During unit wise conditioning of unit 8, the vacuum started deteriorating inside the tube after a spark. The RGA reading was taken and it was found out that residual gas inside tube was sulphur hexafluoride. A leak was detected in second tube of unit number eight in between electrode 6 to 8. Leak was sealed with the sealant. Again leak check was done and no leak was found. The tank was closed and conditioning was started again. During the same unit number eight conditioning, leak developed again followed by a spark. So the damaged tube was replaced with a new accelerator tube. During the installation time the alignment of the machine was taken care. Again leak checking was done and the tube was baked properly. The tank was closed again and this particular unit was conditioned for about four days. The ...
Although the Federal Facility Agreement (FFA) addresses the entire Oak Ridge Reservation, specific requirements are set forth for the liquid low-level radioactive waste (LLLW) storage tanks and their associated piping and equipment, tank systems, at ORNL. The stated objected of the FFA as it relates to these tank systems is to ensure that structural integrity, containment and detection of releases, and source control are maintained pending final remedial action at the site. The FFA requires that leaking LLLW tank systems be immediately removed from service. It also requires the LLLW tank systems that do not meet the design and performance requirements established for secondary containment and leakdetection be either upgraded or replaced. The FFA establishes a procedural framework for implementing ...
Purpose: To permit accurate detection of sodium leakage by distinguishing between variations in the overflow tank level due to changes in sodium temperature accompanying changes in the power level or operating state of a liquid metal sodium cooled fast breeder, and a reduction in power level due to duct leakage. Constitution: The volume of sodium in the primary cooling system is roughly estimated from the temperatures of hot and cold legs, and the duct leak preset level with respect to the sodium liquid level within an overflow tank when the plant is normal is varied according to the state of the plant. More particularly, the volume of sodium within the overflow tank is calculated on the basis of a signal representing the liquid level detected by a liquid level gauge in the overflow tank and a signal representing the temperature ...
The T Plant facilities in the 200-West Area of the Hanford site were constructed in the early 1940s to produce nuclear materials in support of national defense activities. T Plant includes the 271-T facility, the 221-T facility, and several support facilities (eg, 2706-T), utilities, and tanks/piping systems. T Plant has been recommended as the primary interim decontamination facility for the Hanford site. Project W-259 will provide capital upgrades to the T Plant facilities to comply with Federal and State of Washington environmental regulations for secondary containment and leakdetection. This document provides an advanced conceptual design concept that complies with functional requirements for the T Plant Secondary Containment and LeakDetection upgrades.
The W-259 project will provide upgrades to the 2706-T/TA Facility to comply with Federal and State of Washington environmental regulations for secondary containment and leakdetection. The project provides decontamination activities supporting the environmental restoration mission and waste management operations on the Hanford Site.
This report describes a study to evaluate methods for locating leaks of dielectric fluid from buried high-voltage cable systems. Two primary types of leak location systems were investigated: (1) systems that will rapidly isolate the leak within a manhole section, typically 1000-m long on a feeder that might be 30-km long; and (2) systems that will then pinpoint the location of the leak. Rapid leak isolation was accomplished by developing an enhanced conductivity oil probe which allows the injection of a small quantity of conductive oil and which indicates the path of the oil as it drifts downstream in the direction of the leak. Two methods for pinpointing the leak were proven. The more successful method was the use of trained leak location dogs which were found to have far better sensitivity than instruments and which ...
It is estimated that more than 180.000 kilometres of onshore pipelines will be installed between now and 2012. According to the US Federal Office of Pipeline Safety report (1968-97), the average pipeline suffers one leak per year every 400 miles. This equates to a total of 180 expected leaks per year for a new pipeline alone. Sensornet's continuous real-time Digital LeakDetection monitoring solution has the reach, precision and the speed to provide complete, continuous real-time knowledge (author)
Carbon steel is frequently used to construct concentrated sulphuric acid storage tanks. This paper discussed the corrosion performance of carbon steel tanks and outlined the underlying mechanisms responsible for major corrosion modes. Analyses of hydrogen grooving and dilute acid corrosion failure mechanisms were presented. Recent corrosion-induced leak failures were also discussed. The use of anodic protection and organic coatings as a corrosion control measure was also evaluated. The results of laboratory studies that were conducted to understand corrosion-induced failures showed that carbon steel electrodes exhibited transpassive corrosion at relatively high anodic potentials, while stainless steel electrodes exhibited transpassive corrosion at anodic potentials less than 1 V. It was concluded that corrosion-induced leaks can be prevented by using anodic protection and baked phenolic coating ...
Throughout the DOE complex there are numerous facilities that handle hazardous and radioactive waste solutions. Due to the hazardous constituents of the mixed waste, secondary containment of tank systems and their ancillary piping, in accordance with Resource Conservation and Recovery Act, is a concern for such existing facilities. The Idaho Division of Environmental Quality was petitioned in 1990 for an Equivalent Device determination regarding secondary containment of waste lines embedded in interior concrete walls. The petition was granted; however, it expires in 1996. To address the secondary containment issue, additional studies were undertaken. One study verified the hypothesis that an interior wall pipe leak would follow the path of least resistance through the naturally occurring void found below a rigidly supported pipe and pass into an adjacent room where detection could occur, before any significant deterioration ...
Waste tank W-12 is a tank in the ORNL Low-Level Liquid Waste (LLLW) system that collected waste from Building 3525. Because of a leaking flange in the discharge line from W-12 to the evaporator service tank (W-22) and continual inleakage into the tank from an unknown source, W-12 was removed from service to comply with the Federal Facilities Agreement requirement. The initial response was to decontaminate the valve pit between tank W-12 and the evaporator service tank (W-22) to determine if personnel could enter the pit to attempt repair of the leaking flange. Preventing the spread of radioactive contamination from the pit to the environment and to other waste systems was of concern during the decontamination. The drain in the pit goes to the process waste system; therefore, if high-level liquid waste were generated ...
Six safety initiatives have been identified for accelerating the resolution of waste tank safety issues and closure of unreviewed safety questions. Safety Initiative 5 is to reduce safety and environmental risk from tankleaks. Item d of Safety Initiative 5 is to complete corrosion studies of single-shell tanks to determine failure mechanisms and corrosion control options to minimize further degradation by June 1994. This report has been prepared to fulfill Safety Initiative 5, Item d. The corrosion mechanisms that apply to Hanford Site single-shell tanks are stress corrosion cracking, pitting/crevice corrosion, uniform corrosion, hydrogen embrittlement, and microbiologically influenced corrosion. The corrosion data relevant to the single-shell tanks dates back three decades, when results were obtained from in-situ corrosion coupons in a few single-shell ...
Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leakdetection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed ...
This paper presents a unique method, currently under evaluation, that can continuously track pipeline operation providing essentially instantaneous responses to leaks or ruptures without causing a pressure drop or energy loss. Using the highly linear characteristics of a very accurate and repeatable meter and then correlating it to a second identical unit, a dynamic leakdetection system is planned that can be retrofitted on existing pipelines without a major construction effort nor destroying the integrity of the existing transmission line. Initial tests performed on a crude oil transmission line verified the equipment's performance and established that the repeatability limits are sufficient to continue development of the concept.
Through a comprehensive and aggressive research program Consolidated Edison Company of New York, Inc. (Con Edison) has designed, developed, and installed several new products to address the environmental impact of dielectric fluid from pipe-type cable systems. These include: On Line LeakDetection, Leak Location, Retractable Flow Direction Indicator, Full Stop Joints, and Transition Joints. This paper describes the application of the aforementioned products on the Con Edison underground transmission system.
Recent advances in elastic-plastic fracture mechanics have made it possible to assess the stability of cracks in ductile piping systems. These technological developments have been used by Ontario Hydro as the nucleus of an approach for demonstrating that CANDU primary heat transport piping systems will not break catastrophically; at worst they would leak at a detectable rate. This leak-before-break approach has been taken on the Darlington nuclear generating station as a design stage alternative to the provision of pipe whip restraints on large diameter, primary heat transport system piping. Positive conclusions reached via this approach are considered sufficient to exclude the requirement to provide protective devices, such as pipe whip restraints. In arriving at the proposed leak-before-break approach a review of current and proposed leak-before-break licensing positions of other ...
Pipeline leakdetection technologies can be classified according to their specificity, such as their application to offshore or onshore installations or to multi-phase or single-phase flow regimes. They can also be classified according to the technology on which they are based. Available technologies can be categorized into the following 4 groups: (1) compensated mass balance, solving steady state equations which model a specific pipeline, known as real time mode (RTM), (2) the same as group 1, but solving transient equations, known as real time transient model (RTTM), (3) pressure wave behavior, and (4) statistical modeling. Hybrids schemes can also be found. Effective leakdetection systems are needed to address the increasing transformation of very large crude cargo (VLCC) ships into floating production, storage and offloading (FPSO) systems. These operations make use of short and large diameters ...
A scheme is presented for the generation of entangled states for two cavity mirrors. In the scheme each mirror initially in a vacuum state interacts with a weak coherent field, resulting in a photon-number dependent kick. The detection of a photon leaking from the cavities collapses the two mirrors to an entangled state.
This spring, Newfoundland will send off a floating production, storage and offloading (FPSO) vessel to the offshore Terra Nova field. The Terra Nova will proceed southeast through Bull Arm, then northeast out of Trinity Bay, then heads southeast to the Jeanne d'Arc Basin on the Grand Banks. The Terra Nova is expected to produce 115,000 barrels of oil per day for six years, when it reaches full capacity. The consortium, headed by Petro-Canada as senior ownership partner and operator, built an environment protection program into every aspect of the project. Some of the features of the environment protection program include glory holes excavated on the ocean floor for the protection of production equipment from icebergs, to a flare stack on the platform, which has four legs to provide stability in rough seas. The FPSO was designed to withstand sea ice, icebergs, and severe winter storms. Flow lines are also protected, and in the event that a line is damaged, sea water will ...
Leak-before-break (LBB) analyses for circumferentially cracked pipes are currently being conducted in the nuclear industry to justify elimination of pipe whip restraints and jet impingement shields which are present because of the expected dynamic effects from pipe rupture. The application of the LBB methodology frequently requires calculation of leak rates. These leak rates depend on the crack-opening area of a through-wall crack in the pipe. In addition to LBB analyses, which assume a hypothetical flaw size, there is also interest in the integrity of actual leaking cracks corresponding to current leakage detection requirements in NRC Regulatory Guide 1.45, or for assessing temporary repair of Class 2 and 3 pipes that have leaks as are being evaluated in ASME Section 11. This study was requested by the NRC to review, evaluate, and refine current analytical ...
Encapsulation of a unique isotopic blend of krypton and xenon gas employs a special application of laser technology. The encapsulated gas is then used as the primary medium for detection and identification of failed nuclear fuel rods. The use of gas tagging as a means of detecting and identifying failed nuclear fuel rods has been successfully demonstrated and used by the Argonne National Laboratory, Experimental Breeder Reactor (EBR-2) Project, and the Westinghouse Hanford Company (WHC), Fast Flux Test Facility (FFTF) Fast Breeder Reactor Program. The Power Reactor and Nuclear Fuel Development Corporation (PNC) of Japan has selected this leakdetection system for use in their MONJU Prototype Reactor fuel assemblies. The MONJU reactor is almost identical in design to the highly successful FFTF reactor, which is currently in standby status.
A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)
It is imperative to use a leak-proof container for counting liquid sample to prevent contamination of costly gamma detectors. A sealant that ensures no leak is reported. It is a vinyl adhesive sealant used for household purposes, marketed by Gloucester Co., Inc, Franklin, MA under the trade name of Phenoseal (translucent variety). This sealant was superior to other sealants studied because it cures quickly, peels off easily after counting, and contains no detectable radioactivity. This sealant has been thoroughly tested and successfully employed it in the routine analysis of environmental liquid samples. (author)
This paper presents the experience faced by people who works in PETROBRAS Business Unit (UN-RNCE), located in Rio Grande do Norte Province, Brazil, during the implementation of a pipeline leakdetection system. That application involved nine multiphase oil pipelines distributed along several production facilities. Because of the emergency after the leakage that polluted the Guanabara bay and due to the two phases and multi phases pipelines characteristics, the UN-RNCE decided to apply the Pressure Point Analysis (PPA) technology in order to detect leakages. It is a statistical method for leakdetection e uses a very simple instrumentation which facilitates the installation and maintenance. However, in order to get the best performance of the system, it is necessary to know thoroughly the whole process and have a fast and reliable SCADA system for long distance communication. Finally ...
The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO{sub 2} gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsung Units 2, 3, 4, a series of leakdetection ...
With an objective to detect gas leaking from an underground gas pipeline, discussions have been given on a method which utilizes acoustic characteristics of leakage. On leaking sound generated from damaged portions, the form of damaging was hypothesized as pinholes, and spectra of leaking sounds from holes with different diameters were measured. The dominant frequency decreases as the hole diameter increases, while it is in a region of relatively high frequency of 1 kHz or higher. However, detection from the ground surface was impossible when cover soil has thickness from 0.5 to 1.5 m. In an experiment to measure leaking sound inside the pipe, pressure in the pipe was adjusted to 0.02 atm which is a standard pressure for a low-pressure pipe, and the sound was measured when the hole diameters were varied. In any of the results obtained by varying the hole ...
In allusion to the explosion of a urea reactor took place in a fertilizer plant at Pingyin, Shandong, China, a series of evidence collection and inspection jobs which includes collecting operation condition and parameters, sampling the explosion fracture, reactor body apart from explosion fracture, and leakdetection medium and its hangover, etc., had been carried out firstly. Based on these jobs, farther analysis and computation work has been done to the structural and materials characteristics and the operation condition of the urea reactor, including compositions, metallographic phases, tensile properties, impact energy, strain ageing characteristics, and fracture toughness of the urea reactor steels, the compositions of leakdetection medium and its hangover in the urea reactor, and ex...
The transfer of fish from field to laboratory facilities or their propagation in closed or restricted systems frequently results in bacterial infection and ultimately large-scale mortality. In attemps to alleviate this problem, we have added tetracycline hydrochloride to the water prophylactically (pretreating tanks before wild fish were added) and therapeutically (treating tanks after bacterial outbreaks were detected.) In the present study, we examined the effect of tetracyline hydrochloride on the critical thermal maximum (CTM) of the common shiner (Notropis cornutus).
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible ...
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, ...
Piping systems transporting high-pressure fluid will release a large amount of energy, leading to whipping of the broken pipe as well as impingement of the ejecting fluids on adjacent structures if they fracture unstably. Postulation of such an event in design of piping systems in nuclear power plants often requires various counter measures such as installation of pipe whip restraints or jet impingement shields to prevent such damage. One of the approaches to justify exclusion of unstable fracture from the design conditions is leak-before-break (LBB) analysis. In order to demonstrate LBB behavior, it is necessary to prove that in the presence of a part-through wall flaw in the pipe, this flaw will not grow through the wall under fatigue loading and is stable (level 2 LBB) and that the leak of fluid through the penetration is detected by leakdetection systems before unstable ...
Prepared to make housing project managers, maintenance engineering staff, and designers and architects of HUD - assisted and HUD - insured housing projects and mobile home parks aware of their responsibilities under the Natural Gas Pipeline Safety Act, this handbook provides technical guidance for the reduction of gas leaks and the handling of gas leak incidents in residential areas. The hazards of natural gas, concern over gas safety in residential areas, applicable codes and standards, and sources of information and help are reviewed, along with maintenance and engineering considerations relating to gas pipe failures, the detection of gas leaks, appliance servicing, and pipe installation, repair, and replacement. Housing management considerations are also examined, with attention to recordkeeping and reporting, emergency contingency planning, tenant education, staff qualifications and training, and ...
For the expansion to 2.0 MTPY of the CVG Bauxilum alumina plant, the area of clarification and red mud washing was rearranged from four 2-thickener-5-washer trains to two 1-thickener-7-washer trains. As a result of this modification, the specific mud handling capacity of the existing tanks should be increased by almost 3-times. The time allowed for control actions was then significantly reduced, leading to the need of an on-line level detection system, in order to achieve a better and faster control of the operation. With this scope, it was developed and installed a new continuous mud level detector that gives the measurement of both mud and turbid zone levels in the tanks. The development of the new instrument started with an existing instrument for density measurements which was completely re-engineered in order to obtain the maximum readability in the densities founded along the full range of the ...
... Deepwater Horizon leak in the Gulf of Mexico, the Haitian earthquake and subsequent response, release of information by WikiLeaks, the Icelandic ...
In the quest to understand the ultimate nature of WIMPs, we propose the use of a hybrid detection technique: cylinders filled with liquefied noble gasses, acting as targets, are immersed inside a tank of Gd-doped ultra-pure water that provides an active and efficient veto against neutrons. The evaluation of the background rejection capabilities and physics potential of this instrument have been carried out through a full GEANT4 simulation, assuming the detector will be located at the Canfranc underground laboratory (in the Spanish Pyrenees). Our results compare very favourably with existing or planned experiments in the field. This technique is scalable and will allow to reach target masses of few tonnes in the next future.
The defects localization in power cables follows several steps: identification, pre-localization and precise localization. Pre-localization methods, other than echo-metry, are presented first: bridge methods, particular case of low voltage networks, future perspectives. Then, the precise localization methods are described: magneto-acoustic method, audible frequencies method. The particular case of underwater and high-voltage cables is considered too (oil and gas leaksdetection). (J.S.)
A study has been conducted on the statistics of detected neutrons that leaked from four subcritical reflected, enriched-uranium assemblies, to explore the feasibility of developing a criticality warning system based on neutron noise analysis. Studies were conducted on three possible discriminators, i.e., three signatures that might be used to discriminate among assemblies of various multiplications. The noise analysis techniques studied performed well enough in deeply subcritical situations to deserve testing in an applications environment. They have a good chance of detecting changes in reactivity that are potentially dangerous. One can expect sharpest results when doing comparisons, i.e., when comparing two records, one taken in the past under circumstances known to be normal and one taken now to search for change.
Hepatobiliary scintigraphy is the only non-invasive technique providing real-time assessment of hepatocytes function and bile progression from the liver to the intestine; for this reason it is of great importance in the study of jaundice and many other disorders of the liver and the biliary tract in children. Ultrasonography is the initial method of evaluating the intra- and extrahepatic bile ducts dilatation: the differential diagnosis between biliary atresia and neonatal hepatitis cannot however be done without hepatobiliary scintigraphy. Cystic fibrosis patients also require hepatobiliary scintigraphy; liver and biliary tract disease can really occur independently of the underlying disease severity and the presence of steatorrhoea. Hepatobiliary imaging in children who have undergone liver transplantation is of major importance; it can assess vascularity, parenchymal function biliary drainage, possible presence of a bile leak and obstruction; it has very good ...
Nomographs are presented that estimate the evaporation loss from external floating-roof tanks using tank diameter, type of seal, product vapor pressure, and wind velocity.
Waste Management Area U (WMA U) includes the U Tank Farm, is currently regulated under RCRA interim-status regulations, and is scheduled for closure probably post-2030. Groundwater monitoring has been under an evaluation program that compared general contaminant indicator parameters from downgradient wells to background values established from upgradient wells. One of the indicator parameters, specific conductance, exceeded its background value in one downgradient well triggering a change from detection monitoring to a groundwater quality assessment program. The objective of the first phase of this assessment program is to determine whether the increased concentrations of nitrate and chromium in groundwater are from WMA U or from an upgradient source. Based on the results of the first determination, if WMA U is not the source of contamination, then the site will revert to detection monitoring. If WMA U is the source, then a ...
ambassador in Mexico, Carlos Pascual, does he still have your confidence after the WikiLeaks scandals? (In Spanish.) SECRETARY CLINTON: Well, I deeply regret the WikiLeaks...
This inspection plan is written to meet the requirements of WAC 173-303 for operations of a TSD facility. Owners/operators of TSD facilities are required to inspection their facility and active waste management units to prevent and/or detect malfunctions, discharges and other conditions potentially hazardous to human health and the environment. A written plan detailing these inspection efforts must be maintained at the facility in accordance with Washington Administrative Code (WAC), Chapter 173-303, ``Dangerous Waste Regulations`` (WAC 173-303), a written inspection plan is required for the operation of a treatment, storage and disposal (TSD) facility and individual TSD units. B Plant is a permitted TSD facility currently operating under interim status with an approved Part A Permit. Various operational systems and locations within or under the control of B Plant have been permitted for waste management activities. Included are the following TSD units: Cell 4 ...
The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).
The paper-insulated low-pressure oil-filled cable invented in 1917 has been used throughout the world as the major cable system for voltages from 33kV to 525kV and experimentally to 1100kV. The proven reliability of the design is amply demonstrated by the cables installed in the early 1930s still currently in service. The inherent design of an oil-filled cable requires that the low viscosity oil is retained within a lead or aluminium sheath. Changes in oil volume due to changes in ambient temperature and load are accommodated by oil reservoirs which maintain the cable oil pressure within design limits. A microprocessor monitoring system that allows early detection and quick location of oil leaks from high voltage oil-filled cables is described.
This paper describes recent measurements of the subcritical neutron multiplication factor using the /sup 252/Cf source-driven neutron noise analysis method. This work was supported by a program of collaboration between the United States Department of Energy and the Power Reactor and Nuclear Fuel Development Corporation of Japan related to the development of fast breeder technology. The experiment reported consists of a configuration of two interacting tanks of uranyl nitrate aqueous solution with different uranium concentrations in each tank. The /sup 252/Cf-source-driven neutron noise analysis method obtains the subcriticality from the signals of three detectors: the first, a parallel plate ionization chamber with /sup 252/Cf electroplated on one of its plates that is located in or near the system containing the fissile material, and produces an electrical pulse for every spontaneous fission that occurs and thereby serves as a timed source of ...
The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled, fast neutron test reactor located on the Hanford Site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The Fission Gas Monitor System (FGMS) integrates commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows either system A or B to be taken out of service for periodic tests or maintenance without interrupting the overall system performance. A control room color ...
Ophir Corporation was awarded a contract by the U. S. Department of Energy, National Energy Technology Laboratory under the Project Title ''Airborne, Optical Remote Sensing of Methane and Ethane for Natural Gas Pipeline LeakDetection'' on October 14, 2002. This second six-month technical report summarizes the progress made towards defining, designing, and developing the hardware and software segments of the airborne, optical remote methane and ethane sensor. The most challenging task to date has been to identify a vendor capable of designing and developing a light source with the appropriate output wavelength and power. This report will document the work that has been done to identify design requirements, and potential vendors for the light source. Significant progress has also been made in characterizing the amount of light return available from a remote target at various distances from the light source. A ...
The Interim Decay Storage tank (IDS) will be located in a concrete cell in the FFTF reactor building. The tank will have capacity to store 112 driver fuel assemblies and 10 test assemblies in sodium. A criticality safety analysis for the design of the IDS tank was performed. From the analysis, it is concluded that under normal operating conditions and minor abnormal conditions that might shift the fuel, the IDS tank will remain adequately subcritical. (auth)
Most palladium thin film based hydrogen gas sensors have response and recovery times that are too long to make them useful in vehicular and stationary gas leakdetection applications. In contrast, a palladium-silver thin film based microcantilever (MC) hydrogen gas microsensor is reported herein with near ideal response characteristics for use in these hydrogen economy related applications. Specifically, 3-10 second response and recovery times have been measured for these sensors in contrast to previous sensor response measurements of several to tens of minutes using Pd thin film and MC based sensing techniques. The much reduced response times observed in the present study are attributed to a wet chemical Pd-Ag thin film deposition technique and a gas conditioning protocol that produces a highly nanostructured, porous film that rapidly adsorbs and desorbs H2, allowing rapid equilibration with the H2 concentration in the surrounding air. The wet ...
The structural acceptance criteria contained herein for the evaluation of existing underground double-shell waste storage tanks located at the Hanford Site is part of the Life Management/Aging Management Program of the Tank Waste Remediation System. The purpose of the overall life management program is to ensure that confinement of the waste is maintained over the required service life of the tanks. Characterization of the present condition of the tanks, understanding and characterization of potential degradation mechanisms, and development of tank structural acceptance criteria based on previous service and projected use are prerequisites to assessing tank integrity, to projecting the length of tank service, and to developing and applying prudent fixes or repairs. The criteria provided herein summarize the requirements for the analysis and ...
The decontamination of the dissolution tank from spent fuel reprocessing out-ling device is studied, by using FL-AP decontamination agent. The decontamination factor per step is 2.2, 2.4, respectively for #alpha#, #beta# activities. After dissecting the tank, residual contamination in inner surface of the tank was found to be non-uniform. The exact original contamination value of the tank surface could be approximated by calculating the total amounts of radionuclide distributed on the hanging specimens, the dissecting specimen, and radioactive level in waste decontamination agent. Therefore, it can be concluded that the hanging specimens method is feasible for measuring the decontamination factor of spent fuel dissolution tank. (authors)
region, and we think that's a win-win for all of us. MODERATOR: I want to talk about WikiLeaks. Do you think that WikiLeaks has contributed to the decline of American influence in...
Apr 25, 2010... oil per day were leaking from an oil well in the Gulf of Mexico in late April, following an explosion at an offshore drilling rig on April 20, 2010. ...
... sensitive and classified US Government information, a notable recent example being the unlawful release of classified US documents by WikiLeaks ...
This paper discusses the remote plugging of leaks in inaccessible pipework, with main reference to small leaks which frequently appear in ancillary cooling water circuits of nuclear reactors. Initially developed to cure problems of the pre-stressed concrete pressure vessels of UK reactors, the ZORIC sealant has been used to repair leaking biological shield pipework on six CANDU reactors. ZORIC is based on a water-soluble epoxy resin and an aqueous suspension of a refined mineral clay. This paper describes the evolution of the sealant, the qualification and testing program, and their application to CANDU reactor systems. 2 refs., 6 figs.
The approach estimating the leak probability of flanged joint due to the destruction of fastening studs is described. The mentioned approach consists of two stages. The probability of destroying one stud is calculated at the first stage, and the probability of different combination interpositions of intact and destroyed studs is calculated at the second one. The probability calculation of leak in the area of collector cover of steam generator PGV-1000 is used as an example of developed approach
Radionuclide techniques have commonly been used to assess ventriculovenous shunt function, cerebrospinal fluid dynamics, and for the diagnosis of cerebrospinal fluid leaks. All of these techniques were utilized in this unusual case of retrograde migration of a ventriculoatrial catheter into the neck, with cutaneous fistulization and CSF leak. (orig.).
