WorldWideScience
1

A duplex real-time RT-PCR assay for the detection of California serogroup and Cache Valley viruses  

UK PubMed Central (United Kingdom)

A duplex TaqMan real-time RT-PCR assay was developed for the detection of California (CAL) serogroup viruses and Cache Valley virus (CVV), for use in human surveillance. The targets selected...Full Text Available

2009-10-01

2

One-step RNA pathogen detection with reverse transcriptase activity of a mutated thermostable Thermus aquaticus DNA polymerase.  

Science.gov (United States)

We describe the cloning and characterization of a mutated thermostable DNA polymerase from Thermus aquaticus (Taq) that exhibits an increased reverse transcriptase activity and is therefore designated for one-step PCR pathogen detection using established real-time detection methods. We demonstrate that this Taq polymerase mutant (Taq M1) has similar PCR sensitivity and nuclease activity as the respective Taq wild-type DNA polymerase. In addition, and in marked contrast to the wild-type, Taq M1 exhibits a significantly increased reverse transcriptase activity especially at high temperatures (>60 degrees C). RNA generally hosts highly stable secondary structure motifs, such as hairpins and G-quadruplexes, which complicate, or in the worst case obviate, reverse transcription (RT). Thus, RT at high temperatures is desired to weaken or melt secondary structure motifs. To demonstrate the ability of Taq M1 ...

2010-02-01

3

Digital processing to improve image quality in real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively.

1985-01-01

4

Digital processing to improve image quality in real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively. (orig.).

1985-01-01

5

Model Checking Real Time Java Using Java PathFinder  

Science.gov (United States)

The Real Time Specification for Java (RTSJ) is an augmentation of Java for real time applications of

2005-01-01

6

One-step RNA pathogen detection with reverse transcriptase activity of a mutated thermostable Thermus aquaticus DNA polymerase  

British Library Electronic Table of Contents (United Kingdom)

We describe the cloning and characterization of a mutated thermostable DNA polymerase from Thermus aquaticus (Taq) that exhibits an increased reverse transcriptase activity and is therefore designated for one-step PCR pathogen detection using established real-time detection methods. We demonstrate that this Taq polymerase mutant (Taq M1) has similar PCR sensitivity and nuclease activity as the respective Taq wild-type DNA polymerase. In addition, and in marked contrast to the wild-type, Taq M1 exhibits a significantly increased reverse transcriptase activity especially at high temperatures (>60degreeC). RNA generally hosts highly stable secondary structure motifs, such as hairpins and G-quadruplexes, which complicate, or in the worst case obviate, reverse transcription (RT). Thus, RT at hi...

2010-01-01

7

Kinetics of gypsum crystal growth on a reverse osmosis membrane  

British Library Electronic Table of Contents (United Kingdom)

The development of calcium sulfate dihydrate (gypsum) mineral scale in reverse osmosis (RO) membrane desalting was investigated by direct real-time observation of crystal growth. Gypsum scaling studies were conducted in a specially modified plate-and-frame reverse osmosis cell fitted with an optical window, with dark-field membrane lighting arrangement within the membrane cell to enhance crystal boundaries and allow recording of digital surface images magnified through an optical microscope. The evolution of the surface number density (SND) of gypsum crystals resembled a sigmoidal population growth process with an increasing rate of crystal formation at higher solution supersaturation (with respect to gypsum) at the membrane surface. The rate of formation of new crystals declined as the su...

2008-01-01

10

Time-resolved triple-axis spectroscopy - a new method for real-time neutron scattering  

International Nuclear Information System (INIS)

A new method for kinetic experiments with neutrons is described. This method combines the conventional triple-axis neutron spectroscopy with relaxation-type experiments. Whereas the former method yields information about the microscopic dynamics of solids, the latter provides macroscopic relaxation times. The combination of both methods allows to determine the microscopic mechanism of relaxation processes. The time-resolved triple-axis spectroscopy is limited to reversible processes and to time scales from 10"-"3 to 10"4 s. Typical applications are the kinetics of phase transformations (structural and dynamical changes), kinetics of domain distributions, kinetics of (spinodal) decomposition, reversible solid state reactions, time-dependent occupation of phonon states or phonon lifetimes. (orig.).

1990-04-01

11

Hsp90 gene, an additional target for discrimination between the potato cyst nematodes, Globodera rostochiensis and G. pallida, and the related species, G. tabacum tabacum  

British Library Electronic Table of Contents (United Kingdom)

The heat-shock gene, Hsp90, was targeted as a new variable genomic region to supplement other DNA-based tests for identification and discrimination of Globodera pallida, G. rostochiensis and G. tabacum tabacum. Populations of the potato cyst nematodes, G. pallida and G. rostochiensis (PCN), originating from Canada, France, Belgium and USA, together with two populations of G. tabacum tabacum from the USA and France were used for the amplification of a fragment of the Hsp90 gene. General and specific primers and probes for each species were derived from the consensus and non-consensus regions of the aligned sequences, respectively. A triplex conventional PCR assay, using a general forward and reverse or three specific reverse primers, as well as a real-time PCR using general primers and spec...

2011-01-01

12

Kinetics of the stress induced phase transition in quartz by real-time neutron scattering  

International Nuclear Information System (INIS)

Complete text of publication follows. The stability regime of the incommensurate phase of quartz is influenced by uniaxial stress. Hence, the phase transition can be induced under isothermal conditions by the application of external mechanical forces. Using real-time neutron scattering the time evolution of structural changes is investigated id detail during stress variations. The time dependent behaviour of the satellite reflection is compared with that one of the fundamental Bragg reflection which - via primary extinction - gives information about the perfection of the crystal. On increasing stress the perfection of the lattice is destroyed immediately while the modulated structure is built up with a delay of about 1 s. Decreasing the stress leads to a reverse behaviour. Moreover, there is evidence that under periodical load residual non-relaxed strain fields survive leading to a different temperature dependence as compared to static ...

1999-09-01

13

Efficient methodologies for sensitive HIV-1 RNA quantitation from plasma and vaginal secretions  

British Library Electronic Table of Contents (United Kingdom)

Background: Quantifying HIV levels in mucosal secretions is essential to study compartmentalized expression of HIV and facilitate development of intervention strategies to prevent disease progression and transmission. Objectives: To develop a sensitive, reliable, and cost-effective technique to quantify HIV from blood and vaginal secretions that is compatible with efficient implementation in clinical research environments. Study design: A sensitive, reliable, internally-controlled real-time reverse transcriptase (RT) PCR assay, which uses the HIV-1 pol gene as a target (Hpol assay) was developed to quantify HIV levels in plasma and genital secretions, and compared to the widely used Roche Amplicor(TM) HIV-1 Monitor assay. In addition, a simplified method of sample collection and processing...

2009-01-01

14

Real-time digital libraries based on widely distributed, high performance management of large-data-objects  

CERN Document Server

Real-time digital libraries based on widely distributed, high performance management of large-data-objects

1997-01-01

16

Void fraction distribution measurement in two-phase flow by real-time neutron radiography and real-time image processing  

International Nuclear Information System (INIS)

A real-time two-dimensional void fraction distribution measurement of gas-liquid two-phase flow was carried out by real-time neutron radiography and real-time image processing. The JRR-3M real-time thermal neutron radiography system and a Musashi dynamic image processing system were used. Image processing methods to calculate two-dimensional and cross-sectional void fraction distributions were proposed. The void fraction distribution was calculated by non-linear processing of the neutron radiography image and displayed by pseudo-color in real-time. A simple gas-liquid two-phase flow induced by injecting gas through needles at the bottom of water pool in a rectangular vessel was tested. (orig.).

1996-07-01

17

Market segmentation and targeting for real time pricing  

Energy Technology Data Exchange (ETDEWEB)

While there is growing interest in Real Time Pricing as a competitive tool, its adoption to date has been constrained by wariness on the part of many utilities and many of their customers. That wariness is not misplaced, for Real Time Pricing is not for everyone. In order for both utilities and their customers to benefit, the pricing system must be properly tailored for, and offered to, the appropriate audience. This paper discusses needs for identifying targets, implications of targeting of Real Time Pricing to various types of customers, and implications for design and marketing of such pricing systems. Examples from utility experiences are provided, and recommendations are offered for development of improved targeting of Real Time Pricing.

1996-03-01

18

Characteristic findings of pediatric inpatients with pandemic (H1N1) 2009 virus infection among severe and nonsevere illnesses  

British Library Electronic Table of Contents (United Kingdom)

We analyzed the clinical features of inpatients at a Japanese pediatric department who were infected with pandemic (H1N1) 2009 virus. Study participants included 46 children hospitalized from July 2009 to January 2010. Infection with the virus was confirmed using real-time reverse transcriptase polymerase chain reaction (RT-PCR). The epidemic month was October 2009; 34 patients were boys, and median age was 7?years. Pandemic influenza-associated respiratory diseases included pneumonia (n?=?42), bronchitis (n?=?3), and pharyngitis (n?=?1). The median time from onset to admission was 3?days. Children were divided into those with severe (n?=?32) versus nonsevere illnesses (n?=?14) according to Japanese guidelines. Significant features in the severe group were younger age, previous asthmatic a...

2011-01-01

19

Real-time system for processing regime diagnostic on accelerator  

International Nuclear Information System (INIS)

The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.

20

Real-time neutron beam monitor  

Energy Technology Data Exchange (ETDEWEB)

An array of multiwire proportional counters has been employed to image, in 'real-time', a collimated neutron beam produced at an electron linac facility. Test results are presented, along with a discussion of the advantages of this technique.

1983-06-15

21

Real-Time Adherence Monitoring for HIV Antiretroviral Therapy  

UK PubMed Central (United Kingdom)

Current adherence assessments typically detect missed doses long after they occur. Real-time, wireless monitoring strategies for antiretroviral therapy may provide novel opportunities to proactively...Full Text Available

2010-12-01

22

Immunoquantitative Real-Time PCR for Detection and Quantification of Staphylococcus aureus Enterotoxin B in Foods  

UK PubMed Central (United Kingdom)

A real-time immunoquantitative PCR (iqPCR) method for detection of Staphylococcus aureus enterotoxin B (SEB) was developed and evaluated using both pure cultures and foods. The assay...Full Text Available

2006-10-01

23

Detection and Differentiation of Cryptosporidium spp. in Human Clinical Samples by Use of Real-Time PCR?  

UK PubMed Central (United Kingdom)

Real-time PCR has the potential to streamline detection and identification of Cryptosporidium spp. in human clinical samples. In the present...Full Text Available

2011-03-01

24

Comparison of a Commercial Multiplex Real-Time PCR to the Cell Cytotoxicity Neutralization Assay for Diagnosis of Clostridium difficile Infections?  

UK PubMed Central (United Kingdom)

A commercial multiplex real-time PCR assay (Cepheid Xpert C. difficile assay) for the diagnosis of Clostridium difficile infection was evaluated. The sensitivity and...Full Text Available

2009-11-01

25

A real-time neutron beam monitor  

International Nuclear Information System (INIS)

An array of multiwire proportional counters has been employed to image, in 'real-time', a collimated neutron beam produced at an electron linac facility. Test results are presented, along with a discussion of the advantages of this technique. (orig.).

1983-06-01

27

WWW.NMDB.EU: The real-time neutron-monitor data-bank  

International Nuclear Information System (INIS)

German 2009 [1 p.] Germany Steigies, Christian IEAP, Christian-

2009-04-02

28

Untitled - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Directional audio technology for headphone applications is being developed. A laboratory demonstration model of a real-time digital ...

29

UNFBENJ: on-line, real-time neutron spectrum unfolding for Benjamin detectors  

International Nuclear Information System (INIS)

(Jun 1978). United States Miller, H. Univ. of Missouri, Columbia Peterman,

1978-06-18

30

Scintillation converter screen investigation for real-time neutron radiography  

International Nuclear Information System (INIS)

(1980). United States Panhuise, VE Bull, SR Seydel, JA Univ of Missouri-

1980-11-21

31

Real-time neutron radiography observations of aerosol filtration  

International Nuclear Information System (INIS)

(1984). United States Brenizer, JS McRae, DD Sulcoski, MF University

1984-11-11

32

Real-time neutron radiography at the Georgia Tech Research Reactor  

International Nuclear Information System (INIS)

(Jun 1982). United States Davis, MV Berger, H. Patricelli, F. Georgia Institute

1982-06-11

35

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor  

International Nuclear Information System (INIS)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-01

36

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-11-01

37

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

International Nuclear Information System (INIS)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-01-01

38

Two-phase fluid flow measurements in small diameter channels using real-time neutron radiography  

International Nuclear Information System (INIS)

A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)

1994-04-05

39

Principium research of real-time neutron radiography in No. 300 reactor  

International Nuclear Information System (INIS)

The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper

2002-12-01

40

COBAS AmpliPrep/COBAS TaqMan HIV-1 Test, 48 Tests COBAS AmpliPrep ...  

Science.gov (United States)

... 14. Piatak, M. Jr., Saag, MS, Yang, LC, Clark, SJ, Kappes, JC, Luk, KC, Hahn, BH ... Wei, X., Ghosh, SK, Taylor, ME, Johnson, VA, Emini, EA, Deutsch, P., Lifson, JD ...

41

A real-time routing model for hazardous materials  

Energy Technology Data Exchange (ETDEWEB)

Experiences in hazardous materials transportation show that purely strategic or planning approaches have considerable shortcomings and that real-time management must be addressed. The commercialization of advanced location and communications technology provides the basis for real-time guidance. Considering the possibilities this new technology offers, a real-time routing model is proposed. It is based on the premises that a human dispatcher must assess the impacts of sudden events on safety and transportation costs and evaluate safe and cost-effective routing alternatives. Due to high uncertainty and time constraints in this real-time environment, risks and transportation costs are expressed as preferences on an ordinal scale. The model has been integrated into a decision support system and assessed in an experimental setting. This ordinal preference model turned out to be superior to a utility approach ...

1994-06-30

42

Real time estimation of photovoltaic modules characteristics and its application to maximum power point operation  

Energy Technology Data Exchange (ETDEWEB)

In this paper, an approximate curve fitting method for photovoltaic modules is presented. The operation is based on solving a simple solar cell electrical model by a microcontroller in real time. Only four voltage and current coordinates are needed to obtain the solar module parameters and set its operation at maximum power in any conditions of illumination and temperature. Despite its simplicity, this method is suitable for low cost real time applications, as control loop reference generator in photovoltaic maximum power point circuits. The theory that supports the estimator together with simulations and experimental results are presented. (author)

2007-05-15

43

Quantitative density measurements from a real-time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-01-01

44

Quantitative density measurements from a real-time neutron radiography system  

International Nuclear Information System (INIS)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-11-16

45

Neutron radiography with the cyclotron, 5  

International Nuclear Information System (INIS)

Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).

1987-01-01

46

MTF analysis of the near-real time neutron radiography facility at MURR  

International Nuclear Information System (INIS)

Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).

1981-12-01

47

ch4  

Science.gov (United States)

Earlier studies had concluded that the preferred direction of the rocket nozzle should ..... Center had to redesign the sensor canisters, brackets and cable supports. ... depending on inspection of the quality of the incoming pictures in real-time. ...

48

The Traffic Management ... - NASA Ames Aviation Systems Division  

Science.gov (United States)

flow and changing scheulingparameters during real-time ..... illustrative purposes, only two minimum separation ..... Individual Flights and Air Traffic, AGARD. No. ...

49

Real-Time Stability and Control Derivative Extraction From F-15 - NASA  

Science.gov (United States)

and the estimated parameter covariance matrix is. 5. (25) where p in this case is the number of elements in the vector . The parameter standard errors, ?, ...

50

Real-Time Diagnostics for a Reusable Rocket Engine - NASA ...  

Science.gov (United States)

of the Intelligent Control System (ICS) for reusable rocket engines. .... the incoming measurements with corresponding estimates, a sensor failure can be ...

51

Real Time Trajectory Planning for Groups of Unmanned ...  

Science.gov (United States)

... kinematic model for the robots and designed ... theoretic approach for modeling mobile robot teamn formations". ... "UUV teams, control from a biological ...

2005-08-22

52

Power Management for Real-Time Systems  

Science.gov (United States)

... CycleSim models an IBM PowerPC 405GP system-on-a-chip and includes a cycle-accurate, event-based power model of the processor core and ...

2004-07-01

53

Neutron radiography with the cyclotron, 5. Cyclotron-based real time neutron fluoroscopy system and its application for some industrial components  

Energy Technology Data Exchange (ETDEWEB)

Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images.

1987-03-01

54

Multiprocessors and Asynchronous Event Handling in the Real-Time Specification for Java  

British Library Electronic Table of Contents (United Kingdom)

The Real-Time Specification for Java (RTSJ) is silent on multiprocessor issues. It attempts not to preclude multiprocessor implementations but provides no direct support. Many areas of the RTSJ leave an implementation considerable freedom on how it provides the defined functionality. One such area is the asynchronous event handling (AEH) model. Events are fired and associated handlers are scheduled for execution in response; handlers have defined scheduling parameters and deadlines. The primary goal of the AEH model is to support a lightweight real-time concurrency model. Hence handlers, in general, do not have dedicated threads. Rather, the implementation is responsible for ensuring that all handlers meet their deadlines. Typically real-time threads are assigned to execute handlers by the...

2011-01-01

55

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor; Implantacao de um sistema eletronico para aquisicao de imagens neutrongraficas em tempo real no reator Argonauta do IEN/CNEN  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-15

56

Gravity Gradiometer Survey and Real Time Techniques for ...  

Science.gov (United States)

... 4 II. INERTIAL NAVIGATION ERROR EQUATIONS ..... 5 ... 4- Page 20. Chapter II INERTIAL NAVIGATION ERROR EQUATIONS ...

1981-12-01

57

AeroSpace Information for a Changing World - NASA Technical ...  

Science.gov (United States)

Mar 1, 2011 ... Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary ...

58
59

What will keep the lights on in Ontario: Responses to a policy short-circuit  

Energy Technology Data Exchange (ETDEWEB)

Ontario's electricity industry restructuring program is reviewed, with a view to identify the reasons behind the failure of deregulation which was expected to create competition, to stabilize, or even reduce, prices to consumers, and attract serious private sector investment for the construction of new generating capacity. The report painstakingly reviews the series of events which resulted in a steep rise in electricity rates during the summer of 2002, immediately after deregulation came into effect, which led to freezing retail electricity rates and related charges by the then Conservative provincial government, and the reversal of that decision by the newly-elected Liberal government in the fall of 2003, and plans to bring back retail hydro rates that reflect the cost of production. The authors provide a discussion of policy options and a series of recommendations that are expected to create incentives to reduce and shift demand, encourage the use of ...

2003-12-01

60

Histopathological and immunohistochemical findings of 20 autopsy cases with 2009 H1N1 virus infection.  

Science.gov (United States)

Twenty autopsy cases with 2009 pandemic influenza A (2009 H1N1) virus infection, performed between August 2009 and February 2010, were histopathologically analyzed. Hematoxylin-eosin staining, immunohistochemistry for type A influenza nucleoprotein antigen, and real-time reverse transcription-PCR assay for viral RNA were performed on formalin-fixed and paraffin-embedded specimens. In addition, the D222G amino acid substitution in influenza virus hemagglutinin, which binds to specific cell receptors, was analyzed in formalin-fixed and paraffin-embedded trachea and lung sections by direct sequencing of PCR-amplified products. There were several histopathological patterns in the lung according to the most remarkable findings in each case: acute diffuse alveolar damage (DAD) with a hyaline membrane (four cases), organized DAD (one case), acute massive intra-alveolar edema with variable degrees of hemorrhage (three cases), neutrophilic ...

2011-08-26

61

Fundamental studies of coal liquefaction  

Energy Technology Data Exchange (ETDEWEB)

The authors have examined the pyrolysis of Argonne samples of Wyodak and Illinois No. 6 coal in argon, undecane, Tetralin, and water. The effects of the pyrolysis on individual particles of coal were monitored visually in a cell with diamond windows capable of operation to temperature and pressures in excess of 500{degrees}C and 3000 psi. The changes in the particles from ambient to 460{degrees}C were recorded in real time on video tape, and images were then taken from the tape record and analyzed. The study showed that in argon both coals developed tars at 350{degrees}-370{degrees}C. The tars then quickly evaporated, leaving core particles remarkably similar in size and shape to the initial particles. These observations suggest that coal does not melt nor become fully liquid when heated. Nor does the softened coal undergo crosslinking to generate coke. Rather the simple loss of volatiles leaves behind the core residue as coke. Contrary to the ...

1995-01-01

62

Study on reactivity measurement by the Feynman-#alpha# method  

International Nuclear Information System (INIS)

The Feynman-#alpha# method was applied to measurement of reactivity and the ability of this method for a real-time reactivity monitoring system was assessed. In the experiment, all measured data by BF_3 detectors were stored in a multi-channel scaler controlled by a personal computer, and they were analyzed to obtain prompt neutron decay constant (#alpha#) and reactivity with consideration of dead time of detector. It was found that #alpha# could be obtained almost in a real-time even for both positive and negative reactivities by the present experimental technique. (author).

1996-09-01

63

Real time operating system for a nuclear power plant computer  

International Nuclear Information System (INIS)

A quadruply redundant synchronous fault tolerant processor (FTP) is now under fabrication at the C.S. Draper Laboratory to be used initially as a trip monitor for the Experimental Breeder Reactor EBR-II operated by the Argonne National Laboratory in Idaho Falls, Idaho. The real time operating system for this processor is described.

1986-09-01

64

Real time control of micro-machine system using micro-computer based fuzzy logic power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A micro-computer based fuzzy logic power system stabilizer is applied to a micro-machine system to investigate its efficiency in real time control. The stabilizing signal is determined by using measured speed or real power signals at every sampling time to damp the system oscillations. The results show the proposed stabilizer improves the system damping effectively subject to various types of disturbances.

1994-12-01

65

Real time closed orbit correction system  

Energy Technology Data Exchange (ETDEWEB)

We describe a global closed orbit feedback experiment, based upon a real time harmonic analysis of both the orbit movement and the correction magnetic fields. The feedback forces the coefficients of a few harmonics near the betatron tune to vanish, and significantly improves the global orbit stability. We present the results of the experiment in the UV ring using 4 detectors and 4 trims, in which maximum observed displacement was reduced by a factor of between 3 and 4. 4 refs., 3 figs.

1989-01-01

66

Portable real time neutron spectrometry II  

International Nuclear Information System (INIS)

We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.

2000-01-19

67

Portable real time neutron spectrometry  

International Nuclear Information System (INIS)

We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.

1999-01-22

68

Multiway real-time PCR gene expression profiling in yeast Saccharomyces cerevisiae reveals altered transcriptional response of ADH-genes to glucose stimuli  

UK PubMed Central (United Kingdom)

BackgroundThe large sensitivity, high reproducibility and essentially unlimited dynamic range of real-time PCR to measure gene expression in complex samples provides the opportunity...Full Text Available

69

Amp-PCR: Combining a Random Unbiased Phi29-Amplification with a Specific Real-Time PCR, Performed in One Tube to Increase PCR Sensitivity  

UK PubMed Central (United Kingdom)

In clinical situations where a diagnostic real-time PCR assay is not sensitive enough, leading to low or falsely negative results, or where detection earlier in a disease progression would benefit the...Full Text Available

70

A real time neutron diffraction study on the reaction of AsF_5 with deuterated polyparaphenylene  

International Nuclear Information System (INIS)

The doping of deuterated polyparaphenylene [C_6D_4]sub(n) with AsF_5 has been investigated by real time neutron diffractometry at 100, 400 and 820 mbar AsF_5 pressure. The reaction appears to be diffusion controlled. Evidence for one doped phase with partial crystalline order was obtained. Structural considerations suggest two polymer chains plus one dopant ''string'' as the repetitive unit. (Auth.).

1982-01-01

71

Real-time neutron radiography at the Iea-R1 m nuclear research reactor  

International Nuclear Information System (INIS)

A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was determined and the average ...

2003-06-01

73

Reverse time migration: A seismic processing application on the connection machine  

Science.gov (United States)

The implementation of a reverse time migration algorithm on the Connection Machine, a massively

1987-01-01

74

The application of the neutron time-of-flight technique for real-time diffraction studies  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10{sup 7} neutrons cm{sup -2}s{sup -1} and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t{sub s} of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

75

The application of the neutron time-of-flight technique for real-time diffraction studies  

International Nuclear Information System (INIS)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10"7 neutrons cm"-"2s"-"1 and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t_s of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

76

The Benchmark Test Results of QNX RTOS  

International Nuclear Information System (INIS)

A Real-Time Operating System(RTOS) is an Operating System(OS) intended for real-time applications. Benchmarking is a point of reference by which something can be measured. The QNX is a Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available Personal Computer(PC) for applications such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS). The ELMSYS PC Hardware is being qualified by KTL(Korea Testing Lab.) for use as a Cabinet Operator Module(COM). The QNX RTOS is being dedicated by Korea Atomic Energy Research Institute (KAERI). This paper describes the outline and benchmarking test results on Context Switching, Message Passing, Synchronization and Deadline Violation of QNX RTOS under the ELMSYS PC platform

2010-10-01

77

Real-time neutron radiography for visualisation of interfacial geometry and phase distribution in two-phase flow  

International Nuclear Information System (INIS)

Results of ongoing research project at the McMaster Nuclear Reactor Facility on real-time neutron radiography for the visualization of interfacial geometry, movements and phase distributions in gas-liquid and gas-liquid-metal multi-phase flows are presented. Experiments were conducted with bubble column tubes with boiling liquid nitrogen, air-water and air-mercury mixtures. Discussions are also focused on air-water flowing within a tube containing a CANDU type 37 rod fuel bundle assembly positioned both horizontally and vertically. Computer processing using a digital image format to enhance the real-time images was used. Imaging techniques include frame averaging, background substraction, edge enhancement (spatial filtering), contrast enhancement and video densitometry. (orig.).

1989-10-01

78

Real-time coordination of secondary voltage control and power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

This paper is devoted to the coordination of secondary voltage control and adaptive parameters resetting of the power system stabilizer, in order to increase stability, margins in real time operation. Secondary voltage control and the power system stabilizer are two control loops, which affect the same system parameter on different bases - that parameter is the voltage set-point of the automatic voltage regulator. It was found that their effects were complementary. In that way, through the proper coordination of actions of these two control loops open up a wide range of possibilities for ensuring the stability of bulk power systems in real time. For the establishment of this coordination, an on-line sequential algorithm is proposed which is based on adaptive resetting of the voltage set-point of the automatic voltage regulator and the PSS parameters. The efficiency of the proposed algorithm is confined ...

2002-06-01

79

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

80

Real time automatic discriminating of ultrasonic flaws  

International Nuclear Information System (INIS)

This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft ...

2009-07-20

81

Observations of unsaturated water flow using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography was demonstrated to be a viable and useful tool in studying water flow in unsaturated media. The experiment was designed to test the method for following water flow. The wetting front advance, water-flow patterns, and neutron attenuation density were observed in a 7.7-cm diameter sand column. The advance was fit with a simple i = A t/sup B/ equation yielding an excellent correlation. Theoretical calculations presented estimate the minimum and maximum detectable water content in various sizes of columns. The ability of real-time neutron radiography to allow both qualitative and quantitative spatial and time measurements to be made in an nonintrusive manner was demonstrated.

1987-08-01

82

Observations of unsaturated water flow using real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography was demonstrated to be a viable and useful tool in studying water flow in unsaturated media. The experiment was designed to test the method for following water flow. The wetting front advance, water-flow patterns, and neutron attenuation density were observed in a 7.7-cm diameter sand column. The advance was fit with a simple i = A t/sup B/ equation yielding an excellent correlation. Theoretical calculations presented estimate the minimum and maximum detectable water content in various sizes of columns. The ability of real-time neutron radiography to allow both qualitative and quantitative spatial and time measurements to be made in an nonintrusive manner was demonstrated.

1987-01-01

83

Nondestructive characterization of low-level transuranic waste  

Energy Technology Data Exchange (ETDEWEB)

The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production waste characterization ...

1981-10-01

84

Liquid metal flow measurement by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd{sub 3}) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).

1996-07-21

85

Liquid metal flow measurement by neutron radiography  

International Nuclear Information System (INIS)

Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd_3) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).

1996-07-01

86

Electronic imaging system for neutron radiography at a low power research reactor  

Energy Technology Data Exchange (ETDEWEB)

This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.

2010-08-15

87

Electronic imaging system for neutron radiography at a low power research reactor  

International Nuclear Information System (INIS)

This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.

2010-08-01

88

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration of neutron statistics ...

1994-08-01

89

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

International Nuclear Information System (INIS)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration of neutron statistics ...

1994-01-01

90

Development of electronic imaging system for real time neutron radiography at TRIGA MK-II research reactor of AERE, Savar, Dhaka and utilization for research and industrial applications  

International Nuclear Information System (INIS)

The neutron radiography facility was installed at the tangential beam port of the 3 MW TRIGA MARK-II research reactor. In the facility only direct film neutron radiography method is being used. The project involves development of electronic imaging system for real time neutron radiography in the existing facility with the aim of utilizing it for research and industrial applications. In establishing the electronic imaging system for real time neutron radiography the improvements of existing facility were almost done during this period. In parallel, the former facility was used for the research: (a) A study of wood and wood plastic composites with and without additive by using film neutron radiography and (b) A study of jute reinforced polymer composites by using film neutron radiography technique. (author)

2008-09-01

91

Verification of MLC based real-time tumor tracking using an electronic portal imaging device  

UK PubMed Central (United Kingdom)

Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available

2010-06-01

92

Ultrasonic Acoustic Emissions from the Sapwood of Thuja occidentalis Measured inside a Pressure Bomb 1  

UK PubMed Central (United Kingdom)

An improved method of counting acoustic emission (AE) events from water-stressed stems of cedar (Thuja occidentalis L.) is presented. Amplified AEs are analyzed on a real time basis...Full Text Available

1984-04-01

93

The sensitivity of real-time PCR amplification targeting invasive Salmonella serovars in biological specimens  

UK PubMed Central (United Kingdom)

BackgroundPCR amplification for the detection of pathogens in biological material is generally considered a rapid and informative diagnostic technique. Invasive Salmonella...Full Text Available

94

Surface EMG pattern recognition for real-time control of a wrist exoskeleton  

UK PubMed Central (United Kingdom)

BackgroundSurface electromyography (sEMG) signals have been used in numerous studies for the classification of hand gestures and movements and successfully implemented in the position...Full Text Available

95

Real-time neutron radiography system performance - Measurements and methods  

Energy Technology Data Exchange (ETDEWEB)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the ...

1988-09-01

96

Real-time neutron radiography system performance - Measurements and methods  

International Nuclear Information System (INIS)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time system, including both the neutron beam and the ...

1988-01-01

97

Real-time monitoring of circadian clock oscillations in primary cultures of mammalian cells using Tol2 transposon-mediated gene transfer strategy  

UK PubMed Central (United Kingdom)

BackgroundThe circadian rhythm in mammals is orchestrated by a central pacemaker in the brain, but most peripheral tissues contain their own intrinsic circadian oscillators. The...Full Text Available

98

Real-Time Assessment of Cardiac Perfusion, Coronary Angiography, and Acute Intravascular Thrombi Using Dual-Channel Near-Infrared Fluorescence Imaging  

UK PubMed Central (United Kingdom)

ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available

2009-07-01

99

Real-Time Aerodynamic ... - NASA Technical Report Server (NTRS)  

Science.gov (United States)

... least squares cost function is computed from1. (. ) ( ). 1. X X. X z. . . ?. Re. Re. -. . . = . . . . (25). The estimated parameter covariance matrix is1 ...

