Invading melanoma spreads to local and unpredictable distant location at the early stages of its development. It is justifiable, therefore, to classify the disease as a systemic disorder. This requires a systemic treatment that reaches all melanoma cells irrespective of whether they are singly dispersed and in circulation or already forming solid tumours of various sizes. Targetedradiotherapy affects directly and selectively cancer cells provided an appropriate radionuclide and its carrier are chosen. Melanoma is a pigmented tumour. Methylene blue (MTB)) accumulates selectively in melanoma cells due to its exceptionally high affinity to melanin. MTB serves, therefore, as a carrier for radionuclides. "2"1"1At-MTB has proved to be particularly effective in treating disseminated melanoma when administered systemically and, at the same time, non-toxic to normal non-pigmented and pigmented organs. (authors)
Obtained experimental data on integral cross sections (ICS) of inelastic scattering of 50.5 MeV #alpha# particles with the excitation of "6","7Li, "9Be, "1"2","1"3C, "1"4C, "1"4N, "2"0Ne, "2"4Mg, "2"8Si nucleus low-lying energy levels are discussed. Regularities, detected in the behaviour of ICS forward scattering for 20-90 deg angles and backscattering for 90-160 deg angles for the target-nucleus under investigation are considered. Effect of reaction open channel number on #alpha#-particle scattering ICS where n,p,d- and #alpha#-channels were considered as the main channels for all the target-nuclei, is discussed. Dependence of #alpha#-particle scattering ICS on the target-nucleus level excitation energy and dependences of reaction open channel number on the channel spin, calculated for 50.5 MeV #alpha# ...
Using U-120 cyclotron in the course of correlation experiment one studied mechanisms of excitation and decay of "1"2C nucleus states resulting from irradiation of deuterium-polyethylene target by 27.2 MeV energy #alpha#-particle beam via recording of #alpha#-#alpha#-coincidence simultaneously with investigations of #alpha# + d-interactions. Production of "1"2C excited states decaying with the escape of #alpha#-particle and "8Be nucleus in the ground and the excited states is the basic mechanism of the studied #alpha# + "1"2C interaction
The possibilities, advantages, and difficulties of determining nuclear matter densities by elastic scattering of alpha-particles are generally discussed. On the basis of particular experimental data - 104 MeV alpha-particle scattering from "4"0,"4"2,"4"4,"4"8Ca - a refined folded potential is introduced using a density-dependent alpha-nucleon-interaction and target nucleus densities described by Fourier-Bessel-series. Thereby, the total nucleon densities of these isotopes were determined with little model dependence. The resulting root-mean-square radii and density differences are compared with other experimental results obtained by different methods. (orig.).
The elastic scattering angular distributions of 25 MeV alphaparticles scattered from "7"3Ge, "8"9Y, "9"0Zr, "9"1Zr"9"4Zr, "9"3Nb, "4"4Ca and "4"5Sc have been measured experimentally, and fitted using a conventional optical model. (author).
A theoretical model is proposed for analyzing elastic scattering of 100-150 MeV #alpha#-particles on intermediate mass nuclei. It is shown that, within the scope of this model accounting for inhomogeneous target-nucleus density, an anomalous growth of differential cross section of elastic scattering in the region of average angles can be explained.
Results of an experimental study of the interaction of 140 MeV alphaparticles with /sup 90/Zr nuclei resulting in fragmentation of the alphaparticle are reported. The experimental observations of the study are analyzed and are found to show that alphaparticle breakup reactions leading to at least 4-body final states, composed of two charged alphaparticle fragments, contribute significantly to the singles yield of charged fragments observed at a fixed forward angle. The conclusions are based on coincidence measurements where one charged fragment is detected at a small forward angle which remains fixed, while the second charged fragment is detected at a series of coplanar secondary angles. The largest coincidence charged particle yield for the multiparticle final state events results from /sup 90/Zr(..cap alpha..,pp)X ...
Results of an experimental study of the interaction of 140 MeV alphaparticles with _9_0Zr nuclei resulting in fragmentation of the alphaparticle are reported. The experimental observations of the study are analyzed and are found to show that alphaparticle breakup reactions leading to at least 4-body final states, composed of two charged alphaparticle fragments, contribute significantly to the singles yield of charged fragments observed at a fixed forward angle. The conclusions are based on coincidence measurements where one charged fragment is detected at a small forward angle which remains fixed, while the second charged fragment is detected at a series of coplanar secondary angles. The largest coincidence charged particle yield for the multiparticle final state events results from _9_0Zr(#alpha#,pp)X reactions, ...
Alpha-particle emission induced by neutron bombardment of carbon has been studied from threshold to over 30 MeV using the spallation neutron source at WNR/LAMPF. Targets include thin foils of CH{sub 2} and thicker foils of CH and polycrystalline graphite. Comparisons are made with evaluated data. Values for KERMA (kinetic energy released in materials) based on the results will be presented and compared with those obtained through other experimental approaches.
The "6"2Zn-"6"2Cu generator system is one of the few which yield a pure positron emitting daughter. The authors have developed a method for the preparation of this generator system following 32 MeV #alpha# particle bombardment of nickel targets. The chemical processing involves two stages: first a hydrous zirconium oxide column is used at pH 4-5 to separate the zinc and copper activities produced in the target nickel, and secondly, a conventional anion exchange column is used to retain the "6"2Zn and remove all copper activities in 2M HCl. This column serves as the "6"2Cu generator which will yield pure "6"2Cu repeatedly, free from "6"2Zn and other impurities, in a mixture of HCl and NaCl. A method is outlined also to obtain a solution of "6"2Zn using the hydrous zirconium oxide (HZO) column. "6"1Cu can be prepared as a by-product in the above procedure, but a method for the preparation of "6"1Cu alone ...
Objective: Pretargeting is the concept that combines optimal delivery of the antibody and rapid capture and elimination of the radioactivity. In this study, we evaluated the potential of antibody pretargeting to enable the tumor-targeting {sup 212}Pb for in vivo generation of {sup 212}Bi for {alpha} particleradiotherapy. Methods: The {sup 212}Pb/{sup 212}Bi chelate of DOTA-biotin, as well as their {gamma}-emitting analogues, {sup 203}Pb and {sup 205}Bi, was prepared and characterized. The radiolabeled compounds were injected in animals for evaluation of tumor targeting and normal tissue uptake and retention. In the pretargeting protocol, injection of 400 {mu}g of NR-LU-10 antibody-streptavidin conjugate was given at t=0 h, then 100 {mu}g of N-acetyl-galatosamine-biotin clearing agent was injected at t=20-24 h; finally, 1 {mu}g of {sup 212}Pb/{sup 212}Bi-DOTA-biotin was injected 6 h ...
TiH{sub 2} and TiD{sub 2} thick targets were bombarded with 100 to 200 keV protons. Evidence for nuclear reactions was obtained by means of a surface barrier particle detector. Proton irradiation of TiD{sub 2} produced the following observations: {alpha} particle emission identified as (p, {alpha}) reactions from {sup 11}B and {sup 7}Li impurities in the target at ppm concentrations; and {approx}3 MeV proton and {approx}1 MeV triton emission from secondary D-D reactions caused by elastic scattering of the primary proton with a target deuteron. A 3.9 MeV {alpha} particle peak measured by others was not observed. (author)
Comparisons of calculated neutron yield distributions from #alpha#-particle induced reactions on thick targets are made with measured data to analyze the initial reaction process in the framework of the exciton (hybrid) model code ALICE91 (M. Blann, Lawrence Livermore National Laboratory Report UCID 19614, 1982). We have considered two reaction mechanisms: dissolution of the #alpha# in the nuclear field, and preequilibrium processes initiated by #alpha#-nucleon collisions. Both these processes seem to contribute to the emitted neutron spectra in varying proportions depending on the incident #alpha# energy and possibly on the target nucleus. Contributions from other processes appear to be non-negligible.
A 5.76 MeV alpha-particle group has been observed in Am and Bk sources separated from a CERN W target. The data are interpreted due to the production of long-lived isomeric states in /sup 236/Am and /sup 236/Bk which decay to /sup 236/Pu. The possibility of high spin states as well as of shape isomeric states is raised.
K-shell x-ray production cross sections and K#beta#/K#alpha# ratios have been measured for thin targets of Ti, V, Cr, Fe, Ni, Cu, Zn, Ga, As, Se, Rb, Sr, and Y for 0.5- to 2.5-MeV alphaparticles. The experimental values are compared to the nonrelativistic plane-wave Born approximation (PWBA), the binary-encounter approximation, and the PWBA with binding energy and Coulomb deflection corrections. The PWBA with corrections provides the best agreement with the experimental cross sections.
Excitation functions ({alpha},3n) and ({alpha},4n) for {sup 209}Bi have been measured up to 60 MeV {alpha}-particle energy. The excitation functions are measured at 15{alpha}-particle energies by a stack foil technique in two steps. Excitation functions for the above two reactions have been reported for the first time in the energy range from 40 to 60 MeV. The measured experimental values are compared with the geometry-dependent hybrid (GDH) model in which the emission of particles prior to the equilibrium decay is taken into account whenever the interaction of projectile with the target nucleus is considered. It is found that the compound nucleus decay mechanism alone is unable to explain the experimental trend of our data. The initial exciton number 4 with different configurations has been tested and it is concluded that the configuration (2n + 2p + 0h) gives the best fit to the experimental data. (author).
Excitation functions (#alpha#,3n) and (#alpha#,4n) for "2"0"9Bi have been measured up to 60 MeV #alpha#-particle energy. The excitation functions are measured at 15#alpha#-particle energies by a stack foil technique in two steps. Excitation functions for the above two reactions have been reported for the first time in the energy range from 40 to 60 MeV. The measured experimental values are compared with the geometry-dependent hybrid (GDH) model in which the emission of particles prior to the equilibrium decay is taken into account whenever the interaction of projectile with the target nucleus is considered. It is found that the compound nucleus decay mechanism alone is unable to explain the experimental trend of our data. The initial exciton number 4 with different configurations has been tested and it is concluded that the configuration (2n + 2p + 0h) gives the best fit to the experimental data. (author).
Theoretical interpretation of fast-charged-particle spectra, observed in the #alpha#-particle-induced reactions on the s-d shell nuclei (A = 24-28), in terms of the Intranuclear Cascade Model and the GDH exciton model (ALICE) is presented. The de-excitation of the excited residual nuclei is accounted for by the evaporation process. The theoretically predicted fast-proton and #alpha#' spectral shapes compare reasonably well with the corresponding measured spectra. However, the magnitude depends critically (as expected) on the reaction cross section employed by the model. As a first step to improve the model predictability of the reaction products, a closer look at the calculation of the #alpha#-particle reaction cross sections was undertaken. A microscopic approach using the optical theorem of Glauber's theory was employed to estimate the #alpha#-induced reaction cross sections for the light target nuclei under ...
A simple electromagnetic transport system was constructed to identify very rare positrons produced in a powerful laser beam interaction with a target. Testing experiments were carried out with CO[sub 2]-laser (10[sup 12] W/cm[sup 2]) beam pulses ([tau] = 50 ns, f = 0.01 Hz) focused on the copper target, as well as with a 96 MeV alpha-particle beam irradiated carbon target. The results showed that the developed system could be effectively used for positron identification and evaluation of their energy by means of a time-of-flight method. The computerized system to deal with this problem, together with others related to the power laser beam interaction with targets, has been constructed. (orig.).
We measured neutron time-of-flight spectra from 90 MeV protons and 140 MeV alphaparticles bombarding thin targets of Al, Ni, Zr, and Bi at laboratory angles between 20_0 and 135_0. The low-energy (5 to 45 MeV) portions of the spectra were measured with 5 cm diameter by 5 cm deep NE-213 counters at 1 m flight paths with n-#betta# pulse-shape discrimination. The high-energy (35 to 150 MeV) portions of the spectra were measured with 12.7 cm diameter by 10.2 cm deep NE-102 counters at flight paths of 2.0 to 5.0 m. The proton-induced measured neutron spectra reveal three distinct energy regions: a low-energy evaporation region, a high-energy region dominated by the quasifree scattering process, and an intermediate-energy region dominated by multistep, preequilibrium processes. In the latter two regions, the spectra show strong angular dependence. The alpha-particle induced neutron spectra show these same ...
Inelastic scattering of #alpha#-particles in 22-24 MeV energy range on "1"8o o, "1"9f, "2"0Ne, "2"2Ne nuclei is investigated. Measurements of excitation functions were conducted for the beam of Leningrad University cyclo otron at several angles in 15-165 deg range of laboratory system with 2.5 deg spacing. The error of determining absolute cross sections equals +-20% for "2"2Ne and +-12% for other nuclei. Angular distributions have the differaction character, are similar in form for all nuclei, the values of differential cross- -sections don't exceed the rutherford values. The dependence of integral cross-sections on the energy of level excitation is similar to the exponential d dependence of cross-sections of production of the given element isotopes on the gergy difference of masses of final nuclear products in the reactions of deeply inelastic transfers with heavy ions. The observed isotopic effect in the value of cross-sections of elastic and inelastic ...
Complete energy spectra and angular distributions of the light charged particles (A < or = 4) were measured for the bombardment of "2"7Al, "5"8Ni, "9"0Zr, "2"0"9Bi, and "2"3"2Th with 140 MeV #alpha# particles. The spectral shapes of a given emitted particle are very similar for all target nuclei except in the region of the evaporation peak. The slopes of the energy spectra in the forward direction become steeper as the mass of the observed particle decreases and vary very rapidly with angles. The experimental data can be characterized by compound nuclear evaporation processes at low energies, or at backward angles, and by direct reactions, nonequilibrium components and projectile breakup processes at high energies and forward angles. The breakup cross section for #alpha# particles is found to be appreciable. The total yield of light charged particles is approximately a factor ...
A radiochemical charged particle activation procedure for production and separation of carrier free {sup 52,56}Mn, {sup 55,56,58}Co and {sup 56,57}Ni has been developed. The radioisotopes produced on bombardment of an iron foil target with a 40 MeV {alpha}-particle beam through the nuclear reactions, Fe({alpha}, {alpha}pxn){sup 52,56}Mn, Fe({alpha}, pxn){sup 55,56,58}Co and Fe({alpha}, nx){sup 56,57}Ni, have been separated by LLX. The target element and the activation products have been sequentially separated from an HCl medium using diethylether and the liquid anion exchanger, TIOA, as extractants. Extent of separation and purity of the carrier free radiotracers at different stages of their LLX separation have been verified by taking recourse to {gamma}-ray spectrometry. (Author).
Bremsstrahlung emitted in the {alpha}+p reaction at 50 MeV/nucleon was studied using a 200 MeV {alpha}-particle beam and a liquid hydrogen target. Double-differential photon cross sections were measured over a wide range of angles and energies. Coherent bremsstrahlung was found to be strong for all photon energies. The cross section is enhanced at the highest photon energies and is characteristic of direct capture to the unbound {sup 5}Li ground and first excited state. With direct capture as a limiting case of coherent bremsstrahlung a consistent reaction picture can be obtained.
For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alphaparticle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like ...
Excitation functions (EFs) for the reaction "1"4"1Pr(#alpha#, n)"1"4"4Pm and "1"4"1Pr(#alpha#, 2n)"1"4"3Pm have been measured using "1"4"1Pr as a target up to 50 MeV #alpha#-particle energy. Stacked foil activation technique and #gamma#-ray spectroscopy using 100 cm"3 Ge (Li) detector, has been used. Excitation functions are also calculated theoretically using Blann's geometry dependent hybrid (GDH) model code ALICE-91, with and without inclusion of pre-equilibrium particle emission. It has been observed that high-energy tails of the EFs are dominated by pre-equilibrium reaction mechanism. With the accepted set of input parameter, initial exciton number n_0=4 (2p + 2n + 0h), a good qualitative agreement is found. However, quantitative agreement for this magic nucleus"1"4"1Pr is also good when theoretical calculations are normalized by a multiple factor of 0.5. (author)
The production methods for seven radioisotopes, Ga-67, Sr-85, Pd-103, In-111, Tu-167, Hg-197 and Pb-203, by using a classical 1.5m cyclotron in the Institute of Physics and Power Engineering, Obninsk, USSR, are described. At present, more than 50 cyclotrons in different countries are used for the production of radioisotopes applied to medicine. Radioisotopes are produced with the cyclotron in the I.Ph.P.E. in the form of irradiated targets, which are delivered to Moscow radiopharmaceutical factory, where radiopharmaceuticals are produced on the base of these targets. The cyclotron is operated in two regimes providing the acceleration of protons, deuterons and alpha -particles. Two types of target assemblies are used for irradiation, the one is intended for the internal beam, and the other is for the external beam. The reactions used for the production of seven radioisotopes ...
The production methods for seven radioisotopes, Ga-67, Sr-85, Pd-103, In-111, Tm-167, Hg-197 and Pb-203, by using a classical 1.5m cyclotron in the Institute of Physics and Power Engineering, Obninsk, USSR, are described. At present, more than 50 cyclotrons in different countries are used for the production of radioisotopes applied to medicine. Radioisotopes are produced with the cyclotron in the I.Ph.P.E. in the form of irradiated targets, which are delivered to Moscow radiopharmaceutical factory, where radiopharmaceuticals are produced on the base of these targets. The cyclotron is operated in two regimes providing the acceleration of protons, deuterons and alpha -particles. Two types of target assemblies are used for irradiation, the one is intended for the internal beam, and the other is for the external beam. The reactions used for the production of seven radioisotopes ...
Current applications of ..cap alpha..-particle spectrometry in post-irradiation research and reprocessing are reviewed. Implementation of procedures and techniques described in the literature to the particular samples at S.C.K./C.E.N. often results in a combined radiochemical method where ..cap alpha..-particle spectrometry is used to complement or enforce results obtained by other methods. Typical cases are reported and results obtained by different methods are compared to the results obtained by ..cap alpha..-particle spectrometry.
The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alphaparticles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alphaparticle sources with energies ranging from 3 to 10 MeV. ...
In the case of inelastic scattering of alphaparticles to the 3"+ state, the averaged angular distributions show a characteristic shape, corresponding to the excitation of such an unnatural parity state by alphaparticles in the compound nucleus process. The modified Hauser-Feshbach cross-section calculations give a good description of the averaged distributions for the alphaparticle scattering to the 3"+ state and the compound nucleus parameters could be extracted. The calculations of the compounds nucleus contributions to the other states in the case of 24 MeV alphaparticle scattering from "2"8Si show that this contribution is not negligible and in the case of the scattering to the 4"+ state seems to be dominant. (Z.M.).
Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).
Thick-target recoil ranges of radioactive nuclei produced in 30-200 MeV alpha-particle bombardment of /sup 59/Co have been used to deduce the longitudinal momentum transfer per projectile nucleon (psub(parallel)/A) as a function of residue mass and bombarding energy. The average value of psub(parallel)/A increases monotonically with bombarding energy and reaches a maximum value of proportional160 MeV/c at proportional23 MeV/u, and decreases thereafter. The maximum value of psub(parallel)/A is equal to the incident momentum up to proportional23 MeV/u and saturates at a value of proportional220 MeV/c beyond this energy.
A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.
A new class of low aspect ratio toroidal hybrid stellarators is found using a more general plasma confinement optimization criterion than quasisymmetrization. The plasma current profile and shape of the outer magnetic flux surface are used as control variables to achieve near constancy of the longitudinal invariant J{sup {asterisk}} on internal flux surfaces (quasiomnigeneity), in addition to a number of other desirable physics target properties. A range of compact (small aspect ratio A), low plasma current devices have been found with significantly improved confinement, both for thermal as well as energetic (collisionless) particle components. With reasonable increases in magnetic field and geometric size, such devices can also be scaled to confine 3.5 MeV alphaparticle orbits.
A new class of low aspect ratio toroidal hybrid stellarators is found using more general plasma confinement optimization criterion than quasi-symmetrization. The plasma current profile and shape of the outer magnetic flux surface are used as control variables to achieve near constancy of the longitudinal invariant J* on internal flux surfaces (quasi-omnigeneity), in addition to a number of other desirable physics target properties. We find that a range of compact (small aspect ratio A), high {beta} (ratio of thermal energy to magnetic field energy), low plasma current devices exist which have significantly improved confinement both for thermal as well as energetic (collisionless) particle components. With reasonable increases in magnetic field and geometric size, such devices can also be scaled to confine 3.5 MeV alphaparticle orbits.
In the Introduction the history of the cascade probabilistic method development is described. The calculation model for different charged particles cascade probabilistic functions (CPF) was considered. A new analytical expressions for CPF for electrons, protons, alpha-particles and ions are obtained as well. A new results on mathematical analysis, algorithms, and calculation of CPF with taking into account charged particles energy losses on computer are cited. The peculiarities of these functions are analyzed. The detail analysis of these function behavior in relation from flying particles energy, target atomic number, generation and registration depth, and interactions number is carried out. The program packages in the Windows medium is developed on the visual programming languages: Visual Basic 6.0, Delphi 6.0, C++ Builder 6.0.
TiH{sub 2} and TiD{sub 2} thick targets were bombarded with 100 to 200 keV protons or deuterons. Evidence for nuclear reactions was obtained by means of a surface barrier particle detector. Deuteron irradiation of TiD{sub 2} produced these observations: copious {approx}2.5 MeV neutrons and {approx}3 MeV protons from direct D-D reactions; gamma rays from p,{gamma} and n,{gamma} reactions; {approx}14 MeV protons from the secondary d({sup 3}He, p){alpha} reaction; and a signal between {approx}6-12 MeV that Kasagi et al. has tentatively identified as protons from the fusion of three deuterium nuclei. However, this signal has in it a strong interference signal from either neutrons or gamma rays that directly deposit energy in the detector. This interference spectra was measured by placing a thick absorber in front of the detector that stops up to 20 MeV protons, but not gamma rays or neutrons. More experiments must be done before we can confirm or deny the existence in ...
Neutron time-of flight spectra were measured from 90 MeV protons and 140 MeV alpha-particle bombardment of Al, Ni, Zr, and Bi at laboratory angles between 20/sup 0/ and 130/sup 0/. The proton induced neutron spectra reveal three distinct energy regions; a low energy evaporation region, a high-energy region dominated by quasi-free scattering processes and an intermediate-energy region dominated by multi-step, pre-equilibrium processes. In the latter two regions, the spectra show strong angular dependence. The alpha-induced neutron spectra show these same distinct energy regions plus an exponential fall-off above the beam energy per nucleon. The high-energy portions of the forward-angle neutron and proton cross sections are in ratios consistent with the assumption that single nucleon-nucleon scattering dominates. For heavy-mass targets, the low-energy evaporation regions show neutron yields larger than proton yields. The proton-to-neutron ratios ...
Neutron time-of flight spectra were measured from 90 MeV protons and 140 MeV alpha-particle bombardment of Al, Ni, Zr, and Bi at laboratory angles between 20"0 and 130"0. The proton induced neutron spectra reveal three distinct energy regions; a low energy evaporation region, a high-energy region dominated by quasi-free scattering processes and an intermediate-energy region dominated by multi-step, pre-equilibrium processes. In the latter two regions, the spectra show strong angular dependence. The alpha-induced neutron spectra show these same distinct energy regions plus an exponential fall-off above the beam energy per nucleon. The high-energy portions of the forward-angle neutron and proton cross sections are in ratios consistent with the assumption that single nucleon-nucleon scattering dominates. For heavy-mass targets, the low-energy evaporation regions show neutron yields larger than proton yields. The proton-to-neutron ratios observed ...
The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The primary lesion and nodal mass regressed by 16.2% and 32.5%, respectively. Adapted GTVs and reduced plan...
Alphaparticle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alphaparticles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alphaparticles determined by the positive current flowing from the foils. 2 refs., 3 figs.
We develop the formalism of a unified semi-microscopic description of low-energy proton and {alpha}-particle interaction with nuclei. We analyze elastic and inelastic proton scattering at the energy 25.05 MeV and {alpha}-particle scattering at the energy 104 MeV by the {sup 90}Zr nucleus. Information is obtained on differences in the deformation of the proton and neutron distributions. We study the energy dependence of the semi-microscopic {alpha}-particle potential including the energy dependence of the potential geometry.'' We analyze the change in angular distributions of elastically scattered {alpha} particles with increase of energy and the contribution to the scattering cross section from nucleon-nucleon correlations.
The study of the {alpha}-particle energy distributions associated with ND and SD states in {sup 151,152}Dy has been carried out. The Dy isotopes were produced in the reaction {sup 37}Cl+{sup 123}Sb at 191 MeV via the ({alpha}5n) and ({alpha}4n) channels, respectively. In {sup 151}Dy the {alpha}-particle energy distributions associated to ND and SD are very different from each other, both at the low and high energy sides inducing a difference of 3 MeV in the {alpha}-particle mean energy. In {sup 152}Dy the situation is different; the {alpha}-particle spectral shapes are similar and a difference in the {alpha}-particle mean energy of only 0.7 MeV is deduced. A description in terms of energy localization of entry states is given. (orig.)
Several reactions producing odd-Z transactinide compound nuclei were studiedwith the 88-Inch Cyclotron and the Berkeley Gas-Filled Separator at the LawrenceBerkeley National Laboratory. The goal was to produce the same compound nucleus ator near the same excitation energy with similar values of angular momentum via differentnuclear reactions. In doing so, it can be determined if there is a preference in entrancechannel, because under these experimental conditions the survival portion of Swiatecki, Siwek-Wilcznska, and Wilczynski's"Fusion By Diffusion" model is nearly identical forthe two reactions. Additionally, because the same compound nucleus is produced, theexit channel is the same. Four compound nuclei were examined in this study: 258Db, 262Bh, 266Mt, and 272Rg. These nuclei were produced by using very similar heavy-ion induced-fusion reactions which differ only by one proton in the projectile or target nucleus (e.g.: 50Ti + 209Bi vs. ...
