WorldWideScience
1

High-resolution primary ion beam probe for SIMS  

Energy Technology Data Exchange (ETDEWEB)

High-brightness negative ion beams, especially O{sup -} beams, from a compact gaseous plasma source are studied to evaluate the suitability for high-resolution SIMS. Ion-optical calculations are made using the beam parameters from the new source. Results suggest that sub-100 nm spot with O{sup -} beam current of 10 pA is achievable. Beam focusing, the resulting beam current distributions at the target and the expected instrumental performance are discussed.

2004-06-15

2

Simultaneous recognition and segmentation of cells: application in C.elegans  

UK PubMed Central (United Kingdom)

Motivation: Automatic recognition of cell identities is critical for quantitative measurement, targeting and manipulation of cells of model animals at single-cell resolution. It has been...Full Text Available

2011-10-15

3

Development of nanometer resolution C-Band radio frequency beam position monitors in the Final Focus Test Beam  

Energy Technology Data Exchange (ETDEWEB)

Using a 47 GeV electron beam, the Final Focus Test Beam (FFTB) produces vertical spot sizes around 70 nm. These small beam sizes introduce an excellent opportunity to develop and test high resolution Radio Frequency Beam Position Monitors (RF-BPMs). These BPMs are designed to measure pulse to pulse beam motion (jitter) at a theoretical resolution of approximately 1 nm. The beam induces a TM{sub 110} mode with an amplitude linearly proportional to its charge and displacement from the BPM's (cylindrical cavity) axis. The C-band (5,712 MHz) TM{sub 110} signal is processed and converted into beam position for use by the Stanford Linear Collider (SLC) control system. Presented are the experimental procedures, acquisition, and analysis of data demonstrating resolution of jitter near 25 nm. With the design of future e{sup +}e{sup -} linear colliders requiring ...

1998-08-01

4

NEXAFS microscopy of polymeric materials: Successes and challenges encountered when characterizing organic devices  

Energy Technology Data Exchange (ETDEWEB)

We summarize recent developments in x-ray microscopy of polymers by focusing on the characterization of organic electronic devices. The quantitative compositions of model polymer blends have been mapped at a resolution of {approx}35 nm. Since it could be inferred that these devices have structures smaller than 35 nm, quantitative compositional mapping at length scales below the present resolution limit of x-ray microscopy is required. Organic devices thus serve to both highlight the success of NEXAFS microscopy to date, but to also outline the very real need for higher spatial resolution. New approaches to create improved optics or different acquisition modalities are required if x-ray microscopy is to make sustained contributions to such an important area of research as organic devices.

2009-09-01

5

Imaging magnetic domain structure in sub-500 nm thin film elements  

Energy Technology Data Exchange (ETDEWEB)

Magnetic imaging in the transmission electron microscope (TEM) has been used to examine submicron elements with the aim of discovering down to what element size complex domain patterns can form. The elements were squares, circles, triangles, and pentagons in the size range 100{endash}500 nm and were made from 36 nm Co films or 8 nm Ni{sub 80}Fe{sub 20} (NiFe) with in-plane magnetization. The magnetic domain structures in these elements were imaged at high resolution using the differential phase contrast imaging mode in a TEM. Nonuniform magnetization structures were seen in the images. Vortices were present at remanence in all shapes of 36-nm-thick Co elements down to 100 nm size and in circular NiFe elements down to 116 nm diameter. Triangular NiFe elements did not have a vortex state at remanence, instead the magnetization curved round ...

2001-06-01

6

Histological analysis of 70-nm silica particles-induced chronic toxicity in mice  

British Library Electronic Table of Contents (United Kingdom)

Nano-sized silica is a promising material for disease diagnosis, cosmetics and drugs. For the successful application of nano-sized material in bioscience, evaluation of nano-sized material toxicity is important. We previously found that nano-sized silica particles with a diameter of 70nm showed acute liver failure in mice. Here, we performed histological analysis of major organs such as the liver, spleen, lung, kidney, brain and heart in mice, chronically injected with 70-nm silica particles for 4weeks. Histological analysis revealed hepatic microgranulation and splenic megakaryocyte accumulation in these 70-nm silica particles treated mice, while the kidney, lung, brain and heart remained unaffected. Thus, liver and spleen appear to be the major target organs for toxicity by the chronic a...

2009-01-01

7

Target area chamber system design for the National Ignition Facility  

International Nuclear Information System (INIS)

The National Ignition Facility (NIF) is a proposed Department of Energy facility which will contribute to the resolution of important Defense Program and inertial fusion energy issues for energy production in the future. The NIF will consist of a laser system with 192 independent beamlets transported to a target chamber. The target chamber is a multi-purpose structure that provides the interface between the target and the laser optics. The chamber must be capable of achieving moderate vacuum levels in reasonable times; it must remain dimensionally stable within micron tolerances, provide support for the optics, diagnostics, and target positioner; it must minimize the debris from the x-ray and laser light environments; and it must be capable of supporting external neutron shielding. The chamber must also be fabricated from a low neutron activation material. The fusion reaction in the ...

1994-06-19

8

Local secondary-electron emission spectra of graphite and gold surfaces obtained using the Scanning Probe Energy Loss Spectrometer (SPELS)  

International Nuclear Information System (INIS)

Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.

2009-11-25

9

Investigations of microstructure of thin TbFeCo films by high-resolution electron microscopy  

International Nuclear Information System (INIS)

High-resolution electron microscope observations confirm the presence of small crystallites in thin TbFeCo films protected by Si_3N_4 overcoats. Selected area electron diffraction patterns in top-view projection indicate that the crystals have a face-centered-cubic structure. Microscope analysis reveals grain growth following annealing of these protected thin films at 200 degree C in vacuum, and Kerr measurements yield large reductions in coercivity relative to the room-temperature value. The typical grain size visible in top-view observations increases from about 3 nm in the as-deposited samples to about 30 nm after annealing at 200 degree C for 36 h while the static coercivity, H_c, drops by about 40%. The fcc structure of the crystals is retained after annealing.

10

Focused ion beam fabrication and properties of nanoscale Josephson junctions for sensors and other applications  

International Nuclear Information System (INIS)

The methods of superconducting device fabrication by lithography and multilevel processing usually require a number of processing steps with lithographic resolution and alignment adequate for the scale of the device be fabricated. As an alternative, the focused ion beam (FIB) microscope is increasingly being used directly to fabricate devices. A major advantage of using a FIB compared to other lithography methods is its flexibility and high resolution. It allows in-situ, milling (#propor to#5 nm at a beam current of 1 pA) to a variety of depths, and imaging (2 nm) of the sample. In this paper we describe our development of junction fabrication techniques using the FIB and their application in creating a range of potential sensor devices and quantum electronics applications. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2005-03-01

11

A VUV prism spectrometer for RICH radiator refractometry  

CERN Document Server

A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

2000-01-01

12

The wavelength dependence of ultraviolet enhanced reactivation in a mammalian cell-virus system  

International Nuclear Information System (INIS)

The effect of UV radiation in the wavelength region 230 nm to 302 nm on the ability of an irradiated mammalian cell to reactivate UV-irradiated mammalian virus was tested. An action spectrum for radiation enhanced reactivation (RER) is presented. The shape of the action spectrum points to a combined nucleic acid-protein target for UV radiation effects on this cellular parameter. An analysis of the results of others involving the biochemical and photobiological events involved in RER does not allow us to distinguish which macromolecule is the major contributor to this effect. Studies involving an analogous phenomenon in bacteris (Weigle reactivation) imply that RER and WR amy involve similar mechanisms. (author).

13

High resolution transmission electron microscopy of a #beta#'-sialon-TiN nanocomposite  

International Nuclear Information System (INIS)

TEM and HRTEM have been used to characterise the microstructures of materials formed by hot-pressing silicon nitride with an Al_2O_3-SiO_2-TiO_2 densification aid system, to form #beta#'-sialon-TiN composites in which the TiN particles are of 20-100 nm dimension. (orig.).

1992-06-21

14

Luminescence of Strontianite (SrCO{sub 3}) from Strontian (Scotland, UK)  

Energy Technology Data Exchange (ETDEWEB)

An historic Strontianite-type specimen from Strontian, Scotland, UK, was characterized to broaden our knowledge on luminescence properties of common carbonates. These fibrous aggregates are Strontianite (Sr{sub x}Ca{sub 1-x}CO{sub 3}) with circa 6% of CaO, interfacial water, hydrosilicate anions and substitutional divalent cations, e.g., Ca{sup 2+}, Mn{sup 2+}, Fe{sup 2+} in structural Sr{sup 2+} positions. The specimen was analyzed by X-ray Fluorescence Spectrometry (XRF), Environmental Scanning Electron Microscopy coupled with an Energy Dispersive X-ray Spectroscopy (ESEM-EDS) probe, Spatially-resolved Cathodoluminescence under the Scanning Electron Microscope (SEM-CL), Differential-Thermal Analyses (DTA), Thermogravimetry (TG), Thermoluminescence (TL), Radioluminescence (RL) and High Resolution Spectra Thermoluminescence (3DTL), to gain an overview of the spectral emissions, the defect linkages were modified by heating from room temperature (RT) up to 500 deg. ...

2009-04-15

15

Production of a helium beam in a focused ion beam machine using an electron beam ion trap  

International Nuclear Information System (INIS)

Gallium liquid-metal ion sources that have been introduced in the late 1970s have allowed the development of a new class of micro- and nanofabrication tools collectively denominated as focused ion beam (FIB) machines. To investigate the potential of a helium beam in such a FIB instrument the authors have tested a room-temperature electron beam ion trap coupled with a high resolution FIB machine. In this letter they present their first results in target imaging using a helium beam with a resolution that allows to account for a beam diameter in the submicrometer range.

2007-02-19

16

Study of the crystallographic architecture of corals at the nanoscale by scanning transmission X-ray microscopy and transmission electron microscopy.  

Science.gov (United States)

We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the ...

2011-05-05

17

Synthesis and characterization of ["1"2"5I]-N-(N-benzylpiperidin-4-YL)-4-iodobenz amide, a potential high affinity sigma ligand for imaging breast cancer  

International Nuclear Information System (INIS)

Three regio-isomers of N-(N-benzylpiperidin-4-yl)-4-iodobenzamide, IBP, were prepared and evaluated for their sigma affinities. All three isomers (2, 3, and 4-substituted) showed high affinities for sigma-1 receptors in guinea pig brain membranes (Ki - 1.64 nM, 3.02 nM, 1.70 nM respectively) against ["3H]-(+)-pentazocine, a sigma-1 selective ligand. 2-IBP and 4-IBP showed modest affinities for sigma-2 sites in rat liver (Ki = 29.6 nM. 25.2 nM respectively) against ["3H]DTG in the presence of dextrallorphan to mask sigma-1 sites. The homologous competition binding studies of 4-["1"2"5I]BP in MCF-7 human breast tumor cells showed high affinity dose-dependent binding. Competition binding studies with haloperidol and DTG also showed a high affinity binding (Ki = 4.6 nM, 60 nM respectively), demonstrating the sigma specificity. The saturation ...

1994-08-21

18

Origins of residual stress in Mo and Ta films: The role of impurities, microstructural evolution, and phase transformations  

Energy Technology Data Exchange (ETDEWEB)

Both the sign and magnitude of residual stress can vary with the thickness of sputter deposited films. The origins of this behavior are not well understood. In this work, the authors consider the correlation between the residual stress behavior and the depth dependence of impurities in thin (2.5 nm--150 nm) sputtered Mo and Ta films. They also consider the effects of phase transformations and microstructural changes on the stress behavior. Films were deposited onto Si substrates with native oxide. The residual stress observed in the Mo films varied from highly compressive at 2.5 nm film thickness to {approximately}0 at 10 nm thickness. Ta films also exhibited a high compressive stress, which relaxed from highly compressive to tensile between 10 nm and 50 nm film thickness. Impurities in the films may originate from the sputtering targets, ...

1997-05-01

19

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

Energy Technology Data Exchange (ETDEWEB)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the ...

2006-06-15

20

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

International Nuclear Information System (INIS)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the ...

2006-06-01

21

Development of magnetic separation system of magnetoliposomes  

Energy Technology Data Exchange (ETDEWEB)

The magnetic separation technology using sub-microsized ferromagnetic particle is indispensable in many areas of medical biosciences. For example, ferromagnetic particles (200-500 nm) are widely used for cell sorting in stem cell research with the use of cell surface-specific antigens. Nanosized ferromagnetic particles (10-20 nm) have been suggested as more suitable in drug delivery studies given their efficiency of tissue penetration, however, the magnetic separation method for them has not been established. One of the major reasons is that magnetic force acting on the object particles decreases drastically as a particle diameter becomes small. In this study, magnetic force acting on the targets was enhanced by the combination of superconducting magnet and the filter consisting of ferromagnetic particle. By doing so, we confirmed that Fe{sub 3}O{sub 4} of 20 nm in diameter was trapped in the magnetic ...

2009-10-15

22

Gauging film thickness: A comparison of an x-ray diffraction technique with Rutherford backscattering spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.

1985-01-15

23

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.

2004-04-01

24

Some properties of atomic beam produced by laser induced ablation of Li target  

International Nuclear Information System (INIS)

Pulsed atomic beams produced in vacuum by laser induced ablation from a lithium target are analyzed by laser induced fluorescence (LIF). The 1-mixing processes induced in the n = 9, 10 Li Rydberg states by collisions with CO_2 molecules illustrate the application of the method. Resolution is limited by the 1 mm diameter of the probe laser beam. Combining LIF and absorption measurements gives n_L_i as a function of time at various distances from the target surface. The investigation of the Li-C0_2 1-mixing process in a heat pipe oven proved impossible due to the high reactivity of Li with C0_2. This problem was solved by renewing the Li atoms at each laser shot. Values obtained for n = 9, n = 10 are k = 17 x 10"-"8 and 15 x 10"-"8 cc/sec, respectively.

25

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

26

High resolution electron microscopy study of as-prepared and annealed tungsten-carbon multilayers  

International Nuclear Information System (INIS)

A series of sputtered tungsten-carbon multilayer structures with periods ranging from 2 to 12 nm in the as-prepared state and after annealing at 500 degrees C for 4 hours has been studied with high resolution transmission electron microscopy. The evolution with annealing of the microstructure of these multilayers depends on their period.As-prepared structures appear predominantly amorphous from TEM imaging and diffraction. Annealing results in crystallization of the W-rich layers into WC in the larger period samples, and less complete or no crystallization in the smaller period samples. X-ray scattering reveals that annealing expands the period in a systematic way. The layers remain remarkably well-defined after annealing under these conditions.

27

Creation of nitrogen-vacancy centres in diamond with high resolution  

International Nuclear Information System (INIS)

Nowadays, diamond and the nitrogen-vacancy (NV) colour centres constitute the best solid-state system in view of quantum-computing applications. It has also been shown recently that single NV centres could be used as nanoscale magnetic sensors. Such applications require the creation of single NV centres with very high resolution and with a high efficiency. The nano-implanter at the university of Bochum provides low energy nitrogen ions which can be implanted through a hole pierced in the tip of an atomic force microscope. Ultrapure diamond samples have been implanted with spot sizes of 50nm and less. Stimulated Emission Depletion (STED) microscopy has been used to characterise and resolve the implanted spots.

2010-03-21

28

Pharmaceutics | Special Issue: Molecular Imaging  

Wastenet

...) Abstract: Fluorescence microscopic imaging is widely used in biomedical research to study molecular and cellular processes in cell culture or tissue samples. This is motivated by the high inherent sensitivity of fluorescence techniques, the spatial resolution that compares favorably with cellular dimensions, the stability of the fluorescent labels used and the sophisticated strategies that have been developed for selectively labeling target molecules. More recently, two and ...

29

Preliminary Design of ARIES-Devasthal Faint Object Spectrograph and Camera  

CERN Document Server

We present here the preliminary design of ARIES-Devasthal Faint Object Spectrograph and Camera (ADFOSC), which is a multi-mode instrument for both imaging and spectroscopy. ADFOSC is the first-generation instrument to be mounted at the axial port of the Cassegrain focus on our new 3.6m optical telescope to be installed at Devasthal, Nainital. The main design goals of the instrument are : the instrument will have capability of broad- and narrow-band imaging, low-medium resolution spectroscopy, and imaging polarimetry. The operating wavelength range will be from 360 to 1000 nm and the instrument will have remote-control capability.

2009-01-01

30

Measurement of liquid xenon scintillation from heavy ions using a silicon photodiode  

Energy Technology Data Exchange (ETDEWEB)

Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).

1991-11-15

31

Grain boundary dissociation by the emission of stacking faults  

Energy Technology Data Exchange (ETDEWEB)

A range of <110> symmetric tilt grain boundaries (GBs) are investigated in several fcc metals with simulations and high resolution electron microscopy. Boundaries with tilt angles between 50.5{degree} and 109.5{degree} dissociate into two boundaries 0.6 to 1.1 nm apart. The dissociation takes place by the emission of stacking faults from one boundary that are terminated by Shockley partials at a second boundary. This is a general mode of GB relaxation for low stacking fault energy metals. The reasons for the occurrence of this relaxation mode are discussed using the theory of GB dislocations.

1995-05-01

32

Study of free electron laser (FEL) using the electron storage ring 'NIJI-IV'  

International Nuclear Information System (INIS)

We have constructed a racetrack-type compact electron storage ring 'NIJI-IV' for UV FEL. The ring has a hexagonal configuration with two 7.25 m-long straight sections, though its circumference is 29.6 m. A 6.3 m optical klystron (OK) for high FEL gain was installed in one of the long straight sections. The experimental setup for FEL lasing was started at the end of April 1992. The setup on the ring with the OK and the cavity mirror alignment have been completed. The FEL lasings using the NIJI-IV were accomplished at 595-589 nm on August 18, 1992 and at 488 nm on September 18, 1992. The final development target is stable FEL lasing in the UV range. (author).

33

Responses of the blister beetle Hycleus apicicornis to visual stimuli  

British Library Electronic Table of Contents (United Kingdom)

Insect attraction to host plants may be partly mediated by visual stimuli. In the present study, the responses of adult Hycleus apicicornis (Gur.) (Coleoptera: Meloidae) to plant models of different colours, different combinations of two colours, or three hues of blue of different shapes are compared. Single-colour models comprised the colours sky blue, bright green, yellow, red, white and black. Sky blue (reflecting light in the 440-500 nm region) is the most attractive, followed by white, which reflects light over a broader range (400-700 nm). On landing on sky blue targets, beetles exhibit feeding behaviour immediately. When different hues of blue (of different shapes) are compared, sky blue is preferred over turquoise, followed by dark blue, indicating that H. apicicornis is more attra...

2011-01-01

34

Submicron-scale patterns on ferromagnetic-antiferromagnetic Fe/NiO layers by focused ion beam (FIB) milling  

Energy Technology Data Exchange (ETDEWEB)

With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga{sup +} focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to ...

2005-04-01

35

Submicron-scale patterns on ferromagnetic-antiferromagnetic Fe/NiO layers by focused ion beam (FIB) milling  

International Nuclear Information System (INIS)

With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga"+ focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the ...

2005-04-01

36

Application of low-resolution Raman spectroscopy for the analysis of oxidized olive oil  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to evaluate the potential of low-resolution Raman spectroscopy for monitoring the oxidation status of olive oil. Primary and secondary oxidation parameters such as peroxide value, K"2"3"2 and K"2"7"0 were studied. Low-resolution Raman spectra ranging from 200 to 2700 cm^-^1 in a set of 126 oxidized and virgin olive oil samples were collected directly using a probe. Partial Least Squares was used to calibrate the Raman instrument for the different targeted parameters. The performance of the models was determined by using validation sets, and the best results obtained were: R^2 = 0.91, RMSEP = 2.57 for the peroxide value content; R^2 = 0.88, RMSEP = 0.37 for K"2"3"2; and R^2 = 0.90, RMSEP = 0.08 for K"2"7"0. These results demonstrated that low-resolution Raman spect...

2011-01-01

37

[Retrieval of spectral characteristics of hyperspectral sensor and retrieval of reflectance spectra].  

Science.gov (United States)

On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of ...

2010-10-01

38

ISDD: A Computational Model of Particle Sedimentation, Diffusion and Target Cell Dosimetry for In Vitro Toxicity Studies  

Energy Technology Data Exchange (ETDEWEB)

Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. ?g particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular doses for multiple sizes of polystyrene ...

2010-11-30

39

Visible and near-infrared spectral signatures for adulteration assessment of extra virgin olive oil  

Science.gov (United States)

Because of its high price, the extra virgin olive oil is frequently target for adulteration with lower quality oils. This paper presents an innovative optical technique capable of quantifying the adulteration of extra virgin olive oil caused by lowergrade olive oils. It relies on spectral fingerprinting the test liquid by means of diffuse-light absorption spectroscopy carried out by optical fiber technology in the wide 400-1700 nm spectral range. Then, a smart multivariate processing of spectroscopic data is applied for immediate prediction of adulterant concentration.

2010-04-01

40

The Magdalena Ridge Observatory 2.4 m Telescope  

Science.gov (United States)

EOS Technologies has been commissioned to design and build a unique 2.4m astronomical telescope for the Magdalena Ridge Observatory. This telescope utilizes a high quality primary mirror and cell from a now decommissioned military application. This paper describes the project and gives an overview of the telescope design. The Magdalena Ridge Observatory (MRO) 2.4 meter telescope will be primarily utilized to observe, track, and characterize solar system astronomical targets, Earth satellites, space vehicles, and terrestrial military targets. The telescope's rapid tracking (slew rates are 10o/sec) will allow it to move to any target and acquire data within one minute of receipt of notice. In this way, the telescope will be used to capitalize on targets of opportunity that occur in asteroid studies (e.g., Near Earth Objects) and in astrophysics, such as gamma ray bursts and other transient phenomena. ...

2006-07-01

41

Experimental Study of Hypernuclei Electroproduction by High Precision Spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Jlab experiment E01-011, carried out in 2005 in JLab Hall C, is the second generation of the hypernuclear spectroscopy experiments by the (e,e{prime}K{sup +}) reaction. The (e,e{prime}K{sup +}) reaction is complimentary to the associated production reactions (K{sup -},{pi}{sup -}), ({pi}{sup +},K{sup +}) since, due to a larger momentum transfer to a hyperon, excitations of both spin-non-flip and spin-flip states are possible. The experiment uses high quality and continuous primary electron beam to produce neutron rich hypernuclei on various targets by the electroproduction. The experimental setup consists of splitter magnet, high resolution kaon spectrometer (HKS) and electron spectrometer (Enge) implemented in new configuration, the so called 'Tilt Method'. Production data was taken on multiple targets: CH{sub 2}, {sup 6}Li, {sup 7}Li, {sup 9}Be, {sup 10}B, {sup 12}C and {sup 28}Si. In present study the ...

2009-12-01

42

Total suspended matter observation in the Pearl River estuary from in situ and MERIS data.  

Science.gov (United States)

Based on the cruise data collected in the Pearl River estuary (PRE) in May 2008, an empirical two-band model by using the ratio of R (rs) at 629 and 671 nm was established to retrieve total suspended matter (TSM) concentration with the determination coefficient (R(2)) of 0.854, mean relative error (MRE) of 7.483%, and root-mean-square error (RMSE) of 1.295 mg L(?-?1). To match with medium resolution imaging spectrometer (MERIS) bands, in situ remote sensing reflectance was re-sampled to the bandwidth of 10 nm. The relationship between TSM and re-sampled R (rs) at 620 nm (MERIS band 6) and 665 nm (MERIS band 7) are obtained (R(2) = 0.748, RMSE = 1.697 mg L(?-?1), MRE = 8.785%, n = 13). Additionally, to map the spatial distribution of TSM in the PRE, MERIS level_1B data were calibrated using a multiple linear regression model based on in situ R (rs). Another dataset collected in the ...

2010-09-01

43

Sizes, graphitic structures and fractal geometry of light-duty diesel engine particulates.  

Energy Technology Data Exchange (ETDEWEB)

The particulate matter of a light-duty diesel engine was characterized in its morphology, sizes, internal microstructures, and fractal geometry. A thermophoretic sampling system was employed to collect particulates directly from the exhaust manifold of a 1.7-liter turbocharged common-rail direct-injection diesel engine. The particulate samples collected at various engine-operating conditions were then analyzed by using a high-resolution transmission electron microscope (TEM) and an image processing/data acquisition system. Results showed that mean primary particle diameters (dp), and radii of gyration (Rg), ranged from 19.4 nm to 32.5 nm and 77.4 nm to 134.1 nm, respectively, through the entire engine-operating conditions of 675 rpm (idling) to 4000 rpm and 0% to 100% loads. It was also revealed that the other important parameters sensitive to the particulate formation, such as ...

2003-01-01

44

Synthesis of ?-Al2O3 nanowires through a boehmite precursor route  

British Library Electronic Table of Contents (United Kingdom)

Crystalline ?-Al2O3 nanowires with diameter, 20?40?nm, length above 600?nm and aspect ratio above 30 have been successfully synthesized by thermal decomposition of boehmite (?-AlOOH) precursors obtained via hydrothermal route by using AlCl3, NaOH and NH3 as starting materials. Thermogravimetric analysis (TG), differential thermal analysis (DTA), X-ray diffraction (XRD), transmission electron microscope (TEM), selected area electron diffraction (SAED) and high resolution transmission electron microscope (HRTEM) were used to characterize the features of the as-made ?-Al2O3 nanowires and their ?-AlOOH precursors. The pH value of the solution and the mixed precipitant play important roles in the formation of ?-AlOOH nanowires. After calcination at 500?C for 2?h, the orthorhombic ?-AlOOH transf...

2011-01-01

45

Laser stabilization at 1536 nm using regenerative spectral hole burning  

International Nuclear Information System (INIS)

Laser frequency stabilization giving a 500-Hz Allan deviation for a 2-ms integration time with drift reduced to 7 kHz/min over several minutes was achieved at 1536 nm in the optical communication band. A continuously regenerated spectral hole in the inhomogeneously broadened "4I_1_5_/_2(1)#->#"4I_1_3_/_2(1) optical absorption of an Er"3"+:Y_2SiO_5 crystal was used as the short-term frequency reference, while a variation on the locking technique allowed simultaneous use of the inhomogeneously broadened absorption line as a long-term reference. The reported frequency stability was achieved without vibration isolation. Spectral hole burning frequency stabilization provides ideal laser sources for high-resolution spectroscopy, real-time optical signal processing, and a range of applications requiring ultra-narrow-band light sources or coherent detection; the time scale for stability and the compatibility with spectral hole burning devices make ...

2001-04-15

46

Focused ion beam machined nanostructures depth profiled by macrochannelling ion beam analysis  

International Nuclear Information System (INIS)

High aspect ratio sub-#mu#m periodic structures fabricated by focused ion beam (FIB) lithography have been characterised by Rutherford backscattering spectrometry (RBS) using the macrochannelling technique. The technique overcomes the limitations of complementary techniques such as scanning electron microscopy (SEM) and atomic force microscopy (AFM), which can provide images with sub-#mu#m resolution of just the surface features and not of the deep sub-surface structures, without destructive cross sectioning of the sample. Here RBS macrochannelling with a 2 MeV He"+ ion beam is used to analyse a diffraction grating fabricated by FIB milling an array of 100 nm wide trenches in a 300 nm thick Ag film on a Si substrate. Using the surface structure imaged by SEM and AFM as a starting point, a numerical model for the RBS spectrum from the grating is fitted to the experimental spectrum as a function of the sub-surface structure. ...

2006-08-01

47

Fabrication of nanometer structures by means of a fine-focused ion beam  

International Nuclear Information System (INIS)

Focused Ion Beams are an important approach for nanostructure fabrication in the semiconductor industry and material sciences. Applications in sputtering and ion induced deposition of materials are investigated. The IMSA FIB system equipped with the high resolution Orsay Physics CANION M31plus ion column with current densities up to 10 A/cm"2 including a gas injection system is applied. In this work the ion beam induced chemical vapour deposition of tungsten, wherefore tungsten hexacarbonyl as precursor gas is used for a first investigation. Conductive tungsten-nanowires with smallest cross-section upon a substrate of Si and SiO_2 are produced. The ion beam parameters of this focused ion beam system are optimized for the metal deposition. A short insight in the theory of layer nucleation and growth induced by the ion beam during the metal deposition is given. The layer quality is determined by Auger electron analysis which shows the components in atomic percent ...

2000-03-01

48

Crystal growth, structural and optical characterization of a semi-organic single crystal for frequency conversion applications  

International Nuclear Information System (INIS)

Single crystals of semi-organic L-histidine hydrobromide have been grown by slow evaporation technique from a mixture of L-histidine and hydrobromic acid in aqueous solution at ambient temperature. From high-resolution X-ray diffraction analysis, the crystalline perfection of the grown crystal has been studied. Single crystal X-ray diffraction analyses, Nuclear Magnetic Resonance spectral analysis, Thermo-Gravimetry (TG), Differential Thermal Analysis (DTA) and hardness test have been employed to characterize the as-grown crystals. The UV cutoff wavelength of the grown crystal is below 300 nm and has a wide transparency window, which is suitable for second harmonic generation of laser in the blue region. Nonlinear optical characteristics have been studied using Q switched Nd:YAG laser (#lambda#=1064 nm). The second harmonic generation conversion efficiency of the grown crystals confirms their suitability for frequency ...

2010-12-15

49

Synthesis and characterization of Co-Ag core-shell nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

A micellar method has been used to prepare silver-coated cobalt (Co-Ag) nanoparticles. The synthesized particles have been deeply characterized by several methods, i.e., XRD, UV-Vis, TEM, XPS, and electrochemical techniques. There is every indication that the obtained particles show a truly core-shell structure. All the nanoparticles obtained under different conditions are in the size range 3-5 nm. High-resolution TEM (HRTEM), Fast Fourier Transformation (FFT), and Selected Area Electron Diffraction (SAED) indicated that the presence of hcp-Co and fcc-Ag, in which cobalt is located in the central area; meanwhile silver is at the edges of the nanoparticle. The absorption band of the Co-Ag colloid shifts to a longer wavelength and broadens relative to that of pure silver colloid. Voltammetric characterization allowed to determine the coverage of the cobalt core.

2010-08-15

50

Silver nanoparticles prepared by chemical reduction-protection method, and their application in electrically conductive silver nanopaste  

Energy Technology Data Exchange (ETDEWEB)

Ag nanoparticles were prepared in a water-phase system with a mixture of silver-ammonia complex, sodium borohydride, and lauric acid according to molar feed ratio of approximately 6:3:1. The mechanism of preparation and separation by chemical reduction-protection method was explored. The as-synthesized Ag nanoparticles were characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD) and UV-vis spectroscopy, respectively. It was found that the size of high purity Ag particles was ranging from 30 to 50 nm with slight agglomeration. In addition, the as-synthesized wet Ag nanoparticles were dispersed stably in organic vehicle to formulate electrically conductive nanopaste. Upon direct-written and sintered, the array pattern of the nanopaste with the resolution of about 30 {mu}m was achieved with the electrical resistivity in the order of magnitude of 10{sup -5} {Omega} cm.

