas internal menjadi aktivitas eksernal yang aktivitasnya dipersingkat, mengganti cara kerja setting/pengencangan baut dari cara manual ke alat bantu pengencangan dengan bantuan tekanan udara (pneumatic, dan mengganti cara kerja setting/penyetelan manual menjadi penyetelan dengan mengunakan block gauge. Secara keseluruhan terjadi penurunan waktu set up yang signifikan. Dengan demikian terjadi peningkatan efektifitas dengan menghilangkan pemborosan waktu set up sehinga terjadi peningkatan jumlah produksi per jam.

  14. Exploring the Physics Limitations of Compact High Gradient Accelerating Structures Simulations of the Electron Current Spectrometer Setup in Geant4

    CERN Document Server

    Van Vliet, Philine Julia

    2017-01-01

    The high field gradient of 100 MV/m that will be applied to the accelerator cavities of the Compact Linear Collider (CLIC), gives rise to the problem of RF breakdowns. The field collapses and a plasma of electrons and ions is being formed in the cavity, preventing the RF field from penetrating the cavity. Electrons in the plasma are being accelerated and ejected out, resulting in a breakdown current up to a few Amp`eres, measured outside the cavities. These breakdowns lead to luminosity loss, so reducing their amount is of great importance. For this, a better understanding of the physics behind RF breakdowns is needed. To study these breakdowns, the XBox 2 test facility has a spectrometer setup installed after the RF cavity that is being conditioned. For this report, a simulation of this spectrometer setup has been made using Geant4. Once a detailed simulation of the RF field and cavity has been made, it can be connected to this simulation of the spectrometer setup and used to recreate the data that has b...

  15. Patterns of sexual recruitment of acroporid coral populations on the west fore reef at Discovery Bay, Jamaica.

    Science.gov (United States)

    Quinn, Norman J; Kojis, Barbara L

    2005-05-01

    Coral recruitment was examined on terracotta tiles deployed for four six-month periods between March 2001 and April 2003 on the West Fore Reef at Discovery Bay, Jamaica. During each sampling period, four tiles were deployed on each of two arrays at six depths ranging from 3 m to 33 m. Only three Acropora spat recruited to the tiles over the sampling period. The Acropora spat recruited during only one of the four six-month sampling periods and at only one depth, 3m. That represents a density of 8 spat m(-2) at 3 m depth for one six-month sampling period. Acropora recruitment represented Acropora colony (an A. palmata) was recorded during Point-Quarter surveys of coral cover and density at depths of 3 m, 9 m, 14 m and 19 m. Considering the paucity of acroporid colonies and the infrequent settlement of acroporid spat on the West Fore Reef, it is unlikely that the historic abundance of A. palmata and A. cervicornis will return soon.

  16. SU-F-P-23: Setup Uncertainties for the Lung Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Q; Vigneri, P; Madu, C; Potters, L [Northwell Health, New Hyde Park, NY (United States); Cao, Y; Jamshidi, A [Northwell Health, Lake Success, NY (United States); Klein, E [Long Island Jewish Medical Center, Lake Success, NY (United States)

    2016-06-15

    Purpose: The Exactrack X-ray system with six degree-of-freedom (6DoF) adjustment ability can be used for setup of lung stereotactic body radiation therapy. The setup uncertainties from ExacTrack 6D system were analyzed. Methods: The Exactrack X-ray 6D image guided radiotherapy system is used in our clinic. The system is an integration of 2 subsystems: (1): an infrared based optical position system and (2) a radiography kV x-ray imaging system. The infrared system monitors reflective body markers on the patient’s skin to assistant in the initial setup. The radiographic kV devices were used for patient positions verification and adjustment. The position verification was made by fusing the radiographs with the digitally reconstructed radiograph (DRR) images generated by simulation CT images using 6DoF fusion algorithms. Those results were recorded in our system. Gaussian functions were used to fit the data. Results: For 37 lung SBRT patients, the image registration results for the initial setup by using surface markers and for the verifications, were measured. The results were analyzed for 143 treatments. The mean values for the lateral, longitudinal, vertical directions were 0.1, 0.3 and 0.3mm, respectively. The standard deviations for the lateral, longitudinal and vertical directions were 0.62, 0.78 and 0.75mm respectively. The mean values for the rotations around lateral, longitudinal and vertical directions were 0.1, 0.2 and 0.4 degrees respectively, with standard deviations of 0.36, 0.34, and 0.42 degrees. Conclusion: The setup uncertainties for the lung SBRT cases by using Exactrack 6D system were analyzed. The standard deviations of the setup errors were within 1mm for all three directions, and the standard deviations for rotations were within 0.5 degree.

  17. SU-F-P-23: Setup Uncertainties for the Lung Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Zhang, Q; Vigneri, P; Madu, C; Potters, L; Cao, Y; Jamshidi, A; Klein, E

    2016-01-01

    Purpose: The Exactrack X-ray system with six degree-of-freedom (6DoF) adjustment ability can be used for setup of lung stereotactic body radiation therapy. The setup uncertainties from ExacTrack 6D system were analyzed. Methods: The Exactrack X-ray 6D image guided radiotherapy system is used in our clinic. The system is an integration of 2 subsystems: (1): an infrared based optical position system and (2) a radiography kV x-ray imaging system. The infrared system monitors reflective body markers on the patient’s skin to assistant in the initial setup. The radiographic kV devices were used for patient positions verification and adjustment. The position verification was made by fusing the radiographs with the digitally reconstructed radiograph (DRR) images generated by simulation CT images using 6DoF fusion algorithms. Those results were recorded in our system. Gaussian functions were used to fit the data. Results: For 37 lung SBRT patients, the image registration results for the initial setup by using surface markers and for the verifications, were measured. The results were analyzed for 143 treatments. The mean values for the lateral, longitudinal, vertical directions were 0.1, 0.3 and 0.3mm, respectively. The standard deviations for the lateral, longitudinal and vertical directions were 0.62, 0.78 and 0.75mm respectively. The mean values for the rotations around lateral, longitudinal and vertical directions were 0.1, 0.2 and 0.4 degrees respectively, with standard deviations of 0.36, 0.34, and 0.42 degrees. Conclusion: The setup uncertainties for the lung SBRT cases by using Exactrack 6D system were analyzed. The standard deviations of the setup errors were within 1mm for all three directions, and the standard deviations for rotations were within 0.5 degree.

  18. Technical note: An experimental set-up to measure latent and sensible heat fluxes from (artificial plant leaves

    Directory of Open Access Journals (Sweden)

    S. J. Schymanski

    2017-07-01

    Full Text Available Leaf transpiration and energy exchange are coupled processes that operate at small scales yet exert a significant influence on the terrestrial hydrological cycle and climate. Surprisingly, experimental capabilities required to quantify the energy–transpiration coupling at the leaf scale are lacking, challenging our ability to test basic questions of importance for resolving large-scale processes. The present study describes an experimental set-up for the simultaneous observation of transpiration rates and all leaf energy balance components under controlled conditions, using an insulated closed loop miniature wind tunnel and artificial leaves with pre-defined and constant diffusive conductance for water vapour. A range of tests documents the above capabilities of the experimental set-up and points to potential improvements. The tests reveal a conceptual flaw in the assumption that leaf temperature can be characterized by a single value, suggesting that even for thin, planar leaves, a temperature gradient between the irradiated and shaded or transpiring and non-transpiring leaf side can lead to bias when using observed leaf temperatures and fluxes to deduce effective conductances to sensible heat or water vapour transfer. However, comparison of experimental results with an explicit leaf energy balance model revealed only minor effects on simulated leaf energy exchange rates by the neglect of cross-sectional leaf temperature gradients, lending experimental support to our current understanding of leaf gas and energy exchange processes.

  19. Characterization of staphylococci in urban wastewater treatment plants in Spain, with detection of methicillin resistant Staphylococcus aureus ST398.

    Science.gov (United States)

    Gómez, Paula; Lozano, Carmen; Benito, Daniel; Estepa, Vanesa; Tenorio, Carmen; Zarazaga, Myriam; Torres, Carmen

    2016-05-01

    The objective of this study was to determine the prevalence of Staphylococcus in urban wastewater treatment plants (UWTP) of La Rioja (Spain), and to characterize de obtained isolates. 16 wastewater samples (8 influent, 8 effluent) of six UWTPs were seeded on mannitol-salt-agar and oxacillin-resistance-screening-agar-base for staphylococci and methicillin-resistant Staphylococcus aureus recovery. Antimicrobial susceptibility profile was determined for 16 antibiotics and the presence of 35 antimicrobial resistance genes and 14 virulence genes by PCR. S. aureus was typed by spa, agr, and multilocus-sequence-typing, and the presence of immune-evasion-genes cluster was analyzed. Staphylococcus spp. were detected in 13 of 16 tested wastewater samples (81%), although the number of CFU/mL decreased after treatment. 40 staphylococci were recovered (1-5/sample), and 8 of them were identified as S. aureus being typed as (number of strains): spa-t011/agr-II/ST398 (1), spa-t002/agr-II/ST5 (2), spa-t3262/agr-II/ST5 (1), spa-t605/agr-II/ST126 (3), and spa-t878/agr-III/ST2849 (1). S. aureus ST398 strain was methicillin-resistant and showed a multidrug resistance phenotype. Virulence genes tst, etd, sea, sec, seg, sei, sem, sen, seo, and seu, were detected among S. aureus and only ST5 strains showed genes of immune evasion cluster. Thirty-two coagulase-negative Staphylococcus of 12 different species were recovered (number of strains): Staphylococcus equorum (7), Staphylococcus vitulinus (4), Staphylococcus lentus (4), Staphylococcus sciuri (4), Staphylococcus fleurettii (2), Staphylococcus haemolyticus (2), Staphylococcus hominis (2), Staphylococcus saprophyticus (2), Staphylococcus succinus (2), Staphylococcus capitis (1), Staphylococcus cohnii (1), and Staphylococcus epidermidis (1). Five presented a multidrug resistance phenotype. The following resistance and virulence genes were found: mecA, lnu(A), vga(A), tet(K), erm(C), msr(A)/(B), mph(C), tst, and sem. We found that

  20. An evaluation of setup uncertainties for patients treated to pelvic sites

    International Nuclear Information System (INIS)

    Hunt, Margie A.; Schultheiss, Timothy E.; Desobry, Gregory E.; Hakki, Morgan; Hanks, Gerald E.

    1995-01-01

    Purpose: Successful delivery of conformal fields requires stringent immobilization and treatment verification, as well as knowledge of the setup reproducibility. The purpose of this study was to compare the three-dimensional distribution of setup variations for patients treated to pelvic sites with electronic portal imaging devices (EPID) and portal film. Methods and Materials: Nine patients with genitourinary and gynecological cancers immobilized with custom casts and treated with a four-field whole-pelvis technique were imaged daily using an EPID and filmed once every five to seven treatments. The three-dimensional translational and rotational setup errors were determined using a technique that relies on anatomical landmarks identified on simulation and treatment images. The distributions of the translational and rotational variations in each dimension as well as the total displacement of the treatment isocenter from the simulation isocenter were determined. Results: Grouped analysis of all patients revealed average unidirectional translational deviations of less than 2 mm and a standard deviation of 5.3 mm. The average total undirected distance between the treatment and simulated isocenters was 8.3 mm with a standard deviation of 5 mm. Individual patient analysis revealed eight of nine patients had statistically significant nonzero mean translational variations (p < 0.05). Translational variations measured with film were an average of 1.4 mm less than those measured with EPID, but this difference was not statistically significant. Conclusion: Translational variations measured in this study are in general agreement with previous studies. The use of the EPID in this study was less intrusive and may have resulted in less additional attention being given each imaging setup. This may explain the slightly larger average translational variations observed with EPID vs. film, and suggests that the use of EPIDs is a superior method for assessing the true extent of setup

  1. The experimental setup for studying the molecular composition of nanoscale films and coatings

    International Nuclear Information System (INIS)

    Turiev A M; Butkhuzi T G; Ramonova A G; Magkoev T T; Tsidaeva N I

    2011-01-01

    It is offered the method of measurement and design of the experimental setup, allowing to control the flow of particles from the surface of organic films during annealing by pulsed laser radiation. The method is based on the TOF(Time Of Flight) principle of detecting particles, desorbed from the surface by laser pulses, used for annealing. The principle of registration and the structure (block- scheme) of the experimental setup and its constituent parts are detailed in the work The setup consists of the analytical part, the system of laser irradiation and computer measurement system. The basis of the analytical part of the installation is a TOF(Time Of Flight) mass spectrometer of original construction.

  2. Design of experimental setup for supercritical CO2 jet under high ambient pressure conditions

    Science.gov (United States)

    Shi, Huaizhong; Li, Gensheng; He, Zhenguo; Wang, Haizhu; Zhang, Shikun

    2016-12-01

    With the commercial extraction of hydrocarbons in shale and tight reservoirs, efficient methods are needed to accelerate developing process. Supercritical CO2 (SC-CO2) jet has been considered as a potential way due to its unique fluid properties. In this article, a new setup is designed for laboratory experiment to research the SC-CO2 jet's characteristics in different jet temperatures, pressures, standoff distances, ambient pressures, etc. The setup is composed of five modules, including SC-CO2 generation system, pure SC-CO2 jet system, abrasive SC-CO2 jet system, CO2 recovery system, and data acquisition system. Now, a series of rock perforating (or case cutting) experiments have been successfully conducted using the setup about pure and abrasive SC-CO2 jet, and the results have proven the great perforating efficiency of SC-CO2 jet and the applications of this setup.

  3. Cone beam CT-based set-up strategies with and without rotational correction for stereotactic body radiation therapy in the liver.

    Science.gov (United States)

    Bertholet, Jenny; Worm, Esben; Høyer, Morten; Poulsen, Per

    2017-06-01

    Accurate patient positioning is crucial in stereotactic body radiation therapy (SBRT) due to a high dose regimen. Cone-beam computed tomography (CBCT) is often used for patient positioning based on radio-opaque markers. We compared six CBCT-based set-up strategies with or without rotational correction. Twenty-nine patients with three implanted markers received 3-6 fraction liver SBRT. The markers were delineated on the mid-ventilation phase of a 4D-planning-CT. One pretreatment CBCT was acquired per fraction. Set-up strategy 1 used only translational correction based on manual marker match between the CBCT and planning CT. Set-up strategy 2 used automatic 6 degrees-of-freedom registration of the vertebrae closest to the target. The 3D marker trajectories were also extracted from the projections and the mean position of each marker was calculated and used for set-up strategies 3-6. Translational correction only was used for strategy 3. Translational and rotational corrections were used for strategies 4-6 with the rotation being either vertebrae based (strategy 4), or marker based and constrained to ±3° (strategy 5) or unconstrained (strategy 6). The resulting set-up error was calculated as the 3D root-mean-square set-up error of the three markers. The set-up error of the spinal cord was calculated for all strategies. The bony anatomy set-up (2) had the largest set-up error (5.8 mm). The marker-based set-up with unconstrained rotations (6) had the smallest set-up error (0.8 mm) but the largest spinal cord set-up error (12.1 mm). The marker-based set-up with translational correction only (3) or with bony anatomy rotational correction (4) had equivalent set-up error (1.3 mm) but rotational correction reduced the spinal cord set-up error from 4.1 mm to 3.5 mm. Marker-based set-up was substantially better than bony-anatomy set-up. Rotational correction may improve the set-up, but further investigations are required to determine the optimal correction

  4. Design of a continuous process setup for precipitated calcium carbonate production from steel converter slag.

    Science.gov (United States)

    Mattila, Hannu-Petteri; Zevenhoven, Ron

    2014-03-01

    A mineral carbonation process "slag2PCC" for carbon capture, utilization, and storage is discussed. Ca is extracted from steel slag by an ammonium salt solvent and carbonated with gaseous CO2 after the separation of the residual slag. The solvent is reused after regeneration. The effects of slag properties such as the content of free lime, fractions of Ca, Si, Fe, and V, particle size, and slag storage on the Ca extraction efficiency are studied. Small particles with a high free-lime content and minor fractions of Si and V are the most suitable. To limit the amount of impurities in the process, the slag-to-liquid ratio should remain below a certain value, which depends on the slag composition. Also, the design of a continuous test setup (total volume ∼75 L) is described, which enables quick process variations needed to adapt the system to the varying slag quality. Different precipitated calcium carbonate crystals (calcite and vaterite) are generated in different parts of the setup. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Flap testing on the rotating test rig in the INDUFLAP project

    DEFF Research Database (Denmark)

    Barlas, Athanasios; Aagaard Madsen, Helge; Enevoldsen, Karen

    Tests of a prototype Controllable Rubber Trailing Edge Flap (CRTEF) are performed on the rotating test rig at the Risø campus of DTU. The general description and objectives are presented, along with an overview of sensors on the setup and the test cases. The post-processing of data is discussed...

  6. Tests of Local Hadron Calibration Approaches in ATLAS Combined Beam Tests

    International Nuclear Information System (INIS)

    Grahn, Karl-Johan; Kiryunin, Andrey; Pospelov, Guennadi

    2011-01-01

    Three ATLAS calorimeters in the region of the forward crack at |η| 3.2 in the nominal ATLAS setup and a typical section of the two barrel calorimeters at |η| = 0.45 of ATLAS have been exposed to combined beam tests with single electrons and pions. Detailed shower shape studies of electrons and pions with comparisons to various Geant4 based simulations utilizing different physics lists are presented for the endcap beam test. The local hadron calibration approach as used in the full Atlas setup has been applied to the endcap beam test data. An extension of it using layer correlations has been tested with the barrel test beam data. Both methods utilize modular correction steps based on shower shape variables to correct for invisible energy inside the reconstructed clusters in the calorimeters (compensation) and for lost energy deposits outside of the reconstructed clusters (dead material and out-of-cluster deposits). Results for both methods and comparisons to Monte Carlo simulations are presented.

  7. Comparison of computer workstation with film for detecting setup errors

    International Nuclear Information System (INIS)

    Fritsch, D.S.; Boxwala, A.A.; Raghavan, S.; Coffee, C.; Major, S.A.; Muller, K.E.; Chaney, E.L.

    1997-01-01

    Purpose/Objective: Workstations designed for portal image interpretation by radiation oncologists provide image displays and image processing and analysis tools that differ significantly compared with the standard clinical practice of inspecting portal films on a light box. An implied but unproved assumption associated with the clinical implementation of workstation technology is that patient care is improved, or at least not adversely affected. The purpose of this investigation was to conduct observer studies to test the hypothesis that radiation oncologists can detect setup errors using a workstation at least as accurately as when following standard clinical practice. Materials and Methods: A workstation, PortFolio, was designed for radiation oncologists to display and inspect digital portal images for setup errors. PortFolio includes tools to enhance images; align cross-hairs, field edges, and anatomic structures on reference and acquired images; measure distances and angles; and view registered images superimposed on one another. In a well designed and carefully controlled observer study, nine radiation oncologists, including attendings and residents, used PortFolio to detect setup errors in realistic digitally reconstructed portal (DRPR) images computed from the NLM visible human data using a previously described approach † . Compared with actual portal images where absolute truth is ill defined or unknown, the DRPRs contained known translation or rotation errors in the placement of the fields over target regions in the pelvis and head. Twenty DRPRs with randomly induced errors were computed for each site. The induced errors were constrained to a plane at the isocenter of the target volume and perpendicular to the central axis of the treatment beam. Images used in the study were also printed on film. Observers interpreted the film-based images using standard clinical practice. The images were reviewed in eight sessions. During each session five images were

  8. Visuo-acoustic stimulation that helps you to relax: A virtual reality setup for patients in the intensive care unit.

    Science.gov (United States)

    Gerber, Stephan M; Jeitziner, Marie-Madlen; Wyss, Patric; Chesham, Alvin; Urwyler, Prabitha; Müri, René M; Jakob, Stephan M; Nef, Tobias

    2017-10-16

    After prolonged stay in an intensive care unit (ICU) patients often complain about cognitive impairments that affect health-related quality of life after discharge. The aim of this proof-of-concept study was to test the feasibility and effects of controlled visual and acoustic stimulation in a virtual reality (VR) setup in the ICU. The VR setup consisted of a head-mounted display in combination with an eye tracker and sensors to assess vital signs. The stimulation consisted of videos featuring natural scenes and was tested in 37 healthy participants in the ICU. The VR stimulation led to a reduction of heart rate (p = 0. 049) and blood pressure (p = 0.044). Fixation/saccade ratio (p < 0.001) was increased when a visual target was presented superimposed on the videos (reduced search activity), reflecting enhanced visual processing. Overall, the VR stimulation had a relaxing effect as shown in vital markers of physical stress and participants explored less when attending the target. Our study indicates that VR stimulation in ICU settings is feasible and beneficial for critically ill patients.

  9. Radiated Emissions Test Approach

    Science.gov (United States)

    2015-10-02

    1. Draft Department of Transportation (DOT) Test Plan to Develop : Interference Tolerance Masks for GNSS Receivers in the L1 : Radiofrequency Band (1559 1610 MHz) provides high level : overview of radiated emissions test setup : 2. Presenta...

  10. Thermal neutron dose calculations in a brain phantom from 7Li(p,n) reaction based BNCT setup

    International Nuclear Information System (INIS)

    Elshahat, B.A.; Naqvi, A.A.; Maalej, N.; Abdallah, Khalid

    2006-01-01

    Monte Carlo simulations were carried out to calculate neutron dose in a brain phantom from a 7 Li(p,n) reaction based setup utilizing a high density polyethylene moderator with graphite reflector. The dimensions of the moderator and the reflector were optimized through optimization of epithermal /(fast +thermal) neutron intensity ratio as a function of geometric parameters of the setup. Results of our calculation showed the capability of our setup to treat the tumor within 4 cm of the head surface. The calculated Peak Therapeutic Ratio for the setup was found to be 2.15. With further improvement in the moderator design and brain phantom irradiation arrangement, the setup capabilities can be improved to reach further deep-seated tumor. (author)

  11. A compact multi-chamber setup for degradation and lifetime studies of organic solar cells

    DEFF Research Database (Denmark)

    Gevorgyan, Suren; Jørgensen, Mikkel; Krebs, Frederik C

    2011-01-01

    A controlled atmosphere setup designed for long-term degradation studies of organic solar cells under illumination is presented. The setup was designed with ease-of-use and compactness in mind and allows for multiple solar cells distributed on four glass substrates to be studied in four different...

  12. Characterization of a neutron imaging setup at the INES facility

    Science.gov (United States)

    Durisi, E. A.; Visca, L.; Albertin, F.; Brancaccio, R.; Corsi, J.; Dughera, G.; Ferrarese, W.; Giovagnoli, A.; Grassi, N.; Grazzi, F.; Lo Giudice, A.; Mila, G.; Nervo, M.; Pastrone, N.; Prino, F.; Ramello, L.; Re, A.; Romero, A.; Sacchi, R.; Salvemini, F.; Scherillo, A.; Staiano, A.

    2013-10-01

    The Italian Neutron Experimental Station (INES) located at the ISIS pulsed neutron source (Didcot, United Kingdom) provides a thermal neutron beam mainly used for diffraction analysis. A neutron transmission imaging system was also developed for beam monitoring and for aligning the sample under investigation. Although the time-of-flight neutron diffraction is a consolidated technique, the neutron imaging setup is not yet completely characterized and optimized. In this paper the performance for neutron radiography and tomography at INES of two scintillator screens read out by two different commercial CCD cameras is compared in terms of linearity, signal-to-noise ratio, effective dynamic range and spatial resolution. In addition, the results of neutron radiographies and a tomography of metal alloy test structures are presented to better characterize the INES imaging capabilities of metal artifacts in the cultural heritage field.

  13. Comparison of setup deviations for two thermoplastic immobilization masks in glottis cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jae Hong [Dept. of Biomedical Engineering, College of Medicine, The Catholic University, Seoul (Korea, Republic of)

    2017-03-15

    The purpose of this study was compare to the patient setup deviation of two different type thermoplastic immobilization masks for glottis cancer in the intensity-modulated radiation therapy (IMRT). A total of 16 glottis cancer cases were divided into two groups based on applied mask type: standard or alternative group. The mean error (M), three-dimensional setup displacement error (3D-error), systematic error (Σ), random error (σ) were calculated for each group, and also analyzed setup margin (mm). The 3D-errors were 5.2 ± 1.3 mm and 5.9 ± 0.7 mm for the standard and alternative groups, respectively; the alternative group was 13.6% higher than the standard group. The systematic errors in the roll angle and the x, y, z directions were 0.8°, 1.7 mm, 1.0 mm, and 1.5 mm in the alternative group and 0.8°, 1.1 mm, 1.8 mm, and 2.0 mm in the alternative group. The random errors in the x, y, z directions were 10.9%, 1.7%, and 23.1% lower in the alternative group than in the standard group. However, absolute rotational angle (i.e., roll) in the alternative group was 12.4% higher than in the standard group. For calculated setup margin, the alternative group in x direction was 31.8% lower than in standard group. In contrast, the y and z direction were 52.6% and 21.6% higher than in the standard group. Although using a modified thermoplastic immobilization mask could be affect patient setup deviation in terms of numerical results, various point of view for an immobilization masks has need to research in terms of clinic issue.

  14. Formula student suspension setup and laptime simulation tool

    NARCIS (Netherlands)

    van den Heuvel, E.; Besselink, I.J.M.; Nijmeijer, H.

    2013-01-01

    In motorsports time is usually limited. With use of dedicated tools for measuring wheel alignment, camber, ride heights etc. setting up the car can be done fast and consistent. With the setup sequence and tools described in this report, progress has been made in the time it takes to set up the car.

  15. Cone Beam Computed Tomography Guidance for Setup of Patients Receiving Accelerated Partial Breast Irradiation

    International Nuclear Information System (INIS)

    White, Elizabeth A.; Cho, John; Vallis, Katherine A.; Sharpe, Michael B.; Lee, Grace B.Sc.; Blackburn, Helen; Nageeti, Tahani; McGibney, Carol; Jaffray, David A.

    2007-01-01

    Purpose: To evaluate the role of cone-beam CT (CBCT) guidance for setup error reduction and soft tissue visualization in accelerated partial breast irradiation (APBI). Methods and Materials: Twenty patients were recruited for the delivery of radiotherapy to the postoperative cavity (3850 cGy in 10 fractions over 5 days) using an APBI technique. Cone-beam CT data sets were acquired after an initial skin-mark setup and before treatment delivery. These were registered online using the ipsilateral lung and external contours. Corrections were executed for translations exceeding 3 mm. The random and systematic errors associated with setup using skin-marks and setup using CBCT guidance were calculated and compared. Results: A total of 315 CBCT data sets were analyzed. The systematic errors for the skin-mark setup were 2.7, 1.7, and 2.4 mm in the right-left, anterior-posterior, and superior-inferior directions, respectively. These were reduced to 0.8, 0.7, and 0.8 mm when CBCT guidance was used. The random errors were reduced from 2.4, 2.2, and 2.9 mm for skin-marks to 1.5, 1.5, and 1.6 mm for CBCT guidance in the right-left, anterior-posterior, and superior-inferior directions, respectively. Conclusion: A skin-mark setup for APBI patients is sufficient for current planning target volume margins for the population of patients studied here. Online CBCT guidance minimizes the occurrence of large random deviations, which may have a greater impact for the accelerated fractionation schedule used in APBI. It is also likely to permit a reduction in planning target volume margins and provide skin-line visualization and dosimetric evaluation of cardiac and lung volumes

  16. External Quality Assessment for KRAS Testing Is Needed: Setup of a European Program and Report of the First Joined Regional Quality Assessment Rounds

    Science.gov (United States)

    Bellon, Ellen; Ligtenberg, Marjolijn J.L.; Tejpar, Sabine; Cox, Karen; de Hertogh, Gert; de Stricker, Karin; Edsjö, Anders; Gorgoulis, Vassilis; Höfler, Gerald; Jung, Andreas; Kotsinas, Athanassios; Laurent-Puig, Pierre; López-Ríos, Fernando; Hansen, Tine Plato; Rouleau, Etienne; Vandenberghe, Peter; van Krieken, Johan J.M.

    2011-01-01

    The use of epidermal growth factor receptor–targeting antibodies in metastatic colorectal cancer has been restricted to patients with wild-type KRAS tumors by the European Medicines Agency since 2008, based on data showing a lack of efficacy and potential harm in patients with mutant KRAS tumors. In an effort to ensure optimal, uniform, and reliable community-based KRAS testing throughout Europe, a KRAS external quality assessment (EQA) scheme was set up. The first large assessment round included 59 laboratories from eight different European countries. For each country, one regional scheme organizer prepared and distributed the samples for the participants of their own country. The samples included unstained sections of 10 invasive colorectal carcinomas with known KRAS mutation status. The samples were centrally validated by one of two reference laboratories. The laboratories were allowed to use their own preferred method for histological evaluation, DNA isolation, and mutation analysis. In this study, we analyze the setup of the KRAS scheme. We analyzed the advantages and disadvantages of the regional scheme organization by analyzing the outcome of genotyping results, analysis of tumor percentage, and written reports. We conclude that only 70% of laboratories correctly identified the KRAS mutational status in all samples. Both the false-positive and false-negative results observed negatively affect patient care. Reports of the KRAS test results often lacked essential information. We aim to further expand this program to more laboratories to provide a robust estimate of the quality of KRAS testing in Europe, and provide the basis for remedial measures and harmonization. PMID:21441573

  17. A method for patient set-up guidance in radiotherapy using augmented reality

    International Nuclear Information System (INIS)

    Talbot, J.; Meyer, J.; Watts, R.; Grasset, R.

    2009-01-01

    Full text: A system for patient set-up in external beam radiotherapy was developed using Augmented Reality (AR). Live images of the linac treatment couch and patient were obtained with video cameras and displayed on a nearby monitor. A 3D model of the patient's external contour was obtained from planning CT data, and AR tracking software was used to superimpose the model onto the video images in the correct position for treatment. Throughout set-up and treatment, the user can view the monitor and visually confirm that the patient is positioned correctly. To ensure that the virtual contour was displayed in the correct position, a process was devised to register the coordinates of the linac with the camera images. A cube with AR tracking markers attached to its faces was constructed for alignment with the isocentre using room lasers or cone-beam CT. The performance of the system was investigated in a clinical environment by using it to position an anthropomorphic phantom without the aid of additional set-up methods. The positioning errors were determined by means of CBCT and image registration. The translational set-up errors were found to be less than 2.4 mm and the rotational errors less than 0.3 0 . This proof-of-principle study has demonstrated the feasibility of using AR for patient position and pose guidance.

