WorldWideScience
1

Corrosion 2003. Conference papers on CD-ROM  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented under 38 symposia. Subjects included reinforced concrete, protective coatings and linings, cathodic/anodic protection, chemical cleaning of boilers, managing corrosion with plastics, water treatment, HRSG boiler tube failure analysis, corrosion in oil and gas production, corrosion in petroleum refining and gas, processing, pipelines and tanks, high temperature materials, chemical process industry, aerospace equipment, materials technology developments for incinerators and waste fuel-fired processors, materials and corrosion in fossil-fuels conversion and combustion, corrosion in nuclear systems, marine corrosion, building systems, corrosion mechanisms, corrosion inhibitors and corrosion monitoring and measurement.

2003-07-01

2

Absorption of carbon dioxide in waste tanks  

International Nuclear Information System (INIS)

Air flow rates and carbon dioxide concentrations of air entering and exiting eight H-Area waste tanks were monitored for a period of one year. The average instanteous concentration of carbon dioxide in air is within the range reported offsite, and therefore is not affect by operation of the coal-fired power plant adjacent to the tank farm. Waste solutions in each of the tanks were observed to be continuously absorbing carbon dioxide. The rate of absorption of carbon dioxide decreased linearly with the pH of the solution. Personnel exposure associated with the routine sampling and analysis of radioactive wastes stored at SRP to determine the levels of corrosion inhibitors in solution could be reduced by monitoring the absorption of carbon dioxide and using the relationship between pH and carbon dioxide absorption to determine the free hydroxide concentration in ...

1987-09-01

3

Some aspects of concentrated sulphuric acid storage tank corrosion  

Energy Technology Data Exchange (ETDEWEB)

Carbon steel is frequently used to construct concentrated sulphuric acid storage tanks. This paper discussed the corrosion performance of carbon steel tanks and outlined the underlying mechanisms responsible for major corrosion modes. Analyses of hydrogen grooving and dilute acid corrosion failure mechanisms were presented. Recent corrosion-induced leak failures were also discussed. The use of anodic protection and organic coatings as a corrosion control measure was also evaluated. The results of laboratory studies that were conducted to understand corrosion-induced failures showed that carbon steel electrodes exhibited transpassive corrosion at relatively high anodic potentials, while stainless steel electrodes exhibited transpassive corrosion at anodic potentials less than 1 V. ...

2009-07-01

4

Characterization of the corrosion behavior of the carbon steel liner in Hanford Site single-shell tanks  

Energy Technology Data Exchange (ETDEWEB)

Six safety initiatives have been identified for accelerating the resolution of waste tank safety issues and closure of unreviewed safety questions. Safety Initiative 5 is to reduce safety and environmental risk from tank leaks. Item d of Safety Initiative 5 is to complete corrosion studies of single-shell tanks to determine failure mechanisms and corrosion control options to minimize further degradation by June 1994. This report has been prepared to fulfill Safety Initiative 5, Item d. The corrosion mechanisms that apply to Hanford Site single-shell tanks are stress corrosion cracking, pitting/crevice corrosion, uniform corrosion, hydrogen embrittlement, and microbiologically influenced corrosion. The corrosion data relevant to the ...

1994-06-01

5

Performance evaluation of corrosion probes in simulated WVNS tank 8D-2 waste: WVNS tank farm process support  

Energy Technology Data Exchange (ETDEWEB)

Five corrosion probes were received from West Valley Nuclear Services for evaluation in simulated tank 8D-2 3rd-stage sludge wash slurry. The same waste slurry simulated was also used in a series of ongoing corrosion studies assessing the effects of in-tank sludge washing on the integrity of tank 8D-2. Two of the corrosion probes were installed in the coupon corrosion test vessels operating at {approximately}150{degrees}F to compare performance of the probes with that observed by coupon tests conducted in the same vessels. Corrosion rate data calculated from electrical resistance measurements of the corrosion probes were evaluated for this study using two slightly different approaches. One approach uses the total length of exposure of the probe to give a ``time-averaged`` value of the ...

1994-07-01

6

FIELD CORROSION TESTS IN REDOX AND PUREX UNDERGROUND WASTE STORAGE TANKS  

Science.gov (United States)

A corrosion-testing program has been initiated in Purex and Redox storage tnnks to obtain corrosion data on carbon steel and three associated materials in neutralized process wastes. (C.W.H.)

1955-06-28

7

Corrosion and failure processes in high-level waste tanks  

Energy Technology Data Exchange (ETDEWEB)

A large amount of radioactive waste has been stored safely at the Savannah River and Hanford sites over the past 46 years. The aim of this report is to review the experimental corrosion studies at Savannah River and Hanford with the intention of identifying the types and rates of corrosion encountered and indicate how these data contribute to tank failure predictions. The compositions of the High-Level Wastes, mild steels used in the construction of the waste tanks and degradation-modes particularly stress corrosion cracking and pitting are discussed. Current concerns at the Hanford Site are highlighted.

1992-11-01

8

Potential for erosion corrosion of SRS high level waste tanks  

Energy Technology Data Exchange (ETDEWEB)

SRS high-level radioactive waste tanks will not experience erosion corrosion to any significant degree during slurry pump operations. Erosion corrosion in carbon steel structures at reported pump discharge velocities is dominated by electrochemical (corrosion) processes. Interruption of those processes, as by the addition of corrosion inhibitors, sharply reduces the rate of metal loss from erosion corrosion. The well-inhibited SRS waste tanks have a near-zero general corrosion rate, and therefore will be essentially immune to erosion corrosion. The experimental data on carbon steel erosion corrosion most relevant to SRS operations was obtained at the Hanford Site on simulated Purex waste. A metal loss rate of 2.4 mils per year was measured at a temperature of 102 C and a slurry ...

1994-01-01

9

Corrosion: Understanding the basics  

Energy Technology Data Exchange (ETDEWEB)

This new book presents a practical how to approach to understanding and solving the problems of corrosion of structural materials. Although it is written mainly for those having a limited technical background in corrosion, it also provides more experienced engineers with a useful overview of the principles of corrosion and can be used as a general guide for developing a corrosion-control program. Contents include: the effects and economic impact of corrosion; basic concepts important to corrosion; principles of aqueous corrosion; forms of corrosion: recognition and prevention; types of corrosive environments; corrosion characteristics of structural materials; corrosion control by proper design; corrosion control by materials selection; ...

2000-07-01

10

ON-LINE MONITORING OF FLUE GAS DESULFURIZATION ...  

Science.gov (United States)

... Title : ON-LINE MONITORING OF FLUE GAS DESULFURIZATION SCRUBBER CORROSION WITH ELECTROCHEMICAL TECHNIQUES. ...

1986-11-01

11

Needs and opportunities for monitoring corrosion  

International Nuclear Information System (INIS)

Various electrochemical techniques are available to continuously monitor corrosion in conditions simulating those on the secondary side of PWR steam generators. This paper reviews those electrochemical techniques which are potentially useful to measure denting in tube-support crevices in situ. Attention is also given to corollary needs for monitoring the water chemistry which leads to corrosive attack. Finally some suggestions are offered for corrosion monitoring in autoclaves, model boilers and operating steam generators.

1985-03-01

12

Corrosion studies of carbon steel under impinging jets of simulated slurries of neutralized current acid waste (NCAW) and neutralized cladding removal waste (NCRW)  

Energy Technology Data Exchange (ETDEWEB)

Plans for the disposal of radioactive liquid and solid wastes presently stored in double-shell tanks at the Hanford Site call for retrieval and processing of the waste to create forms suitable for permanent disposal. Waste will be retrieved from a tank using a submerged slurry pump in conjunction with one or more rotating slurry jet mixer pumps. Pacific Northwest Laboratory (PNL) has conducted tests using simulated waste slurries to assess the effects of a impinging slurry jet on the corrosion rate of the tank wall and floor, an action that could potentially compromise the tank`s structural integrity. Corrosion processes were investigated on a laboratory scale with a simulated neutralized cladding removal waste (NCRW) slurry and in a subsequent test with simulated neutralized current acid waste (NCAW) slurry. The test slurries simulated the actual NCRW and NCAW ...

1992-01-01

13

Pitting corrosion of copper coiled tubes in the air conditioning system having the open heat storage water tank; Kaihokei chikunetsuso reionsuika ni okeru kuchokiyo kokan no koshoku ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion ...

1998-11-15

14

Corrosion studies of carbon steel under impinging jets of simulated slurries of neutralized current acid waste (NCAW) and neutralized cladding removal waste (NCRW)  

Energy Technology Data Exchange (ETDEWEB)

Plans for the disposal of radioactive liquid and solid wastes presently stored in double-shell tanks at the Hanford Site call for retrieval and processing of the waste to create forms suitable for permanent disposal. Waste will be retrieved from a tank using a submerged slurry pump in conjunction with one or more rotating slurry jet mixer pumps. Pacific Northwest Laboratory (PNL) has conducted tests using simulated waste slurries to assess the effects of a impinging slurry jet on the corrosion rate of the tank wall and floor, an action that could potentially compromise the tank's structural integrity. Corrosion processes were investigated on a laboratory scale with a simulated neutralized cladding removal waste (NCRW) slurry and in a subsequent test with simulated neutralized current acid waste (NCAW) slurry. The test slurries simulated the actual NCRW ...

1992-01-01

15

Laboratory studies of gas generation and potential for tank wall corrosion during blending of high-level wastes at the West Valley Demonstration Project  

Energy Technology Data Exchange (ETDEWEB)

Laboratory experiments were conducted to simulate the transfer of acidic THOREX waste from Tank 8D-4 into the alkaline PUREX waste in Tank 8D-2 at West Valley. The purpose of the experiments was to explore means of minimizing the production of nitric oxide (NO) gas during mixing of the two wastes and to assess the potential for the gas to further react in the vapor space possibly leading to enhanced corrosion of the tank walls. Forty one THOREX/PUREX mixing tests were conducted to explore the effects of stirring rate, pH, THOREX addition rate, THOREX or PUREX dilution, and temperature. The two most important criteria for minimizing NO production were to maintain some degree of agitation and the keep the pH in the PUREX high, preferably >12. Steel corrosion tests were performed in the presence of low partial pressures of NO{sub 2} and liquid water or water vapor. The NO{sub 2} ...

1995-05-01

16

Helium Tank for Cryoplant  

CERN Document Server

Helium Tank point5

2001-01-01

17

TLA monitoring of an anodic protection system  

Energy Technology Data Exchange (ETDEWEB)

Corrosion is a materials degradation process that engineering personnel in the pulp and paper industry have had to accept as unavoidable to some degree, due to aggressive processing conditions prevalent in paper mills. The increasing incidence of corrosion-related failures in plant and equipment has resulted in the introduction of new techniques to monitor corrosion rates, since many of the more traditional methods do not provide data that is either recent or accurate enough. Thin layer activation (TLA) is a new corrosion monitoring technique which has recently been employed to measure corrosion trends inside a continuous pulp digester. With TLA a surface is irradiated by a particle beam from a nuclear accelerator, causing it to be labelled with an accurate depth profile and low level radioactivity. By monitoring this ...

1992-03-01

18

TLA monitoring of an anodic protection system  

International Nuclear Information System (INIS)

Corrosion is a materials degradation process that engineering personnel in the pulp and paper industry have had to accept as unavoidable to some degree, due to aggressive processing conditions prevalent in paper mills. The increasing incidence of corrosion-related failures in plant and equipment has resulted in the introduction of new techniques to monitor corrosion rates, since many of the more traditional methods do not provide data that is either recent or accurate enough. Thin layer activation (TLA) is a new corrosion monitoring technique which has recently been employed to measure corrosion trends inside a continuous pulp digester. With TLA a surface is irradiated by a particle beam from a nuclear accelerator, causing it to be labelled with an accurate depth profile and low level radioactivity. By monitoring this ...

19

New monitoring system for microbiological control effectiveness on pitting corrosion of carbon steel  

Energy Technology Data Exchange (ETDEWEB)

A new on-line monitoring system has been developed for pitting corrosion monitoring of carbon steel tubes in cooling water systems. This monitoring system was found to be quite sensitive to the microbiological activity relating to pitting corrosion on a real-time basis. The value of galvanic current indicates the performance level of pitting corrosion inhibition even in biocide application. In addition, the changes in the galvanic current provide indicative information about the effectiveness in microbiological control program, even when the pressure drop measurement indicates no biofilm formation. It can be also useful in detecting a microbiological control upset. In this paper, an introduction of the new monitoring system as a microbiological control effectiveness monitor and the field test results are discussed.

1997-12-01

20

Laboratory Evaluation of an Electrochemical Noise System for Detection of Localized and General Corrosion of Natural Gas Transmission Pipelines  

Energy Technology Data Exchange (ETDEWEB)

Gas transmission pipelines are susceptible to both internal (gas side) and external (soil side) corrosion attack. Internal corrosion is caused by the presence of salt laden moisture, CO{sub 2}, H{sub 2}S, and perhaps O{sub 2} in the natural gas. Internal corrosion usually manifests itself as general corrosion. However, the presence of chlorides in entrained water also can lead to pitting corrosion damage. The electrochemical noise technique can differentiate general from localized corrosion and provide estimates of corrosion rates without external perturbation of the corroding system. It is increasingly being applied to field and industrial installations for in situ corrosion monitoring. It has been used here to determine its suitability for monitoring internal and external ...

2003-03-16

21

Monitoring power plant fireside corrosion using corrosion probes  

Energy Technology Data Exchange (ETDEWEB)

The ability to monitor the corrosion degradation of key components in fossil fuel power plants is of utmost importance for Futuregen and ultra-supercritical power plants. Fireside corrosion occurs in the high temperature sections of energy production facilities due to a number of factors: ash deposition, coal composition, thermal gradients, and low NOx conditions, among others. Problems occur when equipment designed for either oxidizing or reducing conditions is exposed to alternating oxidizing and reducing conditions. This can happen especially near the burners. The use of low NOx burners is becoming more commonplace and can produce reducing environments that accelerate corrosion. One method of addressing corrosion of these surfaces is the use of corrosion probes to monitor when process changes cause corrosive ...

2005-01-01

22

STRESS CORROSION CRACKING SUSCEPTIBILITY OF HIGH LEVEL WASTE TANKS DURING SLUDGE MASS REDUCTION  

Energy Technology Data Exchange (ETDEWEB)

Aluminum is a principal element in alkaline nuclear sludge waste stored in high level waste (HLW) tanks at the Savannah River Site. The mass of sludge in a HLW tank can be reduced through the caustic leaching of aluminum, i.e. converting aluminum oxides (gibbsite) and oxide-hydroxides (boehmite) into soluble hydroxides through reaction with a hot caustic solution. The temperature limits outlined by the chemistry control program for HLW tanks to prevent caustic stress corrosion cracking (CSCC) in concentrated hydroxide solutions will potentially be exceeded during the sludge mass reduction (SMR) campaign. Corrosion testing was performed to determine the potential for CSCC under expected conditions. The experimental test program, developed based upon previous test results and expected conditions during the current SMR campaign, consisted of electrochemical and mechanical testing to ...

2007-10-18

23

Corrosion probes for fireside monitoring in coal-fired boilers  

Energy Technology Data Exchange (ETDEWEB)

Corrosion probes are being developed and combined with an existing measurement technology to provide a tool for assessing the extent of corrosion of metallic materials on the fireside in coal-fired boilers. The successful development of this technology will provide power plant operators the ability to (1) accurately monitor metal loss in critical regions of the boiler, such as waterwalls, superheaters, and reheaters; and (2) use corrosion rates as process variables. In the former, corrosion data could be used to schedule maintenance periods and in the later, processes can be altered to decrease corrosion rates. The research approach involves laboratory research in simulated environments that will lead to field tests of corrosion probes in coal-fired boilers. Laboratory research has already shown that electrochemically-measured ...

2005-01-01

24

Development of advanced electrochemical emission spectroscopy for monitoring corrosion in simulated DOE liquid waste. 1998 annual progress report  

Energy Technology Data Exchange (ETDEWEB)

'Objective of this project is to develop and use Electrochemical Emission Spectroscopy (EES) and other electrochemical techniques as in situ tools for exploring corrosion mechanisms of iron and carbon steel in highly alkaline solutions and for continuously monitoring corrosion on structural materials in DOE liquid waste storage system. In particular, the author will explore the fundamental aspects of the passive behavior of pure iron since breakdown of passivity leads to localized corrosion. This report summarizes work after 1 year of a 3 year project.'

