Possible explosive compounds in the Savannah River Site waste tank farm facilities
Energy Technology Data Exchange (ETDEWEB)
This report will be revised upon completion of current testing investigating the radiolytic stability of additional energetic materials and the analysis of tank farm samples for volatile and semi-volatile organic compounds.
2000-04-13
UK PubMed Central (United Kingdom)
BackgroundAgricultural practices such as the use of irrigation during rice cultivation, the use of ponds for fish farming and the storage of water in tanks for livestock provide...Full Text Available
Inventory of Tank Farm equipment stored or abandoned aboveground
Energy Technology Data Exchange (ETDEWEB)
This document provides an inventory of Tank Farm equipment stored or abandoned aboveground and potentially subject to regulation. This inventory was conducted in part to ensure that Westinghouse Hanford Company (WHC) does not violate dangerous waste laws concerning storage of potentially contaminated equipment/debris that has been in contact with dangerous waste. The report identifies areas inventoried and provides photographs of equipment.
1994-10-12
Energy Technology Data Exchange (ETDEWEB)
The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Document (S/RID) is contained in multiple volumes. This document (Volume 2) presents the standards and requirements for the following sections: Quality Assurance, Training and Qualification, Emergency Planning and Preparedness, and Construction.
1994-04-01
Operational test report integrated system test (ventilation upgrade)
Energy Technology Data Exchange (ETDEWEB)
Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.
1999-10-05
Absorption of carbon dioxide in waste tanks
International Nuclear Information System (INIS)
Air flow rates and carbon dioxide concentrations of air entering and exiting eight H-Area waste tanks were monitored for a period of one year. The average instanteous concentration of carbon dioxide in air is within the range reported offsite, and therefore is not affect by operation of the coal-fired power plant adjacent to the tank farm. Waste solutions in each of the tanks were observed to be continuously absorbing carbon dioxide. The rate of absorption of carbon dioxide decreased linearly with the pH of the solution. Personnel exposure associated with the routine sampling and analysis of radioactive wastes stored at SRP to determine the levels of corrosion inhibitors in solution could be reduced by monitoring the absorption of carbon dioxide and using the relationship between pH and carbon dioxide absorption to determine the free hydroxide concentration in solution.
1987-09-01
C-106 tank process ventilation test
Energy Technology Data Exchange (ETDEWEB)
Project W-320 Acceptance Test Report for tank 241-C-106, 296-C-006 Ventilation System Acceptance Test Procedure (ATP) HNF-SD-W320-012, C-106 Tank Process Ventilation Test, was an in depth test of the 296-C-006 ventilation system and ventilation support systems required to perform the sluicing of tank C-106. Systems involved included electrical, instrumentation, chiller and HVAC. Tests began at component level, moved to loop level, up to system level and finally to an integrated systems level test. One criteria was to perform the test with the least amount of risk from a radioactive contamination potential stand point. To accomplish this a temporary configuration was designed that would simulate operation of the systems, without being connected directly to the waste tank air space. This was done by blanking off ducting to ...
1998-07-20
Projected radionuclide inventories of DWPF glass from current waste at time of production
Energy Technology Data Exchange (ETDEWEB)
The Waste Acceptance Preliminary Specifications (WAPS) require that the DWPF estimate the inventory of long-lived radionuclides present in the waste glass, and report the values in the Waste Form Qualification Report. In this report, conservative (biased high) estimates of the radionuclide inventory of glass produced from waste currently in the Tank Farm are provided. In most cases, these calculated values compare favorably with actual data. In those cases where the agreement is not good, the values reported here are conservative.
1993-02-04
Energy Technology Data Exchange (ETDEWEB)
This document, the Standards/Requirements Identification Document (S/RID) Phase I Assessment Report for the subject facility, represents the results of an Administrative Assessment to determine whether S/RID requirements are fully addressed by existing policies, plans or procedures. It contains; compliance status, remedial actions, and an implementing manuals report linking S/RID elements to requirement source to implementing manual and section.
1996-09-30
Energy Technology Data Exchange (ETDEWEB)
Five corrosion probes were received from West Valley Nuclear Services for evaluation in simulated tank 8D-2 3rd-stage sludge wash slurry. The same waste slurry simulated was also used in a series of ongoing corrosion studies assessing the effects of in-tank sludge washing on the integrity of tank 8D-2. Two of the corrosion probes were installed in the coupon corrosion test vessels operating at {approximately}150{degrees}F to compare performance of the probes with that observed by coupon tests conducted in the same vessels. Corrosion rate data calculated from electrical resistance measurements of the corrosion probes were evaluated for this study using two slightly different approaches. One approach uses the total length of exposure of the probe to give a ``time-averaged`` value of the corrosion rate. The other approach uses a shorter period of time (relative to the length of the test) in the calculation of corrosion rate, ...
1994-07-01
Natural gas use in Saskatchewan hog industry
Energy Technology Data Exchange (ETDEWEB)
A study was conducted to examine the energy consumption in existing and new hog farming facilities and to analyse the potential for increased natural gas use in the Saskatchewan hog industry. Existing heating/cooling, ventilation and feed mill equipment choices offer possibilities for running on electricity, natural gas or propane. Energy costs are lowest when natural gas is used. To put the study in context, an overview of the Saskatchewan hog industry was provided. The potential increase in natural gas use in hog production by year 2005 was estimated. 10 refs., 6 tabs., 8 figs.
1996-11-01
Liquid radioactive waste discharges from B plant to cribs
Energy Technology Data Exchange (ETDEWEB)
This engineering report compiles information on types and quantities of liquid waste discharged from B-Plant directly to cribs, ditches, reverse wells, etc., that are associated with B-Plant. Waste discharges to these cribs via overflow form 241-B, 241-BX, and 241-BY tank farms, and waste discharged to these cribs from sources other than B-Plant are discussed.Discharges from B-Plant to other cribs, unplanned releases, or waste remaining in tanks are not included in the report. Waste stream composition information is used to predict quantities of individual chemicals sent to cribs. This provides an accurate mass balance of waste streams from B-Plant to these cribs. These predictions are compared with known crib inventories as a verification of the process.
1996-05-29
Energy Technology Data Exchange (ETDEWEB)
The Waste Acceptance Preliminary Specifications (WAPS) require that the DWPF estimate the inventory of long-lived radionuclides present in the waste glass, and report the values in the Waste Form Qualification Report. In this report, conservative (biased high) estimates of the radionuclide inventory of glass produced from waste currently in the Tank Farm are provided. In most cases, these calculated values compare favorably with actual data. In those cases where the agreement is not good, the values reported here are conservative.
1993-02-04
Simulation and design of membrane plants with AspenPlus
Energy Technology Data Exchange (ETDEWEB)
In this paper the simulation of hybrid processes containing membrane units will be discussed. For this purpose a user-defined module for simulation and design of membrane processes was implemented into the simulation program AspenPlus. The advantages can be summarized as follows: - any combination of membrane processes with all other units already implemented in AspenPlus is possible, including internal recycle streams, - utilization of the physical property models and data bases of AspenPlus is possible, - cost and sensitivity analysis can be performed. These benefits are demonstrated in detail for a membrane vapor recovery unit for the treatment of tank farm off-gas, for a two-stage reverse osmosis plant for organic/-organic separations and for a combination of distillation and pervaporation for the separation of a dimethylcarbonate/methanol mixture. (orig.)
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
Waste Management Area U (WMA U) includes the U Tank Farm, is currently regulated under RCRA interim-status regulations, and is scheduled for closure probably post-2030. Groundwater monitoring has been under an evaluation program that compared general contaminant indicator parameters from downgradient wells to background values established from upgradient wells. One of the indicator parameters, specific conductance, exceeded its background value in one downgradient well triggering a change from detection monitoring to a groundwater quality assessment program. The objective of the first phase of this assessment program is to determine whether the increased concentrations of nitrate and chromium in groundwater are from WMA U or from an upgradient source. Based on the results of the first determination, if WMA U is not the source of contamination, then the site will revert to detection monitoring. If WMA U is the source, then a second part of the ...
2000-03-21
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to assess the energy flux and energetic balance related to the swine production and the recycling of residues generated by the system for utilization as organic fertilizers. The experiment was carried out at Vale dos Ipes Farm, located in the city of Ouro Verde do Oeste, in the Western of Parana State. One finishing phase swine unity containing 600 animals was monitored from January to June 2005. The treatment system is composed by one steel digester with capacity for 50 m{sup 3}, one sedimentation tank, one algae tank and one bio fertilizer storage tank. The swine barn cleaning is performed by dry scratching on a daily basis. The generated residues flow by gravitation through ducts towards the digester. The duration of the hydraulic retention period was 12 days. In the calculation of energetic efficiency, the energetic component ration is the greatest energetic cost in ...
2006-07-01
Closure Report for Corrective Action Unit 543: Liquid Disposal Units, Nevada Test Site, Nevada
Energy Technology Data Exchange (ETDEWEB)
This Closure Report (CR) documents closure activities for Corrective Action Unit (CAU) 543, Liquid Disposal Units, according to the Federal Facility Agreement and Consent Order (FFACO, 1996) and the Corrective Action Plan (CAP) for CAU 543 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2007). CAU 543 is located at the Nevada Test Site (NTS), Nevada (Figure 1), and consists of the following seven Corrective Action Sites (CASs): CAS 06-07-01, Decon Pad; CAS 15-01-03, Aboveground Storage Tank; CAS 15-04-01, Septic Tank; CAS 15-05-01, Leachfield; CAS 15-08-01, Liquid Manure Tank; CAS 15-23-01, Underground Radioactive Material Area; CAS 15-23-03, Contaminated Sump, Piping; and CAS 06-07-01 is located at the Decontamination Facility in Area 6, adjacent to Yucca Lake. The remaining CASs are located at the former U.S. Environmental Protection Agency (EPA) ...
2008-01-01
SIMV: An Application of Mathematical Modeling in Ventilator Management
UK PubMed Central (United Kingdom)
SIMV (simulation and modeling of ventilation) is a quantitative system for the mathematical modeling and simulation of pulmonary...Full Text Available
1989-11-08
ICPP water inventory study project summary report
Energy Technology Data Exchange (ETDEWEB)
The Idaho Chemical Processing Plant (ICPP) Water inventory Study was initiated in September 1993 with the formation of a joint working group consisting of representatives from DOE-ID, State of Idaho INEL Oversight Program, US Geological Survey, and INEL employees to investigate three issues that had been identified by the INEL Oversight Program at ICPP: (1) the water inventory imbalance at ICPP, (2) the source of water infiltrating into the Tank Farm vault sumps, and (3) the source of water providing potential recharge to perched water bodies underlying ICPP. These issues suggested that water was being lost from the ICPP distribution system. The INEL Oversight Program was concerned that the unaccounted for water at ICPP could be spreading contaminants that have been released over the past 40 years of operations of ICPP, possibly to the Snake River Plain Aquifer. This report summarizes the findings of each of the component investigations that ...
1994-01-01
Energy Technology Data Exchange (ETDEWEB)
This conference is composed of 21 communications and 21 posters in the domain of building ventilation and indoor air quality; the main themes are: indoor air quality assessment and optimization; performance enhancement and optimization of ventilation systems and equipment; ventilation systems for renovated and rehabilitated buildings; French and European regulations, standardizations and certifications; experimental and numerical simulation studies concerning ventilation systems, air flow, temperature distribution, air quality, thermal comfort and ventilation-induced acoustic levels
1995-10-01
Gas fired heaters and ventilation system improve indoor air quality and thermal comfort
Energy Technology Data Exchange (ETDEWEB)
Rotex Inc. has designed and manufactured industrial sifting equipment since 1844. This site (an existing industrial facility) encompasses approximately 140,000 ft[sup 2] (13,006 m[sup 2]) of offices, R D shops, assembly and storage areas, as well as a large welding shop that was the main focus of this project. This facility consists of three separate buildings that are all connected and open to one another. The original building dates from 1908. The newest addition (32,400 ft[sup 2]; 3,010 m[sup 2]) was added in 1977, and is referred to as the 77 Building. This building was initially equipped with oil fired heating equipment due to the moratorium on new gas sales that was in effect at that time. This project was driven by the client's need to remove underground oil storage tanks to comply with environmental standards. This article describes the 77 Building conversion from oil to an environmentally cleaner fuel, natural gas. Existing heaters were removed ...
1994-03-01
Tank waste remediation system retrieval and disposal mission key enabling assumptions
Energy Technology Data Exchange (ETDEWEB)
An overall systems approach has been applied to develop action plans to support the retrieval and immobilization waste disposal mission. The review concluded that the systems and infrastructure required to support the mission are known. Required systems are either in place or plans have been developed to ensure they exist when needed. The review showed that since October 1996 a robust system engineering approach to establishing integrated Technical Baselines, work breakdown structures, tank farm structure and configurations and work scope and costs has been established itself as part of the culture within TWRS. An analysis of the programmatic, management and technical activities necessary to declare readiness to proceed with execution of the mission demonstrates that the system, people and hardware will be on line and ready to support the private contractors. The systems approach included defining the retrieval and immobilized waste disposal ...
1998-01-05
Nomographs estite floating-roof tank evaporation
Energy Technology Data Exchange (ETDEWEB)
Nomographs are presented that estimate the evaporation loss from external floating-roof tanks using tank diameter, type of seal, product vapor pressure, and wind velocity.
1986-01-27
Maintaining Tank and Infantry Integration Training
Page 1. Maintaining Tank and Infantry Integration Training ... 4. TITLE AND SUBTITLE Maintaining Tank and Infantry Integration Training 5a. ...
2005-01-11
Survival in Patients Receiving Prolonged Ventilation: Factors that Influence Outcome
UK PubMed Central (United Kingdom)
Background:Prolonged mechanical ventilation is increasingly common. It is expensive and associated with significant morbidity and mortality. Our objective is to comprehensively characterize...Full Text Available
Combustible Metallic Igniter Casing for Tank Guns
... TANK GUNS, GUNS, CHAMBERS, IGNITERS, INTERIOR BALLISTICS, INTERNAL PRESSURE, COMBUSTIBLE CARTRIDGE CASES, METALS. ...
1991-11-01
Energy Technology Data Exchange (ETDEWEB)
This CD-Rom edited by the French scientific and technical committee of the space heating, ventilation and air-conditioning industry (CoSTIC) presents a series of technical files about ventilation and space heating systems with several references to the current regulatory texts. Modifications of the original legislative texts have been integrated to the original texts for a more comfortable reading. Search is performed using diagrams and key-words. (J.S.)
2000-06-01
Power fluidics for ventilation control
International Nuclear Information System (INIS)
... amplification exhaust systems fluidic control devices gloveboxes pressure
1984-11-28
CleverFarm - A SuperSCADA system for wind farms
Energy Technology Data Exchange (ETDEWEB)
The CleverFarm project started out to build an integrated monitoring system for wind farms, where all information would be available and could be used across the wind farm for maintenance and component health assessments. This would enable wind farm operators to prioritise their efforts, since they have a good view of the farm status from home. A large emphasis was placed on the integration of condition monitoring approaches in the central system, enabling estimates of the remaining lifetime of components, especially in the nacelle. During the 3,5 years of the project, software and hardware was developed and installed in two wind farms in Denmark and Germany. The connected hardware included two different condition monitoring systems based on vibration sensors from Gram&Juhl and ISET, plus a camera system developed by Overspeed. Additionally, short-term ...
2004-08-01
Environmental Research Database
DescriptionFarm-level estimates of the financial impact of regulation are important indicators of the effect that a regulation have. Such estimates should be included in RIA, particularly within the Small Firms Impact Test. This farm-level analysis can be used in the RIA to inform judgements of the affordability of the regulation proposal. It will help to identify which farm types are likely to be financially had-hit from the regulation. Farm-level cost estimates for each regulation are also required t [continued...
2007-01-23
An investigation of passive ventilation cooling and control strategies for an educational building
Energy Technology Data Exchange (ETDEWEB)
Many non-domestic buildings, built recently in the UK, use natural means to provide ventilation for indoor air quality and thermal comfort. This paper presents monitoring results obtained from such a purpose built naturally ventilated educational building. Its performance during the summer is discussed based on monitored results. Using thermal and ventilation modelling, the paper also discusses the optimisation of the building's summer performance. Recommendations on the selection of appropriate ventilation strategies in relation to the prevailing external conditions are derived and the appropriateness of the control methods is discussed. (author)
2001-02-01
Criticality safety review of FFTF interim decay storage tank
The Interim Decay Storage tank (IDS) will be located in a concrete cell in the FFTF reactor building. The tank will have capacity to store 112 driver fuel assemblies and 10 test assemblies in sodium. A criticality safety analysis for the design of the IDS tank was performed. From the analysis, it is concluded that under normal operating conditions and minor abnormal conditions that might shift the fuel, the IDS tank will remain adequately subcritical. (auth)
1975-10-01
Energy Technology Data Exchange (ETDEWEB)
The indoor climate of school buildings have been much debated recently. Many problems connected with air quality and thermal comfort are caused by bad maintenance, fitted carpets and no sunshades. Mechanical ventilation in schools has gained a bad reputation and many municipalities are seeking other solutions when building new schools. Natural ventilation according to the ''Swedish model'' does not use air filters or heat recovery from the outgoing air and achieve low energy consumption by reducing the airflow substantially in cold weather. Most of the naturally ventilated schools have supply air culverts of concrete below ground outside the building and in the basement. This is also true of schools using hybrid ventilation, where natural and mechanical ventilation is combined. The naturally ventilated schools often use manual ...
2000-07-01
Energy Technology Data Exchange (ETDEWEB)
The structural acceptance criteria contained herein for the evaluation of existing underground double-shell waste storage tanks located at the Hanford Site is part of the Life Management/Aging Management Program of the Tank Waste Remediation System. The purpose of the overall life management program is to ensure that confinement of the waste is maintained over the required service life of the tanks. Characterization of the present condition of the tanks, understanding and characterization of potential degradation mechanisms, and development of tank structural acceptance criteria based on previous service and projected use are prerequisites to assessing tank integrity, to projecting the length of tank service, and to developing and applying prudent fixes or repairs. The criteria provided herein summarize the requirements for the analysis and ...
1995-09-01
Energy Technology Data Exchange (ETDEWEB)
In parking areas of large extent, the removal of engine exhaust gases, especially of their CO gas components with ventilation plant is mainly done by transverse ventilation over short paths. By their presence, the ventilation ducts required for this purpose often reduce the value of the parking space by restrictions with a consequent reduction of their acceptance by the users. Longitudinal ventilation without ducts can be a remedy in such cases. Depending on the required room air quality in the zones of highest loading, the volume flows with longitudinal removal are no greater than with conventional transverse ventilation. This article is concerned with the different methods of operation of the two systems. (orig./BWI)
1994-04-01
Decontamination of spent fuel dissolution tank
International Nuclear Information System (INIS)
The decontamination of the dissolution tank from spent fuel reprocessing out-ling device is studied, by using FL-AP decontamination agent. The decontamination factor per step is 2.2, 2.4, respectively for #alpha#, #beta# activities. After dissecting the tank, residual contamination in inner surface of the tank was found to be non-uniform. The exact original contamination value of the tank surface could be approximated by calculating the total amounts of radionuclide distributed on the hanging specimens, the dissecting specimen, and radioactive level in waste decontamination agent. Therefore, it can be concluded that the hanging specimens method is feasible for measuring the decontamination factor of spent fuel dissolution tank. (authors)
2006-01-01
UK PubMed Central (United Kingdom)
The study involved 110 randomly selected dairy farms located in the Ontario, Canada counties of Bruce, Grey, Huron, Oxford, Perth, Waterloo and Wellington. Herds were classified as "intensive" and "extensive"....Full Text Available
1986-01-01
UK PubMed Central (United Kingdom)
The purpose of this study was to assess changes in dairy herd milk production and milk composition associated with changes in Salmonella contamination of bulk milk on dairy farms in southwestern Ontario....Full Text Available
1989-04-01
UK PubMed Central (United Kingdom)
A multidisciplinary approach was used to study the effects of pollution from a marine fish farm on nitrification rates and on the community structure of ammonia-oxidizing bacteria in the underlying...Full Text Available
1999-01-01
UK PubMed Central (United Kingdom)
AbstractA newly recognized syndrome, characterized by sudden death of farmed deer that are in good to excellent nutritional condition, with lesions of small intestinal mucosal hemorrhage...Full Text Available
2005-08-01
Farm-level risk factors for the presence of Salmonella in 89 Alberta swine-finishing barns
UK PubMed Central (United Kingdom)
This study investigated potential risk factors for the presence of Salmonella on 89 Alberta swine-finishing farms with the use of a questionnaire. Salmonella status...Full Text Available
2007-10-01
UK PubMed Central (United Kingdom)
A total of 295 ceftiofur-resistant Escherichia coli isolates were obtained from 489 cloacal samples collected at five different Belgian broiler farms with the aim to evaluate the diversity...Full Text Available
2008-04-01
Ak-Chin Indian Community Biomass Feasiiblity Study
Energy Technology Data Exchange (ETDEWEB)
Study of the conversion of chicken litter to biogas for the production of energy. There was an additional requirement that after extracting the energy from the chicken litter the nutrient value of the raw chicken litter had to be returned to the Ak-Chin Farms for use as fertilizer in a form and delivery method acceptable to the Farm.
2005-12-31
Ventilated Improved Pit Latrines: Recent Developments in Zimbabwe.
Contents: Ventilated improved pit latrines; (General description, odor control, insect control); Zimbabwean VIP latrine designs; (Latrine entrance, ferrocement spirals, rural spirals, training and education, design transfer).
1982-01-01
Carbon Monoxide Protects against Ventilator-induced Lung Injury via PPAR-? and Inhibition of Egr-1
UK PubMed Central (United Kingdom)
Rationale: Ventilator-induced lung injury (VILI) leads to an unacceptably high mortality. In this regard, the antiinflammatory properties of inhaled carbon monoxide (CO) may provide...Full Text Available
2008-06-01
Hazardous Waste Management on the Farm
Sep 2, 2008 ... Abstract: This tutorial is intended to serve as a guide towards proper hazardous waste management. Knowing the regulations, different ...
Energy Technology Data Exchange (ETDEWEB)
This short article discusses the results of a market survey on ventilation systems for residential buildings and the role played by ventilation systems in our daily lives. Problems incurred as a result of insufficient ventilation conditions such as the formation of mould in dwellings whose windows have been replaced with better seals are discussed, for example. The negative image of air-conditioning and its causes are examined. The need for action in this area is stressed. Further findings of the study are presented, including a detailed review of current equipment and scenarios on how these systems can develop in the future. The extension of the study to cover the situation in further European countries is mentioned.
2003-07-01
International Nuclear Information System (INIS)
Various remedial measures have been tried to lower radon levels in buildings in Uranium City. The methods used are source material removal, passive ventilation of crawl spaces, sub-floor ventilation, complete epoxy coating of the entire basement, sealants for floor-wall joints and cracks in basements, electrostatic precipitators, mechanical ventilation, and sealing and grouting concrete block plenums in basement walls. The type and condition of structures encountered in Uranium City as well as the relative isolation of the town indicate that mechanical ventilation is the most long-term cost-effective method.
1980-03-12
Multicriteria analysis of ventilation in summer period
Energy Technology Data Exchange (ETDEWEB)
This paper presents a multicriteria analysis of ventilation during summertime in Europe. Multicriteria analysis theories are used to determine the most suitable ventilation strategy on a university building, that is to say to ensure the best possible indoor air quality, thermal comfort of the occupants and the lower energy consumption in case of accelerated diurnal or nocturnal ventilation and/or air conditioning. After defining the possible actions, the criteria of quality regarding thermal comfort, indoor air quality and energy consumption are defined. The possible actions are then assessed relative to each of these three criteria and ranked from the best to the worst ones using two different multicriteria analysis methods. (author)
2002-02-01
A study described part-time and small farmers (PT/SF) on the basis of their demographic characteristics and determined their farm management educational needs. Findings revealed that the majority of the PT/SF were males who operated farms of 50-150 acres for 11 or more years, were 35-44 years of age, and were high school graduates who principally produced crops. The four areas of farm management education needed by PT/SF were farm tax management, marketing farm products, determining farm insurance needs, and farm recordkeeping. Findings regarding a third objective--to determine the relationship between the selected demographic charcteristics and the computed farm management educational needs of PT/SF--revealed a range of negligible to substantial relationships. The moderate to substantial positive relationships existed ...
1986-12-01
Energy Technology Data Exchange (ETDEWEB)
In 1994, after four years of preparation, the first off-shore wind farm in the Netherlands was erected. The ``Lely`` wind farm comprises four NedWind 500 kW wind turbines, of rotor diameter 40.77 m. The turbines are placed on unique single-pile foundations. An interesting engineering aspect of the project is the interaction between the foundations and the turbine. (author)
1996-09-01
Energy and greenhouse gas emissions of Australian cotton : from field to fabric
Energy Technology Data Exchange (ETDEWEB)
This paper reported on a study in which a life cycle assessment (LCA) of cotton production in Australia was conducted to evaluate energy use and greenhouse gas (GHG) emissions from tillage to export shipping. The study showed that on-farm indirect cotton-farming is the most energy consuming component, consuming nearly 32.36 GJ/ha of energy. On-farm indirect cotton-farming is the most GHG emitting component, emitting about 1.64 tonne of carbon dioxide (CO{sub 2})/ha. Energy use and the emissions by off-farm direct cotton-farming were calculated as 5.09 GJ/ha and 0.14 tonne CO{sub 2}/ha respectively. Energy consumed by off-farm indirect farming was found to be 0.036 GJ/ha or 0.002 tonne CO{sub 2}/ha. The total energy usage and greenhouse gas emissions in the Australian cotton farming system were ...
2010-07-01
Ventilation of Ukrainian mines and its improvement
Energy Technology Data Exchange (ETDEWEB)
Mining depth in coal basins of the Ukrainian SSR increases by 12 to 18 m/year and ventilation conditions become more complicated due to increasing methane content in coal seams and hazards of coal spontaneous combustion. Over 87% of Ukrainian coal mines is characterized by methane or carbon dioxide content. In some gassy mines gas emission is as high as 173 m/SUP/3/min. Length of ventilation tunnels in Ukrainian coal mines ranges from 2.1 to 15 km and the average length amounts to 7.3 km. In underground mines of the Ukrainian SSR 730 blowers are used: 61% axial flow blowers and 39% centrifugal blowers. The following blower types are most popular: the VOKD-1.5, VOKD-1.8, VODK-2.4, VTs-25, VTs-32 and VTsD-2.2. Ventilation network of Ukrainian mines consists of 1904 coal faces and 3125 development workings. Ventilation systems used in mines are shown in 2 schemes. Trends in ventilation ...
1982-04-01
The feasibility of using a septic tank as a heat source for geothermal heat pumps
Energy Technology Data Exchange (ETDEWEB)
A geothermal heat pump (GHP) system with three ground coils was installed in a residence in northern Idaho with a portion of the ground heat exchanger wrapped around the residential septic tank. The septic coil provided a significant portion of the heating for the residence over the heating season. There was no evidence of the septic tank freezing up or failing to properly function. Utilizing a septic tank as a heat source for GHP systems is feasible design option if the septic tank is used on a full-time basis. However, the tank should be surrounded on all sides by a large amount of soil and/or insulated from the ground surface to ensure that ground temperatures near the tank remain warm during the winter.
1999-11-01
Energy Technology Data Exchange (ETDEWEB)
Unlike the conventional automotive, modem railway trains are designed with non-openable windows; and a mechanical ventilation and air-conditioning (MVAC) system is installed in each train compartment for better indoor air quality as well as to provide a thermally comfortable environment. The ventilation rate is no doubt a critical element in the design of a MVAC system, especially in Hong Kong where the daily passenger load is extremely heavy. Earlier studies illustrated that carbon dioxide can be controlled at 1000 ppm by increasing the ventilation rate to 25.2 m{sup 3} h{sup -1}; however, it will also lead to an increase in energy consumption. In this paper, the electrical energy consumption at various ventilation rates was studied, and the cost of maintaining a low carbon dioxide level was estimated These provide solid information for the local railway companies to improve the air quality inside the ...
2000-01-01
Energy Technology Data Exchange (ETDEWEB)
With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to air quality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)
1993-07-01
International Nuclear Information System (INIS)
Two different techniques were used for measuring Rn-gas concentrations and Working Level (WL) in U-exploration galleries at El-Allouga Mine, Sinai, Egypt. The active techniques used EDA(RDA-200) with calibrated Lucas cell and Tri-Met-372 instruments and passive techniques used four different types of SSNTD. Twenty eight (28) stations inside the studied tunnels were located covering the different environmental conditions. The measurements were carried out during summer time, in the ventilated sector (16 stations), the average tunnel air temperature was 24.4 #+-# 2.2 degree C and relative humidity 38%. In the non-ventilated sector (12 stations), the average tunnel air temperature was 22.2#+-#0.4 degree C and relative humidity 70%. The Rn-gas concentrations using EDA(RDA-200) and calibrated Lucas cell, in the ventilated sector averaged 11.966 p Ci/l, while in the non-ventilated stations averaged 786.21 p ...
2007-04-22
Energy Technology Data Exchange (ETDEWEB)
A complete analysis is performed to simulate biomass production incorporated into a realistic whole farm situation, including or replacing a typical crop mix. Representative farms are constructed to accommodate such simulation. Four management systems are simulated for each firm, with each simulation depicting a different crop mix and/or use of different farming technologies and production methods. The first simulation was a base farm plan in which the operator would maintain the historical crop mix for the area, participate in all price support programs, and not participate in either a conservative reserve or a biomass production program. In the second simulation, the operator would again maintain the historical crop mix, would not participate in a conservation reserve or biomass production program, and would be ineligible to participate in any price support system. The third simulation introduced the ...
1992-01-01
Development of a farm-firm modelling system for evaluation of herbaceous energy crops
Energy Technology Data Exchange (ETDEWEB)
A complete analysis is performed to simulate biomass production incorporated into a realistic whole farm situation, including or replacing a typical crop mix. Representative farms are constructed to accommodate such simulation. Four management systems are simulated for each firm, with each simulation depicting a different crop mix and/or use of different farming technologies and production methods. The first simulation was a base farm plan in which the operator would maintain the historical crop mix for the area, participate in all price support programs, and not participate in either a conservative reserve or a biomass production program. In the second simulation, the operator would again maintain the historical crop mix, would not participate in a conservation reserve or biomass production program, and would be ineligible to participate in any price support system. The third simulation introduced the ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
Abstract: The Hanford Tanks Initiative (HTI) is a five-year project resulting from the technical and financial partnership of the U.S. Department of Energy`s Office of Waste Management (EM-30) and Office of Science and Technology Development (EM-50). The HTI project accelerates activities to gain key technical, cost performance, and regulatory information on two high-level waste tanks. The HTI will provide a basis for design and regulatory decisions affecting the remainder of the Tank Waste Remediation System`s tank waste retrieval Program.
1997-07-01
2007 SB14 Source Reduction Plan/Report
Energy Technology Data Exchange (ETDEWEB)
Aqueous solutions (mixed waste) generated from various LLNL operations, such as debris washing, sample preparation and analysis, and equipment maintenance and cleanout, were combined for storage in the B695 tank farm. Prior to combination the individual waste streams had different codes depending on the particular generating process and waste characteristics. The largest streams were CWC 132, 791, 134, 792. Several smaller waste streams were also included. This combined waste stream was treated at LLNL's waste treatment facility using a vacuum filtration and cool vapor evaporation process in preparation for discharge to sanitary sewer. Prior to discharge, the treated waste stream was sampled and the results were reviewed by LLNL's water monitoring specialists. The treated solution was discharged following confirmation that it met the discharge criteria. A major source, accounting for 50% for this waste stream, is metal ...
2007-07-24
Phase Chemistry of Tank Sludge Residual Components
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) has millions of gallons of high level nuclear waste stored in underground tanks at Hanford, Washington and Savannah River, South Carolina. These tanks will eventually be emptied and decommissioned. This will leave a residue of sludge adhering to the interior tank surfaces that may contaminate nearby groundwaters with radionuclides and RCRA metals. Performance assessment (PA) calculations must be carried out prior to closing the tanks. This requires developing radionuclide release models from the sludges so that the PA calculations can be based on credible source terms. These efforts continued to be hindered by uncertainties regarding the actual nature of the tank contents and the distribution of radionuclides among the various phases. In particular, it is of vital importance to know what radionuclides are associated with solid sludge components. ...
2002-04-02
Phase chemistry and radionuclide retention of high level radioactive waste tank sludges
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) has millions of gallons of high level nuclear waste stored in underground tanks at Hanford, Washington and Savannah River, South Carolina. These tanks will eventually be emptied and decommissioned. This will leave a residue of sludge adhering to the interior tank surfaces that may contaminate groundwaters with radionuclides and RCRA metals. Experimentation on such sludges is both dangerous and prohibitively expensive so there is a great advantage to developing artificial sludges. The US DOE Environmental Management Science Program (EMSP) has funded a program to investigate the feasibility of developing such materials. The following text reports on the success of this program, and suggests that much of the radioisotope inventory left in a tank will not move out into the surrounding environment. Ultimately, such studies may play a significant role in developing safe and ...
2000-05-19
Energy Technology Data Exchange (ETDEWEB)
The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.
1995-09-01
Designed primarily for Missouri vocational agricultural instructors participating in the Farm Business Management Analysis Program, this instructor's guide, consisting of 10 lessons, deals with adjusting a farm business to increase profits. The following topics are covered in the individual lessons: law and the farm family, planning income tax management, closing the record book and planning cash flow, evaluating family living expenses, determining the most profitable livestock enterprise, determining the most profitable cropping system, planning the farm marketing program, adjusting capital investments to increase net profit, planning for efficient labor use, and controlling costs. Included in each section are suggestions for a review of previous materials covered, an objective, motivational techniques, key points to be addressed in the lesson, information to be introduced during the lesson, ...
1982-06-01
Use of multipurpose trees in hill farming systems in western Nepal
Energy Technology Data Exchange (ETDEWEB)
A study of two villages identified 55 woody perennial species that are maintained in contour strips across slopes and around fields in a subsistence farming system. These trees and shrubs produced fodder and firewood and reduced erosion hazards, allowing crop production on very steep slopes where it would otherwise be very difficult. Data on basic farm management, production of crops, etc. are discussed. The performance of the system is assessed and its strengths and weaknesses highlighted. It is suggested that several locally available medicinal plants could be incorporated into the system.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
Ventilation systems must ensure high room air quality with minimum energy consumption in all states of operation. Systems for ventilation on demand are increasing their market share. (orig./MSK) [Deutsch] Oberste Aufgabe von Raumlufttechnischen Anlagen ist die Sicherstellung guter Raumluftqualitaet bei minimalem Energieverbrauch unter allen Betriebsbedingungen. Um dieses Ziel zu erreichen, setzt sich am Markt zunehmend die bedarfsgeregelte Lueftung durch. (orig./MSK)
1997-11-01
Ventilation by the windows in classrooms: a case study
Energy Technology Data Exchange (ETDEWEB)
Four classrooms of two secondary schools located around Lyon in France have been monitored. The objectives are to analyse the quality of the indoor air and the thermal comfort and also the behaviour of the occupants towards opening of the windows. This paper briefly describes the context and the nature of the monitoring campaign, and presents the results of the measurements with direct interpretation of the ventilation needs. Results from this study show that allowable CO{sub 2} levels are overpassed several times in a school day. The presence of a mechanical ventilation system leads to lower peaks but the fresh airflow is too small to prevent an indoor confining, that is also revealed by the aerobiological analysis. (author)
1994-12-31
New radioisotope for lung ventilation studies: 19-neon
Energy Technology Data Exchange (ETDEWEB)
Neon 19, a 17-second positron-emitting radioelement, is produced continously by 23 MeV alpha particle bombardment of oxygen. For a 12 ..mu..A particle current the method of preparation described delivers 14 mCi of neon 19 per min to the functional exploration room. The radiochemically pure radioactive gas is diluted in air and breathed continously by the patient lying under a positron tomographic camera. The regional lung ventilation distribution is obtained on 2 cm thick sections of organ with a transverse resolution of 17 mm. Quantification of the ventilation output per unit lung volume is contemplated.
1980-10-01
Energy Technology Data Exchange (ETDEWEB)
This article deals with the need for control strategies and control systems in buildings with hybrid ventilation. In this respect, control strategies are methods of keeping certain parameters like temperature, air quality etc within specified limits. A control system is automatic and includes sensors, motors, dampers etc. The article also discusses consequences with respect to thermal comfort, air quality and energy use following selection of control parameters for controlling air masses.
2001-07-01
The role of contagious disease in udder health
UK PubMed Central (United Kingdom)
Contagious diseases are a threat to animal health and productivity, both nationally and at the farm level. This makes implementation of biosecurity measures to prevent their introduction and...Full Text Available
2009-10-01
Evaluation of enteric methane prediction equations for dairy cows used in whole farm models
British Library Electronic Table of Contents (United Kingdom)
Abstract The importance of evaluating greenhouse gas (GHG) emissions from dairy cows within the whole farm setting is being realized as more important than evaluating these emissions in isolation. Current whole farm models aimed at evaluating GHG emissions make use of simple regression equations to predict enteric methane (CH4) production. The objective of the current paper is to evaluate the performance of nine CH4 prediction equations that are currently being used in whole farm GHG models. Data used to evaluate the prediction equations came from a collection of individual (IND) and treatment averaged (TRT) data. Equations were compared based on mean square prediction error (MSPE) and concordance correlation coefficient (CCC) analysis. In general, predictions were poor, with root MSPE (as...