A new method of pinpointing dielectric fluid leaks on pipe-type and self-contained cables using perfluorocarbon tracer (PFT) is presented. The method has successfully been used on the Con Edison transmission system to locate leaks of dielectric fluid on both types of cables. Application of the PFT technique does not require feeder deenergization and provides major advantages over the conventional method of freeze and pressure testing. Description of the method and results of field application are presented in the paper.
Wolsung nuclear power plant has experienced four occasions of reactor shutdown owing to heavy water leaks since its commercial operation. Among these heavy water leaks, only one case was acute and brought about reactor shutdown but the other cases listed below were chronic and repaired after manual reactor shutdown. (author). 4 tabs., 10 figs.
The Nuclear Safety Commission acknowledged the policy of the Agency of Natural Resources and Energy to cope with these important matters on August 8, 1984. The main contents of the investigation and deliberation were as follows, As to the prevention of the occurrence of fires, the prevention of the leak and spread of inflammable liquid and gas, the installation of protective relays and so on, the use of incombustible materials and aseismatic design and the installation of lightning arresters. As to the detection of fires and fire fighting, the proper selection and arrangement of fire detectors and extinguishers, the extinguishers which do not harm the safety function of structures and equipment, and the extinguishers which are not affected by natural phenomena. As to the reduction of the effect of fires, the proper installation of fire walls and extinguishers, and the high temperature shut off of nuclear reactors which is never hampered by any ...
Drums is an acronym for Dynamic Rating and Underground Monitoring System, with specific application to high-pressure pipe-type cable systems which are the predominant means of underground electric power transmission in the United States. The primary objective of this EPRI-sponsored feasibility study was to establish the technical feasibility of seven DRUMS functions and two novel DRUMS communication schemes. The seven DRUMS functions which monitor the system's vital and measurable parameters in real time and perform system diagnostics in the event of component deterioration, malfunction or failure are: Real Time Current Monitoring and Rating; LeakDetection and Location; Fault Location; Pothead Monitoring; Oil Monitoring; Pipe Protection; and Splice Monitoring. The two DRUMS communication schemes are internal to the pipe cable system. Mechanical Communication will use pressure pulses to transmit data along the system, while the ...
A new type of ionization chamber with levitated electrode has been developed. In this ionization chamber, an ion-collection electrode levitates in the air without getting any physical support from the insulator. The electrode is charged by an electrostatic charger without physical contact. The charge of the electrode is read out at a Faraday cage periodically at a given time interval without physical contact. Because its electrode levitates, the ionization chamber produces no background current caused by leaks or piezo current. In addition, as the charging of its electrode and the read-out of its charge are carried out without physical contact, no irregular charge or contact potential difference due to the chattering between electrode and contact point occurs. Through experiments, it was found that this ionization chamber was able to measure the {gamma}-ray dose such as the environmental radiation with a high degree of sensitivity. The minimum ...
A geothermal heat pump (GHP) system with three ground coils was installed in a residence in northern Idaho with a portion of the ground heat exchanger wrapped around the residential septic tank. The septic coil provided a significant portion of the heating for the residence over the heating season. There was no evidence of the septic tank freezing up or failing to properly function. Utilizing a septic tank as a heat source for GHP systems is feasible design option if the septic tank is used on a full-time basis. However, the tank should be surrounded on all sides by a large amount of soil and/or insulated from the ground surface to ensure that ground temperatures near the tank remain warm during the winter.
Abstract: The Hanford Tanks Initiative (HTI) is a five-year project resulting from the technical and financial partnership of the U.S. Department of Energy`s Office of Waste Management (EM-30) and Office of Science and Technology Development (EM-50). The HTI project accelerates activities to gain key technical, cost performance, and regulatory information on two high-level waste tanks. The HTI will provide a basis for design and regulatory decisions affecting the remainder of the Tank Waste Remediation System`s tank waste retrieval Program.
Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface probes. Two-dimensional ...
Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface probes. Two-dimensional ...
The US DOE manages the safe storage of approximately 650,000 tons of depleted uranium hexafluoride remaining from the Cold War. This slightly radioactive, but chemically active, material is contained in more than 46,000 steel storage cylinders that are located at Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Some of the cylinders are more than 40 years old, and approximately 17,500 are considered problem cylinders because their physical integrity is questionable. These cylinders require an annual visual inspection. The remainder of the 46,000-plus cylinders must be visually inspected every four years. Currently, the cylinder inspection program is extremely labor intensive. Because these inspections are accomplished visually, they may not be effective in the early detection of leaking cylinders. The inspection program requires approximately 12--14 full-time-equivalent (FTE) employees. At the cost of approximately $125K per FTE, ...
An average of 9 million gallons per day of oil-contaminated ballast water off loaded from tankers are treated at the Alyeska Pipeline Service Company Ballast Water Treatment Facility at the terminus of the Trans-Alaska Pipeline in Port Valdez, Alaska. This paper focuses on the results of 2 Prince William Sound Regional Citizens' Advisory Council monitoring programs which detail changes in the chemical composition of treated ballast water as it moves from tankers through the facility and subsequently traces the effluent hydrocarbons into the receiving environment of Port Valdez. The treatment facility involves gravity separation tanks, dissolved air flotation cells and biological treatment tanks. Effluent containing traces of volatile aromatics, including benzene, toluene, ethylbenzene and xylenes, low levels of oil, saturated hydrocarbons and polycyclic aromatic hydrocarbons is being continuously discharged to Port Valdez. Because of ...
Liquid Zone Control (LZC) System is a 'first-of-its-kind' reactivity control device, designed and implemented at TAPP-3 and 4. The system provides zonal and bulk power control. The system consists of fourteen Zone Control Compartments (ZCCs) containing demineralised light water as neutron absorber. Reactivity control is achieved by varying the level of water in the compartments bi-directionally. Six in-core zircaloy assemblies, housing the fourteen ZCCs and an elaborate process system constitute the LZC system. Measurement of water levels in the ZCCs is done using helium bubbler method. Reliability of ZCC water level measurement is of paramount importance. Commissioning and operating the new system trouble free was a challenge, considering the complex nature of the system. While commissioning the system, level measurement of one of the ZCCs (ZCC - 1) was found erratic and inconsistent. Methodologies were developed to identify the problem and investigations revealed leakage of helium ...
The US Department of Energy (DOE) has millions of gallons of high level nuclear waste stored in underground tanks at Hanford, Washington and Savannah River, South Carolina. These tanks will eventually be emptied and decommissioned. This will leave a residue of sludge adhering to the interior tank surfaces that may contaminate nearby groundwaters with radionuclides and RCRA metals. Performance assessment (PA) calculations must be carried out prior to closing the tanks. This requires developing radionuclide release models from the sludges so that the PA calculations can be based on credible source terms. These efforts continued to be hindered by uncertainties regarding the actual nature of the tank contents and the distribution of radionuclides among the various phases. In particular, it is of vital importance to know what radionuclides are associated with solid sludge components. ...
Before low-level waste may be disposed of, a performance assessment must be written and then approved by the DOE (DOE 1988a DOE 1999a). The performance assessment is to determine whether ''reasonable assurance'' exists that the performance objectives of the disposal facility will be met. The DOE requirements for waste disposal (DOE 1988a DOE 1999a) require the protection of public health and safety; and the protection of the environment. Although quantitative limits are sometimes stated (for example, the all-pathways exposure limit is 25 mrem/year), usually the requirements are stated in a general nature. Quantitative limits were established by: investigating all potentially applicable regulations as well as interpretations of the review panels which DOE has established to review performance assessments, interacting with program management to establish the additional requirements of the program, and interacting with the public (i.e., the Hanford ...
The US Department of Energy (DOE) has millions of gallons of high level nuclear waste stored in underground tanks at Hanford, Washington and Savannah River, South Carolina. These tanks will eventually be emptied and decommissioned. This will leave a residue of sludge adhering to the interior tank surfaces that may contaminate groundwaters with radionuclides and RCRA metals. Experimentation on such sludges is both dangerous and prohibitively expensive so there is a great advantage to developing artificial sludges. The US DOE Environmental Management Science Program (EMSP) has funded a program to investigate the feasibility of developing such materials. The following text reports on the success of this program, and suggests that much of the radioisotope inventory left in a tank will not move out into the surrounding environment. Ultimately, such studies may play a significant role in developing safe and ...
The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.
The Idaho Nuclear Technology and Engineering Center (INTEC) was home to nuclear fuel reprocessing activities for decades at the Idaho National Engineering and Environmental Laboratory. As a result of the reprocessing activities, INTEC has accumulated approximately one million gallons of acidic, radioactive, sodium-bearing waste (SBW). The purpose of this demonstration was to investigate a reforming technology, offered by THORsm Treatment Technologies, LLC, for treatment of SBW into a "road ready" waste form that would meet the waste acceptance criteria for the Waste Isolation Pilot Plant (WIPP). A non-radioactive simulated SBW was used based on the known composition of waste tank WM-180 at INTEC. Rhenium was included as a non-radioactive surrogate for technetium. Data was collected to determine the nature and characteristics of the product, the operability of the technology, the composition of the off-gases, and the fate of key radionuclides (cesium ...
The Idaho Nuclear Technology and Engineering Center (INTEC) was home to nuclear fuel reprocessing activities for decades at the Idaho National Engineering and Environmental Laboratory. As a result of the reprocessing activities, INTEC has accumulated approximately one million gallons of acidic, radioactive, sodium-bearing waste (SBW). The purpose of this demonstration was to investigate a reforming technology, offered by THORsm Treatment Technologies, LLC, for treatment of SBW into a ''road ready'' waste form that would meet the waste acceptance criteria for the Waste Isolation Pilot Plant (WIPP). A non-radioactive simulated SBW was used based on the known composition of waste tank WM-180 at INTEC. Rhenium was included as a non-radioactive surrogate for technetium. Data was collected to determine the nature and characteristics of the product, the operability of the technology, the composition of the off-gases, and the fate of key ...
Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm water detectiontanks, gates, pumping stations, etc)., the interceptor, the WWTP and the ...
This paper reported on a study in which hydrogen was produced by fermentation of biomass. A continuous process using a non-sterile substrate with a readily available mixed microflora was used on heat treated digested sewage sludge from a wastewater treatment plant. Hydrogen was produced from waste sugar at a pH of 5.2 and a temperature of 37 degrees C. An experimental setup of three 5.5 L working volume continuously stirred tank reactors (CSTR) in different stirring speeds were constructed and operated at 7 different hydraulic retention times (HRTs) and different organic loading rates (OLR). Dissolved organic carbon was examined. The results showed that the stirring speed of 135 rpm had a beneficial effect on hydrogen fermentation. The best performance was obtained in 135 rpm and 8 h of HRT. The amount of gas varied with different OLRs, but could be stabilized on a high level. Methane was not detected when the HRT was less than 16 h. The study ...
Inert gas contamination, structure and mechanical properties of consolidated high-Ni alloy powder material were studied to improve its characteristics. In experiment, the chemical composition and fraction of porosity in cross sections of Alloy 625 powder were examined which was produced by Ar gas atomization method impinging supplemental gas jet onto accumulated alloy powder in the bottom of a tank for rapid cooling. The structure and mechanical properties of the alloy rod were also examined which was produced by hot hydrostatic pressing or hot extrusion of the powder filled into a capsule. As a result, although Ar content included in the powder produced by Ar gas atomization method decreased with reduction in grain size, the fine powder less than 22{mu}m still included Ar of nearly 0.5mass-ppm. Obvious correlation was found between the fraction of porosity in powder cross sections and Ar in the powder. Although cavities were detected in the ...
For location of leakage at district heating pipelines several techniques are available today. If there is no wire bound lead monitoring system installed, the DH company has to apply mobile methods for detection and location and if possible characterization of leakage. Most mobile methods available today are restricted in application and often they cause supply disconnections, especially the location of very small leaks is difficult. The Institute for Environmental, Safety and Energy Technology (UMSICHT) has tested a new developed method that can be executed by own employees of DH companies that can be realised parallel to normal supply mode, and that is able to locate and characterize even very small leakages. (orig.) [Deutsch] Zur Lecksuche an Fernwaermeleitungen stehen verschiedene Techniken zur Verfuegung. Wurde beim Bau der Fernwaermetrasse kein drahtgebundenes Ueberwachungssystem eingebaut, ist der Netzbetreiber auf mobile Lecksuchmethoden ...
This report will be revised upon completion of current testing investigating the radiolytic stability of additional energetic materials and the analysis of tank farm samples for volatile and semi-volatile organic compounds.
Nomographs have been constructed to estimate the average evaporation loss from internal floating-roof tanks. Loss determined from the charts can be used to evaluate the economics of seal conversion and to reconcile refinery, petrochemical plant, and storage terminal losses. The losses represent average standing losses only. They do not cover losses associated with the movement of product into or out of the tank. The average standing evaporation loss from an internal floating-roof tank depends on: vapor pressure of the product; type and condition of roof seal; tank diameter; and type of fixed roof support. The nomographs can estimate evaporation loss for product true vapor pressures (TVP) ranging from 1.5 to 14 psia, the most commonly used seals for average and tight fit conditions, tank diameters ranging from 50 to 250 ft, welded and bolted designs, and both self-supporting and ...
This invention concerns a hydraulic braking system for loads subjected to impacts and vibrations. These double acting telescopic type hydraulic braking systems possess significant drawbacks linked to possibly important hydraulic leaks due to (a) the use of many dynamic seals in such appliances and (b) the effects of the environment of the system on these seals, particularly when employed in nuclear power stations where the seals reach significant temperatures and are subjected to radiation. Under this invention a remedy is suggested to such drawbacks by integrating means to offset automatically the leaks and the accumulation of hydraulic fluid expansions, as well as facilities to show if such leaks have occurred.
Object: To provide a tank, which can safely and reliably accommodate high temperature sodium containing radioactive substance in case of occurrence of an accident in a sodium system and thus prevent spread of contamination. Structure: A sodium drain duct inserted into a tank from above the tank is provided at the position of its lower end with a buffer means for preventing direct flow-down of sodium to a bottom plate. A means for preventing the discharge of radioactive substance to the cover gas is provided above the lower end of the sodium drain tube so as to surround the sodium drain tube. (Kamimura, M.).
PUREX high-level waste (HLW) is contained at the West Valley Demonstration Project (WVDP) in an underground carbon-steel storage tank. The HLW consists of a precipitated sludge and an alkaline supernate. This report describes the system that the WVDP has developed and implemented to resuspend and wash the HLW sludge from the tank. The report discusses Sludge Mobilization and Wash System (SMWS) equipment design, installation, and testing. The storage tank required modifications to accommodate the SMWS. These modifications are discussed as well.
that needs to change is the ambiguity in the laws themselves. QUESTION: The issue of WikiLeaks raised? DEPUTY ASSISTANT SECRETARY BAER: It was not. It was raised by the students....
Vacuum pressure standards of the orifice-flow type require known gas flows of 10/sup -6/ mol/s (10/sup -2/ atm cm/sup 3//s at 0 /sup 0/C) and less. Known gas flows can also be used to calibrate ''standard'' leaks by comparing the pressures generated when flows from the leak and the flowmeter are alternately passed through a constant conductance. Two constant-pressure, piston displacement flowmeters developed at the National Bureau of Standards are described that can generate flows between 10/sup -6/ and 10/sup -10/ mol/s with an estimated uncertainty of 0.8% to 2%. Comparisons of the flowmeters with alternate calibration techniques, and repeated low-range leak and vacuum gauge calibrations, have been used to confirm the estimated uncertainty and random errors of the flowmeter.
Sources of industrial emissions of 1,3-butadiene are discussed both by process (production, consumers) and type (equipment leaks, point sources). Quantification of the emissions are presented, as reported...Full Text Available
for cyber issues? Did you decide to establish this position because of the WikiLeaks incident? DR. SLAUGHTER: No. No, that decision was actually taken nearly a year ago,...
site for reference information. Other recipients include Google's Translator, WikiLeaks, The ICUN Red List of Threatened Species, and the Public Library of Science (PLOS)....
AIM:The study compares the efficiency, side effects and complications of autologous blood pleurodesis with talcum powder and tetracycline.MATERIALS...Full Text Available
This document provides structural load requirements and their basis for maintaining the structural integrity of the Hanford Single-Shell Tanks during waste feed delivery and retrieval activities. The requirements are based on a review of previous requirements and their basis documents as well as load histories with particular emphasis on the proposed lead transfer feed tanks for the privatized vitrification plant.
This document provides data on aerosol concentrations in tank headspaces, total mass of aerosols in the tank headspace, and mass of aerosols sent to the exhauster during rotary mode core sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based upon operational data and non-destructive assay.
This document provides data on aerosol concentrations in tank head spaces, total mass of aerosols in the tank head space and mass of aerosols sent to the exhauster during Rotary Mode Core Sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based on operation data.
The underground storage tanks at the Hanford Complex contain mixed wastes generated over many years from plutonium production and recovery processes. The chemical changes of the organic materials used in the extraction processes and disposed to the tanks have a direct bearing on several specific safety issues, including potential energy releases from these tanks. This paper will give details of a study that is directed towards elucidating thermal and radiological decomposition mechanisms and products of the organic contents of the tanks. The study is being conducted in two parts. The first part, an aging study, will determine kinetics and products of the degradation of a simulated waste subjected to #gamma#-radiation from an external source. Although the simulant will not contain radioactive elements, it will contain other representative inorganic compounds and the primary organic compounds thought to ...
Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the ...
Many electric power utilities are currently employing machine condition monitoring technologies as a means of reducing forced outages and controlling repair costs. These condition monitoring technologies are a set of {open_quotes}tools{close_quotes} to help maintenance and operations personnel identify and repair machinery problems before catastrophic failure occurs. In this way, the analysis of this data becomes a vital link in the daily operation of the plant. Machinery vibration analysis, machinery balancing and alignment, motor current testing, periodic thermography surveys, analysis of lubrication oil samples, performance monitoring, chemistry monitoring, ultrasonic leakdetection surveys, and non-destructive inspections are some of the technologies available to perform this condition monitoring. However, even for a small or medium size plant, the sheer volume of data provided by applying all or some of these technologies can be ...
The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to ...
This report describes the work performed during FY 1995 by Pacific Northwest Laboratory in developing and optimizing analysis techniques for identifying organics present in Hanford waste tanks. The main focus was to provide a means for rapidly obtaining the most useful information concerning the organics present in tank waste, with minimal sample handling and with minimal waste generation. One major focus has been to optimize analytical methods for organic speciation. Select methods, such as atmospheric pressure chemical ionization mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry, were developed to increase the speciation capabilities, while minimizing sample handling. A capillary electrophoresis method was developed to improve separation capabilities while minimizing additional waste generation. In addition, considerable emphasis has been placed on developing a rapid screening tool, based on Raman and ...
Testing was performed to determine the feasibility and processing characteristics of evaporation of actual Defense Waste Processing Facility (DWPF) recycle material. Samples of the Off Gas Condensate Tank (OGCT) and Slurry Mix Evaporator Condensate Tank (SMECT) were transferred from DWPF to the Savannah River National Lab (SRNL) Shielded Cells and blended with De-Ionized (DI) water and a small amount of Slurry Mix Evaporator (SME) product. A total of 3000 mL of this feed was concentrated to approximately 90 mL during a semi-batch evaporation test of approximately 17 hours. One interruption occurred during the run when the feed tube developed a split and was replaced. Samples of the resulting condensate and concentrate were collected and analyzed. The resulting analysis of the condensate was compared to the Waste Acceptance Criteria (WAC) limits for the F/H Effluent Treatment Plant (ETP). Results from the test were compared to previous testing ...
An alkaline-side solvent extraction process was developed for cesium removal from Savannah River Site (SRS) tank waste. The process was invented at Oak Ridge National Laboratory and developed and tested at Argonne National Laboratory using singlestage and multistage tests in a laboratory-scale centrifugal contactor. The dispersion number, hydraulic performance, stage efficiency, and general operability of the process flowsheet were determined. Based on these tests, further solvent development work was done. The final solvent formulation appears to be an excellent candidate for removing cesium from SRS tank waste.
A large amount of radioactive waste has been stored safely at the Savannah River and Hanford sites over the past 46 years. The aim of this report is to review the experimental corrosion studies at Savannah River and Hanford with the intention of identifying the types and rates of corrosion encountered and indicate how these data contribute to tank failure predictions. The compositions of the High-Level Wastes, mild steels used in the construction of the waste tanks and degradation-modes particularly stress corrosion cracking and pitting are discussed. Current concerns at the Hanford Site are highlighted.
An independent chemical compatibility review of various wrapping and absorbent/padding materials was conducted to evaluate resistance to chemicals and constituents present in liquid waste from the Hanford underground tanks. These materials will be used to wrap long-length contaminated equipment when such equipment is removed from the tanks and prepared for transportation and subsequent disposal or storage. The materials studied were Cooley L18KU, Herculite, and Elephant Mat. The study concludes that these materials are appropriate for use in this application.
An anaerobic fermenter-decanter for the purification of residual water from the sugar industry, with recovery of methane, consists of a tank with inclined walls, with a central agitator on a vertical shaft. A flexible cover anchored by its periphery to the walls of the tank and totally submerged forms a collecting pocket for the fermentation gases. The water to be purified is introduced, after being heated to about 35, towards the bottom of the tank near the agitator. A metal collecting bell with submerged edges and with the shaft of the agitator passing axially through it is connected by its edges to a central opening of the cover. The purification yields may exceed 90%.
Presented in this report are the quantitative and qualitative aspects of the more than 5,800 applications of Grafoil on-plant. The subject all-graphite product was originally made by the Union Carbide Corporation. Its utilization in the forms of valve packing, gasketing and sealant tapes for leak repair and prevention on-plant since March 1970 is marked with typical zero-leak results. For all practical purposes, the successful results with Grafoil implementation indicate an unqualified control of leakage problems that began in 1967 with the V-11 and V-12 valves in the primary system of N Reactor. Meaningfully, the accruals of savings with existing and future applications shall continue to be incalculable in personnel exposure, maintenance, and capital. Inherent in the savings are the devised methodology and innovative developments coordinately employed in resolving the leak repair problems.
The loss of seal of the H9 channel in vacuum, freeing the entire cross section of the front part, leads to a fast leak that progresses rapidly. The effect of depressurizing the reflector can leads to shutdown of the shutdown rod pumps. The source changer associated with the channel fills completely before the valve closes. All of the leak water remains contained within the source changer containment. After the valves open, cooling of the fuel element is handled by natural convection, requiring a reversal of the flow between the plates. This changeover, which takes place at a relatively low pressure level, could lead to local boiling in the fuel element. Consequently, irreversible transformations cannot be excluded as possibilities for the fuel element and even for the control rod. Subsequently, the can is refilled with heavy water with establishment of the usual pressure levels.
Recently, the leak-before-break (LBB) concept has been used successfully to eliminate some pipe whip restraints, snubbers and jet impingement shields from the primary reactor cooling system piping of pressurized water reactors. This has resulted in substantial savings in maintenance costs, reductions in radiation exposure of plant service personnel, and has enhanced the overall safety of nuclear power plants. This study provides guidelines to utilities in expanding the application of the LBB concept to additional pipe systems and it couples the concept with hardware optimization. Seven high energy piping systems were investigated for technical feasibility in using the LBB concept. The results indicate that some of these seven lines are good candidates for the leak-before-break application.
Large quantities of organic chemicals used in reprocessing spent nuclear-fuels at the Hanford Site have accumulated in underground high-level radioactive waste tanks. The organic content of these tanks must he known so that the potential for hazardous reactions between organic components and sodium nitrate/nitrite salts in the waste can he evaluated. The solubilities of organic compounds described in this report will help determine if they are present in the solid phases (salt cake and sludges) as well as the liquid phase (interstitial liquor/supernate) in the tanks. The solubilities of five significant sodium salts of carboxylic acids and aminocarboxylic acids [sodium oxalate, formate, citrate, nitrilotriacetate (NTA) and ethylendiaminetetraacetate (EDTA)] were measured in a simulated supernate solution at 25 degrees C, 30 degrees C, 40 degrees C, and 50 degrees C.
This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.
This technical memorandum (TM) documents the 1995 characterization of eight underground radioactive waste tanks at Oak Ridge National Laboratory (ORNL). These tanks belong to the Gunite and Associated Tanks (GAAT) operable unit, and the characterization is part of the ongoing GAAT remedial investigation/feasibility study (RI/FS) process. This TM reports both field observations and analytical results; analytical results are also available from the Oak Ridge Environmental Information System (OREIS) data base under the project name GAAT (PROJ-NAME = GAAT). This characterization effort (Phase II) was a follow-up to the {open_quotes}Phase I{close_quotes} sampling campaign reported in Results of Fall 1994 Sampling of Gunite and Associated Tanks at the Oak Ridge National Laboratory, Oak Ridge, Tennessee, ORNL/ER/Sub/87-99053/74, June 1995. The information contained here should be used in conjunction with that ...
The removal of paraffinic bottom accumulations from refinery storage tanks represents an increasingly costly area of petroleum storage management. Microorganisms can be used to reduce paraffinic bottoms by increasing the solubility of bottom material and by increasing the wax-carrying capacity of carrier oil used in the cleaning process. The economic savings of such treatments are considerable. The process is also intrinsically safer than alternative methods, as it reduces and even eliminates the need for personnel to enter the tank during the cleaning process. Both laboratory and field sample analyses can be used to document changes in tank material during the treatment process. These changes include increases in volatile content and changes in wax distribution. Several case histories illustrating these physical and chemical changes are presented along with the economics of treatment.
This report represents the timetables, responsible organizations, and methods required to comply with the newly promulgated Washington Administrative Code (WAC) 173-360 Underground Storage Tank (UST) Regulations which became effective December 29, 1990. This report only addresses UST systems that contain nonradioactive material. A total of 84 tanks at the Hanford Site are currently regulated under WAC 173-360. In addition, 32 regulated tanks have been removed as a result of the federally mandated program and the newly implemented state regulations. The majority of the USTs at the Hanford Site are operated by Westinghouse Hanford; however, one is operated by Kaiser Engineers Hanford (KEH) and one by Pacific Northwest Laboratory (PNL).