A technique has been developed for high resolution alphaparticle spectroscopy from track length determination in CR-39 plastic. On individual tracks an energy resolution deltaE close to the range straggling limit is obtainable. For 6 MeV alpha-particle deltaE is proportional 35 keV on individual particles and for groups of particles deltaE proportional 20 keV can be achieved using certain data selection criteria. At 100 keV on individual particles deltaE is proportional 20 keV. The analysis requires 1) a knowledge of the track-etch rate (Vsub(T))-range relationship and 2) a theoretical understanding of alpha-particle track structure in CR-39 as a function of particle energy, dip angle and degree of etching. The structure of alpha-particle etched tracks in CR-39 is described and two methods of analysis discussed. Examples are given of the resolution attainable on tracks of ...
A computer-assisted rotation and stationary conformation radiotherapy system with overrunning multileaf collimators has been developed. This system can produce any shape of target volume, including a number of target areas outside the axis of the rotation, regardless of the location of the axis at 360"0 rotation irradiation. In addition, by changing the dose rate and deleting a partial region within a field, multiple stationary irradiation can produce more homogeneous target volumes - thus avoiding excessive irradiation to critical organs - than the rotation technique. (orig.).
Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. (authors). 28 refs.
The high frequency, low mode number toroidicity-induced Alfven eigenmodes (TAE) are shown to be driven unstable by the circulating and/or trapped {alpha}-particles through the wave-particle resonances. Satisfying the resonance condition requires that the {alpha}-particle birth speed v{sub {alpha}} {ge} v{sub A}/2{vert bar}m-nq{vert bar}, where v{sub A} is the Alfven speed, m is the poloidal model number, and n is the toroidal mode number. To destabilize the TAE modes, the inverse Landau damping associated with the {alpha}-particle pressure gradient free energy must overcome the velocity space Landau damping due to both the {alpha}-particles and the core electrons and ions. The growth rate was studied analytically with a perturbative formula derived from the quadratic dispersion relation, and numerically with the aid of the NOVA-K code. Stability criteria in terms of the ...
The cross sections for /sup 250/Fm, /sup 244-246/Cf, /sup 242-244/Cm, and /sup 242/Am/sup g-italic/ produced by the /sup 12/C+ /sup 242/Pu and the /sup 16/O+ /sup 238/U reactions leading to the same compound nucleus of /sup 254/Fm have been measured by using radiochemical methods. The excitation functions show that the difference between the /sup 12/C+ /sup 242/Pu and the /sup 16/O+ /sup 238/U reactions can be attributed mainly to the Coulomb barriers. Our results were compared with others reported previously for /sup 22/Ne+ /sup 232/Th, /sup 12/C+ /sup 238/U, /sup 12/C+ /sup 240,241/Pu, /sup 13/C+ /sup 241/Pu, /sup 16/O+ /sup 233/U, and /sup 16/O+ /sup 242/Pu reaction systems, and support a mechanism involving transfer of ..cap alpha..-particle clusters (C,Be,He) from projectile to target for the production of Cf and Cm isotopes.
The cross sections for /sup 250/Fm, /sup 244-246/Cf, /sup 242-244/Cm, and /sup 242/Am/sup g/ produced by the /sup 12/C+ /sup 242/Pu and the /sup 16/O+ /sup 238/U reactions leading to the same compound nucleus of /sup 254/Fm have been measured by using radiochemical methods. The excitation functions show that the difference between the /sup 12/C+ /sup 242/Pu and the /sup 16/O+ /sup 238/U reactions can be attributed mainly to the Coulomb barriers. Our results were compared with others reported previously for /sup 22/Ne+ /sup 232/Th, /sup 12/C+ /sup 238/U, /sup 12/C+ /sup 240,241/Pu, /sup 13/C+ /sup 241/Pu, /sup 16/O+ /sup 233/U, and /sup 16/O+ /sup 242/Pu reaction systems, and support a mechanism involving transfer of #alpha#-particle clusters (C,Be,He) from projectile to target for the production of Cf and Cm isotopes.
Experimentally investigated nuclear reactions for production of no-carrier-added "7"7Br and "7"7Kr were critically surveyed. The survey covered nine reactions for the formation of "7"7Br and six reactions for "7"7Kr. Both radionuclides are simultaneously produced in many of the studied nuclear processes. The experimental data were compared with the results of nuclear model calculations based on the computer code ALICE-IPPE and the third version of TALYS-based Evaluated Nuclear Data Library, TENDL-2010. Good agreement was found over extended energy regions for the p-, "3He- and #alpha#-particle induced reactions on several target materials. In case of d-induced reactions, however, considerable discrepancies were noted between the experimental and theoretical data. The concordant sets of experimental cross section data for each reaction were fitted by a polynomial function to obtain a trend curve. From the thus obtained trend curves the yields of ...
Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure ...
Purpose: We present an update analysis of the multiinstitutional Ewing's sarcoma study CESS 86. Methods and Materials: From January 1986 through June 1991, 177 patients with localized Ewing's sarcoma of bone, aged 25 years or less, were recruited. Chemotherapy consisted of four 9-week courses of vincristine, actinomycin D, cyclophosphamide, and adriamycin (VACA) in low-risk tumors (extremity tumors =# 100 cm"3). Local therapy was an individual decision in each patient and was either radical surgery (amputation, wide resection) or resection plus postoperative irradiation with 45 Gy or definitive radiotherapy with 60 Gy (45 Gy plus boost). Irradiated patients were randomized concerning the type of fractionation in either conventional fractionation (once daily 1.8-2.0 Gy, break of chemotherapy) or hyperfractionated split-course irradiation simultaneously with the VACA/VAIA chemotherapy (twice daily 1.6 Gy, break of 12 days after 22.4 Gy and 44.8 Gy, total dose and ...
The charge distribution in the alphaparticle induced fission of "2"0"9Bi has been studied at alphaparticle energy of 55.7 MeV and 58.6 MeV. The fractional cumulative yields of "9"7Zr, "9"9Mo, "1"0"1Mo and "1"1"2Pd have been determined using gamma ray spectrometry. The charge distribution have been found to be broad. (author). 4 refs., 1 ta b.
Multiple myeloma is a highly radiosensitive skeletal malignancy, but bone-seeking radionuclides have not yet found their place in disease management. We previously reported that the proteasome inhibitor...Full Text Available
The interaction between a lower hybrid wave and a fusion alphaparticle displaces the alphaparticle simultaneously in space and energy. This results in coupled diffusion. Diffusion of alphas down the density gradient could lead to their transferring energy to the wave. This could, in turn, put energy into current drive. Here we calculate numerical solutions for the alpha energy transfer and study a range of conditions that are favourable for wave amplification from alpha energy. We find that it is possible for fusion alphaparticles to transfer a large fraction of their energy to the lower hybrid wave. The numerical calculation shows that the net energy transfer is not sensitive to the value of the diffusion coefficient over a wide range of practical values. An extension of this idea, the use of a lossy boundary to enhance the energy transfer, is investigated. ...
The interaction between a lower hybrid wave and a fusion alphaparticle displaces the alphaparticle simultaneously in space and energy. This results in coupled diffusion. Diffusion of alphas down the density gradient could lead to their transferring energy to the wave. This could, in turn, put energy into current drive. Here we calculate numerical solutions for the alpha energy transfer and study a range of conditions that are favourable for wave amplification from alpha energy. We find that it is possible for fusion alphaparticles to transfer a large fraction of their energy to the lower hybrid wave. The numerical calculation shows that the net energy transfer is not sensitive to the value of the diffusion coefficient over a wide range of practical values. An extension of this idea, the use of a lossy boundary to enhance the energy transfer, is investigated. ...
The interaction between a lower hybrid wave and a fusion alphaparticle displaces the alphaparticle simultaneously in space and energy. This results in coupled diffusion. Diffusion of alphas down the density gradient could lead to their transferring energy to the wave. This could, in turn, put energy into current drive. An initial analytic study was done by Fisch and Rax. Here the authors calculate numerical solutions for the alpha energy transfer and study a range of conditions that are favorable for wave amplification from alpha energy. They find that it is possible for fusion alphaparticles to transfer a large fraction of their energy to the lower hybrid wave. The numerical calculation shows that the net energy transfer is not sensitive to the value of the diffusion coefficient over a wide range of practical values. An extension of this idea, the use of a ...
We have mapped and studied the effects of MeV alpha-particle bombardment in polyvinylidene chloride (PVDC) and polyethylene (PE). We used 3.5 and 5.0 MeV alpha-particle incident beams and stacked polymer films to separate the contributing effects of the electronic ({var_epsilon}{sub e}) and nuclear ({var_epsilon}{sub n}) stopping powers. The electrical conductance and change in the chemical structures were measured by direct resistivity measurement, Raman microprobe, RBS and FTIR. The results indicate significant differences in the ({var_epsilon}{sub e}) and ({var_epsilon}{sub n}) effects at higher alpha-particle bombardment fluences. {copyright} {ital 1997 American Institute of Physics.}
The aetiology of childhood leukaemia remains generally unknown, although exposure to moderate and high levels of ionising radiation, such as was experienced during the atomic bombings of Japan or from radiotherapy, is an established cause. Risk models based primarily upon studies of the Japanese A-bomb survivors imply that low-level exposure to ionising radiation, including to ubiquitous natural background radiation, also raises the risk of childhood leukaemia. In a recent paper (Wakeford et al 2009 Leukaemia 23 770-6) we estimated the proportion of childhood leukaemia incidence in Great Britain attributable to natural background radiation to be about 20%. In this paper we employ the two sets of published leukaemia risk models used previously, but use recently published revised estimates of natural background radiation doses received by the red bone marrow of British children to update the previous results. Using the newer dosimetry we calculate that the best ...
The paper reports the recovery of zinc and cadmium following 6.1 MeV alphaparticle irradiation at 4.2 K as studied by means of electrical reistivity measurements. Specimens of 10 #mu#m thick have been used in order to obtain a homogeneous defect distribution over the whole thickness of the specimen. The pre-irradiation resistivity ratios were 700 and 750 for cadmium and zinc, respectively. (Auth.).
Tensor polarization of "6Li(2.18 MeV, 3"+) nucleus at inelastic scattering of #alpha# particles for #THETA#_l_a_b=45 deg angle is measured. The results are described by the calculations in terms of Born approximation of distorted waves with internucleonic interaction realistic potential.
Correlations of the Woods-Saxon four-parameter optical potential of scattering of 38 MeV #alpha# particles on sup(68)Zn have been analyzed. A search for discrete sets of potential parameters and functional ratios between different parameters is carried out.
The energy distribution of neutrons generated due to bombardment of 40 MeV alphaparticles on thick elemental tantalum is measured using threshold activation detectors. A method of unfolding the neutron spectrum from the activation data based on information-entropy weighted average solution is described. The present unfolding method does not require 'a priori' information about the shape of the solution spectrum. 16 refs. (author).
The effect of nuclear scattering on the suprathermal fusion probability of recoiling d-t nuclei under the impact of fusion products, a 14.1-MeV neutron and a 3.5 MeV alphaparticle, in thick pellets is investigated with the help of the Boltzmann-Fokker-Planck equation. Although the suprathermal fusion from alpha-particle recoils is quite small, the one originating from neutron recoils is considerable.
The emission of #alpha# particles in coincidence with the most deeply inelastic heavy-ion reactions has been studied for "1"8"1Ta + "1"6"5Ho at 1354 MeV laboratory energy and /sup nat/Ag + "8"4Kr at 664 MeV. #alpha# particle energy spectra and angular distributions, in coincidence with a projectile-like fragment, were acquired both in the reaction plane and out of the reaction plane at a fixed in-plane angle. The in-plane data for both systems are employed to show that the bulk of the #alpha# particles in coincidence with the deep-inelastic exit channel can be explained by evaporation from the fully accelerated fragments. Average velocity diagrams, #alpha#-particle energy spectra as a function of angle in several rest frames, and #alpha#-particle angular distributions are presented. The out-of-plane ...
The reactions of alphaparticles on natural abundance chromium have been studied between 40 and 110 MeV, in order to produce "5"2Fe for medical use. The yield of the reaction "5"2Cr(#alpha#,4n)"5"2Fe for Esub(#alpha#) = 85 #-># 53 MeV is only 30 #mu#Ci/#mu#Ah. (orig.).
Results on defect structure study and degree of molybdenum radiation hardening irradiated by fission neutrons and medium energy alpha-particles are presented. It is shown that molybdenum irradiation by alpha-particles and neutrons leads to different degree of material hardening for the same damage level. It is established that molybdenum radiation hardening is mainly defined by radiation defect clusters visible in electron microscope whose coefficient of rigidity depends on their size. 5 refs.; 6 figs.; 2 tabs. (author).
The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.
In the present work the excitation functions for the reactions "1"4"1Pr(#alpha#,n)"1"4"4Pm and "1"4"1Pr(#alpha#,2n)"1"4"3Pm have been measured experimentally below 50 MeV #alpha#-particle
Defects are produced in zinc by 6.1 MeV #alpha#-particle irradiation at 4.2 K and the subsequent recovery between 4.2 and 22 K. No evidence is found for free migration of an interstitial in the temperature range investigated. The recovery spectra reveal a series of substages which are ascribed to recombination of close Frenkel pairs. (author).
The experiments show that the fluence threshold of 316L SS irradiated by 1.8 MeV alphaparticle is between (0.8655-1.3457) x 10"1"8 #alpha#/cm"2, and the threshold decreases in the 1.5 MeV and 1.0 MeV alphaparticle irradiation. For the solid solution samples irradiated by 1.5 MeV alphaparticle, the threshold is below 0.5595 x 10"1"8#alpha#/cm"2, and for the 20% cold-worked sample, the threshold is between (0.8595-0.5063) x 10"1"8 #alpha#/cm"2. In 1.0 MeV alphaparticle irradiation, the threshold for the solid solution sample and 20% cold-worked sample is between (0.3073-0.1024) x 10"1"8 #alpha#/cm"2 and (0.4108-0.3063) x 10"1"8 #alpha#/cm"2 respectively. The difference of threshold of the two kinds of samples shows that the 20% cold-working can influence the occurrence of blistering
The aim of the paper is to investigate the process of #alpha#-particle breakup into two deuterons and to estimate the applicability of data on breakup for extraction of diffusivity parameter (a) in the framework of the diffraction approach. Measurements of absolute values of differential cross sections (DCS) of 96 MeV #alpha#-particle breakup on "5"8","6"4Ni are carried out in the limited angular range: #THETA#_1=22.5 deg, #THETA#_2=50, 55, 60, -50, -60 deg. Wide maxima typical for the process of incident #alpha#-particle breakup are observed in deuteron energy spectra. Measured DCS for #alpha#-particle breakup show distinct difference for "5"8Ni and "6"4Ni. The calculations describe satisfactorily this difference in the framework of the diffraction approach, if it is supposed that the diffusivity parameter for "5"8Ni nucleus has the value a=0.65 fm, and for "6"4Ni - a=0.85 fm.
Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alphaparticles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being ...
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning ...
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning ...
Although low-energy ion radiation has been proven to have a wide range of biological effects and led to fruitful achievements as a new mutagenic source for genetic modification, there still exist some disputes about its mutagenic mechanisms because of its short-penetrating property. In present research, Arabidopsis thaliana transgenic for GUS recombination substrate was used to evaluate the genomic instability induced by irradiations of alphaparticle (3.3MeV) and Low-energy-Argon ion (30 KeV). A pronounced effects of alphaparticle irradiation to Arabidopsis thaliana seedlings and Argon ion irradiation to seeds on the somatic homologous recombination frequency (sHRF) were reported. The sHRFs increased 1.88-fold and 2.42-fold, respectively, which indicated that the short-penetrating radiation could effectively induce the plant genomic instability in either dry seeds or seedlings with active metabolism. ...
'Improvement in understanding of the deposition of ambient dust particles on ECAM (Environmental Continuous Air Monitor) filters, reduction of the alpha-particle interference of radon progeny and other radioactive aerosols in different particle size ranges on filters, and development of ECAM''s with increased sensitivity under dusty outdoor conditions. As of May 1, 1998 (1/2 year into the project) the research-prototype 30-cm pulsed ionization chamber (PIC) is assembled and operational with an alphaparticle energy resolution of better than 45 keV for 5-MeV alphaparticles. Measurements of spectral resolution for alphaparticles from radon decay products have been made as a function of filter type and dust loading conditions. So far, a study of ten filter types has found that the best combination of resolution and ...
The feasibility of spectroscopic measurement of the velocity distribution of alphaparticle using the ablation cloud of a lithium or boron pellet was tested in the DT experiment of TFTR. The measurement was performed using a 10-channel narrow-band filtered spectrometer in the wavelength covering the 3.5 MeV alphaparticle Doppler broadening region of the He II 468.6 nm line and its vicinity. The spectra from a lithium pellet consists of the continuum bremsstrahlung background, lithium line emissions and possibly a 468.6 nm helium line. However, no clear evidence of alphaparticles was observed, even when boron pellets were injected. (orig.) 4 refs.
Over the last several years considerable concern has been expressed regarding the potential detrimental effects of radon and radon progeny on our health. The complex nature of the radon decay scheme, which involves the emission of a variety of radiations including several [alpha] particles, [beta] particles, and [gamma]-rays, does not lend itself to clear delineation of the biological effects of the [alpha] particles alone. Polonium-210, the terminal radionuclide of the radon decay series, is useful for this purpose because it has a relatively long shelf-life ([tau][sub 1/2] = 138 d), and it only emits a single 5.3 MeV [alpha] particle in its decay to stable [sup 206]Pb. Accordingly, it has been used extensively in radiobiological studies with incorporated radionuclides. The radionuclide [sup 210]Po is produced in a reactor from [sup 209]Bi. (Author).
Results of experimental investigation into radiation electromagnetic effect (REM) in samples of germanium crystals under approximately 40 MeV #alpha#-particle irradiation in a cyclotron are presented. A high level of excitation, volumetric character of generation of non-equilibrium carriers and formation of defects as well as the form of their spatial distribution are shown to result in some peculiarities of the EMF of the REM effect on the particle flux, fluence and sample parameters. Agreement of theoretical calculations, conducted with account of specificity of #alpha#-particle interaction with a crystal, and experimental data is obtained. It is revealed that the REM effect can be applied in obtaining data on spatial distribution of non-equilibrium carrier concentrations along the particle trajectory in the crystal.
The real parts of the optical model potentials for 104 MeV alpha-particle and 156 MeV "6Li ion scattering from "4"0,"4"8Ca are calculated in terms of folding model approaches. The validity of different procedures is tested by comparing the differential cross section predictions with experimental data measured with high angular accuracy. It is found that a refined folding potential accounting for density dependence of an effective nucleon-nucleon interaction is appropriate for alphaparticle scattering without any parameter adjustment. However, for "6Li ion scattering renormalization of the depth of the real potentials is necessary. (orig.).
Differential cross sections of the (#alpha#, t) reactions on "4"5Sc, "5"1V, and "5"9Co nuclei are measured in the 10-71 deg, 10-155 deg, and 10-171 deg angular ranges, respectively, with 27.2 MeV alphaparticles. The cross sections have also been calculated on the basis of the distorted wave theory. The possibility of an unambiguous choice of the optical potential for alphaparticles is discussed. The angular distribution calculations using several combinations of the optical potentials in the inlet and outlet channels of the reactions show that consistence between the calculations and the measurements is achieved (especially in angular range, less than 90 deg, if one of the potentials is chosen to be a sufficiently deep one.
This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targetedradiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide therapy and the various components and ...
There is an increasing interest in using radioisotopes of rare earth elements for internal radiotherapy and for imaging in nuclear medicine. {sup 177}Lu is one of the promising radionuclides. This article reports on the first measurements of the excitation function for the production of {sup 177}Lu with proton-beam energies up to 17 MeV on natural hafnium targets. The experimental cross sections for the reaction {sup nat}Hf(p,x){sup 177}Lu were obtained by the activation of a stacked-foil target and subsequent gamma spectrometry. Theoretical cross sections were calculated up to 35 MeV with the EMPIRE nuclear reaction model code. The measured and calculated cross sections were used for deriving the thick-target yields and for estimating the production of other nuclides than {sup 177}Lu. Measured production cross sections of {sup 175,176,177,178}Ta on the same target are also ...
There is an increasing interest in using radioisotopes of rare earth elements for internal radiotherapy and for imaging in nuclear medicine. "1"7"7Lu is one of the promising radionuclides. This article reports on the first measurements of the excitation function for the production of "1"7"7Lu with proton-beam energies up to 17 MeV on natural hafnium targets. The experimental cross sections for the reaction "n"a"tHf(p,x)"1"7"7Lu were obtained by the activation of a stacked-foil target and subsequent gamma spectrometry. Theoretical cross sections were calculated up to 35 MeV with the EMPIRE nuclear reaction model code. The measured and calculated cross sections were used for deriving the thick-target yields and for estimating the production of other nuclides than "1"7"7Lu. Measured production cross sections of "1"7"5","1"7"6","1"7"7","1"7"8Ta on the same target are also presented.
Tumor-targeted monoclonal antibodies (mAb) might be useful as diagnostic or therapeutic agents when linked to cytotoxic or imaging reagents. Our group is working to test this hypothesis by linking cytocidal and image-producing isotopes to mAb and testing the utility of the radioimmunoconjugates formed in animal model systems. Radioiodines were first employed for these purposes,but unfavorable nuclear properties (half-lives, #gamma#-ray and #beta#-particle energies) and chemical reactivity (deiodination in vivo) limit their utility. Labeling immunoproteins with metallic radionuclides offers more versatility in that the selection of potentially useful radiometals spans the periodic table.Of the metallic radionuclides with physical properties most suited for use with mAb in nuclear medicine, few are more available or desirable than those of bismuth ("2"1"2Bi) and lead ("2"0"3Pb, "2"1"2Pb), as listed in Table 1. "2"1"2Bi or "2"1"2Pb could serve as sources for highly ...
Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional ...
First results are presented from an analysis of data from the DRIFT-IIa and DRIFT-IIb directional dark matter detectors at Boulby Mine in which alphaparticle tracks were reconstructed and used to characterise detector performance--an important step towards optimising directional technology. The drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based on an analysis of naturally-occurring alpha-emitting background. The drift velocity in DRIFT-IIb was [57 +/- 1 (stat) +/- 3 (sys)] m/s determined by the analysis of alphaparticle tracks from a Po-210 source. 3D range reconstruction and energy spectra were used to identify alphaparticles from the decay of Rn-222, Po-218, Rn-220 and Po-216. This study found that (22 +/- 2)% of Po-218 progeny (from Rn-222 decay) are produced with no net charge in 40 Torr CS2. For Po-216 progeny (from Rn-220 ...
The energy spectra of energetic confined alphaparticles are being measured using the pellet charge exchange method [R. K. Fisher, J. S. Leffler, A. M. Howald, and P. B. Parks, Fusion Technol. 13, 536 (1988)]. The technique uses the dense ablation cloud surrounding an injected impurity pellet to neutralize a fraction of the incident alphaparticles, allowing them to escape from the plasma where their energy spectrum can be measured using a neutral particle analyzer. The signal calculations given in the above-mentioned reference disregarded the effects of the alphaparticles' helical Larmor orbits, which causes the alphas to make multiple passes through the cloud. Other effects such as electron ionization by plasma and ablation cloud electrons and the effect of the charge state composition of the cloud, were also neglected. This report considers these issues, ...
The experiment on the determination of the tensor polarization of the residual nucleus is described for the reaction "6Li (#alpha#, #alpha#') "6Li. It is based on the unique connection of polarization tensors t_l_m of the residual nucleus for the reaction (#alpha#, #alpha#') and the angular correlation function W (#omega#_1, #omega#_2) for #alpha#'-particle and decay product of this nucleus, where #omega#_1, #omega#_2 are motion directions of #alpha#'-particle and decay product. The angular correlations of #alpha#'-particle and deuteron are measured for the "6Li (#alpha#, #alpha#', d)"4He reaction on the 27.2 MeV #alpha#-particle beam. The recording system consists of six silicon detectors and provides the energy resolution about 0.8 MeV and the angular resolution #+-# 3 deg. The polarization tensors of the residual nucleus "6Li (2.185 MeV, 3"+) are determined as the result of measuring the angular ...
Optimization of radiation shielding for a medium energy accelerator with 60 MeV alpha ions is carried out using the cost-benefit approach. Cost optimum shield thicknesses are estimated for different operating conditions of the accelerator. (author). 5 refs, 1 tab.
Elastic scattering of 27.2 MeV #alpha# particles on "4"0Ca has been investigated. Differential cross sections have been measured in the angular range from 10 deg to 175 deg in the lab. system. The theoretical analysis has proceeded from the proposition that the results of a calculation based on the optical model in the range of small angles (less than 20 deg for "4"0Ca) are independent of parameters and shape of the potential employed. Elastic scattering of #alpha# particles at angles up to 50 deg has been calculated using three sets of the optical potential parameters in the energy range 23.37-28.92 MeV. In the range of small angles a rather similar behaviour of the calculated curves can be observed whereas in the range of medium and large angles these curves behave very differently. The success in the reproduction of the angular distributions for the entire energy range is indicative of the weak ...