2010-01-01
Diagnostics of Radionuclides Effects Results
International Science & Technology Center (ISTC)
Development of New Methods and Means of Assessing of Consequences of Radionuclide and Heavy Metal Salt Effect, Criteria of Forecasting Physiological State and Productivity of the Farm Animals under Conditions of Ecological Pollution of Environment
Government policies that encourage exploitation--in particular excessive logging and clearing for ranches and farms--are largely to blame for the accelerating destruction of tropical forests. This paper surveys the problem in detail and briefly recommends potential solutions.
1990-04-01
CFSAN - Questions and Answers on FDA's Import Alert on Farm-Raised ...
... Program on nitrofurans. Nitrofurazone (TR-337 published in June 1988) and Nitrofurantoin (TR-341 published in Sept 1989). Both of ...
Charts give vapor loss from internal floating-roof tanks
Energy Technology Data Exchange (ETDEWEB)
Nomographs have been constructed to estimate the average evaporation loss from internal floating-roof tanks. Loss determined from the charts can be used to evaluate the economics of seal conversion and to reconcile refinery, petrochemical plant, and storage terminal losses. The losses represent average standing losses only. They do not cover losses associated with the movement of product into or out of the tank. The average standing evaporation loss from an internal floating-roof tank depends on: vapor pressure of the product; type and condition of roof seal; tank diameter; and type of fixed roof support. The nomographs can estimate evaporation loss for product true vapor pressures (TVP) ranging from 1.5 to 14 psia, the most commonly used seals for average and tight fit conditions, tank diameters ranging from 50 to 250 ft, welded and bolted designs, and both self-supporting and ...
1987-03-09
Ventilation test at Mont Terri. Geoelectric monitoring of the opalinus clay desaturation. Phase 2
Energy Technology Data Exchange (ETDEWEB)
Between December 2001 and May 2004, a ventilation experiment (VE) was performed in the Mont Terri Underground Research Laboratory (URL) and co-financed by the Commission of the European Communities. The objective was to investigate the desaturation of consolidated clay formations in consequence of the ventilation of underground openings of a repository in such a formation. The results of the geoelectric measurements performed in the second phase of the Mont Terri ventilation test can be summarized as follows: Geoelectric tomography has been found suitable for monitoring ventilation-induced saturation changes in the Opalinus clay. During ventilation with dry air a desaturation down to below 50% could be detected in both desaturation cycles. The desaturated zone extends less than 0.5 m into the rock around the microtunnel. During the second resaturation phase, ...
2008-04-15
Ventilation test at Mont Terri. Geoelectric monitoring of the opalinus clay desaturation. Phase 2
International Nuclear Information System (INIS)
Between December 2001 and May 2004, a ventilation experiment (VE) was performed in the Mont Terri Underground Research Laboratory (URL) and co-financed by the Commission of the European Communities. The objective was to investigate the desaturation of consolidated clay formations in consequence of the ventilation of underground openings of a repository in such a formation. The results of the geoelectric measurements performed in the second phase of the Mont Terri ventilation test can be summarized as follows: Geoelectric tomography has been found suitable for monitoring ventilation-induced saturation changes in the Opalinus clay. During ventilation with dry air a desaturation down to below 50% could be detected in both desaturation cycles. The desaturated zone extends less than 0.5 m into the rock around the microtunnel. During the second resaturation phase, ...
Revisiting an old hypothesis of human thermal perception: alliesthesia
British Library Electronic Table of Contents (United Kingdom)
Many new technologies and approaches to the provision of comfort inside buildings such as displacement ventilation, mixed-mode strategies, personally controllable (task-ambient) designs, chilled beams as well as some old but recently fashionable ones such as natural ventilation are prompting a rethink of the accepted comfort wisdom. How can a single combination of thermal environmental parameters be deemed unacceptable in a conventional heating ventilation and air-conditioning setting, and yet be regarded as acceptable, or even pleasant, in a naturally ventilated or mixed-mode setting? Why do current comfort standards prescribe static and isothermal conditions for comfort in one building, and dynamic and spatially variable indoor climates for comfort in another? The phenomenon of alliesthe...
2011-01-01
Providing better indoor environmental quality brings economicbenefits
Energy Technology Data Exchange (ETDEWEB)
This paper summarizes the current scientific evidence that improved indoor environmental quality can improve work performance and health. The review indicates that work and school work performance is affected by indoor temperature and ventilation rate. Pollutant source removal can sometimes improve work performance. Based on formal statistical analyses of existing research results, quantitative relationships are provided for the linkages of work performance with indoor temperature and outdoor air ventilation rate. The review also indicates that improved health and related financial savings are obtainable from reduced indoor tobacco smoking, prevention and remediation of building dampness, and increased ventilation. Example cost-benefit analyses indicate that many measures to improve indoor temperature control and increase ventilation rates will be highly cost effective, with benefit-cost ratios as high ...
2007-06-01
British Library Electronic Table of Contents (United Kingdom)
Displacement Ventilation (DV) offers a great opportunity to improve indoor air quality while reducing the energy consumption compared to mixing ventilation. A frequent problem with displacement ventilation is however the draft discomfort caused by the cold air movement at foot level and excessive temperature difference between head and ankle. Despite numerous past studies, there is still a lack of detailed data regarding the velocity and temperature distribution inside DV jets. In this experimental study, measurements of the air velocity and temperature are performed in the DV jet produced by a flat wall-mounted DV diffuser, using a fine mesh focused on the 0.00-0.20 m height range. Two supply conditions are studied. Three planes of measurements are covered: the vertical longitudinal plane...
2012-01-01
International Nuclear Information System (INIS)
Full text: Certain groups of patients have been excluded from ventilation lung scanning due to their inability to comply with instruction. Tetley Manufacturing have recently developed a Positive Ventilation Delivery System (PVDS) which assists in delivering Technegas to patients who are unable to cooperate fully. The aim of this study is to evaluate the PVDS in the clinical setting. Fifteen frail aged and psychogeriatric patients (n=l 5), mean age 78 years (range 60-93), were ventilated with Technegas using the PVDS. The decision to ventilate the patient with the PVDS was based on an initial assessment of the patients ability to comply with instructions, or failure of the conventional ventilation method, to produce an adequate count rate. Technegas was prepared in the usual manner and then delivered to the patients lungs by squeezing a black anesthetic bag synchronously with the ...
1998-06-01
Energy Technology Data Exchange (ETDEWEB)
At the request of the US Department of Housing and Urban Development (HUD), the Pacific Northwest Laboratory estimated the material, labor, and operating costs for ventilation equipment needed for compliance with HUD`s proposed revision to the ventilation standard for manufactured housing. This was intended to bound the financial impacts of the ventilation standard revision. Researchers evaluated five possible prototype ventilation systems that met the proposed ventilation requirements. Of those five, two systems were determined to be the most likely used by housing manufacturers: System 1 combines a fresh air duct with the existing central forced-air system to supply and circulate fresh air to conditioned spaces. System 2 uses a separate exhaust fan to remove air from the manufactured home. The estimated material and labor costs for these two systems range from $200 to $300 per ...
1993-11-01
Construction progress of the cooling & ventilation in the LHC project
After the LEP dismantling Phase the Cooling and Ventilation Group has started the LHC construction work. Year 2001 through to 2004 will certainly be the most important period of activity for the CV group in the erection phase The author will report on the current works that are in progress on the different LHC Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work completed in the new surface buildings in Points 1, 4,5,6 and 8. The work for the Cooling plants comprehend to the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, For all of these activities, an updated report of the progress the work, the planning and of the expenses are given. Finally, a brief overview of the future activities is presented.
2002-01-01
Construction Progress of the Cooling and Ventilation in the LHC Project
The Cooling and Ventilation Group has started the LHC construction work in September 1999 and will get into full activity when LEP will be stopped and dismantled: in total 12 major contracts for an amount of about 120 MCHF will be established to build the needed installations for the LHC. The author will report on the current works that are in progress on the different LEP Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work, completed in the new surface buildings in Points 18, is currently held in Points 4 and 5. Point 1 will follow in the near future. The work for the Cooling plants comprehend the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, the buried pipes in Points 1 and 4. For all of these activities, an updated report of the progress of the work, of the planning and of the expenses is given. Finally, a short ...
2001-01-01
Energy Technology Data Exchange (ETDEWEB)
The ventilation requirements for decontamination are normally determined with a static calculation method. In some cases, the pollutant emission is intermittent, for example in the car park of an office building, where all the cars enter and leave the place nearly at the same time. Generally, in such a case, the volume of the garage is large, consequently the time constant of the system has a high value. So a static approach would no longer stay accurate and a dynamic evaluation is needed. With the help of some assumptions, calculations remain rather simple and results can be plotted on nomographs or computed on a programmable handheld calculator. The amount of energy saved may appear very large in some cases. A sizing optimization will be required but also remains easy to compute. The paper presents the method of calculation for a single ventilation level and the optimization of a two-level ventilation.
1982-01-01
Tank of sodium cooled fast reactor
International Nuclear Information System (INIS)
Object: To provide a tank, which can safely and reliably accommodate high temperature sodium containing radioactive substance in case of occurrence of an accident in a sodium system and thus prevent spread of contamination. Structure: A sodium drain duct inserted into a tank from above the tank is provided at the position of its lower end with a buffer means for preventing direct flow-down of sodium to a bottom plate. A means for preventing the discharge of radioactive substance to the cover gas is provided above the lower end of the sodium drain tube so as to surround the sodium drain tube. (Kamimura, M.).
Production Data Package 267 Gallon External Fuel Tank
... It is recommended that the drawings be validated in accordance with NAVAIRINST 4333.10 and the data package, Appendix A, be used for ...
1973-08-23
High-level waste tank modifications, installation of mobilization equipment/check out
Energy Technology Data Exchange (ETDEWEB)
PUREX high-level waste (HLW) is contained at the West Valley Demonstration Project (WVDP) in an underground carbon-steel storage tank. The HLW consists of a precipitated sludge and an alkaline supernate. This report describes the system that the WVDP has developed and implemented to resuspend and wash the HLW sludge from the tank. The report discusses Sludge Mobilization and Wash System (SMWS) equipment design, installation, and testing. The storage tank required modifications to accommodate the SMWS. These modifications are discussed as well.
1992-08-31
Early Season Applications of Fluridone for Control of Curlyleaf ...
... While the large tanks served to regulate the water temper- ature, the polypropylene aquaria served as independent experimental units. ...
2010-12-01
Energy Technology Data Exchange (ETDEWEB)
This document provides structural load requirements and their basis for maintaining the structural integrity of the Hanford Single-Shell Tanks during waste feed delivery and retrieval activities. The requirements are based on a review of previous requirements and their basis documents as well as load histories with particular emphasis on the proposed lead transfer feed tanks for the privatized vitrification plant.
1999-09-22
Energy Technology Data Exchange (ETDEWEB)
This document provides data on aerosol concentrations in tank headspaces, total mass of aerosols in the tank headspace, and mass of aerosols sent to the exhauster during rotary mode core sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based upon operational data and non-destructive assay.
2001-03-23
Energy Technology Data Exchange (ETDEWEB)
This document provides data on aerosol concentrations in tank head spaces, total mass of aerosols in the tank head space and mass of aerosols sent to the exhauster during Rotary Mode Core Sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based on operation data.
2000-01-24
Energy Technology Data Exchange (ETDEWEB)
Six safety initiatives have been identified for accelerating the resolution of waste tank safety issues and closure of unreviewed safety questions. Safety Initiative 5 is to reduce safety and environmental risk from tank leaks. Item d of Safety Initiative 5 is to complete corrosion studies of single-shell tanks to determine failure mechanisms and corrosion control options to minimize further degradation by June 1994. This report has been prepared to fulfill Safety Initiative 5, Item d. The corrosion mechanisms that apply to Hanford Site single-shell tanks are stress corrosion cracking, pitting/crevice corrosion, uniform corrosion, hydrogen embrittlement, and microbiologically influenced corrosion. The corrosion data relevant to the single-shell tanks dates back three decades, when results were obtained from in-situ corrosion coupons in a few single-shell tanks. ...
1994-06-01
Harbour porpoises on Horns Reef - Effects of the Horns Reef wind farm. Annual status report 2003
Energy Technology Data Exchange (ETDEWEB)
Occurrence and distribution of harbour porpoises (Phocoena phocoena) in and around the off-shore wind farm on Horns Reef, Denmark, was investigated. This report describes data collected in 2003 as part of an ongoing monitoring program, covering a period before construction of the wind farm (baseline), the construction period in 2002 and one year following construction of the wind farm. Data from acoustic dataloggers (T-PODs) and visual surveys conducted from ships confirmed the presence of harbour porpoises inside the wind farm area during all periods investigated. Comparison with baseline data from 1999-2001 and with control areas outside the wind farm did not show a statistical significant change in sighting rates inside the wind farm area in the first year following construction relative to baseline. T-POD data showed a pronounced effect of the construction ...
2004-06-15
The effects of upwind turbine wakes on the performance of a FloWind 17-m vertical-axis wind turbine (VAWT) were investigated through a series of field experiments conducted at the FloWind wind farm on Cameron Ridge, Tehachapi, California. From the field m...
1988-01-01
Environmental Research Database
DescriptionFollowing publication of the Curry report, DEFRA have made a commitment to establish a number of pilot projects supporting a network of demonstration and development farms. These 'farms' are intended to support the process of technology transfer by giving free access to information on the practical application of new, emerging and best practice technologies. Protected Horticulture has been identified as a sub-sector requiring the establishment of one of these projects. One of the major pressures [continued...
2005-01-31
Vortex control of safety enclosures
International Nuclear Information System (INIS)
The vortex amplifier controller has no moving parts and therefore it can have extremely high reliability and avoid the maintenance problems associated with contaminated equipment. The vortex amplifier and its application to ventilation control of radioactive enclosures is described. Reverse purge vortex amplifier ventilation system control is also discussed. (U.K.).
Energy Technology Data Exchange (ETDEWEB)
Because of good thermal insulation of advanced energetic buildings and their good airtightness the air hygiene is insufficient. A normal ventilation behaviour by window opening consumes too much heating energy. A calculation method is shown taking into account a required air change number, flow rate and indoor air quality as thermal comfort in the rooms occupied by different number of persons. (GL)
2006-07-01
Super-ventilation in commercial buildings; Surventilation des locaux tertiaires
Energy Technology Data Exchange (ETDEWEB)
The preliminary results of a feasibility study of nighttime and/or daytime accelerated ventilation for reducing or even avoiding air conditioning energy consumption in commercial buildings, is presented. The first part of the study is based on computerized simulations and in-situ experimentations which are described. The second part is aimed at determining technological limitations to the various components and optimizing building environmental quality in terms of energy conservation, acoustics and air quality
1995-09-01
Current ventilation and air conditioning systems and strategies
Energy Technology Data Exchange (ETDEWEB)
The report examines common ventilation and air conditioning systems and strategies for both domestic and commercial buildings; and covers issues such as energy conservation, indoor air quality and occupant comfort. Drawing data from many countries in Europe and the United States of America, various natural, mechanical and air conditioning systems were compared using criteria such as climate, level of occupant interaction, and level of system comfort. This classification system is evaluated and seen as a valuable framework for further research. (U.K.)
1994-02-01
Energy Technology Data Exchange (ETDEWEB)
Although the Federal Facility Agreement (FFA) addresses the entire Oak Ridge Reservation, specific requirements are set forth for the liquid low-level radioactive waste (LLLW) storage tanks and their associated piping and equipment, tank systems, at ORNL. The stated objected of the FFA as it relates to these tank systems is to ensure that structural integrity, containment and detection of releases, and source control are maintained pending final remedial action at the site. The FFA requires that leaking LLLW tank systems be immediately removed from service. It also requires the LLLW tank systems that do not meet the design and performance requirements established for secondary containment and leak detection be either upgraded or replaced. The FFA establishes a procedural framework for implementing the environmental laws. For the LLLW tank systems, this framework ...
1992-03-01
Destruction of organic chemicals in Hanford HLW tanks by radiolytic and chemical aging
International Nuclear Information System (INIS)
The underground storage tanks at the Hanford Complex contain mixed wastes generated over many years from plutonium production and recovery processes. The chemical changes of the organic materials used in the extraction processes and disposed to the tanks have a direct bearing on several specific safety issues, including potential energy releases from these tanks. This paper will give details of a study that is directed towards elucidating thermal and radiological decomposition mechanisms and products of the organic contents of the tanks. The study is being conducted in two parts. The first part, an aging study, will determine kinetics and products of the degradation of a simulated waste subjected to #gamma#-radiation from an external source. Although the simulant will not contain radioactive elements, it will contain other representative inorganic compounds and the primary organic compounds thought to ...
1994-08-21
International Nuclear Information System (INIS)
The VE (ventilation) test carried out at the Mont Terri underground laboratory in Switzerland intended to evaluate in situ the behaviour of a consolidated clay formation when subjected to alternate periods of flow of wet and dry air during several months. For that, a 10-m gallery was excavated in the Opalinus Clay formation and carefully instrumented. Before and after a second ventilation phase boreholes were drilled. Samples were taken from the drill cores and were analysed from mineralogical and geochemical points of view. Also, the retention curves of these samples were determined in the laboratory following drying paths performed under free volume conditions at 20 degree centigrade, what is the content of this report. Although there are not large differences in the WRC of samples taken from different boreholes, at different distances from the gallery wall or before or after ventilation, those samples taken near the ...
2010-11-01
Natural or unnatural ventilation? Sustainable environmental management in non-residential buildings
Energy Technology Data Exchange (ETDEWEB)
Recent interest in ecologically sustainable design (ESD) has once more focussed attention upon environmental management in buildings. This paper explores the application of both air conditioning and natural ventilation in creating more sustainable non-residential buildings. In the non-residential sector the level of debate surrounding sustainable forms of environmental control and management has been disappointing. It has largely been based upon the rather simplistic argument that air conditioning is bad and natural ventilation is good and thus the only sustainable solution is naturally ventilated buildings. The paper advances the view that for both designers and managers of buildings the problem is more complex than a simple choice between air conditioning and natural ventilation. It begins with a reassessment of conventional ideas of thermal comfort and the organization of the workplace and argues ...
1995-12-31
SUSTAINABLE H/C SYSTEMS FOR CHICKEN FARMS IN SYRIA
Energy Technology Data Exchange (ETDEWEB)
Space heating/cooling systems account for approximately 30% of the global energy consumption. Such systems contribute to global warming by emitting 0.39.1011 MWh of heat and 2.9.1010 tons of CO{sub 2}. There is a general understanding that the way to reduce global warming is a more efficient use of energy and increased use of renewable energy in all fields of the society. The poultry industry in the Mid East is an important business. There are e.g. 13000 chicken farms in Syria producing 172,000 ton of meat. This industry employs directly almost 150,000 people. The total investment in chicken farming is 130 BSP. Even though, the annual mean temperature in Syria is {approx}15-18 C the winter temperatures are close to freezing for two months. Since the chickens need a temperature of 21-35 C, depending on age, approximately 168.103 tons of coal (1170 GWh) is consumed for heating these plants. The chicken farms have no cooling ...
2008-09-30
Public perceptions of wind energy developments: Case studies from New Zealand
Energy Technology Data Exchange (ETDEWEB)
Although the public generally hold positive attitudes towards wind energy, proposals for the construction of new wind farms are often met with strong resistance. In New Zealand, where the government has recently introduced ambitious policy targets for renewable energy generation, negative perceptions of wind farms are increasingly evident and have the potential to prevent the achievement of these targets. This research sets out to examine what influences social resistance to wind farms in New Zealand. Drawing from public submissions on three wind farm proposals, a framework developed by Devine-Wright [Devine-Wright, P., 2005a. Beyond NIMBYism: towards an integrated Framework for Understanding Public Perceptions of Wind Energy. Wind Energy 8, 125-139.] was used as the basis for identification of factors affecting public perceptions of wind farms. The research found firstly that there ...
2009-09-15
Public perceptions of wind energy developments. Case studies from New Zealand
Energy Technology Data Exchange (ETDEWEB)
Although the public generally hold positive attitudes towards wind energy, proposals for the construction of new wind farms are often met with strong resistance. In New Zealand, where the government has recently introduced ambitious policy targets for renewable energy generation, negative perceptions of wind farms are increasingly evident and have the potential to prevent the achievement of these targets. This research sets out to examine what influences social resistance to wind farms in New Zealand. Drawing from public submissions on three wind farm proposals, a framework developed by Devine-Wright [Devine-Wright, P., 2005a. Beyond NIMBYism: towards an integrated Framework for Understanding Public Perceptions of Wind Energy. Wind Energy 8, 125-139.] was used as the basis for identification of factors affecting public perceptions of wind farms. The research found firstly that there ...
2009-09-15
Farm & Ranch Business Management. Second Edition.
This practical guide for the agribusiness manager (the farmer, rancher, and other agribusiness people who work with agricultural commodities, supplies, and services) gives a basic understanding of modern management practices. It provides guidelines that can help them make practical business decisions. Chapter 1 is an introduction that highlights farm management efficiency, decision making, and goals and objectives. The following 11 chapters discuss recordkeeping (importance and purposes of keeping records, types of systems, record book components), financial analysis (cash flow, net worth, income statements and their ratios; whole farm and enterprise analysis; relationships of various analyses), budget analysis (introduction to types and uses of budgets, how to use and analyze a partial budget, enterprise budget and whole farm budget, production principles, cost components), cash flow analysis (projections and analysis, ...
1986-12-01
British Library Electronic Table of Contents (United Kingdom)
A web-based decision support tool, zone mapping application for precision farming (ZoneMAP, External Reference Not Shown ), has been developed to automatically determine the optimal number of management zones and delineate them using satellite imagery and field data provided by users. Application rates, such as of fertilizer, can be prescribed for each zone and downloaded in a variety of formats to ensure compatibility with GPS-enabled farming equipment. ZoneMAP is linked to Digital Northern Great Plains, a web-based application which hosts an archive of satellite imagery, as well as high resolution imagery from airborne sensors. Management zones created by ZoneMAP mapped natural variation of the soil organic matter and other nutrients relatively well and were consistent with zone maps cre...
2010-01-01
Study on regional production and economy of cobia Rachycentron canadum commercial cage culture
British Library Electronic Table of Contents (United Kingdom)
In recent years, cobia has become an emerging farmed species in Asia due to its quick growth and high economic value. This study collects biological and economic data affecting the economic performance of cobia farming in three countries, namely Taiwan, China, and Vietnam. The data are collected by questionnaire sampling and analyzed by multivariate statistical analysis in order to compare the key factors affecting the production and economy of cobia farming in these three countries. The results show that Taiwan, China, and Vietnam have significant differences in input intensities and profitability. China has the highest input intensity (3372.42?TWD/m3), as its high stocking density increases feed input. Taiwan has the highest unit input cost (103.44?TWD/kg), as the high quality of the pro...
2011-01-01
Importance of health and environment as quality traits in the buying decision of organic products
British Library Electronic Table of Contents (United Kingdom)
This paper aims to explore consumer preference for fresh vegetables labelled as organic in combination with health and environment related quality traits. The study decomposes organic farming into its main quality aspects and measures consumers' preference structure for organic, in general, and for specific organic quality traits in particular. By means of stated choice preference modelling, the following hypotheses are tested: consumers prefer health over environment related quality traits; the organic label plays a significant role in consumers' choice for organic products; organic farming is perceived as healthier and more environmentally friendly than conventional farming; purchase intention is mainly driven by health related quality traits; both health and environmental concerns influ...
2009-01-01
Farm Business Management. Volume I. Vocational Agriculture Education.
This curriculum guide provides a basic core of instruction for the first year of a three-year adult program in farm business management. It contains 12 units of instruction. Each unit consists of seven basic components: performance objectives, teacher activities, information sheets (content essential for meeting the cognitive objectives), assignment sheets (application of knowledges that are prerequisites to skill development), supplements and transparency masters, tests, and test and assignment sheet answers. Depending on the specific objectives, supplements, transparency masters, assignment sheets, and job sheets may or may not be included. The 12 units cover orientation, recordkeeping, inventory and net worth statement, depreciation, enterprise accounting and supplemental records, enterprise budgets, cash-flow planning, farm credit, partial budgeting, marketing, income tax management, and year-end closing of records. (YLB)
1983-12-01
Cats and goat whey associated with Toxoplasma gondii infection in pigs.
In organic livestock production systems, farm-management factors are thought to play an important role in the on-farm prevalence of Toxoplasma gondii. Serological results and the results of an HACCP analysis were combined to determine important risk factors for the prevalence of this protozoan parasite. Mathematical analysis demonstrated that feeding goat whey to pigs and the presence of a high number of cats were positively correlated to T. gondii seroprevalence in pigs. Not covering roughage and the farmers' assumption that pigs can come into contact with cat feces also showed a positive relationship. In order to decrease the risk of T. gondii infecting their pigs, farmers should limit the access and number of cats on their farms and refrain from feeding goat whey to their pigs. PMID:16989566
2006-01-01
Assessing farming eco-efficiency: A Data Envelopment Analysis approach
British Library Electronic Table of Contents (United Kingdom)
This paper assesses farming eco-efficiency using Data Envelopment Analysis (DEA) techniques. Eco-efficiency scores at both farm and environmental pressure-specific levels are computed for a sample of Spanish farmers operating in the rain-fed agricultural system of Campos County. The determinants of eco-efficiency are then studied using truncated regression and bootstrapping techniques. We contribute to previous literature in this field of research by including information on slacks in the assessment of the potential environmental pressure reductions in a DEA framework. Our results reveal that farmers are quite eco-inefficient, with very few differences emerging among specific environmental pressures. Moreover, eco-inefficiency is closely related to technical inefficiencies in the managemen...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
This report describes the work performed during FY 1995 by Pacific Northwest Laboratory in developing and optimizing analysis techniques for identifying organics present in Hanford waste tanks. The main focus was to provide a means for rapidly obtaining the most useful information concerning the organics present in tank waste, with minimal sample handling and with minimal waste generation. One major focus has been to optimize analytical methods for organic speciation. Select methods, such as atmospheric pressure chemical ionization mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry, were developed to increase the speciation capabilities, while minimizing sample handling. A capillary electrophoresis method was developed to improve separation capabilities while minimizing additional waste generation. In addition, considerable emphasis has been placed on developing a rapid screening tool, based on Raman and ...
1995-09-01
Realization of good indoor climate in low-energy office
Energy Technology Data Exchange (ETDEWEB)
Good indoor air quality and thermal comfort, as well as low energy consumption, were achieved in an environment friendly experimental METOP-office building in Espoo, Finland. The consumption of heating and cooling energy was minimized by installation of energy-efficient windows, good CFC-free thermal insulation of the building envelope, the individually-controlled ventilation and room temperatures, heat recovery and energy-storing structures. According to the study carried out in 1990-1993, the heating energy was 13 kWh/m{sup 3}, 60% lower than the average consumption. The index of the satisfaction of thermal comfort was over 90%. Concentrations of all the measured indoor air pollutants were low. Ventilation rates could be chosen in each office room from 10 to 40 dm{sup 3}/s. The noise level of the ventilation system was low and the lighting level was pleasant. (author)
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
In the international study of IEA Annex 27 `Demonstration and evaluation of domestic ventilation systems` a number of simple tools to gain insight into the characteristics of ventilation systems for dwellings are presented. The assessment is made with respect to e.g. indoor air quality, comfort, noise, energy, costs and reliability. In three articles the results of Annex 27 will be discussed. In the first article background information of IEA Annex 27 was given as well as applications in the Netherlands. In this second article attention is paid to the assessment models (`simplified tools`) for indoor air quality, thermal comfort and noise. 6 refs.
1999-09-01
Energy Technology Data Exchange (ETDEWEB)
Mechanical ventilation in private homes was for many years a stepchild of air conditioning engineers. A decisive impulse for change came in January 1995 with the enactment of the new Thermal Insulation Ordinance which for the first time allows house owners to exceed the usual admissible annual heating requirement by a certain amount on the condition that they equip the house with mechanical ventilation systems. (orig.) [Deutsch] Ueber lange Jahre war die mechanische Wohnungslueftung ein Stiefkind der Raumlufttechnik. Einen entscheidenden Impuls gab erst die seit Januar 1995 gueltige Waermeschutzverordnung, die erstmals zulaesst, dass ein gewisses Quantum des Jahres-Heizwaermebedarfs durch den Einbau mechanischer Wohnungslueftungen kompensiert werden kann. (orig.)
1996-10-01
CO and CO2 emissions from spontaneous heating of coal under different ventilation rates
British Library Electronic Table of Contents (United Kingdom)
Carbon monoxide (CO) and carbon dioxide (CO2) emissions during a spontaneous heating event in a coal mine are important gases to monitor for detecting the spontaneous heating at an early stage. However, in underground coal mines, the CO and CO2 concentrations and their related fire ratios may be affected by mine ventilation. In this study, CO and CO2 emissions from spontaneous heating of a U.S. coal sample were evaluated in an isothermal oven under different airflow ventilation rates ranging from 100 to 500cm^3/min. Laboratory experiments were conducted at oven temperatures of 70, 90, and 100^oC. The temperature at the center of the coal sample was continually monitored, while the CO, CO2, and oxygen (O2) concentrations of the exit gas were continually measured. The results indicate that C...
2011-01-01
Development of a solvent extraction process for cesium removal from SRS tank waste
International Nuclear Information System (INIS)
An alkaline-side solvent extraction process was developed for cesium removal from Savannah River Site (SRS) tank waste. The process was invented at Oak Ridge National Laboratory and developed and tested at Argonne National Laboratory using singlestage and multistage tests in a laboratory-scale centrifugal contactor. The dispersion number, hydraulic performance, stage efficiency, and general operability of the process flowsheet were determined. Based on these tests, further solvent development work was done. The final solvent formulation appears to be an excellent candidate for removing cesium from SRS tank waste.
2001-06-30
Corrosion and failure processes in high-level waste tanks
Energy Technology Data Exchange (ETDEWEB)
A large amount of radioactive waste has been stored safely at the Savannah River and Hanford sites over the past 46 years. The aim of this report is to review the experimental corrosion studies at Savannah River and Hanford with the intention of identifying the types and rates of corrosion encountered and indicate how these data contribute to tank failure predictions. The compositions of the High-Level Wastes, mild steels used in the construction of the waste tanks and degradation-modes particularly stress corrosion cracking and pitting are discussed. Current concerns at the Hanford Site are highlighted.
1992-11-01
Chemical compatibility study of Cooley L18KU, Herculite, and Elephant Mat with Hanford tank waste
Energy Technology Data Exchange (ETDEWEB)
An independent chemical compatibility review of various wrapping and absorbent/padding materials was conducted to evaluate resistance to chemicals and constituents present in liquid waste from the Hanford underground tanks. These materials will be used to wrap long-length contaminated equipment when such equipment is removed from the tanks and prepared for transportation and subsequent disposal or storage. The materials studied were Cooley L18KU, Herculite, and Elephant Mat. The study concludes that these materials are appropriate for use in this application.
1998-06-23
Energy Technology Data Exchange (ETDEWEB)
An anaerobic fermenter-decanter for the purification of residual water from the sugar industry, with recovery of methane, consists of a tank with inclined walls, with a central agitator on a vertical shaft. A flexible cover anchored by its periphery to the walls of the tank and totally submerged forms a collecting pocket for the fermentation gases. The water to be purified is introduced, after being heated to about 35, towards the bottom of the tank near the agitator. A metal collecting bell with submerged edges and with the shaft of the agitator passing axially through it is connected by its edges to a central opening of the cover. The purification yields may exceed 90%.
1981-10-06
Vented Bomb Tests to Characterize Propellant and ...
... Two types of combustible cartridge cases, post impregnated (PI) and beater additive (B/A) are available for the 120 mm tank gun system. ...
1990-08-01
The solubilities of significant organic compounds in HLW tank supernate solutions
International Nuclear Information System (INIS)
Large quantities of organic chemicals used in reprocessing spent nuclear-fuels at the Hanford Site have accumulated in underground high-level radioactive waste tanks. The organic content of these tanks must he known so that the potential for hazardous reactions between organic components and sodium nitrate/nitrite salts in the waste can he evaluated. The solubilities of organic compounds described in this report will help determine if they are present in the solid phases (salt cake and sludges) as well as the liquid phase (interstitial liquor/supernate) in the tanks. The solubilities of five significant sodium salts of carboxylic acids and aminocarboxylic acids [sodium oxalate, formate, citrate, nitrilotriacetate (NTA) and ethylendiaminetetraacetate (EDTA)] were measured in a simulated supernate solution at 25 degrees C, 30 degrees C, 40 degrees C, and 50 degrees C.
1994-08-21
Tanks Versus Infantry in a Smoke Environment (TISE)
... INFANTRY PARTIPI ACT 278 DATA POINTS 60 48 ... Page 21. 29 TISE HISTOGRAN-CUN CURUE INFANTRY PARTIP2 EST 895 DATA POINTS ...
1978-08-01
Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan
Energy Technology Data Exchange (ETDEWEB)
This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.
2000-04-10
Root Cause Analysis, Tank Fire Problem, M1A1 Main Battle ...
... ammunition is stored. Combustible cartridge cases could absorb moisture, swell, and not chamber properly. Additionally, moisture ...
1989-02-01
Energy Technology Data Exchange (ETDEWEB)
This technical memorandum (TM) documents the 1995 characterization of eight underground radioactive waste tanks at Oak Ridge National Laboratory (ORNL). These tanks belong to the Gunite and Associated Tanks (GAAT) operable unit, and the characterization is part of the ongoing GAAT remedial investigation/feasibility study (RI/FS) process. This TM reports both field observations and analytical results; analytical results are also available from the Oak Ridge Environmental Information System (OREIS) data base under the project name GAAT (PROJ-NAME = GAAT). This characterization effort (Phase II) was a follow-up to the {open_quotes}Phase I{close_quotes} sampling campaign reported in Results of Fall 1994 Sampling of Gunite and Associated Tanks at the Oak Ridge National Laboratory, Oak Ridge, Tennessee, ORNL/ER/Sub/87-99053/74, June 1995. The information contained here should be used in conjunction with that ...
1996-02-01
Petroleum storage tank cleaning using commercial microbial culture products
Energy Technology Data Exchange (ETDEWEB)
The removal of paraffinic bottom accumulations from refinery storage tanks represents an increasingly costly area of petroleum storage management. Microorganisms can be used to reduce paraffinic bottoms by increasing the solubility of bottom material and by increasing the wax-carrying capacity of carrier oil used in the cleaning process. The economic savings of such treatments are considerable. The process is also intrinsically safer than alternative methods, as it reduces and even eliminates the need for personnel to enter the tank during the cleaning process. Both laboratory and field sample analyses can be used to document changes in tank material during the treatment process. These changes include increases in volatile content and changes in wax distribution. Several case histories illustrating these physical and chemical changes are presented along with the economics of treatment.
1995-12-31
Management of petroleum underground storage tanks at the Hanford Site
International Nuclear Information System (INIS)
This report represents the timetables, responsible organizations, and methods required to comply with the newly promulgated Washington Administrative Code (WAC) 173-360 Underground Storage Tank (UST) Regulations which became effective December 29, 1990. This report only addresses UST systems that contain nonradioactive material. A total of 84 tanks at the Hanford Site are currently regulated under WAC 173-360. In addition, 32 regulated tanks have been removed as a result of the federally mandated program and the newly implemented state regulations. The majority of the USTs at the Hanford Site are operated by Westinghouse Hanford; however, one is operated by Kaiser Engineers Hanford (KEH) and one by Pacific Northwest Laboratory (PNL).
1991-09-08
Influence of anchor behaviour on the earthquake response of liquid storage tanks
International Nuclear Information System (INIS)
The dynamic response of thin liquid storage tanks to earthquakes is a very complicated phenomenon, because it can be highly non linear. Among others, one can meet material and geometric non linearities of the tank shell leading eventually to static or dynamic buckling non linear behavior of anchor bolts, contact non-linearities due to the uplift of the tank base and to the unilateral character of the fluid pressure on the shell and high amplitude fluid oscillations. Moreover, linear or non linear soil structure interaction affects considerably the response of the fluid structure system under consideration. In this paper we focus attention on problems related only to the base uplift and anchors plastification. We study a tank similar to the Hualien project tank, but we neglect the soil structure interaction. The studied tank is representative of medium height to ...
Handbook on Ground Forces Attrition in Modern Warfare
... 129 US Armored Division Casualty and Tank Loss Rates ..... 132 British Casualty and rank Loss Rates in Operation "Goodwood" . 134 Page 5. ...
1986-09-01
Seriously, generally fish waste does drop, but quite slowly. But a good group of snails should still do a fine job of cleaning the tank. ...
Demonstration experiments of volume measurement technique for large scale input accountancy tank
International Nuclear Information System (INIS)
Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)
2000-12-07
Watchdog Calls on USDA to Boost Transparency in Organic Governance
...qualified and who were under consideration at the time, USDA Secretary Tom Vilsack chose an animal husbandry specialist employed by one of the largest organic livestock product marketers in the country. While this appointee had grown up on a conventional farm, her immediate occupation is not that of ...
Vibrios Associated with Litopenaeus vannamei Larvae, Postlarvae, Broodstock, and Hatchery Probionts
UK PubMed Central (United Kingdom)
Several bacteriological surveys were performed from 1994 to 1996 at different Litopenaeus vannamei hatcheries (in Ecuador) and shrimp farms (in Mexico). Samples were taken from routine...Full Text Available
1999-06-01
Transmission of Salmonella mbandaka to cattle from contaminated feed.