The dynamic response of thin liquid storage tanks to earthquakes is a very complicated phenomenon, because it can be highly non linear. Among others, one can meet material and geometric non linearities of the tank shell leading eventually to static or dynamic buckling non linear behavior of anchor bolts, contact non-linearities due to the uplift of the tank base and to the unilateral character of the fluid pressure on the shell and high amplitude fluid oscillations. Moreover, linear or non linear soil structure interaction affects considerably the response of the fluid structure system under consideration. In this paper we focus attention on problems related only to the base uplift and anchors plastification. We study a tank similar to the Hualien project tank, but we neglect the soil structure interaction. The studied tank is representative of medium height to ...
Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)
Air flow rates and carbon dioxide concentrations of air entering and exiting eight H-Area waste tanks were monitored for a period of one year. The average instanteous concentration of carbon dioxide in air is within the range reported offsite, and therefore is not affect by operation of the coal-fired power plant adjacent to the tank farm. Waste solutions in each of the tanks were observed to be continuously absorbing carbon dioxide. The rate of absorption of carbon dioxide decreased linearly with the pH of the solution. Personnel exposure associated with the routine sampling and analysis of radioactive wastes stored at SRP to determine the levels of corrosion inhibitors in solution could be reduced by monitoring the absorption of carbon dioxide and using the relationship between pH and carbon dioxide absorption to determine the free hydroxide concentration in solution.
Leakage after oesophageal anastomosis or perforation remains a challenge for the surgeon. Traditional management has been operative repair or intensive conservative management. Both treatments are...Full Text Available
especially since your attack several years ago. I was wondering, in the wake of WikiLeaks, what the Estonians can help the U.S. with in terms of developing an - as...
QUESTION: You've already had one trip where you went to deal with fallout from WikiLeaks. You are visiting a couple of places where the leaders were quoted saying some very...
IntroductionPersistent lymphatic drainage following retroperitoneal lymph node dissection for testicular tumor is an uncommon complication.Case presentationWe...Full Text Available
As the IC Information Sharing Executive (IC ISE), my main focus today concerns classified information--and, in particular, information that is derived from intelligence sources and methods, or information that is reflected in the analytic judgments and as...
efforts to work with other countries to solve shared problems. U.S. Condemns Alleged WikiLeaks Disclosures November 29, 2010: President Obama and Secretary of State Hillary Rodham...
During the summer of 2003, a gastroenteritis outbreak spread throughout a holiday resort in central Italy. Fecally contaminated groundwater and seawater were leaking into the non–drinking-water...Full Text Available
The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford Site. The FFTF is the only reactor of this type designed and operated with the intent of meeting the licensing requirements of the Nuclear Regulatory Commission (NRC). Unique characteristics of the FFTF that present special challenges related to leak rate testing include thin wall containment vessel construction, cover gas systems that penetrate containment, and a low-pressure design basis accident. The successful completion in 1986 of the third FFTF Integrated Leak Rate Test (ILRT) five days ahead of schedule and 10% under budget was a major achievement for the Westinghouse Hanford Company. The success of this operational safety test was due in large part to a special local area network (LAN) of three IBM PC/XT computers that monitored the sensor data, calculated the containment vessel leak rate, and displayed test results. The ...
The development and successful application of a unique leak sealant formulation comprised of a mixture of graded, hollow ceramic microspheres, surface oxidized aluminum powder and saturated gibbsite suspension is described. The project was undertaken to address the escalating leakage from up to 15 small weld defects in the water reflector vessel, an integral component of the NRU (National Research Universal) reactor calandria. The reflector surrounds the reactor core with a neutron reflecting blanket of light water. Injection of the sealant is typically done with the reactor shutdown and the water reflector system operating normally, but can also be performed with the reactor at full power. The procedure is simple and effective. Individual treatments of as little as 125 ml of sealant (10 ppm in the 12,500 L system) have yielded leak reductions exceeding 2000 L/day. The accumulated leak reductions of several treatments now ...
The recent online publication of classified defense documents by the organization WikiLeaks and subsequent reporting by the New York Times and other news media have focused attention on whether such publication violates U.S. criminal law. The Attorney Gen...
The recent online publication of classified defense documents and diplomatic cables by the organization WikiLeaks and subsequent reporting by the New York Times and other news media have focused attention on whether such publication violates U.S. criminal...
AIM: To compare 2 different types of covered esophageal nitinol stents (Ultraflex and Choostent) in terms of efficacy, complications, and long-term outcome.METHODS: A retrospective review of...Full Text Available
Feb 11, 1983 ... Kenmore cooktop stove, three. Saxophone, used only two years,. Executive wood desk, 36" x 72", minutes to NASA, $435/me. plus wagon, ...
This paper proposes a self-optimized coverage coordination scheme for two-tier femtocell networks, in which a femtocell base station adjusts the transmit power based on the statistics of the signal and the interference power that is measured at a femtocell downlink. Furthermore, an analytic expression is derived for the coverage leakage probability that a femtocell coverage area leaks into an outdoor macrocell. The coverage analysis is verified by simulation, which shows that the proposed scheme provides sufficient indoor femtocell coverage and that the femtocell coverage does not leak into an outdoor macrocell.
Eight years ago, corrosion and tube denting seriously threatened the reliability and design life of steam generators, especially for closed loop arrangements in pressurized water reactors (PWRs). Concentrated research by the Steam Generator Owners Group (SGOG) diagnosed the causes and produced effective solutions, notably guidelines for water chemistry control in the secondary loop. The guidelines recommend specific levels of water impurities and remedial actions to prevent cooling-water leaks in the condenser, prevent air leaks, limit corrosion product buildup, and remove some impurities while neutralizing others. Continued research in SGOB-II is investigating intergranular corrosion and stress corrosion cracking. 3 figures.
Eight years ago, corrosion and tube denting seriously threatened the reliability and design life of steam generators, especially for closed loop arrangements in pressurized water reactors (PWRs). Concentrated research by the Steam Generator Owners Group (SGOG) diagnosed the causes and produced effective solutions, notably guidelines for water chemistry control in the secondary loop. The guidelines recommend specific levels of water impurities and remedial actions to prevent cooling-water leaks in the condenser, prevent air leaks, limit corrosion product buildup, and remove some impurities while neutralizing others. Continued research in SGOB-II is investigating intergranular corrosion and stress corrosion cracking. 3 figures.
Steam generator tube denting is primarily caused by build-up of corrosion products at the tubesheet and the tube support plates. The mechanism of dent growth and the identification of tubes which should be removed from service have been studied. The practical outcome has been to prevent in-service tube leaks and to avoid unnecessary plugging of large numbers of tubes. A finite element study of tubesheet deformation (of pulled leaking tubes from reactors) was undertaken. Profilometry results for characterizing dents are given. Although several modifications have been made the high resolution profilometry system performance and the results obtained have proved satisfactory. (U.K.).
To reduce the radiation dose that accumulated on the reactor coolant pump, decontamination work was carried out at the Maanshan Nuclear Power Plant. A four-step alkaline permanganate (AP)-CanDecon process was applied to remove the activity on the turning vane diffuser and pump impeller. The first step consisted of 8 h of AP treatment and 7 h of decontamination. It was followed by 2.5 h of AP treatment and 5 h of decontamination. An average decontamination factor of 2.9 was obtained. To understand the corrosion of the decontaminating reagents on the materials, coupons were installed in the decontamination tank. These were as-received and sensitized 304SS, alloy 600, casting stainless steel (CF-8), stellite-6, and carbon steels (A508 and A533). The exposure rates (mR h"-"1) of the carbon steels were approximately five times higher in magnitude than those of the other materials. The decontamination levels (dpm per 100 cm"2) of the A508 and A533 carbon steels were 5432 ...
A critical review of the literature revealed no experiments on uranyl ion transfer from an aqueous to a tributyl phosphate phase which positively measured the kinetics of the chemical reaction at the interphase. Drawing isorhythmic lines on a three component diagram gives a complex correlation for the compaction of three sizes of glass beads. Neither the use of thoria sols nor high feed solution concentrations of thorium nitrate gave any significant increase in mean particle diameters over those obtained from nitrate solutions of lower concentrations in flame denitration. A hydraulic film resistance has been detected in the anion exchange of uranyl sulfate into Dowex 2lK, and chloride elution was found to give a higher apparent uranium diffusion coefficient than nitrate elution. The rate of dissolution of mixed thorium-uranium oxides was determined as a function of the per cent of mixed oxides dissolved. Mixing in ...
Machine condition monitoring (MCM) has the capability to predict equipment maintenance needs which can reduce forced down-time and facilitate the avoidance of catastrophic failures and the consequential secondary damage. It can be used to allow confident deferral of routine maintenance, and improve equipment performance, availability, reliability and safety. In order to capitalize on the potential benefits of MCM directed toward power transformers two types of vibration tests were conducted on transformers owned and operated by Cargill Inc. and IES Utilities at the Bridgeport corn plant in Eddyville, Iowa. These tests involved collecting vibration signals from the transformer tank walls during transformer energization at no-load and during steady state operation at various loads. These vibration signals were then used to detect deterioration of internal mechanical integrity. Both types of tests conducted on the transformers at the Eddyville ...
The Federal Aviation Administration (FAA) identified 17 accidents that may have resulted from fuel tank explosions on commercial aircraft from 1959 to 2001. Seven events involved JP 4 or JP 4/Jet A mixtures that are no longer used for commercial aircraft fuel. The remaining 10 events involved Jet A or Jet A1 fuels that are in current use by the commercial aircraft industry. Four fuel tank explosions occurred in center wing tanks (CWTs) where on-board appliances can potentially transfer heat to the tank. These tanks are designated as ''Heated Center Wing Tanks'' (HCWT). Since 1996, the FAA has significantly increased the rate at which it has mandated airworthiness directives (ADs) directed at elimination of ignition sources. This effort includes the adoption, in 2001, of Special Federal Aviation Regulation 88 of 14 CFR part 21 ...
Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.
This document provides an inventory of Tank Farm equipment stored or abandoned aboveground and potentially subject to regulation. This inventory was conducted in part to ensure that Westinghouse Hanford Company (WHC) does not violate dangerous waste laws concerning storage of potentially contaminated equipment/debris that has been in contact with dangerous waste. The report identifies areas inventoried and provides photographs of equipment.
This report is an Implementation Guide for Hanford Tanks Initiative C-106 heel retrieval contract management HNF-2511 to provide a set of uniform instructions for managing the two contractors selected. The primary objective is to produce the necessary deliverables and services for the HTI project within schedule and budget.
The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Document (S/RID) is contained in multiple volumes. This document (Volume 2) presents the standards and requirements for the following sections: Quality Assurance, Training and Qualification, Emergency Planning and Preparedness, and Construction.
A possibility of short-lived isotopes production in inter-tank section between the first and the second drift tube tanks (20.45 MeV) in INR linac is considered. At the initial stage the main efforts are concentrated on production of fluorine-18 used for positron emission tomography. The results of beam forming calculations, target heating calculations, equipment activation calculations as well as installation configuration and design are presented.
This document generates a supernatant hydroxide ion depletion model based on mechanistic principles. The carbon dioxide absorption mechanistic model is developed in this report. The report also benchmarks the model against historical tank supernatant hydroxide data and vapor space carbon dioxide data. A comparison of the newly generated mechanistic model with previously applied empirical hydroxide depletion equations is also performed.
Plans for the disposal of radioactive liquid and solid wastes presently stored in double-shell tanks at the Hanford Site call for retrieval and processing of the waste to create forms suitable for permanent disposal. Waste will be retrieved from a tank using a submerged slurry pump in conjunction with one or more rotating slurry jet mixer pumps. Pacific Northwest Laboratory (PNL) has conducted tests using simulated waste slurries to assess the effects of a impinging slurry jet on the corrosion rate of the tank wall and floor, an action that could potentially compromise the tank`s structural integrity. Corrosion processes were investigated on a laboratory scale with a simulated neutralized cladding removal waste (NCRW) slurry and in a subsequent test with simulated neutralized current acid waste (NCAW) slurry. The test slurries simulated the actual NCRW and NCAW both chemically and physically. The tests ...
SRS high-level radioactive waste tanks will not experience erosion corrosion to any significant degree during slurry pump operations. Erosion corrosion in carbon steel structures at reported pump discharge velocities is dominated by electrochemical (corrosion) processes. Interruption of those processes, as by the addition of corrosion inhibitors, sharply reduces the rate of metal loss from erosion corrosion. The well-inhibited SRS waste tanks have a near-zero general corrosion rate, and therefore will be essentially immune to erosion corrosion. The experimental data on carbon steel erosion corrosion most relevant to SRS operations was obtained at the Hanford Site on simulated Purex waste. A metal loss rate of 2.4 mils per year was measured at a temperature of 102 C and a slurry velocity comparable to calculated SRS slurry velocities on ground specimens of the same carbon steel used in SRS waste tanks. Based on these data ...
Five corrosion probes were received from West Valley Nuclear Services for evaluation in simulated tank 8D-2 3rd-stage sludge wash slurry. The same waste slurry simulated was also used in a series of ongoing corrosion studies assessing the effects of in-tank sludge washing on the integrity of tank 8D-2. Two of the corrosion probes were installed in the coupon corrosion test vessels operating at {approximately}150{degrees}F to compare performance of the probes with that observed by coupon tests conducted in the same vessels. Corrosion rate data calculated from electrical resistance measurements of the corrosion probes were evaluated for this study using two slightly different approaches. One approach uses the total length of exposure of the probe to give a ``time-averaged`` value of the corrosion rate. The other approach uses a shorter period of time (relative to the length of the test) in the calculation of corrosion rate, ...
The improvement in the functions of the viscous flow calculation method VEGA-SHIP around a ship and the expansion of application range were described as the numerical flow simulation in ship and ocean engineering and at the same time application examples to the ocean engineering by the general-purpose flow simulation code FLOW-3D handling the non-steady flow with a free surface were introduced as the numerical simulation regarding such products as a water gate and a dam. In the VEGA-SHIP, water surface was handled as a fixed wall so that wave could not be calculated. Therefore, an algorithm for calculating wave on the water surface was added to the VEGA-SHIP and a calculation method simultaneously considering the creation of wave around the ship and viscosity was developed. The FLOW-3D was used to calculate the phenomenon where inside liquid moved greatly due to the oscillation of a tank and hit against and damaged the tank ceiling in the ...
Laboratory experiments were conducted to simulate the transfer of acidic THOREX waste from Tank 8D-4 into the alkaline PUREX waste in Tank 8D-2 at West Valley. The purpose of the experiments was to explore means of minimizing the production of nitric oxide (NO) gas during mixing of the two wastes and to assess the potential for the gas to further react in the vapor space possibly leading to enhanced corrosion of the tank walls. Forty one THOREX/PUREX mixing tests were conducted to explore the effects of stirring rate, pH, THOREX addition rate, THOREX or PUREX dilution, and temperature. The two most important criteria for minimizing NO production were to maintain some degree of agitation and the keep the pH in the PUREX high, preferably >12. Steel corrosion tests were performed in the presence of low partial pressures of NO{sub 2} and liquid water or water vapor. The NO{sub 2} (from oxidation of NO in the vapor space) ...
This paper presents a method for analyzing the seismic response of a flat bottomed cylindrical liquid storage tank to vertical earthquake excitation. Here, vertical earthquake acceleration is considered to correspond to an increase in the density of a stored liquid. Taking into account the vertical and horizontal earthquake loads, hydrostatic pressure, and considering restrictive moment and shear forces at shell-bottom welded joint, the author has calculated circumferential and longitudinal stresses. These are combined to more accurately approximate the stresses at the base shell course. The calculated result closely conforms to the actual damage, termed ''elephant's foot,'' observed in the fuel storage tanks damaged in the Tangshan earthquake. This result shows that the ''elephant's foot'' phenomenon is not caused by buckling of the ...
Plans for the disposal of radioactive liquid and solid wastes presently stored in double-shell tanks at the Hanford Site call for retrieval and processing of the waste to create forms suitable for permanent disposal. Waste will be retrieved from a tank using a submerged slurry pump in conjunction with one or more rotating slurry jet mixer pumps. Pacific Northwest Laboratory (PNL) has conducted tests using simulated waste slurries to assess the effects of a impinging slurry jet on the corrosion rate of the tank wall and floor, an action that could potentially compromise the tank's structural integrity. Corrosion processes were investigated on a laboratory scale with a simulated neutralized cladding removal waste (NCRW) slurry and in a subsequent test with simulated neutralized current acid waste (NCAW) slurry. The test slurries simulated the actual NCRW and NCAW both chemically and physically. ...
An independent investigation of pipe welding leaks from the Low-Level Waste 2 (LLW2) Skid-B System for the possibilities of improper welding (IW), microbiologically influenced corrosion (MIC), sensitization, chloride pitting corrosion (CPC), and intergranular stress corrosion cracking (IGSCC) was conducted. The results show the prevailing mechanisms that caused the leaks are identified as IW, CPC, and the improper selection of weld filler material for the base metals in an environment of the North Plateau underground water. These is no evidence of MIC, sensitization, or IGSCC. The chloride pitting corrosion mechanism that took place at all the welds are also described. All the pipelines were replaced with polyvinyl chloride (PVC) for cost saving and the LLW2 Skid B System has been successfully operating since 1999. This report summarizes the findings and recommendations associated with preventive measures for future operations. The LLW2 ...
Separation of the bulk soluble chemical salts from the insoluble metal hydroxides and radionuclides is central to the strategy of disposing Hanford tank waste. Sludge washing and caustic leaching have been selected as the primary methods for processing the 230 million L (61,000,000 gal) of Hanford tank waste. These processes are very similar to those selected for processing waste at the West Valley Site in New York and the Savannah River Site in South Carolina. The purpose of sludge washing is to dissolve and remove the soluble salts in the waste. Leaching of the insoluble solids with caustic will be used to dissolve aluminum hydroxide and chromium hydroxide, and convert insoluble bismuth phosphate to soluble phosphate. The waste will be separated into a high-level solids fraction and a liquid fraction that can be disposed of as low-level waste after cesium removal. The washing and leaching operations involve batchwise mixing, settling, and ...
Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).
Possible threats against the leak tightness of the reactor containments, due to pipe whips from hypothetical pipe ruptures in the steam- and feedwater systems, have been investigated for Forsmark 3/Oskarshamn 3, Ringhals 1, Oskarshamn 1 and Barsebaeck 2/Oskarshamn 2. Based on available drawings, such as installation drawings and isometric views of pipes, the pipe systems have been put together in new drawings with their bracing supports and containment walls. This inventory shows that pipe whips can occur on a number of places on the containments walls after hypothetical pipe ruptures in the steam- and main feedwater systems. In order to find out whether these pipe whips are real threats against the leak tightness, further analysis needs to be made but are out of the scope of this investigation.
Methodology based on probabilistic fracture mechanics (PFM) is finding increasing acceptability in demonstrating safety of Nuclear Power Plant (NPP) piping. In PFM, the methods of fracture mechanics and reliability theory are combined for assessing the reliability of components, which contain cracks. In this work, reliability assessment of Tarapur Atomic Power Plant (TAPP) 3-4 Primary Heat Transport (PHT) piping is done using PFM. Monte Carlo simulation with stratified sampling is used as a variance reduction technique. PFM model assumes a pre-existing circumferential surface crack before the start of plant operation. The crack grows in size during the lifetime of the plant due to the fatigue loading. This part-through wall crack having escaped hydro-test and pre-service inspection, may result in either a through wall flaw (leak) or may lead to the rupture of the piping. R6 method is used as failure criteria. Steam generator inlet (SGI), steam generator outlet ...
Studies were conducted to examine the pressure on fluid-filled cables of electric power transmission networks in the event of an oil leak. Transition splices between paper-insulated oil-impregnated cable systems (PILC) and solid dielectric cable is difficult to perform. A proper PILC is composed of a means to contain oil within the cable structure and to keep moisture out. A failure of the cable joint could occur if an oil leak dries out the paper. Since oil pressure in most PILC cables is high, strong mechanical means must be devised to contain the oil within the cable. Resin systems, heat shrink systems and wiped lead sleeves to reseal the PILC cable over the splice, are among the methods used to stop an oil leak. A system has been designed using an EPDM tube contained under mechanical pressure; it has proven to be effective over a wide range of pressure conditions. Test results utilizing this system were presented. 1 ...
The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw size, the structural integrity of the heat exchanger is not ...
On February 1, 1984, the US Nuclear Regulatory Commission issued Generic Letter 84-04 on the subject of postulated pipe breaks in pressurized water reactor (PWR) primary coolant loops, opening the way for pipe-whip restraint exemptions. The letter substitutes the leak-before-break (LBB) criteria for the double-ended guillotine break regarding PWR primary reactor coolant system (RCS) piping and asymmetric blowdown loads. The LBB criterion refers to the fact that a piping flaw will leak before it breaks. The current requirement to provide pipe-whip restraints is applied within the plant to all high-energy piping with a potential for damaging structures, systems, and components essential to safe reactor shutdown. This includes primary RCS piping 30 in. and larger as well as smaller piping systems. A study was performed to evaluate the applicability of the LBB criteria proposed in NUREG-1061 to the latter set. The costs and benefits of this kind of ...
Significant environmental issues and regulatory proceedings in Alberta were discussed. The Mackenzie Valley Pipeline Project was reviewed in relation to the Deh Cho First Nation's advanced actions in the federal court to enjoin the review panel from proceeding with the review process. The Deh Cho First Nation is seeking a declaration that the plan violates their rights under the Canadian Charter of Rights and Freedoms and the Constitution Act. Various regulatory and government agencies have now developed a plan to coordinate their different regulatory processes and approvals in the Cooperation Plan for the Environmental Impact Assessment and Regulatory Review of the Northern Gas Pipeline project. The Deh Cho allege that they were not afforded the opportunity to participate in the development and implementation of the plan. A review panel plans to proceed once the environmental and social impacts are determined, and the consortiums plan to minimize harm has been submitted. ...
The RESF is utilized for storage of spent fuel under emergency conditions as well as for testing of FM heads. It receives cooling supply from the PHT Pressurizing pumps and after removal of decay heat from the spent fuel it goes to the D2O Storage Tank. The geometry of the RESF system is such that it can not sustain the thermosyphon loop during SBO, due to high frictional forces. To achieve the sustained thermosyphon, modifications in the design were suggested viz., removal of the steam trap and the relief valve above it and replacement by a solenoid valve (SV-16). In the event of SBO, SV-16 will open on 'RESF channel temperature high' signal and connect to FT D2O tank. The tank, being at atmospheric pressure and at lower elevation, will provide higher cooling flow rate through the RESF channel. D2O is periodically removed from the FT D2O tank by operating a Class-II pump intermittently. The analysis ...
With specific energy of more than 200 Wh/kg, the Electric Fuel zinc-air battery delivers as much as eight times the energy of lead-acid traction battery, more than twice the energy of the nearest advanced-battery competitor, and as much energy as a tank of gasoline. (author)
Sewage waste disposal facilities in the Florida Keys include septic tanks and individual package plants in place of municipal collection facilities in most locations. In Key Largo, both facilities discharge...Full Text Available
BackgroundAgricultural practices such as the use of irrigation during rice cultivation, the use of ponds for fish farming and the storage of water in tanks for livestock provide...Full Text Available
An investigation was conducted to determine the cause of coating residue found in the test gun chambers during qualification firing of 120-mm combustible cartridge case (CCC) ammunition for the MlAl/A2 main battle tank. The CCC is coated with a clear epox...
This bibliography deals with the foundation of offshore structures like drilling or working platforms (oil and gas exploitation) or offshore tanks. Different kinds of foundations, e.g. pile foundations or shallow foundations, are described. Aspects of soil-structure interaction, engineering geology and soil mechanics are also discussed. (orig.).
A corrosion-testing program has been initiated in Purex and Redox storage tnnks to obtain corrosion data on carbon steel and three associated materials in neutralized process wastes. (C.W.H.)
The Tank Waste Remediation System (TWRS) Program mission is to store, treat, and immobilize highly radioactive Hanford Site waste (current and future tank waste and the strontium/cesium capsules) in an environmentally sound, safe, and cost-effective manner. The scope of the TWRS Waste Pretreatment Program is to treat tank waste and separate that waste into HLW and LLW fractions and provide additional treatment as required to feed LLW and HLW immobilization facilities. Enhanced sludge washing was chosen as the baseline process for separating Hanford tank waste sludge. Section 1.0 briefly discusses the purpose of the evaluation plan and provides the background that led to the choice of enhanced sludge washing as the baseline process. Section 2.0 provides a brief summary of the evaluation plan details. Section 3.0 discusses, in some detail, the technical work planned to support the evaluation of enhanced ...
A schematic diagram shows the various processing steps to be performed during feed preparation in the Hanford Waste Vitrification Plant (HWVP). The pretreated NCAW is transferred to the slurry receipt adjustment tank (SRAT) in the HWVP for concentration. Water removed during boildown is collected in the slurry mix evaporator condensate tank (SMECT). After waste treatment the water is returned to the storage tanks for eventual disposal. The pretreated Neutralized Current Acid Waste (NCAW) is concentrated in the SRAT to approximately 125 g waste oxides/ liter. Formic acid is then added at a controlled rate to improve rheological properties and achieve a required reduction/oxidation state. Reflux boiling is initiated and continued for several hours. The concentrated slurry is cooled and pumped to the slurry mix evaporator (SME). In the SME, glass frit is added, and the slurry is further concentrated to achieve a nominal ...
Baldwin County is located on the Gulf of Mexico in Alabama and has a rapidly growing population. Almost 3,000 permits for septic systems are approved annually by by the Baldwin County Health Department. More than 50% of the county's residents rely on septic systems for their d...
...limited to, emission control devices, pumps, filters, muck cookers, stills, solvent tanks, solvent containers, water separators...facility that meets the conditions of § 63.320(g). Muck cooker means a device for heating perchloroethylene-laden...