2010-04-02

51

Non-destructive Imaging of Individual Bio-Molecules  

CERN Document Server

Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.

2009-01-01

52

Nanostructured nickel ferrite: A liquid petroleum gas sensor  

British Library Electronic Table of Contents (United Kingdom)

The present investigation deals with the synthesis of nanostructured nickel ferrite (NiFe2O4) and their liquid petroleum gas-sensing characteristics. The 15-20nm size nickel ferrite has been synthesized at 700degreeC by a simple molten-salt route using sodium chloride as grain growth inhibitor. These nanoparticles exhibit significantly high response towards liquid petroleum gas (LPG) in comparison with ethanol vapor, hydrogen sulfide, ammonia and hydrogen. The gas response towards various gases at their 200ppm concentrations is investigated at 200-450degreeC. Different characterization techniques have been employed, such as differential thermal analysis, X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and high resolution transmission elec...

2009-01-01

53

A high sensitivity two-color interferometer for pulsed power plasmas  

International Nuclear Information System (INIS)

A high sensitivity, high bandwidth, two-color interferometer (1064 and 532 nm) has been tested on the Hawk pulsed power generator at the Naval Research Laboratory. The phase resolution is 10"-"5 waves with a rise time of 3 ns, a new capability for diagnosing plasmas, and neutrals in pulsed power experiments. The two-color feature is used to distinguish phase shifts from free (plasma) electrons and bound (neutral and ion) electrons. Simultaneous electron and neutral density measurements were demonstrated in a plasma opening switch (POS) experiment. The ability to measure small phase shifts with fast rise time were demonstrated in a plasma filled diode experiment. The high sensitivity and vibration isolation enable neutral gas distribution measurements from supersonic nozzles used in plasma radiation source experiments. Examples of these measurements and future applications are described. copyright 1997 American Institute of Physics.

54

Recent neutron scattering work at the University of Lowell  

International Nuclear Information System (INIS)

Neutron elastic and inelastic scattering cross sections of _2_3_8U and _2_3_2Th have been measured at the University of Lowell for states below 1.8 MeV. A time-of-flight (TOF) spectrometer was used. The disc-shaped scatterer was oriented to optimize energy resolutions for 200-to-500-keV neutrons. Neutrons were obtained via the _7Li(p,n)_7Be reaction. Targets were prepared by in-situ evaporation of Li onto a Ta backing. During the evaporation, the target thickness was monitored using a 5-m-flight-path TOF spectrometer; a typical target had a neutron thickness from 8 to 10 keV for Esub(p) = 2.25.MeV. Spectra were analyzed using the unfolding code TINA; standard peak shapes were obtained from codes LAGUE and LAPA. Results obtained will be presented.

1981-11-23

55

Plasma dynamics in the PF-1000 device under full-scale energy storage: II. Fast electron and ion characteristics versus neutron emission parameters and gun optimization perspectives  

International Nuclear Information System (INIS)

Electron and ion beam dynamics of the PF-1000 facility were investigated for the first time at its upper energy limit (?1 MJ) in relation to neutron emission, the pinch's plasma ('target') characteristics and some other parameters with the help of a number of diagnostics with ns temporal resolution. Special attention was paid to the temporal and the spatial cross correlations of different phenomena. Results of these experiments are in favour of a neutron emission model based on ion beam-plasma interaction with three important features: (1) the plasma target is hot and confined during a few 'inertial confinement times'; (2) the ions of the main part of the beam are magnetized and entrapped around the pinch plasma target for a period longer than the characteristic time of the plasma inductive storage system and (3) ion-ion collisions (both fusion collisions, due to head-on impacts and Coulomb collisions) ...

2007-06-21

56

Fabrication and characterization of low aberration micrometer-sized electron lenses.  

Science.gov (United States)

Intrinsic spherical aberrations of electron lenses have been the major resolution limiting factor in electron microscopes for several decades. While effective correctors have recently been implemented, an alternative to correct these aberrations is to circumvent them by scaling down lens dimensions by several orders of magnitude. We have fabricated electrostatic lenses exhibiting one micrometer diameter apertures and evaluated their beam forming properties against predictions from numerical ray tracing simulations. It turns out that it is routinely possible to shape a paraxial low-energy electron beam by such micron-sized lenses. Beam profiles have been measured both at a distant detector as well as in a plane close to the lens. It is shown that the lens can form a parallel beam extending no more than 800 nm from the optical axes at a distance of 200 microm beyond the lens exit. We believe that these findings constitute a prerequisite to derive ...

2010-04-24

57

Effect of alcohols and temperature on the direct chiral resolutions of fipronil, isocarbophos and carfentrazone-ethyl.  

Science.gov (United States)

The enantiomeric separations of three pesticides fipronil (asymmetric nitrogen), isocarbophos (asymmetric phosphorus) and carfentrazone-ethyl (asymmetric carbon) were studied on cellulose-tri(3,5-dimethylphenylcarbamate) chiral stationary phase using high-performance liquid chromatography under normal phase. The mobile phase was n-hexane with alcohols including ethanol, n-propanol, iso-propanol, n-butanol and iso-butanol as polar modifiers. The flow rate was 1.0 mL/min with UV detection at 280, 225 and 230 nm for fipronil, isocarbophos and carfentrazone-ethyl respectively. The influence of the modifiers and their volume content and temperature from 0 to 50 degrees C on the separations was investigated. The chiral stationary phase showed excellent stereoselectivity for the two enantiomers of fipronil and isocarbophos and certain chiral recognition for carfentrazone-ethyl. Iso-propanol was more suitable for the chiral separation of isocarbophos and ...

2005-07-01

58

Reactive magnetron sputtering of hard Si-B-C-N films with a high-temperature oxidation resistance  

International Nuclear Information System (INIS)

Based on the results obtained for C-N and Si-C-N films, a systematic investigation of reactive magnetron sputtering of hard quaternary Si-B-C-N materials has been carried out. The Si-B-C-N films were deposited on p-type Si(100) substrates by dc magnetron co-sputtering using a single C-Si-B target (at a fixed 20% boron fraction in the target erosion area) in nitrogen-argon gas mixtures. Elemental compositions of the films, their surface bonding structure and mechanical properties, together with their oxidation resistance in air, were controlled by the Si fraction (5-75%) in the magnetron target erosion area, the Ar fraction (0-75%) in the gas mixture, the rf induced negative substrate bias voltage (from a floating potential to -500 V) and the substrate temperature (180-350 deg. C). The total pressure and the discharge current on the magnetron target were held constant at 0.5 Pa and 1 A, respectively. The ...

2005-11-01

59

Turnover of texture in low rate sputter-deposited nanocrystalline molybdenum films  

International Nuclear Information System (INIS)

The crystallite size and orientation in molybdenum films prepared by magnetron sputtering at a low rate of typical 1 (angstrom)s and a pressure of 0.45 Pa was investigated by X-ray diffraction and texture analysis. The surface topography was studied using atomic force microscopy. Increasing the film thickness from 20 nm to 3 microm, the films show a turnover from a (110) fiber texture to a (211) mosaic-like texture. In the early state of growth (20 nm thickness) the development of dome-like structures on the surface is observed. The number of these structures increases with film thickness, whereas their size is weakly influenced. The effect of texture turnover is reduced by increasing the deposition rate by a factor of six, and it is absent for samples mounted above the center of the magnetron source. The effect of texture turnover is related to the bombardment of the films with high energetic argon neutrals resulting from backscattering at the ...

1997-04-04

60

Surface morphology of thin lysozyme films produced by matrix-assisted pulsed laser evaporation (MAPLE)  

Energy Technology Data Exchange (ETDEWEB)

Thin films of the protein, lysozyme, have been deposited by the matrix-assisted pulsed laser evaporation (MAPLE) technique. Frozen targets of 0.3-1.0 wt.% lysozyme dissolved in ultrapure water were irradiated by laser light at 355 nm with a fluence of 2 J/cm{sup 2}. The surface quality of the thin lysozyme films of different thickness deposited on 7 mm x 7 mm Si-<1 0 0>-wafers was investigated with scanning electron microscopy and atomic force microscopy. Already at comparatively low thickness, {approx}20 nm, the substrate is covered by intact lysozyme molecules and fragments. The concentration of lysozyme in the ice matrix apparently does not play any significant role for the morphology of the film. The morphology obtained with MAPLE has been compared with results for direct laser irradiation of a pressed lysozyme sample (i.e. pulsed laser deposition (PLD))

2007-12-15

61

Properties of ZnO thin films prepared by radio-frequency plasma beam assisted laser ablation  

International Nuclear Information System (INIS)

Zinc oxide thin films were obtained by laser ablation of a Zn target in oxygen reactive atmosphere, the oxygen being supplied either by a standard gas inlet valve or from a radio-frequency (rf) oxygen plasma. Pt-coated silicon and MgO were used as substrates. The influence of the deposition parameters as laser wavelength (266, 355, 1064 nm), laser fluence (1.5-20 J/cm2) and oxygen pressure (1-60 Pa) was studied. The influence of the rf plasma beam addition on the morphological proprieties of zinc oxide films was particularly investigated, simultaneously with several configurations of the direction of the ablation plasma, the rf plasma beam and the substrate. The obtained films, with thicknesses in the range of 50 nm to 1 ?m have been characterized by atomic force microscopy (AFM), X-ray diffraction (XRD), transmission electron microscopy (TEM).

2005-07-15

62

Uranium isotopic assay instrument  

International Nuclear Information System (INIS)

Full text: The isotopic assay instrument under development at Pacific Northwest National Laboratory (PNNL) is capable of rapid prescreening to detect small and rare particles containing high concentrations of uranium in a heterogeneous sample. The isotopic measurement concept is based on laser vaporization of solid samples followed by sensitive isotope-specific detection using either uranium atomic fluorescence emission or uranium atomic absorbance. Both isotopes are measured concurrently, following a single ablation laser pulse using two external-cavity violet diode lasers. The simultaneous measurement of both isotopes enables the correlation of the fluorescence and absorbance signals on a shot-to-shot basis. This measurement approach demonstrated negligible channel crosstalk between isotopes. Scanning the heterogeneous samples provides high-resolution imagery of sample isotopic fluorescence and absorbance. Isotopically selective excitation of uranium vapor also ...

2006-10-16

63

Large Scale Laser Two-Photon Polymerization Structuring for Fabrication of Artificial Polymeric Scaffolds for Regenerative Medicine  

Science.gov (United States)

We present a femtosecond Laser Two-Photon Polymerization (LTPP) system of large scale three-dimensional structuring for applications in tissue engineering. The direct laser writing system enables fabrication of artificial polymeric scaffolds over a large area (up to cm in lateral size) with sub-micrometer resolution which could find practical applications in biomedicine and surgery. Yb:KGW femtosecond laser oscillator (Pharos, Light Conversion. Co. Ltd.) is used as an irradiation source (75 fs, 515 nm (frequency doubled), 80 MHz). The sample is mounted on wide range linear motor driven stages having 10 nm sample positioning resolution (XY--ALS130-100, Z--ALS130-50, Aerotech, Inc.). These stages guarantee an overall travelling range of 100 mm into X and Y directions and 50 mm in Z direction and support the linear scanning speed up to 300 mm/s. By moving the sample three-dimensionally the position of ...

2010-11-10

64

Apoferritin-Templated Yttrium Phosphate Nanoparticle Conjugates for Radioimmunotherapy of Cancers  

Energy Technology Data Exchange (ETDEWEB)

We report a templated-synthetic approach based on apoferritin to prepare radionuclide nanoparticle (NP) conjugates. Non-radioactive yttrium (89Y) was used as model target and surrogate for radioyttrium (90Y) to prepare the nanoparticle conjugate. The center cavity and multiple channel structure of apoferritin offer a fast and facile method to precipitate yttrium phosphate by diffusing yttrium and phosphate ions into the cavity of apofrritin, resulting a core-shell nanocomposite. The yttrium phosphate/apoferritin nanoparticle was functionalized with biotin for further application. The synthesized nanoparticle was characterized by transmission electron microscopy (TEM) and x-ray photoelectron spectroscopy (XPS). We found that the resulting nanoparticles were uniform in size, with a diameter of around 8 nm. We tested the pre-targeting capability of the biotin-modified yttrium phosphate/apoferritin nanoparticle (yttrium ...

2008-05-01

65

Study of implantation damage in germanium formed using Ga"+ FIB  

International Nuclear Information System (INIS)

Full text: It is known that the ion implantation of germanium single crystals at room temperature results in drastic alteration of the germanium surface and the formation of cellular relief. Voids were found into the near-surface damage layer. The intersection of these voids with the germanium surface, as result of sputter etching, forms cellular relief. However, exact mechanism responsible for formation of the voids is not known. A 10 and 30 keV Ga"+ irradiation of Ge #left brace#100#right brace# crystal at room temperature was carried out using a focused ion beam (FIB) system with a dose in the range 0.5x10"1"2 to 1.5x10"1"4 ion/cm"2. The topology of the modified germanium surface and the structure of the radiation damage was studied using imaging facilities of the FIB systems and transmission electron microscopy. The strong cellular structure of Ge was observed after an ion dose of 3x10"1"3 ion/cm"2. High-resolution TEM showed a complex structure of the ...

66

Focused ion beam lithography for rapid prototyping of metallic films  

International Nuclear Information System (INIS)

We present FIB-lithography methods for rapid and cost-effective prototyping of metal structures covering the deep-submicron- to the millimeter-range in a single lithography cycle. Focused ion beam (FIB) systems are widely used in semiconductor industry and research facilities for both analytical testing and prototyping. A typical application is to apply electrical contact to micron-sized sensors/particles by FIB induced metal deposition. However, as for E-beam lithography, patterning times for large area bonding pads are unacceptably long, resulting in cost-intensive prototyping. In this work, we optimized FIB lithography processing for negative and positive imaging mode to form metallic structures for large-areas down do the sub-100 nm range. For negative lithography features are defined by implanting Ga"+-ions into a commercial photo resist, without affecting the underlying structures by impinging ions. The structures are highly suitable for following lift-off ...

2010-03-21

67

Determination of Cinchona alkaloids and Vitamin B_6 by high-performance liquid chromatography with fluorescence detection  

International Nuclear Information System (INIS)

A simple and specific method has been developed for the simultaneous determination of the four major Cinchona alkaloids and their dihydroderivatives and pyridoxine hydrochloride (Vitamin B_6) by high-performance liquid chromatography (HPLC) with fluorescence detection (#lambda#_e_m=420 nm with #lambda#_e_x=330 nm). The chromatographic separation was performed on a Phenomenex Prodigy ODS column (5 #mu#m, 250 mmx3.2 mm i.d.), recommended for basic compounds, under isocratic reversed-phase conditions. The method allowed a good peak shape and an effective resolution of the tested compounds. The extraction of alkaloids from the Cinchona succirubra bark was carried out in mild and fast conditions (ambient temperature, 20 min) by ultrasonication. The procedure showed to be advantageous respect to a reference method, which involved Soxhlet extraction. The results were compared statistically by means of the Student's t-test and the ...

2004-06-04

68

High resolution electron microscopy of interfaces in fcc materials  

Energy Technology Data Exchange (ETDEWEB)

Modern high-resolution electron microscopy (HREM) instruments, which are capable of a point-to-point resolution of better than 0.2 nm, have allowed atomic-scale observations of a variety of internal interfaces. The application of the HREM technique to fcc model systems for the purpose of addressing a number of interface issues will be examined in this paper. Atomic structure observations for heterophase interfaces of metal/metal and metal/metal-oxide systems as well as HREM studies of grain boundaries in NiO and Au will be discussed with emphasis on generic structural features and the role of the interface plane. Comparisons between observed interface structures and atomistic computer modeling results have shown agreements for some interfaces, as well as certain differences in others. A number of structural features are common to both metal and oxide grain boundaries, as well as certain heterophase boundaries. Of particular ...

1990-08-01

69

Focused ion beam assisted three-dimensional rock imaging at submicron scale  

Energy Technology Data Exchange (ETDEWEB)

Computation of effective flow properties of fluids in porous media based on three dimensional (3D) pore structure information has become more successful in the last few years, due to both improvements in the input data and the network models. Computed X-ray microtomography has been successful in 3D pore imaging at micron scale, which is adequate for many sandstones. For other rocks of economic interest, such as chalk and diatomite, submicron resolution is needed in order to resolve the 3D-pore structure. To achieve submicron resolution, a new method of sample serial sectioning and imaging using Focused Ion Beam (FIB) technology has been developed and 3D pore images of the pore system for diatomite and chalk have been obtained. FIB was used in the milling of layers as wide as 50 micrometers and as thin as 100 nanometers by sputtering of atoms from the sample surface. The focused ion beam, consisting of gallium ions (Ga+) accelerated by ...

2003-05-09

70

Failure analysis and defect review using extended accuracy of the CrossBeam {sup registered} Technology  

Energy Technology Data Exchange (ETDEWEB)

The use of the focused ion beam (FIB) systems has increased to a high level in recent years. The imaging, milling, and deposition capabilities of the FIB make it the ideal instrument for e.g., site-specific failure analysis, specimen preparation and nano-machining. Ion channelling contrast allows for selective imaging of polycrystalline and polyphase microstructures. In addition, the FIB and CrossBeam registered instruments are unique stand-alone analytical tools. Their vast capabilities have enabled numerous applications into the semiconductor and materials sciences applications. These integrated CrossBeam registered Tools enable the observation and direct control of the FIB operation in real time. In addition to the improved accuracy and resolution the electron beam adds analytical capabilities as STEM, EDS and EBSP to the instruments. To ensure a safe and reliable operation of the instrument, a dedicated vacuum system is needed. This type of instrument combines ...

2005-07-01

71

Social Skills Training for Taiwanese Students at Risk for Emotional and Behavioral Disorders  

Science.gov (United States)

Two third-grade Taiwanese students at risk for emotional and behavioral disorders participated in a pull-out, small-group social skills training program developed to promote their skill acquisition and maintenance. Using a multiple baseline across skills design, the authors demonstrated that both participants made marked performance improvement in all three targeted social skills of on-task, appropriate conflict resolution, and cooperation during the intervention condition. Maintenance and follow-up data showed that both participants sustained their use of taught social skills in the training setting and their third-grade classroom, respectively. Social validity measures, including peer sociometric ratings and consumer satisfaction questionnaires and interviews, supported the positive effects of the social skills training program for both participants. Implications for research and practice are discussed. (Contains 2 tables and 2 figures.)

2010-09-01

72

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac applications together with the ...

2009-03-01

73

Neutrino cross sections with the MINER?A Experiment  

British Library Electronic Table of Contents (United Kingdom)

MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...

2011-01-01

74

A modular neural network for direction-of-arrival estimation of two sources  

British Library Electronic Table of Contents (United Kingdom)

This work addresses the problem of estimating the direction-of-arrival (DOA) of two sources using an array of sensors. This problem is mostly useful in radar applications, where we have few targets at each range bin. Super-resolution algorithms, such as maximum likelihood (ML) estimation and multiple signal classification (MUSIC), have been applied to this problem, but the former involves high computation efforts, while the later has poor estimation performance for coherent sources. In this work, we propose a DOA estimation network, named RBF-AML, which combines the approximated ML (AML) estimator and a radial basis function (RBF) neural network (NN). In the proposed RBF-AML network, the entire two dimensional DOA space is divided into multiple sectors covered by RBF experts. The AML funct...

2011-01-01

75

Complexity of the microstructure evolution for optimization cBN growth in a four-step ion-assisted deposition process  

International Nuclear Information System (INIS)

The changes in microstructure of a specially prepared boron nitride (BN) film as a function of film depth were studied by high resolution transmission electron microscopy (HRTEM) and other materials analysis tools. These changes were then correlated to the changes in processing parameters during film growth. The analyzed film was fabricated by the four-step ion-assisted deposition procedure known to be effective in film-stress engineering for the formation and retention of a thick cubic BN (cBN) layer with a three-step buffer-layer deposition. In this deposition, the energy of the ions assisting cBN formation was increased stepwise from 200 to 280, and then to 360 eV [S.F. Wong, C. W. Ong, G.K.H. Pang, K.Z. Baba-Kishi, W. M. Lau, J. Vac. Sci. Technol. A 22 (2004) 676]. The nominal thickness of the cBN layer was 650 nm and that for each of the three buffer layers was about 160 nm. Both the HRTEM and electron diffraction ...

2005-10-01

76

X-ray production with sub-picosecond laser pulses  

Energy Technology Data Exchange (ETDEWEB)

The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.

1993-12-31

77

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. ...

1996-12-01

78

The pisa experiment: spallation products identified by bragg curve spectroscopy  

International Nuclear Information System (INIS)

In the framework of spallation neutron sources and accelerator-driven systems, the international PISA (Proton-induced Spallation) collaboration has initiated measurements of total- and double-differential cross-sections for products of spallation reactions in a wide range of target nuclei (GU) at the COSY proton accelerator in Julich (Germany). The purpose is to study secondary particle production created in structural, window and target materials via proton beams up to 2.5 GeV of incident kinetic energy. Residual nuclei [H, He up to intermediate mass fragment (IMF)] production cross-sections are of great importance for estimating the damage to target and structure materials involving the planned spallation neutron sources, given that the lifetime of window and target materials is directly associated to those cross-sections. The demand for reliable theoretical predictions on production cross-sections is ...

2004-05-17

80

Constraints on target chamber first wall and target designs that will enable NIF debris shields to survive  

CERN Document Server

Constraints on target chamber first wall and target designs that will enable NIF debris shields to survive

1999-01-01

81

X-ray microanalysis of Al/Zr multilayers in the transmission electron microscope  

International Nuclear Information System (INIS)

A one-nanometer scale transmission electron microscope electron probe X-ray microanalysis characterization of as-deposited and annealed aluminum--11.5 at.% zirconium multilayer samples in cross-section synthesized by magnetron sputtering is reported on here. Composition line profiles were acquired across Zr layers in as-deposited material and samples isochronally annealed in a differential scanning calorimeter to temperatures of 290 C and 485 C. A spatial resolution of approximately 1.5 to 2.0 nm was achieved in these experiments and will be improved by deconvolution of the instrumental electron probe function from the data. The as-deposited structure consisted of crystalline Al and Zr layers with thin amorphous layers at the Al/Zr interfaces. The amorphous interface layers increased in thickness upon annealing to 290 C. Additionally, at 290 C a metastable cubic alloy forms at the Zr deposited on Al interface. Upon heating to 485 C a multilayer ...

1997-04-04

82

Superfluid 4He interferometer operating near 2 K  

International Nuclear Information System (INIS)

We report the observation of quantum interference in superfluid 4He. The interferometer, an analog of a dc-superconducting quantum interference device (SQUID), employs a recently reported phenomenon wherein superfluid 4He exhibits Josephson frequency oscillations in an array of submicron apertures. An interference pattern is generated by reorienting the loop of the superfluid 'SQUID' with respect to the Earth's rotation vector, thereby varying the rotation flux in the loop. The experiment is performed at 2 K, a temperature 2000 times higher than previously achieved with superfluid 3He. We find that the interference exists not only when the aperture array current-phase relation is a sinusoidal function characteristic of the Josephson effect, but also at lower temperatures where it is linear and oscillations occur by phase slips. The modest requirements for the interferometer (2 K cryogenics and fabrication of apertures at the level of 100 nm) and its potential ...

2006-09-01

83

Ni, Pd, and Pt on GaAs: A comparative study of interfacial structures, compositions, and reacted film morphologies  

Energy Technology Data Exchange (ETDEWEB)

The reactions between (100) GaAs and the near-noble metals Ni, Pd, and Pt have been investigated by application of high-resolution transmission electron microscopy (TEM), energy-dispersive analysis of x rays in the scanning TEM and Rutherford backscattering spectrometry. Emphasis is placed on the evolution of the phase distributions, film compositions, and interface morphologies during annealing at temperatures up to 480 /sup 0/C. The first phase in the Ni/GaAs reaction is shown to have the nominal composition Ni/sub 3/GaAs. Ternary phases of the type Pd/sub x/GaAs are also found to be the dominant products of the Pd/GaAs reaction. Conversely, only binary phases result from the Pt/GaAs reaction. These observations are used to construct isothermal sections of the M--Ga--As thin-film phase diagrams. The behavior of a thin (1--2 nm) native oxide--hydrocarbon layer during the Ni/GaAs, Pd/GaAs, and Pt/GaAs reactions is also investigated. Only the ...

1987-03-01

84

Laser induced local and periodic phase transformations in iron oxide thin films obtained by chemical vapour deposition  

International Nuclear Information System (INIS)

Iron oxide films have been deposited on Si(100) substrates by chemical vapour deposition (CVD) of iron(III) tert-butoxide ([Fe(O "tBu)_3]_2) in the temperature range 350-450 deg. C. The precursor flux and substrate temperature were varied to control the phase composition, average grain size and film thickness. The nature of substrate and deposition temperature markedly influence the morphology and iron-oxygen stoichiometry in the CVD deposits. Phase transformations in iron oxide films were achieved through precise local and periodic heating of the films by interfering laser beams. The interaction of iron oxide films with short laser pulses (Nd:YAG, 355 nm) induced partial transformation of hematite (#alpha#-Fe_2O_3) to magnetite (Fe_3O_4) or magnetite to wuestite (Fe_1_-_xO), respectively. The phase characterization and morphology of the hematite and magnetite films were investigated before and after laser irradiation by X-ray diffractometry, high ...

2005-07-15

85

Energy-filtered electron microscopy for imaging core-shell nanostructures  

Energy Technology Data Exchange (ETDEWEB)

CuAg core-shell nanoparticles are synthesized by ultra-high vacuum thermal evaporation. We show on this system how the Energy-Filtered Transmission Electron Microscopy (EFTEM) technique allows one to improve the characterization by precisely pointing out the formation of core-shell arrangements in bimetallic nanoparticle assemblies. A criterion to measure the shell thickness from EFTEM images on unique core-shell nanoparticles is defined, that can be used for core-shell nanoparticles of any sizes, with shell thicknesses over 1 nm. It is based on the intensity variation along a line drawn across a core-shell nanoparticle on a EFTEM image. This criterion has been validated by a close comparison of the shell thickness measurements performed in this work and the ones obtained by acoustic micro-Raman spectroscopy. Using this criterion, we report a strong correlation between the size of the Cu cores and the formation of the core-shell arrangements in the nanoparticle ...

2008-08-15

86

Land Cover Classification Comparison with Different Resolution ...  

Science.gov (United States)

Dec 9, 2005 ... Classification of high resolution imagery is not as straightforward as more ... The challenges of classifying high resolution imagery stems ...

87

Surfactant based sol-gel approach to nanostructured LiFePO{sub 4} for high rate Li-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

Porous nanostructured LiFePO{sub 4} powder with a narrow particle size distribution (100-300nm) for high rate lithium-ion battery cathode application was obtained using an ethanol based sol-gel route employing lauric acid as a surfactant. The synthesized LiFePO{sub 4} powders comprised of agglomerates of crystallites <65nm in diameter exhibiting a specific surface area ranging from 8m{sup 2}g{sup -1} to 36m{sup 2}g{sup -1} depending on the absence or presence of the surfactant. The LiFePO{sub 4} obtained using lauric acid resulted in a specific capacity of 123mAhg{sup -1} and 157mAhg{sup -1} at discharge rates of 10C and 1C with less than 0.08% fade per cycle, respectively. Structural and microstructural characterization were performed using X-ray diffraction (XRD), scanning electron microscopy (SEM) and high-resolution transmission electron microscopy (HRTEM) with energy dispersive X-ray (EDX) analysis while ...

2007-01-01

88

Structure and magnetic properties of nanostructural strontium ferrite prepared by mechanochemical treatment  

International Nuclear Information System (INIS)

Full text: It was recently-established for hexagonal barium ferrite-industrially important magnetically hard material that refinement of the crystallite dimensions into the nanoscale regime, typically #<=# 10 nm, leads after heat treatment at temperatures 800-1000 deg C to significant coercivity increase of up to 6.5 kOe (#approx#3-4 times) with saturation magnetisation values of 50-55 emu/g (#approx#95% of bulk at room temperature). High-energy mechanochemical processing has been applied to prepare nanostructural (nanocrystalline-amorphous) composites. High resolution electron microscopy studies reveal that the enhancement of the final magnetic properties was due to formation of magnetically noninteracting #approx#l,#mu#m Ba-ferrite particles with 5-10 nm amorphous surface layer - depending on annealing parameters. Similar situation was established also for ball milled strontium ferrite (SrFe_1_2O_1_9) powders where ...

89

Amplified spontaneous emission from ZnO in n-ZnO/ZnO nanodots-SiO_2 composite/p-AlGaN heterojunction light-emitting diodes  

International Nuclear Information System (INIS)

This study demonstrates amplified spontaneous emission (ASE) of the ultraviolet (UV) electroluminescence (EL) from ZnO at #lambda##approx#380 nm in the n-ZnO/ZnO nanodots-SiO_2 composite/p- Al_0_._1_2Ga_0_._8_8N heterojunction light-emitting diode. A SiO_2 layer embedded with ZnO nanodots was prepared on the p-type Al_0_._1_2Ga_0_._8_8N using spin-on coating of SiO_2 nanoparticles followed by atomic layer deposition (ALD) of ZnO. An n-type Al-doped ZnO layer was deposited upon the ZnO nanodots-SiO_2 composite layer also by the ALD technique. High-resolution transmission electron microscopy (HRTEM) reveals that the ZnO nanodots embedded in the SiO_2 matrix have diameters of 3-8 nm and the wurtzite crystal structure, which allows the transport of carriers through the thick ZnO nanodots-SiO_2 composite layer. The high quality of the n-ZnO layer was manifested by the well crystallized lattice image in the HRTEM picture and the ...

2009-04-22

90

815nm radiation from germicidal lamps  

International Nuclear Information System (INIS)

An investigation of the intensity of electromagnetic radiation at a wavelength of 185nm emitted by a General Electric mercury discharge, germicidal lamp is described. From the measurement of the transmission of light as a function of wavelength from 185nm to 360nm, it was concluded that this type of germicidal lamp does not produce any biological or chemical effects through the 185nm line; the intensity of the 185nm line transmitted by the lamp was less than 0.1% of that for the 254nm line. Consequently, there was no discernable ozone production. (U.K.).

91

Nanofocusing refractive X-ray lenses  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact ...