100

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

101

Propagation of human embryonic and induced pluripotent stem cells in an indirect co-culture system  

UK PubMed Central (United Kingdom)

We have developed and validated a microporous poly(ethylene terephthalate) membrane-based indirect co-culture system for human pluripotent stem cell (hPSC) propagation, which allows real-time...Full Text Available

2010-03-05

102

Optimization of neutron-to-light converter screens for use in real-time neutron radiography  

International Nuclear Information System (INIS)

In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in the development of real-time neutron radiography systems and neutron-to-light converter screens optimized for real-time application. Two screens currently available at MURR are: (1) a 0.041-cm-thick Gd_2O_2S screen manufactured by 3M Company and (2) a "6KiF-ZnS(Ag) screen (NE 426) manufactured by Nuclear Enterprises. These screens are presently used in conventional film neutron radiography and represent two of the commercially available screens that have demonstrated the greatest resolution and sensitivity. Unfortunately, these screens have severe limitations when used for real-time neutron radiography. In order to isolate and minimize the factors contributing to these limitations, several neutron absorbers and phosphorus were studied at MURR. The screen thickness and the ...

1982-04-01

103

On-line real-time measurements of decontamination factor for a low-level waste incinerator  

Energy Technology Data Exchange (ETDEWEB)

The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.

1983-01-01

104

On-line real-time measurements of decontamination factor for a low-level waste incinerator  

International Nuclear Information System (INIS)

The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.

105

Monitoring of NK-Cell Immunotherapy using non-invasive Imaging Modalities  

UK PubMed Central (United Kingdom)

Cancer immunotherapies can be guided by cellular imaging techniques, which can identify the presence or absence of immune-cell accumulation in the tumor tissue in-vivo and in real time. This...Full Text Available

2010-08-01

106

Managing high-bandwidth real-time data storage  

Energy Technology Data Exchange (ETDEWEB)

There exist certain systems which generate real-time data at high bandwidth, but do not necessarily require the long-term retention of that data in normal conditions. In some cases, the data may not actually be useful, and in others, there may be too much data to permanently retain in long-term storage whether it is useful or not. However, certain portions of the data may be identified as being vitally important from time to time, and must therefore be retained for further analysis or permanent storage without interrupting the ongoing collection of new data. We have developed a system, Mahanaxar, intended to address this problem. It provides quality of service guarantees for incoming real-time data streams and simultaneous access to already-recorded data on a best-effort basis utilizing any spare bandwidth. It has built in mechanisms for reliability and indexing, can scale upwards to meet increasing bandwidth requirements, and handles both ...

2009-01-01

107

Management and optimization of the CPCU network working  

Energy Technology Data Exchange (ETDEWEB)

The CPCU steam distribution network is supplemented by a return network for the condensation water. The data system installed in 1988 provides, for the real time, management of the function of the two networks and a reduction in production costs. For the steam, data required in the network, the boiler houses and from external sources are processed by local network of five microprocessors and permit: - with time delay: technical and economic production optimizing calculations, or forecasts, for the following day, of the total required output and the procedure necessary for supplying this at the lowest cost; - in real time: on the basis of the forecasts for the previous day, creating the production instructions for the boiler houses and the instructions for the network remote control elements; - in case of an unexpected occurrence: immediate creation of new operating forecasts for the boiler houses for ...

1991-10-01

108

MTF analysis of the MURR real-time neutron radiography facility  

International Nuclear Information System (INIS)

In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used was to image a knife-edge, differentiate ...

1982-04-01

109

Identification of CTX-M-Type Extended-Spectrum-?-Lactamase Genes Using Real-Time PCR and Pyrosequencing?  

UK PubMed Central (United Kingdom)

CTX-M extended-spectrum β-lactamases (ESBLs) are increasingly prevalent worldwide among Escherichia coli bacteria, mostly in community-acquired urinary tract infections. Finding...Full Text Available

2007-01-01

110

Human Lymphatic Architecture and Dynamic Transport Imaged Using Near-infrared Fluorescence12  

UK PubMed Central (United Kingdom)

BACKGROUND: Although the importance of lymphatic function is well recognized, the lack of real-time imaging modalities limits our understanding of its role in many diseases. In a phase...Full Text Available

111

High-Sensitivity Analysis of Naturally Occurring Sugar Chains, Using a Novel Fluorescent Linker Molecule  

UK PubMed Central (United Kingdom)

To analyse the binding of sugar chains to proteins, viruses and cells, the surface plasmon resonance (SPR) technique is very convenient and effective because it is a real-time, non-destructive detection...Full Text Available

2009-07-01

112

Evolutionary Trajectories of Beta-Lactamase CTX-M-1 Cluster Enzymes: Predicting Antibiotic Resistance  

UK PubMed Central (United Kingdom)

Extended-spectrum beta-lactamases (ESBL) constitute a key antibiotic-resistance mechanism affecting Gram-negative bacteria, and also an excellent model for studying evolution in real time. A shift in...Full Text Available

2010-01-01

113

EcoEarth.Info Environment Links: Water/Rivers  

Wastenet

... 03, 2001 | Rate It Lake Superior Streams http://www.lakesuperiorstreams.org/ (1 vote) interactively examine real-time water quality data from 5 ...north shore Lake Superior trout streams and learn about other streams in the region, how they \\

115

Beyond Ada - generating Ada code from equational specifications  

Energy Technology Data Exchange (ETDEWEB)

Real-time mission-oriented embedded systems are much more difficult to design than ordinary software systems. They require highly reliable and efficient implementations to satisfy mission and time constraints imposed by the applications. The Ada language was designed to facilitate real-time-system software development. However, for many programmers the size and complexity of Ada itself are of concern. In the assertive programming paradigm, computations are specified as sets of assertions about properties of the solution, and not as a sequence of procedural steps. Solving procedures are automatically generated from the assertive description. Real-time programming for mission-oriented systems is supported by equational languages in which assertions are expressed as algebraic equations. Programs written in equational languages are concise, free from implementation details, and easily amenable to verification and parallel ...

1987-01-01

116

Assessment and Refinement of Real-Time Travel Time Algorithms for Use in Practice, Phase II.  

Science.gov (United States)

The Federal Highway Administration (FHWA) has put a high priority on the use of existing dynamic message signs (DMS) to provide travel time estimates to the public. The Oregon Department of Transportation (ODOT) has three DMS in the Portland metropolitan ...

2011-01-01

117

Analysis of Quantitative Interactions between Two Species of Arbuscular Mycorrhizal Fungi, Glomus mosseae and G. intraradices, by Real-Time PCR  

UK PubMed Central (United Kingdom)

Arbuscular mycorrhizal fungi (AMF) are obligate biotrophs, known to play an important role in ecological processes. Conventional light microscopy is the most common method used to detect their presence...Full Text Available

2006-06-01

118

An Integrated System for Total Cardiac Monitoring of the Critically Ill  

UK PubMed Central (United Kingdom)

An integrated system of micro-and mini-computers is described to acquire, analyze, store and report data on the total activity of the heart of a critically ill patient. Real-time beat and rhythm diagnoses...Full Text Available

1977-10-05

119

ADVANCED MICROELECTRONICS TECHNOLOGIES FOR - NASA  

Science.gov (United States)

... and technology-. The United States National Technology Roadmap for Semiconductors [ 11 still ... Moreover, higher volumes of production, better manufacturing capabilities and ... energy-efficient, reliable, high-performance, embedded (real-time), highly miniaturized, .... Optical Computing, Storage, and Communications. ...

120

Use of real-time neutron radiography at the Penn State Breazeale Nuclear Reactor for solving industrial problems  

Energy Technology Data Exchange (ETDEWEB)

The study of the dynamics of lubricants and mechanical components encased in metal enclosures is important to many industries. Of particular importance is the flow characteristics of oils or similar lubricants within the metal enclosure during operation of the device. The purpose of this summary is to report on the design and successful application of a real-time neutron radiography system to study the lubrication and design of the piston and seal of a gas spring. In addition, the application of this technique to a wider range of similar problems using the pulse capability of the TRIGA reactor is described.

1986-01-01

121

Use of real-time neutron radiography at the Penn State Breazeale Nuclear Reactor for solving industrial problems  

International Nuclear Information System (INIS)

The study of the dynamics of lubricants and mechanical components encased in metal enclosures is important to many industries. Of particular importance is the flow characteristics of oils or similar lubricants within the metal enclosure during operation of the device. The purpose of this summary is to report on the design and successful application of a real-time neutron radiography system to study the lubrication and design of the piston and seal of a gas spring. In addition, the application of this technique to a wider range of similar problems using the pulse capability of the TRIGA reactor is described.

1986-11-16

122

SNRS component positioning systems  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses the stationary neutron radiography system (SNRS) with respect to the component positioning systems (CPSs) and the rationale behind their design. As design work is on-going at Science Applications International Corporation, this report gives a current update of progress. The SNRS has four separate radiography bays, Bays 1 through 4. The first three bays have automated positioning systems for real-time and near real-time neutron radiography of aircraft components. Bay 4 has been designed to accommodate components from the solid rocket booster, but will be used first for film radiography of pyrotechnic components.

1987-01-01

123

SNRS (stationary neutron radiography system) component positioning systems  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses the stationary neutron radiography system (SNRS) with respect to the component positioning systems (CPSs) and the rationale behind their design. As design work is on-going at science Applications International Corporation, this report gives a current update of progress. The SNRS has four separate radiography bays, Bays 1 through 4. The first three bays have automated positioning systems for real-time and near real-time neutron radiography of aircraft components. Bay 4 has been designed to accommodate components from the solid rocket booster, but will be used first for film radiography of pyrotechnic components.

1987-01-01

124

Real-time neutron radiography at McMaster  

International Nuclear Information System (INIS)

The McMaster Neutron Radiography Facility (MNRF) is fortunate to own the only Real-Time Neutron Radiography system in Canada. Current research at the MNRF involves the visualization of gas-liquid and gas-solid two-phase flow in complex channels, such as nuclear fuel channels, using light water, heavy water, freon-134A, slurries, and other fluids. Other research at the MNRF has examined single-phase flow, material purity, film deposition, turbine blades, and automotive parts.

1995-01-01

125

Real-time neutron diffraction study of phase transitions in the Ti-D system after high pressure treatment  

International Nuclear Information System (INIS)

Phase transformations in TiD_#approx#_0_._7_5 subjected to high-pressure treatment were investigated by simultaneous real-time measurements of neutron diffraction and small-angle neutron scattering. The neutron spectra were taken on heating the samples in temperature ranges 100 to 300 K and 300 to 870 K. A sequence of structural transitions was observed, which involves 7 different phases and intermediate states with hcp, fcc, fco or bcc metal sublattices and hydrogen atoms. 30 refs., 9 figs., 1 tab.

1992-09-01

126

Real time neutron transmission investigation of the austenite-bainite transformation in grey iron  

Energy Technology Data Exchange (ETDEWEB)

The first successful application of a new method to investigate phase transformations in real time, like the decomposition of austenite into bainite in grey iron, is described. During the ongoing transformation, transmission spectra of thermal neutrons, which contain Bragg edges corresponding to the crystal structure of the transforming phases, are recorded. By evaluating the height of these Bragg edges, which is a measure of the volume fraction of the phase, at different transformation times, the transformation can be followed in-situ in a time resolved manner. The method is compared to other previously used methods (micrographs, dilatometry, diffraction techniques); also a summary and an outlook are given. ((orig.))

1994-06-01

127

Real time neutron transmission investigation of the austenite-bainite transformation in grey iron  

International Nuclear Information System (INIS)

The first successful application of a new method to investigate phase transformations in real time, like the decomposition of austenite into bainite in grey iron, is described. During the ongoing transformation, transmission spectra of thermal neutrons, which contain Bragg edges corresponding to the crystal structure of the transforming phases, are recorded. By evaluating the height of these Bragg edges, which is a measure of the volume fraction of the phase, at different transformation times, the transformation can be followed in-situ in a time resolved manner. The method is compared to other previously used methods (micrographs, dilatometry, diffraction techniques); also a summary and an outlook are given. ((orig.)).

1994-01-01

128

Real time neutron dosemeter response calculations  

International Nuclear Information System (INIS)

The response of a real time neutron dosemeter using a thin LiF target sandwiched between tow parallel surface barrier semiconductor detectors is studied for different neutron distributions and different angles of incidence. Calculations of the response function defined for a simultaneous detection by the two detectors of the particles emitted when the reaction "6Li(n,t)#alpha# occurs in the target are fulfilled by geometrical considerations of the reaction kinematics and the differential cross section variations. Finally, the efficiency of the studied detection systems is analyzed for dosimetric uses. (author).

1996-04-01

129

Real time neutron diffraction study on the reaction of AsF/sub 5/ with deuterated polyparaphenylene  

Energy Technology Data Exchange (ETDEWEB)

The doping of deuterated polyparaphenylene (C/sub 6/D/sub 4/)sub(n) with AsF/sub 5/ has been investigated by real time neutron diffractometry at 100, 400 and 820 mbar AsF/sub 5/ pressure. The reaction appears to be diffusion controlled. Evidence for one doped phase with partial crystalline order was obtained. Structural considerations suggest two polymer chains plus one dopant ''string'' as the repetitive unit.

1982-07-01

130

Quantitative variations in the vaginal bacterial population associated with asymptomatic infections: a real-time polymerase chain reaction study.  

Science.gov (United States)

The real-time polymerase chain reaction (PCR) quantification of several vaginal bacterial groups in healthy women and patients developing asymptomatic bacterial vaginosis (BV) and candidiasis (CA) was performed. Statistical analysis revealed that the BV condition is characterised by a great variability among subjects and that it is associated with a significant increase of Prevotella, Atopobium, Veillonella and Gardnerella vaginalis, and a drop in Lactobacillus. On the contrary, the vaginal microflora of healthy women and patients developing CA was found to be homogeneous and stable over time. PMID:18762999

2008-09-02

131

Quantitative variations in the vaginal bacterial population associated with asymptomatic infections: a real-time polymerase chain reaction study  

British Library Electronic Table of Contents (United Kingdom)

The real-time polymerase chain reaction (PCR) quantification of several vaginal bacterial groups in healthy women and patients developing asymptomatic bacterial vaginosis (BV) and candidiasis (CA) was performed. Statistical analysis revealed that the BV condition is characterised by a great variability among subjects and that it is associated with a significant increase of Prevotella, Atopobium, Veillonella and Gardnerella vaginalis, and a drop in Lactobacillus. On the contrary, the vaginal microflora of healthy women and patients developing CA was found to be homogeneous and stable over time.

2009-01-01

132

Making sense of leak detection  

Energy Technology Data Exchange (ETDEWEB)

It is estimated that more than 180.000 kilometres of onshore pipelines will be installed between now and 2012. According to the US Federal Office of Pipeline Safety report (1968-97), the average pipeline suffers one leak per year every 400 miles. This equates to a total of 180 expected leaks per year for a new pipeline alone. Sensornet's continuous real-time Digital Leak Detection monitoring solution has the reach, precision and the speed to provide complete, continuous real-time knowledge (author)

2008-07-01

133

Endomicroscopy imaging of epithelial structures using tissue autofluorescence  

Science.gov (United States)

We explore autofluorescence endomicroscopy as a potential tool for real-time visualization of epithelial tissue microstructure and organization in a clinical setting. The design parameters are explored using two experimental systems--an Olympus Medical Systems Corp. stand-alone clinical prototype probe, and a custom built bench-top rigid fiber conduit prototype. Both systems entail ultraviolet excitation at 266 nm and/or 325 nm using compact laser sources. Preliminary results using ex vivo animal and human tissue specimens suggest that this technology can be translated toward in vivo application to address the need for real-time histology.

2011-04-01

134

Directional wind-measurement derived from elastic backscatter lidar data in real-time  

Energy Technology Data Exchange (ETDEWEB)

The development of a capability to infer wind velocities simultaneously at a number of ranges along one direction in real time is described. The elastic backscatter lidar data used was obtained using the XM94 lidar, developed by Los Alamos National Laboratory for the US Army Chemical and Biological Detection Command. In some respects this problem is simpler than measuring wind velocities on meso-meteorological scales. Other requirements, particularly high temporal fidelity, have driven the development of faster software algorithms and suggested opportunities for the evolution of the hardware.

1996-04-01

135

Conception, realization and test of an electronic Si-LiF-Si sensor for neutron spectrometry and dosimetry  

International Nuclear Information System (INIS)

The aim of this thesis is the study of new systems devoted to the real time neutron spectrometry and dosimetry. The microelectronics technologies have been used to research a micro system integrating sensor and data processing in real time. The multi range sensor is based on many pair of semiconductor diodes placed face to face and covered by lithium fluoride. The sensor has been designed and its behavior has been simulated. Its operating in reference neutrons beams has been analyzed. (A.L.B.)

1998-01-01

136

Application of neutron radiography to a diagnosis of refrigerator  

International Nuclear Information System (INIS)

A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).

1996-07-01

137

#mu#C/OS-II the real-time kennel and its new progress  

International Nuclear Information System (INIS)

A lot of effort has been made to spread the application of RTOS in embedded system development in China. RTOS, #mu#C/OS and #mu#C/OS-II, with its opened source code, is well known in embedded systems. Learning RTOS, Using RTOS, becomes more and more popular. The Book of 'Micro C/OS-II The Real-Time Kennel Second Edition' was published in 2002. Here some new progress of the RTOS, especially the safety certifications, the reliability of software is introduced. (authors)

2003-09-08

139

Automated real-time testing (ARTT) for embedded control systems (ECS).  

Energy Technology Data Exchange (ETDEWEB)

Many of today's automated real-time testing systems for embedded systems were developed using expensive custom hardware and software. In this article they describe how to use commercially available off-the-shelf hardware and software to design and develop an automated real-time test systems for Embedded Programmable Logic Controller (PLC) Based Control Systems. The system development began with the implementation of the VALI/TEST Pro testing methodology as a means for structuring the testing. Using this methodology, they were able to decompose system requirement documents for a Personnel Safety System (PSS) into its high, intermediate and detail level requirements. next, the validation procedures for the PSS system were decomposed into testing units called builds, test runs and test cases. To measure the PSS system's test coverage three levels of system requirements were mapped to their respective unit level of test using a ...

2001-08-09

140

Review of JT-60U experimental results from February to October, 1999  

International Nuclear Information System (INIS)

In 1999, the plasma parameters of reversed shear (RS) plasmas had been extended in 1) DT-equivalent fusion power gain Q_D_T"e"q - 0.5 (n_D(0)#tau#_ET_i(0) - 4x10"2"0 m"-"3#centre dot#keV#centre dot#s) for 0.8 s and 2) full non-inductive current drive with 80% of the bootstrap current fraction. Physics of the internal transport barriers (ITBs) in RS plasmas, including the energy transport and the formation of ITB, were extensively studied. A nearly full current drive (92% non-inductively) was obtained with negative ion based neutral beam (NNB) injection (360 keV, 3.4 MW) in a high #beta#_p H-mode plasma (I_p=1.5 MA, B_T=3.7 T, q_9_5=4.2) with high plasma performance (#beta#_N=2.4 and H_8_9=2.56). Rise in the central electron temperature (T_e - 9 keV) resulted in the current drive efficiency #eta#_C_D of NNB reached 1.3x10"1"9 A/W/m"2, the highest for the neutral beam current drive. As for the H-mode plasmas, decrease in the pedestal ion temperature due to strong gas ...

1994-06-01

141

Ultra high-speed (508 MHz) beam position digital feedback system  

Energy Technology Data Exchange (ETDEWEB)

The B-Factory which is constructed by National Laboratory for High Energy Physics is the device for elucidating the breakdown of symmetry of matter and antimatter by studying the behavior of B mesons which are generated in large quantity when the electrons and the positrons which are accelerated to light velocity level are collided. In order to maintain electron beam-positron beam bunch circling the ring at light velocity stably, the instability of the coupled bunch must be overcome. For this purpose, the ultrahigh speed beam position digital feedback control system was developed. This system is composed of the high speed input-output substrate using GaAs LSI, the feedback computation substrate using complementary metal oxide semiconductor and the memory mounted on it, and the real time operation device. The development of both substrates and their functions are explained. The real time data collection ...

1997-02-01

142

Real-time 3-D SAFT-UT system evaluation and validation  

International Nuclear Information System (INIS)

SAFT-UT technology is shown to provide significant enhancements to the inspection of materials used in US nuclear power plants. This report provides guidelines for the implementation of SAFT-UT technology and shows the results from its application. An overview of the development of SAFT-UT is provided so that the reader may become familiar with the technology. Then the basic fundamentals are presented with an extensive list of references. A comprehensive operating procedure, which is used in conjunction with the SAFT-UT field system developed by Pacific Northwest Laboratory (PNL), provides the recipe for both SAFT data acquisition and analysis. The specification for the hardware implementation is provided for the SAFT-UT system along with a description of the subsequent developments and improvements. One development of technical interest is the SAFT real time processor. Performance of the real-time processor is impressive ...

1993-05-17

143

In situ, real-time RBS measurement of solid state reaction in thin films  

International Nuclear Information System (INIS)

The applicability of in situ, real-time RBS is demonstrated by characterizing the growth of thin Pd_2Si films on Si left angle 111 right angle substrates using isothermal as well as non-isothermal annealing. In contrast to the currently fashionable in situ ramped resistance technique, it is possible to extract the activation energy from a single run with a constant heating rate. The results, which are in excellent agreement with the literature, will be compared for isothermal annealing, fitting an appropriate model for the growth process to data from a single run and a Kissinger-like analysis with different ramp rates. In situ, real-time RBS was also used to study marker motion during CrSi_2 formation in the Si left angle 100 right angle /Pd_2Si/Cr system. It is possible to distinguish between the following mechanisms: (1) CrSi_2 formation via dissociation of the Pd_2Si at the Pd_2Si/Cr interface and subsequent reaction of Pd to form Pd_2Si at ...

1998-04-01

144

Development of real time personal neutron dosimeter with two silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

The personal neutron dosimetry becomes more important with the increasing use of nuclear and accelerator facilities. The solid state track detector, film badge and thermo-luminescent dosimeter have widely been used as passive-type personal neutron dosimeters, but the real-time neutron dosimeter is strongly needed. A real time personal dosimeter which could give neutron dose equivalent over wide energy range from thermal to 10 odd MeV by using two neutron sensors has been developed by our group. For practical commercial product, some changes from these prototype sensors have recently been done by Fuji Electric Co. Ltd. The purpose of this work is the final performance test of the dosimeter just before sale. We checked again about the sensitivity in the monoenergetic neutron field from 8 keV to 15 MeV and in the neutron fields around a few accelerator facilities. (author)

1997-07-01

145

A study on the radiation and environmental safety -Development of a real-time radiological dose assessment system-  

Energy Technology Data Exchange (ETDEWEB)

The real-time dose assessment system under development has been updated and the technology for tracer experiment has been established. The calculation of external gamma dose is the most difficult and time-consuming part of the dose calculations. The characteristics of external gamma exposure have been investigated and the method for reducing the calculation time has been devised. The internal exposure via the ingestion of the contaminated foodstuffs is one of the important pathways to the total radiological exposure. In the emergency, it is necessary to take an action such like food ban to protect the internal exposure. An algorithm for the interface between the real-time system and the food chain model has been provided. The second field tracer experiment over flat terrain has been carried out on a plain in Iksan city in Junrabook-Do. Sequential tracer sampler which can be sampled the tracer gas over arbitrary 12 time interval has been ...

1995-07-01

146

The new JET phased ICRH array: first experiments and modelling  

Energy Technology Data Exchange (ETDEWEB)

New ICRH antennas on JET were designed to couple to the new JET divertor plasma configurations and to improve the Fast Wave Current Drive (FWCD) capabilities. The A2 antenna consists of 4 straps whose currents can be phased at arbitrary angles. The real time automatic tuning acts on frequency, line length (line phase shifters) and stub length. Provision is made for the coupling resistance/plasma position feedback to accommodate the fast changes in antenna loading. The first coupling, tuning and heating results are reported in 0{pi}0{pi}, 0000 and 00{pi}{pi} phasing. A new antenna model is described, which was developed to simulate the measured antenna loading in terms of plasma parameters and to provide a starting point for the real time automatic tuning. 5 refs., 4 figs.

1994-07-01

147

STAR: a local network system for real-time management of imagery data  

Energy Technology Data Exchange (ETDEWEB)

Overall architecture of a local computer network, STAR, is described. The objective is to accomplish a cost-effective system which provides multiple users a real-time service of manipulating very large volume imagery information and data. STAR consists of a reconfigurable communication subnet (starnet), heterogeneous resource units, and distributed-control software entities. Architectural aspects of a fault-tolerant communication subnet, distributed database management, and a distributed scheduling strategy for configuring desirable computation topology are exploited. A model for comparing cost-effectiveness among starnet, crossbar, and multiple buses is included. It is concluded that starnet outperforms the other two when the number of units to be connected is larger than 64. This project serves as a research tool for using current and projected technology to innovate better schemes for parallel image processing. 30 references.

1982-10-01

148

Repetitive model refactoring strategy for the design space exploration of intensive signal processing applications  

British Library Electronic Table of Contents (United Kingdom)

The efficient design of computation intensive multidimensional signal processing applications requires dealing with three kinds of constraints: those implied by the data dependencies, the non-functional requirements (real-time, power consumption) and resources availability of the execution platform. Modeling and Analysis of Real-time and Embedded systems (MARTE) UML profile through its repetitive structure modeling (RSM) package is well suited to model the inherent parallelism within these applications, a compact representation of parallel execution platforms and the distributive mapping of one on another. The execution of such a specification respects the whole set of constraints defined upon, while the quality of the scheduling is directly linked to the quality of the mapping of the mult...

2011-01-01

149

Real-time orbit feedback at the APS.  

Energy Technology Data Exchange (ETDEWEB)

A real-time orbit feedback system has been implemented at the Advanced Photon Source in order to meet the stringent orbit stability requirements. The system reduces global orbit motion below 30Hz by a factor of four to below 5{micro}m rms horizontally and 2{micro}m rms vertically. This paper focuses on dynamic orbit stability and describes the all-digital orbit feedback system that has been implemented at the APS. Implementation of the global orbit feedback system is described and its latest performance is presented. Ultimately, the system will provide local feedback at each x-ray source point using installed photon BPMs to measure x-ray beam position and angle directly. Technical challenges associated with local feedback and with dynamics of the associated corrector magnets are described. The unique diagnostic capabilities provided by the APS system are discussed with reference to their use in identifying sources of the underlying orbit motion.

1998-06-18

150

Real-time neutron radiography applications in dynamic fluid flow studies  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (RTNR) is now proving to be a valuable research tool in the study of hydrogenous fluid flow. One of the most significant advantages of neutron radiography is the ability to image hydrogenous substances (such as lubricants, coolants, and fuels) inside metallic materials such as aluminum and titanium engines. By using RTNR, one can then study dynamic events such as the movement of liquids inside these solids. The Phoenix Memorial Laboratory (PML) at the University of Michigan has recently developed and installed a facility dedicated to RTNR. The work at PML has shown that RTNR of dynamic events can provide information enabling the researcher to follow dynamic events that were previously impossible or impractical. This paper will show the variety of uses of RTNR presently being pursued at PML.

1986-01-01

151

Real-time neutron radiography applications in dynamic fluid flow studies  

International Nuclear Information System (INIS)

Real-time neutron radiography (RTNR) is now proving to be a valuable research tool in the study of hydrogenous fluid flow. One of the most significant advantages of neutron radiography is the ability to image hydrogenous substances (such as lubricants, coolants, and fuels) inside metallic materials such as aluminum and titanium engines. By using RTNR, one can then study dynamic events such as the movement of liquids inside these solids. The Phoenix Memorial Laboratory (PML) at the University of Michigan has recently developed and installed a facility dedicated to RTNR. The work at PML has shown that RTNR of dynamic events can provide information enabling the researcher to follow dynamic events that were previously impossible or impractical. This paper will show the variety of uses of RTNR presently being pursued at PML.

1986-11-16

152

Real-time neutron monitoring method using an imaging plate  

Energy Technology Data Exchange (ETDEWEB)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-07-01

153

Real-time neutron monitoring method using an imaging plate  

International Nuclear Information System (INIS)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-04-19

154

Real-time monitoring of moisture levels in wound dressings in vitro: An experimental study  

British Library Electronic Table of Contents (United Kingdom)

Retaining an appropriate level of moisture at the interface between a healing wound and an applied dressing is considered to be critical for effective wound healing. Failure to control exudate at this interface can result in maceration or drying out of the wound surface. The ability to control moisture balance at the wound interface is therefore a key aspect of wound dressing performance. To date it has not been possible to monitor in any effective manner the distribution of moisture within dressings or how this varies with time.A new measurement system is presented based on sensors placed at the wound/dressing interface which are capable of monitoring moisture levels in real time. The system comprises a model wound bed and sensor array complete with fluid injection path to mimic exudate f...

2007-01-01

155

Real-time imaging for neutron radiography at KURRI  

International Nuclear Information System (INIS)

For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).

1987-07-01

156

Real-time configuration changes of the ATLAS High Level Trigger  

CERN Document Server

The ATLAS High Level Trigger (HLT) is a distributed real-time software system that performs the final online selection of events produced during proton-proton collisions at the Large Hadron Collider (LHC). It is designed as a two-stage trigger and event filter running on a farm of commodity PC hardware. Currently the system consists of about 850 processing nodes and will be extended incrementally following the expected increase in luminosity of the LHC to about 2000 nodes. The event selection within the HLT applications is carried out by specialized reconstruction algorithms. The selection can be controlled via properties that are stored in a central database and are retrieved at the startup of the HLT processes, which then usually run continuously for many hours. To be able to respond to changes in the LHC beam conditions, it is essential that the algorithms can be re-configured without disrupting data taking while ensuring a consistent and reproducible ...

2010-01-01

157

Real time study of the crystallization of aluminium-base icosahedral phases by neutron powder diffraction  

International Nuclear Information System (INIS)

The thermal transformation of Al-base icosahedral phases was studied in-situ by real time neutron powder diffraction. Different compositions have been selected in order to vary the initial phase morphology and change the neutron scattering contrast between species. Alloys with low silicon and large aluminium contents produce first the orthorhombic O-Al_6Mn modification. In alloys with larger silicon content, the #alpha#-AlMnSi cubic phase appears soon after the beginning of the transformation but is still preceeded by O-Al_6Mn. Depending on compositions, the crystallization of the icosahedral phase is controlled either by the diffusion of Al through its interface with the residual fcc aluminium or that of Si within the bulk. The results are discussed in the light of current structural models. (author) 40 refs., 14 figs., 3 tabs.

1987-01-01

158

Real time neutron radiography using a Lixi neutron imaging device  

Energy Technology Data Exchange (ETDEWEB)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged.