UK PubMed Central (United Kingdom)
Salmonella mbandaka was isolated from cattle on three dairy farms. The duration of infection was less than four weeks and none of the animals became clinically ill. The animals had all consumed a diet...Full Text Available
1982-04-01
UK PubMed Central (United Kingdom)
Commercial feed rations containing sulfamethazine at the level of 110 ppm were fed for a period of 65 days to market pigs in a study simulating normal farm practices. The levels of sulfamethazine at...Full Text Available
1980-07-01
UK PubMed Central (United Kingdom)
The introduction and survival of zoonotic bacterial pathogens in poultry farming have been linked to bacterial association with free-living protozoa. To date, however, no information is available on...Full Text Available
2011-03-01
Outbreak of acute colitis on a horse farm associated with tetracycline-contaminated sweet feed.
UK PubMed Central (United Kingdom)
Exposure of a group of horses to tetracycline-contaminated feed resulted in acute colitis and subsequent death in one horse and milder diarrhea in 3 others. The most severely affected animal demonstrated...Full Text Available
1999-10-01
Organic farming in the Nordic countries--animal health and production.
Organic farming (or ecological agriculture) is of growing importance in the agricultural sector worldwide. In the Nordic countries, 1-10% of the arable land was in organic production in 1999. Organic farming can be seen as an approach to agriculture where the aim is to create integrated, humane, environmentally and economically sustainable agricultural production systems. Principles like nutrient recycling, prevention rather than treatment and the precautionary principle are included in aims and standards. Animal welfare is another hallmark of organic livestock production but despite this, several studies have indicated severe health problems e.g. in organic poultry production in Denmark. Also the quality of animal food products in relation to human health, particularly the risk of zoonotic infections, has been debated. For these reasons there is a need for improvement of production methods and animal health status. Vets play an important role ...
2001-01-01
...Agriculture Analysis of food supply chains and linkages in relation to quality and safety assurances Dept of Primary Industries, Australia Impact of food chain quality assurance requirements on farmer adoption and competitiveness UK Research Councils Review of environmental certification through farm assurance followed by industry developmental workshop Agriculture & ...
...this pathway study the following two focus modules (in addition to the six core modules) and carry out a research investigation within this theme: Agricultural Production Systems Considers the type of farming systems that have evolved globally in relation to the prevailing agro-climatic zones, the influences of economic factors ...
Mycotoxins in fungal contaminated samples of animal feed from western Canada, 1982-1994.
UK PubMed Central (United Kingdom)
Feed samples from 94 cases involving fungal contamination and suspected mycotoxicosis of farm animals in western Canada were examined during 1982-1994 to assess the incidence of mycotoxins. Samples...Full Text Available
1997-01-01
Incidence and Diversity of Potentially Highly Heat-Resistant Spores Isolated at Dairy Farms
UK PubMed Central (United Kingdom)
The presence of highly heat-resistant spores of Bacillus sporothermodurans in ultrahigh-temperature or sterilized consumer milk has emerged as an important item in the dairy industry....Full Text Available
2005-03-01
UK PubMed Central (United Kingdom)
Background and AimsSulfonylurea (SU) herbicides are used extensively in cereal–livestock farming zones as effective and cheap herbicides with useful levels of residual activity....Full Text Available
2008-05-01
UK PubMed Central (United Kingdom)
In response to reports that the contamination of food can occur during the on-farm primary phase of food production, we report data that describes a possible cost-effective intervention measure. The...Full Text Available
2004-09-01
UK PubMed Central (United Kingdom)
BackgroundTrypanosomosis is a major impediment to livestock farming in sub-Saharan Africa and limits the full potential of agricultural development in the 36 countries where it is...Full Text Available
UK PubMed Central (United Kingdom)
BackgroundA microsporidian was previously reported to infect the crustacean parasite, Lepeophtheirus salmonis (Krøyer, 1837) (Copepoda, Caligidae), on farmed...Full Text Available
UK PubMed Central (United Kingdom)
Johne disease, caused by Mycobacterium avium, subspecies paratuberculosis (MAP) is becoming increasingly widespread on dairy farms worldwide, due in part, to the absence...Full Text Available
2010-05-01
UK PubMed Central (United Kingdom)
BackgroundWhite spot syndrome (WSS) is a viral disease that affects most of the commercially important shrimps and causes serious economic losses to the shrimp farming industry worldwide....Full Text Available
UK PubMed Central (United Kingdom)
Detecting plant health conditions plays a key role in farm pest management and crop protection. In this study, measurement of hyperspectral leaf reflectance in rice crop (Oryzasativa...Full Text Available
2007-10-01
UK PubMed Central (United Kingdom)
Enzootic Glassers's disease was investigated to study the epidemiology of the disease strains on a farm where it presented a problem. Restriction endonuclease fingerprinting (REF) analysis technique...Full Text Available
1993-08-01
An initial comparative map of copy number variations in the goat (Capra hircus) genome
UK PubMed Central (United Kingdom)
BackgroundThe goat (Capra hircus) represents one of the most important farm animal species. It is reared in all continents with an estimated world population of...Full Text Available
Energy Technology Data Exchange (ETDEWEB)
On the Dutch North Sea coast, at the Westereems wind farm, the energy supplier Essent is currently implementing one of Europe's largest repowering projects. A total of 88 new wind turbines are going up at Dollart Bay. (orig.)
2009-07-01
UK PubMed Central (United Kingdom)
A public health emergency such as an influenza pandemic will lead to shortages of mechanical ventilators, critical care beds, and other potentially life saving treatments. This will raise difficult...Full Text Available
2009-01-20
Sealant tests to control radon emanation in a uranium mine. Open file report sep 79-dec 81
International Nuclear Information System (INIS)
This report describes a field-test program to determine the effectiveness of a polymeric wall sealant to reduce the escape of naturally occurring radioactive gas radon from the walls of an underground uranium mine into the ventilation air.
Remote environmental monitoring at No. 26 Colliery
Energy Technology Data Exchange (ETDEWEB)
The author describes the layout of the environmental monitoring scheme at Devco's No. 26 Colliery in Canada, which includes wall face ventilation, fan performance, and methane drainage monitoring. He gives details of the sensors, outstations, and the surface control room.
1982-03-01
Principles of room air flow; Grundlagen der Raumluftstroemung
Energy Technology Data Exchange (ETDEWEB)
The following subjects are dealt with: physics of indoor air flow, flow in individual rooms, exchange of air and pollution between individual building zones and with the outside world, thermal coupling with the building shell, thermal comfort and air quality, evaluation of the ventilation. figs., tabs., refs.
1994-12-31
In-depth industrial-hygiene survey report of the Bunge Corporation, Kansas City, Kansas
Potential exposure of workers to phosphide was examined during an in-depth industrial hygiene survey at the Bunge Corporation, in Kansas City, Kansas, where the gas was used as a grain fumigant. During the study, 14 men were employed at the facility. Tablets of aluminum phosphide were added to the grain mass for fumigation. General dilution ventilation resulted from outside air entering the work areas through ventilation louvers; there was also a local-exhaust ventilation system. Air samples revealed that, when the fumigant dispensers were being filled, workers in the area had significant exposure. At the time of the survey the relative humidity in the facility was high, permitting the reaction to phosphide to occur more readily. The levels of phosphide and respirable dust were reasonably low in the elevators, suggesting that the ventilation system was adequate. The author recommends that workers ...
1986-09-01
Impact of intraoperative lung-protective interventions in patients undergoing lung cancer surgery
UK PubMed Central (United Kingdom)
IntroductionIn lung cancer surgery, large tidal volume and elevated inspiratory pressure are known risk factors of acute lung (ALI). Mechanical ventilation with low tidal volume...Full Text Available
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
In car parks of considerable length, the removal of exhaust emissions, is carried out by air-conditioning systems mainly through transverse ventilation over short routes. The required air-conditioning ducts frequently produce a reduction in the available parking space simply due to their presence, resulting in restrictive effects on the level of acceptance by the users. In such cases, remedial action can be taken by creating ductless longitudinal ventilation. Depending on the required room air quality in the zones with the highest level of pollution, the volumetric flows for longitudinal disposal are no greater than those for conventional transverse ventilation. In conjunction with architecturally clear and positive lighting designs, clearly laid out car parks with a friendly atmosphere can be created which the user will be pleased to accept. (orig./BWI)
1994-03-01
Energy Technology Data Exchange (ETDEWEB)
;Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.
1993-01-01
Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.
1993-01-01
Diesel equipment: is it safe to use underground
Energy Technology Data Exchange (ETDEWEB)
Research indicates that diesel equipment can be used safely in undergound coal mines provided that certain conditions prevail. These conditions are: the machines and engines are approved for underground use, an adequate maintenance and training program is in effect, an adequate monitoring system with proper instrumentation is used, and adequate ventilation is maintained.
1984-04-01
A 40 GByte/s read-out system for GEM
Energy Technology Data Exchange (ETDEWEB)
The preliminary design of the read-out system for the GEM (Gammas, Electrons, Muons) detector at the Superconducting Super Collider is presented. The system reads all digitized data from the detector data sources at a Level 1 trigger rate of up to 100 kHz. A total read-out bandwidth of 40 GBytes/s is available. Data are stored in buffers that are accessible for further event filtering by an on-line, processor farm. Data are transported to the farm only as they are needed by the higher-level trigger algorithms, leading to a reduced bandwidth requirement in the Data Acquisition System.
1994-04-01
Ventilation concept, indoor air quality and measurement results in the ``Passivhaus Kranichstein``
Energy Technology Data Exchange (ETDEWEB)
The ``Passivhaus Darmstadt-Kranichstein`` is a 4 unit terrace house with an extremely low total annual energy consumption of less than 32 kWh/m{sup 2} of living area, thereof about 12 kWh are needed for room heating. The determining factors for the low consumption are the superinsulation, airtightness of the thermal envelope in combination with a highly efficient VAV ventilation system, and an improved window construction. The results of a detailed monitoring program allow decisive statements concerning reduction of energy consumption, relief of environment, indoor air quality, and thermal comfort. (author)
1994-12-31
Unified requirements for monitoring of ventilation of drifts in coal and shale mines
Energy Technology Data Exchange (ETDEWEB)
Ventilation of blind drifts in the Karaganda Basin because of the high release of methane is a very important task. As indicated by measurements in 116 blind drifts, on the average the magnitude of air velocity in the pipelines VPM is in limits of 15-25 m/sec. The DPV-1 sensor encompasses almost the entire range of velocities of air motion. Operation of the DPV-1 sensors at mines of the production association ''Karaganda-ugol''' confirmed their high reliability and convenience for operation.
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
In the 1988 February issue of this magazine the units olf and decipol were introduced. Olf is a measure for the pollution load and decipol for the indoor air quality. This article discusses a new ventilation theory which is quantified by the new indoor air quality thermal comfort balance based on the units olf and decipol. This balance requires more ventilation air than for the present regulations. It takes into account all pollution sources. 2 figs., 9 refs., 3 tabs.
1990-05-01
Displacement ventilation in industry - a design principle for improved air quality
Energy Technology Data Exchange (ETDEWEB)
There is very little quantitative documentation of actual improvements resulting from the installation of new general ventilation systems in industrial settings. Therefore the performance of the common mixing design principle was compared to the displacement design principle by means of an intervention study in a workshop (V = 12,000 m[sup 3]), where thermoplastics were moulded. An experimental signal-response tracer gas technique was used. In terms of supplying fresh air to the zone of occupancy the displacement system was better than the mixing system by a factor of 2. In terms of the exposure level to a simulated contaminant (tracer gas) the displacement system was better by a factor 1.5-18. (author)
1992-10-01
Dampers, fluidics and the failsafe fallacy [fire protection
International Nuclear Information System (INIS)
The fire protection practices adopted at nuclear power stations generally follow the well established principles used throughout industry. Unfortunately, there is one particular area - the interaction with heating, ventilation and air conditioning (HVAC) services - where nuclear power stations pose a seemingly insoluble conflict: that between the need to contain and the need to ventilate. Now, however, solid state fire dampers using power fluidics may promise a solution. One of the key characteristics of a fluidic device is that it is 'solid state', i.e. it has no moving parts. Because of this, its inherent reliability is orders of magnitude greater than a mechanical device. (U.K.).
A conceptual model for laboratory ventilation greenhouse gas planning
British Library Electronic Table of Contents (United Kingdom)
There is increasing pressure to operate laboratory facilities in environmentally and financially sustainable ways. A key factor in achieving this goal is careful consideration of how energy is used by the buildings' ventilation system, both for conditioning air supplied to the laboratories and the energy used moving air through the building. Traditionally, laboratory energy use is treated as an engineering concern within the scope of the building's overall design and operation. However, this approach limits the involvement of key stakeholders in many important decisions and can lead to unexpected safety concerns for the laboratory's users. We believe that a broad view of the parties affected by a laboratory building's operations is necessary to avoid having the various stakeholders working...
2011-01-01
Forecasting for utility-scale wind farms. The power model challenge
Energy Technology Data Exchange (ETDEWEB)
As the penetration of wind energy continues to increase around the world, with a trend towards large utility-scale wind farms (greater than 100 MW), effective wind energy forecasting will become increasingly important. Previous work by GH has estimated the trading benefit of high quality short-term forecasting to be EUR 7/MWh. Depending on market conditions, for a 100 MW wind farm with a capacity factor of 30%, this equates to an estimated annual trading benefit of up to EUR 1.8m. To date, a number of studies have focused on the mathematical modelling techniques for forecasting the production from wind farms, looking predominantly at the task of predicting the meteorological conditions at the site. This paper focuses on the final stage of the forecasting process, conversion from a meteorological forecast to a power production forecast. This challenge is particularly significant for utility-scale wind ...
2008-07-01
Analysis of thermal comfort and indoor air quality in a mechanically ventilated theatre
Energy Technology Data Exchange (ETDEWEB)
Theatres are the most complex of all auditorium structures environmentally. They usually have high heat loads, which are of a transient nature as audiences come and go, and from lighting which changes from scene to scene, and they generally have full or nearly full occupancy. Theatres also need to perform well acoustically, both for the spoken word and for music, and as sound amplification is less used than in other auditoria, background noise control is critically important. All these factors place constraints on the ventilation design, and if this is poor, it can lead to the deterioration of indoor air quality and thermal comfort. To analyse the level of indoor air quality and thermal comfort in a typical medium-sized mechanically ventilated theatre, and to identify where improvements could typically be made, a comprehensive post-occupancy evaluation study was carried out on a theatre in Belgrade. The evaluation, based on the results of ...
2008-07-01
W-12 valve pit decontamination demonstration
Energy Technology Data Exchange (ETDEWEB)
Waste tank W-12 is a tank in the ORNL Low-Level Liquid Waste (LLLW) system that collected waste from Building 3525. Because of a leaking flange in the discharge line from W-12 to the evaporator service tank (W-22) and continual inleakage into the tank from an unknown source, W-12 was removed from service to comply with the Federal Facilities Agreement requirement. The initial response was to decontaminate the valve pit between tank W-12 and the evaporator service tank (W-22) to determine if personnel could enter the pit to attempt repair of the leaking flange. Preventing the spread of radioactive contamination from the pit to the environment and to other waste systems was of concern during the decontamination. The drain in the pit goes to the process waste system; therefore, if high-level liquid waste were generated during decontamination activities, it would ...
1995-12-01
Energy Technology Data Exchange (ETDEWEB)
The Federal Aviation Administration (FAA) identified 17 accidents that may have resulted from fuel tank explosions on commercial aircraft from 1959 to 2001. Seven events involved JP 4 or JP 4/Jet A mixtures that are no longer used for commercial aircraft fuel. The remaining 10 events involved Jet A or Jet A1 fuels that are in current use by the commercial aircraft industry. Four fuel tank explosions occurred in center wing tanks (CWTs) where on-board appliances can potentially transfer heat to the tank. These tanks are designated as ''Heated Center Wing Tanks'' (HCWT). Since 1996, the FAA has significantly increased the rate at which it has mandated airworthiness directives (ADs) directed at elimination of ignition sources. This effort includes the adoption, in 2001, of Special Federal Aviation Regulation 88 of 14 CFR part 21 ...
2007-02-07
Implementation guide for Hanford Tanks Initiative C-106 heel retrieval contract management HNF-2511
Energy Technology Data Exchange (ETDEWEB)
This report is an Implementation Guide for Hanford Tanks Initiative C-106 heel retrieval contract management HNF-2511 to provide a set of uniform instructions for managing the two contractors selected. The primary objective is to produce the necessary deliverables and services for the HTI project within schedule and budget.
1998-04-17
Development of an experimental installation for short-lived isotopes production in INR linac
International Nuclear Information System (INIS)
A possibility of short-lived isotopes production in inter-tank section between the first and the second drift tube tanks (20.45 MeV) in INR linac is considered. At the initial stage the main efforts are concentrated on production of fluorine-18 used for positron emission tomography. The results of beam forming calculations, target heating calculations, equipment activation calculations as well as installation configuration and design are presented.
2010-01-01
DOUBLE-SHELL TANK (DST) HYDROXIDE DEPLETION MODEL FOR CARBON DIOXIDE ABSORPTION
International Nuclear Information System (INIS)
This document generates a supernatant hydroxide ion depletion model based on mechanistic principles. The carbon dioxide absorption mechanistic model is developed in this report. The report also benchmarks the model against historical tank supernatant hydroxide data and vapor space carbon dioxide data. A comparison of the newly generated mechanistic model with previously applied empirical hydroxide depletion equations is also performed.
2009-04-30
Energy Technology Data Exchange (ETDEWEB)
Plans for the disposal of radioactive liquid and solid wastes presently stored in double-shell tanks at the Hanford Site call for retrieval and processing of the waste to create forms suitable for permanent disposal. Waste will be retrieved from a tank using a submerged slurry pump in conjunction with one or more rotating slurry jet mixer pumps. Pacific Northwest Laboratory (PNL) has conducted tests using simulated waste slurries to assess the effects of a impinging slurry jet on the corrosion rate of the tank wall and floor, an action that could potentially compromise the tank`s structural integrity. Corrosion processes were investigated on a laboratory scale with a simulated neutralized cladding removal waste (NCRW) slurry and in a subsequent test with simulated neutralized current acid waste (NCAW) slurry. The test slurries simulated the actual NCRW and NCAW both chemically and physically. The tests ...
1992-01-01
International Nuclear Information System (INIS)
Purpose: To permit accurate detection of sodium leakage by distinguishing between variations in the overflow tank level due to changes in sodium temperature accompanying changes in the power level or operating state of a liquid metal sodium cooled fast breeder, and a reduction in power level due to duct leakage. Constitution: The volume of sodium in the primary cooling system is roughly estimated from the temperatures of hot and cold legs, and the duct leak preset level with respect to the sodium liquid level within an overflow tank when the plant is normal is varied according to the state of the plant. More particularly, the volume of sodium within the overflow tank is calculated on the basis of a signal representing the liquid level detected by a liquid level gauge in the overflow tank and a signal representing the temperature detected by hot leg and cold leg thermometers, thereby obtaining the preset ...
Potential for erosion corrosion of SRS high level waste tanks
Energy Technology Data Exchange (ETDEWEB)
SRS high-level radioactive waste tanks will not experience erosion corrosion to any significant degree during slurry pump operations. Erosion corrosion in carbon steel structures at reported pump discharge velocities is dominated by electrochemical (corrosion) processes. Interruption of those processes, as by the addition of corrosion inhibitors, sharply reduces the rate of metal loss from erosion corrosion. The well-inhibited SRS waste tanks have a near-zero general corrosion rate, and therefore will be essentially immune to erosion corrosion. The experimental data on carbon steel erosion corrosion most relevant to SRS operations was obtained at the Hanford Site on simulated Purex waste. A metal loss rate of 2.4 mils per year was measured at a temperature of 102 C and a slurry velocity comparable to calculated SRS slurry velocities on ground specimens of the same carbon steel used in SRS waste tanks. Based on these data ...
1994-01-01
Energy Technology Data Exchange (ETDEWEB)
The improvement in the functions of the viscous flow calculation method VEGA-SHIP around a ship and the expansion of application range were described as the numerical flow simulation in ship and ocean engineering and at the same time application examples to the ocean engineering by the general-purpose flow simulation code FLOW-3D handling the non-steady flow with a free surface were introduced as the numerical simulation regarding such products as a water gate and a dam. In the VEGA-SHIP, water surface was handled as a fixed wall so that wave could not be calculated. Therefore, an algorithm for calculating wave on the water surface was added to the VEGA-SHIP and a calculation method simultaneously considering the creation of wave around the ship and viscosity was developed. The FLOW-3D was used to calculate the phenomenon where inside liquid moved greatly due to the oscillation of a tank and hit against and damaged the tank ceiling in the ...
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
Laboratory experiments were conducted to simulate the transfer of acidic THOREX waste from Tank 8D-4 into the alkaline PUREX waste in Tank 8D-2 at West Valley. The purpose of the experiments was to explore means of minimizing the production of nitric oxide (NO) gas during mixing of the two wastes and to assess the potential for the gas to further react in the vapor space possibly leading to enhanced corrosion of the tank walls. Forty one THOREX/PUREX mixing tests were conducted to explore the effects of stirring rate, pH, THOREX addition rate, THOREX or PUREX dilution, and temperature. The two most important criteria for minimizing NO production were to maintain some degree of agitation and the keep the pH in the PUREX high, preferably >12. Steel corrosion tests were performed in the presence of low partial pressures of NO{sub 2} and liquid water or water vapor. The NO{sub 2} (from oxidation of NO in the vapor space) ...
1995-05-01
Elephant's foot phenomenon in liquid storage tanks
Energy Technology Data Exchange (ETDEWEB)
This paper presents a method for analyzing the seismic response of a flat bottomed cylindrical liquid storage tank to vertical earthquake excitation. Here, vertical earthquake acceleration is considered to correspond to an increase in the density of a stored liquid. Taking into account the vertical and horizontal earthquake loads, hydrostatic pressure, and considering restrictive moment and shear forces at shell-bottom welded joint, the author has calculated circumferential and longitudinal stresses. These are combined to more accurately approximate the stresses at the base shell course. The calculated result closely conforms to the actual damage, termed ''elephant's foot,'' observed in the fuel storage tanks damaged in the Tangshan earthquake. This result shows that the ''elephant's foot'' phenomenon is not caused by buckling of the ...
1983-01-01
Depleted uranium human health risk assessment, Jefferson Proving Ground, Indiana
Energy Technology Data Exchange (ETDEWEB)
The risk to human health from fragments of depleted uranium (DU) at Jefferson Proving Ground (JPG) was estimated using two types of ecosystem pathway models. A steady-state, model of the JPG area was developed to examine the effects of DU in soils, water, and vegetation on deer that were hunted and consumed by humans. The RESRAD code was also used to estimate the effects of farming the impact area and consuming the products derived from the farm. The steady-state model showed that minimal doses to humans are expected from consumption of deer that inhabit the impact area. Median values for doses to humans range from about 1 mrem ({plus_minus}2.4) to 0.04 mrem ({plus_minus}0.13) and translate to less than 1 {times} 10{sup {minus}6} detriments (excess cancers) in the population. Monte Carlo simulation of the steady-state model was used to derive the probability distributions from which the median values were drawn. Sensitivity analyses of the ...
1994-04-29
Energy Technology Data Exchange (ETDEWEB)
Plans for the disposal of radioactive liquid and solid wastes presently stored in double-shell tanks at the Hanford Site call for retrieval and processing of the waste to create forms suitable for permanent disposal. Waste will be retrieved from a tank using a submerged slurry pump in conjunction with one or more rotating slurry jet mixer pumps. Pacific Northwest Laboratory (PNL) has conducted tests using simulated waste slurries to assess the effects of a impinging slurry jet on the corrosion rate of the tank wall and floor, an action that could potentially compromise the tank's structural integrity. Corrosion processes were investigated on a laboratory scale with a simulated neutralized cladding removal waste (NCRW) slurry and in a subsequent test with simulated neutralized current acid waste (NCAW) slurry. The test slurries simulated the actual NCRW and NCAW both chemically and physically. ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
Energy conservative building design has triggered greater interests in developing flexible and sophisticated air conditioning systems capable of achieving enhanced energy-savings potential without sacrificing the desired thermal comfort and indoor air quality (IAQ). This research work greatly aimed at achieving enhanced energy conservation, good thermal comfort and better IAQ for space conditioning with the application of combined variable refrigerant volume (VRV) and variable air volume (VAV) air conditioning (A/C) systems. Experimental investigation on the proposed combined air conditioning system with the application of intelligent fuzzy logic controller was performed for summer and winter climatic conditions to substantiate the energy-savings capability. The proposed system experimentally analyzed under fixed ventilation, demand controlled ventilation (DCV) and combined DCV and economizer cycle (EC) ventilation ...
2010-04-15
Status and progress in sludge washing: A pivotal pretreatment method
Energy Technology Data Exchange (ETDEWEB)
Separation of the bulk soluble chemical salts from the insoluble metal hydroxides and radionuclides is central to the strategy of disposing Hanford tank waste. Sludge washing and caustic leaching have been selected as the primary methods for processing the 230 million L (61,000,000 gal) of Hanford tank waste. These processes are very similar to those selected for processing waste at the West Valley Site in New York and the Savannah River Site in South Carolina. The purpose of sludge washing is to dissolve and remove the soluble salts in the waste. Leaching of the insoluble solids with caustic will be used to dissolve aluminum hydroxide and chromium hydroxide, and convert insoluble bismuth phosphate to soluble phosphate. The waste will be separated into a high-level solids fraction and a liquid fraction that can be disposed of as low-level waste after cesium removal. The washing and leaching operations involve batchwise mixing, settling, and ...
1995-01-01
Some aspects of concentrated sulphuric acid storage tank corrosion
Energy Technology Data Exchange (ETDEWEB)
Carbon steel is frequently used to construct concentrated sulphuric acid storage tanks. This paper discussed the corrosion performance of carbon steel tanks and outlined the underlying mechanisms responsible for major corrosion modes. Analyses of hydrogen grooving and dilute acid corrosion failure mechanisms were presented. Recent corrosion-induced leak failures were also discussed. The use of anodic protection and organic coatings as a corrosion control measure was also evaluated. The results of laboratory studies that were conducted to understand corrosion-induced failures showed that carbon steel electrodes exhibited transpassive corrosion at relatively high anodic potentials, while stainless steel electrodes exhibited transpassive corrosion at anodic potentials less than 1 V. It was concluded that corrosion-induced leaks can be prevented by using anodic protection and baked phenolic coating technologies. 23 refs., 9 figs.
2009-07-01
International Nuclear Information System (INIS)
Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).
Energy Technology Data Exchange (ETDEWEB)
The characteristics of diesel fuel jet atomization in carburetors depend on dynamic viscosity (v) density (d) and surface tension (st) of fuel, grouped in the combined functions v/d; st/v and st/d. Values of these combined functions for binary mixtures of a farm diesel fuel with a crude vegetable oil (sunflower, soybean, cotton and foot-cake olive oils) as well as with a used frying olive oil, are calculated. Three different diesel fuels have been studied. Combined function values of these mixtures are influenced by the characteristics of their diesel fuel. Mixtures containing less than 24% of any studied crude oils show kinematic viscosity values at 40 degrees C not exceeding 5.8 squared millimeters/s. This value is the higher limit for typical United States farm diesel fuels, according to specifications of the Cummins Engine Company. Mixture with 21% of the used frying olive oil shows at 40 degrees C this kinematic viscosity.
1985-09-01
Energy Technology Data Exchange (ETDEWEB)
The first offshore wind farm in Sweden; Bockstigen, consists of five 500 kW stall controlled wind turbines on mono pile foundations. The main objectives of the technical evaluation are to verify the original design assumptions made for a load carrying mono pile and bedrock, investigate offshore power production versus onshore ditto as well as to determine park effects and analyse meteorological multi-mast statistics which serve as reference data to a newly developed computer code for offshore wind energy potential mapping. The 'main' measurement system has continuously been acquiring data at 1 and 20 Hz/channel since the summer of 1998. A 40 m meteorological mast was built within the wind farm in the summer of 1999 in order to acquire relatively undisturbed wind speed data from 'free' sectors as well as to enable wake measurements. The mono pile and tower of one of the turbines are equipped with strain gauges ...
2001-12-01
Energy Technology Data Exchange (ETDEWEB)
Previous studies have found that classrooms are often inadequately ventilated, with the resultant increased risk of negative impacts on the pupils. This paper describes a series of field measurements that investigated the indoor air quality, thermal comfort and acoustic performance of nine recently built secondary schools in England. The most significant conclusion is that the complex interaction between ventilation, thermal comfort and acoustics presents considerable challenges for designers. The study showed that while the acoustic standards are demanding it was possible to achieve natural ventilation designs that met the criteria for indoor ambient noise levels when external noise levels were not excessive. Most classrooms in the sample met the requirement of limiting the daily average CO{sub 2} concentration to below 1500 ppm but just a few met the need to readily provide 8 l/s per person of fresh air under the easy ...
2009-07-15
Energy Technology Data Exchange (ETDEWEB)
Sensors installed at a telephone office building in Neenah, WI, continuously monitor 24 parameters related to the operation of the building's heating, ventilating, and air conditioning (HVAC) system. This data is stored in a dedicated minicomputer and can be retrieved, in various formats, for subsequent analyses. For more than a year, we have measured indoor and outdoor concentrations of both fine and coarse airborne particles, their chemical constituents, and volatile organic compounds at this same location. Using this data, we have examined the composition of the indoor air as it correlates to the composition of the outdoor air and the various HVAC operating parameters. The steady-state indoor concentrations of the particles, particulate constituents, and organic vapors can be explained in the context of a mass balance model. This model can also be used to calculate the rate at which selected chemicals are generated within the building, as well as to ...
1989-01-01
Test-bed for compact ventilation units; Pruefstand fuer Kompaktlueftungsgeraete fuer Komfortlueftung
Energy Technology Data Exchange (ETDEWEB)
This comprehensive, illustrated report for the Swiss Federal Office of Energy (SFOE) by the University of Applied Sciences in Lucerne, Switzerland takes a look at the testing facility at the university that is used to test compact ventilation systems. These feature heat-recovery and return-air heat-pumps and are used in housing built to low energy-consumption standards such as the Swiss 'Minergie' and 'Minergie-P' standards. The primary goal is a technically comprehensive testing programme for compact ventilation units with heat recovery and heat pumps, which can nevertheless be carried out at reasonable cost. In addition to thermal and flow measurements, acoustic measurements are also carried out. The authors quote that the overall assessment provided can also include service and maintenance, materials used and possible problems with thermal bridges. The test installation is described and the testing ...
2005-12-15
Energy Technology Data Exchange (ETDEWEB)
Ventilation, cooling and illumination of modern high-rise office buildings with high-quality thermal insulation (average k-value 1.0 W/m12K) and high loads from office machinery (up to 20 W/m12 and beyond) are problematic even for modern facility management systems, with consequences for the building shell, heating system, and window ventilation. [Deutsch] Die Lueftung, Kuehlung und Beleuchtung moderner Buerohochbauten mit extremer Waermedaemmung (mittlerer K-Wert 1,0 W/m{sup 2}K) und hohen Bueromaschinenlasten (bis zu 20 W/m{sup 2} und mehr) verursachen auch heute noch erhebliche Probleme, obwohl die technische Gebaeudeausruestung weiterentwickelt wurde. Dies zeigt sich vor allem bei der Fassadenausbildung der Heizung und Fensterlueftung. (orig.)
1999-11-01
The role of RFID in agriculture: Applications, limitations and challenges
British Library Electronic Table of Contents (United Kingdom)
The recent advances in RFID offer vast opportunities for research, development and innovation in agriculture. The aim of this paper is to give readers a comprehensive view of current applications and new possibilities, but also explain the limitations and challenges of this technology. RFID has been used for years in animal identification and tracking, being a common practice in many farms. Also it has been used in the food chain for traceability control. The implementation of sensors in tags, make possible to monitor the cold chain of perishable food products and the development of new applications in fields like environmental monitoring, irrigation, specialty crops and farm machinery. However, it is not all advantages. There are also challenges and limitations that should be faced in the...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The economic development of eastern Europe was associated during the last 15 years with the following average annual increases in energy consumption: Approximately 1% in the sectors industry, building and transport, almost 7% in the farming sector, approximately 3% in households, and nearly 4% in the municipal sector. This trend will not continue. As the economic system shifts from centrally planned to free economy and as the previously secluded economy is forced to face world market conditions as well as changed pars of exchange and conditions of payment, it not only experiences a transitory, sharp dip of economic growth in general but, in particular, drastic structural changes. - While there is to be expected, on the whole a slump in national economic growth, in tradiational branches of industry (e.g., metallurgy, the chemicals and textile industry) as well as in farming, such sectors as the service industry and small trade are expanding. ...
1991-10-01
Energy Technology Data Exchange (ETDEWEB)
This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that involves the building of a joint biogas plant serving 60 farmers and industrial companies with an annual processing capacity of 45,000 tons. The plant is to produce biogas to be fed into the gas mains and will not only reduce nutrient loading in a region with an extensive livestock industry but also reduce carbon dioxide emissions by using the gas as a motor fuel. The importance of the project with respect to both the environment and energy policy-making is discussed and the costs involved are examined. Details are presented on the technology used and on the material flows involved. Figures are quoted on energy production. The various biogenic substrates used, such as food wastes, waste oils, cereal wastes and used mushroom substrates, are discussed, as is the use of the solid and liquid outputs of the digester in farming activities.
2005-07-01
British Library Electronic Table of Contents (United Kingdom)
Purpose The mangroves of New Caledonia, in the south Pacific, act as a buffer between a lagoon of more than 20,000?km2 and the island, which is characterized by ultramafic rocks and lateritic soils that are exploited for their richness in heavy metals. We will provide a better understanding of the redox conditions, and of heavy metal distributions in mangroves receiving shrimp farm effluents. Materials and methods Samples were collected from four areas defined in terms of vegetation composition: a salt flat, an Avicennia marina forest, in which effluents are released; a Rhizophora stylosa forest, and a dead Rhizophora forest. They were collected during times of maximum effluent release. Some measurements on pore water were also done during a period without effluent. Cores (70?cm deep) were...
2011-01-01
Real-time configuration changes of the ATLAS High Level Trigger
The ATLAS High Level Trigger (HLT) is a distributed real-time software system that performs the final online selection of events produced during proton-proton collisions at the Large Hadron Collider (LHC). It is designed as a two-stage trigger and event filter running on a farm of commodity PC hardware. Currently the system consists of about 850 processing nodes and will be extended incrementally following the expected increase in luminosity of the LHC to about 2000 nodes. The event selection within the HLT applications is carried out by specialized reconstruction algorithms. The selection can be controlled via properties that are stored in a central database and are retrieved at the startup of the HLT processes, which then usually run continuously for many hours. To be able to respond to changes in the LHC beam conditions, it is essential that the algorithms can be re-configured without disrupting data taking while ensuring a consistent and reproducible ...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
The Pacific white shrimp, Litopenaeus vannamei, is the most important shrimp species in volume in world aquaculture. However, in recent decades, outbreaks of diseases, especially viral diseases, have led to significant economic losses, threatening the sustainability of shrimp farming worldwide. In 2004, Brazilian shrimp farming was seriously affected by a new disease caused by the Infectious myonecrosis virus (IMNV). Thus, disease control based on rapid and sensitive pathogen detection methods has become a priority. In this study, a specific quantitation method for IMNV was developed using real-time PCR with SYBR Green chemistry and viral load of the principal target tissues of chronically infected animals was quantified. The quantitative analysis revealed that mean viral load ranged from ...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Development of inhibitors and vaccines that mitigate rumen-derived methane by targeting methanogens relies on knowledge of the methanogens present. We investigated the composition of archaeal communities in the rumens of farmed sheep (Ovis aries), cattle (Bos taurus) and red deer (Cervus elaphus) using denaturing gradient gel electrophoresis (DGGE) to generate fingerprints of archaeal 16S rRNA genes. The total archaeal communities were relatively constant across species and diets, and were less variable and less diverse than bacterial communities. There were diet- and ruminant-species-based differences in archaeal community structure, but the same dominant archaea were present in all rumens. These were members of three coherent clades: species related to Methanobrevibacter ruminan...
2011-01-01
Lead, cadmium, chromium, cobalt, and copper in chicken feathers from Tuskegee, Alabama
Energy Technology Data Exchange (ETDEWEB)
The feather has been widely used as a indicator tissue of metal exposure in birds. The feathers were collected from Tuskegee University poultry farm (TUPF) and Harrison Poultry farm (HPF) chicken and analyzed by Inductively Coupled Plasma Atomic Emission Spectroscopy for lead, cadmium, cobalt, chromium, and copper contaminations. The mean levels of lead, cadmium, cobalt, chromium, and copper in TUPF chicken were 3.67, 0.13, 12.23, 0.22, and 7.71 ppm, respectively, and in HPF chicken were 5.32, 0.096, 11.03, 0.15, and 8.06 ppm, respectively. The mean levels of these metals did not show any significant difference between TUPF and HPF chicken.
1994-12-31
Exploration of the hypothalamic?pituitary?adrenal function as a tool to evaluate animal welfare
British Library Electronic Table of Contents (United Kingdom)
Measuring HPA axis activity is the standard approach to the study of stress and welfare in farm animals. Although the reference technique is the use of blood plasma to measure glucocorticoid hormones (cortisol or corticosterone), several alternative methods such as the measurement of corticosteroids in saliva, urine or faeces have been developed to overcome the stress induced by blood sampling itself. In chronic stress situations, as is frequently the case in studies about farm animal welfare, hormonal secretions are usually unchanged but dynamic testing allows the demonstration of functional changes at several levels of the system, including the sensitization of the adrenal cortex to ACTH and the resistance of the axis to feedback inhibition by corticosteroids (dexamethasone suppression t...