Based on the High Temperature Sodium Facility (HTSF) experience and the extensive design efforts for FFTF, procedures are in place for the unloading of the tank cars and for the fill of the FFTF reactor. Special precautions have been taken to provide safe handling and to accommodate contingencies in operation. These contingencies include special protective suits allowing personnel to enter and correct conditions arising from fill operations in the course of moving 7.71 x 10/sup 5/ kg (1.7 x 10/sup 6/ lbs) of sodium from the tank cars into the reactor vessel and its loop system.
The present invention is a device for a solar heating system having a solar collector, a storage tank connected to the solar collector, a pump for circulating liquid from the tank to the solar collector, a supply of liquid at a temperature above freezing and a connection from the supply of liquid to the solar collector for replacing any liquid lost from said solar collector. The device comprises a sensor for sensing the temperature of liquid in the solar collector, and a valve for bleeding liquid from the solar collector when the sensed temperature falls below a predetermined minimum whereby cool liquid in the solar collector is automatically replaced by liquid at a temperature above freezing.
This patent describes an electrodeless lamp. It comprises: a microwave cavity; a source of microwaves in communication with the cavity; a lamp envelope containing a plasma-forming medium mounted within the microwave cavity; a gas manifold for feeding gas to at least one gas passageway for directing a stream of gas to the outer surface of the envelope; a gas leak passageway leading from the gas manifold; a conductive mesh assembly for retaining microwaves within the cavity and permitting light to be emitted from the cavity. The assembly including gas flow blocking means for preventing the flow of gas through the gas leak passageway when the screen is in place in the lamp; and means for shutting off the source of microwaves when the gas pressure in the manifold drops below a predetermined value.
Aluminum is a principal element in alkaline nuclear sludge waste stored in high level waste (HLW) tanks at the Savannah River Site. The mass of sludge in a HLW tank can be reduced through the caustic leaching of aluminum, i.e. converting aluminum oxides (gibbsite) and oxide-hydroxides (boehmite) into soluble hydroxides through reaction with a hot caustic solution. The temperature limits outlined by the chemistry control program for HLW tanks to prevent caustic stress corrosion cracking (CSCC) in concentrated hydroxide solutions will potentially be exceeded during the sludge mass reduction (SMR) campaign. Corrosion testing was performed to determine the potential for CSCC under expected conditions. The experimental test program, developed based upon previous test results and expected conditions during the current SMR campaign, consisted of electrochemical and mechanical testing to determine the susceptibility of ASTM A516 ...
Radioactive waste has been stored in large underground storage tanks at the Hanford Site since 1944. Approximately 212 million liters of waste containing approximately 240,000 metric tons of processed chemicals and 177 mega-curies of radionuclides are now stored in 177 tanks. These caustic wastes are in the form of liquids, slurries, saltcakes, and sludge. In 1991, the Tank Waste Remediation System (TWRS) Program was established to manage, retrieve, treat, immobilize, and dispose of these wastes in a safe, environmentally sound, and cost-effective manner. The Department of Energy (DOE) has believes that it is feasible to privatize portions of the TWRS Program. Under the privatization strategy embodied in the Request for Proposal (RFP), DOE will purchase services from a contractor-owned, contractor-operated facility under a fixed-price contract. Phase I of the TWRS privatization strategy is a proof-of-concept/commercial ...
This document is the third annual revision of the plans and schedules for implementing the Federal Facility Agreement (FFA) compliance program, originally submitted in 1992 as ES/ER-17&D1, Federal Facility Agreement Plans and Schedules for Liquid Low-Level Radioactive Waste Tank Systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee. This document summarizes the progress that has been made to date in implementing the plans and schedules for meeting the FFA commitments for the Liquid Low-Level Waste (LLLW) System at Oak Ridge National Laboratory (ORNL). Information presented in this document provides a comprehensive summary to facilitate understanding of the FFA compliance program for LLLW tank systems and to present plans and schedules associated with remediation, through the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) process, of LLLW tank systems that have been removed from ...
The two tank (125,000kl each) foundations under construction are as large as 85m in diameter, and the north-side tank is to be placed over a sharper slope. The tanks are greatly different in their height from the rockbed since they are to be placed at the same level. For reduction in construction cost and time, a pile foundation design is chosen as the basic concept for foundation construction. After an overall evaluation of stability upon exposure to seismic torsion and of the deformation characteristics of piles and concrete slabs, a total pile foundation design with rock debris replaced with crushed rock is determined to be the design to be adopted. Since the piles to be driven in are greatly different in length, error in the pile supporting force will be too grave under the conventional pile landing control system. Therefore, a high-accuracy pile landing control system is employed, established after a rapid load test in ...
The results of the 2006 investigation of contaminant sources at Navarre, Kansas, clearly demonstrate the following: {sm_bullet} Sources of carbon tetrachloride contamination were found on the Navarre Co-op property. These sources are the locations of the highest concentrations of carbon tetrachloride found in soil and groundwater at Navarre. The ongoing groundwater contamination at Navarre originates from these sources. {sm_bullet} The sources on the Co-op property are in locations where the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) never conducted grain storage operations. {sm_bullet} No definitive sources of carbon tetrachloride were identified on the portion of the current Co-op property formerly used by the CCC/USDA. {sm_bullet} The source areas on the Co-op property are consistent with the locations of the most intense Co-op operations, both historically and at present. The Co-op historically stored carbon tetrachloride for retail sale and used ...
When steam generator tube denting was identified, steps were taken to retard the rate of corrosion and to develop corrective measures if possible. Techniques were developed to determine the exact shapes of the tubes, and procedures were devised to analyze resulting strain and operating stresses. Tube plugging criteria were established, and in twelve years of operation, there has been only one instance of a forced outage due to a tube leak.
This paper dealt with the identification of possible damaging mechanism of the collector of the WWER 440 steam generator, cracking of primary collectors, corrosion damage of the protective coat of the primary collector circumferential weld, cracking of breathing space in the region of blinding effect by corrosion and strain, leaking of disassembling joint of the primary collector lid and with the integrity of heat exchanging tubes.
The U. S. Department of Energy (DOE) is required by Comprehensive Environmental Response, Compensation, and Liability Act of 1980 regulations to develop a conceptual understanding of potential contaminant releases from the Hanford Site based on an evaluation of existing data and known historical practices. Polychlorinated biphenyls (PCBs) are one environmental contaminant potentially released through leaks, spills, or disposal. This document presents a summary of selected relevant existing information, including environmental studies and Hanford Site analytical data.
A technique has been developed for joining a large calcium fluoride crystal to a stainless-steel flange by means of a silver transition ring. The process involves both vacuum brazing using a copper-silver alloy and air brazing using silver chloride. This paper describes the procedure used in fabricating a high-vacuum leak-tight calcium fluoride window assembly.
This paper outlines aspects of the procedures adopted within Nuclear Electric plc for the assessment of Leak before Break arguments and the consequences arising from leakage and/or pipe failure. Only new aspects are considered such as creep, leakage, temperature and over pressure assessments and pipe whip. 7 refs.
This report provides a concise summary of the information collected and analyzed regarding the leak characteristics which define them as applicable candidates for pressure activated sealant technology. This information covers Office of Pipeline Safety reported incidents from 1985 to 1997 and was collected from existing data sources as well as operator and service company input.
Leakage of CO{sub 2} and displaced brine from geologic carbon sequestration (GCS) sites into potable groundwater or to the near-surface environment is a primary concern for safety and effectiveness of GCS. The focus of this study is on the estimation of the probability of CO{sub 2} leakage along conduits such as faults and fractures. This probability is controlled by (1) the probability that the CO{sub 2} plume encounters a conductive fault that could serve as a conduit for CO{sub 2} to leak through the sealing formation, and (2) the probability that the conductive fault(s) intersected by the CO{sub 2} plume are connected to other conductive faults in such a way that a connected flow path is formed to allow CO{sub 2} to leak to environmental resources that may be impacted by leakage. This work is designed to fit into the certification framework for geological CO{sub 2} storage, which represents vulnerable resources such as potable groundwater, ...
The invention concerns a method for the graduated introduction of finely-particulate and especially pulverously-particulate solid substance, in particular coal dust, from a pressurised proportioning tank containing a supply of solid matter into an industrial furnace with several supply points, in particular a shaft furnace such as a blast furnace or a cupola furnace, the solid matter being conveyed to the individual supply points in a flow of carrier gas heavily charged with solid matter, through a separate transport line for each supply point, the carrier gas being conveyed to the lower end section of the proportioning tank in a current which causes a local loosening in the lower section of the supply of solid matter, with the transport lines opening into the loosened area, whilst the proportioning tank that contains the solid matter is weighed continuously, the actual weight of the proportioning tank ...
CNG vehicles suffer from an uncontrolled temperature rise of the gas inside the tank during the filling process and heat exchange with the environment leads to variable filling levels. A partly filled tank reduces the range of CNG vehicles and works as a impediment to the spreading of environmentaly more friendly CNG vehicles. The increase of the pressure inside the tank combined with a prolongation of the filling time beyond three minutes can reduce the deficit of the filling process. For economic reasons the time required for refuelling should be as short as possible without the need to operate the filling station with a critical pressure. To meet this target the current technique requires further improvement. (orig.) [Deutsch] Die betriebliche Praxis bei Tankvorgaengen von Erdgasfahrzeugen zeigt, dass waehrend des Tankvorganges die Temperatur des getankten Erdgases im Fahrzeugtank ansteigt. Waehrend und nach Beendigung ...
Shut Down System - 2 (SDS - 2) of TAPP-3 and 4 works on the principle of rapid injection of gadolinium nitrate poison solution into bulk moderator in calandria using high pressure helium to shut down the reactor. This is a new system, in the context of Indian PHWRs, designed, engineered, commissioned and being operated in TAPP-3 and 4. The system design incorporates passive features such as floating polyethylene ball with ball-ball seat arrangement and locked open isolation ball valves with key interlock arrangement. This arrangement eliminates active valves downstream of poison tanks during SDS - 2 actuation. A series parallel arrangement of fast acting pilot controlled air operated valves, which keep the high pressure helium isolated from poison tanks in poised state, are the only active components. During commissioning and initial period of operation of TAPP-4, problems were encountered and were resolved by suitable modifications and the ...
This report presents and discusses results from Task 5 of the study ''Fate of Mercury in Synthetic Gypsum Used for Wallboard Production,'' performed at a full-scale commercial wallboard plant. Synthetic gypsum produced by wet flue gas desulfurization (FGD) systems on coal-fired power plants is commonly used in the manufacture of wallboard. The FGD process is used to control the sulfur dioxide emissions which would result in acid rain if not controlled. This practice has long benefited the environment by recycling the FGD gypsum byproduct, which is becoming available in increasing quantities, decreasing the need to landfill this material, and increasing the sustainable design of the wallboard product. However, new concerns have arisen as recent mercury control strategies developed for power plants involve the capture of mercury in FGD systems. The objective of this study is to determine whether any mercury is released into the atmosphere when the ...
Natural convection flow is established in KMRR (Korea Multi-Purpose Research Reactor) reflector tank at the loss of reflector circulator. To simulate the reflector tank natural convection flow with high temperatures at the inner shell and bottom plate due to nuclear heating, experimental and numerical studies in an open cavity with 'L' type heated wall made by the combination of a vertical and horizontal plate were performed. It was confirmed through these studies that the heat transfer rates were highest at the lower region of the vertical plate and the inlet region of horizontal plate and comparatively high at the middle portion of both plates. The heat transfer rate distribution of this trend shows a desirable trend for the effective natural convection cooling of KMRR reflector tank. It was also confirmed that the average Nusselts numbers at the 'L' type heated wall were lower than those obtained from the existing ...
A large temperature differential (10K) thermal storage system in a small (4400 m{sup 2}) 8-storey office building is discussed and the monitoring results are analyzed in comparison with computer simulations. Requirements were a comfortable indoor environment and system cost effectiveness. Out of four potential system concepts, the Large Temperature Differential System was chosen. It comprises a flat-type thermal stratification heat storage tank in the under floor pit of the building as the heat source for a variable flow heat pump chiller. The heat sink is a set of serially connected air handling and fan coil units. The tank`s capacity is sized for one day operation and is made as large as possible to shift the electricity demand to night time. To avoid a large size and high cost, the water temperature differential was enlarged. The role of Tokyo Electric Power Company (TEPCO) was to develop the chiller and its control system. It is concluded ...
A liquid column was used for the experiments reported in Part 1. However, it only gives the observation of the effect of fast reaction because the liquid flow was controlled to uniform laminar flow and the contact is limited to short time of around 10 ms. In practical absorbing operation, turbulence is involved in liquid flow, and the residence time for contact is long. Hence, the absorption of trace iodine in the purified air has been experimented by using a constant interface area type stirred absorption tank. Prior to the experiment, the characteristics of the absorption tank was investigated by conducting pure carbon dioxide absorption test with purified water. It gave the conclusion that the tank was sufficiently usable for fundamental researches. In short contact time absorption, the iodine dissolved and absorbed in liquid phase is affected by reaction of hypoiodous acid and poly-iodide ion formation due to hydrolysis ...
Bench-scale batch equilibration tests have been conducted with supernatants from two underground tanks at the Melton Valley Storage Tank (MVST) Facility at Oak Ridge National Laboratory (ORNL) to determine the effectiveness of selected ion exchangers in removing cesium, strontium, and technetium. Seven sorbents were evaluated for cesium removal, nine for strontium removal, and four for technetium removal. The results indicate that granular potassium cobalt hexacyanoferrate was the most effective of the exchangers evaluated for removing cesium from the supernatants. The powdered forms of sodium titanate (NaTiO) and cystalline silicotitanate (CST) were superior in removing the strontium; however, for the sorbents of suitable particle size for column use, titanium monohydrogen phosphate (TiHP {phi}), sodium titanate/polyacrylonitrile (NaTiO-PAN), and titanium monohydrogen phosphate/polyacrylonitrile (TiP-PAN) gave the best results and were about ...
A pretreatment flowsheet was tested for separating key radionuclide components from the sludge stored in one of the high level waste tanks (B-110) at the Hanford Site; this sludge resulted primarily from the bismuth phosphate process, which was one of the three major plutonium separation processes used at Handford. This test involved (1) washing with water, (2) caustic leaching, (3) acid dissolution, (4) separation of transuranic elements (TRUs) by extraction with octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide(CMPO), (5) separation of Sr by extraction with di-t-butylcyclohexano-18-crown-6, (6) separation of Cs from the acid-dissolved sludge solution by treatment with ammonium molybdophosphate (AMP), and (7) separation of Cs from the sludge wash and caustic leach solutions by ion exchange using a phenol-formaldehyde resin (CS-100). The results of the radionuclide separation steps indicated that the proposed flowsheet is a viable approach to pretreating ...
Project W-320 Acceptance Test Report for tank 241-C-106, 296-C-006 Ventilation System Acceptance Test Procedure (ATP) HNF-SD-W320-012, C-106 Tank Process Ventilation Test, was an in depth test of the 296-C-006 ventilation system and ventilation support systems required to perform the sluicing of tank C-106. Systems involved included electrical, instrumentation, chiller and HVAC. Tests began at component level, moved to loop level, up to system level and finally to an integrated systems level test. One criteria was to perform the test with the least amount of risk from a radioactive contamination potential stand point. To accomplish this a temporary configuration was designed that would simulate operation of the systems, without being connected directly to the waste tank air space. This was done by blanking off ducting to the tank and connecting temporary ducting and an inlet air ...
We present a thorough analysis of single atom detection using optical cavities. The large set of parameters that influence the signal-to-noise ratio for cavity detection is considered, with an emphasis on detunings, probe power, cavity finesse and photon detection schemes. Real device operating restrictions for single photon counting modules and standard photodiodes are included in our discussion, with heterodyne detection emerging as the clearly favourable technique, particularly for detuned detection at high power.
The history of explosives vapor detection includes almost every detection strategy known to man. Initial attempts to utilize these techniques were dismal failures. However, with the development of the Electron Capture Detector (ECD), the first promising detection of explosives vapors became possible. The present commercial explosives detectors detect the higher vapor pressure materials but not the whole spectrum. This paper describes the basic properties of explosives molecules and our research to utilize these properties for increased detection sensitivity.
The MiniBooNE experiment [1] is motivated by the LSND observation, [2] which has been interpreted as {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, and by the atmospheric neutrino deficit, [3,4,5] which may be ascribed to {nu}{sub {mu}} oscillations into another type of neutrino. MiniBooNE is a single-detector experiment designed to: obtain {approx} 1000 {nu}{sub {mu}} {yields} {nu}{sub e} events if the LSND signal is due to {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, establishing the oscillation signal at the > 5{sigma} level as shown in Fig. 1.1; extend the search for {nu}{sub {mu}} {yields} {nu}{sub e} oscillations significantly beyond what has been studied previously if no signal is observed; search for {nu}{sub {mu}} disappearance to address the atmospheric neutrino deficit with a signal that is a suppression of the rate of {nu}{sub {mu}}C {yields} {mu}N events from the expected 600,000 per year; measure the oscillation parameters as shown in Fig. 1.2 if ...
This series of measurements with a mixed Pu-U nitrate solution (280 g Pu/liter, 180 g U/liter) in a 35.54-cm-diam cylindrical tank provides a wide variety of experimental data for subcritical configurations that can be used to verify calculational methods and nuclear data. The Pu contained 7.85 wt% {sup 240}Pu and the uranium was natural uranium. The measurements performed were: inverse count rate, prompt neutron decay constants, inverse kinetics, and frequency analysis by the {sup 252}Cf source driven method. These data are presented in sufficient detail that the results of the experiments can be calculated directly. For purposes of extrapolating to the delayed critical height the ratio of spectral densities was linear with height and thus provided the best estimate of critical height.
Abstract Uniformly distributing slurry solids in -tall- (-2:1 aspect ratio) process vessels is a significant challenge in the chemical industry. This work determined the performance of various multi-tier agitation systems in uniformly distributing a settling solid throughout water in a -tall- laboratory vessel. It used a 0.445-m ID Plexiglas tank, with a slurry height of 0.889-m, to determine how solids distribution changes with solids loading (wt.%), impeller speed, and impeller type. Some impeller types uniformly distributed the solids even before energy input exceeded 1.00-W/kg. Significantly higher energy improved solids distribution little because flow within the vessel eventually became choked.
The scope of this RA is limited to the evaluation of potential human health risks associated with a failure event of a tank containing Basin F liquid. Section 1.0 contains an introduction to the health risk assessment. Section 2.0 describes the site history, location, and land use. Section 3.0 provides a brief description of exposure pathways and potention receptors. Section 4.0 describes the sources of data used and identifies chemicals of concern. Section 5.0 discusses the toxicity of concern. Section 6.0 explains the methods used for calculation of carcinogenic risks and the noncarcinogenic hazard indexes. Section 7.0 describes uncertainties inherent in the current methodology used to determine potential human health risks. Section 8.0 presents a summary of results and conclusions. Section 9.0 includes the references cited.
Ground water is treated in the Czech Republic so that small water tanks are built above each water source to serve the primary ground water treatment; water so pretreated is then concentrated in large basins for subsequent treatment. Some water tanks where the first contact of the ground water with air takes place were selected as sites predisposed to radon accumulation. The examination was carried out near the town of Jihlava, where the bedrock contains slightly elevated radium concentrations. The average radon concentrations lay within the region of 2-4 kBq/m"3; the instantaneous values, however, exhibited appreciable periodical variations during the day. The relatively high radon concentrations will not pose a marked hazard for the personnel because the employees only reside at the sites in question for 10 to 15 minutes within 2 days, not for the whole working day
The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)
This engineering report compiles information on types and quantities of liquid waste discharged from B-Plant directly to cribs, ditches, reverse wells, etc., that are associated with B-Plant. Waste discharges to these cribs via overflow form 241-B, 241-BX, and 241-BY tank farms, and waste discharged to these cribs from sources other than B-Plant are discussed.Discharges from B-Plant to other cribs, unplanned releases, or waste remaining in tanks are not included in the report. Waste stream composition information is used to predict quantities of individual chemicals sent to cribs. This provides an accurate mass balance of waste streams from B-Plant to these cribs. These predictions are compared with known crib inventories as a verification of the process.
A small fleet of classic London Taxis (Black cabs) equipped with hydrogen fuel cell power systems is being prepared for demonstration during the 2012 London Olympics. This paper presents a Life Cycle Analysis for these vehicles in terms of energy consumption and CO2 emissions, focusing on the impacts of alternative vehicle technologies for the Taxi, combining the fuel life cycle (Tank-to-Wheel and Well-to-Tank) and vehicle materials Cradle-to-Grave. An internal combustion engine diesel taxi was used as the reference vehicle for the currently available technology. This is compared to battery and fuel cell vehicle configurations. Accordingly, the following energy pathways are compared: diesel, electricity and hydrogen (derived from natural gas steam reforming). Full Life Cycle Analysis, usin...
The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat exchanger to be short-circuited depending on the fuel temperature.
At the reference plant (Wolsung unit No. 1) a manual poison sampling system is provided to periodically sample gadolinium from each tank and analyze it in the laboratory to provide assurance that adequate poison concentration in each tank is maintained. The AECB required a continuous, on-line monitoring system. On Wolsung unit No. 2, process piping adapter and new instrument loops added to the Liquid Injection Shutdown System(LISS) which is part of SDS2. The new instrument loops continuously monitor SDS2 poison conductivity and initiate an alarm when the poison concentration is too low. 8 refs., 1 fig. (author).
This report describes experiments to determine whether a wiped film evaporator (WFE) might be used to concentrate low-level liquid radioactive waste (LLLW). Solutions used in these studies were surrogates that contain no radionuclides. The compositions of the surrogates were based on one of Oak Ridge National Laboratory`s (ORNL`s) Melton Valley Storage Tanks (MVSTs). It was found that a WFE could be used to concentrate LLLW to varying degrees by manipulating various parameters. The parameters studied were rotor speed, process fluid feed temperature and feed rate, and evaporator temperature. Product consistency varied from an unsaturated liquid to a dry powder. Volume reductions up to 68% were achieved. System decontamination factors were consistently in the range of 10{sup 4}.
This paper presents a novel domestic hot water heater model to be used in a multi-objective demand side management program. The model incorporates both the thermal losses and the water usage to determine the temperature of the water in the tank. Water heater loads are extracted from household load data and then used to determine the household water usage patterns. The benefits of the model are: (1) the on/off state of the water heater and temperature of the water in the tank can be accurately predicted, and (2) it enables the development of water usage profiles so that users can be classified based on usage behaviour. As a result, the amount of ancillary services and peak shaving that can be achieved are accurately predictable and can be maximized without adversely affecting users. (author)
In order to study nuclear criticality safety related to the development of fast breeder technology, /sup 252/Cf-source-driven neutron noise analysis measurements were performed with a Pu-U nitrate solution in a slab tank of various heights and thickness varying 11.43 cm to 19.05 cm. The results and conclusions of these experiments are (1) a capability to measure the subcriticality of a multiplying system of slab geometry to a k/sub eff/ as low as 0.7 was demonstrated, (2) calculated neutron multiplication factors agreed with those from the experiments within approx.0.02, and (3) the applicability of the method for plutonium solution systems was demonstrated. This paper describes measurements in which the height of the slab was varied for a fixed thickness and the thickness varied for a fixed height, which are the first applications of this measurement method to slab geometry.
The thermal dissolver, the main reactor of the SRC unit, has suffered a recurring problem. Specifically, it has been observed that whenever the reactor vessel is cooled to below 400/sup 0/F, its bottom head gasket leaks. An analysis of the thermal stress induced in the gasket, owing to transients across the bottom head flange, was sought. The analysis was facilitated by judiciously dividing a symmetric section of the reactor into 79 differential elements. Heat balances have been developed around each element. A numerical technique, the backward finite-difference approach, was employed to obtain the thermal behavior across the bottom head flange as a function of reactor heat-up time. The analysis performed affords an explanation for the failure of the gasket. Based on results of this work, recommendations have been suggested to provide the gasket and bolt stress requirements that are necessary to avoid leaks due to temperature changes.
The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) heat leaks to various components of the TPC magnet cryogenics system besides the magnets and control dewar; (3) the control dewar and ...
The Japan Atomic Energy Research Institute has conducted a piping reliability test program to demonstrate the safety and reliability of light water reactor primary piping. In this program, pipe fatigue test, leak-before-break (LBB) verification test and pipe rupture test were carried out to examine the integrity of piping, to verify the LBB and to demonstrate the effectiveness of protective measures against jet impingement and pipe whip loads under a pipe rupture event.In the pipe fatigue test, a procedure to predict the fatigue crack growth was developed, and the integrity of piping during the plant service life was evaluated. In the LBB verification test, the pipe fracture test and the leak rate test were performed to verify the LBB in the primary piping.In the pipe rupture test, the influence of jet impingement on the target disk and the deformation behavior of whipping pipe and restraint were investigated. Using the test results, the jet ...
The leakage behavior of containments beyond design conditions and knowledge of failure modes is required for evaluation of mitigation strategies for severe accidents, risk studies, emergency preparedness planning, and siting. These studies are directed towards assessing the risk and consequences of severe accidents. An accident sequence analysis conducted on a Boiling Water Reactor (BWR), Mark I (MK I), indicated very high temperatures in the dry-well region, which is the location of the majority of electrical penetration assemblies. Because of the high temperatures, it was postulated in the ORNL study that the sealants would fail and all the electrical penetration assemblies would leak before structural failure would occur. Since other containments had similar electrical penetration assemblies, it was concluded that all containments would experience the same type of failure. The results of this study, however, show that this conclusion does not hold for PWRs ...
Upon request by the Science and Technology Agency of Japanese Government, the Japan Atomic Energy Research Institute has conducted Piping Reliability Test Program to demonstrate the safety and reliability of light water reactor primary pipings. In this report, the results of the program are summarized. In the test program, pipe fatigue tests, Leak-Before-Break (LBB) verification tests and pipe rupture tests were carried out to examine the integrity of pipings, to verify the LBB concept and to demonstrate the effectiveness of the protective measures against jet impingement and pipe whip under pipe rupture event, respectively. In the pipe fatigue tests, a procedure to predict the fatigue crack growth was developed and the integrity of piping during plant service life was demonstrated. In the LBB verification tests, pipe fracture tests and leak rate tests were performed using cracked pipes. Based on the test results, LBB in the primary pipings was ...