  18. GRAPhEME: a setup to measure (n, xn γ) reaction cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Henning, Greg; Bacquias, A.; Capdevielle, O.; Dessagne, P.; Kerveno, M.; Rudolf, G. [Universite de Strasbourg, IPHC, 23 rue du Loess 67037 Strasbourg (France); CNRS, UMR7178, 67037 Strasbourg (France); Borcea, C.; Negret, A.; Olacel, A. [Nat. Inst. Of Phys. And Nucl. Eng., Bucharest (Romania); Drohe, J.C.; Plompen, A.J.M.; Nyman, M. [EU/ JRC-IRMM, Geel (Belgium)

    2015-07-01

    Most of nuclear reactor developments are using evaluated data base for numerical simulations. However, the considered databases present still large uncertainties and disagreements. To improve their level of precision, new measurements are needed, in particular for (n, xn) reactions, which are of great importance as they modify the neutron spectrum, the neutron population, and produce radioactive species. The IPHC group started an experimental program to measure (n, xn gamma) reaction cross sections using prompt gamma spectroscopy and neutron energy determination by time of flight. Measurements of (n, xn gamma) cross section have been performed for {sup 235,238}U, {sup 232}Th, {sup nat,182,183,184,186}W, {sup nat}Zr. The experimental setup is installed at the neutron beam at GELINA (Geel, Belgium). The setup has recently been upgraded with the addition of a highly segmented 36 pixels planar HPGe detector. Significant efforts have been made to reduce radiation background and electromagnetic perturbations. The setup is equipped with a high rate digital acquisition system. The analysis of the segmented detector data requires a specific procedure to account for cross signals between pixels. An overall attention is paid to the precision of the measurement. The setup characteristic and the analysis procedure will be presented along with the acquisition and analysis challenges. Examples of results and their impact on models will be discussed. (authors)

  19. A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom

    Directory of Open Access Journals (Sweden)

    Payam Samadi Miandoab

    2016-12-01

    Full Text Available Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion of dynamic organs, a phantom employs non-uniform rational B-splines (NURBS-based Cardiac-Torso method with spline-based model to generate 4D computed tomography (CT images. First, to generate all the possible roto-translation positions, the 4D CT images were imported to Medical Image Data Examiner (AMIDE. Then, for automatic, real time verification of geometrical setup, an artificial neural network (ANN was proposed to estimate patient displacement, using training sets. Moreover, three external motion markers were synchronized with a patient couch position as reference points. In addition, the technique was validated through simulated activities by using reference 4D CT data acquired from five patients. Results The results indicated that patient geometrical set-up is highly depended on the comprehensiveness of training set. By using ANN model, the average patient setup error in XCAT phantom was reduced from 17.26 mm to 0.50 mm. In addition, in the five real patients, these average errors were decreased from 18.26 mm to 1.48 mm various breathing phases ranging from inhalation to exhalation were taken into account for patient setup. Uncertainty error assessment and different setup errors were obtained from each respiration phase. Conclusion This study proposed a new method for alignment of patient setup error using ANN model. Additionally, our correlation model (ANN could estimate true patient position with less error.

  20. Crosstalk in an FDM Laboratory Setup and the Athena X-IFU End-to-End Simulator

    Science.gov (United States)

    den Hartog, R.; Kirsch, C.; de Vries, C.; Akamatsu, H.; Dauser, T.; Peille, P.; Cucchetti, E.; Jackson, B.; Bandler, S.; Smith, S.; Wilms, J.

    2018-04-01

    The impact of various crosstalk mechanisms on the performance of the Athena X-IFU instrument has been assessed with detailed end-to-end simulations. For the crosstalk in the electrical circuit, a detailed model has been developed. In this contribution, we test this model against measurements made with an FDM laboratory setup and discuss the assumption of deterministic crosstalk in the context of the weak link effect in the detectors. We conclude that crosstalk levels predicted by the model are conservative with respect to the observed levels.

  1. Mathematical model of the electronuclear set-up on the beam of the JINR synchrotron

    International Nuclear Information System (INIS)

    Barashenkov, V.S.; Kumawat, H.; Lobanova, V.A.; Kumar, V.

    2003-01-01

    On the base of the Monte Carlo code CASCADE, developed at JINR, a mathematical model of the deep-subcritical set-up with uranium blanket used in experiments underway at JINR using a 0.6-4 GeV proton beam, is created. The neutron spectra, yields and energies of generated particles are calculated and compared for several modifications of the set-up. The influence of paraffin and graphite moderators on the characteristics of particles escaping lead target is studied. The modelled set-up can be considered as a first step to experiments with the designed at JINR U-Pu ADS SAD with heat power of several tens of kW

  2. Mathematical Model of the Electronuclear Set-Up on the Beam of the JINR Synchrotron

    CERN Document Server

    Barashenkov, V S; Kumawat, H; Lobanova, V A

    2004-01-01

    On the base of the Monte Carlo code CASCADE, developed at JINR, a mathematical model of the deep-subcritical set-up with uranium blanket used in experiments underway at JINR using a 0.6-4 GeV proton beam, is created. The neutron spectra, yields and energies of generated particles are calculated and compared for several modifications of the set-up. The influence of paraffin and graphite moderators on the characteristics of particles escaping lead target is studied. The modelled set-up can be considered as a first step to experiments with the designed at JINR U-Pu ADS SAD with heat power of several tens of kW.

  3. Tools and setups for experiments with AC and rotating magnetic fields

    International Nuclear Information System (INIS)

    Ponikvar, D

    2010-01-01

    A rotating magnetic field is the basis for the transformation of electrical energy to mechanical energy. School experiments on the rotating magnetic field are rare since they require the use of specially prepared mechanical setups and/or relatively large, three-phase power supplies to achieve strong magnetic fields. This paper proposes several experiments and describes setups and tools which are easy to obtain and work with. Free software is offered to generate the required signals by a personal computer. The experiments can be implemented in introductory physics courses on electromagnetism for undergraduates or specialized courses at high schools.

  4. Cone beam CT with zonal filters for simultaneous dose reduction, improved target contrast and automated set-up in radiotherapy

    International Nuclear Information System (INIS)

    Moore, C J; Marchant, T E; Amer, A M

    2006-01-01

    Cone beam CT (CBCT) using a zonal filter is introduced. The aims are reduced concomitant imaging dose to the patient, simultaneous control of body scatter for improved image quality in the tumour target zone and preserved set-up detail for radiotherapy. Aluminium transmission diaphragms added to the CBCT x-ray tube of the Elekta Synergy TM linear accelerator produced an unattenuated beam for a central 'target zone' and a partially attenuated beam for an outer 'set-up zone'. Imaging doses and contrast noise ratios (CNR) were measured in a test phantom for transmission diaphragms 12 and 24 mm thick, for 5 and 10 cm long target zones. The effect on automatic registration of zonal CBCT to conventional CT was assessed relative to full-field and lead-collimated images of an anthropomorphic phantom. Doses along the axis of rotation were reduced by up to 50% in both target and set-up zones, and weighted dose (two thirds surface dose plus one third central dose) was reduced by 10-20% for a 10 cm long target zone. CNR increased by up to 15% in zonally filtered CBCT images compared to full-field images. Automatic image registration remained as robust as that with full-field images and was superior to CBCT coned down using lead-collimation. Zonal CBCT significantly reduces imaging dose and is expected to benefit radiotherapy through improved target contrast, required to assess target coverage, and wide-field edge detail, needed for robust automatic measurement of patient set-up error

  5. Development of a Simple Positron Age-Momentum Setup

    Science.gov (United States)

    Sheffield, Thomas; Quarles, C. A.

    2009-04-01

    A positron age-momentum setup that uses NIM Bin electronic modules and a conventional multichannel analyzer (MCA) is described. The essential idea is to accumulate a Doppler broadened spectrum (sensitive to the annihilation electron momentum) using a high purity Germanium detector in coincidence with a BaF2 scintillation counter, which also serves as the stop signal in a conventional positron lifetime setup. The MCA that collects the Doppler spectrum is gated by a selected region of the lifetime spectrum. Thus we can obtain Doppler broadening spectra as a function of positron lifetime: an age-momentum spectrum. The apparatus has been used so far to investigate a ZnO sample where the size of different vacancy trapping sites may affect the positron lifetime and the Doppler broadening spectrum. We are also looking at polymer and rubber carbon-black composite samples where differences in the Doppler spectrum may arise from positron trapping or positronium formation in the samples. Correction for background and contribution from the positron source itself to the Doppler spectrum will be discussed.

  6. Automatic Generation of Setup for CNC Spring Coiler Based on Case-based Reasoning

    Institute of Scientific and Technical Information of China (English)

    KU Xiangchen; WANG Runxiao; LI Jishun; WANG Dongbo

    2006-01-01

    When producing special-shape spring in CNC spring coiler, the setup of the coiler is often a manual work using a trial-and-error method. As a result, the setup of coiler consumes so much time and becomes the bottleneck of the spring production process. In order to cope with this situation, this paper proposes an automatic generation system of setup for CNC spring coiler using case-based reasoning (CBR). The core of the study contains: (1) integrated reasoning model of CBR system;(2) spatial shape describe of special-shape spring based on feature;(3) coiling case representation using shape feature matrix; and (4) case similarity measure algorithm. The automatic generation system has implemented with C++ Builder 6.0 and is helpful in improving the automaticity and efficiency of spring coiler.

  7. Cryogenic setup for trapped ion quantum computing.

    Science.gov (United States)

    Brandl, M F; van Mourik, M W; Postler, L; Nolf, A; Lakhmanskiy, K; Paiva, R R; Möller, S; Daniilidis, N; Häffner, H; Kaushal, V; Ruster, T; Warschburger, C; Kaufmann, H; Poschinger, U G; Schmidt-Kaler, F; Schindler, P; Monz, T; Blatt, R

    2016-11-01

    We report on the design of a cryogenic setup for trapped ion quantum computing containing a segmented surface electrode trap. The heat shield of our cryostat is designed to attenuate alternating magnetic field noise, resulting in 120 dB reduction of 50 Hz noise along the magnetic field axis. We combine this efficient magnetic shielding with high optical access required for single ion addressing as well as for efficient state detection by placing two lenses each with numerical aperture 0.23 inside the inner heat shield. The cryostat design incorporates vibration isolation to avoid decoherence of optical qubits due to the motion of the cryostat. We measure vibrations of the cryostat of less than ±20 nm over 2 s. In addition to the cryogenic apparatus, we describe the setup required for an operation with 40 Ca + and 88 Sr + ions. The instability of the laser manipulating the optical qubits in 40 Ca + is characterized by yielding a minimum of its Allan deviation of 2.4 ⋅ 10 -15 at 0.33 s. To evaluate the performance of the apparatus, we trapped 40 Ca + ions, obtaining a heating rate of 2.14(16) phonons/s and a Gaussian decay of the Ramsey contrast with a 1/e-time of 18.2(8) ms.

  8. Patient set-up verification by infrared optical localization and body surface sensing in breast radiation therapy

    International Nuclear Information System (INIS)

    Spadea, Maria Francesca; Baroni, Guido; Riboldi, Marco; Orecchia, Roberto; Pedotti, Antonio; Tagaste, Barbara; Garibaldi, Cristina

    2006-01-01

    Background and purpose: The aim of the study was to investigate the clinical application of a technique for patient set-up verification in breast cancer radiotherapy, based on the 3D localization of a hybrid configuration of surface control points. Materials and methods: An infrared optical tracker provided the 3D position of two passive markers and 10 laser spots placed around and within the irradiation field on nine patients. A fast iterative constrained minimization procedure was applied to detect and compensate patient set-up errors, through the control points registration with reference data coming from treatment plan (markers reference position, CT-based surface model). Results: The application of the corrective spatial transformation estimated by the registration procedure led to significant improvement of patient set-up. Median value of 3D errors affecting three additional verification markers within the irradiation field decreased from 5.7 to 3.5 mm. Errors variability (25-75%) decreased from 3.2 to 2.1 mm. Laser spots registration on the reference surface model was documented to contribute substantially to set-up errors compensation. Conclusions: Patient set-up verification through a hybrid set of control points and constrained surface minimization algorithm was confirmed to be feasible in clinical practice and to provide valuable information for the improvement of the quality of patient set-up, with minimal requirement of operator-dependant procedures. The technique combines conveniently the advantages of passive markers based methods and surface registration techniques, by featuring immediate and robust estimation of the set-up accuracy from a redundant dataset

  9. MO-FG-CAMPUS-JeP3-02: A Novel Setup Approach to Improve C-Spine Curvature Reproducibility for Head and Neck Radiotherapy Using Optical Surface Imaging with Two Regions of Interest

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, K; Gil, M; Li, G [Memorial Sloan Kettering Cancer Center, New York, NY (United States); Della Biancia, C [Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: To develop a novel approach to improve cervical spine (c-spine) curvature reproducibility for head and neck (HN) patients using optical surface imaging (OSI) with two regions of interests (ROIs). Methods: The OSI-guided, two-step setup procedure requires two ROIs: ROI-1 of the shoulders and ROI-2 of the face. The neck can be stretched or squeezed in superior-inferior (SI) direction using a specially-designed sliding head support. We hypothesize that when these two ROIs are aligned, the c-spine should fall into a naturally reproducible position under same setup conditions. An anthropomorphous phantom test was performed to examine neck pitch angles comparing with the calculated angles. Three volunteers participated in the experiments, which start with conventional HN setup using skin markers and room lasers. An OSI image and lateral photo-picture were acquired as the references. In each of the three replicate tests, conventional setup was first applied after volunteers got on the couch. ROI-1 was aligned by moving the body, followed by ROI-2 alignment via adjusting head position and orientation under real-time OSI guidance. A final static OSI image and lateral picture were taken to evaluate both anterior and posterior surface alignments. Three degrees of freedom can be adjusted if an open-face mask was applied, including head SI shift using the sliding head support and pitch-and-roll rotations using a commercial couch extension. Surface alignment was analyzed comparing with conventional setup. Results: The neck pitch angle measured by OSI is consistent with the calculated (0.2±0.6°). Volunteer study illustrated improved c-spine setup reproducibility using OSI comparing with conventional setup. ROI alignments with 2mm/1° tolerance are achieved within 3 minutes. Identical knee support is important to achieve ROI-1 pitch alignment. Conclusion: The feasibility of this novel approach has been demonstrated for c-spine curvature setup reproducibility. Further

  10. JANUS - A setup for low-energy Coulomb excitation at ReA3

    Science.gov (United States)

    Lunderberg, E.; Belarge, J.; Bender, P. C.; Bucher, B.; Cline, D.; Elman, B.; Gade, A.; Liddick, S. N.; Longfellow, B.; Prokop, C.; Weisshaar, D.; Wu, C. Y.

    2018-03-01

    A new experimental setup for low-energy Coulomb excitation experiments was constructed in a collaboration between the National Superconducting Cyclotron Laboratory (NSCL), Lawrence Livermore National Laboratory (LLNL), and the University of Rochester and was commissioned at the general purpose beam line of NSCL's ReA3 reaccelerator facility. The so-called JANUS setup combines γ-ray detection with the Segmented Ge Array (SeGA) and scattered particle detection using a pair of segmented double-sided Si detectors (Bambino 2). The low-energy Coulomb excitation program that JANUS enables will complement intermediate-energy Coulomb excitation studies that have long been performed at NSCL by providing access to observables that quantify collectivity beyond the first excited state, including the sign and magnitude of excited-state quadrupole moments. In this work, the setup and its performance will be described based on the commissioning run that used stable 78Kr impinging onto a 1.09 mg/cm2208Pb target at a beam energy of 3.9 MeV/u.

  11. Pros and cons of characterising an optical translocation setup

    CSIR Research Space (South Africa)

    Maphanga, Charles

    2017-02-01

    Full Text Available an optical translocation setup Charles Maphanga 1, 2 , Rudzani Malabi 1, 2 , Saturnin Ombinda-Lemboumba 1 , Malik Maaza 2 , Patience Mthunzi-Kufa 1, 2* 1 Council for Scientific and Industrial Research, National Laser Centre, P O BOX 395, Pretoria...

  12. 60 GHz antenna measurement setup using a VNA without external frequency conversion

    DEFF Research Database (Denmark)

    Popa, Paula Irina; Pivnenko, Sergey; Nielsen, Jeppe Majlund

    2014-01-01

    an alternative solution which makes use of a standard wideband VNA without external frequency conversion units. The operational capability of the Planar Near-Field (PNF) Antenna Measurement Facility at the Technical University of Denmark was recently extended to 60 GHz employing an Agilent E8361A VNA (up to 67...... GHz). The upgrade involved procurement of very few additional components: two cables operational up to 65 GHz and an openended waveguide probe for tests in U-band (40-60 GHz). The first tests have shown good performance of the PNF setup: 50-60 dB dynamic range and small thermal drift in magnitude...... and phase, 0.06 dB and 6 degrees peak-to-peak deviations over 4 hours. A PNF measurement of a 25 dBi Standard Gain Horn was carried out and the results were compared to those from the DTU-ESA Spherical Near-Field Facility with a good agreement in the validity region. Uncertainty investigations regarding...

  13. Impact of different setup approaches in image-guided radiotherapy as primary treatment for prostate cancer. A study of 2940 setup deviations in 980 MVCTs

    Energy Technology Data Exchange (ETDEWEB)

    Schiller, Kilian; Specht, Hanno; Kampfer, Severin; Duma, Marciana Nona [Technische Universitaet Muenchen Klinikum rechts der Isar, Department of Radiation Oncology, Muenchen (Germany); Petrucci, Alessia [University of Florence, Department of Radiation Oncology, Florence (Italy); Geinitz, Hans [Krankenhaus der Barmherzigen Schwestern Linz, Department of Radiation Oncology, Linz (Austria); Schuster, Tibor [Klinikum Rechts der Isar, Technische Universitaet Muenchen, Institute for Medical Statistics and Epidemiology, Muenchen (Germany)

    2014-08-15

    The goal of this study was to assess the impact of different setup approaches in image-guided radiotherapy (IMRT) of the prostatic gland. In all, 28 patients with prostate cancer were enrolled in this study. After the placement of an endorectal balloon, the planning target volume (PTV) was treated to a dose of 70 Gy in 35 fractions. A simultaneously integrated boost (SIB) of 76 Gy (2.17 Gy per fraction and per day) was delivered to a smaller target volume. All patients underwent daily prostate-aligned IGRT by megavoltage CT (MVCT). Retrospectively, three different setup approaches were evaluated by comparison to the prostate alignment: setup by skin alignment, endorectal balloon alignment, and automatic registration by bones. A total of 2,940 setup deviations were analyzed in 980 fractions. Compared to prostate alignment, skin mark alignment was associated with substantial displacements, which were ≥ 8 mm in 13 %, 5 %, and 44 % of all fractions in the lateral, longitudinal, and vertical directions, respectively. Endorectal balloon alignment yielded displacements ≥ 8 mm in 3 %, 19 %, and 1 % of all setups; and ≥ 3 mm in 27 %, 58 %, and 18 % of all fractions, respectively. For bone matching, the values were 1 %, 1 %, and 2 % and 3 %, 11 %, and 34 %, respectively. For prostate radiotherapy, setup by skin marks alone is inappropriate for patient positioning due to the fact that, during almost half of the fractions, parts of the prostate would not be targeted successfully with an 8-mm safety margin. Bone matching performs better but not sufficiently for safety margins ≤ 3 mm. Endorectal balloon matching can be combined with bone alignment to increase accuracy in the vertical direction when prostate-based setup is not available. Daily prostate alignment remains the gold standard for high-precision radiotherapy with small safety margins. (orig.) [German] Das Ziel dieser Studie bestand darin, den Einfluss verschiedener Herangehensweisen bei der Einstellung einer

  14. Implementation of random set-up errors in Monte Carlo calculated dynamic IMRT treatment plans

    International Nuclear Information System (INIS)

    Stapleton, S; Zavgorodni, S; Popescu, I A; Beckham, W A

    2005-01-01

    The fluence-convolution method for incorporating random set-up errors (RSE) into the Monte Carlo treatment planning dose calculations was previously proposed by Beckham et al, and it was validated for open field radiotherapy treatments. This study confirms the applicability of the fluence-convolution method for dynamic intensity modulated radiotherapy (IMRT) dose calculations and evaluates the impact of set-up uncertainties on a clinical IMRT dose distribution. BEAMnrc and DOSXYZnrc codes were used for Monte Carlo calculations. A sliding window IMRT delivery was simulated using a dynamic multi-leaf collimator (DMLC) transport model developed by Keall et al. The dose distributions were benchmarked for dynamic IMRT fields using extended dose range (EDR) film, accumulating the dose from 16 subsequent fractions shifted randomly. Agreement of calculated and measured relative dose values was well within statistical uncertainty. A clinical seven field sliding window IMRT head and neck treatment was then simulated and the effects of random set-up errors (standard deviation of 2 mm) were evaluated. The dose-volume histograms calculated in the PTV with and without corrections for RSE showed only small differences indicating a reduction of the volume of high dose region due to set-up errors. As well, it showed that adequate coverage of the PTV was maintained when RSE was incorporated. Slice-by-slice comparison of the dose distributions revealed differences of up to 5.6%. The incorporation of set-up errors altered the position of the hot spot in the plan. This work demonstrated validity of implementation of the fluence-convolution method to dynamic IMRT Monte Carlo dose calculations. It also showed that accounting for the set-up errors could be essential for correct identification of the value and position of the hot spot

  15. Implementation of random set-up errors in Monte Carlo calculated dynamic IMRT treatment plans

    Science.gov (United States)

    Stapleton, S.; Zavgorodni, S.; Popescu, I. A.; Beckham, W. A.

    2005-02-01

    The fluence-convolution method for incorporating random set-up errors (RSE) into the Monte Carlo treatment planning dose calculations was previously proposed by Beckham et al, and it was validated for open field radiotherapy treatments. This study confirms the applicability of the fluence-convolution method for dynamic intensity modulated radiotherapy (IMRT) dose calculations and evaluates the impact of set-up uncertainties on a clinical IMRT dose distribution. BEAMnrc and DOSXYZnrc codes were used for Monte Carlo calculations. A sliding window IMRT delivery was simulated using a dynamic multi-leaf collimator (DMLC) transport model developed by Keall et al. The dose distributions were benchmarked for dynamic IMRT fields using extended dose range (EDR) film, accumulating the dose from 16 subsequent fractions shifted randomly. Agreement of calculated and measured relative dose values was well within statistical uncertainty. A clinical seven field sliding window IMRT head and neck treatment was then simulated and the effects of random set-up errors (standard deviation of 2 mm) were evaluated. The dose-volume histograms calculated in the PTV with and without corrections for RSE showed only small differences indicating a reduction of the volume of high dose region due to set-up errors. As well, it showed that adequate coverage of the PTV was maintained when RSE was incorporated. Slice-by-slice comparison of the dose distributions revealed differences of up to 5.6%. The incorporation of set-up errors altered the position of the hot spot in the plan. This work demonstrated validity of implementation of the fluence-convolution method to dynamic IMRT Monte Carlo dose calculations. It also showed that accounting for the set-up errors could be essential for correct identification of the value and position of the hot spot.

  16. MO-G-BRE-03: Automated Continuous Monitoring of Patient Setup with Second-Check Independent Image Registration

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, X; Fox, T; Schreibmann, E [Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA (United States)

    2014-06-15

    Purpose: To create a non-supervised quality assurance program to monitor image-based patient setup. The system acts a secondary check by independently computing shifts and rotations and interfaces with Varian's database to verify therapist's work and warn against sub-optimal setups. Methods: Temporary digitally-reconstructed radiographs (DRRs) and OBI radiographic image files created by Varian's treatment console during patient setup are intercepted and used as input in an independent registration module customized for accuracy that determines the optimal rotations and shifts. To deal with the poor quality of OBI images, a histogram equalization of the live images to the DDR counterparts is performed as a pre-processing step. A search for the most sensitive metric was performed by plotting search spaces subject to various translations and convergence analysis was applied to ensure the optimizer finds the global minima. Final system configuration uses the NCC metric with 150 histogram bins and a one plus one optimizer running for 2000 iterations with customized scales for translations and rotations in a multi-stage optimization setup that first corrects and translations and subsequently rotations. Results: The system was installed clinically to monitor and provide almost real-time feedback on patient positioning. On a 2 month-basis uncorrected pitch values were of a mean 0.016° with standard deviation of 1.692°, and couch rotations of − 0.090°± 1.547°. The couch shifts were −0.157°±0.466° cm for the vertical, 0.045°±0.286 laterally and 0.084°± 0.501° longitudinally. Uncorrected pitch angles were the most common source of discrepancies. Large variations in the pitch angles were correlated with patient motion inside the mask. Conclusion: A system for automated quality assurance of therapist's registration was designed and tested in clinical practice. The approach complements the clinical software's automated registration in

  17. MO-G-BRE-03: Automated Continuous Monitoring of Patient Setup with Second-Check Independent Image Registration

    International Nuclear Information System (INIS)

    Jiang, X; Fox, T; Schreibmann, E

    2014-01-01

    Purpose: To create a non-supervised quality assurance program to monitor image-based patient setup. The system acts a secondary check by independently computing shifts and rotations and interfaces with Varian's database to verify therapist's work and warn against sub-optimal setups. Methods: Temporary digitally-reconstructed radiographs (DRRs) and OBI radiographic image files created by Varian's treatment console during patient setup are intercepted and used as input in an independent registration module customized for accuracy that determines the optimal rotations and shifts. To deal with the poor quality of OBI images, a histogram equalization of the live images to the DDR counterparts is performed as a pre-processing step. A search for the most sensitive metric was performed by plotting search spaces subject to various translations and convergence analysis was applied to ensure the optimizer finds the global minima. Final system configuration uses the NCC metric with 150 histogram bins and a one plus one optimizer running for 2000 iterations with customized scales for translations and rotations in a multi-stage optimization setup that first corrects and translations and subsequently rotations. Results: The system was installed clinically to monitor and provide almost real-time feedback on patient positioning. On a 2 month-basis uncorrected pitch values were of a mean 0.016° with standard deviation of 1.692°, and couch rotations of − 0.090°± 1.547°. The couch shifts were −0.157°±0.466° cm for the vertical, 0.045°±0.286 laterally and 0.084°± 0.501° longitudinally. Uncorrected pitch angles were the most common source of discrepancies. Large variations in the pitch angles were correlated with patient motion inside the mask. Conclusion: A system for automated quality assurance of therapist's registration was designed and tested in clinical practice. The approach complements the clinical software's automated registration in

  18. Numerical study of a confocal ultrasonic setup for creation of cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Lafond, Maxime, E-mail: maxime.lafond@inserm.fr; Chavrier, Françoise; Prieur, Fabrice [Inserm, U1032, LabTau, Lyon, F-69003 (France); Université de Lyon, Lyon, F-69003 (France); Université Lyon 1, Lyon, F-69003 (France); Mestas, Jean-Louis; Lafon, Cyril [Inserm, U1032, LabTau, Lyon, F-69003 (France); Université de Lyon, Lyon, F-69003 (France); Université Lyon 1, Lyon, F-69003 (France); Caviskills SAS, Vaulx-En-Velin, F-69120 (France)

    2015-10-28

    Acoustic cavitation is used for various therapeutic applications such as local enhancement of drug delivery, histotripsy or hyperthermia. One of the utmost important parameter for cavitation creation is the rarefaction pressure. The typical magnitude of the rarefaction pressure required to initiate cavitation from gas dissolved in tissue is beyond the range of the megapascal. Because nonlinear effects need to be taken into account, a numerical simulator based on the Westervelt equation was used to study the pressure waveform and the acoustic field generated by a setup for creation of cavitation consisting of two high intensity focused ultrasound transducers mounted confocally. At constant acoustic power, simulations with only one and both transducers from the confocal setup showed that the distortion of the pressure waveform due to the combined effects of nonlinearity and diffraction is less pronounced when both confocal transducers are used. Consequently, the confocal setup generates a greater peak negative pressure at focus which is more favorable for cavitation initiation. Comparison between the confocal setup and a single transducer with the same total emitting surface puts in evidence the role of the spatial separation of the two beams. Furthermore, it has been previously shown that the location of the peak negative pressure created by a single transducer shifts from focus towards the transducers in the presence of nonlinear effects. The simulator was used to study a configuration where the acoustical axes of transducers intersect on the peak negative pressure instead of the geometrical focus. For a representative confocal setup, namely moderate nonlinear effects, a 2% increase of the peak negative pressure and 8% decrease of the peak positive pressure resulted from this configuration. These differences tend to increase by increasing nonlinear effects. Although the optimal position of the transducers varies with the nonlinear regimen, the intersection point

  19. Safety aspects of the FMPP (Fuel Manufacturing Pilot Plant) setup constructed by INVAP in the Arabic Republic of Egypt

    International Nuclear Information System (INIS)

    Cinat, Enrique; Boero, Norma L.

    1999-01-01

    The FMPP is a fuel plates manufacturing plant for test reactors. This facility was designed, constructed in El Cairo and turned-key handled by INVAP SE to the Arabian Republic of Egypt. In this project, CNEA participated in the transference of technology, elaboration of documents, training of Egyptian personnel and technical services during the setup of the facility in El Cairo. These tasks were undertaken by UPMP (Uranium Powder Manufacturing Plant) and ECRI (Research Reactors Fuel Elements Plant) personnel. Both plants in CNEA served as a FMPP design basis. During the setup of the facility a fuel element with natural uranium was firstly manufactured and then another one using uranium with 20% enrichment. In this paper the responses of the system regarding safety, after finishing the first two stages of manufacturing, are analyzed and evaluated. (author)

  20. Trace elements in human, cattle and swine teeth, measured by external beam PIXE-PIGE setup

    International Nuclear Information System (INIS)

    Tabacniks, M.H.; Rizzutto, M.A.; Added, N.; Liguori Neto, R.; Acquadro, J.C.; Vilela, M.; Oliveira, T.R.C.F.; Markarian, R.A.; Mori, M.

    2001-01-01

    The use of animal teeth to replace human teeth in dentistry school classes and to test chemicals and fillings, motivated for a better characterization of the elementary composition of their enamel, since some of the chemical properties, adhesion and chemical compatibility may depend on these parameters. Cattle, swine and human teeth were collected by dentists of the University of Sao Paulo. These teeth came primarily from Sao Paulo region and were analyzed for trace elements at the Open Nuclear Physics Laboratory, using a high energy external proton beam, PIXE-PIGE setup

  1. Beam test of Cherenkov counter prototype for ZDF setup

    International Nuclear Information System (INIS)

    Kacharava, A.K.; Macharashvili, G.G.; Nioradze, M.S.; Komarov, V.I.; Sopov, V.S.; Chernyshev, V.P.