2010-02-05

92

A shockproof container for the transport and storage of fragile or reactive target foils  

CERN Document Server

A shockproof container for the transport and storage of fragile or reactive target foils

1971-01-01

93

Isotope shift measurements at the {sup 242{ital f}}Am fission isomer  

Energy Technology Data Exchange (ETDEWEB)

Isotope shift measurements have been performed for the {sup 242{ital f}}Am fission isomer with target production rates of only a few per second. The method is based on resonance ionization spectroscopy (RIS) in a buffer gas cell with radioactive decay detection of the ionization process (RADRIS). A relative isotope shift ratio X{sub {ital exp}}=IS{sup 242{ital f},241}/IS{sup 243,241}=41.7{plus_minus}0.9 has been measured for the 500.02 nm transition corresponding to a nuclear parameter A{sup 242{ital f},241}=(5.4{plus_minus}0.3) fm{sup 2}. A preliminary analysis of the quadrupole moment based on the deformed Fermi model of the nuclear charge distribution results in Q{sub 20}=35.9{plus_minus}1.1({sup +0.3}{sub {minus}0.7}) {sub model} eb. {copyright} 1995 {ital American} {ital Institute} {ital of} {ital Physics}

1995-04-01

94

Friction properties of WS{sub 2}/graphite fluoride thin films grown by pulsed laser deposition  

Energy Technology Data Exchange (ETDEWEB)

Graphite fluoride (CF{sub x}) is investigated as an additive for WS{sub 2} thin films to reduce its sensitivity to moisture. The films are grown onto hardened 440C stainless steel disks by pulsed laser deposition using the 248 nm line from an excimer laser. Substrate temperature and additive concentration are varied to control film chemistry and crystal structure. The effect of relative humidity (i.e., < 1 to 85% RH) on friction is evaluated. Coatings grown at RT from targets with a low concentration of CF{sub x} exhibit ultra-low friction (ULF) behavior in dry air (i.e., {mu} {<=} 0.01), but friction increases with RH. Mechanisms for the ULF behavior are proposed which suggest that further reductions in friction are possible. Films grown at 300 C or with higher concentrations of CF{sub x} are relatively insensitive to humidity, but have more typical friction coefficients ({mu} {<=} 0.04) in dry air. (orig.)

1995-12-01

95

Conversion of a plasma enhanced chemical vapor deposited silicon-carbon-nitride thin film at ultra-low temperature by oxygen plasma  

Energy Technology Data Exchange (ETDEWEB)

In this work we present an ultra-low temperature method for the oxidation of an amorphous silicon-carbide-nitride (SiCN) material. The SiCN is deposited on silicon substrates by plasma enhanced chemical vapor deposition using CH{sub 4}, SiH{sub 4}, and N{sub 2} chemistry. The physical and chemical properties are characterized for the as-deposited SiCN and post-oxidized films are discussed. The SiCN film is exposed to oxygen plasma, where it undergoes a chemical transformation into a binary SiO{sub 2} material system. A 1.7 nm/min oxidation rate is typical for this process and compares favorably to oxidation methods utilizing much higher temperatures. The substrate temperature remains extremely low throughout the oxidation process, T{sub s} < 200 deg. C. Changes in film stress, optical constants, film thickness, surface roughness, and film density are measured. Chemical analysis by X-ray photoelectron spectroscopy is reported for both the as-deposited and ...

2008-01-30

96

An Upper Limit on the Albedo of HD 209458b: Direct Imaging Photometry with the MOST Satellite  

CERN Document Server

We present space-based photometry of the transiting exoplanetary system HD 209458 obtained with the MOST (Microvariablity and Oscillations of STars) satellite, spanning 14 days and covering 4 transits and 4 secondary eclipses. The HD 209458 photometry was obtained in MOST's lower-precision Direct Imaging mode, which is used for targets in the brightness range $6.5 < V < 13$. We describe the photometric reduction techniques for this mode of observing, in particular the corrections for stray Earthshine. We do not detect the secondary eclipse in the MOST data, to a limit in depth of 0.053 mmag (1 \\sigma). We set a 1 \\sigma upper limit on the planet-star flux ratio of 4.88 x 10^-5 corresponding to a geometric albedo upper limit in the MOST bandpass (400 to 700 nm) of 0.25. The corresponding numbers at the 3 \\sigma level are 1.34 x 10^-4 and 0.68 respectively. HD 209458b is half as bright as Jupiter in the MOST bandpass. This low geometric ...

2006-01-01

97

Size and morphology of heavy-duty vehicle particle emissions; Raskaan ajoneuvokannan hiukkaspaeaestoen koko ja morfologia - HD-PM  

Energy Technology Data Exchange (ETDEWEB)

Formation of particles from heavy duty diesel and CNG vehicles was studied in laboratory conditions. PM, nano and soot mode particle emissions formed from buses of Euro 2-5 -emission levels were studied in relation to age and type approval characteristics of the vehicle. Characteristic particle emission factors from city driving were obtained by driving the buses on VTT's heavy duty chassis dynamometer applying the transient Braunschweig city cycle. The vehicles were a representative set of Euro 2 to 3 emission categories, supplemented with Euro 4-5 (EEV) -targeted CRT, CNG and DPF cars. Particle number emissions from Euro 4 to 5 buses were 1/100-1/1000 and mass emissions 1/10-1/100 of those of the current fleet. Particle emission from natural gas buses and after an advanced CRT trap contained almost entirely liquid < 60 nm nano particles, which will make filter mass based PM control very challenging in the near future. One ...

2006-10-15

98

Intermetallic Co-Al powder for nuclear applications  

International Nuclear Information System (INIS)

Intermetallic compounds based on the Al-Co system were synthesized by solid state method - mechanical alloying and their properties were investigated using XRD, SEM, and DSC. The powder was used to make new targets of irradiation for gamma sources in order to enhance the specific activity and to reduce the consumption of material. The intermetallic compound AlCo was formed in the first 4 hours of milling. After 8 hours of milling the medium size of crystallites were of 5.58 nm. This value decreases with the increase of milling time up to 3 nm, corresponding to the 28 hours of grinding. There was calculated and plotted the Gibbs function, #DELTA#_f"0, for the reaction of formation AlCo and Al_3Co from the Al-Co system. It had negative values over the entire range of temperatures for both investigated compounds. After 28 hours milling a phase composition was obtained as follows: 0.2% Al; 21%Co ; 55.5%AlCo; 23.3% Al_1_3Co_4. ...

2009-10-12

99

Theoretical modelling of X-ray fluorescence signals for different lunar compositions and dependence on solar activity  

British Library Electronic Table of Contents (United Kingdom)

We present a forward modelling technique for calculating the surface X-ray spectra for a variety of lunar terrains. Our calculations considered variations in solar fluxes from solar quiescent condition to large flare activity (M1 flare), and expected elemental concentrations in the target, as well as yield, instrumental, and viewing geometry parameters for X-ray induced fluorescence from the lunar surface. Additionally, we present estimates of anticipated XRF signals from prominent Ka lines observable by a collimated 14cm2 X-ray detector from a 100km lunar orbit with 20km spatial resolution. Our results show that Mg, Al and Si characteristic Ka lines can be observed for all solar conditions. The Ca Ka lines line can be differentiated from a fixed background during more energetic solar cond...

2010-01-01

100

Survey for Transiting Extrasolar Planets in Stellar Systems. II. Spectrophotometry and Metallicities of Open Clusters  

CERN Document Server

We present metallicity estimates for seven open clusters based on spectrophotometric indices from moderate-resolution spectroscopy. Observations of field giants of known metallicity provide a correlation between the spectroscopic indices and the metallicity of open cluster giants. We use \\chi^2 analysis to fit the relation of spectrophotometric indices to metallicity in field giants. The resulting function allows an estimate of the target-cluster giants' metallicities with an error in the method of \\pm0.08 dex. We derive the following metallicities for the seven open clusters: NGC 1245, [m/H]=-0.14\\pm0.04; NGC 2099, [m/H]=+0.05\\pm0.05; NGC 2324, [m/H]=-0.06\\pm0.04; NGC 2539, [m/H]=-0.04\\pm0.03; NGC 2682 (M67), [m/H]=-0.05\\pm0.02; NGC 6705, [m/H]=+0.14\\pm0.08; NGC 6819, [m/H]=-0.07\\pm0.12. These metallicity estimates will be useful in planning future extra-solar planet transit searches since planets may form more readily in metal-rich ...

2005-01-01

101

Measurements of K-shell x-ray production cross sections and K to L and M-shell radiative vacancy transfer probabilities for Nd, Eu, Gd, Dy and Ho at excitation with 59.5 keV photons in an external magnetic field  

International Nuclear Information System (INIS)

The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied magnetic field. ...

2006-06-19

102

Measurement of L X-ray fluorescence cross-sections for elements with 45 Z50 using synchrotron radiation at 8keV  

British Library Electronic Table of Contents (United Kingdom)

The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.

2011-01-01

103

Integration and Testing of the Micro-X Rocket Payload  

Science.gov (United States)

The Micro-X instrument is a rocket borne, X-ray imaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will observe the Puppis A supernova remnant. Future targets include the core of ...

2011-05-01

104

Hawaii Clean Energy Initiative Existing Building Energy Efficiency Analysis: November 17, 2009 - June 30, 2010  

Energy Technology Data Exchange (ETDEWEB)

In June 2009, the State of Hawaii enacted an Energy Efficiency Portfolio Standard (EEPS) with a target of 4,300 gigawatt hours (GWh) by 2030 (Hawaii 2009). Upon setting this goal, the Hawaii Clean Energy Initiative, Booz Allen Hamilton (BAH), and the National Renewable Energy Laboratory (NREL), working with select local stakeholders, partnered to execute the first key step toward attaining the EEPS goal: the creation of a high-resolution roadmap outlining key areas of potential electricity savings. This roadmap was divided into two core elements: savings from new construction and savings from existing buildings. BAH focused primarily on the existing building analysis, while NREL focused on new construction forecasting. This report presents the results of the Booz Allen Hamilton study on the existing building stock of Hawaii, along with conclusions on the key drivers of potential energy efficiency savings and on the steps necessary to attain ...

2010-06-01

105

Full Calculation of Clumpiness Boost factors for Antimatter Cosmic Rays in the light of \\LambdaCDM N-body simulation results  

CERN Document Server

Anti-proton and positron Galactic cosmic ray (GCR) spectra are among the key targets for indirect detection of dark matter (DM). The boost factors, corresponding to an enhancement of the signal|linked to the clumpiness properties of the dark matter distribution|, have been taken as high as thousands in the past. The dramatic impact of these boost factors for indirect detection of antiparticles, for instance with the PAMELA satellite or the coming AMS-02 experiment, asks for their detailed calculation. We take into account the state-of-the-art results of high resolution N-body dark matter simulations to calculate the most likely energy dependent boost factors|linked to the GCR propagation properties|, for anti-protons and positrons. The results from extreme, but still possible, configurations of the clumpy dark matter component is also discussed. Starting from the mass and space distributions of sub-halos, the anti-proton and positron ...

2007-01-01

106

"1"5"8Tm and "1"5"6Tm decays  

International Nuclear Information System (INIS)

These experiments were performed on the Isocele separator, on-line with the Orsay synchrocyclotron; thulium isotopes were produced by bombarding natural erbium targets with 150nA beam of 157MeV protons. Two Ge(Li) detectors, with resolution of 2.3 and 2.5keV at 1332keV used for #gamma#-ray measurements; conversion electron spectra were measured using a Si(Li) detector. #gamma# spectra, #gamma#-#gamma# coincidence and conversion electron measurements were sufficient to build the flow energy level schemes of the transitional "1"5"8Er and "1"5"6Er nuclei. On both nuclei several quasi rotational bands have been identified. These results are compared with other even erbium isotopes and with the neighboring N=88 and 90 isotones. Comparisons with predictions issued from some classical models are also performed: "1"5"8Er appears as a deformed nucleus very similar to "1"6"0Er and "1"6"2Er; on the other hand "1"5"6Er seems to be a soft vibrational ...

1976-01-01

107

Studies of nuclear processes at the Triangle Universities Nuclear Laboratory. Progress report, 1 September 1995--31 August 1996  

Energy Technology Data Exchange (ETDEWEB)

The Triangle Universities Nuclear Laboratory (TUNL)--a collaboration of Duke University, North Carolina State University, and the University of North Carolina at Chapel Hill--has had a very productive year. This report covers parts of the second and third year of a three-year grant between the US Department of Energy and the three collaborating universities. The TUNL research program focuses on the following areas: precision test of parity-invariance violation in resonance neutron scattering at LANSCE/LANL; parity violation measurements using charged-particle resonances in A = 20--40 targets and the A = 4 system at TUNL; chaotic behavior in the nuclei {sup 30}P and {sup 34}Cl from studies of eigenvalue fluctuations in nuclear level schemes; search for anomalies in the level density (pairing phase transition) in 1f-2p shell nuclei using GEANIE at LANSCE/LANL; parity-conserving time-reversal noninvariance tests using {sup 166}Ho resonances at Geel, ORELA, or ...

1996-09-01

108

Analysis of the Semileptonic Decay D0 --> anti-K0 pi- mu+ nu  

Energy Technology Data Exchange (ETDEWEB)

This thesis describes the analysis of the semileptonic decay D{sup 0} {yields} {bar K}{sup 0} {pi}{sup -} {mu}{sup +}{nu} using FOCUS data. FOCUS is a fixed target experiment at Fermilab that studies the physics of the charm quark. Particles containing charm are produced by photon-gluon fusion from the collision of a photon beam on a BeO target. The experiment is characterized by excellent vertex resolution and particle identification. The spectrometer consists of three systems for track reconstruction (two silicon systems and one multiwire proportional chamber system) and two magnets of opposite polarity. The polarity of the magnet is such that the events of e{sup +}e{sup -} pairs produced in the target (which constitutes the main background) travel through a central opening in the detectors without interactions. Particle momentum is measured from the deflection angle in the magnets. Three multicell ...

2004-11-01

109

Concepts of radiotherapy treatment planning  

International Nuclear Information System (INIS)

Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging ...

2000-12-01

111
113

Computational Challenges in miRNA Target Predictions: To Be or Not to Be a True Target?  

UK PubMed Central (United Kingdom)

All microRNA (miRNA) target—finder algorithms return lists of candidate target genes. How valid is that output in a biological setting? Transcriptome analysis has proven to be a useful approach...Full Text Available

2009-01-01

114
115

Report of the Geostatistical Analysis of High Resolution ...  

Science.gov (United States)

... The variogram analysis of the high resolution imagery has shown that although more spatial scales have been identified than from the SPOT image ...

1998-05-01

116

Studies on formation and structures of ultrafine Cu precipitates in Fe-Cu model alloys for reactor pressure vessel steels using positron quantum dot confinement in the precipitates by their positron affinity. JAERI's nuclear research promotion program, H11-034 (Contract research)  

Energy Technology Data Exchange (ETDEWEB)

Positron annihilation experiments on Fe-Cu model dilute alloys of nuclear reactor pressure vessel (RPV) steels have been performed after neutron irradiation in JMTR. Nanovoids whose inner surfaces were covered by Cu atoms were clearly observed. The nanovoids transformed to ultrafine Cu precipitates by dissociating their vacancies after annealing at around 400degC. The nanovoids and the ultrafine Cu precipitates are strongly suggested to be responsible for irradiation-induced embrittlement of RPV steels. Effects of Ni, Mn and P addition on the nanovoid and Cu precipitate formations were also studied. The nanovoid formation was enhanced by Ni and P, but suppressed by Mn. The Cu precipitates after annealing around 400degC were almost free from these doping elements and hence were pure Cu in the chemical composition. Furthermore the Fermi surface of the 'embedded' Cu precipitates with a body centered cubic crystal structure was obtained from two dimensional angular ...

2003-03-01

117

Physical and electrochemical characterization of CdS hollow microspheres prepared by a novel template free solution phase method  

International Nuclear Information System (INIS)

Novel CdS hollow microspheres have been successfully synthesized via a facile template-free solution-phase reaction from cadmium nitrate and thioacetamide precursors. The morphology of CdS hollow microspheres depends strongly on the ratio between the precursors, cadmium nitrate to thioacetamide ratio. The physical properties of the hollow microspheres have systematically been studied by different characterization methods. The stoichiometry of the hollow microspheres studied by the energy dispersive X-ray diffraction spectroscopy confirmed that the synthesized CdS hollow microspheres are nearly stoichiometric bulk like CdS. The morphology of the hollow microspheres studied by high resolution scanning electron microscopy and transmission electron microscopy observations showed that the CdS hollow microspheres of the size of 2.5 ?m have hollow structure and are constructed by several nanoparticles of the size between 30 and 40 nm. The UV-visible ...

2010-12-15

118

Modification of ink-jet paper by oxygen-plasma treatment  

International Nuclear Information System (INIS)

A study on oxygen-plasma treatment of ink-jet paper is presented. Paper was exposed to a weakly ionized, highly dissociated oxygen plasma with an electron temperature of 5 eV, a positive-ion density of 8 x 1015 m-3 and a density of neutral oxygen atoms of 5 x 1021 m-3. Optical emission spectroscopy (OES) was applied as a method for detection of the reaction products during the plasma treatment of the paper. OES spectra between 250 and 1000 nm were measured continuously during the plasma treatment. The wettability of the samples before and after the plasma treatment was determined by measuring the contact angle of a water drop. The appearance of the surface-functional groups was determined by using high-resolution x-ray photoelectron spectroscopy (XPS), while changes in the surface morphology were monitored with scanning electron microscopy (SEM). Already after 1 s of the plasma treatment the surface, which was originally hydrophobic, changed to ...

2007-06-21

119

Lifetime measurements of singlet ungerade states in isotopic molecular nitrogen  

International Nuclear Information System (INIS)

Full text: In the upper layers of the Earth's atmosphere, molecular nitrogen absorbs the extreme ultraviolet (XUV) solar radiation. The absorption is associated with dipole-allowed excitation of states of singlet ungerade symmetry ("1#SIGMA#"+_u and "1#PI#_u), which are known to undergo predissociation due to coupling with a mainfold of "1#PI#_u states. We determined new N_2 isotopic lifetimes of many "1#SIGMA#"+_u and "1#PI#_u states via line broadening measurements in the frequency domain. Ultrahigh resolution XUV + UV ionization spectra were recorded (bandwidth #approx# 250 MHz, resolving power 10"7), from which the natural linewidth, i.e. lifetime, was determined. These lifetimes provide new information about the predissociation of the singlet ungerade states in N_2. Tunable narrowband XUV radiation was produced by successively pulsed amplification of cw dye laser radiation, frequency doubling the pulsed visible laser beam into the UV and frequency tripling the ...

2004-07-19

120

Crystal structure of ABPO{sub 5} and optical study of Pr{sup 3+} embedded in these compounds  

Energy Technology Data Exchange (ETDEWEB)

The crystal structure of borophosphates ABPO{sub 5} (A = alkaline earth or Pb) was resolved on a polycrystalline sample using the Rietveld method. The x-ray diffraction patterns data show that ABPO{sub 5} crystallize in a centrosymmetric space group P3{sub 1}21 and their structure is related to the borogermanates REBGeO{sub 5} with a stillwellite-type structure. Pr{sup 3+} ion was used as a local structural probe to corroborate the structural resolution results. Absorption and fluorescence spectra of A{sub 1-x}Pr{sub x}BP{sub 1-x}Ge{sub x}O{sub 5} (A alkaline earth or Pb; x = 0.05) have been investigated at different temperatures. At 9 K the 3{sup H}{sub 4}{yields}{sup 3}P{sub 0} transition of trivalent praseodymium ion (4f{sup 2} configuration) is observed as a single line. This indicates a unique crystallographic site for the rare earth ion in these compounds replacing the divalent cation. Energy level schemes were deduced from the low-temperature spectroscopic ...

2001-10-22

121

Crystal structure of ABPO_5 and optical study of Pr"3"+ embedded in these compounds  

International Nuclear Information System (INIS)

The crystal structure of borophosphates ABPO_5 (A = alkaline earth or Pb) was resolved on a polycrystalline sample using the Rietveld method. The x-ray diffraction patterns data show that ABPO_5 crystallize in a centrosymmetric space group P3_121 and their structure is related to the borogermanates REBGeO_5 with a stillwellite-type structure. Pr"3"+ ion was used as a local structural probe to corroborate the structural resolution results. Absorption and fluorescence spectra of A_1_-_xPr_xBP_1_-_xGe_xO_5 (A alkaline earth or Pb; x = 0.05) have been investigated at different temperatures. At 9 K the 3"H_4#->#"3P_0 transition of trivalent praseodymium ion (4f"2 configuration) is observed as a single line. This indicates a unique crystallographic site for the rare earth ion in these compounds replacing the divalent cation. Energy level schemes were deduced from the low-temperature spectroscopic measurements. Comparing the electronic level splittings of studied ...

2001-10-22

122

A systematic neutron reflectometry study on hydrogen absorption in thin Mg{sub 1-x}Al{sub x} alloy films  

Energy Technology Data Exchange (ETDEWEB)

Various methods for storing hydrogen have been examined in an effort to find ways to store hydrogen in increasingly smaller volumes with decreasing weight of the whole hydrogen storage system. Metal hydrides, in which hydrogen is chemically bound to a metal atom, are considered to be very promising candidates for hydrogen storage because they have high gravimetric and volumetric storage capacities. This study investigated the effect of different magnesium (Mg) and aluminium (Al) ratios on the absorption and desorption properties of thin films. Neutron reflectometry (NR) was used in this study to better understand the absorption and desorption properties of commercially promising hydrogen storage materials. The large negative scattering length of hydrogen atoms changes the reflectivity curve substantially, so that NR can determine the total amount of stored hydrogen as well as the hydrogen distribution along the film normal, with nanometer resolution. In order to ...

2010-10-15

123

Electronic absorption and emission spectra of Alq3 in solution with special attention to a delayed fluorescence  

International Nuclear Information System (INIS)

Tris(8-quinolinolato)aluminum(III) (Alq3) shows electronic absorption bands at 378, 360 (in a 1:1 mixed solvent of methanol and ethanol (ME) at 77 K), 334, 316, 300, 263, 255.8, and 233 nm in ethanol at room temperature. According to the polarized fluorescence excitation spectrum together with MO calculations, for instance, the 360 nm band is assigned to an LL CT transition (an intramolecular charge transfer transition between two ligands), and the 378 nm band to an LM/ML CT one (an intramolecular charge transfer transition between ligand and metal). Alq3 shows a broad fluorescence band peaking at around 478 nm in the ME matrix at 77 K. The emission spectrum measured with a phosphoroscope has two emission bands at 567 and 478 nm. The 567 nm band accompanies vibronic bands at 578 and 605 nm, being safely assigned to a phosphorescence of Alq3. ...

2008-08-01

124

Pressure and temperature tuning of InGaP/AlGaInP laser diodes from red to yellow  

Energy Technology Data Exchange (ETDEWEB)

Red laser diodes emitting at 636 nm and 645 nm are studied as a function of pressure up to 20 kbar and temperature from 300 K down to 80 K. The 636 nm samples reveal anomalous L-I-V dependence at low temperatures and at high pressures. The 645 nm samples do not show these anomalies and can be tuned by pressure and temperature down to 575 nm, i.e., in the 70 nm range with powers above 200 mW and low threshold currents. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2009-03-15

125

Challenges and Solutions to Producing a Useful High Resolution Soil Moisture Product  

Science.gov (United States)

Information about surface soil moisture conditions is of critical importance to real-world applications such as agricultural production, water resource management, flood prediction, fire prediction, water supply, military mobility, etc.. Near-surface soil moisture is currently available from non-ideal sensor configuration observations, and two missions targeted at measuring near-surface soil moisture with ideal sensor configuration are expected before the end of the decade (the European Space Agency (ESA), Soil Moisture and Ocean Salinity (SMOS) mission, and the National Aeronautics and Space Administration (NASA), Hydrospheric states "Hydros" mission). Though remote sensing can make spatially comprehensive measurements of surface soil moisture, it cannot provide information on the entire land surface hydrologic system, and the measurements represent only a snap shot in time. Alternatively, land surface hydrology process models may be used to predict the temporal ...

2005-05-01

132

Absorption of 308-nm excimer laser radiation by balanced salt solution, sodium hyaluronate, and human cadaver eyes  

Energy Technology Data Exchange (ETDEWEB)

Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 ...

1990-11-01

133

Triple ion-beam studies of radiation damage effects in a 316LN austenitic alloy for a high power spallation neutron source  

Energy Technology Data Exchange (ETDEWEB)

Austenitic 316LN alloy was ion-irradiated using the unique Triple Ion Beam Facility (TIF) at ORNL to investigate radiation damage effects relevant to spallation neutron sources. The TIF was used to simulate significant features of GeV proton irradiation effects in spallation neutron source target materials by producing displacement damage while simultaneously injecting helium and hydrogen at appropriately high gas/dpa ratios. Irradiations were carried out at 80, 200, and 350 C using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} to accumulate 50 dpa by Fe, 10,000 appm of He, and 50,000 appm of H. Irradiations were also carried out at 200 C in single and dual ion beam modes. The specific ion energies were chosen to maximize the damage and the gas accumulation at a depth of {approximately} 1 {micro}m. Variations in microstructure and hardness of irradiated specimens were studied using transmission electron microscopy (TEM) and a nanoindentation ...

1997-09-01

134

The phenomenon of microscale flow and mass transfer in medicinal herb materials  

Energy Technology Data Exchange (ETDEWEB)

Microwave assisted extraction (MAE) is a combination of a microwave technique and conventional solvent extraction used in the modernization of traditional Chinese medicine. The effective component of medicinal herbs is mostly cellular material which can be released via solvent extraction. The material is diffused to solvents via the porous membrane wall. The structure of herb morphology and characteristics of the solute's molecular weight play an important role in the extraction process of target compounds. Astragalus pieces were chosen for this study in which an ultra-filtration membrane method was used to determine the molecular weight distribution characteristics of Astragalus water extraction liquid in the process of MAE. The fine structure of matrix materials was also characterized by scanning election microscopy (SEM). The phenomenon of mass flow and mass transfer in the plant porous media was discussed along with the enhancement mechanism of ...

2008-07-01

135

Size and morphology of fine particle emissions from heavy-duty vehicles; Raskaan ajoneuvokannan hiukkaspaeaestoen koko ja morfologia - HD-PM  

Energy Technology Data Exchange (ETDEWEB)

Exhaust fine and ultra fine particle numbers, particle sizes, mass, shape, structure and density were studied from Euro II - EEV emission level heavy-duty vehicles. For total particle emission factors city buses were run on dynamic conditions simulating city bus driving. The new heavy-duty chassis dynamometer of VTT was used. Vehicles were a comprehensive sample of current city bus fleet, the type approved emission level of which was Euro II - Euro III. Also cleaner engines of Euro IV to EEV targeted emission level were included: CRT, CNG, DPF. Particle emissions of these buses were extremely low; numbers 1/100 - 1/1000 and masses 1/10 - 1/100 of those of the predominating techniques. Morphological properties of fine particle populations that represent majority of particle size distribution (Da < 500 nm) are being analyzed by image processing (Matlab) from electron microscopical images (SEM, ESEM and TEM) as a function of particle size. ...

2004-07-01

136

Scale-dependent errors in the estimation of land-cover proportions. Implications for global land-cover datasets  

Energy Technology Data Exchange (ETDEWEB)

Aggregation of fine-resolution land-cover maps to coarser scales indicates that estimates of the proportions of land-cover types vary as a function of spatial resolution. The magnitude of these proportional errors in a forested area in northern California increase significantly as resolution exceeds a 90-m threshold. These errors could pose difficulties for the use of land-cover products generated from coarse-resolution sensors such as the NOAA-AVHRR and the MODIS sensor planned for the EOS program. The magnitude of the errors appears to be a function of the spatial resolution of the map, the original size of the land-cover classes, and the spatial patterns of the classes.

1994-05-01

137

Purification of functional baculovirus particles from silkworm larval hemolymph and their use as nanoparticles for the detection of human prorenin receptor (PRR) binding  

UK PubMed Central (United Kingdom)

BackgroundBaculovirus, which has a width of 40 nm and a length of 250-300 nm, can display functional peptides, receptors and antigens on its surface by their fusion with a baculovirus...Full Text Available

138

High Contrast Near-infrared Polarized Reflectance Images of Demineralization on Tooth Buccal and Occlusal Surfaces at ?=1310-nm  

UK PubMed Central (United Kingdom)

Background and Objectives:Sound enamel manifests peak transparency in the near-IR (NIR) at 1310-nm, therefore the near-IR is ideally suited for high contrast imaging...Full Text Available

2009-03-01

139

Determination of binary mixtures of analgesic and spasmolytic drugs in pure and dosage forms by derivative spectrophotometry.  

Science.gov (United States)

Binary mixtures of dipyrone and pitophenone hydrochloride are assayed by zero-crossing second- and third-derivative spectrophotometry and by ratio-spectra first- and second-derivative spectrophotometry. In the first method, calibration plots are linear at 266.5 and 302.5 nm (dipyrone, second derivative), and 257 and 286 nm (pitophenone second derivative) and 242 and 278.3 nm (dipyrone third derivative), and 228.5 and 300 nm (pitophenone, third-derivative). By the second method, lines of regression are linear at 235 and 262 nm (dipyrone, first derivative), and 229.5 and 288.5 nm (pitophenone, first-derivative), and 249.7 and 268 nm (dipyrone, second derivative), and 280.5 and 300 nm (pitophenone, second-derivative). In all methods calibration curves follow the Beer's law up to 40 microg/ml of each drug. LOD and LOQ values ...

2003-10-15

140

Lasing below 200 nm in the NIJI-IV compact storage-ring-based free electron laser  

International Nuclear Information System (INIS)

Laser gain of the NIJI-IV compact storage-ring-based Free Electron Laser (FEL) system at AIST reached #approx#9% at 200 nm for an average beam current of 16.3 mA. In addition to such a drastic gain enhancement, improvement of the laser-cavity performance has led to successful FEL lasing in the vacuum ultraviolet below 200 nm even in a compact system. Temporal and spectral characteristics of the NIJI-IV FEL were examined around 200 nm. FEL performance will be briefly discussed from the application point of view.

2004-08-01

141

Fabrication of 10nm diameter carbon nanopores  

Energy Technology Data Exchange (ETDEWEB)

The addition of carbon to samples, during imaging, presents a barrier to accurate TEM analysis, the controlled deposition of hydrocarbons by a focused electron beam can be a useful technique for local nanometer-scale sculpting of material. Here we use hydrocarbon deposition to form nanopores from larger focused ion beam (FIB) holes in silicon nitride membranes. Using this method, we close 100-200nm diameter holes to diameters of 10nm and below, with deposition rates of 0.6nm per minute. I-V characteristics of electrolytic flow through these nanopores agree quantitatively with a one dimensional model at all examined salt concentrations.