1986-01-15

159

Real time neutron radiography using a Lixi neutron imaging device  

International Nuclear Information System (INIS)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged. (orig.).

1986-01-01

160

Quantitation of infectious myonecrosis virus in different tissues of naturally infected Pacific white shrimp, Litopenaeus vannamei, using real-time PCR with SYBR Green chemistry  

British Library Electronic Table of Contents (United Kingdom)

The Pacific white shrimp, Litopenaeus vannamei, is the most important shrimp species in volume in world aquaculture. However, in recent decades, outbreaks of diseases, especially viral diseases, have led to significant economic losses, threatening the sustainability of shrimp farming worldwide. In 2004, Brazilian shrimp farming was seriously affected by a new disease caused by the Infectious myonecrosis virus (IMNV). Thus, disease control based on rapid and sensitive pathogen detection methods has become a priority. In this study, a specific quantitation method for IMNV was developed using real-time PCR with SYBR Green chemistry and viral load of the principal target tissues of chronically infected animals was quantified. The quantitative analysis revealed that mean viral load ranged from ...

2011-01-01

161

Prospects of real-time ion temperature and rotation profiles based on neural-network charge exchange analysis  

Energy Technology Data Exchange (ETDEWEB)

A back-propagation neural network technique is used at JET to extract plasma parameters like ion temperature, rotation velocities or spectral line intensities from charge exchange (CX) spectra. It is shown that in the case of the C VI CX spectra, neural networks can give a good estimation (better than +-20% accuracy) for the main plasma parameters (Ti, V{sub rot}). Since the neural network approach involves no iterations or initial guesses the speed with which a spectrum is processed is so high (0.2 ms/spectrum) that real time analysis will be achieved in the near future. 4 refs., 8 figs.

1994-07-01

162

Picture processing computer to control movement by computer provided vision  

Energy Technology Data Exchange (ETDEWEB)

The author introduces a multiprocessor system which has been specially developed to enable mechanical devices to interpret pictures presented in real time. The separate processors within this system operate simultaneously and independently. By means of freely moveable windows the processors can concentrate on those parts of the picture that are relevant to the control problem. If a machine is to make a correct response to its observation of a picture of moving objects, it must be able to follow the picture sequence, step by step, in real time. As the usual serially operating processors are too slow for such a task, the author describes three models of a special picture processing computer which it has been necessary to develop. 3 references.

1983-01-01

163

Photobioreactor for cultivation and real-time, in-situ measurement of O2 and CO2 exchange rates, growth dynamics, and of chlorophyll fluorescence emission of photoautotrophic microorganisms  

British Library Electronic Table of Contents (United Kingdom)

A detailed knowledge about the dynamics of phytoplanktonic photosynthesis and respiration is crucial for the determination of primary productivity in open oceans as well as for biotechnological applications. The dynamics are best studied in photobioreactors that are able to simulate natural conditions in such, that light can be modulated not only diurnally but also mimicking effects of solar elevation angle from sunrise to sunset, variable cloudiness, light modulation in refractory sun flecks due to water waves, or light intermittence due to turbulent flow in dense suspensions. In addition, high performance photobioreactors ought to be able to monitor in real time photosynthetic and respiratory activities as well as culture growth. Here, we demonstrate performance of a newly designed bench...

2009-01-01

164

Operation of beam line facilities for real-time x-ray studies at Sector 7 of the advanced photon source. Final Report  

Energy Technology Data Exchange (ETDEWEB)

This Final Report documents the research accomplishments achieved in the first phase of operations of a new Advanced Photon Source beam line (7-ID MHATT-CAT) dedicated to real-time x-ray studies. The period covered by this report covers the establishment of a world-class facility for time-dependent x-ray studies of materials. During this period many new and innovative research programs were initiated at Sector 7 with support of this grant, most notably using a combination of ultrafast lasers and pulsed synchrotron radiation. This work initiated a new frontier of materials research: namely, the study of the dynamics of materials under extreme conditions of high intensity impulsive laser irradiation.

2003-09-10

165

Network management of real-time embedded processors  

International Nuclear Information System (INIS)

The Superconducting super Collider Laboratory is a complex of particle accelerators being built in Ellis County, Texas. It will have a dedicated global communications network that will deliver control messages and provide for general data acquisition. This network will connect thousands of computer nodes over a very large geographic area. In order to meet the demanding availability requirements being levied on the system, it will need comprehensive network management. A large number of the computer nodes are embedded systems that traditionally do not support network management services. This presents unique challenges to standard network management practices. The Simple Network Management Protocol, SNMP, is widely accepted by industry as a tool to manage network devices. In this paper the authors examine the performance characteristics and usefulness of an SNMP agent in a real-time environment.

1993-05-17

166

Modular Traffic Sign Recognition applied to on-vehicle real-time visual detection of American and European speed limit signs  

CERN Document Server

We present a new modular traffic signs recognition system, successfully applied to both American and European speed limit signs. Our sign detection step is based only on shape-detection (rectangles or circles). This enables it to work on grayscale images, contrary to most European competitors, which eases robustness to illumination conditions (notably night operation). Speed sign candidates are classified (or rejected) by segmenting potential digits inside them (which is rather original and has several advantages), and then applying a neural digit recognition. The global detection rate is ~90% for both (standard) U.S. and E.U. speed signs, with a misclassification rate 150 minutes of video. The system processes in real-time ~20 frames/s on a standard high-end laptop.

2009-01-01

167

Investigation of the austenite-bainite transformation in gray iron using real time neutron transmission  

Energy Technology Data Exchange (ETDEWEB)

In globulitic gray iron (3.6 wt.% C, 2.4 wt.% Si and 0.45 wt.% Mn) the decomposition of austenite into bainite is investigated in real time using a new method based on neutron scattering. During the phase transformation transmission spectra of thermal neutrons are continuously recorded containing specific Bragg edges. Thus, the transformation is followed in-situ time resolved by evaluating the relative (micro)structural fractions of the transforming phases from the heights of the corresponding Bragg edges. The progression of the transformation is described and the results are discussed. The observed late time deviations from the Avrami law are explained by residual stresses of the second kind (homogeneous microstresses), which occur during the transformation because of the different specific volumes of the phases. ((orig.))

1994-11-30

168

Investigation of the austenite-bainite transformation in gray iron using real time neutron transmission  

International Nuclear Information System (INIS)

In globulitic gray iron (3.6 wt.% C, 2.4 wt.% Si and 0.45 wt.% Mn) the decomposition of austenite into bainite is investigated in real time using a new method based on neutron scattering. During the phase transformation transmission spectra of thermal neutrons are continuously recorded containing specific Bragg edges. Thus, the transformation is followed in-situ time resolved by evaluating the relative (micro)structural fractions of the transforming phases from the heights of the corresponding Bragg edges. The progression of the transformation is described and the results are discussed. The observed late time deviations from the Avrami law are explained by residual stresses of the second kind (homogeneous microstresses), which occur during the transformation because of the different specific volumes of the phases. ((orig.)).

1994-11-01

169

Implementation of an OFDM underwater acoustic communication system on an underwater vehicle with multiprocessor structure  

British Library Electronic Table of Contents (United Kingdom)

Orthogonal frequency division multiplexing (OFDM) can fully use the frequency band and transmit data at high speeds. The ADSP-TS101 is a high performance digital signal processor (DSP) with good properties that include parallel processing and a high speed. Aimed at the real-time processing requirement of the OFDM algorithm, an underwater acoustic communication system with real-time processing capability is carried out. The system is mainly composed of multiple ADSP-TS101s, a multi-channel synchronous sample module and a field programmable gate array (FPGA) chip. The multiprocessor structure is made up of a cluster/data flow associated multiprocessing parallel processing structure as the operation kernel, and a multi-channel synchronous sample module is designed to realize no phase warp amo...

2007-01-01

170

GPS and Google Earth based 3D assisted driving system for trucks in surface mines  

British Library Electronic Table of Contents (United Kingdom)

In order to reduce the number of surface mining accidents related to low visibility conditions and blind spots of trucks and to provide 3D information for truck drivers and real time monitored truck information for the remote dispatcher, a 3D assisted driving system (3D-ADS) based on the GPS, mesh-wireless networks and the Google-Earth engine as the graphic interface and mine-mapping server, was developed at Virginia Tech. The research results indicate that this 3D-ADS system has the potential to increase reliability and reduce uncertainty in open pit mining operations by customizing the local 3D digital mining map, constructing 3D truck models, tracking vehicles in real time using a 3D interface and indicating available escape routes for driver safety.

2010-01-01

171

Flow visualization of liquid metal by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization test.

1994-12-31

172

Flow visualization of liquid metal by neutron radiography  

International Nuclear Information System (INIS)

Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization test.

1994-07-01

173

Experimental optimization of a real time fed-batch fermentation process using Markov decision process.  

Science.gov (United States)

This article describes a methodology that implements a Markov decision process (MDP) optimization technique in a real time fed-batch experiment. Biological systems can be better modeled under the stochastic framework and MDP is shown to be a suitable technique for their optimization. A nonlinear input/output model is used to calculate the probability transitions. All elements of the MDP are identified according to physical parameters. Finally, this study compares the results obtained when optimizing ethanol production using the infinite horizon problem, with total expected discount policy, to previous experimental results aimed at optimizing ethanol production using a recombinant Escherichia coli fed-batch cultivation. (c) 1997 John Wiley & Sons, Inc. Biotechnol Bioeng 55: 317-327, 1997. PMID:18636490

1997-07-20

174

Determination of two-phase natural circulation interfacial parameters by real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigations have been conducted to determine two-phase natural circulation interfacial parameters by real-time neutron radiography. The natural circulation loop used in the present experiments consists of a vertical two-phase section, a gas liquid separator, and a gas injection/heating section. Experiments were performed in a neutron beam for visualization using realtime neutron radiography system. The natural circulation was initiated by injection of known gas flow rate in the heated section. Two-phase flow interfacial parameters including interfacial geometry and phase velocities etc. for bubbly flow and slug flow patterns observed in the experiments will be given in detail. The results indicate that while the natural circulation is largely as expected and that steady stable flows are possible, there are some local phenomena that introduce instabilities due to the interfacial phenomena between the liquid and the gas.

2003-07-01

175

Determination of two-phase natural circulation interfacial parameters by real-time neutron radiography  

International Nuclear Information System (INIS)

Experimental investigations have been conducted to determine two-phase natural circulation interfacial parameters by real-time neutron radiography. The natural circulation loop used in the present experiments consists of a vertical two-phase section, a gas liquid separator, and a gas injection/heating section. Experiments were performed in a neutron beam for visualization using realtime neutron radiography system. The natural circulation was initiated by injection of known gas flow rate in the heated section. Two-phase flow interfacial parameters including interfacial geometry and phase velocities etc. for bubbly flow and slug flow patterns observed in the experiments will be given in detail. The results indicate that while the natural circulation is largely as expected and that steady stable flows are possible, there are some local phenomena that introduce instabilities due to the interfacial phenomena between the liquid and the gas.

2003-10-05

176

Construction and Analytical Application of Internal Amplification Controls (IAC) for Detection of Food Supply Chain-Relevant Viruses by Real-Time PCR-Based Assays  

British Library Electronic Table of Contents (United Kingdom)

Internal amplification controls (IACs) were constructed for incorporation into real-time nucleic acid amplification assays for bovine polyomavirus, hepatitis A virus, hepatitis E virus, human adenovirus, human norovirus genogroup I, human norovirus genogroup II, murine norovirus and porcine adenovirus. The addition of optimised amounts of IAC into the assays did not affect the limits of detection for each specific target virus. A poorly performed extraction of viral nucleic acids was simulated, and the effectiveness of IACs in identifying failed assays was demonstrated. The IACs constructed in this study can be reliably used in their specific assays to provide a robust control that can be routinely applied in the analysis of foods for viruses.

2011-01-01

177

Branching in Amyloid Fibril Growth  

British Library Electronic Table of Contents (United Kingdom)

Using the peptide hormone glucagon and Ab(1-40) as model systems, we have sought to elucidate the mechanisms by which fibrils grow and multiply. We here present real-time observations of growing fibrils at a single-fibril level. Growing from preformed seeds, glucagon fibrils were able to generate new fibril ends by continuously branching into new fibrils. To our knowledge, this is the first time amyloid fibril branching has been observed in real-time. Glucagon fibrils formed by branching always grew in the forward direction of the parent fibril with a preferred angle of 35-40degree. Furthermore, branching never occurred at the tip of the parent fibril. In contrast, in a previous study by some of us, Ab(1-40) fibrils grew exclusively by elongation of preformed seeds. Fibrillation kinetics i...

2009-01-01

178

Asymmetric Totally-corrective Boosting for Real-time Object Detection  

CERN Document Server

Real-time object detection is one of the core problems in computer vision. The cascade boosting framework proposed by Viola and Jones has become the standard for this problem. In this framework, the learning goal for each node is asymmetric, which is required to achieve a high detection rate and a moderate false positive rate. We develop new boosting algorithms to address this asymmetric learning problem. We show that our methods explicitly optimize asymmetric loss objectives in a totally corrective fashion. The methods are totally corrective in the sense that the coefficients of all selected weak classifiers are updated at each iteration. In contract, conventional boosting like AdaBoost is stage-wise in that only the current weak classifier's coefficient is updated. At the heart of the totally corrective boosting is the column generation technique. Experiments on face detection show that our methods outperform the state-of-the-art asymmetric boosting methods.

2010-01-01

179

Application of a prognostic model validation system to real-time dispersion modeling  

Energy Technology Data Exchange (ETDEWEB)

The Atmospheric Release Advisory Capability (ARAC) at the Lawrence Livermore National Laboratory uses the U.S. Navy's Coupled Ocean/Atmosphere Mesoscale Prediction System (COAMPS) to supply high-resolution wind data for use in its real-time dispersion modeling system. ARAC has used COAMPS products to support several events and exercises, and COAMPS forecasts appear accurate, based on qualitative examination. Recently ARAC has developed a quantitative verification system which calculates COAMPS error and bias statistics, comparing COAMPS forecasts of various lengths with observational data. This paper shows how this system has been used to guide ARAC operators, who need an estimate of the likely behavior of COAMPS forecasts of various lengths in different regions, seasons, and weather patterns.

1999-10-18

180

A real-time neutron radiography diagnostic of a vertical co-current two-phase flow channel with a hexagonal finned bundle  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system is developed to determine two-phase flow parameters for a vertical co-current two-phase flow channel with a hexagonal finned bundle. Image processing techniques are applied to visualize the two-phase flow, and procedures for measuring flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution for this complex geometry are discussed. The results show that the experimental flow regime map agrees well with an existing flow regime model for a hexagonal fined bundle. The hexagonal finned bundle is observed to significantly affect the void fraction, void migration, and void fluctuation along the axial flow channel.

2003-06-01

181

Waste monitoring system for effluents  

Energy Technology Data Exchange (ETDEWEB)

The waste monitoring system in use at Los Alamos National Laboratory`s Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system.

1995-07-01

182

The application of virtual instruments technique in U-H_2 experimental system  

International Nuclear Information System (INIS)

The concept of the modern data acquisition system and some functional specialties of the programming software--Visual Basic 6.0 are introduced. The construction and theory of the hardware and the designing principle of the software are described. Experimental results showed that the real-time data acquisition rate was as high as 10 times per second in the system. And the relative standard uncertainty of the measurement was less than 0.5%. (authors)

2004-11-01

183

Studies of neural networks for engine control: application to the electromechanical valves engine; Etudes des reseaux de neurones pour le controle moteur: application a soupapes electromecaniques  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the control of an electromechanical valves engine. The control uses neural networks in order to build a non-linear model of engine filing which depends on the driven inlets. The aim is to build this real-time model and to integrate this model to a control system which performs an iterative inversion. (J.S.)

1997-12-31

184

Si(111)/Gd: A fast and high-resolution thermal neutron detector  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in design and production of thermal neutron detectors based on a crystalline Si diode coupled to a Gd converter are reviewed. The most significant results of neutron test measurements carried out on prototype systems and pointing out the performances of the device are reported. Progress through various detection schemes and technological solutions for the production of a real time neutron counter for routine operation are outlined.

1998-07-01

185

Real-time optical modelling and investigation of inorganic nano-layer growth onto flexible polymeric substrates  

Energy Technology Data Exchange (ETDEWEB)

A major factor for the achievement of the desirable performance, efficiency and lifetime of flexible organic electronic devices is the optimization of the encapsulation layers that protect the device active layers by atmospheric gas molecule permeation. The active layers consisted of small molecule and/or polymer organic semiconductors as well as the organic conductors need to be encapsulated into a transparent medium that will provide the necessary protection and maintain their charge generation and transport characteristics. The encapsulation layers are generally consisted of inorganic thin films (silicon oxide-SiO{sub x} and aluminium oxide-AlO{sub x}) deposited onto the polymeric substrates, such as PolyEthylene Terephthalate (PET). In this work, in situ and real-time Spectroscopic Ellipsometry in the ultraviolet spectral region has been implemented in order to investigate the growth of inorganic SiO{sub x} and AlO{sub x} nano-layers onto PET flexible polymeric ...

2010-01-15

186

Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging  

Energy Technology Data Exchange (ETDEWEB)

Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of the neutrons incident on the object are scattered to the neutron camera, a new neutron beamport facility, with a larger neutron flux (7.3 x 10[sup 7] n/cm[sup 2]/s) than the previous ...

1992-01-01

187

Real time neutron diffraction experiments using Bragg edges  

Energy Technology Data Exchange (ETDEWEB)

Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.

1995-12-31

188

Real time neutron diffraction experiments using Bragg edges  

International Nuclear Information System (INIS)

Time resolved phase transition and strain experiments have been performed on the millisecond time scale using a Bragg-edge transmission technique that has been developed at the Los Alamos National Laboratory. The precision with which lattice parameters can be determined from edge positions is sufficient to perform high-resolution strain measurements in uniaxial stress.

1994-12-02

189

Proton-Transfer-Reaction Mass Spectrometry as a New Tool for Real Time Analysis of Root-Secreted Volatile Organic Compounds in Arabidopsis1  

UK PubMed Central (United Kingdom)

Plant roots release about 5% to 20% of all photosynthetically-fixed carbon, and as a result create a carbon-rich environment for numerous rhizosphere organisms, including plant pathogens and symbiotic...Full Text Available

2004-05-01

190

Plagiarism Detection in arXiv  

CERN Document Server

We describe a large-scale application of methods for finding plagiarism in research document collections. The methods are applied to a collection of 284,834 documents collected by arXiv.org over a 14 year period, covering a few different research disciplines. The methodology efficiently detects a variety of problematic author behaviors, and heuristics are developed to reduce the number of false positives. The methods are also efficient enough to implement as a real-time submission screen for a collection many times larger.

2007-01-01

191

Patient Monitoring during Mechanotherapy Based on Electrocutaneous Impedance Measurement  

British Library Electronic Table of Contents (United Kingdom)

Patient monitoring during mechanotherapy based on electrocutaneous impedance measurement is discussed. Methods implemented by the Alpharhythmica computer-assisted system are described. Mechanotherapy modifies electrocutaneous impedance as compared to other parameters: heart rate, arterial pressure, and body temperature. Real time criteria of mechanotherapy efficacy based on electrocutaneous impedance measurement are suggested. Results of electrocutaneous impedance monitoring are presented.

2011-01-01

192

Optimization of the availability-safety pair for propulsion boilers; Optimisation du couple, disponibilite - surete pour les chaufferies de propulsion  

Energy Technology Data Exchange (ETDEWEB)

The relations between nuclear energy availability and nuclear plant safety are analyzed in the particular cases of naval propulsion nuclear boilers (aircraft carriers, submarines): safety objectives, present and potential risk analysis, optimization of the availability-safety couple, at the design stage and during operation (procedural rules related to the boiler state, real time decisions). 6 fig., 1 tab.

1994-12-31

193

Non-supersymmetric deformations of non-critical superstrings  

Energy Technology Data Exchange (ETDEWEB)

We study certain supersymmetry breaking deformations of linear dilaton backgrounds in different dimensions. In some cases, the deformed theory has bulk closed strings tachyons. In other cases there are no bulk tachyons, but there are localized tachyons. The real time condensation of these localized tachyons is described by an exactly solvable worldsheet CFT. We also find some stable, non-supersymmetric backgrounds.

2005-12-15

194

Neutron-computer tomography using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique ...

1986-01-01

195

Neutron-computer tomography using real-time neutron radiography  

International Nuclear Information System (INIS)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution ...

1986-01-01

196

Neutron radiography with the cyclotron, 6  

International Nuclear Information System (INIS)

The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).

1988-01-01

197

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

198

Monte Carlo design calculations for a neutron imaging facility collimator  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.

1996-12-31

199

Monitoring drinking water networks by data telemanagement; Telegestion de datos para control de redes de agua potable  

Energy Technology Data Exchange (ETDEWEB)

The WIT telemanagement system simply, reliably and efficient by makes available to us in real time processed, ordered and managed data. Such information has been used to optimise the performance of the drinking water distribution networks on a number of housing estates. This has led to major saving in consumption and on equipment maintenance, thereby improving customer service and obtaining a more rational use of piped water. (Author)

1997-04-01

200

Measurements of nuclear emulsion tracks by means of a picture analysis system  

Energy Technology Data Exchange (ETDEWEB)

A semiautomatic system for measurements of nuclear tracks in nuclear emulsion is described. The microscopic image of a particle track is picked up by a video camera. The video picture is digitized in real time. The picture analysis is done via software. The microscope is equipped with a stepping motor driven stage which is also computer-controlled.

1986-01-01

201

Introduction to the RCS thermal-hydraulic model of the full scope simulator of Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

Both the accuracy and real-time are quite strictly required for the RCS thermal-hydraulic model of the simulation of nuclear power station. So, a large amount of reasonable simplifications should be carried on. The author introduces the RCS thermal-hydraulic model of the full scope simulator of Daya Bay Nuclear Power Station, and emphasizes on the fundamental hypotheses and computation method of its kernel part--DEFI programme.

202

Interventional Procedures in Superficial Lesions: The Value of 2D with Additional Coronal Reformatted 4D Ultrasonography Guidance  

UK PubMed Central (United Kingdom)

ObjectiveWe wanted to assess the usefulness of four-dimensional (4D) ultrasonography (US), i.e., real-time three-dimensional US, as an adjunct for performing various US-guided interventional...Full Text Available

2006-01-01

203

Implementation and laboratory test results for an adaptive Power System Stabilizer based on linear optimal control  

Energy Technology Data Exchange (ETDEWEB)

Implementation of an adaptive power system stabilizer (PSS) based on linear optimal control is described in this paper. The generator is identified in real time, and a special 3rd order discrete Riccati equation is solved in each sample interval. Because the output of the generator is fed back directly, the controller can track the system very fast. Experimental studies on a physical model of a power system demonstrate the effectiveness of the proposed adaptive optimal controller.

1990-12-01

204

HORIZON SENSING (PROPOSAL NO.51)  

Energy Technology Data Exchange (ETDEWEB)

Real-time horizon sensing on continuous mining machines is becoming an industry tool. Installation and testing of production-grade Horizon Sensor (HS) systems continued this quarter at Monterey Coal Company (ExxonMobil), Mountain Coal Company West Elk Mine (Arch), and Ohio Valley Coal Company (OVC). Monitoring of system function, user experience, and mining benefits is ongoing. All horizon sensor components have finished MSHA (U.S.) and IEC (International) certification.

2003-07-01

205

Electric loading of power transmission lines - statistical methodology and real time management; Carregamento eletrico de linhas de transmissao - metodologia estatistica e gerenciamento em tempo real  

Energy Technology Data Exchange (ETDEWEB)

This paper shows a computerized system, that adopt a statistical methodology and simultaneous measurements of wind velocity and environment temperature, as an experiences at the power transmission lines with environmental monitoring systems. 9 figs., 16 refs.

1991-12-31

206

Distributed multiprocessor system runs on 68000-based VME bus hardware  

Energy Technology Data Exchange (ETDEWEB)

Using the Philips DRM distributed real-time multiprocessing system, designers can implement high-performance computer systems using VME hardware and the C programming language. The system provides a virtual-processing environment in which several 68000 CPUs share the workload. There are no centralized components, and tasks can be assumed by the rest of a system in the event of an individual processor's failure.

1984-04-19

207

Development on astable multivibrators using the combination of linear and non-linear materials as switching elements based on all optial method  

Science.gov (United States)

In this communication we propose a method to implement an all-optical astable multivibrator using the non-linear material based switches and logic gates. The scheme can operate in real time. The delay time can achieve ps(pico-second). The pulse duration can be made very low and may cross the THz easily by selecting proper material and laser source.

2009-03-01

208

Development of a site-specific following accident dose assessment system  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this project to interface the site-specific real-time radiological dose assessment system FADAS(Following Accident Dose Assessment System) to CARE. In this study, the results of the field tracer experiments conducted on the Younggwang site have been analysed. And the experimental procedure on Ulchin site has been introduced. The environmental characteristics on Ulchin and Wolsung has been investigated.

1997-12-15

209

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

210

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

211

Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques  

International Nuclear Information System (INIS)

In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.

2010-06-01

212

Detection of Shiga Toxin-Producing Escherichia coli Serotypes O26:H11, O103:H2, O111:H8, O145:H28, and O157:H7 in Raw-Milk Cheeses by Using Multiplex Real-Time PCR ?  

UK PubMed Central (United Kingdom)

Shiga toxin (Stx)-producing Escherichia coli (STEC) strains are a diverse group of food-borne pathogens with various levels of virulence for humans. In this study, we describe the use...Full Text Available

2011-03-01

213

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.

1999-09-01

214

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

International Nuclear Information System (INIS)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere

1999-06-06

215

Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography  

UK PubMed Central (United Kingdom)

AimsTwo-dimensional echocardiographic (2DE) continuity-equation derived aortic valve area (AVA) in aortic stenosis (AS) relies on non-simultaneous measurement of left ventricular...Full Text Available

2008-10-01

216

Ancillary Services in a pool-based competitive market: Conference on innovative approaches to electricity pricing  

Energy Technology Data Exchange (ETDEWEB)

(1) Most ancillary services needed for real-time control of the transmission grid and to meet operating criteria can be competitively supplied and competitively procured. (2) The independent service operator (ISO) must directly control the generators and loads, which supply ancillary services. (3) Comparability of access to ancillary services is achievable through the ISO-based competitive market structure.

1996-03-01

217

An architecture for device independent interfacing  

Energy Technology Data Exchange (ETDEWEB)

Achieving device independence for software applications is required for all but a small number of critical real time applications. Device independence is achieved by establishing protocols and building protocol interpreters for the specific devices. Data structures containing pointers to functions provide a flexible architecture for implementing protocol translation. 3 refs., 5 figs.

1990-01-01

218

A submillimeter wavelength space-based imaging radar  

Science.gov (United States)

This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.

1988-05-01

219

A rapid and simple DNA extraction procedure to detect Salmonella spp. and Listeria monocytogenes from fresh produce using real-time PCR  

Science.gov (United States)

DNA isolation procedures significantly influence the outcome of PCR-based detection of human pathogens. Unlike clinical samples, DNA isolation from food samples such as fresh and fresh-cut produce has remained a formidable task and has hampered the sensitivity and accuracy of molecular methods. We...

220

A non-invasive approach for the determination of rumen pH  

Environmental Research Database

DescriptionAt present, measurement of rumen pH for differnt diets and feeding regimes is only possible through direct sampling of the rumen fluid. Such invasive procedures are not practical at the farm level and they have ethical implications for research programmes. This approach also has limitations to its reliability due to spatial variations in acidity within the rumen. Mathematical modelling offers a non-invasive real-time alternative for monitoring rumen pH, and the purpose of the research propose [continued...

2004-01-31

221

A Real-Time US Army Tactical Telephone Network ...  

Science.gov (United States)

... To CA 2 TOM 2 L= DTO 2 4 9"ylem 2 a Systsm2OTO 3 Figure 25: Node I C-5 Internal Connectivity C5 DTO 2 GM I sy~stm I 1 RC-IOS L3 To CA ...

1993-09-01

222

REVERSAL LEARNING SET AND FUNCTIONAL EQUIVALENCE IN CHILDREN WITH AND WITHOUT AUTISM  

UK PubMed Central (United Kingdom)

To evaluate whether children with and without autism could exhibit (a) functional equivalence in the course of yoked repeated-reversal training and (b) reversal learning set, 6 children, in...Full Text Available

2008-01-01

223

Human Immunodeficiency Virus type-1 reverse transcriptase exists as post-translationally modified forms in virions and cells  

UK PubMed Central (United Kingdom)

BackgroundHIV-1 reverse transcriptase (RT) is a heterodimer composed of p66 and p51 subunits and is responsible for reverse transcription of the viral RNA genome into DNA. RT can...Full Text Available

228

Visualization of direct contact heat transfer between water and molten alloy  

Energy Technology Data Exchange (ETDEWEB)

We have been developing an innovative Steam Generator concept of Fast Breeder Reactors by using liquid-liquid direct contact heat transfer. In this concept, the SG shell is filled with a molten alloys, which is heated by primary sodium. Water is fed into the high temperature molten alloy, and evaporates by direct contact heating. In order to obtain the fundamental information to discuss the heat transfer mechanisms of the direct contact between the water and the alloy, this phenomenon was visualized by real-time neutron radiography. JRR-3M real-time thermal neutron radiography in Japan Atomic Energy Research Institute was used. Followings are main results. (1) The vigorous evaporation occurs in the molten alloy. This phenomena is different from the known phenomenon such as the evaporation of refrigerant R-113 in the water. (2) The evaporation in the bubble has finished in a moment due to high heat transfer performance between the liquid and ...

1996-06-01

229

Visualization of a gas-liquid metal two-phase natural circulation flow by a real-time neutron radiography technique  

Energy Technology Data Exchange (ETDEWEB)

In a breeder-type nuclear power plant, liquid metal is used as a coolant due to the high heat capacity factor. Also, some proposals for fusion reactor blanket design include liquid metal as a possible coolant. In both cases the understanding of natural circulation of liquid-metal flow behavior is an integral part of the thermal hydraulic analysis, especially under two-phase flow conditions. Experimental investigations have been conducted to study a liquid metal two-phase natural circulation flow system. A lead-bismuth (PbBi) eutectic mixture is used as a working fluid in a heated metal walled natural circulation loop. Gas injection induces natural circulation through the gas-lift mechanism. A real-time neutron radiography system is used to visualize the two-phase mixture, specifically the interface and the flow regime. Measurements of void fraction, void fluctuation and bubble propagation are performed.

1996-06-01

230

Visualization of a gas-liquid metal two-phase natural circulation flow by a real-time neutron radiography technique  

International Nuclear Information System (INIS)

In a breeder-type nuclear power plant, liquid metal is used as a coolant due to the high heat capacity factor. Also, some proposals for fusion reactor blanket design include liquid metal as a possible coolant. In both cases the understanding of natural circulation of liquid-metal flow behavior is an integral part of the thermal hydraulic analysis, especially under two-phase flow conditions. Experimental investigations have been conducted to study a liquid metal two-phase natural circulation flow system. A lead-bismuth (PbBi) eutectic mixture is used as a working fluid in a heated metal walled natural circulation loop. Gas injection induces natural circulation through the gas-lift mechanism. A real-time neutron radiography system is used to visualize the two-phase mixture, specifically the interface and the flow regime. Measurements of void fraction, void fluctuation and bubble propagation are performed.