New and elaborate techniques for alpha-particle autoradiography of thick specimens based on the plastic nuclear track detector CR-39 have been developed. These permit a full analysis of both trace element and microdistribution of alpha-active nuclides present. The important features of the techniques are: 1) reliable low level configuration down to 10/sup -15/ Ci g/sup -1/, 2) high resolution alpha-particle spectroscopy in CR-39, 3) determination of the absolute abundance of alpha active nuclides present in the specimen, 4) determination of the distribution of emission with height up to 30 microns above the surface of the autoradiograph, 5) the local determination of the radon diffusion coefficient in the specimen which is needed to calculate the activity levels of /sup 222/Rn and daughter nuclei, 6) the analysis of small and large clusters of alpha-particle activity recorded on the autoradiograph. These techniques are ...
The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target ...
Mass distribution in 28.5 MeV alphaparticle induced fission of "2"3"2Th has been determined using gamma spectrometric technique. The chain yields of 24 different fission products covering both symmetric and asymmetric mass divisions were determined. The mass distribution was found to be asymmetric with peak positions at mass numbers 96 and 136 respectively while the peak to valley ratio was 3.86. The results are compared with the available literature on 14 MeV neutron induced fission of "2"3"5U. (orig.).
Mass distribution in 28.5 MeV alphaparticle induced fission of {sup 232}Th has been determined using gamma spectrometric technique. The chain yields of 24 different fission products covering both symmetric and asymmetric mass divisions were determined. The mass distribution was found to be asymmetric with peak positions at mass numbers 96 and 136 respectively while the peak to valley ratio was 3.86. The results are compared with the available literature on 14 MeV neutron induced fission of {sup 235}U. (orig.).
Experimental differential cross sections for 104 MeV #alpha#-particle scattering have been analysed using a method recently proposed for model-independent analyses. Reliable values of isoscalar (0"+ -3"1"-) octupole transition rates in _5_0Ti, _5_2Cr and _2_0_8Pb are presented and compared with electromagnetic rates. (author).
Toroidal Alfven eigenmodes (TAE) destabilized by the pressure gradient of energetic alphaparticles may expel the alphaparticles before thermalization. TAE is important for tokamaks, and for helical systems (stellarators) as well. In CHS (compact helical system) TAE localized in the plasma core are destabilized when the plasma current is induced by co-injection of neutral beams. The observed TAE exhibits a ballooning nature. The internal structure of TAE was measured with a soft X-ray detector. The soft X-ray fluctuations level for TAE is too low to obtain the radial profiles of fluctuation intensities. (Tanaka, M.)
Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alphaparticles are a form of ionizing radiation and a typical 5-MeV alphaparticle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.
High energy ion backscattering analysis in combination with recently-developed resonance scattering analysis is described, with a stress on precise and quantitative oxygen analysis and its successful application to the characterization and quality estimation of high T_c oxide superconductors. Particularly, the present status of high energy ion backscattering analysis, the review of analytical results for YBa_2Cu_3O_7 _- _x, the estimation of composition and crystalline quality of (La_1 _- _xSr_x)_2CuO_4 by 7 MeV alphaparticle backscattering analysis are described.
Differential cross sections have been measured for the elastic and inelastic scattering of 104 MeV alpha-particles from /sup 90/,/sup 92/Zr. The experimental data are analyzed in terms of coupled channels on the basis of a flexible anharmonic vibrator model and using different parametrizations of the radial shape of the extended optical potential. The results favour the squared Saxon-Woods type for the real part. Additionally to a radial momentum analysis of the real potentials a semimicroscopic folding model has been invoked for extracting isoscalar quadrupole and hexadecapole transition rates.
Differential cross sections have been measured for the elastic and inelastic scattering of 104 MeV alpha-particles from "9"0,"9"2Zr. The experimental data are analyzed in terms of coupled channels on the basis of a flexible anharmonic vibrator model and using different parametrizations of the radial shape of the extended optical potential. The results favour the squared Saxon-Woods type for the real part. Additionally to a radial momentum analysis of the real potentials a semimicroscopic folding model has been invoked for extracting isoscalar quadrupole and hexadecapole transition rates. (orig.).
The treatment of locally advanced rectal cancer including timing and dosage of radiotherapy, degree of sphincter preservation with neoadjuvant radiotherapy, and short and long term effects of radiotherapy...Full Text Available
Precise measurements of alphaparticle counting efficiencies have been made using isotropic, infinitely thin alpha emitting sources placed in direct contact with a thin, end-window, gas flow proportional detector. Except for alphaparticle absorption in the window material, this geometry approaches 2#pi#, such that the only other variation in the response of the counter is from the random decay of the source. The data are fitted to the expected linear function of count rate versus window thickness and the resulting fitting parameters are used to calculate the counting efficiencies for a given thickness of window material. Counting efficiencies for 5.31, 6.06, and 8,78 MeV alphaparticles have been determined from sources of "2"1"0Po and the progeny of "2"1"2Pb. For the particular counter used, the counting efficiencies in counts per alpha and their respective ...
Purpose: This study presents a dosimetric optimization effort aiming to compare intensity-modulated (IM) X-rays and IM protons in 4 different orbital and paraorbital tumors. These are most challenging targets for standard radiotherapy due to their close relationship with the eyes and related structures. Methods and Materials: A primary orbital lymphoma, an optic nerve meningioma, a sphenoidal ridge meningioma protruding into the orbit, and a pediatric parameningeal paraorbital rhabdomyosarcoma were selected for the purpose of this study. Planning target volumes (PTVs) and organs at risk (OAR) were defined in each patient CT data set for each tumor site. IM X-ray and IM proton three-dimensional treatment plans were implemented. The following total tumor doses were prescribed: 30 Gy for the orbital lymphoma, 54 Gy for both meningiomas, and 50.4 Gy for the rhabdomyosarcoma case. Dose-volume histograms (DVHs) were obtained for ...
Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS patients and on a weekly ...
Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT approaches. Both CEBR and IMRT ...
Summation Copper-64 (T1/2?=?12.7 hours; ?+, 0.653?MeV [17.8 %]; ??, 0.579?MeV [38.4 %]) has decay characteristics that allow for positron emission tomography (PET) imaging and targetedradiotherapy of cancer. The well-established coordination chemistry of copper allows for its reaction with a wide variety of chelator systems that can potentially be linked to peptides and other biologically relevant small molecules, antibodies, proteins, and nanoparticles. The 12.7-hours half-life of 64Cu provides the flexibility to image both smaller molecules and larger, slower clearing proteins and nanoparticles. In a practical sense, the radionuclide or the 64Cu-radiopharmaceuticals can be easily shipped for PET imaging studies at sites remote to the production facility. Due to the versatility of 64Cu, ...
We have observed significant differences in the response to ionizing radiation of two closely related human cell lines, and now compare the effects on these lines of both low and intermediate LET radiation. Compared to TK6, WTK1 has an enhanced X-ray survival, and is also more resistant to cell killing by {alpha}-particles. The hprt locus is more mutable in WTK1 than in TK6 by both X-rays and {alpha}-particles. WTK1 is also more mutable by {alpha}-particles than by X-rays at the hprt locus. X-ray-induced mutation at the heterozygous tk locus in WTK1 is about 25 fold higher than in TK6, while {alpha}-particle-induced mutation is nearly 50 fold higher at this locus. Also, the slowly growing tk- mutants, which comprise the majority of spontaneous and X-ray-induced tk- mutants of TK6, were not induced significantly by {alpha}-particles. Previously, we showed that TK6 has a reduced ...
Radiotherapy has been reported to be of benefit in prolonging the survival of patients with cholangiocarcinoma. This study examined whether radiotherapy in addition to endoscopic stenting improved survival. The survival advantage of radiotherapy in those with a type II/III stricture is seen only in the first 10 months after diagnosis. The costs of radiotherapy and significantly increased time spent in hospital, however, raise doubts over its routine use in the management of non-resectable cholangiocarcinoma. (Author).
It is proposed to extract, independently of any nuclear model, the "4"0Ca matter density from an analysis of the elastic scattering of "1"6"6 MeV alphaparticles. The scattering is described using an optical potential whose real part is evaluated by folding the matter density with a nucleon-alpha interaction. Following the procedure proposed by Sick (Nucl. Phys. A; 218: 509 (1974)) and Phys. Lett.; 44B; 62 (1975)) for the analysis of electron scattering data, the density is represented by a sum of gaussians whose amplitudes are deduced in fitting, via a chi"2 minimization, the experimental cross section data. This method determines the envelope of densities for different parameters of gaussians: width, spacing. The envelope of the moments of these densities are presented and the root-mean-square radius is extracted. It is concluded that only the nuclear surface is well studied by the alphaparticle ...
Inelastic scattering of 180 MeV {pi}{sup +} and {pi}{sup {minus}} from {sup 52}Cr shows an angular distribution for the 2{sub 2}{sup +} state at 2.96 MeV that differs greatly from the usual {ital L} = 2 shapes for 2{sup +} states. This state is perhaps the only case from pion-inelastic scattering in which standard distorted-wave impulse approximation models (including multistep and single-step responses) fail to reproduce the measured angular distribution. Furthermore, this unique excitation has been shown to have the features expected of a seniority-four proton excitation yet the pion data show charge symmetry. While coupled-channel calculations are not able to reproduce the pion data, they do agree with the shape observed for 42 MeV {alpha} particle scattering to this state, but the magnitude of the {alpha} scattering data is not consistent with a collective model and known {gamma} ray deexcitations. Scattering to the first and third 2{sup +} ...
Inelastic scattering of 180 MeV #pi#"+ and #pi#"- from "5"2Cr shows an angular distribution for the 2_2"+ state at 2.96 MeV that differs greatly from the usual L = 2 shapes for 2"+ states. This state is perhaps the only case from pion-inelastic scattering in which standard distorted-wave impulse approximation models (including multistep and single-step responses) fail to reproduce the measured angular distribution. Furthermore, this unique excitation has been shown to have the features expected of a seniority-four proton excitation yet the pion data show charge symmetry. While coupled-channel calculations are not able to reproduce the pion data, they do agree with the shape observed for 42 MeV #alpha# particle scattering to this state, but the magnitude of the #alpha# scattering data is not consistent with a collective model and known #gamma# ray deexcitations. Scattering to the first and third 2"+ states of "5"2Cr with pions and ...
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be ...
A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will optimize delivery characteristics. The system will be capable of being sited in a ...
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available
The theory of ..cap alpha.. decay in first-order perturbation theory is presented. The theory is designed for a strongly deformed nucleus in an isomeric state which changes its deformation dynamically through decay from a very deformed to an almost spherical shape. It is shown that other channels are not coupled to the ..cap alpha.. channel in first-order perturbation theory. The collective degrees of freedom of the daughter nucleus are described by shape vibrational states, eigenstates of a Hamiltonian whose potential has two minima. The parent nucleus is described by dynamically coupling the vibrational degrees of freedom to the ..cap alpha..-particle motion and also taking rotations into account. The ..cap alpha.. particle is taken to be a point-like particle. The theory is applied to the ..cap alpha.. decay of the isomeric state of /sub 95//sup 242/Am.
The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)
The analysis of elastic and inelastic scattering of #alpha# particles with energy of 50 MeV by nuclei with mass numbers A=54-124 and of "3He particles by the nucleus "6"4Ni is given in the framework of the optical model. The parameters of multipole deformations for lower states are determined. The parameters for quadrupole and octupole deformations of the potential for the nucleus "1"1"2Sn are extracted, the values of the hexadecupole deformation #beta#_4 of the potential for nuclei "9"4Zr, "1"2"0","1"2"4Sn are found. Information is extracted on the ratio of deformation parameters for the neutron and proton components in lower collective states (2_1"+, 3_1"-) of nuclei with A=90-124.
Stage III and stage IV recovery have been investigated resistometrically following 6.1 MeV alpha-particle irradiation at 4.2 K. The activation energy associated with stage III shows a gradual increase from 0.35 +- 0.02 eV to 0.39 +- 0.02 eV. Stage IV (155 to 180 K) is associated with an activation energy of 0.46 +- 0.03 eV. The present results are compared with those obtained after electron and neutron irradiation. The stage III recovery kinetics are interpreted in terms of the Goesele-Seeger theory for interstitial migration in highly anisotropic hexagonal metals. Stage IV is ascribed to monovacancy migration. (author).
The present work is a research of the effect of helium on the microstructure, mechanical properties and fracture behaviors of a type 316 austenitic steel. Helium implantation was performed by 30-MeV #alpha#-particle injection on very small size specimens, using a cyclotron. Average helium content in a He-deposited region was up to 2000 appm He. In the case of 2000appm He implantation, intergranular fracture was sometimes observed on the helium deposited region after tensile test at room temperature. At elevated temperature test, however, this material showed the transition of fracture mode from transgranular-ductile fracture at 773K to intergranular fracture at 873. In the case of 500 appm He implantation, the transition of fracture mode was recognized at a temperature range of 873K to 973K. (author).
The effect of helium on the mechanical properties and fracture behaviors of a type 316 austenitic steel is presented. Helium implantation was performed by 30-MeV #alpha#-particle injection on very small, thin specimens, using a cyclotron accelerator. Average helium content in the He-deposited region was 50 to 2000 appm He. These specimens showed the transition of fracture mode from transgranular to intergranular fracture in elevated temperature tests. The transition temperature decreased with increase in the amount of implanted helium. For example, in the case of 2000 appm and 500 appm He implantation, the transition temperatures were between 773 and 873 K and 873 and 973 K, respectively. (orig.).
A LLX procedure for carrier-free separation of the radioisotopes, {sup 47}Sc, {sup 48}V and {sup 48},{sup 49},{sup 51}Cr, the 40 MeV {alpha}-particle activation products of titanium has been developed. Sequential separations of the radionuclides produced in the titanium matrix through the nuclear reactions ({alpha}, {alpha}p{chi}n), ({alpha}, p{chi}n) and {alpha}, ({chi}n) have been performed through LLX from aqueous H{sub 2}SO{sub 4} and HClO{sub 4} acid media using the liquid cation exchanger, HDEHP, as an extractant. Purity of the carrier-free radiotracers at different stages of their separations has been verified by {gamma}-ray spectrometry. (author).
Data from Monte Carlo transport codes are used to model radiobiological effects. We previously reported the Fourier analysis of ionization data generated by simulating a 500-keV proton traversing water. Here, we extend Fourier analysis to energy transfer data of another radiation type, a 14-MeV #alpha#-particle. A radiobiological model based on this frequency-domain analysis views cell as an information processing system . It lends itself naturally to traditional engineering analyses. One engineering principle-the output response of a linear system to random signal-is applied here to explain the fact that there is measurable difference in the magnitude of the biological effectiveness when a given biological system is irradiated with two different radiation types of the same Linear Energy Transfer (LET).
The phenomenon of radiation blistering by helium ion bombardment has been the subject of extensive studies in recent years because of its technological importance in thermonuclear fusion devices and reactors. However, the mechanism of radiation blistering is still not well understood. There are two different models of blister formation: the gas-pressure model and the lateral stress model. The former model is, however, supported by many experimental observations, the prominent one is that of Evans and Eyre who observed blisters appearing on the front and rear surfaces of a thin wedge-shaped molybdenum foil irradiated by helium ions. Their experiment also indicates that the thickness of the irradiated specimen could be important in affecting the characteristics of blisters. With this in view, we have studied the development of blisters in thin foils of tantalum by 30 MeV ..cap alpha..-particle bombardment.
The phenomenon of radiation blistering by helium ion bombardment has been the subject of extensive studies in recent years because of its technological importance in thermonuclear fusion devices and reactors. However, the mechanism of radiation blistering is still not well understood. There are two different models of blister formation: the gas-pressure model and the lateral stress model. The former model is, however, supported by many experimental observations, the prominent one is that of Evans and Eyre who observed blisters appearing on the front and rear surfaces of a thin wedge-shaped molybdenum foil irradiated by helium ions. Their experiment also indicates that the thickness of the irradiated specimen could be important in affecting the characteristics of blisters. With this in view, we have studied the development of blisters in thin foils of tantalum by 30 MeV #alpha#-particle bombardment. (orig.).
The simultaneous hydrogen and silicon atom densities in amorphous silicon, a-Si, films prepared by the glow discharge technique have been measured by 25 MeV #alpha#-particle elastic scattering. Integrated band intensities for the silicon-hydrogen stretching modes, #omega#_1sup(s) and #omega#_2sup(s) in the region 1800 to 2200 cm"-"1 were determined for the same freely supported films. A similar analysis has been carried out for the bands observed at 890, 840 and 640 cm"-_1. Effective oscillator strengths for the #omega#_1sup(s) and #omega#_2sup(s) modes in a-Si films have been estimated and compared with the current theories on the effect of the silicon matrix on the infrared absorption characteristics. (author).
The contribution of exchange processes (heavy stripping and substitution) into the amplitude of the 25-30 MeV #alpha#-particle elastic scattering by "1"2C and "4"0Ca nuclei is examined taking into account the distortion of plane waves of initial and finite particles. The eikonal approximation is used for accounting for distortions. The matrix elements of exchange processes are calculated. The results of calculations show that the Wronskian cutoff radii are close to those which have been obtained for calculation of exchange processes in the plane-wave approximation. The moduli of the values defining the contribution of exchange processes to the total S matrix are plotted. Also presented are Argand diagrams and angular distributions for both reactions. It has been established that the account for exchange processes improves the agreement of theoretical curves with the experiment in the whole range of angles, as compared with the optical model.
We have developed a low-temperature particle detector that uses a novel quasiparticle trapping mechanism to funnel athermal phonon energy from an 80 mg Ge absorber into a 1.6 mg doped Ge thermistor via a superconducting Al film. We report on pulse height spectra obtained at 320 mK by scanning a {sup 241}Am alpha source along the device, and show that up to 20% of the energy deposited in the Ge absorber by a 5.5 MeV alphaparticle interaction can be collected into a thermistor via quasiparticle trapping. We show that this device is sensitive to the position of an alphaparticle interaction in the Ge absorber for interaction distances of up to 5 mm from a quasiparticle trap.
Proton and alpha decay from the giant resonance region of {sup 28}Si excited with a 129 MeV alphaparticle beam has been measured in coincidence with inelastic alphaparticles detected at 0{degree}. The angular correlation data show the presence of decay from both {ital E}0 and {ital E}2 giant resonances. The {ital E}0 giant resonance decays primarily through the {alpha}{sub 0}, {alpha}{sub 1}, {ital p}{sub 0}, and {ital p}{sub 1,2} channels with the branching ratios 18{plus minus}6 %, 24{plus minus}8 %, 23{plus minus}9 %, and 18{plus minus}8 %, respectively. Substantial direct decay is observed.
Elastic scattering of 22 MeV alphaparticles by "2"3Na, sup(24-25-26)Mg, "2"7Al and "2"8Si has been measured between 24"0 and 174"0 lab. Partial angular distributions, from 120"0 to 174"0, were also measured at incident energies of 18.4 and 20.7 MeV for "2"4Mg, and 18.9 and 20.5 MeV for "2"8Si. The most striking feature of the data is the large angle behaviour: spin-zero nuclei display more pronounced backward oscillations and the cross section rises more steeply towards 180"0 for 4n nuclei than for the others. (Z.M.).
Formulae are obtained for the angular correlation function of inelastically scattered ..cap alpha.. particles and ..gamma.. quanta of a pure EL multipolarity, which are emitted by an excited nucleus, in the case of exchange processes, if distortions are introduced into the eikonal approximation. The matrix element of the exchange processes is considered as a coherent sum of contributions from two mechanisms: replacement and stripping of a heavy particle. Concrete calculations are performed for the reaction /sup 12/C(..cap alpha.., ..cap alpha..'..gamma..)/sup 12/C. The obtained results show that the developed formalism enables one to get an agreement between the theoretical angular correlation functions with the experimental data at reasonable values of the calculation parameters.
Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbed dose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbed dose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alphaparticle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired dose level.
The alphaparticle induced fission of {sup 209}Bi has been investigated for E{sub {alpha}} = 55.7 and 58.6 MeV using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The mass distributions have been found to be broad with a peak near mass 104. The charge distribution has been studied at the same particle energies. The fractional cumulative yields of {sup 97}Zr, {sup 99}Mo, {sup 101}Mo, {sup 112}Pd and {sup 117m}Cd have been determined using gamma ray spectrometry. The width of charge distribution is broad. (orig.).
The alphaparticle induced fission of "2"0"9Bi has been investigated for E_#alpha# = 55.7 and 58.6 MeV using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The mass distributions have been found to be broad with a peak near mass 104. The charge distribution has been studied at the same particle energies. The fractional cumulative yields of "9"7Zr, "9"9Mo, "1"0"1Mo, "1"1"2Pd and "1"1"7"mCd have been determined using gamma ray spectrometry. The width of charge distribution is broad. (orig.).
BackgroundThe use of fractionated stereotactic radiotherapy (fsrt) has evolved with technical advances in noninvasive immobilization, radiation delivery, and image guidance....Full Text Available
The challenges of lung cancer radiotherapy are intra/inter-fraction tumor/organ anatomy/motion changes and the need to spare surrounding critical structures. Evolving radiotherapy technologies, such...Full Text Available
Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure ...
Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT approaches. Both CEBR and IMRT ...
It has often been proposed that track diameter in etched detectors can be used for energy spectrometry. To test this proposition, the relationship between track diameter and energy of alphaparticles, in the range 0.1-5.5 MeV, incident on CR-39 was studied. Two sets of detectors were irradiated by a collimated normally-incident beam of {alpha}-particles of different energies, using an Am-241 source. Different foils of the first set were etched for variable lengths of time in such a way that, in each case, the etchant reached the end of the latent track. Foils in the second set were etched for a fixed 'short' time of 2 h, for all {alpha}-energies. The linear rate of energy loss as well as the residual range of {alpha}-particles was determined by using Henke and Benton's computer program. It is found that, for 'short' etching times, the track diameter mimics ...
Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.
The possibility of fabricating a superconductive vertex detector is discussed on the basis of a preliminary experiment. The experiment has shown that an indium strip 15 mm long, 20 ..mu..m wide and 0.1 ..mu..m thick is changed from the superconductive state to the normal state when struck by a single 5.4 MeV alphaparticle.
This research has two main goals; (1) to quantify mechanisms for radon entry into homes of different types and to determine the fraction of indoor radon attributable to each source and (2) to model and calculate the dose (and therefore alphaparticle fluence) to cells in the human and animal tracheobronchial tree that is pertinent to induction of bronchogenic carcinoma from inhaled radon daughters.
A coherent lidar system has been constructed for the measurement of alphaparticles in a burning plasma. The lidar system consists of a pulsed CO{sub 2} laser transmitter and a heterodyne receiver. The receiver local oscillator is a cw, sequence-band CO{sub 2} laser operating with a 63.23 GHz offset from the transmitter.
The linear/supralinear behaviour of the TL dose response in LiF:Mg,Ti (TLD-100) and its dependence on ionisation density is a fairly unique phenomenon which cannot be explained by conventional atomic 'conduction band/valence band' kinetic models. The Track Interaction Model (TIM) provides the microscopic framework which, when coupled with other appropriate physical mechanisms (spatial localisation of traps and recombination centres, competing centres, variations in the capture cross sections with temperature, etc.) can be used to describe all the dominant features of the TL supralinearity of LiF:Mg,Ti and similar TL systems. The unique feature of the TIM applied to alphaparticles is that it is an integral approach with only one free parameter, the average charge carrier migration distance in the luminescence recombination stage. Although the TIM provides a comprehensive description of the mechanisms underlying supralinearity ...
Toroidicity Alfven Eigenmodes (TAE) in ITER can be driven unstable by two groups of energetic particles, the 3.5 MeV {alpha}-particle fusion products and the tangentially injected 1MeV beam ions. Stability conditions are established using the perturbative NOVA/NOVA-K codes. A quasi-linear diffusion model is then used to assess the induced redistribution of energetic particles.
The document reports the main issues discussed during the first course-debate on quality controls in radiotherapy, held in Rome in December 3-4, 1998 and May 3-5 1999 in collaboration between the Istituto Superiore di Sanita' and the Istituto Regina Elena. The points considered critical to the quality assurance in radiotherapy by the participants are presented in relation to the total radiotherapy procedure.
The aim of this study is to compare the dosimetry results that are obtained by using Convolution, Superposition and Fast Superposition algorithms in Conventional Radiotherapy, Three-Dimensional Conformal...Full Text Available
Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging ...
{sup 188}Re is a {beta}{sup -} (Emax=2.12 MeV) and {gamma} (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, {sup 99m}Tc, molecules of hyaluronic acid (HA) have been labelled with {sup 188}Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm{sup 3} pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of {sup 188}Re and with C57 black mice injected with the {sup 188}Re-HA solution are presented. To increase the space resolution and to ...
This work describes an experimental verification of the two-photon dose calculation engines available on the Helax-TMS (version 6.1) commercial radiotherapy treatment planning system. The performance of the pencil beam convolution and the collapsed cone superposition algorithms was examined for 4, 6, 15 MV beams, under a range of clinically relevant irradiation geometries. Comparisons against measurements were carried out in terms of absolute dose, thus assessment of the accuracy of monitor unit (MU) calculations was also carried out. Results show that both algorithms agree with measurement to acceptable tolerance levels in most cases in homogeneous water-equivalent media irradiated under full scatter conditions. The collapsed cone algorithm slightly overestimates the penumbra width and this is mainly due to discretization effects of the fluence matrix. The accuracy of this algorithm strongly depends on the resolution of the patient density matrix. It is ...