2008-09-25

143

Targeting Prostate Cancer Cells In Vivo Using a Rapidly Internalizing Novel Human Single-Chain Antibody Fragment  

UK PubMed Central (United Kingdom)

Human antibodies targeting prostate cancer cell surface epitopes may be useful for imaging and therapy. The objective of this study was to evaluate the tumor targeting of an internalizing human...Full Text Available

2010-03-01

145

Isoform-level microRNA-155 target prediction using RNA-seq  

UK PubMed Central (United Kingdom)

Computational prediction of microRNA targets remains a challenging problem. The existing rule-based, data-driven and expression profiling approaches to target prediction are mostly approached from the...Full Text Available

2011-05-01

146

Delineating Bacteriostatic and Bactericidal Targets in Mycobacteria Using IPTG Inducible Antisense Expression  

UK PubMed Central (United Kingdom)

In order to identify novel high value antibacterial targets it is desirable to delineate whether the inactivation of the target enzyme will lead to bacterial death or stasis. This knowledge is particularly...Full Text Available

147

A thermal hydraulic investigation on ADSR liquid lead target  

Energy Technology Data Exchange (ETDEWEB)

Computational fluid dynamics(CFD) code FLUENT was used to simulate the thermal hydraulic processes occurring in conceptual design of the accelerator-driven subcritical reactor(ADSR) liquid lead target. The purpose of the analysis is to investigate the thermal hydraulic characteristics of liquid lead as ADSR target material with various target geometries and injection locations of proton beam. In the calculation analysis, the local temperature of the liquid lead target rises to the boiling temperature very rapidly. When the proton beam is injected from the bottom of the target system, the duration time to reach the boiling temperature is longer and the temperature distribution is flatter than other cases.

1998-05-01

148

Structures of trihydroxynaphthalene reductase-fungicide complexes: implications for structure-based design and catalysis  

Energy Technology Data Exchange (ETDEWEB)

Trihydroxynaphthalene reductase catalyzes two intermediate steps in the fungal melanin biosynthetic pathway. The enzyme, a typical short-chain dehydrogenase, is the biochemical target of three commercial fungicides. The fungicides bind preferentially to the NADPH form of the enzyme. Three X-ray structures of the Magnaporthe grisea enzyme complexed with NADPH and two commercial and one experimental fungicide were determined at 1.7 {angstrom} (pyroquilon), 2.0 {angstrom} (2,3-dihydro-4-nitro-1H-inden-1-one, 1), and 2.1 {angstrom} (phthalide) resolutions. The chemically distinct inhibitors occupy similar space within the enzyme's active site. The three inhibitors share hydrogen bonds with the side chain hydroxyls of Ser-164 and Tyr-178 via a carbonyl oxygen (pyroquilon and 1) or via a carbonyl oxygen and a ring oxygen (phthalide). Active site residues occupy similar positions among the three structures. A buried water molecule that is ...

2010-03-08

149

Recognition of subaerial exposure and flooding surfaces in carbonate-siliciclastic eolianites and marine carbonate sequences in southwester Kansas  

Energy Technology Data Exchange (ETDEWEB)

Recent work on the St. Louis Limestone in southwestern Kansas has demonstrated that these units contain a significant eolian facies component (up to 80-90% of total unit thickness). Reservoir intervals within the St. Louis are confined to relatively thin subtidal grainstones that, in turn, are capped by a muddy carbonate and shale facies. Critical to exploration and development of these grain-shoal reservoirs is an understanding of their spatial and stratigraphic distribution. Core through the St. Louis and St. Genevieve limestones has been examined and features have been recognized at the top of the eolianites. These surfaces are interpreted as long-term exposure surfaces. The contact between the subtidal grainstone shoals and the overlying muddy carbonate and shale facies is relatively sharp and is interpreted as representing a flooding surface separating shoal from muddy-open shelf facies. In the St. Louis Limestone, the subtidal carbonate grainstone reservoir intervals consist of ...

1993-09-01

150

Real-time neutron radiography at Texas A and M University  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...

1990-12-20

151

Real-time neutron radiography at Texas A and M University  

International Nuclear Information System (INIS)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...

1990-12-01

152

Preliminary study of metabolic radiotherapy with {sup 188}Re via small animal imaging  

Energy Technology Data Exchange (ETDEWEB)

{sup 188}Re is a {beta}{sup -} (Emax=2.12 MeV) and {gamma} (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, {sup 99m}Tc, molecules of hyaluronic acid (HA) have been labelled with {sup 188}Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm{sup 3} pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of {sup 188}Re and with C57 black mice injected with the {sup 188}Re-HA solution are presented. To increase the space resolution and to ...

2006-01-15

153

Plasma dynamics in PF-1000 device under full-scale energy storage: I. Pinch dynamics, shock-wave diffraction, and inertial electrode  

International Nuclear Information System (INIS)

This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ideal magnetohydrodynamic growth time ...

2007-04-07

154

Multi-Resolution Modeling of Large Scale Scientific Simulation Data  

Energy Technology Data Exchange (ETDEWEB)

Data produced by large scale scientific simulations, experiments, and observations can easily reach tera-bytes in size. The ability to examine data-sets of this magnitude, even in moderate detail, is problematic at best. Generally this scientific data consists of multivariate field quantities with complex inter-variable correlations and spatial-temporal structure. To provide scientists and engineers with the ability to explore and analyze such data sets we are using a twofold approach. First, we model the data with the objective of creating a compressed yet manageable representation. Second, with that compressed representation, we provide the user with the ability to query the resulting approximation to obtain approximate yet sufficient answers; a process called adhoc querying. This paper is concerned with a wavelet modeling technique that seeks to capture the important physical characteristics of the target scientific data. Our approach is driven by the ...

2002-02-25

155

Measuring q sub 0 using supernovae at z approx 0. 3  

Energy Technology Data Exchange (ETDEWEB)

The measurement of q{sub o} is extremely important for understanding the quantity of matter in our universe. The measurement of q{sub o} using supernovae of type Ia as standard candles is appealing because it requires less modeling than other methods using galaxies. The challenge with using supernovae to measure q{sub o} is in finding enough of them. In order to find supernovas, we have constructed a very popular f/1 camera for the 3.9m Anglo-Australian Telescope. The camera uses reducing optics that put a 17 in. {times} 17 in. field on a 1024 {times} 1024 pixel Thomson CCD. Using this system, we image to 23rd magnitude in five minutes. We have developed a software package that uses image subtraction to find supernovae that are approximately magnitude 22.4 or brighter in these images. One field can be processed every 6.6 minutes on a relatively unloaded VAX 6000-6510. We estimate that this system should find one supernova in every 105--139 images (about two nights of observation on the ...

1992-07-01

156

Mass spectrometric characterization of elements and molecules in cell cultures and tissues  

Energy Technology Data Exchange (ETDEWEB)

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) and laser post-ionization secondary neutral mass spectrometry (laser-SNMS) have been used to image and quantify targeted compounds, intrinsic elements and molecules with subcellular resolution in single cells of both cell cultures and tissues. Special preparation procedures for analyzing cell cultures and tissue materials were developed. Cancer cells type MeWo, incubated with boronated compounds, were sandwiched between two substrates, cryofixed, freeze-fractured and freeze-dried. Also, after injection with boronated compounds, different types of mouse tissues were extracted, prepared on a special specimen carrier and plunged with high velocity into LN{sub 2}-cooled propane for cryofixation. After trimming, these tissue blocks were freeze-dried. The measurements of the K/Na ratio demonstrated that for both cell cultures and tissue materials the special preparation techniques used were ...

2006-07-30

157

Experimental verification of convolution/superposition photon dose calculations for radiotherapy treatment planning  

International Nuclear Information System (INIS)

This work describes an experimental verification of the two-photon dose calculation engines available on the Helax-TMS (version 6.1) commercial radiotherapy treatment planning system. The performance of the pencil beam convolution and the collapsed cone superposition algorithms was examined for 4, 6, 15 MV beams, under a range of clinically relevant irradiation geometries. Comparisons against measurements were carried out in terms of absolute dose, thus assessment of the accuracy of monitor unit (MU) calculations was also carried out. Results show that both algorithms agree with measurement to acceptable tolerance levels in most cases in homogeneous water-equivalent media irradiated under full scatter conditions. The collapsed cone algorithm slightly overestimates the penumbra width and this is mainly due to discretization effects of the fluence matrix. The accuracy of this algorithm strongly depends on the resolution of the patient density matrix. It is ...

2003-09-07

158

Activation cross sections of deuteron-induced nuclear reactions on hafnium  

International Nuclear Information System (INIS)

Experimental excitation functions for deuteron-induced reactions up to 20 MeV on high purity natural hafnium were measured with the activation method using a stacked foil irradiation technique. Metallic hafnium foils with thickness of 10 #mu#m were stacked together with 50 #mu#m thick aluminium and 12 #mu#m thick titanium foils. The aluminium foils served as energy absorber while the titanium foils were used to monitor the energy and intensity of the bombarding deuteron beam. From a detailed remeasurement of the complete excitation function of the "n"a"tTi(d,x)"4"8V monitor reaction it was possible to adopt the proper incident energy and beam intensity by comparing the results with the recommended values. High resolution off-line gamma-ray spectrometry was applied to assess the activity of each foil. From the measured activity independent and/or cumulative elemental or isotopic cross section data for production of Ta, Hf and Lu radioisotopes by (d,x) reactions were ...

2010-11-15

159

ARM AND INTERARM STAR FORMATION IN SPIRAL GALAXIES  

International Nuclear Information System (INIS)

We investigate the relationship between spiral arms and star formation in the grand-design spirals NGC 5194 and NGC 628 and in the flocculent spiral NGC 6946. Filtered maps of near-IR (3.6 #mu#m) emission allow us to identify 'arm regions' that should correspond to regions of stellar mass density enhancements. The two grand-design spirals show a clear two-armed structure, while NGC 6946 is more complex. We examine these arm and interarm regions, looking at maps that trace recent star formation-far-ultraviolet (GALEX NGS) and 24 #mu#m emission (Spitzer SINGS)-and cold gas-CO (HERACLES) and H I (THINGS). We find the star formation tracers and CO more concentrated in the spiral arms than the stellar 3.6 #mu#m flux. If we define the spiral arms as the 25% highest pixels in the filtered 3.6 #mu#m images, we find that the majority (60%) of star formation tracers occur in the interarm regions; this result persists qualitatively even when considering the potential impact of finite data ...

2010-12-10

160

A unified framework for capturing facial images in video surveillance systems using cooperative camera system  

Science.gov (United States)

Low resolution and un-sharp facial images are always captured from surveillance videos because of long human-camera distance and human movements. Previous works addressed this problem by using an active camera to capture close-up facial images without considering human movements and mechanical delays of the active camera. In this paper, we proposed a unified framework to capture facial images in video surveillance systems by using one static and active camera in a cooperative manner. Human faces are first located by a skin-color based real-time face detection algorithm. A stereo camera model is also employed to approximate human face location and his/her velocity with respect to the active camera. Given the mechanical delays of the active camera, the position of a target face with a given delay can be estimated using a Human-Camera Synchronization Model. By controlling the active camera with corresponding amount of pan, tilt, and zoom, a clear ...

2008-04-01

161

Improvement of spatial resolution in the longitudinal direction for isotropic imaging in helical CT  

Energy Technology Data Exchange (ETDEWEB)

Experiments were conducted to confirm the isotropic spatial resolution of multislice CT with a 0.5 mm slice thickness. Isotropic spatial resolution means that the spatial resolution in the transaxial plane (X-Y plane) and that in the longitudinal direction (Z direction) are equivalent. To obtain point spread function (PSF) values in the X-Y-Z directions, three-dimensional voxel data were obtained by helical scanning of a bead phantom. The modulation transfer function (MTF) values were then obtained by three-dimensional Fourier transform of the PSF. Evaluation of the spatial resolution in the X-Y-Z directions by the MTF values showed that the spatial resolution in the Z direction does not depend on the reconstruction kernel used. It was also found that the spatial resolution in the Z direction, as compared with that in the X-Y plane, is superior with the standard ...

2007-02-07

162

The response of small scale rigid targets to shallow buried explosive detonations  

British Library Electronic Table of Contents (United Kingdom)

Experimental and computational investigations were performed in order to better understand the mechanical response of rigid targets with various geometries to the detonation of shallow buried explosives. The motion of the targets was measured by use of high-speed digital video photography. This work involved flat targets, targets that were downwardly convex, and targets that were downwardly concave with explosive charges located at various positions beneath the targets. It was observed that, in general, angled hulls - whether downwardly concave or convex - tended to reduce the amount of momentum imparted to the center of mass of the targets. Computations were performed by use of an arbitrary Langrangian-Eulerian treatment in a nonlinear finite element code. A model based on quasi-static te...

2011-01-01

163

Targeting a Ruthenium Complex to the Nucleus with Short Peptides  

UK PubMed Central (United Kingdom)

In an effort to develop octahedral metal complexes as chemotherapeutic and diagnostic agents targeted to DNA, it is critical to optimize the properties of their cellular uptake. Appending d-octaarginine...Full Text Available

2010-05-15

164

Target stations and beam dumps for the CERN SPS  

International Nuclear Information System (INIS)

The design of the absorber blocks for internal and external dumping of the SPS proton beam is discussed. In addition, the external target stations for slow and fast extracted proton beams are described.

1977-03-16

165

Suitability of a New Plant Invader as a Target for Biological Control in Florida  

Science.gov (United States)

... L. Sutton. 2000. Is the aquatic weed hygrophila, Hygrophila polysperma (Polemoniales: Acanthaceae), a suitable target for classical biological ... ...

166

Nato SCI-12 on Camouflage Evaluation Workshop on Search and Target ...  

Science.gov (United States)

Nato SCI-12 on Camouflage Evaluation Workshop on Search and Target Acquisition The Netherlands, June 1999. Image Discrimination Models for Object Detection ...

167

FOR THIN AND THICK TARGETS - NASA Technical Report Server (NTRS)  

Science.gov (United States)

By W. Wayne Scott. Langley Research Center. SUMMARY. Thin- and thick-target bremsstrahlung spectra are presented for electron energies up to 7.0 MeV. ...

168

Ag/C nanoparticles as an cathode catalyst for a zinc-air battery with a flowing alkaline electrolyte  

Energy Technology Data Exchange (ETDEWEB)

The cyclic voltammetry indicated that the oxygen reduction reaction (ORR) proceeded by the four-electron pathway mechanism on larger Ag particles (174 nm), and that the ORR proceeded by the four-electron pathway and the two-electron pathway mechanisms on finer Ag particles (4.1 nm), simultaneously. The kinetics towards ORR was measured at a rotating disk electrode (RDE) with Ag/C electrode. The number of exchanged electrons for the ORR was found to be close to four on larger Ag particles (174 nm) and close to three on finer Ag particles (4.1 nm). The zinc-air battery with Ag/C catalysts (25.9 nm) was fabricated and examined. (author)

2009-09-05

169

Field driven ferromagnetic phase evolution originating from the domain boundaries in antiferromagnetically coupled perpendicular anitsotropy films  

Energy Technology Data Exchange (ETDEWEB)

Strong perpendicular anisotropy systems consisting of Co/Pt multilayer stacks that are antiferromagnetically coupled via thin Ru or NiO layers have been used as model systems to study the competition between local interlayer exchange and long-range dipolar interactions [1,2]. Magnetic Force Microscopy (MFM) studies of such systems reveal complex magnetic configurations with a mix of antiferromagnetic (AF) and ferromagnetic (FM) phases. However, MFM allows detecting surface stray fields only and can interact strongly with the magnetic structure of the sample, thus altering the original domain configuration of interest [3,4]. In the current study they combine magnetometry and state-of-the-art soft X-ray transmission microscopy (MXTM) to investigate the external field driven FM phase evolution originating from the domain boundaries in such antiferromagnetically coupled perpendicular anisotropy films. MXTM allows directly imaging the perpendicular component of the magnetization in an ...

2008-05-01

170

Characterisation of thin films on rough steel substrates by FTIR microscopy and imaging  

International Nuclear Information System (INIS)

Complete text of publication follows. According to the new European regulations (Restrictions of Hazardous Substance Directive), there is an emerging demand for environmental friendly metal treatments instead on formerly used chromate conversion coating technique. The aim of the present investigations was to characterise and compare silicon containing protective thin layers on roughened galvanized steel surfaces (with average roughness of 0.7 microns), using FTIR microscopy and imaging techniques. The silicon containing coatings were produced either by Chemical Vapour Deposition (CVD) or by wet chemical treatment using liquid silane. FTIR techniques offer new possibilities in the characterisations and chemical mapping of differently coated thin films, besides SEM+EDS, AFM, nanoindentation, XPS measurements (P. Nemeth et al., Materials Science Forum, 589 (2008) 433-438). All measurements were carried out by a Varian FTS-7000 spectrometer with a 'Stingray' microscope configuration ...

171

Hydrogen-related surface modifications of 20 nm thin straight-sided niobium nano-wires and niobium meander-films  

Energy Technology Data Exchange (ETDEWEB)

Nano-wire arrays of Niobium were produced by small angle sputtering on facetted sapphire, using the self shadowing effect of the facets. A wire width of about 80 nm was adjusted, the mean (maximum) wire height was about 20 nm (30 nm), the length can be in the cm range. Meander-film morphologies of 20 nm mean (26 nm maximum) thickness were produced by conventional sputtering onto smooth sapphire substrates at elevated temperatures. The morphology of the wires was investigated with atomic force microscopy (AFM), using contact mode. Meander-films were studied by scanning tunnelling microscopy (STM). Hydrogen loading was performed by instantaneously increasing the hydrogen gas pressure above the solubility limit. Thus, an elongated hydride could be monitored in an about 30 nm thick wire. STM studies on meander-films show the presence of cylindrical hydrides. Local ...

2007-10-31

172

Electronic spectra of plutonium ions in nitric acid and in lithium nitrate solutions  

International Nuclear Information System (INIS)

The absorption spectra of plutonium ions in nitric acid have been described. There is a characteristic change in the absorption spectra of Pu v in lithium nitrate solutions. In 2 M-lithium nitrate a new peak at 969 nm and high absorption at 1200 nm are noticed. A decrease in the absorption by about 20% and the appearance of a new shoulder at 1120 nm in 6 M-lithium nitrate are found. There is no change in the spectrum in 4 M-lithium nitrate. The absorption spectra of plutonium ions in the spectral range 200 - 400 nm are interesting. All plutonium ions have an intense band in the region 250 - 260 nm as well as a less intense and rather diffuse band at 320 - 330 nm in lithium nitrate solutions the sharp band at 250 - 260 nm has disappeared. This suggests that this band is very sensitive to the environmental field. The band is probably produced ...

1998-05-07

173

Comparative action spectrum for ultraviolet light killing of mouse melanocytes from different genetic coat color backgrounds  

International Nuclear Information System (INIS)

The photobiology of mouse melanocyte lines with different pigment genotypes was studied by measuring colony-forming ability after irradiation. The cell lines were wild-type black (melan-a) and the mutants brown (melan-b) and albino (melan-c). Four lamps emitting various UV wavelengths were used. These were germicidal (UVC, 200-280 nm), 82.3% output at 254 nm, TL01 (UVB, 280-320 nm), 64.2% at 310-311 nm, FS20, broadband with peak output at 312 nm and Alisun-S (UVA, 320-400 nm), broadband with peak output at 350-354 nm. Appropriate filtration reduced the contaminating UVC to nonlethal levels for the longer waverange lamps. It is clear from these studies that, in pigment cells, monochromatic results cannot predict polychromatic responses and that cell death from solar irradiations is a complex phenomenon that depends on more than DNA damage. ...

1997-01-01

174

Visual mental imagery during caloric vestibular stimulation  

UK PubMed Central (United Kingdom)

We investigated high-resolution mental imagery and mental rotation, while the participants received caloric vestibular stimulation. High-resolution visual mental imagery tasks have been shown...Full Text Available

2006-01-01

175

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system ...

2001-01-01

176

Nuclear magnetic resonance imaging of hepatic focal injuries with phased array antennae surface: apnoea or high resolution imagery?  

International Nuclear Information System (INIS)

French English ... Orig. Title Imagerie IRM des lesions focales hepatiques avec les antennes de surface en reseau phase (phased array): apnee ou imagerie haute resolution?.

1995-10-26

177

Multi-focal optical-resolution photoacoustic microscopy in vivo  

UK PubMed Central (United Kingdom)

Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available

2011-04-01

178

Investigation of the hadronic final state in electron-proton interactions at HERA  

Energy Technology Data Exchange (ETDEWEB)

The main subject of this thesis is the study of the hardronic final state in deep-inelastic electron-proton scattering. Theexperiment described in this thesis is performed with such a high resolution that the substructure of the proton is probed by the electron beam with a resolution of less than 10{sup -15} cm. (orig./HSI).

1995-09-18

179

High-resolution infrared observations in IC 5146  

Energy Technology Data Exchange (ETDEWEB)

High-resolution near-infrared and far-infrared observations are presented of the southeastern molecular cloud fragment in the IC 5146 dark cloud. These observations rule out earlier suggestions for the formation of massive stars in this fragment.

1984-04-01

180

High-Speed Ultrahigh-Resolution Optical Coherence Tomography Findings in Chronic Solar Retinopathy  

UK PubMed Central (United Kingdom)

PurposeTo describe ocular findings for a 34-year-old man with chronic solar retinopathy using high-speed ultrahigh-resolution (UHR) optical coherence tomography (OCT).Full Text Available

2008-01-01

181

High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe  

UK PubMed Central (United Kingdom)

Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available

2010-03-01

182

Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs  

UK PubMed Central (United Kingdom)

We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available

2010-01-01

183

Changes in Gingival Crevicular Fluid Inflammatory Mediator Levels during the Induction and Resolution of Experimental Gingivitis in Humans  

UK PubMed Central (United Kingdom)

AimThe goal of this study is to characterize the changes in 33 biomarkers within the gingival crevicular fluid during the 3-week induction and 4-week resolution of...Full Text Available

2010-04-01

184

An automated procedure for detecting protein folds from sub-nanometer resolution electron density  

UK PubMed Central (United Kingdom)

The use of sub-nanometer resolution electron density as spatial constraints for denovo and ab-initio structure prediction requires knowledge of protein boundaries...Full Text Available

2010-06-01

185

A non-local approach for image super-resolution using intermodality priors ?  

UK PubMed Central (United Kingdom)

Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available

2010-08-01

186

Target R and D at JAERI  

Energy Technology Data Exchange (ETDEWEB)

We proposed a solid and a mercury target concepts through the preliminary conceptual design. To feasible these concepts, analysis and experimental works are being carried out. This paper introduces an outline of present status of target R and D such as heat transfer augmentation experiments for the solid target, mercury flow tests with a loop of maximum flow rate of 15L/min, flow pattern measurements for a cold source moderator etc. as well as preliminary conceptual design works. (author)

1999-03-01

191

SAMS Research and Development  

Science.gov (United States)

... resolution video. RESULTS Statistics describing the typical inertial navigation error growth were collected. Typical errors ...

2008-08-06

193

Nuclear structure physics at high resolution  

Energy Technology Data Exchange (ETDEWEB)

Techniques for studying nuclear structure are reviewed. Examples are given of charge density determinations by electron and proton inelastic scattering. (AIP)

1985-04-01

194

High Resolution Mesoscale Weather Data Improvement to ...  

Science.gov (United States)

... that defines hydrometeor categories for the duration of the simulation ... and to observe the movement of any particular system ... particle settling occurred ...

2007-03-01

195
196

Detection and Diagnosis of Oral Neoplasia with an Optical ...  

Science.gov (United States)

... Thus, 0CM provides the potential to image epithelial tissue with the subcellular resolution needed to assess the pathologic state of tissue. ...

197

C-CAP Land Cover, Maui, Hawaii 2006  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

198

Alignment accuracy of focused ion beam implantation  

Energy Technology Data Exchange (ETDEWEB)

The theoretical alignment limit for focused ion beam (FIB) implantation was deduced from the calculated resolution for the detection of an alignment mark. The alignment resolution varies with the signal to noise ratio and there is an optimum current which gives the best resolution. The alignment resolution epsilon/sub sigma/ is approximately 0.006 ..mu..m for a 160 keV Si/sup ++/ beam from our FIB implanter. The measured alignment error is approximately 0.06 ..mu..m and the main reason of this discrepancy is vibration. The ultimate limit on the alignment error can be reached through improvements in the implanter system.

1987-06-01

200

A He-gas Cooled, Stationary Granular Target  

CERN Document Server

In the CERN approach to the design of a neutrino factory, the repetition frequency of the proton beam is high enough to consider stationary solid targets as a viable solution for multi-MW beams. The target consists of high density tantalum spheres of 2 mm diameter which can efficiently be cooled by passing a high mass flow He-gas stream through the voids between the Ta-granules. Very small thermal shocks and stresses will arise in this fine grained structure due to the relatively long burst of 3.3 ms from the SPL-proton linac. In a quadruple target system where each target receives only one quarter of the total beam power of 4 MW, conservative temperature levels and adequate lifetimes of the target are estimated in its very high radiation environment. A conceptual design of the integration of the target into the magnetic horn-pion-collector is presented.

2003-01-01

201

Coulomb Repulsion in Miniature Ion Mobility Spectrometry  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a study of ion mobility resolution in a miniature ion mobility spectrometer with a drift channel 1.7 mm in diameter and 35 mm in length. The device attained a maximum resolution of 14 in separating ions of NO, O{sub 2}, and methyl iodine. The ions were generated by pulses from a frequency-quadrupled Nd:YAG laser. Broadening due to Coulomb repulsion was modeled theoretically and shown experimentally to have a major effect on the resolution of the miniature device.

1999-08-08

202

High resolution sequence stratigraphy in China  

International Nuclear Information System (INIS)

Since high resolution sequence stratigraphy was introduced into China by DENG Hong-wen in 1995, it has been experienced two development stages in China which are the beginning stage of theory research and development of theory research and application, and the stage of theoretical maturity and widely application that is going into. It is proved by practices that high resolution sequence stratigraphy plays more and more important roles in the exploration and development of oil and gas in Chinese continental oil-bearing basin and the research field spreads to the exploration of coal mine, uranium mine and other strata deposits. However, the theory of high resolution sequence stratigraphy still has some shortages, it should be improved in many aspects. The authors point out that high resolution sequence stratigraphy should be characterized quantitatively and modelized by computer techniques. (authors)

2008-11-01

203

Study of total ionizing dose radiation effects on nitride/oxide stack gate MOS capacitor  

International Nuclear Information System (INIS)

The aim of this paper is to investigate the total ionizing dose (TID) radiation effects on MOS capacitor with nitride/oxide stack gate. The stack gate MOS capacitors are fabricated with 20 nm oxide, 40 nm nitride or 110 nm nitride respectively. Through the analysis of CV curve of the irradiation capacitors, it is found that the degradation of the CV curve is due to a significant increase of interface traps and somewhat smaller oxide charge. It is also shown that the thicker of the nitride, more interface traps and oxide charge will be occurred. (authors)

2008-07-01

204

Transmission electron microscopy characterisation of permalloy elements fabricated by focussed ion beam lithography  

International Nuclear Information System (INIS)

20 nm thick permalloy elements, with dimensions of 500 x 500 nm"2 and 1000 x 200 nm"2, have been fabricated on 50 nm thick silicon nitride substrate by milling using a focussed ion beam (FIB) microscope. The dose of ion beam used for the milling was varied in order to achieve the best definition for the milled areas. The FIB milled elements were characterised physically by atomic force microscopy (AFM) and bright field transmission electron microscopy (TEM) and magnetically by Fresnel imaging on a TEM modified for magnetic imaging. The FIB milled elements were found to have a more irregular edge and lower magnetic fields for events such as vortex annihilation when compared to elements of the same dimensions fabricated by conventional electron beam microscopy (EBL).

2006-02-22

205

Spectroscopy of a narrow-line laser cooling transition in atomic dysprosium  

CERN Document Server

The laser cooling and trapping of ultracold neutral dysprosium has been recently demonstrated using the broad, open 421-nm cycling transition. Narrow-line magneto-optical trapping of Dy on longer wavelength transitions would enable the preparation of ultracold Dy samples suitable for loading optical dipole traps and subsequent evaporative cooling. We have identified the closed 741-nm cycling transition as a candidate for the narrow-line cooling of Dy. We present experimental data on the isotope shifts, the hyperfine constants A and B, and the decay rate of the 741-nm transition. In addition, we report a measurement of the 421-nm transition's linewidth, which agrees with previous measurements. We summarize the laser cooling characteristics of these transitions as well as other narrow cycling transitions that may prove useful for cooling Dy.

2010-01-01

206

Spectral analysis of Pr3+-, Sm3+- and Dy3+-doped transparent GeO2-BaO-TiO2 glass ceramics  

British Library Electronic Table of Contents (United Kingdom)

In this paper, we present the photoluminescence properties of Pr3+-, Sm3+- and Dy3+-doped germanate glasses and glass ceramics. From the X-ray diffraction measurement, the host glass structure was determined. These glasses have shown strong absorption bands in the near-infrared (NIR) region. Compared to Pr3+-, Sm3+- and Dy3+-doped glasses, their respective glass ceramics have shown stronger emissions due to the Ba2TiGe2O8 crystalline phase. For Pr3+-doped glass and glass ceramic, emission bands centered at 530nm (3P03H5), 614nm (3P03H6), 647nm (3P03F2) and 686nm (3P03F3) have been observed with 485nm (3H43P0) excitation wavelength. Of them, 647nm (3P03F2) has shown bright red emission. Emission bands of 4G5/26H5/2 (565nm), 4G5/26H7/2 (602nm) and 4G5/26H9/2 (648nm) for the Sm3+:glass and gl...

2009-01-01

207

Solution state hybridization detection using time-resolved fluorescence anisotropy of quantum dot-DNA bioconjugates  

British Library Electronic Table of Contents (United Kingdom)

In this Letter, we demonstrate the application of time-resolved fluorescence anisotropy measurements to detect solution state hybridization of streptavidin conjugate (CdSe)ZnS quantum dots (QD). The study was performed on samples containing 10nM QD incubated with 800nM DNA. We show that the rotational correlation time of QD-DNA constructs increases significantly upon hybridization with values of 330ns (QD-ssDNA) and 1.3ms (QD-dsDNA), corresponding to a diameter of 14nm and 23nm respectively. The present study opens a new modality for hybridization detection using quantum dots.

2010-01-01

208

NASA Standard for Models ... - JPL Technical Reports Server - NASA  

Science.gov (United States)

Hemez9 on the Predictive Capability Maturity Model, and for their feedback on the CAS d uring a 2 007 technical interchange meeting in Albuquerque, NM. ...

209

Indoleacetic Acid and Abscisic Acid Antagonism  

UK PubMed Central (United Kingdom)

The effects of low concentrations (10 nm or less) of indoleacetic acid and abscisic acid on the phytochrome-mediated attachment of barley root (Hordeum vulgare L., var. Compana)...Full Text Available

1973-01-01

210

Excimer Projection Lithography at 193-nm Wavelength  

Science.gov (United States)

... Corporate Author : MASSACHUSETTS INST OF TECH LEXINGTON LINCOLN LAB. Personal Author(s) : Rothschild, M. ; Ehrlich, DJ. ...

211

County Business Patterns  

Science.gov (United States)

Lea, MN Micro Albertville, AL Micro Albuquerque, NM Metro Alexander City, AL Micro Alexandria, LA Metro Alexandria, MN Micro Alice, TX Micro Allegan, MI Micro...