1996-03-10

231

Two-phase flow regime observations in a vertical hexagonal flow channel with and without a finned fuel bundle  

International Nuclear Information System (INIS)

Previous flow regime studies have been for horizontal, vertical, and inclined pipe flow. As such, only a few studies have been performed on bundle geometries. The present paper examines the flow regimes for a vertical hexagonal flow channel with and without a finned fuel bundle. This type of a 36 finned rod hexagonal fuel bundle in parallel hexagonal flow channels is used in a MAPLE (Multi- purpose Applied Physics Lattice Experimental) type nuclear reactor. An experiment apparatus was designed consisting of the flow channel, inlet plenum and an air-water separator. The inlet plenum is used to provide a uniform mixture of air and water before entering the hexagonal flow channel. A turbine flow meter is used to determine the water flow rate. The turbine flow meter is calibrated for a low flow range and limits the measurable flow to 50 l/min. Flow pattern observation is determined by a SONY video camera, Real-Time Neutron Radiography, pressure transducer and ...

1990-12-10

232

Tissue equivalent proportional counter real time neutron monitor  

International Nuclear Information System (INIS)

The Tissue Equivalent Proportional Counter (TEPC) was developed to monitor low level neutron exposure rates at working stations in a nuclear fuel fabrication facility. It has proven capable of accurately measuring neutron dose rates at levels from 0.1 to 0.2 mrem/hr. It also calculates the Quality Factor which is of importance in locations where the neutron to gamma ratio may vary significantly and irregularily. The system described is computerized to monitor 100 work locations simulationeously and can be expanded to monitor 384 locations. Neutron dose is accumulated on a real time basis and after the proton drop point is established, dose rate can be read out at any time for the dose accumulated over a specified period of time. The current development program which provides reduced system maintenance, lower detection limits, and improved accuracy is discussed along with examples of measurement data and work experience with the current system.

1978-10-25

233

System suitable for use in neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A refrigerated beryllium filter can be used to effectively eliminate ...

1990-02-07

234

System suitable for use in neutron radiography  

International Nuclear Information System (INIS)

A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A refrigerated beryllium filter can be used to effectively eliminate ...

1988-07-20

235

Study of building materials impregnation processes by quasi-real-time neutron radiography  

International Nuclear Information System (INIS)

Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be presented. Quantitative results obtained by NR ...

1999-11-03

236

Solid-state amorphization of a quenched high-pressure GaSb phase studied by real-time neutron diffraction: evolution of the crystalline phase  

Energy Technology Data Exchange (ETDEWEB)

The amorphization of a quenched sample of the GaSb-II high-pressure phase was studied at ambient pressure by real-time neutron diffraction in the course of the sample heating from 100 K to room temperature at a rate of 0.4 K min{sup -1}. The transformation to the amorphous state begins at 140 K and is completed near room temperature. The {beta}-Sn type structure was shown to represent only the mean lattice of the high-pressure GaSb-II phase. The superstructure of this phase widely varied with temperature and is caused by the ordered displacement of atoms. The temperature range of the metastable crystalline phase relaxation is divided into three intervals according to the temperature dependence of the tetragonality ratio (c/a). At the boundaries of these temperature intervals, i.e. temperatures T = 170 and 230 K, two second-order phase transitions are observed. Anomalous heat and volumetric effects were observed earlier by means of calorimetry and dilatometry in the ...

2009-01-28

237

Solid-state amorphization of a quenched high-pressure GaSb phase studied by real-time neutron diffraction: evolution of the crystalline phase  

International Nuclear Information System (INIS)

The amorphization of a quenched sample of the GaSb-II high-pressure phase was studied at ambient pressure by real-time neutron diffraction in the course of the sample heating from 100 K to room temperature at a rate of 0.4 K min-1. The transformation to the amorphous state begins at 140 K and is completed near room temperature. The ?-Sn type structure was shown to represent only the mean lattice of the high-pressure GaSb-II phase. The superstructure of this phase widely varied with temperature and is caused by the ordered displacement of atoms. The temperature range of the metastable crystalline phase relaxation is divided into three intervals according to the temperature dependence of the tetragonality ratio (c/a). At the boundaries of these temperature intervals, i.e. temperatures T = 170 and 230 K, two second-order phase transitions are observed. Anomalous heat and volumetric effects were observed earlier by means of calorimetry and dilatometry in the same ...

2009-01-28

238

Real-time management of water quality in the San Joaquin River Basin, California.  

Energy Technology Data Exchange (ETDEWEB)

In the San Joaquin River Basin, California, a realtime water quality forecasting model was developed to help improve the management of saline agricultural and wetland drainage to meet water quality objectives. Predicted salt loads from the water quality forecasting model, SJRIODAY, were consistently within +- 11 percent of actual, within +- 14 percent for seven-day forecasts, and with in +- 26 percent for 14-day forecasts for the 16-month trial period. When the 48 days dominated by rainfall/runoff events were eliminated from the data set, the error bar decreased to +- 9 percent for the model and +- 11 percent and +- 17 percent for the seven-day and 14-day forecasts, respectively. Constraints on the use of the model for salinity management on the San Joaquin River include the number of entities that control or influence water quality and the lack of a centralized authority to direct their activities. The lack of real-time monitoring sensors for other primary ...

1997-09-01

239

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-11

240

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-01

241

Real-Time Price Discovery in Global Stock, Bond and Foreign Exchange Markets  

DEFF Research Database (Denmark)

Using a unique high-frequency futures dataset, we characterize the response of U.S., German and British stock, bond and foreign exchange markets to real-time U.S. macroeconomic news. We find that news produces conditional mean jumps; hence high-frequency stock, bond and exchange rate dynamics are linked to fundamentals. Equity markets, moreover, react differently to news depending on the stage of the business cycle, which explains the low correlation between stock and bond returns when averaged over the cycle. Hence our results qualify earlier work suggesting that bond markets react most strongly to macroeconomic news; in particular, when conditioning on the state of the economy, the equity and foreign exchange markets appear equally responsive. Finally, we also document important contemporaneous links across all markets and countries, even after controlling for the effects of macroeconomic news.

2007-01-01

242

Neutron radiography with the cyclotron, 4  

International Nuclear Information System (INIS)

A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented together with some actual application to dynamical fluid motion of ...

1986-01-01

243

MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local void distribution ...

2002-07-01

244

MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography  

International Nuclear Information System (INIS)

The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local void distribution ...

2002-08-11

245

Investigation of large amplitude stratified waves in a CANDU-type 37 rod nuclear fuel channel by a real-time neutron radiography technique  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a CANDU-type 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the CANDU-type rod bundles. A new flow regime is observed and designated Large Amplitude Stratified Wavy flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occurring in the bundle. The rods in the bundle may act as a dampener to the vertical flow and hinders the development of the wave into plug or slug flow by changing the momentum of the fluid in the circumferential direction. The effect of ...

1997-12-31

246

Investigation of large amplitude stratified waves in a CANDU-type 37 rod nuclear fuel channel by a real-time neutron radiography technique  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a cylindrical 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the cylindrical rod bundles. A new flow regime is observed and designated large amplitude stratified wavy (LASW) flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occuring in the bundle. The rods in the bundle may act as a dampener to the vertical flow component and hinders the development of the wave into plug or slug flow by changing the momentum of the fluid in the circumferential ...

2000-08-01

247

Investigation of large amplitude stratified waves in a CANDU-type 37 rod nuclear fuel channel by a real-time neutron radiography technique  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system is used to determine two-phase flow parameters for a horizontal co-current two-phase flow channel with a CANDU-type 37 rod bundle. Image processing techniques are applied to visualize the two-phase flow, and to determine flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution. The experimentally determined flow regime map disagrees with existing flow regime models developed for the CANDU-type rod bundles. A new flow regime is observed and designated Large Amplitude Stratified Wavy flow. The results show that the LASW flow regime may be due to a combination of undeveloped flow phenomena, boundary conditions, and circumferential cross flow occurring in the bundle. The rods in the bundle may act as a dampener to the vertical flow and hinders the development of the wave into plug or slug flow by changing the momentum of the fluid in the circumferential direction. The effect of ...

1997-10-04

248

Integration of turbo-generator modules in digital transient network analyzer  

Science.gov (United States)

The behavior of a small power system consisting of two interconnected generators is simulated in real-time by a prototype Digital Transient Network Analyzer (TNA). The prototype Digital TNA consists of two Computational Modules and one I/O Module. The Modules communicate with each other through ribbon cables. Each Computational Module simulates one Turbo-Generator, its Transformer, its Governor, Exciter, and Power System Stabilizer Systems. The numerical integration is shared by two TMS320C30 DSPs at a step-size of 100 microseconds in real-time. The I/O module post-processes the state variables and presents selected information for analog display. The paper presents oscillograms from a test program which includes symmetry checks and behavioral checks against well known waveforms of hunting oscillations, synchronization out-of-phase torques, and subsynchronous resonance phenomena. The success of the Digital TNA depends on: (a) the theoretical ...

1994-05-01

249

In situ thermal desorption of H{sub 2} from LiNH{sub 2}-2LiH monitored by environmental SEM  

Energy Technology Data Exchange (ETDEWEB)

This article describes in situ heating and observation of a LiNH{sub 2}-2LiH mixture in an environmental scanning electron microscope (ESEM). The LiNH{sub 2}-2LiH mixture showed extensive morphological changes with heating and attendant hydrogen desorption. Static images and real-time movies were obtained during the dehydrogenation process. H{sub 2} evolution commences at {proportional_to}150 C (LiNH{sub 2} + 2LiH {yields} Li{sub 2}NH + H{sub 2} + LiH), and continues until {proportional_to}410 C. Dramatic morphological changes are observed at 220 and 410 C (Li{sub 2}NH + LiH {yields} Li{sub 3}N + H{sub 2}). The material converts to a microcrystalline phase at higher temperatures (>500 C). The observed H{sub 2} desorption and morphological changes occur at temperatures in good agreement with those measured by complementary analytical methods. This is the first time the major structural and morphological changes attendant on H{sub 2} loss from this system have ...

2009-01-15

250

Fluid flow visualization with neutron radiography. [Using collimated beam of neutrons  

Energy Technology Data Exchange (ETDEWEB)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging techniques such as real-time video, high speed video, and ...

1991-01-01

251

Fluid flow visualization with neutron radiography  

International Nuclear Information System (INIS)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging techniques such as real-time video, high speed video, and ...

1764-01-01

252

Finned fuel element two-phase flow parameter measurements using real-time neutron radiography  

International Nuclear Information System (INIS)

The measurement of two-phase flow parameters and development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with R134a Freon as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local void ...

2007-04-22

253

Finned fuel element two-phase flow parameter measurements using real-time neutron radiography  

International Nuclear Information System (INIS)

The measurement of two-phase flow parameters for development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with Freon 134a as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer present. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local ...

2008-02-01

254

Expert overseer for mass spectrometer system  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The overseer has the capability ...

1991-06-18

255

Expert overseer for mass spectrometer system  

International Nuclear Information System (INIS)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The overseer has the capability ...

1989-04-04

256

ETHERNET BASED EMBEDDED SYSTEM FOR FEL DIAGNOSTICS AND CONTROLS  

Energy Technology Data Exchange (ETDEWEB)

An Ethernet based embedded system has been developed to upgrade the Beam Viewer and Beam Position Monitor (BPM) systems within the free-electron laser (FEL) project at Jefferson Lab. The embedded microcontroller was mounted on the front-end I/O cards with software packages such as Experimental Physics and Industrial Control System (EPICS) and Real Time Executive for Multiprocessor System (RTEMS) running as an Input/Output Controller (IOC). By cross compiling with the EPICS, the RTEMS kernel, IOC device supports, and databases all of these can be downloaded into the microcontroller. The first version of the BPM electronics based on the embedded controller was built and is currently running in our FEL system. The new version of BPM that will use a Single Board IOC (SBIOC), which integrates with an Field Programming Gate Array (FPGA) and a ColdFire embedded microcontroller, is presently under development. The new system has the features of a low ...

2006-10-24

257

Dynamic Rating and Underground Monitoring System (DRUMS)  

Energy Technology Data Exchange (ETDEWEB)

Drums is an acronym for Dynamic Rating and Underground Monitoring System, with specific application to high-pressure pipe-type cable systems which are the predominant means of underground electric power transmission in the United States. The primary objective of this EPRI-sponsored feasibility study was to establish the technical feasibility of seven DRUMS functions and two novel DRUMS communication schemes. The seven DRUMS functions which monitor the system's vital and measurable parameters in real time and perform system diagnostics in the event of component deterioration, malfunction or failure are: Real Time Current Monitoring and Rating; Leak Detection and Location; Fault Location; Pothead Monitoring; Oil Monitoring; Pipe Protection; and Splice Monitoring. The two DRUMS communication schemes are internal to the pipe cable system. Mechanical Communication will use pressure pulses to ...

1991-07-01

258

Determination of time-dependent void fraction distribution in bubbly two-phase flow by a real-time neutron radiography technique  

Energy Technology Data Exchange (ETDEWEB)

Radiographic images generated by the real-time neutron radiography system (RTNR) are analyzed by customized image processing software of the determination of instantaneous void fraction distribution. The cross-sectional averaged axial void fraction profiles and the two-dimensional void fraction profiles are determined simultaneously for each image. Various flow regimes are generated to determine if the RTNR system can accurately predict the void distribution in the radial, axial, and temporal coordinates. The results show the RTNR system correctly determines the void fraction distribution for each flow regime; however, accuracy decreases with decreasing void fraction. For net water thicknesses > 1.0 cm, the accuracy decreases with increasing water thickness due to the extreme sensitivity of thermal neutron interactions with light water. Heavy water is a more suitable fluid than light water for void fraction measurements in large-diameter flow systems.

1995-01-01

259

Design of multifunction anti-terrorism robotic system based on police dog  

Science.gov (United States)

Aimed at some typical constraints of police dogs and robots used in the areas of reconnaissance and counterterrorism currently, the multifunction anti-terrorism robotic system based on police dog has been introduced. The system is made up of two parts: portable commanding device and police dog robotic system. The portable commanding device consists of power supply module, microprocessor module, LCD display module, wireless data receiving and dispatching module and commanding module, which implements the remote control to the police dogs and takes real time monitor to the video and images. The police dog robotic system consists of microprocessor module, micro video module, wireless data transmission module, power supply module and offence weapon module, which real time collects and transmits video and image data of the counter-terrorism sites, and gives military attack based on commands. The system ...

2007-11-01

260

Demonstration of mobile accelerator neutron radiography for in situ detection of moisture and corrosion in aircraft structures  

Energy Technology Data Exchange (ETDEWEB)

A demonstration of the first mobile 'on-off' neutron radiography system, developed by Vought Corporation Advanced Technology Center, has been conducted at McClellan Air Force Base. On-site neutron radiography operations with the engineering model were carried out to demonstrate the potential of such a system for in situ detection of hidden moisture and corrosion in aircraft structures, and to assess the performance of the unique hardware system in a depot environment. Inspections were performed on F-111 and F-106 aircraft, and several structures removed from T-39 and A-10 aircraft were also inspected. The effectiveness of the new N-ray system for imaging moisture and corrosion was confirmed after subsequent removal of skins from some of the F-111 structures. Excellent correlation of radiographic images with actual moisture and corrosion damage was attained. Both film and real time/near real ...

1983-01-01

261

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent System is ...

1988-10-01

262

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

263

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

264

Clinical-HINTS: integrated intelligent ICU patient monitoring and information management system.  

Science.gov (United States)

Clinical-HINTS (Health Intelligence System) is a horizontally integrated decision support system (DSS) designed to meet the requirements for intelligent real-time clinical information management in critical care medical environments and to lay the foundation for the development of the next generation of intelligent medical instrumentation. The system presented was developed to refine and complement the information yielded by clinical laboratory investigations, thereby benefiting the management of the intensive care unit (ICU) patient. More specifically, Clinical-HINTS was developed to provide computer-based assistance with the acquisition, organisation and display, storage and retrieval, communication and generation of real-time patient-specific clinical information in an ICU. Clinical-HINTS is an object-oriented system developed in C+2 to run under Microsoft Windows as an embryo intelligent agent. Current generic reasoning skills include ...

1997-01-01

265

Application of neutron diffraction in chemistry. Pt. 2  

Energy Technology Data Exchange (ETDEWEB)

This article provides a survey of neutron scattering experiments in condensed matter research, which are of interest to chemistry. The theoretical background has been treated in a previous issue. The present article consists of two parts. The first part exhibits the range of experimental possibilities by means of a few selected examples. The starting point is classical neutron diffraction by which the position of atomic nuclei may be determined. Additional information on the spatial distribution in the outer electron shells may be obtained via combined X-ray/neutron-diffraction experiments or via the diffraction of polarized neutrons. Progress in instrumentation, due to the development of more intense sources, has influenced especially the fields of small angle scattering and spectroscopy. The second part features domains of research of current interest, where a combination of several neutron scattering techniques may prove to be necessary. Thus, the kinetics of structural processes ...

1982-01-01

266

Analysis of lightning fault detection, location and protection on short and long transmission lines using Real Time Digital Simulation  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to present an analysis of lightning fault detection, location and protection using numeric distance relays applied in high voltage transmission lines, more specifically in the 500 kV transmission lines of CEMIG (Brazilian Energy Utility) between the Vespasiano 2 - Neves 1 (short line - 23.9 km) and Vespasiano 2 - Mesquita (long line - 148.6 km) substations. The analysis was based on the simulations results of numeric distance protective relays on power transmission lines, realized in September 02 to 06, 2002, at Siemens AG's facilities (Erlangen - Germany), using Real Time Digital Simulator (RTDS{sup TM}). Several lightning faults simulations were accomplished, in several conditions of the electrical power system where the protective relays would be installed. The results are presented not only with the times of lightning faults elimination, but also all the functionality of a protection system, including ...

2007-07-01

267

A summary of neutron radiography and neutron radioscopy applications at the University of Michigan Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray imaging, flow in porous media, ...

1992-03-01

268

Visualization of two-phase flow eddies in rectangular channels using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Bubbly and slug flows have been analyzed using the afore-mentioned techniques. An image series of bubbly-slug flow is shown. The image separation time is 17 ms, and the total flow length is {approx} 10 cm. A circular eddy pattern that follows the slug can be readily seen and tracked, although reliability is low due to motion in the transverse direction. This motion also adds considerable error to the velocity measurements using image recognition technique. This will increase the reliability and accuracy of the tracking method.

1994-12-31

269

Visualization and void fraction measurements of refrigerant flow in a refrigerator by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

The refrigerant two-phase flows in a distributor and a simulated plate heat exchanger with a single passage used in a compression-type refrigerator were visualized by real-time neutron radiography. For a distributor, the liquid fraction in the each tube was measured by some image processing method. On the other hand, for a plate heat exchanger, the two-dimensional distribution of void fraction was measured quantitatively by the umbra method. As a result, it was shown that the dynamic behaviors of refrigerant at the inlet of the section strongly affected on the performance, that is, a distribution performance of a distributor and a liquid distribution in a plate heat exchanger. (author)

2000-07-01

270

Use of real-time Fourier Transform Infrared Reflectivity as an in situ monitor of YBCO film growth and processing  

CERN Document Server

Fourier Transform Infrared (FTIR) spectroscopy has been utilized during high rate E-beam evaporation/deposition of YBa2Cu3O7 (YBCO). The results demonstrate the great utility of FTIR as an in situ monitor of YBCO deposition and processing. We detect different (amorphous/fine polycrystalline) insulating pre-existing phases to the high Tc superconducting phase which appear to have distinct reflectivity fingerprints dominated by thin film interference effects, as a function of temperature and oxygen pressure. These fingerprints reveal some of the kinetic and thermodynamic pathways during the growth of YBCO.

2007-01-01

271

The CTOF measurements and Monte Carlo analyses of neutron spectra for backward direction from iron target irradiated by protons with energies from 400 to 1200 MeV  

CERN Document Server

A calorimetric-time-of-flight (CTOF) technique was used for real-time, high-precision measurement of neutron spectrum at the angle of 175 degrees from the initial proton beam direction, which hits a face plane of a cylindrical iron target of 20 cm in diameter and 25 cm thick. A comparison was performed between the neutron spectra predicted by the MARS and the MCNPX code systems and measured by experiments for 0.4-, 0.6-, 0.8-, 1.0-, and 1.2-GeV protons.

2009-01-01

272

THE DEVIL AND CUSTOMER RELATIONSHIP MANAGEMENT  

British Library Electronic Table of Contents (United Kingdom)

The paper takes as its starting point the diffusion of ICT applications associated with so-called 'customer relationship management' (CRM). CRM encourages organisations to shift their understanding of customers from an episodic and transaction-based perspective to one that emphasises continuous 'relationship management'. CRM applications thus promise to deliver more, real-time accurate information about consumer habits and behaviours therefore allowing organisations to maximise their extraction of business value. This paper explores the ways in which such inscriptive technologies are not merely referential but also constitutive of contemporary re-presentations and ideals of the consuming subject. Focusing on what we might call the 'digital doubles' of customer relationship management the a...

2010-01-01

273

Some reflections on the network power plant interaction  

International Nuclear Information System (INIS)

The layout of the network with its frequency and transmission power control shows how the time behaviour of power plants and consumers determines the frequency curve during sudden power disturbances. As for switching processes in the network for the turbine, network operation entails loads due to shock-like disturbance functions to which one should not normally respond by switching off. The interception controllers are therefore adjusted via a simulation model by which the vibrations of the turbine rotor can be modelled in real time under different network loads. (GL).

1978-11-24

274

Simulation of non-linear and switching elements for transient analysis based on wave digital filters  

Science.gov (United States)

A previous paper introduced the use of wave digital filters as a basic building block for power system simulation, particularly suitable for real-time applications. This paper stresses the simulation of non-linear and switching elements, emphasizing the advantages of the wave filters implementation. The digital structure is maintained even when non-linear components change their characteristics or power electronic devices switch their states. As a very important by-product, the suppression of numerical oscillations related to the trapezoidal rule is achieved in a rather simple way, with no effects on simulation results.

1996-10-01

275

SIRIO: Computer system for the follow up and the optimum planning of short time exploitation of a hydroelectric system; SIRIO: sistema informatico para el seguimiento y la programacion optima de la explotacion a corto plazo de un sistema hidroelectrico  

Energy Technology Data Exchange (ETDEWEB)

Sirio is a computerized application to manage the hydroelectric system in a short time. This management is implemented as a real time tool in the Control Department. SIRIO has many modules, independent and integrated to operate and perform the data acquisition, optimization, planning simulation and planning optimization. This article presents the SIRIO System and its applications to the Iberdrola system in Tajo river.

1994-12-31

276

Response to 'Comment on 'Experimental observation of carbon dioxide reduction in exhaust gas from hydrocarbon fuel burning'' [Phys. Plasmas 17, 014701 (2010)  

International Nuclear Information System (INIS)

A high-voltage cathode initiates an electron emission, resulting in a reduction in the carbon dioxide concentration in exhaust gas from the burning of hydrocarbon fuel. Assuming that the observed carbon dioxide reduction is originated from the molecular decomposition, the energy needed for the endothermic reaction of this carbon dioxide reduction may stem primarily from the internal energy reduction in the exhaust gas in accordance of the first law of the thermodynamics. An oxygen increase due to the reduction in carbon dioxide in a discharge gas was observed in real time.

2010-01-01

277

Real-time strategy: Evolutionary game development  

British Library Electronic Table of Contents (United Kingdom)

Projects have become a way of getting things done, and have moved increasingly toward achieving qualitative goals. In this article on video game development, the opportunity is taken to relate some particular observations on creative projects and their management. The essential aspects of this approach are its incorporation of individual and group creativity into its foundation, a Lindblomian process of decision making, and a substitution of a time of regular introspection for milestones. Application depends upon the ability to have interim developments available for group examination and fixing a suitable time interval to make such assessments. The approach would seem applicable to a range of possibilities, including film making, script writing, architectural rendering, and equipment desi...

2006-01-01

278

Real-time neutron diffraction measurements of the kinetics of first-order phase transitions  

International Nuclear Information System (INIS)

The wide-angle neutron diffractometer recently installed at the HFIR has the capability of performing time-resolved or time-slicing measurements. One of the interesting problem areas the authors have explored using this time-slicing function of the diffractometer is the kinetics of structural changes occurring after a temperature jump across a value at which a first-order phase transition occurs. Two measurements of this sort have been carried out: the phase III to II transition in RbNO_3 and the transition between the alpha and beta phases in Sn.

1985-03-01

279

Real time neutron diffraction study on the intercalation of deuterobenzene into RbC/sub 24/  

Energy Technology Data Exchange (ETDEWEB)

The reaction of RbC/sub 24/ with C/sub 6/D/sub 6/ vapour was studied by neutron diffraction on a time scale of 5 min/spectrum. As for the reaction of KC/sub 24/, a second stage phase RbC/sub 24/(C/sub 6/D/sub 6/)sub(y) is initially formed and subsequently transformed into a first stage phase. Model calculations indicate that the benzene rings are canted against the graphite planes both in the first and in the second stage phase.

1983-11-01

280

RAPID DAMAGE ASSESSMENT FROM HIGH RESOLUTION IMAGERY  

Energy Technology Data Exchange (ETDEWEB)

Disaster impact modeling and analysis uses huge volumes of image data that are produced immediately following a natural or an anthropogenic disaster event. Rapid damage assessment is the key to time critical decision support in disaster management to better utilize available response resources and accelerate recovery and relief efforts. But exploiting huge volumes of high resolution image data for identifying damaged areas with robust consistency in near real time is a challenging task. In this paper, we present an automated image analysis technique to identify areas of structural damage from high resolution optical satellite data using features based on image content.

2008-07-01

281

Product identification in industrial batch fermentation using a variable forgetting factor  

British Library Electronic Table of Contents (United Kingdom)

For reliable operation and the optimization of production, industrial fermentation processes require appropriate tools for monitoring the process in real time. This work presents the structure and operation of a soft sensor for the on-line monitoring of biomass and product concentration during salinomycin and bacitracin fermentation in an industrial, 80-m^3 batch reactor; moreover it provides a tool for evaluation of batch production verified in industrial application. The process estimation algorithm consists of decoupled growth and product models, which ensures an unbiased convergence of the estimator and the robustness of the model. The production of secondary metabolites is described with a non-structured model upgraded with a variable forgetting factor that demonstrated a successful e...

2011-01-01

282

PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan  

International Nuclear Information System (INIS)

Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)

2007-06-01

283

On the eigenvalue control of electromechanical oscillations by adaptive power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the eigenvalue control strategy which utilizes an adaptive power system stabilizer for the decentralized control of damping and frequency of electromechanical oscillations in power systems. The control procedure includes the complete identification of the decoupled subsystem model in real-time from local measurements only and the assignment of its estimated electromechanical eigenvalue by the change of stabilizer parameters. The robustness and efficiency of the proposed adaptive controller to enhance overall system stability are illustrated in several examples, including the three-machine power system model.

1990-11-01

284

Neutron radiography at the University of Michigan's Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Real-time neutron radiography (RTNR) is rapidly becoming a valuable tool for nondestructive testing and basic research with a wide variety of applications. The Phoenix Memorial Laboratory (PML) at the University of Michigan has developed an RTNR facility and has been using this facility to study several phenomena of interest to researchers in many areas. These phenomena include imaging of the internal fluid flow in gas turbine engine nozzles and coking and debris deposition in several gas turbine nozzles. This paper presents a summary of the technique and facilities involved in these applications.

1990-06-10

285

Multiphase flow calculation software  

Energy Technology Data Exchange (ETDEWEB)

Multiphase flow calculation software and computer-readable media carrying computer executable instructions for calculating liquid and gas phase mass flow rates of high void fraction multiphase flows. The multiphase flow calculation software employs various given, or experimentally determined, parameters in conjunction with a plurality of pressure differentials of a multiphase flow, preferably supplied by a differential pressure flowmeter or the like, to determine liquid and gas phase mass flow rates of the high void fraction multiphase flows. Embodiments of the multiphase flow calculation software are suitable for use in a variety of applications, including real-time management and control of an object system.

2003-04-15

286

Micropulse Lidar (MPL) Handbook  

Energy Technology Data Exchange (ETDEWEB)

The micropulse lidar (MPL) is a ground-based optical remote sensing system designed primarily to determine the altitude of clouds overhead. The physical principle is the same as for radar. Pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is infered. Besides real-time detection of clouds, post-processing of the lidar return can also characterize the extent and properties of aerosol or other particle-laden regions.

2006-05-01

287

Machine condition monitoring using neural networks and the likelihood function  

Energy Technology Data Exchange (ETDEWEB)

A model-based technique incorporating neural networks has been developed for process monitoring. The technique is intended for processes where the uncertainty in the reference model is larger than desired but where process measurements providing additional information about the behavior of the system are available. This data is used to reduce the uncertainty of the model. The technique has been implemented in a real-time system for monitoring operational changes of mechanical equipment for use in predictive maintenance applications. Tests on a peristaltic pump were conducted and demonstrate the advantages of the proposed technique.

1997-09-01

288

Low cost, low power, high sensitivity, real time neutron detection microsystem  

International Nuclear Information System (INIS)

A Si array neutron detector is proposed based on commercial CCD and CMOS sensor technology coupled with a thin film neutron conversion coating. System sensitivity is estimated for a baseline device containing a single array and various schemes to increase detection probability by simple area scaling and stacking are discussed. Some possible use scenarios are discussed involving static and moving sources. Likely neutron source fluxes for weapons grade and commercial grade nuclear material are estimated along with expected intensities of cosmic background neutrons which would establish a noise floor to detection limits.

2002-10-10

289

Insight conference reports : proceedings of the smart meters forum  

Energy Technology Data Exchange (ETDEWEB)

This forum provided insights into Ontario's new smart meter program. Challenges related to implementing the smart meter program were reviewed, and various functional and operational considerations of the meters were considered. The implications and benefits of using real time metering systems were discussed along with issues related to energy conservation and demand management. Various communications technologies were considered in relation to smart metering program implementation. Issues related to pricing and pricing policies were also discussed. The conference featured 11 presentations, of which 2 have been catalogued separately for inclusion in this database. refs., tabs., figs.

2006-07-01

290

Industrial processing of complex fluids: Formulation and modeling  

Energy Technology Data Exchange (ETDEWEB)

The production of many important commercial materials involves the evolution of a complex fluid through a cooling phase into a hardened product. Textile fibers, high-strength fibers(KEVLAR, VECTRAN), plastics, chopped-fiber compounds, and fiber optical cable are such materials. Industry desires to replace experiments with on-line, real time models of these processes. Solutions to the problems are not just a matter of technology transfer, but require a fundamental description and simulation of the processes. Goals of the project are to develop models that can be used to optimize macroscopic properties of the solid product, to identify sources of undesirable defects, and to seek boundary-temperature and flow-and-material controls to optimize desired properties.

1997-08-01

291

Imaging Automation and Volume Tomographic Visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-11-14

292

INEEL BNCT research program. Annual report, January 1, 1996--December 31, 1996  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam measurement dosimetry, measurement of the Finnish research reactor epithermal neutron spectrum, BNCT accelerator technology; and chemistry: analysis of biological samples and preparation of {sup 10}B enriched decaborane.