1998-06-01

25

Electrochemical noise measurements of sustained microbially influenced pitting corrosion in a laboratory flow loop system.  

Energy Technology Data Exchange (ETDEWEB)

Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. We have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of the trend of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean- square value of the ac components of current and potential ...

1999-01-13

26

Design on SDS2 on-line poison concentration monitoring in CANDU  

Energy Technology Data Exchange (ETDEWEB)

At the reference plant (Wolsung unit No. 1) a manual poison sampling system is provided to periodically sample gadolinium from each tank and analyze it in the laboratory to provide assurance that adequate poison concentration in each tank is maintained. The AECB required a continuous, on-line monitoring system. On Wolsung unit No. 2, process piping adapter and new instrument loops added to the Liquid Injection Shutdown System(LISS) which is part of SDS2. The new instrument loops continuously monitor SDS2 poison conductivity and initiate an alarm when the poison concentration is too low. 8 refs., 1 fig. (author).

1996-10-01

27

Research on pitting corrosion of steam generator heat transfer tubes based on acoustic emission  

International Nuclear Information System (INIS)

Corrosion of steam generator heat transfer tubes (SGHTT) is one of the important problems which affect safety operation of nuclear power plants (NPP), and the hazard of pitting corrosion of heat transfer tubes is the most serious. With an acoustic emission device, the signals during a corrosion test on SGHTT were collected and analyzed, and the corrosion points in the tubes were located accurately. The results show that pitting corrosion of heat transfer tubes has passed through three periods in its development: expansion phase, stationary phase and rapid developing phase. The corrosion damage of HTT can be found earlier with acoustic emission than any other non-destructive testing methods. Acoustic emission can be used for on-line and real-time monitoring of the safety and operation of the steam generator and has therefore a great ...

2010-09-01

28

Statistical characterization of pitting corrosion process and life prediction  

International Nuclear Information System (INIS)

In order to prevent corrosion failures of machines and structures, it is desirable to know in advance when the corrosion damage will take place, and appropriate measures are needed to mitigate the damage. The corrosion predictions are needed both at development as well as operational stage of machines and structures. There are several forms of corrosion process through which varying degrees of damage can occur. Under certain conditions these corrosion processes at alone and in other set of conditions, several of these processes may occur simultaneously. For a certain type of machine elements and structures, such as gears, bearing, tubes, pipelines, containers, storage tanks etc., are particularly prone to pitting corrosion which is an insidious form of corrosion. The corrosion predictions are usually ...

29

Meier associates and Pacific Northwest Laboratory staff exchange: Transfer of corrosion monitoring expertise to assess and develop in-line inspection tools for corrosion control  

Energy Technology Data Exchange (ETDEWEB)

Staff exchanges, such as the one described in this report, are intended to facilitate communication and collaboration among scientists and engineers at DOE laboratories, in US industry, and academia. During the past 5 years, PNL has developed prototype instrumentation to automate the data collection required for electrochemical determination of corrosion rates and behavior of materials in various electrically conductive environments. The last version is labeled the Sentry 100 prototype corrosion data scanner. Applications include these in the pulp and paper industry and at hazardous waste sites.

1995-04-01

30

Electrochemical noise in corrosion  

International Nuclear Information System (INIS)

By varying different variables (potential, chloride content, surface pretreatment etc.) it is possible to show the effect of increasingly harsher corrosion conditions on passive-layer stability. These changes will not be detected by conventional methods e.g. measurement of passive current density, until a very late stage. Electrochemical noise measurement will allow the action of inhibitors to be detected in a rapid and effective manner. High-alloy steels and titanium claddings subjected to pitting corrosion in chloride-containing media demonstrate how to use this method for problem solutions and to open up new practical applications. The effect of mechanical stresses (natural, tensile) on the corrosion system can be detected by electrochemical noise which opens up new methods for crack corrosion studying and monitoring. (orig./DG).

1993-10-07

31

Sodium technology technical progress report, April, May, June 1975  

Science.gov (United States)

Progress is reported in the following areas: radioactivity control technology, FFTF sodium characterization system, corrosion and process control, and fuel failure monitoring systems for FFTF and CRBRP. (JWR)

1975-12-01

32

Groundwater quality assessment plan for single-shell tank waste management Area U at the Hanford Site  

Energy Technology Data Exchange (ETDEWEB)

Waste Management Area U (WMA U) includes the U Tank Farm, is currently regulated under RCRA interim-status regulations, and is scheduled for closure probably post-2030. Groundwater monitoring has been under an evaluation program that compared general contaminant indicator parameters from downgradient wells to background values established from upgradient wells. One of the indicator parameters, specific conductance, exceeded its background value in one downgradient well triggering a change from detection monitoring to a groundwater quality assessment program. The objective of the first phase of this assessment program is to determine whether the increased concentrations of nitrate and chromium in groundwater are from WMA U or from an upgradient source. Based on the results of the first determination, if WMA U is not the source of contamination, then the site will revert to detection monitoring. If WMA U ...

2000-03-21

33

Relining of scrubbers in flue gas desulfurization plants  

Science.gov (United States)

Rubber lining is used as a corrosion protection material in European flue gas desulfurization plants, for scrubbers, tanks, pipe systems, etc. Although these rubber linings can last more than 15 years, relining still is necessary. The difficulty of shutting down power station units requires that the time scale of this replacement be kept to a minimum. High-pressure water systems have proven successful as an efficient method for removal of the old lining. The working steps and time scale are demonstrated for one such relining case.

1999-09-01

34

Large temperature differential thermal storage system. Its design and evaluation  

Energy Technology Data Exchange (ETDEWEB)

A large temperature differential (10K) thermal storage system in a small (4400 m{sup 2}) 8-storey office building is discussed and the monitoring results are analyzed in comparison with computer simulations. Requirements were a comfortable indoor environment and system cost effectiveness. Out of four potential system concepts, the Large Temperature Differential System was chosen. It comprises a flat-type thermal stratification heat storage tank in the under floor pit of the building as the heat source for a variable flow heat pump chiller. The heat sink is a set of serially connected air handling and fan coil units. The tank`s capacity is sized for one day operation and is made as large as possible to shift the electricity demand to night time. To avoid a large size and high cost, the water temperature differential was enlarged. The role of Tokyo Electric Power Company (TEPCO) was to develop the chiller and its control ...

1996-07-01

35

Effect of dissolved oxygen, hydrazine and pH outside the crevice on the galvanic corrosion of support plate alloys  

International Nuclear Information System (INIS)

A study has been performed of the initial corrosion of support structure alloys in crevices of various geometries, when galvanically coupled to alloy 600. Corrosion rates were monitored continuously by measuring the galvanic current flowing in each couple, transduced by a zero impedance ammeter. Experiments were performed in a single-pass flowing electrolyte system, with AVT water pumped through alloy 600 tubing past the orifice of each crevice. Fourteen crevices were studied simultaneously in two parallel flow arms containing seven specimens each. The steady state AVT water pH/hydrazine/oxygen concentrations were controlled by microcomputer, allowing the effect of secondary water chemistry on the corrosion rate to be studied easily. Control of the crevice electrolyte composition was achieved by separately pumping electrolyte, at a low rate, directly into the crevices of the seven specimens in the lower ...

1985-03-01

36

Corrosion failure and its prevention in light water reactor power plants  

Energy Technology Data Exchange (ETDEWEB)

During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel ...

1988-01-01

37

Corrosion failure and its prevention in light water reactor power plants  

International Nuclear Information System (INIS)

During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel ...

38

Nomographs estite floating-roof tank evaporation  

Energy Technology Data Exchange (ETDEWEB)

Nomographs are presented that estimate the evaporation loss from external floating-roof tanks using tank diameter, type of seal, product vapor pressure, and wind velocity.

1986-01-27

39

Maintaining Tank and Infantry Integration Training  

Science.gov (United States)

Page 1. Maintaining Tank and Infantry Integration Training ... 4. TITLE AND SUBTITLE Maintaining Tank and Infantry Integration Training 5a. ...

2005-01-11

40

Integrated vermi-pisciculture - an alternative option for recycling of solid municipal waste in rural India  

Energy Technology Data Exchange (ETDEWEB)

Vermicomposts as a biofertilizer can be a great option for pond manuring as they never cause any long term harm to the soil like chemical fertilizer. In this study vegetable and horticulture waste was used as an important media for vermiculture. Three separate cemented tanks (6 m{sup 3} each) were used in the system as control tank, vermicompost fertilized tank and inorganic fertilizer manured tank. Monoculture of fish was carried out with cat fish, Clarias batrachus. The produced earthworms were used as fish feed. Regular monitoring of water parameter was conducted in three different ponds. Specifically, the algal biomass variation was quite helpful in analysing the behavior of the ponds. NPK value of soil samples was analyzed intermittently to know the eutrophication level. Despite the hot summer temperature in northern part of India, which is not ideal for fish growth, we have ...

2004-05-01

41

Significance of chemical return in nuclear steam generators  

International Nuclear Information System (INIS)

A reasonable understanding of PWR steam generator corrosion mechanisms such as denting and wastage has been developed, and adequate chemistry control programs defined to obviate the magnitude and effects of these modes of attack. However, relatively unique corrosion attack modes have been encountered at several plants notwithstanding the presence of a reasonable to very good chemistry control program when considered in light of the Steam Generator Owners Group chemistry guidelines. The uniqueness of attack also suggests that parameters not routinely measured or monitored may be playing a significant role. In the authors opinions, the only reasonable method of routinely identifying corrosion accelerating species present in crevices, sludge piles, and deposits in PWR steam generators is by performing detailed chemical return studies during power transients, shutdowns, and long term layups. Although it ...

1985-03-01

42

Combustible Metallic Igniter Casing for Tank Guns  

Science.gov (United States)

... TANK GUNS, GUNS, CHAMBERS, IGNITERS, INTERIOR BALLISTICS, INTERNAL PRESSURE, COMBUSTIBLE CARTRIDGE CASES, METALS. ...

1991-11-01

43

Replacement of fishmeal in cobia (Rachycentron canadum) diets using poultry by-product meal  

British Library Electronic Table of Contents (United Kingdom)

An 8-week feeding trial was conducted to evaluate the use of local poultry by-product meal (PBM) in replacement of imported fishmeal in the diets of cobia, Rachycentron canadum. Six isolipidic (12%) and isoproteic (45%) experimental diets were formulated using PBM to replace fishmeal at 20, 40, 60, 80 and 100% dietary protein. Eleven juvenile cobia (initial mean weight of 30.7???0.78?g) were randomly stocked in 300-L circular fibreglass tanks and hand-fed based on the total biomass of each tank, twice a day at 0900?h and 1500?h. The fish were group weighed at 2-week intervals to monitor their growth performance in order to adjust the feeding ratio. At the end of the feeding trial, weight gains (WGs) ranging from 221 to 322% were obtained. The specific growth rate (SGR), WG and protein effi...

2011-01-01

44

Effect of lead and silicon on localized corrosion of Alloy 800 in steam generator crevice environments  

Energy Technology Data Exchange (ETDEWEB)

The Alloy 800 tubes used in CANDU 6 steam generators have not experienced significant corrosion damage to date, which may be attributed to successful water chemistry control strategies. However, it is known that Alloy 800, like other steam generator (SG) tubing materials, is not immune to corrosion, especially pitting, under some plausible but off-specification operating scenarios. Electrochemical measurements provide information on corrosion susceptibility and rate, which are known to be a function of water chemistry. Using laboratory data in combination with chemistry monitoring and diagnostic software it is possible to assess the impact of plant operating conditions on SG tube corrosion for plant life management (PLIM). In this context, this paper discusses the results of electrochemical measurements made to elucidate the corrosion behaviour of Alloy 800 SG ...

2001-09-01

45

Life time management at the Dukovany nuclear power plant  

International Nuclear Information System (INIS)

The paper discusses the role of the Life Management Programme in ensuring a safe operation of the Dukovany nuclear power plant. The Programme involves the following major items: (i) primary circuit materials degradation assessment, (ii) pipeline damage control by the Flow Assisted Corrosion Monitoring and Prediction Programme, and (iii) the DIALIFE diagnostic system. (author)

46

Brine chemistry and control of adverse chemical reactions with natural gas production. Annual report, January-December 1986  

Energy Technology Data Exchange (ETDEWEB)

Monitoring brine chemistry to determine the extent of potential adverse reactions has been simplified by the development of a field-brine test kit and a series of nomographs. Results of the kit analyses serve as input to the nomographs, which provide a graphic means of determining the scaling tendency (Saturation Index value) of a brine. Brines that do not tend to form scale may be corrosive. Saturation Index values were correlated with various processes using data from geopressured wells in the Gulf Coast area. Control of scale in surface equipment with chemical inhibitors has been successful. Numerous laboratory simulations of inhibitor squeeze operations were completed using core material with calcite present and absent. The corresponding wells were squeezed with phosphorous-containing inhibitors, and the flowback of brine was monitored for phosphorous concentrations vs time. A new procedure to measure the concentration ...

1987-01-01

47

FIELD CORROSION TESTS FOR COMPARISON OF ...  

Science.gov (United States)

... Accession Number : ADD457408. Title : FIELD CORROSION TESTS FOR COMPARISON OF CORROSIVITY IN JAPAN AND CHINA. ...

48

Evaluation of methods to measure surface level in waste storage tanks: Second test sequence  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results of a program conducted at the Pacific Northwest Laboratory (PNL) and Westinghouse Hanford Company (WHC) to identify alternative methods to measure the surface level in the waste tanks. This program examined commercially available devices for measuring the distance to a target. This is a continuation of a program started in FY93. In the first test sequence, tests were performed.on five devices to determine their applicability to measure the surface level in the waste tanks. The devices were the Enraf-Nonius{trademark} Model 872 Radar Gauge, the Enraf-Nonius{trademark} Model 854 Advanced Technology Gauge (ATG), the Stanley Tool Laser Measuring Device, the Robertshaw Inven-Tel{reg_sign} Precision Level Gauge, and the Micro Switch Model 942 Acoustic Sensor. In addition, discussions were held with several manufacturer representatives regarding other potential devices. The results of these tests were documented in a ...

1993-09-01

49

Energy use in swine unit in the finishing system with waste treatment; Uso de energia em unidade suinicola em sistema de terminacao com tratamento de residuos  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess the energy flux and energetic balance related to the swine production and the recycling of residues generated by the system for utilization as organic fertilizers. The experiment was carried out at Vale dos Ipes Farm, located in the city of Ouro Verde do Oeste, in the Western of Parana State. One finishing phase swine unity containing 600 animals was monitored from January to June 2005. The treatment system is composed by one steel digester with capacity for 50 m{sup 3}, one sedimentation tank, one algae tank and one bio fertilizer storage tank. The swine barn cleaning is performed by dry scratching on a daily basis. The generated residues flow by gravitation through ducts towards the digester. The duration of the hydraulic retention period was 12 days. In the calculation of energetic efficiency, the energetic component ration is the greatest energetic cost in ...

2006-07-01

50

Criticality safety review of FFTF interim decay storage tank  

Science.gov (United States)

The Interim Decay Storage tank (IDS) will be located in a concrete cell in the FFTF reactor building. The tank will have capacity to store 112 driver fuel assemblies and 10 test assemblies in sodium. A criticality safety analysis for the design of the IDS tank was performed. From the analysis, it is concluded that under normal operating conditions and minor abnormal conditions that might shift the fuel, the IDS tank will remain adequately subcritical. (auth)

1975-10-01

51

How do we impact corrosion?  

Science.gov (United States)

Page 1. How do we impact corrosion? US Army Corrosion Summit Feb. ... Page 4. Leaders in Corrosion Control Technology Impact of Corrosion - $$ ...