2011-10-08

212

An application of UV-derivative spectrophotometry and bivariate calibration algorithm for study of photostability of levomepromazine hydrochloride  

British Library Electronic Table of Contents (United Kingdom)

Derivative spectrophotometry and bivariate calibration algorithm were used for study of run of photooxidation of levomepromazine hydrochloride (LV). The actual concentrations of LV and its main degradation product levomepromazine sulphoxide (LV-SO) were calculated using data provided by applied methods. The direct reading of absorbance values at 302nm and 334nm were employed for quantification of LV and LV-SO, respectively, in the case of bivariate method. The derivative spectrophotometric method is based on transformation of zero-order spectra into first derivative. The values of first derivative at 334nm were used for quantification of LV while at 278nm for assay of LV-SO. The obtained quantitative data were applied for investigation of kinetics of photodegradation of LV.

2008-01-01

214

[Hadroproduction of charmed and bottom mesons (Fermilab experiment E-653): Progress report, June 13, 1983--June 14, 1984  

Energy Technology Data Exchange (ETDEWEB)

(I)Results are given for photoproduction of the D{sup *} at 103 GeV. Clean signals are seen for the decay D{sup *{+-}} {yields} {pi}{sup {+-}}D{sup 0} with the D{sup 0} decaying into both K{sup {-+}}{pi}{sup {+-}} and K{sup {-+}}{pi}{sup {+-}}{pi}{sup 0}. Analysis of the Dalitz plot for the K{pi}{pi} mode gives branching fractions (BFs) for K{sup {minus}}{rho}{sup +}, K{sup *{minus}}{pi}{sup +}, and {anti K}{sup *0}{pi}{sup 0} final states. The BF for D{sup 0} {yields} K{sup {minus}}{rho}{sup +}, much lower than a previous result, is in approximate agreement with the value expected for an l=1/2 final state. (II)Inelastic and elastic J/{psi} photoproduction on H is investigated at 103 GeV. The inelastic cross section with E{sub {psi}}/E{sub {gamma}} {lt} 0.9 is significantly lower than the corresponding result for muoproduction on Fe targets, but consistent with second-order perturbative QCD calculation. The mean p{sub +} of inelastic events is larger than that of ...

1984-12-31

215

Boundary Migration in Rutile  

Energy Technology Data Exchange (ETDEWEB)

TiO{sub 2} is a vital material in several technologies including, photocatalysis, gas sensing, biomaterials and optical coatings. Among the several crystal structures of this oxide, rutile has the highest density and microhardness, the highest index of refraction and the highest temperature stability. The processing of dense polycrystalline materials often includes the addition of a liquid-forming phase at higher temperatures. This technique is known as liquid-phase sintering and has been studied extensively. Rutile boundaries containing an amorphous phase have been used to study boundary migration and grain-boundary grooving. Visible-light (VLM), scanning electron (SEM) and transmission electron microscopy (TEM) in addition to electron-backscatter diffraction (EBSD) and a focused-ion beam (FIB) tool were used to characterize boundary migration in rutile. EBSD analysis was carried out on a Philips XL30 FEG SEM equipped with a DigiView 1612 high-resolution, ...

2003-08-01

216

Visible semiconductor laser operation below 640 nm at room temperature  

International Nuclear Information System (INIS)

Recent progress with the (Al_xGa_1_-_x)_0_._5In_0_._5P alloy system has resulted in laser diodes which operate at room temperature at wavelengths below 640 nm. OMVPE is used to grow the multi-quantum-well devices in a graded-index separate-confinement configuration. Laser threshold currents as low as 75 mA have been achieved.

1988-11-02

217

Radiation hardening of optical fiber links by photobleaching with light of shorter wavelength  

International Nuclear Information System (INIS)

The influence of additionally injected short-wavelength photobleaching light on the radiation hardness of Ge-doped graded index fibers working at 1,300 nm wavelength is investigated. Predictions are complicated by the fact that more efficient shortwave bleaching light experiences higher radiation-induced loss. Promising results are found for low fiber temperatures (approx-lt -50 C) and bleaching light of about 835 nm wavelength.

1995-09-18

218

Organic light-emitting devices based on solution-processible quinolato-complex supramolecules  

International Nuclear Information System (INIS)

This paper discusses a new type of supramolecular material tris{5-N-[3-(9H-carbazol-9-yl)propyl]-N-(4-methylphenyl) aminesulfonyl-8-hydroxyquinolato} aluminum(III), Al(SCarq)3, which we synthesized using three 5-N-[3-(9H-carbazol-9-yl)propyl]-N-(4-methylphenyl) aminesulfonyl-8-hydroxyquinoline as bidentate ligands. The peak photoluminescence in the solid phase appears at 488 nm. In cyclic voltammetric measurement, two oxidation peaks, which were obtained at -5.6 and -5.9 eV, correspond to HOMO sites of carbazoyl and aluminum quinolates, respectively. In the investigation of solid morphological thin film, the flat surface was investigated using an atomic force microscope. The root mean square (rms) and mean roughness (Ra) were respectively measured to be 0.427 and 0.343 nm. For the fabrication of organic light-emitting devices (OLEDs) using spin-coating techniques, the turn-on voltage and maximum luminescence of the optimized electroluminescence ...

2009-02-15

219

Fabrication of Porous TiO2 Hollow Spheres and Their Application in Gas Sensing  

UK PubMed Central (United Kingdom)

In this work, porous TiO2 hollow spheres with an average diameter of 100 nm and shell thickness of 20 nm were synthesized by a facile hydrothermal method with NH4HCO3...Full Text Available

220

Coumarin-4 laser efficiency up to 0. 14% under coaxial flash-lamp pumping  

Energy Technology Data Exchange (ETDEWEB)

Under coaxial flash lamp pumping the laser efficiency of coumarin-4 in slightly basic ethyl alcohol solution as an active medium has reached a value of 0.14%. That is three times higher than that in the basic aqueous solution. Its tunable wavelength range of laser output has extended from 440 to 510 nm with the maximum at 460 nm.

1987-02-01

221

Variation in the Definition of Clinical Target Volumes for Pelvic Nodal Conformal Radiation Therapy for Prostate Cancer  

UK PubMed Central (United Kingdom)

PurposeWe conducted a comparative study of Clinical Target Volume (CTV) definition of pelvic lymph nodes by multiple GU radiation oncologists looking at the levels...Full Text Available

2009-06-01

222

Targeted nanoparticles that deliver a sustained, specific release of paclitaxel to irradiated tumors  

UK PubMed Central (United Kingdom)

To capitalize on the response of tumor cells to ionizing radiation, we developed a controlled-release nanoparticle drug delivery system using a targeting peptide that recognizes a radiation-induced...Full Text Available

2010-06-01

223

Targeted Deletion of Somatotroph Insulin-Like Growth Factor-I Signaling in a Cell-Specific Knockout Mouse Model  

UK PubMed Central (United Kingdom)

The role of IGF-I in the negative regulation of GH expression and release is demonstrated by in vitro and in vivo models; however, the targets and mechanisms of IGF-I...Full Text Available

2010-05-01

224

Specific genetic modifications of domestic animals by gene targeting and animal cloning  

UK PubMed Central (United Kingdom)

The technology of gene targeting through homologous recombination has been extremely useful for elucidating gene functions in mice. The application of this technology was thought impossible in the large...Full Text Available

225

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

226

National Newborn Screening Status Reports  

Science.gov (United States)

... detected (and reported) as a by-product of MRM screening (MS/MS) targeted by Law or Rule ... detected (and reported) as a by-product of MRM screening (MS/MS) targeted by Law or Rule ...

227

Inhibitors of RecA Activity Discovered by High-Throughput Screening: Cell-Permeable Small Molecules Attenuate the SOS Response in Escherichia coli  

UK PubMed Central (United Kingdom)

The phenomenon of antibiotic resistance has created a need for the development of novel antibiotic classes with non-classical cellular targets. Unfortunately, target-based drug discovery against...Full Text Available

2009-10-01

228

How DNA coiling enhances target localization by proteins  

UK PubMed Central (United Kingdom)

Many genetic processes depend on proteins interacting with specific sequences on DNA. Despite the large excess of nonspecific DNA in the cell, proteins can locate their targets rapidly. After initial...Full Text Available

2008-10-14

229

Evolutionary conservation of a microbody targeting signal that targets proteins to peroxisomes, glyoxysomes, and glycosomes  

UK PubMed Central (United Kingdom)

Peroxisomes, glyoxysomes, glycosomes, and hydrogenosomes have each been classified as microbodies, i.e., subcellular organelles with an electron-dense matrix that is bound by a single membrane. We investigated...Full Text Available

1991-09-01

230

Efficient use of accessibility in microRNA target prediction  

UK PubMed Central (United Kingdom)

Considering accessibility of the 3′UTR is believed to increase the precision of microRNA target predictions. We show that, contrary to common belief, ranking by the hybridization energy or by...Full Text Available

2011-01-01

231

Coordination of PAD4 and HDAC2 in the regulation of p53 target gene expression  

UK PubMed Central (United Kingdom)

Histone Arg methylation and Lys acetylation have been found to cooperatively regulate the expression of p53 target genes. Peptidylarginine deiminase 4 (PAD4) is an enzyme that citrullinates...Full Text Available

2010-05-27

232

Concurrent schedule control of human visual target fixations1  

UK PubMed Central (United Kingdom)

Operant conditioning techniques were applied to the study of how target fixations are controlled by the probability of signal occurrence. In a standard vigilance setting, gaze at three illuminable...Full Text Available

1973-11-01

233

Biphasic targeting and cleavage furrow ingression directed by the tail of a myosin II  

UK PubMed Central (United Kingdom)

Cytokinesis in animal and fungal cells utilizes a contractile actomyosin ring (AMR). However, how myosin II is targeted to the division site and promotes AMR assembly, and how the AMR coordinates with...Full Text Available

2010-12-27

234

Assessment of nodal target definition and dosimetry using three different techniques: implications for re-defining the optimal pelvic field in endometrial cancer  

UK PubMed Central (United Kingdom)

Purposes1. To determine the optimal pelvic nodal clinical target volume for post-operative treatment of endometrial cancer. 2. To compare the DVH of different treatment planning...Full Text Available

235

Time-dependent infrared emission following photodissociation of nitromethane and chloropicrin.  

Science.gov (United States)

Nitromethane (CH(3)NO(2)) and its chlorinated analogue, chloropicrin (CCl(3)NO(2)), were photolyzed at 193, 248, and 266 nm, and the products were observed by time-dependent Fourier transform infrared emission spectroscopy. At 193 and 248 nm, the primary photodissociation pathway for nitromethane was cleavage of the C-N bond to produce CH(3) + NO(2)(A (2)B(2)). At 266 nm, weak emission was observed following photodissociation of nitromethane, but an infrared spectrum could not be obtained. The photodissociation of chloropicrin at 193 nm produced the analogous product channel CCl(3) + NO(2)(A (2)B(2)) in addition to several other product channels. At 248 and 266 nm, only CCl(3) + NO(2)(A (2)B(2)) was observed. The production of phosgene (CCl(2)O) from chloropicrin photodissociation was not observed in this study. PMID:16571044

2006-04-01

236

Structure and magnetic properties of nanocrystalline Fe-Mo alloys prepared by mechanosynthesis  

International Nuclear Information System (INIS)

Nanocrystalline samples of Fe_8_0Mo_2_0 and Fe_5_0Mo_5_0 alloys were prepared by the mechanical milling method. The structure, lattice parameters, and crystallite size were determined by the X-ray diffraction. The magnetic properties of the milled products were determined by the Moessbauer spectroscopy. It was observed that in the case of the Fe_8_0Mo_2_0 alloy a solid solution of Mo in Fe was formed with the lattice parameters of the Fe increasing from 0.28659 nm to 0.29240 nm and the crystallite size decreasing from 250 nm to 20 nm. In the case of the Fe_5_0Mo_5_0 alloy there were no clear changes in values of the lattice parameters of Fe and Mo during the milling process, but the crystallite size decreased from 200 to 15 nm. Moessbauer spectra revealed different magnetic phases in the machanosynthesized Fe_Mo samples. In the case of the Fe_8_0Mo_2_0 alloy, the spectrum for the ...

2001-09-23

237

Fabrication and animal experiment of nanocomposites of hydroxyapatite collagen and polysaccharides  

Energy Technology Data Exchange (ETDEWEB)

Four species of nanocomposites organized by hydroxyapatite (HAp), hyaluronic acid (HyA), chondroitin sulfate (ChS) and type II collagen (Col), i.e. HAp/HyA, HAp/ChS, HAp/HyA/Col and HAp/ChS/Col composites, were synthesized by coprecipitation methods. The composites could retain lots of water: 40%, 32%, 42% and 58% for the HAp/HyA, HAp/ChS, HAp/HyA/Col and HAp/ChS/Col composites, respectively. Transmission electron microscopy observations revealed that the HAp/HyA and HAp/ChS composites consisted of island-like aggregations whose sizes were 300 nm in length and 30 nm in width, and 150 nm in length and 30 nm in width, respectively. In the aggregations, there were many HAp nanocrystals of 20 nm in length, and their c-axes were aligned along the respective polymer molecules through a self-organization process. Animal tests showed that chondrocyte-like cells penetrated into the ...

2001-07-01

238

Electrical properties of inalp native oxides for metal-oxide-semiconductor device applications  

Science.gov (United States)

Data are presented on the insulating properties and capacitance-voltage (CV) characteristics of metal-oxide-semiconductor (MOS) device-thickness (below approx. 100 nm) native oxides formed by wet thermal oxidation of thin InAlP epilayers lattice matched to GaAs. Low leakage current densities of J=1.4 x 10-9 A/cm2 and J=8.7 x 10-11 A/cm2 are observed at an applied field of 1 MV/cm for MOS capacitors fabricated with 17 nm and 48 nm oxides, respectively. TEM images show that the In-rich interfacial particles which exist in 110 nm oxides are absent in 17 nm oxide films. Quasi-static capacitance-voltage measurements of MOS capacitors fabricated on both n-type and p-type GaAs show that the InAlP oxide-GaAs interface is sufficiently free of traps to support inversion, indicating an unpinned Fermi level. These data suggest that InAlP native oxides may be a viable insulator for GaAs MOS ...

2004-09-01

239

Three-quasiparticle states in "1"7"7Ta  

International Nuclear Information System (INIS)

... transitions lutetium 175 target mev range 10-100 multipolarity neutrons parity

240

Terrorism Knowledge Base (TKB)  

Science.gov (United States)

... they assisted in the 2000 attack on the USS Cole? ... List the types of targets that ETA has attacked. ... was at least partially responsible for the attack. ...

2008-04-01

241

Surgical Counter-Terrorism: Targeting Individuals as an ...  

Science.gov (United States)

... Tanzania, and the attack on the USS COLE. ... vis another has no bearing on the legality of the attack. If the person attacked is a combatant, the use of ...

2003-02-03

242

Single-Walled Carbon Nanotubes Targeted to the Tumor ...  

Science.gov (United States)

... 1981. Retention of diphenyls, terphenyls, phenylalkanes and fluorene on graphitized thermal carbon black. Chromatographia 14:510-514. ...

2009-09-01

243

Review of Vaccinia Virus and Baculovirus Viability Versus ...  

Science.gov (United States)

... hazards. One study targeted the effects of common household disinfectants on virus inactivation (Butcher and Ulaeto, 2005). ...

2008-03-01

244

Production of polarized negative ion beams by collisional pumping  

Energy Technology Data Exchange (ETDEWEB)

The production of polarized negative ion beams by collisional pumping is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.

1983-01-01

245

Production of polarized negative ion beams by ''collisional pumping''  

Energy Technology Data Exchange (ETDEWEB)

The production of polarized negative ion beams by ''collisional pumping'' is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.

1984-03-01

246
248

Pairing effect in the nucleon transfer processes in quasi-elastic heavy ion scattering  

International Nuclear Information System (INIS)

... range krypton 86 reactions molybdenum 92 target probability quasi-elastic

1987-04-14

249

Market segmentation and targeting for real time pricing  

Energy Technology Data Exchange (ETDEWEB)

While there is growing interest in Real Time Pricing as a competitive tool, its adoption to date has been constrained by wariness on the part of many utilities and many of their customers. That wariness is not misplaced, for Real Time Pricing is not for everyone. In order for both utilities and their customers to benefit, the pricing system must be properly tailored for, and offered to, the appropriate audience. This paper discusses needs for identifying targets, implications of targeting of Real Time Pricing to various types of customers, and implications for design and marketing of such pricing systems. Examples from utility experiences are provided, and recommendations are offered for development of improved targeting of Real Time Pricing.

1996-03-01

250

Fragmentation of nuclei by particles and nuclei of intermediate and high energies  

Energy Technology Data Exchange (ETDEWEB)

The present state of investigations into the fragmentation of target nuclei by particles and nuclei of intermediate and high energies is reviewed.

1983-11-01

252

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

253

Electromagnetic excitations in nuclei: From photon scattering to photo-dissociation  

International Nuclear Information System (INIS)

... 98 target molybdenum 99 niobium 91 photoneutrons photonuclear reactions

2006-03-20

254

Effect of improved target designs on the "2"3"8Pu production at the Fast Flux Test Reactor  

International Nuclear Information System (INIS)

This paper present the results of a series of calculations made to determine the "2"3"8Pu production potential of several advanced target assembly designs in the Fast Flux Test Facility (FFTF). These calculations show that by using advanced target designs the intimately mix the "2"3"7Np target material with an yttrium hydride moderator, the FFTF has the potential of producing up to 30 kg of high-quality "2"3"8Pu per year.

1991-11-10

255

On the relationship between stacking process and resolution. 2; Jugo shori to bunkaino ni kansuru kiso kenkyu. 2  

Energy Technology Data Exchange (ETDEWEB)

With respect to concept of resolution in seismic exploration using the reflection method, detailed considerations were given on processes of forming the resolution as a result of arranging observation points at vibration transmitting and receiving points. In the discussion, numerical experiments were carried out, in which the scattering stacking process is applied in a model having one scatterer existing in homogeneous media. The experiments investigated an imaging formation process of the scatterer when arrangement of the vibration transmitting and receiving points were changed from a coarse condition to a dense condition while the number of transmitting and receiving points is being increased. Resolution is created if waveforms having finite frequencies are used as input, and the imaging is performed by utilizing the limited number of vibration receiving and transmitting points. If the concept of equi-travel plane is used ...

1997-05-27

256

Target space duality II: applications  

Energy Technology Data Exchange (ETDEWEB)

We apply the framework developed in Target space duality I: general theory. We show that both nonabelian duality and Poisson-Lie duality are examples of the general theory. We propose how the formalism leads to a systematic study of duality by studying few scenarios that lead to open questions in the theory of Lie algebras. We present evidence that there are probably new examples of irreducible target space duality.

2000-09-25

257

Gastrin releasing peptide (GRP) receptor targeted radiopharmaceuticals: A concise update  

Energy Technology Data Exchange (ETDEWEB)

The gastrin releasing peptide (GRP) receptor is becoming an increasingly attractive target for development of new radiolabeled peptides with diagnostic and therapeutic potential. The attractiveness of the GRP receptor as a target is based upon the functional expression of GRP receptors in several tumors of neuroendocrine origin including prostate, breast, and small cell lung cancer. This concise review outlines some of the efforts currently underway to develop new GRP receptor specific radiopharmaceuticals by employing a variety of radiometal chelation systems.

2003-11-01

258

Effluent reduction using pinch technology: Targets for reduction and capital costs for mass exchange networks  

Energy Technology Data Exchange (ETDEWEB)

This paper illustrates how the techniques developed by the authors for capital cost targeting of mass exchange networks can be applied to determination of capital investment targets for reduction in effluent for existing systems involving mass exchange. The results is an impact diagram which shows the relationship between effluent reduction and capital investment, indicating a region of limiting return on investment as well as the maximum possible reduction in effluent. (au)

1999-02-01

259

Development of a new secondary beam separator and a new gas-jet target at Kyushu University  

International Nuclear Information System (INIS)

In order to facilitate observations of low energy nuclear reactions, a new type recoil mass-separator together with a new gas-jet target system is being developed at the tandem accelerator facility in Kyushu University. The expected mass-resolving power of the separator is 220 for a solid angle of 10 msr and the practical thickness of the gas-jet target will exceed 0.1 atm#centre dot#cm for the light elements of H and He. (author).

1994-06-01

260

Detection device for high explosives  

Energy Technology Data Exchange (ETDEWEB)

A portable fiber optic detector that senses the presence of specific target chemicals by electrostatically attracting the target chemical to an aromatic compound coating on an optical fiber. Attaching the target chemical to the coated fiber reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.

1992-01-01

261

A Liquid Parahydrogen Target for the Measurement of a Parity-violating Gamma Asymmetry in Polarized Neutron Capture on Protons  

Energy Technology Data Exchange (ETDEWEB)

A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical ...

2010-05-01

262

48 CFR 952.226-73 - Energy Policy Act target group certification.  

Science.gov (United States)

...2010-10-01 2010-10-01 false Energy Policy Act target group certification...Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND FORMS SOLICITATION...Provisions and Clauses 952.226-73 Energy Policy Act target group...

2010-10-01

263

Study on high-resolution sequence stratigraphy framework of uranium-hosting rock series in Qianjiadian sag  

International Nuclear Information System (INIS)

The ore-hosting Yaojia Formation is composed of a set of braided stream medium-fine grained sediments. Guided by the basic theory of high-resolution sequence stratigraphy, and based on the core observation, the analysis of chemical composition of rocks, and data of natural potential logging and apparent resistivity logging, the authors have set up the high-resolution sequence stratigraphy framework of the ore-hosting Yaojia Formation, and discussed the relation of the stratigraphic structure of the middle cycle, as well as the paleotopography, the micro-facies to the formation of uranium deposit. (authors)

2005-07-01

264

RAPID DAMAGE ASSESSMENT FROM HIGH RESOLUTION IMAGERY  

Energy Technology Data Exchange (ETDEWEB)

Disaster impact modeling and analysis uses huge volumes of image data that are produced immediately following a natural or an anthropogenic disaster event. Rapid damage assessment is the key to time critical decision support in disaster management to better utilize available response resources and accelerate recovery and relief efforts. But exploiting huge volumes of high resolution image data for identifying damaged areas with robust consistency in near real time is a challenging task. In this paper, we present an automated image analysis technique to identify areas of structural damage from high resolution optical satellite data using features based on image content.

2008-07-01

265

New focal plane detector system for the broad range spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.

1984-01-01

266

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

267

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

268

The cross sections of (n, x) nuclear reactions on Pb and Bi at the neutron energy 14.6 MeV  

International Nuclear Information System (INIS)

... compton spectrometers cross sections energy resolution energy-level transitions

2000-06-14

269

Synthesizer Stability Evaluation - NASA Technical Report Server (NTRS)  

Science.gov (United States)

verified via high-resolution spectral density measurements using the Hadamard Variance. .... spectral density measurements were made with the HF5390 ...

270

Self-similarity in NMR Spectra: An Application in Assessing the Level of Cysteine  

UK PubMed Central (United Kingdom)

High resolution of NMR spectroscopic data of biosamples are a rich source of information on the metabolic response to physiological variation or pathological events. There are many advantages...Full Text Available

2010-01-01

271

Science Directed Spacecraft Autonomy for Mars Missions - detail  

Science.gov (United States)

The rapidly growing field of remote sensing is beginning to supply massive amounts of high resolution imagery of the earth and other planets. ...

272

Resolution studies of a GEM-based TPC  

Energy Technology Data Exchange (ETDEWEB)

Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 {mu}m, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons with a tunable energy between 1 GeV and 6 GeV. Using the independent measurement of the ...

2006-12-15

273

Reduced resolution polarimetric imagery characterization of the 1990 Galveston Bay oil spill  

Energy Technology Data Exchange (ETDEWEB)

Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a ...

1997-06-01

274

Postfire soil burn severity mapping with hyperspectral image unmixing  

Science.gov (United States)

Sep 28, 2011... to assess the application of high resolution imagery for burn severity mapping and to compare it to standard burn severity mapping methods. ...

275

PROBING NEAR-SURFACE ATMOSPHERIC TURBULENCE WITH LIDAR MEASUREMENTS AND HIGH-RESOLUTION HYDRODYNAMIC MODELS  

Energy Technology Data Exchange (ETDEWEB)

As lidar technology is able to provide fast data collection at a resolution of meters in an atmospheric volume, it is imperative to promote a modeling counterpart of the lidar capability. This paper describes an integrated capability based on data from a scanning water vapor lidar and a high-resolution hydrodynamic model (HIGRAD) equipped with a visualization routine (VIEWER) that simulates the lidar scanning. The purpose is to better understand the spatial and temporal representativeness of the lidar measurements and, in turn, to extend their utility in studying turbulence fields in the atmospheric boundary layer. Raman lidar water vapor data collected over the Pacific warm pool and the simulations with the HIGRAD code are used for identifying the underlying physics and potential aliasing effects of spatially resolved lidar measurements. This capability also helps improve the trade-off between spatial-temporal resolution ...

2000-11-01

277

NASA Satellite Measures Deforestation : Image of the Day  

Science.gov (United States)

Sep 14, 2005 ... For decades, the Brazilian government has been basing estimates of Amazon deforestation on high-resolution Landsat satellite data. Having ...

278

N-Body Code with Adaptive Mesh Refinement  

CERN Document Server

We have developed a simulation code with the techniques which enhance both spatial and time resolution of the PM method for which the spatial resolution is restricted by the spacing of structured mesh. The adaptive mesh refinement (AMR) technique subdivides the cells which satisfy the refinement criterion recursively. The hierarchical meshes are maintained by the special data structure and are modified in accordance with the change of particle distribution. In general, as the resolution of the simulation increases, its time step must be shortened and more computational time is required to complete the simulation. Since the AMR enhances the spatial resolution locally, we reduce the time step locally also, instead of shortening it globally. For this purpose we used a technique of hierarchical time steps (HTS) which changes the time step, from particle to particle, depending on the size of the cell in ...

2001-01-01

280

High resolution (p,p') reactions on "8"7Sr and "8"8Sr  

International Nuclear Information System (INIS)

... levels excited states mev range 10-100 proton reactions proton spectra protons

281

High Resolution Modeling of Coastal Inundation: User ...  

Science.gov (United States)

... Ruth. Preller@nrlssc.navy.mil 76 Marine Technology Society Journal Page 4. ... 78 Marine Technology Society Journal Page 6. ...

2007-07-27

282

Clinical spectrum  

Energy Technology Data Exchange (ETDEWEB)

A tunable diode laser is used to obtain infrared spectra of carbon dioxide in biological materials. The spectral resolution is sufficient to readily distinguish differing isotopic species. The technique may prove useful in clinical tests.

1987-11-01

283

Chronic Disability Syndrome  

UK PubMed Central (United Kingdom)

Prolonged disability is best understood as an illness that exists independently of the initiating disease. The disabled individual goes through predictable stages of disability before resolution occurs....Full Text Available

1991-09-01

284

C-CAP Land Cover, Commonwealth of the Northern Mariana Islands (CNMI), Farallon de Pajaros, 2004  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

285

C-CAP Land Cover, Commonwealth of the Northern Mariana Islands (CNMI), Anatahan, 2005  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

286

C-CAP Land Cover, Commonwealth of the Northern Mariana Islands (CNMI), Aguijan, 2003  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

287

Benefits of Using the Photosimulation Laboratory Environment ...  

Science.gov (United States)

... with the ability to capture imagery in raw 24-bit format, combined with large memory storage devices enable high resolution imagery to be captured ...

2002-08-01

288

Acquisition of a High Resolution Field Emission Scanning Electron Microscope for the Analysis of Returned Samples  

Science.gov (United States)

This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to

2003-01-01

289

APOD: April 25, 1996 - In the Center of the Whirlpool  

Science.gov (United States)

picture will download the highest resolution version available. In the Center of the Whirlpool Credit: N. Panagia (STScI, ESA), NASA Explanation: In the center of M51, a spiral...

2011-10-07

290

APOD: 2011 June 11 - Supernovae in the Whirlpool  

Science.gov (United States)

the picture will download the highest resolution version available. Supernovae in the Whirlpool Image Credit & Copyright: R Jay Gabany Explanation: Where do spiral galaxies keep...

2011-10-07

291

APOD: 2009 May 26 - Whirlpool Galaxy Deep Field  

Science.gov (United States)

Clicking on the picture will download the highest resolution version available. Whirlpool Galaxy Deep Field Credit & Copyright: Jon Christensen Explanation: Follow the handle...

2011-10-07

292

APOD: 2005 November 25 - Moon Over Antarctica  

Science.gov (United States)

on the picture will download the highest resolution version available. Moon Over Antarctica Credit & Copyright: James Behrens (IGPP, Scripps Institution of Oceanography)...

2011-10-14

293

APOD: 2002 July 10 - M51: Cosmic Whirlpool  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: Cosmic Whirlpool Credit & Copyright: Tony and Daphne Hallas Explanation: Follow the handle of the Big...

2011-10-07

294

APOD: 2000 July 24 - M51: The Whirlpool Galaxy  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: The Whirlpool Galaxy Credit & Copyright: Todd Boroson (NOAO), AURA, NOAO, NSF Explanation: The...

2011-10-07

295

A setup for high-resolution isotope shift measurements on unstable lithium isotopes  

Energy Technology Data Exchange (ETDEWEB)

We present a laser spectroscopic approach for measuring the charge radius of the halo nucleus {sup 11}Li and report on recent progress in the development of the experimental apparatus.

2003-05-01

296

49 CFR 240.405 - Processing qualification review petitions.  

Science.gov (United States)

...Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION QUALIFICATION AND CERTIFICATION OF LOCOMOTIVE ENGINEERS Dispute Resolution Procedures § 240.405 Processing qualification review petitions. (a)...

2010-10-01

297

2010 NASA Terrestrial Ecology Science Team Meeting - NASA Carbon ...  

Science.gov (United States)

The biomass maps were compared with the U.S. Forest Service biomass map for 2002 , LVIS height data, and estimates from high resolution imagery. ...

298

2002 C-CAP Land Cover, Territory of American Samoa, Swains  

Science.gov (United States)

This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change ... ...

299

Selection of IFE target materials from a safety and environmental perspective  

International Nuclear Information System (INIS)

Target materials for inertial fusion energy (IFE) power plant designs might be selected for a wide variety of reasons including wall absorption of driver energy, material opacity, cost and ease of fabrication. While each of these issues are of great importance, target materials should also be selected based upon their safety and environmental (S and E) characteristics. The present work focuses on the recycling, waste management and accident dose characteristics of potential target materials. If target materials are recycled so that the quantity is small, isotopic separation may be economically viable. Therefore, calculations have been completed for all stable isotopes for all elements from lithium to polonium. The results of these calculations are used to identify specific isotopes and elements that are most likely to be offensive as well as those most likely to be acceptable in terms of their S and E ...

2001-05-21

300

Mode of action of membrane-disruptive lytic compounds from the marine dinoflagellate Alexandrium tamarense  

British Library Electronic Table of Contents (United Kingdom)

Certain allelochemicals of the marine dinoflagellate Alexandrium tamarense cause lysis of a broad spectrum of target protist cells but the lytic mechanism is poorly defined. We first hypothesized that membrane sterols serve as molecular targets of these lytic compounds, and that differences in sterol composition among donor and target cells may cause insensitivity of Alexandrium and sensitivity of targets to lytic compounds. We investigated Ca^2^+ influx after application of lytic fractions to a model cell line PC12 derived from a pheochromocytoma of the rat adrenal medulla to establish how the lytic compounds affect ion flux associated with lysis of target membranes. The lytic compounds increased permeability of the cell membrane for Ca^2^+ ions even during blockade of Ca^2^+ channels wit...