    1995-01-01

    We describe a Cherenkov counter of total internal reflection for particle separation in the momentum range where all types of particles radiate Cherenkov light. The Cherenkov counter prototype with the lucite radiator was tested on the secondary beam of the ITEP (Moscow) accelerator. Dependence of the photomultiplier pulse height on the particle entrance angle was clearly observed. 4 refs., 4 figs

  2. SU-F-T-519: Is Geometry Based Setup Sufficient for All of the Head and Neck Treatment Cases?: A Feasibility Study Towards the Dose Based Setup

    International Nuclear Information System (INIS)

    Lee, S; Chen, S; Zhang, B; Xu, H; Prado, K; D’Souza, W; Yi, B

    2016-01-01

    Purpose: This study compares the geometric-based setup (GBS) which is currently used in the clinic to a novel concept of dose-based setup (DBS) of head and neck (H&N) patients using cone beam CT (CBCT) of the day; and evaluates the clinical advantages. Methods: Ten H&N patients who underwent re-simulation and re-plan due to noticeable anatomic changes during the course of the treatments were retrospectively reviewed on dosimetric changes in the assumption of no plan modification was performed. RayStation planning system (RaySearch Laboratories AB, Sweden) was used to match (ROI fusion module) between prescribed isodoseline (IDL) in the CBCT imported along with ROIs from re-planned CT and the IDL of original plan (Dose-based setup: DBS). Then, the CBCT plan based on daily setup using the GBS (previously used for a patient) and the DBS CBCT plan recalculated in RayStation compared against the original CT-sim plan. Results: Most of patients’ tumor coverage and OAR doses got generally worsen when the CBCT plans were compared with original CT-sim plan with GBS. However, when DBS intervened, the OAR dose and tumor coverage was better than the GBS. For example, one of patients’ daily average doses of right parotid and oral cavity increased to 26% and 36%, respectively from the original plan to the GBS planning. However, it only increased by 13% and 24%, respectively with DBS. GTV D95 coverage also decreased by 16% with GBS, but only 2% decreased with DBS. Conclusion: DBS method is superior to GBS to prevent any abrupt dose changes to OARs as well as PTV/CTV or GTV at least for some H&N cases. Since it is not known when the DBS is beneficial to the GBS, a system which enables the on-line DBS may be helpful for better treatment of H&N.

  3. SU-F-T-519: Is Geometry Based Setup Sufficient for All of the Head and Neck Treatment Cases?: A Feasibility Study Towards the Dose Based Setup

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S; Chen, S; Zhang, B; Xu, H; Prado, K; D’Souza, W; Yi, B [University of Maryland School of Medicine, Baltimore, MD (United States)

    2016-06-15

    Purpose: This study compares the geometric-based setup (GBS) which is currently used in the clinic to a novel concept of dose-based setup (DBS) of head and neck (H&N) patients using cone beam CT (CBCT) of the day; and evaluates the clinical advantages. Methods: Ten H&N patients who underwent re-simulation and re-plan due to noticeable anatomic changes during the course of the treatments were retrospectively reviewed on dosimetric changes in the assumption of no plan modification was performed. RayStation planning system (RaySearch Laboratories AB, Sweden) was used to match (ROI fusion module) between prescribed isodoseline (IDL) in the CBCT imported along with ROIs from re-planned CT and the IDL of original plan (Dose-based setup: DBS). Then, the CBCT plan based on daily setup using the GBS (previously used for a patient) and the DBS CBCT plan recalculated in RayStation compared against the original CT-sim plan. Results: Most of patients’ tumor coverage and OAR doses got generally worsen when the CBCT plans were compared with original CT-sim plan with GBS. However, when DBS intervened, the OAR dose and tumor coverage was better than the GBS. For example, one of patients’ daily average doses of right parotid and oral cavity increased to 26% and 36%, respectively from the original plan to the GBS planning. However, it only increased by 13% and 24%, respectively with DBS. GTV D95 coverage also decreased by 16% with GBS, but only 2% decreased with DBS. Conclusion: DBS method is superior to GBS to prevent any abrupt dose changes to OARs as well as PTV/CTV or GTV at least for some H&N cases. Since it is not known when the DBS is beneficial to the GBS, a system which enables the on-line DBS may be helpful for better treatment of H&N.

  4. Control system for RF-driven negative ion source experimental setup at HUST

    Energy Technology Data Exchange (ETDEWEB)

    Li, Dong; Wang, Xiaomin, E-mail: xm_wang@hust.edu.cn; Zhao, Peng; Liu, Kaifeng; Zhang, Lige; Yue, Haikun; Chen, Dezhi; Zuo, Chen

    2017-03-15

    Highlights: • The CompactRIO system is reliable and could achieve high-speed data collection. • The queue and event software structure allows the control code to be flexible. • TCP/IP performs better than shared variable method for mass data transmission. • The method for lowering the peak RF reflected power has been discussed and given. - Abstract: An experimental setup of RF-driven negative ion source has been built at the Huazhong University of Science and Technology (HUST). The control system for this setup is responsible for RF loading, gas feeding, filament heating, filament DC bias, data collection and Langmuir probe triggering during plasma production. To research influences on the plasma ignition of gas puff and RF power loading, the control system should be of flexible operating sequence, high-speed data collection and reliable data transmission. The general control unit (GCU) adopts a CompactRIO system, which performs high-speed data collection for gas pressure and RF power. The host control program adopts a queue and event structure for flexible operation, and TCP/IP method is applied for mass data transmission. The development of the host control program is described in detail. The test results of the shared variable and TCP/IP methods are presented, as well as data showing the advantages of the TCP/IP method. The experiment results with two different sequences of plasma production are given and discussed here.

  5. Four point bending setup for characterization of semiconductor piezoresistance

    DEFF Research Database (Denmark)

    Richter, Jacob; Arnoldus, Morten Berg; Hansen, Ole

    2008-01-01

    bending fixture is manufactured in polyetheretherketon and a dedicated silicon chip with embedded piezoresistors fits in the fixture. The fixture is actuated by a microstepper actuator and a high sensitivity force sensor measures the applied force on the fixture and chip. The setup includes heaters...

  6. Design of a compact high-energy setup for x-ray phase-contrast imaging

    Science.gov (United States)

    Schüttler, Markus; Yaroshenko, Andre; Bech, Martin; Potdevin, Guillaume; Malecki, Andreas; Chabior, Michael; Wolf, Johannes; Tapfer, Arne; Meiser, Jan; Kunka, Danays; Amberger, Maximilian; Mohr, Jürgen; Pfeiffer, Franz

    2014-03-01

    The main shortcoming of conventional biomedical x-ray imaging is the weak soft-tissue contrast caused by the small differences in the absorption coefficients between different materials. This issue can be addressed by x-ray phasesensitive imaging approaches, e.g. x-ray Talbot-Lau grating interferometry. The advantage of the three-grating Talbot-Lau approach is that it allows to acquire x-ray phase-contrast and dark-field images with a conventional lab source. However, through the introduction of the grating interferometer some constraints are imposed on the setup geometry. In general, the grating pitch and the mean x-ray energy determine the setup dimensions. The minimal length of the setup increases linearly with energy and is proportional to p2, where p is the grating pitch. Thus, a high-energy (100 keV) compact grating-based setup for x-ray imaging can be realized only if gratings with aspect-ratio of approximately 300 and a pitch of 1-2 μm were available. However, production challenges limit the availability of such gratings. In this study we consider the use of non-binary phase-gratings as means of designing a more compact grating interferometer for phase-contrast imaging. We present simulation and experimental data for both monochromatic and polychromatic case. The results reveal that phase-gratings with triangular-shaped structures yield visibilities that can be used for imaging purposes at significantly shorter distances than binary gratings. This opens the possibility to design a high-energy compact setup for x-ray phase-contrast imaging. Furthermore, we discuss different techniques to achieve triangular-shaped phase-shifting structures.

  7. Phase measuring deflectometry. An improved setup for measuring CTA mirror facets

    Energy Technology Data Exchange (ETDEWEB)

    Specovius, Andreas; Eldik, Christopher van; Woernlein, Andre; Ziegler, Alexander [Erlangen Centre for Astroparticle Physics (ECAP) (Germany)

    2016-07-01

    The future Cherenkov Telescope Array (CTA) will consist of up to 100 single telescopes with a total reflecting surface of ∝10.000 m{sup 2} made of numerous mirror facets. Characterizing the surface properties of these facets is quite challenging concerning time and logistics. An efficient way to reliably reconstruct the surface of specular free-forms is Phase Measuring Deflectometry (PMD). PMD is routinely used to characterize the focal distance and point spread function of spherical CTA prototype mirrors. To address the possibility to measure the surface properties of aspherical mirrors, a new PMD setup has recently been built. First experience with this setup is reported.

  8. Test of rotating wheel system for measuring correlated α-decay

    International Nuclear Information System (INIS)

    Wu Xiaolei; Gan Zaiguo; Guo Junsheng; Fan Hongmei; Qin Zhi

    2005-01-01

    A rotating-wheel set-up used for measuring and studying the heavy nuclei with α-decay was built. This system was tested experimentally by using ion-beam from SFC. The test results prove that this set-up was useful and reliable. It provides simple and effective equipment and technique to synthesize and identify new nuclides of Z=107 in the near future. (authors)

  9. Testing Backbone.js

    CERN Document Server

    Roemer, Ryan

    2013-01-01

    This book is packed with the step by step tutorial and instructions in recipe format helping you setup test infrastructure and gradually advance your skills to plan, develop, and test your backbone applications.If you are a JavaScript developer looking for recipes to create and implement test support for your backbone application, then this book is ideal for you.

  10. The preliminary study of setup errors' impact on dose distribution of image guide radiation therapy for head and neck cancer

    International Nuclear Information System (INIS)

    Xu Luying; Pan Jianji; Wang Xiaoliang; Bai Penggang; Li Qixin; Fei Zhaodong; Chen Chuanben; Ma Liqin; Tang Tianlan

    2011-01-01

    Objective: To measure the set-up errors of patients with head and neck (H and N) cancer during the image guided intensity-modulated radiotherapy (IMRT) treatment and analyze the impact of setup errors on dose distribution; then to further investigate the necessity of adjustment online for H and N cancer during IMRT treatment. Methods: Cone-beam CT (CBCT) scanning of thirty patients with H and N cancer were acquired by once weekly with a total of 6 times during IMRT treatment. The CBCT images and the original planning CT images were matched by the bony structure and worked out the translational errors of the x, y, z axis, as well as rotational errors. The dose distributions were recalculated based on the data of each setup error. The dose of planning target volume (PTV) and organs at risk were calculated in the re-planning, and than compared with the original plan by paired t-test. Results: The mean value of x, y, z axis translational set-up errors were (1.06 ± 0.95)mm, (0.95 ± 0.77)mm and (1.31 ± 1.07)mm, respectively. The rotational error of x, y, z axis were (1.04 ±0.791), (1.06 ±0.89) and (0.81 ±0.61 ), respectively. PTV 95% volume dose (D 95 ) and PTV minimal dose of re-planning for 6 times set-up were lower than original plan (6526.6 cGy : 6630.3 cGy, t =3.98, P =0.000 and 5632.6 cGy : 5792.5 cGy, t =- 2.89, P =0.007). Brain stem received 45 Gydose volume (V 45 ) and 1% brain stem volume dose (D 01 )were higher than original plan (3.54% : 2.75%, t =3.84, P =0.001 and 5129.7 cGy : 4919.3 cGy, t =4.36, P =0.000). Conclusions: The set-up errors led to the dose of PTV D 95 obviously insufficient and significantly increased V 45 , D 01 of the brainstem. So, adjustment online is necessary for H and N cancer during IMRT treatment. (authors)

  11. IBM PC based automatic drive system for Bulat setup

    International Nuclear Information System (INIS)

    Luchaninov, A.A.; Tolok, V.T.

    1999-01-01

    Non-expensive computer drive system for Bulat setup is described. System's hardware consists of IBM PC and conjunction block, providing 12 output channels, Software includes the main program, utilities and technology processes database. System may be used at surface modification processes, especially multilayer multicomponent coatings deposition

  12. Impacts of wave-induced circulation in the surf zone on wave setup

    Science.gov (United States)

    Guérin, Thomas; Bertin, Xavier; Coulombier, Thibault; de Bakker, Anouk

    2018-03-01

    Wave setup corresponds to the increase in mean water level along the coast associated with the breaking of short-waves and is of key importance for coastal dynamics, as it contributes to storm surges and the generation of undertows. Although overall well explained by the divergence of the momentum flux associated with short waves in the surf zone, several studies reported substantial underestimations along the coastline. This paper investigates the impacts of the wave-induced circulation that takes place in the surf zone on wave setup, based on the analysis of 3D modelling results. A 3D phase-averaged modelling system using a vortex force formalism is applied to hindcast an unpublished field experiment, carried out at a dissipative beach under moderate to very energetic wave conditions (Hm 0 = 6m at breaking and Tp = 22s). When using an adaptive wave breaking parameterisation based on the beach slope, model predictions for water levels, short waves and undertows improved by about 30%, with errors reducing to 0.10 m, 0.10 m and 0.09 m/s, respectively. The analysis of model results suggests a very limited impact of the vertical circulation on wave setup at this dissipative beach. When extending this analysis to idealized simulations for different beach slopes ranging from 0.01 to 0.05, it shows that the contribution of the vertical circulation (horizontal and vertical advection and vertical viscosity terms) becomes more and more relevant as the beach slope increases. In contrast, for a given beach slope, the wave height at the breaking point has a limited impact on the relative contribution of the vertical circulation on the wave setup. For a slope of 0.05, the contribution of the terms associated with the vertical circulation accounts for up to 17% (i.e. a 20% increase) of the total setup at the shoreline, which provides a new explanation for the underestimations reported in previously published studies.

  13. Experimental Setup For Study of Drop Deformation In Air Flow

    Directory of Open Access Journals (Sweden)

    Basalaev Sergey

    2017-01-01

    Full Text Available Experimental study for study of deformation of drops in air flow is considered. Experimental setup includes a module for obtaining the drops, an air flow system and measuring system. Module for formation of drops is in the form of vertically arranged dropper with capillary with the possibility of formation of fixed drops. Air flow supply system comprises an air pump coupled conduit through a regulating valve with a cylindrical pipe, installed coaxially with dropper. The measuring system includes the video camera located with possibility of visualization of drop and the Pitot gage for measurement of flow rate of air located in the output section of branch pipe. This experimental setup allows to provide reliable and informative results of the investigation of deformation of drops in the air flow.

  14. Test setup for long term reliability investigation of Silicon Carbide MOSFETs

    DEFF Research Database (Denmark)

    Baker, Nick; Munk-Nielsen, Stig; Beczkowski, Szymon

    2013-01-01

    Silicon Carbide MOSFETs are now widely available and have frequently been demonstrated to offer numerous advantages over Silicon based devices. However, reliability issues remain a significant concern in their realisation in commercial power electronic systems. In this paper, a test bench...... is designed that enables an accelerated power cycling test to be performed on packaged Silicon Carbide MOSFETs (TO-247) under realistic operating conditions. An accelerated power cycling test is then performed, with on-state resistance selected as the observed parameter to detect degradation. On......-state resistance is routinely monitored online through the use of an innovative voltage measurement system. The packaged Silicon Carbide MOSFET is shown to exhibit a 25% increase in on-state resistance as the device ages throughout its lifetime, with the test still on-going....

  15. SU-E-T-463: Quantification of Rotational Variation in Mouse Setup for IGRT

    Energy Technology Data Exchange (ETDEWEB)

    McCarroll, R; Rubinstein, A; Kingsley, C; Yang, J; Yang, P; Court, L [UT MD Anderson Cancer Center, Houston, TX (United States)

    2014-06-01

    Purpose: New small-animal irradiators include extremely precise IGRT capabilities. However, mouse immobilization and localization remains a challenge. In particular, unlike week-to-week translational displacements, rotational changes in positioning are not easily corrected for in subject setup. Using two methods of setup, we aim to quantify week-to-week rotational variation in mice for the purpose of IGRT planning in small animal studies. Methods: Ten mice were imaged weekly using breath-hold CBCT (X-RAD 225 Cx), with the mouse positioned in a half-pipe support, providing 40 scans. A second group of two mice were positioned in a 3D printed immobilization device, which was created using a CT from a similarly shaped mouse, providing 10 scans. For each mouse, the first image was taken to be the reference image. Subsequent CT images were then rigidly registered, based on bony anatomy. Rotations in the axial (roll), sagittal (pitch), and coronal (yaw) planes were recorded and used to quantify variation in angular setup. Results: For the mice imaged in the half pipe, average magnitude of roll was found to be 5.4±4.6° (range: −12.9:18.86°), of pitch 1.6±1.3° (range: −1.4:4.7°), and of yaw 1.9±1.5° (range −5.4:1.1°). For the mice imaged in the printed setup; average magnitude of roll was found to be 0.64±0.6° (range: −2.1:1.0°), of pitch 0.6±0.4° (range: 0.0:1.3°), and of yaw 0.2±0.1° (range: 0.0:0.4°). The printed setup provided reduction in roll, pitch, and yaw by 88, 62, and 90 percent, respectively. Conclusion: For the typical setup routine, roll in mouse position is the dominant source of rotational variation. However, when a printed device was used, drastic improvements in mouse immobilization were seen. This work provides a promising foundation for mouse immobilization, required for full scale small animal IGRT. Currently, we are making improvements to allo±w the use of a similar system for MR, PET, and bioluminescence.

  16. A novel Brain Computer Interface for classification of social joint attention in autism and comparison of 3 experimental setups: A feasibility study.

    Science.gov (United States)

    Amaral, Carlos P; Simões, Marco A; Mouga, Susana; Andrade, João; Castelo-Branco, Miguel

    2017-10-01

    We present a novel virtual-reality P300-based Brain Computer Interface (BCI) paradigm using social cues to direct the focus of attention. We combined interactive immersive virtual-reality (VR) technology with the properties of P300 signals in a training tool which can be used in social attention disorders such as autism spectrum disorder (ASD). We tested the novel social attention training paradigm (P300-based BCI paradigm for rehabilitation of joint-attention skills) in 13 healthy participants, in 3 EEG systems. The more suitable setup was tested online with 4 ASD subjects. Statistical accuracy was assessed based on the detection of P300, using spatial filtering and a Naïve-Bayes classifier. We compared: 1 - g.Mobilab+ (active dry-electrodes, wireless transmission); 2 - g.Nautilus (active electrodes, wireless transmission); 3 - V-Amp with actiCAP Xpress dry-electrodes. Significant statistical classification was achieved in all systems. g.Nautilus proved to be the best performing system in terms of accuracy in the detection of P300, preparation time, speed and reported comfort. Proof of concept tests in ASD participants proved that this setup is feasible for training joint attention skills in ASD. This work provides a unique combination of 'easy-to-use' BCI systems with new technologies such as VR to train joint-attention skills in autism. Our P300 BCI paradigm is feasible for future Phase I/II clinical trials to train joint-attention skills, with successful classification within few trials, online in ASD participants. The g.Nautilus system is the best performing one to use with the developed BCI setup. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Trace element analysis in an optimized set-up for total reflection PIXE (TPIXE)

    International Nuclear Information System (INIS)

    Van Kan, J.A.; Vis, R.D.

    1996-01-01

    A newly constructed chamber for measuring with MeV proton beams at small incidence angles (0 to 35 mrad) is used to analyse trace elements on flat surfaces such as Si wafers, quartz substrates and perspex. This set-up is constructed in such a way that the X-ray detector can reach very large solid angles, larger than 1 sr. Using these large solid angles in combination with the reduction of bremsstrahlungs background, lower limits of detection (LOD) using TPIXE can be obtained as compared with PIXE in the conventional geometry. Standard solutions are used to determine the LODs obtainable with TPIXE in the optimized set-up. These solutions contain traces of As and Sr with concentrations down to 20 ppb in an insulin solution. The limits of detection found are compared with earlier ones obtained with TPIXE in a non optimized set-up and with TXRF results. (author)

  18. A dual centre study of setup accuracy for thoracic patients based on Cone-Beam CT data

    DEFF Research Database (Denmark)

    Nielsen, Tine B; Hansen, Vibeke N; Westberg, Jonas

    2011-01-01

    BACKGROUND AND PURPOSE: To compare setup uncertainties at two different institutions by using identical imaging and analysis techniques for thoracic patients with different fixation equipments. METHODS AND MATERIALS: Patient registration results from Cone-Beam CT (CBCT) scans of 174 patients were...... increase of the systematic setup uncertainties in between imaging fractions. A margin reduction of ⩾0.2cm can be achieved for patients with peak-to-peak respiration amplitudes of ⩾1.2cm when changing from 4D-CT to Active Breathing Coordinator™ (ABC). CONCLUSIONS: The setup uncertainties at the two...

  19. Setup errors and effectiveness of Optical Laser 3D Surface imaging system (Sentinel) in postoperative radiotherapy of breast cancer.

    Science.gov (United States)

    Wei, Xiaobo; Liu, Mengjiao; Ding, Yun; Li, Qilin; Cheng, Changhai; Zong, Xian; Yin, Wenming; Chen, Jie; Gu, Wendong

    2018-05-08

    Breast-conserving surgery (BCS) plus postoperative radiotherapy has become the standard treatment for early-stage breast cancer. The aim of this study was to compare the setup accuracy of optical surface imaging by the Sentinel system with cone-beam computerized tomography (CBCT) imaging currently used in our clinic for patients received BCS. Two optical surface scans were acquired before and immediately after couch movement correction. The correlation between the setup errors as determined by the initial optical surface scan and CBCT was analyzed. The deviation of the second optical surface scan from the reference planning CT was considered an estimate for the residual errors for the new method for patient setup correction. The consequences in terms for necessary planning target volume (PTV) margins for treatment sessions without setup correction applied. We analyzed 145 scans in 27 patients treated for early stage breast cancer. The setup errors of skin marker based patient alignment by optical surface scan and CBCT were correlated, and the residual setup errors as determined by the optical surface scan after couch movement correction were reduced. Optical surface imaging provides a convenient method for improving the setup accuracy for breast cancer patient without unnecessary imaging dose.

  20. Setup of Galvanic Sensors for the Monitoring of Gilded Bronzes

    Directory of Open Access Journals (Sweden)

    Sara Goidanich

    2014-04-01

    Full Text Available Traditional electrochemical techniques, such as linear polarization resistance (Rp, and electrochemical impedance spectroscopy (EIS, cannot be applied to gilded bronzes, as it may not be possible to interpret the results obtained due to the bimetallic nature of the studied material. The measurement of the macrocouple current generated by the gold/bronze galvanic couple can be used as an indicator of degradation processes. Nevertheless, this measurement cannot be performed directly on the original artifacts due to the systematic presence of short-circuits between the two metals. In the present work the use of galvanic sensors is proposed as a possible solution for the monitoring of gilded bronze artefacts. The sensors have been designed to simulate real gilded bronze surfaces in terms of composition and stratigraphy and have proved to be a reliable diagnostic tool for the in situ monitoring of the rates of deterioration of gilded bronze surfaces and to test new conservation treatments. Their set-up and application is reported and their performances discussed.

  1. Design of excitation signals for active system monitoring in a performance assessment setup

    DEFF Research Database (Denmark)

    Green, Torben; Izadi-Zamanabadi, Roozbeh; Niemann, Hans Henrik

    2011-01-01

    This paper investigates how the excitation signal should be chosen for a active performance setup. The signal is used in a setup where the main purpose is to detect whether a parameter change of the controller has changed the global performance significantly. The signal has to be able to excite...... the dynamics of the subsystem under investigation both before and after the parameter change. The controller is well know, but there exists no detailed knowledge about the dynamics of the subsystem....

  2. Impact of setup variability on incidental lung irradiation during tangential breast treatment

    International Nuclear Information System (INIS)

    Carter, D.C.; Marks, L.B.; Bentel, G.B.

    1995-01-01

    Purpose: 1) To determine the variability in treatment setup during a 5 week course of tangential breast treatment. 2) To assess the relationship between the height of the lung shadow at the central axis (Central Lung Distance: CLD) on the tangential port film and the percent of total lung volume included within the tangential fields (to verify the previously reported result from Bornstein, et al, IJROBP 18:181, 90). 3) To determine the impact of the variabilities in treatment setup on the volume of lung that is incidentally included within the radiation fields. Methods: 1) 172 port films of tangential breast/chest wall fields were reviewed from 20 patients who received tangential beam treatment for breast cancer. All patients were immobilized in customized hemibody foam cradles during simulation and treatment. The CLD (height of the lung shadow at the central axis) seen on each of the port films was compared to the corresponding simulator film (correcting for differences in magnification) as an assessment of setup variability. Both inter and intrapatient differences were considered. 2) A three-dimensional dose calculation (reflecting lung density) was performed, and the percent of total lung volume within the field was compared to the CLD. 3) The three-dimensional dose calculation was repeated for selected patients with the location of the treatment beams modified to reflect typical setup variations, in order to assess the impact of this variability on the volume of lung irradiated. Results: 1) The CLD measured on the port films was within 3 mm of that prescribed on the simulator film in 43% ((74(172))) of the port films. The variation was 3-5 mm in 26 %, 5-10 mm in 25 % and > 10 mm in 6 %. The data are shown in Figure 1. 2) There was an excellent correlation found between the height of the lung shadow and the percent of total lung volume seen within the radiation field, (Figure 2), thus verifying the concept previously reported by Bornstein. 3) A 1 cm setup

  3. A photovoltaic module diagnostic setup for lock-in-thermography and lock-in electroluminescence imaging

    DEFF Research Database (Denmark)

    Parikh, Harsh; Spataru, Sergiu; Sera, Dezso

    2018-01-01

    Electroluminescence (EL) imaging and infrared (IRT) thermography techniques have become indispensable tools in recent years for health diagnostic of PV modules in solar industry application. Complementary to these imaging methods, lock-in techniques can effectively remove noise by periodically...... modulating the input signal and averaging it over a desired number of periods. We propose a combined lock-in EL and lock-in IRT diagnostic setup for accurate analysis of different types of faults occurring in a solar module. The setup is built around a Goldeye CL-033 high-speed SWIR camera, which can acquire...... experimental work on a (36/72) cell solar module using combined (EL) or (IRT) lock-in-thermography. The setup allows one to investigate the different technological problems that can occur when performing PV diagnostics in drone-based inspections....

  4. Automatic detection of patient identification and positioning errors in radiation therapy treatment using 3-dimensional setup images.

    Science.gov (United States)

    Jani, Shyam S; Low, Daniel A; Lamb, James M

    2015-01-01

    To develop an automated system that detects patient identification and positioning errors between 3-dimensional computed tomography (CT) and kilovoltage CT planning images. Planning kilovoltage CT images were collected for head and neck (H&N), pelvis, and spine treatments with corresponding 3-dimensional cone beam CT and megavoltage CT setup images from TrueBeam and TomoTherapy units, respectively. Patient identification errors were simulated by registering setup and planning images from different patients. For positioning errors, setup and planning images were misaligned by 1 to 5 cm in the 6 anatomical directions for H&N and pelvis patients. Spinal misalignments were simulated by misaligning to adjacent vertebral bodies. Image pairs were assessed using commonly used image similarity metrics as well as custom-designed metrics. Linear discriminant analysis classification models were trained and tested on the imaging datasets, and misclassification error (MCE), sensitivity, and specificity parameters were estimated using 10-fold cross-validation. For patient identification, our workflow produced MCE estimates of 0.66%, 1.67%, and 0% for H&N, pelvis, and spine TomoTherapy images, respectively. Sensitivity and specificity ranged from 97.5% to 100%. MCEs of 3.5%, 2.3%, and 2.1% were obtained for TrueBeam images of the above sites, respectively, with sensitivity and specificity estimates between 95.4% and 97.7%. MCEs for 1-cm H&N/pelvis misalignments were 1.3%/5.1% and 9.1%/8.6% for TomoTherapy and TrueBeam images, respectively. Two-centimeter MCE estimates were 0.4%/1.6% and 3.1/3.2%, respectively. MCEs for vertebral body misalignments were 4.8% and 3.6% for TomoTherapy and TrueBeam images, respectively. Patient identification and gross misalignment errors can be robustly and automatically detected using 3-dimensional setup images of different energies across 3 commonly treated anatomical sites. Copyright © 2015 American Society for Radiation Oncology. Published by

  5. MATLAB simulation for an experimental setup of digital feedback control

    International Nuclear Information System (INIS)

    Zheng Lifang; Liu Songqiang

    2005-01-01

    This paper describes the digital feedback simulation using MATLAB for an experimental accelerator control setup. By analyzing the plant characteristic in time-domain and frequency-domain, a guideline for design of digital filter and PID controller is derived. (authors)

  6. Sample to moderator volume ratio effects in neutron yield from a PGNAA setup

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia)]. E-mail: aanaqvi@kfupm.edu.sa; Fazal-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia); Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia); Khateeb-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia)

    2007-02-15

    Performance of a prompt gamma ray neutron activation analysis (PGNAA) setup depends upon thermal neutron yield at the PGNAA sample location. For a moderator, which encloses a sample, thermal neutron intensity depends upon the effective moderator volume excluding the void volume due to sample volume. A rectangular moderator assembly has been designed for the King Fahd University of Petroleum and Minerals (KFUPM) PGNAA setup. The thermal and fast neutron yield has been measured inside the sample cavity as a function of its front moderator thickness using alpha particle tracks density and recoil proton track density inside the CR-39 nuclear track detectors (NTDs). The thermal/fast neutron yield ratio, obtained from the alpha particle tracks density to proton tracks density ratio in the NTDs, shows an inverse correlation with sample to moderator volume ratio. Comparison of the present results with the previously published results of smaller moderators of the KFUPM PGNAA setup confirms the observation.