2007-01-01
Assessing soil quality under intensive cultivation and tree orchards in Southern Italy
British Library Electronic Table of Contents (United Kingdom)
Concerns about groundwater contamination as well as pesticide residues in food and soil have fuelled vigorous debates about the sustainability of chemical-intensive agriculture. Search has been prompted for agronomic strategies with lower environmental hazards. In this multidisciplinary study we compared the characteristics of soils from 20 agricultural farms selected in five geographical areas of Southern Italy with different soil types. In each farm, fields with management regime classified as high-input (HIMR, intensive cultivation under plastic tunnels) or low-input (LIMR, tree orchards) were selected. Soil samples were analyzed for 31 parameters including physical and chemical properties (bulk density, water holding capacity, texture, pH, limestone, electrical conductivity, organic C ...
2011-01-01
Assessing farm-level agricultural sustainability over a 60-year period in rural eastern India
British Library Electronic Table of Contents (United Kingdom)
Agricultural sustainability is a vital parameter to be ascertained locally and globally if food security is to be achieved and maintained. Agricultural sustainability is the combined product of social, economic and ecological sustainability. It is also a function of temporal and spatial variations, a fact which indicates that area-specific sustainability indices need to be designed. We present here an Agricultural Sustainability Index (ASI) for rural eastern India and use it to calculate the ASI for 150 farms for three decades over a 60-year period, viz., 1950?1960, 1980?1990 and 2000?2010 for a representative Indian village of Gangapur (25?83?N, 85?65?E). The ASI was calculated using 30 variables, 10 each of social, economic and ecological sustainability. An extensive questionnaire-based ...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
We show that the HACCP system is not fully applicable at the primary production level, and that food safety is obtained through the careful implementation of good hygiene practice (GHP) at the farm. Guides to GHP intended at primary productions cover one activity, such as cattle rearing or corn production. Yet most farms have more than one activity. Hazards from one activity can be transferred to another activity, and in general this is not considered in one-activity guides. There is a need therefore for farmers to be able to detect and control such transfers. We suggest a horizontal complement to the Guides to GHP that would consider only the application of the Step 6 and Principle 1 of the HACCP system amended as follows: ''List all potential hazards transferred from one activity to anot...
2011-01-01
International Nuclear Information System (INIS)
The RESF is utilized for storage of spent fuel under emergency conditions as well as for testing of FM heads. It receives cooling supply from the PHT Pressurizing pumps and after removal of decay heat from the spent fuel it goes to the D2O Storage Tank. The geometry of the RESF system is such that it can not sustain the thermosyphon loop during SBO, due to high frictional forces. To achieve the sustained thermosyphon, modifications in the design were suggested viz., removal of the steam trap and the relief valve above it and replacement by a solenoid valve (SV-16). In the event of SBO, SV-16 will open on 'RESF channel temperature high' signal and connect to FT D2O tank. The tank, being at atmospheric pressure and at lower elevation, will provide higher cooling flow rate through the RESF channel. D2O is periodically removed from the FT D2O tank by operating a Class-II pump intermittently. The analysis ...
2006-11-13
The electric fuel zinc-air battery option
Energy Technology Data Exchange (ETDEWEB)
With specific energy of more than 200 Wh/kg, the Electric Fuel zinc-air battery delivers as much as eight times the energy of lead-acid traction battery, more than twice the energy of the nearest advanced-battery competitor, and as much energy as a tank of gasoline. (author)
1995-12-31
UK PubMed Central (United Kingdom)
Sewage waste disposal facilities in the Florida Keys include septic tanks and individual package plants in place of municipal collection facilities in most locations. In Key Largo, both facilities discharge...Full Text Available
1995-06-01
Measurement of mud level interfaces: A tool for optimization of red mud washing at C.V.G. Bauxilum
Energy Technology Data Exchange (ETDEWEB)
For the expansion to 2.0 MTPY of the CVG Bauxilum alumina plant, the area of clarification and red mud washing was rearranged from four 2-thickener-5-washer trains to two 1-thickener-7-washer trains. As a result of this modification, the specific mud handling capacity of the existing tanks should be increased by almost 3-times. The time allowed for control actions was then significantly reduced, leading to the need of an on-line level detection system, in order to achieve a better and faster control of the operation. With this scope, it was developed and installed a new continuous mud level detector that gives the measurement of both mud and turbid zone levels in the tanks. The development of the new instrument started with an existing instrument for density measurements which was completely re-engineered in order to obtain the maximum readability in the densities founded along the full range of the tank height. Actually 28 ...
1996-10-01
Investigation of Residue and Coating Stoichiometry on 120-mm Combustible Cartridge Cases.
An investigation was conducted to determine the cause of coating residue found in the test gun chambers during qualification firing of 120-mm combustible cartridge case (CCC) ammunition for the MlAl/A2 main battle tank. The CCC is coated with a clear epox...
2000-01-01
Foundation of offshore structures
Energy Technology Data Exchange (ETDEWEB)
This bibliography deals with the foundation of offshore structures like drilling or working platforms (oil and gas exploitation) or offshore tanks. Different kinds of foundations, e.g. pile foundations or shallow foundations, are described. Aspects of soil-structure interaction, engineering geology and soil mechanics are also discussed. (orig.).
1989-08-01
FIELD CORROSION TESTS IN REDOX AND PUREX UNDERGROUND WASTE STORAGE TANKS
A corrosion-testing program has been initiated in Purex and Redox storage tnnks to obtain corrosion data on carbon steel and three associated materials in neutralized process wastes. (C.W.H.)
1955-06-28
Enhanced sludge washing evaluation plan
Energy Technology Data Exchange (ETDEWEB)
The Tank Waste Remediation System (TWRS) Program mission is to store, treat, and immobilize highly radioactive Hanford Site waste (current and future tank waste and the strontium/cesium capsules) in an environmentally sound, safe, and cost-effective manner. The scope of the TWRS Waste Pretreatment Program is to treat tank waste and separate that waste into HLW and LLW fractions and provide additional treatment as required to feed LLW and HLW immobilization facilities. Enhanced sludge washing was chosen as the baseline process for separating Hanford tank waste sludge. Section 1.0 briefly discusses the purpose of the evaluation plan and provides the background that led to the choice of enhanced sludge washing as the baseline process. Section 2.0 provides a brief summary of the evaluation plan details. Section 3.0 discusses, in some detail, the technical work planned to support the evaluation of enhanced ...
1994-09-01
Control of the reduction/oxidation potential of Hanford Waste Vitrification Plant feeds
International Nuclear Information System (INIS)
A schematic diagram shows the various processing steps to be performed during feed preparation in the Hanford Waste Vitrification Plant (HWVP). The pretreated NCAW is transferred to the slurry receipt adjustment tank (SRAT) in the HWVP for concentration. Water removed during boildown is collected in the slurry mix evaporator condensate tank (SMECT). After waste treatment the water is returned to the storage tanks for eventual disposal. The pretreated Neutralized Current Acid Waste (NCAW) is concentrated in the SRAT to approximately 125 g waste oxides/ liter. Formic acid is then added at a controlled rate to improve rheological properties and achieve a required reduction/oxidation state. Reflux boiling is initiated and continued for several hours. The concentrated slurry is cooled and pumped to the slurry mix evaporator (SME). In the SME, glass frit is added, and the slurry is further concentrated to achieve a nominal ...
1988-09-11
BALDWIN COUNTY SEPTIC TANK MAINTENANCE DEMONSTRATION PROJECT MX974480
Baldwin County is located on the Gulf of Mexico in Alabama and has a rapidly growing population. Almost 3,000 permits for septic systems are approved annually by by the Baldwin County Health Department. More than 50% of the county's residents rely on septic systems for their d...
...Filter gaskets and seatings; (4) Pumps; (5) Solvent tanks and containers; (6) Water separators; (7) Muck cookers; (8) Stills; (9) Exhaust dampers; (10) Diverter valves; and (11) All Filter housings. (l)...
2009-07-01
...limited to, emission control devices, pumps, filters, muck cookers, stills, solvent tanks, solvent containers, water separators...facility that meets the conditions of § 63.320(g). Muck cooker means a device for heating perchloroethylene-laden...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
The paper presents a computer-aided analysis of the combined use of ventilation and structural heat capacity and insulation as a means of saving air-conditioning power in digital telephone exchanges. It is shown that such savings can be effected by increasing air change with outdoor cool air at night, and when feasible, also in daytime, through the air change unit, in a conventional airconditioning cycle. The total thermal time constant (TTTC) method of calculation used enables the evaluation of daily or seasonal heat-flow balance for a given indoor temperature, considering the tendency of the heat capacity of the building and of envelope components to flatten the fluctuations of this temperature.
1984-12-01
On the long term indoor radon concentration measurements the basement of Japanese hospitals
International Nuclear Information System (INIS)
Long term indoor radon gas measurements using a passive monitor were conducted in the basement rooms of five hospitals, which are built in the Tokyo metropolitan area. The ventilation rate averaged over all hospital was 12.3 air change per hour (ACH). The highest radon concentration was 56.3 Bq/m"3. The value averaged concentration over all hospital and all season was 20 Bq/m"3. But the average of the two hospitals were twice as high as those of three others. Since the total ventilation rate integrated over a day is not different much, the reason of the concentration difference is considered to be the difference in radon emission rate from concrete wall and soil of the each hospital. Though we inquired workers about 'Environmental complaints', it do not show the direct relation between radon and environmental complaints. (author)
International Nuclear Information System (INIS)
Long term indoor radon gas measurements using a passive monitor are now being conducted in the basement HVAC machine rooms of about fifty commercial buildings, which are built in the Tokyo and Nagoya metropolitan area. Ventilation rates are also measured during the monitoring period. The earliest results show that the highest concentration was about twice of the EPA Standards and was obtained at Nagoya in autumn and no clear seasonal change was seen in radon concentration so far, and that the correlation between radon concentration and inverse number of ventilation rate was positive but not high. (orig.). (2 refs., 4 figs., 2 tabs.).
1993-07-04
Energy Technology Data Exchange (ETDEWEB)
Better quality of thermal comfort as well as reduced heat energy demand and accordingly CO{sub 2} emission can be achieved by better heating and ventilation strategies in private buildings. The paper deals with a novel model-based measurement and automation system. It describes the implementation of better strategies under given technical circumstances. (orig.) [German] Durch Verbesserung der Heizungs- und Lueftungsstrategien im privaten Lebensbereich kann sowohl Heizenergie eingespart und damit die CO{sub 2}-Emission verringert, als auch die Raumbehaglichkeit verbessert werden. Der Beitrag behandelt ein modellgestuetztes Mess- und Automatisierungssystem, mit dem die Realisierung der verbesserten Strategien unter gegebenen technischen Randbedingungen praktisch erst moeglich wird. (orig.)
2003-04-01
Malaspina University-College's green building strategy
Energy Technology Data Exchange (ETDEWEB)
This brochure describes the strategy employed by the administration of Malaspina University--College in Nanaimo, British Columbia, to implement energy-efficient plans and integrating systems and plans that would allow the institution to consume less energy, fewer resources and improve the health and well-being of its students and staff. An assessment study to identify the most problematic areas, and to develop a prioritizing strategy for their replacement was the first step, followed by rigorous adherence to a 10- year cyclical replacement schedule. The program includes replacement of rooftop ventilation units, installation of high-performance glazing units to replace single-glazed windows, implementation of an Energy Management System to monitor heating, ventilating and air conditioning systems, and a Power Smart New Building Design and Building Improvements Program. The combined cost avoidance associated with these projects is estimated to ...
2000-01-01
Indoor climate seminar; Sisaeilmastoseminaari
Energy Technology Data Exchange (ETDEWEB)
The national energy research programme LVIS-2000: Future Building Services is concerned with the control of energy use and indoor climate in buildings of the future. The projects were presented at a one day seminar arranged by the Laboratory of Heating and Ventilation of the Technical Research Centre in Finland which is coordinating the programme. The presentations at the seminar were: Impurity emission from materials, Building materials and indoor air quality, analysis of organic compounds in indoor air, effect of the return air, effect of the return air on health and comfort, electric heating as an indoor climate factor, calculations of air flows in ventilated rooms, effect of energy saving measures on hospital hygiene, application of modern aerosol measurement technique on indoor climate research.
1989-12-31
Fingerprint testing of contaminated ventilation extract filter systems at Sizewell B
International Nuclear Information System (INIS)
Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' test systems during the commissioning of Sizewell B. A specific example is presented to demonstrate the ...
Handling of sodium for the FFTF
Based on the High Temperature Sodium Facility (HTSF) experience and the extensive design efforts for FFTF, procedures are in place for the unloading of the tank cars and for the fill of the FFTF reactor. Special precautions have been taken to provide safe handling and to accommodate contingencies in operation. These contingencies include special protective suits allowing personnel to enter and correct conditions arising from fill operations in the course of moving 7.71 x 10/sup 5/ kg (1.7 x 10/sup 6/ lbs) of sodium from the tank cars into the reactor vessel and its loop system.
1978-06-01
Freeze protection valve and system
Energy Technology Data Exchange (ETDEWEB)
The present invention is a device for a solar heating system having a solar collector, a storage tank connected to the solar collector, a pump for circulating liquid from the tank to the solar collector, a supply of liquid at a temperature above freezing and a connection from the supply of liquid to the solar collector for replacing any liquid lost from said solar collector. The device comprises a sensor for sensing the temperature of liquid in the solar collector, and a valve for bleeding liquid from the solar collector when the sensed temperature falls below a predetermined minimum whereby cool liquid in the solar collector is automatically replaced by liquid at a temperature above freezing.
1985-12-10
Effect of tetracycline hydrochloride treatment on the critical thermal maximum of common shiners
Energy Technology Data Exchange (ETDEWEB)
The transfer of fish from field to laboratory facilities or their propagation in closed or restricted systems frequently results in bacterial infection and ultimately large-scale mortality. In attemps to alleviate this problem, we have added tetracycline hydrochloride to the water prophylactically (pretreating tanks before wild fish were added) and therapeutically (treating tanks after bacterial outbreaks were detected.) In the present study, we examined the effect of tetracyline hydrochloride on the critical thermal maximum (CTM) of the common shiner (Notropis cornutus).
1980-01-01
STRESS CORROSION CRACKING SUSCEPTIBILITY OF HIGH LEVEL WASTE TANKS DURING SLUDGE MASS REDUCTION
Energy Technology Data Exchange (ETDEWEB)
Aluminum is a principal element in alkaline nuclear sludge waste stored in high level waste (HLW) tanks at the Savannah River Site. The mass of sludge in a HLW tank can be reduced through the caustic leaching of aluminum, i.e. converting aluminum oxides (gibbsite) and oxide-hydroxides (boehmite) into soluble hydroxides through reaction with a hot caustic solution. The temperature limits outlined by the chemistry control program for HLW tanks to prevent caustic stress corrosion cracking (CSCC) in concentrated hydroxide solutions will potentially be exceeded during the sludge mass reduction (SMR) campaign. Corrosion testing was performed to determine the potential for CSCC under expected conditions. The experimental test program, developed based upon previous test results and expected conditions during the current SMR campaign, consisted of electrochemical and mechanical testing to determine the susceptibility of ASTM A516 ...
2007-10-18
Low-activity waste envelope definitions for the TWRS Privatization Phase I Request For Proposal
Energy Technology Data Exchange (ETDEWEB)
Radioactive waste has been stored in large underground storage tanks at the Hanford Site since 1944. Approximately 212 million liters of waste containing approximately 240,000 metric tons of processed chemicals and 177 mega-curies of radionuclides are now stored in 177 tanks. These caustic wastes are in the form of liquids, slurries, saltcakes, and sludge. In 1991, the Tank Waste Remediation System (TWRS) Program was established to manage, retrieve, treat, immobilize, and dispose of these wastes in a safe, environmentally sound, and cost-effective manner. The Department of Energy (DOE) has believes that it is feasible to privatize portions of the TWRS Program. Under the privatization strategy embodied in the Request for Proposal (RFP), DOE will purchase services from a contractor-owned, contractor-operated facility under a fixed-price contract. Phase I of the TWRS privatization strategy is a proof-of-concept/commercial ...
1996-11-01
Energy Technology Data Exchange (ETDEWEB)
This document is the third annual revision of the plans and schedules for implementing the Federal Facility Agreement (FFA) compliance program, originally submitted in 1992 as ES/ER-17&D1, Federal Facility Agreement Plans and Schedules for Liquid Low-Level Radioactive Waste Tank Systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee. This document summarizes the progress that has been made to date in implementing the plans and schedules for meeting the FFA commitments for the Liquid Low-Level Waste (LLLW) System at Oak Ridge National Laboratory (ORNL). Information presented in this document provides a comprehensive summary to facilitate understanding of the FFA compliance program for LLLW tank systems and to present plans and schedules associated with remediation, through the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) process, of LLLW tank systems that have been removed from ...
1995-06-01
Energy Technology Data Exchange (ETDEWEB)
The two tank (125,000kl each) foundations under construction are as large as 85m in diameter, and the north-side tank is to be placed over a sharper slope. The tanks are greatly different in their height from the rockbed since they are to be placed at the same level. For reduction in construction cost and time, a pile foundation design is chosen as the basic concept for foundation construction. After an overall evaluation of stability upon exposure to seismic torsion and of the deformation characteristics of piles and concrete slabs, a total pile foundation design with rock debris replaced with crushed rock is determined to be the design to be adopted. Since the piles to be driven in are greatly different in length, error in the pile supporting force will be too grave under the conventional pile landing control system. Therefore, a high-accuracy pile landing control system is employed, established after a rapid load test in ...
1998-09-05
USDA Finances Wind for Rural Economic Development (Poster)
Energy Technology Data Exchange (ETDEWEB)
To foster rural economic development and growth, Congress passed the Renewable Energy Systems and Energy Efficiency Improvements Program as Section 9006 of the 2002 Farm Bill. This program provides financial assistance to farmers, ranchers, and rural small businesses to purchase renewable energy systems or make energy efficiency improvements. The Rural Business and Cooperative Services of the United States Department of Agriculture (USDA) administers this program. This conference poster provides an overview of Section 9006.
2005-05-01
The use and value of information systems as evaluated by dairy and specialty crop farm managers.
Little recent research is available about where specific types of farm managers search for information about better production practices. The objective of this study was to investigate what information sources managers used and how they rated the usefulness of each source. The authors administered mail questionnaires to probability samples from sampling frames they developed for four groups: dairy and fresh market vegetable producers from Wisconsin and berry and nursery producers from a multistate region. Questionnaire items asked operation managers to check off, from a list of information sources, those that they used in the last year to learn about new equipment or procedures to improve their operations and then to rate the usefulness of each source. In the last year, nursery, dairy, and berry managers most often used information from print media (63% to 84%), followed by other farmers (50% to 80%). Fresh market vegetable growers used conferences (60%) most ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper shows and describes the actions and methodologies adopted in commercialization of rural electrification projects in Parana State, Brazil. The actions evaluated aims to feasible the techniques to farm owners provides them properties with electric power. 7 figs., 2 tabs., 1 ref.
1986-12-31
Renewable resources - prospects for the chemicals industry
International Nuclear Information System (INIS)
Improved boundary conditions for the cultivation and utilization of renewable feedstocks in Europe as well as advances in the manufacture and use of intermediate products, special and fine chemicals, and new materials on this basis were the topics of a second symposium, organized this time by Hoechst AG, together with the federal ministry of food, agriculture and forestry, in Frankfurt-Hoechst on May 5th and 6th. With more than 300 attendants from the sectors politics, farming, industry, science and administration, the meeting again encountered great interest. (orig.).
UK PubMed Central (United Kingdom)
Broiler chickens from eight commercial farms in Southern Finland were analyzed for the structure of their gastrointestinal microbial community by a nonselective DNA-based method, percent G+C-based...Full Text Available
2001-12-01
Organic livestock production in Uganda: potentials, challenges and prospects.
Development in organic farming has been stimulated by farmers and consumers becoming interested in healthy food products and sustainable environment. Organic agriculture is a holistic production management system which is based on the principles of health, ecology, care, and fairness. Organic development in Uganda has focused more on the crop sector than livestock sector and has primarily involved the private sector, like organic products export companies and non-governmental organizations. Agriculture in Uganda and many African countries is predominantly traditional, less mechanized, and is usually associated with minimum use of chemical fertilizers, pesticides, and drugs. This low external input agriculture also referred to as "organic by default" can create basis for organic farming where agroecological methods are introduced and present an alternative in terms of intensification to the current low-input/low-output systems. Traditional ...
2011-01-12
Optimising nutrient use efficiency in beef cattle grazing lowland semi-natural pastures
Environmental Research Database
DescriptionThe switch from production-linked to environmental payments has focussed attention on the environmental impacts of farming. There is a growing awareness of the need to reduce the contamination of air with carbon dioxide, methane, ammonia and nitrogen gases (which contribute to the greenhouse effect) and to prevent the contamination of soil and water with excessive amounts of nitrogen, phosphorus and potassium. As beef production moves to become more sustainable and fully integrated with the wide [continued...
2007-01-30
Methane fermentation of agricultural wastes and domestic animal's wastes
Energy Technology Data Exchange (ETDEWEB)
Cattle and pig wastes, orange peels, compost, and grain husks were hydrolyzed in an alkaline medium to investigate the CH4 generation capacity. The respective CH4 production capacities from pig wastes and rice hulls were approximately 1 and approximately 0.1 L/g. The CH4 produced can be used to supplement energy requirements of farms.
1981-01-01
UK PubMed Central (United Kingdom)
A nationwide surveillance for antimicrobial susceptibility in Escherichia coli strains isolated from food-producing animals in Japan was conducted from 1999 to 2002. Eighteen cefazolin-resistant...Full Text Available
2005-08-01
Drying of medicinal plants with solar energy utilization
Energy Technology Data Exchange (ETDEWEB)
In the paper, a potential of solar energy for drying of medicinal plants in Polish conditions is estimated and development of solar drying technologies is presented. The results of economic assessment of flat-plate solar collectors applied for drying of medicinal plants on a farm are promising. In some specific conditions, e.g. drying of wild grown medicinal plants in remote areas, even application of photovoltaic modules for driving of a fan of a solar dryer is a profitable option and enables easy control of the drying air temperature.
1997-10-01
Dounreay: an alternative development
International Nuclear Information System (INIS)
With the Government decision to phase out the Fast Reactor at Dounreay there is a need to find alternative employment in the area. Traditionally Caithness is an area of farming, fishing and tourism which could be damaged if Dounreay were to be made a nuclear waste repository. The suggestion is that Dounreay should become a centre for research, development and subsequent manufacture of renewable energy sources and devices to harness renewable energy. The Scottish coastline has potential for wind and wave power developments and this could lead to a whole industry in the future. (UK).
1991-01-01
Animal manure digestion systems in central Europe
Energy Technology Data Exchange (ETDEWEB)
This work provides an overview of existing plants in Europe and describes the substrates being used. It focuses on the individual farm-scale and community plants, as these are the two main types now being built. It also describes plants currently under construction, especially in Germany and Denmark, where the major efforts are focused. A description of how the technique has developed over the past few years, its current state of development, the motivation and economic balance, and the substrate characteristics, is presented.
1996-01-01
A non-invasive approach for the determination of rumen pH
Environmental Research Database
DescriptionAt present, measurement of rumen pH for differnt diets and feeding regimes is only possible through direct sampling of the rumen fluid. Such invasive procedures are not practical at the farm level and they have ethical implications for research programmes. This approach also has limitations to its reliability due to spatial variations in acidity within the rumen. Mathematical modelling offers a non-invasive real-time alternative for monitoring rumen pH, and the purpose of the research propose [continued...
2004-01-31
Ozone hazards incurred in #gamma#-plant operation
International Nuclear Information System (INIS)
The irradiation of air produces some toxic gases such as ozone, nitric oxide, nitrogen dioxide, nitrogen trioxide, nitrogen tetroxide, nitric anhydride and nitrous oxide. Of these gases, ozone is the most important because of its toxicity and may be produced in such quantities as to constitute a health hazard within the irradiation room. The toxicity, and explosive characteristics of ozone and quantitative aspects of ozone production are discussed and ventilation requirements considered. (U.K.).
Energy Technology Data Exchange (ETDEWEB)
This paper is dedicated to the numerical study of natural ventilation in a room through a large external opening using the CFD code Fluent. Bidimensional numerical simulations are performed for wind speeds up to 5.55 m-s{sup -1} (20 km-h{sup -1}). We propose a two-step solution procedure with grid refinement. When combined with appropriate thermal boundary conditions, this technique appears very efficient at limiting local convergence problems. Through an analysis of the flow pattern in the cavity, we qualitatively explain those results and define a critical Archimedes number. Calculated air change rates are compared to values deduced from empirical correlations of the literature. Agreement is in general poor, which can be explained by the differences between the conditions of our simulations and those of the experiments that lead to those correlations. However, from our simulations, we derived very clear correlations between the air change coefficient and the ...
1998-02-01
Energy Technology Data Exchange (ETDEWEB)
A research report describes the energy efficiency techniques to be employed in designing a building which is ``green``. Topics covered include building fabric performance, ventilation and infiltration, passive solar design, heating systems and controls, hot and cold water provision, lighting and electrical appliances. (UK)
1993-12-31
Development of High-Efficiency Low-Lift Vapor Compression System - Final Report
Energy Technology Data Exchange (ETDEWEB)
PNNL, with cofunding from the Bonneville Power Administration (BPA) and Building Technologies Program, conducted a research and development activity targeted at addressing the energy efficiency goals targeted in the BPA roadmap. PNNL investigated an integrated heating, ventilation and air conditioning (HVAC) system option referred to as the low-lift cooling system that potentially offers an increase in HVAC energy performance relative to ASHRAE Standard 90.1-2004.
2010-03-31
Atlas of room air flow; Raumstroemungsatlas
Energy Technology Data Exchange (ETDEWEB)
Within the framework of the IEA project Annex 20 - Airflow patters within buildings , an airflow data base was built up as a prototype. It enables airflow profiles, comfort and interior air quality to be studied without having to carry out a 1:1 experiment or having to run an expensive simulation code. The data base contains a number of pre-calculated room airflow profiles with their associated depictions of air quality and risks of drafts for given premises and for different ventilation systems. figs., tabs., refs.
1994-12-31
Atlas of nuclear medicine imaging
Energy Technology Data Exchange (ETDEWEB)
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
The invention concerns a method for the graduated introduction of finely-particulate and especially pulverously-particulate solid substance, in particular coal dust, from a pressurised proportioning tank containing a supply of solid matter into an industrial furnace with several supply points, in particular a shaft furnace such as a blast furnace or a cupola furnace, the solid matter being conveyed to the individual supply points in a flow of carrier gas heavily charged with solid matter, through a separate transport line for each supply point, the carrier gas being conveyed to the lower end section of the proportioning tank in a current which causes a local loosening in the lower section of the supply of solid matter, with the transport lines opening into the loosened area, whilst the proportioning tank that contains the solid matter is weighed continuously, the actual weight of the proportioning tank ...
1987-09-09
Energy Technology Data Exchange (ETDEWEB)
CNG vehicles suffer from an uncontrolled temperature rise of the gas inside the tank during the filling process and heat exchange with the environment leads to variable filling levels. A partly filled tank reduces the range of CNG vehicles and works as a impediment to the spreading of environmentaly more friendly CNG vehicles. The increase of the pressure inside the tank combined with a prolongation of the filling time beyond three minutes can reduce the deficit of the filling process. For economic reasons the time required for refuelling should be as short as possible without the need to operate the filling station with a critical pressure. To meet this target the current technique requires further improvement. (orig.) [Deutsch] Die betriebliche Praxis bei Tankvorgaengen von Erdgasfahrzeugen zeigt, dass waehrend des Tankvorganges die Temperatur des getankten Erdgases im Fahrzeugtank ansteigt. Waehrend und nach Beendigung ...
1998-07-01
Commissioning and operation of new liquid poison injection based shut down system in TAPP-3 and 4
International Nuclear Information System (INIS)
Shut Down System - 2 (SDS - 2) of TAPP-3 and 4 works on the principle of rapid injection of gadolinium nitrate poison solution into bulk moderator in calandria using high pressure helium to shut down the reactor. This is a new system, in the context of Indian PHWRs, designed, engineered, commissioned and being operated in TAPP-3 and 4. The system design incorporates passive features such as floating polyethylene ball with ball-ball seat arrangement and locked open isolation ball valves with key interlock arrangement. This arrangement eliminates active valves downstream of poison tanks during SDS - 2 actuation. A series parallel arrangement of fast acting pilot controlled air operated valves, which keep the high pressure helium isolated from poison tanks in poised state, are the only active components. During commissioning and initial period of operation of TAPP-4, problems were encountered and were resolved by suitable modifications and the ...
2006-11-13
International Nuclear Information System (INIS)
Natural convection flow is established in KMRR (Korea Multi-Purpose Research Reactor) reflector tank at the loss of reflector circulator. To simulate the reflector tank natural convection flow with high temperatures at the inner shell and bottom plate due to nuclear heating, experimental and numerical studies in an open cavity with 'L' type heated wall made by the combination of a vertical and horizontal plate were performed. It was confirmed through these studies that the heat transfer rates were highest at the lower region of the vertical plate and the inlet region of horizontal plate and comparatively high at the middle portion of both plates. The heat transfer rate distribution of this trend shows a desirable trend for the effective natural convection cooling of KMRR reflector tank. It was also confirmed that the average Nusselts numbers at the 'L' type heated wall were lower than those obtained from the existing ...
1991-10-26
Large temperature differential thermal storage system. Its design and evaluation
Energy Technology Data Exchange (ETDEWEB)
A large temperature differential (10K) thermal storage system in a small (4400 m{sup 2}) 8-storey office building is discussed and the monitoring results are analyzed in comparison with computer simulations. Requirements were a comfortable indoor environment and system cost effectiveness. Out of four potential system concepts, the Large Temperature Differential System was chosen. It comprises a flat-type thermal stratification heat storage tank in the under floor pit of the building as the heat source for a variable flow heat pump chiller. The heat sink is a set of serially connected air handling and fan coil units. The tank`s capacity is sized for one day operation and is made as large as possible to shift the electricity demand to night time. To avoid a large size and high cost, the water temperature differential was enlarged. The role of Tokyo Electric Power Company (TEPCO) was to develop the chiller and its control system. It is concluded ...
1996-07-01
Kinetics of absorption of trace iodine vapor in aqueous solution of sodium hydroxide, (2)
International Nuclear Information System (INIS)
A liquid column was used for the experiments reported in Part 1. However, it only gives the observation of the effect of fast reaction because the liquid flow was controlled to uniform laminar flow and the contact is limited to short time of around 10 ms. In practical absorbing operation, turbulence is involved in liquid flow, and the residence time for contact is long. Hence, the absorption of trace iodine in the purified air has been experimented by using a constant interface area type stirred absorption tank. Prior to the experiment, the characteristics of the absorption tank was investigated by conducting pure carbon dioxide absorption test with purified water. It gave the conclusion that the tank was sufficiently usable for fundamental researches. In short contact time absorption, the iodine dissolved and absorbed in liquid phase is affected by reaction of hypoiodous acid and poly-iodide ion formation due to hydrolysis ...
1978-01-01
Energy Technology Data Exchange (ETDEWEB)
Bench-scale batch equilibration tests have been conducted with supernatants from two underground tanks at the Melton Valley Storage Tank (MVST) Facility at Oak Ridge National Laboratory (ORNL) to determine the effectiveness of selected ion exchangers in removing cesium, strontium, and technetium. Seven sorbents were evaluated for cesium removal, nine for strontium removal, and four for technetium removal. The results indicate that granular potassium cobalt hexacyanoferrate was the most effective of the exchangers evaluated for removing cesium from the supernatants. The powdered forms of sodium titanate (NaTiO) and cystalline silicotitanate (CST) were superior in removing the strontium; however, for the sorbents of suitable particle size for column use, titanium monohydrogen phosphate (TiHP {phi}), sodium titanate/polyacrylonitrile (NaTiO-PAN), and titanium monohydrogen phosphate/polyacrylonitrile (TiP-PAN) gave the best results and were about ...
1995-06-01
Actinide, strontium, and cesium removal from Hanford radioactive tank sludge
International Nuclear Information System (INIS)
A pretreatment flowsheet was tested for separating key radionuclide components from the sludge stored in one of the high level waste tanks (B-110) at the Hanford Site; this sludge resulted primarily from the bismuth phosphate process, which was one of the three major plutonium separation processes used at Handford. This test involved (1) washing with water, (2) caustic leaching, (3) acid dissolution, (4) separation of transuranic elements (TRUs) by extraction with octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide(CMPO), (5) separation of Sr by extraction with di-t-butylcyclohexano-18-crown-6, (6) separation of Cs from the acid-dissolved sludge solution by treatment with ammonium molybdophosphate (AMP), and (7) separation of Cs from the sludge wash and caustic leach solutions by ion exchange using a phenol-formaldehyde resin (CS-100). The results of the radionuclide separation steps indicated that the proposed flowsheet is a viable approach to pretreating ...
Vacuum leak problem in low energy of pelletron
International Nuclear Information System (INIS)
During unit wise conditioning of unit 8, the vacuum started deteriorating inside the tube after a spark. The RGA reading was taken and it was found out that residual gas inside tube was sulphur hexafluoride. A leak was detected in second tube of unit number eight in between electrode 6 to 8. Leak was sealed with the sealant. Again leak check was done and no leak was found. The tank was closed and conditioning was started again. During the same unit number eight conditioning, leak developed again followed by a spark. So the damaged tube was replaced with a new accelerator tube. During the installation time the alignment of the machine was taken care. Again leak checking was done and the tube was baked properly. The tank was closed again and this particular unit was conditioned for about four days. The maximum voltage it has attained was 1.1 MV. (author)
The MiniBooNE detector technical design report
Energy Technology Data Exchange (ETDEWEB)
The MiniBooNE experiment [1] is motivated by the LSND observation, [2] which has been interpreted as {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, and by the atmospheric neutrino deficit, [3,4,5] which may be ascribed to {nu}{sub {mu}} oscillations into another type of neutrino. MiniBooNE is a single-detector experiment designed to: obtain {approx} 1000 {nu}{sub {mu}} {yields} {nu}{sub e} events if the LSND signal is due to {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, establishing the oscillation signal at the > 5{sigma} level as shown in Fig. 1.1; extend the search for {nu}{sub {mu}} {yields} {nu}{sub e} oscillations significantly beyond what has been studied previously if no signal is observed; search for {nu}{sub {mu}} disappearance to address the atmospheric neutrino deficit with a signal that is a suppression of the rate of {nu}{sub {mu}}C {yields} {mu}N events from the expected 600,000 per year; measure the oscillation parameters as shown in Fig. 1.2 if ...
2003-04-18
Subcritical measurements with a cylindrical tank of Pu-U nitrate
Energy Technology Data Exchange (ETDEWEB)
This series of measurements with a mixed Pu-U nitrate solution (280 g Pu/liter, 180 g U/liter) in a 35.54-cm-diam cylindrical tank provides a wide variety of experimental data for subcritical configurations that can be used to verify calculational methods and nuclear data. The Pu contained 7.85 wt% {sup 240}Pu and the uranium was natural uranium. The measurements performed were: inverse count rate, prompt neutron decay constants, inverse kinetics, and frequency analysis by the {sup 252}Cf source driven method. These data are presented in sufficient detail that the results of the experiments can be calculated directly. For purposes of extrapolating to the delayed critical height the ratio of spectral densities was linear with height and thus provided the best estimate of critical height.
1997-04-01
Solids distribution in tall tanks
British Library Electronic Table of Contents (United Kingdom)
Abstract Uniformly distributing slurry solids in -tall- (-2:1 aspect ratio) process vessels is a significant challenge in the chemical industry. This work determined the performance of various multi-tier agitation systems in uniformly distributing a settling solid throughout water in a -tall- laboratory vessel. It used a 0.445-m ID Plexiglas tank, with a slurry height of 0.889-m, to determine how solids distribution changes with solids loading (wt.%), impeller speed, and impeller type. Some impeller types uniformly distributed the solids even before energy input exceeded 1.00-W/kg. Significantly higher energy improved solids distribution little because flow within the vessel eventually became choked.
2011-01-01
Rocky Mountain Arsenal, Basin F liquid storage tank spill, draft risk assessment
Energy Technology Data Exchange (ETDEWEB)
The scope of this RA is limited to the evaluation of potential human health risks associated with a failure event of a tank containing Basin F liquid. Section 1.0 contains an introduction to the health risk assessment. Section 2.0 describes the site history, location, and land use. Section 3.0 provides a brief description of exposure pathways and potention receptors. Section 4.0 describes the sources of data used and identifies chemicals of concern. Section 5.0 discusses the toxicity of concern. Section 6.0 explains the methods used for calculation of carcinogenic risks and the noncarcinogenic hazard indexes. Section 7.0 describes uncertainties inherent in the current methodology used to determine potential human health risks. Section 8.0 presents a summary of results and conclusions. Section 9.0 includes the references cited.