Purpose/Objective. Daily Cone-beam computed tomography (CBCT) in room imaging is used to determine tumour shrinkage during a full radiotherapy (RT) course. In addition, relative interfractional tumour and lymph node motion is determined for each RT fraction. Material and methods. From November 2009 to March 2010, 20 consecutive lung cancer patients (14 NSCLC, 6 SCLC) were followed with daily CBCT during RT. The gross tumour volume for lung tumour (GTV-t) was visible in all daily CBCT scans and was delineated at the beginning, at the tenth and the 20th fraction, and at the end of treatment. Whenever visible, the gross tumour volume for lymph nodes (GTV-n) was also delineated. The GTV-t and GTV-n volumes were determined. All patients were setup according to an online bony anatomy match. Retrospectively, matching based on the internal target volume (ITV), the GTV-t or the GTV-n was performed. Results. In eight patients, we observed a significant ...
Purpose: An inverse treatment planning algorithm for tomotherapy is described. Methods and Materials: The algorithm iteratively computes a set of nonnegative beam intensity profiles that minimizes the least-squares residual dose defined in the target and selected normal tissue regions of interest. At each iteration the residual dose distribution is transformed into a set of residual beam profiles using an inversion method derived from filtered backprojection image reconstruction theory. These 'residual' profiles are used to correct the current beam profile estimates resulting in new profile estimates. Adaptive filtering is incorporated into the inversion model so that the gross structure of the dose distribution is optimized during initial iterations of the algorithm, and the fine structure corresponding to edges is obtained at later iterations. A three dimensional, kernel based, convolution/superposition dose model is used to compute dose during each iteration. ...
Purpose: To develop an accurate, fast, and robust algorithm for registering portal and computed tomographic (CT) images for radiotherapy using a combination of sparse and dense field data that complement each other. Methods and Materials: Gradient Feature Weighted Minimax (GFW Minimax) method was developed to register multiple portal images to three-dimensional CT images. Its performance was compared with that of three others: Minimax, Mutual Information, and Gilhuijs' method. Phantom and prostate cancer patient images were used. Effects of registration errors on tumor control probability (TCP) and normal tissue complication probability (NTCP) were investigated as a relative measure. Results: Registration of four portals to CTs resulted in 30% lower error when compared with registration with two portals. Computation time increased by nearly 50%. GFW Minimax performed the best, followed by Gilhuijs' method, the Minimax method, and Mutual Information. Conclusions: ...
Anticancer drug thyotepa (10 mg/ kg) hormonal compound thyroxine (40 mg / kg) and D3 vitamin (30,000 IU / kg) have been administrated simply or associated to Wistar rats bearing Walker carcinosarcoma. The chromatin (the complex of DNA and proteins from nuclei) has been extracted from Walker tumor and submitted to fast neutron beams produced by deuterons (13 MeV) on thick Be target at an IPNE U-120 Cyclotron, in doses of 5-100 Gy. Thermal transition of chromatin fluorescence intensity of chromatin-ethidium bromide complexes and intrinsic fluorescence of chromatin have been analysed. Association of thiotepa with thyroxine and D3 vitamin produced a diminution of chromatin lesions induced by the cytostatic. Thus in the effects of fast neutrons radiolysis in chromatin significant differences occurred. These results could help to improve the methodology of associated chemotherapy-radiotherapy in clinical applications. (author).
Radiotherapy with high-energy carbon ion beams can be more advantageous compared to photons because of better physical dose distribution and higher biological efficiency in tumour cell sterilization. Despite enhanced normal tissue sparing, damage incurred by normal cells at the beam entrance is unavoidable and may affect the progeny of surviving cells in the form of inheritable cytogenetic alterations. Furthermore, the quality of the beam along the Bragg curve is modified by nuclear fragmentation of projectile and target nuclei in the body. We present an experimental approach based on the use of a polymethylmethacrylate (PMMA) phantom that allows the simultaneous exposure to a particle beam of several biological samples positioned at various depths along the beam path. The device was used to measure the biological effectiveness of a 60 MeV/amu carbon-ion beam at inducing chromosomal aberrations in G{sub 0}-human peripheral blood lymphocytes. ...
Background and purpose: Local treatment for non-metastatic Ewing's sarcoma family tumors (ESFTs) is controversial. Results achieved in a single institution in patients with ESFT of the humerus are presented. Materials and methods: Patients treated between 1983 and 2000 for ESFT of the humerus were included. The impact of local treatment (surgery, radiotherapy or both) on outcome was assessed. Results: 55 patients: 34 males (62%); 21 females (38%); mean age: 17.9 (range: 3-40). Local treatment: surgery in 27 patients (49%), radiotherapy in 17 (31%) and surgery followed by radiotherapy in 11 (20%). After a mean follow-up of 15 years (range: 7-25 years), 27 patients (49%) remained continuously disease free, 27 (49%) relapsed and one died of chemotherapy toxicity. The local recurrence rate was 13% overall: 18% (3/17) after radiotherapy, 7% (2/27) after surgery and 19% (2/11) after surgery followed by ...
The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as {alpha}-particle detector and as absorber decreasing the energy of {alpha}-particles. The uncertainties of implanted {sup 210}Pb measurements by two- and three-layer detectors are assessed in dependence on surface {sup 210}Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from {sup 210}Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached {sup 218}Po and air exchange rate. It is demonstrated that with the use of additional information on surface to volume room ...
The T/sub c/ behavior of vapor-deposited Nb_3Ge and Nb_3Sn is examined as a function of low-fluence alpha-particle irradiation. It is found that for Nb_3Sn with rho_0approx.15 #mu##OMEGA#-cm the T/sub c/ is insensitive to low doses of radiation, whereas Nb_3Ge with rho_0approx.50 #mu##OMEGA#-cm has its T/sub c/ depressed immediately with irradiation. It is suggested that the T/sub c/ behavior of A-15 superconductors in the regime of small dose is strongly influenced by the initial state of the sample. Furthermore, it is argued that the behavior of the T/sub c/ with dose can be qualitatively explained by considering a sharp structure in the density of states N(E), the smearing of which by defects leads to a depression in T/sub c/.
Technique, allowing to investigate straggling zone (full braking) from high-energy charged particles in detail, is described. Experimental results on investigation of efective structure, created in polycrystalline molybdenum (99.97%) within 29 MeV alpha-particles straggling zone for fluences from 3.8x10"1"9 up to 3.7x10"2"1 #alpha#/m"2 by methods of microhardness (H_#mu#, X-ray structural analysis (#DELTA#a/a) and transparent electron microscopy (TEM), are presented. It is determined, that for doses from 3.8x10"2"0 #alpha#/m"2 and higher, at #approx#6 MeV energy, molybdenum ''softening'' is observed, H_#mu# curve within straggling zone is well described by alloyage calculated profile. #DELTA#a/a measurements within straggling zone are well described by damage profile. TEM-investigations have shown the developed defective structure even within molybdenum ''softening'' range.
Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alphaparticles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alphaparticle interactions.
Precisely measured differential cross sections for elastic and inelastic scattering from 104 MeV alpha-particles by _4_8Ca, _5_0Ti and _5_2Cr are reported. The analyses aim primarily at the determination of strength, radial shapes and deformation of the scattering potentials, looking for isotonic differences of N=28 isotones. The mean square radii of the (real) potentials are discussed in terms of mean square radius differences of the matter distributions. The isoscalar transition rates derived by coupled channel analyses of the measured cross sections are compared with electromagnetic rates. In addition to the analyses on the basis of a slightly generalized extended optical model a semi-microscopic deformed folding model has been applied, using a density-dependent effective alpha-bound nucleon interaction. Though an excellent description of the data over the full angular range is obtained the resulting values of the deformation parameters appear to be not ...
Precisely measured differential cross sections for elastic and inelastic scattering from 104 MeV alpha-particles by /sup 48/Ca, /sup 50/Ti and /sup 52/Cr are reported. The analyses aim primarily at the determination of strength, radial shapes and deformation of the scattering potentials, looking for isotonic differences of N=28 isotones. The mean square radii of the (real) potentials are discussed in terms of mean square radius differences of the matter distributions. The isoscalar transition rates derived by coupled channel analyses of the measured cross sections are compared with electromagnetic rates. In addition to the analyses on the basis of a slightly generalized extended optical model a semi-microscopic deformed folding model has been applied, using a density-dependent effective alpha-bound nucleon interaction. Though an excellent description of the data over the full angular range is obtained the resulting values of the deformation parameters appear to be ...
Monte-Carlo simulations of 2-MeV #alpha#-particle channeling in Si_1_-_xSn_x alloys with 0#<=#x#<=#1 have been performed. The simulations are compared with measured channeling-angular scans for strained Si_0_._9_5Sn_0_._0_5 layers grown by molecular beam epitaxy (MBE). Agreement between simulated and measured angular scans can only be achieved if we assume a deviation of the crystal structure from the ideal one. This deviation can be attributed to a mosaic structure in the films and to an atomic-scale distortion of the crystal lattice due to an expected difference in the bond lengths between the Si-Si, Si-Sn and Sn-Sn atoms (such a difference in bond lengths has been observed in the epitaxial Si_1_-_xGe_x system). The contributions from both of these imperfections are estimated and discussed.
Minority-carrier lifetime damage coefficients for 1 MeV electron, 3 MeV proton, and 6 MeV alphaparticle irradiation of n-type (4.5{times}10{sup 15} and 1.3{times}10{sup 17}cm{sup {minus}3}) and p-type (2.5{times}10{sup 17}cm{sup {minus}3}) InP have been measured using time-resolved photoluminescence. These values are relatively insensitive to carrier type and show a slight increase with increasing carrier concentration. Evidence of comparable electron and hole capture lifetimes is found for the dominant recombination defect. The effect of 3 MeV proton and 6 MeV alphaparticles relative to 1 MeV electrons is an increase in the lifetime damage coefficient by factors of about 10{sup 4} and 10{sup 5}, respectively. {copyright} {ital 1997 American Institute of Physics.}
Structural variations in 39-MeV alpha-particle irradiated (Tsub(irr) = 60 deg C) polycrystalline molybdenum during post-irradiation annealing were studied by X-ray and TEM methods. Despite the high density of irradiation induced defects in the structure of the specimen X-ray measurements showed zero relative lattice parameter change after an irradiation dose of 1.1 x 10"-_2 dpa. However, during the annealing #delta#a/a was changed in the positive range, exhibiting two peaks - at 100 and 300 deg C - whereas the damage structure detected by TEM indicated no changes. Analysis of the results leads to the conclusion that in the range 100 to 250 deg C migration of isolated vacancies and their annihilation at interstitial clusters as well as possible formation of new vacancy clusters occur. The second peak on the #delta#a/a temperature dependence curve is related to the transformation (probably, thermal disintegration) of vacancy clusters formed at energetic displacement ...
Differential cross sections of elastic scattering of 104 MeV #alpha# particles from "2"0"4,"2"0"6,"2"0"8Pb have been measured with high angular accuracy. The analyses are based on a folding model treating the proton and neutron distributions independently. The proton distributions were taken from precise electron scattering results. The neutron distributions were parametrized by a modified Gaussian the parametrers of which were varied in order to fit the experimental cross sections. The resulting rms radii of the neutron distributions exceed the rms radii of the proton distributions by #DELTA#r=0.22 +- 0.09 fm for "2"0"4Pb, #DELTA#r = 0.19 +- 0.09 fm for "2"0"6Pb, and #DELTA#r = 0.30 +- 0.07 fm for "2"0"8Pb.
In the present investigation the performance of digital data acquisition (DA) and analogue data acquisition (AA) systems are compared in neutron-induced fission experiments. The DA results are practically identical to the AA results in terms of angular-, energy- and mass-resolution, and both compare very well with literature data. However, major advantages were found with the digital techniques. DA allows for a very efficient #alpha#-particle pile-up correction. This is important when considering the accurate measurement of fission-fragment characteristics of highly #alpha#-active actinide isotopes relevant for the safe operation of Generation IV reactors and the successful reduction of long-lived radioactive nuclear waste. In case of a strong #alpha#-emitter, when applying the #alpha#-particle pile-up correction, the peak-to-valley ratio of the energy distribution was significantly improved. In addition, DA offers a very flexible expanded ...
The "2"0 "2"1 "2"2Ne("6Li, d)"2"4 "2"5 "2"6Mg reactions have been studied at a bombarding energy of 32 MeV. Alphaparticle spectroscopic strengths have been extracted for several low-lying levels by a finite-range distorted wave analysis. These are compared with theoretical predictions. The agreement is good both for relative strengths to different levels within a nucleus and for ground-state strengths relative to the "1"6O("6Li, d) result. Strengths calculated using eigenfunctions determined in large shell-model computations agree well with pure symmetry SU(3) predictions. The "2"1Ne("6Li, d) angular distributions for transitions to the ground-state band of "2"5Mg are characterized by the lower of the two L-transfers allowed for populating each level. For the 3"+(5.24 MeV) unnatural parity level in "2"4Mg, a two-step calculation gives a better account of the data than does a compound nuclear calculation. (Auth.).
The general usefulness of neutron activation analysis (NAA) for samples containing the platinum group elements (PGE) and Au, either as major or trace constituents, is discussed. Charged particle activation is shown to be a viable or complementary alternative. Proton (6-10 MeV) and alphaparticle (9-15 MeV) beams, produced in a tandem Van de Graaff accelerator, have been established to be the most effective choice. By taking advantage of the Coulomb barrier effect and the fact that many charged particle induced reactions have relatively large threshold values, the same instrumental technique can be applied, with minor modifications, to a wide range of materials.
The general usefulness of neutron activation analysis (NAA) for samples containing the platinum group elements and Au, either as major or trace constituents, is discussed. Charged particle activation is shown to be a viable or complementary alternative. Proton (6-10 MeV) and alphaparticle (9-15 MeV) beams, produced in a Tandem van de Graaff accelerator, have been established to be the most effective choice. By taking advantage of the Coulomb barrier effect and the fact that many charged particle induced reactions have relatively large threshold values, the same instrumental technique can be applied, with minor modifications, to a wide range of materials.
The platinum-silicide layer was investigated as the anode contact of a high-power P-i-N diode. The thermal stability at 700 deg. C was found sufficient for the purpose of Pt in-diffusion from the platinum-silicide layer into the volume. The diffusion, which was controlled using the radiation defects resulting from the 10 MeV alphaparticle irradiation, represents a new local lifetime control in the float zone silicon with very low-leakage current, while keeping the benefits of traditional approaches.
The "2H(#alpha#,p#alpha#)n reaction was investigated in a kinematically complete experiment with a #alpha#-beam at energy 27.2 MeV.The "5He excited state was observed and its parameters were determinate.Coincidence spectra were fitted by contribution of sequential decay through the "5He ground and excited states.The best agreement with the data was obtained assuming the following "5He excited state parameters: E_a_n=2.8 MeV #GAMMA#=2.5 MeV.
A discussion of some of the difficulties with previous analyses of the resistivity of A-15 compounds is given. Precise high-temperature data on ..cap alpha..-particle- and electron-damaged Nb/sub 3/Ge and Nb/sub 3/Sn samples with different defect concentrations are presented here and analyzed in a simple way with use of a phenomenological model based on the idea that the ideal resistivity must approach some limiting value in the regime where the mean free path becomes comparable to the interatomic spacing.
A method is proposed for the quantitative high-temperature isolation of /sup 111/In from silver irradiated by ..cap alpha..-particles into a gas phase containing a mixture of HCl and H/sub 2/O with a total pressure of about 3 Pa for these gases. It is shown that the indium evolved into the gas phase probably occurs in the form of at least three compounds, viz.., the trichloride, monochloride, and oxychloride, which have adsorption temperatures on quartz of around 385, 475, and 655 K, respectively. All these compounds are readily washed from the surface of quartz apparatus by a weak (0.05 M) solution of hydrochloric acid.
It is discussed here how trustworthy predictions of etched track parameters in nuclear track detection technique can be made? Problems involved in doing so are described along with discussion about their possible solutions. Arguments are presented using 5.2 MeV alphaparticle track etching experiments with CR-39 detector and corresponding calculations using computer programs TRACK{sub V}ISION and TRACK{sub T}EST. Experimental and computational results in the present paper are useful for further basic research and technology applications of solid state nuclear track detection technique.
Neon 19, a 17-second positron-emitting radioelement, is produced continously by 23 MeV alphaparticle bombardment of oxygen. For a 12 ..mu..A particle current the method of preparation described delivers 14 mCi of neon 19 per min to the functional exploration room. The radiochemically pure radioactive gas is diluted in air and breathed continously by the patient lying under a positron tomographic camera. The regional lung ventilation distribution is obtained on 2 cm thick sections of organ with a transverse resolution of 17 mm. Quantification of the ventilation output per unit lung volume is contemplated.
Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).
The mass and energy distributions for low-energy p- and alpha-particle induced fission of "1"8"7","1"8"8Ir and "1"9"5Au and "3He-induced fission of sufficiently heated "1"8"8Ir and "1"9"4Au have been measured with use of fast spectrometer of complementary fragments. From Au to Ir, the shape of the mass distributions undergoes substantial changes related to specific dependence of the saddle shell corrections on A and Z fissioning nuclei. The results are compared with theoretical predictions.
The effects of {alpha} particle irradiation on a passive film formed on a 304 type stainless steel are studied in situ. The experimental arrangement minimizes the radiolysis effects due to the electrolyte. Under irradiation, a modification of the electronic structure of the oxide layers is revealed by photo-electrochemistry and impedance measurements. The influence of irradiation on the corrosion resistance of the passive film is investigated. Comparing the rest potential and the breakdown potential respectively under and without irradiation, a drop in the passivity range under irradiation is shown. this is interpreted as a decrease in the corrosion resistance. (author).
The effects of #alpha# particle irradiation on a passive film formed on a 304 type stainless steel are studied in situ. The experimental arrangement minimizes the radiolysis effects due to the electrolyte. Under irradiation, a modification of the electronic structure of the oxide layers is revealed by photo-electrochemistry and impedance measurements. The influence of irradiation on the corrosion resistance of the passive film is investigated. Comparing the rest potential and the breakdown potential respectively under and without irradiation, a drop in the passivity range under irradiation is shown. this is interpreted as a decrease in the corrosion resistance. (author).
Characterization of high temperature superconducting film and bulk samples has been carried out using 2 MeV [alpha]-particle Rutherford backscattering, 2.4 MeV proton elastic scattering, 2.4 MeV proton-induced x-ray emission, 9 MeV proton induced [gamma]-ray emission and 100 MeV iodine elastic recoil detection analysis techniques. The objective was to compare different ion beam based techniques for: (i) compositional analysis; and (ii) consistency of the results obtained for samples prepared using similar preparation methodology. (author).
Angular distributions for the elastic and inelastic scattering of /sup 12/C at 80 MeV by /sup 88/Sr and of /sup 7/Li at 36, 42 and 48 MeV by /sup 54/Fe have been analysed. The optical potentials of /sup 12/C and /sup 7/Li ions are calculated in terms of the alpha-particle and triton optical potentials. Coupled-channels calculations using these potentials are performed. Good fits to the experimental data and the phenomenological calculations are obtained for /sup 12/C projectiles.
Nucleosynthesis and energy production in stellar environments depend critically on nuclear reaction cross sections. Reactions induced by alphaparticles are important in the helium burning stage of stars, novae, and supernovae events. They involve light to medium weight nuclei up to about Z=32, and center-of-mass energies up to about 20 MeV. We are working on a project to compile and evaluate cross section data for alpha-induced reactions. These data will eventually be used to derive #alpha#-nucleus potential parameters. (author)
Alphaparticles, tritons, deuterons and protons accompanying /sup 252/Cf fission were registered in coincidence with both fission fragments by means of a system containing two-dimensional position-sensitive silicon detectors. Angular distributions, kinetic energy spectra of light charged particles as well as mass distributions of fission fragments in coincidence with light charged particles were measured. The experimental results are compared with some theoretical models.
The detection efficiency of #alpha# particles of "2"1"4Po 7.69 MeV and "2"1"8Po 6.00 MeV in measuring radon daughters were determined through the data which were measured with long-lived #alpha# standard source and radon daughter standard source and with curve-fitting method of general formulation. The indeterminacy was #<=#2.5% and #<=#2.7% respectively. Their ranges in filter membrane were also determined, and the effect of the indeterminacy on the self-absorption factors was #<=#1.3%.
A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alphaparticles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).
OBJECTIVE: To evaluate prospectively the efficacy of a single fraction of high-dose radiotherapy in patients with Kaposi's sarcoma. PATIENTS: Between 1994 and 2004, 47 patients with Kaposi's sarcoma...Full Text Available
SummaryRadiotherapy is used commonly in the treatment of gynecologic malignancies. Many patients experience emotional distress prior to the initiation of radiotherapy, during...Full Text Available
The looming potential of deformable alignment tools to play an integral role in adaptive radiotherapy suggests a need for objective assessment of these complex algorithms. Previous studies in this area...Full Text Available
Intensity modulated radiotherapy (IMRT) is widely used in clinical applications in developed countries, for the treatment of malignant and non-malignant diseases. This technique uses multiple radiation...Full Text Available
IntroductionRadiotherapy outcomes might be further improved by a greater understanding of the individual variations in normal tissue reactions that determine tolerance. Most published...Full Text Available
In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available
The offline adaptive radiotherapy (ART) has been used to effectively correct and compensate the prostate motion and reduce the required margin. The efficacy depends on the characteristics of...Full Text Available
Track analysis of medium energy #alpha# particle trajectories recorded in fine grain nuclear emulsion submitted to specific intensifying treatments led to the observation of strong ionizing events (SIE) sticking out of the primary's track core. Preliminary determinations showed that the number of SIEs increases with the primary's energy, and that their production is of more than one order of magnitude higher than the number of Rutherford recoils. The presence of SIEs on monoenergetic #alpha# tracks also has a significant influence on the measured range distribution, which, expressed in terms of energy loss, results in a mean contribution to the total energy loss of far reaching (SIEs (radial spread >= 0.458 #mu#m) of proportional 25 keV per 13.6 MeV #alpha# particle, instead of 0.75 keV in the case where only the Rutherford interactions are taken into account. Measurements carried out in detectors ...
Introduction: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. Methods: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the signal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. Results: The signal- and contrast-to-noise ratios were significantly (P<0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 and 24 of 25 lesions of Flash and Turbo-Flash images, ...
The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (I.M.R.T.) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photon therapy treatment, external control could be very tedious and time consuming. Therefore, innovations are needed for in vivo dosimetry to provide ergonomic and efficient ...
The cross section and activity profile of different radioisotopes produced by #alpha#-induced nuclear reaction on natural zirconium, have been obtained by stacked foil activation using 40 MeV #alpha#-particles from Variable Energy Cyclotron (VEC) machine at Calcutta. The activity profile would be used to study the surface loss of zircaloy materials of engineering components by thin layer activation (TLA) technique. Generally, isotopes with suitable #gamma#-rays and long half-lives are the most useful in TLA technique, e.g., "9"2Nb, "9"5"gNb and "9"5Zr. (author). 2 refs., 1 tab.
In April and May of 1999 the Berkeley Gas-filled Separator was used to search for the production and decay of element 118 from the {sup 86}Kr + {sup 208}Pb reaction, according to Smolanczuk's predictions of relatively large production rates. Three decay chains, each consisting of an implanted heavy ion, followed by a rapid (ms) succession of high-energy (>10 MeV) alpha-particle decays were detected. These chains are consistent with the production and decay of element 118 with mass number 293. These results a) show experimental evidence for the existence of shell-stabilized superheavy elements, b) provide experimental values for refinement of nuclear mass models in the superheavy element region, and, most importantly, c) present a new' reaction pathway for the production of superheavy elements. (author)
Experiments have been carried out in water at 355 C to study transport of oxygen and hydrogen (as deuterium) in growing corrosion films. Composition of the films was also examined in 2.9 Mev and 3.9 Mev /alpha/-particle backscattering experiments. Corrosion occurs predominantly by oxygen diffusion through the film via grain boundary or similar short circuit diffusion paths, to form fresh oxide at the oxide metal interface. Increasing grain size within thick pre-breakaway films contributes to a decrease in diffusivity. The rate transition results from the generation of new diffusion pathways in previously protective oxide. Unexpectedly high concentrations of deuterium were observed. 26 refs.
Strain embrittlement in Ti base alloys during tensile testing was investigated. Results show that in an #alpha#-#beta# titanium alloy the local activity of H in alpha phase (#alpha#/sub H//sup #alpha#) increases and activity of H in beta phase (#alpha#/sub H//sup #beta#) decreases as the equiaxed #alpha# particle size decreases at constant volume fraction of phases. Thus with decreasing particle size there would be a tendency for H to move from #alpha# to #beta#, decreasing the H content of #alpha#. Also whether H tended to move from #beta# to #alpha# or from #alpha# interiors to the #alpha#-#beta# interface this tendency would be reduced by surface tension effects, making the alloy less susceptible to embrittlement.
In this paper we discuss a number of astrophysical environments and how improved nuclear data could facilitate a better understanding of them. One area of interest includes proton and alpha-particle reactions with unstable nuclei which are necessary for understanding the nucleosynthesis and energy generation in hot hydrogen-burning environments. Efforts underway at LLNL and elsewhere to develop the technology for the measurement of these reaction rates are discussed. Heavy-element nucleosynthesis in the late stages of red-giant stars and supernovae requires a complete network of neutron capture rates and beta-decay rates for nuclei near and far from stability. Experimental and theoretical efforts at LLNL to supply the input data and to model the nucleosynthetic environments will be outlined. Suggestions are made as to which nuclear data are most critical for the various scenarios. 42 refs., 11 figs., 1 tab.
Picosecond charge-collection transients measured for GaAs/AlGaAs HBTs following 3.0 MeV [alpha]-particle and 620 nm picosecond laser excitation reveal charge-collection efficiencies up to twenty-eight times smaller than for GaAs MESFETs, with [approximately]90% of the charge collected within 75 ps of the ionizing event. The small charge-collection efficiency of the HBTs is a consequence of the ultrafast charge-collection dynamics in these devices. The authors show that picosecond laser excitation reproduces nicely the ion-induced transients, providing a valuable tool for the investigation of charge-collection and SEU phenomena in these devices.