2009-02-03

52

Conceptual fusion power monitor based on the "1"6O(n,p)"1"6N reaction  

International Nuclear Information System (INIS)

The feasibility of developing a fusion power monitor based on a fluid activation detector is considered here. The activation fluid may be either a liquid or a gas and its composition can be selected from a number of candidate materials to provide desired activation and decay characterisitcs. Performance calculations indicate that ordinary water would be a nearly ideal activation fluid. The "1"6O(n,p)"1"6N reaction has a threshold at about 10 MeV and a cross section energy dependence giving it a predominant response for unmoderated D-T fusion neutrons. Adequate activation can be obtained at moderate flow rates for remote counting away from the high radiation area of the reactor. The 7.16 sec half-life of "1"6N is ideal for remote counting with subsequent decay in a small hold-up tank to eliminate activity build-up in the recycled water.

1981-07-01

53

Structural acceptance criteria for the evaulation of existing double-shell waste storage tanks located at the Hanford site, Richland, Washington  

Energy Technology Data Exchange (ETDEWEB)

The structural acceptance criteria contained herein for the evaluation of existing underground double-shell waste storage tanks located at the Hanford Site is part of the Life Management/Aging Management Program of the Tank Waste Remediation System. The purpose of the overall life management program is to ensure that confinement of the waste is maintained over the required service life of the tanks. Characterization of the present condition of the tanks, understanding and characterization of potential degradation mechanisms, and development of tank structural acceptance criteria based on previous service and projected use are prerequisites to assessing tank integrity, to projecting the length of tank service, and to developing and applying prudent fixes or repairs. The criteria provided herein summarize the requirements for the analysis and ...

1995-09-01

54

Decontamination of spent fuel dissolution tank  

International Nuclear Information System (INIS)

The decontamination of the dissolution tank from spent fuel reprocessing out-ling device is studied, by using FL-AP decontamination agent. The decontamination factor per step is 2.2, 2.4, respectively for #alpha#, #beta# activities. After dissecting the tank, residual contamination in inner surface of the tank was found to be non-uniform. The exact original contamination value of the tank surface could be approximated by calculating the total amounts of radionuclide distributed on the hanging specimens, the dissecting specimen, and radioactive level in waste decontamination agent. Therefore, it can be concluded that the hanging specimens method is feasible for measuring the decontamination factor of spent fuel dissolution tank. (authors)

2006-01-01

55

Decontamination of the reactor coolant pump in Maanshan nuclear power plant  

International Nuclear Information System (INIS)

To reduce the radiation dose that accumulated on the reactor coolant pump, decontamination work was carried out at the Maanshan Nuclear Power Plant. A four-step alkaline permanganate (AP)-CanDecon process was applied to remove the activity on the turning vane diffuser and pump impeller. The first step consisted of 8 h of AP treatment and 7 h of decontamination. It was followed by 2.5 h of AP treatment and 5 h of decontamination. An average decontamination factor of 2.9 was obtained. To understand the corrosion of the decontaminating reagents on the materials, coupons were installed in the decontamination tank. These were as-received and sensitized 304SS, alloy 600, casting stainless steel (CF-8), stellite-6, and carbon steels (A508 and A533). The exposure rates (mR h"-"1) of the carbon steels were approximately five times higher in magnitude than those of the other materials. The decontamination levels (dpm per 100 cm"2) of the A508 and A533 ...

56

Application and evaluation of processing methods of electrochemical noise generated during stress corrosion cracking  

Energy Technology Data Exchange (ETDEWEB)

Electrochemical noise generated during stress corrosion cracking (SCC) of type 304 stainless steel (UNS S30400) and {alpha}-brass were studied. Noise patterns showed common characteristics (i.e., a quick drop and slow recovery of the potential). The quick drop corresponded to the initiation of localized events where fresh metal was exposed. The slow recovery corresponded to the repassivation process of the exposed bare metal. The potential drop rate and recovery rate were almost constant during the SCC process for a given SCC system. For random noise, rates of potential rise and drop were similar. Frequency of the noise generated during SCC increased with an increase in applied stress. SCC initiation could be monitored and determined according to noise characteristics and distribution. Since the shift of background potentials had an obvious influence on characteristics of power spectrum density (PSD), the direct current (DC) component should be ...

1999-09-01

57

Brine chemistry and control of adverse chemical reactions with natural gas production. Annual report, January-December 1984  

Energy Technology Data Exchange (ETDEWEB)

Monitoring brine chemistry to determine the extent of potential adverse reactions was simplified by the development of a field brine test kit and a series of nomographs. Results of the kit analyses serve as input to the nomographs, which provide a graphic means of determining the scaling tendency (Saturation Index value) of a brine. Brines that do not tend to form scale may be corrosive. Saturation Index values have been correlated with various processes using data from geopressured wells in the Gulf Coast area. Control of scale in surface equipment of geopressured wells by chemical inhibitors has been successful. Downhole treatment with inhibitors to prevent scale formation in the production tubing is being investigated. Laboratory simulations indicate that an inhibitor squeeze treatment may be successful at the Gladys McCall No. 1 well. Inhibitor mixtures exhibit additive behavior at minimum concentration levels; however, behavior at maximum ...

1985-01-01

58

Hideout return testing from support crevices  

International Nuclear Information System (INIS)

The objectives of the project were to develop operational techniques for promoting contaminant hideout return from tube support crevices and to identify the effect of chemical inhibitor application on corrodent transport. The implementation of routine procedures for promoting the return of sequestered corrodents could retard the progression of denting or other corrosion processes and improve steam generator availability. Tests also quantified the effect of inhibitor application on crevice hideout and hideout return processes, with the intention of developing a better understanding of the inhibition mechanism. By carefully monitoring the hideout and hideout return inventories, the program also has provided the opportunity to study steam generator concentration processes in general.

1985-03-01

59

Reliability engineering in aerospace technology. Approach to the assurance of high reliability; Eisei uchu rocket no shinraisei. Koshinraisei eno torikumi  

Energy Technology Data Exchange (ETDEWEB)

This paper describes an approach to the reliability engineering in aerospace technology. To promote development, configuration management (clarifies the base line of technology), reliability management, quality control, safety management, progress management, and cost management are very important. The following example related to reliability was contained for the development of an N-1 rocket in Japan. A timer and amplifier that are old-fashioned but have actual results were supplied from abroad. The induction system that was purchased from abroad contained faulty components in quality control. The improvement in reliability has priority and the first-stage tank was changed to a home-made aluminum alloy that is superior in stress-resistant corrosiveness. An H-II rocket was completely developed in Japan by self-technology. The number of faults to be generated in the H-II rocket decreases as compared with the N-1 rocket. In the combustion test of ...

1995-02-05

60

Thermal convection loop study of corrosion of alloy 800 in molten NaNO/sub 3/-KNO/sub 3/  

Energy Technology Data Exchange (ETDEWEB)

Maximum metal loss rate of Alloy 800 coupons was about 0.5 mil/year and occurred at the maximum temperature of 600/sup 0/C. Significantly greater oxide penetration into the alloy occurred in unabraded as-received tubing. Since the corrosion rate of unabraded tubing was less temperature sensitive than polished coupons, and attained a maximum value at temperatures in the range of 550 to 565/sup 0/C, a value of 1 mil/year should be used as the corrosion rate for design purposes. Because daily thermal cycling is inherent in solar central receiver operation, oxidation and chromium depletion rates can be expected to increase if surface oxide layers spall. The oxide layers formed on Alloy 800 appeared to be adherent, and adherence will benefit further from growth-derived compressive stresses in oxide layers on the salt-exposed inner diameter of receiver tubes. Since the lower duty factor in diurnal solar service may offset the accelerated metal loss ...

1983-01-01

61

CONVERTING WASTE  

Wastenet

condenser, gas refiner, oil (gas) storage tank and dual fuel engine

64

The feasibility of using a septic tank as a heat source for geothermal heat pumps  

Energy Technology Data Exchange (ETDEWEB)

A geothermal heat pump (GHP) system with three ground coils was installed in a residence in northern Idaho with a portion of the ground heat exchanger wrapped around the residential septic tank. The septic coil provided a significant portion of the heating for the residence over the heating season. There was no evidence of the septic tank freezing up or failing to properly function. Utilizing a septic tank as a heat source for GHP systems is feasible design option if the septic tank is used on a full-time basis. However, the tank should be surrounded on all sides by a large amount of soil and/or insulated from the ground surface to ensure that ground temperatures near the tank remain warm during the winter.

1999-11-01

65

Instrumentation for monitoring and control of water chemistry for light-water-cooled nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

Based on the IAPWS technical guidance on ''Instrumentation for Monitoring and Control of Cycle Chemistry for Steam-Water Circuits of Fossil-Fired and Combined Cycle Power Plants,'' the latest situation regarding instrumentation for nuclear power plants is discussed. As a result of the discussion, it is concluded that: (1) Reliable and safe operation of plants is established by the application of suitable chemical conditions in plant cooling systems, which should be supported by the selection of suitable control targets for monitoring and by the application of reliable instruments. (2) The minimum level of key instrumentation consists of on-line as well as off-line instruments for monitoring the key parameters: - on-line: pH, conductivity, cation conductivity, O{sub 2} and H{sub 2} concentrations, electrochemical corrosion potential; - off-line: radioactive nuclides ...

2010-05-15

66

Corrosion Brochure - KSC Corrosion Technology Laboratory Home - NASA  

Science.gov (United States)

Specialized tests can be designed to study impingement-corrosion, erosion- corrosion, cathodic protection systems, cavitation and other velocity effects. ...

67

Hanford tanks initiative plan  

Energy Technology Data Exchange (ETDEWEB)

Abstract: The Hanford Tanks Initiative (HTI) is a five-year project resulting from the technical and financial partnership of the U.S. Department of Energy`s Office of Waste Management (EM-30) and Office of Science and Technology Development (EM-50). The HTI project accelerates activities to gain key technical, cost performance, and regulatory information on two high-level waste tanks. The HTI will provide a basis for design and regulatory decisions affecting the remainder of the Tank Waste Remediation System`s tank waste retrieval Program.

1997-07-01

68

Radiation testing of organic ion exchange resins  

International Nuclear Information System (INIS)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of "1"3"7Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated ...

1983-04-11

69

Radiation testing of organic ion exchange resins  

Energy Technology Data Exchange (ETDEWEB)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated ...

1995-09-01

70

Quantifying the Reactive Uptake of OH by Organic Aerosols in aContinuous Flow Stirred Tank Reactor  

Energy Technology Data Exchange (ETDEWEB)

Here we report a new method for measuring the heterogeneous chemistry of submicron organic aerosol particles using a continuous flow stirred tank reactor. This approach is designed to quantify the real time heterogeneous kinetics, using a relative rate method, under conditions of low oxidant concentration and long reaction times that more closely mimic the real atmosphere. A general analytical expression, which couples the aerosol chemistry with the flow dynamics in the chamber is developed and applied to the heterogeneous oxidation of squalane particles by hydroxyl radicals (OH) in the presence of O2. The particle phase reaction is monitored via photoionization aerosol mass spectrometry and yields a reactive uptake coefficient of 0.51+-0.10, using OH concentrations of 1-7x108 molec cdot cm-3 and reaction times of 1.5+-3 hours. This uptake coefficient is larger than that found for the reaction carried out under high OH concentrations (~;;1x1010 ...

2009-03-01

71

Field performance of a premium heating oil  

Energy Technology Data Exchange (ETDEWEB)

As part of our ongoing research to provide quality improvements to heating oil, Mobil Oil together with Santa Fuel, Inc., conducted a field trial to investigate the performance of a new premium heating oil. This premium heating oil contains an additive system designed to minimize sludge related problems in the fuel delivery system of residential home heating systems. The additive used was similar to others reported at this and earlier BNL conferences, but was further developed to enhance its performance in oil heat systems. The premium heating oil was bulk additized and delivered to a subset of the customer base. Fuel related, unscheduled service calls were monitored in this test area, as well as in a similar baseline area that did not receive the premium heating oil. Overall, the premium fuel provided a 45% reduction in the occurrence of fuel related, unscheduled service calls as compared to the baseline area. Within this population, there was a reduction of 38% ...

1996-07-01

72

Liquid waste evaporator operating experience  

Energy Technology Data Exchange (ETDEWEB)

Atomic Energy of Canada Limited (AECL) operates the Waste Treatment Centre (WTC) to treat and immobilize some of the low- level radioactive waste (LLRW) streams at the Chalk River Laboratories (CRL). The WTC at treats low- level radioactive liquid waste by removing the contaminants from the wastewater, concentrating them, and immobilizing them. The fundamental design concept for the WTC is to process the waste streams using forced circulation type liquid waste evaporation (LWE), to solidify the concentrates using thin film evaporator and to discharge the purified effluent into the Ottawa River following verification monitoring. The solidified product drums are stored in existing storage facilities in the CRL. The LWE was installed in the WTC to treat the LLRW. After about four (4) years of design, construction and cold commissioning, the active commissioning of the evaporator process using radioactive waste streams commenced in February 2000. The LWE has overcome ...

2006-07-01

73

Liquid waste evaporator operating experience  

International Nuclear Information System (INIS)

Atomic Energy of Canada Limited (AECL) operates the Waste Treatment Centre (WTC) to treat and immobilize some of the low- level radioactive waste (LLRW) streams at the Chalk River Laboratories (CRL). The WTC at treats low- level radioactive liquid waste by removing the contaminants from the wastewater, concentrating them, and immobilizing them. The fundamental design concept for the WTC is to process the waste streams using forced circulation type liquid waste evaporation (LWE), to solidify the concentrates using thin film evaporator and to discharge the purified effluent into the Ottawa River following verification monitoring. The solidified product drums are stored in existing storage facilities in the CRL. The LWE was installed in the WTC to treat the LLRW. After about four (4) years of design, construction and cold commissioning, the active commissioning of the evaporator process using radioactive waste streams commenced in February 2000. The LWE has overcome ...

2005-05-08

74

Development of a 1200 KW/CYL low pressure dual fuel engine for LNG carriers  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design and feasibility tests of a 570 mm bore 4 stroke low pressure (L.P.) dual fuel engine rated at 20.9 bar BMEP meant for the propulsion of LNG carriers. The basic design features which are to be in accordance with classification societies safety rules are described: individual electro hydraulic valves located in the air manifold ducts, pilot injection, monitoring system etc. The engine capability to burn variable liquid/gas fuel proportions have been investigated with diesel oil and heavy fuel and possible running zones are defined. This ensures the possibility of the engine to cope with the different boil off gas quantity emanating from the ship`s tank during her loaded - and ballast - journeys. With the very lean setting of this engine, no adverse influence of the high ash lube-oil additives were found during the tests. Further tests are necessary to confirm that possible more significant fouling of the combustion ...

1998-12-31

75

/sup 252/Cf-source-driven neutron noise analysis method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven neutron noise analysis method has been tested in a wide variety of experiments that have indicated the broad range of applicability of the method. The neutron multiplication factor k/sub eff/ has been satisfactorily detemined for a variety of materials including uranium metal, light water reactor fuel pins, fissile solutions, fuel plates in water, and interacting cylinders. For a uranyl nitrate solution tank which is typical of a fuel processing or reprocessing plant, the k/sub eff/ values were satisfactorily determined for values between 0.92 and 0.5 using a simple point kinetics interpretation of the experimental data. The short measurement times, in several cases as low as 1 min, have shown that the development of this method can lead to a practical subcriticality monitor for many in-plant applications. The further development of the method will require experiments oriented toward particular applications ...

1985-01-01

76

Phase Chemistry of Tank Sludge Residual Components  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) has millions of gallons of high level nuclear waste stored in underground tanks at Hanford, Washington and Savannah River, South Carolina. These tanks will eventually be emptied and decommissioned. This will leave a residue of sludge adhering to the interior tank surfaces that may contaminate nearby groundwaters with radionuclides and RCRA metals. Performance assessment (PA) calculations must be carried out prior to closing the tanks. This requires developing radionuclide release models from the sludges so that the PA calculations can be based on credible source terms. These efforts continued to be hindered by uncertainties regarding the actual nature of the tank contents and the distribution of radionuclides among the various phases. In particular, it is of vital importance to know what radionuclides are associated with solid sludge components. ...