1993-04-01
Radon concentration measurements at water reservoirs
International Nuclear Information System (INIS)
Ground water is treated in the Czech Republic so that small water tanks are built above each water source to serve the primary ground water treatment; water so pretreated is then concentrated in large basins for subsequent treatment. Some water tanks where the first contact of the ground water with air takes place were selected as sites predisposed to radon accumulation. The examination was carried out near the town of Jihlava, where the bedrock contains slightly elevated radium concentrations. The average radon concentrations lay within the region of 2-4 kBq/m"3; the instantaneous values, however, exhibited appreciable periodical variations during the day. The relatively high radon concentrations will not pose a marked hazard for the personnel because the employees only reside at the sites in question for 10 to 15 minutes within 2 days, not for the whole working day
1998-09-09
Measurement of liquid nitrogen level by radiation
Energy Technology Data Exchange (ETDEWEB)
The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)
1995-07-01
Fuel cell hybrid taxi life cycle analysis
British Library Electronic Table of Contents (United Kingdom)
A small fleet of classic London Taxis (Black cabs) equipped with hydrogen fuel cell power systems is being prepared for demonstration during the 2012 London Olympics. This paper presents a Life Cycle Analysis for these vehicles in terms of energy consumption and CO2 emissions, focusing on the impacts of alternative vehicle technologies for the Taxi, combining the fuel life cycle (Tank-to-Wheel and Well-to-Tank) and vehicle materials Cradle-to-Grave. An internal combustion engine diesel taxi was used as the reference vehicle for the currently available technology. This is compared to battery and fuel cell vehicle configurations. Accordingly, the following energy pathways are compared: diesel, electricity and hydrogen (derived from natural gas steam reforming). Full Life Cycle Analysis, usin...
2011-01-01
Device for energy-saving heating of fuel in the fuel supply for an internal combustion engine
Energy Technology Data Exchange (ETDEWEB)
The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat exchanger to be short-circuited depending on the fuel temperature.
1981-02-10
Design on SDS2 on-line poison concentration monitoring in CANDU
Energy Technology Data Exchange (ETDEWEB)
At the reference plant (Wolsung unit No. 1) a manual poison sampling system is provided to periodically sample gadolinium from each tank and analyze it in the laboratory to provide assurance that adequate poison concentration in each tank is maintained. The AECB required a continuous, on-line monitoring system. On Wolsung unit No. 2, process piping adapter and new instrument loops added to the Liquid Injection Shutdown System(LISS) which is part of SDS2. The new instrument loops continuously monitor SDS2 poison conductivity and initiate an alarm when the poison concentration is too low. 8 refs., 1 fig. (author).
1996-10-01
Concentration of Melton Valley Storage Tank surrogates with a wiped film evaporator
Energy Technology Data Exchange (ETDEWEB)
This report describes experiments to determine whether a wiped film evaporator (WFE) might be used to concentrate low-level liquid radioactive waste (LLLW). Solutions used in these studies were surrogates that contain no radionuclides. The compositions of the surrogates were based on one of Oak Ridge National Laboratory`s (ORNL`s) Melton Valley Storage Tanks (MVSTs). It was found that a WFE could be used to concentrate LLLW to varying degrees by manipulating various parameters. The parameters studied were rotor speed, process fluid feed temperature and feed rate, and evaporator temperature. Product consistency varied from an unsaturated liquid to a dry powder. Volume reductions up to 68% were achieved. System decontamination factors were consistently in the range of 10{sup 4}.
1994-08-01
A novel domestic electric water heater model for a multi-objective demand side management program
Energy Technology Data Exchange (ETDEWEB)
This paper presents a novel domestic hot water heater model to be used in a multi-objective demand side management program. The model incorporates both the thermal losses and the water usage to determine the temperature of the water in the tank. Water heater loads are extracted from household load data and then used to determine the household water usage patterns. The benefits of the model are: (1) the on/off state of the water heater and temperature of the water in the tank can be accurately predicted, and (2) it enables the development of water usage profiles so that users can be classified based on usage behaviour. As a result, the amount of ancillary services and peak shaving that can be achieved are accurately predictable and can be maximized without adversely affecting users. (author)
2010-12-15
Energy Technology Data Exchange (ETDEWEB)
In order to study nuclear criticality safety related to the development of fast breeder technology, /sup 252/Cf-source-driven neutron noise analysis measurements were performed with a Pu-U nitrate solution in a slab tank of various heights and thickness varying 11.43 cm to 19.05 cm. The results and conclusions of these experiments are (1) a capability to measure the subcriticality of a multiplying system of slab geometry to a k/sub eff/ as low as 0.7 was demonstrated, (2) calculated neutron multiplication factors agreed with those from the experiments within approx.0.02, and (3) the applicability of the method for plutonium solution systems was demonstrated. This paper describes measurements in which the height of the slab was varied for a fixed thickness and the thickness varied for a fixed height, which are the first applications of this measurement method to slab geometry.
1987-08-01
Techno-economic assessment of anaerobic digestion systems for agri-food wastes
Energy Technology Data Exchange (ETDEWEB)
Activities in British Columbia's Fraser Valley generate an estimated 3 million tones of agriculture and food wastes annually, of which 85 per cent are readily available for anaerobic digestion. The potential for energy generation from biogas through anaerobic digestion is approximately 30 MW. On-farm manure-based systems represent the most likely scenario for the development of anaerobic digestion in British Columbia in the near future. Off-farm food processing wastes may be an alternative option to large centralized industrial complexes. Odour control, pathogen reduction, improved water quality, reduced greenhouse gas emissions and reduced landfill usage are among the environmental benefits of anaerobic digestion. The economical benefits include power and heat generation, biogas upgrading, and further processing of the residues to produce compost or animal bedding. This paper described a newly developed anaerobic digestion (AD) ...
2010-07-01
Fish schooling as a basis for vertical axis wind turbine farm design
International Nuclear Information System (INIS)
Most wind farms consist of horizontal axis wind turbines (HAWTs) due to the high power coefficient (mechanical power output divided by the power of the free-stream air through the turbine cross-sectional area) of an isolated turbine. However when in close proximity to neighboring turbines, HAWTs suffer from a reduced power coefficient. In contrast, previous research on vertical axis wind turbines (VAWTs) suggests that closely spaced VAWTs may experience only small decreases (or even increases) in an individual turbine's power coefficient when placed in close proximity to neighbors, thus yielding much higher power outputs for a given area of land. A potential flow model of inter-VAWT interactions is developed to investigate the effect of changes in VAWT spatial arrangement on the array performance coefficient, which compares the expected average power coefficient of turbines in an array to a spatially isolated turbine. A geometric arrangement based on the ...
2010-09-01
Bioaccumulation of trace metals in farmed fish from South China and potential risk assessment
British Library Electronic Table of Contents (United Kingdom)
Concentrations of trace metals were determined in water, sediment, fish feed and two species of farmed fish, pompano and snapper, collected from Daya Bay and Hailing Bay of South China in July 2007 and January 2008. Total average concentrations of Cu, Pb, Zn, Cd, Cr, Hg and As were 1.6, 2.7, 27.3, 0.025, 0.62, 0.18 and 0.59?g/gdrywt in pompano and 1.5, 2.6, 23.6, 0.020, 0.55, 0.22 and 0.53?g/gdrywt in snapper. In general, the concentrations of all target metals except Hg were positively correlated with lipid contents whereas negative correlations were observed between the metal concentrations and fish body weights. Model calculation indicated that dietary uptake of Zn and Cd predominate their accumulation in snapper, accounting for 99.9% and 98.2% of the total inputs. Risk ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
This report made for the Swiss Federal Office of Energy (SFOE) discusses the conception, planning and construction of an easy-to-operate pilot heating plant that uses chicken litter as its fuel. The plant, which is installed at a chicken farm in Boesingen, Switzerland, produces 250 - 350 kW and not only supplies heat for two chicken sheds and two households, but also provides energy for a drying plant in summer. The results of measurements made on emissions are discussed and, within the framework of an eco-balance analysis, comparisons are made between the direct use of the droppings as manure or as a fuel. The cost-effectiveness of the plant is examined and the influence of plant size and other factors discussed. Further, legal questions concerning the use of chicken litter as a fuel for heating installations are discussed; the use of the droppings as a fuel is not foreseen in the legislation concerning water protection and airborne emissions of pollutants. ...
2001-07-01
The use of noninvasive mechanical ventilation in COPD with severe hypercapnic acidosis
British Library Electronic Table of Contents (United Kingdom)
SummaryStudy Objectives: To compare the effect of noninvasive mechanical ventilation (NIV) in severely acidotic with mildly acidotic patients with acute hypercapnic chronic obstructive lung disease (COPD).Design: Comparison of NIV in consecutively enrolled patients with acute hypercapnic COPD with mild (pH 7.25-7.35) or severe (pHPaCO2, duration of NIV treatment, length of stay in hospital and survival.Results (meadian (IQR)): Twenty-nine patients had 36 episodes of acute hypercapnic respiratory failure: Seventeen with pHPaCO2 improve (12 (6-34) vs 12 (4-28)h, respectively, Formula Not Shown ), with similar duration of NIV treatment (60 (35-96) vs 68 (36-48)h, respectively, Formula Not Shown ) and hospital length of stay (8 (7-18) vs 9 (5-17) days, respectively, Formula Not Shown ). Overal...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
A lower energy efficiency standard for buildings (EPC) can have a negative impact on thermal comfort and indoor air quality. Cooperation and integrated design are preconditions for a correct use, installation and maintenance of heating and ventilation systems in buildings. [Dutch] Er komt steeds meer kritiek op de wijze waarop in ons land woningen en gebouwen worden gebouwd. Op dit moment is het vooral woonhuisventilatie waar veel om te doen is. Van beleidsmakers tot aannemers en van Consumentenbond tot gezondheidsdiensten; iedereen vraagt zich af of we met vergaande isolatie onze woningen en gebouwen nog wel leefbaar houden. In dit artikel wordt een pleidooi gehouden voor onderlinge samenwerking en integraal ontwerp als randvoorwaarden voor een goede toepassing, installatie en onderhoud van verwarmings- en ventilatiesystemen in gebouwen.
2006-09-15
International Nuclear Information System (INIS)
From the indoor radon problem arises a great challenge for the radiation protection of the population. The soil can be considered as the only source for high radon concentrations in buildings. The contribution of common building materials to high indoor concentrations with a range of 30 Bq/m"3 is negligible low. Therefore building materials for radon mitigation should be judged by their tightness against diffusive radon and not by their radon exhalation rate. Also isolation materials for mitigation should be radon tight. The radon diffusion coefficient describes the physical processes in relatively homogeneous samples. The diffusion coefficient D and the diffusion length R are very exactly determined by a self engineered measuring method. The range of D reaches from D = (0.0005 to 2.35) . 10"-"6 m"2/s for building materials and from D = (0.07 to < 10"-"6) . 10"-"6 m"2/s for isolation materials. Applicable mitigation measures like increased ventilation rates, ...
Airflow modelling and fire smoke propagation in the new Ecole Polytechnique building
Energy Technology Data Exchange (ETDEWEB)
A study was conducted to predict indoor ventilation, smoke movement and fire propagation in a new building currently under construction at the Ecole Polytechnique de Montreal. It was conducted in response to concerns regarding the impact that air quality, in normal operation conditions, and smoke concentration, in the event of a fire, may have on occupants of a building. A detailed three-dimensional model of the new building was constructed using the NURBS-based modeler, Rhino. Simulations of fire propagation and airflow ventilation were performed in different areas of the building. The flow pattern data was analyzed using the computational fluid dynamics (CFD) program called FLUENT. It predicted air flow conditions and estimated the mean age of air (MAA) in the room. Real-world geometries, such as diffuser inlets, have a significant impact on overall fluid flow behaviour and are necessary for this type of analysis. The fire simulation was ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
Urban type R D (research and development) facilities have research institute functions which are not desirable to coexist in a city as compared with suburban R D facilities. Therefore careful consideration must be given to environmental protection. KSP is the first large scale urban type R D facility in Japan. The planning and construction have been made with the theme of realization of flexibility in architecture and mechanical planning as well as realization of environmental integrity. To achieve the target so-called technical slit is built at the center of the building to provide a void space for securing natural ventilation. It is effective for provision of internal mechanical spaces without spoiling urban View air exhaust from laboratories natural ventilation for underground parking lots and decrease of damage by strong wind on the ground level. Standards are established and organization is formed for environmental administration to ...
1991-12-05
Utilization of wastes from coal-fired power plants for soil improvement and plant nutrition
International Nuclear Information System (INIS)
The reduction of emission from power plants of the public power industry inevitably leads to more and more residual products being obtained which require utilization. Traditionally, the building and building materials industry as well as, for a number of years, the gypsum industry have been the main customers processing these residual materials. To avoid having to tip them at landfills that are in short supply already, further uses are sought; so, for instance, in farming to ameliorate soil and fertilize plants. Relative to this subject, proposals are already available which are presented as lectures at the conference and discussed, together with practical knowledge and new investigation results. (BBR).
1991-10-08
The effect of high voltage transmission lines on agricultural land values in minnesota
Energy Technology Data Exchange (ETDEWEB)
Overhead, high power transmission lines have secured rights of way on agricultural lands in Minnesota. The economic impact of such utility crossings, including effects on land price, was investigated. Sale records and survey data were analyzed. Buyers, sellers, and brokers were interviewed concerning inconvenience, radio interference, appearance, and loss of irrigation possibilities due to the transmission lines. In nine affected sales, there was only one case in which less money was indicated for the farm because of the presence of a transmission line.
1981-04-01
The effect of high voltage transmission lines on agricultural land values in Minnesota
Energy Technology Data Exchange (ETDEWEB)
Overhead, high power transmission lines have secured rights of way on agricultural lands in Minnesota. The economic impact of such utility crossings, including effects on land price, was investigated. Sale records and survey data were analyzed. Buyers, sellers, and brokers were interviewed concerning inconvenience, radio interference, appearance, and loss of irrigation possibilities due to the transmission lines. In nine affected sales, there was only one case in which less money was indicated for the farm because of the presence of a transmission line.
1981-04-01
Poultry Production | Ag 101 | Agriculture | US EPA
... Poultry Production | Ag 101 | Agriculture | US EPA Ag 101 provides a brief overview of poultry production in the U.S.... Poultry Production Jump to main content. Ag 101 Contact Us Search: All EPA This Area You are here: EPA Home Agriculture ...Ag 101 Poultry Production Poultry Production Poultry production is an important and diverse component of American agriculture. Poultry products including eggs, chicken and turkey meat are ... In 1997, nearly 99,700 farms were producing poultry and poultry products (egg, broiler, and turkey; NASS/USDA). While broiler chicken ...
Energy Technology Data Exchange (ETDEWEB)
This article outlines the use of gasifiers during World War II and how, with soaring fuel prices, producer gas may provide an alternate energy path for agribusiness and farms today. In the last few years, the University of California has become a focus of producer gas research in the US. Biomass fuels used include crushed walnut shells, fruit pits, cereal straw and corn cobs. Particle size, moisture content and slagging create problems and the right kind of gas producer must be used to obtain reliable conversion to producer gas.
1980-09-08
Fluidized-bed energy technology for biomass conversion
Fluidized bed technology was experimentally evaluated for the combustion and gasification of cotton gin waste. The isothermal bed temperatures in the reactors could be maintained below the ash fusion point of the waste. Raw stripper harvested cotton gin trash could be metered directly into the fluidized-bed reactors indicating that little feed preparation is required. H and CO were the primary products of gasification, and approximately 3200-400 Btu of gas were produced per lb of cotton gin waste. These techniques offer the potential of providing small-scale energy conversion systems for use on farms.
1980-01-01
Energy production on farms. Sustainability of energy crops
International Nuclear Information System (INIS)
In this article the results of a study on sustainability of energy crops are discussed. Contribution to the reduction of the greenhouse effect and other environmental effects were investigated for the Netherlands. The study assumed that energy crops are grown on set-aside land or grain land. Generating electricity and/or heat from hemp, reed, miscanthus, poplar and willow show the best prospects. These crops are sustainable and may in the future be economically feasible. Ethanol from winter wheat shows the most favourable environmental effects, but is not economically efficient. Liquid fuels from oil seed rape and sugar beet are not very sustainable. 2 tabs., 4 refs.
1994-12-06
Deploying anaerobic digesters: Current status and future possibilities
Energy Technology Data Exchange (ETDEWEB)
Unmanaged pollutants from putrescible farm, industrial, and municipal wastes degrade in the environment, and methane emitted from their decomposition may contribute to global climate change. Under modern environmental regulations, these wastes are becoming difficult to dispose of using traditional means. One waste management system, anaerobic digestion or AD, not only provides pollution prevention but can also convert a disposal problem into a new profit center. This report is drawn from a special session of the Second Biomass Conference of the Americas. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.
1996-01-01
Computer Simulation of Factors Affecting Rural Education.
Computer simulations of agricultural finance and management may be helpful to students preparing for agricultural careers. Simulations would provide problem definition and problem solving in realistic interactions with complex and ambiguous situations similar to those encountered in farming. The paper describes a major financial problem for farmers, explores the implications of that problem for students, and outlines a computer-based simulation model which would give students experience in dealing with the problem. Data sources for simulations, potentials of interactive exercises among students, and advantages of using real data with existing ambiguities are described. The board game "AGRICULTURE" is discussed as a prototype for simulation. (LFL)
1986-02-01
A perspective of the Malaysian highway energy consumption and future power supply
British Library Electronic Table of Contents (United Kingdom)
In this short communication, we discuss the energy consumption trends in the Malaysian road transport sector, with a special emphasis on the energy losses due to vehicle aerodynamic drag on highways. The recent trends of energy consumption in the Malaysian road transport sector are reviewed. It is evidently shown that the aerodynamic losses represented exceed 1.2MTOE annually since 2002. A novel concept of vertical-axis wind turbine (VAWT) farms for harvesting aerodynamic energy losses on Malaysian highways is preliminarily proposed. The novel concept aims at providing a sustainable and green energy source for the lighting of the highway network in the country.
2011-01-01
A PDA-Based ECG Beat Detector for Home Cardiac Care.
Recent rapid growth in mobile computing technologies enables telemedicine applications to operate on mobile devices. Our focus is on the design of an integrated electrocardiogram (ECG) beat detector on a Personal Digital Assistant (PDA) platform for the health screening process. The ECG beat detector module will be supported by the PDA version of Personal Health Information Management System (PHIMS) and Facilitated Accurate Referral Management System (FARMS) through wireless network infrastructure as a home-based mobile cardiac monitoring solution. PMID:17282192
2005-01-01
Renovation of air-conditioning at La Defense; Renovation de la climatisation a La Defense
Energy Technology Data Exchange (ETDEWEB)
Twenty years after its building, the tertiary sector of La Defense district near Paris has been rehabilitated. The main reason is not only the age and wear of materials but the heating costs, the fire protection regulations, the search for a better air quality and air renewing with less dusts, smells and noise and a controlled moisture. This paper describes first the original installation of the Monge CB 6 office building and then the renovated installation: the central hot and cold air-treatment plant, the variable flow ventilation system, the air extraction and supply system threw the roofs and the pressure and thermal regulation of the installation. (J.S.)
1997-05-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.
1998-12-31
Passive dosimetry of radon and its daughters using solid state nuclear track detectors (SSNTDs)
Energy Technology Data Exchange (ETDEWEB)
Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).
1993-01-01
International Nuclear Information System (INIS)
This bibliography contains citations concerning the control and mitigation of radon pollution in homes and commercial buildings. Citations cover radon transport studies in buildings and soils, remedial action proposals on contaminated buildings, soil venting, building ventilation, sealants, filtration systems, water degassing, reduction of radon sources in building materials, and evaluation of existing radon mitigation programs including their cost effectiveness. Analysis and detection of radon and radon toxicity are covered in separate published bibliographies. (Contains 129 citations fully indexed and including a title list.).
Heating-cooling ceilings and cold beams; Plafonds chauffants-rafraichissants et poutres froides
Energy Technology Data Exchange (ETDEWEB)
The aim of this document is to make a state-of-the-art of the techniques of heating-cooling ceilings and cold beams. These systems offer many advantages: they generate a high quality thermal comfort, they are energy efficient, and offer important room saving, particularly interesting in the case of building renovation. The document comprises 5 parts dealing with: 1 - the heating-cooling ceilings; 2 - the cold beams; 3 - the elements necessary for the dimensioning (building-system interactions, ventilation, temperature regulation and safety systems); 4 - dimensioning method; 5 - design, realization and operation: the rules to follow. (J.S.)
2004-07-01
Energy Technology Data Exchange (ETDEWEB)
This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.
2007-05-01
Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions
Energy Technology Data Exchange (ETDEWEB)
This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.
2007-02-01
Anesthetic considerations for nontransplant procedures in lung transplant patients
British Library Electronic Table of Contents (United Kingdom)
Lung transplantation has become an accepted option for many patients with end-stage pulmonary diseases. Anesthesia and surgery following lung transplantation may be required for various diseases that may affect both systemic organs and the transplanted graft. When a patient with a lung transplant undergoes surgery, there is the potential for interference with lung function, depending on the type of intervention and its anatomical site. Accurate preoperative evaluation, an understanding of the physiology of the transplanted lung, proper airway instrumentation, individualized management of intraoperative ventilation, and fluid balance are essential for a positive perioperative outcome.
2011-01-01
A study on the reduction of indoor radon contamination
Energy Technology Data Exchange (ETDEWEB)
The purpose of the present study is to find ways to reduce the quantity of indoor radon contamination. The study was done from July, 2005 until December, 2005. It was found out that the easiest and most effective way to do that is to open the windows as often as possible and let the indoor air flow outside. When it is not possible to ventilate a room, the indoor radon contamination quantity can reduced by providing activated charcoal in the room. It has been proved that activated charcoal can absorb the room in the air. We need more activated charcoal in proportion to the size of the room. A further research is needed to investigate the amount of activated charcoal that will work most effectively.
2006-06-15
Energy Technology Data Exchange (ETDEWEB)
The school building complex Waterland in The Hague, Netherlands, was built with a hybrid ventilation system. The indoor environment and energy consumption were monitored for one year. Air quality and thermal comfort are of a high quality and the consumption of energy for heating is circa 35% lower than normal. The Waterland project was one of eight demonstration projects, carried out within the framework of the ECBS-Annex 35: Hybrid ventilation in New and retrofitted Office Buildings. ECBS stands for the IEA-program Energy Conservation in Buildings and Community Systems. [Dutch] In ECBCs-annex 35 (ECBS staat voor het IEA-programma Energy Conservation in Buildings and Community Systems) is uitgebreid onderzoek gedaan naar hybride ventilatiesystemen in kantoren en scholen. Dit project heeft geleid tot acht internationale voorbeeldprojecten, waarvan scholencomplex Waterland te Den Haag er een van is. Het scholencomplex is in 2003 opgeleverd met ...
2005-11-01
Energy Technology Data Exchange (ETDEWEB)
The gotten concentrations of radon-222 in the installations of the IEN had been determined using the active and passive methods. The active method consisted on the use of the alpha spectrometry with a portable equipment Tracerlab Instruments WLM- Plus. In the determination for the passive method, one used detectors of nuclear strokes of type LEXAN. The raised values had been gotten in the wastes deposit and its annexes, room of the press and laboratory of wastes handling. It was observed, in this sector, an instantaneous measure of alpha spectrometry, concentrations around 1000 Bq.m-3, which had over all to the function of storage, the sector, a great volume of natural radioactive materials, especially of radium-226. This determination was carried through in an extreme situation of ventilation zero, where the gates had been kept closed during the execution of the same one. It was observed, however, a considerable fall, with values ten times inferior, after to ...
2000-07-01
An experimental study of the ventilation performance of cold-air distribution systems
Energy Technology Data Exchange (ETDEWEB)
The ventilation performance of cold-air distribution systems was investigated in a full-scale test room for three different designs of ceiling-mounted diffusers: a large square radial, a small square radial, and two linear diffusers. The supply air temperature was 38 F (3.3 C). Tests were conducted with internal heat loads and with and without furnishings. The local mean ages of air, air diffusion effectiveness, and contaminant-removal efficiency were measured using tracer gas techniques to assess the performance of the ventilation system in maintaining adequate air quality conditions in the occupied region. Air velocities and temperatures were also measured in the occupied region to calculate the air diffusion performance index (ADPI). It was found that the cold-air distribution system provided satisfactory air quality and thermal comfort conditions to the occupied region of the room. It was also found that internal furnishings (partitions, ...
1994-12-31
A desiccant dehumidifier for electric vehicle heating
Energy Technology Data Exchange (ETDEWEB)
Vehicle heating requires a substantial amount of energy. Engines in conventional cars produce enough waste heat to provide comfort heating and defogging/defrosting, even under very extreme conditions. Electric vehicles (EVs), however, generate little waste heat. Using battery energy for heating may consume a substantial fraction of the energy storage capacity, reducing the vehicle range, which is one of the most important parameters in determining EV acceptability. Water vapor generated by the vehicle passengers is in large part responsible for the high heating loads existing in vehicles. In cold climates, the generation of water vapor inside the car may result in water condensation on the windows, diminishing visibility. Two strategies are commonly used to avoid condensation on windows: windows are kept warm, and a large amount of ambient air is introduced in the vehicle. Either strategy results in a substantial heating load. These strategies are often used in combination, and a ...
1996-09-01
Summary of Initial Testing of SuperLig 644 at the TFL Ion Exchange Facility
Energy Technology Data Exchange (ETDEWEB)
Research at the Savannah River Technology Center aided development of a technical design basis for a Waste Treatment Plant (WTP) to pre-treat and vitrify Hanford tank waste as part of the River Protection Project (RPP). The research addresses safety concerns, process optimization, and waste form compliance. This program will provide technical data to ensure that the process functions as it was designed and minimizes costs.
2001-04-17
Recent process developments at the SOMAIRE uranium mill
International Nuclear Information System (INIS)
This paper reviews the mill flowsheet applied at the SOMAIR (Societe des Mines de l'Air) uranium mill in Niger. It focuses on the yellow cake quality improvements achieved by molybdenum and zirconium elimination through double yellow cake precipitation in tanks at first stage and through size/density control in a fluidized bed precipitator at second stage. Water saving aspects in the plant are also presented. (author)
2000-09-09
Project quality assurance plant: Sodium storage facility, project F-031
International Nuclear Information System (INIS)
The Sodium Storage Facility Project Quality Assurance Plan delineates the quality assurance requirements for construction of a new facility, modifications to the sodium storage tanks, and tie-ins to the FFTF Plant. This plan provides direction for the types of verifications necessary to satisfy the functional requirements within the project scope and applicable regulatory requirements determined in the Project Functional Design Criteria (FDC), WHC-SD-FF-FDC-009.
Energy Technology Data Exchange (ETDEWEB)
This Test Plan outlines the testing to be done on the Special Protective Coating (SPC) Polyurea which includes: Tank Waste Compatibility, Decontamination Factor Testing, and Adhesion Strength Testing after a sample has been exposed to Radiation.
2001-01-15
Melter Disposal Strategic Planning Document
Energy Technology Data Exchange (ETDEWEB)
This document describes the proposed strategy for disposal of spent and failed melters from the tank waste treatment plant to be built by the Office of River Protection at the Hanford site in Washington. It describes program management activities, disposal and transportation systems, leachate management, permitting, and safety authorization basis approvals needed to execute the strategy.
2000-09-25
Energy Technology Data Exchange (ETDEWEB)
Vermicomposts as a biofertilizer can be a great option for pond manuring as they never cause any long term harm to the soil like chemical fertilizer. In this study vegetable and horticulture waste was used as an important media for vermiculture. Three separate cemented tanks (6 m{sup 3} each) were used in the system as control tank, vermicompost fertilized tank and inorganic fertilizer manured tank. Monoculture of fish was carried out with cat fish, Clarias batrachus. The produced earthworms were used as fish feed. Regular monitoring of water parameter was conducted in three different ponds. Specifically, the algal biomass variation was quite helpful in analysing the behavior of the ponds. NPK value of soil samples was analyzed intermittently to know the eutrophication level. Despite the hot summer temperature in northern part of India, which is not ideal for fish growth, we have recorded an encouraging ...
2004-05-01
Information systems definition architecture
Energy Technology Data Exchange (ETDEWEB)
The Tank Waste Remediation System (TWRS) Information Systems Definition architecture evaluated information Management (IM) processes in several key organizations. The intent of the study is to identify improvements in TWRS IM processes that will enable better support to the TWRS mission, and accommodate changes in TWRS business environment. The ultimate goals of the study are to reduce IM costs, Manage the configuration of TWRS IM elements, and improve IM-related process performance.
1996-06-20
High level waste storage tanks 242-A evaporator S/RID phase II assessment report
Energy Technology Data Exchange (ETDEWEB)
This document, the Standards/Requirements Identification Document (S/RID) Phase 2 Assessment Report for the subject facility, represents the results of a Performance Assessment to determine whether procedures containing S/RID requirements are fully implemented by field personnel in the field. It contains a summary report and three attachments; an assessment schedule, performance objectives, and assessments for selected functional areas.
1996-09-27
International Nuclear Information System (INIS)
A fluidic pump comprises a two-diode pump having a first displacement vessel, a third diode connected to receive output from the two-diode pump through a delivery line and discharge to an outlet, and a second displacement vessel connected to the delivery line. There is a feed tank at a greater height than the two-diode pump, and a drive unit for alternately pressurising and venting the first and second displacement vessels. The drive pressure required to operate the pump can be of the order of half that for a single stage 2-diode pump. (author).
1988-05-19
Experimental verification of caustic-side solvent extraction for removal of cesium from tank waste.
Energy Technology Data Exchange (ETDEWEB)
The objectives of this report are: to demonstrate complete CSSX process flowsheet (proof of concept)--decontamination factor {ge} 40,000, and concentration factor {approx}15; Scientific and technical issues evaluated--stage efficiency, temperature control, hydraulic performance, long time (multi-day) operation, short-term shutdown, effect of solids, and recovery from Cs moving through strip section.
2001-09-21
Determination of reactor kinetic parameters in a two-core reactor
Energy Technology Data Exchange (ETDEWEB)
The kinetic parameters, ..cap alpha.. the coupling coefficient and tau-bar the mean neutron transit time have been determined using a reactor oscillator on the coupled-core of the Queen Mary College research reactor. By using correlation techniques it has proved possible to use detectors small enough to be inserted in the fuel tanks. It is shown that the simplified Baldwin model with one-group diffusion theory is inadequate to describe the kinetic behaviour and the experimentally-determined parameters are dependent upon the positioning of the detectors.
1982-01-01
B Plant treatment, storage, and disposal (TSD) units inspection plan
Energy Technology Data Exchange (ETDEWEB)
This inspection plan is written to meet the requirements of WAC 173-303 for operations of a TSD facility. Owners/operators of TSD facilities are required to inspection their facility and active waste management units to prevent and/or detect malfunctions, discharges and other conditions potentially hazardous to human health and the environment. A written plan detailing these inspection efforts must be maintained at the facility in accordance with Washington Administrative Code (WAC), Chapter 173-303, ``Dangerous Waste Regulations`` (WAC 173-303), a written inspection plan is required for the operation of a treatment, storage and disposal (TSD) facility and individual TSD units. B Plant is a permitted TSD facility currently operating under interim status with an approved Part A Permit. Various operational systems and locations within or under the control of B Plant have been permitted for waste management activities. Included are the following TSD units: Cell 4 Container Storage Area; B ...
1996-04-26
An approach to software quality assurance for robotic inspection systems
International Nuclear Information System (INIS)
Software quality assurance (SQA) for robotic systems used in nuclear waste applications is vital to ensure that the systems operate safely and reliably and pose a minimum risk to humans and the environment. This paper describes the SQA approach for the control and data acquisition system for a robotic system being developed for remote surveillance and inspection of underground storage tanks (UST) at the Hanford Site.
1993-11-14
International Nuclear Information System (INIS)
In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows characterized by natural circulation, high Rayleigh numbers and low Reynolds numbers; validity of heat transfer ...
National Ignition Facility Incorporates P2/E2 in Aqueous Parts Cleaning of Optics Hardware
Energy Technology Data Exchange (ETDEWEB)
When completed, Lawrence Livermore National Laboratory's (LLNL) National Ignition Facility (NIF) will be the world's largest laser with experimental capabilities applicable to stockpile stewardship, energy research, science and astrophysics. As construction of the conventional facilities nears completion, operations supporting the installation of specialized laser equipment have come online. Playing a critical role in the precision cleaning of mechanical parts from the NIF beamline are three pieces of aqueous cleaning equipment. Housed in the Optics Assembly Building (OAB), adjacent to NIF's laser bay, are the large mechanical parts gross cleaner (LMPGC), the large mechanical parts precision cleaner (LMPPC), and the small mechanical parts gross and precision cleaner (SMPGPC). These aqueous units, designed and built by Sonic Systems, Inc., of Newtown, Pennsylvania, not only accommodate parts that vary greatly in size, weight, geometry, surface finish and ...
2001-07-27
British Library Electronic Table of Contents (United Kingdom)
Malformations in farmed fish are a prime research topic as it has a major impact on fish welfare and on the economical value of the product. In this study, the genetic component of spine deformities was estimated in European sea bass, a major species of Mediterranean aquaculture, with the use of a posteriori reconstruction of pedigree with microsatellites. Our population exhibited a very high malformation rate (81%), probably due to intense swimming of fish during pre-growing. The heritability of global spine deformities was evaluated to be 0.21?0.04 on the underlying scale (0.33?0.06 for lordosis, 0.13?0.04 for scoliosis). Deformities scored by an internal or external examination turned out to be genetically the same trait (genetic correlations>0.9), although phenotypic correlations were ...
2009-01-01
Using "EC-Assess" to Assess a Small Biofuels Project in Honduras
Biofuels may contribute to both rural economic development and climate change mitigation and adaptation. The Gota Verde Project in Yoro, Honduras, attempts to demonstrate the technical and economic feasibility of small-scale biofuel production for local use by implementing a distinctive approach to feedstock production that encourages small farm sizes, mixed cropping of biofuel feedstock from Jatropha and food crops, particularly corn and beans, grown side by side on the same farmland and the total involvement of small rural farmers. But is the project sustainable? Using EC-Assess, the Earth Charter ethics-based assessment tool, to assess the sustainability of this project, the author found that in some assessment categories the actions surpassed the intended objectives, showing that the project was achieving certain Earth Charter goals without specifically stating its intention to address them. (Contains 3 images, 3 figures and 2 notes.)
2010-09-01
Energy Technology Data Exchange (ETDEWEB)
Two days of hearings on Titles V and X of the Water Resources Development Act of 1983 brought comments from representatives of several states, farm and transport industries, environmental groups, and concerned taxpayers. Title V requires the collection of new funds from users beyond a ceiling set for annual spending on water projects, while Title X proposes a cost-sharing partnership for certain navigation projects. Witnesses were requested to confine their comments to constructive alternatives to the proposed legislation. Additional material on the deep river study and statements submitted for the record follow the testimony of 28 witnesses.
1984-01-01
State of the art report on bituminized waste forms of radioactive wastes
International Nuclear Information System (INIS)
In this report, research and development results on the bituminization of radioactive wastes are closely reviewed, especially those regarding waste treatment technologies, waste solidifying procedures and the characteristics of asphalt and solidified forms. A new concept of the bituminization method is suggested in this report which can improve the characteristics of solidified forms. Stable solid forms with high leach resistance, high thermal resistance and good compression strength were produced by the suggested bituminization method, in which spent polyethylene from agricultural farms was added. This report can help further research and development of improved bituminized forms of radioactive wastes that will maintain long term stabilities in disposal sites. (author). 59 refs., 19 tabs., 18 figs
1997-06-08
Persistent halogenated compounds in two typical marine aquaculture zones of South China
British Library Electronic Table of Contents (United Kingdom)
Samples of two seawater farmed fish (crimson snapper (Lutjanus erythopterus) and snubnose pompano (Trachinotus blochii)), water, air, sediment, fish feed, macroalgae and phytoplankton were collected from two estuarine bays (Daya Bay and Hailing Bay) in South China. The concentrations of persistent halogenated compounds (PHCs) including polybrominated diphenyl ethers (PBDEs), organochlorine pesticides and polychlorinated biphenyls (PCBs) varied widely with the different sample matrices under investigation. The compositional patterns in fish, fish feed, macroalgae and phytoplankton, as well as the good correlations between the abundances of p,pprime-DDT and BDE-209 and their metabolites (i.e., p,pprime-DDD and p,pprime-DDE for p,pprime-DDT and BDE-47 for BDE-209) in fish indicated the occurr...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
The study investigates the possibility of enhancing crop water productivity in the parts of Northwest India where groundwater quality is marginal and canal water supply is severely scarce. Soil, Water, Atmosphere and Plant (SWAP) model was calibrated and validated in three farmers' fields with varying canal water availability and groundwater quality in the Kaithal Irrigation Circle of the Bhakra Canal system, Haryana. On the basis of predicted and observed soil water content, pressure heads, salt concentration at 2 week intervals and crop yields, the model was found suitable for use in the region. A few nomographs were prepared to provide a graphical method to predict the effect of different combinations of water quality and depth of water application on crop yield and soil salinity and to...