A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.
The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.
The neutron-induced fission cross-section of {sup 233}U has been measured at the CERN n-TOF facility relative to the standard fission cross-section of {sup 235}U between 0.5 and 20MeV. The experiment was performed with a fast ionization chamber for the detection of the fission fragments and to discriminate against {alpha} -particles from the natural radioactivity of the samples. The high instantaneous flux and the low background of the n-TOF facility result in data with uncertainties of {approx} 3%, which were found in good agreement with previous experiments. The high quality of the present results allows to improve the evaluation of the {sup 233}U (n,f) cross-section and, consequently, the design of energy systems based on the Th/U cycle. (orig.)
We compare the effect of isotropic point defects vis a vis extended defects on the inter and intra grain properties of superconducting MgB{sub 2} thin films. In a recent paper Gandikota et al. [Appl. Phys. Lett. 86 (2005) 012508] reported that after 200 MeV {alpha} particle irradiation intergrain connectivity remains unaffected. Our results on the contrary indicate that connectivity does depend on irradiation dose and type of ions used. We ascertain that extended defects alter the {sigma} band properties of this two-band superconductor more effectively than the point defects. The improvement in upper critical field and critical current density is intricately related to the type and density of defects created.
Neutron-induced soft error rates (SER`s) of subhalf-micron CMOS SRAM and Latch circuits were studied both experimentally and analytically to investigate cosmic ray neutron-induced soft errors (SE`s). Because the neutron beam used in the measurement has an energy spectrum similar to that of sea-level atmospheric neutrons, the SER data corresponds to those induced by cosmic ray neutrons. The {alpha}-particle induced SER`s were also measured for comparison with the neutron-induced SER`s. Neutron-induced SE`s occurred in both circuits. On the other hand, {alpha}-induced SE`s occurred in SRAM, but not in the Latch circuit. The measured SER`s agreed with simulated results. The authors discussed the significance of how cosmic ray neutrons affects CMOS circuits at ground level.
The chain yields of 30 fission products were determined in 38 MeV {alpha}-particle induced fission of {sup 232}Th. The mass yield curve was found to be primarily asymmtric with a peak to valley (p/v) ratio of 3.5. A small peak has also been observed in the symmetric region. The observed p/v ratio has been resolved into the p/v ratios of the individual mass distributions of the possible fissioning isotopes of uranium formed as a result of multichance fission. An attempt has been made to explain the p/v ratios thus obtained in the light of the available excitation energy in the system. (orig.).
Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.
We consider low-energy nucleons at next-to-next-to-leading order in lattice chiral effective field theory. Three-body interactions first appear at this order, and we discuss several methods for determining three-body interaction coefficients on the lattice. We compute the energy of the triton and low-energy neutron-deuteron scattering phase shifts in the spin-doublet and spin-quartet channels using Luescher's finite-volume method. In the four-nucleon system we calculate the energy of the {alpha}-particle using auxiliary fields and projection Monte Carlo. (orig.)
During helium beam fuelling experiments in JET, distinctive anisotropic features have been observed in the velocity distribution function describing both fast and thermal alphaparticle populations. During the initial fuelling phase the central helium ion temperature observed perpendicular to the magnetic field is higher than the central electron temperature, while the central helium ion temperature observed parallel to the magnetic field is lower than or equal to the central electron temperature. In order to verify temperature measurements of both perpendicular and parallel lines of sight, other independent methods of deducing the ion temperature are investigated: deuterium ion temperature, deuterium density, comparison with neutron rates and profiles (influence of a possible metastable population of helium). 6 refs., 7 figs.
Specimen damage and element loss induced by 3 MeV proton and 2 MeV alphaparticle bombardment of thin sections of freeze-dried kidney tissue and embedding medium have been studied. Yields of ions scattered from H and C, and characteristic X-rays were measured versus accumulated charge, for curent densities in the range from 8x10{sup -15} to 1.1x10{sup -11} A/{mu}m{sup 2}. Structural damage, dissolouration and loss of S, Cl, C and H have been observed. Implications of this study for ion beam microanalysis of biological tissues are discussed with particular reference to the results for H loss. (orig.).
We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alphaparticle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alphaparticles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alphaparticles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
The alpha-particle confinement of future D-T experiments at JET can be severely degraded by Global Alfven Eigenmodes (AE). Scenarios for the excitation of Alfven Eigenmodes in usual (e.g. D-D) plasmas are proposed, which provide a MHD diagnostic and allow the study of the transport of super-Alfvenic ions. Active studies with separate control of TAE amplitude and energetic particle destabilization, measuring the plasma response, give more information than passive studies, in particular concerning the damping mechanisms. The TAE excitation can be achieved by means of the saddle coil and the ICRH antenna. The experimental method is introduced together with a theoretical model for RF excitation. (authors). 6 refs., 3 figs.
Dose dependences of conductivity at a temperature of 78 K for InSb and InAs single crystals under reactor fast neutron, 50 MeV proton and 80 MeV alphaparticle irradiation up to fluence of 10{sup 17} cm{sup -2} are considered. Special attention is given to non-trivial, but little known semi-conductor characteristics in terms of {sigma}(F) dependence at large fluences, and also to the versatility of such dependence for all semiconductors. The behaviour of semiconductor materials conductivity dependence on fluence presented here may be used for semiconductor dosemeters characterisitic variation forecasting under large fluence measurements and in radiation emergency dosimetry. (author).
In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alphaparticle spectrography.
The excitation function of ({alpha},{ital xn}) reactions on {sup 191}Ir (abundance 37.3%) and on {sup 193}Ir (abundance 62.7%) has been measured for the 17--55 MeV alpha-particle bombarding energy range. The stacked foil activation technique and {gamma}-ray spectroscopy were used to determine the cross sections. The experimental data were compared with calculated values obtained by means of a geometry-dependent hybrid model. The initial exciton number {ital n}{sub 0}=4 with {ital n}=2, {ital p}=2, and {ital h}=0 gives the best agreements with the presently measured results. To calculate the excitation function theoretically a computer code was used. This set of excitation functions provides a data basis for probing the validity of combined equilibrium and preequilibrium reaction models in a considerable energy range.
We consider particle evaporation and fission of an ensemble of hot, rotating compound nuclei as a stochastic process. We derive a set of coupled differential equations formed by a Fokker-Planck equation describing fission, and master equations for calculating particle evaporation. From these equations, we are able to determine multiplicities of prefission neutrons, protons and {alpha}-particles, their energy spectra and their angular momentum distributions. A comparison of our results with experimental data provides us with information regarding the reduced friction coefficient {beta}, the fission barrier height and the level density parameter. For different iridium isotopes, ({sup 181,185,187}Ir), {sup 185}Os and {sup 158}Er, we obtain as an upper limit {beta}{<=}8.0x10{sup 21} s{sup -1}. (orig.).
We consider particle evaporation and fission of an ensemble of hot, rotating compound nuclei as a stochastic process. We derive a set of coupled differential equations formed by a Fokker-Planck equation describing fission, and master equations for calculating particle evaporation. From these equations, we are able to determine multiplicities of prefission neutrons, protons and #alpha#-particles, their energy spectra and their angular momentum distributions. A comparison of our results with experimental data provides us with information regarding the reduced friction coefficient #beta#, the fission barrier height and the level density parameter. For different iridium isotopes, ("1"8"1","1"8"5","1"8"7Ir), "1"8"5Os and "1"5"8Er, we obtain as an upper limit #beta##<=#8.0x10"2"1 s"-"1. (orig.).
An ionization chamber with fast timing properties was built at CERN for measuring fission cross-sections of minor actinides at the n(_)TOF neutron beam. The design of this new chamber and of the front-end electronics was optimized to match the innovative features of the n(_)TOF facility, in particular the high instantaneous neutron flux and low background. For the most radioactive isotopes, a special version of the chamber, designed according to the ISO2919 standards, was built in order to comply with the radioprotection requirements at CERN. The detector and front-end electronics are here described, together with the simulated and measured response to fission fragments and #alpha#-particles. The performances of the chamber during the first measurement campaign at n(_)TOF are presented, focusing in particular on the fast time response, the good background rejection capability, low-background and high detection efficiency.
Studies begun during the first year of this project on biopsies from spontaneous tumors in dogs and from human patients undergoing radiotherapy treatment were continued. The results indicate that significant fractions of the spontaneous tumors in dogs and cervical carcinomas in patients undergoing radiotherapy have a DNA content higher than normal diploid cells. The higher DNA content in tumor cells permits distinguishing them from normal cells in the biopsy material with the aid of flow microfluorometric (FMF) instrumentation or multiangle light-scatter spectrometry.
Purpose: To conduct a retrospective analysis within a large university teaching hospital, comparing outcomes between patients receiving either radical surgery or radiotherapy as curative treatment for bladder cancer. Patients and Methods: Between March 1996 and December 2000, 169 patients were treated radically for muscle-invasive bladder cancer. Data were collected from patient notes. Statistical analyses were performed using Kaplan-Meier methods and Cox proportional hazards regression analysis to compare radiotherapy and surgical outcome data. Results: There was no difference in overall, cause-specific, and distant recurrence-free survival at 5 years between the two groups, despite the radiotherapy group being older (median age, 75.3 years vs. 68.2 years). There were 31 local bladder recurrences in the radiotherapy group (24 solitary), but there was no significant difference in distant recurrence-free ...
PurposeTo conduct a retrospective analysis within a large university teaching hospital, comparing outcomes between patients receiving either radical surgery or radiotherapy as curative treatment for bladder cancer.Patients and MethodsBetween March 1996 and December 2000, 169 patients were treated radically for muscle-invasive bladder cancer. Data were collected from patient notes. Statistical analyses were performed using Kaplan-Meier methods and Cox proportional hazards regression analysis to compare radiotherapy and surgical outcome data.ResultsThere was no difference in overall, cause-specific, and distant recurrence-free survival at 5 years between the two groups, despite the radiotherapy group being older (median age, 75.3 years vs. 68.2 years). There were 31 local bladder recurrences...
The initial management of nonfunctioning pituitary macroadenomas (NFAs) is usually surgery; however, a significant proportion of NFAs may require further treatment. Radiotherapy is currently used in patients with residual tumour and achieves excellent long-term control, but there are concerns about potential late toxicity. Stereotactic radiotherapy, both in the form of radiosurgery or fractionated stereotactic radiotherapy, has been developed as a more accurate technique of irradiation with more precise tumour localization and consequently a reduction in the volume of normal tissue, particularly the brain, irradiated to high radiation doses. A review of the literature suggests that new radiation techniques offer safe and effective treatment for recurrent or residual pituitary adenomas; how...
The purpose of this article is to review the literature for clinical presentation, treatment, outcome and complications of using radiotherapy for the treatment of orbital lymphoma. For this, MEDLINE,...Full Text Available
Objective: To evaluate the effect of metallic stent combined with stereotactic conformal radiotherapy (SCRT) for hilar cholangiocarcinoma. Methods: Fifty-four patients with hilar cholangiocarcinoma were analyzed, including 31 treated with stent plus stereotactic conformal radiotherapy (combined group) and 23 with metallic stent alone (control group). Results: The mean survival time of combined group was 11.1 #+-# 4.6 months, compared with 5.1 #+-# 2.8 months of the control group, giving a significant difference between the two groups (P<0.01). Conclusion: The combination of metallic stent and stereotactic conformal radiotherapy is more effective than metallic stent alone for unresectable hilar cholangiocarcinoma. (authors)
ObjectivesTo assess the influence of epigallocatechin-3-gallate (EGCG) on the efficacy of ionizing radiation on prostate cancer cells because of the increased use of dietary interventions, especially by patients with prostate cancer. Radiotherapy is used to treat localized prostate cancer. Some people consume green tea (EGCG) as a chemopreventive agent against prostate cancer. Green tea can act as an antioxidant and induce superoxide dismutase enzymes, which could scavenge the free oxygen radicals generated by radiotherapy. MethodsProstate cancer cell line DU145 cells were treated with EGCG or radiotherapy, or both. Cell death was assessed using trypan blue cell counting, and apoptosis was confirmed by assessing poly (adenosine phosphate ribose) polymerase cleavage. The antioxidant potenti...
The objective of this project was to implement a centralised data base of internal quality control in radiotherapy according to the criteria of the decree of A.f.s.s.a.p.s. (French agency of sanitary safety of health products on 27 july 2007, about the internal quality control of external radiotherapy facilities. The software on one year meets the objectives: compliance by comparison with A.f.s.s.a.p.s. criteria but particularly optimization of the centralisation and analysis of the internal quality controls. (N.C.)
Previous research with individuals undergoing surgery or diagnostic procedures provided a conceptual framework for analysis of radiation therapy, a common form of cancer treatment. The present...Full Text Available
Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site....Full Text Available
Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alphaparticle radiation from the device packaging and therapeutic doses(up to 70 G{gamma}) of high energy radiation used in radiation oncology. The effects of alphaparticle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset (SEU) as the main pervasive ionising radiation threat to the reliability of implantable devices. A ...
Iron is one of the main constituents of stainless steel which is used as a structural material in nuclear reactors. In fast and conceptual fusion and fusion-fission hybrid systems the primary energy range of neutron interaction lies between 1 and 20 MeV which opens up several reaction channels. The reaction cross-sections in this energy range are important for dosimetry, radiation damage, neutronics and safety studies of nuclear reactors. Keeping this in view Nuclear Data Section of the International Atomic Energy Agency has sponsored a Research Co-ordination Programme on Methods for the Calculation of Fast Neutron Nuclear Data for Structural Elements. Under this programme we propose to study (n,n'), (n,2n), (n,3n), (n,p), (n,np), (n,pn), (n,#alpha#), (n,n#alpha#), (n,#alpha#n) and (n,#gamma#) reaction cross-sections. Besides these, total, elastic and discrete level inelastic scattering cross-sections, angular distributions of neutron production cross-sections, neutron emission ...
K and L-shell x-ray production cross sections were measured using #alpha#-particle beams of 14.00 to 34.16 MeV. The K-shell measurements ranged from Z = 20 to Z = 50 and included Ca, Sc, Ti, V, Fe, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Mo, Ag, In, and Sn while the L-shell measurements ranged from Z = 55 to Z = 92 and included Cs, Ba, Ce, Gd, Tm, Lu, Au, Pb, Th, and U. Thin metallic foils were used for the measurements and corrections for self-attenuation were negligible. A liquid nitrogen cooled Si(Li) detector and associated pulsed optical electronics were used in detecting x-rays. Absolute cross sections with an uncertainty of +-10 percent are presented for the elements measured. Also smoothed cross sections are presented which were generated by a three term polynomial fit of the experimental data points. By use of available fluorescence yields the K-shell data were converted to ionization cross sections and compared to various theoretical models. The data suggest the ...
The giant resonance regions of {sup 90}Zr, {sup 116}Sn, {sup 144}Sm and {sup 208}Pb were investigated using 240 MeV {alpha} particle scattering at small angles including 0 deg. E1 strengths corresponding to 91{+-}11%, 89{+-}10%, 105{+-}12% and 95{+-}13% of the isoscalar E1 energy-weighted sum rule were identified between 18{<=}E{sub x}{<=}31 MeV, 16{<=}E{sub x}{<=}30 MeV, 15{<=}E{sub x}{<=}27 MeV and 15{<=}E{sub x}{<=}25 MeV with centroid energies of 24.8{+-}0.4 MeV, 22.5{+-}0.3 MeV, 21.6{+-}0.3 MeV and 19.3{+-}0.3 MeV and rms widths of 3.2{+-}0.2 MeV, 3.5{+-}0.2 MeV, 3.2{+-}0.2 MeV and 2.5{+-}0.2 MeV for {sup 90}Zr, {sup 116}Sn, {sup 144}Sm and {sup 208}Pb, respectively. Parameters obtained for the isoscalar giant monopole resonance, isoscalar giant quadrupole resonance and high energy octupole resonance are in agreement with accepted values.
The giant resonance regions of "9"0Zr, "1"1"6Sn, "1"4"4Sm and "2"0"8Pb were investigated using 240 MeV #alpha# particle scattering at small angles including 0 deg. E1 strengths corresponding to 91#+-#11%, 89#+-#10%, 105#+-#12% and 95#+-#13% of the isoscalar E1 energy-weighted sum rule were identified between 18#<=#E_x#<=#31 MeV, 16#<=#E_x#<=#30 MeV, 15#<=#E_x#<=#27 MeV and 15#<=#E_x#<=#25 MeV with centroid energies of 24.8#+-#0.4 MeV, 22.5#+-#0.3 MeV, 21.6#+-#0.3 MeV and 19.3#+-#0.3 MeV and rms widths of 3.2#+-#0.2 MeV, 3.5#+-#0.2 MeV, 3.2#+-#0.2 MeV and 2.5#+-#0.2 MeV for "9"0Zr, "1"1"6Sn, "1"4"4Sm and "2"0"8Pb, respectively. Parameters obtained for the isoscalar giant monopole resonance, isoscalar giant quadrupole resonance and high energy octupole resonance are in agreement with accepted values.
We report on a new experimental approach to the size estimation of the hot spot induced by ionizing particles in a Josephson tunnel junction. Here, in contrast to the case of a superconducting strip, it is possible to investigate the hot spot dynamics in absence of effects due to the heating induced by the bias current. The reported experiment is based on the motion of Abrikosov vortices, trapped in the thin films constituting the junction electrodes, under 5.6 MeV {alpha}-particle irradiation. The fast time evolution of a hot spot, combined with the presence of Abrikosov vortices, produces a change of the static magnetic field in the junction area and thus a change of the critical current value, I{sub c}. Measurements of I{sub c} during the {alpha}-particle irradiation and in presence of trapped Abrikosov vortices allow to determine the rate of appearance of those I{sub c} changes. The behavior of the average appearance rate as function of the ...
The excitation function of the {sup 64}Ni({alpha},p){sup 67}Cu reaction was measured from threshold up to 24 MeV in order to investigate the possibility of production of the {beta}{sup -}-emitting therapeutic radioisotope {sup 67}Cu (T{sub 1/2}=61.9 h). Two stacks of thin metallic self-supporting foils of {sup 64}Ni (enrichment 77.8%) prepared by electrolytic deposition were irradiated by {alpha}-particle beams. The radioactivity was determined via HPGe detector {gamma}-ray spectrometry. Some {sup 67}Ga activity (which emits the same {gamma}-rays as {sup 67}Cu), formed via the {sup nat}Cu({alpha},x){sup 67}Ga process on trace copper impurity in the Ni foils, was also observed. Corrections were done for {sup 67}Ga activity contribution and for the {sup 67}Cu activity escape fraction from the thin Ni-foil. The maximum cross section of the {sup 64}Ni({alpha},p){sup 67}Cu reaction amounts to 34 mb at 22 MeV. The experimental results were compared with theoretical ...
Energy and angular double differential cross-section data of fragments by tens of MeV neutron or proton are important to evaluate dosimetry and radiation effect in devices or instruments, since fragments cause a large local ionization. Up to now, experimental data of the fragment production are very scarce due to experimental difficulties of fragment detection. A bragg curve spectrometer (BCS) for fragment measurement is a gridded-ionization chamber that identify fragments on the basis of the difference of Bragg peak value. The BCS was fabricated to adopt for fragment measurement in neutron-induced reactions and tested with a charged-particle beam and then applied to a neutron field successfully. The structure of BCS is a cylindrical gridded ionization chamber, and filled with a Ar + 10% CH{sub 4} gas at a pressure of 2.7 x 10{sup 4} Pa. To confirm the performance of BCS, the following tests were performed: 1) the saturation property by using {sup 241}Am {alpha} source, and 2) the Z ...
This paper describes activation measurements of the neutrons from fusion plasmas. We are primarily interested in two narrow bands of neutron energies around 2.5 and 14 MeV. The d-d reaction has two branches with nearly equal probability, one generating a 0.8 MeV {sup 3}He nucleus and a 2.45 MeV neutron, the other a 1 MeV triton and a 3 MeV proton. The d-t fusion generates a 3.5 MeV alphaparticle and a 14 MeV neutron. The triton burnup can be defined as the ratio of triton removal rate to triton generation rate. The burnup depends on how well the tritons are confined in the plasma during their slowing down to energies that make d-t fusion probable. It is important to study the tritons as they have similar kinematics to the 3.5 MeV alphaparticles in a d-t plasma. Threshold reactions make a distinction between 2.5 and 14 MeV neutrons possible. For calculating the triton burnup, the total emission from ...
A recently developed neutron diagnostic probe system has the potential to satisfy a significant number of van-mobile and fixed- portal requirements for nondestructive verification of sealed munitions and detection of contraband explosives and drugs. The probe is based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutrons generated from the deuterium-tritium reaction and that detects the alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron inelastic scattering and fission reactions identify nuclides associated with all major chemicals in chemical warfare agents, explosives, and drugs, as well as many pollutants and fissile and fertile special nuclear material. Flight times determined from determined from detection times of the gamma-rays and alpha-particles yield a separate tomographic image of each identified ...
Results of treatment of 30 children with Ewing's sarcoma irradiated in the First Radiotherapy Department, Cancer Center, Warsaw, in the period 1983-1992, are described. In 40% of patients NED survival from 1 till 10 years and in 70% the local control was obtained, and no serious radiations equelae were observed. (author).
In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.
BackgroundThe purpose of this study was to analyze the radiotherapy (RT) quality assurance (QA) assessment in Japan Clinical Oncology Group (JCOG) 0202, which was the first trial...Full Text Available
This report summarizes the activities and major accomplishments for the Idaho National Laboratory Advanced Radiotherapy Research Program for calendar year 2004. Topics covered include boron analysis in biological samples, computational dosimetry and treatment planning software development, medical neutron source development and characterization, and collaborative dosimetry studies at the RA-1 facility in Buenos Aires, Argentina.
This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.
This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.
Lysozyme chloride was administered to 84 patients of laryngeal cancer and the clinical effect was discussed. Lysozyme chloride delayed the appearance of swelling and white plaque while it accelerated that of inflammatory erythema in radiotherapy. No difference of the local inflammation was found between lysozyme administered groups and not administered groups when irradiation and chemotherapy were combined. Any side effect was not seen in blood picture of all cases by using lysozyme chloride.
The authors describe their experience of endocavitary radiotherapy of adenomas and carcinomas of the lower rectum. The method is an alternative for patients who cannot undergo standard surgical procedure or do no want a permanent colostomy. This method is cheap, fast and causes little discomfort to the patients, gives reasonable long-term results and has low morbidity. 11 refs., 4 figs., 2 tabs.
Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.
In consistency with the increasing requests from Member States for establishing radiotherapy programmes, an IAEA Technical Co-operation project was initiated in Latin America aimed at improving the physical aspects (as a complement to the clinical issues) of quality assurance in radiotherapy; this ARCAL XXX project (RLA/6/032) was classified as a Model Project of the IAEA. Among the important outcomes of the project were (i) the training of a considerable number of medical physicists in hospitals of the region, (ii) the development of a protocol for quality control procedures, and (iii) the organization of quality audit site visits (to the participant countries) where the implementation in hospitals of the developed quality control procedures is verified. The present publication is the protocol for quality control of the physical aspects of radiotherapy. It contains detailed procedures on what should be measured by a ...
Twenty-seven histologically confirmed cases of localised Ewing's sarcoma were treated by two different regimes. Radiotherapy alone was used in 13 cases and a combination of chemotherapy and radiotherapy in 14. Single agent chemotherapy (cyclophosphamide) was given sequentially in nine patients and cyclophosphamide and actinomycin-D in five. There is a significant difference in the response to these different regimes. Only 69.2% of patients treated by radiotherapy alone were disease-free, for a median period of 10.4 months and metastases were noticed in 53.8% of cases. The disease-free survival in patients treated by combination therapy (radiotherapy and chemotherapy) was 18.4 months and metastases were seen in only 42.9%. However, no metastases were seen in patients who received cyclophosphamide and actinomycin-D, during a period of 14 months and only one patient showed residual disease. It is concluded ...
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a ...
All microRNA (miRNA) target—finder algorithms return lists of candidate target genes. How valid is that output in a biological setting? Transcriptome analysis has proven to be a useful approach...Full Text Available
The evaluation of radiotherapy and surgery as exclusive local treatment in comparably selected subgroups of patients with Ewing's sarcoma on the basis of the CESS 86-data. In the German multicenter Ewing's sarcoma study CESS 86, treatment consisted for four 9-week-courses of VACA- or VAIA-chemotherapy plus local therapy. VACA (vincristine, actinomycin D, cyclophosphamide, adriamycin) was given in low-risk extremity tumors with a tumor volume below 100 cm"3. Highrisk patients with central lesions or a tumor volume >100 m"3 received VAIA (ifosfamide instead of cyclophosphamide). Local therapy started after one complete chemotherapy course in week 10. Based on an individual decision in each patient, local therapy was either radical surgery or resection plus postoperative irradiation with 45 Gy or definitive radiotherapy with 60 Gy. Because of poor results with radiotherapy in a preceeding study, it was intended to restrict ...
Radiotherapy recent development in cancer treatment needs strong procedures and quality assessment to improve safety both for patients and professionals. In Ile de France territory, a coordinated action between ASN inspectors and medical doctors specialized in public health (MISP), working as civil servants in health administration, was initiated at the end of 2007. An inspection guideline was implemented in a workshop between ASN and Regional Hospital Agency (ARH). The MISP as health administrator has to verify if care organisation responds to treatment cancer regulatory framework: as a doctor he is authorized to access to patient records to know which treatment was chosen. He has to assure if the therapeutic guidelines are respected. His comprehensive approach is essentially patient-oriented. The MISP inspection coordinated with ASN inspectors is a very pertinent pluri-disciplinary approach, undeniably necessary in such a medical technic. The effectiveness of the ...