  7. A merged-beam setup at SOLEIL dedicated to photoelectron–photoion coincidence studies on ionic species

    Energy Technology Data Exchange (ETDEWEB)

    Bizau, J.M., E-mail: jean-marc.bizau@u-psud.fr [Institut des Sciences Moléculaires d’Orsay (ISMO), CNRS, Univ. Paris Paris-Sud, Université Paris-Saclay, F-91405 Orsay (France); Synchrotron SOLEIL, L’Orme des Merisiers, Saint-Aubin, BP 48, F-91192 Gif-sur-Yvette Cedex (France); Cubaynes, D. [Institut des Sciences Moléculaires d’Orsay (ISMO), CNRS, Univ. Paris Paris-Sud, Université Paris-Saclay, F-91405 Orsay (France); Synchrotron SOLEIL, L’Orme des Merisiers, Saint-Aubin, BP 48, F-91192 Gif-sur-Yvette Cedex (France); Guilbaud, S.; El Eassan, N.; Al Shorman, M.M.; Bouisset, E.; Guigand, J.; Moustier, O.; Marié, A.; Nadal, E. [Institut des Sciences Moléculaires d’Orsay (ISMO), CNRS, Univ. Paris Paris-Sud, Université Paris-Saclay, F-91405 Orsay (France); Robert, E.; Nicolas, C. [Synchrotron SOLEIL, L’Orme des Merisiers, Saint-Aubin, BP 48, F-91192 Gif-sur-Yvette Cedex (France); Miron, C. [Synchrotron SOLEIL, L’Orme des Merisiers, Saint-Aubin, BP 48, F-91192 Gif-sur-Yvette Cedex (France); Extreme Light Infrastructure—Nuclear Physics, “Horia Hulubei” National Institute for Physics and Nuclear Engineering, 30 Reactorului Street, RO-077125 Măgurele, Jud. Ilfov (Romania)

    2016-07-15

    Highlights: • Description of a merged-beam setup at SOLEIL synchrotron radiation facility. • Unique setup of this kind allowing photoelectron spectroscopy on ionic species. • Use of electron-ion coincidence to reduce the background. • Examples on the photoionization of Xe{sup 5+} multiply-charged ion. - Abstract: We describe the merged-beam setup permanently installed on a dedicated optical branch of the PLEIADES beamline at SOLEIL, the French synchrotron radiation facility in St-Aubin, delivering photons in the 10–1000 eV photon energy range. The setup is designed both for photoion and photoelectron spectroscopy experiments on atomic and molecular ions. Ion spectrometry is dedicated to the determination of absolute single and multiple photoionization cross sections. Electron spectroscopy brings additional information on the non-radiative decay of inner-vacancies produced in the photoionization processes and allows for the determination of partial cross sections. Efficient reduction of the background in the electron spectra is achieved by the use of the electron-ion coincidence technique. Examples of photoion and photoelectron spectra are given for the Xe{sup 5+} ion.

  8. An experimental set-up for carbon isotopic analysis of atmospheric ...

    Indian Academy of Sciences (India)

    We present here, an experimental set-up developed for the first time in India for the ... The internal reproducibility (precision) for the δ13C ... interaction of CO2 and water, and reproduce iso- ..... enhanced emission of anthropogenic CO2, varia-.

  9. Antagonistic effect of chosen lactic acid bacteria strains on Yersinia enterocolitica species in model set-ups, meat and fermented sausages.

    Science.gov (United States)

    Gomółka-Pawlicka, M; Uradziński, J

    2003-01-01

    The present study was aimed at determining the influence of 15 strains of lactic acid bacteria on the growth of 8 Yersinia enterocolitica strains in model set-ups, and in meat and ageing fermented sausages. The investigations were performed within the framework of three alternate stages which differed in respect to the products studied, the number of Lactobacillus sp. strains and, partly, methodological approach. The ratio between lactic acid bacteria and Yersinia enterocolitica strains studied was, depending on the variant of experiment, 1:1, 1:2 and 2:1, respectively. The study also considered water activity (aw) and pH of the products investigated. The results suggest that all the lactic acid bacteria strains used within the framework of the model set-ups had antagonistic effect on all the Salmonella sp. strains. However, this ability was not observed with respect to of tested lactic acid bacteria strains in meat and fermented sausage. This ability was possessed by one of the strains investigated--Lactobacillus helveticus T 78. The temperature and time of the incubation of sausages, but not aw and pH, were found to have a distinct influence on the antagonistic interaction between the bacteria tested.

  10. Novel Experimental Setups for In Situ Neutron Diffraction

    DEFF Research Database (Denmark)

    Ahlburg, Jakob; H. Gjørup, Frederik; Mørch, Mathias

    Modern synchrotron and neutron sources provide the intensities needed for performing never-before-seen experiments. With the imminent launch of the scattering facilities MAX IV & ESS, it is interesting to explore novel setups that enable new experiments at these sites. X-ray and neutron technique...... also provide information on the magnetic structure and can probe large bulk samples, allowing the study of compacted powders for use in permanent magnets....

  11. DEAR Monte Carlo simulation versus experimental data in measurements with the DEAR NTP setup

    International Nuclear Information System (INIS)

    Bragadireanu, A.M.; Iliescu, M.; Petrascu, C.; Ponta, T.

    1999-01-01

    The DEAR NTP setup was installed in DAΦNE and is taking background data since February 1999. The goal of this work is to compare the measurements, in terms of charged particle hits (clusters), with the DEAR Monte Carlo simulation, taking into account the main effects due to which the particles are lost from circulating beams: Touschek effect and beam-gas interaction. To be mentioned that, during this period, no collisions between electrons and positrons have been achieved in the DEAR Interaction Point (IP) and consequently we don't have any experimental data concerning the hadronic background coming from φ-decays directly, or as secondary products of hadronic interactions. The NTP setup was shielded using lead and copper which gives a shielding factor of about 4. In parallel with the NTP setup, the signals from two scintillator slabs (150 x 80 x 2 mm) collected by 4 PMTs, positioned bellow the NTP setup and facing the IP, were digitized and counted using a National Instruments Timer/Counter Card. To compare experimental data with results of the Monte Carlo simulation we selected periods with only one circulating beam (electrons or positrons), in order to have a clean data set and we selected data files with CCD occupancy lower than 5%. As concerning the X-rays, the statistics was too poor to perform any quantitative comparison. The comparison between Monte Carlo, CCD data and kaon monitor data, for two beams are shown. It can be seen the agreement is fairly good and promising along the way of checking our routines which describes the experimental setup and the physical processes occurring in the accelerator environment. (authors)

  12. Epizootiology of Perkinsus sp. inCrassostrea gasar oysters in polyculture with shrimps in northeastern Brazil

    Directory of Open Access Journals (Sweden)

    Patricia Mirella da Silva

    2016-03-01

    Full Text Available Abstract Bivalve culture is of considerable economic and social interest in northeastern (NE Brazil. The polyculture is an alternative approach to traditional monoculture for reducing the environmental impact of shrimp farming and improving oyster culture. Perkinsus marinus andPerkinsus olseni were found infecting oysters in NE Brazil and can threaten oyster production. This study evaluatedPerkinsus spp. occurrence in Crassostrea gasar during all production stages. Oyster spats were produced in a hatchery and grown in shrimp ponds in Rio Grande do Norte state.Perkinsus spp. were surveyed by Ray’s fluid thioglycollate medium and confirmed by polymerase chain reaction. Prevalence and intensity of infection were determined in oysters until they reached 7 cm. Results showed that the broodstock was already infected by Perkinsus (60%, but the derived spats were Perkinsus-free. Oyster spats acquired Perkinsus infection when transferred to ponds. The prevalence gradually increased in the seven months following placement in ponds (73%, and then decreased to 17% by the tenth month. The infections were initially mild, but intensity increased at the final growth stage. In conclusion, it is possible to produce Perkinsus-free C. gasar oyster spats from infected broodstock, and their culture in shrimp ponds is feasible.

  13. A review of setup error in supine breast radiotherapy using cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Batumalai, Vikneswary, E-mail: Vikneswary.batumalai@sswahs.nsw.gov.au [South Western Clinical School, University of New South Wales, Sydney, New South Wales (Australia); Liverpool and Macarthur Cancer Therapy Centres, New South Wales (Australia); Ingham Institute of Applied Medical Research, Sydney, New South Wales (Australia); Holloway, Lois [South Western Clinical School, University of New South Wales, Sydney, New South Wales (Australia); Liverpool and Macarthur Cancer Therapy Centres, New South Wales (Australia); Ingham Institute of Applied Medical Research, Sydney, New South Wales (Australia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales (Australia); Institute of Medical Physics, School of Physics, University of Sydney, Sydney, New South Wales (Australia); Delaney, Geoff P. [South Western Clinical School, University of New South Wales, Sydney, New South Wales (Australia); Liverpool and Macarthur Cancer Therapy Centres, New South Wales (Australia); Ingham Institute of Applied Medical Research, Sydney, New South Wales (Australia)

    2016-10-01

    Setup error in breast radiotherapy (RT) measured with 3-dimensional cone-beam computed tomography (CBCT) is becoming more common. The purpose of this study is to review the literature relating to the magnitude of setup error in breast RT measured with CBCT. The different methods of image registration between CBCT and planning computed tomography (CT) scan were also explored. A literature search, not limited by date, was conducted using Medline and Google Scholar with the following key words: breast cancer, RT, setup error, and CBCT. This review includes studies that reported on systematic and random errors, and the methods used when registering CBCT scans with planning CT scan. A total of 11 relevant studies were identified for inclusion in this review. The average magnitude of error is generally less than 5 mm across a number of studies reviewed. The common registration methods used when registering CBCT scans with planning CT scan are based on bony anatomy, soft tissue, and surgical clips. No clear relationships between the setup errors detected and methods of registration were observed from this review. Further studies are needed to assess the benefit of CBCT over electronic portal image, as CBCT remains unproven to be of wide benefit in breast RT.

  14. Assessment of Set-up Accuracy in Tangential Breast Treatment Using Electronic Portal Imaging Device

    International Nuclear Information System (INIS)

    Lee, Byung Koo; Kang, Soo Man

    2012-01-01

    The aim of this study was to investigate the setup accuracy for tangential breast treatment patients using electronic portal image and 2-D reconstruction image Twenty two patients undergoing tangential breast treatment. To explore the setup accuracy, distances between chosen landmarks were taken as reference parameters. The difference between measured reference parameters on simulation films and electronic portal images (EPIs) was calculated as the setup error. A total of 22 simulation films and 110 EPIs were evaluated. In the tangential fields, the calculated reference parameters were the central lung distance (CLD), central soft-tissue distance (CSTD), and above lung distance (ALD), below lung distance (BLD). In the medial tangential field, the average difference values for these parameters were 1.0, -6.4, -2.1 and 2.0, respectively; and the values were 1.5, 2.3, 4.1 and 1.1, respectively. In the lateral tangential field, the average difference values for these parameters were -1.5, -4.3, -2.7 and -1.3, respectively; and the values were 3.3, 2.1, 2.9 and 2.5, respectively. CLD, CSTD, ALD and BLD in the tangential fields are easily identifiable and are helpful for detecting setup errors using EPIs in patients undergoing tangential breast radiotherapy treatment.

  15. Assessment of Set-up Accuracy in Tangential Breast Treatment Using Electronic Portal Imaging Device

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Koo [Dept. of Radiation Oncology, Korea University Anam Hospital, Seoul (Korea, Republic of); Kang, Soo Man [Dept. of Radiation Oncology, Korea University Gospel Hospital, Seoul (Korea, Republic of)

    2012-09-15

    The aim of this study was to investigate the setup accuracy for tangential breast treatment patients using electronic portal image and 2-D reconstruction image Twenty two patients undergoing tangential breast treatment. To explore the setup accuracy, distances between chosen landmarks were taken as reference parameters. The difference between measured reference parameters on simulation films and electronic portal images (EPIs) was calculated as the setup error. A total of 22 simulation films and 110 EPIs were evaluated. In the tangential fields, the calculated reference parameters were the central lung distance (CLD), central soft-tissue distance (CSTD), and above lung distance (ALD), below lung distance (BLD). In the medial tangential field, the average difference values for these parameters were 1.0, -6.4, -2.1 and 2.0, respectively; and the values were 1.5, 2.3, 4.1 and 1.1, respectively. In the lateral tangential field, the average difference values for these parameters were -1.5, -4.3, -2.7 and -1.3, respectively; and the values were 3.3, 2.1, 2.9 and 2.5, respectively. CLD, CSTD, ALD and BLD in the tangential fields are easily identifiable and are helpful for detecting setup errors using EPIs in patients undergoing tangential breast radiotherapy treatment.

  16. A review of setup error in supine breast radiotherapy using cone-beam computed tomography

    International Nuclear Information System (INIS)

    Batumalai, Vikneswary; Holloway, Lois; Delaney, Geoff P.

    2016-01-01

    Setup error in breast radiotherapy (RT) measured with 3-dimensional cone-beam computed tomography (CBCT) is becoming more common. The purpose of this study is to review the literature relating to the magnitude of setup error in breast RT measured with CBCT. The different methods of image registration between CBCT and planning computed tomography (CT) scan were also explored. A literature search, not limited by date, was conducted using Medline and Google Scholar with the following key words: breast cancer, RT, setup error, and CBCT. This review includes studies that reported on systematic and random errors, and the methods used when registering CBCT scans with planning CT scan. A total of 11 relevant studies were identified for inclusion in this review. The average magnitude of error is generally less than 5 mm across a number of studies reviewed. The common registration methods used when registering CBCT scans with planning CT scan are based on bony anatomy, soft tissue, and surgical clips. No clear relationships between the setup errors detected and methods of registration were observed from this review. Further studies are needed to assess the benefit of CBCT over electronic portal image, as CBCT remains unproven to be of wide benefit in breast RT.

  17. A fast-response production-inventory model for deteriorating seasonal products with learning in set-ups

    Directory of Open Access Journals (Sweden)

    Ibraheem Abdul

    2011-10-01

    Full Text Available The classical production-inventory model assumes that both demand and set-up costs are constant. However, in real manufacturing environment, managers usually embark on continuous improvement programmes that often lead to more effective use of tools and machineries and consequently reduction in set-up costs. In fact, constant emphasis on reduction of set-up costs is usually cited as one of the factors responsible for the efficiency of Japanese manufacturing methods. On the other hand, the demand for seasonal product is often characterized by a mixture of time-dependent patterns over the entire season. This paper investigates the effect of learning-based reduction in set-up costs on the optimal schedules and costs of a production-inventory system for deteriorating seasonal products. The demand pattern is a general three-phase ramp-type demand function that represents the various phases of demand commonly observed in many seasonal products in the market. A two-parameter Weibull-distribution function is used for the deterioration of items in order to make the model more generalized and realistic. The study further presents two different multi-period production strategies that can ensure a fast-response to customers’ demand and compare them with the usual single period strategy. The Numerical example and sensitivity analysis shows that learning-based reduction in set-up costs leads to higher production frequency and shorter production runs which are vital aspects of the just-in-time (JIT philosophy.

  18. Three-dimensional patient setup errors at different treatment sites measured by the Tomotherapy megavoltage CT

    Energy Technology Data Exchange (ETDEWEB)

    Hui, S.K.; Lusczek, E.; Dusenbery, K. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Dept. of Therapeutic Radiology - Radiation Oncology; DeFor, T. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Biostatistics and Informatics Core; Levitt, S. [Univ. of Minnesota Medical School, Minneapolis, MN (United States). Dept. of Therapeutic Radiology - Radiation Oncology; Karolinska Institutet, Stockholm (Sweden). Dept. of Onkol-Patol

    2012-04-15

    Reduction of interfraction setup uncertainty is vital for assuring the accuracy of conformal radiotherapy. We report a systematic study of setup error to assess patients' three-dimensional (3D) localization at various treatment sites. Tomotherapy megavoltage CT (MVCT) images were scanned daily in 259 patients from 2005-2008. We analyzed 6,465 MVCT images to measure setup error for head and neck (H and N), chest/thorax, abdomen, prostate, legs, and total marrow irradiation (TMI). Statistical comparisons of the absolute displacements across sites and time were performed in rotation (R), lateral (x), craniocaudal (y), and vertical (z) directions. The global systematic errors were measured to be less than 3 mm in each direction with increasing order of errors for different sites: H and N, prostate, chest, pelvis, spine, legs, and TMI. The differences in displacements in the x, y, and z directions, and 3D average displacement between treatment sites were significant (p < 0.01). Overall improvement in patient localization with time (after 3-4 treatment fractions) was observed. Large displacement (> 5 mm) was observed in the 75{sup th} percentile of the patient groups for chest, pelvis, legs, and spine in the x and y direction in the second week of the treatment. MVCT imaging is essential for determining 3D setup error and to reduce uncertainty in localization at all anatomical locations. Setup error evaluation should be performed daily for all treatment regions, preferably for all treatment fractions. (orig.)

  19. A HPMT based set-up to characterize scintillating crystals

    International Nuclear Information System (INIS)

    D'Ambrosio, C.; Ercoli, C.; Jaaskelainen, S.; Lecoeur, G.; Leutz, H.; Loos, R.; Piedigrossi, D.; Puertolas, D.; Rosso, E.; Schomaker, R.

    1999-01-01

    We have developed a fully automatic measurement set-up, capable of measuring light yields arising from scintillating crystals in a linear range of about four orders of magnitude. The photodetector is a hybrid photomultiplier tube specially developed to optimize linear range and photon detection. Crystal and photodetector are temperature controlled by a closed water circuit, as this is essential when measuring low light yield scintillating crystals with a marked temperature dependence of their light yield. Gamma sources can be placed either on top or on the side of the crystal. In this latter case, the source can be automatically moved by a computer-controlled step motor to provide a uniformity profile of the light yield along the crystal. Tagged and not-tagged operation modes are possible. The whole set-up is computer-controlled in an effort to provide fast and reliable measurements, to characterize many crystals per day. This is important for the quality control of the lead tungstate crystals that will be applied in the electromagnetic calorimeter of the CMS-detector at the LHC at CERN. (author)

  20. A HPMT based set-up to characterize scintillating crystals

    Energy Technology Data Exchange (ETDEWEB)

    D' Ambrosio, C.; Ercoli, C.; Jaaskelainen, S.; Lecoeur, G.; Leutz, H.; Loos, R.; Piedigrossi, D.; Puertolas, D.; Rosso, E.; Schomaker, R

    1999-09-21

    We have developed a fully automatic measurement set-up, capable of measuring light yields arising from scintillating crystals in a linear range of about four orders of magnitude. The photodetector is a hybrid photomultiplier tube specially developed to optimize linear range and photon detection. Crystal and photodetector are temperature controlled by a closed water circuit, as this is essential when measuring low light yield scintillating crystals with a marked temperature dependence of their light yield. Gamma sources can be placed either on top or on the side of the crystal. In this latter case, the source can be automatically moved by a computer-controlled step motor to provide a uniformity profile of the light yield along the crystal. Tagged and not-tagged operation modes are possible. The whole set-up is computer-controlled in an effort to provide fast and reliable measurements, to characterize many crystals per day. This is important for the quality control of the lead tungstate crystals that will be applied in the electromagnetic calorimeter of the CMS-detector at the LHC at CERN. (author)

  1. Setup of Design Concept for the Secondary System of the Sodium Cooled Fast Reactor and Development of Computational Code for the heat balance setup

    International Nuclear Information System (INIS)

    Kim, E. K.; Seong, S. H.; Kim, S. O.; Eoh, J. H.; Han, J. W.; Cha, J. E.

    2010-12-01

    KAERI developed KALIMER-600 on it own way and now is designing the 600MWe actual sized plant for SFR. Nowadays, it is emphasizing the necessity of the evaluation for NSSS design as a part of the verification for SFR design validity. In other words, it means that should be precede the setup of the heat balance and preliminary design for SFR BOP. Turbine composition was configurated to refer SAMCHEON-PO fossil plant which have similar steam condition. The heat balance of SFR BOP was deduced to based on the NSSS boundary condition of the 600MWe actual sized plant. The algorithm of the heat balance calculation program was developed to refer preliminary heat balance data. and then, the setup of the heat balance for SFR BOP was evaluated. In the performance analysis for the preliminary heat balance of the SFR BOP, it was demonstrated that turbine characteristics are similar to reference plant, such as the SAMCHEON-PO fossil plant and the PFBR of the India

  2. Setup of a drift tube muon tracker and calibration of muon tracking in Borexino

    International Nuclear Information System (INIS)

    Bick, Daniel

    2011-04-01

    In this work the setup and commissioning of a drift tube based 3D muon tracking detector are described and its use for the solar neutrino experiment Borexino is presented. After a brief introduction to neutrino physics, the general layout of the detector is presented. It is followed by the description of the reconstruction and calibration algorithms. The performance of the muon tracker is presented and results from the commissioning in Hamburg are shown. The detector is currently operated in the LNGS underground laboratory in Italy at the Borexino experiment. After an introduction to Borexino, the modifications of the muon tracker for its setup at LNGS are described. The setup is used as a reference system to determine the resolution of the Borexino muon tracking which is essential for the tagging of cosmogenic induced 11 C background. Finally, first results are presented. (orig.)

  3. Minimizing SIP Session Re-Setup Delay over Wireless Link in 3G Handover Scenarios

    Directory of Open Access Journals (Sweden)

    Moon Bongkyo

    2010-01-01

    Full Text Available The delay in transmitting SIP messages over the wireless link for session resetup at handover is still major bottleneck for interactive multimedia service. In this paper, a proxy agent-based scheme is proposed to minimize the SIP session setup delay over a wireless link in 3G inter-subnet handover scenarios. This scheme is based on the two characteristics. One is that the major factor of SIP session re-setup delay is generally caused by the retransmissions in the unreliable wireless links, and the other is that most of the fields in request messages as well as response messages are duplicated when a set of SIP messages are exchanged during session re-setup procedure. In this scheme, no change is required in the SIP message processing except for the proxy agents in both BS and MH.

  4. Improvements of low-level radioxenon detection sensitivity by a state-of-the art coincidence setup.

    Science.gov (United States)

    Cagniant, A; Le Petit, G; Gross, P; Douysset, G; Richard-Bressand, H; Fontaine, J-P

    2014-05-01

    The ability to quantify isotopic ratios of 135, 133 m, 133 and 131 m radioxenon is essential for the verification of the Comprehensive Nuclear-Test Ban Treaty (CTBT). In order to improve detection limits, CEA has developed a new on-site setup using photon/electron coincidence (Le Petit et al., 2013. J. Radioanal. Nucl. Chem., DOI : 10.1007/s 10697-013-2525-8.). Alternatively, the electron detection cell equipped with large silicon chips (PIPS) can be used with HPGe detector for laboratory analysis purpose. This setup allows the measurement of β/γ coincidences for the detection of (133)Xe and (135)Xe; and K-shell Conversion Electrons (K-CE)/X-ray coincidences for the detection of (131m)Xe, (133m)Xe and (133)Xe as well. Good energy resolution of 11 keV at 130 keV and low energy threshold of 29 keV for the electron detection were obtained. This provides direct discrimination between K-CE from (133)Xe, (133m)Xe and (131m)Xe. Estimation of Minimum Detectable Activity (MDA) for (131m)Xe is in the order of 1mBq over a 4 day measurement. An analysis of an environmental radioxenon sample using this method is shown. © 2013 The Authors. Published by Elsevier Ltd All rights reserved.

  5. Detection of treatment setup errors between two CT scans for patients with head and neck cancer

    International Nuclear Information System (INIS)

    Ezzell, Leah C.; Hansen, Eric K.; Quivey, Jeanne M.; Xia Ping

    2007-01-01

    Accuracy of treatment setup for head and neck patients undergoing intensity-modulated radiation therapy is of paramount importance. The conventional method using orthogonal portal images can only detect translational setup errors while the most frequent setup errors for head and neck patients could be rotational errors. With the rapid development of image-guided radiotherapy, three-dimensional images are readily acquired and can be used to detect both translational and rotational setup errors. The purpose of this study is to determine the significance of rotational variations between two planning CT scans acquired for each of eight head and neck patients, who experienced substantial weight loss or tumor shrinkage. To this end, using a rigid body assumption, we developed an in-house computer program that utilizes matrix transformations to align point bony landmarks with an incremental best-fit routine. The program returns the quantified translational and rotational shifts needed to align the scans of each patient. The program was tested using a phantom for a set of known translational and rotational shifts. For comparison, a commercial treatment planning system was used to register the two CT scans and estimate the translational errors for these patients. For the eight patients, we found that the average magnitudes and standard deviations of the rotational shifts about the transverse, anterior-posterior, and longitudinal axes were 1.7±2.3 deg., 0.8±0.7 deg., and 1.8±1.1 deg., respectively. The average magnitudes and standard deviations of the translational shifts were 2.5±2.6 mm, 2.9±2.8 mm, 2.7±1.7 mm while the differences detected between our program and the CT-CT fusion method were 1.8±1.3 mm, 3.3±5.4 mm, and 3.0±3.4 mm in the left-right, anterior-posterior, and superior-inferior directions, respectively. A trend of larger rotational errors resulting in larger translational differences between the two methods was observed. In conclusion, conventional

  6. A setup for measurement of beam stability and position using position sensitive detector for Indus-1

    International Nuclear Information System (INIS)

    Nathwani, R.K.; Joshi, D.K.; Tyagi, Y.; Soni, R.S.; Puntambekar, T.A.; Pithawa, C.K.

    2009-01-01

    The 450 MeV electron synchrotron radiation source Indus-1 is operational at RRCAT. A set-up has been developed to measure the relative transverse positional stability of the electron beam and its position with microns resolution using position sensitive photodiodes. The set-up has been installed at the diagnostics beam line of Indus-1. Synchrotron light from photo physics beamline was reflected out by inserting a Ni coated mirror and was focused onto a duo-lateral position sensitive photodiode by using two mirrors of 1.25 meter focal length to obtain unity magnification. The set-up consists of a duo-lateral position sensitive detector (PSD), precision processing electronics and a PC based data acquisition system. A computer program captures the processed signals on to a PC using GPIB interface and displays vertical position of the beam in real time. The paper describes the salient features of the setup developed for measurement of beam stability. (author)

  7. Special set-up and treatment techniques for the radiotherapy of pediatric malignancies

    International Nuclear Information System (INIS)

    Martinez, A.; Donaldson, S.S.; Bagshaw, M.A.

    1977-01-01

    The prevention of serious and long term complications of treatment have become as important a consideration in the therapy of children with malignant disease as the goal of tumor control. This balance requires meticulous treatment planning and attention to the treatment preparation and immobilization techniques when radiotherapy is administered to children. Accurate localization of tumor volume and daily reproducibility is essential for delivering precise irradiation. Four special set-up and treatment techniques which have a specific usefulness in radiotherapy for pediatric malignancies are defined and illustrated with the aid of clinical cases. They include the three point set-up, the split beam technique, the isocentric technique, and the strinking field technique

  8. Surgical robot setup simulation with consistent kinematics and haptics for abdominal surgery.

    Science.gov (United States)

    Hayashibe, Mitsuhiro; Suzuki, Naoki; Hattori, Asaki; Suzuki, Shigeyuki; Konishi, Kozo; Kakeji, Yoshihiro; Hashizume, Makoto

    2005-01-01

    Preoperative simulation and planning of surgical robot setup should accompany advanced robotic surgery if their advantages are to be further pursued. Feedback from the planning system will plays an essential role in computer-aided robotic surgery in addition to preoperative detailed geometric information from patient CT/MRI images. Surgical robot setup simulation systems for appropriate trocar site placement have been developed especially for abdominal surgery. The motion of the surgical robot can be simulated and rehearsed with kinematic constraints at the trocar site, and the inverse-kinematics of the robot. Results from simulation using clinical patient data verify the effectiveness of the proposed system.

  9. Automation and results of Adjacent Band Emission testing

    Science.gov (United States)

    2015-03-01

    Problem Statement : Multiple groups conduct tests in various ways - Outcomes vary based on test setup and assumptions - No standard has been established to conduct such tests - Spectrum is scarce and the need for compliance testing will only increase...

  10. A Magnetic Set-Up to Help Teach Newton's Laws

    Science.gov (United States)

    Panijpan, Bhinyo; Sujarittham, Thanida; Arayathanitkul, Kwan; Tanamatayarat, Jintawat; Nopparatjamjomras, Suchai

    2009-01-01

    A set-up comprising a magnetic disc, a solenoid and a mechanical balance was used to teach first-year physics students Newton's third law with the help of a free body diagram. The image of a floating magnet immobilized by the solenoid's repulsive force should help dispel a common misconception of students as regards the first law: that stationary…

  11. Dose variations caused by setup errors in intracranial stereotactic radiotherapy: A PRESAGE study

    International Nuclear Information System (INIS)

    Teng, Kieyin; Gagliardi, Frank; Alqathami, Mamdooh; Ackerly, Trevor; Geso, Moshi

    2014-01-01

    Stereotactic radiotherapy (SRT) requires tight margins around the tumor, thus producing a steep dose gradient between the tumor and the surrounding healthy tissue. Any setup errors might become clinically significant. To date, no study has been performed to evaluate the dosimetric variations caused by setup errors with a 3-dimensional dosimeter, the PRESAGE. This research aimed to evaluate the potential effect that setup errors have on the dose distribution of intracranial SRT. Computed tomography (CT) simulation of a CIRS radiosurgery head phantom was performed with 1.25-mm slice thickness. An ideal treatment plan was generated using Brainlab iPlan. A PRESAGE was made for every treatment with and without errors. A prescan using the optical CT scanner was carried out. Before treatment, the phantom was imaged using Brainlab ExacTrac. Actual radiotherapy treatments with and without errors were carried out with the Novalis treatment machine. Postscan was performed with an optical CT scanner to analyze the dose irradiation. The dose variation between treatments with and without errors was determined using a 3-dimensional gamma analysis. Errors are clinically insignificant when the passing ratio of the gamma analysis is 95% and above. Errors were clinically significant when the setup errors exceeded a 0.7-mm translation and a 0.5° rotation. The results showed that a 3-mm translation shift in the superior-inferior (SI), right-left (RL), and anterior-posterior (AP) directions and 2° couch rotation produced a passing ratio of 53.1%. Translational and rotational errors of 1.5 mm and 1°, respectively, generated a passing ratio of 62.2%. Translation shift of 0.7 mm in the directions of SI, RL, and AP and a 0.5° couch rotation produced a passing ratio of 96.2%. Preventing the occurrences of setup errors in intracranial SRT treatment is extremely important as errors greater than 0.7 mm and 0.5° alter the dose distribution. The geometrical displacements affect dose delivery

  12. Quantifying Appropriate PTV Setup Margins: Analysis of Patient Setup Fidelity and Intrafraction Motion Using Post-Treatment Megavoltage Computed Tomography Scans

    International Nuclear Information System (INIS)

    Drabik, Donata M.; MacKenzie, Marc A.; Fallone, Gino B.