1997-04-01

293

GPLS VME MODULE: A DIAGNOSTIC AND DISPLAY TOOL FOR NSLS MICRO SYSTEMS.  

Energy Technology Data Exchange (ETDEWEB)

The General Purpose Light Source VME module is an integral part of every front-end micro in the NSLS control system. The board incorporates features such as a video character generator, clock signals, time-of-day clock, a VME bus interrupter and general-purpose digital inputs and outputs. This module serves as a valuable diagnostic and real-time display tool for the micro development as well as for the final operational systems. This paper describes the functions provided by the board for the NSLS micro control monitor software.

1999-03-29

294

Florida State University - Explores! World Headquarters  

Science.gov (United States)

EXPLORES! (EXPloring and Learning the Operations and Resources of Environmental Satellites!) is an educational outreach program developed at Florida State University with the intention of introducing weather satellite receiving technology into the primary and secondary school classrooms. The website furnishes real time high resolution imagery and tropical updates. Visitors can find historical accounts of the civilian weather satellites launched by the United States. Educators can discover kindergarten through twelfth grade resources and curriculum. Users can learn how to become a part of the WXSAT-L community email list where weather satellite professionals, amateurs, and hobbyists converse about scientific, tracking, launching, and operations information.

295

Detection of mice lung cancer by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Thermal neutron beam from the TNRF of JRR-3M was utilized for detection of mice lung cancer in vivo. Both the static and real-time neutron imaging were tried. Very strong thermal neutron beam is necessary to detect lung cancers because small changes are hidden by the very large attenuation of thermal neutron beam by the hydrogens in the tissues. The detection was successfully performed. Especially, the Super Eye of Hamamatsu Photonics contributed very effectively. Bone marrows and cartilages were also shown clearly. If an efficient and compact neutron source will become available in future, this method will grow up as a powerful tool for biomedical application. (author).

1995-11-01

296

Design of self-tuning PID power system stabilizer for multimachine power systems  

Energy Technology Data Exchange (ETDEWEB)

A self-tuning PID (proportional-integral-derivative) power system stabilizer (PSS) is presented for improving the dynamic stability of a multimachine power system over a wide range of operating conditions. In order to maintain good damping characteristic when there is a drastic change in system operating condition, the gain settings are adapted in real time based on the continuously measured system inputs and outputs. The proposed self-tuning stabilizer has a decentralized structure and only local measurements within each generating units are required for the adaptation process. The effectiveness of the proposed stabilizer is demonstrated by an example.

1988-08-01

297

Design of a neutron radiography collimator system in a through beam port at the TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.

1996-12-31

298

Design and experimental investigation of a decentralized GA-optimized neuro-fuzzy power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

The aim of this research is the design and implementation of a decentralized power system stabilizer (PSS) capable of performing well for a wide range of variations in system parameters and/or loading conditions. The framework of the design is based on Fuzzy Logic Control (FLC). In particular, the neuro-fuzzy control rules are derived from training three classical PSSs; each is tuned using GA so as to perform optimally at one operating point. The effectiveness and robustness of the designed stabilizer, after implementing it to the laboratory model, is investigated. The results of real-time implementation prove that the proposed PSS offers a superior performance in comparison with the conventional stabilizer. (author)

2010-09-15

299

DEVELOPMENT OF A GEOGRAPHIC VISUALIZATION AND COMMUNICATIONS SYSTEMS (GVCS) FOR MONITORING REMOTE VEHICLES  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this project is to integrate a variety of geographic information systems capabilities and telecommunication technologies for potential use in geographic network and visualization applications. The specific technical goals of the project were to design, develop, and simulate the components of an audio/visual geographic communications system to aid future real-time monitoring, mapping and managing of transport vehicles. The system components of this feasibility study are collectively referred to as a Geographic Visualization and Communications System (GVCS). State-of-the-art techniques will be used and developed to allow both the vehicle operator and network manager to monitor the location and surrounding environment of a transport vehicle during shipment.

1998-03-30

300

Case study for the evaluation and selection of man-machine interface (MMI) software  

Energy Technology Data Exchange (ETDEWEB)

The authors evaluated three of the top man-machine interface (MMI) software systems. The main categories upon which they based their evaluation on were the following: operator interface; network and data distribution; input/output (I/O) interface; application development; alarms; real-time and historical trending; support, documentation, and training; processing tools (batch, recipe, logic); reports; custom interfacing; start-up/recovery; external database; and multimedia. They also present their MMI requirements and guidelines for the selection and evaluation of these MMI systems.

1996-06-01

301

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

302

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.

1984-10-01

303

Application of neutron radiography to visualization of multiphase flows  

Energy Technology Data Exchange (ETDEWEB)

Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).

1990-04-01

304

Application of neutron radiography to visualization of multiphase flows  

International Nuclear Information System (INIS)

Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).

1990-01-01

305

An application of the neutron television fluoroscopic system to neutron computed tomography  

International Nuclear Information System (INIS)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

306

A real time neutron diffraction study on the intercalation of deuterobenzene into RbC_2_4  

International Nuclear Information System (INIS)

The reaction of RbC_2_4 with C_6D_6 vapour was studied by neutron diffraction on a time scale of 5 min/spectrum. As for the reaction of KC_2_4, a second stage phase RbC_2_4(C_6D_6)sub(y) is initially formed and subsequently transformed into a first stage phase. Model calculations indicate that the benzene rings are canted against the graphite planes both in the first and in the second stage phase. (Auth.).

1983-01-01

307

A new type active personal dosemeter with a solid state detector  

International Nuclear Information System (INIS)

We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.

1988-04-01

308

Real-time neutron radiography; Radiografia com neutrons em tempo-real  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. ...

2000-07-01

309

Real-time neutron radiography  

International Nuclear Information System (INIS)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. The device composed ...

2000-01-01

310

Real-time monitoring of dosimetry and image quality during digital radiology examinations  

International Nuclear Information System (INIS)

Objective: To explore the feasibility of real-time monitoring exposure dose and image quality by using the data stored in the DICOM image archive of direct digital radiography system. Methods: Model TO. 16 was exposed, the current increased gradually from 0.5 to 125 mAs. The displayed number of model A( diameter 11.1 mm), D (diameter 4.0 mm) and J( diameter 0.7 mm) were recorded, and the detect factors (H_T) was also calculated. Images were sent to workstation before the end of DR examination. An automatic procedure was implemented to extract dose data and exposure parameters from the DICOM header file. Maximum, minimum and 3rd quartile values were preinstalled. Mean values exceeding the threshold trigger alarm signal to guide radiologist to explore the cause. Results: When the current of point A was less than 10 mAs and the current of point D and J were less than 16 mAs, the detect factor (H_T) increased with the rise of current. While point A located within ...

2009-12-01

311

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not affect the final results ...

1993-06-01

312

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (inner diameter; 4.08mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3 M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not affect the final ...

1994-07-01

313

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

International Nuclear Information System (INIS)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not affect the final results ...

1993-01-01

314

Analysis of reverse flow in inverted U-tubes of steam generator under natural circulation condition  

International Nuclear Information System (INIS)

In this paper, we report on the analysis of reverse flow in inverted U-tubes of a steam generator under natural circulation condition. The mechanism of reverse flow in inverted U-tubes of the steam generator with natural circulation is graphically analyzed by using the full-range characteristic curve of parallel U-tubes. The mathematical model and numerical calculation method for analyzing the reverse flow in inverted U-tubes of the steam generator with natural circulation have been developed. The reverse flow in an inverted U-tube steam generator of a simulated pressurized water reactor with natural circulation in analyzed. Through the calculation, the mass flow rates of normal and reverse flows in individual U-tubes are obtained. The predicted sharp drop of the fluid temperature in the inlet plenum of the steam generator due to reverse flow agrees very well ...

2008-12-01

315

Strand displacement synthesis capability of Moloney murine leukemia virus reverse transcriptase.  

UK PubMed Central (United Kingdom)

The accepted model of retroviral reverse transcription includes a circular DNA intermediate which requires strand displacement synthesis for linearization and creation of an integration-competent, long...Full Text Available

1994-08-01

316

Role-Reversal Exercise with Deaf Strong Hospital to Teach Communication Competency and Cultural Awareness  

UK PubMed Central (United Kingdom)

ObjectiveTo implement a role-reversal exercise to increase first-year pharmacy students' awareness of communication barriers in the health care setting, especially for deaf and hard-of-hearing...Full Text Available

2011-04-11

317

Reverse Engineering of Gene Regulatory Networks: A Comparative Study  

UK PubMed Central (United Kingdom)

Reverse engineering of gene regulatory networks has been an intensively studied topic in bioinformatics since it constitutes an intermediate step from explorative to causative gene expression...Full Text Available

2009-01-01

318

Phytochrome Control of Maize Coleoptile Section Elongation 1  

UK PubMed Central (United Kingdom)

A rapid loss of far red light (FR) reversibility of red-light (R) stimulated elongation of maize coleoptile sections was observed. Reversal was not possible when the interval between R and FR treatment...Full Text Available

1981-02-01

319

Localization of Reversion-Induced LIM Protein (RIL) in the Rat Central Nervous System  

UK PubMed Central (United Kingdom)

Reversion-induced LIM protein (RIL) is a member of the ALP (actinin-associated LIM protein) subfamily of the PDZ/LIM protein family. RIL serves as an adaptor protein and seems to regulate cytoskeletons....Full Text Available

2009-02-28

320

Energy extraction (a reversible process) from a Kerr source by tachyons  

International Nuclear Information System (INIS)

The author demonstrates through a specific example that it is possible to extract rotational energy from a Kerr source (in principle, of arbitrary size but not turned black) through a reversible process by suitably injecting tachyons. (Auth.).

321

Defective hepatitis B virus particles are generated by packaging and reverse transcription of spliced viral RNAs in vivo.  

UK PubMed Central (United Kingdom)

Generation of replicative defective viruses is frequently observed during viral infections. We now report that encapsidation and reverse transcription of spliced viral RNA is an additional mechanism...Full Text Available

1991-10-01

322

Conventional Linear versus Purse-string Skin Closure after Loop Ileostomy Reversal: Comparison of Wound Infection Rates and Operative Outcomes  

UK PubMed Central (United Kingdom)

PurposeWound infection after an ileostomy reversal is a common problem. To reduce wound-related complications, purse-string skin closure was introduced as an alternative to conventional...Full Text Available

2011-04-01

323

A plausible model for reversal of neoplastic transformations in plants based on multiple steady states.  

UK PubMed Central (United Kingdom)

We offer a plausible interpretation of some experiments on the reversal of neoplastic transformations in plants. We suggest that normal cells and tumorous cells represent multiple stable-steady states...Full Text Available

1991-12-01

324

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

326

Cartridge Cases  

Science.gov (United States)

... reverse aeb 9 nescesmsy amI identify by block number) Provides procedures for evaluating metal, consumable, and combustible cartridge cases. ...

1980-10-21

327

MOS device chemical response reversal with temperature  

British Library Electronic Table of Contents (United Kingdom)

Biased above threshold (VT), pulsed photocurrent (u) measurements on windowed silicon Pd gate MOS capacitors are shifted (DV) negatively by H2/N2, whereas Au gates shift positively under NO2/air. Below VT, the shifts are reversed by adjustments of interface state population. Minor temperature increases may coax the device from inversion to depletion, inducing sign reversal of the chemical response.

2010-01-01

328

Dynamic Deformation and Recovery Response of Red Blood Cells to a Cyclically Reversing Shear Flow: Effects of Frequency of Cyclically Reversing Shear Flow and Shear Stress Level  

UK PubMed Central (United Kingdom)

Dynamic deformation and recovery responses of red blood cells (RBCs) to a cyclically reversing shear flow generated in a 30-μm clearance, with the peak shear stress of 53, 108,...Full Text Available

2006-09-01

329

Investigation into #beta##reversible##omega#-transformation in pseudo -#beta# -titanium VT30 alloy, doped with hydrogen  

International Nuclear Information System (INIS)

To study #beta# #reversible# #omega#-transformation in pseudo-#beta#-titanium alloy VT30, doped by hydrogen, methods of X-ray diffraction and thermodifferential analyses are used. It is established that in the process of heating of the hardened alloy from 0.004-0.1% H first formation and then dissolution of #omega# phase take place. An increase in hydrogen content to 0.1% decreases thermal effect of the processes and does not affect the temperature of #beta# #reversible# #omega#-transformation. Introduction of hydrogen in the concentration of 0.2% and higher suppresses completely #beta# #reversible# #omega# - transformation. A decrease in heating rate displaces #beta# #reversible# #omega#-transformation to lower temperatures.

330

Reverse time migration for ground penetrating radar using finite difference time domain method; Jikan ryoiki yugenn sabunho ni yoru chichu reda no ribasu taimu maigureshon  

Energy Technology Data Exchange (ETDEWEB)

The reversion time migration, as one of reflection seismic prospecting migration, reverse propagates a wave equation by reverse promoting the differential time, and conducts the migration. The method has such merits as no limit to the inclined angle of a reflection, correspondence to a complex topography etc. And, there is a finite difference time domain (FDTD) that uses the Maxwell equation as it is and makes a difference approximation in the methods differentiating and resolving electro-magnetic fields. It is also possible to apply the reverse time migration onto it. In this speech, using an explosive reflection face, a slope 2 layer structure and models of its reflection points are synthesized by a ground penetrating radar using the FDTD, and reverse time migration is conducted. As a result, it is clarified that the reverse time migration is valid for the ...

1999-02-01

331

Water resources management in Asia. Volume 1. Main report. World Bank technical paper  

Energy Technology Data Exchange (ETDEWEB)

The report, Water Resources Management in Asia, has three objectives: To describe the situation confronting the region's borrowers, devise approaches to better deal with the present and future water related problems that affect their well-being and equip the staff to actively participate in the regional and Bank-wide efforts to strengthen the sector. The principal water resources problems and issues have been placed in four categories: Institutional, long-term management and planning, real-time management and operations, and financial. Such an arrangement provides a perspective for examining concerns across all economic sectors and allows formulation of solutions that will constitute a truly comprehensive, balanced approach to the critical situation encountered in managing these resources. A summary of past Bank activities has confirmed that an historic approach is not adequate to address the pressing problems of today and the future.

1993-01-01

332

Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography  

International Nuclear Information System (INIS)

The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.

1999-11-03

333

Vapor fraction measurements in a steam-water duct at atmospheric pressure using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography has been used to study the dynamic behavior of two-phase flow and measure vapor fractions in a steam-water duct at atmospheric pressure. This unique experimental technique offers one the opportunity to observe and record on videotape now Patterns and transient behavior of two-phase flow inside opaque containers without perturbing the environment. The neutron radiographic technique is non-intrusive and requires no special transparent window region. Data are recorded simultaneously over a large area of interest. Image processing of the video data can be employed to measure bubble velocities and time-averaged and Instantaneous vapor fractions.

1994-11-11

334

Two-level atom at finite temperature  

CERN Document Server

Properties of a two-level atom coupled to the quantized electromagnetic field at finite temperature are studied. The analysis is based on a new method (inspired by QED) of describing qubits, developed previously by us at zero temperature (Phys. Rev. A 76, 062106 (2007)). In this paper, we make a generalization to finite temperature by introducing the Matsubara formalism and the temperature propagators. We analyze the spectral properties of different types of propagators and we derive a direct connection between the temperature propagators and the real time propagators. To show the effectiveness of this method, we calculate the temperature dependence of the polarizability of a two-level atom in the lowest order of perturbation theory and we predict an unexpected sharpness in the resonance behavior. The whole discussion is carried out without making the rotating wave approximation.

2009-01-01

335

Transient suppression of MLH1 allows effective single-nucleotide substitution by single-stranded DNA oligonucleotides  

British Library Electronic Table of Contents (United Kingdom)

Short synthetic single-stranded oligodeoxyribonucleotides (ssODNs) can be used to introduce subtle modifications into the genome of mouse embryonic stem cells (ESCs). We have previously shown that effective application of ssODN-mediated gene targeting in ESC requires (transient) suppression of DNA mismatch repair (MMR). However, whereas transient down-regulation of the mismatch recognition protein MSH2 allowed substitution of 3 or 4 nucleotides, 1 or 2 nucleotide substitutions were still suppressed. We now demonstrate that single- or dinucleotide substitution can effectively be achieved by transient down-regulation of the downstream MMR protein MLH1. By exploiting highly specific real-time PCR, we demonstrate the feasibility of substituting a single basepair in a non-selectable gene. Howev...

2011-01-01

336

Time-resolved neutron diffraction study of the superconducting phase formation process in the Bi(PB)-Sr-Ca-Cu-O system  

Energy Technology Data Exchange (ETDEWEB)

The results of real-time neutron diffraction measurements during the superconducting phase formation process in the Bi(Pb)-Sr-Ca-Cu-O system are reported. A Sr-Ca-Cu-O type precursor, with the same stoichiometry as the 2223 phase, was used as starting material, and the temperature range favorable to the formation of the 2223 phase was investigated. The diffraction patterns were processed by a multiphase Rietveld refinement. The formation and decomposition of the 2201 and 2212 phases were directly observed. Experimental evidence on the existence of a partially melted phase in the range 855-860[degrees]C, involved in the formation of the 2223 phase, is discussed. 14 refs., 9 figs., 1 tab.

1993-08-01

337

Time-resolved neutron diffraction study of the superconducting phase formation process in the Bi(PB)-Sr-Ca-Cu-O system  

International Nuclear Information System (INIS)

The results of real-time neutron diffraction measurements during the superconducting phase formation process in the Bi(Pb)-Sr-Ca-Cu-O system are reported. A Sr-Ca-Cu-O type precursor, with the same stoichiometry as the 2223 phase, was used as starting material, and the temperature range favorable to the formation of the 2223 phase was investigated. The diffraction patterns were processed by a multiphase Rietveld refinement. The formation and decomposition of the 2201 and 2212 phases were directly observed. Experimental evidence on the existence of a partially melted phase in the range 855-860 degrees C, involved in the formation of the 2223 phase, is discussed. 14 refs., 9 figs., 1 tab.

338

The silent gallstone: Follow-up of 33 cases.  

Science.gov (United States)

This study reports the outcome of real-time ultrasonographic screening tests of a healthy population. The study group consisted of 33 female teachers who were found to have asymptomatic gallstone disease. All cases were followed up to determine the incidence of biliary colic or complications. After a 38-month period of follow-up, seven subjects (21.2%) developed either biliary colic or complication. Study results revealed that the 38-month cumulative probability of the development of biliary colic or complication was 36%. Data shown that development of biliary colic or complications was positively associated with obesity, but no assocition was found with age, number of activities, or duration of contraceptive pill-taking. Having such a high percentage of subjects who developed biliary colic or complications within a relatively short period of time suggests that the silent gallstone is not innocent. PMID:17372404

1996-03-01

339

The expression pattern of scygonadin during the ontogenesis of Scylla paramamosain predicting its potential role in reproductive immunity  

British Library Electronic Table of Contents (United Kingdom)

The antimicrobial peptide scygonadin (Scy) was first isolated from the gonad of Scylla serrata and its gene is predominantly expressed in the ejaculatory duct of adult males. Thus, its function was predicted to be associated with reproductive immunity, but this is still unclear and needs further investigation. In our study, the expression pattern of Scy at different developmental stages of both male and female S. paramamosain was investigated, so that the potential function of this peptide could be examined. Using real-time quantitative PCR, Scy mRNA transcripts were demonstrated obviously in the vulnerable embryos and larvae-zoea I but very weakly detected in the larvae-zoea III, megalops and juveniles. The gene expression pattern showed a decreasing trend during the early developmental s...

2011-01-01

340

The Multipoles Factory An Element of the LHC Control  

CERN Document Server

The measurements performed at CERN on prototypes and first pre-series main dipole magnets confirm the need of an active control of the Large Hadron Collider to compensate the dynamic field changes during the proton beam injection and acceleration. This control requires in turn an accurate forecast of the magnetic field in the accelerator. We plan to predict the field on the basis of two elements: theoretical field models tailored through the accumulated knowledge of the main magnets during series tests, and an on-line measurement system running on few reference magnets tracking the LHC current cycle. Data coming from this "Multipoles Factory" will result from the fusion of the two sources. Based on this system we foresee to deliver calibration information for pre-defined accelerator cycles as well as real time information for the active control. In this paper we report the conceptual design of the system, and we discuss the features and ...

2002-01-01

341

Targeted drug delivery under MRI guidance  

British Library Electronic Table of Contents (United Kingdom)

The main goal of local drug delivery is to increase the concentration of a specific therapeutic agent in a target tissue with minimal nontarget distribution. Compared to systemic therapy, local drug delivery provides a high level of therapeutic efficacy with minimal systemic effects. The current primary imaging modality for drug delivery has been x-ray angiography, but it has major limitations including anatomical ambiguity and inability to visualize the targeted tissues. Due to these inherent problems, MR guidance has been explored as an alternative imaging modality for guiding and monitoring of drug therapy. Recently, interventional MR (XMR) systems have been implemented that have both dual x-ray and MRI capabilities in a single suite and allow for real-time interventional procedures to ...

2008-01-01

342

Study of a loop heat pipe using neutron radiography.  

Science.gov (United States)

An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design. PMID:15246420

2004-10-01

343

Study of a loop heat pipe using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.

2004-10-01

344

Study of a Loop Heat Pipe Using Neutron Radiography  

Energy Technology Data Exchange (ETDEWEB)

An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, has been identified with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.

2001-08-01

345

Stop-and-go kinetics in amyloid fibrillation  

CERN Document Server

Many human diseases are associated with protein aggregation and fibrillation. We present experiments on in vitro glucagon fibrillation using total internal reflection fluorescence microscopy, providing real-time measurements of single-fibril growth. We find that amyloid fibrils grow in an intermittent fashion, with periods of growth followed by long pauses. The observed exponential distributions of stop and growth times support a Markovian model, in which fibrils shift between the two states with specific rates. Remarkably, the probability of being in the growing (stopping) state is very close to 1/4 (3/4) in all experiments, even if the rates vary considerably. This finding suggests the presence of 4 independent conformations of the fibril tip; we discuss this possibility in terms of the existing structural knowledge.

2009-01-01

346

Stent placement under real-time MR control: first experience in an animal model; Stentplazierung unter Echtzeit-MR-Kontrolle: erste tierexperimentalle Erfahrungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored by real-time MR were ...

1998-12-01

347

Software development for a switch-based data acquisition system  

Energy Technology Data Exchange (ETDEWEB)

We report on the software aspects of the development of a switch-based data acquisition system at Fermilab. This paper describes how, with the goal of providing an integrated systems engineering'' environment, several powerful software tools were put in place to facilitate extensive exploration of all aspects of the design. These tools include a simulation package, graphics package and an Expert System shell which have been integrated to provide an environment which encourages the close interaction of hardware and software engineers. This paper includes a description of the simulation, user interface, embedded software, remote procedure calls, and diagnostic software which together have enabled us to provide real-time control and monitoring of a working prototype switch-based data acquisition (DAQ) system.

1991-12-01

348

Software development for a switch-based data acquisition system  

Energy Technology Data Exchange (ETDEWEB)

We report on the software aspects of the development of a switch-based data acquisition system at Fermilab. This paper describes how, with the goal of providing an ``integrated systems engineering`` environment, several powerful software tools were put in place to facilitate extensive exploration of all aspects of the design. These tools include a simulation package, graphics package and an Expert System shell which have been integrated to provide an environment which encourages the close interaction of hardware and software engineers. This paper includes a description of the simulation, user interface, embedded software, remote procedure calls, and diagnostic software which together have enabled us to provide real-time control and monitoring of a working prototype switch-based data acquisition (DAQ) system.

1991-12-01

349

Simulation of the New York Power Pool for dispatcher training  

Science.gov (United States)

This paper describes the simulation of the operating environment of the New York Power Pool (NYPP) within the Dispatcher Training Simulator facility at the New York State Electric and Gas Corporation (NYSEG). The NYSEG control center uses real-time data received from the NYPP control center to control its internal generation. In addition, the NYSEG dispatchers work very closely with the NYPP dispatchers. The exact emulation of the Generation Control functions of the NYPP EMS, and the associated data exchange with the NYSEG ECS, contribute greatly to the high degree of realism achieved in the NYSEG DTS facility. The accuracy of the power system simulation in the DTS has been validated against actual power system disturbances recorded at NYSEG.

1994-11-01

350

Security features of a nuclear material accounting system  

Energy Technology Data Exchange (ETDEWEB)

The Los Alamos Nuclear Material Accounting and Safeguards System (MASS) is a near-real-time accountability system for bulk materials, discrete items, and material undergoing dynamic processing. MASS has evolved from an eighty-column card based process control system to a very sophisticated computer system. The security of the MASS computer system is provide through various access controls. There are two kinds of access control to be addressed. They are physical access control to the hardware which make up the system, and access control to the software. There are many features which provide a measure of security to the hardware that will be discussed. Access to the software is controlled by a security password. Access to various transaction activities in the system is controlled through the level of MASS user privilege. Details of MASS user privilege will be discussed.

1988-01-01

351

Scaffolding collaborative technical writing with procedural facilitation and synchronous discussion  

British Library Electronic Table of Contents (United Kingdom)

With the advent of computer technology, researchers and instructors are attempting to devise computer support for effective collaborative technical writing. In this study, a computer-supported environment for collaborative technical writing was developed. This system (Process-Writing Wizard) provides process-oriented scaffolds and a synchronous online chat room to facilitate real-time collaborative writing practice. It allows multiple students to work synchronously on collaborative writing tasks via the Internet. It also helps develop collaborative writing strategies, such as creating team agendas, brainstorming, creating team outlines, and generating team articles. An experiment was conducted to examine the effect of the system on EFL (English as a Foreign Language) students? collaborativ...

2011-01-01

352

SASE: Complex Event Processing over Streams  

CERN Document Server

RFID technology is gaining adoption on an increasing scale for tracking and monitoring purposes. Wide deployments of RFID devices will soon generate an unprecedented volume of data. Emerging applications require the RFID data to be filtered and correlated for complex pattern detection and transformed to events that provide meaningful, actionable information to end applications. In this work, we design and develop SASE, a com-plex event processing system that performs such data-information transformation over real-time streams. We design a complex event language for specifying application logic for such transformation, devise new query processing techniques to effi-ciently implement the language, and develop a comprehensive system that collects, cleans, and processes RFID data for deliv-ery of relevant, timely information as well as storing necessary data for future querying. We demonstrate an initial prototype of SASE through a real-world retail management ...

2006-01-01

353

Robotic drilling system for titanium structures  

British Library Electronic Table of Contents (United Kingdom)

Manual drilling in titanium structures is a tedious and labor-intensive work. To reduce man-hour requirements while concurrently improving hole quality, we developed a robotic drilling system for this application. The lean system contains the product holding fixture, the industrial robot, the end effector, the control and sensor system, and the offline programming. The system functions include locating workpiece with a calibration stick or the vision system, weld mark inspection, one-sided clamping, drilling and reaming hole in material stack combinations of titanium and aluminum, and real-time thrust force feedback. The positional accuracy and the repeatability of the system have successfully been placed within the specification?s 0.3?mm tolerance and 0.2?mm tolerance, respectively. The d...

2011-01-01

354

Research on pitting corrosion of steam generator heat transfer tubes based on acoustic emission  

International Nuclear Information System (INIS)

Corrosion of steam generator heat transfer tubes (SGHTT) is one of the important problems which affect safety operation of nuclear power plants (NPP), and the hazard of pitting corrosion of heat transfer tubes is the most serious. With an acoustic emission device, the signals during a corrosion test on SGHTT were collected and analyzed, and the corrosion points in the tubes were located accurately. The results show that pitting corrosion of heat transfer tubes has passed through three periods in its development: expansion phase, stationary phase and rapid developing phase. The corrosion damage of HTT can be found earlier with acoustic emission than any other non-destructive testing methods. Acoustic emission can be used for on-line and real-time monitoring of the safety and operation of the steam generator and has therefore a great significance. (orig.)

2010-09-01

355

Reconstructions of archaeological contexts in OpenGl environments; Intelligenza artificiale per i beni culturali e le biblioteche digitali. Atti del Workshop  

Energy Technology Data Exchange (ETDEWEB)

DVR project concerns the creation of a virtual reality OpenGL system for desktop applications in archaeology. The main goal is the creation of a 3D information system using the real time interaction of OpenGL environments. The first case study implemented is the Vettii House, one of the most important and outstanding monuments in Pompei. The virtual reconstruction of these architectural models is based on very detailed photogrammetric surveys and it is connected with information layers and archaeometric data-bases regarding the state of conservation of walls, structures and any type of materials of the monument. A full 3D interface characterizes the system, comprising a high resolution texturing with detailed volumetric and geometric data. Finally, for the future, the project plans to fit the system for scientific and end users through the installation of stations on site.

2001-07-01

356

Real-time neutron scattering investigations of biological signal transduction dynamics  

Energy Technology Data Exchange (ETDEWEB)

During their catalytic cycle, proteins involved in biological signal transduction undergo unexpectedly large conformational changes, which are at the core of their biological functioning. Until now it has been extremely difficult to obtain experimental insight into the nature of these conformational changes. Mathematical modeling and time-resolved X-ray crystallography have resulted in probable routes along which these conformational changes may take place, but so far this fundamental biological phenomenon has hardly been tackled experimentally. Here, we report on an attempt to observe structural changes in Photoactive Yellow Protein with time-resolved small-angle neutron scattering using diffractometer D22 at the high-flux reactor of the Institut Laue-Langevin, Grenoble, France.

2005-07-01

357

Real-time neutron scattering investigations of biological signal transduction dynamics  

International Nuclear Information System (INIS)

During their catalytic cycle, proteins involved in biological signal transduction undergo unexpectedly large conformational changes, which are at the core of their biological functioning. Until now it has been extremely difficult to obtain experimental insight into the nature of these conformational changes. Mathematical modeling and time-resolved X-ray crystallography have resulted in probable routes along which these conformational changes may take place, but so far this fundamental biological phenomenon has hardly been tackled experimentally. Here, we report on an attempt to observe structural changes in Photoactive Yellow Protein with time-resolved small-angle neutron scattering using diffractometer D22 at the high-flux reactor of the Institut Laue-Langevin, Grenoble, France

2005-04-11

358

Real-time neutron diffraction study of crystallization kinetics in amorphous Fe_7_8B_1_3Si_9 alloy  

International Nuclear Information System (INIS)

The transformation from the as-quenched amorphous to the crystalline state in Fe_7_8B_1_3Si_9 alloy has been investigated using a new-type neutron diffractometer. The time resolved diffraction patterns clearly show that this alloy crystallizes into FeSi alloy and Fe_2B in that order. The time evolution of these crystalline phases can be analyzed by the Kolmogorov-Johnson-Mehl-Avrami equation with the exponent of about 2.5 over a wide temperature range. This suggests that the crystallization occurs by the diffusion-controlled growth with a constant nucleation rate. The scaling behavior in the crystallization kinetics is also discussed. (author).