2002-04-02

77

Structural steels with improved atmospheric corrosion resistance  

CERN Document Server

Structural steels with improved atmospheric corrosion resistance

2003-01-01

79

Corrosion Protection of special steels and alloys  

International Science & Technology Center (ISTC)

Development of the Corrosion Protection Technology for Special Steels and Alloys

80

Enhanced defect detection and sizing accuracy using matrix phased array ultrasonic tools  

Energy Technology Data Exchange (ETDEWEB)

Although ultrasonic testing inspection technology and tools have improved significantly, there is still a need for more reliable detection, monitoring, and accurate sizing of crack-like and planar defects, complex corrosion damage, and detection of secondary features within deformed pipe. Ultrasonic two dimensional (2D) matrix phased array technology offers some unique advantages that make the technology promising for improving detection and sizing of pipeline flaws resulting from welding or from in-service damage. Ultrasonic modeling and simulation has been conducted to evaluate the detection and sizing capabilities of 2D matrix arrays for various pipeline inspection concepts. Simulations have been performed using both flexible and rigid array probes. Inspection concepts using rigid probes were evaluated for inspections from both the outside and inside pipe surfaces, while flexible probes were evaluated primarily for inspection from the ...

2009-07-01

81

Phase chemistry and radionuclide retention of high level radioactive waste tank sludges  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) has millions of gallons of high level nuclear waste stored in underground tanks at Hanford, Washington and Savannah River, South Carolina. These tanks will eventually be emptied and decommissioned. This will leave a residue of sludge adhering to the interior tank surfaces that may contaminate groundwaters with radionuclides and RCRA metals. Experimentation on such sludges is both dangerous and prohibitively expensive so there is a great advantage to developing artificial sludges. The US DOE Environmental Management Science Program (EMSP) has funded a program to investigate the feasibility of developing such materials. The following text reports on the success of this program, and suggests that much of the radioisotope inventory left in a tank will not move out into the surrounding environment. Ultimately, such studies may play a significant role in developing safe and ...

2000-05-19

82

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

83

Enabling Technology for Monitoring & Predicting Gas Turbine Health & Performance in IGCC Powerplants  

Energy Technology Data Exchange (ETDEWEB)

The ''Enabling & Information Technology To Increase RAM for Advanced Powerplants'' program, by DOE request, was re-directed, de-scoped to two tasks, shortened to a 2-year period of performance, and refocused to develop, validate and accelerate the commercial use of enabling materials technologies and sensors for coal/IGCC powerplants. The new program was re-titled ''Enabling Technology for Monitoring & Predicting Gas Turbine Health & Performance in IGCC Powerplants''. This final report summarizes the work accomplished from March 1, 2003 to March 31, 2004 on the four original tasks, and the work accomplished from April 1, 2004 to July 30, 2005 on the two re-directed tasks. The program Tasks are summarized below: Task 1--IGCC Environmental Impact on high Temperature Materials: The first task was refocused to address IGCC environmental impacts on high temperature materials used in gas ...

2005-12-01

84

Passivation of uranium metal by radio-frequency plasma nitriding against gas phase (H{sub 2}, H{sub 2}O) corrosion  

Energy Technology Data Exchange (ETDEWEB)

Thin passive layers of uranium nitride were formed by nitriding pure metallic uranium in non-equilibrium, low pressure radio-frequency plasma of nitrogen. Plasma nitriding at low substrate temperature of 230 C-250 C was found to cause the formation of adherent layers of uranium sesquinitride ({alpha}-U{sub 2}N{sub 3}) which provide a considerable protection against hydrogen attack. The characteristics of these passivation layers were determined by X-ray diffraction and Auger electron spectroscopy. The incipient hydriding kinetics of the plasma-treated samples were compared with those of untreated and nitrogen-ion implantation ones, utilizing a hot-stage microscope that was monitored continuously with a TV camera and videotape. (orig.)

1996-07-01

85

Possible explosive compounds in the Savannah River Site waste tank farm facilities  

Energy Technology Data Exchange (ETDEWEB)

This report will be revised upon completion of current testing investigating the radiolytic stability of additional energetic materials and the analysis of tank farm samples for volatile and semi-volatile organic compounds.

2000-04-13

86

Charts give vapor loss from internal floating-roof tanks  

Energy Technology Data Exchange (ETDEWEB)

Nomographs have been constructed to estimate the average evaporation loss from internal floating-roof tanks. Loss determined from the charts can be used to evaluate the economics of seal conversion and to reconcile refinery, petrochemical plant, and storage terminal losses. The losses represent average standing losses only. They do not cover losses associated with the movement of product into or out of the tank. The average standing evaporation loss from an internal floating-roof tank depends on: vapor pressure of the product; type and condition of roof seal; tank diameter; and type of fixed roof support. The nomographs can estimate evaporation loss for product true vapor pressures (TVP) ranging from 1.5 to 14 psia, the most commonly used seals for average and tight fit conditions, tank diameters ranging from 50 to 250 ft, welded and bolted designs, and both self-supporting and ...

1987-03-09

87

Assessing the internal mechanical integrity of power transformers using vibration tests  

Energy Technology Data Exchange (ETDEWEB)

Machine condition monitoring (MCM) has the capability to predict equipment maintenance needs which can reduce forced down-time and facilitate the avoidance of catastrophic failures and the consequential secondary damage. It can be used to allow confident deferral of routine maintenance, and improve equipment performance, availability, reliability and safety. In order to capitalize on the potential benefits of MCM directed toward power transformers two types of vibration tests were conducted on transformers owned and operated by Cargill Inc. and IES Utilities at the Bridgeport corn plant in Eddyville, Iowa. These tests involved collecting vibration signals from the transformer tank walls during transformer energization at no-load and during steady state operation at various loads. These vibration signals were then used to detect deterioration of internal mechanical integrity. Both types of tests conducted on the transformers at the Eddyville ...

1996-12-31

88

Tank of sodium cooled fast reactor  

International Nuclear Information System (INIS)

Object: To provide a tank, which can safely and reliably accommodate high temperature sodium containing radioactive substance in case of occurrence of an accident in a sodium system and thus prevent spread of contamination. Structure: A sodium drain duct inserted into a tank from above the tank is provided at the position of its lower end with a buffer means for preventing direct flow-down of sodium to a bottom plate. A means for preventing the discharge of radioactive substance to the cover gas is provided above the lower end of the sodium drain tube so as to surround the sodium drain tube. (Kamimura, M.).

89

Production Data Package 267 Gallon External Fuel Tank  

Science.gov (United States)

... It is recommended that the drawings be validated in accordance with NAVAIRINST 4333.10 and the data package, Appendix A, be used for ...

1973-08-23

90

High-level waste tank modifications, installation of mobilization equipment/check out  

Energy Technology Data Exchange (ETDEWEB)

PUREX high-level waste (HLW) is contained at the West Valley Demonstration Project (WVDP) in an underground carbon-steel storage tank. The HLW consists of a precipitated sludge and an alkaline supernate. This report describes the system that the WVDP has developed and implemented to resuspend and wash the HLW sludge from the tank. The report discusses Sludge Mobilization and Wash System (SMWS) equipment design, installation, and testing. The storage tank required modifications to accommodate the SMWS. These modifications are discussed as well.

1992-08-31

91

Early Season Applications of Fluridone for Control of Curlyleaf ...  

Science.gov (United States)

... While the large tanks served to regulate the water temper- ature, the polypropylene aquaria served as independent experimental units. ...

2010-12-01

92

Glass Furnace Combustion and Melting Research Facility.  

Energy Technology Data Exchange (ETDEWEB)

The need for a Combustion and Melting Research Facility focused on the solution of glass manufacturing problems common to all segments of the glass industry was given high priority in the earliest version of the Glass Industry Technology Roadmap (Eisenhauer et al., 1997). Visteon Glass Systems and, later, PPG Industries proposed to meet this requirement, in partnership with the DOE/OIT Glass Program and Sandia National Laboratories, by designing and building a research furnace equipped with state-of-the-art diagnostics in the DOE Combustion Research Facility located at the Sandia site in Livermore, CA. Input on the configuration and objectives of the facility was sought from the entire industry by a variety of routes: (1) through a survey distributed to industry leaders by GMIC, (2) by conducting an open workshop following the OIT Glass Industry Project Review in September 1999, (3) from discussions with numerous glass engineers, scientists, and executives, and (4) during visits to ...

2004-08-01

93

Load requirements for maintaining structural integrity of Hanford single-shell tanks during waste feed delivery and retrieval activities  

Energy Technology Data Exchange (ETDEWEB)

This document provides structural load requirements and their basis for maintaining the structural integrity of the Hanford Single-Shell Tanks during waste feed delivery and retrieval activities. The requirements are based on a review of previous requirements and their basis documents as well as load histories with particular emphasis on the proposed lead transfer feed tanks for the privatized vitrification plant.

1999-09-22

94

Experience with Aerosol Generation During Rotary Mode Core Sampling in the Hanford Single Shell Waste Tanks  

Energy Technology Data Exchange (ETDEWEB)

This document provides data on aerosol concentrations in tank headspaces, total mass of aerosols in the tank headspace, and mass of aerosols sent to the exhauster during rotary mode core sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based upon operational data and non-destructive assay.

2001-03-23

95

Experience with Aerosol Generation During Rotary Mode Core Sampling in the Hanford Single Shell Waste Tanks  

Energy Technology Data Exchange (ETDEWEB)

This document provides data on aerosol concentrations in tank head spaces, total mass of aerosols in the tank head space and mass of aerosols sent to the exhauster during Rotary Mode Core Sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based on operation data.

2000-01-24

96

Heavy Metals in Vehicles II  

Wastenet

Hexavalent chromium in corrosion preventive coating 64 ...To prevent corrosion of rims, weights can be provided with a coating. ...integrated clips brought up technical problems due to corrosion

97

Corrosive Fumes Equipment on Environmental Expert  

Wastenet

... Corrosive Fumes Equipment on Environmental Expert Find and compare a variety of corrosive fumes equipment on the world's largest environmental industry portal. View ...

98

Corrosion Inhibitors Equipment on Environmental Expert  

Wastenet

... Corrosion Inhibitors Equipment on Environmental Expert Find and compare a variety of corrosion inhibitors equipment on the world's largest environmental industry portal. View ...

99

From tankers to tissues : tracking the degradation and fate of oil discharges in Port Valdez, Alaska  

Energy Technology Data Exchange (ETDEWEB)

An average of 9 million gallons per day of oil-contaminated ballast water off loaded from tankers are treated at the Alyeska Pipeline Service Company Ballast Water Treatment Facility at the terminus of the Trans-Alaska Pipeline in Port Valdez, Alaska. This paper focuses on the results of 2 Prince William Sound Regional Citizens' Advisory Council monitoring programs which detail changes in the chemical composition of treated ballast water as it moves from tankers through the facility and subsequently traces the effluent hydrocarbons into the receiving environment of Port Valdez. The treatment facility involves gravity separation tanks, dissolved air flotation cells and biological treatment tanks. Effluent containing traces of volatile aromatics, including benzene, toluene, ethylbenzene and xylenes, low levels of oil, saturated hydrocarbons and polycyclic aromatic hydrocarbons is being continuously discharged to Port ...

2005-07-01

100

Corrosion inhibition of steel in crude oil storage tanks  

Energy Technology Data Exchange (ETDEWEB)

The corrosion behavior of steel in water from certain oil fields with various organic inhibitors was studied by applying potentiodynamic technique at pH 5.9. The inhibitors which were used include 2-methylbenzimidazole (I), 2-mercaptobenzimidazole (II), 2-mercapto-5-methylbenzimidazole (III), and 2-mercaptothiazole (IV). The inhibiting efficiency of the different additives was evaluated from their anodic and cathodic polarization curves at different temperatures. A comparative study of curve fitting procedures using the kinetic thermodynamic model and those utilizing well-known adsorption isotherms was undertaken. Three types of isotherms were used, Langmuir, Frumkin and Flory-Huggins isotherm. The results show that the kinetic-thermodynamic model and Flory-Huggins isotherms are more suitable to fit the data for the four inhibitors, at all applied temperatures. From the values of binding constants, K, the order of inhibitor efficiency is: III > IV > ...

2003-04-01

101

Effect of boric acid on steam generator corrosion  

International Nuclear Information System (INIS)

Project RPS116, ''Implementation of Boric Acid in the Field,'' was designed to demonstrate that a selected steam generator boric acid treatment is effective in arresting the progressing of denting in an operating steam generator. The PWR nuclear steam generators chosen for the testing were those at the Indian Point Unit 3 nuclear site. Hydrogen monitoring measurements and eddy current examinations had indicated that the Indian Point Unit 3, Series 44 steam generators had already reached an advanced stage of denting and tube support plate ligament discontinuities were observed. The objective of the boric acid treatment was to reduce the rate of denting by attempting to reproduce in the field the positive results achieved with boric acid in laboratory-simulated denting tests. Laboratory testing has indicated that implementation of a four day low power (25% power) boric acid soak with 50 ppm boron as boric acid followed by maintenance of a 5-10 ppm boron level during ...

1985-03-01

102

Effect of applied tensile stress on intergranular corrosion of AA2024-T3  

International Nuclear Information System (INIS)

The effect of uniaxial tensile stress on intergranular corrosion (IGC) of AA2024-T3 was studied using the foil penetration technique. Standard ASTM G49 fixed-displacement jigs were modified to allow the use of sheet samples, which were then attached to an electrochemical cell as in the foil penetration setup. The time for IGC to penetrate samples of varying thickness was monitored. This method provides a new approach to bridge the gap between IGC and intergranular stress corrosion cracking (IGSCC). Samples with various orientations relative to the rolling direction were studied in 1.0 M NaCl at controlled anodic potentials. Potentiodynamic polarization measurements indicated that the two breakdown potentials typically observed for AA2024-T3 were lower for stressed samples than for unstressed samples, and the current at a given potential was higher. The penetration rate depended on potential and was higher for stressed ...

2004-02-01

103

Federal Facility Agreement plans and schedules for liquid low-level radioactive waste tank systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

Although the Federal Facility Agreement (FFA) addresses the entire Oak Ridge Reservation, specific requirements are set forth for the liquid low-level radioactive waste (LLLW) storage tanks and their associated piping and equipment, tank systems, at ORNL. The stated objected of the FFA as it relates to these tank systems is to ensure that structural integrity, containment and detection of releases, and source control are maintained pending final remedial action at the site. The FFA requires that leaking LLLW tank systems be immediately removed from service. It also requires the LLLW tank systems that do not meet the design and performance requirements established for secondary containment and leak detection be either upgraded or replaced. The FFA establishes a procedural framework for implementing the environmental laws. For the LLLW tank systems, this framework ...

1992-03-01

104

Destruction of organic chemicals in Hanford HLW tanks by radiolytic and chemical aging  

International Nuclear Information System (INIS)

The underground storage tanks at the Hanford Complex contain mixed wastes generated over many years from plutonium production and recovery processes. The chemical changes of the organic materials used in the extraction processes and disposed to the tanks have a direct bearing on several specific safety issues, including potential energy releases from these tanks. This paper will give details of a study that is directed towards elucidating thermal and radiological decomposition mechanisms and products of the organic contents of the tanks. The study is being conducted in two parts. The first part, an aging study, will determine kinetics and products of the degradation of a simulated waste subjected to #gamma#-radiation from an external source. Although the simulant will not contain radioactive elements, it will contain other representative inorganic compounds and the primary organic compounds thought to ...

1994-08-21

107

1996 Hazardous Substances and New Organisms No. 30  

Wastenet

ii) Flammability: (iii) A capacity to oxidise: (iv) Corrosiveness: (v) Toxicity (including chronic ...an explosion or fire: (d) For substances with corrosive properties: (i) To reduce the ...likelihood of any unintended corrosion:(ii) To control the adverse effects of any corrosion:

108

Scratch and Corrosion Resistance of an Aluminum Flange with an Electron Beam Modified Seal Edge  

Science.gov (United States)

Scratch and Corrosion Resistance of an Aluminum Flange with an Electron Beam Modified Seal Edge

2011-01-01

109

Metals and alloys : atmospheric corrosion testing : General requirements for field tests  

CERN Document Server

Metals and alloys : atmospheric corrosion testing : General requirements for field tests

1992-01-01

111

Corrosion resistance of modern austenitic-ferritic (duplex) stainless steel. Corrosion of special types. (Review)  

International Nuclear Information System (INIS)

Recent data on resistance of modern corrosion-resistant austenitic-ferritic steels to different types of corrosion are generalized. It is shown that these steels are characterized by high resistance to general corrosion in acid, alkali, chloride and other solutions, are not inclined to intercrystalline, pitting and crevice corrosion and are noted for high resistance to corrosion cracking and corrosion fatigue. All this is combined with technological and economical effectiveness. It is advisible to use these steels instead of highly-alloyed and expensive steels and alloys in chemical, power and other industries. 59 refs.; 2 tabs.