Various pollution abatement measures available to combat oil spills were reviewed with emphasis on biodegradation. Microorganisms naturally found in soils and groundwater can efficiently degrade a variety of organic contaminants. For certain sites, local temperature allows the microorganisms to reduce the contaminant concentrations without human intervention. In April 1994, a diesel fuel leak was found at a telecommunication station located in a park. The leak had already contaminated the surrounding soil. The first step of the clean-up procedure was to excavate the contaminated soil, followed by an evaluation to determine the extent of the remaining contamination. It was concluded that by using natural attenuation the deforestation of the remaining affected area could be prevented. In this instance, the natural attenuation process is expected to take five years for completion. 4 refs., 1 tab., 1 fig.
The fourth in a series of international Leak-Before-Break (LBB) Seminars supported in part by the US Nuclear Regulatory Commission was held at the National Central Library in Taipei, Taiwan on May 11 and 12, 1989. The seminar updated the international polices and supporting research on LBB. Attendees included representatives from regulatory agencies, electric utilities, nuclear power plant fabricators, research organizations, and academic institutions. Regulatory policy was the subject of presentations by Mr. G. Arlotto (US NRC, USA) Dr. B. Jarman (AECB, Canada), Dr.P. Milella (ENEA-DISP, Italy), Dr. C. Faidy (EDF/Septen, France ), and Dr. K. Takumi (NUPEC, Japan). A paper by Mr. K. Wichman and Mr. A. Lee of the US NRC Office of Nuclear Reactor Regulation is included as background material to these proceedings; it discusses the history and status of LBB applications in US nuclear power plants. In addition, several papers on the supporting research programs ...
Scaling criteria for a natural-circulation loop are examined. The present state of knowledge of scaling to obtain similarity during single- and two-phase flow conditions in a closed loop are reviewed, and an alternative development of two-phase similarity parameters is presented. The loop scaling criteria are the results of analyses in which flow from one component to another is considered. In this work, boundary conditions for the closed loop are developed to obtain scaling criteria for leak flow, injection flow, and heat loss to ambient. The leak scaling criteria are specialized for modeling approaches using prototypic fluid at prototypic or reduced pressures. The derived scaling parameters are examined for their application to two existing scaled test facilities: the Multi-Loop Integral System Test (MIST) facility at Babcock and Wilcox, and the UMCP 2 x 4 facility at the University of Maryland College Park. The heat loss similarity analysis ...
The solar central receiver at the Barstow Pilot Plant is a once-through steam boiler consisting of vertical arrays of Alloy 800 tubes. Water/steam leaks associated with tube bends near the receiver outlet were observed after 16 service months. The leaks resulted from through-wall cracks localized in the crown of tube bends operating in the temperature range from 550 to 650/sup 0/C. Initiation occurred on the ID (steam side) of the tube and propagated transgranular through the tube wall. Cracking was axial and circumferential; in general, the circumferential cracks were more severe than the axial cracks. Thick oxide layers showed on the ID of the receiver tubes; a 25-..mu..m thick oxide layer had formed on tubing which operated at 650/sup 0/C. In addition, an enhanced oxidation layer was observed along a narrow band in the crown of the tube. This band was up to five times thicker than the oxide elsewhere in the tube. All cracking was associated ...
The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a ...
Implementation of Noble Metal Chemical Application (NMCA) in a Boiling Water Reactor (BWR) requires injection of a noble metal compound while the reactor is idle at hot shutdown conditions. In order to minimize outage time, utilities are very pro-actively finding ways to reduce the number of critical path tasks. One of these tasks is to remove some containment vessel drywell head bolts during the NMCA idle time. This, thereby, saves the utilities outage time, or they can perform other tasks as desired. Using design basis conditions and state-of-the-art analytical techniques, detailed finite element stress analyses of the closure region are performed. Two acceptance criteria are evaluated. The first is that contained within Section III of the ASME Code for allowable stresses. The second relates to leak tightness, i.e., with bolt removal the joint must still remain leak tight. This paper describes the activities performed to justify bolt removal ...
Results of an evaluation of 18 different products that can be used as waterstops in hydraulic dams to minimize or eliminate leaks at construction joints, were discussed. The materials were tested for permeability and adherence at 23, 15 and 5 degrees C. A two-component polyurethane resin product was found to be the one that best fulfilled the evaluation criteria. It was also found that the successful injection of a borehole depends not only on selecting the product with the best performance characteristics, but also on the technique used. Hence the preparation of the resin and the pressure at which it is injected are important performance criteria. 5 refs., 6 photos, 4 figs.
Cesium recovery from the polluted layers in the 1/3 scale hydrogen negative ion source for LHD-NBI system has tested. It was found, that the cesium recovery can be produced by additional discharges as from the cesium layer, aged by tungsten and residual gas, so as from the cesium layers, polluted by an occasional water leak. The highest cesium recovery to NI production was produced by a xenon arc, while glow discharge and arcing in hydrogen were less effective. The mechanism of recovery is the ejection of cesium from the underlying enriched layer by the arc and its transport to the surface. (author)
In the safety assessment of a potential repository for spent nuclear fuel, it is important to assess the consequences of a hypothetical leak of radionuclides through the seabed and into a waterborne transport phase. Radionuclides adsorbed to sediment particles may be transported great distances through the processes of sedimentation and resuspension. This study investigates the transport patterns of sediment particles of two different sizes, released in the Forsmark and Laxemar area. The results show that the closed waters around Forsmark to a higher degree makes the particles stay in the area close to the release points
The second international conference on containment design and operation included sessions on the following topics: performance and regulatory requirements; radionuclide behaviour; severe accident design and analysis; operation, maintenance, leaking and aging of containment systems; thermal hydraulic behaviour of containment systems; hydrogen mixing and mitigation; design methods and concepts; code validation; structural analysis and response tests; passive safety systems; aerosol behaviour; containment reliability, integrity, and risk assessment; hydrogen deflagration and detonation. Due prominence was given to CANDU and other PHWR reactors. The individual papers have been abstracted separately.
Radioactive "1"4C sucrose was found to be an ideal marker for microleakage because it did not penetrate tooth tissue, dental cement, or mounting resin. The main finding is that the adhesive cements--the glass-ionomer and polycarboxylate--are significantly more effective at preventing microleakage than are the traditional phosphate cements--silicate and zinc phosphate. The differences can be as high as two orders of magnitude. The adhesive cements provide almost perfect and reliable seals. By contrast, the nonadhesive cements are erratic sealants with most of the restorations leaking.
To improve operational safety of the fuel channel for Wolsung units the recommended primary heat transport system (PHTS) operating guidelines were developed, which provides a safe operation window in terms of pressure and temperature to maintain fuel channel integrity, which is similar to pressure-temperature curves used for primary pressure boundary integrity in PWRs and deterministic Leak-Before Break (LBB) analyses were conducted using recent understanding of delayed hydride cracking (DHC) mechanism. In addition, a comparative assessment of LBB analysis was made using the procedures of Fitness For Service Guidelines(FFSG) for pressure tubes rev. 0 and rev. 1.
This paper presents the results of a model for the impact of potential contamination produced by radionuclide leaking due to long-term physical, chemical and hydrogeological processes occurring in a LILW repository and in the natural environment. The analysis contains a deterministic and also a probabilistic approach for uncertainty assessment. The input function, i.e., the source term was evaluated by using AMBER code and the entire analysis was accomplished by using GOLDSIM, a powerful tool to support probabilistic simulation in management and decision-making in engineering and science. The results obtained were compared to previous simulations and uncertainty analyses (FEHM). (authors)
The ubiquitous presence of mobile communication devices and the continuous development of mo- bile data applications, which results in high level of mobile devices' activity and exchanged data, often transparent to the user, makes privacy preservation an important feature of mobile telephony systems. We present a formal analysis of the UMTS Authentication and Key Agreement protocol, using the applied pi-calculus and the ProVerif tool. We formally verify the model with respect to privacy properties. We show a linkability attack which makes it possible, for individuals with low-cost equipment, to trace UMTS subscribers. The attack exploits information leaked by poorly designed error messages.
Plans, engineering parameters, and some test results for several FFTF core and primary sodium circuit instrument systems are presented. The systems discussed include temperature, flow, pressure, leak detectors, level sensors, fuel failure monitoring, sodium impurity analysis and cover gas monitors. Since many of these instruments are similar to those used in other fast reactors around the world, only a brief description is presented for these systems. Results of recent demonstration tests of the FFTF Under-Sodium Viewing and Ranging system are also presented. (U.K.).
A fuel plate examination was conducted in the hot cell and canal to determine the possible failure modes for three plates leaking fission products. The plates were irradiated in the Extended Life Aluminide Fuel (ELAF) program in support of university research reactor goals to increase the limits presently allowed. The examination indicated pitting corrosion to be the failure mode. Other failure modes such as: (a) nonbonded swelling, (b) excessive fuel swelling, and (c) overheating of the plates were not observed.
Characterization and performance testing of a prototype DWPF Melter No.2 Dome Heater Bus Bar are described. The prototype bus bar was designed to address the design features of the existing system which may have contributed to water leaks on Melter No.1. Performance testing of the prototype revealed significant improvement over the existing design in reduction of both bus bar and heater connection maximum temperature, while characterization revealed a few minor design and manufacturing flaws in the bar. The prototype is recommended as an improvement over the existing design. Recommendations are also made in the area of quality control to ensure that critical design requirements are met.
Problem areas in BWRs, PWRs and PHWRs, from the viewpoint of chemistry, and the problem of fission product release in nuclear reactors are discussed. These problem areas are : fuel performance, off-normal water chemistry due to condenser leaks, the transport and deposition of the activated corrosion and fission products, denting in steam generators (in the case of PWRs), ingress of air in the cover gas helium and consequent radiolysis of D_2O in the moderator circuit (in the case of PHWRs). (M.G.B.).
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
Research at the Savannah River Technology Center aided development of a technical design basis for a Waste Treatment Plant (WTP) to pre-treat and vitrify Hanford tank waste as part of the River Protection Project (RPP). The research addresses safety concerns, process optimization, and waste form compliance. This program will provide technical data to ensure that the process functions as it was designed and minimizes costs.
This paper reviews the mill flowsheet applied at the SOMAIR (Societe des Mines de l'Air) uranium mill in Niger. It focuses on the yellow cake quality improvements achieved by molybdenum and zirconium elimination through double yellow cake precipitation in tanks at first stage and through size/density control in a fluidized bed precipitator at second stage. Water saving aspects in the plant are also presented. (author)
The Waste Acceptance Preliminary Specifications (WAPS) require that the DWPF estimate the inventory of long-lived radionuclides present in the waste glass, and report the values in the Waste Form Qualification Report. In this report, conservative (biased high) estimates of the radionuclide inventory of glass produced from waste currently in the Tank Farm are provided. In most cases, these calculated values compare favorably with actual data. In those cases where the agreement is not good, the values reported here are conservative.
The Sodium Storage Facility Project Quality Assurance Plan delineates the quality assurance requirements for construction of a new facility, modifications to the sodium storage tanks, and tie-ins to the FFTF Plant. This plan provides direction for the types of verifications necessary to satisfy the functional requirements within the project scope and applicable regulatory requirements determined in the Project Functional Design Criteria (FDC), WHC-SD-FF-FDC-009.
This Test Plan outlines the testing to be done on the Special Protective Coating (SPC) Polyurea which includes: Tank Waste Compatibility, Decontamination Factor Testing, and Adhesion Strength Testing after a sample has been exposed to Radiation.
This document describes the proposed strategy for disposal of spent and failed melters from the tank waste treatment plant to be built by the Office of River Protection at the Hanford site in Washington. It describes program management activities, disposal and transportation systems, leachate management, permitting, and safety authorization basis approvals needed to execute the strategy.
Vermicomposts as a biofertilizer can be a great option for pond manuring as they never cause any long term harm to the soil like chemical fertilizer. In this study vegetable and horticulture waste was used as an important media for vermiculture. Three separate cemented tanks (6 m{sup 3} each) were used in the system as control tank, vermicompost fertilized tank and inorganic fertilizer manured tank. Monoculture of fish was carried out with cat fish, Clarias batrachus. The produced earthworms were used as fish feed. Regular monitoring of water parameter was conducted in three different ponds. Specifically, the algal biomass variation was quite helpful in analysing the behavior of the ponds. NPK value of soil samples was analyzed intermittently to know the eutrophication level. Despite the hot summer temperature in northern part of India, which is not ideal for fish growth, we have recorded an encouraging ...
The Tank Waste Remediation System (TWRS) Information Systems Definition architecture evaluated information Management (IM) processes in several key organizations. The intent of the study is to identify improvements in TWRS IM processes that will enable better support to the TWRS mission, and accommodate changes in TWRS business environment. The ultimate goals of the study are to reduce IM costs, Manage the configuration of TWRS IM elements, and improve IM-related process performance.
This document, the Standards/Requirements Identification Document (S/RID) Phase 2 Assessment Report for the subject facility, represents the results of a Performance Assessment to determine whether procedures containing S/RID requirements are fully implemented by field personnel in the field. It contains a summary report and three attachments; an assessment schedule, performance objectives, and assessments for selected functional areas.
This document, the Standards/Requirements Identification Document (S/RID) Phase I Assessment Report for the subject facility, represents the results of an Administrative Assessment to determine whether S/RID requirements are fully addressed by existing policies, plans or procedures. It contains; compliance status, remedial actions, and an implementing manuals report linking S/RID elements to requirement source to implementing manual and section.
A fluidic pump comprises a two-diode pump having a first displacement vessel, a third diode connected to receive output from the two-diode pump through a delivery line and discharge to an outlet, and a second displacement vessel connected to the delivery line. There is a feed tank at a greater height than the two-diode pump, and a drive unit for alternately pressurising and venting the first and second displacement vessels. The drive pressure required to operate the pump can be of the order of half that for a single stage 2-diode pump. (author).
The objectives of this report are: to demonstrate complete CSSX process flowsheet (proof of concept)--decontamination factor {ge} 40,000, and concentration factor {approx}15; Scientific and technical issues evaluated--stage efficiency, temperature control, hydraulic performance, long time (multi-day) operation, short-term shutdown, effect of solids, and recovery from Cs moving through strip section.
The kinetic parameters, ..cap alpha.. the coupling coefficient and tau-bar the mean neutron transit time have been determined using a reactor oscillator on the coupled-core of the Queen Mary College research reactor. By using correlation techniques it has proved possible to use detectors small enough to be inserted in the fuel tanks. It is shown that the simplified Baldwin model with one-group diffusion theory is inadequate to describe the kinetic behaviour and the experimentally-determined parameters are dependent upon the positioning of the detectors.
Software quality assurance (SQA) for robotic systems used in nuclear waste applications is vital to ensure that the systems operate safely and reliably and pose a minimum risk to humans and the environment. This paper describes the SQA approach for the control and data acquisition system for a robotic system being developed for remote surveillance and inspection of underground storage tanks (UST) at the Hanford Site.
Behavioral detection of a low-frequency (40 Hz) vibratory dipole at source distances of 1.5–24 cm was measured by classically conditioned respiratory suppression in goldfish (Carassius...Full Text Available
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
Since current microbiology methods are not suitable to detect Clostridium perfringens in formalin-fixed, paraffin-embedded tissue samples, we developed a PCR assay to detect toxin-encoding...Full Text Available
Denaturing high-performance liquid chromatography (DHPLC) has been used extensively to detect genetic variation. We used this method to detect and identify Yersinia pestis KIM5 ciprofloxacin-resistant...Full Text Available
In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows characterized by natural circulation, high Rayleigh numbers and low Reynolds numbers; validity of heat transfer ...
Here we describe the fabrication, optimization, and application of a microfluidic device that integrates microdialysis (MD) sampling, microchip electrophoresis (ME), and electrochemical detection...Full Text Available
on this technology has beenproposedas a payload on SpaceStation Freedom to be launched in the near future [1]. Direct detection 4-ary pulse position modula- ...
Due to the serovar diversity in Haemophilus (H.) parasuis, it is difficult to develop a universal serological method for detection of this pathogen....Full Text Available
Microcalcifications in mammogram have been mainly targeted as a reliable earliest sign of breast cancer and their early detection is vital to improve its prognosis. Since their size is very small and may be easily overlooked by the examining radiologist, computer-based detection output can assist the radiologist to improve the diagnostic accuracy. In this paper, we have proposed an algorithm for detecting microcalcification in mammogram. The proposed microcalcification detection algorithm involves mammogram quality enhancement using multirresolution analysis based on the dyadic wavelet transform and microcalcification detection by fuzzy shell clustering. It may be possible to detect nodular components such as microcalcification accurately by introducing shape information. The effectiveness of the proposed algorithm for microcalcification ...
Palladium chloride films have been found to be useful as ... when suitably prepared palladium chlo- ride films are exposed ... Like the palladium chloride ( PdCl2) ...
BackgroundAutofluorescence bronchoscopy is more sensitive than conventional bronchoscopy for detecting early airway mucosal lesions. Decreased specificity can lead...Full Text Available
When completed, Lawrence Livermore National Laboratory's (LLNL) National Ignition Facility (NIF) will be the world's largest laser with experimental capabilities applicable to stockpile stewardship, energy research, science and astrophysics. As construction of the conventional facilities nears completion, operations supporting the installation of specialized laser equipment have come online. Playing a critical role in the precision cleaning of mechanical parts from the NIF beamline are three pieces of aqueous cleaning equipment. Housed in the Optics Assembly Building (OAB), adjacent to NIF's laser bay, are the large mechanical parts gross cleaner (LMPGC), the large mechanical parts precision cleaner (LMPPC), and the small mechanical parts gross and precision cleaner (SMPGPC). These aqueous units, designed and built by Sonic Systems, Inc., of Newtown, Pennsylvania, not only accommodate parts that vary greatly in size, weight, geometry, surface finish and ...
This book describes one approach to building and operating biogas systems. The biogas systems include raw material preparation, digesters, separate gas storage tanks, use of the gas to run engines, and the use of the sludge as fertilizer. Chapters included are: (1) "Introduction"; (2) "Biogas Systems are Small Factories"; (3) "The Raw Materials of Biogas Digestion"; (4) "The Daily Operation of a Biogas Factory"; (5) "The Once a Year Cleaning of the Digester"; (6) "Tanks and Pipes: Storing and Moving Biogas"; (7) "The Factory's Products: Biogas"; (8) "The Factory's Products: Biofertilizer"; (9) "The ABCs of Safety"; and (10) "Conclusion: Profiting from an Appropriate Technology." Many diagrams are provided throughout this handbook. New ideas, composting, bioinsecticides, ferrocement, facts and figures, sources and resources, feasibility studies, problem solving, and vocabulary are presented in the appendices. (YP)
An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 to 2.58% in the increase in the operating cost compared with the latter. A case where the operating cost of the resolving method was sometimes larger than the proposed ...
A reflux condensing start-up system includes a steam generator, a start-up vessel connected parallel to the steam generator, a main steam line connecting steam outlets of the steam generator and start-up vessel to a steam turbine, a condenser connected to an outlet of the turbine and a feedwater return line connected between the condenser and inlets of the steam generator and start-up vessel. The start-up vessel has one or more heaters at the bottom thereof for heating feedwater which is supplied over a start-up line to the start-up vessel. Steam is thus generated to pressurize the steam generator before the steam generator is supplied with a heat transfer medium, for example liquid sodium, in the case of a liquid metal fast breeder reactor. The start-up vessel includes upper and lower bulbs with a smaller diameter mid-section to act as water and steam reservoirs. The start-up vessel can thus be used not only in a start-up operation but as a mixing tank, a water ...
An 8-week feeding trial was conducted to evaluate the use of local poultry by-product meal (PBM) in replacement of imported fishmeal in the diets of cobia, Rachycentron canadum. Six isolipidic (12%) and isoproteic (45%) experimental diets were formulated using PBM to replace fishmeal at 20, 40, 60, 80 and 100% dietary protein. Eleven juvenile cobia (initial mean weight of 30.7???0.78?g) were randomly stocked in 300-L circular fibreglass tanks and hand-fed based on the total biomass of each tank, twice a day at 0900?h and 1500?h. The fish were group weighed at 2-week intervals to monitor their growth performance in order to adjust the feeding ratio. At the end of the feeding trial, weight gains (WGs) ranging from 221 to 322% were obtained. The specific growth rate (SGR), WG and protein effi...
In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion potential was estimated to be nearly 100mV vs. SCE. The following measures against pitting corrosion were considered to be effective: (1) Removal of the particles, (2) Corrosion proofing of ...
Five cycles of loading, elution, and regeneration were performed to remove technetium from a Hanford waste sample retrieved from Tank 241-AW-101 using SuperLig 639 resin. The waste sample was diluted to 4.95 M Na plus and then was processed to remove 137Cs through dual ion exchange columns each containing 15 mL of SuperLig 644. To remove 99Tc, the cesium decontaminated solution was processed downwards through two ion exchange columns, each containing 12 mL of SuperLig 639 resin. The columns, designated as lead and lag, each had an inside diameter of 1.45 cm and a height of 30 cm. The columns were loaded in series, but were eluted and then regenerated separately. The average technetium loading for the cycles was 250 BV at 10 percent breakthrough. There was no significant difference in the loading performances among the five cycles. The percent removal of 99Tc was greater than 99.94 percent and the average decontamination factor (DF) was approximately 1.7 x 103. ...
A featfinding committee of the German Federal Parliament in July 1980 recommended to perform a ''risk-oriented study'' of the SNR-300, the German 300 MW fast breeder prototype reactor being under construction in Kalkar. The main aim of this study was to allow a comparative safety evaluation between the SNR-300 and a modern PWR, thus to prepare a basis for a political decision on the SNR-300. Methods and main results of the study are presented in this paper. In the first step of the risk analysis six groups of accidents have been identified which may initiate core destruction. These groups comprise all conceivable courses, potentially leading to core destruction. By reliability analyses, expected frequency of each group has been calculated. In the accident analysis potential failure modes of the reactor tank have been investigated. Core destruction may be accompanied by the release of significant amounts of mechanical energy. The primary coolant system of SNR-300 is ...
In this report, we have examined some of the fundamental mechanisms expected to be at work during mobilization of the waste within the double-shell tanks at Hanford. The motivation stems from the idea that in order to properly apply correlations derived from scaled tests, one would have to ensure that appropriate scaling laws are utilized. Further, in the process of delineating the controlling mechanisms during mobilization, the currently used computational codes are being validated and strengthened based on these findings. Experiments were performed at 1/50-scale, different from what had been performed in the previous fiscal years (i.e., 1/12- and 1/25-scale). It was anticipated that if the current empirical correlations are to work, they should be scale invariant. The current results showed that linear scaling between the 1/25-scale and 1/50-scale correlations do not work well. Several mechanisms were examined in the scaled tests which might have contributed to ...
The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a constant voltage distribution along the ...
The design boron concentration of the Boron Injection Tank (BIT) in Daya Bay Nuclear Power Station is 21000 #mu#g/g. The BIT should operate under high temperature to avoid boron crystallization, causing higher evaporation, frequent water makeup, higher deposition and pipe blockage to decrease the operability of the safety injection system. The author proposes to decrease the boron concentration in BIT from 21000 #mu#g/g to 7000 #mu#g/g to solve the existing problem. The safety analyses (core DNBR and containment response) are conducted and other impacts are evaluated for the BIT reduction. The analysis results show that the core DNBR meets the safety criterion and the containment pressure is within the design value for the steam line rupture accident after the BIT reduction. The feasibility study report of Daya bay BIT reduction has been approved by NNSA. The site implementation of BIT reduction has been finished successfully
This project was conducted to evaluate novel approaches for removing radioactive strontium (Sr) and cesium (Cs) from the tank wastes. The bulk of the Sr removal research conducted as part of this project investigated adsorption of Sr onto a novel adsorbent known as iron-oxide-coated sand. The second major focus of the work was on the removal of cesium. Since the chemistries of strontium and cesium have little commonality, different materials (namely, cesium scavengers known as hexacyanoferrates, HCFs) were employed in these tests. This study bridged several scientific areas and yielded valuable knowledge for implementing new technological processes. The applicability of the results extends beyond the highly specialized application niches investigated experimentally to other issues of potential interest for EMSP programs (e.g., separation of chromium from a variety of wastes using IOCS, separation of Cs from neutral and acidic wastes with EC-controlled HCFs).
The Wind2H2 system is fully functional and continues to gather performance data. In this report, specifications of the Wind2H2 equipment (electrolyzers, compressor, hydrogen storage tanks, and the hydrogen fueled generator) are summarized. System operational experience and lessons learned are discussed. Valuable operational experience is shared through running, testing, daily operations, and troubleshooting the Wind2H2 system and equipment errors are being logged to help evaluate the reliability of the system.
This analysis defines and evaluates the surface water supply system from the existing J-13 well to the North Portal. This system includes the pipe running from J-13 to a proposed Booster Pump Station at the intersection of H Road and the North Portal access road. Contained herein is an analysis of the proposed Booster Pump Station with a brief description of the system that could be installed to the South Portal and the optional shaft. The tanks that supply the water to the North Portal are sized, and the supply system to the North Portal facilities and up to Topopah Spring North Ramp is defined.
Rubber lining is used as a corrosion protection material in European flue gas desulfurization plants, for scrubbers, tanks, pipe systems, etc. Although these rubber linings can last more than 15 years, relining still is necessary. The difficulty of shutting down power station units requires that the time scale of this replacement be kept to a minimum. High-pressure water systems have proven successful as an efficient method for removal of the old lining. The working steps and time scale are demonstrated for one such relining case.
This paper presents a decision approach, and associated computer software tools, for prioritizing and selecting among technology development activities. The approach elicits and then summarizes technology development preferences from stakeholders, and then integrates preferences into a set of funding recommendations. By formalizing the technology review process, the decision approach builds consensus and clarifies the basis for final budget decisions. The software development was conducted jointly by Pacific Northwest Laboratory and Decisions Science Associates, Incorporated. The Underground Storage Tank Integrated Demonstration funded the task; however, the approach should also be valuable to the US Department of Energy Office of Technology Development, the Office of Waste Management, and the Office of Environmental Restoration.