1987-01-01

359

Real-time neutron diffraction study of crystallization kinetics in amorphous Fe/sub 78/B/sub 13/Si/sub 9/ alloy  

Energy Technology Data Exchange (ETDEWEB)

The transformation from the as-quenched amorphous to the crystalline state in Fe/sub 78/B/sub 13/Si/sub 9/ alloy has been investigated using a new-type neutron diffractometer. The time resolved diffraction patterns clearly show that this alloy crystallizes into FeSi alloy and Fe/sub 2/B in that order. The time evolution of these crystalline phases can be analyzed by the Kolmogorov-Johnson-Mehl-Avrami equation with the exponent of about 2.5 over a wide temperature range. This suggests that the crystallization occurs by the diffusion-controlled growth with a constant nucleation rate. The scaling behavior in the crystallization kinetics is also discussed.

1987-09-01

360

Reactions of the inner surface of carbon nanotubes and nanoprotrusion processes imaged at the atomic scale  

British Library Electronic Table of Contents (United Kingdom)

Although the outer surface of single-walled carbon nanotubes (atomically thin cylinders of carbon) can be involved in a wide range of chemical reactions, it is generally thought that the interior surface of nanotubes is unreactive. In this study, we show that in the presence of catalytically active atoms of rhenium inserted into nanotubes, the nanotube sidewall can be engaged in chemical reactions from the inside. Aberration-corrected high-resolution transmission electron microscopy operated at 80?keV allows visualization of the formation of nanometre-sized hollow protrusions on the nanotube sidewall at the atomic level in real time at ambient temperature. Our direct observations and theoretical modelling demonstrate that the nanoprotrusions are formed in three stages: (i) metal-assisted d...

2011-01-01

361

Radon measurements at the FEMP  

Energy Technology Data Exchange (ETDEWEB)

Environmental radon monitoring activities at the DOE Fernald Environmental Management Project (FEMP) have been conducted extensively since the early 1980`s. Monitoring has been conducted at ambient concentration levels (< 1 pCi/L Rn-222), inside buildings, and at significantly elevated levels (hundreds of thousands pCi/L Rn-222) within the K-65 silo that store concentrated radium bearing wastes. The purpose of this paper/presentation is to present and discuss some of the difficulties encountered/solutions (e.g. reliability, detection limits, affects of environmental factors, data transfer, etc.) that have been discovered while taking measurements using both alpha track-etch passive integrating detectors and alpha scintillation real-time detectors. A short summary and conclusion section is provided following each topic presented.

1993-08-01

362

RECOVERY ACT: DYNAMIC ENERGY CONSUMPTION MANAGEMENT OF ROUTING TELECOM AND DATA CENTERS THROUGH REAL-TIME OPTIMAL CONTROL (RTOC): Final Scientific/Technical Report  

Science.gov (United States)

This final scientific report documents the Industrial Technology Program (ITP) Stage 2 Concept Development effort on Data Center Energy Reduction and Management Through Real-Time Optimal Control (RTOC). Society is becoming increasingly dependent on information technology systems, driving exponential growth in demand for data center processing and an insatiable appetite for energy. David Raths noted, 'A 50,000-square-foot data center uses approximately 4 megawatts of power, or the equivalent of 57 barrels of oil a day1.' The problem has become so severe that in some cases, users are giving up raw performance for a better balance between performance and energy efficiency. Historically, power systems for data centers were crudely sized to meet maximum demand. Since many servers operate at 60%-90% of maximum power while only utilizing an average of 5% to 15% of their capability, there are huge inefficiencies in the consumption and delivery of power in ...

2011-06-30

363

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

364

Photoelectron resonance capture ionization mass spectrometry: a soft ionization source for mass spectrometry of particle-phase organic compounds.  

Science.gov (United States)

Photoelectron resonance capture ionization (PERCI) is a soft and sensitive ionization method, based on the attachment of low-energy (<1 eV) photoelectrons to organic analyte molecules. PERCI has been developed in our laboratory for the real-time analysis of organic particles by mass spectrometry, and is employed here to monitor the heterogeneous reaction of ozone with oleic acid. Simplified identification of the reaction products is possible as a result of the soft nature of PERCI, giving predominantly the [M--H](-) ions. The major particle-phase products are identified as: 1-nonanal, nonanoic acid, 9-oxononanoic acid, and azelaic acid, consistent with proposed mechanisms. New insight into this well-studied heterogeneous reaction is gained as additional minor particle-phase products, consistent with the Criegee mechanism, are readily detected. PMID:15468105

2004-01-01

365

Operating experience with a new accelerator control system based upon microprocessors  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design and operating experience with a high performance control system tailored to the requirements of the SuperHILAC accelerator. A large number (20) of the latest 16-bit microcomputer boards are used in a parallel-distributed manner to get a high system bandwidth. Because of the high bandwidth, software costs and complexity are significantly reduced. The system by its very nature and design is easily upgraded and repaired. Dynamically assigned and labeled knobs, together with touch-panels, allow a flexible and efficient operator interface. An X-Y vector graphics system provides for display and labeling of real-time signals as well as general plotting functions. This control system allows attachment of a powerful auxiliary computer for scientific processing with access to accelerator parameters.

1981-03-01

366

OTVE turbopump condition monitoring, task E. 5. Final report, October 1988-September 1989  

Energy Technology Data Exchange (ETDEWEB)

Recent work has been carried out on development of isotope wear analysis and optical and eddy current technologies to provide bearing wear measurements and real time monitoring of shaft speed, shaft axial displacement and shaft orbit of the Orbit Transfer Vehicle hydrostatic bearing tester. Results show shaft axial displacement can be optically measured (at the same time as shaft orbital motion and speed) to within 0.3 mils by two fiberoptic deflectometers. Evaluation of eddy current probes showed that, in addition to measuring shaft orbital motion, they can be used to measure shaft speed without having to machine grooves on the shaft surface as is the usual practice for turbomachinery. The interim results of this condition monitoring effort are presented.

1989-08-01

367

Novel, convenient, and nonpersistent radiotracer for environmental and energy applications  

Energy Technology Data Exchange (ETDEWEB)

A newly-available radioisotopic system, /sup 172/Hf-/sup 172/Lu, has excellent potential for tracer applications in which nuclear data acquisition must be accomplished in real time. The 6.7-day half-life of /sup 172/Lu is sufficient for a large fraction of tracer experiments, and should allow the direct incorporation of /sup 172/Lu into tests that have traditionally utilized much longer-lived radionuclides. Since /sup 172/Lu is the daughter component of a radioisotope generator, however, its effective shelf-life is determined by the half-life of its 1.9-year /sup 172/Hf parent. Consequently, the frequency of isotope procurement need not be any more extensive than investigators would normally be accustomed to. Discussion relevant to isotope production, generator operation, and nuclide acquisition is presented in this paper.

1984-03-12

368

New thermal neutron imaging facility at the University of Texas reactor  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.

1999-09-01

369

New monitoring system for microbiological control effectiveness on pitting corrosion of carbon steel  

Energy Technology Data Exchange (ETDEWEB)

A new on-line monitoring system has been developed for pitting corrosion monitoring of carbon steel tubes in cooling water systems. This monitoring system was found to be quite sensitive to the microbiological activity relating to pitting corrosion on a real-time basis. The value of galvanic current indicates the performance level of pitting corrosion inhibition even in biocide application. In addition, the changes in the galvanic current provide indicative information about the effectiveness in microbiological control program, even when the pressure drop measurement indicates no biofilm formation. It can be also useful in detecting a microbiological control upset. In this paper, an introduction of the new monitoring system as a microbiological control effectiveness monitor and the field test results are discussed.

1997-12-01

370

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

371

Neural integrated control for a free-floating space robot with suddenly changing parameters  

British Library Electronic Table of Contents (United Kingdom)

Because the state of a free-floating space robot model is uncertain and sudden changes in the model parameters might undermine the stability of the system, this paper proposes a control strategy based on a variable structure neural integrated controller. This scheme does not need a precise space robot model, making use of the radial basis function neural network ability approach to learn about an uncertain model. The network weights are adjusted online in real-time. During the early period of the control phase and parameter changes, the variable structure controller compensates for the uncertain model which the neural network could not learn well. It also creates global asymptotic stability for the whole closed-loop system. Simulation results show that the controller can handle bad changea...

2011-01-01

372

Netrawalm: Network Based Resource Aware Application Layer Multicast for Multiparty Video Conference  

CERN Document Server

IP Multicast is one of the most absolute method for large bandwidth Internet applications such as video conference, IPTV, E-Learning and Telemedicine etc., But due to security and management reason IP Multicast is not enabled in Internet backbone routers. To achieve these challenges, lot of Application Layer Multicast (ALM) has been proposed. All the existing protocols such as NICE, ZIGZAG and OMNI are trying to reduce average delay by forming a Multicast tree. But still that problem has not been addressed fully. We are proposing a new protocol called NetRawALM, which will address the average delay, Reliability between nodes, Scalability of conference, Heterogeneity and resilient data distribution for real time multimedia applications by constructing the Network based Resource aware Multicast tree algorithm. This is very dynamic and decentralised. The proposed architecture is a LAN aware; it is used to reduce Internet Traffic.

2011-01-01

373

Modeling dispersion and deposition of smoke generated from chemical fires  

British Library Electronic Table of Contents (United Kingdom)

Abstract Smoke is a mixture of toxic gases and suspended particulate matter of solids and liquids that evolves from a fire of flammable materials. This article presents real-time consequence modeling to track the concentration of individual species in smoke as well as its soot deposition. In the modeling process presented, the burning rate or vapor mass is fed into a combustion model in which the combustion of products has been identified and quantified along with the temperature of the fire. The output of the combustion model is the smoke that will be dispersed into the ambient. The fire geometry, which depends on the type of fire (e.g., pool or flare), is identified. A dispersion model with the capability of determining particulate deposition is then used for tracking the smoke plume. Th...

2011-01-01

374

Involvement of a putative response regulator Brrg-1 in the regulation of sporulation, sensitivity to fungicides, and osmotic stress in Botrytis cinerea  

British Library Electronic Table of Contents (United Kingdom)

The response regulator protein is a core element of two-component signaling pathway. In this study, we investigated functions of BRRG-1 of Botrytis cinerea, a gene that encodes a putative response regulator protein, which is homologous to Rrg-1 in Neurospora crassa. The BRRG-1 gene deletion mutant ?Brrg1-62 was unable to produce conidia. The mutant showed increased sensitivity to osmotic stress mediated by NaCl and KCl, and to oxidative stress generated by H2O2. Additionally, the mutant was more sensitive to the fungicides iprodione, fludioxonil, and triadimefon than the parental strain. Western-blot analysis showed that the Bos-2 protein, the putative downstream component of Brrg-1, was not phosphorylated in the ?Brrg1-62. Real-time polymerase chain reaction assays showed that expression ...

2011-01-01

375

Integrated evolutionary neural network approach with distributed computing for congestion management  

British Library Electronic Table of Contents (United Kingdom)

Electric supply industry is facing deregulation all over the world. Under deregulated power supply scenario, power transmission congestion has become more intensified and recurrent, as compared to conventional regulated power system. Congestion may lead to violation of voltage or transmission capacity limits, thus threatens the power system security and reliability. Also the growing congestion may lead to unanticipated divergent electricity pricing. Owing to these facts congestion management has become a crucial issue in the deregulated power system scenario. Fast and precise prediction of nodal congestion prices in real time deregulated/spot power market may enable market participants and system operators to keep pace with the congestion by taking preventive measures like transaction resc...

2010-01-01

376

Improving functional esophageal surgery with a ?smart? bougie: endoflip  

British Library Electronic Table of Contents (United Kingdom)

Background An emerging imaging tool, the functional lumen imaging probe (Endoflip; Crospon Ltd, Galway, Ireland), provides a real-time measurement of esophagogastric junction (EGJ) capacity and diameter, which would be of particular interest in functional esophageal surgery such as Heller myotomy and antireflux procedures. This study aimed to demonstrate the intraoperative use of endoflip in the treatment of achalasia and gastroesophageal reflux disease (GERD). Methods In the first case, Heller myotomy was performed under endopflip guidance, for persistent dysphagia after failed endoscopic dilatation. In the second case, the endoflip was used to calibrate a Nissen fundoplication. With the patient under general anesthesia, the endoflip catheter was inserted orally and positioned to straddle...

2011-01-01

377

Imaging automation and volume tomographic visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced a good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-07-01

378

Hypomethylation and induction of retinoic acid receptor beta 2 by concurrent action of adenosine analogues and natural compounds in breast cancer cells  

British Library Electronic Table of Contents (United Kingdom)

DNA methylation is considered as a potential cause of aberrations in regulation of gene expression during carcinogenesis. Therefore, changes in DNA methylation patterns may be targets for chemoprevention. In the present study, we investigated effects of all-trans retinoic acid (ATRA), vitamin D3, and resveratrol alone and in combination with adenosine analogues: 2-chloro-2'-deoxyadenosine (2CdA) and 9-beta-d-arabinosyl-2-fluoroadenine (F-ara-A), on methylation and expression of retinoic acid receptor beta 2 (RARbeta2) in MCF-7 and MDA-MB-231 breast cancer cell lines. Alterations in methylation and expression levels after treatment of cells with the tested compounds were evaluated by methylation-sensitive restriction analysis (MSRA) and real-time PCR, respectively. RARbeta2 promoter in the ...

2010-01-01

379

Growing RBFNN-based soft computing approach for congestion management  

British Library Electronic Table of Contents (United Kingdom)

In the emerging restructured power system, the congestion management (CM) has become extremely important in order to ensure the security and reliability of the system. In addition to this, lack of CM can impose a hindrance in electricity trading. This paper presents a novel, growing radial basis function neural network (GRBFNN)-based approach for CM. For achieving CM, Nodal congestion price (NCP) forecasting is performed in real time competitive power market. NCP forecasting is an effective way of price-based preventive CM as it directly indicates the presence as well as the severity of the congestion in the system. In present paper, GRBFNN has been developed for NCP forecasting dividing the whole power system into various congestion zones. An unsupervised learning vector quantization (VQ)...

2009-01-01

380

Furnace for rapid change of temperature for neutron diffraction  

International Nuclear Information System (INIS)

A new furnace for neutron diffraction experiments is capable of heating and cooling a sample very rapidly. The rapid heating is done by two circular infrared lamps placed over and under a sample, whose radiation is roughly focused on the sample by a reflector. The rapid cooling is done by high-pressure gas blows against the sample from two circular nozzles which are also placed over and under the sample. This system enables us to obtain the heating rate of over 1000"0C/min and cooling rate of -500"0C/min for an alloy of 10 mm diameter and 30 mm length. The performance is sufficient to carry out some kinetics measurements in real-time neutron diffraction by the use of a position-sensitive detector. This kind of experiment is demonstrated by the observation of the relaxation process of order--disorder transitions in CuZn and Ni_3Mn alloys.

381

Fundamental concepts of digital image processing  

Science.gov (United States)

The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A medical decision might be made while the patient is still under observation rather ...

1983-03-01

382

Formation of pentagonal Cu nano wires  

Energy Technology Data Exchange (ETDEWEB)

The development of nano/molecular devices will require atomic-sized electrical contacts or nano metric conductors for wiring. As metal nano wires exhibit quantized conductance at room temperature, quantum transport effects will play an important role in the practical implementation of nano devices. As copper is currently used as interconnecting metal in standard microelectronics, the characterization of Cu nano wire properties deserves special attention. In this work, we show a detailed study of structural and electronic properties of atomic-sized Cu wires. In particular, we have established a complete correlation between the conductance and the structure by associating real-time atomic resolution transmission electron microscopy imaging with molecular dynamic simulations, conductance measurements and conductance calculations. Our study has revealed the structural relaxation of Cu wires forming a pentagonal atomic arrangement along the [110] direction that allows a ...

2004-07-01

383

Flood scour monitoring system using fiber Bragg grating sensors  

Science.gov (United States)

The exposure and subsequent undermining of pier/abutment foundations through the scouring action of a flood can result in the structural failure of a bridge. Bridge scour is one of the leading causes of bridge failure. Bridges subject to periods of flood/high flow require monitoring during those times in order to protect the traveling public. In this study, an innovative scour monitoring system using button-like fiber Bragg grating (FBG) sensors was developed and applied successfully in the field during the Aere typhoon period in 2004. The in situ FBG scour monitoring system has been demonstrated to be robust and reliable for real-time scour-depth measurements, and to be valid for indicating depositional depth at the Dadu Bridge. The field results show that this system can function well and survive a typhoon flood.

2006-12-01

384

Expression of suppressor of cytokine signaling 1 and 3 in ligature-induced periodontitis in rats  

British Library Electronic Table of Contents (United Kingdom)

Objective: : Evaluate expression of inducible negative regulators of JAK/STAT pathway and their target proteins during the course of ligature-induced experimental periodontal disease in rats. Design: : Rats were sacrificed 07, 15 and 30days after disease induction for histological evaluation of periodontal inflammation and macroscopic analysis of alveolar bone loss. SOCS expression and the activation status of STAT1 and STAT3 were evaluated in gingival biopsies by real time PCR and Western blot. Results: : Ligature-induced model presented significant progressive bone loss from 7 to 30days. Inflammation was evident and similar for 07 and 15days; however, a decrease on severity at the end of the experimental period was observed. There was a significant (p<0.05) increase on SOCS1 and SOCS3 ge...

2011-01-01

385

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.

2003-04-08

386

Effect of an Ostertagia ostertagi infection on the transcriptional stability of housekeeping genes in the bovine abomasum  

British Library Electronic Table of Contents (United Kingdom)

Quantitative Real-Time PCR (qRT-PCR) is a widely used tool to study host responses against parasites. A crucial step in the gene quantification process is the normalization of the expression data against stable housekeeping genes (HKGs). However, in recent years, several reports have showed that the transcriptional levels of such HKGs can change dramatically, especially when cellular changes appear in the tissues investigated. The aim of the current study was to assess the variability of 11 putative HKGs in bovine abomasal tissue during an infection with the parasitic nematode Ostertagia ostertagi. Gene transcription levels of selected potential HKGs were measured by qRT-PCR and the expression stabilities evaluated using geNorm, NormFinder, and The Mann-Whitney-U test. The analysis showed ...

2011-01-01

387

Dynamic and static error analyses of neutron radiography testing  

Energy Technology Data Exchange (ETDEWEB)

Neutron radiography systems are being used for real-time visualization of the dynamic behavior as well as time-averaged measurements of spatial vapor fraction distributions for two phase fluids. The data in the form of video images are typically recorded on videotape at 30 frames per second. Image analysis of he video pictures is used to extract time-dependent or time-averaged data. The determination of the average vapor fraction requires averaging of the logarithm of time-dependent intensity measurements of the neutron beam (gray scale distribution of the image) that passes through the fluid. This could be significantly different than averaging the intensity of the transmitted beam and then taking the logarithm of that term. This difference is termed the dynamic error (error in the time-averaged vapor fractions due to the inherent time-dependence of the measured data) and is separate from the static error (statistical sampling uncertainty). Detailed analyses of ...

1999-03-01

388

Drug detection in breath: effects of pulmonary blood flow and cardiac output on propofol exhalation  

British Library Electronic Table of Contents (United Kingdom)

Breath analysis could offer a non-invasive means of intravenous drug monitoring if robust correlations between drug concentrations in breath and blood can be established. In this study, propofol blood and breath concentrations were determined in an animal model under varying physiological conditions. Propofol concentrations in breath were determined by means of two independently calibrated analytical methods: continuous, real-time proton transfer reaction mass spectrometry (PTR-MS) and discontinuous solid-phase micro-extraction coupled with gas chromatography mass spectrometry (SPME-GC-MS). Blood concentrations were determined by means of SPME-GC-MS. Effects of changes in pulmonary blood flow resulting in a decreased cardiac output (CO) and effects of dobutamine administration resulting in...

2011-01-01

389

Diffraction Experiments at the IBR-2 Pulsed Reactor with Methane Cold Neutron Source  

CERN Document Server

A new methane cold neutron source has been tested at the IBR-2 pulsed reactor at the Frank Laboratory of Neutron Physics. In a paper the results of experiments at neutron diffractometers HRFD and DN-2 which are placed at the IBR-2 from the methane moderator side are given. A comparison with the results obtained with the conventional water comb-like moderator is performed. The perspectives of the cold source for various kinds of neutron diffraction experiments, including atomic and magnetic structural analysis and real time experiments are discussed. It is shown, that for a huge number of the experiments which are performing at both HRFD and DN-2 the methane cold neutron source provides the better conditions than water comb-like moderator.

2000-01-01

390

Development of ultrasonic measurement technique for the determination of vertical two-phase flow pattern  

Energy Technology Data Exchange (ETDEWEB)

In the present study, a new measurement technique which uses a ultrasonic transmission signals in order to determine the vertical two phase flow pattern even under high pressure condition. The ultrasonic measurement system developed in the present study not only provides the measurement functions required for the determination of vertical two phase flow pattern but also makes the real time determination possible. The developed ultrasonic measurement system accurately determined the various vertical two phase flow patterns such as bubbly, slug, churn, annular flow etc. In addition to the determination of flow patterns, qualitative informations for each flow pattern can be obtained, which include void fraction in bubbly flow, length of slug bubble and liquid tail characteristics in slug flow, and stable or transient condition of flow pattern, etc. 13 refs., 24 figs., 3 tabs. (Author)

2002-03-01

391

Design of the decision aiding system for the control of the research nuclear reactor; Conception d'un systeme d'aide a la decision pour le controle d'un reacteur nucleaire de recherche  

Energy Technology Data Exchange (ETDEWEB)

Intelligent and decision aiding systems as support to operators are becoming increasingly a necessity in nuclear installations and in nuclear reactors in particular, specially after the Tree Mile Island. Development of new technologies based on linguistic approaches such as fuzzy logic has given rise to much interest during the last years. Fuzzy logic controller (FLC) has many advantage compared to conventional controllers using classical techniques. The aim of the present work is to use a fuzzy logic controller in parallel to actual semi-automatic controller in order to supervise in real time the operation of the research nuclear reactor. The principal of this controller is based on rules which are established previous from experiment using the semi-automatic controller and from the knowledge of the operators. (authors)

2003-07-01

392

Delay-Limited Cooperative Communication with Reliability Constraints in Wireless Networks  

CERN Document Server

We investigate optimal resource allocation for delay-limited cooperative communication in time varying wireless networks. Motivated by real-time applications that have stringent delay constraints, we develop a dynamic cooperation strategy that makes optimal use of network resources to achieve a target outage probability (reliability) for each user subject to average power constraints. Using the technique of Lyapunov optimization, we first present a general framework to solve this problem and then derive quasi-closed form solutions for several cooperative protocols proposed in the literature. Unlike earlier works, our scheme does not require prior knowledge of the statistical description of the packet arrival, channel state and node mobility processes and can be implemented in an online fashion.

2009-01-01

393

Control area performance improvement by extended security constrained economic dispatch  

Energy Technology Data Exchange (ETDEWEB)

An algorithm for solving the extended security constrained economic dispatch (ESCED) problem with real-time economic dispatch grade speed and reliability is presented. The ESCED problem is formulated by adding regulating margin and ramp rate constraints to the network security constrained economic dispatch problem previously solved by the CEDC algorithm. Starting with Newton`s method to optimize the Lagrangian, the ESCED is developed by superimposing on Newton`s method eight major components called Tracking Start Initialization, Hessian Pre-Elimination, Implicit Dual Variable Calculations, Regulating Margin Sensitivity Coefficient Calculations, Traumatic Event Evaluation, Constraint Relaxation, Implicit Ramp Rate Constraint Implementation, and Relaxed Incremental Cost Calculations. Test results are also presented.

1997-02-01

394

Competitive adsorption of binary mixture of Leptospirillum ferriphilum and Acidithiobacillus caldus onto pyrite  

British Library Electronic Table of Contents (United Kingdom)

Leptospirillum ferriphilum and Acidithiobacillus caldus are two important acidophilic microorganisms involved in iron and sulfur oxidation during bioleaching. Cell adsorption to mineral surfaces is important for the direct leaching or contact leaching of minerals. In this study, we report the competitive adsorption of binary mixtures of L. ferriphilum LF-104 and A. caldus MTH-04 onto pyrite surfaces. The Langmuir adsorption parameter (CAm) indicated that these two bacteria underwent competitive adsorption to pyrite. Real-time quantitive PCR was used to quantify the relative amounts of L. ferriphilum and A. caldus adsorbed onto the surfaces of pyrite following exposure to a mixture of these two organisms. The adsorption of L. ferriphilum was not affected by A. caldus. However, adsorption of...

2010-01-01

395

Cleansing methodology of sites and its applications  

International Nuclear Information System (INIS)

The Commissariat a l'Energie Atomique (CEA, French Atomic Energy Commission) has set up over the last 10 years an innovative methodology aiming at characterizing radiological contaminations. The application of the latter relies on various tools such as expertise vehicles with impressive detection performances (VEgAS) and recently developed software platform called Kartotrak. A Geographic Information System tailored to radiological needs constitutes the heart of the platform; it is surrounded by several modules aiming at sampling optimization (Stratege), data analysis and geostatistical modeling (Krigeo), real-time monitoring (Kartotrak- RT) and validation of cleaning efficiency (Pescar). This paper presents the different tools which provide exhaustive instruments for the follow-up of decontamination projects, from doubt removal to the verification of the decontamination process. (authors)

2009-10-12

396

Assessing the effect of an antimicrobial wound dressing on biofilms  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT To date the effect of silver-containing wound dressings on biofilms, known to be present in chronic wounds, has not been determined or documented. In this current study, we aimed to determine the antimicrobial effect of a silver-containing dressing on biofilms grown in a chambered slide model. Before the addition of a wound dressing onto a 24-hour biofilm, composed of either Pseudomonas aeruginosa, Enterobacter cloacae, Staphylococcus aureus, or a mixed bacterial community, a fluorescent dye was applied. This enabled the viability of sessile bacteria to be monitored in real-time, using a rapid form of confocal laser scanning microscopy over a contact time period of 48 hours. By analyzing all the three-dimensional data generated from the confocal time-lapse sequences, 90% of all se...

2008-01-01

397

Articulated tool provides flexibility, accuracy and lower costs  

Energy Technology Data Exchange (ETDEWEB)

A new German-engineered articulated drilling tool that can take the vertical to the horizontal, using about eight metres of curve, was described. The Articulate Downhole Motor has the capability to run radii as long as 57 metres (the usual requirement is 15 metres), under full control. Its ability to rotate and slide while maintaining control is one of the major positives of the technology. The technology also includes a `positive` communication system in its steering tool. The deployment of the positive pulse retrievable measurement-while-drilling (MWD) system brings real-time tool face orientation and hole direction to the surface. In using the tool, formation composition is not an issue; it is designed to withstand any environment.

1996-12-01

398

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

399

An analytical framework for data stream mining techniques based on challenges and requirements  

CERN Document Server

A growing number of applications that generate massive streams of data need intelligent data processing and online analysis. Real-time surveillance systems, telecommunication systems, sensor networks and other dynamic environments are such examples. The imminent need for turning such data into useful information and knowledge augments the development of systems, algorithms and frameworks that address streaming challenges. The storage, querying and mining of such data sets are highly computationally challenging tasks. Mining data streams is concerned with extracting knowledge structures represented in models and patterns in non stopping streams of information. Generally, two main challenges are designing fast mining methods for data streams and need to promptly detect changing concepts and data distribution because of highly dynamic nature of data streams. The goal of this article is to analyze and classify the application of diverse data mining techniques in ...

2011-01-01

400

An adaptive power system stabilizer based on the self-optimizing pole shifting control strategy  

Energy Technology Data Exchange (ETDEWEB)

An adaptive power system stabilizer (APSS) employing a new self-optimizing pole shifting control strategy and its application to a power system are described in this paper. Based on an identified model of the system, the control is computed by an algorithm which shifts the closed-loop poles of the system to some optimal locations inside the unit circle in the z-domain to minimize a given performance criterion. With the self-optimization property, outside intervention in the controller design procedure is minimized, thus simplifying the tuning procedure during commissioning. Also, a new method of calculating the variable forgetting factor in real-time parameter identification is discussed. Studies show that the proposed APSS can provide good damping of the power system over a wide operating range and significantly improve the dynamic performance of the system.

1993-12-01

401

Amyloid oligomers: spectroscopic characterization of amyloidogenic protein states  

British Library Electronic Table of Contents (United Kingdom)

It is assumed that protein fibrils manifested in amyloidosis result from an aggregation reaction involving small misfolded protein sequences being in an `oligomeric' or `prefibrillar' state. This review covers recent optical spectroscopic studies of amyloid protein misfolding, oligomerization and amyloid fibril growth. Although amyloid fibrils have been studied using established protein-characterization techniques throughout the years, their oligomeric precursor states require sensitive detection in real-time. Here, fluorescent staining is commonly performed using thioflavin T and other small fluorescent molecules such as 4-(dicyanovinyl)- julolidine and 1-amino-8-naphtalene sulphonate that have high affinity to hydrophobic patches. Thus, populated oligomeric intermediates and related `pre...

2010-01-01

402

Advanced Monitoring and Control of Multi monomer System in Emulsion Polymerization  

British Library Electronic Table of Contents (United Kingdom)

Abstract A control framework was developed for real time implementation of optimal control of emulsion polymerization with multiple monomers by integrating model based algorithms with software engines. The developed system was applied for controlling conversion, particle size, molar mass, and polymer composition using model predictive control (MPC) based on mechanistic models for emulsion polymerization. The control formulation was extended to account for existing process constraints on the input, input moves, and solids content. On experimental testing, the developed control scheme was found to achieve the desired objectives without violating the process constraints and showed good robustness in rejecting disturbances. Improvements in the process operation and polymer property control wer...

2010-01-01

403

Activation of rapid signaling pathways and the subsequent transcriptional regulation for the proliferation of breast cancer MCF-7 cells by the treatment with an extract of Glycyrrhiza glabra root  

British Library Electronic Table of Contents (United Kingdom)

Glycyrrhiza glabra root is one of the common traditional Chinese medicines and used as flavoring and sweetening agents for tobaccos, chewing gums, candies, toothpaste and beverages. While glycyrrhizin is one of the main components in the extract of G. glabra root and has been characterized, the other components have not been well characterized. The mechanism of growth activation of breast cancer MCF-7 cells, including the activation of Erk1/2 and Akt, and the transcriptional regulation of estrogen-responsive genes, was examined by means of sulforhodamine B, luciferase reporter gene, real-time RT-PCR and Western blotting assays after the induction of the cells with the extract of G. glabra root. The extract has similar activity to that induced by 17b-estradiol (E2), although glycyrrhizin di...