112

CORROSION RESISTANCE OF CHROMIUM CARBIDE-BASE ...  

Science.gov (United States)

... FIELD CORROSION TESTS WERE MADE DURING THE VOYAGES OF THE SCIENTIFIC-RESEARCH SHIPS ACADEMICIAN VERNADSKII AND ...

113

Pitting corrosion  

International Nuclear Information System (INIS)

Pitting corrosion is a kind of electrolytic corrosion by which the surface of a material is locally affected owing to inhomogeneities on the part of the material or medium. The paper deals briefly with questions relating to the importance, to parameters medium or materialwise, influence on production and construction, as well as the general conditions for pitting corrosion. In particular oxygen corrosion in unalloyed and low-alloy steel, and pitting corrosion in ferritic chromium-steel and austenitic chromium-nickel (molybdenum) steel is described. (DG).

114

Corrosion in power plant condensers  

International Nuclear Information System (INIS)

A historical overview of corrosion problems found in power plant condensers and mitigation procedures is presented. The paper is organized according to alloy type and failure mode. Alloys considered are copper-base alloys, stainless steels and titanium. Failure modes discussed include erosion-corrosion, sulfide attack, environmentally assisted cracking, galvanic corrosion, steam condensate corrosion, pitting corrosion, and dealloying. Mitigation procedures discussed include cathodic protection, ferrous ion injection, as well as tube cleaning and layup practices.

115

Operational experiences with cathodic protection of Statoil's main onshore pipelines: a description of the online monitoring systems  

Energy Technology Data Exchange (ETDEWEB)

Statoil is operating an increasing number of offshore and onshore pipelines in the North Sea area and elsewhere. Cathodic protection is a significant part of the corrosion management for these lines and we have collected a significant amount of experience with respect to design and operation of the systems. This paper deals with our comprehensive program for the onshore cathodic protection systems and the various challenges in different countries with respect to technical matters, such as operating conditions and different terrain. Generally, the systems are based on automatically controlled rectifier systems with a wide range of current drainage and very comprehensive monitoring of potentials and current flowing. The use of coupons, polarisation cells and buried reference cells are essential, as well as the use of intensive measurements along the route. The use of online monitoring of selected test posts and all rectifier ...

1999-07-01

116

Corrosion and indices of operating reliability of steam-water circuits of foreign NPP  

Energy Technology Data Exchange (ETDEWEB)

Corrosion failures in circuits of foreign NPPs are considered. According to American statistics there are more corrosion failures in two-circuit NPPs than in NPPs with one circuit. Steam generators mostly suffer from ''corrosion denting''. Lately pitting corrosion becomes a potentially serious problem. Steam generator vertical tubes are mainly subjected to this corrosion type. Attention is drawn to intercrystalline corrosion. The causes of corrosion are described. The problem of optimization of structural materials is discussed to reduce corrosion failures as well as other methods of decreasing corrosion failures. Organization of nondestructive testing, increased requirements to water and steam purity are of great importance.

1983-12-01

117

Terra Nova tow-out poised as next East Coast event  

Energy Technology Data Exchange (ETDEWEB)

This spring, Newfoundland will send off a floating production, storage and offloading (FPSO) vessel to the offshore Terra Nova field. The Terra Nova will proceed southeast through Bull Arm, then northeast out of Trinity Bay, then heads southeast to the Jeanne d'Arc Basin on the Grand Banks. The Terra Nova is expected to produce 115,000 barrels of oil per day for six years, when it reaches full capacity. The consortium, headed by Petro-Canada as senior ownership partner and operator, built an environment protection program into every aspect of the project. Some of the features of the environment protection program include glory holes excavated on the ocean floor for the protection of production equipment from icebergs, to a flare stack on the platform, which has four legs to provide stability in rough seas. The FPSO was designed to withstand sea ice, icebergs, and severe winter storms. Flow lines are also protected, and in the event that a line is damaged, sea water will leak ...

2001-01-15

118

Combination of admixtures to improve the robustness of high-volume fly ash concrete in hot weather[ACI SP-239  

Energy Technology Data Exchange (ETDEWEB)

A precise admixtures system is needed when using high-volume fly ash concrete as fresh concrete occasionally undergoes rapid slump loss after mixing, which can cause problems with casting, pumping and finishing of the concrete in hot weather. This paper provided details of a study conducted to implement high-volume fly ash concrete technology in India. Different families of admixtures were investigated to determine their water reduction capacities. A set-retarding admixture was used in some of the concrete mixtures in order to determine its efficacy. An Indian Portland cement was used to create a total of 22 different concrete mixtures. Four different fly ashes were used to replace portions of the concrete. The slump of the fresh concrete mixture was monitored for 2 to 3 hours. Unit weight and temperature of the concrete was measured. Specimens were cast in steel moulds in order to determine the compressive strength and unit weight of the hardened concrete. The ...

2006-07-01

119

Advanced organic analysis and analytical methods development: FY 1995 progress report. Waste Tank Organic Safety Program  

Energy Technology Data Exchange (ETDEWEB)

This report describes the work performed during FY 1995 by Pacific Northwest Laboratory in developing and optimizing analysis techniques for identifying organics present in Hanford waste tanks. The main focus was to provide a means for rapidly obtaining the most useful information concerning the organics present in tank waste, with minimal sample handling and with minimal waste generation. One major focus has been to optimize analytical methods for organic speciation. Select methods, such as atmospheric pressure chemical ionization mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry, were developed to increase the speciation capabilities, while minimizing sample handling. A capillary electrophoresis method was developed to improve separation capabilities while minimizing additional waste generation. In addition, considerable emphasis has been placed on developing a rapid screening tool, based on Raman and ...

1995-09-01

120

Biology and Monitoring of Diamondback Terrapins in the Chesapeake Bay  

Science.gov (United States)

... to maintaining healthy terrapin populations in the Chesapeake. Biology and Monitoring of Diamondback Terrapins in the Chesapeake ... ...

121

Pitting corrosion of nickel base alloys in halide media  

International Nuclear Information System (INIS)

A computerized corrosion measuring system (EG and G model 350 A) was used to study the influence of Cr, Mo, Ti, Nb and W on the pitting corrosion of nickel base alloys in 3% NaCl at 90"0C. The electrochemical parameters under investigation are the corrosion potential E_c_o_r_r, pitting potential E_p and protection potential E_p_p. The corrosion behaviour of nickel base alloys were studied by using pitting scan and potentiostatic techniques. Values of corrosion potential, pitting potential and protection potential were used for a ranking of alloys for corrosion resistance.

1988-03-06

122

Field Studies of the Electrical Properties of Permeable Reactive Barriers for Monitoring Barrier Aging  

Science.gov (United States)

Permeable reactive barriers (PRB) are a promising technology for the remediation of groundwater containing a range of organic and inorganic contaminants. Although there are number of different types of reactive barriers, some of the most important are constructed from granular zero valent iron (ZVI). One challenge in the large- scale, long-term implementation of PRBs is to monitor the change in barrier properties over time. For example, mineral precipitates can reduce the effectiveness of the barrier by either insulating the reaction surfaces of the ZVI particles and/or by filling the pore space in the barrier and thus reducing its hydraulic permeability. Previous research has shown that resistivity and induced polarization (IP) measurements are sensitive to corrosion and precipitation due to redox reactions between ions in solution and the ZVI mineral surface. New field studies, supported by additional laboratory studies appear to confirm ...

2006-12-01

123

Development of a solvent extraction process for cesium removal from SRS tank waste  

International Nuclear Information System (INIS)

An alkaline-side solvent extraction process was developed for cesium removal from Savannah River Site (SRS) tank waste. The process was invented at Oak Ridge National Laboratory and developed and tested at Argonne National Laboratory using singlestage and multistage tests in a laboratory-scale centrifugal contactor. The dispersion number, hydraulic performance, stage efficiency, and general operability of the process flowsheet were determined. Based on these tests, further solvent development work was done. The final solvent formulation appears to be an excellent candidate for removing cesium from SRS tank waste.

2001-06-30

124

Chemical compatibility study of Cooley L18KU, Herculite, and Elephant Mat with Hanford tank waste  

Energy Technology Data Exchange (ETDEWEB)

An independent chemical compatibility review of various wrapping and absorbent/padding materials was conducted to evaluate resistance to chemicals and constituents present in liquid waste from the Hanford underground tanks. These materials will be used to wrap long-length contaminated equipment when such equipment is removed from the tanks and prepared for transportation and subsequent disposal or storage. The materials studied were Cooley L18KU, Herculite, and Elephant Mat. The study concludes that these materials are appropriate for use in this application.

1998-06-23

125

Anaerobic fermenter-decanter for the purification of residual water from sugar refineries, with recovery of combustible methane  

Energy Technology Data Exchange (ETDEWEB)

An anaerobic fermenter-decanter for the purification of residual water from the sugar industry, with recovery of methane, consists of a tank with inclined walls, with a central agitator on a vertical shaft. A flexible cover anchored by its periphery to the walls of the tank and totally submerged forms a collecting pocket for the fermentation gases. The water to be purified is introduced, after being heated to about 35, towards the bottom of the tank near the agitator. A metal collecting bell with submerged edges and with the shaft of the agitator passing axially through it is connected by its edges to a central opening of the cover. The purification yields may exceed 90%.

1981-10-06

126

Vented Bomb Tests to Characterize Propellant and ...  

Science.gov (United States)

... Two types of combustible cartridge cases, post impregnated (PI) and beater additive (B/A) are available for the 120 mm tank gun system. ...

1990-08-01

127

The solubilities of significant organic compounds in HLW tank supernate solutions  

International Nuclear Information System (INIS)

Large quantities of organic chemicals used in reprocessing spent nuclear-fuels at the Hanford Site have accumulated in underground high-level radioactive waste tanks. The organic content of these tanks must he known so that the potential for hazardous reactions between organic components and sodium nitrate/nitrite salts in the waste can he evaluated. The solubilities of organic compounds described in this report will help determine if they are present in the solid phases (salt cake and sludges) as well as the liquid phase (interstitial liquor/supernate) in the tanks. The solubilities of five significant sodium salts of carboxylic acids and aminocarboxylic acids [sodium oxalate, formate, citrate, nitrilotriacetate (NTA) and ethylendiaminetetraacetate (EDTA)] were measured in a simulated supernate solution at 25 degrees C, 30 degrees C, 40 degrees C, and 50 degrees C.

1994-08-21

128

Tanks Versus Infantry in a Smoke Environment (TISE)  

Science.gov (United States)

... INFANTRY PARTIPI ACT 278 DATA POINTS 60 48 ... Page 21. 29 TISE HISTOGRAN-CUN CURUE INFANTRY PARTIP2 EST 895 DATA POINTS ...

1978-08-01

129

Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan  

Energy Technology Data Exchange (ETDEWEB)

This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.

2000-04-10

130

Root Cause Analysis, Tank Fire Problem, M1A1 Main Battle ...  

Science.gov (United States)

... ammunition is stored. Combustible cartridge cases could absorb moisture, swell, and not chamber properly. Additionally, moisture ...

1989-02-01

131

Results of 1995 characterization of Gunite and Associated Tanks at Oak Ridge National Laboratory, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

This technical memorandum (TM) documents the 1995 characterization of eight underground radioactive waste tanks at Oak Ridge National Laboratory (ORNL). These tanks belong to the Gunite and Associated Tanks (GAAT) operable unit, and the characterization is part of the ongoing GAAT remedial investigation/feasibility study (RI/FS) process. This TM reports both field observations and analytical results; analytical results are also available from the Oak Ridge Environmental Information System (OREIS) data base under the project name GAAT (PROJ-NAME = GAAT). This characterization effort (Phase II) was a follow-up to the {open_quotes}Phase I{close_quotes} sampling campaign reported in Results of Fall 1994 Sampling of Gunite and Associated Tanks at the Oak Ridge National Laboratory, Oak Ridge, Tennessee, ORNL/ER/Sub/87-99053/74, June 1995. The information contained here should be used in conjunction with that ...

1996-02-01

132

Petroleum storage tank cleaning using commercial microbial culture products  

Energy Technology Data Exchange (ETDEWEB)

The removal of paraffinic bottom accumulations from refinery storage tanks represents an increasingly costly area of petroleum storage management. Microorganisms can be used to reduce paraffinic bottoms by increasing the solubility of bottom material and by increasing the wax-carrying capacity of carrier oil used in the cleaning process. The economic savings of such treatments are considerable. The process is also intrinsically safer than alternative methods, as it reduces and even eliminates the need for personnel to enter the tank during the cleaning process. Both laboratory and field sample analyses can be used to document changes in tank material during the treatment process. These changes include increases in volatile content and changes in wax distribution. Several case histories illustrating these physical and chemical changes are presented along with the economics of treatment.

1995-12-31

133

Management of petroleum underground storage tanks at the Hanford Site  

International Nuclear Information System (INIS)

This report represents the timetables, responsible organizations, and methods required to comply with the newly promulgated Washington Administrative Code (WAC) 173-360 Underground Storage Tank (UST) Regulations which became effective December 29, 1990. This report only addresses UST systems that contain nonradioactive material. A total of 84 tanks at the Hanford Site are currently regulated under WAC 173-360. In addition, 32 regulated tanks have been removed as a result of the federally mandated program and the newly implemented state regulations. The majority of the USTs at the Hanford Site are operated by Westinghouse Hanford; however, one is operated by Kaiser Engineers Hanford (KEH) and one by Pacific Northwest Laboratory (PNL).

1991-09-08

134

Influence of anchor behaviour on the earthquake response of liquid storage tanks  

International Nuclear Information System (INIS)

The dynamic response of thin liquid storage tanks to earthquakes is a very complicated phenomenon, because it can be highly non linear. Among others, one can meet material and geometric non linearities of the tank shell leading eventually to static or dynamic buckling non linear behavior of anchor bolts, contact non-linearities due to the uplift of the tank base and to the unilateral character of the fluid pressure on the shell and high amplitude fluid oscillations. Moreover, linear or non linear soil structure interaction affects considerably the response of the fluid structure system under consideration. In this paper we focus attention on problems related only to the base uplift and anchors plastification. We study a tank similar to the Hualien project tank, but we neglect the soil structure interaction. The studied tank is representative of medium height to ...

135

Handbook on Ground Forces Attrition in Modern Warfare  

Science.gov (United States)

... 129 US Armored Division Casualty and Tank Loss Rates ..... 132 British Casualty and rank Loss Rates in Operation "Goodwood" . 134 Page 5. ...

1986-09-01

136

Fish waste - NASA Quest  

Science.gov (United States)

Seriously, generally fish waste does drop, but quite slowly. But a good group of snails should still do a fine job of cleaning the tank. ...

137

Demonstration experiments of volume measurement technique for large scale input accountancy tank  

International Nuclear Information System (INIS)

Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)

2000-12-07

138

Electrochemical properties of passive films on 440C stainless steel. Ph. D. Thesis  

Energy Technology Data Exchange (ETDEWEB)

Type 440C stainless steel is a high-C, high-Cr martensitic steel used in applications requiring high hardness and wear resistance in combination with moderate corrosion resistance. Typical applications include precision aerospace bearings and critical components in computer disk drives. The properties of passive films formed on 440C steel were investigated using advanced electrochemical techniques with a view to establishing a method to measure film stability directly in the passivation baths. Electrochemical measurements were sensitive to the passive film properties and were able to quantify the effect of cooling rate on passive film stability. The techniques used included linear polarization, AC impedance, small amplitude cyclic voltammetry, and coulostatic transient measurements. These provided results that exhibited excellent agreement with the AC impedance technique providing the most information about the interfacial reactions. It was found that the full ...