The Waste Acceptance Preliminary Specifications (WAPS) require that the DWPF estimate the inventory of long-lived radionuclides present in the waste glass, and report the values in the Waste Form Qualification Report. In this report, conservative (biased high) estimates of the radionuclide inventory of glass produced from waste currently in the Tank Farm are provided. In most cases, these calculated values compare favorably with actual data. In those cases where the agreement is not good, the values reported here are conservative.
This document outlines the significant accomplishments of fiscal year 1998 for the Tank Waste Remediation System (TWRS) Project Hanford Management Contract (PHMC) team. Opportunities for improvement to better meet some performance expectations have been identified. The PHMC has performed at an excellent level in administration of leadership, planning, and technical direction. The contractor has met and made notable improvement of attaining customer satisfaction in mission execution. This document includes the team`s recommendation that the PHMC TWRS Performance Expectation Plan evaluation rating for fiscal year 1998 be an Excellent.
Following revisions to the Tri-Party Agreement for Hanford Site cleanup, which specified vitrification for Complete melter feasibility and system operability immobilization of the low-level waste (LLW) tests, select reference melter(s), and establish reference derived from retrieval and pretreatment of the radioactive LLW glass formulation that meets complete systems defense wastes stored in 177 underground tanks, commercial requirements (June 1996). Available melter technologies were tested during 1994 to 1995 as part of a multiphase program to select reference Submit conceptual design and initiate definitive design technologies for the new LLW vitrification mission.
The accuracy of stabilized, turreted gun systems like the 120mm gun on the M1A2 Abrams tank and the 30mm gun on the Apache helicopter are limited by, among other things, structural flexure of the gun barrel and support structure. An advanced actuation system based on piezoelectric translators and an optical fiber strain sensing system are described in conjunction with a rapid prototyping workstation for the design of distributed parameter control systems to actively minimize the effects of vibrations caused by traversing rough terrain or weapon firing.
In the experimental fast Reactor JOYO, gripper of Fuel Handling Machine and Ex-Vessel Transfer Machine that the sodium adhered is being washed with alcohol. This radioactive alcohol waste that was used to the washing is stored to the tank. If it is able to separate the alcohol and sodium in the alcohol waste it becomes possible to dispose of the alcohol waste. Japan Nuclear Institute and Fuji Electric Systems CO., LTD. Developed the device that adds carbonic acid gas to the alcohol waste and cause the sodium in the alcohol waste separated as carbonate and remove this carbonate by using the thin film evaporator. (author)
Papers are presented under 38 symposia. Subjects included reinforced concrete, protective coatings and linings, cathodic/anodic protection, chemical cleaning of boilers, managing corrosion with plastics, water treatment, HRSG boiler tube failure analysis, corrosion in oil and gas production, corrosion in petroleum refining and gas, processing, pipelines and tanks, high temperature materials, chemical process industry, aerospace equipment, materials technology developments for incinerators and waste fuel-fired processors, materials and corrosion in fossil-fuels conversion and combustion, corrosion in nuclear systems, marine corrosion, building systems, corrosion mechanisms, corrosion inhibitors and corrosion monitoring and measurement.
Some recent achievements in the field of high pressure vessels and safety devices have offered a concrete chance to the application of compressed hydrogen for fleet commercial vehicles for urban use. Accordingly with this concept, ENEA has modified a Fiat Ducato van with a dual fuel engine, retaining the gasoline tank for long distance travelling and adopting the external mixture formation technique, with hydrogen injectors developed by ENEA, for non-polluting short-range duties in urban traffic. The article deals with the rationale for this choice and gives a general view of the project. (author)
Robotics technology is successfully being transitioned from space to terrestrial applications. It is being modified and enhanced to help in the US DOE's Environmental Restoration and Waste Management Program. Some examples of these applications, ranging from large multijointed manipulators to autonomously navigated remote vehicles, are outlined in this article. They include the following: underground storage tank technology demonstration; light-duty utility arm system; remotely controlled material-handling system; remotely operated excavator; self-guided transfer vehicle. 10 figs.
Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LIQ) or ambient-temperature compressed hydrogen (CH2). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.
The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fur Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The ...
Aim: To evaluate the usefulness of routine laboratory parameters in the decision to treat refractory cardiac arrest patients with extracorporeal life support (ECLS). Methods: Sixty-six adults with witnessed cardiac arrest of cardiac origin unrelated to poisoning or hypothermia undergoing cardiopulmonary resuscitation without return of spontaneous circulation (duration: 155min [120-180], median, [25-75%-percentiles]) were included in a prospective cohort-study. ECLS was implemented under cardiac massage, using a centrifugal pump connected to a hollow-fiber membrane-oxygenator, aiming to maintain ECLS flow >=2.5l/min and mean arterial pressure >=60mmHg. Results: Forty-seven of 66 patients died within 24h from multiorgan failure and massive capillary leak. Of 19/66 patients who survived >=24h...
Seventy-one patients with intestinal injury secondary to pelvic irradiation had predominantly large bowel lesions. Seventeen cases were treated conservatively and 54 came to surgery, 28 patients having more than one operation. Following this essentially salvage surgery there were more ileal than colonic anastomotic leaks. Thirty-four patients died during the follow-up period (2-12 years), 19 from recurrent malignancy, and nine as a result of continuing radiation effects. Seventy per cent of the patients who had a radiation fistula died as a result of malignancy. Of 42000 cases of pelvic malignancy treated by irradiation over the decade 1972-1982, surgical referrals for complications constituted 1.7%, with an overall radiation-related mortality of 0.2%. It is our opinion that colostomy alone has little part to play in this condition, and a policy based on excisional surgery is suggested.
We examine the short-term price behaviour of three, size-conditioned Indian stock market indices, in response to informational shocks. A standard mean-adjusted returns model as well as the GJR-GARCH specification point towards underreaction to negative events in the medium and small capitalization indices. Also, the pre-event coefficients are generally negative and statistically significant, regardless of the sign of the shock, thus ruling out information leaks. We uncover a stable abnormal volatility pattern which increases monotonically a few days before the shock before suddenly decreasing in magnitude on the event day and beyond. We suggest uncertainty avoidance as a potential explanation of these features. The results are fairly robust across alternative event selection procedures, ti...
UO/sub 2/ definitely leaked past the O-ring in three of the tests confirming the major results of the previous work. Continuous leakage at these levels may require additional precautions under present regulatory policies. The mechanism and the time and particle size dependence for the leakage are not known, but there is some indication leakage is more likely at low temperatures. It is possible leakage is due to movement of the O-ring during temperature or pressure cycling at the beginning or end of a test. The radiotracer method involves less labor and is much less susceptible to contamination than the previous method. Future work will investigate leakage past lubricated O-rings and time dependence of leakage. 1 reference, 1 table.
This paper reviews different helium-cooled first wall and blanket designs; and compares the selection of structural materials. The authors found that the solid breeder, SiC-composite material option generates the lowest amount of induced radioactivity and afterheat and has the highest temperature capability. When combined with the direct cycle gas turbine system, it has the potential to be the most economical fusion system and can compete with advanced fission reactors. When compared to martensitic steel and V-alloy, SiC-composite is the least developed of these three structural materials, a focused development effort will be needed. Fundamental research has begun in addressing the issues of optimized composite materials, irradiation effects, leak tightness and low activation braze materials. Development of helium-cooled high heat flux components and further development of the direct cycle gas turbine system will also be needed.
In many drug dispensing devices, such as syringes and inhalers, an elatomeric gasket is used to prevent the formulation from leaking from the chamber. During device actuation, the seal is subjected to friction, which in turn causes its deformation and can cause unintentional leakage, thus dose variability. Additionally, friction of seal is responsible for a host of potential problems such undue effort required for actuation and potential wear. The mechanism of friction generation in the seal conjunction is complex, arising from adhesion of rubber in contact with the moving interface, viscous action of a thin film of fluid and deformation of seal asperities. Therefore, the first step in understanding the conjunctional behaviour of rubber seals is a fundamental study of mechanisms of frictio...
Material degradation of pressure tubes, which are the most important components in CANDU fuel channel, can only be evaluated by removing and examining them(material surveillance). This study aimed at establishment of overall evaluation technology including the evaluation of the material degradation for the integrity of pressure tubes of Wolsung units. Material tests for pressure tubes were performed as follows; (1) Evaluation on life limiting factors of pressure tubes (2) Review on leak-before-break and integrity maintenance technology of pressure tubes (3) Survey on selection criteria for tubes to be inspected and on related regulations for material surveillance (4) Analysis of material surveillance test procedure (5) Basic examinations of Wolsung unit 1 pressure tube material(TEM, texture, chemical component etc) (6) Manufacture of test equipments and test (DHCV, hydriding, grip and tensile specimen etc). 23 figs, 6 tabs, 59 refs. (Author).
Integrated Leakage Rate Test (ILRT) of containment system plays a very important role in safety of a Nuclear Power Plant. Containment system constitutes the last physical barrier to release of radioactivity from the core and is called upon to mitigate the consequences of not only accidents within the design basis, but also some of the highly unlikely severe accidents. Hence, leak tightness of containment becomes uttermost priority for the safety of plant personnel and public. The containment and associated ESFs are tested before the first criticality and there after periodically during service. The pre-operational integrated leakage rate is carried out at LOCA based design pressure, at periodic test pressure and at some intermediate pressure points to assess the leakage characteristics. This paper summarizes the various requirements and activities relevant to the ILRT of the Indian Pressurized Heavy Water Reactor (PHWR) containment system. (author)
After a brief review of the degradations occurring on tubes of Inconel 600 in steam generators of PWR power stations emphasis is put on the conditioning of the secondary water and more particularly on the condensate treatment in the units of Doel which work on heavily polluted brackish water. The important role of non-destructive testing and eddy-current testing is also pointed out, method developed by Laborelec. The operational experience shows that Belgian stations are nearly not concerned by the degradations mostly found in power stations in other countries which shows the efficiency of the conditioning of the secondary water. On the other hand, other problems have occurred, resulting from: damage caused by foreign objects; fouling of tube before commissioning, cracking of bends and at the limit of the dudgeoning and leaking plugs. (AF).
The presence of an extraneous light gas must be taken into account in consideration of centrifugal separation of uranium isotopes, when there is inevitable leakage of such a gas through the gas sealant and/or leaking in from the atmosphere. Consideration is first given to the influence of the presence of the light gas on the maximum separative power. Then the basic equation for isotope separation containing a light gas is derived from Hirschfelder's diffusion equations. This equation is solved and the separative performance is expressed in terms of the shape factor and reflux parameter. The formulas for expressing the flow configurations of the gases are obtained for a simple model in which inflow and outflow prevail throughout the centrifuge. The corresponding equation for a model in which the gases flow in two concentric thin streams is also derived. It is concluded that the influence provided by the presence of a light gas is quite significant if the gas ...
The Fast Flux Test Facility (FFTF) is a 400 MW(th) sodium cooled reactor and is the largest test reactor of its type in the world. It was designed and is being operated to serve two purposes: gaining liquid metal system experience and serving as a test bed for fuels and materials. During test operations it is possible that cladding breaches and escape of fission gas to the reactor cover gas region can occur. To identify the source of such a leak all 78 fuel pin assemblies contain ''gas tag'' with a unique ''tag'' mixture in each assembly. The mass spectrometric identification of tag isotope ratios makes possible rapid location and thus faster removal (if required) of breached test pins.
The nature and relationship of methane to coal mines is discussed and sources of information are outlined. Methods of gas analysis in general and methods for the detection of methane in use in coal mines are described. Methods of remote detection of gases and those that have application for use in underground coal mining operations are discussed. The report represents recommendations on remote methane detection systems that may find application in underground coal mines. (20 refs.)
Reclaimed Energy Company, Inc., Connersville, IN, receives waste generated from a wide variety of industrial applications which include paint, printing and degreasing companies. The wastes are stored in separate tanks and then distilled in batches (pot distillation). The recovered solvents can be returned to the originator. The residue, left after the solvents are distilled, is disposed of using an environmentally safe, economical procedure. The company worked with an engineering and fabrication firm to develop a continuous processing system that employs a mechanically agitated thin-film evaporator to distill the solvents. Successful performance of the evaporator was ensured by processing samples of solvents through the evaporator manufacturer's pilot plant facilities before the full-sized system was designed. Reclaimed Energy Company, Inc., has realized a number of advantages by going from pot distillation to the agitated thin-film evaporator system to ...
The 177 underground storage tanks at the DOE's Hanford Site contain an estimated 180 million tons of high-level radioactive wastes. It is desirable to remove and concentrate the highly radioactive fraction of the tank wastes for vitrification. Resorcinol-formaldehyde (R-F) resin, an organic ion-exchange resin with high selectivity and capacity for the cesium ion, which is a candidate ion-exchange material for use in remediation of tank wastes. The report includes information on the structure/function analysis of R-F resin and the synthetic factors that affect performance of the resin. CS-100, a commercially available phenol-formaldehyde (P-F) resin, and currently the baseline ion-exchanger for removal of cesium ion at Hanford, is compared with the R-F resin. The primary structural unit of the R-F resin was determined to consist of a 1,2,3,4-tetrasubstituted resorcinol ring unit while CS-100, was composed mainly of a ...
The Army Reactor Area (ARA) II was constructed in the late 1950s as a test site for the Stationary Low Power Reactor No. 1 (SL-1). The SL-1 was a prototype power and heat source developed for use at remote military bases using a direct cycle, boiling water, natural circulation reactor designed to operate at a thermal power of 3,000 kW. The ARA II compound encompassed 3 acres and was comprised of (a) the SL-1 Reactor Building, (b) eight support facilities, (c) 50,000-gallon raw water storage tank, (d) electrical substation, (e) aboveground 1,400-gallon heating oil tank, (f) underground 1,000-gallon hazardous waste storage tank, and (g) belowground power, sewer, and water systems. The reactor building was a cylindrical, aboveground facility, 39 ft in diameter and 48 ft high. The lower portion of the building contained the reactor pressure vessel surrounded by gravel shielding. Above the pressure vessel, in the center portion ...
The Salt Decontamination Demonstration confirmed that the precipitation process could be used for large-scale decontamination of radioactive waste sale solution. Although a number of refinements are necessary to safely process the long-term requirement of 5 million gallons of waste salt solution per year, there were no observations to suggest that any fundamentals of the process require re-evaluation. Major accomplishments were: (1) 518,000 gallons of decontaminated filtrate were produced from 427,000 gallons of waste salt solution from tank 24H. The demonstration goal was to produce a minimum of 200,000 gallons of decontaminated salt solution; (2) cesium activity in the filtrate was reduced by a factor of 43,000 below the cesium activity in the tank 24 solution. This decontamination factor (DF) exceeded the demonstration goal of a DF greater than 10,000; (3) average strontium-90 activity in the filtrate was reduced by a factor of 26 to less ...
This report describes the results of a program conducted at the Pacific Northwest Laboratory (PNL) and Westinghouse Hanford Company (WHC) to identify alternative methods to measure the surface level in the waste tanks. This program examined commercially available devices for measuring the distance to a target. This is a continuation of a program started in FY93. In the first test sequence, tests were performed.on five devices to determine their applicability to measure the surface level in the waste tanks. The devices were the Enraf-Nonius{trademark} Model 872 Radar Gauge, the Enraf-Nonius{trademark} Model 854 Advanced Technology Gauge (ATG), the Stanley Tool Laser Measuring Device, the Robertshaw Inven-Tel{reg_sign} Precision Level Gauge, and the Micro Switch Model 942 Acoustic Sensor. In addition, discussions were held with several manufacturer representatives regarding other potential devices. The results of these tests were documented in a ...
The purpose of this study was to assess the energy flux and energetic balance related to the swine production and the recycling of residues generated by the system for utilization as organic fertilizers. The experiment was carried out at Vale dos Ipes Farm, located in the city of Ouro Verde do Oeste, in the Western of Parana State. One finishing phase swine unity containing 600 animals was monitored from January to June 2005. The treatment system is composed by one steel digester with capacity for 50 m{sup 3}, one sedimentation tank, one algae tank and one bio fertilizer storage tank. The swine barn cleaning is performed by dry scratching on a daily basis. The generated residues flow by gravitation through ducts towards the digester. The duration of the hydraulic retention period was 12 days. In the calculation of energetic efficiency, the energetic component ration is the greatest energetic cost in production system of ...
There is a crescent interest in the scientific community in the study of natural circulation phenomenon. New generation of compact nuclear reactors uses the natural circulation of the fluid as a system of cooling and of residual heat removal in case of accident or shutdown. The objective of this paper is to present a study through the comparison of experimental data and numerical simulation for the natural circulation phenomenon in one and two-phase flow regime. An experimental circuit built with glass tubes is used for the experiments. Thus, it allows the thermal hydraulic phenomena visualization. There is an electric heater as the heat source, a heat exchanger as the heat sink and an expansion tank to accommodate fluid density excursions. The circuit instrumentation consists of thermocouples and pressure meters to better keep track of the flow and heat transfer phenomena. Instrumentation data acquisition is performed through a computer interface developed with ...
This Closure Report (CR) documents closure activities for Corrective Action Unit (CAU) 543, Liquid Disposal Units, according to the Federal Facility Agreement and Consent Order (FFACO, 1996) and the Corrective Action Plan (CAP) for CAU 543 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2007). CAU 543 is located at the Nevada Test Site (NTS), Nevada (Figure 1), and consists of the following seven Corrective Action Sites (CASs): CAS 06-07-01, Decon Pad; CAS 15-01-03, Aboveground Storage Tank; CAS 15-04-01, Septic Tank; CAS 15-05-01, Leachfield; CAS 15-08-01, Liquid Manure Tank; CAS 15-23-01, Underground Radioactive Material Area; CAS 15-23-03, Contaminated Sump, Piping; and CAS 06-07-01 is located at the Decontamination Facility in Area 6, adjacent to Yucca Lake. The remaining CASs are located at the former U.S. Environmental Protection Agency (EPA) Farm in Area 15. The ...
Samples of fat coal-E, its roof sandstone-A and blind coal-W from two coal mines in Hebei Province of China were brought to the laboratory to study the features of infrared thermal images and radiation temperature in the course of uni-axial load and uni-axial cycle load. To check the results of infrared remote sensing detection, two other methods, acoustic emission detection and electrical resistance detection were also used. The AGA-782 thermalvision detected change of the temperature field of the samples` surfaces. The study showed that: (1) coal rocks and sandstone in the course of loading have three types of infrared thermal image features and three types of infrared radiation temperature features; (2) infrared detection is comparable with acoustic emission detection and electrical resistance detection. Generally, the infrared ...
The Institute of Energetic and Nuclear Research - IPEN is a research and development institution, located in a densely populated area, in the city of Sao Paulo. The nuclear fuel cycle was developed from the Yellow Cake to the enrichment and reconversion at IPEN. After this phase, all the technology was transferred to private enterprises and to the Brazilian Navy (CTM/SP). Some plants of the fuel cycle were at semi-industrial level, with a production over 20 kg/h. As a research institute, IPEN accomplished its function of the fuel cycle, developing and transferring technology. With the necessity of space for the implementation of new projects, the uranium hexafluoride (UF{sub 6}) production plant was chosen, since it had been idle for many years and presented potential leaking risks, which could cause environmental aggression and serious accidents. This plant decommission required accurate planning, as this work had not been carried out in Brazil before, for this ...
During the Bruce A Nuclear Generating Station (BNGS-A) Unit 1 1997 planned outage, a dew point search method identified a leak in one steam generator(SG) tube. Subsequently, the tube was inspected with all available eddy current probes and removed for examination. The initial inspection results and metallurgical examination of the removed tube confirmed that the leak was due to intergranular attack/stress corrosion cracking (IGA/SCC) emanating from the secondary side of the tube at the top of the tubesheet location. Subsequently, eddy current and ultrasonic indications were found at the top of the tubesheet of other Alloy 600 SG tubes. To investigate the source of the indications and to validate the inspection probes, sections of 40 tubes with various levels of damage were removed. The metallurgical examination of the removed sections showed that both secondary side and primary side initiated, circumferential, stress corrosion cracking and ...
With the fire accident in Browns Ferry nuclear power plant as a turning point, the regulation against fire has been strengthened more strictly as seen in the regulatory guide of the United States Nuclear Regulatory Commission. Fire of cables is caused by either the ignition of a cable itself or spread of fire to cables. The aspect of fire is divided into the local ignition and combution and the fire extension and prepagation because of the line-shaped configuration of cables. This report describes the prevention of the spread of fire. As the materials for the prevention of fire spread, fire spread-preventing paint ''Dannekka'', sealant ''Danseal P and L'', and fire prevention tape ''FD tape'' are reported, and the testing method and the results are described in detail. ''Dannekka'' is classified into the solvent dispersion type and the water dispersion type. It may be coated with brush or by spraying. Seal material is required not only to be flame preventive but also to be ...
Since the integrity of the containment penetrations was confirmed under accident management (AM) conditions in the former test, failure criteria tests and aerosol trapping tests were carried out using low-voltage modules and flange gaskets of an actual plant under severe accident (SA) conditions, without AM. The safety margin for failure temperature of the penetrations and the credit for fission product (FP) aerosol trapping effect along the leakage paths of the degraded penetrations were evaluated in the present tests. Failure temperature of the penetrations ranged from 270 to 300degC for low-voltage modules and 300 to 350degC for flange gaskets under 0.4 to 1.0 MPa conditions. Pressure dependency on failure temperature was small. This means that the safety margin of failure temperature under AM condition is more than 70degC. By introducing a equivalent leak area for the damaged test pieces, total leak area was estimated which was smaller than ...
A new surveillance system for Oil-Filled cable, which can provide continuous monitoring, using a newly developed optical gas sensor that can detect the concentration of the gas dissolved in the oil with extremely high sensitivity has been developed. It was proved that the degree of deterioration of the insulating oil can be detected by measuring C{sub 2}H{sub 2} and CH{sub 4} by investigating the relation between the degree of deterioration and amount of combustible gas generated. In order to detect extremely small amounts of gas, a new gas detecting method using absorption line of the gas using a frequency modulated technique has been developed. The gas detection ability was also confirmed by examination using a 66 kV of cable and the possibility of detection at an early stage is expected.
BackgroundEpilepsy is a common neurological disorder characterized by recurrent electrophysiological activities, known as seizures. Without the appropriate detection strategies,...Full Text Available
A commercially available synthetic nucleic acid probe (SNAP) conjugated to alkaline phosphatase was compared with standard culture techniques for detecting Campylobacter species. The SNAP was able to...Full Text Available
This paper discusses the possible detection of magnetic monopoles and monopole tachyons. Topics considered include insects, astrophysics, general relativity theory, plants, and biotechnology. The paper was presented at an international symposium on non-conventional energy technology.
To understand the function of edges in perception of moving objects, we defined four questions to answer. Is the focus point in visual motion detection of a moving object: (1) the body or the edge of...Full Text Available
Dental caries continues to be a common chronic disease among various population groups. Patient care can be improved with detection at the earliest stage. However, current techniques do not...Full Text Available
PurposeSatisfaction of search (SOS) occurs when an abnormality is missed because another abnormality has been detected. This research studied whether the severity...Full Text Available
A rapid, sensitive, and simple method was developed to detect the sapstain fungi Ophiostoma piceae and O. quercus in stained wood. By using microwave heating for DNA...Full Text Available
We have evaluated the performance of two rapid, low-cost methods for the detection of ofloxacin (OFX) resistance with 95 Mycobacterium tuberculosis isolates from countries with high...Full Text Available
Data on a technique for the detection of antigen from arthropod vectors in a dot immunobinding assay are presented. In this system, antigen present in the vector was first solubilized in sodium dodecyl...Full Text Available
Randomly amplified polymorphic DNA (RAPD) analysis and the PCR assay were used in combination with dilution plating on a semiselective medium to detect and enumerate propagules of Trichoderma...Full Text Available
... detected (and reported) as a by-product of MRM screening (MS/MS) targeted by Law or Rule ... detected (and reported) as a by-product of MRM screening (MS/MS) targeted by Law or Rule ...
A latex agglutination (LA) test was evaluated for the detection of human rotaviruses in stool specimens. Both antiserum and immunoglobulin G (IgG)-sensitized latex particles were used, with IgG-coated...Full Text Available
A real-time immunoquantitative PCR (iqPCR) method for detection of Staphylococcus aureus enterotoxin B (SEB) was developed and evaluated using both pure cultures and foods. The assay...Full Text Available
PurposeThe aim of this investigation was to exploit lens-specific glycated crystallins as an immunogen to detect human glycated crystallins and their circulating autoantibodies in...Full Text Available
SynopsisEarly detection of late onset neonatal sepsis, prior to obvious and potentially catastrophic clinical signs, is an important goal in neonatal medicine. Sepsis causes a...Full Text Available
With the advent of dense maps of human genetic variation, it is now possible to detect positive natural selection across the human genome. Here we report an analysis of over 3 million polymorphisms...Full Text Available
The genetic systems of bacteria that have the ability to use organic pollutants as carbon and energy sources can be adapted to create bacterial biosensors for the detection of industrial pollution....Full Text Available
Bobbin-coil-type eddy current probes, which are conventionally used for nondestructive inspection of steam generator tubes in pressurized-water-type nuclear power plants, have poor detectability for circumferential flaws. Hence a new type of eddy current probe was proposed to detect effectively the magnetic flux component disturbed by a flaw and thus to eliminate the flaw direction dependency on the flaw detectability. In the course of development of the proposed method, structures of the probe were investigated based on the measurement of magnetic fields induced by exciting flat coils with several shapes. The new type of probe proposed here consists of differential pick-up coils detecting magnetic flux and exciting coils having a parallelogrammic shape, and its structure was fabricated experimentally in order to detect flaws independently of their directions. Nondestructive flaw ...