2011-01-01

301

An identification method of positron production in laser beam interaction with targets  

Energy Technology Data Exchange (ETDEWEB)

A simple electromagnetic transport system was constructed to identify very rare positrons produced in a powerful laser beam interaction with a target. Testing experiments were carried out with CO[sub 2]-laser (10[sup 12] W/cm[sup 2]) beam pulses ([tau] = 50 ns, f = 0.01 Hz) focused on the copper target, as well as with a 96 MeV alpha-particle beam irradiated carbon target. The results showed that the developed system could be effectively used for positron identification and evaluation of their energy by means of a time-of-flight method. The computerized system to deal with this problem, together with others related to the power laser beam interaction with targets, has been constructed. (orig.).

1992-10-01

302

Activation analysis of target debris in the national ignition facility  

International Nuclear Information System (INIS)

The modeling methods used to compute the neutron-induced activation of target and near-target materials in the NIF facility are presented. A detailed space and energy description of the neutron environment in the different materials is provided. A new capability has been developed to treat in a general way the activation of debris produced in an operational regime of yield and no-yield experiments. First calculations are addressed to analyze the activity of the debris into the target chamber. The contribution of the different components to activity, interior dose rates, and waste disposal rating (WDR) is determined. The importance of the activation coming from primary irradiation in the target, and from secondary irradiation in debris deposited onto the first wall is assessed. Finally, waste hazards of the activated debris when removed out of the chamber and stored are analyzed. (authors)

1999-09-12

303

In vitro toxicity of silica nanoparticles in human lung cancer cells  

International Nuclear Information System (INIS)

The cytotoxicity of 15-nm and 46-nm silica nanoparticles was investigated by using crystalline silica (Min-U-Sil 5) as a positive control in cultured human bronchoalveolar carcinoma-derived cells. Exposure to 15-nm or 46-nm SiO_2 nanoparticles for 48 h at dosage levels between 10 and 100 #mu#g/ml decreased cell viability in a dose-dependent manner. Both SiO_2 nanoparticles were more cytotoxic than Min-U-Sil 5; however, the cytotoxicities of 15-nm and 46-nm silica nanoparticles were not significantly different. The 15-nm SiO_2 nanoparticles were used to determine time-dependent cytotoxicity and oxidative stress responses. Cell viability decreased significantly as a function of both nanoparticle dosage (10-100 #mu#g/ml) and exposure time (24 h, 48 h, and 72 h). Indicators of oxidative stress and cytotoxicity, including total reactive oxygen ...

2006-12-15

304

FABRICATION OF BISMUTH NANOWIRE DEVICES USING FOCUSED ION BEAM MILLING  

International Nuclear Information System (INIS)

In this work, a focused ion beam (FIB) milling process has been developed to fabricate 50 nm Bi nanowire and transistor structures using FEI-200 dual beam FIB system. For the fabrication, 50 nm bismuth film was thermally evaporated through EBL patterned PMMA windows onto SiO_2 substrates with pre-defined contact pads. Bi nanowire widths ranging from 30 nm to 100 nm have been successfully fabricated by milling out unwanted areas using 30 KeV Ga+ ion beam. A single-pixel-line ion beam blanking technique has been utilised to fabricate Bi nanowire as small as 30 nm in diameter and few micrometers long. In order to form good ohmic contacts for sub 50 nm bismuth nanowires, a drill-and-fill process has been developed using FIB to sputter away the surface oxide of bismuth after the in-situ platinum nanowire contacts deposition. To our knowledge, this is the first time a ...

2009-07-23

305

[Improvement of the recognition probability about camouflage target based on BP neural network].  

Science.gov (United States)

Using static Michelson interferometer to get the spectrum information of measurement targets for spectrum identification, under the condition that the interference length is constant, the system can be optimized by BP neural network algorithm for the mixed spectral separation process. Thereby it can realize improving the recognition probability of camouflage target. Collecting the spectrum information in field of view (FOV) by the interferometer and linear array CCD detector, composing the set of mixed spectrum data, with known absorption spectrum of the material as a hidden layer of rules, it used BP neural network to separate the mixed spectrum data. Experiment with different distances, different combinations of mixed background spectrum as the initial data, using steel target (size: 1.5 m x 1.5 m) made of four kinds, the recognition probability of non-camouflage target is about 90% by BP neural ...

2010-12-01

306

Traffic and transport in the Dutch National Environmental Outlook 4; Verkeer en vervoer in de Nationale Milieuverkenning 4  

Energy Technology Data Exchange (ETDEWEB)

In the Fourth Dutch National Environmental Outlook (NMP, abbreviated in Dutch) of the National Institute of Public Health and the Environment (VROM), published in July 1997, possible future developments in the traffic and transport sector in the Netherlands are described for the period 1995-2020 and also evaluates present Dutch policies. NMP-4 also offers possible solutions for expected environmental problems. This report serves as a background document for the traffic and transport sector. With a view to present Dutch policies, the main conclusions drawn from the Outlook are that: (1) the policy targets for car and lorry use for 2010 will not be met, (2) the target for CO2 emissions from road transport for 2010 will not be met, (3) the NOx emission target for 2010 will be met for cars, but not for trucks, (4) the VOC emission target for 2010 will be met for cars, but not for trucks, and (5) the noise ...

1998-03-01

307

Up-conversion luminescence saturation under pulsed excitation of erbium-doped, SiO_2-TiO_2 sol-gel powders  

International Nuclear Information System (INIS)

The intensity of erbium up-conversion luminescence could be limited by a saturation effect due to increased pump power. We studied the luminescence saturation of the 550 nm emission on erbium-doped, SiO_2-TiO_2 sol-gel powders under pulsed excitation at 979 and 1532 nm. From the latter, the up-converted luminescence intensity decreased with increasing excitation power, whereas no saturation was observed at 979 nm excitation. We proposed that the saturation effect is determined by the pump power, the erbium content and the lifetime of the corresponding first excited states at different pumping schemes.

2010-12-01

308

Thin-film UV detectors based on hydrogenated amorphous silicon and its alloys  

Energy Technology Data Exchange (ETDEWEB)

Thin film ultraviolet detectors based on hydrogenated amorphous silicon alloys are realized with different diode structures (PIN, NIP, PN, and NP). The PIN and NIP detectors exhibit higher sensitivity in the ultraviolet spectrum and a significant lower dark current in comparison to the PN or NP structures. The best detector performance was achieved with a 33 nm thick PIN diode. This detector shows a maximum of quantum efficiency of 36.3% at a wavelength of 310 nm. By varying the thickness of the semi-transparent Ag front contact the selectivity of the detectors with the quantum efficiency peak at 320 nm can be adjusted. Thus, the spectral sensitivity of the detector shifts from a broad UV to a selective UV-B spectrum. (orig.)

2001-05-16

309

Synthesis and photoluminescence properties of continuous freestanding SiC(Al) films derived from aluminum-containing polycarbosilane  

International Nuclear Information System (INIS)

Continuous freestanding SiC(Al) films were fabricated by melt spinning the aluminum-containing polycarbosilane (A-PCS) precursor. The results showed that the films contained #beta#-SiC crystals, #alpha#-SiC nano-crystals, C clusters and small amount of Al_4O_4C and Al_4SiC_4. The Al atoms in the films played important roles as both sintering aids and grain growth inhibitor. The PL spectrum showed a wide luminescence band from 320 nm to 440 nm, and the origin of PL centered at 385 nm might be related to the #alpha#-SiC nano-crystals using quantum size effects. The obtained films are expected to have important applications in MEMS for the environment of high temperature and optoelectronic devices.

2010-10-01

310

Synthesis and enhanced light absorption of alumina matrix nanocomposites containing multilayer oxide nanorods and silver nanoparticles  

British Library Electronic Table of Contents (United Kingdom)

In this paper, multilayer oxide nanorods were deposited in the nanopores of anodic aluminum oxide (AAO) via solution infiltration followed by heat treatment. The nanorods have a core-shell structure. First, the shell (nanotube) with the thickness of about 40nm was made of TiO"2 through the hydrolysis of (NH"4)"2TiF"6. Second, silver nanoparticles with the diameter of about 3nm were added into the TiO"2 layer through thermal decomposition of AgNO"3 at elevated temperatures. Then, cylindrical cores (nanorods) of CoO and ZnO with 200nm diameter were prepared, respectively. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to characterize the structure and composition of the nanorods. UV-vis light absorption measurements in the wavelength range from 350 to...

2011-01-01

311

Structure and properties of Li2Zn2(MoO4)3 crystals activated with copper and chromium ions  

British Library Electronic Table of Contents (United Kingdom)

Based on the corrected phase diagrams proper growth conditions for Li2Zn2(MoO4)3 crystals are selected. Large crystals (up to 100 mm), both impurity-free and activated by transition metal ions (Cu, Cr), are grown by the low-gradient Czochralski method. By the EPR method the charge state and structural position of copper and chromium ions are determined. The performed studies of luminescent properties show that for impurity-free crystals luminescence with ? = 388 nm with a two-exponential luminescence decay with ?1 = 2 ns and ?2 = 6 ns is observed at room temperature. At 77 K for both impurity-free crystals and those activated with transition metal ions luminescence with ? = 560 nm and the luminescence lifetime ? = 100 ns is observed, the intensity of luminescence with ? = 560 nm depending ...

2011-01-01

312

Optimizing boron junctions through point defect and stress engineering using carbon and germanium co-implants  

International Nuclear Information System (INIS)

We report the fabrication of p"+/n junctions using Ge"+, C"+, and B"+ co-implantation and a spike anneal. The best junction exhibits a depth of 26 nm, vertical abruptness of 3 nm/decade, and sheet resistance of 520 Ohm/square. The junction location is defined by where the boron concentration drops to 10"1"8 cm"-"3. These junctions are close to the International Technology Roadmap specifications for the 65 nm technology node and are achieved by careful engineering of amorphization, stresses, and point defects. Advanced simulation of boron diffusion is used to understand and optimize the process window. The simulations show that the optimum process completely suppresses the transient-enhanced diffusion of boron and the formation of boron-interstitial clusters. This increases the boron solubility to 20% above the equilibrium solid-state solubility.

2005-08-01

313

Optical properties and up-conversion of Pr"3"+ doped CdS nanoparticles in sol-gel glasses  

International Nuclear Information System (INIS)

Silica glasses containing Pr"3"+ with and without CdS nanoparticles were prepared by sol-gel technique. The influence of CdS nanoparticles on Pr"3"+ doped glass was studied by absorption, photoluminescence and up-conversion. From the measured intensities of various absorption bands of these glasses, the Judd-Ofelt parameters ?_2, ?_4 and ?_6 have been evaluated. The radiative transition probability (A), radiative lifetime (?_R), branching ratio (?_R) and integrated emission cross-section (?_P) were calculated from excited states of "3P_1 and "3P_0 levels. The up-conversion emissions were found in the green, orange and red regions under 800 nm excitation with peaks 559, 612 and 688 nm respectively. On excitation with 370 nm also leads to similar green, orange and red regions.

2010-10-01

314

On the interaction of vanadium (4) with derivatives 3,4,5-trihydroxy-isoxanthene  

International Nuclear Information System (INIS)

A study was made on interaction of vanadium (4) ions with dyes-pyrogallol red, brompyrogallol red and gallein- in the range of pH = 0-6. The maximal light absorption for gallein and brompyrogallol red is observed at pH=4 and #lambda#max = 545 nm and 560 nm respectively. The compound of vanadium (4) with pyrogalloe red is characterized by the maximal light absorption at pH=5 and #lambda#max=560 nm. Component ratio in all analyzed compounds is equal to 1:2. Molar extinction coefficients for compounds with gallein, pyrogallol red and brompyrogallol red are equal to 5000, 550 and 7400, and logarithms of stability constants - to 9.27, 13.17 and 13.25 respectively.

315

Microtiter plate assay for phosphate using a europium-tetracycline complex as a sensitive luminescent probe  

Energy Technology Data Exchange (ETDEWEB)

A new luminescent europium probe is presented for the determination of phosphate (P) in microtiter plate format. The assay is based on the quenching of the luminescence of the europium-tetracycline (EuTc) 1:1 complex by phosphate using a reagent concentration of 20.8 {mu}mol/L. The probe is excited at 400 nm and displays a large Stokes' shift of 210 nm. The emission maximum is located at 616 nm. The system works best at neutral pH 7 and is therefore suitable for phosphate determination in biological and biochemical systems. The linear range of the calibration plot is from 5 x 10{sup -6} mol/L to 7.5 x 10{sup -4} mol/L of phosphate, and the limit of detection is 3 {mu}mol/L.

2006-01-12

316

Long range ordering in self-assembled Ni arrays on patterned Si  

Energy Technology Data Exchange (ETDEWEB)

We have succeeded in aligning self-assembled structures by using a lithographically defined stripe. The 140 nm wide by 100 nm high SiO{sub 2} strip is shown to guide the assembly of 500 nm latex spheres so that spheres are aligned along the strip and are in registration on either side of the strip. This method can be used to increase long-range ordering in magnetic storage systems without compromising the density. Inverse sphere Ni arrays were made by electrodeposition through the latex template. We also show that the hexagonal symmetry of the resulting inverse sphere Ni arrays can be simulated using the approach presented below.

2007-09-15

317

Long range ordering in self-assembled Ni arrays on patterned Si  

International Nuclear Information System (INIS)

We have succeeded in aligning self-assembled structures by using a lithographically defined stripe. The 140 nm wide by 100 nm high SiO_2 strip is shown to guide the assembly of 500 nm latex spheres so that spheres are aligned along the strip and are in registration on either side of the strip. This method can be used to increase long-range ordering in magnetic storage systems without compromising the density. Inverse sphere Ni arrays were made by electrodeposition through the latex template. We also show that the hexagonal symmetry of the resulting inverse sphere Ni arrays can be simulated using the approach presented below.

2007-09-01

318

Long range ordering in self-assembled Ni arrays on patterned Si  

British Library Electronic Table of Contents (United Kingdom)

We have succeeded in aligning self-assembled structures by using a lithographically defined stripe. The 140nm wide by 100nm high SiO2 strip is shown to guide the assembly of 500nm latex spheres so that spheres are aligned along the strip and are in registration on either side of the strip. This method can be used to increase long-range ordering in magnetic storage systems without compromising the density. Inverse sphere Ni arrays were made by electrodeposition through the latex template. We also show that the hexagonal symmetry of the resulting inverse sphere Ni arrays can be simulated using the approach presented below.

2007-01-01

319

Impact of Collateral Damage to Endourologic Tools During Laser Lithotripsy???In Vitro Comparison of Three Different Clinical Laser Systems  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background and Purpose: During laser lithotripsy, working instruments are often in close proximity to the distal fiber tip and may be damaged accidentally or even intentionally. The aim of this study was to compare the amount of damage to a standard guidewire and the nitinol wires of endourologic retrieval baskets that were affected by three different clinically available laser systems. Materials and Methods: The impact of pulsed laser irradiation on a standard hydrophilic guidewire and a retrieval basket were investigated. One infrared (IR) laser system (holmium:yttrium-aluminum-garnet [Ho:YAG]: ????=???2100???nm) and two laser systems emitting light in the visible (VIS) spectral range (frequency-doubled double-pulse neodymium:YAG [FREDDY]: ????=???532???nm/1064???nm and flashl...

2011-01-01

320

Experimental demonstration of three-color entanglement  

CERN Document Server

Entanglement is the essential quantum resource for a potential speed-up of information processing, as well as for sophisticated quantum communication. Quantum information networks will be required to convey information from one place to another, by using entangled light beams. Many physical systems are under consideration as building blocks, with different merits and faults, so that hybrid systems are likely to be developed. Here we present an important tool for connecting systems that share no common resonance frequencies: we demonstrate the first direct generation of entanglement among more than two bright beams of light, all of different wavelengths (532.251 nm, 1062.102 nm, and 1066.915 nm). We also observe, for the first time, disentanglement for finite channel losses, the continuous variable counterpart to entanglement sudden death.

2010-01-01

321

Electrochemical method for the synthesis of silver nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

The article deals with a novel electrochemical method of preparing long-lived silver nanoparticles suspended in aqueous solution as well as silver powders. The method does not involve the use of any chemical stabilising agents. The morphology of the silver nanoparticles obtained was studied using transmission electron microscopy, scanning electron microscopy, atomic force microscopy and dynamic light scattering measurements. Silver nanoparticles suspended in water solution that were produced by the present technique are nearly spherical and their size distribution lies in the range of 2 to 20 nm, the average size being about 7 nm. Silver nanoparticles synthesised by the proposed method were sufficiently stable for more than 7 years even under ambient conditions. Silver crystal growth on the surface of the cathode in the electrochemical process used was shown to result in micron-sized structures consisting of agglomerated silver nanoparticles ...

2009-07-15

322

Coloring of cultured pearls by gamma-rays irradiation  

International Nuclear Information System (INIS)

Changing cream pearls into bluish-grey by #gamma# ray irradiation is a technique in coloring of pearls. Irradiated pearls are similar in color to cultured blue pearls. The pearl layers hardly change their color but the nuclei change into dark brown by irradiation. Visible light (500 - 700 nm) penetrating the pearl layer is absorbed by dark brown nucleus. The intensity of reflecting light between 400 and 500 nm at pearl surface, therefore, becomes stronger than that between 500 and 700 nm; therefore color of irradiated pearls look bluish-grey. The density of bluish-grey color increases with increasing absorbed doses, but their luster at surface diminishes owing to the deterioration of the pearl layer by prolonged irradiation; high doses irradiation should be avoided. Irradiated pearls show no substantial fading of their color in a year and the rate of the fading is found to be lower than that for cultured blue pearls. ...

323

Cancers | Special Issue: Advances and Research Progress in Hepatocellular Carcinoma  

Wastenet

...comAbstract: Hepatocellular carcinoma (HCC), once thought to be a rare tumor in North America, is a rapidly increasing type of cancer in recent years in the United States. Current treatment modalities to halt the disease progression are only marginally effective. The mainstay treatment ...In addition, NM was shown to down-regulate urokinase plasminogen activator (by fibrin zymography) and up-regulate tissue inhibitors of metalloproteinases (by reverse zymography) in another HCC cell line, Sk-Hep-1. MMP-2 and MMP-9 activities were further modulated by cytokines, inducers and inhibitors, including NM. In ... Our results suggest that NM is an excellent candidate for therapeutic use in the treatment HCC by inhibiting critical parameters in cancer development and progression, such as proliferation, invasion and metastasis, and by inducing apoptosis. Last update: 2 September 2011 JavaScript seems ...

324

Broad-linewidth laser absorption measurements of oxygen between 211 and 235nm at high temperatures  

British Library Electronic Table of Contents (United Kingdom)

Absorption coefficient data are presented for molecular oxygen at temperatures between 1100 and 2000K and discrete wavelengths between 211 and 235nm. Measurements were made behind reflected shock waves using broad-linewidth ultraviolet laser radiation generated from a frequency-quadrupled, tunable, pulsed Ti:Sapphire laser. Test mixtures consisting of 15% O"2, 15% He and balance Ar were used to minimize the influence of vibrational relaxation on the reflected shock temperature. The experimental results are in good agreement with theoretical calculations and confirm that discrete features from the Schumann-Runge system dominate between 211 and 235nm at temperatures higher than 1100K.

2011-01-01

325

AlGaInP visible vertical cavity surface emitting lasers operating with gain contributions from the [ital n]=2 quantum well transition  

Science.gov (United States)

We report the characteristics of visible vertical cavity surface emitting laser diodes. Wafers are grown such that the Fabry--Perot resonance wavelength changes with position from 690 to 620 nm, overlapping to varying degrees with the [ital n]=1 and [ital n]=2 quantum well gain peaks at [similar to]670 and 650 nm. Gain guided devices are tested across the entire wafer, and pulsed room temperature lasing is observed from 634.6 to 663.2 nm. Our results suggest that gain contributions from the second quantized state are required to overcome high cavity losses in order to achieve lasing.

1993-12-20

326

Performance of a large Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.

1987-04-01

327

Performance of a large Bragg-curve spectrometer  

International Nuclear Information System (INIS)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).

328

Metabolomics in Lung Inflammation: A High Resolution 1H NMR Study of Mice Exposed to Silica Dust  

UK PubMed Central (United Kingdom)

Here we report the first 1H NMR metabolomics studies on excised lungs and bronchoalveolar lavage fluid (BALF) from mice exposed to crystalline silica. High resolution 1H...Full Text Available

2008-01-01

329

High resolution neutron imaging of water in the polymer electrolyte fuel cell membrane  

Energy Technology Data Exchange (ETDEWEB)

Water transport in the ionomeric membrane, typically Nafion{reg_sign}, has profound influence on the performance of the polymer electrolyte fuel cell, in terms of internal resistance and overall water balance. In this work, high resolution neutron imaging of the Nafion{reg_sign} membrane is presented in order to measure water content and through-plane gradients in situ under disparate temperature and humidification conditions.

2009-01-01

330

High resolution imagery of the clumpy irregular galaxy Markarian 325 = NGC 7673  

Energy Technology Data Exchange (ETDEWEB)

High resolution imagery of the clumpy irregular galaxy Mkn 325 shows that some clumps have sizes approximately 300 pc while some may still be unresolved and approximately < 100 pc. In spite of dimensions comparable to - or even smaller than - those of the giant H II complex 30 Doradus, one clump has a star formation rate 100 times higher.

1982-05-01

331

High resolution imagery of the clumpy irregular galaxy Markarian 325 = NGC 7673  

International Nuclear Information System (INIS)

High resolution imagery of the clumpy irregular galaxy Mkn 325 shows that some clumps have sizes approximately 300 pc while some may still be unresolved and approximately < 100 pc. In spite of dimensions comparable to - or even smaller than - those of the giant H II complex 30 Doradus, one clump has a star formation rate 100 times higher. (author).

332

Field-portable lensfree tomographic microscope.  

Science.gov (United States)

We present a field-portable lensfree tomographic microscope, which can achieve sectional imaging of a large volume (?20 mm(3)) on a chip with an axial resolution of Hymenolepis nana egg, which is an infectious parasitic flatworm. Achieving a decent three-dimensional spatial resolution, this field-portable on-chip optical tomographic microscope might provide a useful toolset for telemedicine and high-throughput imaging applications in resource-poor settings. PMID:21573311

2011-05-16

333

Ewald sphere correction for single-particle electron microscopy  

Energy Technology Data Exchange (ETDEWEB)

Most algorithms for three-dimensional (3D) reconstruction from electron micrographs assume that images correspond to projections of the 3D structure. This approximation limits the attainable resolution of the reconstruction when the dimensions of the structure exceed the depth of field of the microscope. We have developed two methods to calculate a reconstruction that corrects for the depth of field. Either method applied to synthetic data representing a large virus yields a higher resolution reconstruction than a method lacking this correction.

2006-03-15

334

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

Energy Technology Data Exchange (ETDEWEB)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.

1987-03-01

335

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).

1987-01-01

336

Bragg curve spectroscopy detector for particle identification  

International Nuclear Information System (INIS)

The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.

337

A high-sensitivity small animal SPECT system  

International Nuclear Information System (INIS)

Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity receptor systems, aiding research into ...

2009-03-07

338

Study of spatial resolution in three-dimensional rotational angiography  

International Nuclear Information System (INIS)

In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be as high as 0.75 mm. When the slit phantom was placed orthogonal to the rotational axis of the C-arm, the spatial resolution of 3D-RA was decreased ...

2006-03-01

339

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from ...

2008-02-01

340

High resolution Computed Tomography in the study of temporal bone trauma  

International Nuclear Information System (INIS)

Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to ...

1988-01-01

341

Is uniform target dose possible in IMRT plans in the head and neck?  

International Nuclear Information System (INIS)

Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition dose ...

2002-04-01

342

Variation in the action spectrum of erythrolabe among deuteranopes.  

UK PubMed Central (United Kingdom)

1. Eight deuteranopes matched a mixture of a monochromatic light on the long wave side of the neutral point and a violet (450 nm) primary to a fixed white as well as a monochromatic light on the short...Full Text Available

1977-04-01

343

Urea: An important piece of Water Soluble Organic Nitrogen (WSON) over the Eastern Mediterranean  

British Library Electronic Table of Contents (United Kingdom)

The role of atmospheric urea on the biogeochemical cycle of Water Soluble Organic Nitrogen (WSON) in the Eastern Mediterranean was assessed by collecting and analyzing wet and dry deposition samples and size segregated aerosols during a one year period (2006). In rain water volume weighted mean (VWM) concentration of urea was found equal to 5.5mM. In atmospheric particles the average concentration of urea in coarse and fine mode was 0.9+/-1.9nmolNm^-^3 (median 0.0nmolNm^-^3) and 2.2+/-3.0nmolNm^-^3 (median 1.1nmolNm^-^3), respectively. The percentage contribution of urea to WSON fraction was 0% and 20% in coarse and fine particles respectively. On an annual basis 0.81mmolm^-^2 and 1.78mmolm^-^2 of urea were deposited via wet and dry deposition, contributing to WSON by 10% and 11% respectiv...

2011-01-01

344

Ultrafast carrier dynamics of InGaAsN and InGaAs single quantum wells  

International Nuclear Information System (INIS)

Striking differences in differential reflectance and carrier relaxation in In0.4Ga0.6As and In0.4Ga0.6As0.98N0.02 single quantum wells (SQWs) were studied using ultrafast time-resolved photoreflectance. Even with extremely thin SQW of only 60 A within 3000 A wide GaAs confining layers, negative and positive differential reflectance was observed for the excitation photon energy far above the bandgaps at 820 and 880 nm for both samples. Due to absorption by the GaAs confining layer, the peak differential reflectance pumped at 820 nm is an order of magnitude larger than that pumped at 880 nm; and it is larger for InGaAs SQWs than for InGaAsN SQWs. The shorter carrier lifetimes of these samples result from carrier-carrier scattering as pumped at both wavelengths. The longer carrier lifetime as pumped at 880 nm is due to hot phonon decay in InGaAs but may be due to stimulated emission in InGaAsN. The results ...

2008-04-21

345

Treatment of proliferative haemangiomas with the 585 nm pulsed dye laser.  

Science.gov (United States)

Haemangiomas usually develop within the first few weeks of life, most regressing spontaneously before the age of 7 years. Some may ulcerate or compromise a vital function, in which case systemic corticosteroids, surgery or radiotherapy may be helpful. All of these treatment modalities are associated with significant morbidity. Treatment with the 585 nm flashlamp pulsed dye laser is safe and effective in the management of superficial vascular malformations. We report seven patients, under 12 months of age, who presented with proliferative haemangiomas, causing functional impairment. Ulcerated lesions were present in four patients. The patients were treated with the 585 nm pulsed dye laser (fluences 7.0-9.25 J/cm2), at intervals of 4-8 weeks. All of the lesions showed a significant reduction in size, together with improvement in the colour and integrity of the overlying skin. Treatment with the 585 nm pulsed dye laser should ...

1996-04-01

346

The inhomogeneous structure of water at ambient conditions  

UK PubMed Central (United Kingdom)

Small-angle X-ray scattering (SAXS) is used to demonstrate the presence of density fluctuations in ambient water on a physical length-scale of ≈1 nm; this is retained with decreasing temperature...Full Text Available

2009-09-08

347

Spectrophotometric determination of vanadium(V) with 2-carbethoxy-5-hydroxy-1-(4-tolyl)-4-pyridone  

International Nuclear Information System (INIS)

Vanadium(V) in aqueous HCl, HNO_3 or H_2SO_4 solutions is extracted with 2-carbethoxy-5-hydroxy-1-(4-tolyl)-4-pyridone (HA) dissolved in CHCl_3 and determined spectrophotometrically, Depending on the composition of the aqueous phase, two complexes are formed. At pH 1 (HCl, HNO_3, H_2SO_4) VO_2A(HA)_2 is formed with maximal absorption at 478 nm. However, from 4-5 M HCl, VO_2Cl(HA)_3 is extracted, and has maximal absorption at 615 nm. The same complex is extracted from 2-3 M HNO_3 or 3-4 M H_2SO_4 if enough chloride is added. Solutions of both complexes follow Beer's law and the molar extinction coefficients are 4.15x10"3 1.mole"-"1cm"-"1 at 478 nm and 5.10x10"3 at 615 nm. The determination of vanadium at both wavelengths is very simple, fast and selective. The composition of the complexes was established by the usual methods as well as by characterization of the isolated crystalline compounds by ...

1975-01-01

348

Simulation study of chiral two dimensional ultraviolet (2DUV) spectroscopy of the protein backbone  

UK PubMed Central (United Kingdom)

Amide n –π* and π-π* excitations around 200 nm are prominent spectroscopic...Full Text Available

2010-06-09

349

Raman and SERS recognition of ?-carotene and haemoglobin fingerprints in human whole blood.  

Science.gov (United States)

The present work reports on Raman and Surface Enhanced Raman Scattering (SERS) vibrational fingerprints of ?-carotene and haemoglobin in fresh whole blood (i.e. right after blood test) with different laser excitations, i.e. visible (514 nm) and near-infrared (NIR, 785 nm). The use of colloidal silver nanoparticles significantly increases the Raman signal, thus providing a clear SERS spectrum of blood. The collected spectra have been examined and marker bands of ?-carotene and of the haem prosthetic group of haemoglobin have been found. In particular, the fundamental features of ?-carotene (514 nm excitation), blood proteins and haem molecules (785 nm excitation) were recognized and assigned. Moreover haemoglobin SERS signals can be identified and related with its oxygenation state (oxy-haemoglobin). The data reported show the prospects of Raman and SERS techniques to detect important bio-molecules in a ...

2011-03-26

350

Preparation of Eu-doped #beta#- and 15R-SiAlONs by ammonia nitridation of the precursor obtained using aluminum glycine gel  

International Nuclear Information System (INIS)

Synthesis of Eu-doped #beta#- and 15R-SiAlONs was studied by the ammonia nitridation of precursors derived from an #alpha#-Si_3N_4 fine powder dispersed in aluminum glycine gel with various Si/Al ratio and post-annealing in a nitrogen pressure furnace. The largest amount of #beta#-SiAlON was observed in the product at 1750 deg. C for Si/Al = 1/1 with small amounts of both #alpha#- and 15R-SiAlON impurities. The product showed two emissions at around 420 nm and 560 nm. The emission intensities decreased with increasing amount of #beta#-SiAlON. The former and latter emissions were assigned to Eu"2"+ in the 15R- and #alpha#-SiAlONs impurities. A mixture of Eu-doped 15R-SiAlON with #alpha#-Al_2O_3 impurity was obtained for Si/Al = 1/6, using AlN together with Al(NO_3)_3.9H_2O in a 2/1 atomic ratio as the aluminum source. It showed a bluish-white emission at 450 nm under 254 nm radiation.