2008-01-01
Isolation and molecular identification of small ruminant mycoplasmas in Jordan
British Library Electronic Table of Contents (United Kingdom)
Mycoplasma infections of small ruminants are known to exist in the Mediterranean region, Asia, Africa and cause significant economic impacts but little is known of the Mycoplasma spp. in sheep and goats in the Middle East. During the period of 2002-2003, 104 flocks of local sheep and goats (17 sheep, 27 goat and 60 mixed flocks) were surveyed for the occurrence of mycoplasma infections in Northern Jordan. The clinical signs seen in the studied flocks were, to varying degrees, mastitis in sheep and goats, arthritis, mainly in kids, and pneumonia in both sheep and goats of most age groups. Small ruminant farms were sampled and pooled milk samples and nasal swabs were collected for culture and isolation of mycoplasma. Mycoplasmas were isolated from 17 (26%) of the 62 milk samples and 12 (3.9%...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
An investigation of current dual-fuel natural gas/diesel engine design, performance, and emissions was conducted. The most pressing technological problems associated with dual-fuel engine use were identified along with potential solutions. It was concluded that dual-fuel engines can achieve low NOx and particulate emissions while retaining fuel-efficiency and BMEP levels comparable to those of diesel engines. The investigation also examined the potential economic impact of dual-fuel engines in diesel-electric locomotives, marine vessels, farm equipment, construction, mining, and industrial equipment, and stand-alone electricity generation systems. Recommendations for further additional funding to support research, development, and demonstration in these applications were then presented.
1994-11-01
Development of a solar thermal storage system suitable for the farmhouse heating in northeast China
Energy Technology Data Exchange (ETDEWEB)
This study reported on the performance of a passive solar radiant floor heating system designed for standard energy-saving farmhouses in northeast China. Weather data in the region was analyzed in terms of solar radiation, temperature, humidity and light levels. The heating characteristics of the building materials such as windows, doors, walls and roofs were also analyzed along with the indoor thermal environment of the farmhouse. The heating load was then calculated along with the size of the thermal storage element and the area of the collector element. The passive solar radiant floor heating system was designed for heating during the winter and cooling in summer. According to the results, the heating characteristics of the system have the potential to improve farming villages environment and the use of renewable energy.
2010-07-01
British Library Electronic Table of Contents (United Kingdom)
Phreatic groundwater pumping is affecting water availability for crops in areas with a shallow water table. This can reduce crop growth and so affect farm income. There is a need for a generic and transparent method to assess the agricultural damage caused by water table drawdown. This paper proposes such a method that consists of 'damage tables' relating agricultural production losses to the groundwater regime for different soil/crop combinations found in Northern Belgium. The damage tables are constructed based on numerous simulations with the agrohydrological model SWAP, in which the bottom boundary conditions are gradually changed to reflect different groundwater regimes. The credibility of the resulting metamodel is assessed in three ways: using (1) field data, (2) an existing local e...
2010-01-01
Environmental Research Database
ObjectivesThe vision The Centre's vision is a rural transformation in the developing world where smallholder households massively increase their use of trees in agricultural landscapes to improve their food security, nutrition, income, health, shelter, energy resources and environmental sustainability. This vision is founded upon three basic tenets: 1. The growing importance of trees and treebased systems in sustaining livelihoods and agroecosystems; 2. The Centre's experience and comparative adv [continued...]DescriptionBackground: The International Council for Research in Agroforestry (ICRAF) was created in response to a visionary study in the mid-1970s led by forester John Bene of Canada's International Development Research Centre (IDRC). The study coined the term 'agroforestry' and called for global recognition of the key role trees play on farms. This led to the establishment of ICRAF in 1978 to promote agroforestry research in developing countries. Intended ...
2016-01-31
Computing in high energy physics
Energy Technology Data Exchange (ETDEWEB)
This book deals with advanced computing applications in physics, and in particular in high energy physics environments. The main subjects covered are networking; vector and parallel processing; and embedded systems. Also examined are topics such as operating systems, future computer architectures and commercial computer products. The book presents solutions that are foreseen as coping, in the future, with computing problems in experimental and theoretical High Energy Physics. In the experimental environment the large amounts of data to be processed offer special problems on-line as well as off-line. For on-line data reduction, embedded special purpose computers, which are often used for trigger applications are applied. For off-line processing, parallel computers such as emulator farms and the cosmic cube may be employed. The analysis of these topics is therefore a main feature of this volume.
1986-01-01
Changes in Soil Properties and Vegetable Growth in Preparation for Organic Farming in Hawaii
British Library Electronic Table of Contents (United Kingdom)
Changes in soil properties and vegetable growth were quantified on a low-fertility tropical soil. Four treatments (two composts, urea, and control) were applied to an Oxisol (Rhodic Haplustox, Wahiawa series) in a field on Oahu, Hawaii. Chinese cabbage (Brassica rapa, Chinensis group) and eggplant (Solanum melongena) were grown sequentially as test crops. Soil quality as measured by hot-water-soluble carbon, dehydrogenase activity, and cation exchange capacity (CEC) increased by compost amendments. Total organic carbon or carbon dioxide (CO2) respiration rate did not correlate with the soil amendments. Nitrogen (N) nutrition was the main factor that improved growth and carotenoid content in cabbage. The urea treatment promoted better growth in cabbage, whereas good-quality compost, made of...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Climate change is one of the main global issues of modern time. Ever increasing demand for food/feed and the need for higher environmental standards require shaping of the agricultural activities toward ecological and more sustainable efficient systems. One of the principal ways of attaining higher productivity and environmental standards is identification and adoption of beneficial management practices (BMP) by reviewing the conventional agricultural activities. The BMP are agricultural practices that promote sustainable land stewardship and maintain/increase profitability of farms. The BMP are from both crop and animal production systems and tradeoffs between the two systems could provide several opportunities in reducing, removing and/or avoiding of greenhouse gases (GHG) emissions. Des...
2011-01-01
Balancing Energy, Food, Natural Resources and Environment in Nepal
Energy Technology Data Exchange (ETDEWEB)
Nepal could harness less than 1% of its 83000 MW hydropower potential. Pancheshwar Multipurpose Project (6720 MW) is a bi-national project on Mahakali River bordering between Nepal and India. The earnings from: electricity (NRs. 34.55 billion/year); irrigation (NRs. 5.55 billion/year), fish farming (NRs. 8.65 billion/year), carbon trading (NRs. 4.42 billion/year) and many billions from other sources e.g. eco-tourism, industry, horticulture, herbiculture, floriculture, sericulture, rafting and water sports, educational and vocational training and other industrial/commercial activities can catapult the socioeconomic horizon of Nepal. Hence, PMP should be jointly developed in the earliest and build confidence for the further hydropower development.
2010-09-15
A Reduced Wind Power Grid Model for Research and Education
Energy Technology Data Exchange (ETDEWEB)
A reduced grid model of a transmission system with a number of central power plants, consumption centers, local wind turbines and a large offshore wind farm is developed and implemented in the simulation tool PowerFactory (DIgSILENT). The reduced grid model is given by Energinet.dk, Transmission System Operator of Denmark (TSO) for Natural Gas and Electricity, to the Danish Universities and the Risoe National Laboratory. Its intended usage is education and studying of interaction between electricity-producing wind turbines and a realistic transmission system. Focus in these studies is on voltage stability issues and on the ride-through capability of different wind turbine concepts, equipped with advanced controllers, developed by the Risoe National Laboratory.
2006-07-01
This book describes one approach to building and operating biogas systems. The biogas systems include raw material preparation, digesters, separate gas storage tanks, use of the gas to run engines, and the use of the sludge as fertilizer. Chapters included are: (1) "Introduction"; (2) "Biogas Systems are Small Factories"; (3) "The Raw Materials of Biogas Digestion"; (4) "The Daily Operation of a Biogas Factory"; (5) "The Once a Year Cleaning of the Digester"; (6) "Tanks and Pipes: Storing and Moving Biogas"; (7) "The Factory's Products: Biogas"; (8) "The Factory's Products: Biofertilizer"; (9) "The ABCs of Safety"; and (10) "Conclusion: Profiting from an Appropriate Technology." Many diagrams are provided throughout this handbook. New ideas, composting, bioinsecticides, ferrocement, facts and figures, sources and resources, feasibility studies, problem solving, and vocabulary are presented in the appendices. (YP)
1985-07-01
Subcritical measurements using the /sup 252/Cf source-driven neutron noise analysis method
Energy Technology Data Exchange (ETDEWEB)
This paper describes recent measurements of the subcritical neutron multiplication factor using the /sup 252/Cf source-driven neutron noise analysis method. This work was supported by a program of collaboration between the United States Department of Energy and the Power Reactor and Nuclear Fuel Development Corporation of Japan related to the development of fast breeder technology. The experiment reported consists of a configuration of two interacting tanks of uranyl nitrate aqueous solution with different uranium concentrations in each tank. The /sup 252/Cf-source-driven neutron noise analysis method obtains the subcriticality from the signals of three detectors: the first, a parallel plate ionization chamber with /sup 252/Cf electroplated on one of its plates that is located in or near the system containing the fissile material, and produces an electrical pulse for every spontaneous fission that occurs and thereby serves as a timed source of ...
1985-01-01
Energy Technology Data Exchange (ETDEWEB)
An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 to 2.58% in the increase in the operating cost compared with the latter. A case where the operating cost of the resolving method was sometimes larger than the proposed ...
1996-02-01
Start-up control system and vessel for LMFBR
Energy Technology Data Exchange (ETDEWEB)
A reflux condensing start-up system includes a steam generator, a start-up vessel connected parallel to the steam generator, a main steam line connecting steam outlets of the steam generator and start-up vessel to a steam turbine, a condenser connected to an outlet of the turbine and a feedwater return line connected between the condenser and inlets of the steam generator and start-up vessel. The start-up vessel has one or more heaters at the bottom thereof for heating feedwater which is supplied over a start-up line to the start-up vessel. Steam is thus generated to pressurize the steam generator before the steam generator is supplied with a heat transfer medium, for example liquid sodium, in the case of a liquid metal fast breeder reactor. The start-up vessel includes upper and lower bulbs with a smaller diameter mid-section to act as water and steam reservoirs. The start-up vessel can thus be used not only in a start-up operation but as a mixing tank, a water ...
1987-01-01
Replacement of fishmeal in cobia (Rachycentron canadum) diets using poultry by-product meal
British Library Electronic Table of Contents (United Kingdom)
An 8-week feeding trial was conducted to evaluate the use of local poultry by-product meal (PBM) in replacement of imported fishmeal in the diets of cobia, Rachycentron canadum. Six isolipidic (12%) and isoproteic (45%) experimental diets were formulated using PBM to replace fishmeal at 20, 40, 60, 80 and 100% dietary protein. Eleven juvenile cobia (initial mean weight of 30.7???0.78?g) were randomly stocked in 300-L circular fibreglass tanks and hand-fed based on the total biomass of each tank, twice a day at 0900?h and 1500?h. The fish were group weighed at 2-week intervals to monitor their growth performance in order to adjust the feeding ratio. At the end of the feeding trial, weight gains (WGs) ranging from 221 to 322% were obtained. The specific growth rate (SGR), WG and protein effi...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion potential was estimated to be nearly 100mV vs. SCE. The following measures against pitting corrosion were considered to be effective: (1) Removal of the particles, (2) Corrosion proofing of ...
1998-11-15
Multiple Ion Exchange Column Tests for Technetium Removal from Hanford Tank Waste Supernate
Five cycles of loading, elution, and regeneration were performed to remove technetium from a Hanford waste sample retrieved from Tank 241-AW-101 using SuperLig 639 resin. The waste sample was diluted to 4.95 M Na plus and then was processed to remove 137Cs through dual ion exchange columns each containing 15 mL of SuperLig 644. To remove 99Tc, the cesium decontaminated solution was processed downwards through two ion exchange columns, each containing 12 mL of SuperLig 639 resin. The columns, designated as lead and lag, each had an inside diameter of 1.45 cm and a height of 30 cm. The columns were loaded in series, but were eluted and then regenerated separately. The average technetium loading for the cycles was 250 BV at 10 percent breakthrough. There was no significant difference in the loading performances among the five cycles. The percent removal of 99Tc was greater than 99.94 percent and the average decontamination factor (DF) was approximately 1.7 x 103. ...
2004-02-27
Methods and findings of the SNR study
International Nuclear Information System (INIS)
A featfinding committee of the German Federal Parliament in July 1980 recommended to perform a ''risk-oriented study'' of the SNR-300, the German 300 MW fast breeder prototype reactor being under construction in Kalkar. The main aim of this study was to allow a comparative safety evaluation between the SNR-300 and a modern PWR, thus to prepare a basis for a political decision on the SNR-300. Methods and main results of the study are presented in this paper. In the first step of the risk analysis six groups of accidents have been identified which may initiate core destruction. These groups comprise all conceivable courses, potentially leading to core destruction. By reliability analyses, expected frequency of each group has been calculated. In the accident analysis potential failure modes of the reactor tank have been investigated. Core destruction may be accompanied by the release of significant amounts of mechanical energy. The primary coolant system of SNR-300 is ...
Evaluation of scaling correlations for mobilization of double-shell tank waste
Energy Technology Data Exchange (ETDEWEB)
In this report, we have examined some of the fundamental mechanisms expected to be at work during mobilization of the waste within the double-shell tanks at Hanford. The motivation stems from the idea that in order to properly apply correlations derived from scaled tests, one would have to ensure that appropriate scaling laws are utilized. Further, in the process of delineating the controlling mechanisms during mobilization, the currently used computational codes are being validated and strengthened based on these findings. Experiments were performed at 1/50-scale, different from what had been performed in the previous fiscal years (i.e., 1/12- and 1/25-scale). It was anticipated that if the current empirical correlations are to work, they should be scale invariant. The current results showed that linear scaling between the 1/25-scale and 1/50-scale correlations do not work well. Several mechanisms were examined in the scaled tests which might have contributed to ...
1997-09-01
Design of APhF-IH Linac for a Compact Medical Accelerator
The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a constant voltage distribution along the ...
2003-01-01
International Nuclear Information System (INIS)
The design boron concentration of the Boron Injection Tank (BIT) in Daya Bay Nuclear Power Station is 21000 #mu#g/g. The BIT should operate under high temperature to avoid boron crystallization, causing higher evaporation, frequent water makeup, higher deposition and pipe blockage to decrease the operability of the safety injection system. The author proposes to decrease the boron concentration in BIT from 21000 #mu#g/g to 7000 #mu#g/g to solve the existing problem. The safety analyses (core DNBR and containment response) are conducted and other impacts are evaluated for the BIT reduction. The analysis results show that the core DNBR meets the safety criterion and the containment pressure is within the design value for the steam line rupture accident after the BIT reduction. The feasibility study report of Daya bay BIT reduction has been approved by NNSA. The site implementation of BIT reduction has been finished successfully
1999-12-01
Energy Technology Data Exchange (ETDEWEB)
This project was conducted to evaluate novel approaches for removing radioactive strontium (Sr) and cesium (Cs) from the tank wastes. The bulk of the Sr removal research conducted as part of this project investigated adsorption of Sr onto a novel adsorbent known as iron-oxide-coated sand. The second major focus of the work was on the removal of cesium. Since the chemistries of strontium and cesium have little commonality, different materials (namely, cesium scavengers known as hexacyanoferrates, HCFs) were employed in these tests. This study bridged several scientific areas and yielded valuable knowledge for implementing new technological processes. The applicability of the results extends beyond the highly specialized application niches investigated experimentally to other issues of potential interest for EMSP programs (e.g., separation of chromium from a variety of wastes using IOCS, separation of Cs from neutral and acidic wastes with EC-controlled HCFs).
1999-10-01
Willingness to pay for energy-saving measures in residential buildings
Energy Technology Data Exchange (ETDEWEB)
This paper uses a choice experiment to evaluate the consumers' willingness to pay for energy-saving measures in Switzerland's residential buildings. These measures include air renewal (ventilation) systems and insulation of windows and facades. Two groups of respondents consisting respectively of 163 apartment tenants and 142 house owners were asked to choose between their housing status quo and each one of the several hypothetical situations with different attributes and prices. The estimation method is based on a fixed-effects logit model. The results suggest that the benefits of the energy-saving attributes are significantly valued by the consumers. These benefits include both individual energy savings and environmental benefits as well as comfort benefits namely, thermal comfort, air quality and noise protection. (author)
2008-03-15
The thermal response of an infinite line of open loop wells for ground coupled heat pump systems
British Library Electronic Table of Contents (United Kingdom)
Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial applications...
2011-01-01
Sound climate installations. Gezonde klimaatinstallaties
Energy Technology Data Exchange (ETDEWEB)
An uncomfortable thermal climate, draft complaints and a bad airquality are often related to the climate installation. To avoid badfunctioning of the system a number of preconditions has to be fulfilledwith regard to design, planning and execution, adjustments, completion,control, maintenance and management of the installations. First threetypes of health problems in buildings are shortly discussed: buildingrelated illness, sick building syndrome and building or installationrelated complaints. Then some functions of the climate installationsare described: air filtration, filter classes and filter quality, aswell as investment costs for better filters. Next the causes for thecomplaints are dealt with: air conditioning, ventilation, air quality,and temperatures. Subsequently health affecting aspects in relation tothe climate systems are discussed: outdoor air pollution,microorganisms, bacteria (legionella pneumophila), allergies, ionneutralization and performance of ...
1989-10-01
Energy Technology Data Exchange (ETDEWEB)
After cooling ceilings and source ventilation, simple air conditioning systems like thermal activation of concrete cores are gaining general acceptance. Parallel to this, ground source cooling systems are reducing the need for cold generation. Air conditioning systems of this type are favoured by producers of floor heating systems looking for a new market segment. [German] Nach Kuehldecken und Quellueftung gewinnen jetzt einfach aufgebaute Raumklimaanlagen, wie die thermische Betonkernaktivierung, immer mehr Anhaenger. Parallel dazu werden Verfahren zur Erdkaeltenutzung entwickelt, die den Anteil kuenstlich erzeugter Kaelte weiter zurueckdraengen. Forciert wird diese Art der Klimatisierung insbesondere durch die Hersteller von Fussbodenheizungen, fuer die sich hier ein neues Marktsegment eroeffnet. (orig.)
1999-10-01
Seasonal variation measurements of radon levels in caves using SSNTD method
Energy Technology Data Exchange (ETDEWEB)
The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.
2008-08-15
Seasonal variation measurements of radon levels in caves using SSNTD method
International Nuclear Information System (INIS)
The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.
2008-08-01
Respiratory exposure in buildings due to radon progeny
International Nuclear Information System (INIS)
The #alpha# radiation dose to the lungs of people who live in buildings constructed of some granites, low density concretes, and gypsum boards is higher than for residents of most other types of dwellings due to the air-borne progeny of radon. There is evidence that sealing the interior surfaces with epoxy paint, for example, can reduce the #alpha# dose to the lung significantly without a compensating increase in whole-body exposure to the #gamma#-rays from radon progeny. Based on the incidence rates for lung cancer in uranium miners, a concentration of radon of the order of 1 to 5 pCi/l. appears to be a reasonable limit for 'lifetime' exposure indoors for 'typical' home ventilation conditions. (author).
1976-01-01
Radon concentration measurements in bituminous coal mines
Energy Technology Data Exchange (ETDEWEB)
Radon measurements were carried out in Kozlu, Karadon and Uzulmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) in the study area. The radon concentration measurements were performed on a total of 42 points in those three mines. The annual exposure, the annual effective dose and lifetime fatality risk, which are the important parameters for the health of workers, were estimated based on chronic occupational exposure to the radon gas, which is calculated using UNCEAR-2000 and ICRP-65 models. The radon concentrations at several coal production faces are higher than the action level of 1000 Bq m{sup -3}. It is suggested that the ventilation rates should be rearranged to reduce the radon concentration.
2005-07-01
Induction motor for tunnel exhauster; Tunnel haifukiyo yudo dendoki
Energy Technology Data Exchange (ETDEWEB)
A totally-enclosed, fan-cooled, rib-cooled type induction motor is adopted for an exhauster which is to be installed in a ventilation station for dust catcher in a tunnel. It has the highest capacity in Japan for the above purpose, and is provided with a cooling fan inside to recirculate cooled air, thereby improving cooling efficiency and reducing size and weight. Three-row combined angular ball bearings are used as the thrust bearings, and grease lubrication system is adopted to simplify the inspection/maintenance works. It is to be delivered to Japan Highway Public Corporation's Shizuoka Construction Bureau, Yaizu site office. Its electric specifications are 455 kW, 440 V, 890 A and 510 rpm, and its mechanical specifications are thrust load: 16 kN and impeller load: 7.2 kN. (translated by NEDO)
2000-01-10
Improvement of methane drainage in high gassy coal seam using waterjet technique
Energy Technology Data Exchange (ETDEWEB)
Traditional methane drainage methods, including conventional ventilation and boreholes drilled in the coal seam, are widely used in modern coal mining operation in China. However, it is often noted that the gas drainage presents low efficiency in most coal mines due to low permeability of the coal seam, which not only affects the safety, but also the productivity of the coal mine. This paper describes the development and application of the waterjet cutting system, which is used to create artificial fractures and increase the permeability of coal seam for the improvement of methane drainage in underground coal mines in China. According to underground monitoring, a significant improvement of methane drainage efficiency of up to 3 to 6 times over the traditional methods has been achieved. (author)
2009-07-01
High-level waste canister storage final design, installation, and testing. Topical report
Energy Technology Data Exchange (ETDEWEB)
This report is a description of the West Valley Demonstration Project`s radioactive waste storage facility, the Chemical Process Cell (CPC). This facility is currently being used to temporarily store vitrified waste in stainless steel canisters. These canisters are stacked two-high in a seismically designed rack system within the cell. Approximately 300 canisters will be produced during the Project`s vitrification campaign which began in June 1996. Following the completion of waste vitrification and solidification, these canisters will be transferred via rail or truck to a federal repository (when available) for permanent storage. All operations in the CPC are conducted remotely using various handling systems and equipment. Areas adjacent to or surrounding the cell provide capabilities for viewing, ventilation, and equipment/component access.
1998-04-01
Energy Technology Data Exchange (ETDEWEB)
An experimental and theoretical study of heat and mass transfer analogy and a comparison of that to a binary liquid mixture evaporation is presented. Common organic solvents, ethanol and n-heptane, were used to form an alcohol - hydrocarbon mixture. Studies were carried out in a horizontal rectangular channel having air flow velocities of 0.2 - 0.9 m/s. Heat transfer coefficients were measured with a copper plate resistor and mass transfer coefficients with a square pool. The heat and mass transfer analogy is presented for a system having two evaporating compounds with a fixed value of air flow and verified by measuring and comparing mass transfer coefficients for distilled water with air flow velocities of 0.2 - 0.9 m/s. An illustrative example of the use of the theory for industrial ventilation is presented. (author)
1995-12-31
General flow and thermal boundary conditions in indoor air flow simulation
Energy Technology Data Exchange (ETDEWEB)
The concepts of general flow and thermal boundary conditions are introduced to treat the interaction between indoor and outdoor thermal environments in computational fluid dynamics (CFD) simulations. The results from a multi-zone model are used to supply the general flow boundary conditions. The energy balance equation at wall-air interfaces is used to supply the general thermal boundary conditions. An example calculation in a 13-room building shows that infiltration influences indoor air flow patterns considerably. The air flow in a room ventilated by displacement is measured and simulated. Two surface coatings are considered, i.e. black walls and aluminum walls. Implementation of these two boundary conditions is essential in predicting air flow patterns, air quality, and thermal comfort in a real building. (author)
1994-12-31
Dissection of the thoracic aorta - role of CT and MRT following aortic replacement
International Nuclear Information System (INIS)
Dynamic CT and MRT were performed in 21 patients who had undergone prosthetic replacement of the aorta because of dissection of the thoracic aorta. There is no difference between MRI and dynamic CT in the demonstration of a persistent intimal flap, the formation of a thrombus and the assessment of the aortic diameter in patients who underwent surgery for thoraco-abdominal aortic dissection. MRI, however, is superior in the identification of the true and false lumen and the demonstration of the distal anastomotic site. The major advantages of MRI are that there is no need for intravenous contrast agents, that it is high sensitive to flow phenomena, and that it can demonstrate the aortic arch and the ascending aorta on sagittal oblique sections. The major disadvantages of MRI are the limited access to the patient during the procedure, and the inability to examine patients fitted with pacemakers or who are on assisted ventilation. Today, MRI is considered the method ...
British Library Electronic Table of Contents (United Kingdom)
The contents of polycyclic aromatic hydrocarbons (PAH) and phenolic substances in Frankfurter-type sausages were investigated depending on hot smoking conditions (glow smoke). For the 24 smoking experiments (performed in duplicates) three different smoke densities and ventilator velocities as well as wood chips with five different moisture contents were tested. During the smoking process, concentrations of O"2, CO"2 and CO, humidity and temperature in the smoking chamber as well as smoke generation temperature were determined. The chemical analysis included the contents of the 15+1 EU priority PAH and the phenolic substances guaiacol, 4-methylguaiacol, syringol, eugenol and trans-isoeugenol. The smoking conditions had a significant influence on smoke generation temperature, organoleptic pr...
2012-01-01
Energy Technology Data Exchange (ETDEWEB)
Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.
1998-01-01
Air conditioning in high rise buildings; Conditionnement d'air dans les immeubles de grande hauteur
Energy Technology Data Exchange (ETDEWEB)
This two-tomes book brings together the 108 presentations given at the first conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: general design and control systems, including split systems, radiant panels, fluctuating and gravity ventilation etc..; energy consumption, optimization and heat recovery; cold storage for peak shaving, including ice slurry circulation; indoor air quality; fire and smokes protection, protection against chimney effects and lighting spots; use of fuzzy logic and of neural networks. It includes also a description of the high rise building situation and works in progress in China, Japan and in some other countries. (J.S.)
1997-07-01
Wind-To-Hydrogen Project: Operational Experience, Performance Testing, and Systems Integration
Energy Technology Data Exchange (ETDEWEB)
The Wind2H2 system is fully functional and continues to gather performance data. In this report, specifications of the Wind2H2 equipment (electrolyzers, compressor, hydrogen storage tanks, and the hydrogen fueled generator) are summarized. System operational experience and lessons learned are discussed. Valuable operational experience is shared through running, testing, daily operations, and troubleshooting the Wind2H2 system and equipment errors are being logged to help evaluate the reliability of the system.
2009-03-01
Energy Technology Data Exchange (ETDEWEB)
This analysis defines and evaluates the surface water supply system from the existing J-13 well to the North Portal. This system includes the pipe running from J-13 to a proposed Booster Pump Station at the intersection of H Road and the North Portal access road. Contained herein is an analysis of the proposed Booster Pump Station with a brief description of the system that could be installed to the South Portal and the optional shaft. The tanks that supply the water to the North Portal are sized, and the supply system to the North Portal facilities and up to Topopah Spring North Ramp is defined.
1996-02-06
Relining of scrubbers in flue gas desulfurization plants
Rubber lining is used as a corrosion protection material in European flue gas desulfurization plants, for scrubbers, tanks, pipe systems, etc. Although these rubber linings can last more than 15 years, relining still is necessary. The difficulty of shutting down power station units requires that the time scale of this replacement be kept to a minimum. High-pressure water systems have proven successful as an efficient method for removal of the old lining. The working steps and time scale are demonstrated for one such relining case.
1999-09-01
R&D prioritization and resource management for technology selection
Energy Technology Data Exchange (ETDEWEB)
This paper presents a decision approach, and associated computer software tools, for prioritizing and selecting among technology development activities. The approach elicits and then summarizes technology development preferences from stakeholders, and then integrates preferences into a set of funding recommendations. By formalizing the technology review process, the decision approach builds consensus and clarifies the basis for final budget decisions. The software development was conducted jointly by Pacific Northwest Laboratory and Decisions Science Associates, Incorporated. The Underground Storage Tank Integrated Demonstration funded the task; however, the approach should also be valuable to the US Department of Energy Office of Technology Development, the Office of Waste Management, and the Office of Environmental Restoration.
1994-03-01
Energy Technology Data Exchange (ETDEWEB)
This document outlines the significant accomplishments of fiscal year 1998 for the Tank Waste Remediation System (TWRS) Project Hanford Management Contract (PHMC) team. Opportunities for improvement to better meet some performance expectations have been identified. The PHMC has performed at an excellent level in administration of leadership, planning, and technical direction. The contractor has met and made notable improvement of attaining customer satisfaction in mission execution. This document includes the team`s recommendation that the PHMC TWRS Performance Expectation Plan evaluation rating for fiscal year 1998 be an Excellent.
1998-09-04
Melter system technology testing for Hanford Site low-level tankwaste vitrification
Energy Technology Data Exchange (ETDEWEB)
Following revisions to the Tri-Party Agreement for Hanford Site cleanup, which specified vitrification for Complete melter feasibility and system operability immobilization of the low-level waste (LLW) tests, select reference melter(s), and establish reference derived from retrieval and pretreatment of the radioactive LLW glass formulation that meets complete systems defense wastes stored in 177 underground tanks, commercial requirements (June 1996). Available melter technologies were tested during 1994 to 1995 as part of a multiphase program to select reference Submit conceptual design and initiate definitive design technologies for the new LLW vitrification mission.
1996-05-03
Innovative active control of gun barrels using smart materials
The accuracy of stabilized, turreted gun systems like the 120mm gun on the M1A2 Abrams tank and the 30mm gun on the Apache helicopter are limited by, among other things, structural flexure of the gun barrel and support structure. An advanced actuation system based on piezoelectric translators and an optical fiber strain sensing system are described in conjunction with a rapid prototyping workstation for the design of distributed parameter control systems to actively minimize the effects of vibrations caused by traversing rough terrain or weapon firing.
1997-06-01
Direct dark matter identification with a hybrid detection technique
In the quest to understand the ultimate nature of WIMPs, we propose the use of a hybrid detection technique: cylinders filled with liquefied noble gasses, acting as targets, are immersed inside a tank of Gd-doped ultra-pure water that provides an active and efficient veto against neutrons. The evaluation of the background rejection capabilities and physics potential of this instrument have been carried out through a full GEANT4 simulation, assuming the detector will be located at the Canfranc underground laboratory (in the Spanish Pyrenees). Our results compare very favourably with existing or planned experiments in the field. This technique is scalable and will allow to reach target masses of few tonnes in the next future.
2008-01-01
Development of the alcohol waste processing equipment
International Nuclear Information System (INIS)
In the experimental fast Reactor JOYO, gripper of Fuel Handling Machine and Ex-Vessel Transfer Machine that the sodium adhered is being washed with alcohol. This radioactive alcohol waste that was used to the washing is stored to the tank. If it is able to separate the alcohol and sodium in the alcohol waste it becomes possible to dispose of the alcohol waste. Japan Nuclear Institute and Fuji Electric Systems CO., LTD. Developed the device that adds carbonic acid gas to the alcohol waste and cause the sodium in the alcohol waste separated as carbonate and remove this carbonate by using the thin film evaporator. (author)
2004-11-01
Corrosion 2003. Conference papers on CD-ROM
Energy Technology Data Exchange (ETDEWEB)
Papers are presented under 38 symposia. Subjects included reinforced concrete, protective coatings and linings, cathodic/anodic protection, chemical cleaning of boilers, managing corrosion with plastics, water treatment, HRSG boiler tube failure analysis, corrosion in oil and gas production, corrosion in petroleum refining and gas, processing, pipelines and tanks, high temperature materials, chemical process industry, aerospace equipment, materials technology developments for incinerators and waste fuel-fired processors, materials and corrosion in fossil-fuels conversion and combustion, corrosion in nuclear systems, marine corrosion, building systems, corrosion mechanisms, corrosion inhibitors and corrosion monitoring and measurement.
2003-07-01
Compressed hydrogen fuelled vehicles: reasons of a choice and developments in ENEA
Energy Technology Data Exchange (ETDEWEB)
Some recent achievements in the field of high pressure vessels and safety devices have offered a concrete chance to the application of compressed hydrogen for fleet commercial vehicles for urban use. Accordingly with this concept, ENEA has modified a Fiat Ducato van with a dual fuel engine, retaining the gasoline tank for long distance travelling and adopting the external mixture formation technique, with hydrogen injectors developed by ENEA, for non-polluting short-range duties in urban traffic. The article deals with the rationale for this choice and gives a general view of the project. (author)
1996-12-01
Bringing robotics technology down to Earth
International Nuclear Information System (INIS)
Robotics technology is successfully being transitioned from space to terrestrial applications. It is being modified and enhanced to help in the US DOE's Environmental Restoration and Waste Management Program. Some examples of these applications, ranging from large multijointed manipulators to autonomously navigated remote vehicles, are outlined in this article. They include the following: underground storage tank technology demonstration; light-duty utility arm system; remotely controlled material-handling system; remotely operated excavator; self-guided transfer vehicle. 10 figs.
Analysis of hydrogen vehicles with cryogenic high pressure storage
Energy Technology Data Exchange (ETDEWEB)
Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LIQ) or ambient-temperature compressed hydrogen (CH2). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.
1998-06-19
Thin-film evaporator recovers solvents continuously
Energy Technology Data Exchange (ETDEWEB)
Reclaimed Energy Company, Inc., Connersville, IN, receives waste generated from a wide variety of industrial applications which include paint, printing and degreasing companies. The wastes are stored in separate tanks and then distilled in batches (pot distillation). The recovered solvents can be returned to the originator. The residue, left after the solvents are distilled, is disposed of using an environmentally safe, economical procedure. The company worked with an engineering and fabrication firm to develop a continuous processing system that employs a mechanically agitated thin-film evaporator to distill the solvents. Successful performance of the evaporator was ensured by processing samples of solvents through the evaporator manufacturer's pilot plant facilities before the full-sized system was designed. Reclaimed Energy Company, Inc., has realized a number of advantages by going from pot distillation to the agitated thin-film evaporator system to ...
1985-11-01
International Nuclear Information System (INIS)
The 177 underground storage tanks at the DOE's Hanford Site contain an estimated 180 million tons of high-level radioactive wastes. It is desirable to remove and concentrate the highly radioactive fraction of the tank wastes for vitrification. Resorcinol-formaldehyde (R-F) resin, an organic ion-exchange resin with high selectivity and capacity for the cesium ion, which is a candidate ion-exchange material for use in remediation of tank wastes. The report includes information on the structure/function analysis of R-F resin and the synthetic factors that affect performance of the resin. CS-100, a commercially available phenol-formaldehyde (P-F) resin, and currently the baseline ion-exchanger for removal of cesium ion at Hanford, is compared with the R-F resin. The primary structural unit of the R-F resin was determined to consist of a 1,2,3,4-tetrasubstituted resorcinol ring unit while CS-100, was composed mainly of a ...
2004-09-10
Stationary low power reactor No. 1 (SL-1) accident site decontamination & dismantlement project
The Army Reactor Area (ARA) II was constructed in the late 1950s as a test site for the Stationary Low Power Reactor No. 1 (SL-1). The SL-1 was a prototype power and heat source developed for use at remote military bases using a direct cycle, boiling water, natural circulation reactor designed to operate at a thermal power of 3,000 kW. The ARA II compound encompassed 3 acres and was comprised of (a) the SL-1 Reactor Building, (b) eight support facilities, (c) 50,000-gallon raw water storage tank, (d) electrical substation, (e) aboveground 1,400-gallon heating oil tank, (f) underground 1,000-gallon hazardous waste storage tank, and (g) belowground power, sewer, and water systems. The reactor building was a cylindrical, aboveground facility, 39 ft in diameter and 48 ft high. The lower portion of the building contained the reactor pressure vessel surrounded by gravel shielding. Above the pressure vessel, in the center portion ...
1995-11-01
Salt decontamination demonstration test results
International Nuclear Information System (INIS)
The Salt Decontamination Demonstration confirmed that the precipitation process could be used for large-scale decontamination of radioactive waste sale solution. Although a number of refinements are necessary to safely process the long-term requirement of 5 million gallons of waste salt solution per year, there were no observations to suggest that any fundamentals of the process require re-evaluation. Major accomplishments were: (1) 518,000 gallons of decontaminated filtrate were produced from 427,000 gallons of waste salt solution from tank 24H. The demonstration goal was to produce a minimum of 200,000 gallons of decontaminated salt solution; (2) cesium activity in the filtrate was reduced by a factor of 43,000 below the cesium activity in the tank 24 solution. This decontamination factor (DF) exceeded the demonstration goal of a DF greater than 10,000; (3) average strontium-90 activity in the filtrate was reduced by a factor of 26 to less ...
Evaluation of methods to measure surface level in waste storage tanks: Second test sequence
Energy Technology Data Exchange (ETDEWEB)
This report describes the results of a program conducted at the Pacific Northwest Laboratory (PNL) and Westinghouse Hanford Company (WHC) to identify alternative methods to measure the surface level in the waste tanks. This program examined commercially available devices for measuring the distance to a target. This is a continuation of a program started in FY93. In the first test sequence, tests were performed.on five devices to determine their applicability to measure the surface level in the waste tanks. The devices were the Enraf-Nonius{trademark} Model 872 Radar Gauge, the Enraf-Nonius{trademark} Model 854 Advanced Technology Gauge (ATG), the Stanley Tool Laser Measuring Device, the Robertshaw Inven-Tel{reg_sign} Precision Level Gauge, and the Micro Switch Model 942 Acoustic Sensor. In addition, discussions were held with several manufacturer representatives regarding other potential devices. The results of these tests were documented in a ...