OBJECTIVE: To evaluate the commercial microparticle enzyme immunoassay (MEIA), Abbott IMx Select Chlamydia, for the detection of Chlamydia trachomatis in women and to compare its performance with endocervical...Full Text Available
We compared MRSA Select to mannitol-salt agar with 8 μg/ml cefoxitin for the detection of methicillin-resistant Staphylococcus aureus (MRSA) from 6,199 clinical...Full Text Available
The aim of this study was to evaluate a nitrate reductase assay (NRA) performed on smear-positive sputa for the direct detection of rifampin resistance in Mycobacterium tuberculosis....Full Text Available
The direct detection of pyrazinamide resistance in Mycobacterium tuberculosis is sufficiently difficult that many laboratories do not attempt it. Most pyrazinamide resistance is caused...Full Text Available
Endocervical swabs from 212 women and urethral swabs from 100 men were tested by the routine methods for McCoy cell culture and simultaneously by a novel enzyme amplified immunoassay test to detect...Full Text Available
We have discovered interstellar rubidium by observing the resonance line of Rb I at 7800 A toward zeta Oph. This is the heaviest element yet detected within the interstellar medium, and our detection of this element is important for understanding the history of nucleosynthesis in the solar neighborhood.
Objectives. We investigated increases in diarrheal illness detected through syndromic surveillance after a power outage in New York City on August 14, 2003.Methods....Full Text Available
A serodiagnostic test has been developed for the detection of Plasmodium falciparum in infected blood. Using parasite antigens and infected red blood cells from in vitro...Full Text Available
A serological trapping technique for detecting rotaviruses is described which involves coating electron microscope grids with protein A and specific rotavirus antiserum. The presence of a layer of antibodies...Full Text Available
The dielectrophoretic (DEP) crossover method has been applied to the detection of cell responses to toxicants. Time and dose responses of the human cultured leukemia (HL-60) line were measured...Full Text Available
PCR was used with the primer pair VANS1-NS21 to detect the arbuscular mycorrhizal fungus Glomus intraradices (commercial inoculum source) on roots of lettuce, zinnia, leek, pepper, and endive plants....Full Text Available
A sensitive assay based on the polymerase chain reaction for the detection of Ockelbo virus RNA was developed. Two primer pairs from the gene coding for the E2 glycoprotein were chosen. By use of a...Full Text Available
Colonies of toxin-producing Pasteurella multocida were detected with peroxidase-labeled monoclonal antibodies by a membrane assay. Examination of the specificity of the assay with 29 P. multocida cultures...Full Text Available
Since bearing is in wide use as basic parts for rotary machines, detection and diagnosis of its defects are important in practical use. To discriminate defect portions by early detection of roller bearing flaking, the conventional parameter method using peakedness is poor. Thus to directly obtain difference in waveform, the new method was applied to such detection which uses KDI as the scale of a difference in waveform, and a most neighborhood classification rule based on KDI. The detection and discrimination abilities of this method was studied mainly in experiment. The experiment used a bench scale rotor and a supporting bearing, and attempted detection and discrimination of no flaking, outer ring flaking and inner ring flaking. As a result, this method could detect and discriminate fine flaking which was never detected by conventional ...
Real-time PCR has the potential to streamline detection and identification of Cryptosporidium spp. in human clinical samples. In the present...Full Text Available
A nonmammalian test system for germ-cell mutagenesis has been developed by using the Japanese medaka fish. We describe a system for detecting DNA alterations in F1 progeny descended from the gamma-irradiated...Full Text Available
Background/AimsThe findings of several recent studies suggest that antinuclear antibodies (ANAs) are frequently detected in patients with acute hepatitis A (AHA). However, the clinical...Full Text Available
In this paper the authors prove a uniqueness theorem for the electric detection of cavities in a three dimensional solid from Cauchy data measured on the surface. The cavities, finite in number, are assumed to be insulating. The surfaces of the cavities are assumed to be smooth on the complement of a set that is, in some sense, negligible. (orig.)
Discrete masses are commonly detected during mammographic screening and most such lesions are benign. For lesions without pathognomonically benign imaging features that are still regarded likely to...Full Text Available
We prepared polyclonal antibody specific to Mycoplasma pneumoniae and examined the conditions influencing the ability of an indirect immunofluorescence test to detect the specific antigen in respiratory...Full Text Available
A sensitive and specific detection method was developed for Xanthomonas hyacinthi; this method was based on amplification of a subsequence of the type IV fimbrial-subunit gene fimA...Full Text Available
There is no gold standard diagnostic test for the detection of bovine cryptosporidiosis. Infection is usually highest in 2-week-old calves, and these calves also excrete high numbers of oocysts. These...Full Text Available
BackgroundThe commonest pathogenic DMD changes are intragenic deletions/duplications which make up to 78% of all cases and point mutations (roughly 20%) detectable...Full Text Available
We proposed a faster pedigree-based generalized multifactor dimensionality reduction algorithm, called PedG-MDR II (PII), to detect gene-gene interactions underlying complex traits. Inherited...Full Text Available
A duplex TaqMan real-time RT-PCR assay was developed for the detection of California (CAL) serogroup viruses and Cache Valley virus (CVV), for use in human surveillance. The targets selected...Full Text Available
Synthetic complementary oligonucleotides are useful hybridization probes for the detection of mRNAs and genes encoding proteins for which only a partial amino acid sequence is known. Usually this involves...Full Text Available
The design and material characteristics of garter spring were summarized and Nondestructive detection techniques of garter spring were also described. In particular, Eddy current testing of loose type garter spring was used in Wolsung unit 1 and was described in detail. The inspection technique of tight type garter spring has not been established and all candidated techniques were investigated in order to choose the possible detection technique. Candidated nondestructive techniques including RFEC, PEC, Magnetic technique using GMR sensor, AE, Guided Wave technique, and high frequency ultrasonic technique, are summarized for evaluating the detectability of tight garter spring.
Sep 16, 2010 ... Taking military operations as an example, there is evidence that stress-related behavioral disorders and mental conditions such as anxiety, ...
Thermal neutron beam from the TNRF of JRR-3M was utilized for detection of mice lung cancer in vivo. Both the static and real-time neutron imaging were tried. Very strong thermal neutron beam is necessary to detect lung cancers because small changes are hidden by the very large attenuation of thermal neutron beam by the hydrogens in the tissues. The detection was successfully performed. Especially, the Super Eye of Hamamatsu Photonics contributed very effectively. Bone marrows and cartilages were also shown clearly. If an efficient and compact neutron source will become available in future, this method will grow up as a powerful tool for biomedical application. (author).
This invention relates to new phosphor materials and to combinatorial methods of synthesizing and detecting the same. In addition, methods of using phosphors to generate luminescence are also disclosed.
Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical ...
Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical ...
In this paper, we first discuss the detection of supernova neutrino on Earth. Then we propose a possible method to acquire information about $\\theta_{13}$ smaller than $1.5^\\circ$ by detecting the ratio of the event numbers of different flavor supernova neutrinos. Such an sensitivity cannot yet be achieved by the Daya Bay reactor neutrino experiment.
The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.
A method is provided for detecting pathological macromolecules in a patient. The method is comprised of the following: obtaining body fluid from the patient; pretreating the body fluid; subjecting the pretreated body fluid to size-exclusion chromatography to create an excluded fluid; and analyzing the excluded fluid to detect macromolecules having a predetermined molecular weight. The method also allows for comparing elution spectra with reference spectra of suspect pathologic proteins.
The indirect detection of particle dark matter (DM) is based on the search for anomalous components in cosmic rays (CRs) due to the annihilation of DM pairs in the galactic halo, on the top of the standard astrophysical production. These additional exotic components are potentially detectable at Earth as spectral distortions for the various cosmic radiations: $\\chi + \\chi \\to q \\bar{q}, W^+ W^-, ... \\to \\bar{p}, \\bar{D}, e^+ \\gamma and \
ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.
We sequenced 16S rRNA genes from the vaginal swab contents of a postmenopausal woman with asymptomatic bacterial vaginosis (BV). Sequences from Atopobium vaginae were the most commonly detected. In a survey of 35 other postmenopausal women, this organism was detected in 44% with BV but not in any subjects deemed healthy. PMID:15071062
Surveillance of a population, such as a weapon stockpile, is needed to discover manufacturing defects as well as deterioration as the population ages. This article considers the risks of sampling rates for surveillance from three perspectives: detection probability of defects in a proportion of a population with pass/fail data, detection of a trend in a defective proportion of the population with pass/fail data, and detection of a trend with quantitative degradation measurements. Understanding of these risks will help the decision maker choose a sampling rate to protect against such problems of a specified size at a tolerable risk.
High-flux neutron sources are continuing to be of interest both in Canada and internationally to support materials testing for advanced power reactors, new developments in extracted-neutron-beam applications, and commercial production of selected radioisotopes. The advanced MAPLE reactor concept has been developed to meet these needs. The advanced MAPLE reactor is a new tank-type D_2O reactor that uses rodded low-enrichment uranium fuel in a compact annular core to generate peak thermal-neutron fluxes of 1 x 10"1"9 n#centre dot#s"-"1 in a central irradiation rig with a thermal power output of 50 MW. Capital and incremental development costs are minimized by using MAPLE reactor technology to the greatest extent practicable.
Surveillance and maintenance (S & M) of 75 sites were conductd by the Remedial Action Section for the Environmental Restoration Program for surplus facilities and sites contaminated with radioactive materials and/or hazardous chemicals. S & M activities on these sites were conducted from the end of their operating life until final facility disposal or site stabilization. The objectives of the Waste Area Grouping S & M Program are met by maintaining a program of routine S & M as well as by implementing interim corrective maintenance when deemed necessary as a result of site surveillance. This report briefly presents this program`s activities and includes tables indicating tank levels and dry well data for FY 1991.
Surveillance and maintenance (S M) of 75 sites were conductd by the Remedial Action Section for the Environmental Restoration Program for surplus facilities and sites contaminated with radioactive materials and/or hazardous chemicals. S M activities on these sites were conducted from the end of their operating life until final facility disposal or site stabilization. The objectives of the Waste Area Grouping S M Program are met by maintaining a program of routine S M as well as by implementing interim corrective maintenance when deemed necessary as a result of site surveillance. This report briefly presents this program's activities and includes tables indicating tank levels and dry well data for FY 1991.
The surface losses in the drift-tube linac (DTL) tanks 3 and 4 of the LANSCE linear accelerator are calculated using 3-D electromagnetic modeling with the CST MicroWave Studio (MWS). The results are used to provide more realistic power estimates for the 201.25MHz RF upgrade design within the LANSCE-R project. We compared 3-D MWS results with those from traditional 2-D Superfish computations for DTL cells and their simplified models and found differences on the level of a few percent. The differences are traced to a 3-D effect consisting in a redistribution of the surface currents on the drift tubes (DT) produced by the DT stem. The dependence of MWS results on the mesh size used in computations is also discussed.
Abstract Suspension of solids in stirred reactor is widely used for catalytic reactions, dissolution, etc. Quality of solid suspension is an important parameter required for the reliable design, optimum performance, and scale up of the system. Quality of suspension depends on local characteristics of solid velocity and hold up profiles. The present work was focused on investigating quality of solid suspension using ultrasound velocity profiler (UVP) measurements and CFD simulations. The slip velocity measurements carried out with UVP were used to evaluate different drag correlations used in CFD simulations. Results discussed in this work would be useful for extending the applications of CFD models for simulating large stirred slurry reactors.
Source Philippe (on the island of La Govave, near Haiti) is described in terms of climatic, sociological, agricultural and technical background. Because of drought conditions, it became necessary to develop a solar still to provide the town with sufficient fresh water. The still, which has been in operation since 1969, is described in some detail as is the construction process. Brackish and sea water are used to produce more than 1250 liters of fresh water each day. A windmill is used to pump the brackish water from a well to an elevated storage tank; it flows by gravity to solar still basins where it is vaporized, then condensed on a sloping glass surface and collected. Benefits of the solar still to the town's economy and health are discussed. Cost of the project was $17,000. 10 references. (MJJ)
In this paper the simulation of hybrid processes containing membrane units will be discussed. For this purpose a user-defined module for simulation and design of membrane processes was implemented into the simulation program AspenPlus. The advantages can be summarized as follows: - any combination of membrane processes with all other units already implemented in AspenPlus is possible, including internal recycle streams, - utilization of the physical property models and data bases of AspenPlus is possible, - cost and sensitivity analysis can be performed. These benefits are demonstrated in detail for a membrane vapor recovery unit for the treatment of tank farm off-gas, for a two-stage reverse osmosis plant for organic/-organic separations and for a combination of distillation and pervaporation for the separation of a dimethylcarbonate/methanol mixture. (orig.)
The Mediated Electrochemical Oxidation (MEO) system is an aqueous process which treats low-level mixed wastes by oxidizing the organic components of he waste into carbon dioxide and water. As MEO system continues to run, dissolved ash and radionuclides slowly accumulate in the anolyte and must be removed to maintain process efficiency. At such time, all of the anolyte is pumped into a still feed tank, and the silver ions need to be removed before sending the solution to a thin-film evaporator for further concentration. The efficiency of removing silver ions in the solution needs to be high enough such that the residual silver sent to Final Forms would be less than 1% wt. The purpose of this work is to develop an efficient process to remove silver ions during the MEO cleanout and to demonstrate the capability of centrifugation for separating small silver chloride particles from the solution. This development work includes lab scale experiments and bench scale tests. ...
The Rotary Mode Core Sample System (RMCSS) is used to obtain stratified samples of the waste deposits in single-shell and double-shell waste tanks at the Hanford Site. The samples are used to characterize the waste in support of ongoing and future waste remediation efforts. Four sampling trucks have been developed to obtain these samples. Truck I was the first in operation and is currently being used to obtain samples where the push mode is appropriate (i.e., no rotation of drill). Truck 2 is similar to truck 1, except for added safety features, and is in operation to obtain samples using either a push mode or rotary drill mode. Trucks 3 and 4 are now being fabricated to be essentially identical to truck 2.
The Advanced MAPLE is a research reactor design under development as a high-flux neutron source. The main performance goals for the reactor are a high peak thermal neutron flux in a heavy-water reflector tank, and a high average fast neutron flux in a central irradiation facility, with a maximum linear fuel rod rating of less than 120 kW/m. This study investigated the neutronic and reactor design consequences of the use of H_2O coolant as opposed to D_2O. The neutronics results, and several other considerations, indicate that H_2O coolant has a number of advantages. It is suggested that the H_2O coolant option be considered in the design of the Advanced MAPLE reactor. (L.L.) 9 refs., 4 figs., tab.
In the spring of 1991, the Environmental Protection Agency, Region 10 (EPA), launched an investigation into tanker waste disposal practices for vessels discharging ballast water at the Alyeska Pipeline Services Company's Ballast Water Treatment (BWT) facility and marine terminal in Valdez, Alaska. It had been alleged that the Exxon Shipping Company was transferring 'toxic wastes originating in California' to Valdez. In response, EPA decided to examine all waste streams generated on board and determine what the fate of these wastes were in addition to investigating the Exxon specific charges. An extensive Information Request was generated and sent to the shipping companies that operate vessels transporting Alaska North Slope Crude. Findings included information on cargo and fuel tank washings, cleaning agents, and engine room waste.
The ORR operated at an average power level of 29.7 MW for 85.3% of the time during this period. The reactor was shut down on fifteen occasions, nine of which were unscheduled. Reactor downtime needed for refueling and checks was normal. The reactor remained available for operation 88.3% of the time. Special tests completed during the quarter included: (1) transfer of LEU fuel elements CLE-202 and NLE-201 from core positions B-9 and B-2 to core positions C-5 and C-6 for continued operation; and (2) calculation of maximum heat flux in LEU elements CLE-201 and NLE-202 in core positions A-2 and A-8. In-service inspections included inspections of ORR decay tank, primary heat exchanger No. 4, and the 24-in. strainer.
A three-dimensional, continuous-energy, coupled neutron-gamma Monte Carlo model of the advanced neutron source (ANS) final preconceptual reference core design has been developed using MCNP Version 3b. This model contains the reactor core with control rods, the heavy-water reflector tank with shutdown rods and representative beam tubes, and the outer light-water poor. Eighty homogenized fuel zones per fuel element are used to represent the radical and axial {sup 235}U fuel grading. This model is the most sophisticated, physically accurate reactor physics model of the ANS currently available. The purpose of this summary is to demonstrate the MCNP methods and applications for the ANS.
A characterization study was performed on monosodium titanate (MST) particles to determine the effect of high shear forces expected from the In-Tank Precipitation (ITP) process pumps on the particle size distribution. The particles were characterized using particle size analysis and scanning electron microscopy (SEM). No significant changes in particle size distributions were observed between as-received MST and after 2--4 hours of shearing. Both as-received and sheared MST particles contained a large percentage of porosity with pore sizes on the order of 500 to 2,000 Angstroms. Because of the large percentage of porosity, the overall surface area of the MST is dominated by the internal surfaces. The uranium and plutonium species present in the waste solution will have access to both interior and exterior surfaces. Therefore, uranium and plutonium loading should not be a strong function of MST particle size.
Abstract Four methods were used to extract length scales from mixing data: the maximum striation thickness, point-to-nearest-neighbour (PNN) distributions, the correlogram and the variogram. Four test data sets were analysed: blending in a micromixer; particle dispersion in a stirred tank; dispersion of a smoke plume and a pulse tracer test in a reactor. The maximum striation thickness captures the largest length scale. The PNN method quantifies differences between clustered, random and regular spatial distributions. The correlogram calculation cannot be consistently used for all types of mixing data and has therefore been rejected. The variogram reveals both large-scale segregation and periodicity. Sub-sampling is needed to isolate smaller structures. The variogram, PNN and transect metho...
''Hybrid'' hydrogen storage, where hydrogen is stored in both the solid material and as a high pressure gas in the void volume of the tank can improve overall system efficiency by up to 50% compared to either compressed hydrogen or solid materials alone. Thermodynamically, high equilibrium hydrogen pressures in metal-hydrogen systems correspond to low enthalpies of hydrogen absorption-desorption. This decreases the calorimetric effects of the hydride formation-decomposition processes which can assist in achieving high rates of heat exchange during hydrogen loading-removing the bottleneck in achieving low charging times and improving overall hydrogen storage efficiency of large hydrogen stores. Two systems with hydrogenation enthalpies close to -20kJ/mol H2 were studied to investigate the h...
The purpose of the Hanford Waste Management Plan (HWMP) is to provide an integrated plan for the safe storage, interim management, and disposal of existing waste sites and current and future waste streams at the Hanford Site. The emphasis of this plan is, however, on the disposal of Hanford Site waste. The plans presented in the HWMP are consistent with the preferred alternative which is based on consideration of comments received from the public and agencies on the draft Hanford Defense Waste Environmental Impact Statement (HDW-EIS). Low-level waste was not included in the draft HDW-EIS whereas it is included in this plan. The preferred alternative includes disposal of double-shell tank waste, retrievably stored and newly generated TRU waste, one pre-1970 TRU solid waste site near the Columbia River and encapsulated cesium and strontium waste.
Geologic studies in connection with Project Discus Thrower have furnished detailed stratigraphic and structural information about northwestern Yucca Flat, Nevada Test Site. The Paleozoic rocks consist of a lower carbonate sequence, argillite of the Eleana Formation, and an upper carbonate sequence. The distribution of these rocks suggests that both top and bottom of the Eleana are structural contacts, probably thrusts or reverse faults. The overlying tuff includes several units recognized in the subsurface, such as the Fraction Tuff and tuff of Redrock Valley. Other units recognized include bedded tuff associated with the Grouse Canyon Member of Belted Range Tuff, and the Rainier Mesa and Ammonia Tanks Members of the Timber Mountain Tuff. The Timber Mountain and Grouse Canyon are extensively altered to montmorillonite (a swelling clay), possibly as a result of ponding of alkaline water. The overlying alluvium locally contains at the base a clayey, tuffaceous ...
Several natural gas vehicles have been built as part of Ford's Alternative Fuel Demonstration Fleet. Two basic methods, compressed gas (CNG), and liquified gas (LNG) were used. Heat transfer danger and the expense and special training needed for LNG refueling are cited. CNG in a dual-fuel engine was demonstrated first. The overall results were unsatisfactory. A single fuel LNG vehicle was then demonstrated. Four other demonstrations, testing different tank weights and engine sizes, lead to the conclusion that single fuel vehicles optimized for CNG use provide better fuel efficiency than dual-fuel vehicles. Lack of public refueling stations confines use to fleet operations.
To evaluate safety of horizontal steam generator used in passive safety system, it is needed to make clear flooding characteristics in U bend pipe. In this study, two-phase flow experiment in a horizontal U bend pipe was carried out to make clear the influence of the length of horizontal pipe and the radius of U bend. Flooding in the U bend pipe was observed in the condition of lower gas or liquid volumetric flux than that in the horizontal pipe or the vertical pipe. Flooding and carry-up in the U bend pipe is hardly change with increasing the length between the water inlet and the U bend, but greatly related with the length from the water inlet to the lower tank and the shape of the U bend inlet. (author).
Thirteen summaries of exploratory development work carried out under a grant to the Naval Postgraduate School Research Foundation are included. This research was carried out in the areas of electrical engineering (slot lines; phase lock loops), aeronautics (aircraft survivability; composite materials for structures), material sciences (relation between high temperature compressive behavior and microstructure), mechanical engineering (fatigue life of ferrocement hull structures; flow fields), economics (hazardous employment incentives for DoD personnel), operations research (missile allocation modeling; combat dynamics; shipboard tank designs), oceanography breakwater construction effects on ecology), and physics (evaluation of an underwater acoustic parametric source).
In this study, usage of a variable speed refrigeration system in latent heat thermal energy storage (LHTES) system is investigated to increase energy storage efficiency. Four different compressor speed control cases are compared to obtain a constant heat transfer fluid (HTF) temperature at the inlet of the energy storage tank. These control cases are (i) control with evaporation temperature, (ii) control with ethylene glycol temperature at the outlet section of evaporator, (iii) control with suction pressure of the compressor and (iv) on/off control. By means of the experimental analysis the best control strategy is obtained as control with Case (ii), in terms of stability of inlet temperature of heat transfer fluid, variations of energy efficiency of LHTES and coefficient of performance (...
This report describes the physical characteristics of a ceramic-lined, joule-heated glass melter that is directly connected to the discharge of a spray calciner and is currently being used to study the vitrification of simulated nuclear-waste slurries. Melter performance characteristics and subsequent design improvements are described. The melter contains 0.24 m/sup 3/ of glass with a glass surface area of 0.76 m/sup 2/, and is heated by the flow of an alternating current (ranging from 600 to 1200 amps) between two Inconel-690 slab-type electrodes immersed in the glass at either end of the melter tank. The melter was maintained at operating temperature (900 to 1260/sup 0/C) for 15 months, and produced 62,000 kg of glass. The maximum sustained operating period was 122 h, during which glass was produced at the rate of 70 kg/h.
FELs require tight control of the amplitudes and phase of the fields in two linear accelerator tanks to obtain stable lasing. The accelerator control loops must establish constant, stable, repeatable amplitudes and phases of the rf fields and must have excellent bandwidth to control high-frequency noise components. A model of the feedback loops has been developed that agrees well with measurements and allows easy substitution of components and circuits, thus reducing breadboarding requirements. The model permits both frequency and time-domain analysis. The accelerator control scheme and model are described and the control of noise in feedback loops is discussed, showing how low-frequency-noise components (errors) can be corrected, but high-frequency-noise components (errors) are actually amplified by the feedback circuit. Measurements of noise in both open- and closed-loop modes is shown and comparison is made with results from the model calculations.
Humans are exposed to chemicals in contaminated groundwaters that are used as sources of drinking water. Chemicals contaminate groundwater resources as a result of waste disposal methods for toxic chemicals, overuse of agricultural chemicals, and leakage of chemicals into the subsurface from buried tanks used to hold fluid chemicals and fuels. In the process, both the solid portions of the subsurface and the groundwaters that flow through these porous structures have become contaminated. Restoring these aquifers and minimizing human exposure to the parent chemicals and their degradation products will require the identification of suitable biomarkers of human exposure; better understandings of how exposure can be related to disease outcome; better understandings of mechanisms of transport of pollutants in the heterogeneous structures of the subsurface; and field testing and evaluation of methods proposed to restore and cleanup contaminated aquifers. In this review, ...
Novel and unprecedented ion exchange resin cleaning system, for use in BWR plants and featuring a vibration separator and basic design factors of Radiological Solutions, Inc., had been delivered to Tokai No. 2 Power Station, Japan Atomic Power Company, in October 2005. This compactly-designed system effectively separates crud and resin fines from ion exchange resins, with no clogging of separation screens. It generates minimized waste liquid and has a specially designed over-pack cleaning tank. The system has been in operation for about 2 years and half now and favorable operational data, such as crud and sulfate concentration decrease in feed water and reactor water respectively, and evaluation results have been reported from Japan Atomic Power Company and so on. (author)
The concentration decay curves for the adsorption of phenol on organobentonite were obtained in an agitated tank batch adsorber. The experimental adsorption rate data were interpreted with diffusional models as well as first-order, second-order and Langmuir kinetic models. The surface diffusion model adjusted the data quite well, revealing that the overall rate of adsorption was controlled by surface diffusion. Furthermore, the surface diffusion coefficient increased raising the mass of phenol adsorbed at equilibrium and was independent of the particle diameter in the range 0.042-0.0126cm. It was demonstrated that the overall rate of adsorption was essentially not affected by the external mass transfer. The second-order and the Langmuir kinetic models fitted the experimental data quite well; however, the kinetic constants of both models varied without any physical meaning while increasing the particle size and the mass of phenol adsorbed at equilibrium. ...
In the present work, the process of carbon dioxide absorption is analyzed at high partial pressures, in aqueous solutions of 1-amino-2-propanol (monoisopropanolamine (MIPA)), in relation to the thermal effects involved. All experiments were made in a stirred-tank reactor with a plane unbroken gas-liquid interface. The variables considered were the MIPA concentration within the range 0.1--2.0 M and the temperature within the interval 288--308 K. From the results, the authors deduce that the absorption process takes place in the nonisothermal instantaneous regime and propose an equation which not only relates the experimental results of flow density with the initial concentration of amine but at the same time enables the evaluation of the rise in temperature in the gas-liquid interface.
A new semi-submersible floating structure is proposed on which three wind turbine towers are installed. This paper presents a basic characteristic of the wave-induced motion of this semi-submersible floating structure via. numerical computations and 1/150 scaled rigid model experiments in a wave tank. In the numerical computations, nonlinear damping effect due to drag forces modeled by the Morison's formula is considered in the equation of motion, where the linear hydrodynamic forces are obtained from the Green's function model. As a result, the response characteristics around the resonant frequency region were successfully improved. In addition to such basic examination, major results of feasibility studies, including the structural stability for severe wave conditions and the long-term fatigue limit state, are presented for a realistic situation.