Proton and alphaparticle spectral shapes and multiplicities have been measured in coincidence with evaporation residues from {sup 28}Si+{sup 165}Ho and {sup 16}O + {sup 197}Au, {sup 208}Pb fusion reactions. Our experiments used 145 to 220 MeV {sup 28}Si and 115 and 140 MeV {sup 16}O beams produced with the Stony Brook LINAC. ER`s were separated using an electrostatic deflector and detected with large area surface barrier detectors. Light charged particles were detected at forward and backward angles with fourteen single NaI detectors. In the context of the statistical model, charged particle spectra yield information about emission barriers and compound nucleus equilibrium level densities. These are significant ingredients in calculations determining fission timescales from other observables such as pre-scission neutron multiplicities or fusion-evaporation excitation functions. Results will also be compared to analyses of pre-scission charged ...
The use of the ratio of the characteristic intensity to the continuum background intensity (P/B ratio) of the X-ray spectrum for a quantitative ion microprobe (IMP) or PIXE (particle induced X-ray emission) analysis of thin biological specimens was proposed previously. The IMP analysis of thick biological specimens is also of considerable practical use. In this paper, the possibility of using the P/B ratio to quantify minor elements in thick biological specimens is investigated. The epoxy resin based standards with gradual concentrations of KCNS up to 0.6 mol/kg and NBS bovine liver were analyzed by a 27 MeV {alpha} particle microprobe. The measured peak to background ratios (between 4.4 to 5.7 keV) agreed well with the theoretical calculations. The calculations showed that the concentration dependence of the P/B ratios was determined mainly by the absorption of X-rays in specimens. The results indicate that the P/B method is useful for IMP ...
The large uranium fission cross section leading to iodine and the behaviour of this element in the cladding tube during energy production and afterwards during waste storage is a crucial problem, especially for {sup 129}I which is a very long half-life isotope (T=1.59 x 10{sup 7} yr). Since a combined external and internal oxidation of the zircaloy cladding tube occurs during the reactor processing, iodine diffusion parameters in zirconia are needed. In order to obtain these data, stable iodine atoms were first introduced by ion implantation into zirconia with an energy of 200 keV and a dose equal to 8 x 10{sup 15} at cm{sup -2}. Diffusion profiles were measured using 3 MeV alpha-particle Rutherford backscattering spectrometry at each step of the annealing procedure between 700 C and 900 C. In such experiments a reduced iodine concentration was observed, which correlated to a diffusion-like process. Similar analysis has been performed using radioactive {sup 131}I ...
Active oxygens produced by low-dose irradiation can induce the synthesis of proteins involved in the active oxygen reduction path and can activate the chemical self-defense mechanisms in vivo, which can alleviate the injuries caused by active oxygens themselves. The following findings suggests that it is not only by low-dose irradiation that can induce the responses described above but also by any physical and/or chemical stresses which can produce small amount of active oxygens in vivo. 1. X-irradiation with 0.5 Gy and/or water immersion and restraint induced heat shock protein (HSP)70 in rat stomach cells. HSP70 was also induced in adrenal cells by paraquat administration. 2. The SOD activity in pancreas of rat significantly increased by #gamma#-irradiation with 0.5 Gy. 0.5 Gy irradiation preceeding the alloxan administration significantly suppressed the increase in pancreatic lipid peroxides and in blood glucose levels, degranulation in #beta# cells, and decrease in blood insulin ...
Data by Wiesmann et al. on the temperature coefficient of the upper critical field, dH/sub c/2(T)/dT, and the normal-state resistivity rho_0 near the superconducting transition temperature T/sub c/ are analyzed to estimate the bare density of states N (E/sub F/) as a function of structural disorder and T/sub c/ in various #alpha#-particle irradiated samples of A-15 Nb_3Ge and Nb_3Sn. By taking into account the change in the electron-phonon coupling strength with T/sub c/ and the effect of mass enhancement arising from the electron-phonon interaction, the results of the new analysis indicate that (i) the drop in N (E/sub F/) for Nb_3Ge is relatively small as T/sub c/ changes from approx. 21 to approx. 4 K, in agreement with a recent low-temperature specific-heat measurement; (ii) the value of N (E/sub F/) in Nb_3Sn decreases by a factor of approx. 4 as T/sub c/ varies from approx. 18 to approx. 3 K. The implication of these findings is discussed in terms of the ...
Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alphaparticle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm{sup -3}. The average radon concentration in four of the caves was low in the range 74-114Bqm{sup -3}. However, one cave showed an average radon concentration of 451Bqm{sup -3}. Radon is not a problem for ...
Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alphaparticle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm"-"3. The average radon concentration in four of the caves was low in the range 74-114Bqm"-"3. However, one cave showed an average radon concentration of 451Bqm"-"3. Radon is not a problem for tourists in ...
Tensile specimens 60 ..mu..m thick of Ni-8 at. % Si have been bombarded at 475/sup 0/C to doses of 0.1 to 0.3 dpa with either 7 MeV proton or 28 MeV alphaparticle beams. Deliberate embrittlement by high temperature (700/sup 0/C) preimplantation of helium was required to produce intergranular fracture. Depth profile sputtering and analysis in a Scanning Auger Microprobe was then used to study radiation-induced segregation of silicon both at the external surfaces and at internal interfaces. The external surfaces exhibited a strongly silicon-enriched zone for the first 10 to 20 nm followed by a broad (approx.200 nm), shallow silicon-depleted region. Segregation of silicon to grain boundaries varied from interface to interface and possibly from region to region on a given interface. In general, however, depth profiles of silicon content with distance from internal boundaries showed no noticeable depletion zone and a more gradual fall-off compared ...
High spin states of the proton rich nuclei in the mass region A {approx} 100 have been studied at the GASP spectrometer through the evaporation of light charged particles and heavier ions detected in the 4{pi} Si-ball Isis. Rear side injection and pulse shape analysis have allowed a good discrimination among protons, alphaparticles and heavy ions up to C. Of the several nuclei populated in the reactions we will discuss here the high spin states of {sup 105} Sn. In addition to an extension of the spherical level, scheme, a regular sequence of dipole transitions has been found, The states of the dipole band are suggested to be built on a neutron h{sup 2}{sub 11/2} excitation coupled to proton particle-hole states, which polarize the core to a slightly prolate shape. The experimental results are in agreement with the prediction of tilted axis cranking calculations, which satisfactorily explain the properties of the band. (author) 17 refs., 4 ...
GaN and Al{sub 1{minus}x}Ga{sub x}N films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10{sup 9} ohm-cm and 10{sup {minus}3}--10{sup {minus}8} cm{sup 2}/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alphaparticles using GaN detectors.
GaN and Al_1_-_xGa_xN films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10"9 ohm-cm and 10"-"3--10"-"8 cm"2/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alphaparticles using GaN detectors.
The performance of the gas-jet transport system coupled to the RIKEN gas-filled recoil ion separator GARIS was investigated using 255No produced in the 238U(22Ne, 5n)255No reaction. Alphaparticles of 255No separated with GARIS and transported by the gas-jet system were measured with a rotating wheel apparatus for ? spectrometry under low background condition. The high gas-jet efficiencies of about 75% were independent of the recoil ranges of 255No in the gas-jet chamber. The present results suggest that the GARIS/gas-jet system is a promising tool for the next-generation superheavy element chemistry: (1) the background radioactivities of unwanted reaction products are strongly suppressed, (2) the intense beam is absent in the gas-jet chamber and hence the high gas-jet efficiency is achieved, and (3) the beam-free condition also allows for investigations of new chemical systems. (author)
The differential cross sections for neutron emission in the reactions {sup 115}In(p,xn), {sup 115}In(d,xn), and {sup 113}Cd({alpha},xn) are measured and analyzed for proton energies 11.2 and 22.2 MeV, deuteron energy 22.3 MeV, and {alpha}-particle energies 26.8 and 45.2 MeV, respectively. The parameters of the nuclear-level density in the Fermi-gas model with negative energy shift are determined for the {sup 113}Sn, {sup 114}Sn, {sup 115}Sn, and {sup 116}Sn nuclei over a wide range of excitation energies. Analysis is performed in a statistical model that uses the Hauser-Feshbach mathematical formalism to describe multistage processes. It is shown that, as excitation energy increases, the parameter of the level density for these nuclei first decreases (this behavior is consistent with the predictions of the generalized model of a superfluid nucleus) and then increases (this points to the destruction of the nuclear-shell structure). 20 refs., 6 figs., 2 tabs.
We calculate the structure of accretion disks around Kerr black holes for accretion rates 0.001 - 10 M_sun/s. Such disks are plausible candidates for the central engine of gamma-ray bursts. Our disk model is fully relativistic and treats accurately microphysics of the accreting matter: neutrino emissivity, opacity, electron degeneracy, and nuclear composition. The neutrino-cooled disk forms above a critical accretion rate that depends on the black hole spin. The disk has the ``ignition'' radius r_ign where neutrino flux rises dramatically, cooling becomes efficient, and the proton-to-nucleon ratio Y_e drops. Other characteristic radii are r_alpha where most of alpha-particles are disintegrated, r_nu where the disk becomes neutrino-opaque, and r_trap where neutrinos get trapped and advected into the black hole. We find r_alpha, r_ign, r_nu, r_trap and show their dependence on the accretion rate. We discuss the qualitative picture of accretion and present sample ...
As with science, so with security--in both arenas, the extraordinary sensitivity of cryogenic sensors enables high-confidence detection and high-precision measurement even of the faintest signals. Science applications are more mature, but several national and international security applications have been identified where cryogenic detectors have high potential payoff. International safeguards and nuclear forensics are areas needing new technology and methods to boost speed, sensitivity, precision and accuracy. Successfully applied, improved nuclear materials analysis will help constrain nuclear materials diversion pathways and contribute to treaty verification. Cryogenic microcalorimeter detectors for X-ray, gamma-ray, neutron, and alpha-particle spectrometry are under development with these aims in mind. In each case the unsurpassed energy resolution of microcalorimeters reveals previously invisible spectral features of nuclear materials. Preliminary results of ...
Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, selenium, vitamin E, and 5-aminobenzamide that inhibit the expression of transformation. ...
Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, selenium, vitamin E, and 5-aminobenzamide that inhibit the expression of transformation. ...
Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emissions (2-20 keV) and 3.5 MeV Alphaparticle emissions from laser driven micro-implosions. Image resolution in these experiments was 3-8 ..mu..m. Extension of this coded imaging capability to higher energy x-rays (approx. 100 keV) and more penetrating charged particles (e.g. approx. 15 MeV protons) requires the fabrication of very thick (50-200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5-25 ..mu..m) for use as coded aperatures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.
Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emission (2--20 keV) and 3.5 MeV Alphaparticle emissions from laser driven micro-implosions. Image resolution in these experiments was 3--8 ..mu..m. Extension of this coded imaging capability to higher energy x rays (approx.100 KeV) and more penetrating charged particles (e.g., approx.15 MeV protons) requires the fabrication of very thick (50--200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5--25 ..mu..m) for use as coded apertures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.
The low-cycle fatigue properties of the ferritic-martensitic steels MANET I and II and F82H-mod, have been investigated at a temperature of 200 C. The strain-controlled fatigue has been performed with strain ranges between 0,4% and 1,0% and at a strain rate of 8.10{sup -4} s{sup -1}. The steel F82H-mod, is characterised by a higher plastic strain amplitude compared to MANET I and II. Some of the specimens have beenirradiated with a 104 MeV {alpha}-particle beam. The homogeneous implantation of 400 appm He leads to a hardening of the material. At the beginning of the fatigue tests the stress response of the irradiatedspecimens is higher compared to the unirradiated specimens. In general, thematerial shows softening during fatigue. The softening of irradiated material, which is fatigue tested with a high total strain amplitude, is higher than that of the unirradiated material. The lifetime is reduced. For irradiated specimens fatigued at small total strain amplitudes ...
The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. The results obtained for the MMFDs produced by different technologies are presented. The MMFD deposited onto the 20 {mu}m thick Si-wafer has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator. Another MMFD with totally removed Si-wafer at the working area has been applied for the on-line X-ray BPM at the HASYLAB (DESY). One may conclude that the developed technology of the micro-strip metal detector manufacturing allows to provide non-destructive measurement of X-ray intensity distribution over area of up to 50 mm{sup 2} with an accuracy of 10-20 {mu}m with a possibility of its improvement by a factor 5. A sub-micron position resolution is expected by applying electron lithography for the strip pattern production.
The giant resonance region in several nuclei in A {>=} 90 have been re-measured using 240 MeV {alpha} particle scattering with a detector provides that both horizontal and vertical angles. Slice analyses with multipole fits were performed and strength due to both low and high energy components of the isoscalar giant dipole resonance (ISGDR) was identified. E1 strengths for the high energy component corresponding to 70{+-}15%,68{+-}15% and 67{+-}14% of the isoscalar E1 energy-weighted sum rule were identified, with centroid energies of 26.3{+-}0.6 MeV, 24.7{+-}0.6 MeV and 21.7{+-}0.6 MeV for {sup 90}Zr, {sup 144}Sm and {sup 208}Pb, respectively. The centroid of the high energy component of the strength distribution is in closer agreement with the microscopic prediction generated using compressibilities obtained from the isoscalar giant monopole resonance data.
The electrical conductivity of Vitox-alumina (99.2%), Wesgo-alumina (99.9%) and AlN (99.6%) has been measured during and after irradiation with an experimental set-up which allows fusion relevant loading conditions. All irradiations were performed in high vacuum at 450 C using a 104 MeV {alpha}-particle beam with an applied DC electric field of 100 kV/m. In the high purity Vitox-alumina the in-situ and postirradiation bulk conductivities {sigma} and {sigma}{sub 0} show the highest irradiation induced electrical breakdown ever observed. The saturation level near 4 x 10{sup -2} ({Omega}m){sup -1}, reached already after 0.015 dpa (O-sublattice), is already above the critical value necessary to avoid MHD pressure drop with 10 {mu}m coatings in flowing liquid metal coolants. Under the same conditions no radiation induced electrical degradation at all has been found in Wesgo-alumina and AlN. (orig.).
Thin Fe and Ta layers of 30-45 nm thickness, deposited via magnetron sputtering on Si (1 0 0) substrates, were bombarded at room temperature with 100 keV Ar{sup 1+} or Ar{sup 8+} or with 250 keV Xe{sup 1+} or Xe{sup 19+} ions in order to test the influence of the ion charge state on the surface sputtering and interface mixing. The samples were characterized by means of Rutherford backscattering at 0.9-3.0 MeV {alpha}-particle energy, time-of-flight elastic recoil detection analysis with a 53 MeV {sup 127}I{sup 10+} beam and atomic force microscopy. No influence of the charge state on the sputtering and athermal mixing rate was observed in the case of the Ta/Si system. However, in the case of the Fe/Si system, the ion charge was observed to have an influence on the mixing rate.
Strain controlled fatigue experiments on the modified ferritic-martensitic 12% Cr-steel Manet have been performed during, after and without irradiation. Continuous push-pull cycling of the hollow fatigue specimens with a cycle ratio R=-1, an axial strain rate of 8.10{sup -4} s{sup -1} and total strain ranges {Delta}{epsilon}{sub t} between 0.42% and 1.0% has been applied in vacuum (5.10{sup -3} Pa) at T=250 C. For the irradiation, a 104 MeV {alpha}-particle beam was used. Compared to unirradiated specimens, in-beam specimens undergo irradiation hardening at an advanced fatigue/implantation stage. Post-irradiation specimens show significantly higher total stress amplitudes and reduced fatigue lives. TEM investigations of in-beam and post-irradiation specimens reveal helium bubbles with different diameters on internal surfaces and in the matrix. (orig.).
Ti-15Mo-2.7Nb-3Al-0.2Si (Timetal-21S), a metastable #beta#-titanium alloy, is a candidate material for titanium matrix composite structures in hydrogen-fueled hypersonic planes because of its excellent formability and adequate mechanical properties in the 500--800 C temperature range. The alloy is strengthened through the precipitation of fine #alpha# particles in the #beta# matrix. The mechanical properties and microstructures are controlled by a solutionizing/aging heat treatment. A major concern in using titanium alloys in hydrogen service is the embrittlement caused by the precipitation of hydrides. It is believed that the large solubility of hydrogen in the #beta#-phase would preclude the precipitation of hydrides in Beta titanium alloys, especially at low hydrogen pressures. However, depending on the hydrogen content, a shift in the ductile/brittle transition temperatures to levels much higher than room temperature has been reported for ...
Independent isomeric yield ratios of /sup 128/Sb were determined radiochemically in the thermal neutron induced fission of /sup 241/Pu and 34 MeV alphaparticle induced fission of /sup 238/U, both involving the same compound nucleus (/sup 242/Pu). Fragment angular momenta estimated from the measured isomer ratios using the statistical model analysis showed significantly larger fragment angular momenta in the medium energy fissioning system compared to the low energy fissioning system. This has been attributed to the effect of higher excitation energy and angular momentum in the entrance channel leading to increased fragment temperature, moments of inertia and angular velocity. An attempt was made to calculate the fragment angular momentum in the medium energy fission using the Fermi gas model for the fissioning nucleus, taking into account the multichance fission, saddle shapes of the fissioning nuclei and the angular velocity components of the ...
Aluminum nitride has been proposed as electrically insulating coating in connection with blankets made of vanadium alloys. Irradiations were performed with an applied DC electric field of 100 kV/m, using a 104 MeV {alpha}-particle beam. The dose achieved were 0.1 dpa at 300 C, 0.05 dpa at 400 C, and 0.06 dpa at 500 C. The out-of-beam conductivity {sigma}{sub 0} decreased at all temperatures employed during early stage of irradiation. Before 0.02 dpa had been reached, {sigma}{sub 0} dropped to low values of typically (2-4) x 10{sup -11} ({Omega} m){sup -1}. Although a moderate increase can be observed during further irradiation, {sigma}{sub 0} remained below the initial value of the unirradiated specimen for all temperatures. That is, there is no significant evidence for radiation induced electrical degradation. The in-beam conductivity {sigma}, measured continuously during irradiation, also decreased by at least one order of magnitude. Relevant damage dose and ...
Tensile specimens of the normalized and tempered fully martensitic steel DIN 1.4914 were helium implanted up to 340 appm within the temperature range 300-720/sup 0/C using a 104 MeV alphaparticle beam. The high He/damage ratio of 1850 appm He/dpa allowed to determine the effect of helium on material properties. After irradiation tensile strength and ductility were investigated mainly at test temperatures equal to the irradiation temperatures. While short time irradiations with helium contents up to 100 appm have shown no visible effect on the tensile behaviour at all temperatures investigated, long time irradiations reduced the material strength at irradiation temperatures above about 440/sup 0/C. This irradiation induced softening obscured the predicted minor hardening effect of the observed He-bubbles completely and increases with irradiation time and temperature. The fracture mode of helium-implanted and control specimens is found to remain ...
Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties of 3D structures. Charge collection efficiencies in silicon columns from 10 to 800 ?m ...
The research on the therapy of brain tumors and others by the thermal neutron irradiation using research reactors is to kill tumor cells by accumulating boron at a tumor part, and using {alpha} particles and {sup 7}Li generated by {sup 10}B(n, {alpha}){sup 7}Li reaction of thermal neutrons, which is known as boron neutron capture therapy (BNCT). In Japan Atomic Energy Research Institute, the medical irradiation facility was installed in the thermal neutron column of the JRR-2, and as of March, 1994, 22 cases of irradiation have been carried out. In order to monitor the variation of thermal neutron flux during irradiation, the real time measurement using a simultaneous monitor is carried out, but there is the variation of measured values in the Si semiconductor, p-n junction detector possibly due to its direction dependence. The experiment was carried out to quantity the direction dependence of the detector by using the neutron radiography ...
Traditionally wafer bumps are made from Pb containing solders. Over 20 years ago IBM recognized that {sup 210}Pb has a decay chain resulting in a 5.4 MeV alphaparticle that induces soft errors. A variety of efforts to produce and characterize low alpha Pb ensued. Work at Honeywell over the past several years has shown that low alpha lead activity does not follow the decay signature predicted from {sup 210}Pb secular equilibrium. Data are presented indicating that smelting has a minimal effect on {sup 210}Pb/{sup 210}Po secular equilibrium and that other trace radionuclides are the alpha source. The implications of these data to possible alpha emitter sources in lead free solders are discussed, along with a method developed by Honeywell to remove alpha emitters from lead free solder components.
We have developed a Bragg curve counter (BCC) equipped with an active cathode to extend the energy acceptance to lower energies than for a conventional BCC to measure differential cross-sections of fragment production reactions induced by tens of MeV protons. The signal from the active cathode providing the timing signal of fragment incidence and the time difference signal between the cathode and anode gives information on the fragment range in the BCC on the basis of electron drift time. Utilization of the range information made possible identification of fragments less than 0.5 MeV/u that is lower than the identification threshold of a conventional BCC technique. After investigations on fundamental properties of a newly constructed BCC using heavy ion beams and alpha-particles, this method was applied successfully to a fragment production measurement for 70 MeV proton-induced reactions on carbon. With this technique, the energy threshold of the BCC was improved ...
The literature of radiation damage measurements on cadmium zinc telluride (CZT), cadmium telluride (CT), and mercuric iodide (HgI{sub 2}) is reviewed and in the case of CZT supplemented by new alphaparticle data. CZT strip detectors exposed to intermediate energy (1.3 MeV) proton fluences exhibit increased interstrip leakage after 10{sup 10} p/cm{sup 2} and significant bulk leakage after 10{sup 12} p/cm{sup 2}. CZT exposed to 200 MeV protons shows a two-fold loss in energy resolution after a fluence of 5 {times} 10{sup 9} p/cm{sup 2} in thick (3 mm) planar devices but little effect in 2 mm devices. No energy resolution effects were noted from moderated fission spectrum of neutrons after fluences up to 10{sup 10} n/cm{sup 2}, although activation was evident. Exposures of CZT to 5 MeV alphaparticle at fluences up to 1.5 {times} 10{sup 10} {alpha}/cm{sup 2} produced a near linear decrease in peak ...
Angiosarcoma (AS) is a rare and aggressive vascular neoplasm with very poor prognosis. Patients with extensive cutaneous AS who are not surgical candidates have very limited options since there is no...Full Text Available
This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available
Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available
BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available
Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available
The document reports the main issues discussed during the first course-debate on quality controls in radiotherapy, held in Rome in December 3-4, 1998 and May 3-5 1999 in collaboration between the Istituto Superiore di Sanita' and the Istituto Regina Elena. The points considered critical to the quality assurance in radiotherapy by the participants are presented in relation to the total radiotherapy procedure. [Italian] Questo documento e' dedicato al primo corso-dibattito sui controlli di qualita' in radioterapia svoltosi a Roma il 3-4 dicembre 1998 e il 3-5 maggio 1999 in collaborazione tra l'Istituto Superiore di Sanita' e l'Istituto Regina Elena. Esso presenta gli argomenti ritenuti critici per l'assicurazione di qualita' in radioterapia in relazione all'intera procedura radioterapica, in base alle esperienze dei partecipanti.
PurposeRadiation-induced heart disease (RIHD) is a severe side effect of thoracic radiotherapy. This study examined the effects of PTX and α-tocopherol on...Full Text Available
PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available
Background:The non-surgical management of non-melanoma skin cancers is an area requiring clinical investigation. Radiotherapy has a role in treatment for a defined subset...Full Text Available
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
Bone metastases at the thoracic and lumbar segment of the spine are usually presented with painful sensation and medullar compression. The treatment is based on the clinical and neurological conditions of the patient and the degree of tumor invasion. In the present study, 32 patients with spinal metastasis of thoracic and lumbar segment were prospectively analyzed. These patients were treated by decompression and internal stabilization followed by radiotherapy or irradiation with external immobilization. The election of the groups was in accordance with the tumor radiotherapy sensitivity, clinical conditions, spinal stability, medullar or nerve compression and patient's decision. The Frankel scale and pain visual test were applied at the moment of diagnosis and after 1 and 6 months. The surgical group had better results with preserving the ambulation longer and significant reduction of pain.(author)
Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of magnitude, yet in ...
Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of magnitude, yet in ...
The aim of this study is to develop an Automatic Post-processing Tool for four-dimensional (4D) treatment planning (APT4D) that enables the user to perform some necessary procedures related...Full Text Available
BackgroundTo compare the differences in dose-volume data among coplanar intensity modulated radiotherapy (IMRT), noncoplanar IMRT, and helical tomotherapy (HT) among patients with...Full Text Available
Between 1973 and 1978 combined radiotherapy and chemotherapy were given to 22 patients with histologically proven Ewing's sarcoma. The combined chemotherapy consisted of cyclophosphamide, vincristin, adriamycin, as well as dacarbazine in some cases. The neoplasm was a localized one at the beginning of treatment in 14 of the 22. These patients received high-voltage rediotherapy to the primary focus at a focal dose between 42 and 55 Gray (4200-5500 rad), followed by chemotherapy. After 6-8 treatment cycles, adriamycin was replaced by methotrexate. Nine of the 14 patients survived without recurrence for 12 to over 59 months. Eight patients had extensive metastases at the beginning of treatment: they at first received only chemotherapy, followed by radiotherapy or operation, as indicated. Full clinical remission was achieved in five of them: in three this remission has now lasted for more than 18, 40 and 44 months, respectively. These results ...