1990-10-01

139

Corrosion problems and resistance to corrosion of materials for production of steam generators for light water reactor power plants. [Alloys I-600, I-800, I-690  

Energy Technology Data Exchange (ETDEWEB)

Briefly described is knowledge of crevice corrosion, corrosion cracking and denting. In evaluating the corrosion resistance of steam generator materials it is necessary to distinguish corrosion problems caused by the primary coolant side and by the secondary circuit side. At present tubes are manufactured of 7 austenitic alloys of a different chemical composition, and available information shows that views on their corrosion resistance differ. Greatest attention has been devoted to corrosion cracking in the presence of NaOH. Findings related to I-600, I-800, I-690 and AISI 316 are given. Corrodibility by sulfur-containing products is now being studied, namely the intercrystalline corrosion cracking caused by the presence of H/sub 2/S/sub 4/O/sub 6/. Knowledge gained in this respect is summed up.

1984-07-01

140

Corrosion problems and resistance to corrosion of materials for production of steam generators for li.ght water reactor power plants  

International Nuclear Information System (INIS)

Briefly described is knowledge of crevice corrosion, corrosion cracking and denting. In evaluating the corrosion resistance of steam generator materials it is necessary to distinguish corrosion problems caused by the primary coolant eide and by the secondary circuit side. At present tubes are manufactured of 7 austenitic alloys of a different chemical composition, and available information shows that views on their corrosion resistance differ. Greatest attention has been devoted to corrosion cracking in the presence of HaOH. Findings related to I-600, I-800, I-690 and AISI 316 are given. Corrodibility by sulfur-containing products is now being studied, namely the intercrystalline corrosion cracking caused by the presence of H_2S_4O_6. Knowledge gained in this respect is summed up. (J.P.).

141

Corrosion in steam generators of PWR type nuclear power plants  

International Nuclear Information System (INIS)

Problems are discussed of heat exchange tubes of Westinghouse type vertical steam generators exhibiting corrosion damage such as point corrosion, planar corrosion, tube denting, corrosion stress cracking, crevice corrosion, fretting corrosion and intergranular corrosion. Attention is also paid to problems of WWER-440 type horizontal steam generators, where the level fluctuation area is critical; noncompact porous deposits of the corrosion products give rise to crevice effects and cause significant concentration of chloride ions and other additions. This problem can be partly resolved by a modification of the collector design at the level variation area. An additional measure is the production of steel 08Kh18N10T with a very low level of harmful elements and inclusions. (Z.M.). 3 figs., 11 refs.

1988-03-01

142

Thermogalvanic effects on the pitting corrosion of water-cooled heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

Thermogalvanic corrosion of St3 steel in a temperature range from 25 to 50{degrees}C with a 3.84{degrees}C/cm gradient was studied in a neutral media flow. It is shown that the thermogalvanic effect on the pitting corrosion of water-cooled heat exchangers is decisive but dual. Depending on the composition of the cooling medium, thermogalvanic corrosion may either enhance (0.5 M NaCl) or inhibit (tap water) pitting corrosion.

1995-05-01

143

Pitting corrosion resistance of silicon-implanted stainless steels  

International Nuclear Information System (INIS)

The pitting corrosion resistance of three different types of stainless steel implanted with silicon is investigated using the potentiokinetic polarization technique. The specimens are tested in 3% NaCl and 0.1 N HCl solutions. Silicon ion implantation inhibits pitting corrosion of the steels in both aqueous media. The corrosion resistance depends on the silicon dose. Post implantation annealing only slightly alters the localized corrosion. (author).

144

Improvement of PWR reliability by corrosion prevention  

Energy Technology Data Exchange (ETDEWEB)

Since first PWR in Japan started commercial operation in 1970, we have encountered the various modes of corrosion on primary and secondary side components. We have paid much efforts for resolving these corrosion problems, that is, investigating the causes of corrosion and establishing the countermeasures for these corrosion. We summarize these efforts in this article. (author)

1999-12-01

145

Hydrodynamic measurement of a single corrosion pit  

Energy Technology Data Exchange (ETDEWEB)

The hydrodynamics of gas evolution plays an important role in the pitting corrosion of metals. A new technique for the measurement of the local hydrodynamics caused by corrosion processes, using the atomic force microscope, has been presented in this work. The hydrodynamics of hydrogen evolution on Al surface due to pitting corrosion was studied. The characteristic features of the hydrodynamics are discussed. To the best of our knowledge this is the first local measurement of pitting corrosion hydrodynamics.

2004-11-01

146

Effect of aging on the pitting corrosion behavior in Al-Li alloys  

Energy Technology Data Exchange (ETDEWEB)

In the present work, electrochemical measurements and corrosion tests in NaCl solutions were carried out to study the effect of aging treatments on pitting corrosion behavior in a 8090 alloy and its high purity Al-Li binary alloy analogue. The pitting corrosion characteristics and corrosion resistance of the 8090 alloy have been determined in relation to precipitation microstructures. (orig.).

1990-06-01

147

GASVOL 18'' gas pipeline - risk based inspection study  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a risk based approach and inspection planning as part of the Pipeline Integrity Management (PIM) system for the 95.5 km long 18'' GASVOL gas pipeline in the South eastern region of Brazil transporting circa 5 000 000 m3 dry gas per day. Pipeline systems can be subject to several degradation mechanisms and inspection and monitoring are used to ensure system integrity. Modern pipeline regulations and codes are normally based on a core safety or risk philosophy. The detailed design requirements presented in design codes are practical interpretations established so as to fulfill these core objectives. A given pipeline, designed, constructed and installed according to a pipeline code is therefore the realization of a structure, which, along its whole length, meets the applicable safety objectives of that code. The main objective of Pipeline Integrity Management (PIM) is to control and document the integrity of the pipeline for its ...

2003-07-01

148

Corrosion behaviour of non-ferrous metals in sea water  

Energy Technology Data Exchange (ETDEWEB)

The most typical kinds of corrosion of brasses are selective corrosion (dezincification) and stress corrosion. Prevention against these kinds of corrosion lies in application of arsenic alloy addition and appropriate heat treatment removing internal stresses as well as in maintaining the arsenic and phosphorus contents on a proper level. The most typical corrosion of cupronickels is the local corrosion. Selective corrosion occurs less often and corrosion cracking caused by stress corrosion in sea water does not usually occur. Crevice corrosion is found especially in places of an heterogeneous oxidation of the surface under inorganic deposits or under bio-film. Common corrosive phenomena for brasses and cupronickels are the effects caused by sea water flow and ...

2004-07-01

149

The influence of yttrium (Y) on the corrosion of Mg-Y binary alloys  

International Nuclear Information System (INIS)

Research highlights: #-># The Y-intermetallic can accelerate corrosion and Y can increase the protectiveness of the surface layer. #-># In 0.1 M NaCl, the corrosion rate of Mg-Y alloys increased with increasing Y due to the Y intermetallic. #-># In 0.1 M NaCl, there was filiform corrosion. #-># In 0.1 M Na_2SO_4, the corrosion rate of Mg-Y alloys decreased with increasing Y in the range 3-7%Y. #-># Hydrogen evolution was observed from particular parts of the alloy surface. - Abstract: Corrosion of Mg-Y alloys was studied using electrochemical evaluations, immersion tests and direct observations. There were two important effects. In 0.1 M NaCl, the corrosion rate increased with increasing Y content due to increasing amounts of the Y-containing intermetallic. In 0.1 M Na_2SO_4, the corrosion rate decreased with increasing Y ...

2010-11-01

150

Effect of oxygen and oxidizing ions on denting corrosion  

International Nuclear Information System (INIS)

Information is presented concerning solute concentration in a porous layer; solute concentration in a packed crevice; corrosion of a packed carbon steel crevice in NaCl-O"2 solutions; and effect of copper on corrosion in NaCl-O"2 solutions.

1983-01-01

151

Corrosion and histopathological studies on anode materials for implantable power sources. [In vivo corrosion studies on anode material  

Science.gov (United States)

The biocompatibility and corrosion resistance of various materials for use as sacrificial anodes in in vivo hybrid fuel cells were studied. Aluminium, zinc, and magnesium alloy AZ31B were studied, and the results are discussed.

1974-01-01

152

Atmospheric corrosion in Gran Canaria specifically meteorological and pollution conditions.  

Science.gov (United States)

Carbon steel, copper, zinc and aluminium samples were exposed in different sizes with known ambient parameters in Gran Canaria Island and atmospheric corrosion was investigated. Weight-loss measurements used to determine corrosion damage were complemented...

1998-01-01

153

46 CFR 160.171-17 - Approval testing for adult size immersion suit.  

Science.gov (United States)

...visible damage. (k) Corrosion resistance. Each metal part of a...evidence of salt-spray corrosion resistance equal to or greater than...sample of test metal must show corrosion resistance equal to or better than...

2010-10-01

154

W-12 valve pit decontamination demonstration  

Energy Technology Data Exchange (ETDEWEB)

Waste tank W-12 is a tank in the ORNL Low-Level Liquid Waste (LLLW) system that collected waste from Building 3525. Because of a leaking flange in the discharge line from W-12 to the evaporator service tank (W-22) and continual inleakage into the tank from an unknown source, W-12 was removed from service to comply with the Federal Facilities Agreement requirement. The initial response was to decontaminate the valve pit between tank W-12 and the evaporator service tank (W-22) to determine if personnel could enter the pit to attempt repair of the leaking flange. Preventing the spread of radioactive contamination from the pit to the environment and to other waste systems was of concern during the decontamination. The drain in the pit goes to the process waste system; therefore, if high-level liquid waste were generated during decontamination activities, it would ...

1995-12-01

155

Realistic Probability Estimates For Destructive Overpressure Events In Heated Center Wing Tanks Of Commercial Jet Aircraft  

Energy Technology Data Exchange (ETDEWEB)

The Federal Aviation Administration (FAA) identified 17 accidents that may have resulted from fuel tank explosions on commercial aircraft from 1959 to 2001. Seven events involved JP 4 or JP 4/Jet A mixtures that are no longer used for commercial aircraft fuel. The remaining 10 events involved Jet A or Jet A1 fuels that are in current use by the commercial aircraft industry. Four fuel tank explosions occurred in center wing tanks (CWTs) where on-board appliances can potentially transfer heat to the tank. These tanks are designated as ''Heated Center Wing Tanks'' (HCWT). Since 1996, the FAA has significantly increased the rate at which it has mandated airworthiness directives (ADs) directed at elimination of ignition sources. This effort includes the adoption, in 2001, of Special Federal Aviation Regulation 88 of 14 CFR part 21 ...

2007-02-07

156

Operational test report integrated system test (ventilation upgrade)  

Energy Technology Data Exchange (ETDEWEB)

Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.

1999-10-05

157

Inventory of Tank Farm equipment stored or abandoned aboveground  

Energy Technology Data Exchange (ETDEWEB)

This document provides an inventory of Tank Farm equipment stored or abandoned aboveground and potentially subject to regulation. This inventory was conducted in part to ensure that Westinghouse Hanford Company (WHC) does not violate dangerous waste laws concerning storage of potentially contaminated equipment/debris that has been in contact with dangerous waste. The report identifies areas inventoried and provides photographs of equipment.

1994-10-12

158

Implementation guide for Hanford Tanks Initiative C-106 heel retrieval contract management HNF-2511  

Energy Technology Data Exchange (ETDEWEB)

This report is an Implementation Guide for Hanford Tanks Initiative C-106 heel retrieval contract management HNF-2511 to provide a set of uniform instructions for managing the two contractors selected. The primary objective is to produce the necessary deliverables and services for the HTI project within schedule and budget.

1998-04-17

159

High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 2  

Energy Technology Data Exchange (ETDEWEB)

The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Document (S/RID) is contained in multiple volumes. This document (Volume 2) presents the standards and requirements for the following sections: Quality Assurance, Training and Qualification, Emergency Planning and Preparedness, and Construction.

1994-04-01

160

Development of an experimental installation for short-lived isotopes production in INR linac  

International Nuclear Information System (INIS)

A possibility of short-lived isotopes production in inter-tank section between the first and the second drift tube tanks (20.45 MeV) in INR linac is considered. At the initial stage the main efforts are concentrated on production of fluorine-18 used for positron emission tomography. The results of beam forming calculations, target heating calculations, equipment activation calculations as well as installation configuration and design are presented.

2010-01-01

161

DOUBLE-SHELL TANK (DST) HYDROXIDE DEPLETION MODEL FOR CARBON DIOXIDE ABSORPTION  

International Nuclear Information System (INIS)

This document generates a supernatant hydroxide ion depletion model based on mechanistic principles. The carbon dioxide absorption mechanistic model is developed in this report. The report also benchmarks the model against historical tank supernatant hydroxide data and vapor space carbon dioxide data. A comparison of the newly generated mechanistic model with previously applied empirical hydroxide depletion equations is also performed.

2009-04-30

162

The use of different techniques for determination of pitting corrosion potential of austenitic stainless steel  

International Nuclear Information System (INIS)

Three different techniques for pitting corrosion potential measurement on austenitic stainless steel (Fe18Cr10Ni) were compared: conventional polarization method, a new Avesta electrochemical corrosion measurement cell and a scratch technique. Special attention was paid to the effects of crevice corrosion during pitting corrosion potential measurement and to their elimination. Development of a rapid test technique for reliable pitting corrosion potential determination was aimed at and resulted from comparison of the different techniques.

1991-07-01

163

Pitting corrosion of copper and copper alloys. (Latest citations from the EI Compendex*plus database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning the pitting corrosion of copper and copper alloys by different media, with some references to methods that protect against such corrosion. Included are factors contributing to the onset of pitting corrosion. Emphasis is placed on exposure to water, especially in heat exchanger tubing and water conduits. Studies are included which examine corrosion in metals containing small amonts of copper where corrosion is attributable to changes in alloying. (Contains a minimum of 158 citations and includes a subject term index and title list.)

1994-04-01

164

Neural network for prediction of superheater fireside corrosion  

Energy Technology Data Exchange (ETDEWEB)

Superheater corrosion causes vast annual losses to the power companies. If the corrosion could be reliably predicted, new power plants could be designed accordingly, and knowledge of fuel selection and determination of process conditions could be utilized to minimize superheater corrosion. If relations between inputs and the output are poorly known, conventional models depending on corrosion theories will fail. A prediction model based on a neural network is capable of learning from errors and improving its performance as the amount of data increases. The neural network developed during this study predicts superheater corrosion with 80 % accuracy at early stage of the project. (orig.) 10 refs.

1998-12-31

165

Evaluation of the corrosion and corrosion-mechanical damage of the primary piping material of WWER-440/V213c units in operating conditions  

International Nuclear Information System (INIS)

The sensitivity of the primary circuit material was examined at the Mochovce and Dukovany NPPs. No significant sensitivity of the base material or the weld metal to the initiation of corrosion cracking was observed. Thermal aging was found to accelerate significantly the corrosion fatigue kinetics in the material of the heat affected zone. The threshold values of the double amplitudes of the stress intensity factor were below 8 MPa/m"2 for the materials examined, with a cycle asymmetry coefficient of 0.65. The tests revealed no appreciable sensitivity to general corrosion, pitting, or intergranular corrosion. (J.B.). 7 tabs., 26 figs., 11 refs.

166

Corrosion of hardened cement paste by acetic and nitric acids; Part 1: Calculation of corrosion depth  

Energy Technology Data Exchange (ETDEWEB)

The rate of corrosion of hardened cement paste in solutions of nitric, hydrochloric, sulfuric, acetic and formic acids was compared. Corrosion in solutions of acetic and nitric acids with different concentrations was studied in more detail. The results made it possible to obtain the relationships expressing the influence of concentration and the time of action of acid solutions on the depth of corrosion. The rates of corrosion in nitric acid solutions during the first 3 years were about 2 to 4 times that in acetic acid solutions, depending on the concentration.

1994-01-01

167

Corrosion and reliability of PWR power plants  

International Nuclear Information System (INIS)

Corrosion is increasingly becoming an important factor reducing the reliability of many nuclear power plant components. The significance is evaluated of corrosion phenomena with respect to the reliability of primary circuit components of LWR's, viz., the reactor pressure vessel, primary piping, steam generator, and fuel elements. The mechanism of corrosion phenomena is explained and methods of minimizing their effects are presented. An analysis is made of the needs to solve the corrosion problems of nuclear power plants from the point of view of Czechoslovak producers and research and development activities. International cooperation is reviewed and main problems are formulated on which the solution of corrosion problems of structural materials used in WWER type nuclear power plants should be focussed. (author).