    2007-01-01

    Purpose: To present a technique that can be implemented in-house to evaluate the efficacy of immobilization and image-guided setup of patients with different treatment sites on helical tomotherapy. This technique uses an analysis of alignment shifts between kilovoltage computed tomography and post-treatment megavoltage computed tomography images. The determination of the shifts calculated by the helical tomotherapy software for a given site can then be used to define appropriate planning target volume internal margins. Methods and Materials: Twelve patients underwent post-treatment megavoltage computed tomography scans on a helical tomotherapy machine to assess patient setup fidelity and net intrafraction motion. Shifts were studied for the prostate, head and neck, and glioblastoma multiforme. Analysis of these data was performed using automatic and manual registration of the kilovoltage computed tomography and post-megavoltage computed tomography images. Results: The shifts were largest for the prostate, followed by the head and neck, with glioblastoma multiforme having the smallest shifts in general. It appears that it might be more appropriate to use asymmetric planning target volume margins. Each margin value reported is equal to two standard deviations of the average shift in the given direction. Conclusion: This method could be applied using individual patient post-image scanning and combined with adaptive planning to reduce or increase the margins as appropriate

  13. HECTOR: A 240kV micro-CT setup optimized for research

    Science.gov (United States)

    Masschaele, Bert; Dierick, Manuel; Van Loo, Denis; Boone, Matthieu N.; Brabant, Loes; Pauwels, Elin; Cnudde, Veerle; Van Hoorebeke, Luc

    2013-10-01

    X-ray micro-CT has become a very powerful and common tool for non-destructive three-dimensional (3D) visualization and analysis of objects. Many systems are commercially available, but they are typically limited in terms of operational freedom both from a mechanical point of view as well as for acquisition routines. HECTOR is the latest system developed by the Ghent University Centre for X-ray Tomography (http://www.ugct.ugent.be) in collaboration with X-Ray Engineering (XRE bvba, Ghent, Belgium). It consists of a mechanical setup with nine motorized axes and a modular acquisition software package and combines a microfocus directional target X-ray source up to 240 kV with a large flat-panel detector. Provisions are made to install a line-detector for a maximal operational range. The system can accommodate samples up to 80 kg, 1 m long and 80 cm in diameter while it is also suited for high resolution (down to 4 μm) tomography. The bi-directional detector tiling is suited for large samples while the variable source-detector distance optimizes the signal to noise ratio (SNR) for every type of sample, even with peripheral equipment such as compression stages or climate chambers. The large vertical travel of 1 m can be used for helical scanning and a vertical detector rotation axis allows laminography experiments. The setup is installed in a large concrete bunker to allow accommodation of peripheral equipment such as pumps, chillers, etc., which can be integrated in the modular acquisition software to obtain a maximal correlation between the environmental control and the CT data taken. The acquisition software does not only allow good coupling with the peripheral equipment but its scripting feature is also particularly interesting for testing new and exotic acquisition routines.

  14. Experimental investigation of combustion instabilities in lean swirl-stabilized partially-premixed flames in single- and multiple-burner setup

    Directory of Open Access Journals (Sweden)

    Christian Kraus

    2016-03-01

    Full Text Available In the present work, combustion instabilities of a modular combustor are investigated. The combustor operates with partially premixed, swirl-stabilized flames and can be operated in single- and different multiple-burner setups. The design parameters of the combustor prevent large-scale flame–flame interactions in the multiple-burner arrangements. The objective is to investigate how the interaction of the swirl jets affects the thermoacoustic stability of the combustor. Results of measurements of pressure oscillations and high-speed OH*-chemiluminescence imaging for the single-burner setup and two multiple-burner setups are discussed. Additionally, results of investigations with different flame characteristics are presented. These are achieved by varying the ratio of the mass flow rates through the swirlers of the double-concentric swirl nozzle. Several unstable modes with high pressure amplitudes are observed in the single-burner setup as well as in the multiple-burner setups. Numerical studies of the acoustic behavior of the combustor setups were performed that indicate that the different geometries show similar acoustic behaviors. The results lead to the conclusion that the interaction of the swirl jets in the multiple-burner setups affects the thermoacoustic response spectrum of the flame even in the absence of large-scale flame–flame interactions. Based on the findings in earlier studies, it is concluded that the differences in the flame response characteristics are induced by the reduction of the swirl intensity in the multiple-burner arrangements, which is caused by the exchange of momentum between the adjacent swirl jets.

  15. Sensor set-up for wireless measurement of automotive rim and wheel parameters in laboratory conditions

    Science.gov (United States)

    Borecki, M.; Prus, P.; Korwin-Pawlowski, M. L.; Rychlik, A.; Kozubel, W.

    2017-08-01

    Modern rims and wheels are tested at the design and production stages. Tests can be performed in laboratory conditions and on the ride. In the laboratory, complex and costly equipment is used, as for example wheel balancers and impact testers. Modern wheel balancers are equipped with electronic and electro-mechanical units that enable touch-less measurement of dimensions, including precision measurement of radial and lateral wheel run-out, automatic positioning and application of the counterweights, and vehicle wheel set monitoring - tread wear, drift angles and run-out unbalance. Those tests are performed by on-wheel axis measurements with laser distance meters. The impact tester enables dropping of weights from a defined height onto a wheel. Test criteria are the loss of pressure of the tire and generation of cracks in the wheel without direct impact of the falling weights. In the present paper, a set up composed of three accelerometers, a temperature sensor and a pressure sensor is examined as the base of a wheel tester. The sensor set-up configuration, on-line diagnostic and signal transmission are discussed.

  16. Setup of a drift tube muon tracker and calibration of muon tracking in Borexino

    Energy Technology Data Exchange (ETDEWEB)

    Bick, Daniel

    2011-04-15

    In this work the setup and commissioning of a drift tube based 3D muon tracking detector are described and its use for the solar neutrino experiment Borexino is presented. After a brief introduction to neutrino physics, the general layout of the detector is presented. It is followed by the description of the reconstruction and calibration algorithms. The performance of the muon tracker is presented and results from the commissioning in Hamburg are shown. The detector is currently operated in the LNGS underground laboratory in Italy at the Borexino experiment. After an introduction to Borexino, the modifications of the muon tracker for its setup at LNGS are described. The setup is used as a reference system to determine the resolution of the Borexino muon tracking which is essential for the tagging of cosmogenic induced {sup 11}C background. Finally, first results are presented. (orig.)

  17. Wastewater treatment in horizontal subsurface flow constructed wetlands using different media (setup stage

    Directory of Open Access Journals (Sweden)

    Abdel Razik A. Zidan

    2015-04-01

    Full Text Available Wastewater treatment through horizontal subsurface flow (HSSF constructed wetlands (CWs using three different treatment media (gravel, pieces of plastic pipes, and shredded tire rubber chips were investigated in Samaha village, Dakahliya, Egypt. The study focused on the wetland setup stage during the first months of its operation (setup stage. In this stage media porosity, bacterial biofilm, and plant roots growth were in progress and it was prior to the operational steady state stage. Objectives of this paper are to study the change in media porosity of HSSF wetland cells in order to estimate duration of wetland setup stage, and to evaluate the use of different bed media on biological oxygen demand (BOD, chemical oxygen demand (COD and total suspended solids (TSS treatment. The results showed that after 180 days of operation, the wetland cells had reached steady porosity and had started stable treatment. Also performance of plastic media bed in pollutants reduction was better than gravel and rubber beds and gravel media was in advanced than rubber media.

  18. The setup of a mobile mobility panel for the Netherlands

    NARCIS (Netherlands)

    Geurs, Karst Teunis; Veenstra, Sander; Thomas, Tom

    2013-01-01

    This paper describes the setup of the Dutch Mobile Mobility Panel project, in which GPS-enabled mobile phones (smartphones) are used as a passive multiple-week and multiple-year travel behaviour data collection tool. The data collection methodology used in the Dutch Mobile Mobility Panel comprised

  19. A cryostatic setup for the low-temperature measurement of thermal diffusivity with the photothermal method

    International Nuclear Information System (INIS)

    Bertolotti, M.; Liakhou, G.; Li Voti, R.; Paoloni, S.; Sibilia, C.; Sparvieri, N.

    1995-01-01

    A cryostatic setup is described to perform photothermal deflection measurements from room temperature to 77 K. The setup uses gaseous nitrogen as a medium where the photodeflection is produced. The ability of the system to work is demonstrated presenting some measurements of thermal diffusivity of high-temperature superconductor samples and of yttrium-iron garnets with variable aluminum content. copyright 1995 American Institute of Physics

  20. A Simple Experimental Setup for Teaching Additive Colors with Arduino

    Science.gov (United States)

    Carvalho, Paulo Simeão; Hahn, Marcelo

    2016-04-01

    The result of additive colors is always fascinating to young students. When we teach this topic to 14- to 16-year-old students, they do not usually notice we use maximum light quantities of red (R), green (G), and blue (B) to obtain yellow, magenta, and cyan colors in order to build the well-known additive color diagram of Fig. 1. But how about using different light intensities for R, G, and B? What colors do we get? This problem of color mixing has been intensively discussed for decades by several authors, as pointed out by Ruiz's "Color Addition and Subtraction Apps" work and the references included therein. An early LED demonstrator for additive color mixing dates back to 1985, and apps to illustrate color mixing are available online. In this work, we describe an experimental setup making use of a microcontroller device: the Arduino Uno. This setup is designed as a game in order to improve students' understanding of color mixing.

  1. A fully automated temperature-dependent resistance measurement setup using van der Pauw method

    Science.gov (United States)

    Pandey, Shivendra Kumar; Manivannan, Anbarasu

    2018-03-01

    The van der Pauw (VDP) method is widely used to identify the resistance of planar homogeneous samples with four contacts placed on its periphery. We have developed a fully automated thin film resistance measurement setup using the VDP method with the capability of precisely measuring a wide range of thin film resistances from few mΩ up to 10 GΩ under controlled temperatures from room-temperature up to 600 °C. The setup utilizes a robust, custom-designed switching network board (SNB) for measuring current-voltage characteristics automatically at four different source-measure configurations based on the VDP method. Moreover, SNB is connected with low noise shielded coaxial cables that reduce the effect of leakage current as well as the capacitance in the circuit thereby enhancing the accuracy of measurement. In order to enable precise and accurate resistance measurement of the sample, wide range of sourcing currents/voltages are pre-determined with the capability of auto-tuning for ˜12 orders of variation in the resistances. Furthermore, the setup has been calibrated with standard samples and also employed to investigate temperature dependent resistance (few Ω-10 GΩ) measurements for various chalcogenide based phase change thin films (Ge2Sb2Te5, Ag5In5Sb60Te30, and In3SbTe2). This setup would be highly helpful for measurement of temperature-dependent resistance of wide range of materials, i.e., metals, semiconductors, and insulators illuminating information about structural change upon temperature as reflected by change in resistances, which are useful for numerous applications.

  2. Vortex-Concept for Radioactivity Release Prevention at NPP: Development of Computational Model of Lab-Scale Experimental Setup

    Energy Technology Data Exchange (ETDEWEB)

    Ullah, Sana; Sung, Yim Man; Park, Jin Soo; Sung Hyung Jin [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The experimental validation of the vortex-like air curtain concept and use of an appropriate CFD modelling approach for analyzing the problem becomes crucial. A lab-scale experimental setup is designed to validate the proposed concept and CFD modeling approach as a part of validation process. In this study, a computational model of this lab-scale experiment setup is developed using open source CFD code OpenFOAM. The computational results will be compared with experimental data for validation purposes in future, when experimental data is available. 1) A computation model of a lab-scale experimental setup, designed to validate the concept of artificial vortex-like airflow generation for application to radioactivity dispersion prevention in the event of severe accident, was developed. 2) The mesh sensitivity study was performed and a mesh of about 2 million cells was found to be sufficient for this setup.

  3. Design and setup of an experiment to investigate the properties of the positronium negative ion

    International Nuclear Information System (INIS)

    Plenge, F.

    2000-01-01

    This diploma thesis describes the design and setup of an experiment to investigate the properties of the positronium negative ion Ps - . The positronium negative ion consists of two electrons in singlet spin state and a positron. It represents the simplest three-boby-system with a bound state. It allows tests of quantum electrodynamics practically free from complications due to strong interactions and is of particular interest as its investigation might contribute to a solution of the o-Ps-lifetime-puzzle. The present work particularly focuses on the preparation of the experimental tools necessary to study the Ps - -formation mechanisms and to measure the lifetime of the positronium ion. (orig.) [de

  4. Controlling Mechatronic Set-up Using Real-time Linux and CTC ++

    NARCIS (Netherlands)

    Broenink, Johannes F.; Jovanovic, D.S.; Hilderink, G.H.; van Amerongen, J.; Jonker, B.; Regtien, P.; Stramigioli, S.

    2002-01-01

    The development of control software for mechatronic systems is presented by means of a case study: a 2 DOF mechanical rotational set-up usable as a camera-positioning device. The control software is generated using the code generation facility of 20-SIM, thus guaranteeing the generated code being

  5. SED16 autonomous star tracker night sky testing

    Science.gov (United States)

    Foisneau, Thierry; Piriou, Véronique; Perrimon, Nicolas; Jacob, Philippe; Blarre, Ludovic; Vilaire, Didier

    2017-11-01

    The SED16 is an autonomous multi-missions star tracker which delivers three axis satellite attitude in an inertial reference frame and the satellite angular velocity with no prior information. The qualification process of this star sensor includes five validation steps using optical star simulator, digitized image simulator and a night sky tests setup. The night sky testing was the final step of the qualification process during which all the functions of the star tracker were used in almost nominal conditions : Autonomous Acquisition of the attitude, Autonomous Tracking of ten stars. These tests were performed in Calern in the premises of the OCA (Observatoire de la Cote d'Azur). The test set-up and the test results are described after a brief review of the sensor main characteristics and qualification process.

  6. Setup of Mössbauer spectrometers at RCPTM

    Science.gov (United States)

    Pechoušek, J.; Jančík, D.; Frydrych, J.; Navařík, J.; Novák, P.

    2012-10-01

    Setup of Mössbauer spectrometers (MS) for structural, phase, and magnetic characterization of iron-or tin-containing samples is presented. This comprehensive line of 57Fe and 119Sn Mössbauer spectrometers covers transmission spectrometers (TMS) for roomtemperature (RT) measurements, temperature dependent measurements and measurements in an external magnetic field. An RT Conversion Electron/Conversion X-ray Mössbauer technique (CEMS/CXMS) is also available. The main concept of the RT MS is a table-top spectrometric bench with a control unit based on special-purpose hardware or standard PC platform. The first way offers a compact design and PC independent spectra collection system. The second setup, a PC-based system, which uses commercial devices and LabVIEW software, offers easy customization and enables advancement in spectrometer construction. The both types of control systems are able to operate special parts (velocity transducers, gamma-ray detectors) of unusual spectrometric benches. The standard velocity axis range is up to ±20 mm/s with a maximum nonlinearity of 0.1%. Applicable measuring conditions of presented TMSs cover a cryogenic temperature range from 1.5 up to 300 K and high temperature range from RT up to 1000 °C. With in-field low-temperature MS, we are able to analyze samples normally in the external magnetic fields up to 8 T (in temperature interval from 1.5 up to 300 K). In addition, special modes of measurements can be applied including backscattering gamma-ray geometry or measurement in an inert or controlled-humidity atmosphere. Technical details and construction aspects of spectrometers are presented.

  7. Test One to Test Many: A Unified Approach to Quantum Benchmarks

    Science.gov (United States)

    Bai, Ge; Chiribella, Giulio

    2018-04-01

    Quantum benchmarks are routinely used to validate the experimental demonstration of quantum information protocols. Many relevant protocols, however, involve an infinite set of input states, of which only a finite subset can be used to test the quality of the implementation. This is a problem, because the benchmark for the finitely many states used in the test can be higher than the original benchmark calculated for infinitely many states. This situation arises in the teleportation and storage of coherent states, for which the benchmark of 50% fidelity is commonly used in experiments, although finite sets of coherent states normally lead to higher benchmarks. Here, we show that the average fidelity over all coherent states can be indirectly probed with a single setup, requiring only two-mode squeezing, a 50-50 beam splitter, and homodyne detection. Our setup enables a rigorous experimental validation of quantum teleportation, storage, amplification, attenuation, and purification of noisy coherent states. More generally, we prove that every quantum benchmark can be tested by preparing a single entangled state and measuring a single observable.

  8. The new external ion beam analysis setup at the Demokritos Tandem accelerator and first applications in cultural heritage

    International Nuclear Information System (INIS)

    Sokaras, Dimosthenis; Bistekos, Euthimios; Georgiou, Lambros; Salomon, Joseph; Bogovac, Mladen; Aloupi-Siotis, Eleni; Paschalis, Vasilis; Aslani, Ioanna; Karabagia, Sofia; Lagoyannis, Anastasios; Harissopulos, Sotirios; Kantarelou, Vasiliki; Karydas, Andreas-Germanos

    2011-01-01

    At the 5.5 MV Tandem VdG accelerator of the Institute of Nuclear Physics of N.C.S.R. 'Demokritos', Athens, Greece, an external ion-beam set-up has been recently developed and installed. The aim of this development was to integrate the analytical capabilities of the PIXE, RBS and PIGE ion beam techniques in one experimental set-up, so that to attain a complete elemental and near surface structural characterization of samples in an almost non-destructive way and without any limitation concerning their size or conductive state. A careful 3D mechanical drawing optimized the set-up experimental parameters achieving probe dimensions at the millimeter range (1 mm 2 ) and fulfilling the special requirements imposed for optimum performance of the aforementioned techniques, including the possibility to use heavier, than protons, ion beams. For the digital pulse processing of the X-ray, γ-ray and charged particle detector signals, novel hardware and software tools were developed based on a custom FPGA configuration. The first applications were focused in the quality control of materials that have been intentionally contaminated with a particular tracer-element ('tagged' materials). The tagged materials which were developed and tested are technologically authentic replicas of ancient attic ceramics with black glazed decoration. Analytical diagnostic studies were carried out for a few representative paintings of contemporary Greek painters in order to identify and document materials/pigments and techniques and eventually to prevent trade of fakes. Finally, ancient glass beads were also examined with respect to the sodium concentration and its in-depth homogeneity.

  9. Testing cooperative systems with the MARS simulator

    NARCIS (Netherlands)

    Netten, B.D.; Wedemeijer, H.

    2010-01-01

    The complexity of cooperative systems makes the use of high fidelity simulation essential in the development and testing of cooperative applications and their interactions with other cooperative systems. In SAFESPOT a simulator test bench is setup to test the safety margin applications running on

  10. Last Stand-alone Beam Test of the Hadronic End-cap Calorimeter (HEC) Finished.

    CERN Multimedia

    Oberlack, H

    One quarter of all 134 HEC modules are tested with electron, pion and muon beams: two "partial HEC wheels", three HEC1 modules and three HEC2 modules, are used in a standard setup using the HEC cryostat in the H6 beam line. The picture shows a view of the set-up in the cryostat during the installation. MC results show that in this setup the energy leakage is well under control - well below 5 %. In addition, the other three quarters of modules are tested in technical cold tests. Using calibration signals, a detailed test of the cabling, cold electronics, crosstalk and noise performance is being done. The beam tests started with four prototype modules per run in '97, when technological optimization was still the key issue. From '98 onwards, modules of the "module 0" type have been tested, typically in two run periods per year. Finally in '99 the series production has started, with first beam test of series modules in 2000. Since then 57 series modules have been cold tested, 24 of them actually in beam tests. T...

  11. Laboratory setup for temperature and humidity measurements

    CERN Document Server

    Eimre, Kristjan

    2015-01-01

    In active particle detectors, the temperature and humidity conditions must be under constant monitoring and control, as even small deviations from the norm cause changes to detector characteristics and result in a loss of precision. To monitor the temperature and humidity, different kinds of sensors are used, which must be calibrated beforehand to ensure their accuracy. To calibrate the large number of sensors that are needed for the particle detectors and other laboratory work, a calibration system is needed. The purpose of the current work was to develop a laboratory setup for temperature and humidity sensor measurements and calibration.

  12. The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer

    International Nuclear Information System (INIS)

    Manning, Matthew A.; Wu Quiwen; Cardinale, Robert M.; Mohan, Radhe; Lauve, Andrew D.; Kavanagh, Brian D.; Morris, Monica M.; Schmidt-Ullrich, Rupert K.

    2001-01-01

    Purpose: Intensity-modulated radiotherapy (IMRT) is being evaluated in the management of head-and-neck cancers at several institutions, and a Radiation Therapy Oncology Group study of its utility in parotid sparing is under development. There is an inherent risk that the sharper dose gradients generated by IMRT amplify the potentially detrimental impact of setup uncertainty. The International Commission on Radiation Units and Measurements Report 62 (ICRU-62) defined planning organ-at-risk volume (PRV) to account for positional uncertainties for normal tissues. The purpose of this study is to quantify the dosimetric effect of employing PRV for the parotid gland and to evaluate the use of PRV on normal-tissue sparing in the setting of small clinical setup errors. Methods and Materials: The optimized nine-beam IMRT plans for three head-and-neck cancer patients participating in an institutional review board approved parotid-sparing protocol were used as reference plans. A second optimized plan was generated for each patient by adding a PRV of 5 mm for the contralateral parotid gland. The effect of these additions on the quality of the plans was quantified, in terms of both target coverage and normal-tissue sparing. To test the value of PRV in a worst-case scenario, systematic translational setup uncertainties were simulated by shifting the treatment isocenter 5 mm superiorly, inferiorly, left, right, anteriorly, and posteriorly, without altering optimized beam profiles. At each shifted isocenter, dose distributions were recalculated, producing a total of six shifted plans without PRV and six shifted plans with PRV for each patient. The effect of setup uncertainty on parotid sparing and the value of PRV in compensating for the uncertainty were evaluated. Results: The addition of the PRV and reoptimization did not significantly affect the dose to gross tumor volume, spinal cord, or brainstem. In contrast, without any shift, the PRV did increase parotid sparing and reduce

  13. ATLAS superconducting solenoid on-surface test

    CERN Document Server

    Ruber, Roger J M Y; Doi, Y; Haruyama, T; Haug, F; ten Kate, H H J; Kawai, M; Kondo, T; Kondo, Y; Makida, Y; Mizumaki, S; Olesen, G; Pavlov, O V; Pezzetti, M; Pirotte, O; Sbrissa, E; Yamamoto, A

    2005-01-01

    The ATLAS detector is presently under construction as one of the five LHC experiment set-ups. It relies on a sophisticated magnet system for the momentum measurement of charged particle tracks. The superconducting solenoid is at the center of the detector, the magnet system part nearest to the proton-proton collision point. It is designed for a 2 Tesla strong axial magnetic field at the collision point, while its thin-walled construction of 0.66 radiation lengths avoids degradation of energy measurements in the outer calorimeters. The solenoid and calorimeter have been integrated in their common cryostat, cooled down and tested on-surface. We review the on-surface set-up and report the performance test results.

  14. Response of a PGNAA setup for pozzolan-based cement concrete specimens

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Garwan, M.A.; Maslehuddin, M.; Nagadi, M.M.; Al-Amoudi, O.S.B.; Raashid, M.

    2010-01-01

    Pozzolanic materials are added to Portland cement concrete to increase its durability, particularly corrosion-resistance. In this study the elemental composition of a pozzolanic cement concrete was measured non-destructively utilizing an accelerator-based Prompt Gamma Ray Neutron Activation Analysis (PGNAA) setup. The optimum size of the pozzolanic cement concrete specimen was obtained through Monte Carlo simulations. The simulation results were experimentally verified through the γ-ray yield measurement from the pozzolanic cement concrete specimens as a function of their radii. The concentration of the pozzolanic material in the cement concrete specimens was evaluated by measuring γ-ray yield for calcium and iron from pozzolanic cement concrete specimens containing 5-80 wt% pozzolan. A good agreement was noted between the experimental values and the Monte Carlo simulation results, indicating an excellent response of the KFUPM accelerator-based PGNAA setup for pozzolan based concrete.

  15. Response of a PGNAA setup for pozzolan-based cement concrete specimens

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)], E-mail: aanaqvi@kfupm.edu.sa; Garwan, M.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Maslehuddin, M. [Center for Engineering Research, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Raashid, M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2010-04-15

    Pozzolanic materials are added to Portland cement concrete to increase its durability, particularly corrosion-resistance. In this study the elemental composition of a pozzolanic cement concrete was measured non-destructively utilizing an accelerator-based Prompt Gamma Ray Neutron Activation Analysis (PGNAA) setup. The optimum size of the pozzolanic cement concrete specimen was obtained through Monte Carlo simulations. The simulation results were experimentally verified through the {gamma}-ray yield measurement from the pozzolanic cement concrete specimens as a function of their radii. The concentration of the pozzolanic material in the cement concrete specimens was evaluated by measuring {gamma}-ray yield for calcium and iron from pozzolanic cement concrete specimens containing 5-80 wt% pozzolan. A good agreement was noted between the experimental values and the Monte Carlo simulation results, indicating an excellent response of the KFUPM accelerator-based PGNAA setup for pozzolan based concrete.

  16. Sensitivity testing of the model set-up used for calculation of photochemical ozone creation potentials (POCP) under European conditions

    Energy Technology Data Exchange (ETDEWEB)

    Altenstedt, J.; Pleijel, K.

    1998-02-01

    Photochemical Ozone Creation Potentials (POCP) is a method to rank VOC, relative to other VOC, according to their ability to produce ground level ozone. To obtain POCP values valid under European conditions, a critical analysis of the POCP concept has been performed using the IVL photochemical trajectory model. The critical analysis has concentrated on three VOC (ethene, n-butane and o-xylene) and has analysed the effect on their POCP values when different model parameters were varied. The three species were chosen because of their different degradation mechanisms in the atmosphere and thus their different abilities to produce ozone. The model parameters which have been tested include background emissions, initial concentrations, dry deposition velocities, the features of the added point source and meteorological parameters. The critical analysis shows that the background emissions of NO{sub x} and VOC have a critical impact on the POCP values. The hour of the day for the point source emission also shows a large influence on the POCP values. Other model parameters which have been studied have not shown such large influence on the POCP values. Based on the critical analysis a model set-up for calculation of POCP is defined. The variations in POCP values due to changes in the background emissions of NO{sub x} and VOC are so large that they can not be disregarded in the calculation of POCP. It is recommended to calculate POCP ranges based on the extremes in POCP values instead of calculating site specific POCP values. Four individual emission scenarios which produced the extremes in POCP values in the analysis have been selected for future calculation of POCP ranges. The scenarios are constructed based on the emissions in Europe and the resulting POCP ranges are thus intended to be applicable within Europe 67 refs, 61 figs, 16 tabs

  17. Approaching Repetitive Short Circuit Tests on MW-Scale Power Modules by means of an Automatic Testing Setup

    DEFF Research Database (Denmark)

    Reigosa, Paula Diaz; Wang, Huai; Iannuzzo, Francesco

    2016-01-01

    An automatic testing system to perform repetitive short-circuit tests on megawatt-scale IGBT power modules is pre-sented and described in this paper, pointing out the advantages and features of such testing approach. The developed system is based on a non-destructive short-circuit tester, which has...

  18. The culture of pearl oysters, Pinctada fucata (Gould, 1850 in Phuket with temperature shock method and survival rates on various feeds

    Directory of Open Access Journals (Sweden)

    Rativat, V.

    2005-02-01

    Full Text Available Marine pearl farming at Phuket Island has exploited natural pearl oysters. In order to obtain sufficient pearl oysters, Pinctada fucata (Gould, 1850, the oyster cultivation was carried out to determine appropriate kinds of food and types of spat collectors. The male and female oysters were stimulated to spawn with this temperature shock method (treated with 32ºC and then with 26ºC. The fertilized eggs developed into the stages of polar body, cleavage, blastula, gastrula, trochophore and then D-shape larvae. At the ageof 19-26 hrs. the larvae were fed with three kinds of food: Isochrysis galbana, Chaetoceros calcitrans and the mixture of 1:1 I. galbana and C. calcitrans. Upon the first 30 days, shell lengths of the spats fed with I. Galbana, C. calcitrans and the mixture were 422.00±59.32, 221.33±12.46 and 347.33±67.98 μg, respectively. The 26-29th day spat stage settled to the collectors: saran net, plastic plates and wavy tile. Number of spats settling to saran net was the highest. But after being moved into the sea for 30 days, the survival rate was89.06% which was lower than for those settling to plastic plates (93.29% and wavy tile (93.99%.

  19. Features investigation of corrosion-electrochemical behaviour of Al-alloys for engineering an effective protection of the water-distillings setups

    International Nuclear Information System (INIS)

    Fokin, M.N.; Lomakina, S.V.; Tselykh, O.G.; Shatova, T.S.; Trubetskaya, L.F.

    1993-01-01

    The problem of aluminium alloy application in distilling setups is studied. Investigation into the features of corrosion and electrochemical behaviour of aluminium alloys under sea water distillation allows one to reveal the main control factors and to propose optimal alloy compositions capable of providing the safe setup operation on their base. Preliminary treatment in tungsten and molybdenum isopolycompound solutions is proposed which reduces sedimentation which in its turn is very important for distilling setups

  20. Refinement of Treatment Setup and Target Localization Accuracy Using Three-Dimensional Cone-Beam Computed Tomography for Stereotactic Body Radiotherapy

    International Nuclear Information System (INIS)

    Wang Zhiheng; Nelson, John W.; Yoo, Sua; Wu, Q. Jackie; Kirkpatrick, John P.; Marks, Lawrence B.; Yin Fangfang

    2009-01-01

    Purposes: To quantitatively compare two-dimensional (2D) orthogonal kV with three-dimensional (3D) cone-beam CT (CBCT) for target localization; and to assess intrafraction motion with kV images in patients undergoing stereotactic body radiotherapy (SBRT). Methods and Materials: A total of 50 patients with 58 lesions received 178 fractions of SBRT. After clinical setup using in-room lasers and skin/cradle marks placed at simulation, patients were imaged and repositioned according to orthogonal kV/MV registration of bony landmarks to digitally reconstructed radiographs from the planning CT. A subsequent CBCT was registered to the planning CT using soft tissue information, and the resultant 'residual error' was measured and corrected before treatment. Posttreatment 2D kV and/or 3D CBCT images were compared with pretreatment images to determine any intrafractional position changes. Absolute averages, statistical means, standard deviations, and root mean square (RMS) values of observed setup error were calculated. Results: After initial setup to external marks with laser guidance, 2D kV images revealed vector mean setup deviations of 0.67 cm (RMS). Cone-beam CT detected residual setup deviations of 0.41 cm (RMS). Posttreatment imaging demonstrated intrafractional variations of 0.15 cm (RMS). The individual shifts in three standard orthogonal planes showed no obvious directional biases. Conclusions: After localization based on superficial markings in patients undergoing SBRT, orthogonal kV imaging detects setup variations of approximately 3 to 4 mm in each direction. Cone-beam CT detects residual setup variations of approximately 2 to 3 mm

  1. Optimized linear motor and digital PID controller setup used in Mössbauer spectrometer

    Science.gov (United States)

    Kohout, Pavel; Kouřil, Lukáš; Navařík, Jakub; Novák, Petr; Pechoušek, Jiří

    2014-10-01

    Optimization of a linear motor and digital PID controller setup used in a Mössbauer spectrometer is presented. Velocity driving system with a digital PID feedback subsystem was developed in the LabVIEW graphical environment and deployed on the sbRIO real-time hardware device (National Instruments). The most important data acquisition processes are performed as real-time deterministic tasks on an FPGA chip. Velocity transducer of a double loudspeaker type with a power amplifier circuit is driven by the system. Series of calibration measurements were proceeded to find the optimal setup of the P, I, D parameters together with velocity error signal analysis. The shape and given signal characteristics of the velocity error signal are analyzed in details. Remote applications for controlling and monitoring the PID system from computer or smart phone, respectively, were also developed. The best setup and P, I, D parameters were set and calibration spectrum of α-Fe sample with an average nonlinearity of the velocity scale below 0.08% was collected. Furthermore, the width of the spectral line below 0.30 mm/s was observed. Powerful and complex velocity driving system was designed.