2009-11-13

351

PCDD/F and "Dioxin-like" PCB emissions from iron ore sintering plants in the UK  

British Library Electronic Table of Contents (United Kingdom)

Investigations have been carried out at the three Corus UK sinter plants over the period 2002-2004 to characterise the emissions of both 2,3,7,8-PCDD/Fs and WHO-12 PCBs, to estimate annual mass releases of these organic micro-pollutants using the I-TEF and WHO-TEF schemes, and to investigate the formation of PCBs in the iron ore sintering process. Results showed that the sintering of iron ore produces a characteristic WHO-12 PCB and PCDD/F congener pattern that is substantially the same for all UK sinter plants. With regard to WHO-12 PCBs, the most abundant congeners were typically PCBs 118 (6-9ngNm-3), 105 (2-4ngNm-3) and 77 (2-3ngNm-3). All other WHO-12 PCBs were also detected at concentrations around 1ngNm-3. All sinter plants investigated exhibited very similar TEQ concentrations. WHO-...

2006-01-01

352

Lytic sensitivity of Actinobacillus actinomycetemcomitans Y4 to lysozyme.  

UK PubMed Central (United Kingdom)

The ability of both human and hen egg white lysozymes to lyse Actinobacillus actinomycetemcomitans Y4 was investigated. Lysis was followed optically at 540 nm by measuring the percent reduction in turbidity...Full Text Available

1983-05-01

353

Luminescent determination of zirconium and hafnium with myricetin  

International Nuclear Information System (INIS)

Reaction of formation of 3, 5, 7, 3', 4', 5' - hexaoxiflavone - myricetin complexes with zirconium and hafnium ions has been the basis for development of luminescent method of determining these elements. Optimum conditions for complexing have been determined. For Hf they are : 8-9 HCl concentration, maximum fluorescence wave length (lambda fl.)of 520 nm, wave length of exciting light (lambda el) of 436 nm, for Zr lambda fl = 536nm, lambda el = 436 nm. Stable fluorescence establishes after 25 min. for Zr and after 15 min for Hf in the presence of 40% ethanol. Usage of various camouflage agents has permitted to attain high selectivity of the method. Possibility for determination of Zr with myricetin in the presence of a 10-time excess of Hf, Cr, Cu, 50-time excess of Mo and Ti is shown. Sensitivity of Zr determination is 2.0x10 #mu#g"-"2/ml, for Hf it is 9.0x10 #mu#g"-"3 and mineral waters.

355

Internal Functionalization and Surface Modification of Vinylsilsesquioxane Nanoparticles  

UK PubMed Central (United Kingdom)

The interior of 237 nm spherical vinylsilsesquioxane nanoparticles has been covalently modified and their surface functionalized under mild conditions to yield a novel type of hybrid silsesquioxane...Full Text Available

2009-01-01

356

Experimental research of stability of thin films on the basis of depleted uranium as reflecting coating for wavelength of 4.5 nm  

International Nuclear Information System (INIS)

In this paper, we present experimentally determined reflection factors of mirrors based on the depleted uranium and dependence of reflection factor on time of presence of samples on air.

2007-05-21

357

Dependence of Energy Thresholds on Laser Radiation Wavelength in Initiation of Heavy Metal Azides  

CERN Document Server

The behavior of silver and lead azides (scaly and threadlike crystals, and compacted powders) in initiation of explosive decomposition by laser pulsed radiation has been investigated. Initiation energy thresholds in irradiation at wavelengths of 1064 nm, 532 nm, 354.7 nm, 266 nm corresponding to four laser radiation harmonics have been measured. Samples both uncovered and covered with a transparent dielectric (a quartz plate) with the compressive force of up to 0.5GPa were initiated. In the transparent spectral region (the first and second laser harmonics) of the heavy metal azide matrix the effect of covering the sample surface with a plate on initiation energy threshold was insignificant, whereas, in the region of bandgap absorption (the fourth harmonic) strong dependence of the initiation threshold on whether the surface under irradiation is uncovered or covered. The results obtained have been ...

2010-01-01

358

Amino acid analysis at the picomole level. Application to the C-terminal sequence analysis of polypeptides.  

UK PubMed Central (United Kingdom)

Amino acids labelled with dimethylaminoazobenzenesulphonyl chloride can be separated by reversed-phase high-pressure liquid chromatography and detected in the visible region (436 nm). All 19 naturally...Full Text Available

1981-12-01

359

AlGaInP single quantum well laser diodes  

Energy Technology Data Exchange (ETDEWEB)

The properties and low pressure organometallic vapor phase epitaxy of Ga{sub x}In{sub 1{minus}x}P/(AlGa){sub 0.5}In{sub 0.5}P quantum well (QW) laser diode heterostructures with Al{sub 0.5}In{sub 0.5}P cladding layers, and having wavelength 614 < {lambda} < 690 nm, are described. At longer wavelengths ({lambda} > 660 nm), threshold current densities under 200 A/cm{sup 2} and efficiencies greater than 75% result from a biaxially-compressed GaInP QW active region. Although short wavelength laser performance is diminished by the poor electron confinement afforded by AlGaInP heterostructures, good 630 nm band performance, and extension into the 610 nm band, is achieved with strained, single QW active regions.

1994-12-31

360

A Combination of Dual-mode 2,940 nm Er:YAG Laser Ablation with Surgical Excision for Treating Medium-sized Congenital Melanocytic Nevus  

UK PubMed Central (United Kingdom)

BackgroundThere are various treatment options for congenital melanocytic nevus (CMN), including surgical excision, dermabrasions, curettage, laser treatment, chemical peels and cryosurgery....Full Text Available

2009-05-01

361

Yttrium Calcium Oxyborate for high average power frequency doubling and OPCPA  

Science.gov (United States)

Significant progress has been achieved recently in the growth of Yttrium Calcium Oxyborate (YCOB) crystals. Boules have been grown capable of producing large aperture nonlinear crystal plates suitable for high average power frequency conversion or optical parametric chirped pulse amplification (OPCPA). With a large aperture (5.5 cm x 8.5 cm) YCOB crystal we have demonstrated a record 227 W of 523.5nm light (22.7 J/pulse, 10 Hz, 14 ns). We have also demonstrated the applicability of YCOB for 1053 nm OPCPA.

2006-06-20

362

Synthesis and scintillation properties of GdCl_3:Ce"3"+ (Gd_1_-_xCe_xCl_3_,x = 0.005-0.08)  

International Nuclear Information System (INIS)

Single crystals of GdCl_3 doped with different concentrations of Ce"3"+ have been grown using the Bridgman-Stockbarger technique and their luminescence and scintillation properties were investigated. The luminescence spectrum of GdCl_3:Ce"3"+ is complex and consists of two bands with maxima at 350 nm and 370 nm. The maximal light yield in GdCl_3:Ce"3"+ was observed at #approx#1 mol% of Ce"3"+ (more than 38 000 ph/MeV).

2009-07-08

363

Programmed Assembly of Quantum-Dot Arrays on DNA Templates: Hardware for Quantum Computing?  

Energy Technology Data Exchange (ETDEWEB)

This paper reports progress in the fabrication and characterization of an array of 1nm-scale colloidal particles (i.e., quantum-dot array) that can be operated to execute nontrivial and innovative computations, possibly including quantum logic. We discuss the actual fabrication of 2-nm metal clusters as an example of possible quantum dot implementation. Innovative and unconventional paradigms underlie the different stages of this work. For example, regular array geometry is achieved by directing appropriately derivatized metal clusters to preselected locations along a stretched strand of an engineered DNA sequence.

2001-03-23

364

Preparation of silver nanofluid by the submerged arc nanoparticle synthesis system (SANSS)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is fabrication and characterization of silver nanofluid by the submerged arc nanoparticle synthesis system (SANSS). The silver metal electrodes under the electrical discharge will melt and evaporate rapidly and condense to form the nanoparticles in the lower temperature dielectric liquid and produce the suspended nanoparticle. The results showed that the spherical nanosilver particle formed in the ethylene glycol and the mean particle size is about 12.5 nm. The prepared silver nanofluid was irradiated under the 410 nm visible light, electrons could be excited from the valence band to the conduction band. The silver nanofluid more closely resembles Newtonian fluids.

2007-05-31

365

Manifestation of isotope effects in absorption spectra of "1"4"4Sm"3"+ and "1"5"4Sm"3"+ in solutions  

International Nuclear Information System (INIS)

Photoluminescence spectra for solutions containing Sm"3"+ isotope ions in heavy and normal water were studied in the wave length #lambda# = 500-700 nm and for absorption spectra and photoluminescence excitation spectra within the range of #lambda# = 260-600 nm. Differences in molar extinction coefficients for "1"4"4Sm"3"+ and "1"5"4Sm"3"+ were established both in the solutions with D_2O and by transition from the solutions with D_2O to the solutions with H_2O. New possible causes of the identified effects are discussed

1998-01-01

366

Ion Transport Measurements in a Multi-Dipole Argon Plasma by Broadband Laser Induced Fluorescence  

International Nuclear Information System (INIS)

Argon ion laser induced fluorescence measurements were carried out in a multipolar filament discharge with a broadband diode laser centered on 668 nm, which stimulated a transition from the metastable state in Ar(II) 3d4F7/2 to 4p4D05/2. The intensity of the induced fluorescence at 442 nm was maximized by the optimization of the discharge parameters and the laser power. From the recovery of the background fluorescence after the laser was turned off, the ion diffusion coefficient was deduced and compared with the result inferred from the experiments of ion acoustic wave (IAW) damping.

2009-06-01

367

Inhomogeneity of electron density in amorphous films  

International Nuclear Information System (INIS)

By the methods of small-angle X-ray scattering and translucent electron microscopy the existence of inhomogeneity of electron density in hydrogenated films of amorphous silicon is confirmed. The decreased density regions are extended and form a branched network of channels oriented mostly by the normal direction to the films surface. The typical size of the decreased density regions network constitutes 10 nm in the 100-800 nm films thickness range. The increase of hydrogen total partial pressure in gas mixture in case of films growth results at first in the decrease of extension of these regions and than to micropores generation in the network nodal points of the decreased electron density regions.

368

Infrared stimulated luminescence in quartz  

Energy Technology Data Exchange (ETDEWEB)

Infrared (IR, 880 nm) stimulated luminescence (IRSL) signal was observed from quartz at room temperature. The characteristics of the signal such as its response to {gamma}-ray irradiation, thermal stability and thermal assistance energy show that the signal originates from different traps than those responsible for the luminescence signal stimulated by green light (GL, 514 nm). The IRSL signal's short lifetime (18 days at 15 deg. C) may have been the reason why it was not detected in previous experiments. The decay of the IR signal after GL illumination was observed. The thermoluminescence at 76 deg. C was enhanced after IR illumination.

2005-02-01

369

High-power continuous wave 690 nm AlGaInP laser-diode arrays  

Energy Technology Data Exchange (ETDEWEB)

High-power diode laser arrays emitting at 690 nm have been developed for solid-state laser pumping. The laser diode bars (fill factor [approx]0.7) have been fabricated from single quantum well AlGaInP-based heterostructures. Using silicon microchannel heatsinks, a record high 360 W/cm[sup 2] per emitting aperture is achieved under continuous wave operation.

1995-03-06

370

High-power CW operation of AlGaInP laser-diode array at 640 nm  

Science.gov (United States)

Visible-emitting high-power laser bars are investigated at an emission wavelength of 640 nm. AlGaInP/GaInP, single tensile-strained quantum well, separate confinement heterostructures are fabricated into one cm long laser bars using a 0.7 fill factor. The low threshold current of the diode, combined with the aggressive heatsinking of a silicon microchannel cooler has resulted in more than 12 W of continuous wave output power.

1995-02-01

371

Endomicroscopy imaging of epithelial structures using tissue autofluorescence  

Science.gov (United States)

We explore autofluorescence endomicroscopy as a potential tool for real-time visualization of epithelial tissue microstructure and organization in a clinical setting. The design parameters are explored using two experimental systems--an Olympus Medical Systems Corp. stand-alone clinical prototype probe, and a custom built bench-top rigid fiber conduit prototype. Both systems entail ultraviolet excitation at 266 nm and/or 325 nm using compact laser sources. Preliminary results using ex vivo animal and human tissue specimens suggest that this technology can be translated toward in vivo application to address the need for real-time histology.

2011-04-01

372

Electrical properties of airborne nanoparticles produced by a commercial spark-discharge generator  

International Nuclear Information System (INIS)

A nanoparticle generator based on the principle of electrical discharge (PALAS GFG-1000) was used to produce nanoparticles of different chemical natures. The fractions of electrically neutral particles were then measured by means of a Spectrometre de Mobilite Electrique Circulaire (SMEC, i.e. radial-flow mobility analyzer) for different operating conditions. The experimental results were compared with the theoretical values calculated from the Fuchs extended charge equilibrium model for spherical particles and agglomerates. For the smallest particles (below 20 nm), the deviations observed remain below 10%, and tend towards 20% for larger particles (over 35 nm).

2010-08-01

373

EXAFS Study of Semimetal-Semiconductor Transition of Bismuth Clusters  

International Nuclear Information System (INIS)

Extended X-ray absorption fine structure (EXAFS) measurements of bismuth clusters in the temperature range of 23 -300 K have been performed using synchrotron radiation in order to investigate the size dependent phase transition. The inter-atomic distances around 3.0 A and 3.6 A are attributed to the nearest neighbors within the layer and between layers, respectively. EXAFS functions were analysed by the curve fitting method within a symmetric distribution approximation. The nearest neighbor distance of the 0.5 nm thick films is shorter than that of the 300 nm thick films at all the temperatures, which is related to the reduction of the inter-layer correlation.

2007-02-02

374

Continuous wave operation (77 K) of yellow (583. 6 nm) emitting AlGaInP double heterostructure laser diodes  

Science.gov (United States)

Continuous wave lasing operation with the shortest wavelength for semiconductor lasers was obtained from AlGaInP double heterostructure lasers at 77 K. The structure was grown by metalorganic vapor phase epitaxy. Lasing wavelength was 583.6 nm (yellow). Threshold current was 43 mA (1.9 kA/cm/sup 2/). Magnesium was adopted as a p-type dopant, and was proved to be preferable for a high aluminum composition AlGaInP cladding layer.

1986-03-03

375

Bend loss for channel plasmon polaritons  

Science.gov (United States)

Using near-field optical microscopy, the authors investigate propagation of channel plasmon polaritons excited in the wavelength range of 1425-1640 nm along smoothly bent and split V-shaped grooves milled in a gold film. We find that for 0.6-?m-wide and 1.1-?m-deep grooves bent with the smallest curvature radius of ?0.83 ?m, the double bend (for S bends) and splitting (for Y splitters) losses decrease for longer wavelengths approaching (in the wavelength range of 1600-1640 nm) the levels of ~0 and 0.5 dB, respectively.

2006-10-01

376

Aluminium, gallium and indium complexing with methylthymol blue  

International Nuclear Information System (INIS)

Al, Ga and In complexing with methylthymol blue (H_6R) purified by gel filtration is studied. in the case of metal excess complexes with the ratio of components M:H_6R=2:1 with #lambda#=587(Al), 590(Ga) and 593 nm(In) appear. In the case of reacting agent excess complexes with the ratio of component 1:1 with #lambda#_m_a_x=480-490 (Al) and 480 nm(Ga, In) appear. The mechanism of complexing reactions is studied. Molar extinction coefficients and stability constants are calculated.

1988-01-01

377

5 GHz 200 Mbit/s radio over polymer fibre link with envelope detection at 650 nm wavelength  

DEFF Research Database (Denmark)

All-optical envelope detection of a 5 GHz 200 Mbit/s modulated radio frequency signal is achieved using a 650 nm resonant cavity light emitting diode. Error-free transmission is achieved over a 50 m-long link of 1 mm diameter graded index polymer optical fibre (POF). The presented system has potential applications in low cost and low complexity short range wireless and wireline POF-based transmission links.

2008-01-01

378

Radioisotope production in the I.Ph.P.E. cyclotron for medical application  

International Nuclear Information System (INIS)

The production methods for seven radioisotopes, Ga-67, Sr-85, Pd-103, In-111, Tu-167, Hg-197 and Pb-203, by using a classical 1.5m cyclotron in the Institute of Physics and Power Engineering, Obninsk, USSR, are described. At present, more than 50 cyclotrons in different countries are used for the production of radioisotopes applied to medicine. Radioisotopes are produced with the cyclotron in the I.Ph.P.E. in the form of irradiated targets, which are delivered to Moscow radiopharmaceutical factory, where radiopharmaceuticals are produced on the base of these targets. The cyclotron is operated in two regimes providing the acceleration of protons, deuterons and alpha -particles. Two types of target assemblies are used for irradiation, the one is intended for the internal beam, and the other is for the external beam. The reactions used for the production of seven radioisotopes described above, the types of ...

379

Radioisotope production in the I. Ph. P. E. cyclotron for medical application  

Energy Technology Data Exchange (ETDEWEB)

The production methods for seven radioisotopes, Ga-67, Sr-85, Pd-103, In-111, Tm-167, Hg-197 and Pb-203, by using a classical 1.5m cyclotron in the Institute of Physics and Power Engineering, Obninsk, USSR, are described. At present, more than 50 cyclotrons in different countries are used for the production of radioisotopes applied to medicine. Radioisotopes are produced with the cyclotron in the I.Ph.P.E. in the form of irradiated targets, which are delivered to Moscow radiopharmaceutical factory, where radiopharmaceuticals are produced on the base of these targets. The cyclotron is operated in two regimes providing the acceleration of protons, deuterons and alpha -particles. Two types of target assemblies are used for irradiation, the one is intended for the internal beam, and the other is for the external beam. The reactions used for the production of seven radioisotopes described above, the types of ...

1982-01-01

380

Distortion-invariant color pattern recognition using multiple phase-shifted-reference-based joint transform correlation incorporating synthetic discriminant function  

Science.gov (United States)

This paper proposes a new pattern recognition system employing optical joint transform correlation (JTC) technique which offers a great number of advantages over similar digital techniques, including very fast operation, simple architecture and capability of updating the reference image in real time. The proposed JTC technique incorporates a synthetic discriminant function (SDF) of the target image estimated from different training images to make the pattern recognition performance invariant to noise and distortion. It then involves four different phase-shifted versions of the same target SDF reference image, which are individually joint transform correlated with the given input scene. When the correlation signals are combined, it produces a single cross-correlation peak corresponding to each potential target present in the given input scene. The proposed technique also includes a fringe-adjusted filter to generate a ...

2011-04-01

381

Uses of laser optical pumping to produce polarized ion beams  

Energy Technology Data Exchange (ETDEWEB)

Laser optical pumping can be used to produce polarized alkali atom beams or polarized alkali vapor targets. Polarized alkali atom beams can be converted into polarized alkali ion beams, and polarized alkali vapor targets can be used to produce polarized H/sup -/ or /sup 3/He/sup -/ ion beams. In this paper the authors discuss how the polarized alkali atom beams and polarized alkali vapor targets are used to produce polarized ion beams with emphasis on the production of polarized negative ion beams.

1983-04-01

382

The HARP experiment first physics results  

CERN Document Server

The HARP experiment at CERN is performing extensive measurements of hadron production cross sections and secondary particle yields, in the momentum range 1.5-15 GeV/c, over the full solid angle and using a large set of cryogenic and solid targets. First measurements of hadron production cross-sections in the forward region are reported using an aluminium target 5% of an interaction length thick and a proton beam of 12.9 GeV/c. A preliminary analysis in the large angle region of elastic scattering events produced with the cryogenic hydrogen target at 3 GeV/c beam momentum is also presented.

2005-01-01

383

Separation of carrier-free "1"7"6","1"7"7W and "1"7"6","1"7"7Ta produced in "1"6O irradiated holmium target  

International Nuclear Information System (INIS)

Carrier-free radionuclides of tungsten and tantalum, "1"7"6","1"7"7W and "1"7"6","1"7"7Ta have been produced by heavy ion activation of holmium target with 97 MeV "1"6O"5"+ beam. Radiochemical separation scheme has been developed to isolate tungsten and tantalum radionuclides from the holmium target matrix. (author)

2001-11-01

384

Separation of carrier free "1"7"6","1"7"7W and "1"7"6","1"7"7Ta radionuclides produced in "1"6O activated holmium metal target  

International Nuclear Information System (INIS)

Carrier-free radioisotopes of tungsten, "1"7"6","1"7"7W, and their corresponding daughter radionuclides "1"7"6","1"7"7Ta, have been produced in holmium target by heavy ion activation with "1"6O"5"+ beam. An attempt has been made to separate these carrier-free radionuclides from bulk holmium target through LLX using cation exchanger HDEHP. (author)

2001-02-07

385

Recovery of radioactive thallium isotopes from lead and bismuth targets irradiated by 1-GeV protons  

Energy Technology Data Exchange (ETDEWEB)

A simple highly efficient procedure has been developed for recovery of thallium radioisotopes from lead and bismuth targets irradiated by 1-GeV protons. The procedure is based on the use of extraction chromatography. The cross-sections have been determined for formation of {sup 200}Pb, {sup 201}Pb, {sup 202m}Pb, and {sup 203}Pb radioisotopes in targets from lead with natural isotopic composition, irradiated by 1-GeV protons.

1995-03-01

386

Recovery of radioactive thallium isotopes from lead and bismuth targets irradiated by 1-GeV protons  

International Nuclear Information System (INIS)

A simple highly efficient procedure has been developed for recovery of thallium radioisotopes from lead and bismuth targets irradiated by 1-GeV protons. The procedure is based on the use of extraction chromatography. The cross-sections have been determined for formation of "2"0"0Pb, "2"0"1Pb, "2"0"2"mPb, and "2"0"3Pb radioisotopes in targets from lead with natural isotopic composition, irradiated by 1-GeV protons.

387

Preliminary Study of Plasma Stream Interaction with Tungsten Target within RPI-IBIS Facility  

International Nuclear Information System (INIS)

The paper presents results of experimental research on the interaction of a pulsed plasma-ion stream with a tungsten (W) target. The pulsed hydrogen plasma was produced within the RPI-IBIS (Multi-Rod Plasma Injector) facility at IPJ in Swierk. Measurements were carried out by means of optical spectroscopy and corpuscular diagnostic techniques. For experiments with the W-target the operational conditions (so-called PID mode) were chosen when a clean hydrogen plasma stream was generated. Attention was paid to the identification of WI and WII spectral lines.

2006-01-01

388

Modified-VSIMM algorithm with an application to the naval fire control technology  

British Library Electronic Table of Contents (United Kingdom)

A modified variable structure interacting multiple model (M-VSIMM) estimator for complex hybrid maneuver target tracking is presented. The M-VSIMM could potentially be applied to fire control systems (FCS) used on warships. Target model groups were designed using 3D dimensional dynamic target models. Optimal model group selection logic was proposed, contrary to the activation and termination logic in the original VSIMM. The system will respond faster with optimal model group selection logic. After performing simulations, the tracking performances of the Kalman, ?-?(-?), VDIE, IMM and M-VSIMM filters were compared under various maneuvering conditions.

2011-01-01

389

Experiments to investigate the effects of radiative cooling on plasma jet collimation  

CERN Document Server

Preliminary experiments have been performed to investigate the effects of radiative cooling on plasma jets. Thin (3 um - 5 um) conical shells were irradiated with an intense laser, driving jets with velocities > 100 km/s. Through use of different target materials - aluminium, copper and gold - the degree of radiative losses was altered, and their importance for jet collimation investigated. A number of temporally resoved optical diagnostics was used, providing information about the jet evolution. Gold jets were seen to be narrower than those from copper targets, while aluminium targets produced the least collimated flows.

2010-01-01

390

Convoy electron production in polycrystalline and monocrystalline targets  

Energy Technology Data Exchange (ETDEWEB)

The velocity distribution of electrons ejected close to the forward direction by 0.8-2 MeV/A ions traversing various solid targets, including a Au monocrystal, is measured in coincidence with emerging charge-selected ions. The velocity spectrum is observed to be independent of outgoing projectile velocity and charge state for polycrystalline targets. Measurements on the Au crystal under channeling conditions show dependences on final charge state, and are tentatively explained by assuming that the main contribution to the production yield comes from the non-channeled fraction of the ions. A simple model for the creation of the forward-ejected electrons is proposed, which accounts for most of the experimental findings.

1980-01-01

391

Computer-assisted rotation and multiple stationary irradiation technique  

International Nuclear Information System (INIS)

A computer-assisted rotation and stationary conformation radiotherapy system with overrunning multileaf collimators has been developed. This system can produce any shape of target volume, including a number of target areas outside the axis of the rotation, regardless of the location of the axis at 360"0 rotation irradiation. In addition, by changing the dose rate and deleting a partial region within a field, multiple stationary irradiation can produce more homogeneous target volumes - thus avoiding excessive irradiation to critical organs - than the rotation technique. (orig.).

392

Centroid and Envelope Dynamics of High-intensity Charged Particle Beams in an External Focusing Lattice and Oscillating Wobbler  

Energy Technology Data Exchange (ETDEWEB)

The centroid and envelope dynamics of a high-intensity charged particle beam are investigated as a beam smoothing technique to achieve uniform illumination over a suitably chosen region of the target for applications to ion-beam-driven high energy density physics and heavy ion fusion. The motion of the beam centroid projected onto the target follows a smooth pattern to achieve the desired illumination, for improved stability properties during the beam-target interaction. The centroid dynamics is controlled by an oscillating "wobbler", a set of electrically-biased plates driven by RF voltage. __________________________________________________

2010-04-28

393

The Development of Meteorological Data Fields for the Radiological Emergency Preparedness  

Energy Technology Data Exchange (ETDEWEB)

In this study we tried to develop the long-range transport system and find the way to prevent from the radiological emergency risk. For the study, meteorological forecast system in Korea Meteorological Administration is investigated. Numerical simulation is also carried out by the long-range transport model and Vis-5D. We surveyed the emergency preparedness for nuclear accidents which were ARAC in USA, RODOS in Europe and WSPEED in Japan and then investigated the processing of medium- and long-range atmospheric diffusion modeling system. We also studied on the application of KMA/NWPD model which are GDAPS and RDAPS. In the future, it is necessary to produce to the high resolution meteorological data from KMA/NWPD for the development of medium- and long-range atmospheric diffusion modeling system and construct the integrated system for data processing in real time. It was simulated by using micro-scale meteorological field applying wind field model with high ...

2000-04-01

394

Yields of Residual Nuclei from Proton-Irradiated Materials  

International Science & Technology Center (ISTC)

Experimental and Theoretical Study of the Residual Nuclide Production in 40-2600 MeV Proton-Irradiated Thin Targets of ADS Basic Materials

395

Tuberculous Granulomas Are Hypoxic in Guinea Pigs, Rabbits, and Nonhuman Primates?  

UK PubMed Central (United Kingdom)

Understanding the physical characteristics of the local microenvironment in which Mycobacterium tuberculosis resides is an important goal that may allow the targeting of metabolic processes...Full Text Available

2008-06-01

397

The influence of target backing on ion-beam electron spectra  

International Nuclear Information System (INIS)

Several different aspects of the influence of the target backing on in-beam electron spectra following compound nuclear reactions induced by accelerated ions at tandem energies irradiating backed targets are discussed in detail. This discussion is illustrated by a few typical examples, such as "1"2C"5"+ and "3"1P"1"0"+ beams at 4 MeV/u bombarding Sn(+Be), Sn(+Au), Pb(+C) backed targets. Moreover, the relative influence of electron backscattering, electron Doppler shift and Doppler broadening as well as #delta#-electron emission on the low energy electron spectra (E_e#<=#100 keV) obtained under such conditions are investigated in the frame of the available experimental data. (orig.).

398

The importance of an accurate target wave function in variational calculations for (e^{+}-H_{2}) scattering  

CERN Document Server

Using the complex Kohn method, we have calculated variational values of phase shifts and the annihilation parameter, Z_{eff}, for the elastic scattering of positrons by molecular hydrogen. Our results are sensitive to small changes in the accuracy of the wave function representing the target hydrogen molecule. We have developed a systematic approach to demonstrate that, at low positron energies, there are particular forms of the Kohn trial wave function for which the results of variational calculations are not reliable, even when the target wave function accounts for as much as 96.8% of the correlation energy of H_{2}. We find that reliable results can be recovered if our calculations are extended to admit more sophisticated target wave functions accounting for 99.7% of the correlation energy. Remaining discrepancies between theory and experiment are briefly discussed.

2008-01-01

399

The Growth Cone Cytoskeleton in Axon Outgrowth and Guidance  

UK PubMed Central (United Kingdom)

Axon outgrowth and guidance to the proper target requires the coordination of filamentous (F)-actin and microtubules (MTs), the dynamic cytoskeletal polymers that promote shape change and locomotion....Full Text Available

400

The Development of New Methods for Solving the Target ...  

Science.gov (United States)

... and 7 survey papers. On the inverse Stefan problem he wrote 3 research papers and 1 survey paper. The papers on inverse ...

1984-07-18

401

Target space duality I: general theory  

Energy Technology Data Exchange (ETDEWEB)

We develop a systematic framework for studying target space duality at the classical level. We show that target space duality between manifolds M and M-tilde arises because of the existence of a very special symplectic manifold. This manifold locally looks like MxM-tilde and admits a double fibration. We analyze the local geometric requirements necessary for target space duality and prove that both manifolds must admit flat orthogonal connections. We show how abelian duality, nonabelian duality and Poisson-Lie duality are all special cases of a more general framework. As an example we exhibit new (nonlinear) dualities in the case M=M-tilde=R{sup n}.

2000-09-25

402

Studies of relativistic heavy ion collisions at the AGS (Experiment 814)  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the experimental setup of experiment 814 at Brookhaven AGS. This experiment involves the collision of silicon ions with target nuclei. The detector systems are discussed primarily. (LSP)

1990-01-01

403

Smoking and reproduction: The oviduct as a target of cigarette smoke  

UK PubMed Central (United Kingdom)

The oviduct is an exquisitely designed organ that functions in picking-up ovulated oocytes, transporting gametes in opposite directions to the site of fertilization, providing a suitable environment...Full Text Available

404

Principles of antibody therapy.  

UK PubMed Central (United Kingdom)

The success of monoclonal antibodies in clinical practice is dependent on good design. Finding a suitable target is the most important part as other properties of the antibody can be altered by genetic...Full Text Available

1992-12-05

405

Novel Cytotoxic Vectors Based on Adeno-Associated Virus  

Wastenet

positive primary PymT breast cancer cells in primary co-cultured tumor tissue, suggesting target specificity of

406

Measured Temperatures of Solid Rocket Motors Dump Stored ...  

Science.gov (United States)

... TARGET SENSOR-MK 80 SERIES BOMBS ... 5-inch-, and 2.75-inch- diameter rocket motors that ... balance when compared to incoming solar radiation ...