168

Atmospheric corrosion in Gran Canaria specifically meteorological and pollution conditions  

Energy Technology Data Exchange (ETDEWEB)

Carbon steel, copper, zinc and aluminium samples were exposed in different sizes with known ambient parameters in Gran Canaria Island and atmospheric corrosion was investigated. Weight-loss measurements used to determine corrosion damage were complemented with metallographic and XP S determination in order to characterize the structure and morphology of surface corrosion products. The ambient aggressiveness could be well evaluated from meteorological and pollution data. All atmospheric corrosion and environmental data were statistically processed for establishing general corrosion damage functions for carbon steel, copper, aluminium and zinc in terms of Gran Canaria extreme meteorological and pollution parameters. (Author)

1998-12-31

169

Timber-Fish-Wildlife (TFW) Monitoring  

Science.gov (United States)

Timber-Fish-Wildlife (TFW) Monitoring http://www.nwifc.wa.gov/TFW/ - a cooperative, inter-agency monitoring effort ... ...

170

Monitoring for adverse drug reactions  

UK PubMed Central (United Kingdom)

Monitoring describes the prospective supervision, observation, and testing of an ongoing process. The result of monitoring provides reassurance that the goal has been or will be achieved, or suggests...Full Text Available

2006-04-01

171

Sodium leak detector  

International Nuclear Information System (INIS)

Purpose: To permit accurate detection of sodium leakage by distinguishing between variations in the overflow tank level due to changes in sodium temperature accompanying changes in the power level or operating state of a liquid metal sodium cooled fast breeder, and a reduction in power level due to duct leakage. Constitution: The volume of sodium in the primary cooling system is roughly estimated from the temperatures of hot and cold legs, and the duct leak preset level with respect to the sodium liquid level within an overflow tank when the plant is normal is varied according to the state of the plant. More particularly, the volume of sodium within the overflow tank is calculated on the basis of a signal representing the liquid level detected by a liquid level gauge in the overflow tank and a signal representing the temperature detected by hot leg and cold leg thermometers, thereby obtaining the preset ...

172

Numerical flow simulation in ship and ocean engineering; Senpaku kaiyo suiri bun`ta deno ryutai suchi simulation  

Energy Technology Data Exchange (ETDEWEB)

The improvement in the functions of the viscous flow calculation method VEGA-SHIP around a ship and the expansion of application range were described as the numerical flow simulation in ship and ocean engineering and at the same time application examples to the ocean engineering by the general-purpose flow simulation code FLOW-3D handling the non-steady flow with a free surface were introduced as the numerical simulation regarding such products as a water gate and a dam. In the VEGA-SHIP, water surface was handled as a fixed wall so that wave could not be calculated. Therefore, an algorithm for calculating wave on the water surface was added to the VEGA-SHIP and a calculation method simultaneously considering the creation of wave around the ship and viscosity was developed. The FLOW-3D was used to calculate the phenomenon where inside liquid moved greatly due to the oscillation of a tank and hit against and damaged the tank ceiling in the ...

1995-01-01

173

Elephant's foot phenomenon in liquid storage tanks  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a method for analyzing the seismic response of a flat bottomed cylindrical liquid storage tank to vertical earthquake excitation. Here, vertical earthquake acceleration is considered to correspond to an increase in the density of a stored liquid. Taking into account the vertical and horizontal earthquake loads, hydrostatic pressure, and considering restrictive moment and shear forces at shell-bottom welded joint, the author has calculated circumferential and longitudinal stresses. These are combined to more accurately approximate the stresses at the base shell course. The calculated result closely conforms to the actual damage, termed ''elephant's foot,'' observed in the fuel storage tanks damaged in the Tangshan earthquake. This result shows that the ''elephant's foot'' phenomenon is not caused by buckling of the ...

1983-01-01

174

The Effect of Morpholine/Boric Acid/Hydrazine Chemistry on ...  

Science.gov (United States)

... the effect of MBH on steam generator crevice corrosion; model boiler test results show that MBH is effective against denting corrosion and Alloy 600 ...

175

INVESTIGATION OF THE CORROSION RESISTANCE OF BS ...  

Science.gov (United States)

... 1. IE1O and IM'15 exposed to field corrosion tests at five sites for periods of 12 and 24 months confirm previous findings. ...

1953-12-01

176

Corrosion experiments and materials developed for the Japanese HLM systems  

British Library Electronic Table of Contents (United Kingdom)

The static corrosion tests in lead-bismuth eutectic (LBE) were conducted from 450degreeC to 600degreeC to understand corrosion behavior and develop corrosion resistant materials for heavy liquid metal systems. While increase of Cr content in steels enhances corrosion resistance in LBE, the effect approaches a constant value above 12wt% of Cr. Corrosion depth in LBE increases with increasing temperature and corrosion attack becomes severe above 550degreeC even under the condition of high oxygen concentration. Nickel dissolution and Pb-Bi penetration occur in 316SS and JPCA above 550degreeC under the condition of high oxygen concentration. When oxygen concentration decreases below the level of Fe oxide formation, corrosion attack on these steels also becomes violent due to dissolution of var...

2011-01-01

177

Corrosion behavior of iron and nickel base alloys in high temperature and pressure water  

International Nuclear Information System (INIS)

In equipment industries, the equipments handling industrial water and pure water are numerous. In power generation including nuclear power generation, water serves as a working medium. Review is made on the experiences in the corrosion of iron and nickel base alloys in high temperature, high pressure water and the results of researches derived from them. Under high temperature and high pressure, carbon steel, low alloy steel, stainless steel and high nickel alloy cause corrosion even in pure water. But in the case of serious corrosion, chlorine, oxygen, alkali and others in water take part. The following matters are described: corrosion by steam; stress corrosion cracking in pure water; corrosion by impurities in high temperature, high pressure pure water, i.e. chlorine ions, dissolved oxygen, and alkali; corrosion under radiation. (J.P.N.).

178

AFSPC Corrosion Control Program - NASA  

Science.gov (United States)

HQ AFSPC/LG / CORR.PPT. 2. 01/16/02. UNCLASSIFIED. UNCLASSIFIED. Overview. " Corrosion Control Areas. " Support Activities. " Test Projects ...

179

A study on the degradation of coating and corrosion of ship`s hull based on the probabilistic approach  

Energy Technology Data Exchange (ETDEWEB)

Corrosion is said to be the most dominant factor which affects the physical life of ships and offshore structures. In order to secure the structural safety of ships and offshore structures, it is necessary to take measures to corrosion based on the prediction of condition of progressive corrosion. But such prediction is difficult because the behavior of corrosion`s progress is probabilistic. In this paper, probabilistic model, which could evaluate the degradation of coatings and the successive corrosion of steel members, was proposed in order to explain the tendency of the actual corrosion conditions of existing ships. Then, statistical inferences on the proposed model were made by applying the actual data on plate thickness measurements of Bulk Carriers` Cargo Hold. And validity of the proposed model was verified.

1996-12-31

180

Corrosion of 304 stainless steel in molten-carbonate fuel cells  

Energy Technology Data Exchange (ETDEWEB)

The corrosion behavior of 304 stainless steel was characterized with cyclic voltammetry in a eutectic Li/K and Li/Na carbonate melt under anode and cathode gas of the molten-carbonate fuel cell (MCFC). The corrosion rate of 304 steel was determined in four different environments of the MCFC with electrochemical methods and from cross-sectional analysis of corrosion layers. These four environments were open-circuit and MCFC-load conditions both under anode and cathode gas. At open-circuit conditions corrosion was more severe under the oxidizing cathode gas then under the reducing anode gas. On the contrary, at load conditions corrosion was more severe under anode than under cathode gas. The anodic polarization under anode gas enhances corrosion, whereas the high anodic polarization under cathode gas leads to anodic protection. Corrosion ...

1999-07-01

181

An evaluation of corrosion resistant alloys by field corrosion test in Japanese refuse incineration plants  

Energy Technology Data Exchange (ETDEWEB)

As the first step for development of the corrosion resistant superheater tube materials of 500 C, 100 ata used in high efficient waste-to-energy plants, field corrosion tests of six conventional alloys were carried out at metal temperatures of 450 C and 550 C for 700 and 3,000 hours in four typical Japanese waste incineration plants. The test results indicate that austenitic alloys containing approximately 80 wt% [Cr+Ni] show excellent corrosion resistance. When the corrosive environment is severe, intergranular corrosion of 40{approximately}200 {micro}m depth occurs in stainless steel and high alloyed materials. It is confirmed quantitatively that corrosion behavior is influenced by environmental corrosion factors such as Cl concentration and thickness of deposits on tube surface, metal temperature, and flue gas temperature. The excellent ...

1995-12-01

182

An evaluation of corrosion resistant alloys by field corrosion test in Japanese refuse incineration plants  

International Nuclear Information System (INIS)

As the first step for development of the corrosion resistant superheater tube materials of 500 C, 100 ata used in high efficient waste-to-energy plants, field corrosion tests of six conventional alloys were carried out at metal temperatures of 450 C and 550 C for 700 and 3,000 hours in four typical Japanese waste incineration plants. The test results indicate that austenitic alloys containing approximately 80 wt% [Cr+Ni] show excellent corrosion resistance. When the corrosive environment is severe, intergranular corrosion of 40#approx#200 microm depth occurs in stainless steel and high alloyed materials. It is confirmed quantitatively that corrosion behavior is influenced by environmental corrosion factors such as Cl concentration and thickness of deposits on tube surface, metal temperature, and flue gas temperature. The excellent ...

1995-03-26

186

Recent environment, energy and resources cases and issues in Alberta  

Energy Technology Data Exchange (ETDEWEB)

Significant environmental issues and regulatory proceedings in Alberta were discussed. The Mackenzie Valley Pipeline Project was reviewed in relation to the Deh Cho First Nation's advanced actions in the federal court to enjoin the review panel from proceeding with the review process. The Deh Cho First Nation is seeking a declaration that the plan violates their rights under the Canadian Charter of Rights and Freedoms and the Constitution Act. Various regulatory and government agencies have now developed a plan to coordinate their different regulatory processes and approvals in the Cooperation Plan for the Environmental Impact Assessment and Regulatory Review of the Northern Gas Pipeline project. The Deh Cho allege that they were not afforded the opportunity to participate in the development and implementation of the plan. A review panel plans to proceed once the environmental and social impacts are determined, and the consortiums plan to minimize harm has been submitted. ...

2005-07-01

187

2007 SB14 Source Reduction Plan/Report  

Energy Technology Data Exchange (ETDEWEB)

Aqueous solutions (mixed waste) generated from various LLNL operations, such as debris washing, sample preparation and analysis, and equipment maintenance and cleanout, were combined for storage in the B695 tank farm. Prior to combination the individual waste streams had different codes depending on the particular generating process and waste characteristics. The largest streams were CWC 132, 791, 134, 792. Several smaller waste streams were also included. This combined waste stream was treated at LLNL's waste treatment facility using a vacuum filtration and cool vapor evaporation process in preparation for discharge to sanitary sewer. Prior to discharge, the treated waste stream was sampled and the results were reviewed by LLNL's water monitoring specialists. The treated solution was discharged following confirmation that it met the discharge criteria. A major source, accounting for 50% for this waste stream, is metal ...

2007-07-24

189

Deployment Support Leading to Implementation  

Energy Technology Data Exchange (ETDEWEB)

The following paragraphs summarize the progress of each research project funded under the WVU Cooperative Agreement during the third quarter of 1997 (July - September 1997). The projects are arranged according to their 1997 WVU task number. WVU Focus Area 1.0: Subsurface Contaminants, Containment and Remediation Task No. 1.1: Project discontinued. Task No. 1.2: Development of Standard Test Protocols and Barrier Design Models for Desiccation Barriers (K. Amininan & S. Ameri): A number of experiments were preformed this period to evaluate the ability of the dried sand-packs to act as a barrier to liquids. Water infiltration tests were done with a constant head, dispersing 80 ml of water, and by adding water in small increments. Results indicate that when the water is spilled over the sand-pack, it has the tendency to channel through the sand-pack, significantly reducing the capacity of the dried zone to retain liquid contaminants. This appears to be largely influenced by particle ...

1997-10-01

190

A.C.R.O. activity report 2002; A.C.R.O. rapport d'activite 2002  

Energy Technology Data Exchange (ETDEWEB)

A.C.R.O. (Association pour le Controle de la Radioactivite dans l Ouest) is a French non governmental organisation that operates a laboratory for radioactivity analysis. It was created in 1986 as a response to people demands for information and reliable, independent testing. The organisation mainly carries out missions of information and training for its correspondents and more generally for a wide audience, particularly for people who worry about problems of environment, health, management of radioactive waste and emissions. Thanks to its structure, it enables citizens to involve themselves together with scientists so as to gain access to information that was hither to reserved to specialists. The organisation can vouchsafe its independence from the diversity of its members and volunteers, as well as from the diversity of its money resources. Besides its headquarters situated on the city of Caen area (Normandy), three branches situated in North Normandy, in Touraine and North Cotentin ...

2002-07-01

191

Titanium Alloys for Medical Instrumentation  

International Science & Technology Center (ISTC)

The New Titanium Alloys With Increased Mechanical Properties and Corrosion Resistance for Medical Instruments and their Coatings

192

Pitting corrosion of metals: A review of the critical factors  

Energy Technology Data Exchange (ETDEWEB)

Pitting corrosion is localized accelerated dissolution of metal that occurs as a result of a breakdown of the otherwise protective passive film on the metal surface. This paper provides an overview of the critical factors influencing the pitting corrosion of metals. The phenomenology of pitting corrosion is discussed, including the effects of alloy composition, environment, potential, and temperature. A summary is then given of studies that have focused on various stages of the pitting process, including breakdown of the passive film, metastable pitting, and pit growth. 120 refs.

1998-06-01

194

Evaluation on corrosion environment at BWRs  

International Nuclear Information System (INIS)

... Systems Research and Development Center, Yokohama, Kanagawa (Japan)

2009-05-01

195

Evaluation of corrosion of dissolver for enriched uranium  

International Nuclear Information System (INIS)

... Hayashi, Shinichiro Japan Atomic Energy Agency, Tokai, Ibaraki (Japan)

2007-10-01

196

Evaluation of corrosion of dissolver for enriched uranium  

International Nuclear Information System (INIS)

... FUEL CYCLE AND FUEL MATERIALS MATERIALS SCIENCE chromium-nickel

2007-10-01

197

EFFECT OF MICROSTRUCTURE ON THE STRENGTH ...  

Science.gov (United States)

... THE STRENGTH, TOUGHNESS, AND STRESS-CORROSION CRACKING SUSCEPTIBILITY OF A METASTABLE BETA TITANIUM ALLOY (Ti-11. ...

1970-02-01

198

Corrosion studies on selected packaging materials for disposal of high level wastes  

International Nuclear Information System (INIS)

In order to qualify corrosion resistant materials for high level waste (HLW) packagings acting as a long-term barrier in a rock salt repository, the corrosion behaviour of the preselected materials Ti 99.8-Pd, Hastelloy C4 and two unalloyed steels was investigated. The resistance of the materials to general corrosion, local corrosion and stress corrosion cracking was examined under postulated accident conditions in the repository by long-term immersion tests of up to 4 years duration and electrochemical methods. The parameters investigated were different salt brines, temperatures of 90 deg. C, 170 deg. C and 200 deg. C as well as a gamma radiation field of 10"3Gy/h (10"5rad/h). Among the materials studied, Ti 99.8-Pd exhibited the highest corrosion resistance. This material corroded at a very low rate (

1987-05-01

200

Corrosion of Cu-W condensates in tap water  

International Nuclear Information System (INIS)

Corrosion resistance of Cu-W system condensates in tap water was studies. It is shown that with an increase in W concentration in the condensates of the Cu-W system their corrosion in tap water enhances. In the material designated for power supply facilities the optimal tungsten content is up to 6%. Owing to formation of oxide film on the surface of the samples corrosion is stabilitized 40 h after the test start.