Hepatocellular carcinoma (HCC) is one of the most critical global health issues. With frequent association of viral liver disease, HCC is highly complex, harboring both cancer and chronic liver disease....Full Text Available
Rectum reference dose points have a direct impact on the morbidity seen in gynecological intracavitaty radiotherapy. The aim of this study is to obtain less morbidity by marking rectum with radio opaque solution. Fourteen patients with gynecological cancer who underwent external radiotherapy received 15 Gray (Gy) intracavitary radiotherapy. During the internal radiotherapy planning, radio opaque solution has been administered into the rectum to observe it on lateral radiogram. Thus rectum reference dose point and five points were marked at sites nearest to the sources. Nucletron Planning system was used for obtaining three-dimensional planning. After therapy patients were followed at every three months. Median follow-up was 18 months. Most frequently observed morbidities were grade 1-2 rectitis and cystitis in six patients. As a result, more accurate rectum dose values and less factors causing dose ...
Based on the assumption that an accelerated proliferation process prevails in tumour cell residues after surgery, the possibility that treatment acceleration would offer a therapeutic advantage in postoperative...Full Text Available
PurposeWe previously reported a randomized phase II clinical trial combining a poxvirus-based vaccine encoding PSA with radiotherapy in patients with localized prostate...Full Text Available
Aim: To systematically review the currently available high quality evidence evaluating treatments for moist desquamation in radiotherapy patients. Design: Systematic literature review. Methods: Electronic databases, websites, reference lists, key journals and conference proceedings were searched. Attempts were also made to uncover unpublished material. Relevant studies proceeded to data extraction and quality assessment. Results: Twenty studies were found; 10 were eligible for inclusion. Although many studies were small, none had unacceptably poor quality. No meta-analysis was undertaken as the studies were not homogenous in their interventions or methods. No convincing evidence for any intervention was found. Conclusion: Despite being recommended by many guidelines (College of Radiographers Summary of Intervention for Acute Radiotherapy Induced Skin Reactions in Cancer Patients (London, 2001); NHS Quality Improvement Scotland Best Practice ...
Combined treatment of 131 patients aged 3-16 with local form of Ewing's sarcoma is carried out. Survival rate per year was studied in patients without diagnosed metastases depending on chemiotherapy method. It is stated that improved results of treatment of children with Ewing's sarcoma may be achieved by combining radiotherapy with long-term systemic polychemotherapy. The most efficient and expedient method of radiotherapy of long bone sarcoma in children is dialy three-field irradiation with 2 Gy at SFD to the tumor 60 Gy, and adjacent tissues - 40 Gy.
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
A dose calculation algorithm for MLC based conformal radiotherapy is described in this paper. The algorithm is formulated by the coordinate of MLC leaves. Verification on the algorithm is made by comparing the dose distributions generated by this algorithm with that generated by a Differential Convolution Superposition algorithm for various regular and irregular fields. The results demonstrate that the present algorithm has suitable accuracy and high computational efficiency, thus it could be useful for the treatment planning process in MLC based conformal radiotherapy, where the workload for interactively or automatically designing the shapes of MLC is heavy. (authors)
Radiotherapy recent development in cancer treatment needs strong procedures and quality assessment to improve safety both for patients and professionals. In Ile de France territory, a coordinated action between ASN inspectors and medical doctors specialized in public health (MISP), working as civil servants in health administration, was initiated at the end of 2007. An inspection guideline was implemented in a workshop between ASN and Regional Hospital Agency (ARH). The MISP as health administrator has to verify if care organisation responds to treatment cancer regulatory framework: as a doctor he is authorized to access to patient records to know which treatment was chosen. He has to assure if the therapeutic guidelines are respected. His comprehensive approach is essentially patient-oriented. The MISP inspection coordinated with ASN inspectors is a very pertinent pluri-disciplinary approach, undeniably necessary in such a medical technic. The effectiveness of the ...
Purpose: To determine if involved field radiation (IF) is equivalent to standard whole bone radiation (SF) in local tumor control; to establish patterns of failure following treatment; and to determine response, event-free survival (EFS), and overall survival rates from multidisciplinary therapy in Ewing's sarcoma. Methods and Materials: Between 1983 and 1988, 184 children with Ewing's sarcoma were enrolled onto Pediatric Oncology Group 8346 (POG 8346). A total of 178 (97%) met eligibility criteria; 6 had pathology other than Ewing's sarcoma. Induction chemotherapy of cyclophosphamide/doxorubicin (adriamycin )(C/A) x 12 weeks was followed by local treatment either surgery or radiation therapy and C/A, dactinomycin, and vincristine for 50 weeks. Resection was advised for patients with small primary tumors if accomplished without functional loss. Forty patients were randomized to receive SF, whole bone radiation to 39.6 Gy plus a 16.2 Gy boost (total 55.8 Gy) or IF to 55.8 Gy, and the ...
Human antibodies targeting prostate cancer cell surface epitopes may be useful for imaging and therapy. The objective of this study was to evaluate the tumor targeting of an internalizing human...Full Text Available
Computational prediction of microRNA targets remains a challenging problem. The existing rule-based, data-driven and expression profiling approaches to target prediction are mostly approached from the...Full Text Available
In order to identify novel high value antibacterial targets it is desirable to delineate whether the inactivation of the target enzyme will lead to bacterial death or stasis. This knowledge is particularly...Full Text Available
Computational fluid dynamics(CFD) code FLUENT was used to simulate the thermal hydraulic processes occurring in conceptual design of the accelerator-driven subcritical reactor(ADSR) liquid lead target. The purpose of the analysis is to investigate the thermal hydraulic characteristics of liquid lead as ADSR target material with various target geometries and injection locations of proton beam. In the calculation analysis, the local temperature of the liquid lead target rises to the boiling temperature very rapidly. When the proton beam is injected from the bottom of the target system, the duration time to reach the boiling temperature is longer and the temperature distribution is flatter than other cases.
Experimental and computational investigations were performed in order to better understand the mechanical response of rigid targets with various geometries to the detonation of shallow buried explosives. The motion of the targets was measured by use of high-speed digital video photography. This work involved flat targets, targets that were downwardly convex, and targets that were downwardly concave with explosive charges located at various positions beneath the targets. It was observed that, in general, angled hulls - whether downwardly concave or convex - tended to reduce the amount of momentum imparted to the center of mass of the targets. Computations were performed by use of an arbitrary Langrangian-Eulerian treatment in a nonlinear finite element code. A model based on quasi-static te...
In an effort to develop octahedral metal complexes as chemotherapeutic and diagnostic agents targeted to DNA, it is critical to optimize the properties of their cellular uptake. Appending d-octaarginine...Full Text Available
The design of the absorber blocks for internal and external dumping of the SPS proton beam is discussed. In addition, the external target stations for slow and fast extracted proton beams are described.
... L. Sutton. 2000. Is the aquatic weed hygrophila, Hygrophila polysperma (Polemoniales: Acanthaceae), a suitable target for classical biological ... ...
Nato SCI-12 on Camouflage Evaluation Workshop on Search and Target Acquisition The Netherlands, June 1999. Image Discrimination Models for Object Detection ...
By W. Wayne Scott. Langley Research Center. SUMMARY. Thin- and thick-target bremsstrahlung spectra are presented for electron energies up to 7.0 MeV. ...
Radio-biologists have pointed out a novel radiobiological phenomenon observed in many tumor and normal cell lines: hyper-radiosensitivity to very low-dose (H.R.S.) followed by induced radioresistance (I.R.R.) after a threshold dose of 0.1-0.3 Gy that depends on the cell line. Radioresistance at high dose (i.e. higher than 0.5 Gy) and metastatic potential of tumor cells are likely major factors of failure in radiotherapy. A careful review of literature suggests that: 1) radiotherapy does not increase the metastatic potential of tumor cells; 2) radioresistance at high dose and metastatic potential are not related. However, inside a given tumor cell line, highly metastatic clones may elicit more cells showing H.R.S; or are more radiosensitive at high dose than poorly metastatic ones. Recent data obtained from molecular techniques (comet and immunofluorescence assays) applied to single cells irradiated at very low radiation doses (1-100 mGy) ...
Purpose: To evaluate the importance of surgical margins for local and systemic control of Ewing's sarcoma family tumors (ESFT). Methods and Materials: Between 1979 and 1999, 512 patients with ESFTs entered 4 different adjuvant and neoadjuvant studies performed at a single institution. Of these patients, 335 were treated with surgery alone (196) or surgery followed by radiotherapy at doses of 44.8 Gy (139). We compared their outcome with that of the 177 patients who were locally treated by radiotherapy at 60 Gy. Results: Local control (88.8% vs. 80.2%, p < 0.009) and 5-year disease-free survival (63.8% vs. 47.6%, p < 0.0007) were significantly better in patients treated with surgery and, among them, in those with adequate surgical margins (96.6% vs. 71,7%, p < 0.0008, and 69.6% vs. 46.3%, p < 0.0002). Nonetheless, better results were observed only in extremity tumors. Conclusions: Surgery is better than ...
The aim of this study was to evaluate the results of postoperative radiotherapy in a case of perihilar cholagiocarcinoma by analyzing overall survival rate, patterns of failure, prognostic factors for overall survival, and toxicity. Between January 1998 and March 2008, 38 patients with perihilar cholangiocarcinoma underwent a surgical resection and adjuvant radiotherapy. The median patient age was 59 years (range, 28 to 72 years), which included 23 men and 15 women. The extent of surgery was complete resection in 9 patients, microscopically positive margins in 25 patients, and a subtotal resection in 4 patients. The tumor bed and regional lymphatics initially received 45 Gy or 50 Gy, but was subsequently boosted to a total dose of 59.4 Gy or 60 Gy in incompletely resected patients. The median radiotherapy dose was 59.4 Gy. Concurrent chemotherapy was administered in 30 patients. The median follow-up period was 14 months ...
Background: the fact that therapeutic irradiation can induce significant stenosis in the arteries of the head, neck, and chest, as welt as in the aorta and the iliac arteries, is familiar in daily practice and well documented in the literature. By contrast, radiation-induced renal artery stenosis seems to be a less widely known complication. Patients and methods: the sudden onset of medically refractory arterial hypertension and coma in a 27-year-old man is reported, who had been treated at age 20 with chemotherapy and radiotherapy for Ewing's sarcoma in the lumbar region. This treatment had been performed at the hospital of Sion, Switzerland in 2001. Also, the relevant literature from 1965 to 2007 is reviewed to underscore various aspects of this problem and to demonstrate the clinical relevance of renal artery stenosis as a potential long-term sequela of radiotherapy. Conclusion: radiation-induced renal artery stenosis has only rarely been ...
Purpose: Treatment results and the pattern of relapse were evaluated in the multimodal treatment of Ewing's sarcomas of the chest wall. Methods and Materials: In a retrospective analysis, 114 patients with non-metastatic Ewing's sarcoma of the chest wall were evaluated. They were treated in the CESS 81, CESS 86, or EICESS 92 studies between January 1981 and December 1993. The treatment consisted of polychemotherapy (VACA, VAIA, or EVAIA) and local therapy, either surgery alone (14 patients), radiotherapy alone (28 patients) or a combination of both (71 patients). The median follow-up was 46.6 months (range 5-170). A relapse analysis for all patients with local or combined relapses was performed. Results: Overall survival was 60% after 5 years, event-free survival was 50%. Thirty-seven patients had a systemic relapse (32.4%), 11 patients had a local relapse alone (9.6%), and 3 patients had a combined local and systemic relapse (2.6%). The risk to relapse locally ...
Background and purpose: To assess the effectiveness of radiotherapy in preventing tumour seeding after chest drain or pleural biopsy in patients with malignant mesothelioma and to determine, if tract metastases appear, whether they are tender or troublesome to patients. Patients and methods: Patients with a histological diagnosis of pleural mesothelioma and an invasive procedure within the preceding 21 days were stratified by age, performance status and treatment centre. Randomisation was performed between immediate drain site radiotherapy 21 Gy in three fractions (XRT arm) or best supportive care (BSC) with follow-up to 12 months. Patients were asked to complete questionnaires on treatment toxicity and on symptoms from any tract metastases detected. Results: Sixty-one patients were recruited from two centres between 1998 and 2004; 56 men, 5 women, median age 70. 31 were allocated to drain site radiotherapy. Seven patients ...
The National Ignition Facility (NIF) is a proposed Department of Energy facility which will contribute to the resolution of important Defense Program and inertial fusion energy issues for energy production in the future. The NIF will consist of a laser system with 192 independent beamlets transported to a target chamber. The target chamber is a multi-purpose structure that provides the interface between the target and the laser optics. The chamber must be capable of achieving moderate vacuum levels in reasonable times; it must remain dimensionally stable within micron tolerances, provide support for the optics, diagnostics, and target positioner; it must minimize the debris from the x-ray and laser light environments; and it must be capable of supporting external neutron shielding. The chamber must also be fabricated from a low neutron activation material. The fusion reaction in the ...
The lymphographic agent Lipiodol (iodized oil) has been found to localize and remain in tumor vessels. Based on this finding, we attempted transcatheter internal radiotherapy by radioactive iodized oil (I-131 tagged Lipiodol) prepared by isotopic exchange reaction. Transcatheter internal radiotherapy (TCIR) was attempted in twelve patients with inoperable hepatoma by infusing a therapeutic dose of I-131 Lipiodol (7.6 approx. 28.3 mCi/2.0 approx. 5.0 ml) via the hepatic artery. Serial changes of serum alpha-fetoprotein (AFP) levels and in the size of tumor on computed tomography (CT) were estimated to evaluate the therapeutic effect. Serum AFP levels decreased in 9 patients with initial elevated levels of serum AFP, although they were again elevated in three of them within four weeks. More than 50 % decrease in tumor size was observed in 6 patients (50 %). There were no serious complications. This preliminary results suggest that TCIR with I-131 ...
A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement of beam energy, ...
This SBIR Phase I developed neutron detectors made from gallium arsenide (GaAs) p-type/ intrinsic/n-type (P-I-N) diodes grown by metalorganic chemical vapor deposition (MOCVD) onto semi-insulating (S1) bulk GaAs wafers. A layer of isotonically enriched boron-10 evaporated onto the front surface serves to convert incoming neutrons into lithium ions and a 1.47 MeV alphaparticle which creates electron-hole pairs that are detected by the GaAs diode. Various thicknesses of ''intrinsic'' (I) undoped GaAs were tested, as was use of a back-surface field (BSF) formed from a layer of Al{sub x}Ga{sub 1-x}As. Schottky-barrier diodes formed from the same structures without the p+ GaAs top layer were tested as a comparison. After mesa etching and application of contacts, devices were tested in visible light before application of the boron coating. Internal quantum efficiency (IQE) of the best diode near the GaAs bandedge ...
We proposed a solid and a mercury target concepts through the preliminary conceptual design. To feasible these concepts, analysis and experimental works are being carried out. This paper introduces an outline of present status of target R and D such as heat transfer augmentation experiments for the solid target, mercury flow tests with a loop of maximum flow rate of 15L/min, flow pattern measurements for a cold source moderator etc. as well as preliminary conceptual design works. (author)
We present our initial experience with a new biodegradable (BD) esophageal stent in two patients, one for a therapy-resistant benign esophageal stricture, and the other as a temporary measure during curative radiotherapy for oesophageal carcinoma. The BD stents need to be loaded into a conventional pull-back delivery system but are then placed in a standard fashion. Pre-dilatation should be avoided to reduce the risk of migration, however if migration occurs the stents can be left to dissolve in the stomach. The stents are radiolucent but easily identified on CT with minimal artefact and thus might even aid with radiotherapy planning. BD stents offer an exciting new strategy for therapy-resistant benign strictures as well as a supportive measure for oesophageal cancer undergoing non-surgical treatment. (orig.)
The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)
During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose "kernels" partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even furt...
Local control of Ewing's sarcoma was analysed in a series of 67 patients treated by surgery and/or radiotherapy as well as combination chemotherapy. Radiotherapy was employed with or without surgery in 60 patients and produced an overall local control rate of 55%; complete excision of the primary lesion seemed to be beneficial. There was a marked variation in control rates depending on the site of the primary lesion: limb 85%, rib 53%, pelvis 31% and other sites 33%.Primary tumours greater than 10 cm in diameter were significantly less likely to be controlled. Using daily fractions of approximately 180 cGy, total doses in excess of 6000 cGy seem more likely to produce serious late morbidity amd may not increase the local control rate. No cases of second malignancy arising in irradiated tissue have been observed to date, but one patient developed acute lymphoblastic leukaemia. (author).
The purpose of this note is to provide guidance to those who have duties under the Health and Safety at Work Act and other relevant legislation. It gives guidance on the practical application of legislation, concerning radiotherapy equipment. Two particular issues arise out of the requirements of Regulation 33 of the Ionising Radiations Regulations 1985 (IRR85) in relation to equipment which is used for medical exposures. These are the requirement to select, install and maintain this type of equipment in such a way that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person where this is compatible with the intended clinical purpose, including the need to ensure that equipment used for radiotherapy is properly calibrated, and the requirement to notify the Health and Safety Executive (HSE) when an incident occurs involving a malfunction or defect in any 'radiation equipment' which ...
The behaviors of peripheral eosinophils during radiotherapy were examined in 200 cases of non-resected cervical cancer. Before irradiation, the mean absolute eosinophil count had been 170 +- 168/mm_3, and eosinophilia (more than 500/mm_3) had been observed in 11 cases (5.5%). Postirradiation eosinophilia occurred in 126 cases (63%). The mean period between institution of irradiation and the peak of the eosinophil count was 27.8 days. The mean highest eosinophil count was 691 +- 437/mm_3, and the mean bone marrow dose in this period was 906 rad. Comparisons of the eosinophil count according to the stage showed no significant differences. (Chiba, N.).
In the CERN approach to the design of a neutrino factory, the repetition frequency of the proton beam is high enough to consider stationary solid targets as a viable solution for multi-MW beams. The target consists of high density tantalum spheres of 2 mm diameter which can efficiently be cooled by passing a high mass flow He-gas stream through the voids between the Ta-granules. Very small thermal shocks and stresses will arise in this fine grained structure due to the relatively long burst of 3.3 ms from the SPL-proton linac. In a quadruple target system where each target receives only one quarter of the total beam power of 4 MW, conservative temperature levels and adequate lifetimes of the target are estimated in its very high radiation environment. A conceptual design of the integration of the target into the magnetic horn-pion-collector is presented.
The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for odd-even nuclides, but ...
Radioisotopes of Pb(II) have been of some interest in radioimmunotherapy and radioimmunoimaging (RII). However, the absence of a kinetically stable bifunctional chelating agent for Pb(II) has hampered its use for these applications. {sup 203}Pb (T{sub 1/2}=52.02 h) has application potential in RII, with a {gamma}-emission that is ideal for single photon emission computerized tomography, whereas {sup 212}Pb (T{sub 1/2}=10 h) is a source of highly cytotoxic {alpha}-particles via its decay to its {sup 212}Bi (T{sub 1/2}=60 min) daughter. The synthesis of the novel bifunctional chelating agent 2-(4-isothiocyanotobenzyl)-1,4,7,10-tetraaza-1,4,7,10-tetra-(2-carbamoyl methyl)-cyclododecane (4-NCS-Bz-TCMC) is reported herein. The Pb[TCMC]{sup 2+} complex was less labile to metal ion release than Pb[DOTA]{sup 2-} at pH 3.5 and below in isotopic exchange experiments. In addition to increased stability to Pb{sup 2+} ion release at low pH, the bifunctional TCMC ligand was ...
Radioisotopes of Pb(II) have been of some interest in radioimmunotherapy and radioimmunoimaging (RII). However, the absence of a kinetically stable bifunctional chelating agent for Pb(II) has hampered its use for these applications. "2"0"3Pb (T_1_/_2=52.02 h) has application potential in RII, with a #gamma#-emission that is ideal for single photon emission computerized tomography, whereas "2"1"2Pb (T_1_/_2=10 h) is a source of highly cytotoxic #alpha#-particles via its decay to its "2"1"2Bi (T_1_/_2=60 min) daughter. The synthesis of the novel bifunctional chelating agent 2-(4-isothiocyanotobenzyl)-1,4,7,10-tetraaza-1,4,7,10-tetra-(2-carbamoyl methyl)-cyclododecane (4-NCS-Bz-TCMC) is reported herein. The Pb[TCMC]"2"+ complex was less labile to metal ion release than Pb[DOTA]"2"- at pH 3.5 and below in isotopic exchange experiments. In addition to increased stability to Pb"2"+ ion release at low pH, the bifunctional TCMC ligand was found to have many other ...
Independent isomeric yield ratios of {sup 131}Te, {sup 133}Te and {sup 134}I have been determined at five different energies in the range of 25-44 MeV alphaparticle induced fission of {sup 238}U using radiochemical and gamma spectrometric techniques. From the independent isomeric yield ratios, fragment angular momenta (J{sub rms}) have been deduced using a statistical model analysis. The J{sub rms} were also calculated theoretically based on thermal equilibration of various collective modes after considering the occurrence of multichance fission. These data and the literature data for various fragments in the mass region 126-136 in {sup 238}U ({alpha},f), {sup 238}U (p,f) and {sup 238}U ({gamma},f) show the following important features: (i) Both the entrance channel excitation energy and input angular momentum affect the fragment angular momentum in the exit channel. (ii) There are two groups of fission products from the point of view of ...
The high spin fraction (HSF) of {sup 131}Te as a function of fragment emission angle has been determined in the 40 MeV alpha-particle induced fission of {sup 238}U using off-line gamma ray spectrometric technique. From the HSF the fragment average spin (J{sub av}) of fission product has been deduced using statistical model analysis. The J{sub av} value of {sup 131}Te is seen to remain nearly constant (10{Dirac_h}) from 90 deg. to 20 deg. On the other hand, the J{sub av} value of {sup 132}I from earlier work shows a drastic decrease (33%) from 11.4{Dirac_h} at 90 deg. to 7.6{Dirac_h} at 20 deg. . However, the yield weighted J{sub av} value of both the products show a decrease of 13%, which in close agreement with the value of 5-10% change from 90 deg. to 0 deg. in the results obtained from gamma ray multiplicity measurements. Thus the drastic difference in the change of fragment average spin (J{sub av}) of individual product from 90 deg. to 20 deg. obtained from the ...
An extensive series of pulse height measurements have been performed in partially depleted Si surface barrier detectors, using various heavy ions (Li, B, C, O, Al and Cl), at energies between 5 and 70 MeV. After correcting for the small energy loss of the incident ions in traversing the gold surface barrier layer of the detector and for the residual nuclear stopping, the resulting pulse heights per MeV for the various heavy ions were found to be up to 2.5% larger than for the {sup 241}Am (5.486 MeV) alphaparticle. This increase, although significant, is smaller than had been anticipated from an extrapolation of the earlier study of H, He and Li pulse heights by Lennard et al.. A new method of analysis of pulse height data, which significantly reduces the uncertainties associated with the dead layer energy loss and nuclear stopping corrections, was used in order to determine directly the variation of the average energy for electron-hole pair ...
A technique involving shifting of core fuel loadings was investigated as a method for reducing the neutron flux at points of high damage accumulation in the pressure vessel wall of a light water reactor. Calculations were run for six types of commercial generic PWR. Information is provided on the progress being made to develop and apply the Solid State Track Recorder (SSTR) method for in-situ in- and ex-vessel measurements of neutron exposure parameter values, such as fluence (E > 1.0 MeV) and dpa in iron. A new technique of quantitative track counting, the Buffon needle method, is advanced. It is based on random sampling of the SSTR surface. A desensitized etching technique was developed that resulted in an excellent differential energy response for alphaparticles in the 3- to 14-MeV energy range. The optical efficiency of Muscovite mica for manual fission track counting is being redetermined to form a data base for comparison with ...
Strain-controlled fatigue experiments under simultaneous irradiation have been performed to investigate the specific loadings of structural materials in next-step fusion devices. All irradiations were done on specimens made of the tempered ferritic/martensitic Cr steel MANET-I at 420 C using a 104 MeV [alpha]-particle beam. Continuous push-pull cycling (R=-1) has been applied with total strain ranges [Delta][epsilon][sub t] between 0.5 and 1.0%. Under in-beam conditions at e.g. [Delta][epsilon][sub t]= 0.5% a number of cycles to failure of N[sub f]=42000, a He concentration of 400 appm and a damage dose of 1.6 dpa has been reached. This N[sub f] is by about a factor of two below the average N[sub f]-value of unirradiated reference tests, but seven times higher than N[sub f] of comparable postirradiated specimens. It was found, that at least at 420 C conventional postirradiation tests are a conservative approach to in-situ conditions, and that in strain-controlled ...
This paper describes a reactor design to facilitate a room-temperature nuclear fusion/fission reaction to generate heat without generating unwanted neutrons, gamma rays, tritium, or other radioactive products. The room-temperature fusion/fission reaction involves the sequential triggering of billions of single-molecule, "6LiD 'fusion energy pellets' distributed in lattices of a palladium ion accumulator that also acts as a catalyst to produce the molecules of "6LiD from a solution comprising D_2O, "6LiOD with D_2 gas bubbling through it. The D_2 gas is the source of the negative deuterium ions in the "6LiD molecules. The next step is to trigger a first nuclear fusion/fission reaction of some of the "6LiD molecules, according to the well-known nuclear reaction: "6Li + D #-># 2"4He + 22.4 MeV. The highly energetic alphaparticles ("4He nuclei) generated by this nuclear reaction within the palladium will cause shock and vibrations in the ...