  2. Laboratory tests of hydraulic fracturing and swell healing

    DEFF Research Database (Denmark)

    Thunbo, Christensen Claes; Foged, Christensen Helle; Foged, Niels

    1998-01-01

    New laboratory test set-ups and test procedures are described - for testing the formation of hydraulically induced fractures as well as the potential for subsequent fracture closurefrom the relase of a swelling potential. The main purpose with the tests is to provide information on fracturing str...

  3. Setup for fission and evaporation cross-section measurements in reactions induced by secondary beams

    International Nuclear Information System (INIS)

    Hassan, A.A.; Luk'yanov, S.M.; Kalpakchieva, R.; Skobelev, N.K.; Penionzhkevich, Yu.Eh.; Dlouhy, Z.; Radnev, S.; Poroshin, N.V.

    2002-01-01

    A setup for studying reactions induced by secondary radioactive beams has been constructed. It allows simultaneous measurement of α-particle and fission fragment energy spectra. By measuring the α-particles, identification of evaporation residues is achieved. A set of three targets can be used so as to ensure sufficient statistics. Two silicon detectors, located at 90 degrees to the secondary beam direction, face each target, thus covering 30% of the solid angle. This experimental setup is to be used to obtain excitation functions of fusion-fission reactions and of reactions leading to evaporation residue production

  4. A flexible experimental setup for femtosecond time-resolved broad-band ellipsometry and magneto-optics

    Energy Technology Data Exchange (ETDEWEB)

    Boschini, F.; Hedayat, H.; Piovera, C.; Dallera, C. [Dipartimento di Fisica, Politecnico di Milano, p.zza Leonardo da Vinci 32, 20133 Milano (Italy); Gupta, A. [Department of Chemistry, University of Alabama, Tuscaloosa, Alabama 35487 (United States); Carpene, E., E-mail: ettore.carpene@polimi.it [CNR-IFN, Dipartimento di Fisica, Politecnico di Milano, p.zza Leonardo da Vinci 32, 20133 Milano (Italy)

    2015-01-15

    A versatile experimental setup for femtosecond time-resolved ellipsometry and magneto-optical Kerr effect measurements in the visible light range is described. The apparatus is based on the pump-probe technique and combines a broad-band probing beam with an intense near-infrared pump. According to Fresnel scattering matrix formalism, the analysis of the reflected beam at different polarization states of the incident probe light allows one to determine the diagonal and the off-diagonal elements of the dielectric tensor in the investigated sample. Moreover, the pump-probe method permits to study the dynamics of the dielectric response after a short and intense optical excitation. The performance of the experimental apparatus is tested on CrO{sub 2} single crystals as a benchmark.

  5. A flexible experimental setup for femtosecond time-resolved broad-band ellipsometry and magneto-optics

    International Nuclear Information System (INIS)

    Boschini, F.; Hedayat, H.; Piovera, C.; Dallera, C.; Gupta, A.; Carpene, E.

    2015-01-01

    A versatile experimental setup for femtosecond time-resolved ellipsometry and magneto-optical Kerr effect measurements in the visible light range is described. The apparatus is based on the pump-probe technique and combines a broad-band probing beam with an intense near-infrared pump. According to Fresnel scattering matrix formalism, the analysis of the reflected beam at different polarization states of the incident probe light allows one to determine the diagonal and the off-diagonal elements of the dielectric tensor in the investigated sample. Moreover, the pump-probe method permits to study the dynamics of the dielectric response after a short and intense optical excitation. The performance of the experimental apparatus is tested on CrO 2 single crystals as a benchmark

  6. Patient setup aid with wireless CCTV system in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yang Kyun; Cho, Woong; Park, Jong Min [Seoul National University Graduate School, Seoul (Korea, Republic of); Ha, Sung Whan; Ye, Sung Joon [Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Suk Won [Chung-Ang University Cellege of Medicine, Seoul (Korea, Republic of); Huh, Soon Nyung [Seoul National University Hospital, Seoul (Korea, Republic of)

    2006-12-15

    To develop a wireless CCTV system in semi-beam's eye view (BEV) to monitor daily patient setup in radiation therapy. In order to get patient images in semi-BEV, CCTV cameras are installed in a custom-made acrylic applicator below the treatment head of a linear accelerator. The images from the cameras are transmitted via radio frequency signal ( {approx} 2.4 GHz and 10 mW RF output). An expected problem with this system is radio frequency interference, which is solved utilizing RF shielding with Cu foils and median filtering software. The images are analyzed by our custom-made software. In the software, three anatomical landmarks in the patient surface are indicated by a user, then automatically the 3 dimensional structures are obtained and registered by utilizing a localization procedure consisting mainly of stereo matching algorithm and Gauss-Newton optimization. This algorithm is applied to phantom images in investigate the setup accuracy. Respiratory gating system is also researched with real-time image processing. A line-laser marker projected on a patient's surface is extracted by binary image processing and the breath pattern is calculated and displayed in real-time. More than 80% of the camera noises from the linear accelerator are eliminated by wrapping the camera with copper foils. The accuracy of the localization procedure is found to be on the order of 1.5 {+-} 0.7 mm with a point phantom and sub-millimeters and degrees with a custom-made head/neck phantom. With line-laser marker, real-time respiratory monitoring is possible in the delay time of {approx} 0.7 sec. The wireless CCTV camera system is the novel tool which can monitor daily patient setups. The feasibility of respiratory gating system with the wireless CCTV is hopeful.

  7. Patient setup aid with wireless CCTV system in radiation therapy

    International Nuclear Information System (INIS)

    Park, Yang Kyun; Cho, Woong; Park, Jong Min; Ha, Sung Whan; Ye, Sung Joon; Park, Suk Won; Huh, Soon Nyung

    2006-01-01

    To develop a wireless CCTV system in semi-beam's eye view (BEV) to monitor daily patient setup in radiation therapy. In order to get patient images in semi-BEV, CCTV cameras are installed in a custom-made acrylic applicator below the treatment head of a linear accelerator. The images from the cameras are transmitted via radio frequency signal ( ∼ 2.4 GHz and 10 mW RF output). An expected problem with this system is radio frequency interference, which is solved utilizing RF shielding with Cu foils and median filtering software. The images are analyzed by our custom-made software. In the software, three anatomical landmarks in the patient surface are indicated by a user, then automatically the 3 dimensional structures are obtained and registered by utilizing a localization procedure consisting mainly of stereo matching algorithm and Gauss-Newton optimization. This algorithm is applied to phantom images in investigate the setup accuracy. Respiratory gating system is also researched with real-time image processing. A line-laser marker projected on a patient's surface is extracted by binary image processing and the breath pattern is calculated and displayed in real-time. More than 80% of the camera noises from the linear accelerator are eliminated by wrapping the camera with copper foils. The accuracy of the localization procedure is found to be on the order of 1.5 ± 0.7 mm with a point phantom and sub-millimeters and degrees with a custom-made head/neck phantom. With line-laser marker, real-time respiratory monitoring is possible in the delay time of ∼ 0.7 sec. The wireless CCTV camera system is the novel tool which can monitor daily patient setups. The feasibility of respiratory gating system with the wireless CCTV is hopeful

  8. Technologies for the Fast Set-Up of Automated Assembly Processes

    DEFF Research Database (Denmark)

    Krüger, Norbert; Ude, Ales; Petersen, Henrik Gordon

    2014-01-01

    of so called few-of-a-kind production. Therefore, most production of this kind is done manually and thus often performed in low-wage countries. In the IntellAct project, we have developed a set of methods which facilitate the set-up of a complex automatic assembly process, and here we present our work...

  9. Fast evaluation of patient set-up during radiotherapy by aligning features in portal and simulator images

    International Nuclear Information System (INIS)

    Bijhold, J.; Herk, M. van; Vijlbrief, R.; Lebesque, J.V.

    1991-01-01

    A new fast method is presented for the quantification of patient set-up errors during radiotherapy with external photon beams. The set-up errors are described as deviations in relative position and orientation of specified anatomical structures relative to specified field shaping devices. These deviations are determined from parameters of the image transformations that make their features in a portal image align with the corresponding features in a simulator image. Knowledge of some set-up parameters during treatment simulation is required. The method does not require accurate knowledge about the position of the portal imaging device as long as the positions of some of the field shaping devices are verified independently during treatment. By applying this method, deviations in a pelvic phantom set-up can be measured with a precision of 2 mm within 1 minute. Theoretical considerations and experiments have shown that the method is not applicable when there are out-of-plane rotations larger than 2 degrees or translations larger than 1 cm. Inter-observer variability proved to be a source of large systematic errors, which could be reduced by offering a precise protocol for the feature alignment. (author)

  10. Simulating flood risk under non-stationary climate and urban development conditions - Experimental setup for multiple hazards and a variety of scenarios

    DEFF Research Database (Denmark)

    Löwe, Roland; Urich, Christian; Kulahci, Murat

    2018-01-01

    vulnerability resulting from urban growth. The framework is embedded in an experimental setup where flood damage obtained from combined hydraulic-urban development simulations is approximated using kriging-metamodels. Space-filling, sequential and stratified sequential sampling strategies are tested. Reliable...... options implemented over short time horizons. However, the number of simulations is reduced by up to one order of magnitude compared to scenario-based methods, highlighting the potential of the approach....

  11. The setup to investigate rare processes with neutron producing

    International Nuclear Information System (INIS)

    Bystritskij, V.M.; Zhuravlev, N.I.; Merzlyakov, S.I.; Sidorov, V.T.; Stolupin, V.A.; Strelkov, A.V.; Shvetsov, V.N.

    1995-01-01

    An experimental setup has been created to study rare processes with neutron production. The detecting system comprises a scintillation detector in the form of a cup around which thermal neutron detectors (BF3 counters) set in paraffin are placed parallel to the common axis in two concentric circles. The detecting system and registering electronics make it possible to obtain time and amplitude information for each registered event. 8 refs., 5 figs

  12. Method and apparatus for checking the stability of a setup for making reflection type holograms

    Science.gov (United States)

    Lackner, H. G. (Inventor)

    1974-01-01

    A method and apparatus are described for checking the stability of a setup for recording reflection-type (white light) holograms. Two sets of interference fringes are simultaneously obtained, one giving information about coherence and stability of the setup alone and the other demonstrating coherence of the entire system, including the holographic recording plate. Special emphasis is given to the stability of the plate, due to the fact that any minute vibration might severely degrade or completely destroy the recording.

  13. Development of novel whole-body exposure setups for rats providing high efficiency, National Toxicology Program (NTP) compatibility and well-characterized exposure

    Energy Technology Data Exchange (ETDEWEB)

    Kainz, Wolfgang [Food and Drug Administration (FDA), Center for Devices and Radiological Health (CDRH), 12725 Twinbrook Parkway, Rockville, MD 20852 (United States); Nikoloski, Neviana [IT' IS Foundation-The Foundation for Research on Information Technologies in Society, ETH Zurich, 8092 Zurich (Switzerland); Oesch, Walter [IT' IS Foundation-The Foundation for Research on Information Technologies in Society, ETH Zurich, 8092 Zurich (Switzerland); Berdinas-Torres, Veronica [IT' IS Foundation-The Foundation for Research on Information Technologies in Society, ETH Zurich, 8092 Zurich (Switzerland); Froehlich, Juerg [IT' IS Foundation-The Foundation for Research on Information Technologies in Society, ETH Zurich, 8092 Zurich (Switzerland); Neubauer, Georg [ARC Seibersdorf research GmbH, Kramergasse 1, A-1010 Vienna (Austria); Kuster, Niels [IT' IS Foundation-The Foundation for Research on Information Technologies in Society, ETH Zurich, 8092 Zurich (Switzerland)

    2006-10-21

    This paper presents the design, optimization, realization and verification of novel whole-body exposure setups for rats. The setups operating at 902 MHz and 1747 MHz provide highly efficient, National Toxicology Program (NTP) compatible and well-characterized exposures. They are compared to existing concepts of exposure setups with respect to efficiency, induced field uniformity, good laboratory practice (GLP) compatibility and cost. The novel exposure setup consists of a circular cascade of 17 sectorial waveguides excited by a novel loop antenna placed in the centre. The 70% overall efficiency of the exposure setup surpasses comparable values of existing setups. A field uniformity inside the phantom of more than 86% for the 1g cubical averaged specific absorption rate (SAR) within {+-}5 dB of the whole-body SAR (WB-SAR) was attained. The uniformity of the exposure inside the setup, defined as the variation of the WB-SAR between animals, was better than {+-}24%. Using only stainless steel, gold and polycarbonate in the vicinity of the animals ensured full GLP compatibility. The entire exposure system features fully automated computer controlled exposure and data monitoring, data storing and failure handling. Therefore, the proposed exposure system can be used to run blinded large scale, long-term exposure studies.

  14. A new setup for the investigation of swift heavy ion induced particle emission and surface modifications

    Energy Technology Data Exchange (ETDEWEB)

    Meinerzhagen, F.; Breuer, L.; Bukowska, H.; Herder, M.; Schleberger, M.; Wucher, A. [Fakultät für Physik, Universität Duisburg-Essen and Cenide, 47057 Duisburg (Germany); Bender, M.; Severin, D. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt (Germany); Lebius, H. [CIMAP (CEA-CNRS-ENSICAEN-UCN), 14070 Caen Cedex 5 (France)

    2016-01-15

    The irradiation with fast ions with kinetic energies of >10 MeV leads to the deposition of a high amount of energy along their trajectory (up to several ten keV/nm). The energy is mainly transferred to the electronic subsystem and induces different secondary processes of excitations, which result in significant material modifications. A new setup to study these ion induced effects on surfaces will be described in this paper. The setup combines a variable irradiation chamber with different techniques of surface characterizations like scanning probe microscopy, time-of-flight secondary ion, and neutral mass spectrometry, as well as low energy electron diffraction under ultra high vacuum conditions, and is mounted at a beamline of the universal linear accelerator (UNILAC) of the GSI facility in Darmstadt, Germany. Here, samples can be irradiated with high-energy ions with a total kinetic energy up to several GeVs under different angles of incidence. Our setup enables the preparation and in situ analysis of different types of sample systems ranging from metals to insulators. Time-of-flight secondary ion mass spectrometry enables us to study the chemical composition of the surface, while scanning probe microscopy allows a detailed view into the local electrical and morphological conditions of the sample surface down to atomic scales. With the new setup, particle emission during irradiation as well as persistent modifications of the surface after irradiation can thus be studied. We present first data obtained with the new setup, including a novel measuring protocol for time-of-flight mass spectrometry with the GSI UNILAC accelerator.

  15. Production and Resource Scheduling in Mass Customization with Dependent Setup Consideration

    DEFF Research Database (Denmark)

    Nielsen, Izabela Ewa; Bocewicz, G.; Do, Ngoc Anh Dung

    2014-01-01

    will contribute to the success of mass customization. This paper addresses the problem of production and resource scheduling for a production system with dependent setup and internal transportation such as AGVs in a mass customization environment. A constraint-programming-based methodology is developed to satisfy...

  16. Development of group setup strategies for makespan minimization in PCB assembly

    DEFF Research Database (Denmark)

    Yilmaz, I.O.; Grunow, M.; Günther, H.-O.

    2007-01-01

    of the component magazine into account. We demonstrate the effectiveness of our approach in an extensive numerical investigation of a single-gantry collect-and-place machine equipped with a rotary placement head and an interchangeable feeder trolley. Compared to conventional methodologies, the proposed group setup...

  17. Identification of scleractinian coral recruits using fluorescent censusing and DNA barcoding techniques.

    Directory of Open Access Journals (Sweden)

    Chia-Min Hsu

    Full Text Available The identification of coral recruits has been problematic due to a lack of definitive morphological characters being available for higher taxonomic resolution. In this study, we tested whether fluorescent detection of coral recruits used in combinations of different DNA-barcoding markers (cytochrome oxidase I gene [COI], open reading frame [ORF], and nuclear Pax-C intron [PaxC] could be useful for increasing the resolution of coral spat identification in ecological studies. One hundred and fifty settlement plates were emplaced at nine sites on the fringing reefs of Kenting National Park in southern Taiwan between April 2011 and September 2012. A total of 248 living coral spats and juveniles (with basal areas ranging from 0.21 to 134.57 mm(2 were detected on the plates with the aid of fluorescent light and collected for molecular analyses. Using the COI DNA barcoding technique, 90.3% (224/248 of coral spats were successfully identified into six genera, including Acropora, Isopora, Montipora, Pocillopora, Porites, and Pavona. PaxC further separated I. cuneata and I. palifera of Isopora from Acropora, and ORF successfully identified the species of Pocillopora (except P. meandrina and P. eydouxi. Moreover, other cnidarian species such as actinarians, zoanthids, and Millepora species were visually found using fluorescence and identified by COI DNA barcoding. This combination of existing approaches greatly improved the taxonomic resolution of early coral life stages, which to date has been mainly limited to the family level based on skeletal identification. Overall, this study suggests important improvements for the identification of coral recruits in ecological studies.

  18. Identification of scleractinian coral recruits using fluorescent censusing and DNA barcoding techniques.

    Science.gov (United States)

    Hsu, Chia-Min; de Palmas, Stéphane; Kuo, Chao-Yang; Denis, Vianney; Chen, Chaolun Allen

    2014-01-01

    The identification of coral recruits has been problematic due to a lack of definitive morphological characters being available for higher taxonomic resolution. In this study, we tested whether fluorescent detection of coral recruits used in combinations of different DNA-barcoding markers (cytochrome oxidase I gene [COI], open reading frame [ORF], and nuclear Pax-C intron [PaxC]) could be useful for increasing the resolution of coral spat identification in ecological studies. One hundred and fifty settlement plates were emplaced at nine sites on the fringing reefs of Kenting National Park in southern Taiwan between April 2011 and September 2012. A total of 248 living coral spats and juveniles (with basal areas ranging from 0.21 to 134.57 mm(2)) were detected on the plates with the aid of fluorescent light and collected for molecular analyses. Using the COI DNA barcoding technique, 90.3% (224/248) of coral spats were successfully identified into six genera, including Acropora, Isopora, Montipora, Pocillopora, Porites, and Pavona. PaxC further separated I. cuneata and I. palifera of Isopora from Acropora, and ORF successfully identified the species of Pocillopora (except P. meandrina and P. eydouxi). Moreover, other cnidarian species such as actinarians, zoanthids, and Millepora species were visually found using fluorescence and identified by COI DNA barcoding. This combination of existing approaches greatly improved the taxonomic resolution of early coral life stages, which to date has been mainly limited to the family level based on skeletal identification. Overall, this study suggests important improvements for the identification of coral recruits in ecological studies.

  19. Experimental setup for x-ray absorption spectroscopy at the DESY

    International Nuclear Information System (INIS)

    Rabe, P.; Tolkiehn, G.; Werner, A.

    1979-10-01

    In this paper we describe an apparatus used at the Deutsches Elektronen-Synchrotron (DESY) for the measurement of x-ray absorption spectra, specially designed for the investigation of the extended x-ray absorption fine structure (EXAFS). Performance of the setup is discussed and compared with an apparatus using the bremsstrahlung of a conventional x-ray source. (orig.)

  20. Developing and implementing a high precision setup system

    Science.gov (United States)

    Peng, Lee-Cheng

    The demand for high-precision radiotherapy (HPRT) was first implemented in stereotactic radiosurgery using a rigid, invasive stereotactic head frame. Fractionated stereotactic radiotherapy (SRT) with a frameless device was developed along a growing interest in sophisticated treatment with a tight margin and high-dose gradient. This dissertation establishes the complete management for HPRT in the process of frameless SRT, including image-guided localization, immobilization, and dose evaluation. The most ideal and precise positioning system can allow for ease of relocation, real-time patient movement assessment, high accuracy, and no additional dose in daily use. A new image-guided stereotactic positioning system (IGSPS), the Align RT3C 3D surface camera system (ART, VisionRT), which combines 3D surface images and uses a real-time tracking technique, was developed to ensure accurate positioning at the first place. The uncertainties of current optical tracking system, which causes patient discomfort due to additional bite plates using the dental impression technique and external markers, are found. The accuracy and feasibility of ART is validated by comparisons with the optical tracking and cone-beam computed tomography (CBCT) systems. Additionally, an effective daily quality assurance (QA) program for the linear accelerator and multiple IGSPSs is the most important factor to ensure system performance in daily use. Currently, systematic errors from the phantom variety and long measurement time caused by switching phantoms were discovered. We investigated the use of a commercially available daily QA device to improve the efficiency and thoroughness. Reasonable action level has been established by considering dosimetric relevance and clinic flow. As for intricate treatments, the effect of dose deviation caused by setup errors remains uncertain on tumor coverage and toxicity on OARs. The lack of adequate dosimetric simulations based on the true treatment coordinates from

  1. Voice Quality Measuring Setup with Automatic Voice over IP Call Generator and Lawful Interception Packet Analyzer

    Directory of Open Access Journals (Sweden)

    PLEVA Matus

    Full Text Available This paper describes the packet measuring laboratory setup, which could be used also for lawful interception applications, using professional packet analyzer, Voice over IP call generator, free call server (Asterisk linux setup and appropriate software and hardware described below. This setup was used for measuring the quality of the automatically generated VoIP calls under stressed network conditions, when the call manager server was flooded with high bandwidth traffic, near the bandwidth limit of the connected switch. The call generator realizes 30 calls simultaneously and the packet capturer & analyzercould decode the VoIP traffic, extract RTP session data, automatically analyze the voice quality using standardized MOS (Mean Opinion Score values and describe also the source of the voice degradation (jitter, packet loss, codec, delay, etc..

  2. Verification of design calculations of a PGNAA setup using nuclear track ejectors

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. E-mail: aanaqvi@kfupm.edu.sa; Fazal-ur-Rehman,; Nagadi, .M.; Maslehuddin, M.; Khateeb-ur-Rehman; Kidwai, S

    2004-02-01

    A rectangular moderator assembly has been designed for the PGNAA setup at ing Fahd University of Petroleum and Minerals (KFUPM). The design calculations of the rectangular moderator, which were obtained through Monte Carlo simulation, have been verified experimentally through thermal neutron field measurement using CR-39 nuclear track detectors (NTDs). These measurements were carried out at the KFUPM 350 keV accelerator using 2.8 MeV pulsed neutron beam from D(d,n) reaction. The thermal neutron yield was measured inside the sample volume of the rectangular moderator by two NTDs fixed at back and front end of the sample cavity. The good agreement between he experimental results and the results of the calculations shows useful application of NTDs in verification of design calculations of a PGNAA setup.

  3. Extracranial stereotactic radiation therapy: set-up accuracy of patients treated for liver metastases

    International Nuclear Information System (INIS)

    Herfarth, K.K.; Debus, J.; Lohr, F.; Bahner, M.L.; Fritz, P.; Hoess, A.; Schlegel, W. Ph.D.; Wannenmacher, M.F.

    2000-01-01

    Purpose: Patients with liver metastases might benefit from high-dose conformal radiation therapy. A high accuracy of repositioning and a reduction of target movement are necessary for such an approach. The set-up accuracy of patients with liver metastases treated with stereotactic single dose radiation was evaluated. Methods and Materials: Twenty-four patients with liver metastases were treated with single dose radiation therapy on 26 occasions using a self-developed stereotactic frame. Liver movement was reduced by abdominal pressure. The effectiveness was evaluated under fluoroscopy. CT scans were performed on the planning day and directly before treatment. Representative reference marks were chosen and the coordinates were calculated. In addition, the target displacement was quantitatively evaluated after treatment. Results: Diaphragmal movement was reduced to median 7 mm (range: 3-13 mm). The final set-up accuracy of the body was limited to all of median 1.8 mm in latero-lateral direction (range: 0.3-5.0 mm) and 2.0 mm in anterior-posterior direction (0.8-3.8 mm). Deviations of the body in cranio-caudal direction were always less than the thickness of one CT slice (<5 mm). However, a repositioning was necessary in 16 occasions. The final target shift was median 1.6 mm (0.2-7.0 mm) in latero-lateral and 2.3 mm in anterior-posterior direction (0.0-6.3 mm). The median shift in cranio-caudal direction was 4.4 mm (0.0-10.0 mm). Conclusions: In patients with liver metastases, a high set-up accuracy of the body and the target can be achieved. This allows a high-dose focal radiotherapy of these lesions. However, a control CT scan should be performed directly before therapy to confirm set-up accuracy and possibly prompt necessary corrections

  4. Residual setup errors caused by rotation and non-rigid motion in prone-treated cervical cancer patients after online CBCT image-guidance

    International Nuclear Information System (INIS)

    Ahmad, Rozilawati; Hoogeman, Mischa S.; Quint, Sandra; Mens, Jan Willem; Osorio, Eliana M. Vásquez; Heijmen, Ben J.M.

    2012-01-01

    Purpose: To quantify the impact of uncorrected or partially corrected pelvis rotation and spine bending on region-specific residual setup errors in prone-treated cervical cancer patients. Methods and materials: Fifteen patients received an in-room CBCT scan twice a week. CBCT scans were registered to the planning CT-scan using a pelvic clip box and considering both translations and rotations. For daily correction of the detected translational pelvis setup errors by couch shifts, residual setup errors were determined for L5, L4 and seven other points of interest (POIs). The same was done for a procedure with translational corrections and limited rotational correction (±3°) by a 6D positioning device. Results: With translational correction only, residual setup errors were large especially for L5/L4 in AP direction (Σ = 5.1/5.5 mm). For the 7 POIs the residual setup errors ranged from 1.8 to 5.6 mm (AP). Using the 6D positioning device, the errors were substantially smaller (for L5/L4 in AP direction Σ = 2.7/2.2 mm). Using this device, the percentage of fractions with a residual AP displacement for L4 > 5 mm reduced from 47% to 9%. Conclusions: Setup variations caused by pelvis rotations are large and cannot be ignored in prone treatment of cervical cancer patients. Corrections with a 6D positioning device may considerably reduce resulting setup errors, but the residual setup errors should still be accounted for by appropriate CTV-to-PTV margins.

  5. Focus stacking: Comparing commercial top-end set-ups with a semi-automatic low budget approach. A possible solution for mass digitization of type specimens.

    Science.gov (United States)

    Brecko, Jonathan; Mathys, Aurore; Dekoninck, Wouter; Leponce, Maurice; VandenSpiegel, Didier; Semal, Patrick

    2014-01-01

    In this manuscript we present a focus stacking system, composed of commercial photographic equipment. The system is inexpensive compared to high-end commercial focus stacking solutions. We tested this system and compared the results with several different software packages (CombineZP, Auto-Montage, Helicon Focus and Zerene Stacker). We tested our final stacked picture with a picture obtained from two high-end focus stacking solutions: a Leica MZ16A with DFC500 and a Leica Z6APO with DFC290. Zerene Stacker and Helicon Focus both provided satisfactory results. However, Zerene Stacker gives the user more possibilities in terms of control of the software, batch processing and retouching. The outcome of the test on high-end solutions demonstrates that our approach performs better in several ways. The resolution of the tested extended focus pictures is much higher than those from the Leica systems. The flash lighting inside the Ikea closet creates an evenly illuminated picture, without struggling with filters, diffusers, etc. The largest benefit is the price of the set-up which is approximately € 3,000, which is 8 and 10 times less than the LeicaZ6APO and LeicaMZ16A set-up respectively. Overall, this enables institutions to purchase multiple solutions or to start digitising the type collection on a large scale even with a small budget.

  6. Focus stacking: Comparing commercial top-end set-ups with a semi-automatic low budget approach. A possible solution for mass digitization of type specimens

    Directory of Open Access Journals (Sweden)

    Jonathan Brecko

    2014-12-01

    Full Text Available In this manuscript we present a focus stacking system, composed of commercial photographic equipment. The system is inexpensive compared to high-end commercial focus stacking solutions. We tested this system and compared the results with several different software packages (CombineZP, Auto-Montage, Helicon Focus and Zerene Stacker. We tested our final stacked picture with a picture obtained from two high-end focus stacking solutions: a Leica MZ16A with DFC500 and a Leica Z6APO with DFC290. Zerene Stacker and Helicon Focus both provided satisfactory results. However, Zerene Stacker gives the user more possibilities in terms of control of the software, batch processing and retouching. The outcome of the test on high-end solutions demonstrates that our approach performs better in several ways. The resolution of the tested extended focus pictures is much higher than those from the Leica systems. The flash lighting inside the Ikea closet creates an evenly illuminated picture, without struggling with filters, diffusers, etc. The largest benefit is the price of the set-up which is approximately € 3,000, which is 8 and 10 times less than the LeicaZ6APO and LeicaMZ16A set-up respectively. Overall, this enables institutions to purchase multiple solutions or to start digitising the type collection on a large scale even with a small budget.

  7. GPU-accelerated automatic identification of robust beam setups for proton and carbon-ion radiotherapy

    International Nuclear Information System (INIS)

    Ammazzalorso, F; Jelen, U; Bednarz, T

    2014-01-01

    We demonstrate acceleration on graphic processing units (GPU) of automatic identification of robust particle therapy beam setups, minimizing negative dosimetric effects of Bragg peak displacement caused by treatment-time patient positioning errors. Our particle therapy research toolkit, RobuR, was extended with OpenCL support and used to implement calculation on GPU of the Port Homogeneity Index, a metric scoring irradiation port robustness through analysis of tissue density patterns prior to dose optimization and computation. Results were benchmarked against an independent native CPU implementation. Numerical results were in agreement between the GPU implementation and native CPU implementation. For 10 skull base cases, the GPU-accelerated implementation was employed to select beam setups for proton and carbon ion treatment plans, which proved to be dosimetrically robust, when recomputed in presence of various simulated positioning errors. From the point of view of performance, average running time on the GPU decreased by at least one order of magnitude compared to the CPU, rendering the GPU-accelerated analysis a feasible step in a clinical treatment planning interactive session. In conclusion, selection of robust particle therapy beam setups can be effectively accelerated on a GPU and become an unintrusive part of the particle therapy treatment planning workflow. Additionally, the speed gain opens new usage scenarios, like interactive analysis manipulation (e.g. constraining of some setup) and re-execution. Finally, through OpenCL portable parallelism, the new implementation is suitable also for CPU-only use, taking advantage of multiple cores, and can potentially exploit types of accelerators other than GPUs.