Remote detection of chemicals using LIDAR (Light Detection and Ranging) utilizing DIAL (Differential Absorption LIDAR) is now a standard detection technique for both military and civilian activities. We have developed a novel nonlinear optical phase conjugation system that can reduce the effects of speckle noise and atmospheric turbulence on DIAL remote detection systems. We have shown numerically and experimentally that it is possible to increase the signal-to-noise (S/N) ratio for LIDAR systems under certain conditions using optical phase conjugation. This increase in S/N can result in more accurate detection of chemical effluents while simultaneously reducing the time necessary to acquire this information.
We investigated the presence of XMRV in a cohort of Quebec patients with chronic fatigue syndrome (CFS). DNA was purified from activated peripheral blood mononuclear cells (PBMCs) and PCR was used to detect XMRV gag and env in 72 patients. Anti-XMRV antibodies were searched in sera of 62 patients by Western blot analysis. Attempts to detect XMRV antigens was made, using immunofluorescence with Gag anti-p30 antiserum on activated PBMC from 50 patients. Plasma viremia was measured by RT-PCR on 9 subjects. Finally, detection of infectious virus in 113 CFS subjects was made by co-culture of PHA+IL-2 activated PBMC with human LNCaP carcinoma cells, and by infecting the same susceptible cells with plasma, using a reverse transcriptase (RT) assay as a readout in both experiments. No detection of ...
Speech perception integrates auditory and visual information. This is evidenced by the McGurk illusion where seeing the talking face influences the auditory phonetic percept and by the audiovisual detection advantage where seeing the talking face influences the detectability of the acoustic speech signal. Here, we show that identification of phonetic content and detection can be dissociated as speech-specific and non-specific audiovisual integration effects. To this end, we employed synthetically modified stimuli, sine wave speech (SWS), which is an impoverished speech signal that only observers informed of its speech-like nature recognize as speech. While the McGurk illusion only occurred for informed observers, the audiovisual detection advantage occurred for na?ve observers as well. Thi...
A method and device have been provided for distinguishing Africanized honeybees from European honeybees. The method is based on the discovery of a distinct difference in the acoustical signatures of these two species of honeybees in flight. The European honeybee signature has a fundamental power peak in the 210 to 240 Hz range while the Africanized honeybee signature has a fundamental power peak in the 260 to 290 Hz range. The acoustic signal produced by honeybees is analyzed by means of a detecting device to quickly determine the honeybee species through the detection of the presence of frequencies in one of these distinct ranges. The device includes a microphone for acoustical signal detection which feeds the detected signal into a frequency analyzer which is designed to detect the presence of either of the known fundamental wingbeat frequencies unique to the acoustical signatures ...
Giant magnetoresistance (GMR) has been used with Eddy current testing to detect small defects not only in thin film structures but also in multilayered metallic structures. This work detected small scratches in the thin film under the surface where these defects were unable to be inspected or monitored by regular testing. In addition, rotational GMR magnetic sensor based Eddy current probes were used for detecting buried corner cracks at the edge of holes in metallic structures. The results of this study proved that giant magnetoresistance is very powerful and effective to sense the magnetic field, which is the result from the perturbation of the Eddy currents caused by a defect. This method can be used for quality control of metallization layers on silicon wafer and to detect cracks in thick structures such as cracks in aging aircraft.
A method is described for controlling fuel injection in a diesel engine having a fuel injection nozzle, comprising the steps of: detecting an idling state of the diesel engine and pressure in a combustion chamber; obtaining a pressure increment rate from the pressure detected by the detecting step; selecting a valve opening pressure of the fuel injection nozzle at a relatively low level when the idling state is detected by the detecting step, thereby setting a two peaks characteristics of a fuel injection rate; and controlling the fuel injection nozzle in response to the pressure increment rate so that the pressure increment rate in the combustion chamber is maintained within a predetermined value by changing a fuel injection quantity of a pilot injection from the fuel injection nozzle.
Fuji Computed Radiography (FCR) was evaluated for detection of intracardiac calcification as compared with conventional radiography in 77 patients. Intracardiac calcification was found in 37 patients (left coronary artery: 31, right coronary artery: 11, valve: 9) on cine-fluorography. The sensitivity for detecting these calcified foci with FCR was higher than conventional screen-film method. Especially, sensitivity for detecting left coronary artery calcification with FCR was significantly higher than conventional method (71 %, 32 %) (p < 0.01), Fine anatomical details of calcification were well shown on FCR. Chest radiography using FCR is of great use for detection of intracardiac calcification. (author).
Since the mid-1990s, nuclear power plants in Korea have experienced wall thinning, leaks, and ruptures of secondary side piping caused by flow-accelerated corrosion (FAC). The pipe failures have increased as operating time progresses. In order to prevent the FAC-induced pipe failures and to develop an effective FAC management strategy, KEPRI and KOPEC have conducted a study for developing systematic FAC management technology for secondary side piping of all Korean nuclear power plants. As a part of the study, FAC analyses were performed using the CHECWORKS code. The analysis results were used to select components for inspection and to determine inspection intervals on each nuclear power plant. This paper describes the introduction of the FAC analysis method and the wall thinning trend analysis results by reactor type, system, and water treatment amine. This paper also represents the site application feasibility for secondary side piping management. The site ...
In General Electric's design of the Simplified Boiling Water Reactor (SBWR), The depressurization valves (DPV) are installed in the reactor pressure boundary: four are connected to the reactor vessel by means of nozzles, and two more are located on the main steam pipes (one DPV for each line), which act during particular transients and/or loss of coolant accidents (LOCA), consequently providing the reactor vessel with a safe quick depressurization system. Once the vessel is de pressurised, the passive gravity-driven cooling system (GDCS) starts to operate, permitting the injection of water required for continuous core cooling. DPVs are leak tight, with welded flaps, actuated by a [striker[hammer***] which is activated by an explosive mixture. The dynamic loads that open these valves include, in addition to those produced by steam (typical in any thermodynamic transient with open/close valves), other important loads that are characteristic of this type of explosive ...
A surplus USN 40 mm ammunition can was subjected to a variety of tests. Pressure tests were carried out with nitrogen gas, followed by the venting of actual Li/SO/sub 2/ cells and batteries inside the can. A fire test was also conducted on a can packed with 10 each 10-cell batteries surrounded by vermiculite. Test results indicate the US Navy (USN) 40-mm ammunition can is suitable as a shipping container for Li/SO/sub 2/ batteries on passenger aircraft. To provide a further measure of safety, a sulfur dioxide getter was incorporated into the can. Studies indicated a commercial material, ASC carbon, is suitable for this purpose. The granular material was packaged in porous paper desiccant bags and placed in the can with the batteries and vermiculite. The batteries were vented inside the sealed can and the internal pressure monitored. Pressure returned to normal within several minutes, indicating that this arrangement should prevent sulfur dioxide (SO/sub 2/) gas from ...
Because of the environmental hazard of organic solvents such as chlorinated or aromatic hydrocarbons, water soluble and biodegradable substitutes have come into use. It should be assessed how they affect soil and aquifer when spilled in leaks or accidents. This was simulated in a model system using methanol and percolation columns, one filled with material from the unsaturated subsurface and two with different materials from aquifers. The results reveal that a spill of the substitutes can also cause problems. In homogeneous soils and at long retention times until the substance reaches the aquifer, sorption and biological degradation are most likely to prevent contamination of the groundwater. When oxygen supply in the subsurface is insufficient, reducing conditions occur and sulphide is formed. The data show that much more methanol was eliminated than reflected by the consumption of electron acceptors. This indicates that sorption and anabolic turnover of the ...
Recently, the lithium ion-conductive solid electrolyte draws attention because there is a possibility of producing the maintenance-free battery which is characterized by having such advantages as high energy density and no possibility of electrolyte leak because of solid state structure. The invented lithium ion-conductive solid electrolyte is formed by sintering the granular electrolyte expressed in the following general formula: Li(1+(4-n)x)MxTi(2-x)(PO4)3 (M = mono- or di-valent cation, x = 0.1 - 0.5). Examples of the monovalent cation are Na[sup +], K[sup +], Rb[sup +], Cs[sup +], and Cu[sup +]. Examples of divalent cation are Mg[sup 2+], Fe[sup 2+], Be[sup 2+], Ca[sup 2+], Sr[sup 2+], Ba[sup 2+], Ra[sup 2+], Mn[sup 2+], Co[sup 2+], Cu[sup 2+], Ni[sup 2+], Zn[sup 2+], and Cd[sup 2+]. The electric conductivity of lithium ion is increased with the increase in the content of Li[sup +] in the electrolyte. 4 figs.
This paper describes the safety gas management system utilizing public telephone cables. Buyo Gas Co., Ltd. has installed about 100 governors for exclusive-use or use in the districts to control the gas supply to the consumers. A gas safety management system has been developed. This system consists of a pressure sensor, the terminals of gas leak alarms, and their masters. The features lie in that the system can utilize public cables, is operative at interruption of power service, can correspond to emergency situations, serves to save the cost, and can display the data constantly. For electric facilities in a governor room and the NTT cable service work, sufficient agreement with the possessor is required. In the case of non-utility electric facilities, some restrictions are imposed on the cable work for laying from privately-owned transformers, etc. Insurance for the facilities is necessary to prepare for lightning accidents. This system realizes the pipe pressure ...
The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to this regular inspection were accomplished within the range of the limit of radiation dose equivalent based ...
The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of enrichment from 3.15 wt.% to 3.4 wt.% for replacement fuel so as ...
The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of enrichment from 3.15 wt.% to 3.4 wt.% for replacement fuel so as ...
This report presents results of the 1st regular inspection of the No.2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular inspection. The exposure dose measurements (total dose, average dose and maximum dose) for the company members and ...
This report presents results of the 1st regular inspection of the No. 2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular inspection. The exposure dose measurements (total dose, average dose and maximum dose) for the company members and ...
The Executive Director for Operations (EDO) in establishing the Piping Review Committee concurred in its overall scope that included an evaluation of the potential for pipe breaks. The Pipe Break Task Group has responded to this directive. This report summarizes a review of regulatory documents and contains the Task Group's recommendations for application of the leak-before-break (LBB) approach to the NRC licensing process. The LBB approach means the application of fracture mechanics technology to demonstrate that high energy fluid piping is very unlikely to experience double-ended ruptures or their equivalent as longitudinal or diagonal splits. The Task Group's reommendations and discussion are founded on current and ongoing NRC staff actions as presented in Section 3.0 of this report. Additional more detailed comments and discussion are presented in Section 5.0 and in Appendices A and B. The obvious issues are the reexamination of the large pipe ...
This Progress Report describes the operation of the Los Alamos Meson Physics Facility (LAMPF) and the research programs carried out there for the years 1992 and 1993. The accelerator operated for over 100 days in 1992, providing beams of H{sup +}, H{sup {minus}}, and polarized H{sup {minus}} for a rich and varied research program in nuclear physics. The accelerator had only fair beam availability in 1992 (for example, the average H{sup +} beam availability was 72%), caused largely by problems in the 201-MHz rf system. A major effort was expended to address these problems before the 1993 run. These efforts were rewarded by good beam availability in 1993 and few problems with the 201-MHz system. LAMPF operated remarkably smoothly during 1993, in the midst of a period of great uncertainty in the future of the facility and the downsizing of MP Division, which led to the loss of a large number of key people to positions elsewhere in the Laboratory. The H{sup +} intensity had to be held to ...
Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application of the criteria for maximum permissible oil spill and the technique for deciding ...
The authors present arguments against nuclear energy and pro renewable energy sources. Thus, the water used in Uranium mining and primary ore processing becomes contaminated in long lived radioisotopes and so a threat for local ecosystems and communities. Then, during the fabrication, enrichment, and handling of nuclear fuel the workers are exposed to radiations and dangerous accidental radioactive leaks can occur. But, by far, the most menacing aspect of nuclear power exploitation remains the human errors in operating the nuclear plants which can result in major accidents like that from Chernobyl which spread radioactivity all over the Europe. The equipment used in nuclear facilities which is highly contaminated as well as the burned fuel implies transportation and long term storage which also present high risks. The major advantage of the nuclear energy consists in its very low environment impact and its null contribution to the greenhouse effect. In contrast, ...
A mathematical model was developed to predict the penetration of a transient fuel spray, the temporal and spatial distribution of air-fuel mixture before the end of ignition delay and the subsequent pressure rise during combustion in a Direct-Injection Diesel Engine with and without swirl. The model accounts for the non-isothermal and non-isobaric character of processes during fuel injection resulting from continuous motion of the piston. The effects of various engine operating variables on spray were studied and graphically presented. The calculated spray penetration with and without crossflow of air is compared with the available experimental data of other researchers with good agreement. The model can predict the rate of combustible-mixture formation, the rate of heat release and cylinder pressure as a function of time in direct injection (DI) diesel engine. A single-cylinder D.I. research diesel engine was operated with N-hexadecane as the engine fuel to validate the mathematical ...
Past elastic-plastic fracture studies for leak-before-break (LBB) assessment of low alloy steel pipings have been focused mostly on the behavior of base metals and their weld metals. In contrast, the heat-affected zone (HAZ) of a welded pipe has not been studied in detail primarily because the size of the HAZ is too small to make specimens for mechanical properties measurements. In this study, microstructural analyses, microhardness tests, tensile tests and J-R tests have been conducted as a function of distance from a fusion line and temperature for HAZ materials of SA106Gr.C low alloy piping steels. For the ferrite-pearlite steels such as SA106Gr.C, the HAZ specimens showed a higher yield strength and fracture toughness compared with those of its base metal. These characteristics, despite of grain coarsening, can be explained by cleaner microstructures of HAZ materials with a finer morphology of carbides compared with pearlitic-ferritic base metals. However, the ...
Sandia was presented with an opportunity in 1993 to design containers for the long term storage and transport of fissile material. This program was undertaken at the direction of the US Department of Energy and in cooperation with Lawrence Livermore National Laboratory and Los Alamos National Laboratory which were tasked with developing the internal fixturing for the contents. The hardware is being supplied by Allied Signal Federal Manufacturing and Technologies, and the packaging will occur at Mason and Hangar Corporation`s Pantex Plant. The unique challenge was to design a container that could be sealed with the fissile material contents; and, anytime during the next 50 years, the container could be transported with only the need for the pre-shipment leak test. This required not only a rigorous design capable of meeting the long term storage and transportation requirements, but also resulted in development of a surveillance program to ensure that the container ...
This article describes the nature of the electromagnetic waves, what they are and how do they affect us. Current concern is focused on exposure to low level power-frequency magnetic fields like microwave radiation from mobile phones and leaking microwave ovens; high power radiation from defence and airport radars; fields close to high voltage transmission lines; radio frequency fields from industrial welders and heaters and DC magnetic fields in aluminium smelters. These fields with frequency less than 300 GHz do not carry sufficient energy to break chemical bonds and it is assumed that they cannot damage cell DNA. The amount of radiation absorbed by a human exposed to far field electromagnetic radiation (EMR) depends on the orientation and size of the person. In the 30-300 MHz range it is possible to excite resonance in the whole or partial body such as the head. It is emphasised that since there are some evidence that electromagnetic fields do harm, a policy of ...
Radio interference and TV interference are being a problem in urban and rural areas. This interference is generated by high voltage transmission lines as well as distribution lines. The radio noise can be produced by polluted or damaged insulators, and by metal parts of the distribution lines. The corona effect on the surface of the dielectric material produces high frequency electromagnetic fields during the ionization and during the recombination period. Fields of different intensity are produced by positive voltage and negative voltage. The insulator flashover (leaking current) also produces electromagnetic fields. A new technique to measure these fields was developed. This technique measures the radiated fields on time domain and on frequency domain. This permits us to characterize the radiated field and thus identify the type of the source. Several measurements were done varying the type of the RF generator, i.e., new insulator and broken insulator. A ...
The MACSTOR/KN-400 of Wolsung power plant in Korea is a dry interim storage facilities. There are 400 long slender cylinders in MACSTOR/KN-400. In one cylinder, ten baskets where Candu spent fuels are loaded are stacked and stored. For this MACSTOR/KN-400 facilities, analyses and tests for the hypothetical accident conditions that might happen during moving and storing baskets into a cylinder were performed. The hypothetical accident conditions to be considered are two cases. One is the case of basket dropping onto the bottom plate of a cylinder. The other is the case of basket dropping onto the other basket top plate stored in the cylinder. For the drop analyses, the case of hanging cylinder and the case of cylinder on the unyielding target surface were considered. Based on the dropping analysis, testing condition was determined as the latter case that is for the cylinder on the target surface. In a basket, 60 dummy fuel bundles are loaded which have the same weight of real spent fuel ...
This study investigated the effectiveness of dealing with biological waste by composting. In particular, it examined the feasibility of recovering excess thermal energy produced in the process of composting biological waste in terms of mass and energy transport parameters required in the aerated compost bed. An experiment was performed in which a 100 dm{sup 3} adiabatic, leak-tight reactor equipped with a controlled aeration system was constructed to study the temperature and pressure distribution in the bed. Sensors were used to determine the amount and humidity of emitted gases under variable external physical conditions. The perforated bottom of the reactor allowed for bed aeration. As such, the humidity and heat were transported upwards, forced by the air pumped in and by natural convection. In terms of pressure distribution inside the composted and aerated bed, the study results showed that there were considerable differences in pressure for the selected ...
Since 1992, the fruitful collaboration of the Russian and Western-European technical support organizations (TSOs) is being continued due to the support of the European Commission. There are two main areas of activities. The first one is more of methodological assistance and enhancing RF TSOs capabilities to support Rostekhnadzor decision making process. Experience and knowledge acquired in this area projects increase RF TSOs capabilities regarding a wide spectrum of safety related issues assessment, in particular safety analyses, reactor vessel embrittlement, application of 'leak before break' concept, severe accident and accident management, fire risk evaluation, etc. The second area is focused on licensing related assessments of EC financed on site assistance projects (modernisations). This area projects promote implementation in Russia a licensing process based on a technical dialogue between operator and regulator as well contributes to transfer of Western ...
BACKGROUND AND PURPOSE Human K2P3.1 (TASK1) channels represent potential targets for pharmacological management of atrial fibrillation. K2P channels control excitability by stabilizing membrane potential and by expediting repolarization. In the heart, inhibition of K2P currents by class III antiarrhythmic drugs results in action potential prolongation and suppression of electrical automaticity. Carvedilol exerts antiarrhythmic activity and suppresses atrial fibrillation following cardiac surgery or cardioversion. The objective of this study was to investigate acute effects of carvedilol on human K2P3.1 (hK2P3.1) channels. EXPERIMENTAL APPROACH Two-electrode voltage clamp and whole-cell patch clamp electrophysiology was used to record hK2P3.1 currents from Xenopus oocytes, Chinese hamster o...
One wonders how a facility will cope with the new Clean Air Act Amendments (CAAA). Environmental engineers working in large companies' facilities and in corporate engineering groups already have an idea of how to comply with the regulations for chemical plant equipment leaks. (In fact, the rules will also affect process bins, wastewater, transfer and storage.) But those who work for smaller companies or who have assignments not directly tied to environmental affairs may not have access to the latest thinking on compliance. One of the first challenges in becoming aware of the CAAA regulations is learning the new language, which consists of acronyms, some containing other acronyms. NESHAP, for example, stands for national emissions standards for hazardous air pollutants. Prior to the CAAA, NESHAPs applied to a few specific chemicals, such as benzene. Now the proposed rules establish a HON, a hazardous organic NESHAP. According to David Gustafson, environmental air ...
Transmission terminations available today are very reliable, but they need to be. In the field, they are continually exposed to pollution and extremes of ambient temperature. In many cases, they are in the rifle sights of vandals. In contrast, cable joints - often cited as the weakest links from an electrical viewpoint - are generally protected from physical damage underground and many of the short cable systems being installed in the US today can be built without joints. All cable systems need terminations - mostly to air-insulated equipment. At 69 through 138 kV, there is intense competition among manufacturers to supply terminations for solid-dielectric cable that are low in cost, reliable, and require a minimum of skill to install. Some utilities are looking also for terminations that fit a range of cable sizes; terminations that do not contain liquid that can leak out; and terminations that are shatter-proof. All of these improvements are available in the US ...
RELAP5 (Reactor Excursion and Leak Analysis Program) is a system code developed at the Idaho National Environmental and Engineering Laboratory for thermal hydraulic analysis of nuclear reactors. The code RELAP5 is widely used for safety analysis studies of commercial nuclear power plants. However, recent released version of RELAP5/3.2 and over present significant capabilities for analysis of nuclear reactor research systems. As a contribution to the assessment of RELAP5/3.3 for research reactor safety analysis, experimental data from the University of Massachusetts Lowell Research Reactor UMLRR are used. The UMLRR is a 1 MW, light water moderated and cooled, graphite-reflected, open-pool type research reactor. This paper presents the development and the validation of a UMLRR-RELAP model using experimental data. For this purpose, a series of experiments were performed for benchmarking RELAP5 calculations for research reactor systems. As a result of this study, the ...
A unified model is presented for a class of combined energy systems, in which the systems mainly consist of a heat engine, a combustor and a counter-flow heat exchanger and the heat engine in the systems may have different thermodynamic cycle modes such as the Brayton cycle, Carnot cycle, Stirling cycle, Ericsson cycle, and so on. Not only the irreversibilities of the heat leak and finite-rate heat transfer but also the different cycle modes of the heat engine are considered in the model. On the basis of Newton's law, expressions for the overall efficiency and power output of the combined energy system with an irreversible Brayton cycle are derived. The maximum overall efficiency and power output and other relevant parameters are calculated. The general characteristic curves of the system are presented for some given parameters. Several interesting cases are discussed in detail. The results obtained here are very general and significant and can be used to ...
The Control Rod Drive(CRD) nozzles for PWR nuclear power plants(NPP) house the control rod drives. The number of nozzle penetrations range from the mid-30's to over 100 in each reactor head. The integrity of CRD nozzles is very important, because the primary pressure boundary is established with the J-groove weld joining the nozzle to the head clad surface. The Alloy 600 PWSC CRD nozzle leaks discovered in the fall of 2000 and spring of 2001 in several US plants. Therefore the NRC has recommended a more proactive effort by US utilities to inspect similarly susceptible nozzles in all US plants. The primary safety concern is circumferential cracks that can permit the nozzles to separate from the head at high velocity and produce a large-break leak in the reactor vessel. A secondary concern is head leakage from any through-wall cracks in the nozzle or J-groove weld area. Numerous inspection and repair tools have been developed to address ...
The fault detection and diagnosis system for gas engines was developed to improve the reliability of cogeneration systems (CGS). Most of existing fault detection systems monitor the trend of each part condition of engines and diagnose faults based on trend change, resulting in slow detection. Although early detection systems are available, those are complex, expensive and poor in flexibility and applicability. Since CGSs combined with gas engines increased to 1/3 of the whole CGS, engine troubles cause possible serious faults. The fault diagnosis system was thus developed to prevent serious faults which can early detect, in particular, abnormal conditions of parts around a combustion chamber such as ignition plug, intake valve and exhaust valve by monitoring exhaust pressure waveforms in an exhaust collector. Since this system can detect progressive occurrence ...
Embedded systems have become integral parts of a diverse range of systems from automobiles to critical infrastructure applications such as gas and electric power distribution. Unfortunately, research on computer security in general and intrusion detection in particular, has not kept pace. Furthermore, embedded systems, by their very nature, are application specific and therefore frameworks for developing application-specific intrusion detection systems for distributed embedded systems must be researched, designed, and implemented. In this paper, we present a configurable middleware-based intrusion detection framework. In particular, this paper presents a system model and a concrete implementation of a highly configurable intrusion detection framework that is integrated into MicroQoSCORBA, a highly configurable middleware framework developed for embedded systems. By exploiting the application-specific ...
The subcriticality of two interacting solution tanks was determined using /sup 252/Cf-source-driven neutron noise analysis methods. These experiments were the first test of this method for an interacting system with materials (in this case, uranyl nitrate) typical of nuclear materials in processing plants. The experiments were performed to test the conclusions from previous interaction experiments with uranium metal discs for a fissile system with moderation, and to provide data to test theoretical models for coupled systems. The uranium metal experiments showed that the subcritical neutron multiplication factor, k/sub eff/, could be determined using point kinetics without any correction for spatial effects from measurements with the source and detectors located adjacent to the same cylinder, whereas for source-detector configurations with either the source and/or detectors adjacent to different cylinders, a model which incorporates the coupling is required to ...
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated ...
This report summarizes the major activities conducted in the Chemical and Energy Research Section of the Chemical Technology Division at Oak Ridge National Laboratory (ORNL) during the period October--December 1997. The section conducts basic and applied research and development in chemical engineering, applied chemistry, and bioprocessing, with an emphasis on energy-driven technologies and advanced chemical separations for nuclear and waste applications. The report describes the various tasks performed within six major areas of research: Hot Cell Operations, Process Chemistry and Thermodynamics, Separations and Materials Synthesis, Fluid Structure and Properties, Biotechnology Research, and Molecular Studies. The name of a technical contact is included with each task described, and readers are encouraged to contact these individuals if they need additional information. Activities conducted within the area of Hot Cell Operations included efforts to optimize the processing conditions ...
A method for determining the reactivity of highly subcritical systems of fissile material, using neutron-noise power spectral densities in conjunction with a /sup 252/Cf source, had previousy been tested in two fast reactor critical assemblies (a mockup of the Fast Flux Test Facility reactor and unreflected enriched uranium metal assemblies) and one thermal reactor (a light-water moderated and reflected lattice of Oak Ridge Research Reactor fuel elements). The last-mentioned test demonstrated the effectiveness of the method in water-moderated systems and thereby prompted the present study of its application to facilities for fuel preparation, reprocessing, and storage. To investigate the applicability of this method to facilities for fuel preparation, reprocessing, and storage, limited experiments were performed with a uranyl fluoride solution. The Los Alamos National Laboratory SHEBA facility, an unreflected cylindrical tank (56 cm diam), was partially filled with ...