Using conventional deep level transient spectroscopy (DLTS), we have characterized the defects introduced in OMVPE n-GaAs at 15 K by 5.4 MeV alphaparticle irradiation from an americium 241 radio-nuclide. After this low temperature irradiation two new defects not yet reported for alpha irradiated GaAs before, E[alpha]7 and E[alpha]9, were detected 0.07 eV and 0.19 eV below the conduction band, respectively. The introduction rates of E[alpha]7 and E[alpha]9 are calculated to be 41 cm[sup -1] and 187 cm[sup -1] respectively. It was observed that both defects obeyed first order annealing kinetics, with E[alpha]9 being removed at 225 K and E[alpha]7 at 245 K corresponding to the well known stage I annealing region. The annealing rate of E[alpha]7 corresponds to an activation energy of 0.86 eV, with a pre-exponential factor of 1.0 x 10[sup 15]s[sup -1]; and the removal of E[alpha]9 has an activation energy of 0.88 eV and a pre-exponential factor of ...
Element 97 was first produced in December 1949, by the bombardment of americium-241 with accelerated alphaparticles. This new element was named berkelium (Bk) after Berkeley, California, the city of its discovery (Thompson, Ghiorso, and Seaborg, Phys. Rev. 77, 838 (1950); 80, 781 (1950)). In the 36 years since the discovery of Bk, a substantial amount of knowledge concerning the physicochemical properties of this relatively scarce transplutonium element has been acquired. All of the Bk isotopes of mass numbers 240 and 242 through 251 are presently known, but only berkelium-249 (..beta../sup -/ decay, 0.125 MeV, t/sub 1/2/ = 325 days) is available in sufficient quantities for bulk chemical studies. About 0.7 gram of this isotope has been isolated at the HFIR/TRU Complex in Oak Ridge, Tennessee in the last 18 years. Over the same time period, the scale of experimental work using berkelium-249 has increased from the tracer level to bulk studies ...
Measurements with 240 MeV {alpha} particle inelastic scattering with excellent peak/background ratios at small scattering angles including 0{degrees} were made on {sup 56}Fe and {sup 58}Ni using the multipole-dipole-multipole spectrometer at Texas A&M University. Beam was delivered to the spectrometer through a beam analysis system having two bends of 88{degrees} and 87{degrees} respectively. A slit placed after the first 88{degrees} bend was used to define the beam. Slits placed after the second bend (87{degrees}) were used to eliminate slit scattered particles. Comparison of the results of a multiple peak fit to the{sup 58}Ni spectra after continuum subtraction to DWBA calculations revealed about 32% of the E0 EWSR and 58% of the E2 EWSR in the peak, in agreement with previous works. Fits to the angular distribution of the continuum for E{sub x} = 25 MeV show that <15% of the E0 EWSR is present in the continuum. Hence 50% of the EO ...
The use of absorbable polyglactin 910 mesh (Vicryl) is described in a case of Ewing's sarcoma of the pelvis. An operation was performed to hold the small bowel and colon out of the pelvis for a temporary period during which radical radiotherapy was delivered. The mesh allowed the temporary displacement of bowel and obviated bowel radiation morbidity. (author).
Purpose: To evaluate the results of radiotherapy in cholangiocarcinoma patients managed with various combinations of chemotherapy and surgical resection with selective liver transplantation. Methods and Materials: From January 1990 to December 1995, 61 patients with histologically confirmed biliary duct adenocarcinoma were seen in the Radiation Oncology Department of the University of Pittsburgh. Median follow-up was 22 months (1 to 91 months). The extent of surgery was complete resection in 23 patients (including 17 with orthotopic liver transplant), partial resection in 4, and biopsy in 34. All patients had radiotherapy; median dose was 49.5 Gy. Thirty patients received chemotherapy: 5-fluorouracil (5-FU)-leucovorin with interferon alpha (IFN#alpha#) in 27, and taxol in 3. Results: The median survival was 20 months (95% CI 15-25 months). The 5-year actuarial survival was 23.8 #+-# 6.8%. The only significant variable in multivariate analysis ...
The document, based on European guidelines, was jointly developed by radiation oncologists, radiation physicists and radiation technologists. It contains the aims of the guidelines, professional profiles, roles and responsibilities, personnel and equipment requirements, procedures.
Hyperthermia (HT) is a strong adjuvant treatment with radiotherapy and chemotherapy because it causes tumor reoxygenation. However, the detailed molecular mechanisms of how HT enhances tumor oxygenation...Full Text Available
33 patients with advanced malignant melanoma were studied after intravenous administration of 131I-labeled Fab fragments specific for p97, an oncofetal glycoprotein of human melanoma. In all, 47 gamma...Full Text Available
Background and Purpose: In an earlier phase II study, irradiation together with razoxane was shown to improve local control in recurrent rectal cancer. Therefore, the Austrian Society of Radiooncology (OeGRO) initiated a randomized controlled trial in 1992 to compare this combined treatment versus radiation therapy alone. Patients and Methods: Between 1992 and 1999, 36 patients with localized recurrences of rectal cancer were randomized to receive radiotherapy without (group A) or with razoxane (group B). The prognostic variables of the two groups were similar except for a longer median latency period from initial surgery to local recurrence in group A. High-energy photons with daily fractions between 170 and 200 cGy were used. The median total radiation dose was 60 Gy in each group. The patients in group B received a median razoxane dose of 9.6 g (range, 5-12 g). Main outcome measures were local control, overall survival, and toxicity. Results: The combined ...
A review of main issues in diagnosing, complex treatment and prognosis of Ewing's sarcoma is presented. Current trend in chemotherapy, radiotherapy and surgery of the disease is discussed. Unfavourable prognosis is attributed to the systematic character of the disease, necessitating a complex therapeutic approach. Attempts to make an optimal combination of the three therapeutic methods in order to improve survival and reduce the rate of post-treatment complications are analyzed. 37 refs., 4 tabs. (author).
The purpose of this study was to investigate if interfraction and intrafraction motion in free-breathing and gated lung IMRT can lead to systematic dose differences between 3DCT and 4DCT. Dosimetric...Full Text Available
PurposeRTOG protocol 95-17 was a phase I/II trial to evaluate multi-catheter brachytherapy as the sole method of adjuvant breast radiotherapy for stage I/II breast...Full Text Available
Electron beam therapy applied to a lymph node metastasis from a squamous cell carcinoma was followed by the development of histologically and immunologically typical bullous pemphigoid, the lesions being initially strictly confined to the irradiation area. This observation suggests that the bullous pemphigoid antigen may be altered or unmasked by electron beam radiotherapy, leading subsequently to the production of autoantibodies. The disease in this case effectively responded to the administration of tetracycline and niacinamide, a therapeutic regimen described recently.
An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).
In order to consider some procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions and in accordance with information contained in international reports elaborated by International Atomic Energy Agency (IAEA) and of the data base availability by the European group Radiation Oncology Safety Information System (ROSIS) on the events, a research of the occurred errors was performed. For the evaluation of the incidents a data base based in the ROSIS and added plus a parameter was created 'type of error'. All the stored data make possible the evaluation of the 839 incidents in terms of frequency of the type of error, the process of detention, the number of reached patients and the degree of severity. Of the 50 types of found errors, the type of error more frequently was 'incorrect treatment coordinate', confirmed with the data of literature and representing 28,96 por cent of the total of the ...
PurposeWe conducted a comparative study of Clinical Target Volume (CTV) definition of pelvic lymph nodes by multiple GU radiation oncologists looking at the levels...Full Text Available
To capitalize on the response of tumor cells to ionizing radiation, we developed a controlled-release nanoparticle drug delivery system using a targeting peptide that recognizes a radiation-induced...Full Text Available
The role of IGF-I in the negative regulation of GH expression and release is demonstrated by in vitro and in vivo models; however, the targets and mechanisms of IGF-I...Full Text Available
The technology of gene targeting through homologous recombination has been extremely useful for elucidating gene functions in mice. The application of this technology was thought impossible in the large...Full Text Available
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
... detected (and reported) as a by-product of MRM screening (MS/MS) targeted by Law or Rule ... detected (and reported) as a by-product of MRM screening (MS/MS) targeted by Law or Rule ...
The phenomenon of antibiotic resistance has created a need for the development of novel antibiotic classes with non-classical cellular targets. Unfortunately, target-based drug discovery against...Full Text Available
Many genetic processes depend on proteins interacting with specific sequences on DNA. Despite the large excess of nonspecific DNA in the cell, proteins can locate their targets rapidly. After initial...Full Text Available
Peroxisomes, glyoxysomes, glycosomes, and hydrogenosomes have each been classified as microbodies, i.e., subcellular organelles with an electron-dense matrix that is bound by a single membrane. We investigated...Full Text Available
Considering accessibility of the 3′UTR is believed to increase the precision of microRNA target predictions. We show that, contrary to common belief, ranking by the hybridization energy or by...Full Text Available
Histone Arg methylation and Lys acetylation have been found to cooperatively regulate the expression of p53 target genes. Peptidylarginine deiminase 4 (PAD4) is an enzyme that citrullinates...Full Text Available
Operant conditioning techniques were applied to the study of how target fixations are controlled by the probability of signal occurrence. In a standard vigilance setting, gaze at three illuminable...Full Text Available
Cytokinesis in animal and fungal cells utilizes a contractile actomyosin ring (AMR). However, how myosin II is targeted to the division site and promotes AMR assembly, and how the AMR coordinates with...Full Text Available
Purposes1. To determine the optimal pelvic nodal clinical target volume for post-operative treatment of endometrial cancer. 2. To compare the DVH of different treatment planning...Full Text Available
... they assisted in the 2000 attack on the USS Cole? ... List the types of targets that ETA has attacked. ... was at least partially responsible for the attack. ...
... Tanzania, and the attack on the USS COLE. ... vis another has no bearing on the legality of the attack. If the person attacked is a combatant, the use of ...
The production of polarized negative ion beams by collisional pumping is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.
The production of polarized negative ion beams by ''collisional pumping'' is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.
While there is growing interest in Real Time Pricing as a competitive tool, its adoption to date has been constrained by wariness on the part of many utilities and many of their customers. That wariness is not misplaced, for Real Time Pricing is not for everyone. In order for both utilities and their customers to benefit, the pricing system must be properly tailored for, and offered to, the appropriate audience. This paper discusses needs for identifying targets, implications of targeting of Real Time Pricing to various types of customers, and implications for design and marketing of such pricing systems. Examples from utility experiences are provided, and recommendations are offered for development of improved targeting of Real Time Pricing.
This paper present the results of a series of calculations made to determine the "2"3"8Pu production potential of several advanced target assembly designs in the Fast Flux Test Facility (FFTF). These calculations show that by using advanced target designs the intimately mix the "2"3"7Np target material with an yttrium hydride moderator, the FFTF has the potential of producing up to 30 kg of high-quality "2"3"8Pu per year.
We apply the framework developed in Target space duality I: general theory. We show that both nonabelian duality and Poisson-Lie duality are examples of the general theory. We propose how the formalism leads to a systematic study of duality by studying few scenarios that lead to open questions in the theory of Lie algebras. We present evidence that there are probably new examples of irreducible target space duality.
The gastrin releasing peptide (GRP) receptor is becoming an increasingly attractive target for development of new radiolabeled peptides with diagnostic and therapeutic potential. The attractiveness of the GRP receptor as a target is based upon the functional expression of GRP receptors in several tumors of neuroendocrine origin including prostate, breast, and small cell lung cancer. This concise review outlines some of the efforts currently underway to develop new GRP receptor specific radiopharmaceuticals by employing a variety of radiometal chelation systems.
This paper illustrates how the techniques developed by the authors for capital cost targeting of mass exchange networks can be applied to determination of capital investment targets for reduction in effluent for existing systems involving mass exchange. The results is an impact diagram which shows the relationship between effluent reduction and capital investment, indicating a region of limiting return on investment as well as the maximum possible reduction in effluent. (au)
In order to facilitate observations of low energy nuclear reactions, a new type recoil mass-separator together with a new gas-jet target system is being developed at the tandem accelerator facility in Kyushu University. The expected mass-resolving power of the separator is 220 for a solid angle of 10 msr and the practical thickness of the gas-jet target will exceed 0.1 atm#centre dot#cm for the light elements of H and He. (author).
A portable fiber optic detector that senses the presence of specific target chemicals by electrostatically attracting the target chemical to an aromatic compound coating on an optical fiber. Attaching the target chemical to the coated fiber reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.
A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical ...
...2010-10-01 2010-10-01 false Energy Policy Act target group certification...Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND FORMS SOLICITATION...Provisions and Clauses 952.226-73 Energy Policy Act target group...
Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit ...
Target materials for inertial fusion energy (IFE) power plant designs might be selected for a wide variety of reasons including wall absorption of driver energy, material opacity, cost and ease of fabrication. While each of these issues are of great importance, target materials should also be selected based upon their safety and environmental (S and E) characteristics. The present work focuses on the recycling, waste management and accident dose characteristics of potential target materials. If target materials are recycled so that the quantity is small, isotopic separation may be economically viable. Therefore, calculations have been completed for all stable isotopes for all elements from lithium to polonium. The results of these calculations are used to identify specific isotopes and elements that are most likely to be offensive as well as those most likely to be acceptable in terms of their S and E ...
Certain allelochemicals of the marine dinoflagellate Alexandrium tamarense cause lysis of a broad spectrum of target protist cells but the lytic mechanism is poorly defined. We first hypothesized that membrane sterols serve as molecular targets of these lytic compounds, and that differences in sterol composition among donor and target cells may cause insensitivity of Alexandrium and sensitivity of targets to lytic compounds. We investigated Ca^2^+ influx after application of lytic fractions to a model cell line PC12 derived from a pheochromocytoma of the rat adrenal medulla to establish how the lytic compounds affect ion flux associated with lysis of target membranes. The lytic compounds increased permeability of the cell membrane for Ca^2^+ ions even during blockade of Ca^2^+ channels wit...
The modeling methods used to compute the neutron-induced activation of target and near-target materials in the NIF facility are presented. A detailed space and energy description of the neutron environment in the different materials is provided. A new capability has been developed to treat in a general way the activation of debris produced in an operational regime of yield and no-yield experiments. First calculations are addressed to analyze the activity of the debris into the target chamber. The contribution of the different components to activity, interior dose rates, and waste disposal rating (WDR) is determined. The importance of the activation coming from primary irradiation in the target, and from secondary irradiation in debris deposited onto the first wall is assessed. Finally, waste hazards of the activated debris when removed out of the chamber and stored are analyzed. (authors)
The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of radiation. This justifies establishing a somatically significant dose, SSD. The reduction ...
Purpose: To report outcomes of a single institution study of stereotactic body radiotherapy (SBRT) for unresectable cholangiocarcinoma. The dose-volume dependency of the observed gastrointestinal toxicity is explored. Methods and materials: Twenty-seven patients with unresectable cholangiocarcinoma (n = 26 Klatskin tumours and one intrahepatic cholangiocarcinoma (IHCC)) were treated by linac-based SBRT. The dose schedule was 45 Gy in three fractions prescribed to the isocenter. Results: The median progression-free survival and overall survival were 6.7 and 10.6 months, respectively. With a median follow-up of 5.4 years, 6 patients had severe duodenal/pyloric ulceration and 3 patients developed duodenal stenosis. Duodenal radiation exposure was higher in patients developing moderate to high-grade gastrointestinal toxicity with the difference in mean maximum dose to 1 cm"3 of duodenum reaching statistical significance. A statistically significant association between ...
Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, 600 rads at a time, 3600 - 4200 rads in total is applied by 8 MeV electron twice a week method. 2) For malignant melanoma, 1000 rads at a time, ...
To define the prognostic factors after surgical resection and evaluate the effectiveness of Post Operative Radiotherapy (PORT) in cases with cholangiocarcinoma, 44 cases with proximal cholangiocarcinoma were examined. The mean observation period was 20.6 months, and the survival rates 1, 3 and 5 years after the resection were 79.9%, 59.8% and 39.3%, respectively. Univariate analysis revealed that the presence of lymph node metastasis and absence of PORT were significant poor prognostic factors. Multivariate analysis revealed that the absence of PORT was a significant poor prognostic factor. The survival rates for 1 and 3 years after the resection were 80.0% and 40.0% in the curable A/B and PORT (-) group, and 100% and 53.3% in curable C and PORT (+) group. There were no local reccurences in the pathologically classified hm2 and em2 patients who underwent PORT. Even when the surgical margin is positive for the carcinoma pathologically, it is possible to avoid local ...
Dose measurements were performed in several body regions of patients suffering from inflammatory degenerative diseases (humeral epicondylitis, humeroscapular periarthritis, gonarthrosis, axillary hidradenitis, rheumatoid arthritis, coxarthrosis, parotitis). The problem of the radiation induction of neoplasms is predominant concerning somatic as well as genetic risk, discussed by example of the most frequently occurring organ cancer. Compared to the rate of breast cancer in the highly developed industrial states (5,000 to 6,000 cancers/100,000 women) the 'radiation induction' calculated according to a mathematical model of ICRP 26 (1.25 cases of death for breast cancers/100,000 women following for example irradiation of epicondylitis) is behind several powers of ten and not demonstrable. The genetic radiation exposure is also low. Derived from the measurements it is wrong to give up reliable and approved indications of radiotherapy of non-malignant diseases because ...
The present study was undertaken in 27 children with localized Ewing's sarcoma treated at our hospital. In 9 cases the lesion was central and in 18 peripheral. Treatment consisted of: 1) Chemotherapy with 6 drugs (vincristine, cyclophosphamide, methotrexate, bleomycin, dactinomycin and doxorubicin) for one year in all patients; 2) Radiotherapy in 24 patients at a dose of 30-40 Gy in the entire bone with a booster dose of 10-15 Gy in the lesion. In 7 patients debulking surgery was performed followed by irradiation. Two cases with tumor in expendable bones and one with extensive destructive lesion in the tibia underwent radical surgery. One patient suffered local recurrence (femur) and 6 developed distant metastases. The remaining 20 (74%) patients were alive and tumor-free after follow-up periods of 17-80 months. Among the 12 patients with extremity lesions who were alive, 7 (58%) had minimal or mild treatment sequelae, 2 moderate, and 3 severe sequelae but no ...
This study examines some radiation accidents occurred in the past. This information has been systematically assessed to get global lessons. The experience feedback shows that the most of accidents happened in certain conditions. These conditions can be distributed in four categories: 1- perception and vigilance in occupation: accidental exposure happened by lack of vigilance in details and lack of vigilance and perception; 2- procedures: accidental exposure happened following a lack of procedures or control that were not enough complete, not enough documented or not completely implemented; 3- training and understanding: accidental exposures happened because the personnel was not enough qualified and educated, did not get the general training nor the the necessary specialized training; 4- liabilities: accidental exposures happened following lacks and ambiguity in the definition of functions of the personnel and in the hierarchy liabilities. In these precise cases the safety tasks have ...
The purpose of this study was to determine the optimal technique for delivering postoperative radiotherapy for vulvar cancer and other tumors requiring treatment of the inguinal nodes. This project compared tumor coverage and normal tissue sparing for the 5 main radiotherapy techniques that are used to treat vulvar cancer. The intensity-modulated radiation therapy (IMRT) plan was undesirable because it resulted in an excessive dose to portions of the central pelvic structures. The photon thunderbird with skin match was unacceptable because it underdosed a portion of the groin region. The electron thunderbird was ideal for thin patients but was not applicable for most patients because of excessive dose to the skin and subcutaneous tissues. The photon through-and-through and the photon thunderbird with deep match were acceptable in most situations. In thin patients, where the depth of the inguinal vessels is less than 3 cm, the electron ...
From December 1981 to September 1986, 149 patients were treated at the Radiotherapy Department of the Hospital Clinico y Provincial of Barcelona by means of intracavity irradiation with 137 cesium high 1 sources and 2. To 112 of the total number of patients external radiotherapy to the whole of the pelvis using photons of 6 MeV was also administered. A total of 46 (30.7%) patients presented rectal complications. The rectitis observed was mild in 16 cases (10.7%), moderate in 15(10%) and severe in 15(10%). The 15 patients with severe rectitis had to be treated by unloading colostomy. In patients with severe complications, the maximum total rectal dose administered was between 5,855 and 9,490 cGy, and the maximum rectal dose administered via curietherapy was 1,055 to 7,320 cGy. Maximum total rectal dose administration greater than 4,000 cGy and maximum rectal dose administered via curietherapy greater than 5,800 cGy were statistically significant ...
In 1981, the German Society of Pediatric Oncology initiated a multi-institutional study for the treatment of Ewing's sarcoma. The protocol (Cooperative Ewing's Sarcoma Study, CESS 81) consisted of four courses of a four-drug-regimen (VACA), each course taking nine weeks. Local therapy (radical surgery or resection plus irradiation or radiotherapy alone) was performed after the second course. The results of CESS 81 can be summarized as follows: VACA-chemotherapy is effective in controlling systemic disease. Initial tumor mass and response to initial chemotherapy are of major prognostic value for local control and survival. Permanent local control is a problem, especially in irradiated patients. The high local failure rate in irradiated patients in CESS 81 could be attributable to the following reasons: Late start of local therapy (after 18 weeks of chemotherapy), uneven distribution of prognostic parameters: Large tumors were more often irradiated than operated, ...
From 1964 to 1973 at the Institute of Oncology and Radiobiology, Havana City, 18 clinical histories were studied, all of them from patients with Erwing's sarcoma, histologically diagnosticated by biopsy. Age, sex, race, traumatism background, hemogram disturbances, radiographic signs, primary tumor localization, and early treatment, were exposed. Early treatment in 14(83%) patients as radiotherapy. Local recurrence or metastasis was presented in 10(55,5%) patients during the two first years following attack treatment. Five (35,7%) patients was the survival rate within five years starting early treatemt. After five years, three (21,4%) patients were alive: for 18 and 14 year, and 64 month period; two patients died at 62 and 64 months. It is concluded that this survival may be increased by initial behaviour enclosed at the technologic therapeutic patterns of the the Institute of Oncology and Radiobiology, of Havana City. (author).
The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)
Over 300 cases of femoral neck fractures following radiotherapy for intrapelvic malignant tumor have been reported in various countries since Baensch reported this disease in 1927. In Japan, 40 cases or so have been reported, and cases of bilateral femoral neck fractures have not reached to ten cases. The authors experienced a case of 75 year-old female who received radiotherapy for cancer of the uterus, and suffered from right femoral neck fracture 3 months after and left femoral neck fracture one year and half after. As clinical symptoms, she had not previous history of trauma in bilateral femurs, but she complained of a pain in a hip joint and of gait disturbance. The pain in left femoral neck continued for about one month before fracture was recognized with roentgenogram. As histopathological findings, increase of fat marrow, decrease of bone trabeculae, and its marked degeneration were recognized. Proliferation of some blood vessels was ...
Using static Michelson interferometer to get the spectrum information of measurement targets for spectrum identification, under the condition that the interference length is constant, the system can be optimized by BP neural network algorithm for the mixed spectral separation process. Thereby it can realize improving the recognition probability of camouflage target. Collecting the spectrum information in field of view (FOV) by the interferometer and linear array CCD detector, composing the set of mixed spectrum data, with known absorption spectrum of the material as a hidden layer of rules, it used BP neural network to separate the mixed spectrum data. Experiment with different distances, different combinations of mixed background spectrum as the initial data, using steel target (size: 1.5 m x 1.5 m) made of four kinds, the recognition probability of non-camouflage target is about 90% by BP neural ...
In the Fourth Dutch National Environmental Outlook (NMP, abbreviated in Dutch) of the National Institute of Public Health and the Environment (VROM), published in July 1997, possible future developments in the traffic and transport sector in the Netherlands are described for the period 1995-2020 and also evaluates present Dutch policies. NMP-4 also offers possible solutions for expected environmental problems. This report serves as a background document for the traffic and transport sector. With a view to present Dutch policies, the main conclusions drawn from the Outlook are that: (1) the policy targets for car and lorry use for 2010 will not be met, (2) the target for CO2 emissions from road transport for 2010 will not be met, (3) the NOx emission target for 2010 will be met for cars, but not for trucks, (4) the VOC emission target for 2010 will be met for cars, but not for trucks, and (5) the noise ...
This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers and physicians. (author)
A simple and cheap method is described for the manufacturing of individual positioning aids made of foamed polyurethane. Some examples are given to demonstrate the applicability of these positioning aids for the irradiation of different body regions. The reproducibility of the radiation field in the head and neck area was investigated with and without positioning aid. It was proved that the field is adjusted more exactly when positioning aids are applied. The dosimetric investigations performed showed a negligible influence of foamed polyurethane on the radiation quality. So the positioning aids could be left within the radiation field when drawing the field borders.
Oral mucositis associated with head and neck radiotherapy can substantially hinder completion of cancer therapy. Alleviation of this often severe stomatitis can provide enhanced patient comfort and facilitate appropriate care. A double-blind format was used in a pilot project to measure, against a control rinse, the effectiveness of an oral rinse consisting of hydrocortisone, nystatin, tetracycline, and diphenhydramine in controlling radiation-related mucositis. A combination of clinical evaluation and patient responses to a questionnaire was used to judge the results of the topical medications. Patients using the experimental medication developed less mucositis than did patients in the control group.
A compact medical synchrotron is being developed which aims to promote the advanced radiotherapy based on the accelerator. As it is small-sized, a high field dipole magnet of 3 T at 200 kA is used. It is excited by the discharge current of the capacitor bank of which waveform is half sinusoidal. To provide with the flat field of 10 - 20 #mu#s duration for the multi-turn injection an additional power supply is developed. For the quadrupole magnet a 100 kHz switch-mode power supply is adopted as it requires the fine tuning and accurate field tracking to the dipole field. (author)