2007-01-01

404

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. (authors)

2008-05-01

405

A self-tuning power system stabilizer based on artificial neural network  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a systematic approach for designing a self-tuning power system stabilizer (PSS) based on artificial neural network (ANN). An ANN is used for self-tuning the parameters of PSS in real-time. The nodes in the input layer of the ANN receive generator terminal active power (P), reactive power (Q), and voltage (V{sub t}), while the nodes in the output layer provide the optimum PSS parameters, e.g. stabilizing gain (K{sub STAB}), time constants (T{sub 1} and T{sub 2}). A new approach for the selection of number of neurons in the hidden layer has been proposed. Investigations reveal that the dynamic performance of the system with self-tuning PSS based on ANN (ST-ANNPSS) is quite robust over a wide range of loading conditions and equivalent reactance, X{sub e}. (Author)

2004-07-01

406

A novel in vitro flat-bed perfusion biofilm model for determining the potential antimicrobial efficacy of topical wound treatments  

British Library Electronic Table of Contents (United Kingdom)

Abstract Aims: To develop an in vitro flat-bed perfusion biofilm model that could be used to determine the antimicrobial efficacy of topically applied treatments. Methods and Results: Pseudomonas aeruginosa and Staphylococcus aureus biofilms were grown within continuously perfused cellulose matrices. Enumeration of the biofilm density and eluate was performed at various sampling times, enabling determination of the biofilm growth rate. Two antimicrobial wound dressings were applied to the surface of mature biofilms and periodically sampled. To enable real-time imaging of biofilm growth and potential antimicrobial kinetics, a bioluminescent Ps. aeruginosa biofilm was monitored using low-light photometry. Target species produced reproducible steady-state biofilms at a density of c. 107 per b...

2009-01-01

407

A novel gamma scanning system for on-line diagnostic inspection of industrial process columns  

International Nuclear Information System (INIS)

A computerised gamma scanning facilities for on-line investigation of industrial process columns and vessels has been developed by the Malaysian Nuclear Agency (Nuclear Malaysia). The technology, based on the principle of gamma-ray absorption, has been successfully applied for real-time troubleshooting, process investigation and predictive maintenance of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the surrounding region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, presents a number of case studies. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (Author)

408

A multi level analysis of non significant counseling effects in a randomized smoking cessation trial  

British Library Electronic Table of Contents (United Kingdom)

Abstract Aims To determine, in the context of a trial in which counseling did not improve smoking cessation outcomes, whether this was due to a failure of the conceptual theory identifying treatment targets or the action theory specifying interventions. Design Data from a randomized clinical trial of smoking cessation counseling and bupropion SR were submitted to multi level modeling to test whether counseling influenced real time reports of cognitions, emotions and behaviors, and whether these targets predicted abstinence. Setting Center for Tobacco Research and Intervention, Madison, WI. Participants A total of 403 adult, daily smokers without contraindications to bupropion SR use. Participants were assigned randomly to receive individual counseling or no counseling and a 9 week course o...

2010-01-01

409

Void fraction measurements using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two-phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. An air-water flow system was constructed to simulate vapor conditions encountered in a fluid flow duct. Air was injected into the bottom of the duct at flow rates up to 0.47 {ell}/s (1 ft{sup 3}/min). The water flow rate was varied between 0 and 3.78 {ell}/min (0 to 1 gal/min). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10{sup 6} n/cm{sup 2}{center_dot}s{sup {minus}1} directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5-cm (2-in.)-thick aluminum support plates placed on ...

1995-09-01

410

Void fraction measurements using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. To simulate vapor conditions encountered in a fluid flow duct, an air-water flow system was constructed. Air was injected into the bottom of the duct at flow rates up to 0.47 I/s (1 cfm). The water flow rate was varied between 0--3.78 I/m (0--1 gpm). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10{sup 6}n/cm{sup 2}/s directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5 cm (2 in.) thick aluminum support plates placed on both sides of the duct wall. Image analysis techniques ...

1992-12-31

411

Void fraction measurements using neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two-phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. An air-water flow system was constructed to simulate vapor conditions encountered in a fluid flow duct. Air was injected into the bottom of the duct at flow rates up to 0.47 ell/s (1 ft"3/min). The water flow rate was varied between 0 and 3.78 ell/min (0 to 1 gal/min). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10"6 n/cm"2#centre dot#s"-"1 directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5-cm (2-in.)-thick aluminum support plates placed on both sides of the duct wall. ...

1995-01-01

412

Real-time neutron radiography at Texas A and M University  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV image (512x512x8 bit) ...

1990-12-20

413

Real-time neutron radiography at Texas A and M University  

International Nuclear Information System (INIS)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV image (512x512x8 bit) ...

1990-12-01

414

Monitoring leakages on oil production offloading at open seas using statistics associated with mass balance methods  

Energy Technology Data Exchange (ETDEWEB)

Pipeline leak detection technologies can be classified according to their specificity, such as their application to offshore or onshore installations or to multi-phase or single-phase flow regimes. They can also be classified according to the technology on which they are based. Available technologies can be categorized into the following 4 groups: (1) compensated mass balance, solving steady state equations which model a specific pipeline, known as real time mode (RTM), (2) the same as group 1, but solving transient equations, known as real time transient model (RTTM), (3) pressure wave behavior, and (4) statistical modeling. Hybrids schemes can also be found. Effective leak detection systems are needed to address the increasing transformation of very large crude cargo (VLCC) ships into floating production, storage and offloading (FPSO) systems. These operations make use of short and large diameters ...

2004-07-01

415

Methodology for the development and the UML (unified modified language) simulation of data acquisition and data processing systems dedicated to high energy physics experiments; Methodologie de developpement et de modelisation UML des systemes d'acquisition et de traitement en temps reel pour les experiences de physique des hautes energies  

Energy Technology Data Exchange (ETDEWEB)

The increasing complexity of the real-time data acquisition and processing systems (TDAQ: the so called Trigger and Data AcQuisition systems) in high energy physics calls for an appropriate evolution of development tools. This work is about the interplay between in principle specifications of TDAQ systems and their actual design and realization on a concrete hardware and software platform. The basis of our work is to define a methodology for the development of TDAQ systems that meets the specific demands for the development of such systems. The result is the detailed specification of a 'methodological framework' based on the Unified Modeling Language (UML) and designed to manage a development process. The use of this UML-based methodological framework progressively leads to the setting up of a 'home-made' framework, i.e. a development tool that comprises reusable components and generic architectural elements adapted to TDAQ ...

2002-09-01

416

Host based internet protocol (IP) packet analysis to enhance network security  

International Nuclear Information System (INIS)

Data communication in a computer network environment is facing serious security threats from numerous sources such as viruses, worms, Zombies etc. These threats can be broadly characterized as internal or external security threats. Internal threats are mainly attributed to sneaker-nets, utility modems and unauthorized users, which can be minimized by skillful network administration, password management and optimum usage policy definition. The external threats need more serious attention as these attacks are mostly coming from public networks such as Internet. Frequency and complexity of such attacks is much higher as compared to internal attacks. This paper presents a host based network layer screening of external and internal IP packets for logging, analyzing and real-time detection of possible IP spoofing and Denial of Service attacks. This work can also be used in tuning security rules definition for gateway firewalls. Software has been developed which ...

2007-01-01

417

Ground- and space-based temperature and humidity retrievals: Statistical evaluation  

Energy Technology Data Exchange (ETDEWEB)

A near-real-time integrated temperature and water vapor sounding system has been designed and in operation since June 1993. It combines hourly data from the ground-based radio acoustic sounding system (RASS), a two-channel microwave radiometer, standard surface meteorological instruments, a lidar ceilometer, and the Aerodynamic Research Incorporated Communication, Addressing and Reporting System aboard commercial airlines with space-based data from the TIROS-N Operational Vertical Sounder (TOVS). The physical retrieval algorithm provided by the International TOVS Processing Package is used for combining the ground- and space-based temperature and humidity profiles. The first-guess profiles of temperature and humidity required by the physical retrieval algorithm are obtained by using a statistical inversion technique and the ground-based remote sensors measurements. Statistical error estimates are presented for the hourly, near-real-time, ...

1996-03-01

418

Gas emergency management - safety and reliability of supply - remote management of distribution system through computer assisted dispatching of emergency events; Gestion des urgences - securite et fiabilite de la distribution du gaz gestion des urgences a l'aide d'un systeme informatique integre  

Energy Technology Data Exchange (ETDEWEB)

Gas distribution companies have long since paid great attention to improving the quality and safety of the gas supply service to the consumer. In particular the management of gas emergencies has always been a responsibility taken seriously by all sectors of the gas industry. Over the last few years, however, the concept and practices in risk management have been changing rapidly. This has involved gas companies in an on-going attempt to successfully define and establish clear computer assisted risk management practices. Risk management is the systematic use of management policy, procedures and means, with the aim to protect employees, the public, the environment and properties at an acceptable cost. This paper has the purpose of presenting: - the computer software of gas emergency management in use at Italgas S.p.A. for testing the performance of gas distribution networks on a 'real-time' basis and therefore selecting effective action for solving ...

2000-07-01

419

Experimental studies of compact real-time neutron dosimeters  

International Nuclear Information System (INIS)

Full text: Semiconductor detectors coated with boron or lithium compounds have been studied for neutron detection for decades but, until recently, have been limited to thermal neutron detection efficiencies of less than 5%. We reported previously on development and simulation studies of perforated detectors whose perforations are filled with neutron-reactive material in order to produce higher detection efficiencies. Incorporation of bare and cadmium-backed detectors into battery-powered devices with low-power electronics enables us to produce compact personal neutron dosimeters that provide LED readout of counts, which can be related approximately to neutron dose. We report here on experimental studies with such compact devices; devices capable of direct readout in dose units are anticipated. The thermal and epithermal neutron flux densities from the tangential beam tube of the TRIGA Mark II reactor at Kansas State University were measured. Then, thermoluminescent dosimeters (some ...

2008-06-01

420

Evaluation of NucliSens easyMAG for automated nucleic acid extraction from various clinical specimens.  

Science.gov (United States)

The objectives of this study were to evaluate the performance of the NucliSens easyMAG platform for nucleic acid extraction from different clinical specimens compared to NucliSens miniMAG platform and manual QIAGEN extraction. The NucliSens easyMAG and the NucliSens miniMAG showed equal performance on 215 throat swabs since real-time nucleic acid sequence-based amplification scored the same samples positive for Mycoplasma pneumoniae (n=9) and Chlamydia pneumoniae (n=5) RNAs, although internal control RNA was slightly better detected with the NucliSens easyMAG (99.3% versus 96.8%). NucliSens easyMAG extracted nucleic acids more efficiently (higher recovery and/or fewer inhibitors) compared to QIAGEN extraction by showing, on average, lower Ct values in real-time LightCycler PCR, although 4 individual specimen out of 45 were found positive only with QIAGEN. For nine M. pneumoniae-positive throat swabs, the mean difference in Ct values between ...

2006-12-13

421

Effect of gamma radiation on electrical and optical properties of (TeO_2)_0_._9 (In_2O_3)_0_._1 thin films  

International Nuclear Information System (INIS)

We have studied in detail the gamma radiation induced changes in the electrical properties of the (TeO_2)_0_._9 (In_2O_3)_0 _._1 thin films of different thicknesses, prepared by thermal evaporation in vacuum. The current-voltage characteristics for the as-deposited and exposed thin films were analysed to obtain current versus dose plots at different applied voltages. These plots clearly show that the current increases quite linearly with the radiation dose over a wide range and that the range of doses is higher for the thicker films. Beyond certain dose (a quantity dependent on the film thickness), however, the current has been observed to decrease. In order to understand the dose dependence of the current, we analysed the optical absorption spectra for the as-deposited and exposed thin films to obtain the dose dependences of the optical bandgap and energy width of band tails of the localized states. The increase of the current with the gamma radiation dose may be attributed partly to ...

2011-02-01

422

Development of a neutron/. gamma. ray radiation monitor  

Energy Technology Data Exchange (ETDEWEB)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized ...

1983-01-01

423

Development of a neutron/#gamma# ray radiation monitor  

International Nuclear Information System (INIS)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized ...

1983-01-01

424

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

Energy Technology Data Exchange (ETDEWEB)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.10{sup 11} n*cm{sup 2}/s. This facility will be based on a conical neutron collimator with two circular ...

2009-07-01

425

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

International Nuclear Information System (INIS)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.1011 n*cm2/s. This facility will be based on a conical neutron collimator with two circular diaphragms with ...

2009-06-07

426

Development of a Neutron/gamma Ray Radiation Monitor.  

Science.gov (United States)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation ...

1983-01-01

427

A wavelet-fuzzy combined approach for classification and location of transmission line faults  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a real-time wavelet-Fuzzy combined approach for digital relaying. The algorithm for fault classification employs wavelet multi resolution analysis (MRA) to overcome the difficulties associated with conventional voltage and current based measurements due to effect of factors such as fault inception angle, fault impedance and fault distance. The proposed algorithm for fault location, different from conventional algorithms that are based on deterministic computations on a well-defined model to be protected, employs wavelet transform together with fuzzy logic. The wavelet transform captures the dynamic characteristics of the non-stationary transient fault signals using wavelet MRA coefficients. The fuzzy logic is employed to incorporate expert evaluation through fuzzy inference system (FIS) so as to extract important features from wavelet MRA coefficients for obtaining coherent conclusions regarding fault location. Computer simulations using MATLAB ...

2007-11-15

428

A combined real time wide range energy neutron dosimeter and survey meter for high neutron dose rates with Si surface barrier detectors  

International Nuclear Information System (INIS)

The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene radiators was investigated. This dosimeter can give a rough estimation of the neutron spectrum by ...

1983-06-01

429

A REAL-TIME COAL CONTENT/ORE GRADE (C2OC) SENSOR  

Energy Technology Data Exchange (ETDEWEB)

This is the final report of a three year DOE funded project titled ''A real-time coal content/ore grade (C{sub 2}OG) sensor''. The sensor, which is based on hyperspectral imaging technology, was designed to give a machine vision assay of ore or coal. Sensors were designed and built at Resonon, Inc., and then deployed at the Stillwater Mining Company core room in southcentral Montana for analyzing platinum/palladium ore and at the Montana Tech Spectroscopy Lab for analyzing coal and other materials. The Stillwater sensor imaged 91' of core and analyzed this data for surface sulfides which are considered to be pathfinder minerals for platinum/palladium at this mine. Our results indicate that the sensor could deliver a relative ore grade provided tool markings and iron oxidation were kept to a minimum. Coal, talc, and titanium sponge samples were also imaged and analyzed for content and grade with promising results. This ...

2005-04-01

430

Studies on radioactive liquid waste treatment by reverse osmosis  

Energy Technology Data Exchange (ETDEWEB)

Reverse osmosis is a simple process and has relatively high decontamination factor compared to other processes used for the treatment of radioactive liquid waste. Furthermore the quantity of secondary waste of this process is small. In this study, test solution containing nine elements such as cesium, strontium, cobalt etc. in chloride forms are treated by reverse osmosis. Permeate rate decreases as the increase of osmotic pressure of feed solution and is expressed by linear equation. Decontamination factor of cations of univalency is more than ten, and about one tenth of that of bivalency. Decontamination factors of all the elements used in this experiment are approximately estimated using the solution-diffusion model.

1982-06-01

431

Studies on radioactive liquid waste treatment by reverse osmosis  

International Nuclear Information System (INIS)

Reverse osmosis is a simple process and has relatively high decontamination factor comparing to other processes used for the treatment of radioactive liquid waste. Furthermore the quantity of secondary waste of this process is small. In this study, test solution containing nine elements such as cesium, strontium, cobalt etc. in chloride forms are treated by reverse osmosis. Permeate rate decreases as the increase of osmotic pressure of feed solution and is expressed by linear equation. Decontamination factor of cations of univalency is more than ten, and about one tenth of that of bivalency. Decontamination factors of all the elements used in this experiment are approximately estimated using the solution-diffusion model. (author).

432

Reversible Movement of Homogenously Nucleated Dislocations in a #beta#-Titanium Alloy  

International Nuclear Information System (INIS)

We demonstrate reversible movement of (1/2)[110](110) dislocation loops generated from nanodisturbances in a #beta#-titanium alloy. High resolution transmission electron microscope observations during an in situ tensile test found three reversible deformation mechanisms, nanodisturbances, dislocation loops and martensitic transformation, that are triggered in turn with increasing applied stress. All three mechanisms contribute to the nonlinear elasticity of the alloy. The experiments also revealed the evolution of the dislocation loops to disclination dipoles that cause severe local lattice rotations.

2009-01-30

433

Magnetization reversal phenomena and domain wall behaviours in nanostructured magnetic systems  

International Nuclear Information System (INIS)

Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)

2001-09-23

434

VSP reverse-time migration  

Energy Technology Data Exchange (ETDEWEB)

VSP reverse-time migration is a well adaptable wave equation migration method. Its control equation not only describes all-direction propagation of seismic wave but also removes interbed multiples. Clearbout's image principle is generalized to determine image conditions, real VSP data are used to determine boundary condition, and two way reflection-free wave equation is solved by making reverse-time extrapolation. In each step of extrapolation, the migration value at relevant image point is obtained by using the image condition. The complete migration of a seismic section is achieved when reverse-time extrapolation reaches the minimum image time. In this paper it is proved theoretically and practically that this method is applicable to any velocity variation and makes the migrated section have both good resolution and high S/N ratio. Besides, this method results in high processing efficiency.

1991-01-01

435

Thio and Seleno Rhodamine Derivatives as Reversal Agents ...  

Science.gov (United States)

... Values of absorption maxima, X.nax, and associated molar extinction coefficients, c, as well as values of the n-octanol/water partition coefficient( ...

2005-09-01

436

Separation of oligo-RNA by reverse-phase HPLC.  

UK PubMed Central (United Kingdom)

A rapid and highly reproducible chromatographic technique has been developed for analysis and purification of complex mixtures of oligoribonucleotides. The method utilizes a column of microparticulate...Full Text Available

1979-10-25

437

Reversing B cell aging  

UK PubMed Central (United Kingdom)

Age-related alterations in the cellular composition of the B lineage are a major cause of the poor antibody response to vaccination and to infectious agents among the elderly population. The mechanisms...Full Text Available

438

Recent Therapy for Reversible Airway Disease  

UK PubMed Central (United Kingdom)

The current therapy for extrinsic and intrinsic asthma, together with that of ‘wheezing bronchitis’, is presented, with special attention to bronchodilators and adrenocorticosteroids....Full Text Available

1976-03-01

439

Orphan GPCR research  

UK PubMed Central (United Kingdom)

Orphan G protein-coupled receptors (GPCRs) are receptors lacking endogenous ligands. Found by molecular biological analyses, they became the roots of reverse pharmacology, in which receptors are attempted...Full Text Available

2008-03-01

440

Numerical Simulation of Quarry Source and Reflection ...  

Science.gov (United States)

... that range from relatively low frequency strong ground motion modeling [Vidale et al., 1985] to high frequency reverse time migration of seismic ...

1990-08-01

441

EFFECTS OF STERIt!ZI#C AGENTS ON HiCROOR6AIISI#S  

Science.gov (United States)

6-Mercaptopurine (6-MP) inhibits the growth of. Escherichia coli B. Growth inhibition is ... reversed by subculture of the cells in 6-mercaptopurine- ...

442

Subcriticality calculations for the FFTF reverse approach to critical experiment  

Science.gov (United States)

The reverse approach to critical (RAC) experiments were performed in the ZPR-IX critical facility at Argonne National Laboratory. One of the major objectives of this project is to determine the adequacy of the low-level flux monitor (LLFM) detectors for initial loading of the Fast Flux Test Facility (FFTF). 5 references. (auth)

1975-01-01

443

Silicon nanopowder as active material for hybrid electrodes of lithium-ion batteries  

British Library Electronic Table of Contents (United Kingdom)

Cycling parameters (reversible specific capacity, first-cycle coulombic efficiency, accumulated irreversible capacity, and reversible capacity retention) of hybrid electrodes based on mechanical mixtures of a silicon nanopowder with KS6 and MAG-20 synthetic graphites and binders of varied nature were subjected to an integrated analysis in comparison with graphite electrodes.

2011-01-01

444

Plasma Flow Equilibrium, Confinement Scaling Laws and Fusion Prospects of a Field Reversed Configuration  

International Nuclear Information System (INIS)

Field reversed configuration (FRC) is a prospective high ? magnetic system for high efficiency D- 3He fusion reactor. Self-consistent FRC plasma profiles and static electric field for reactor calculations are discussed in framework of the model including flow equilibrium and collisionless transport equations. The extrapolations to reactor regimes of plasma confinement scaling laws are considered.

2006-01-01

445

Lipase catalyzed esterification in AOT reverse micelles: a structural study.  

Science.gov (United States)

AOT reverse micelles are used to cosolubilize hydrophilic and hydrophobic reactants of lipase catalysed esterification. Depending on the nature of the alcohol, a drastic change of the initial rate of the esterification is observed. A structural study of the micellar system with and without reactant is undertaken to explain the change in the activity with the various alcohols. PMID:7832997

1995-01-01

446

Hyperfine interactions in HCOOD and DCOOH molecules  

Energy Technology Data Exchange (ETDEWEB)

The method of double microwave--radio-frequency resonance has been used to obtain spectra of the 2/sub 11/reverse arrow2/sub 12/ and 3/sub 21/reverse arrow3/sub 22/ transitions in HCOOD, DCOOH, and HCOOH molecules. The constants of the quadrupole bond of the deuterons have been determined, magnetic interactions being taken into acocunt. A comparison with results of previous studies is given.

1986-05-01

447

Fracture imaging with converted elastic waves  

Energy Technology Data Exchange (ETDEWEB)

This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).

2001-05-29

448

Equine infectious anemia virus and human immunodeficiency virus DNA synthesis in vitro: characterization of the endogenous reverse transcriptase reaction.  

UK PubMed Central (United Kingdom)

The endogenous reverse transcriptase reaction of equine infectious anemia virus (EIAV) has been studied, and conditions allowing synthesis of full-length minus-strand DNA have been determined. In contrast...Full Text Available

1991-04-01

449

2004 Reversible Associations in Structure & Molecular Biology  

Energy Technology Data Exchange (ETDEWEB)

The Gordon Research Conference (GRC) on 2004 Gordon Research Conference on Reversible Associations in Structure & Molecular Biology was held at Four Points Sheraton, CA, 1/25-30/2004. The Conference was well attended with 82 participants (attendees list attached). The attendees represented the spectrum of endeavor in this field coming from academia, industry, and government laboratories, both U.S. and foreign scientists, senior researchers, young investigators, and students.

2005-03-23

450

Use of a static frequency converter for rapid load response in pumped-storage plants  

Energy Technology Data Exchange (ETDEWEB)

Most pumped-storage plants have the capability to operate as synchronous condensers. As such, they can be brought on line very quickly to support system load requirements. However, one of the effects of making a rapid transition from synchronous condenser operation to turbine/governor operation is an initial reverse power flow into the machine. This reverse power flow can be very undesirable at a time when the system is calling for load support. On weak or isolated systems, this reverse power flow can lead to objectionable voltage and frequency dips in the system. With the proper utilization of a static frequency converter (SFC) and its associated controls and auxiliary switchgear systems, the reverse power flow resulting from a transition from synchronous condenser operation can be eliminated. This paper will describe the method by which an SFC system can be used to make this rapid load response in ...

1995-12-01

451

Utilisation of an Air-conditioning System to Control the Levels of Radon and Radon Progeny in a Workplace Environment  

Energy Technology Data Exchange (ETDEWEB)

From long-term real-time radon and radon progeny measurements taken in a relatively large retail store, cyclical patterns were evident, which were found to relate to the overriding influence of the timed air-conditioning system. Concentration of radon, radon progeny and the variability of F factor were found to depend significantly on the intermittent operation of this ventilation-air-conditioning system. After pressure equalisation remedial measures proved ineffective, the air-movement system was utilised to reduce the levels of radon and radon progeny to well within established norms applicable during working hours. It is demonstrated that the average levels for radon and radon progeny are reduced in absolute terms. This amounted to less than 12% of the general level, during designated work periods. Where air movement systems are already installed, as well as other circumstances, their regulation provides an economical solution to meeting legal and other ...

2000-07-01

452

Using light to bioactivate surfaces: A new way of creating oriented, active immunobiosensors  

International Nuclear Information System (INIS)

Ultraviolet light can be used to immobilize biomolecules onto thiol reactive surfaces in order to, e.g., make biosensors. The mechanism involves light-induced formation of free, reactive thiol groups in disulphide containing molecules. This technology allows for the creation of arrays of biomolecules with a high degree of reproducibility, circumventing the need for often expensive nano/micro-dispensing technologies. The ultimate size of the immobilized spots is defined by the focal area of the UV beam. Light-induced immobilization has the added benefit that the immobilized molecules will be spatially oriented and covalently bound to the surface. In this paper, we demonstrate the utility of a sensor array created with the new sensor technology when integrated into a microfluidic system. Protein arrays made using light-induced immobilization showed successful antigen/antibody binding in a flow cell allowing the visualisation of real time binding ...

2007-12-15

453

Use of x-ray imaging for evaluation of superconducting ceramics fabricated by PIT method  

Energy Technology Data Exchange (ETDEWEB)

High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The X-ray imaging provides nondestructive information about the entire width of the ribbon, with far greater speed, lower cost, and more flexibility than the ...

1993-08-01

454

Transient data acquisition techniques under EDS  

Energy Technology Data Exchange (ETDEWEB)

This paper is the first of a series which describes the Enrichment Diagnostic System (EDS) developed for the MARS project at Lawrence Livermore National Laboratory. Although EDS was developed for use on AVLIS, the functional requirements, overall design, and specific techniques are applicable to any experimental data acquisition system involving large quantities of transient data. In particular this paper will discuss the techniques and equipment used to do the data acquisition. Included are what types of hardware are used and how that hardware (CAMAC, digital oscilloscopes) is interfaced to the HP computers. In this discussion the author will address the problems encountered and the solutions used, as well as the performance of the instrument/computer interfaces. The second topic the author will discuss is how the acquired data is associated to graphics and analysis portions of EDS through efficient real time data bases. This discussion will ...

1985-06-01

455

Transcriptome analysis reveals salt-stress-regulated biological processes and key pathways in roots of cotton (Gossypium hirsutum L.).  

Science.gov (United States)

High salinity is one of the main factors limiting cotton growth and productivity. The genes that regulate salt stress in TM-1 upland cotton were monitored using microarray and real-time PCR (RT-PCR) with samples taken from roots. Microarray analysis showed that 1503 probe sets were up-regulated and 1490 probe sets were down-regulated in plants exposed for 3h to 100mM NaCl, and RT-PCR analysis validated 42 relevant/related genes. The distribution of enriched gene ontology terms showed such important processes as the response to water stress and pathways of hormone metabolism and signal transduction were induced by the NaCl treatment. Some key regulatory gene families involved in abiotic and biotic sources of stress such as WRKY, ERF, and JAZ were differentially expressed. Our transcriptome analysis might provide some useful insights into salt-mediated signal transduction pathways in cotton and offer a number of candidate genes as potential markers of tolerance to ...

2011-04-30

456

Time-domain dynamic opto-rheology study of polymer films using step-scan FTIR time-resolved spectroscopy (S{sup 2}FTIR TRS)  

Energy Technology Data Exchange (ETDEWEB)

Step-scan Fourier transform infrared spectroscopy in conjunction with impulse stress on polymer films has been used to monitor dynamic rheological responses in real time. A novel piezo-electrically-driven polymer microrheometer was employed to apply repetitive impulses to the polymer sample while time-domain spectra were recorded. Recent results include the study of both semi-crystalline polymers such as isotactic polypropylene (iPP) and elastomers such as Estane polyester/polyurethane copolymer and Kraton tri-block copolymer. The spectral changes of iPP are consistent with frequency-domain results. For iPP at room temperature, large differences in the response times of different absorption bands are not seen. However, the orientation response of the CH{sub 3} rocking mode is slightly slower than the responses of the backbone modes. To the authors` knowledge, this is the first reported successful step-scan FTIR time-domain dynamic polymer ...

1998-07-01

457

The formation mechanism of textured YBa sub 2 Cu sub 3 O sub 7-. delta  

Energy Technology Data Exchange (ETDEWEB)

The formation of textured YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} (123) from a liquid phase according to the peritectic reaction Y{sub 2}BaCuO{sub 5} (211) + liquid {yields} 123 was analyzed using real-time analysis techniques of high-temperature X-ray diffraction, high-temperature optical microscopy, and environmental scanning electron microscopy (ESEM). Results were coupled with conventional ''post-mortem'' SEM analysis of processed samples at various stages of microstructural development. Observations of 123 formation and growth from the peritectic melt permit the conclusion that the presence of crystalline 211 primarily acts as a source of yttrium. The slow dissolution of 211 into the yttrium deficient liquid phase is the rate controlled step in the formation and growth of the textured 123, rather that its acting as a nucleation site for 123 grains as has been widely assumed. (orig.).

1992-05-20

458

The epidemiology of gallstone disease in Rome, Italy. Part I. Prevalence data in men. The Rome Group for Epidemiology and Prevention of Cholelithiasis (GREPCO).  

Science.gov (United States)

A population of male civil servants in Rome, Italy, was investigated to determine the prevalence of symptomatic and asymptomatic gallstone disease. Field activities started in December, 1982 and were concluded in July, 1984. Diagnosis was made using real-time ultrasonography. Participation in the study was 71.5%. Prevalence of gallstone disease was 8.2% and increased with age from 2.3% in the 20- to 25-year-old age group to 14.4% in the 60- to 69-year-old age group, based on both presence of gallstones and history of cholecystectomy. About one-third of the subjects with gallstone disease had previously been submitted to cholecystectomy. Only 7.7% of the subjects with presence of gallstones complained of at least one episode of biliary pain in the preceding 5 years. Frequency of "minor" dyspeptic symptoms was not different between men with and those without gallstones. PMID:3391519

459

The construction of earthquake damage estimation system for city gas supply system  

Energy Technology Data Exchange (ETDEWEB)

The regular occurrence of large-scale earthquakes in Japan necessitates the use of earthquake disaster prevention systems that focus on gathering damage information on gas supply facilities immediately after an earthquake strikes and minimizing the damage. This paper discussed the development of an earthquake damage estimation system for city gas pipelines that can show damage information in real-time by using earthquake records obtained from densely deployed earthquake observation networks and the most advanced telecommunication and information technologies. The paper summarized the earthquake damage estimation system (EDES) and Toho Gas disaster prevention measures. Specific topics that were discussed included the Toho Gas supply method; earthquake countermeasures; construction of computer systems; normal and emergency operation of EDES; and verification of functions in actual earthquakes. It was concluded that when there is an emergency, the EDES functions as an ...

2010-07-01

460

Summary report, California Department of Forestry and Fire Protection evaluation of full-face air-purifying respirators for wildland fire fighting use  

Energy Technology Data Exchange (ETDEWEB)

Wildland fire suppression personnel employed by the CDF do not currently have the equipment to protect themselves from the short-term acute affects of smoke from wildland fires. In addition, no regulations exist that specify appropriate respiratory protection and the current air-purifying respirator technology and carbon monoxide monitoring has not been adapted to fit wildland fire suppression requirements. This three-year limited study evaluated the ability of wildland fire fighters to perform their normal job function while wearing full-face air-purifying respirators. In the first two years of this study we designed, developed and field tested a prototype ``smart`` air-purifying respirator which incorporated a real-time carbon monoxide monitor into a commercial full-face respirator.` Data on carbon monoxide exposure while fighting wildland fires was collected. During the third year of this study we evaluated eight different commercially available full-face ...