  8. GPU-accelerated automatic identification of robust beam setups for proton and carbon-ion radiotherapy

    Science.gov (United States)

    Ammazzalorso, F.; Bednarz, T.; Jelen, U.

    2014-03-01

    We demonstrate acceleration on graphic processing units (GPU) of automatic identification of robust particle therapy beam setups, minimizing negative dosimetric effects of Bragg peak displacement caused by treatment-time patient positioning errors. Our particle therapy research toolkit, RobuR, was extended with OpenCL support and used to implement calculation on GPU of the Port Homogeneity Index, a metric scoring irradiation port robustness through analysis of tissue density patterns prior to dose optimization and computation. Results were benchmarked against an independent native CPU implementation. Numerical results were in agreement between the GPU implementation and native CPU implementation. For 10 skull base cases, the GPU-accelerated implementation was employed to select beam setups for proton and carbon ion treatment plans, which proved to be dosimetrically robust, when recomputed in presence of various simulated positioning errors. From the point of view of performance, average running time on the GPU decreased by at least one order of magnitude compared to the CPU, rendering the GPU-accelerated analysis a feasible step in a clinical treatment planning interactive session. In conclusion, selection of robust particle therapy beam setups can be effectively accelerated on a GPU and become an unintrusive part of the particle therapy treatment planning workflow. Additionally, the speed gain opens new usage scenarios, like interactive analysis manipulation (e.g. constraining of some setup) and re-execution. Finally, through OpenCL portable parallelism, the new implementation is suitable also for CPU-only use, taking advantage of multiple cores, and can potentially exploit types of accelerators other than GPUs.

  9. Setup reproducibility in radiation therapy for lung cancer: a comparison between T-bar and expanded foam immobilization devices

    International Nuclear Information System (INIS)

    Halperin, Ross; Roa, Wilson; Field, Melissa; Hanson, John; Murray, Brad

    1999-01-01

    Purpose: Physiologic and non-physiologic tumor motion complicates the use of tight margins in three-dimensional (3D) conformal radiotherapy. Setup reproducibility is an important non-physiologic cause of tumor motion. The objective of this study is to evaluate and compare patient setup reproducibility using the reusable T-bar and the disposable expanded foam immobilization device (EFID) in radiation therapy for lung cancer. Methods and Materials: Two hundred forty-four portal films were taken from 16 prospectively accrued patients treated for lung cancer. Patients were treated with either a pair of anterior and posterior parallel opposing fields (POF), or a combination of POF and a three-field isocentric technique. Each patient was treated in a supine position using either the T-bar setup or EFID. Six patients were treated in both devices over their treatment courses. Field placement analysis was used to evaluate 3D setup reproducibility, by comparing positions of bony landmarks relative to the radiation field edges in digitized simulator and portal images. Anterior-posterior, lateral, and longitudinal displacements, as well as field rotations along coronal and sagittal planes were measured. Statistical analyses of variance were applied to the deviations among portal films of all patients and the subgroup treated with both immobilization methods. Results: For the T-bar immobilization device, standard deviations of the setup reproducibility were 5.1, 3.7, and 5.1 mm in the anterior-posterior, lateral, and longitudinal dimensions, respectively. Rotations in the coronal plane and the sagittal plane were 0.9 deg. and 1.0 deg. , respectively. For the EFID, corresponding standard deviations of set up reproducibility were 3.6 mm, 5.3 mm, 5.4 mm, 0.7 deg. and 1.4 deg. , respectively. There was no statistically significant difference (p = 0.22) in the 3D setup reproducibility between T-bar and EFID. Subgroup analysis for the patients who were treated with both

  10. Investigation on Superior Performance by Fractional Controller for Cart-Servo Laboratory Set-Up

    Directory of Open Access Journals (Sweden)

    Ameya Anil Kesarkar

    2014-01-01

    Full Text Available In this paper, an investigation is made on the superiority of fractional PID controller (PI^alpha D^beta over conventional PID for the cart-servo laboratory set-up. The designed controllers are optimum in the sense of Integral Absolute Error (IAE and Integral Square Error (ISE. The paper contributes in three aspects: 1 Acquiring nonlinear mathematical model for the cart-servo laboratory set-up, 2 Designing fractional and integer order PID for minimizing IAE, ISE, 3 Analyzing the performance of designed controllers for simulated plant model as well as real plant. The results show a significantly superior performance by PI^alpha D^beta as compared to the conventional PID controller.

  11. Development of a TOF SIMS setup at the Zagreb heavy ion microbeam facility

    Science.gov (United States)

    Tadić, Tonči; Bogdanović Radović, Iva; Siketić, Zdravko; Cosic, Donny Domagoj; Skukan, Natko; Jakšić, Milko; Matsuo, Jiro

    2014-08-01

    We describe a new Time-of-flight Secondary Ion Mass Spectrometry (TOF SIMS) setup for MeV SIMS application, which is constructed and installed at the heavy ion microbeam facility at the Ruđer Bošković Institute in Zagreb. The TOF-SIMS setup is developed for high sensitivity molecular imaging using a heavy ion microbeam that focuses ion beams (from C to I) with sub-micron resolution. Dedicated pulse processing electronics for MeV SIMS application have been developed, enabling microbeam-scanning control, incoming ion microbeam pulsing and molecular mapping. The first results showing measured MeV SIMS spectra as well as molecular maps for samples of interest are presented and discussed.

  12. Development of a TOF SIMS setup at the Zagreb heavy ion microbeam facility

    International Nuclear Information System (INIS)

    Tadić, Tonči; Bogdanović Radović, Iva; Siketić, Zdravko; Cosic, Donny Domagoj; Skukan, Natko; Jakšić, Milko; Matsuo, Jiro

    2014-01-01

    We describe a new Time-of-flight Secondary Ion Mass Spectrometry (TOF SIMS) setup for MeV SIMS application, which is constructed and installed at the heavy ion microbeam facility at the Ruđer Bošković Institute in Zagreb. The TOF-SIMS setup is developed for high sensitivity molecular imaging using a heavy ion microbeam that focuses ion beams (from C to I) with sub-micron resolution. Dedicated pulse processing electronics for MeV SIMS application have been developed, enabling microbeam-scanning control, incoming ion microbeam pulsing and molecular mapping. The first results showing measured MeV SIMS spectra as well as molecular maps for samples of interest are presented and discussed

  13. Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy

    International Nuclear Information System (INIS)

    Shirato, Hiroki; Suzuki, Keishiro; Sharp, Gregory C.; Fujita, Katsuhisa R.T.; Onimaru, Rikiya; Fujino, Masaharu; Kato, Norio; Osaka, Yasuhiro; Kinoshita, Rumiko; Taguchi, Hiroshi; Onodera, Shunsuke; Miyasaka, Kazuo

    2006-01-01

    Background: To reduce the uncertainty of registration for lung tumors, we have developed a four-dimensional (4D) setup system using a real-time tumor-tracking radiotherapy system. Methods and Materials: During treatment planning and daily setup in the treatment room, the trajectory of the internal fiducial marker was recorded for 1 to 2 min at the rate of 30 times per second by the real-time tumor-tracking radiotherapy system. To maximize gating efficiency, the patient's position on the treatment couch was adjusted using the 4D setup system with fine on-line remote control of the treatment couch. Results: The trajectory of the marker detected in the 4D setup system was well visualized and used for daily setup. Various degrees of interfractional and intrafractional changes in the absolute amplitude and speed of the internal marker were detected. Readjustments were necessary during each treatment session, prompted by baseline shifting of the tumor position. Conclusion: The 4D setup system was shown to be useful for reducing the uncertainty of tumor motion and for increasing the efficiency of gated irradiation. Considering the interfractional and intrafractional changes in speed and amplitude detected in this study, intercepting radiotherapy is the safe and cost-effective method for 4D radiotherapy using real-time tracking technology

  14. Six dimensional X-ray Tensor Tomography with a compact laboratory setup

    Science.gov (United States)

    Sharma, Y.; Wieczorek, M.; Schaff, F.; Seyyedi, S.; Prade, F.; Pfeiffer, F.; Lasser, T.

    2016-09-01

    Attenuation based X-ray micro computed tomography (XCT) provides three-dimensional images with micrometer resolution. However, there is a trade-off between the smallest size of the structures that can be resolved and the measurable sample size. In this letter, we present an imaging method using a compact laboratory setup that reveals information about micrometer-sized structures within samples that are several orders of magnitudes larger. We combine the anisotropic dark-field signal obtained in a grating interferometer and advanced tomographic reconstruction methods to reconstruct a six dimensional scattering tensor at every spatial location in three dimensions. The scattering tensor, thus obtained, encodes information about the orientation of micron-sized structures such as fibres in composite materials or dentinal tubules in human teeth. The sparse acquisition schemes presented in this letter enable the measurement of the full scattering tensor at every spatial location and can be easily incorporated in a practical, commercially feasible laboratory setup using conventional X-ray tubes, thus allowing for widespread industrial applications.

  15. Performance of velocity vector estimation using an improved dynamic beamforming setup

    DEFF Research Database (Denmark)

    Munk, Peter; Jensen, Jørgen Arendt

    2001-01-01

    control of the acoustic field, based on the Pulsed Plane Wave Decomposition (PPWD), is presented. The PPWD gives an unambigious relation between a given acoustic field and the time functions needed on an array transducer for transmission. Applying this method for the receive beamformation results in a set...... and experimental data. The simulation setup is an attempt to approximate the situation present when performing a scanning of the carotid artery with a linear array. Measurement of the flow perpendicular to the emission direction is possible using the approach of transverse spatial modulation. This is most often...... the case in a scanning of the carotid artery, where the situation is handled by an angled Doppler setup in the present ultrasound scanners. The modulation period of 2 mm is controlled for a range of 20-40 mm which covers the typical range of the carotid artery. A 6 MHz array on a 128-channel system...

  16. A containerless levitation setup for liquid processing in a superconducting magnet.

    Science.gov (United States)

    Lu, Hui-Meng; Yin, Da-Chuan; Li, Hai-Sheng; Geng, Li-Qiang; Zhang, Chen-Yan; Lu, Qin-Qin; Guo, Yun-Zhu; Guo, Wei-Hong; Shang, Peng; Wakayama, Nobuko I

    2008-09-01

    Containerless processing of materials is considered beneficial for obtaining high quality products due to the elimination of the detrimental effects coming from the contact with container walls. Many containerless processing methods are realized by levitation techniques. This paper describes a containerless levitation setup that utilized the magnetization force generated in a gradient magnetic field. It comprises a levitation unit, a temperature control unit, and a real-time observation unit. Known volume of liquid diamagnetic samples can be levitated in the levitation chamber, the temperature of which is controlled using the temperature control unit. The evolution of the levitated sample is observed in real time using the observation unit. With this setup, containerless processing of liquid such as crystal growth from solution can be realized in a well-controlled manner. Since the levitation is achieved using a superconducting magnet, experiments requiring long duration time such as protein crystallization and simulation of space environment for living system can be easily succeeded.

  17. Experimental setup for evaluating an adaptive user interface for teleoperation control

    Science.gov (United States)

    Wijayasinghe, Indika B.; Peetha, Srikanth; Abubakar, Shamsudeen; Saadatzi, Mohammad Nasser; Cremer, Sven; Popa, Dan O.

    2017-05-01

    A vital part of human interactions with a machine is the control interface, which single-handedly could define the user satisfaction and the efficiency of performing a task. This paper elaborates the implementation of an experimental setup to study an adaptive algorithm that can help the user better tele-operate the robot. The formulation of the adaptive interface and associate learning algorithms are general enough to apply when the mapping between the user controls and the robot actuators is complex and/or ambiguous. The method uses a genetic algorithm to find the optimal parameters that produce the input-output mapping for teleoperation control. In this paper, we describe the experimental setup and associated results that was used to validate the adaptive interface to a differential drive robot from two different input devices; a joystick, and a Myo gesture control armband. Results show that after the learning phase, the interface converges to an intuitive mapping that can help even inexperienced users drive the system to a goal location.

  18. Process control for the Vivitron: the generator test set-up

    International Nuclear Information System (INIS)

    Lutz, J.R.; Marsaudon, J.C.; Baumann, R.; Kapps, E.; Knaebel, R.; Persigny, J.

    1992-01-01

    The VIVITRON is a 35 MV Van de Graaff tandem electrostatic accelerator under construction at the CRN since 1985. About half of the parameters are controlled by equipments which are highly stressed by their physical environment: sparks, electrostatic field, X-rays, vacuum, and gas pressure. It needs a dedicated process control system. The described control system is used since early 1991 to perform the voltage tests of the generator. It provides important information for the accelerator tuning and for the full size control under development. (author)

  19. Pixel-Tilecal-MDT Combined Test Beam

    CERN Multimedia

    B. Di Girolamo

    A test with many expectations When an additional week of running (from September 11th to 18th) was allocated for the test-beam, it was decided to give priority to a combined run with the participation of the Pixel, Tilecal and MDT sub-detectors. The integration of these three sub-detectors was possible as they all use the baseline (DAQ-1/EF based) DAQ for test beams (as reported in a previous e-news). The tests and the addition of a common trigger and busy were organized in a short timescale by experts from the three sub-detectors and DAQ/EF. The expectations were many; both looking for problems and finding solutions. The setup The setup, shown in the figure, consisted of the Pixel telescope normally used during the sub-detector tests, two Tilecal barrel modules, two Tilecal extended barrel modules, and six MDT barrel chambers. This fully occupied a length of some 30 meters in the H8 line of the SPS North Area. Each sub-detector used their own specialized front-end electronics. The data collected by modu...

  20. Automatic test system of the photomultipliers

    International Nuclear Information System (INIS)

    Shiino, Kazuo; Kono, Koji; Ishii, Takanobu; Kasai, Seiji; Yamada, Sakue; Kitamura, Shoichi.

    1990-03-01

    A test system of R580 photomultipliers (PMTs) was constructed for the ZEUS experiment HERA. In this report, we will describe the general feature of the test system, each component of the setup, the procedure of the measurements, the data analyses and the results of the first 800 PMT measurements. (author)

  1. Validation of a fully automated robotic setup for preparation of whole blood samples for LC-MS toxicology analysis

    DEFF Research Database (Denmark)

    Andersen, David Wederkinck; Rasmussen, Brian; Linnet, Kristian

    2012-01-01

    A fully automated setup was developed for preparing whole blood samples using a Tecan Evo workstation. By integrating several add-ons to the robotic platform, the flexible setup was able to prepare samples from sample tubes to a 96-well sample plate ready for injection on liquid chromatography...

  2. Laser-assisted chemical vapor deposition setup for fast synthesis of graphene patterns

    Science.gov (United States)

    Zhang, Chentao; Zhang, Jianhuan; Lin, Kun; Huang, Yuanqing

    2017-05-01

    An automatic setup based on the laser-assisted chemical vapor deposition method has been developed for the rapid synthesis of graphene patterns. The key components of this setup include a laser beam control and focusing unit, a laser spot monitoring unit, and a vacuum and flow control unit. A laser beam with precision control of laser power is focused on the surface of a nickel foil substrate by the laser beam control and focusing unit for localized heating. A rapid heating and cooling process at the localized region is induced by the relative movement between the focalized laser spot and the nickel foil substrate, which causes the decomposing of gaseous hydrocarbon and the out-diffusing of excess carbon atoms to form graphene patterns on the laser scanning path. All the fabrication parameters that affect the quality and number of graphene layers, such as laser power, laser spot size, laser scanning speed, pressure of vacuum chamber, and flow rates of gases, can be precisely controlled and monitored during the preparation of graphene patterns. A simulation of temperature distribution was carried out via the finite element method, providing a scientific guidance for the regulation of temperature distribution during experiments. A multi-layer graphene ribbon with few defects was synthesized to verify its performance of the rapid growth of high-quality graphene patterns. Furthermore, this setup has potential applications in other laser-based graphene synthesis and processing.

  3. A simple and convenient set-up for high-temperature Brillouin light scattering

    International Nuclear Information System (INIS)

    Guerette, Michael; Huang Liping

    2012-01-01

    An emulated platelet geometry (or reflection-induced platelet geometry) is employed to collect photons scattered from both longitudinal and transverse acoustic waves travelling within a bulk transparent sample sitting on a reflective Pt plate. Temperature of the sample was controlled with a Linkam TS1500 optical furnace (maximum temperature of 1500 °C). This simple and convenient set-up allows a full determination of elastic constants of transparent materials in situ as a function of temperature from Brillouin light scattering. Structural information can be gained at the same time by guiding the scattered light into a Raman spectrometer using a flipping mirror or a beam splitter. We will demonstrate the applications of this set-up in transparent inorganic glasses, but it can be easily extended to any other transparent materials, either crystalline or amorphous in nature. (paper)

  4. Cost Effective Cloud Environment Setup to Secure Corporate Data

    OpenAIRE

    Mrs.Ashwini Prakash Sawant; Prof. Sandeep Vanjale; Mrs. Mousami Vanjale

    2013-01-01

    In recent years ad-hoc parallel processing has emerged to be one among the killer applications for Infrastructure-as-a-Service (IaaS) clouds. Major Cloud computing firms have began to integrate frameworks for parallel processing in their product portfolio, creating it simple for purchasers to access these services and to deploy their programs. However, the process frameworks that area unit presently used are designed for static, consistent cluster setups and disrespect the actual nature of a ...

  5. The role of a prone setup in breast radiation therapy.

    Science.gov (United States)

    Huppert, Nelly; Jozsef, Gabor; Dewyngaert, Keith; Formenti, Silvia Chiara

    2011-01-01

    Most patients undergoing breast conservation therapy receive radiotherapy in the supine position. Historically, prone breast irradiation has been advocated for women with large pendulous breasts in order to decrease acute and late toxicities. With the advent of CT planning, the prone technique has become both feasible and reproducible. It was shown to be advantageous not only for women with larger breasts but in most patients since it consistently reduces, if not eliminates, the inclusion of heart and lung within the field. The prone setup has been accepted as the best localizing position for both MRI and stereotactic biopsy, but its adoption has been delayed in radiotherapy. New technological advances including image-modulated radiation therapy and image-guided radiation therapy have made possible the exploration of accelerated fractionation schemes with a concomitant boost to the tumor bed in the prone position, along with better imaging and verification of reproducibility of patient setup. This review describes some of the available techniques for prone breast radiotherapy and the available experience in their application. The NYU prone breast radiotherapy approach is discussed, including a summary of the results from several prospective trials.

  6. The role of a prone setup in breast radiation therapy

    Directory of Open Access Journals (Sweden)

    Nelly eHuppert

    2011-10-01

    Full Text Available Most patients undergoing breast conservation therapy (BCT receive radiotherapy in the supine position. Historically, prone breast irradiation has been advocated for women with large pendulous breasts in order to decrease acute and late toxicities. With the advent of CT planning, the prone technique has become both feasible and reproducible. It was shown to be advantageous not only for women with larger breasts but in most patients since it consistently reduces, if not eliminates, the inclusion of heart and lung within the field. The prone setup has been accepted as the best localizing position for both MRI and stereotactic biopsy, but its adoption has been delayed in radiotherapy. New technological advances including image-modulated radiation therapy (IMRT and image-guided radiation therapy (IGRT have made possible the exploration of accelerated fractionation schemes with a concomitant boost to the tumor bed in the prone position, along with better imaging and verification of reproducibility of patient setup. This review describes some of the available techniques for prone breast radiotherapy and the available experience in their application. The NYU prone breast radiotherapy approach is discussed, including a summary of the results from several prospective trials.

  7. The Role of a Prone Setup in Breast Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Huppert, Nelly; Jozsef, Gabor; DeWyngaert, Keith; Formenti, Silvia Chiara, E-mail: silvia.formenti@nyumc.org [Department of Radiation Oncology, New York University School of Medicine, New York University Langone Medical Center, New York, NY (United States)

    2011-10-11

    Most patients undergoing breast conservation therapy receive radiotherapy in the supine position. Historically, prone breast irradiation has been advocated for women with large pendulous breasts in order to decrease acute and late toxicities. With the advent of CT planning, the prone technique has become both feasible and reproducible. It was shown to be advantageous not only for women with larger breasts but in most patients since it consistently reduces, if not eliminates, the inclusion of heart and lung within the field. The prone setup has been accepted as the best localizing position for both MRI and stereotactic biopsy, but its adoption has been delayed in radiotherapy. New technological advances including image-modulated radiation therapy and image-guided radiation therapy have made possible the exploration of accelerated fractionation schemes with a concomitant boost to the tumor bed in the prone position, along with better imaging and verification of reproducibility of patient setup. This review describes some of the available techniques for prone breast radiotherapy and the available experience in their application. The NYU prone breast radiotherapy approach is discussed, including a summary of the results from several prospective trials.

  8. Comparison of different Bremsstrahlung converters and collimators for Nuclear Resonance Fluorescence setup at IFUSP

    International Nuclear Information System (INIS)

    Lopez, P.N; Corrales, Y.; Manso Guevara, M.V; Martins, M.N.

    2007-01-01

    Nuclear Resonance Fluorescence (NRF) setup will install in the new electron accelerator, which is in final stage of installation at the Physics Institute of Sao Paulo University (IFUSP). The Bremsstrahlung facility and the setup for photon scattering should be designed such that the background radiation caused by scattering photons and the production of neutrons is minimized. In this order the Monte Carlo simulation studies show the best options for the different elements of the NRF setup, and how to link these elements to the particularities of the irradiation room. In the present stage the simulations has been included the studies of different Bremsstrahlung converters and collimators. Several materials (Ta, W, Au, Nb, Cu) for Bremsstrahlung converters were studied. Detailed analyses of intensity as well as the opening angles of Bremsstrahlung radiation were carried out, for different converter thickness. For the collimator two materials (Cu and Pb) were studied in the simulations. Several opening angles and thickness (40 - 100 cm) were studied. The Bremsstrahlung beam collimation for different energy bins, and the photon scattering from the collimator ,were used as quality parameters of the collimators. (Author)

  9. Genetic evolutionary taboo search for optimal marker placement in infrared patient setup

    International Nuclear Information System (INIS)

    Riboldi, M; Baroni, G; Spadea, M F; Tagaste, B; Garibaldi, C; Cambria, R; Orecchia, R; Pedotti, A

    2007-01-01

    In infrared patient setup adequate selection of the external fiducial configuration is required for compensating inner target displacements (target registration error, TRE). Genetic algorithms (GA) and taboo search (TS) were applied in a newly designed approach to optimal marker placement: the genetic evolutionary taboo search (GETS) algorithm. In the GETS paradigm, multiple solutions are simultaneously tested in a stochastic evolutionary scheme, where taboo-based decision making and adaptive memory guide the optimization process. The GETS algorithm was tested on a group of ten prostate patients, to be compared to standard optimization and to randomly selected configurations. The changes in the optimal marker configuration, when TRE is minimized for OARs, were specifically examined. Optimal GETS configurations ensured a 26.5% mean decrease in the TRE value, versus 19.4% for conventional quasi-Newton optimization. Common features in GETS marker configurations were highlighted in the dataset of ten patients, even when multiple runs of the stochastic algorithm were performed. Including OARs in TRE minimization did not considerably affect the spatial distribution of GETS marker configurations. In conclusion, the GETS algorithm proved to be highly effective in solving the optimal marker placement problem. Further work is needed to embed site-specific deformation models in the optimization process

  10. Physical separations soil washing system cold test results

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, J.P.

    1993-07-28

    This test summary describes the objectives, methodology, and results of a physical separations soil-washing system setup and shakedown test using uncontaminated soil. The test is being conducted in preparation for a treatability test to be conducted in the North Pond of the 300-FF-1 Operable Unit. It will be used to assess the feasibility of using a physical separations process to reduce the volume of contaminated soils in the 300-FF-1 Operable Unit. The test is described in DOE-RL (1993). The setup test was conducted at an uncontrolled area located approximately 3.2 km northwest of the 300-FF-1 Operable Unit. The material processed was free of contamination. The physical separation equipment to be used in the test was transferred to the US Department of Energy (DOE) by the US Environmental Protection Agency (EPA) Risk Reduction Engineering Laboratory. On May 13, 1993, soil-washing equipment was moved to the cold test location. Design assistance and recommendation for operation was provided by the EPA.

  11. Integrating sphere-based setup as an accurate system for optical properties measurements

    CSIR Research Space (South Africa)

    Abdalmonem, S

    2010-09-01

    Full Text Available Determination of the optical properties of solid and liquid samples has great importance. Since the integrating sphere-based setup is used to measure the amount of reflected and transmitted light by the examined samples, optical properties could...

  12. Measurement setup for the magnetic penetration depth and superfluid stiffness in thin superconducting films

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, Lorenz; Brunner, Markus Christopher Paul; Schneider, Ina; Kronfeldner, Klaus; Strunk, Christoph [Institute for exp. and appl. Physics, University of Regensburg (Germany); Bousquet, Jessica; Bustarret, Etienne [Institut NEEL, Grenoble (France)

    2015-07-01

    A mutual inductance measurement setup has been established in order to determine the magnetic penetration depths of thin film superconductors. By measuring the variation of the mutual inductance M, the temperature dependent penetration depth can be evaluated. The setup has been characterized using thin aluminum and niobium films as a reference. Temperature dependence of λ of B-doped diamond films is determined down to 0.3 K and compared with theoretical expectations. The impact of the doping ratio B/C and film thickness on λ and T{sub c} is investigated. Correlation between the film impedance σ = σ{sub 1} - i σ{sub 2} and λ is examined.

  13. The research of knitting needle status monitoring setup

    Science.gov (United States)

    Liu, Lu; Liao, Xiao-qing; Zhu, Yong-kang; Yang, Wei; Zhang, Pei; Zhao, Yong-kai; Huang, Hui-jie

    2013-09-01

    In textile production, quality control and testing is the key to ensure the process and improve the efficiency. Defect of the knitting needles is the main factor affecting the quality of the appearance of textiles. Defect detection method based on machine vision and image processing technology is universal. This approach does not effectively identify the defect generated by damaged knitting needles and raise the alarm. We developed a knitting needle status monitoring setup using optical imaging, photoelectric detection and weak signal processing technology to achieve real-time monitoring of weaving needles' position. Depending on the shape of the knitting needle, we designed a kind of Glass Optical Fiber (GOF) light guides with a rectangular port used for transmission of the signal light. To be able to capture the signal of knitting needles accurately, we adopt a optical 4F system which has better imaging quality and simple structure and there is a rectangle image on the focal plane after the system. When a knitting needle passes through position of the rectangle image, the reflected light from needle surface will back to the GOF light guides along the same optical system. According to the intensity of signals, the computer control unit distinguish that the knitting needle is broken or curving. The experimental results show that this system can accurately detect the broken needles and the curving needles on the knitting machine in operating condition.

  14. Evaluation of initial setup errors of two immobilization devices for lung stereotactic body radiation therapy (SBRT).

    Science.gov (United States)

    Ueda, Yoshihiro; Teshima, Teruki; Cárdenes, Higinia; Das, Indra J

    2017-07-01

    The aim of this study was to investigate the accuracy and efficacy of two commonly used commercial immobilization systems for stereotactic body radiation therapy (SBRT) in lung cancer. This retrospective study assessed the efficacy and setup accuracy of two immobilization systems: the Elekta Body Frame (EBF) and the Civco Body Pro-Lok (CBP) in 80 patients evenly divided for each system. A cone beam CT (CBCT) was used before each treatment fraction for setup correction in both devices. Analyzed shifts were applied for setup correction and CBCT was repeated. If a large shift (>5 mm) occurred in any direction, an additional CBCT was employed for verification after localization. The efficacy of patient setup was analyzed for 105 sessions (48 with the EBF, 57 with the CBP). Result indicates that the CBCT was repeated at the 1 st treatment session in 22.5% and 47.5% of the EBF and CBP cases, respectively. The systematic errors {left-right (LR), anterior-posterior (AP), cranio-caudal (CC), and 3D vector shift: (LR 2 + AP 2 + CC 2 ) 1/2 (mm)}, were {0.5 ± 3.7, 2.3 ± 2.5, 0.7 ± 3.5, 7.1 ± 3.1} mm and {0.4 ± 3.6, 0.7 ± 4.0, 0.0 ± 5.5, 9.2 ± 4.2} mm, and the random setup errors were {5.1, 3.0, 3.5, 3.9} mm and {4.6, 4.8, 5.4, 5.3} mm for the EBF and the CBP, respectively. The 3D vector shift was significantly larger for the CBP (P patient comfort could dictate the use of CBP system with slightly reduced accuracy. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  15. Diffusing-wave spectroscopy in a standard dynamic light scattering setup

    Science.gov (United States)

    Fahimi, Zahra; Aangenendt, Frank J.; Voudouris, Panayiotis; Mattsson, Johan; Wyss, Hans M.