1989-07-01

407

Knowledge-Based Identification of the ERK2/STAT3 Signal Pathway as a Therapeutic Target for Type 2 Diabetes and Drug Discovery  

British Library Electronic Table of Contents (United Kingdom)

Many existing agents for diabetes therapy are unable to restore or maintain normal glucose homeostasis or prevent the eventual emergence of hyperglycemia-related complication. Therefore, agents based on novel mechanisms are sought to complement and extend the current therapeutic approaches. Based on the initial paper research, we focused on active STAT3 as an attractive pharmacological target for type 2 diabetes. The subsequent text mining with a unique query to identify suppressors but not activators of STAT3 revealed the ERK2/STAT3 pathway as a novel diabetes target. The description of ERK2 inhibitors as diabetes target had not been found in our text mining research at present. The mechanism-based peptide inhibitor for ERK2 was identified using the knowledge of the KIM sequence, which ha...

2011-01-01

408

Johnson News - NASA  

Science.gov (United States)

Nov 21, 2003... for the European Space Agency's Automated Transport Vehicle, a new, uncrewed station cargo vehicle targeted for launch late next year. ...

409

Ion channels, transporters, and pumps as targets for heart failure  

UK PubMed Central (United Kingdom)

Congestive heart failure (CHF) is a leading cause of morbidity and mortality. CHF is marked by atrial and ventricular enlargement and reduced cardiac contractility, as well as an association...Full Text Available

2009-10-01

410

Imaging immune response in vivo  

UK PubMed Central (United Kingdom)

PurposeClinical trials have commenced to evaluate the feasibility of targeting malignant gliomas with genetically engineered cytolytic T-cells (CTLs) delivered directly...Full Text Available

2008-06-15

411

Heat shock proteins as emerging therapeutic targets  

UK PubMed Central (United Kingdom)

Chaperones (stress proteins) are essential proteins to help the formation and maintenance of the proper conformation of other proteins and to promote cell survival after a large variety of environmental...Full Text Available

2005-11-01

412

Genomics of human longevity  

UK PubMed Central (United Kingdom)

In animal models, single-gene mutations in genes involved in insulin/IGF and target of rapamycin signalling pathways extend lifespan to a considerable extent. The genetic, genomic and epigenetic influences...Full Text Available

2011-01-12

413

Gene therapy for ocular diseases  

UK PubMed Central (United Kingdom)

The eye is an easily accessible, highly compartmentalised and immune-privileged organ that offers unique advantages as a gene therapy target. Significant advancements have been made in understanding...Full Text Available

2011-05-01

414

GAVA: Spectral Simulation for In Vivo MRS Applications  

UK PubMed Central (United Kingdom)

An application that provides a flexible and easy to use interface to the GAMMA spectral simulation package is described that is targeted at investigations using in vivo MR spectroscopic methods....Full Text Available

2007-04-01

415

Evaluation of phenylpiperazines as targeting agents for neuroblastoma.  

UK PubMed Central (United Kingdom)

The potential of radiolabelled phenylpiperazines as agents for the detection and therapy of tumours of neural crest origin was evaluated by in vitro pharmacological studies with human neuroblastoma...Full Text Available

1996-09-01

416

Effects of voicing in the recognition of concurrent syllables (L)a)  

UK PubMed Central (United Kingdom)

This letter reports a study designed to measure the benefits of voicing in the recognition of concurrent syllables. The target and distracter syllables were either voiced or whispered, producing...Full Text Available

2009-12-01

417

Dynamic clamp with StdpC software  

UK PubMed Central (United Kingdom)

Dynamic clamp is a powerful method that allows the introduction of artificial electrical components into target cells to simulate ionic conductances and synaptic inputs. This method is based...Full Text Available

2011-03-01

418

Dynamic Weapon-Target Assignment Problems with ...  

Science.gov (United States)

... defense's weapons are Space-based kinetic-kill vehicles ... I ti I obtained by dividing the weapons as ... of the optimal weapon-arge assigntments and ...

1988-06-01

419

Cooperative Charging Effects of Fibers From Electrospinning ...  

Science.gov (United States)

... In the Proceedings of INTC 2003, we studied charging effects on target coverage during electrospinning (16). ... of Fibers from Electrospinning of ...

2005-01-05

420

Comparative genomics of insect juvenile hormone biosynthesis?  

UK PubMed Central (United Kingdom)

The biosynthesis of insect juvenile hormone (JH) and its neuroendocrine control are attractive targets for chemical control of insect pests and vectors of disease. To facilitate the molecular...Full Text Available

2006-04-01

421

Cholinergic modulation of multivesicular release regulates striatal synaptic potency and integration  

UK PubMed Central (United Kingdom)

The pleiotropic actions of neuromodulators on pre- and postsynaptic targets present challenges to disentangling the mechanisms underlying regulation of synaptic transmission. Within the striatum,...Full Text Available

2009-09-01

422

Bacterial flora-typing with targeted, chip-based Pyrosequencing  

UK PubMed Central (United Kingdom)

BackgroundThe metagenomic analysis of microbial communities holds the potential to improve our understanding of the role of microbes in clinical conditions. Recent, dramatic improvements...Full Text Available

423

Approaches to the evaluation of chemical-induced immunotoxicity.  

UK PubMed Central (United Kingdom)

The immune system plays a crucial role in maintaining health; however, accumulating evidence indicates that this system can be the target for immunotoxic effects caused by a variety of chemicals including...Full Text Available

1995-12-01

424

An Extended Kalman Filter for Use in a Shared Aperture ...  

Science.gov (United States)

... used to track a point source target ... A one sigma tracking error of .2 ... LOOKING INFRARED SYSTEMS, *KALMAN FILTERING, SIGNAL PROCESSING ...

1978-12-01

425

A comprehensive assessment of N-terminal signal peptides prediction methods  

UK PubMed Central (United Kingdom)

BackgroundAmino-terminal signal peptides (SPs) are short regions that guide the targeting of secretory proteins to the correct subcellular compartments in the cell. They are cleaved...Full Text Available

426

Very high resolution measurements of the total cross section of natural iron  

Energy Technology Data Exchange (ETDEWEB)

The total cross section of natural Fe has been measured with the GELINA pulsed white neutron source with a time-of-flight resolution of about 3.8 ps/m and good statistical precision. Measurements have been performed on three sample thicknesses including one with an average transmission of 0.1, in order to check for consistency and for remaining resolution effects. The cross sections in the {open_quotes}unresolved resonance region{close_quotes} still show rather strong fluctuations. These data will directly be used in shielding benchmark calculations. The resonance region data will be analysed by an R-matrix routine and the parameters be compared to existing compilations.

1994-12-31

427

The potential of multidiurnal MODIS thermal band data for coal fire detection  

British Library Electronic Table of Contents (United Kingdom)

In this paper we present the results of our analyses of multidiurnal low-resolution Moderate Resolution Imaging Spectroradiometer (MODIS) thermal data for coal fire-related thermal anomaly detection. Results are presented for data of the Jharia coal mining region of India. We combine three relatively new approaches: first, we use low-resolution MODIS data for coal fire area analyses, which has only been undertaken by a few authors. Second, we analyse data from four different times of day (morning, afternoon, evening and predawn) and for three different bands (MODIS bands 20, 32 and a ratio thereof); and third, we use an unbiased automated algorithm for thermal anomaly extraction of local thermal anomalies. The MODIS data analysed stem from the years 2001 and 2005. In 2001, MODIS data were ...

2008-01-01

428

Segmented focal plane detector for light and heavy ions  

Energy Technology Data Exchange (ETDEWEB)

A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).

1992-06-15

429

Quadrant anode image sensor  

Science.gov (United States)

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 ..mu.., allows individual MCP channels to be distinguished. (AIP)

1976-11-01

430

Quadrant anode image sensor  

International Nuclear Information System (INIS)

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 #mu#, allows individual MCP channels to be distinguished.

9472-01-01

431

PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.  

Energy Technology Data Exchange (ETDEWEB)

We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the size and number of Te inclusions within ...

2006-10-29

432

Isomorphisms of quantizations via quantization of resolutions  

CERN Document Server

In this paper we prove the existence of isomorphisms between certain non-commutative algebras that are interesting from representation theoretic perspective and arise as quantizations of certain Poisson algebras. We show that quantizations of Kleinian resolutions obtained by three different constructions are isomorphic to each other. The constructions are via symplectic reflection algebras, quantum Hamiltonian reduction, and W-algebras. Next, we prove that parabolic W-algebras in type A are isomorphic to quantum Hamiltonian reductions associated to quivers of type A. Finally, we show that the symplectic reflection algebras for wreath-products of the symmetric group and a Kleinian group are isomorphic to certain quantum Hamiltonian reductions. Our results involving W-algebras are new, while for those dealing with symplectic reflection algebras we just give new proofs. A key ingredient in our proofs is the study of quantizations of symplectic ...

2010-01-01

433

High-resolution sequence stratigraphy and its controls on uranium mineralization. Taking middle Jurassic Qingtujing formation in Chaoshui basin as an example  

International Nuclear Information System (INIS)

By applying the high-resolution sequence stratigraphy, the different sub-divisions of base-level cycles of Qingtujing Formation, Middle Jurassic in Chaoshui Basin are analyzed in detail. 23 short, 3 middle and 1 long base-level cycles are recognized. On the above basis, the corresponding frameworks of high-resolution sequence stratigraphy have been established in northern and southern sub-basins respectively, and the detailed sedimentary facies of MSC_1_-_3 and the special distribution of Qintujing Formation are discussed. It is pointed out that MSC_2 is the most favorable layer for the localization of sandstone-type uranium deposits. (authors)

2006-06-01

434

High-resolution NMR on /sup 29/Si nuclei in acidic zeolites  

Science.gov (United States)

The effect of treatment of Na-forms of zeolites with HCl solutions and of heat treatment of their NH/sub 4/-forms on the stability of aluminum-oxygen tetrahedra has been studied in this work by high-resolution NMR on /sup 29/Si nuclei, using the synthetic zeolites X, Y, and M (mordenite) as the objects of the study. The exchange capacity with respect to Na/sup +/ ions was determined by analyzing the equilibrium solutions after contact of the samples with 0.5 NH/sub 4/Cl solution on a flame photometer. The high-resolution /sup 29/Si NMR spectra of polycrystalline samples were recorded on an SKhR-200 spectrometer with a superconducting solenoid at a frequency of 39.75 MHz with ultrafast mechanical rotation (3 kHz) of the sample at the magic angle to the external magnetic field. The results obtained are given.

1986-12-01

435

High speed inverted optical-resolution photoacoustic microscopy  

Science.gov (United States)

Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional raster scans of 100 by 50 points. The corresponding twodimensional B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23+/-0.03 ?m for Au nano-wire imaging, which is 2.0 times below the diffraction limit.

2011-02-01

436

Development of a new #gamma#-ray detector for PEM applications  

International Nuclear Information System (INIS)

The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)

2007-05-01

437

Automatic Extraction of Open Space Area from High Resolution Urban Satellite Imagery  

CERN Document Server

In the 21st century, Aerial and satellite images are information rich. They are also complex to analyze. For GIS systems, many features require fast and reliable extraction of open space area from high resolution satellite imagery. In this paper we will study efficient and reliable automatic extraction algorithm to find out the open space area from the high resolution urban satellite imagery. This automatic extraction algorithm uses some filters and segmentations and grouping is applying on satellite images. And the result images may use to calculate the total available open space area and the built up area. It may also use to compare the difference between present and past open space area using historical urban satellite images of that same projection

2011-01-01

438

Analysis of Ground Deformation Detected Using the SBAS-DInSAR Technique in Umbria, Central Italy  

British Library Electronic Table of Contents (United Kingdom)

Ground deformation affecting the Umbria region (central Italy) in the 9-year period from 1992 to 2000 was investigated through multi-temporal Differential Synthetic Aperture Radar Interferometry (DInSAR). For the purpose, the Small BAseline Subset (SBAS) technique was adopted, which allows studying the temporal evolution of the detected deformation at two spatial scales: a low-resolution (regional) scale, and a full-resolution (local) scale. For the analysis, SAR data acquired by the European Remote Sensing (ERS-1/2) satellites along ascending and descending orbits were used. The detected deformation was analysed to investigate its relevance to geophysical, geomorphologic, and human-induced processes that may result in hazardous conditions to the population of Umbria. Low-resolution deform...

2009-01-01

439

Reflectance, Optical Properties, and Stability of Molybdenum/Strontium and Molybdenum/Yttrium Multilayer Mirrors  

Energy Technology Data Exchange (ETDEWEB)

The motivation of this work is to develop high reflectance normal-incidence multilayer mirrors in the 8-12 nm wavelength region for applications in astronomy and extreme ultraviolet lithography. To achieve this goal, Mo/Sr and Mo/Y multilayers were studied. These multilayers were deposited with a UHV magnetron sputtering system and their reflectances were measured with synchrotron radiation. High normal-incidence reflectances of 23% at 8.8 nm, 40.8% at 9.4 nm, and 48.3% at 10.5 nm were achieved. However, the reflectance of Mo/Sr multilayers decreased rapidly after exposure to air. Attempts to use thin layers of carbon to passivate the surface of Mo/Sr multilayers were unsuccessful. Experimental results on the refractive index {tilde n} = 1-{delta} + i{beta} of yttrium and molybdenum in the 50-1300 eV energy region are reported in this work. This is the first time ever that values on the refractive index ...

2002-09-01

440

X-ray structure of sensory rhodopsin II at 2.1-? resolution  

UK PubMed Central (United Kingdom)

Sensory rhodopsins (SRs) belong to a subfamily of heptahelical transmembrane proteins containing a retinal chromophore. These photoreceptors mediate the cascade of vision in animal eyes and phototaxis...Full Text Available

2001-08-28

441

Teaching electron diffraction and imaging of macromolecules.  

UK PubMed Central (United Kingdom)

Electron microscopic analysis can be used to determine the three-dimensional structures of macromolecules at resolutions ranging between 3 and 30 A. It differs from nuclear magnetic resonance spectroscopy...Full Text Available

1993-05-01

442

Tandem repeats analysis for the high resolution phylogenetic analysis of Yersinia pestis  

UK PubMed Central (United Kingdom)

BackgroundYersinia pestis, the agent of plague, is a young and highly monomorphic species. Three biovars, each one thought to be associated with the last three Y....Full Text Available

443

THE OGIP FORMAT FOR 2-D (IMAGE) POINT SPREAD FUNCTION ... - NASA  

Science.gov (United States)

tial/angular spreading of incident photons from a point source caused by the instrument (de- .... Filter. CDTP0001= 'DATA. ' / Type of calibration. CCNM0001= '2D_PSF ' ... the final resolution of sigma=0.5 arcmin in all energy bands. ...

444

Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector  

UK PubMed Central (United Kingdom)

To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available

2011-03-01

445

Solid-state 13C NMR spectroscopy of a 13C carbonyl-labeled polypeptide  

UK PubMed Central (United Kingdom)

High resolution structural elucidation of macromolecular structure by solid-state nuclear magnetic resonance requires the preparation of uniformly aligned samples that are isotopically labeled. In...Full Text Available

1992-06-01

446

Sensitivity of psychophysical measures to signal processor modifications in cochlear implant users  

UK PubMed Central (United Kingdom)

Experienced users of the Clarion cochlear implant were tested acutely with the HiResolution (HiRes) and HiRes Fidelity120 (F120) processing strategies. Three psychophysically-based tests were...Full Text Available

2010-04-01

447

Semiconductor Radiation Detectors with Frisch Collars and Collimators for Gamma Ray Spectroscopy and Imaging  

Energy Technology Data Exchange (ETDEWEB)

To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design

2006-12-04

448

SCALER WITH RESOLUTION TIME EQUAL TO 10 NANOSECONDS  

Science.gov (United States)

In systems of fast decimal counters, there are three problems to be resolved: to study a bistable having a short switching time, to form with the aid of three bistables a circuit divisible by 5, and to normalize the input pulses. The solutions to these problems for the nonsecond scaler are presented. (J.S.R.)

1960-01-01

449

Research in heavy-ion nuclear physics  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the following topics: Fusion-fission in light nuclear systems; High-resolution Q-value measurement for the {sup 24}Mg+{sup 24}Mg reaction; Heavy-ion reactions and limits to fusion; and Hybrid MWPC-Bragg curve detector development.

1992-01-01

450

Photophysics and optical switching in green fluorescent protein mutants  

UK PubMed Central (United Kingdom)

We demonstrate by using low-temperature high-resolution spectroscopy that red-shifted mutants of green fluorescent protein are photo-interconverted among three conformations and are, therefore, not...Full Text Available

2000-03-28

451

Optical sectioning of microbial biofilms.  

UK PubMed Central (United Kingdom)

Scanning confocal laser microscopy (SCLM) was used to visualize fully hydrated microbial biofilms. The improved rejection of out-of-focus haze and the increased resolution of SCLM made it preferable...Full Text Available

1991-10-01

452

Noise bias in the refinement of structures derived from single particles  

Energy Technology Data Exchange (ETDEWEB)

One of the main goals in the determination of three-dimensional macromolecular structures from electron microscope images of individual molecules and complexes (single particles) is a sufficiently high spatial resolution, about 4 A, at which the interpretation with an atomic model becomes possible. To reach high resolution, an iterative refinement procedure using an expectation maximization algorithm is often used that leads to a more accurate alignment of the positional and orientational parameters for each particle. We show here the results of refinement algorithms that use a phase residual, a linear correlation coefficient, or a weighted correlation coefficient to align individual particles. The algorithms were applied to computer-generated data sets that contained projections from model structures, as well as noise. The algorithms show different degrees of over-fitting, especially at high resolution where the signal is ...

2004-12-15

453

Noise Susceptibility of Cochlear Implant Users: The Role of Spectral Resolution and Smearing  

UK PubMed Central (United Kingdom)

The latest-generation cochlear implant devices provide many deaf patients with good speech recognition in quiet listening conditions. However, speech recognition deteriorates rapidly as the level of...Full Text Available

2005-03-01

454

NAME=\\  

Wastenet

... Buckeye rapidly produces high resolution imagery over a commander's area of interest contributing to intelligence, surveillance and reconnaissance, and also creates detailed mapping of the battlespace. BIG uses an innovative, original and creative combination of Web programming languages, Geographic Information Systems, and ...

455

NAME=\\  

Wastenet

...because it had greatly contributed to the geospatial capability of coalition forces in the Global War on Terrorism by producing a system that provides high-resolution imagery for use in detecting ground changes, creating detailed maps and obtaining Intelligence, Surveillance and Reconnaissance (ISR) information. ...

456

NAME=\\  

Wastenet

...Quality = $290,604 to improve permit compliance and appropriate preservation of wetlands by providing a spatial dataset to locate individual wetland permits on a property using high resolution imagery within specific regions of Virginia; this data set will be compared with the permit Comprehensive Environmental Database System that is currently used ...

457

Longitudinally and circumferentially directed movements of the left ventricle studied by cardiovascular magnetic resonance phase contrast velocity mapping  

UK PubMed Central (United Kingdom)

ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available

458

Laser-assisted solar-cell metallization processing  

Energy Technology Data Exchange (ETDEWEB)

Laser assisted solar cell metallization processing which is a one step process is examined. The potential advantages of laser disposition techniques for photovoltaic systems are: a high resolution, no photolithography, clean and contamination free, in-situ sintering, and low contact resistance.

1984-03-01

459

Joint Research Centre - JRC - European Commission  

Wastenet

... The high resolution imagery , collected over Rio de Janeiro, Brazil, included a mixture of large commercial buildings and private houses, as well as the airport and some community parks. 10/08/11 Read more Top EU R&D companies expect a 5% ...

460

Ion beam pulsing for time of flight (TOF) experiments  

Energy Technology Data Exchange (ETDEWEB)

The essential mechanical and electronic parts of a beam pulsing system are described, which reaches an energy resolution of ..delta..E/E=0.1%-0.4% in the energy range from 100 eV and 10 keV.

1985-01-01

461

Inferring transcription factor complexes from ChIP-seq data  

UK PubMed Central (United Kingdom)

Chromatin immunoprecipitation followed by high-throughput sequencing (ChIP-seq) allows researchers to determine the genome-wide binding locations of individual transcription factors (TFs) at high resolution....Full Text Available

2011-08-01

462

High-resolution sequence stratigraphic character and sandstone-type uranium ore formation. A case from Saihan Formation in Baiyinwula area, Erlian Basin  

International Nuclear Information System (INIS)

High-resolution sequence stratigraphy has been applied widely in the petroleum exploration and development, many achievements have been achieved. However, it is in the beginning stage that high-resolution sequence stratigraphy is applied to explore the sandstone-type uranium deposits in Erlian Basin. By applying principles of high-resolution sequence stratigraphy and taking typical boreholes as an example, sedimentary cycles of Saihan Formation, the ore-bearing formation in Baiyinwula area are divided and correlated through cross sections. One long-term cycle (LSC_1), two middle-term cycles (MSC_1, MSC_2) have been identified in this study. Based on this and combined with the mineralization character of sandstone uranium deposits in this area, it is presented that the interlayer oxidation zone is developed mainly in the rising hemicycle of MSC_1 and uranium ore bodies predominantly in channel sand bodies that were developed ...

2006-12-01

463

High-resolution beta imaging; L'imagerie beta haute resolution  

Energy Technology Data Exchange (ETDEWEB)

For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of experiments. Real time radio-imagers ({beta}-imager and {mu}-imager) are preferred to verify experimental conditions. The {beta}--imager and s-imager are ...

2007-04-15

464

High resolution alpha-particle spectroscopy using CR-39 plastic track detector  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed for high resolution alpha particle spectroscopy from track length determination in CR-39 plastic. On individual tracks an energy resolution deltaE close to the range straggling limit is obtainable. For 6 MeV alpha-particle deltaE is proportional 35 keV on individual particles and for groups of particles deltaE proportional 20 keV can be achieved using certain data selection criteria. At 100 keV on individual particles deltaE is proportional 20 keV. The analysis requires 1) a knowledge of the track-etch rate (Vsub(T))-range relationship and 2) a theoretical understanding of alpha-particle track structure in CR-39 as a function of particle energy, dip angle and degree of etching. The structure of alpha-particle etched tracks in CR-39 is described and two methods of analysis discussed. Examples are given of the resolution attainable on tracks of alpha-particles as natural decay energy and from ...

1984-06-15

465

Gravitropism: Interaction of Sensitivity Modulation and Effector Redistribution 1  

UK PubMed Central (United Kingdom)

Our increasing capabilities for quantitative hormone analysis and automated high resolution growth studies have allowed a reassessment of the classical Cholodny-Went hypothesis of gravitropism. According...Full Text Available

1991-01-01

466

Further argument in support to the conjecture of a three-dimensional time  

Energy Technology Data Exchange (ETDEWEB)

It is shown that a relativistic point kinematics with one independent dilation of (scalar) proper time for each spatial freedom degree would give a really rigorous physical significance to the ordinary logical resolution of the clock paradox between systems in relative motion.

1985-01-01

467

Exploration technology  

Energy Technology Data Exchange (ETDEWEB)

The paper evaluates exploration technology. Topics discussed are: Visions; the subsurface challenge; the creative tension; the exploration process; seismic; geology; organic geochemistry; seismic resolution; integration; drilling; value creation. 4 refs., 22 figs.

1996-12-31

468

Epilogue - GES DISC - NASA  

Science.gov (United States)

Sep 9, 2009... a French Ariane rocket successfully launched a new Earth-observing satellite ... The payload is a pair of identical sensors known as "high-resolution ... the resulting image) are activated simultaneously by incoming radiation; ...

469

Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers  

International Nuclear Information System (INIS)

The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of ...

1998-06-01

470

Dose, exposure time, and resolution in Serial X-ray Crystallography  

CERN Document Server

The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution of the phase problem, and reconstruction ...

2007-01-01

471

Diagnostic quality of low resolution images for tele-woundcare.  

UK PubMed Central (United Kingdom)

The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available

1998-01-01

472

Developments of heavy-ion gas detectors at LNL  

Energy Technology Data Exchange (ETDEWEB)

The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.

1984-05-01

473

Detailed comparison of the structures and kinematics of simulated and observed barred galaxies  

CERN Document Server

We examine the observable properties of simulated barred galaxies including radial mass profiles, edge-on structure and kinematics, bar lengths and pattern speed evolution for detailed comparison to real systems. We have run several simulations in which bars are created through inherent instabilities in self-consistent simulations of a realistic disc+halo galaxy model with a disc-dominated, flat rotation curve. These simulations were run at high (N=20M particles) and low (N=500K) resolution to test numerical convergence. We determine the pattern speeds in simulations directly from the phase angle of the bar versus time and the Tremaine-Weinberg method. Fundamental dynamics do not change between the high and low resolution, suggesting that convergence has been reached in this case. We find the higher resolution is needed to simulate structural and kinematic properties accurately. The edge-on view of the ...

2003-01-01

474

Crystal structure of the human adenovirus proteinase with its 11 amino acid cofactor.  

UK PubMed Central (United Kingdom)

The three-dimensional structure of the human adenovirus-2 proteinase complexed with its 11 amino acid cofactor, pVIc, was determined at 2.6 A resolution by X-ray crystallographic analysis. The fold...Full Text Available

1996-04-15

475

Bragg curves of fission fragments in gases  

Energy Technology Data Exchange (ETDEWEB)

An unexpectedly high probability of collisions between the fission particles and the atoms in an ionization chamber along the entire particle track causes a strong fluctuation of the shapes of the Bragg curves. This fluctuation imposes an upper limit of the charge resolution ..delta..Z/Z which can be achieved.

1986-03-01

476

An unsupervised classification method for inferring original case locations from low-resolution disease maps  

UK PubMed Central (United Kingdom)

BackgroundWidespread availability of geographic information systems software has facilitated the use of disease mapping in academia, government and private sector. Maps that display...Full Text Available

477

APOD: January 25, 1997 - M51: The Whirlpool Galaxy  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: The Whirlpool Galaxy Credit: W. Keel (U. Alabama), 1.1-meter Hall Telescope, Lowell Observatory...

2011-10-07

478

APOD: December 18, 1995 - M51: The Whirlpool Galaxy  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: The Whirlpool Galaxy Credit: 1.1 Meter Hall Telescope, Lowell Observatory, Bill Keel (U. Alabama)...

2011-10-07

479

APOD: 2011 January 26 - The Whirlpool Galaxy in Infrared Dust  

Science.gov (United States)

Clicking on the image will bring up the highest resolution version available. The Whirlpool Galaxy in Infrared Dust Credit: Infrared: NASA, ESA, M. Regan & B. Whitmore (STScI),...

2011-10-07

480

APOD: 2006 November 11 - M51: Cosmic Whirlpool  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: Cosmic Whirlpool Credit: S. Beckwith (STScI) Hubble Heritage Team, (STScI/AURA), ESA, NASA...

2011-10-07

481

APOD: 2005 April 28 - M51: Cosmic Whirlpool  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: Cosmic Whirlpool Credit: S. Beckwith (STScI) Hubble Heritage Team, (STScI/AURA), ESA, NASA...

2011-10-07

482

APOD: 2004 September 5 - M51: The Whirlpool Galaxy in Dust and...  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: The Whirlpool Galaxy in Dust and Stars Credit: Credit: N. Scoville (Caltech), T. Rector (U....

2011-10-07

483

APOD: 2002 July 11 - M51: X Rays from the Whirlpool  

Science.gov (United States)

picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...

2011-10-07

484

APOD: 2001 April 10 - M51: The Whirlpool Galaxy in Dust and Stars  

Science.gov (United States)

on the picture will download the highest resolution version available. M51: The Whirlpool Galaxy in Dust and Stars Credit: N. Scoville (Caltech), T. Rector ( (NOAO) et al.,...

2011-10-07

485

APOD: 2000 May 27 - M51: The Center Of The Whirlpool  

Science.gov (United States)

will download the highest resolution version available. M51: The Center Of The Whirlpool Credit: N. Panagia (STScI, ESA), NASA Explanation: In the center of M51, a spiral...

2011-10-07

486

14 - NASA  

Science.gov (United States)

... and mean rainfall rates, Rm, in the liquid hydrometeor layers using the .... large latitudinal movement of cirrus cloud cover with the changing seasons. ... We study the statistical distribution of PSCs by particle composition using .... the high resolution Cloud Particle Imager (CPI) and standard PMS 2D-C and ...

487

Structure functions at low Q^2: higher twists and target mass effects  

Energy Technology Data Exchange (ETDEWEB)

We review the physics of structure functions at low Q{sup 2}, focusing on the phenomenon of quark-hadron duality and the resonance-scaling transition, both phenomenologically and in the context of quark models. We also present a new implementation of target mass corrections to nucleon structure functions which, unlike existing treatments, has the correct kinematic threshold behavior at finite Q{sup 2} in the x -> 1 limit.

2006-05-22

488

Production of "2"0"3Pb by proton irradiation of Bi  

International Nuclear Information System (INIS)

Production of lead-203 by proton irradiation of bismuth metal has been investigated as a replacement method for commercially available lead-203. Targets of bismuth metal (0.1 cm thick) were irradiated for periods of 1-3 hours with 90 MeV protons. After processing of the target, the estimated yield of lead-2-3 was 30 millicuries/microamp.

1990-06-24

489

Modeled Neutron Induced Nuclear Reaction Cross Sections for Radiochemistry in the region of Iridium and Gold  

International Nuclear Information System (INIS)

We have developed a set of modeled nuclear reaction cross sections for use in radiochemical diagnostics. Systematics for the input parameters required by the Hauser-Feshbach statistical model were developed and used to calculate neutron induced nuclear reaction cross sections for targets ranging from osmium (Z = 76) to gold (Z = 79). Of particular interest are the cross sections on Ir and Au including reactions on isomeric targets.

2008-02-01

490

Highly efficient gene silencing using perfect complementary artificial miRNA targeting AP1 or heteromeric artificial miRNA targeting AP1 and CAL genes  

UK PubMed Central (United Kingdom)

Gene silencing is a useful technique for elucidating biological function of genes by knocking down their expression. A recently developed artificial microRNAs (amiRNAs) exploits an endogenous...Full Text Available

2009-03-01

491

Electron accelerator unit for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.

1987-01-27

492

Electron accelerator unit for electron beam therapy  

International Nuclear Information System (INIS)

An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.

493

Development of High-Efficiency Low-Lift Vapor Compression System - Final Report  

Energy Technology Data Exchange (ETDEWEB)

PNNL, with cofunding from the Bonneville Power Administration (BPA) and Building Technologies Program, conducted a research and development activity targeted at addressing the energy efficiency goals targeted in the BPA roadmap. PNNL investigated an integrated heating, ventilation and air conditioning (HVAC) system option referred to as the low-lift cooling system that potentially offers an increase in HVAC energy performance relative to ASHRAE Standard 90.1-2004.

2010-03-31

494

Designing Human m1 Muscarinic Receptor-Targeted Hydrophobic Eigenmode Matched Peptides as Functional Modulators  

UK PubMed Central (United Kingdom)

A new proprietary de novo peptide design technique generated ten 15-residue peptides targeting and containing the leading nontransmembrane hydrophobic autocorrelation wavelengths, “modes”,...Full Text Available

2004-03-01