1993-09-01
Comparison between experimental data and numerical modeling for the natural circulation phenomenon
Energy Technology Data Exchange (ETDEWEB)
There is a crescent interest in the scientific community in the study of natural circulation phenomenon. New generation of compact nuclear reactors uses the natural circulation of the fluid as a system of cooling and of residual heat removal in case of accident or shutdown. The objective of this paper is to present a study through the comparison of experimental data and numerical simulation for the natural circulation phenomenon in one and two-phase flow regime. An experimental circuit built with glass tubes is used for the experiments. Thus, it allows the thermal hydraulic phenomena visualization. There is an electric heater as the heat source, a heat exchanger as the heat sink and an expansion tank to accommodate fluid density excursions. The circuit instrumentation consists of thermocouples and pressure meters to better keep track of the flow and heat transfer phenomena. Instrumentation data acquisition is performed through a computer interface developed with ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
A home-made 3.1 kWh wind turbine that is promising to be the hottest new wind product to appear for home/farm users in some time, is described. The turbine is installed near a farm house in the high wind area of Mount Forest, Ontario. The turbine is hooked up to a four kilowatt Trace inverter charger which is coupled through a DC disconnect and C-60 charge controller to two sets of solar panels (seven panels of 120 W each by Solarex SX 120, and five panels by Sharp, each providing 1600 watt of solar power). The wind turbine and the solar panels, assisted by two 65-year old refurbished wind turbines, one bank of Gel Cell batteries, and an Onan 5 kW gas generator supply the electrical requirements of a seven member family in a 3400 square foot house. The new turbine is mounted on an 80-foot tower, has three eight foot Kevlar blades that produce a 17 foot overall sweep. The turbine weighs 615 lbs., produces 3.1 kW of pure power at just 310 rpms at ...
2004-12-31
Energy Technology Data Exchange (ETDEWEB)
Soils and food crops from a former tin mining location in a high background radiation area on the Jos-Plateau, Nigeria were collected and analyzed by gamma spectrometry to measure their contents of {sup 40}K, {sup 238}U and {sup 232}Th. As well as collecting samples, in situ dose rates on farms were measured using a precalibrated survey meter. Activity concentrations determined in food crops were compared with the local food derivatives or diets to investigate the possible removal or addition of radionuclides during food preparation by cooking or other means. Potassium-40 was found to contribute the highest activity in all the food products. The activity concentration of {sup 40}K, {sup 238}U and {sup 232}Th in local prepared diets ranged between 60 and 494 Bq kg{sup -1}, between BDL and 48 Bq kg{sup -1} and between BDL and 17 Bq kg{sup -1}, respectively. The internal effective dose to individuals from the consumption of the food types was estimated on the basis of ...
2007-04-15
International Nuclear Information System (INIS)
Soils and food crops from a former tin mining location in a high background radiation area on the Jos-Plateau, Nigeria were collected and analyzed by gamma spectrometry to measure their contents of "4"0K, "2"3"8U and "2"3"2Th. As well as collecting samples, in situ dose rates on farms were measured using a precalibrated survey meter. Activity concentrations determined in food crops were compared with the local food derivatives or diets to investigate the possible removal or addition of radionuclides during food preparation by cooking or other means. Potassium-40 was found to contribute the highest activity in all the food products. The activity concentration of "4"0K, "2"3"8U and "2"3"2Th in local prepared diets ranged between 60 and 494 Bq kg"-"1, between BDL and 48 Bq kg"-"1 and between BDL and 17 Bq kg"-"1, respectively. The internal effective dose to individuals from the consumption of the food types was estimated on the basis of the measured radionuclide ...
2007-04-01
Energy Technology Data Exchange (ETDEWEB)
Biomass is a potential source of energy that can reduce our dependency on oil as the main source of energy. In addition to municipal solid waste, animal and olive wastes are the main sources of organic waste in Jordan. In 2005, there were more than 2.4 million heads of sheep, about 72 thousand cows, and 40 million hens being raised in farms distributed in all governorates of Jordan. These animals produce 5.3 million tons (as exerted) of solid waste per year. If these quantities can be effectively collected they may constitute a valuable source of energy. This paper is aiming to estimate the amounts of animal and solid wastes generated in Jordan and their energy potential. The total amount of BOD from animal waste is estimated at 200,000 tons per year. Significant quantities of organic waste can also be collected from olive mills distributed in the country. This waste known locally as ''Jift'' is currently being collected and used ...
2010-10-15
Energy Technology Data Exchange (ETDEWEB)
Environmental and breathing zone samples were analyzed for formaldehyde at the Pikes Peak Dialysis Center, Colorado Springs, Colorado in August, 1984 and February, 1985. The evaluation was requested by a representative of the Center to determine if there was a health hazard due to formaldehyde. Eight employees were interviewed. The ventilation systems were investigated. Personal protective clothing was inspected. Breathing-zone samples contained 0 28 to 1.0 (mg/m/sup 3/) formaldehyde. The OSHA standard for formaldehyde is 3.7 mg/m/sup 3/. Area formaldehyde concentrations ranged from nondetectable to 0.75 mg/m/sup 3/. Health complaints reported included sore throat, congestion, cough, and eye, nose and throat irritation. Most of the complaints originated from employees in the formalin mixing, reuse sterilization, and dialysis unit packing sections. The exhaust system in the reuse sterilization area was not working efficiently. A variety of personal protective ...
1985-08-01
Energy Technology Data Exchange (ETDEWEB)
For an air conditioned building, the major electricity consumption is by the heating, and air conditioning (HVAC) system. As energy saving strategies may be in conflict with the criteria of indoor air quality and thermal comfort, a concept of the building environmental performance model (BEPM) has been developed to optimize energy consumption in HVAC systems without any deterioration of the indoor air quality and thermal comfort. The BEPM is divided into two main modules: the adaptive comfort temperature (ACT) module and the new demand control ventilation (nDCV) module. This study aims to enhance and prompt the conventional operation of the air side systems by incorporating temperature reset with the adaptive comfort temperature control and the new demand control ventilation system in high rise buildings in Hong Kong. A new example weather year (1991) was established as a reference to compute the energy use of HVAC systems in buildings in order ...
2006-09-15
Hydrogen storage in nano-structured carbon materials
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical ...
2005-07-01
Hydrogen storage in nano-structured carbon materials
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical ...
2005-07-01
The advanced MAPLE reactor concept
International Nuclear Information System (INIS)
High-flux neutron sources are continuing to be of interest both in Canada and internationally to support materials testing for advanced power reactors, new developments in extracted-neutron-beam applications, and commercial production of selected radioisotopes. The advanced MAPLE reactor concept has been developed to meet these needs. The advanced MAPLE reactor is a new tank-type D_2O reactor that uses rodded low-enrichment uranium fuel in a compact annular core to generate peak thermal-neutron fluxes of 1 x 10"1"9 n#centre dot#s"-"1 in a central irradiation rig with a thermal power output of 50 MW. Capital and incremental development costs are minimized by using MAPLE reactor technology to the greatest extent practicable.
1985-10-14
Energy Technology Data Exchange (ETDEWEB)
Surveillance and maintenance (S & M) of 75 sites were conductd by the Remedial Action Section for the Environmental Restoration Program for surplus facilities and sites contaminated with radioactive materials and/or hazardous chemicals. S & M activities on these sites were conducted from the end of their operating life until final facility disposal or site stabilization. The objectives of the Waste Area Grouping S & M Program are met by maintaining a program of routine S & M as well as by implementing interim corrective maintenance when deemed necessary as a result of site surveillance. This report briefly presents this program`s activities and includes tables indicating tank levels and dry well data for FY 1991.
1991-12-01
Surveillance and maintenance activities of waste area groupings at Oak Ridge National Laboratory
Energy Technology Data Exchange (ETDEWEB)
Surveillance and maintenance (S M) of 75 sites were conductd by the Remedial Action Section for the Environmental Restoration Program for surplus facilities and sites contaminated with radioactive materials and/or hazardous chemicals. S M activities on these sites were conducted from the end of their operating life until final facility disposal or site stabilization. The objectives of the Waste Area Grouping S M Program are met by maintaining a program of routine S M as well as by implementing interim corrective maintenance when deemed necessary as a result of site surveillance. This report briefly presents this program's activities and includes tables indicating tank levels and dry well data for FY 1991.
1991-12-01
Surface-loss power calculations for the LANSCE DTL
Energy Technology Data Exchange (ETDEWEB)
The surface losses in the drift-tube linac (DTL) tanks 3 and 4 of the LANSCE linear accelerator are calculated using 3-D electromagnetic modeling with the CST MicroWave Studio (MWS). The results are used to provide more realistic power estimates for the 201.25MHz RF upgrade design within the LANSCE-R project. We compared 3-D MWS results with those from traditional 2-D Superfish computations for DTL cells and their simplified models and found differences on the level of a few percent. The differences are traced to a 3-D effect consisting in a redistribution of the surface currents on the drift tubes (DT) produced by the DT stem. The dependence of MWS results on the mesh size used in computations is also discussed.
2008-01-01
Solid suspension in stirred tanks: UVP measurements and CFD simulations
British Library Electronic Table of Contents (United Kingdom)
Abstract Suspension of solids in stirred reactor is widely used for catalytic reactions, dissolution, etc. Quality of solid suspension is an important parameter required for the reliable design, optimum performance, and scale up of the system. Quality of suspension depends on local characteristics of solid velocity and hold up profiles. The present work was focused on investigating quality of solid suspension using ultrasound velocity profiler (UVP) measurements and CFD simulations. The slip velocity measurements carried out with UVP were used to evaluate different drag correlations used in CFD simulations. Results discussed in this work would be useful for extending the applications of CFD models for simulating large stirred slurry reactors.
2011-01-01
Solar distillation as an appropriate technology tool in Haiti
Energy Technology Data Exchange (ETDEWEB)
Source Philippe (on the island of La Govave, near Haiti) is described in terms of climatic, sociological, agricultural and technical background. Because of drought conditions, it became necessary to develop a solar still to provide the town with sufficient fresh water. The still, which has been in operation since 1969, is described in some detail as is the construction process. Brackish and sea water are used to produce more than 1250 liters of fresh water each day. A windmill is used to pump the brackish water from a well to an elevated storage tank; it flows by gravity to solar still basins where it is vaporized, then condensed on a sloping glass surface and collected. Benefits of the solar still to the town's economy and health are discussed. Cost of the project was $17,000. 10 references. (MJJ)
1980-06-01
Silver removal process development for the MEO cleanout
Energy Technology Data Exchange (ETDEWEB)
The Mediated Electrochemical Oxidation (MEO) system is an aqueous process which treats low-level mixed wastes by oxidizing the organic components of he waste into carbon dioxide and water. As MEO system continues to run, dissolved ash and radionuclides slowly accumulate in the anolyte and must be removed to maintain process efficiency. At such time, all of the anolyte is pumped into a still feed tank, and the silver ions need to be removed before sending the solution to a thin-film evaporator for further concentration. The efficiency of removing silver ions in the solution needs to be high enough such that the residual silver sent to Final Forms would be less than 1% wt. The purpose of this work is to develop an efficient process to remove silver ions during the MEO cleanout and to demonstrate the capability of centrifugation for separating small silver chloride particles from the solution. This development work includes lab scale experiments and bench scale tests. ...
1996-02-01
Rotary Mode Core Sample System availability improvement
Energy Technology Data Exchange (ETDEWEB)
The Rotary Mode Core Sample System (RMCSS) is used to obtain stratified samples of the waste deposits in single-shell and double-shell waste tanks at the Hanford Site. The samples are used to characterize the waste in support of ongoing and future waste remediation efforts. Four sampling trucks have been developed to obtain these samples. Truck I was the first in operation and is currently being used to obtain samples where the push mode is appropriate (i.e., no rotation of drill). Truck 2 is similar to truck 1, except for added safety features, and is in operation to obtain samples using either a push mode or rotary drill mode. Trucks 3 and 4 are now being fabricated to be essentially identical to truck 2.
1995-02-28
Preconceptual study of an advanced MAPLE research reactor
International Nuclear Information System (INIS)
The Advanced MAPLE is a research reactor design under development as a high-flux neutron source. The main performance goals for the reactor are a high peak thermal neutron flux in a heavy-water reflector tank, and a high average fast neutron flux in a central irradiation facility, with a maximum linear fuel rod rating of less than 120 kW/m. This study investigated the neutronic and reactor design consequences of the use of H_2O coolant as opposed to D_2O. The neutronics results, and several other considerations, indicate that H_2O coolant has a number of advantages. It is suggested that the H_2O coolant option be considered in the design of the Advanced MAPLE reactor. (L.L.) 9 refs., 4 figs., tab.
1990-06-03
Oil-tanker waste-disposal practices: A review
Energy Technology Data Exchange (ETDEWEB)
In the spring of 1991, the Environmental Protection Agency, Region 10 (EPA), launched an investigation into tanker waste disposal practices for vessels discharging ballast water at the Alyeska Pipeline Services Company's Ballast Water Treatment (BWT) facility and marine terminal in Valdez, Alaska. It had been alleged that the Exxon Shipping Company was transferring 'toxic wastes originating in California' to Valdez. In response, EPA decided to examine all waste streams generated on board and determine what the fate of these wastes were in addition to investigating the Exxon specific charges. An extensive Information Request was generated and sent to the shipping companies that operate vessels transporting Alaska North Slope Crude. Findings included information on cargo and fuel tank washings, cleaning agents, and engine room waste.
1992-01-01
Oak Ridge Research Reactor. Quarterly report, July, August, and September 1984
Energy Technology Data Exchange (ETDEWEB)
The ORR operated at an average power level of 29.7 MW for 85.3% of the time during this period. The reactor was shut down on fifteen occasions, nine of which were unscheduled. Reactor downtime needed for refueling and checks was normal. The reactor remained available for operation 88.3% of the time. Special tests completed during the quarter included: (1) transfer of LEU fuel elements CLE-202 and NLE-201 from core positions B-9 and B-2 to core positions C-5 and C-6 for continued operation; and (2) calculation of maximum heat flux in LEU elements CLE-201 and NLE-202 in core positions A-2 and A-8. In-service inspections included inspections of ORR decay tank, primary heat exchanger No. 4, and the 24-in. strainer.
1985-03-01
Monte Carlo methods, models, and applications for the Advanced Neutron Source
Energy Technology Data Exchange (ETDEWEB)
A three-dimensional, continuous-energy, coupled neutron-gamma Monte Carlo model of the advanced neutron source (ANS) final preconceptual reference core design has been developed using MCNP Version 3b. This model contains the reactor core with control rods, the heavy-water reflector tank with shutdown rods and representative beam tubes, and the outer light-water poor. Eighty homogenized fuel zones per fuel element are used to represent the radical and axial {sup 235}U fuel grading. This model is the most sophisticated, physically accurate reactor physics model of the ANS currently available. The purpose of this summary is to demonstrate the MCNP methods and applications for the ANS.
1990-06-01
Monosodium titanate particle characterization
Energy Technology Data Exchange (ETDEWEB)
A characterization study was performed on monosodium titanate (MST) particles to determine the effect of high shear forces expected from the In-Tank Precipitation (ITP) process pumps on the particle size distribution. The particles were characterized using particle size analysis and scanning electron microscopy (SEM). No significant changes in particle size distributions were observed between as-received MST and after 2--4 hours of shearing. Both as-received and sheared MST particles contained a large percentage of porosity with pore sizes on the order of 500 to 2,000 Angstroms. Because of the large percentage of porosity, the overall surface area of the MST is dominated by the internal surfaces. The uranium and plutonium species present in the waste solution will have access to both interior and exterior surfaces. Therefore, uranium and plutonium loading should not be a strong function of MST particle size.
1993-01-12
Measuring the scale of segregation in mixing data
British Library Electronic Table of Contents (United Kingdom)
Abstract Four methods were used to extract length scales from mixing data: the maximum striation thickness, point-to-nearest-neighbour (PNN) distributions, the correlogram and the variogram. Four test data sets were analysed: blending in a micromixer; particle dispersion in a stirred tank; dispersion of a smoke plume and a pulse tracer test in a reactor. The maximum striation thickness captures the largest length scale. The PNN method quantifies differences between clustered, random and regular spatial distributions. The correlogram calculation cannot be consistently used for all types of mixing data and has therefore been rejected. The variogram reveals both large-scale segregation and periodicity. Sub-sampling is needed to isolate smaller structures. The variogram, PNN and transect metho...
2011-01-01
High pressure in situ diffraction studies of metal-hydrogen systems
British Library Electronic Table of Contents (United Kingdom)
''Hybrid'' hydrogen storage, where hydrogen is stored in both the solid material and as a high pressure gas in the void volume of the tank can improve overall system efficiency by up to 50% compared to either compressed hydrogen or solid materials alone. Thermodynamically, high equilibrium hydrogen pressures in metal-hydrogen systems correspond to low enthalpies of hydrogen absorption-desorption. This decreases the calorimetric effects of the hydride formation-decomposition processes which can assist in achieving high rates of heat exchange during hydrogen loading-removing the bottleneck in achieving low charging times and improving overall hydrogen storage efficiency of large hydrogen stores. Two systems with hydrogenation enthalpies close to -20kJ/mol H2 were studied to investigate the h...
2011-01-01
Hanford Waste Management Plan, 1987
Energy Technology Data Exchange (ETDEWEB)
The purpose of the Hanford Waste Management Plan (HWMP) is to provide an integrated plan for the safe storage, interim management, and disposal of existing waste sites and current and future waste streams at the Hanford Site. The emphasis of this plan is, however, on the disposal of Hanford Site waste. The plans presented in the HWMP are consistent with the preferred alternative which is based on consideration of comments received from the public and agencies on the draft Hanford Defense Waste Environmental Impact Statement (HDW-EIS). Low-level waste was not included in the draft HDW-EIS whereas it is included in this plan. The preferred alternative includes disposal of double-shell tank waste, retrievably stored and newly generated TRU waste, one pre-1970 TRU solid waste site near the Columbia River and encapsulated cesium and strontium waste.
1987-01-01
International Nuclear Information System (INIS)
Geologic studies in connection with Project Discus Thrower have furnished detailed stratigraphic and structural information about northwestern Yucca Flat, Nevada Test Site. The Paleozoic rocks consist of a lower carbonate sequence, argillite of the Eleana Formation, and an upper carbonate sequence. The distribution of these rocks suggests that both top and bottom of the Eleana are structural contacts, probably thrusts or reverse faults. The overlying tuff includes several units recognized in the subsurface, such as the Fraction Tuff and tuff of Redrock Valley. Other units recognized include bedded tuff associated with the Grouse Canyon Member of Belted Range Tuff, and the Rainier Mesa and Ammonia Tanks Members of the Timber Mountain Tuff. The Timber Mountain and Grouse Canyon are extensively altered to montmorillonite (a swelling clay), possibly as a result of ponding of alkaline water. The overlying alluvium locally contains at the base a clayey, tuffaceous ...
Energy Technology Data Exchange (ETDEWEB)
Several natural gas vehicles have been built as part of Ford's Alternative Fuel Demonstration Fleet. Two basic methods, compressed gas (CNG), and liquified gas (LNG) were used. Heat transfer danger and the expense and special training needed for LNG refueling are cited. CNG in a dual-fuel engine was demonstrated first. The overall results were unsatisfactory. A single fuel LNG vehicle was then demonstrated. Four other demonstrations, testing different tank weights and engine sizes, lead to the conclusion that single fuel vehicles optimized for CNG use provide better fuel efficiency than dual-fuel vehicles. Lack of public refueling stations confines use to fleet operations.
1983-06-01
Flooding characteristics of gas-liquid two-phase flow in a horizontal U bend pipe
International Nuclear Information System (INIS)
To evaluate safety of horizontal steam generator used in passive safety system, it is needed to make clear flooding characteristics in U bend pipe. In this study, two-phase flow experiment in a horizontal U bend pipe was carried out to make clear the influence of the length of horizontal pipe and the radius of U bend. Flooding in the U bend pipe was observed in the condition of lower gas or liquid volumetric flux than that in the horizontal pipe or the vertical pipe. Flooding and carry-up in the U bend pipe is hardly change with increasing the length between the water inlet and the U bend, but greatly related with the length from the water inlet to the lower tank and the shape of the U bend inlet. (author).
1994-05-01
FY 1974 NPS independent development program
Thirteen summaries of exploratory development work carried out under a grant to the Naval Postgraduate School Research Foundation are included. This research was carried out in the areas of electrical engineering (slot lines; phase lock loops), aeronautics (aircraft survivability; composite materials for structures), material sciences (relation between high temperature compressive behavior and microstructure), mechanical engineering (fatigue life of ferrocement hull structures; flow fields), economics (hazardous employment incentives for DoD personnel), operations research (missile allocation modeling; combat dynamics; shipboard tank designs), oceanography breakwater construction effects on ecology), and physics (evaluation of an underwater acoustic parametric source).
1975-07-01
Experimental assessment of energy storage via variable speed compressor
British Library Electronic Table of Contents (United Kingdom)
In this study, usage of a variable speed refrigeration system in latent heat thermal energy storage (LHTES) system is investigated to increase energy storage efficiency. Four different compressor speed control cases are compared to obtain a constant heat transfer fluid (HTF) temperature at the inlet of the energy storage tank. These control cases are (i) control with evaporation temperature, (ii) control with ethylene glycol temperature at the outlet section of evaporator, (iii) control with suction pressure of the compressor and (iv) on/off control. By means of the experimental analysis the best control strategy is obtained as control with Case (ii), in terms of stability of inlet temperature of heat transfer fluid, variations of energy efficiency of LHTES and coefficient of performance (...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
This report describes the physical characteristics of a ceramic-lined, joule-heated glass melter that is directly connected to the discharge of a spray calciner and is currently being used to study the vitrification of simulated nuclear-waste slurries. Melter performance characteristics and subsequent design improvements are described. The melter contains 0.24 m/sup 3/ of glass with a glass surface area of 0.76 m/sup 2/, and is heated by the flow of an alternating current (ranging from 600 to 1200 amps) between two Inconel-690 slab-type electrodes immersed in the glass at either end of the melter tank. The melter was maintained at operating temperature (900 to 1260/sup 0/C) for 15 months, and produced 62,000 kg of glass. The maximum sustained operating period was 122 h, during which glass was produced at the rate of 70 kg/h.
1980-11-01
Control of linear accelerator noise in the Los Alamos free-electron laser (FEL)
International Nuclear Information System (INIS)
FELs require tight control of the amplitudes and phase of the fields in two linear accelerator tanks to obtain stable lasing. The accelerator control loops must establish constant, stable, repeatable amplitudes and phases of the rf fields and must have excellent bandwidth to control high-frequency noise components. A model of the feedback loops has been developed that agrees well with measurements and allows easy substitution of components and circuits, thus reducing breadboarding requirements. The model permits both frequency and time-domain analysis. The accelerator control scheme and model are described and the control of noise in feedback loops is discussed, showing how low-frequency-noise components (errors) can be corrected, but high-frequency-noise components (errors) are actually amplified by the feedback circuit. Measurements of noise in both open- and closed-loop modes is shown and comparison is made with results from the model calculations.
1986-09-01
Contamination and restoration of groundwater aquifers
Energy Technology Data Exchange (ETDEWEB)
Humans are exposed to chemicals in contaminated groundwaters that are used as sources of drinking water. Chemicals contaminate groundwater resources as a result of waste disposal methods for toxic chemicals, overuse of agricultural chemicals, and leakage of chemicals into the subsurface from buried tanks used to hold fluid chemicals and fuels. In the process, both the solid portions of the subsurface and the groundwaters that flow through these porous structures have become contaminated. Restoring these aquifers and minimizing human exposure to the parent chemicals and their degradation products will require the identification of suitable biomarkers of human exposure; better understandings of how exposure can be related to disease outcome; better understandings of mechanisms of transport of pollutants in the heterogeneous structures of the subsurface; and field testing and evaluation of methods proposed to restore and cleanup contaminated aquifers. In this review, ...
1993-04-01
Advanced resin cleaning system
International Nuclear Information System (INIS)
Novel and unprecedented ion exchange resin cleaning system, for use in BWR plants and featuring a vibration separator and basic design factors of Radiological Solutions, Inc., had been delivered to Tokai No. 2 Power Station, Japan Atomic Power Company, in October 2005. This compactly-designed system effectively separates crud and resin fines from ion exchange resins, with no clogging of separation screens. It generates minimized waste liquid and has a specially designed over-pack cleaning tank. The system has been in operation for about 2 years and half now and favorable operational data, such as crud and sulfate concentration decrease in feed water and reactor water respectively, and evaluation results have been reported from Japan Atomic Power Company and so on. (author)
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
The T Plant facilities in the 200-West Area of the Hanford site were constructed in the early 1940s to produce nuclear materials in support of national defense activities. T Plant includes the 271-T facility, the 221-T facility, and several support facilities (eg, 2706-T), utilities, and tanks/piping systems. T Plant has been recommended as the primary interim decontamination facility for the Hanford site. Project W-259 will provide capital upgrades to the T Plant facilities to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. This document provides an advanced conceptual design concept that complies with functional requirements for the T Plant Secondary Containment and Leak Detection upgrades.
1995-05-12
The concentration decay curves for the adsorption of phenol on organobentonite were obtained in an agitated tank batch adsorber. The experimental adsorption rate data were interpreted with diffusional models as well as first-order, second-order and Langmuir kinetic models. The surface diffusion model adjusted the data quite well, revealing that the overall rate of adsorption was controlled by surface diffusion. Furthermore, the surface diffusion coefficient increased raising the mass of phenol adsorbed at equilibrium and was independent of the particle diameter in the range 0.042-0.0126cm. It was demonstrated that the overall rate of adsorption was essentially not affected by the external mass transfer. The second-order and the Langmuir kinetic models fitted the experimental data quite well; however, the kinetic constants of both models varied without any physical meaning while increasing the particle size and the mass of phenol adsorbed at equilibrium. ...
2011-08-22
Energy Technology Data Exchange (ETDEWEB)
In the present work, the process of carbon dioxide absorption is analyzed at high partial pressures, in aqueous solutions of 1-amino-2-propanol (monoisopropanolamine (MIPA)), in relation to the thermal effects involved. All experiments were made in a stirred-tank reactor with a plane unbroken gas-liquid interface. The variables considered were the MIPA concentration within the range 0.1--2.0 M and the temperature within the interval 288--308 K. From the results, the authors deduce that the absorption process takes place in the nonisothermal instantaneous regime and propose an equation which not only relates the experimental results of flow density with the initial concentration of amine but at the same time enables the evaluation of the rise in temperature in the gas-liquid interface.
1997-10-01
A Study on A Semi-Submersible Floating Offshore Wind Energy Conversion System
Energy Technology Data Exchange (ETDEWEB)
A new semi-submersible floating structure is proposed on which three wind turbine towers are installed. This paper presents a basic characteristic of the wave-induced motion of this semi-submersible floating structure via. numerical computations and 1/150 scaled rigid model experiments in a wave tank. In the numerical computations, nonlinear damping effect due to drag forces modeled by the Morison's formula is considered in the equation of motion, where the linear hydrodynamic forces are obtained from the Green's function model. As a result, the response characteristics around the resonant frequency region were successfully improved. In addition to such basic examination, major results of feasibility studies, including the structural stability for severe wave conditions and the long-term fatigue limit state, are presented for a realistic situation.
2007-07-01
Wind power data transmission challenges; Les defis de la transmission de donnees en eolien
Energy Technology Data Exchange (ETDEWEB)
This presentation outlined the corporate history of the Ohmega Group, a small company from Gaspe, Quebec which offers consulting services to the automation and telecommunication sector. It was created in 1982 and has been involved with the wind power industry since 1996. The main services provided by Ohmega Group include electrical and mechanical construction and maintenance services. This paper also reviewed the benefits of using Supervisory Control and Data Acquisition (SCADA) systems in the wind power industry to monitor, control and collect data from wind turbines. The Ohmega Group has provided consulting services to Cartier Wind Energy Inc., a company that was awarded several wind turbine projects by Hydro-Quebec Distribution. The Ohmega Group applied the SCADA system at the Baie des Sables, Anse a Valleau and Carleton wind turbine arrays. The typical architecture of SCADA systems on a wind farm was presented along with Hydro-Quebec's specifications ...
2008-07-01
Valuing climate protection through willingness to pay for biomass ethanol
Energy Technology Data Exchange (ETDEWEB)
This study uses a multi-part, split-sample contingent valuation method (CVM) and fair share (FS) survey to better understand the public's valuation of mitigating global climate change through its willingness to pay for biomass or 'cellulosic' ethanol. In addition to a basic CVM question, a related scenario was developed that asked half of the survey respondents to state their fair share cost to lessen a potential food shortage in the next decade, also through the expanded use of cellulosic ethanol. Three alternative biomass feedstocks were assessed: farming residues, forestry residues and paper mill wastes, and municipal solid wastes. Overall a slightly larger proportion of respondents were WTP extra for cellulosic ethanol in the basic CVM scenario than in the FS scenario, though no significant differences were found in the WTP for the different feedstocks. Bid curve lognormal regression results for the two models were similar, supporting ...
2009-05-15
Energy Technology Data Exchange (ETDEWEB)
Water protection wetlands aim to reduce nitrogen and phosphorous concentrations either separately or simultaneously. In the latter case, a wetland must contain parts differing clearly in both function and physical condition. In efforts to reduce nitrogen the most important process is denitrification. Phosphorus is deposited with solids and bound to the vegetation and soil in wetlands. As the bulk of the solid and nutrient load comes from catchments during spring floods, wetlands should be designed on the basis of, at least, the average maximum vernal run-off (MHq). Use of higher run-offs, e.g. MHql/10 or MHql/20, in the design without reducing the target retention would require large wetlands. The efficiency of wetlands is constrained by too short retention times and low leachate temperatures. Wetlands established with special environmental support are normally designed on the basis of MHq. The average catchment area of such wetlands is 1.86 km{sup 2} median 0.53 km{sup 2}. The ...
1998-12-31
International Nuclear Information System (INIS)
The outcome was retrospectively examined and prognostic factors were discussed for arterial chemo-infusion therapy (ACT) through an implanted reservoir system and radiation therapy (RT) in patients with unresectable intrahepatic cholangiocarcinoma (CCC). ACT plus RT were conducted to 25 patients (mean age 61.7 y, M/F 12/13, stage III-IVB) during 10 years from 1996 to 2005 with various regimens of cisplatin (CDDP), 5- fluorouracil (FU), epirubicin (FARM), mitomycin C (MMC) plus 39-50 Gy of radiation in a fractionated manner partly involving internal RT (2 cases, 15 Gy) and RT for metastatic bone (1, 25 Gy). The survival rates at 1, 2 and 3 years after ACT+RT were respectively 52.5, 43.7 and 28.1%; total efficacy (PR) was 36% (9/25) at 6 months; and significantly good prognostic factors were found to be female and absence of metastasis remote and/or lymphatic around artery. Authors concluded that ACT+RT was a meaningful treatment for highly advanced non-respectable ...
2007-11-01
International Nuclear Information System (INIS)
Reproductive parameters were monitored in 50 post-partum Bos indicus x Bos taurus animals located on four farms in two ecological zones of Panama. Progesterone (P_4) concentrations were measured in four of these animals twice a week and their reproductive organs palpated per rectum once a week until 60 days post-artificial-insemination or post-natural-service. The other 46 cows were palpated for early pregnancy between days 45 and 60 post-service. The mean P_4 concentration in cows with palpable corpora lutea (CL) was 10.3#+-#4.0 nmol/L; when no Cl were detected, the mean P_4 level was 2.2#+-#1.6 nmol/L. Of the 46 animals palpated for early pregnancy, 36 (70%) were found to be pregnant, one (2%) exhibited early embryonic death and one (2%) aborted; the other eight cows (17%) were anoestrous. The mean P_4 concentration in pregnant cows was 11.9#+-#4.0 nmol/L and the calving to conception interval was 148 days. (author). 13 refs, 7 figs, 4 tabs.
International Nuclear Information System (INIS)
Reliability has an impact on wind energy project costs and benefits. Both life test data and field failure data can be used for reliability analysis. In wind energy industry, wind farm operators have greater interest in recording wind turbine operating data. However, field failure data may be tainted or incomplete, and therefore it needs a more general mathematical model and algorithms to solve the model. The aim of this paper is to provide a solution to this problem. A three-parameter Weibull failure rate function is discussed for wind turbines and the parameters are estimated by maximum likelihood and least squares. Two populations of German and Danish wind turbines are analyzed. The traditional Weibull failure rate function is also employed for comparison. Analysis shows that the three-parameter Weibull function can obtain more accuracy on reliability growth of wind turbines. This work will be helpful in the understanding of the reliability growth of wind energy ...
2009-06-01
Energy Technology Data Exchange (ETDEWEB)
Biogas, produced from anaerobic digestion of organic matter in domestic, industrial and rural wastewaters and residuals, represent an alternative and renewable source of energy, with growing use worldwide. In Brazil, high population and its spatial concentration and expressive agricultural and agricultural-industrial production indicate a substantial potential of biogas production. The results presented in this work show a potential of biogas production of almost 2 billion cubic feet a day of CH{sub 4}. Viability of biogas production and use depends substantially on project scale. Generally, biogas projects are viable from landfills and domestic wastewater treatment for populations higher than 50,000 inhabitants and swine and dairy farms with at least 5,000 and 1,000 animals, respectively. Biogas is also competitive when compared to fossil fuels used in industry and transport. Despite incentive mechanisms for biogas production and use, like Clean Development ...
2009-12-15
Energy Technology Data Exchange (ETDEWEB)
This report is a summary of the contribution of nitrogen and phosphorus in the eutrophication process of inland and coastal waters. Special attention was paid to the mechanisms of these nutrients in regulating biological processes and to the methods available in estimating their effects in the eutrophication of water bodies. The report includes five chapters which are entitled: Introduction, which is a general background to the subject with special attention to the requirements of the Finnish Water Act. Phosphorus and nitrogen as factors regulating biological processes. The topics included are: definition of eutrophication, forms of phosphorus and nitrogen and their sources to inland and coastal waters, effects of these nutrients as growth factors of phytoplankton and macrophytes and consequences of eutrophication. Estimation of the effects of phosphorus and nitrogen. The topics discussed from the point of view of the tasks of the National Board of Waters and the Environment are: ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
This guide explained the requirements for Off-Road Compression Ignition Engine Emission Regulations established under the Canadian Environmental Protection Act. The regulations are enforced by Environment Canada, which authorizes and monitors the use of the national emissions mark. The regulations prescribe standards for off-road engines that operate as reciprocating, internal combustion engines, other than those that operate under characteristics similar to the Otto combustion cycle and that use a spark plug or other sparking device. The regulations apply to engines that are typically diesel-fuelled and found in construction, mining, farming and forestry machines such as tractors, excavators and log skidders. Four different types of persons are potentially affected by the regulations: Canadian engine manufacturers; distributors of Canadian engines or machines containing Canadian engines; importers of engines or machines for the purpose of sale; and persons not in ...
2006-03-15
International Nuclear Information System (INIS)
This guide explained the requirements for Off-Road Compression Ignition Engine Emission Regulations established under the Canadian Environmental Protection Act. The regulations are enforced by Environment Canada, which authorizes and monitors the use of the national emissions mark. The regulations prescribe standards for off-road engines that operate as reciprocating, internal combustion engines, other than those that operate under characteristics similar to the Otto combustion cycle and that use a spark plug or other sparking device. The regulations apply to engines that are typically diesel-fuelled and found in construction, mining, farming and forestry machines such as tractors, excavators and log skidders. Four different types of persons are potentially affected by the regulations: Canadian engine manufacturers; distributors of Canadian engines or machines containing Canadian engines; importers of engines or machines for the purpose of sale; and persons not in ...
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from consumption of agricultural plants and farm animal products are made routinely and reported annually for those produced offsite, using information about concentrations of ...
1990-10-01
Integrated risk analysis of a heavy-metal-contaminated site in Taiwan
Energy Technology Data Exchange (ETDEWEB)
The Love Canal episode began the long battle on hazardous wastes in the United States. Obviously, the potential danger of hazardous wastes is one of the hottest issues among environmental professionals as well as the public. The problems of hazardous wastes in economically booming Taiwan are also alarming. Several farmlands in northern Taiwan were contaminated heavily by industrial effluents containing heavy metals (cadmium and lead) in the early 1980s. Regardless of the many studies that have been conducted about these polluted farmlands, there has not been any remediation - just a passive abandonment of farming activities with minimal compensation. This paper addresses a heavy-metal-contaminated fanning area. A pollution profile across time is delineated using information from the abundance of reports, and the contamination is modeled mathematically. The past, the present, and future exposures are also modeled. The results are presented in terms of societal ...
1996-12-31
Influence of nutrition and suckling patterns on the postpartum cyclic activity of swamp buffaloes
International Nuclear Information System (INIS)
Two studies were conducted to investigate the effects of nutrition and suckling patterns on the ovarian cyclicity of postpartum buffaloes. In Study 1, which was conducted on an institutional farm, two different diets were fed to 24 buffaloes during late gestation and postpartum period. Restricted (twice daily) suckling began on day 30 postpartum in half the animals on each diet. The body weight of both ad libitum suckled and twice daily suckled groups declined during the postpartum period, irrespective of the diet fed. Buffaloes subjected to restricted suckling lost less body weight and re-established ovarian cyclicity earlier than those suckled ad libitum. In Study 2, which was conducted under village conditions, temporary calf removal for 72 hours on days 91-93 postpartum in anoestrous buffaloes induced the re-establishment of ovarian cyclicity within 14 days. (author). 11 refs, 7 tabs.
1989-02-20
Failure of monsoon this year has been linked to the El Nino effect. What is this phenomenon
Energy Technology Data Exchange (ETDEWEB)
There are two major water currents off the coast of Peru in South America. The Humboldt or Peru current travels northwest across latitudes 35/sup 0/S to 6/sup 0/S. To the north, a branch of the equatorial current flows southward down to latitudes 6-7/sup 0/S in normal years. Its warm, less salty water is poor in nutrients and cannot support fishery. In some years, this warm current extends much more southward, down to 12/sup 0/S. This has a catastrophic effect leading to a mass mortality of the anchovies and, in turn, of the guano birds and less production of farm crops. This phenomenon occurs around Christmas (summer in the southern hemisphere) and is, therefore, called El Nino. The main feature of El Nino is to change the sea surface temperature. An abnormal rise in sea surface temperature can give rise to odd air movements which can change the monsoons pattern, even at distant places, profoundly. In the past 26 years, when El Ninos have occurred, they coincided ...