1996-02-01

461

Studies of the applicability of opto-electronic devices for instrumentation in high-energy physics. Progress report, June 1, 1981-May 31, 1982  

Energy Technology Data Exchange (ETDEWEB)

Instrumentation research to study the feasibility of using optical data processing techniques to solve real-time pattern recognition problems for high energy physics experiments is now in its second year. During the past year, a prototype optical processor for use in BNL Experiment 702 was conceived and designed, using test data from the experiment and simulating the optical processor in the computer. A number of technical studies have been made, mostly relating to the selection of the optical filter for the processor. Comparisons between natural and synthetic holograms, both bleached and unbleached, have been made. We conclude from these tests that the kinoform, a computer-generated phase hologram, is the optimal choice for this processor. A new method for producing the kinoform has been tried by this group with encouraging results. The optical design for the prototype processor is complete, and the required optical elements, sources, and the detector have all ...

1982-01-01

462

Studies of real-time adaptive optimal excitation controller and adaptive optimal power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

Use of an adaptive optimal control algorithm for two realtime control applications, optimal excitation control of a synchronous generator (OEC) and power system stabilizer (PSS) is described in this paper. Experimental studies on a physical model of a power system show that the proposed OEC and PSS can track the controlled system by parameter identification at different operating conditions. The proposed control algorithm is based on the linear optimal control theory and a special 5th order discrete Riccati equation is solved in each sampling period. The proposed OEC and PSS can always guarantee that in closed loop the controlled system is stable based on the identified parameters. As the actual output of the controlled system and control are directly used in the controller, no observer is required. Also, the proposed OEC and PSS can track the controlled system very fast. A number of tests have been performed. All show satisfactory results.

1992-09-01

463

Shallow hydrothermal regime of the East Brawley and Glamis known geothermal resource areas, Salton Trough, California  

Energy Technology Data Exchange (ETDEWEB)

Thermal gradients and thermal conductivities were obtained in real time using an in situ heat-flow technique in 15 shallow (90 to 150 m) wells drilled between Brawley and Glamis in the Imperial Valley, Southern California. The in situ measurements were supplemented by follow-up conventional temperature logs in seven of the wells and by laboratory measurements of thermal conductivity on drill cuttings. The deltaic sedimentary material comprising the upper approx. 100 m of the Salton Trough generally is poorly sorted and high in quartz resulting in quite high thermal conductivities (averaging 2.0 Wm/sup -1/ K/sup -1/ as opposed to 1.2 to 1.7 for typical alluvium). A broad heat-flow anomaly with maximum of about 200 mWm/sup -2/ (approx. 5 HFU) is centered between Glamis and East Brawley and is superimposed on a regional heat-flow high in excess of 100 mWm/sup -2/ (> 2.5 HFU). The heat-flow high corresponds with a gravity maximum and partially ...

1981-01-01

464

Reducing CSOs and giving the river back to the public: innovative combined sewer overflow control and riverbanks restoration of the St. Charles River in Quebec City.  

Science.gov (United States)

After the construction of its wastewater treatment plants, the City of Quebec began to implement overflow control in wet weather to ultimately meet the effluent discharge objectives, i.e. no more than two overflows per summer season in the St. Lawrence River and no more than four in the St-Charles River. After several years of studies to determine which management strategies would best suit the purpose, and to propose optimum solutions, a first project to implement optimal and predictive management in real time, called "Pilot", came to life in 1999. Construction in phases soon followed and the work was completed in the fall of 2009. As a result, requirements with regard to environmental rejects were met in two sectors, namely the St-Charles River and the Jacques-Cartier Beach, and aquatic recreational activities could resume. Meanwhile, the City also worked at giving back access to the water courses to the public by developing sites at the ...

2011-01-01

465

Pricing of constraints - the England & Wales experience  

Energy Technology Data Exchange (ETDEWEB)

The existence, in real-time, of transmission constraints, demand forecasting errors, generator failures, and other factors impose additional costs through the need to run more expensive generation. These costs can appear as a significant component of the wholesale price to demand served by electricity markets operated over transmission networks. In the England & Wales Pool these costs are passed through directly to supply companies. The Transmission System Operator ({open_quotes}TSO{close_quotes}) can exert significant influence on these costs through improved availability of transmission circuits and through appropriate investment, but has no incentive to do so. Since the inception of the Pool, these costs have increased in level and volatility, and have proved difficult to hedge. In response, St Clements Services were instrumental in assisting Pool members to develop an {open_quotes}Uplift Incentive Management Scheme{close_quotes} which has seen controllable ...

1996-03-01

466

Prevalence of gallstone disease in an Italian adult female population. Rome Group for the Epidemiology and Prevention of Cholelithiasis (GREPCO).  

Science.gov (United States)

A population of female civil servants in Rome, Italy, was investigated to determine the prevalence of symptomatic and asymptomatic gallstone disease and to define the associated factors. Field activities started in February 1981 and concluded in April 1982. Diagnosis was assessed by real time ultrasonography. Prevalence of gallstone disease increased with age from 2.5% in the 20- to 29-year-old age group to 25.0% in the 60- to 64-year-old age group, based on both presence of gallstones and history of cholecystectomy. Only one third of the women with gallstones had complained of at least one episode of biliary pain in the last five years. Frequency of "minor" dyspeptic symptoms was not different between women with and those without gallstones. In a multiple logistic function analysis, a positive association was found between age, body mass index, parity, and prevalence of gallstone disease. No association was demonstrated between the presence of ...

1984-05-01

467

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is compared with an idealized model simulation ...

2007-04-01

468

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the ...

2008-04-15

469

Near-infrared laser desorption/ionization aerosol mass spectrometry for investigating primary and secondary organic aerosols under low loading conditions.  

Science.gov (United States)

A new method, near-infrared laser desorption/ionization aerosol mass spectrometry (NIR-LDI-AMS), is described for the real time analysis of organic aerosols at atmospherically relevant mass loadings. Use of a single NIR laser pulse to vaporize and ionize particle components deposited on an aluminum probe results in minimal fragmentation to produce exclusively intact pseudomolecular anions at [M-H](-). Limits of detection (total particulate mass sampled) for oxidized compounds of relevance to atmospheric primary and secondary organic aerosol range from 89 fg for pinic acid to 8.8 pg for cholesterol. NIR-LDI-AMS was used in conjunction with the University of Vermont Environmental Chamber to study secondary organic aerosol (SOA) formation from ozonolysis of limonene at total aerosol mass loadings ranging from 3.2 to 25.0 ?g m(-3) and with a time resolution of several minutes. NIR-LDI-AMS permitted direct delineation between gas-phase, homogeneous ...

2010-10-01

470

NICE3: Dyebath reuse in carpet manufacturing  

Energy Technology Data Exchange (ETDEWEB)

Fact sheet on an analysis system for dyebath processes in the carpet manufacturing industry written for the NICE3 Program. The Georgia Institute of Technology (G.I.T.) has developed an effective automated dyebath analysis and reuse system that improves the energy, environmental, and economic performance of dyehouse batch operations. The new system enables dyeing solutions to be accurately monitored and adjusted for reuse. According to industry estimates, 160 pounds of water are used to produce each pound of textile product. The current wasteful batch dyeing process requires all water and residual chemicals, as well as the energy required to heat the mixture for dyeing, to be dumped after one application. Spent dyebaths can only be reused after they are sampled, analyzed, and reconstituted, a process requiring labor and expertise that are unavailable in the dyehouses. Therefore, successful commercial reuse depends on an automated analysis system that precisely analyzes dyebath samples ...

1999-09-29

471

Machine vision  

Energy Technology Data Exchange (ETDEWEB)

To keep up with the speeds of modern production lines, most machine vision applications require very powerful computers (often parallel-processing machines), which process millions of points of data in real time. The human brain performs approximately 100 billion logical floating-point operations each second. That is 400 times the speed of a Cray-1 supercomputer. The right software must be developed for parallel-processing computers. The NSF has awarded Rensselaer Polytechnic Institute (Troy, N.Y.) a $2 million grant for parallel- and image-processing software research. Over the last 15 years, Rensselaer has been conducting image-processing research, including work with high-definition TV (HDTV) and image coding and understanding. A similar NSF grant has been awarded to Michigan State University (East Lansing, Mich.) Neural networks are supposed to emulate human learning patterns. These networks and their hardware implementations ...

1989-06-01

472

MIMO (multi-input multi-output) adaptive power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A multivariate adaptive power system stabilizer is proposed. The advantages of using coordinated governor and excitation control are discussed, and the problems associated with constant parameter power system stabilizers (CPSS) are highlighted. The proposed multi-input multi-output (MIMO) power system stabilizer can coordinate the governor and excitation control and can overcome the problems associated with CPSS in power system stabilization. Selective multivariable state modelling, identification and control methods are investigated and the MIMO least squares technique with variable forgetting factor is used for system identification, guaranteeing good parameter tracking after a disturbance. Two multivariable self-tuning algorithms are investigated, the generalized minimum variance control and pole-shifting control algorithms. The multivariable self-searching pole-shifting algorithm is developed. Models of a single machine connected to an infinite bus through a double circuit ...

1988-01-01

473

Laser stabilization at 1536 nm using regenerative spectral hole burning  

International Nuclear Information System (INIS)

Laser frequency stabilization giving a 500-Hz Allan deviation for a 2-ms integration time with drift reduced to 7 kHz/min over several minutes was achieved at 1536 nm in the optical communication band. A continuously regenerated spectral hole in the inhomogeneously broadened "4I_1_5_/_2(1)#->#"4I_1_3_/_2(1) optical absorption of an Er"3"+:Y_2SiO_5 crystal was used as the short-term frequency reference, while a variation on the locking technique allowed simultaneous use of the inhomogeneously broadened absorption line as a long-term reference. The reported frequency stability was achieved without vibration isolation. Spectral hole burning frequency stabilization provides ideal laser sources for high-resolution spectroscopy, real-time optical signal processing, and a range of applications requiring ultra-narrow-band light sources or coherent detection; the time scale for stability and the compatibility with spectral hole burning devices make this technique ...

2001-04-15

474

In-situ focused ion beam (FIB) microscopy at high temperature  

International Nuclear Information System (INIS)

Materials Scientists need information on the kinetics of the microstructural evolution processes that determine the finished microstructure, and hence the properties, of any material. E.g. recrystallisation, grain growth and phase changes. Such kinetic information requires reliable discrimination of differently oriented crystallites and/or different crystal phases coupled with useful spatial resolution and temporal resolution (i.e. high frame rates). These imaging results must be realised from a hot and changing specimen, in an instrument that is compatible with that hot specimen and with a practical specimen heater. Focused Ion Beams (FIB) offer strong contrast between crystallites and phases, and hence offer the ability to discriminate between these features even while imaging at fast frame rates, however their compatibility with hot specimens was unproven. Here we report results from a novel combination of FIB with an in-situ heating stage, to produce in-situ, ...

2008-08-01

475

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the background has been reduced by 1/10 both ...

2007-01-01

476

High frequency individual cylinder estimation for control of diesel engines; Observateur cylindre a cylindre haute frequence pour le controle des moteurs diesel  

Energy Technology Data Exchange (ETDEWEB)

Increasingly stringent pollution regulations have spurred a broad interest in the reduction of engine emissions. Two strategies can be considered: after-treatment or engine emissions reduction. For Diesel engines, after-treatment has a high cost induced by the required technology and implementation issues. In this context, the Highly Premixed Combustion combustion mode (HP C) has emerged as a topic of major interest in recent years. It represents one of the most promising ways for new generation of CI engines using high Exhaust Gas Recirculation (EGR) rates. Experimentation on the test bench brought the proof of significant emission reduction. However, actual vehicle implementation implies frequent transient which fall far beyond steady state experimentation on the test bench. Several key challenges have to be addressed. With this combustion technology; accurate torque balancing at all engine modes is a requirement. Even slight unbalance between the cylinders can have dramatic ...

2006-07-01

477

Hepatobiliary scintigraphy in current pediatric practice  

Energy Technology Data Exchange (ETDEWEB)

Hepatobiliary scintigraphy is the only non-invasive technique providing real-time assessment of hepatocytes function and bile progression from the liver to the intestine; for this reason it is of great importance in the study of jaundice and many other disorders of the liver and the biliary tract in children. Ultrasonography is the initial method of evaluating the intra- and extrahepatic bile ducts dilatation: the differential diagnosis between biliary atresia and neonatal hepatitis cannot however be done without hepatobiliary scintigraphy. Cystic fibrosis patients also require hepatobiliary scintigraphy; liver and biliary tract disease can really occur independently of the underlying disease severity and the presence of steatorrhoea. Hepatobiliary imaging in children who have undergone liver transplantation is of major importance; it can assess vascularity, parenchymal function biliary drainage, possible presence of a bile leak and obstruction; it has very good ...

1998-06-01

478

Growth of tailored sillenite photorefractives for optical correlation  

Science.gov (United States)

Photorefractives, in general, are among the most promising materials solutions to real time optical correlation. Applications include military target recognition and civilian robotic vision. Crystals of sillenite structure photorefractives, Bi12XO20, where X equals Si, Ge, or Ti, have been grown by melt techniques and in the case of bismuth silicon oxide (BSO) and bismuth titanium oxide (BTO) by the hydrothermal method of high-temperature/high-pressure solution growth. The two growth methods are discussed and crystals grown by the two methods are compared in this paper. Optical absorption and TSC studies show that hydrothermal BSO is essentially free of the native antisite Bi defect which usually acts as a donor. These studies also show that the trap density is greatly reduced in hydrothermal material. Preliminary experiments show that hydrothermal BTO crystals have improved properties over melt grown samples. Al and P act as donors and ...

1995-06-01

479

Fly on the wings of the sun - a study of solar-powered aircraft  

Energy Technology Data Exchange (ETDEWEB)

Solar High Altitude Powered Platform (Solar HAPP) aircraft are unmanned remote sensing vehicles designed for cruises lasting up to one year at 20-km altitude, while carrying up to 250 pounds of cameras and electrooptic sensors in an underslung payload pod. It is anticipated that real time IR and UV images of earth features may be more inexpensively and accurately obtained by this means than by the conventional geosynchronous earth resources satellites. Solar HAPPs, with wing spans of over 300 ft and weights of only 2000 lb, require ultralight composite structures with external wire bracing. Solar cells will cover both sides of the vertical wing stabilizers and wing tips, which hinge up in daytime to capture the maximum amount of sunlight. A 15-hp electric propulsion unit drives a low-rpm, large diameter propeller; power will be derived from the solar cells diurnally, and from hydrogen-oxygen fuel cells nocturnally. The fuel gases will be ...

1985-06-01

480

First RAVEN flight set for September  

Energy Technology Data Exchange (ETDEWEB)

An unmanned aerial vehicle called RAVEN, said to be capable of remote tracking of onshore and offshore oil and gas facilities, has been developed by a group of graduate students from Memorial University of Newfoundland. RAVEN is claimed to be capable of performing a number of tasks under its own control without the need for human intervention, including checking onshore pipelines for damage, or scouting the path of hazardous icebergs offshore. The RAVEN was created to meet the need for real time iceberg tracking and early hazard detection, supplementing or replacing the present method of RADARSAT images and tracking by manned aircraft. The RAVEN can be launched from any platform; it can fly under conditions that would be too dangerous for a manned aircraft. Currently in the prototype stage, the first trial flight for the RAVEN is expected to take place in September 2002. The first flight will consist of five GPS waypoints set relatively close ...

2002-08-01

481

FFTF operations: initial operator training simulator program  

International Nuclear Information System (INIS)

This paper describes the Fast Flux Test Facility (FFTF) Operations initial training program utilizing the Operator Training Simulator (OTS). The OTS is a computer-driven system that provides real time response of essential FFTF plant functions to a control room mockup. The FFTF, a 400 Megawatt, three-loop, sodium-cooled fast test reactor will test fuels, materials and equipment for the U.S. Liquid Metal Fast Breeder Reactor Program. Construction is expected to be completed in August 1978. Initial criticality is expected in early 1979. This schedule will require FFTF control room operators to be fully qualified to operate the facility by late 1979. Because FFTF is like no other U.S. nuclear reactor, existing U.S. utility plants could not be depended on to provide highly experienced people to operate FFTF. Therefore, an Operator Training Simulator has been built. The OTS will play a vital role in the formal operator qualification program.

482

Evaluation of the Curve-fitting method and the Horner-plot method for estimation of the true formation temperature using temperature recovery logging data  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the method to estimate the true formation temperature using temperature recovery logging data after the well reach to total depth (T.D.). The method designated as ''Curve-fitting method (CFM)'' is based on mathematical model proposed by Middleton (1979, 1982). The accuracy and applicability of this method are evaluated with several field data and compared advantageously with the Horner-plot method. Then, real-time data acquisition system including interpretation software has also been successfully developed. As a conclusion, the followings are confirmed: (1) The developed CFM can be applicable to the estimation of the true formation temperature even using 24 hours temperature recovery data, although the Horner-plot method might need up to 120 hours recovery data, usually. (2) Though depending upon the quality of the data and/or number of the temperature recovery logging data, it might be possible to estimate ...

1995-01-26

483

Evaluating technologies for tactical information management in net-centric systems  

Science.gov (United States)

Recent trends in distributed real-time and embedded (DRE) systems motivate the development of tactical information management capabilities that ensure the right information is delivered to the right place at the right time to satisfy quality of service (QoS) requirements in heterogeneous environments. A promising approach to building and evolving large-scale and long-lived tactical information management systems are standards-based QoS-enabled publish/subscribe (pub/sub) platforms that enable applications to communicate by publishing information they have and subscribing to information they need in a timely manner. Since there is little existing evaluation of how well these platforms meet the performance needs of tactical information management, this paper provides two contributions: (1) it describes three common architectures for the OMG Data Distribution Service (DDS), which is a QoS-enabled pub/sub platform standard, and (2) it evaluates three implementations of ...

2007-05-01

484

Electrical biasing and voltage contrast imaging in a focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

We present two new techniques that enhance conventional focused ion beam (FIB) system capabilities for integrated circuit (IC) analysis: in situ electrical biasing and voltage contrast imaging. We have used in situ electrical biasing to enable a number of advanced failure analysis applications including (1) real time evaluation of device electrical behavior during milling and deposition, (2) verification of IC functional modifications without removal from the FIB system, and (3) ultraprecision control for cross sectioning of deep submicron structures, such as programmed amorphous silicon antifuses. We have also developed FIB system voltage contrast imaging that can be used for a variety of failure analysis applications. The use of passive voltage contrast imaging for defect localization and for navigation on planarized devices will be illustrated. In addition, we describe new, biased voltage contrast imaging techniques and provide examples of ...

1995-09-01

485

Electric energy storage systems in a market-based economy. Comparison of emerging and traditional technologies  

Energy Technology Data Exchange (ETDEWEB)

Unlike markets for storable commodities, electricity markets depend on the real-time balance of supply and demand. Although much of the present-day grid operate effectively without storage technologies, cost-effective ways of storing electrical energy can make the grid more efficient and reliable. This work addresses an economic comparison between emerging and traditional Electric Energy Storage (EES) technologies in a competitive electricity market. In order to achieve this goal, an appropriate Self-Scheduling (SS) approach must first be developed for each of them to determine their maximum potential of expected profit among multi-markets such as energy and ancillary service markets. Then, these technologies are economically analyzed using Internal Rate of Return (IRR) index. Finally, the amounts of needed financial supports are determined for choosing the emerging technologies when an investor would like to invest on EES technologies. Among available EES ...

2009-12-15

486

Effects of an acute dose of gamma radiation exposure on stem diameter growth, carbon gain, and biomass partitioning in Helianthus annuus  

Energy Technology Data Exchange (ETDEWEB)

Nineteen-day-old dwarf sunflower plants (Helianthus annuus, variety NK894) received a variable dose (0-40 Gy) from a cobalt-60 gamma source. A very sensitive stem monitoring device, developed at Battelle's Pacific Northwest Laboratories, Richland, Washington was used to measure real-time changes in stem diameter. Exposure of plants caused a significant reduction in stem growth and root biomass. Doses as low as 5 Gy resulted in a significant increase in leaf density, suggesting that nonreversible morphological growth changes could be induced by very low doses of radiation. Carbohydrate analysis of 40-Gy irradiated plants demonstrated significantly more starch content in leaves and significantly less starch content in stems 18 days after exposure than did control plants. In contrast, the carbohydrate content in roots of 40-Gy irradiated plants were not significantly different from unirradiated plants 18 days after exposure. These results indicate that ...

1988-05-25

487

Effect of intermetallic growth rate on spontaneous whisker growth from a tin coating on copper  

British Library Electronic Table of Contents (United Kingdom)

Intermetallic compound (IMC) growth at the interface between a Sn coating and a Cu substrate with or without a Ni underlayer and its related stress state was evaluated by real-time measurements using the flexure beam method. For the Sn coating without a Ni underlayer, pyramid-shaped IMC grains of Cu6Sn5 grew along the grain boundaries of Sn from the Cu substrate, especially at the triple grain boundary junctions and the IMC grains rapidly increased their volume during the initial 3?days, During this time, the IMC growth rate was 2.3??m3/day and the compressive stress in the Sn coating rapidly developed and became saturated at about ?11?MPa. In contrast, platelet IMC grains of Ni3Sn4 formed at the surface of the Ni underlayer and the IMCs grew at a rate of 1.0??m3/day for the Sn/Ni coating....

2011-01-01

488

Effect of Nucleus Pulposus Cells Having Different Phenotypes on Chondrogenic Differentiation of Adipose-Derived Stromal Cells in a Coculture System Using Porous Membranes  

British Library Electronic Table of Contents (United Kingdom)

In this study, adipose-derived stem cells (ASCs) were cocultured with nucleus pulposus (NP) cells using a porous membrane to investigate the effect of NP cell phenotype on ASC chondrogenic differentiation. Human NP cells were collected from 14 patients and classified into two groups (normal vs. degenerative) depending on the level of type II collagen, aggrecan (AGG), type I collagen, and bax gene expression. Human ASCs were then cocultured with each group of NP cells on porous membranes in the absence of chondrogenic supplements. After 2 weeks, real-time-polymerase chain reaction results showed that ASCs cocultured with normal NP cells had much higher type II collagen and AGG gene expression than ASCs cocultured with degenerative NP cells. The production of AGG was also observed only in th...

2011-01-01

489

EM-MWD technology; EM-MWD system jitsuyoka gijutsu  

Energy Technology Data Exchange (ETDEWEB)

A project on the title is a special study of TRC (Technology Research Center) Japan National Oil Corporation, which aims at developing a system collecting many data near well bottom while drilling. The project is a 3-year project from 1993 to 1995 succeeding to results of a project on real-time drilling control technology which was finished in fiscal 1992. This paper is a record in fiscal 1993. In 1993, the first year, TRC starts a joint study with relational enterprises aiming at utilizing an EM-MWD (electromagnetic-measurement while drilling) system practically. Based on the past fruit of the study, the EM-MWD system was applied to an highly inclined well or a horizontal well. A total system was constructed, which improved electromagnetic radiation transmission efficiency, and reliability, and workability. An electromagnetic radiation receiver system for an offshore drilling rig was developed. A well bottom tools of 6-3/4 inches outer diameter was developed. An ...

1994-10-31

490

Determining the locations of faults in distribution systems  

Energy Technology Data Exchange (ETDEWEB)

Location of transmission line faults are traditionally estimated by measuring the apparent impedance from a line terminal to the fault and converting the reactive component of the impedance to line length. None of the methods proposed to date address adequately the problems of fault location on distribution systems that have single or multiphase laterals and/or tapped loads. The research for this dissertation resulted in the development of a technique that estimates the location of a shunt fault on a radial distribution system that has several single and/or multiphase laterals. The technique takes into account load taps and non-homogeneity of the system, and has been tested for its ability to handle single-phase-to-ground, two-phase-to-ground, phase-to-phase and balanced three-phase faults. Computer simulations indicate that the technique is more accurate than the reactive component method. Results from a prototype of the technique was tested using simulated voltage and current ...

1998-12-01

491

Data Compression on Zero Suppressed High Energy Physics Data  

CERN Document Server

Future High Energy Physics experiments will produce unprecedented data volumes (up to 1 GB/s [1]). In most cases it will be impossible to analyse these data in real time and they will have to be stored on durable mostly magnetic linear media (e.g. tapes) for later analysis. This threatens to become a major cost factor for the running of these experiments. Here we present some ideas developed together with the Institute of Computer Graphics, Department for Algorithms and Programming on how this volume and the related cost can be reduced significantly. The algorithms presented are not general ones but aimed in particular to physics experiments data. Taking advantage of the knowledge of the data they are highly superior to general ones (Huffman, LZW, arithmetic coding) both in compression rate but more importantly in speed as to keep up with the output rate to modern tape drives. Above standard algorithms are, however, used after the data have ...

1996-01-01

492

Butyrate Induces Expression of 17?-Hydroxysteroid Dehydrogenase Type 1 in HT29 and SW707 Colorectal Cancer Cells  

British Library Electronic Table of Contents (United Kingdom)

Epidemiological studies have revealed that butyrate and 17?-estradiol (E2) may decrease the incidence of colorectal cancer (CRC). In peripheral tissue, E2 can be produced locally by 17?-hydroxysteroid dehydrogenase 1 (HSD17B1) estrone (E1) reduction. Using quantitative real-time polymerase chain reaction and western blotting analysis, we found that sodium butyrate significantly upregulates HSD17B1 long and short transcripts and protein levels in HT29 and SW707 CRC cells. Chromatin immunoprecipitation analysis showed that upregulation of these transcript levels correlated with an increase in binding of Polymerase II to proximal and distal promoters of HSD17B1. Moreover, we observed that upregulation of HSD17B1 protein levels was associated with increased conversion of E1 to E2 in HT29 and S...

2011-01-01

493

Bip overexpression, but not CHOP inhibition, attenuates fatty-acid-induced endoplasmic reticulum stress and apoptosis in HepG2 liver cells  

British Library Electronic Table of Contents (United Kingdom)

Aims: In this study we investigated whether attenuation of endoplasmic reticulum stress (ER stress) could protect HepG2 cells from free fatty acid (FFA)-induced apoptosis. Main methods: Human liver cell line HepG2 cells were exposed to Sodium Palmitate (Pa) or Sodium Oleate (Ol). Apoptosis and ER stress of HepG2 cells were analyzed with flow cytometry, real-time RT-PCR and Western Blotting. An expression plasmid encoding for the ER chaperone immunoglobulin heavy chain-binding protein (Bip) was transfected into HepG2 cells to attenuate ER stress. Small interfering RNA siCHOP was used to knockdown the expression of C/EBP Homologous Protein (CHOP) in HepG2. Key findings: Pa led to cytotoxicity and apoptosis in HepG2 cells in a dose-dependent pattern and also induced ER stress indicated by inc...

2010-01-01

494

Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy  

Energy Technology Data Exchange (ETDEWEB)

A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the dose-reduction potential of ROI imaging can be evaluated. (author)

1997-04-01

495

Authentication via wireless networks  

CERN Document Server

Personal authentication is an important process we encounter almost every day; when we are logging on a computer, entering a company where we work, or a restricted area, when we are using our plastic credit cards to pay for a service or to complete some other financial transaction, etc. In each of these processes of personal authentication some kind of magnetic or optical token is required. But by using novel technologies like mobile computing and wireless networking, it is possible to avoid carrying multitude of ID cards or remembering a number of PIN codes. Article shows how to efficiently authenticate users via Personal Area Networks (PAN) like Bluetooth or IrDA using commonplace AES (Rijndel) or MD5 encryption. This method can be implemented on many types of mobile devices like Pocket PC PDA with Windows CE (Windows Mobile 2003) real-time operating system, or any other customized OS, so we will explain all components and key features of such basic system.

2007-01-01

496

Angular sensitivity distribution of detectors for BNCT  

Energy Technology Data Exchange (ETDEWEB)

The research on the therapy of brain tumors and others by the thermal neutron irradiation using research reactors is to kill tumor cells by accumulating boron at a tumor part, and using {alpha} particles and {sup 7}Li generated by {sup 10}B(n, {alpha}){sup 7}Li reaction of thermal neutrons, which is known as boron neutron capture therapy (BNCT). In Japan Atomic Energy Research Institute, the medical irradiation facility was installed in the thermal neutron column of the JRR-2, and as of March, 1994, 22 cases of irradiation have been carried out. In order to monitor the variation of thermal neutron flux during irradiation, the real time measurement using a simultaneous monitor is carried out, but there is the variation of measured values in the Si semiconductor, p-n junction detector possibly due to its direction dependence. The experiment was carried out to quantity the direction dependence of the detector by using the neutron radiography ...

1995-03-01

497

An adaptive self-optimizing power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A self-optimizing pole-shifting control algorithm has been developed for an adaptive power system stabilizer (APSS) to improve its dynamic performance and autonomous operation. The proposed algorithm deals with the system frequency and time domain characteristics simultaneously to guarantee stability and to enhance the performance of the closed-loop system. The mechanism of discrete control system control limits influencing the closed loop system behaviour is studied. Short-term behaviour is studied by introducing the concept of a short-term behaviour index. With the introduction of dynamic control limits, an effective discrete control system design method is proposed. A PSS oriented power system dynamics simulation package (PSDSP) has been developed. Using the PSDSP, simulation studies were performed with the proposed APSS applied to a single machine and a multi machine power system. The performance of the APSS is satisfactory and is discussed. An Intel iSBC386/21 processor was ...

1994-01-01

498

Adaptive power system stabilizer with previous programming of parameters and artificial neural network; Estabilizador de sistemas de potencia adaptativo com pre-programacao de parametros e rede neural artificial  

Energy Technology Data Exchange (ETDEWEB)

This work presents a digital adaptive Power System Stabilizer (PSS) which operates in a gain scheduling scheme. It`s parameters are designed for a lot of different operating regions in a P x Q plane (active and reactive powers), and saved in a microcomputer real time control. During working, the PSS identifies the present region of operation, and synthesizes its damping signal in accordance with the parameters for that region. As an extension of the method, a neural PSS, which uses the set of parameters of each region as a standard set to train a neural network to form this PSS, is also proposed. The tests presented show good performance for both PSS, when compared to a conventional (non adaptive) one. (author) 10 refs., 5 figs., 1 tab.; e-mail: jalb at guama.cpgee.ufpa.br

1997-12-31

499

Active SWD using monochromatic source wavelet; Tan`itsu shuhasu no shingen hakei wo mochiita active SWD  

Energy Technology Data Exchange (ETDEWEB)

As part of developing efforts for physical exploration technologies for oil reservoirs, this paper describes development of an active seismic while drilling (SWD). The SWD is a seismic exploration method to acquire records equivalent to VSP using seismic waves generated from a bit executing excavation, and is capable of detection and control on a real time basis during the excavation. However, the drawback is that it is subjected to a limitation in the bit. To eliminate this limitation, an artificial seismic source method was devised. In other words, this is an SWD utilizing an artificial seismic source. The contrivance is such that a shot sub containing a magnetic distortion oscillator is attached directly above a bit to generate vibration artificially, and try to utilize larger seismic energy by combining this vibration with that generated from the excavating bit. Frequency band in the seismic source is as narrow as nearly a single frequency ...

1997-05-27

500

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

Science.gov (United States)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. Supported by National Natural Science Foundation of China (10475112), Western Light Foundation of Chinese Academy of Sciences of ...

2008-05-01