    2017-12-01

    Diffusing-wave spectroscopy (DWS) extends dynamic light scattering measurements to samples with strong multiple scattering. DWS treats the transport of photons through turbid samples as a diffusion process, thereby making it possible to extract the dynamics of scatterers from measured correlation functions. The analysis of DWS data requires knowledge of the path length distribution of photons traveling through the sample. While for flat sample cells this path length distribution can be readily calculated and expressed in analytical form; no such expression is available for cylindrical sample cells. DWS measurements have therefore typically relied on dedicated setups that use flat sample cells. Here we show how DWS measurements, in particular DWS-based microrheology measurements, can be performed in standard dynamic light scattering setups that use cylindrical sample cells. To do so we perform simple random-walk simulations that yield numerical predictions of the path length distribution as a function of both the transport mean free path and the detection angle. This information is used in experiments to extract the mean-square displacement of tracer particles in the material, as well as the corresponding frequency-dependent viscoelastic response. An important advantage of our approach is that by performing measurements at different detection angles, the average path length through the sample can be varied. For measurements performed on a single sample cell, this gives access to a wider range of length and time scales than obtained in a conventional DWS setup. Such angle-dependent measurements also offer an important consistency check, as for all detection angles the DWS analysis should yield the same tracer dynamics, even though the respective path length distributions are very different. We validate our approach by performing measurements both on aqueous suspensions of tracer particles and on solidlike gelatin samples, for which we find our DWS-based microrheology

  16. Analysis of Daily Setup Variation With Tomotherapy Megavoltage Computed Tomography

    International Nuclear Information System (INIS)

    Zhou Jining; Uhl, Barry; Dewit, Kelly; Young, Mark; Taylor, Brian; Fei Dingyu; Lo, Y-C

    2010-01-01

    The purpose of this study was to evaluate different setup uncertainties for various anatomic sites with TomoTherapy (registered) pretreatment megavoltage computed tomography (MVCT) and to provide optimal margin guidelines for these anatomic sites. Ninety-two patients with tumors in head and neck (HN), brain, lung, abdominal, or prostate regions were included in the study. MVCT was used to verify patient position and tumor target localization before each treatment. With the anatomy registration tool, MVCT provided real-time tumor shift coordinates relative to the positions where the simulation CT was performed. Thermoplastic facemasks were used for HN and brain treatments. Vac-Lok TM cushions were used to immobilize the lower extremities up to the thighs for prostate patients. No respiration suppression was administered for lung and abdomen patients. The interfractional setup variations were recorded and corrected before treatment. The mean interfractional setup error was the smallest for HN among the 5 sites analyzed. The average 3D displacement in lateral, longitudinal, and vertical directions for the 5 sites ranged from 2.2-7.7 mm for HN and lung, respectively. The largest movement in the lung was 2.0 cm in the longitudinal direction, with a mean error of 6.0 mm and standard deviation of 4.8 mm. The mean interfractional rotation variation was small and ranged from 0.2-0.5 deg., with the standard deviation ranging from 0.7-0.9 deg. Internal organ displacement was also investigated with a posttreatment MVCT scan for HN, lung, abdomen, and prostate patients. The maximum 3D intrafractional displacement across all sites was less than 4.5 mm. The interfractional systematic errors and random errors were analyzed and the suggested margins for HN, brain, prostate, abdomen, and lung in the lateral, longitudinal, and vertical directions were between 4.2 and 8.2 mm, 5.0 mm and 12.0 mm, and 1.5 mm and 6.8 mm, respectively. We suggest that TomoTherapy (registered) pretreatment

  17. Analysis of daily setup variation with tomotherapy megavoltage computed tomography.

    Science.gov (United States)

    Zhou, Jining; Uhl, Barry; Dewit, Kelly; Young, Mark; Taylor, Brian; Fei, Ding-Yu; Lo, Yeh-Chi

    2010-01-01

    The purpose of this study was to evaluate different setup uncertainties for various anatomic sites with TomoTherapy pretreatment megavoltage computed tomography (MVCT) and to provide optimal margin guidelines for these anatomic sites. Ninety-two patients with tumors in head and neck (HN), brain, lung, abdominal, or prostate regions were included in the study. MVCT was used to verify patient position and tumor target localization before each treatment. With the anatomy registration tool, MVCT provided real-time tumor shift coordinates relative to the positions where the simulation CT was performed. Thermoplastic facemasks were used for HN and brain treatments. Vac-Lok cushions were used to immobilize the lower extremities up to the thighs for prostate patients. No respiration suppression was administered for lung and abdomen patients. The interfractional setup variations were recorded and corrected before treatment. The mean interfractional setup error was the smallest for HN among the 5 sites analyzed. The average 3D displacement in lateral, longitudinal, and vertical directions for the 5 sites ranged from 2.2-7.7 mm for HN and lung, respectively. The largest movement in the lung was 2.0 cm in the longitudinal direction, with a mean error of 6.0 mm and standard deviation of 4.8 mm. The mean interfractional rotation variation was small and ranged from 0.2-0.5 degrees, with the standard deviation ranging from 0.7-0.9 degrees. Internal organ displacement was also investigated with a posttreatment MVCT scan for HN, lung, abdomen, and prostate patients. The maximum 3D intrafractional displacement across all sites was less than 4.5 mm. The interfractional systematic errors and random errors were analyzed and the suggested margins for HN, brain, prostate, abdomen, and lung in the lateral, longitudinal, and vertical directions were between 4.2 and 8.2 mm, 5.0 mm and 12.0 mm, and 1.5 mm and 6.8 mm, respectively. We suggest that TomoTherapy pretreatment MVCT can be used to

  18. Comparison of different testing methods for gas fired domestic boiler efficiency determination

    International Nuclear Information System (INIS)

    De Paepe, M.; T'Joen, C.; Huisseune, H.; Van Belleghem, M.; Kessen, V.

    2013-01-01

    As the Energy Performance of Buildings Directive is being implemented throughout the European Union, a clear need for certification of boiler and domestic heating devices has arisen. Several ‘Notified Bodies’ exist, spread around the different member states. They are acting as the notified body of that member state and focus on local certification. A boiler manufacturer has its equipment tested according to the ‘Boiler Efficiency directive 92/42/EC’. Recently, tests done by several notified bodies in sequence on an identical unit of a manufacturer showed that results could differ depending on which notified body performed the test. In cooperation with ‘Technigas’ (Notified Body in Belgium) a detailed study was done of the measurement setup and devices for determining boiler efficiencies. Several aspects were studied: measurement devices (absolute or differential types), their location within the test setup (focussing on accuracy and their overall impact on the result) and the measurement strategy (measuring on the primary or the secondary water side). The study was performed for both full load and part load scenarios of a gas fired domestic boiler (smaller than 70 kW [4]). The results clearly indicate that temperature measurements arecritical for assessing boiler efficiency. Secondly the test setup using secondary circuit measurements should be preferred. Tests were performed at ‘Technigas’ on different setups in order to validate the findings. - Highlights: ► Labelling of boiler is now obliged by European standards. ► Error propagation is analysed for different methods of boiler performance testing. ► Secondary water side measurement with separate calibration of has highest quality. ► A sensitivity analysis showed that the water temperatures are important factors.

  19. A user-friendly technical set-up for infrared photography of forensic findings.

    Science.gov (United States)

    Rost, Thomas; Kalberer, Nicole; Scheurer, Eva

    2017-09-01

    Infrared photography is interesting for a use in forensic science and forensic medicine since it reveals findings that normally are almost invisible to the human eye. Originally, infrared photography has been made possible by the placement of an infrared light transmission filter screwed in front of the camera objective lens. However, this set-up is associated with many drawbacks such as the loss of the autofocus function, the need of an external infrared source, and long exposure times which make the use of a tripod necessary. These limitations prevented up to now the routine application of infrared photography in forensics. In this study the use of a professional modification inside the digital camera body was evaluated regarding camera handling and image quality. This permanent modification consisted of the replacement of the in-built infrared blocking filter by an infrared transmission filter of 700nm and 830nm, respectively. The application of this camera set-up for the photo-documentation of forensically relevant post-mortem findings was investigated in examples of trace evidence such as gunshot residues on the skin, in external findings, e.g. hematomas, as well as in an exemplary internal finding, i.e., Wischnewski spots in a putrefied stomach. The application of scattered light created by indirect flashlight yielded a more uniform illumination of the object, and the use of the 700nm filter resulted in better pictures than the 830nm filter. Compared to pictures taken under visible light, infrared photographs generally yielded better contrast. This allowed for discerning more details and revealed findings which were not visible otherwise, such as imprints on a fabric and tattoos in mummified skin. The permanent modification of a digital camera by building in a 700nm infrared transmission filter resulted in a user-friendly and efficient set-up which qualified for the use in daily forensic routine. Main advantages were a clear picture in the viewfinder, an auto

  20. Development of a low-level setup for gamma spectroscopy: Application for nuclear astrophysics using reverse kinematics

    International Nuclear Information System (INIS)

    Genard, G.; Nuttens, V.E.; Bouchat, V.; Terwagne, G.

    2010-01-01

    It is more and more necessary to improve the sensitivity of gamma-ray spectroscopy systems, especially in nuclear astrophysics. In the case of radiative proton capture reactions, one means is to avoid the reactions on the target impurities by using reverse kinematics. This technique is possible with the LARN accelerator and can provide very clean cross-section measurements. For that purpose, a hydrogen standard has been carried out by means of ion implantation in silicon. In addition, a low-level setup has been put in place on a new beam line of the accelerator. A high efficiency and high resolution germanium detector is used conjointly with a double shielding. A passive lead castle shielding system is used to reduce the natural radioactivity and an active shielding consisting of an anti-cosmic veto is provided by an anticoincidence between the plastic scintillator and the gamma-ray detector. The setup allows a reduction of 70% of the background interference and provides an approximately 200 fold sensitivity gain of between 600 and 3000 keV. Some other developments have also been carried out to optimize the setup. The entire setup and the reverse kinematics have been validated by measuring the cross-section of the 13 C(p,γ) 14 N and 15 N(p,γ) 16 O reactions that present some astrophysical interest.

  1. Alternated Prone and Supine Whole-Breast Irradiation Using IMRT: Setup Precision, Respiratory Movement and Treatment Time

    International Nuclear Information System (INIS)

    Veldeman, Liv; De Gersem, Werner; Speleers, Bruno; Truyens, Bart; Van Greveling, Annick; Van den Broecke, Rudy; De Neve, Wilfried

    2012-01-01

    Purpose: The objective of this study was to compare setup precision, respiration-related breast movement and treatment time between prone and supine positions for whole-breast irradiation. Methods and Materials: Ten patients with early-stage breast carcinoma after breast-conserving surgery were treated with prone and supine whole breast-irradiation in a daily alternating schedule. Setup precision was monitored using cone-beam computed tomography (CBCT) imaging. Respiration-related breast movement in the vertical direction was assessed by magnetic sensors. The time needed for patient setup and for the CBCT procedure, the beam time, and the length of the whole treatment slot were also recorded. Results: Random and systematic errors were not significantly different between positions in individual patients for each of the three axes (left-right, longitudinal, and vertical). Respiration-related movement was smaller in prone position, but about 80% of observations showed amplitudes <1 mm in both positions. Treatment slots were longer in prone position (21.2 ± 2.5 min) than in supine position (19.4 ± 0.8 min; p = 0.044). Conclusion: Comparison of setup precision between prone and supine position in the same patient showed no significant differences in random and systematic errors. Respiratory movement was smaller in prone position. The longer treatment slots in prone position can probably be attributed to the higher repositioning need.

  2. The Space Station Photovoltaic Panels Plasma Interaction Test Program: Test plan and results

    Science.gov (United States)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1989-01-01

    The Plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  3. The Space Station photovoltaic panels plasma interaction test program - Test plan and results

    Science.gov (United States)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1990-01-01

    The plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  4. A long arm for ultrasound: a combined robotic focused ultrasound setup for magnetic resonance-guided focused ultrasound surgery.

    Science.gov (United States)

    Krafft, Axel J; Jenne, Jürgen W; Maier, Florian; Stafford, R Jason; Huber, Peter E; Semmler, Wolfhard; Bock, Michael

    2010-05-01

    Focused ultrasound surgery (FUS) is a highly precise noninvasive procedure to ablate pathogenic tissue. FUS therapy is often combined with magnetic resonance (MR) imaging as MR imaging offers excellent target identification and allows for continuous monitoring of FUS induced temperature changes. As the dimensions of the ultrasound (US) focus are typically much smaller than the targeted volume, multiple sonications and focus repositioning are interleaved to scan the focus over the target volume. Focal scanning can be achieved electronically by using phased-array US transducers or mechanically by using dedicated mechanical actuators. In this study, the authors propose and evaluate the precision of a combined robotic FUS setup to overcome some of the limitations of the existing MRgFUS systems. Such systems are typically integrated into the patient table of the MR scanner and thus only provide an application of the US wave within a limited spatial range from below the patient. The fully MR-compatible robotic assistance system InnoMotion (InnoMedic GmbH, Herxheim, Germany) was originally designed for MR-guided interventions with needles. It offers five pneumatically driven degrees of freedom and can be moved over a wide range within the bore of the magnet. In this work, the robotic system was combined with a fixed-focus US transducer (frequency: 1.7 MHz; focal length: 68 mm, and numerical aperture: 0.44) that was integrated into a dedicated, in-house developed treatment unit for FUS application. A series of MR-guided focal scanning procedures was performed in a polyacrylamide-egg white gel phantom to assess the positioning accuracy of the combined FUS setup. In animal experiments with a 3-month-old domestic pig, the system's potential and suitability for MRgFUS was tested. In phantom experiments, a total targeting precision of about 3 mm was found, which is comparable to that of the existing MRgFUS systems. Focus positioning could be performed within a few seconds

  5. SU-F-T-642: Sub Millimeter Accurate Setup of More Than Three Vertebrae in Spinal SBRT with 6D Couch

    International Nuclear Information System (INIS)

    Wang, X; Zhao, Z; Yang, J; Yang, J; McAleer, M; Brown, P; Li, J; Ghia, A

    2016-01-01

    Purpose: To assess the initial setup accuracy in treating more than 3 vertebral body levels in spinal SBRT using a 6D couch. Methods: We retrospectively analyzed last 20 spinal SBRT patients (4 cervical, 9 thoracic, 7 lumbar/sacrum) treated in our clinic. These patients in customized immobilization device were treated in 1 or 3 fractions. Initial setup used ExacTrac and Brainlab 6D couch to align target within 1 mm and 1 degree, following by a cone beam CT (CBCT) for verification. Our current standard practice allows treating a maximum of three continuous vertebrae. Here we assess the possibility to achieve sub millimeter setup accuracy for more than three vertebrae by examining the residual error in every slice of CBCT. The CBCT had a range of 17.5 cm, which covered 5 to 9 continuous vertebrae depending on the patient and target location. In the study, CBCT from the 1st fraction treatment was rigidly registered with the planning CT in Pinnacle. The residual setup error of a vertebra was determined by expanding the vertebra contour on the planning CT to be large enough to enclose the corresponding vertebra on CBCT. The margin of the expansion was considered as setup error. Results: Out of the 20 patients analyzed, initial setup accuracy can be achieved within 1 mm for a span of 5 or more vertebrae starting from T2 vertebra to inferior vertebra levels. 2 cervical and 2 upper thoracic patients showed the cervical spine was difficult to achieve sub millimeter accuracy for multi levels without a customized immobilization headrest. Conclusion: If the curvature of spinal columns can be reproduced in customized immobilization device during treatment as simulation, multiple continuous vertebrae can be setup within 1 mm with the use of a 6D couch.

  6. SU-F-T-642: Sub Millimeter Accurate Setup of More Than Three Vertebrae in Spinal SBRT with 6D Couch

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X; Zhao, Z; Yang, J; Yang, J; McAleer, M; Brown, P; Li, J; Ghia, A [MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To assess the initial setup accuracy in treating more than 3 vertebral body levels in spinal SBRT using a 6D couch. Methods: We retrospectively analyzed last 20 spinal SBRT patients (4 cervical, 9 thoracic, 7 lumbar/sacrum) treated in our clinic. These patients in customized immobilization device were treated in 1 or 3 fractions. Initial setup used ExacTrac and Brainlab 6D couch to align target within 1 mm and 1 degree, following by a cone beam CT (CBCT) for verification. Our current standard practice allows treating a maximum of three continuous vertebrae. Here we assess the possibility to achieve sub millimeter setup accuracy for more than three vertebrae by examining the residual error in every slice of CBCT. The CBCT had a range of 17.5 cm, which covered 5 to 9 continuous vertebrae depending on the patient and target location. In the study, CBCT from the 1st fraction treatment was rigidly registered with the planning CT in Pinnacle. The residual setup error of a vertebra was determined by expanding the vertebra contour on the planning CT to be large enough to enclose the corresponding vertebra on CBCT. The margin of the expansion was considered as setup error. Results: Out of the 20 patients analyzed, initial setup accuracy can be achieved within 1 mm for a span of 5 or more vertebrae starting from T2 vertebra to inferior vertebra levels. 2 cervical and 2 upper thoracic patients showed the cervical spine was difficult to achieve sub millimeter accuracy for multi levels without a customized immobilization headrest. Conclusion: If the curvature of spinal columns can be reproduced in customized immobilization device during treatment as simulation, multiple continuous vertebrae can be setup within 1 mm with the use of a 6D couch.

  7. Surface imaging, portal imaging, and skin marker set-up vs. CBCT for radiotherapy of the thorax and pelvis

    International Nuclear Information System (INIS)

    Pallotta, Stefania; Bucciolini, Marta; Vanzi, Eleonora; Marrazzo, Livia; Simontacchi, Gabriele; Paiar, Fabiola; Ceroti, Marco; Livi, Lorenzo

    2015-01-01

    The aim of this study was to compare surface imaging, portal imaging, and skin marker set-up in radiotherapy of thoracic and pelvic regions, using cone beam computed tomography (CBCT) data as the gold standard. Twenty patients were included in this study. CBCT, surface acquisition (SA), and two orthogonal portal images (PI) were acquired during the first four treatment sessions. Patient set-up corrections, obtained by registering the planning CT with CBCT, were used as the gold standard. Registration results of the PI and SA were evaluated and compared with those obtained with CBCT. The advantage derived from using SA or PI verification systems over a skin marker set-up was also quantified. A statistically significant difference between PI and SA (in favour of PI) was observed in seven patients undergoing treatment of the pelvic region and in two patients undergoing treatment of the thoracic region. The use of SA or PI, compared with a skin marker set-up, improved patient positioning in 50% and 57 % of the thoracic fractions, respectively. For pelvic fractions, the use of PI was beneficial in 73 % of the cases, while the use of SA was beneficial in only 45 %. Patient positioning worsened with SA, particularly along longitudinal and vertical directions. PI yielded more accurate registration results than SA for both pelvic and thoracic fractions. Compared with the skin marker set-up, PI performances were superior to SA for pelvic fractions while comparable results were obtained for thoracic fractions. (orig.) [de

  8. Experimental Study of Drag Resistance using a Laboratory Scale Rotary Set-Up

    DEFF Research Database (Denmark)

    Erik Weinell, Claus; Olsen, Kenneth N.; Christoffersen, Martin W.

    2003-01-01

    This work covers an experimental study of the drag resistance of different painted surfaces and simulated large-scale irregularities, viz. dry spraying, weld seams, barnacle fouling and paint remains. A laboratory scale rotary set-up was used to determine the drag resistance, and the surface...

  9. Multi-Objective Optimization of the Setup of a Surfactant-Enhanced DNAPL Remediation

    NARCIS (Netherlands)

    Schaerlaekens, J.; Carmeliet, J.; Feyen, J.

    2005-01-01

    Surfactant-enhanced aquifer remediation (SEAR) is widely considered a promising technique to remediate dense nonaqueous phase liquid (DNAPL) contaminations in-situ. The costs of a SEAR remediation are important and depend mostly on the setup of the remediation. Costs can be associated with the

  10. Application of Negative Curvature Hollow-Core Fiber in an Optical Fiber Sensor Setup for Multiphoton Spectroscopy.

    Science.gov (United States)

    Popenda, Maciej Andrzej; Stawska, Hanna Izabela; Mazur, Leszek Mateusz; Jakubowski, Konrad; Kosolapov, Alexey; Kolyadin, Anton; Bereś-Pawlik, Elżbieta

    2017-10-06

    In this paper, an application of negative curvature hollow core fiber (NCHCF) in an all-fiber, multiphoton fluorescence sensor setup is presented. The dispersion parameter (D) of this fiber does not exceed the value of 5 ps/nm × km across the optical spectrum of (680-750) nm, making it well suited for the purpose of multiphoton excitation of biological fluorophores. Employing 1.5 m of this fiber in a simple, all-fiber sensor setup allows us to perform multiphoton experiments without any dispersion compensation methods. Multiphoton excitation of nicotinamide adenine dinucleotide (NADH) and flavin adenine dinucleotide (FAD) with this fiber shows a 6- and 9-fold increase, respectively, in the total fluorescence signal collected when compared with the commercial solution in the form of a hollow-core photonic band gap fiber (HCPBF). To the author's best knowledge, this is the first time an NCHCF was used in an optical-fiber sensor setup for multiphoton fluorescence experiments.

  11. Relative performance of priority rules for hybrid flow shop scheduling with setup times

    Directory of Open Access Journals (Sweden)

    Helio Yochihiro Fuchigami

    2015-12-01

    Full Text Available This paper focuses the hybrid flow shop scheduling problem with explicit and sequence-independent setup times. This production environment is a multistage system with unidirectional flow of jobs, wherein each stage may contain multiple machines available for processing. The optimized measure was the total time to complete the schedule (makespan. The aim was to propose new priority rules to support the schedule and to evaluate their relative performance at the production system considered by the percentage of success, relative deviation, standard deviation of relative deviation, and average CPU time. Computational experiments have indicated that the rules using ascending order of the sum of processing and setup times of the first stage (SPT1 and SPT1_ERD performed better, reaching together more than 56% of success.

  12. Design of a setup for {sup 252}Cf neutron source for storage and analysis purpose

    Energy Technology Data Exchange (ETDEWEB)

    Hei, Daqian [Department of Nuclear Science and Engineering, College of Materials Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 211106 (China); Zhuang, Haocheng [Xi’an Middle School of Shanxi Province, Xi’an 710000 (China); Jia, Wenbao, E-mail: jiawenbao@163.com [Department of Nuclear Science and Engineering, College of Materials Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 211106 (China); Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Suzhou 215000 (China); Cheng, Can; Jiang, Zhou; Wang, Hongtao [Department of Nuclear Science and Engineering, College of Materials Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 211106 (China); Chen, Da [Department of Nuclear Science and Engineering, College of Materials Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 211106 (China); Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Suzhou 215000 (China)

    2016-11-01

    {sup 252}Cf is a reliable isotopic neutron source and widely used in the prompt gamma ray neutron activation analysis (PGNAA) technique. A cylindrical barrel made by polymethyl methacrylate contained with the boric acid solution was designed for storage and application of a 5 μg {sup 252}Cf neutron source. The size of the setup was optimized with Monte Carlo code. The experiments were performed and the results showed the doses were reduced with the setup and less than the allowable limit. The intensity and collimating radius of the neutron beam could also be adjusted through different collimator.

  13. The Impact of use of Double Set-up on Infection Rates in Revision Total Knee Replacement and Limb Salvage Procedures

    Directory of Open Access Journals (Sweden)

    Jennifer Waterman

    2015-03-01

    Full Text Available A retrospective analysis was performed to determine the impact of utilizing a double set-up procedure on reducing infection rates revision total knee and limb salvage procedures in patients with known joint infection.  Eighteen cases fit selection criteria.  The recurrence rate of infection was 5.5% which is less than reported recent literature review.   This suggests the use of a double set-up in combination with other infection reducing protocols may help further reduce recurrent infection.  Keywords: double set-up, infection, revision total knee arthroplasty, limb-salvage

  14. Improvement of the polarized neutron interferometer setup demonstrating violation of a Bell-like inequality

    Energy Technology Data Exchange (ETDEWEB)

    Geppert, H., E-mail: hgeppert@ati.ac.at [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Vienna (Austria); Denkmayr, T.; Sponar, S. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Vienna (Austria); Lemmel, H. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Vienna (Austria); Institut Laue Langevin, 38000 Grenoble (France); Hasegawa, Y. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Vienna (Austria)

    2014-11-01

    For precise measurements with polarised neutrons high efficient spin-manipulation is required. We developed several neutron optical elements suitable for a new sophisticated setup, i.e., DC spin-turners and Larmor-accelerators which diminish thermal disturbances and depolarisation considerably. The gain in performance is exploited demonstrating violation of a Bell-like inequality for a spin-path entangled single-neutron state. The obtained value of S=2.365(13), which is much higher than previous measurements by neutron interferometry, is 28σ above the limit of S=2 predicted by contextual hidden variable theories. The new setup is more flexible referring to state preparation and analysis, therefore new, more precise measurements can be carried out.

  15. Improvement of the polarized neutron interferometer setup demonstrating violation of a Bell-like inequality.

    Science.gov (United States)

    Geppert, H; Denkmayr, T; Sponar, S; Lemmel, H; Hasegawa, Y

    2014-11-01

    For precise measurements with polarised neutrons high efficient spin-manipulation is required. We developed several neutron optical elements suitable for a new sophisticated setup, i.e., DC spin-turners and Larmor-accelerators which diminish thermal disturbances and depolarisation considerably. The gain in performance is exploited demonstrating violation of a Bell-like inequality for a spin-path entangled single-neutron state. The obtained value of [Formula: see text], which is much higher than previous measurements by neutron interferometry, is [Formula: see text] above the limit of S =2 predicted by contextual hidden variable theories. The new setup is more flexible referring to state preparation and analysis, therefore new, more precise measurements can be carried out.

  16. Split-Hopkinson Pressure Bar: an experimental technique for high strain rate tests

    International Nuclear Information System (INIS)

    Sharma, S.; Chavan, V.M.; Agrawal, R.G.; Patel, R.J.; Kapoor, R.; Chakravartty, J.K.

    2011-06-01

    Mechanical properties of materials are, in general, strain rate dependent, i.e. they respond differently at quasi-static and higher strain rate condition. The Split-Hopkinson Pressure Bar (SHPB), also referred to as Kolsky bar is a commonly used setup for high strain rate testing. SHPB is suitable for high strain rate test in strain rate range of 10 2 to 10 4 s -1 . These high strain rate data are required for safety and structural integrity assessment of structures subjected to dynamic loading. As high strain rate data are not easily available in open literature need was felt for setting up such high strain rate testing machine. SHPB at BARC was designed and set-up inhouse jointly by Refuelling Technology Division and Mechanical Metallurgy Division, at Hall no. 3, BARC. A number of conceptual designs for SHPB were thought of and the optimized design was worked out. The challenges of precision tolerance, straightness in bars and design and proper functioning of pneumatic gun were met. This setup has been used extensively to study the high strain rate material behavior. This report introduces the SHPB in general and the setup at BARC in particular. The history of development of SHPB, the basic formulations of one dimensional wave propagation, the relations between the wave velocity, particle velocity and elastic strain in a one dimensional bar, and the equations used to obtain the final stress vs. strain curves are described. The calibration of the present setup, the pre-test calculations and the posttest analysis of data are described. Finally some of the experimental results on different materials such as Cu, SS305, SA516 and Zr, at room temperature and elevated temperatures are presented. (author)

  17. A new beam diagnostic system for the MASHA setup

    International Nuclear Information System (INIS)

    Motycak, S.; Kamas, D.; Rodin, A.M.; Novoselov, A.S.; Podshibyakin, A.V.; Belozerov, A.V.; Vedeneyev, V.Yu.; Gulyaev, A.V.; Gulyaeva, A.V.; Salamatin, V.S.; Stepantsov, S.V.; Chernysheva, E.V.; Yukhimchuk, S.A.; Komarov, A.B.; Krupa, L.; Kliman, J.

    2016-01-01

    A new beam diagnostic system based on the PXI standard was developed, tested, and used in the MASHA setup experiment. The beam energy and beam current measurements were carried out using several methods. The online time-of-flight energy measurements were carried out using three pick-up detectors. We used two electronic systems to measure the time between the pick-ups. The first system was based on fast Agilent digitizers (2-channel, 4-GHz sampling rate), and the second one was based on a constant fraction discriminator (CFD) connected to a time-to-digital converter (TDC, 5-ps resolution). A new graphical interface to monitor the electronic devices and to perform the online calculations of energy was developed using MFC C ++. The second system based on microchannel plate (time-of-flight) and silicon detectors for the determination of beam energy and the type of accelerated particles was also used. The beam current measurements were carried out with two different sensors. The first sensor is a rotating Faraday cup placed in front of the target, and the second one is an emission detector installed at the rear of the target. This system is now used in experiments for the synthesis of superheavy elements at the U400M cyclotron of the Flerov Laboratory of Nuclear Reactions (FLNR).

  18. A new beam diagnostic system for the MASHA setup

    Science.gov (United States)

    Motycak, S.; Rodin, A. M.; Novoselov, A. S.; Podshibyakin, A. V.; Krupa, L.; Belozerov, A. V.; Vedeneyev, V. Yu.; Gulyaev, A. V.; Gulyaeva, A. V.; Kliman, J.; Salamatin, V. S.; Stepantsov, S. V.; Chernysheva, E. V.; Yuchimchuk, S. A.; Komarov, A. B.; Kamas, D.

    2016-09-01

    A new beam diagnostic system based on the PXI standard was developed, tested, and used in the MASHA setup experiment. The beam energy and beam current measurements were carried out using several methods. The online time-of-flight energy measurements were carried out using three pick-up detectors. We used two electronic systems to measure the time between the pick-ups. The first system was based on fast Agilent digitizers (2-channel, 4-GHz sampling rate), and the second one was based on a constant fraction discriminator (CFD) connected to a time-to-digital converter (TDC, 5-ps resolution). A new graphical interface to monitor the electronic devices and to perform the online calculations of energy was developed using MFC C++. The second system based on microchannel plate (time-of-flight) and silicon detectors for the determination of beam energy and the type of accelerated particles was also used. The beam current measurements were carried out with two different sensors. The first sensor is a rotating Faraday cup placed in front of the target, and the second one is an emission detector installed at the rear of the target. This system is now used in experiments for the synthesis of superheavy elements at the U400M cyclotron of the Flerov Laboratory of Nuclear Reactions (FLNR).

  19. A differential dielectric spectroscopy setup to measure the electric dipole moment and net charge of colloidal quantum dots.

    Science.gov (United States)

    Kortschot, R J; Bakelaar, I A; Erné, B H; Kuipers, B W M

    2014-03-01

    A sensitive dielectric spectroscopy setup is built to measure the response of nanoparticles dispersed in a liquid to an alternating electric field over a frequency range from 10(-2) to 10(7) Hz. The measured complex permittivity spectrum records both the rotational dynamics due to a permanent electric dipole moment and the translational dynamics due to net charges. The setup consists of a half-transparent capacitor connected in a bridge circuit, which is balanced on pure solvent only, using a software-controlled compensating voltage. In this way, the measured signal is dominated by the contributions of the nanoparticles rather than by the solvent. We demonstrate the performance of the setup with measurements on a dispersion of colloidal CdSe quantum dots in the apolar liquid decalin.

  20. A low-cost AFM setup with an interferometer for undergraduates and secondary-school students

    International Nuclear Information System (INIS)

    Bergmann, Antje; Feigl, Daniela; Kuhn, David; Schaupp, Manuel; Quast, Günter; Busch, Kurt; Eichner, Ludwig; Schumacher, Jens

    2013-01-01

    Atomic force microscopy (AFM) is an important tool in nanotechnology. This method makes it possible to observe nanoscopic surfaces beyond the resolution of light microscopy. In order to provide undergraduate and secondary-school students with insights into this world, we have developed a very robust low-cost AFM setup with a Fabry–Perot interferometer as a detecting device. This setup is designed to be operated almost completely manually and its simplicity gives access to a profound understanding of the working principle. Our AFM is operated in a constant height mode, i.e. the topography of the sample surface is represented directly by the deflection of the cantilever. Thus, the measuring procedure can be understood even by secondary-school students; furthermore, it is the method with the lowest cost, totalling not more than 10–15 k Euros. Nevertheless, we are able to examine a large variety of sample topographies such as CD and DVD surfaces, IC structures, blood cells, butterfly wings or moth eyes. Furthermore, force–distance curves can be recorded and the tensile moduli of some materials can be evaluated. We present our setup in detail and describe its working principles. In addition, we show various experiments which have already been performed by students. (paper)