1987-10-01
Evaluation of some lupin mutants under different irrigation intervals and nitrogen fertilizer levels
International Nuclear Information System (INIS)
This investigation was carried out during the two seasons of 1998/1999 and 1999/2000 at the experimental farm belonging to the plant research department, nuclear research center, atomic energy authority in Inshas to evaluate four lupin mutant lines (L_1, L_2, L_3 and L_4) along with their original mother varieties giza 1 and giza 2 under different levels and nitrogen fertilizer levels. The results indicated that seed yield/ plant and its effective components number and weight of pods/plant were significantly higher in all the mutant lines as compared to their parents either in the first or second seasons. Concerning the effect of irrigation intervals on yield and its components for developed mutants and their mother varieties as well as the results gave an evidence that the wider interval showed the lesser values for yield and most of yield components. Obtained data also revealed that yield attributes of lupin mutants and their parents were affected by applying ...
2002-04-01
British Library Electronic Table of Contents (United Kingdom)
A field experiment was conducted during 2004 and 2005 at the research farm of Central Institute of Medicinal And Aromatic Plants, Lucknow located at 26.5^o N 80.5^o E and 120m above the mean sea level to study the effect of harvesting stage and cutting height on growth, yield and quality of Indian basil. The objective of this study was to increase the essential oil yield of Indian basil without adverse effect on quality by taking two harvests through manipulating harvesting stage and cutting height and to increase the land and rain water utilization efficiency under rain fed condition. The treatments consisted of four stages of first harvest (40, 60, 80 and 100 days after transplanting (DAT)) and three cutting height (0, 7.5 and 15.0cm above ground level). The Indian basil (Ocimum basilicu...
2010-01-01
Economical evaluation of electricity generation considering externalities
International Nuclear Information System (INIS)
The economics of renewable energy are the largest barrier to renewable penetration. Nevertheless, the strong desire to reduce environmental emissions is considered a great support for renewable energy sources. In this paper, a full analysis for the cost of the kWh of electricity generated from different systems actually used in Egypt is presented. Also renewable energy systems are proposed and their costs are analyzed. The analysis considers the external cost of emissions from different generating systems. A proposed large scale PV plant of 3.3 MW, and a wind farm 11.25 MW grid connected at different sites are investigated. A life cycle cost analysis for each system was performed using the present value criterion. The comparison results showed that wind energy generation has the lowest cost, followed by a combined cycle-natural gas fired system. A photovoltaic system still uses comparatively expensive technology for electricity generation; even when external costs ...
2002-02-01
Biomass research program of the USDA Southern Agricultural Energy Center
Energy Technology Data Exchange (ETDEWEB)
The biomass research program of the USDA, Southern Agricultural Energy Center is conducted at several locations throughout the United States. A portion of the research is directed toward improved systems to harvest, process and store biomass so that the energy density will be enhanced. Other research projects deal with: conversion and utilization of animal wastes in integrated energy-food production systems, including the production of liquid fuel and feed byproducts; producing low BTU gas to be utilized in internal combustion engines, including the system for continuous feeding of the gasifier; direct combustion of biomass for thermal energy; gasifying biomass so that the products of combustion can pass through a crop being dried without leaving deleterious residues; small scale systems for on-farm expelling of vegetable oil; and studies on the use of vegetable oils for diesel fuel substitutes. In summary, the low energy density of biomass requires that it be used ...
1982-08-01
Biodrying of animal slaughterhouse residues and heat production
Energy Technology Data Exchange (ETDEWEB)
Animal carcasses from slaughterhouses are usually composted on farms, but the composting process is not optimized and a large volumes of carbonaceous residues are needed. This type of composting takes place over a period of 6 to 9 months in a nonaerated static pile. Quebec's industrial research centre (CRIQ) developed an organic biodrying process (BIOSECO) adapted to large-scale operations in order to optimize the treatment of slaughterhouse residues. Biodrying is a form of composting, in which the thermophilic phase is optimized, making it possible to evaporate large amounts of water. Biodrying is done inside a building and reduces the amount of carbonaceous residues considerably. The process is optimized by the sequence in which the slaughterhouse residues are added, the choice of input and the aeration flow. Slaughterhouse residues can be treated non-stop throughout the entire year. Since the odours are nearly completed limited to the building, the ...
2010-07-01
Anaerobic digestion and related best management practices : utilizing life cycle assessment
Energy Technology Data Exchange (ETDEWEB)
This paper reported on a life cycle assessment (LCA) study that compared the environmental impacts of business-as-usual manure management with those of a manure management operation incorporating anaerobic digestion with combined heat and power generation. The case study was based on a medium sized dairy farm in northern New York State. The study identified the benefits resulting from the displacement of fossil fuels, and reduction of related emissions. Although anaerobic digestion of dairy manure with energy recovery through biogas combustion is viewed as a positive environmental approach to increase the use of renewable energy, there are potential negative impacts that can counteract the environmental benefits. The negative impacts are associated with emissions of methane and nitrogen species during digestion and after spreading of digester effluent. The environmental impacts and their causes should be evaluated in order to promote best management practices. ...
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this research was to examine the energy equivalents of inputs and output in greenhouse vegetable production in the Antalya province of Turkey. For this purpose, the data for the production of four greenhouse crops (tomato, cucumber, eggplant and pepper) were collected in eighty-eight greenhouse farms by questionnaire. The results revealed that cucumber production was the most energy intensive of among the four crops investigated. Cucumber production consumed a total of 134.77 GJha{sup -1} followed by tomato with 127.32 GJha{sup -1}. The consumption of energy by eggplants and pepper were 98.68 and 80.25 GJha{sup -1}, respectively. The output-input energy ratio for greenhouse tomato, pepper, cucumber and eggplant were estimated to be 1.26, 0.99, 0.76 and 0.61, respectively. This indicated an intensive use of inputs in greenhouse vegetable production not accompanied by increase in the final product. This can lead to problems associated with these inputs ...
2004-01-01
An anthropological view of the forest culture of Peten, Guatemala
Energy Technology Data Exchange (ETDEWEB)
Traditional farmers and harvesters of non-timber forest products in Peten treat the forest in ways that conserve and regenerate its resources. They believe no one owns the forest outright. Humans share it with other life forms and therefore no one has the right to monopolize or destroy forest resources. Traditional Peteneros find a use for almost everything in the forest, and believe it neither smart nor proper to use a given area for a single purpose, for example, to clear an area of all trees and devote it exclusively to a cattle pasture. In the traditional system most medicinal plants, basic foodstuffs, fuelwoods and construction materials are taken from the bosque (secondary forests within walking distance of human settlements). Peteneros` sustainable use of bosques eases pressure on the monte (primary forests). In the monte Peteneros` harvesting practices are protective of resources, causing minimal damage. Finding almost everything in the forest useful, Peteneros believe all ...
1995-12-31
[Legionella pneumonia caused by aspiration of hot spring water after sarin exposure].
A 72-year-old man was exposed to the sarin gas attack in a Tokyo subway on March 20 th, 1995. After exposure, he noticed eye discomfort, chest tightness, headache and weakness of the lower limbs and oropharyngeal muscles. Despite these symptoms, he visited a hot spring on the same day with his family. On March 25 th, his muscle weakness progressed, and a low grade fever appeared. His muscle weakness disappeared 8 days after exposure to sarin, but respiratory failure rapidly developed, necessitating artificial ventilation within four day after hospitalization on March 28th. Chemotherapy with erythromycin, imipenem/cilastatin, and steroid pulse therapy was begu. PCR and culture of sputum collected by bronchofiberscopy were positive for Legionella pneumophila, serogroup I. His respiratory state improved, but subsequent infection with Pseudomonous aeruginosa. Enterobacter cloacae, and Candida tropicalis/glabrata caused his death 71 days after admission. Oropharyngeal ...
1998-03-01
Energy Technology Data Exchange (ETDEWEB)
From long-term real-time radon and radon progeny measurements taken in a relatively large retail store, cyclical patterns were evident, which were found to relate to the overriding influence of the timed air-conditioning system. Concentration of radon, radon progeny and the variability of F factor were found to depend significantly on the intermittent operation of this ventilation-air-conditioning system. After pressure equalisation remedial measures proved ineffective, the air-movement system was utilised to reduce the levels of radon and radon progeny to well within established norms applicable during working hours. It is demonstrated that the average levels for radon and radon progeny are reduced in absolute terms. This amounted to less than 12% of the general level, during designated work periods. Where air movement systems are already installed, as well as other circumstances, their regulation provides an economical solution to meeting legal and other ...
2000-07-01
Energy Technology Data Exchange (ETDEWEB)
Vaarst Vestervang (Denmark) comprises 16 villas and 1 communal building. The complex was designed by the inhabitants themselves with the aim of polluting the environment as little as possible. The land area constitutes 69.000 square meters where it is possible to grass animals. The document reports a measuring programme concerning the overall heat consumption as one of the main aims of the inhabitants is to save energy and thus contribute to the protection of the environment. The capacity of the solar collectors predominantly used in the building complex was 235 kWh/m{sup 2}. Supplementary heating is provided by boilers fired with wood. The measuring system is described in detail. Tables show the influence of heat transmission losses, ventilation, airing out of rooms, the angle of the sun`s rays within the buildings and heating needs on energy consumption. Energy consumption data is presented in relation to the forms of space and water heating utilized. Daily ...
1993-10-01
Energy Technology Data Exchange (ETDEWEB)
The German voluntary standard 'Passivhaus' (passive house) leads to buildings with practically no energy consumption. The first residential buildings of this type were built in 1998 and the first tertiary buildings in 2000. Such a passive house must fulfill 5 efficiency criteria: annual space heating needs {<=} 15 kWh/m{sup 2}, U{sub v} envelope coefficient lower than 0.15 W/(m{sup 2}.K), U{sub v} of openings lower than 0.8 W/(m{sup 2}.K), airtightness {<=} 0.6 volume/hour, and total energy needs (space heating, hot water, ventilation, lighting and domestic uses) measured at the meter lower than 42 kWh/m{sup 2}.year. This article makes a status of the effective efficiency of existing passive buildings both in the residential and tertiary sectors and presents some possible ways of improvement. (J.S.)
2005-10-01
Series fan-powered boxes: Their impact on indoor air quality and comfort
Energy Technology Data Exchange (ETDEWEB)
Until the concerns about indoor air quality (IAQ) reached a peak in the last five years, interior zones of office buildings were traditionally served with cooling-only shut-off variable air volume (VAV) boxes. Heat gains from lighting and equipment, in addition to those from occupants themselves, caused supply air quantities of 13 C to 15 C (55 F to 60 F) air to be sustained at rates on the order of 2.5 L/s per square meter (0.5 cfm per square feet), a rate that most designers at the time felt would provide a comfortable and well ventilated environment. More recently, the reduction in lighting loads, the use of cold air systems, and, most importantly, the concern that acceptable indoor air quality may not be maintained at low air flow rates, has led to a different solution in interior zones: the series fan-powered mixing box.
1996-07-01
Reducing indoor air formaldehyde concentrations
Energy Technology Data Exchange (ETDEWEB)
Urea-formaldehyde resin bonded particle board, medium density fiberboard and plywood paneling are used as flooring, wall paneling, for cabinet work and in furniture, and are present in almost every office, home and public building. If large quantities of these products are used in poorly ventilated spaces, high manufacturing quality control is necessary to avoid problems of latent formaldehyde release. Indoor air formaldehyde concentrations depend on the nature of the product, the product surface to air volume (loading) factor, temperature, humidity, age and product emission rates. Standard test methods are now available for measuring product emission rates that make it possible to predict the performance of UF-bonded pressed wood materials if use conditions and environmental parameters are known. Recent modifications in adhesive and board manufacturing parameters have made it possible to reduce formaldehyde emission significantly, and UF-bonded wood products are ...
1985-08-01
Radon concentration measurements in the desert caves of Saudi Arabia
Energy Technology Data Exchange (ETDEWEB)
Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm{sup -3}. The average radon concentration in four of the caves was low in the range 74-114Bqm{sup -3}. However, one cave showed an average radon concentration of 451Bqm{sup -3}. Radon is not a problem for tourists in the ...
2005-11-15
Radon concentration measurements in the desert caves of Saudi Arabia
International Nuclear Information System (INIS)
Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm"-"3. The average radon concentration in four of the caves was low in the range 74-114Bqm"-"3. However, one cave showed an average radon concentration of 451Bqm"-"3. Radon is not a problem for tourists in the majority of ...
2005-11-01
Energy Technology Data Exchange (ETDEWEB)
Airborne pollutants can cause failures in switching and computing equipment. This paper focuses on a subset of such pollutants - airborne fine particles (<2.5 [mu]m diameter). It begins by examining the extent to which different improvements in heating, ventilating and air conditioning (HVAC) systems reduce indoor concentrations of fine particles. For each modification, the consequent reduction in soiling rate is derived. The concomitant increase in operating costs is also calculated. These costs are then compared with the costs of failures in telephone switching offices, leading to estimates of failure rate reductions that would make improvements cost-effective. Finally, the reduction in failures required to offset the costs of the improvements are compared with documented differences in failure rates between unimproved and improved environments. This study suggests that, in many telephone switching offices, the added operating costs associated with more ...
1991-01-01
Overview of Chuetsu-oki earthquake and evaluation of seismic safety
International Nuclear Information System (INIS)
The Chuetsu-oki Earthquake strongly shook the Kashiwazaki-Kariwa Nuclear Power Station with the ground motions exceeding the design values. The incidents include a fire breakout of the Unit 3 transformer, a release of spilled water containing small amount of radioactive materials to the non-radiation control area and subsequently to the environment at Unit 6, and a release of radioactive material from the main turbine condenser through the main stack of Unit 7 due to the delay stooping the turbine gland steam ventilator by the operator in manually, while every unit in operation was safety shutdown in the automatic mode ensuring the three fundamental safety functions of (a) reactivity control, (b) removal of heat from the core and (c) confinement of radioactive materials. Following integrity evaluation and performance testing of the overall plant, seismic safety of buildings, structures, equipment and pipelines on the basis of the basic earthquake ground motion Ss ...
2010-07-01
In-depth survey report of Early and Daniel Co. , Inc. , Louisville, Kentucky
An in-depth industrial hygiene survey was conducted to evaluate worker exposures to phosphine during fumigation of grain at the Early and Daniel Co. grain elevator in Louisville, Kentucky. Stored grain was fumigated using aluminum phosphide. Aluminum-phosphide pellets were also added directly to the grain by the blender as it was poured into the storage containers. Local exhaust ventilation was used at points in the grain-moving system where grain dust was generated. Air samples were taken during full-shift periods at the breathing zone of the weighmaster, two bin floormen, and the blender. Area monitoring samples were also taken. If the operators spend considerable time in the vicinity of a bin which is being filled with grain, there is a likelihood of far greater exposure levels being noted. According to the author, further studies of the use of phosphide products at other elevators should be conducted to determine the effect of environmental and process ...
1986-09-01
Guidelines for indoor air hygiene in school buildings
Energy Technology Data Exchange (ETDEWEB)
The new guidelines for indoor air hygiene in school buildings are intended as a response to current requirements in school practice. The recommendations aim to help to avoid mistakes in modernising school buildings and to provide hygiene-specific support in planning of new school buildings. The guidelines are laid out as follows: (a) In the general section the targets of the guidelines and the target groups are addressed. The current indoor hygiene situation in German schools is described, followed by the parameters with regard to peripheral issues which will not be dealt with further; (b) Part A deals with the hygiene requirements in the practical running of schools. Besides general requirements for maintenance and operation the important issues of cleaning and ventilation are considered, as well as minor building works; (c) Part B provides an overview of important chemical and biological contaminants in schools; (d) Part C looks at building and air conditioning ...
2008-08-15
This report describes the result of work completed during February, 1982 to October 1983. The aim of the work was to develop a low NO(x) emission range top burner. Discussed is the development of a flame insert modification to an existing burner which reduces NO(x) emission by 45 percent and NO2 emission by 25 percent. This relatively simple burner add-on device appears to be an economically viable low NO(x) burner. It was developed in cooperation with a major range manufacturer. The levels of NO(x) (NO2) reduction achieved should significantly reduce the impact of a gas range to indoor quality. The report also discusses the results of a literature search that preceeded the burner development. The search helped to direct the burner development by reviewing the state-of-the-art of low NO(x) burner design and covered factors which affect the indoor impact of range emissions such as air infiltration and ventilation trends, air quality standards, and NO(x) (NO2) health ...
1983-11-01
This report describes the results of work conducted during February 1982 - January 1983. A literature search was initiated to identify the state-of-the-art of NOx (NO + NO/sub 2/) reduction technologies, including NOx measurement methodologies, air infiltration and ventilation trends, the impact of NOx (NO/sub 2/) emissions on health, and air quality standards. As a result of the literature search NOx (NO/sub 2/) reduction goals were established for the project and technologies to achieve these goals identified. This report also covers the development of a prototype burner which examined flue gas recirculation, burner designs, secondary air baffling and flame inserts as potential technologies to reduce NOx (NO/sub 2/). Because of their potential for NOx (NO/sub 2/) reduction shown by initial experiments, an in-depth analysis of ring insert configurations was conducted. These results, along with other technological experiments, are presented in this report.
1983-02-28
Energy Technology Data Exchange (ETDEWEB)
A survey to assess the techniques used to control occupational exposure to formaldehyde (50000) and methanol (67561) was conducted at the E. I. DuPont de Nemours and Company (SIC-2869) formaldehyde production unit, Linden, New Jersey, in October 1982. Exposure concentrations were reduced primarily by the use of a process that was completely enclosed except for process sampling, methanol unloading, and formaldehyde discharge points. Local and area exhaust ventilation, and work practices were also used to control exposures. Formaldehyde concentrations in the absorber area were controlled by burning the exit gases in an afterburner and discharging them high above the ground. Analysis of area and breathing zone samples showed methanol and formaldehyde concentrations below the OSHA limits of 200 and 3 parts per million, respectively. The authors conclude that workers are not overexposed to either methanol or formaldehyde on a short or long term basis. Maintenance ...
1983-09-01
Design and analysis of a dust extraction system
Energy Technology Data Exchange (ETDEWEB)
A dust extraction system removes the contaminated air at source by means of a hood. The extraction system for dust is essentially a ducted air system that prevents excessive employee exposure to dust in the working zone. The four major mechanisms that remove the contaminants in an extraction system are: - capture of contaminants by hoods - transport of contaminated air in duct network - separation of dust in the collector - exhaust of clean air through stack. The current methods of design are based on empirical relations, multi-variable tables, graphs and nomographs that have been derived from the principle of fluid mechanics and particle dynamics. However, the empirical formulae, tables and graphs are used in different geographical locations of the world having different environmental conditions and geo-characteristics of dust particles. Therefore, it is required to establish a rational design method that will be based on analysis of each sub-system to achieve an efficient and cost ...
2006-07-01
Control of population dose equivalent from naturally occurring radionuclides in building materials
International Nuclear Information System (INIS)
Naturally occurring radionuclides in building materials are a source of external and interal radiation exposure to essentially the entire US population. Although detailed data are not available, estimates are that the average contribution from such sources to the external dose equilvaent rate in brick and masonry houses is about 5 to 10 mrem/year. For critical population groups, values reported in the literature for the contribution from such sources range up to a hundred mrem/year or more. Dose equivalent rates to the lungs are even higher and, for abnormal situations, it would appear that control measures, either on a voluntary or mandatory (legislative) basis should be considered. Such measures include: (1) material substitution; (2) improved manufacturing standards; (3) changes in basic building designs; (4) application of surface sealants; and (5) increased ventilation accompanied by processes for the adsorption and/or filtration of airborne radionuclides. ...
Control of airborne particle concentration and draught risk in an operating room
Energy Technology Data Exchange (ETDEWEB)
The influence of location of airborne particle source, ventilation rate, air inlet size, supply air velocity, air outlet location, and heat source on the distributions of airborne particle concentration and draught risk in an operating room is investigated. The investigation is carried out by using a flow program with the k-[epsilon] model of turbulence. Based on a standard case, five cases, each with one changed parameter, are computed, and the detailed field distributions of air velocity, temperature, airborne particle concentration, and draught risk are presented. The parametric study concludes that, for a better air quality and thermal comfort, it is desirable to use a higher inflow rate, a larger inlet area, and a uniform velocity profile of supply air. Outlet location and heat source have little influence on the distributions of the particle concentration in the room. It has also been found that the distributions of particle concentration in the recirculating ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
This report describes the combustion experiments performed using the SP Industry Calorimeter. In addition to measuring parameters such as heat release rate (HRR), mass loss rate, effective heat of combustion and smoke obscuration, considerable effort was put into the characterisation of the smoke gases in order to obtain a basis for evaluations of the toxic potency of the smoke. The materials studied were Nylon 66, polypropene, polystyrene (with and without fire retardant, respectively), PVC and chlorobenzene. A total of 19 large-scale, well ventilated combustions were carried out. The mass of sample burned ranged from 20 kg to 125 kg in an experiment. A procedure was designed for cleaning the smoke gas duct between experiments and was found to be effective. Measurements were carried out for the amounts of O{sub 2}, CO{sub 2}, CO, NO{sub x}, THC (unburned hydrocarbons), HCN, HCl, NH{sub 3} and individual organic compounds in the smoke. Adsorbents were used for the ...
1995-12-31
Climate analysis of the Dresden Frauenkirche; Bauklimatische Analyse der Frauenkirche in Dresden
Energy Technology Data Exchange (ETDEWEB)
The analyses were carried out using real climate data for the years 1987 and 1989. The course of the indoor climate for year-round free ventilation with a constant flow volume is discussed. Numerous diagrams inform on ambient temperature, water vapour content, the condition of space air, and temperature drops below dew point. For the event of heating of the central part of the church, space air condition, the annual air humidification requirement, and the temperature field in this part of the building are described. (MSK) [Deutsch] Die Untersuchungen wurden mit aktuellen Klimadaten fuer die Jahre 1987 und 1989 durchgefuehrt. Der Verlauf des Raumklimas bei ganzjaehrig freier Klimatisierung mit konstantem Foerderstrom wird erlaeutert. Dabei wird die Raumlufttemperatur, der Wasserdampfgehalt, der Raumluftzustand sowie die Taupunktunterschreitung in zahlreichen Diagrammen aufgezeigt. Weiter werden fuer den Fall der Beheizung des Hauptraums der Kirche der ...
1997-12-01
Energy Technology Data Exchange (ETDEWEB)
Zone modeling permits taking account of the effect of load-relieving air conduction systems in the planning of HVAC plants. Although this only supplies average values for the degree of load and height of the fresh air layer rather than a detailed description of concentration and temperature distributions in the room, it is quite sufficient for the planning of load-relieving air conduction systems. Moreover, the cost of zone modeling in the planning of HVAC plants remains within reasonable limits. Upscale planning, instruments can thus be reserved for more exacting problems. (orig.) [Deutsch] Zonenmodelle erlauben die Wirkung lastmindernder Luftfuehrungen bei der Planung von RLT-Anlagen zu beruecksichtigen. Sie liefern zwar nur Mittelwerte fuer den Belastungsgrad und die Hoehe der Zuluftschicht und keine detaillierte Konzentrations- und Temperaturverteilungen im Raum. Diese Werte reichen jedoch fuer die Planung lastmindernder Luftfuehrungskonzepte aus. Zudem ist der Aufwand fuer den ...
1994-12-31
CFD investigation of unstable airflow due to temperature difference via horizontal openings
Energy Technology Data Exchange (ETDEWEB)
Air flow and the buoyancy-driven flow through a building`s horizontal openings was discussed. Horizontal openings occur in staircases, stairwells, ventilation shafts and chimneys. Mass and energy transfer through them have important implications regarding energy saving, thermal comfort, control of contaminants and micro-organisms and spread of fire and smoke. The analysis of the buoyancy-driven flow was attained using computational fluid dynamics (CFD). Use was made of the CFD code FLUENT which integrated the Navier-Stokes equations by a time-dependent, finite volume method. Good agreement was achieved between predicted and experimental measurements of flow rate. Results showed that flow patterns in horizontal openings were transient and unstable. The air exchange through the openings occurred in intermittent pulses. The flow rate through the opening increased with the temperature difference between zones in buildings and the size of the horizontal opening. 3 ...
1995-12-31
Aerodynamic design of the George Washington University solar car Sunforce 1
Energy Technology Data Exchange (ETDEWEB)
Aerodynamics play a critical role in the success of a competitive solar vehicle. In particular, the topics addressed in this paper are minimizing the drag forces acting on the car surface while providing an effective angle of solar exposure, ventilation, manoeuvring stability, maintenance accessibility, and component `functional duality`, while simultaneously maintaining stringent racing regulations. Starting with a conceptual design, modifications were analysed through a commercial, computational fluid dynamics (CFD) package in order to evaluate drag and lift characteristics. By visualizing wind tunnel flow as a means of support of the coded model, the computational design has been validated. Although the design of the George Washington University (GWU) solar car `Sunforce 1` was geared towards the November 1993 World Solar Challenge held in Australia, results of the fourth place finish in the US Sunrace `93 were used to demonstrate the effectiveness of this ...
1997-05-01
Abrasive waterjet cutting of high purity uranium metal: Topical report
The Abrasive Waterjet Cutting process was evaluated to determine if the equivalent could be utilized for cutting uranium metal at the Feed Materials Production Center (FMPC). In the process, a thin stream of ultrahigh pressure water carried grit material through a designated piecepart. In order to be acceptable for use at the FMPC, the equipment must be cost effective, minimize waste, and be adaptableto operating in an enclosure, and improve health and safety conditions. Observation of the cutting process showed that health and safety aspects could be optimized with an enclosed ventilated system. Also the equipment can be easily automated. The cutting action produced sparks similar to the sparks caused by a grinding operation. The sparks are captured in a water container under the workpiece that not only catches the sparks, but also serves to dissipiate the stream of water and residues produced by the cut. Metallographic tests performed on the cut surface of the ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
In the first part of the nineties many office buildings were equipped with indoor climate installations which do not meet present standards. Several options are available to improve such installations for ventilation capacity, cooling capacity, thermal comfort and air quality. One of the options concern the installation of an air conditioner in combination with heat recovery. In this article attention is paid to the renovation of the air conditioning system in the Printer house, an office building in Zwolle, Netherlands. [Dutch] Begin jaren negentig zijn veel kantoorpanden gebouwd waarvan de klimaatinstallatie tegenwoordig niet meer voldoet. De ventilatiecapaciteit is ontoereikend en koeling is mondjesmaat aanwezig, of slechts als topkoeling. Het comfort en de luchtkwaliteit zijn dan ook onder de maat. Er zijn verschillende mogelijkheden om dit te verbeteren. Plaatsing van een nieuwe luchtbehandelingskast met warmteterugwinning is daar een van. In dit artikel wordt ...
2007-05-15
Power control for wind turbines in weak grids: Concepts development
Energy Technology Data Exchange (ETDEWEB)
Presently, high wind potentials in remote areas may not be utilized for electricity production due to limited grid transmission capacity and/or difficulties in matching the electricity production with the demand. The overall project objective is to help overcome these bottlenecks, i.e. to identify and analyze methods and technologies for making it viable to utilize more of the wind potential in remote areas. The suggestion is to develop a power control concept for wind turbines which will even out the power fluctuations and make it possible to increase the wind energy penetration. The main options are to combine wind power with a pumped hydro power storage or with an AC/DC converter and battery storage. The AC/DC converter can either be an `add-on` type or it can be designed as an integrated part of a variable speed wind turbine. The idea is that combining wind power with the power control concept will make wind power more firm and possible to connect to weaker grids. So, when the ...
1999-03-01
Ozone removal by green building materials
Energy Technology Data Exchange (ETDEWEB)
Interest in finding out passive ways to keep the variation in the indoor climate within the comfort zone is gaining in popularity. One possible solution is the use of the moisture-buffering property of materials. In this study, the effects of the ventilation system and moisture-buffering properties of the building fabric on the stability of the indoor temperature and humidity are analysed by means of long-term field measurements. Indoor climate measurements were carried out in 170 detached houses (248 rooms). Temperature and relative humidity were measured continuously in bedrooms and living rooms at one-hour intervals over a one-year period. In general, it may be concluded that in this study, the ventilation had a greater effect on the indoor climate than the properties of the building fabric. The dampening effect of hygroscopic materials was remarkably less in the field measurements than it was in simulations in different studies. This ...
2009-08-15
Indoor radon concentration measurements in Tarqumia Girl Schools at Western Hebron Region, Palestine
International Nuclear Information System (INIS)
In this study, radon-222 in indoor air was surveyed in 62 rooms located in four governmental schools, for girls, in Tarqumia town that lies in the north western part of Hebron city in Palestine. The annual effective dose equivalents resulting from the inhalation of radon and its daughters by 2318 pupils and 102 staff members occupying the surveyed rooms were also measured. TASTRAK, a solid state nuclear track detector, has been used to measure the indoor radon concentrations at those schools thus, 124 radon detectors were distributed in the four school buildings. The radon detectors stayed for 70 days between February 2006 and April 2006. The results showed that the radon concentration and the annual effective dose equivalent in these schools were varied from 12 to 232.5 Bq/m"3 with an average of 34.1 Bq/m"3 and 0.62 to 12.0 mSv/y with an average of 1.76 mSv/y, respectively. The mean values of radon concentrations in Tarqumia secondary girls school, Al-aqsa elementary girls school, ...
FDS3 simulations of indoor hydrocarbon fires engulfing radioactive waste packages
International Nuclear Information System (INIS)
The thermal environment of a hypothetical large indoor hydrocarbon pool fire is more complex compared to outdoor fires and can be more severe for engulfed objects. In order to analyze potential thermal environments for interim storage of spent fuel casks or low-level radioactive waste packages engulfed in pool fires numerical simulations with the CFD fire code FDS3 were carried out for different storage configurations. In addition, data of indoor pool fire experiments were used to validate the model for this type of application. A series of pool fire experiments under different ventilation conditions and varied pool surface (1 m"2 - 4 m"2) inside a compartment of 3.6 m x 3.6 m x 5.7 m was conducted at iBMB (Institut fuer Baustoffe, Massivbau und Brandschutz) of Braunschweig University of Technology, Germany. The instrumentation included thermocouples, heatflux and pressure gauges, bi-directional flow probes and gas concentration measurements. A mock low-level waste ...
2004-09-20
UNSAT-H Version 3.0: Unsaturated Soil Water and Heat Flow Model Theory, User Manual, and Examples
Energy Technology Data Exchange (ETDEWEB)
The UNSAT-H model was developed at Pacific Northwest National Laboratory (PNNL) to assess the water dynamics of arid sites and, in particular, estimate recharge fluxes for scenarios pertinent to waste disposal facilities. During the last 4 years, the UNSAT-H model received support from the Immobilized Waste Program (IWP) of the Hanford Site's River Protection Project. This program is designing and assessing the performance of on-site disposal facilities to receive radioactive wastes that are currently stored in single- and double-shell tanks at the Hanford Site (LMHC 1999). The IWP is interested in estimates of recharge rates for current conditions and long-term scenarios involving the vadose zone disposal of tank wastes. Simulation modeling with UNSAT-H is one of the methods being used to provide those estimates (e.g., Rockhold et al. 1995; Fayer et al. 1999). To achieve the above goals for assessing water dynamics and estimating ...
2000-06-12
Energy Technology Data Exchange (ETDEWEB)
The subcriticality of two interacting solution tanks was determined using /sup 252/Cf-source-driven neutron noise analysis methods. These experiments were the first test of this method for an interacting system with materials (in this case, uranyl nitrate) typical of nuclear materials in processing plants. The experiments were performed to test the conclusions from previous interaction experiments with uranium metal discs for a fissile system with moderation, and to provide data to test theoretical models for coupled systems. The uranium metal experiments showed that the subcritical neutron multiplication factor, k/sub eff/, could be determined using point kinetics without any correction for spatial effects from measurements with the source and detectors located adjacent to the same cylinder, whereas for source-detector configurations with either the source and/or detectors adjacent to different cylinders, a model which incorporates the coupling is required to ...
1986-01-01
Radiation testing of organic ion exchange resins
Energy Technology Data Exchange (ETDEWEB)
A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated ...
1995-09-01
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the major activities conducted in the Chemical and Energy Research Section of the Chemical Technology Division at Oak Ridge National Laboratory (ORNL) during the period October--December 1997. The section conducts basic and applied research and development in chemical engineering, applied chemistry, and bioprocessing, with an emphasis on energy-driven technologies and advanced chemical separations for nuclear and waste applications. The report describes the various tasks performed within six major areas of research: Hot Cell Operations, Process Chemistry and Thermodynamics, Separations and Materials Synthesis, Fluid Structure and Properties, Biotechnology Research, and Molecular Studies. The name of a technical contact is included with each task described, and readers are encouraged to contact these individuals if they need additional information. Activities conducted within the area of Hot Cell Operations included efforts to optimize the processing conditions ...
1999-02-01
Quantifying the Reactive Uptake of OH by Organic Aerosols in aContinuous Flow Stirred Tank Reactor
Energy Technology Data Exchange (ETDEWEB)
Here we report a new method for measuring the heterogeneous chemistry of submicron organic aerosol particles using a continuous flow stirred tank reactor. This approach is designed to quantify the real time heterogeneous kinetics, using a relative rate method, under conditions of low oxidant concentration and long reaction times that more closely mimic the real atmosphere. A general analytical expression, which couples the aerosol chemistry with the flow dynamics in the chamber is developed and applied to the heterogeneous oxidation of squalane particles by hydroxyl radicals (OH) in the presence of O2. The particle phase reaction is monitored via photoionization aerosol mass spectrometry and yields a reactive uptake coefficient of 0.51+-0.10, using OH concentrations of 1-7x108 molec cdot cm-3 and reaction times of 1.5+-3 hours. This uptake coefficient is larger than that found for the reaction carried out under high OH concentrations (~;;1x1010 molec cdot cm-3) and ...
2009-03-01
Energy Technology Data Exchange (ETDEWEB)
A method for determining the reactivity of highly subcritical systems of fissile material, using neutron-noise power spectral densities in conjunction with a /sup 252/Cf source, had previousy been tested in two fast reactor critical assemblies (a mockup of the Fast Flux Test Facility reactor and unreflected enriched uranium metal assemblies) and one thermal reactor (a light-water moderated and reflected lattice of Oak Ridge Research Reactor fuel elements). The last-mentioned test demonstrated the effectiveness of the method in water-moderated systems and thereby prompted the present study of its application to facilities for fuel preparation, reprocessing, and storage. To investigate the applicability of this method to facilities for fuel preparation, reprocessing, and storage, limited experiments were performed with a uranyl fluoride solution. The Los Alamos National Laboratory SHEBA facility, an unreflected cylindrical tank (56 cm diam), was partially filled with ...
1981-01-01
Performance objectives for the Hanford immobilized low-activity waste (ILAW) performance assessment
Energy Technology Data Exchange (ETDEWEB)
Before low-level waste may be disposed of, a performance assessment must be written and then approved by the DOE (DOE 1988a DOE 1999a). The performance assessment is to determine whether ''reasonable assurance'' exists that the performance objectives of the disposal facility will be met. The DOE requirements for waste disposal (DOE 1988a DOE 1999a) require the protection of public health and safety; and the protection of the environment. Although quantitative limits are sometimes stated (for example, the all-pathways exposure limit is 25 mrem/year), usually the requirements are stated in a general nature. Quantitative limits were established by: investigating all potentially applicable regulations as well as interpretations of the review panels which DOE has established to review performance assessments, interacting with program management to establish the additional requirements of the program, and interacting with the public (i.e., the Hanford ...
1999-09-09
International Nuclear Information System (INIS)
To demonstrate that the caustic-side solvent extraction (CSSX) process could remove cesium from Savannah River Site (SRS) high-level waste over long periods of time, an improved minicontactor (2-cm centrifugal contactor) was needed that could be operated for several days. In particular, the contractor temperature had to be controlled and contactor hydraulic performance needed to be improved. Because the process was to be continuous, provisions were made for a three-shift operation. With the improvements made and the operators trained, the CSSX process was run in a 33-stage minicontactor over a period of three days to remove cesium from an average SRS siumulant for the waste feed. The two key process goals were achieved: (1) the cesium was removed from the waste with decontamination factors greater than 40,000 and (2) the recovered cesium was concentrated by a factor of 15 in dilute nitric acid. These goals were maintained for 71 h as 1.4 L of solvent was recycled 42 times while ...
Development of a dedicated ethanol ultra-low emission vehicle (ULEV) system design
Energy Technology Data Exchange (ETDEWEB)
The objective of this 3.5 year project is to develop a commercially competitive vehicle powered by ethanol (or ethanol blend) that can meet California`s ultra-low emission vehicle (ULEV) standards and equivalent corporate average fuel economy (CAFE) energy efficiency for a light-duty passenger car application. The definition of commercially competitive is independent of fuel cost, but does include technical requirements for competitive power, performance, refueling times, vehicle range, driveability, fuel handling safety, and overall emissions performance. This report summarizes a system design study completed after six months of effort on this project. The design study resulted in recommendations for ethanol-fuel blends that shall be tested for engine low-temperature cold-start performance and other criteria. The study also describes three changes to the engine, and two other changes to the vehicle to improve low-temperature starting, efficiency, and emissions. The three engine ...
1995-02-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