202

Comparison of Ceramic, Metal and Polymer Crevice Formers on the Crevice Corrosopn Behavior of Ni-CR-Mo Alloy C22  

Energy Technology Data Exchange (ETDEWEB)

A necessary condition for crevice corrosion is that a crevice former create a sufficiently tight, restricted geometry on the metal surface to support the development of critical crevice chemistry. Crevice corrosion is affected by the crevice geometry (tightness) and the properties of the crevice former. The objective of this study is to determine the effect of the crevice former material on the evolution of localized corrosion-damage. A standard crevice corrosion test method is modified by (a) the use of ceramic, metal or polymer materials as the crevice former and (b) the variation of size and shape of the crevice. This study focuses on the post initiation stage of crevice corrosion and addresses factors that may limit the initiation of localized corrosion and also slow or stop the continued propagation of corrosion. Controlled crevice ...

2006-05-08

204

Zirconium for superior corrosion resistance  

International Nuclear Information System (INIS)

Zirconium is a transition element located along with sister elements titanium and hafnium in Group IVB of the periodic table. It is grayish white metal, with a density somewhat less than carbon steel. Zirconium is the ninth most common metallic element in the earth's crust, and is more abundant than zinc, lead, nickel, or even copper. Zirconium is exceptionally resistant to corrosion by many common acids and alkalis. It is resistant to most organic acids, such as formic, acetic, lactic, and oxalic acids. It also has a high resistance to localized forms of corrosion, such as pitting, crevice corrosion, and stress corrosion cracking. Its corrosion resistance is caused by the formation of a dense, tenaciously adherent, chemically inert oxide film on the surface. This oxide film protects the base metal from both chemical and mechanical attack at temperatures up to about 400 C (750 F). ...

205

The effect of heat treatment on the electrochemical corrosion behavior of reactive plasma-sprayed TiN coatings  

British Library Electronic Table of Contents (United Kingdom)

The effect of heat treatment on the corrosion behavior of reactive plasma sprayed TiN coatings in simulated seawater was investigated by electrochemical methods such as the corrosion potential-time curve (Ecorr-t), potentiodynamic polarization, electrochemical impedance spectroscopy (EIS) and SEM, etc. The results showed that the corrosion potential of TiN coatings increased after heat treatment; the corrosion current of the TiN coatings after heat treatment (be hereafter referred to as HT-TiN) was 13.3% of the untreated coatings (be hereafter referred to as UT-TiN), and the polarization resistance of HT-TiN was 20 times of UT-TiN, which indicated that the heat treatment had significantly increased the corrosion resistance of the coatings. The corrosion behavior of the coatings was mainly ...

2011-01-01

206

Investigation of erosion-corrosion of 3003 aluminum alloy in ethylene glycol-water solution by impingement jet system  

British Library Electronic Table of Contents (United Kingdom)

Erosion-corrosion (E-C) of 3003 aluminum (Al) alloy in ethylene glycol-water solutions were studied by weight-loss and electrochemical measurements as well as surface characterization through an impingement jet system. Al alloy E-C is dominated by erosion components, i.e., pure erosion and corrosion-enhanced erosion, which account for 92-97% of the total E-C rate under the various conditions in this work. Contribution from corrosion components, including pure corrosion and erosion-enhanced corrosion, is slight. With the increase of fluid flow velocity and sand concentration, the total E-C rate increases. Compared with the significant increase of the rates of erosion components, the increase of the rate of corrosion component is negligible. Upon fluid flow, passivity of Al alloy that develo...

2009-01-01

207

Influence of silicon, copper and cobalt on corrosion cracking and pitting corrosion in 03Kh18N30 steel  

International Nuclear Information System (INIS)

The effect of alloying low carbon 18Cr-30Ni steel with silicon (up to 5.1%), copper (up to 5.4%), cobalt (up to 15.3%) on the resistance to corrosion cracking and pitting corrosion, is studied. Tests on uniaxial tension are carried out in 42% MgCl_2 solution and gravimetric studies in 10% FeCl_3x6H_2O. It is established that alloying steel of the Kh18N30 type with silicon increases strength and resistance to corrosion cracking. Copper and cobalt decrease a resistance to pitting corrosion but somewhat increase a resistance to corrosion cracking.

208

Corrosion of gold bridgewire in electronic components  

Energy Technology Data Exchange (ETDEWEB)

Accelerated aging tests on gold bridgewired detonator assemblies to determine compatibility of the Au and Pd-In-Sn solder with the organic explosive, PENT, have revealed an unusual corrosion process. These tests, conducted at 74/sup 0/C and 54/sup 0/C indicated a preferential attack of the gold. A matrix of corrosion test units was established to study this corrosion problem with accelerating temperatures up to 100/sup 0/C. Scanning electron microscopy (SEM), energy dispersive x-ray (EDX), and x-ray diffraction techniques were used to determine the extent of the corrosion and identify the corrosion products. Results indicate the preferential attack of the gold was due to HCN formed by decomposition of the explosive powder (PETN) at high temperatures. Other associated reactions were also observed including subsequent attack of the solder by the gold corrosion ...

1986-01-01

209

Corrosion mode diagrams for alloy 690 TT and alloy 800  

Energy Technology Data Exchange (ETDEWEB)

Due to the well-establish corrosion problems of Alloy 600 as a steam-generator material and the subsequent focus on thermally treated (TT) Alloy 690 and Alloy 800 as alternative materials, a systematic analysis of the corrosion behavior of these two latter alloys is warranted. Corrosion test results for Alloys 690 TT and 800 were collected and organized in the form of corrosion mode diagrams. Selected data for mill annealed (MA) Alloy 600 were also included for reference. The corrosion mode diagrams correlate the modes of corrosion degradation observed in tests as functions of the environment pH and electrochemical potential (ECP). The diagrams confirm that Alloys 690TT shows some susceptibility in caustic environments, and Alloy 800 shows susceptibility in both caustic and highly acidic environments. (authors). 6 figs., 5 refs.

1994-12-31

210

Corrosion mode diagrams for alloy 690 TT and alloy 800  

International Nuclear Information System (INIS)

Due to the well-establish corrosion problems of Alloy 600 as a steam-generator material and the subsequent focus on thermally treated (TT) Alloy 690 and Alloy 800 as alternative materials, a systematic analysis of the corrosion behavior of these two latter alloys is warranted. Corrosion test results for Alloys 690 TT and 800 were collected and organized in the form of corrosion mode diagrams. Selected data for mill annealed (MA) Alloy 600 were also included for reference. The corrosion mode diagrams correlate the modes of corrosion degradation observed in tests as functions of the environment pH and electrochemical potential (ECP). The diagrams confirm that Alloys 690TT shows some susceptibility in caustic environments, and Alloy 800 shows susceptibility in both caustic and highly acidic environments. (authors). 6 figs., 5 refs.

211

Assessment of degradation processes in corrosion resistant steels in nuclear power engineering  

International Nuclear Information System (INIS)

The possible corrosion damage is discussed of the CrNi and CrNiMo types steels used as structural materials in WWER type nuclear power plants. It includes point and slot corrosion, corrosion cracking and corrosion fatigue as well as corrosion denting. Also discussed are test procedures that simulate operating conditions and are used for assessing the properties of metallurgical products (sheets and tubes) used in nuclear power engineering. Briefly described is a system for testing the said products in an aqueous medium while keeping the test parameters in a narrow range for a long time. Under the defined temperature, pressure and corrosion medium composition, the test specimens in this system can mechanically be loaded, both statically and dynamically or a temperature gradient can be produced at the tube-tube plate joint. (Z.M.). 1 fig., 1 tab., 10 refs.

1987-12-01

212

Corrosion of support materials  

International Nuclear Information System (INIS)

Results from a heavily fouled 19 tube C-E model boiler test to investigate the potential for egg crate corrosion in aggressively fouled AVT chemistry are reported. Substantial support plate and egg crate corrosion was produced in this test. Carbon steel drilled support plates exhibited extensive denting which resulted in flow hole ligament cracking. Corrosion of the carbon steel egg crate, through-wall at areas of tube contact, resulted in denting of the Alloy 600 heat transfer tubes. Corrosion performance of the 409 stainless steel egg crate was improved compared to the carbon steel egg crate although localized through-wall corrosion was noted. The results from the above test and previously reported tests were compared based on the following simplifying assumptions: maximum dent size and/or corrosion penetrations utilized, average bulk water chloride ...

1985-03-01

213

Corrosion of high-level waste packaging materials in disposal relevant brines  

International Nuclear Information System (INIS)

Previous corrosion studies identified the materials Hastelloy C4, Ti 99.8-Pd, and carbon steels as promising for the manufacture of long-lived high-level waste containers that could act as an engineered barrier in a rock-salt repository. Here, the efficiency of the corrosion-resistant concept using surface-welded Hastelloy C4 as corrosion protection of carbon steel containers is compared with the corrosion-allowance concept using unalloyed or low-alloyed steels. The materials are examined in three disposal relevant brines (two rich in MgCl_2, one rich in NaCl) at 150 C. The results indicate that welded Hastelloy C4 is highly resistant to corrosion in the NaCl-rich brine. In the presence of sulfides or MgCl_2-rich brines, however, severe pitting corrosion occurs. The three steels investigated are resistant to pitting corrosion in all brines, ...

214

Corrosion control. 2. ed.  

International Nuclear Information System (INIS)

The purpose of this text is to train engineers and technologists not just to understand corrosion but to control it. Materials selection, coatings, chemical inhibitors, cathodic and anodic protection, and equipment design are covered in separate chapters. High-temperature oxidation is discussed in the final two chapters ne on oxidation theory and one on controlling oxidation by alloying and with coatings. This book treats corrosion and high-temperature oxidation separately. Corrosion is divided into three groups: (1) chemical dissolution including uniform attack, (2) electrochemical corrosion from either metallurgical or environmental cells, and (3) stress-assisted corrosion. Corrosion is logically grouped according to mechanisms rather than arbitrarily separated into different types of corrosion as if they were unrelated. For those ...

215

Corrosion control. 2. ed  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this text is to train engineers and technologists not just to understand corrosion but to control it. Materials selection, coatings, chemical inhibitors, cathodic and anodic protection, and equipment design are covered in separate chapters. High-temperature oxidation is discussed in the final two chapters ne on oxidation theory and one on controlling oxidation by alloying and with coatings. This book treats corrosion and high-temperature oxidation separately. Corrosion is divided into three groups: (1) chemical dissolution including uniform attack, (2) electrochemical corrosion from either metallurgical or environmental cells, and (3) stress-assisted corrosion. Corrosion is logically grouped according to mechanisms rather than arbitrarily separated into different types of corrosion as if they were unrelated. For those ...

2001-07-01

216

Status and progress in sludge washing: A pivotal pretreatment method  

Energy Technology Data Exchange (ETDEWEB)

Separation of the bulk soluble chemical salts from the insoluble metal hydroxides and radionuclides is central to the strategy of disposing Hanford tank waste. Sludge washing and caustic leaching have been selected as the primary methods for processing the 230 million L (61,000,000 gal) of Hanford tank waste. These processes are very similar to those selected for processing waste at the West Valley Site in New York and the Savannah River Site in South Carolina. The purpose of sludge washing is to dissolve and remove the soluble salts in the waste. Leaching of the insoluble solids with caustic will be used to dissolve aluminum hydroxide and chromium hydroxide, and convert insoluble bismuth phosphate to soluble phosphate. The waste will be separated into a high-level solids fraction and a liquid fraction that can be disposed of as low-level waste after cesium removal. The washing and leaching operations involve batchwise mixing, settling, and ...

1995-01-01

217

Control rod devices  

International Nuclear Information System (INIS)

Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).

218

The effect of flow velocity on pitting corrosion and stress corrosion cracking of reactor materials  

International Nuclear Information System (INIS)

This paper describes two research programs which are currently underway in the author's laboratory to investigate the effect of fluid flow on the degradation of power plant materials in high temperature/high pressure aqueous environments. These programs include the design and operation of a controlled hydrodynamic corrosion testing apparatus that can be used to study the general and localized corrosion characteristics of alloys in simulated nuclear reactor environments, and a study of the effect of flow velocity on the stress corrosion cracking of ASTM A508 C1.2 steel and Type 304SS in simulated BWR heat transport fluids.

219

Pitting corrosion of steel pipeline in oil-water-gas multiphase flow system  

Energy Technology Data Exchange (ETDEWEB)

Severe pitting corrosion occurred in a horizontal steel pipeline used to transport multiphase fluid, including water, oil, and natural gas, after 2 months of service. The pitting corrosion rate was up to 42 mm/year. Chemical analysis, X-ray diffractometry, and EDAX showed that the corrosion products mainly consisted of Fe9S8, FeCO3, and NaCl. Calcium containing inclusions were also found in the matrix of the steel, which may accelerate corrosion. The early failure was attributed to the high proportion of water, the slow flow velocity, and the use of unqualified material. (Author)

2000-07-01

220

Pitting corrosion of copper and copper alloys. (Latest citations from the Metals Abstracts alloys index database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning the pitting corrosion of copper and copper alloys, in different media, with some references to methods for protecting against such corrosion. Included are factors contributing to the onset of pitting corrosion. Emphasis is placed on exposure to water, especially in tubing for heat exchangers and water conduits. Many of the citations present studies on exposure to sea water. Some references pertain to the detection of pitting corrosion in installations and the evaluation of the degree of pitting present. (Contains 250 citations and includes a subject term index and title list.)

1993-09-01

221

Effect of secondary circuit materials and water regime on steam generator reliability  

International Nuclear Information System (INIS)

The mechanism of the salt concentration increase in pits and crevices formed in a steam generator due to its imperfect manufacture or to its design features is described. The probability of corrosion can be reduced by choosing a suitable steel and by securing low concentrations of salts (chlorides in particular) and corrosion products in the feedwater. Attention is paid to the distribution of salts in the water-steam circuit and to the conditions of erosion corrosion as the principal source of corrosion products in feedwater. Experience with the suppression of erosion corrosion at nuclear power plants abroad is described. (E.J.).

1989-05-01

222

Effect of chloride concentration and pH on pitting corrosion of waste package container materials  

Energy Technology Data Exchange (ETDEWEB)

Electrochemical cyclic potentiodynamic polarization experiments were performed on several candidate waste package container materials to evaluate their susceptibility to pitting corrosion at 90 degrees C in aqueous environments relevant to the potential underground high-level nuclear waste repository. Results indicate that of all the materials tested, Alloy C-22 and Ti Grade-12 exhibited the maximum corrosion resistance, showing no pitting or observable corrosion in any environment tested. Efforts were also made to study the effect of chloride ion concentration and pH on the measured corrosion potential (Ecorr), critical pitting and protection potential values.

1996-12-01

223

Corrosion resistance of oxide scale formed on SiSiC in boiling sulfuric acid  

International Nuclear Information System (INIS)

SiSiC is one of selected materials for the thermal chemical hydrogen production IS (Iodine-Sulfur) process at JAERI. SiSiC was tested in boiling sulfuric acid for 1000 hours. The obtained results showed the following facts. The transverse strength was not changed by sulfuric corrosion, high temperature oxidation and oxidation. Silica scale formed on SiSiC by sulfate corrosion and high temperature oxidation had corrosion resistance in boiling sulfuric acid. Bilayer structure of silica scale produced by high temperature oxidation was not affected by sulfate corrosion. (S.Y.).

224

Phipps Bend Nuclear Plant construction effects monitoring report, October 19, 1978-October 18, 1979  

International Nuclear Information System (INIS)

The aquatic monitoring program consists of onsite monitoring of surface runoff, monitoring of point source discharges identified in the NPDES permit, and limited instream biological monitoring. The program is tied to a feedback mechanism for implementing corrective action before significant adverse impacts occur in the Holston River. This report evaluates the aquatic monitoring program for the second year (October 19, 1978 through October 18, 1979) of construction as required by the NPDES permit, Part III, Section I. Included in this report are data from peripheral runoff monitoring, selected heavy rainfall sampling, ground water monitoring, instream aquatic macroinvertebrate monitoring, and aquatic macrophyte monitoring.

225

Thermal analysis of spent fuel in rehearsal and emergency storage facility (RESF) under station blackout (SBO) in TAPS - 4  

International Nuclear Information System (INIS)

The RESF is utilized for storage of spent fuel under emergency conditions as well as for testing of FM heads. It receives cooling supply from the PHT Pressurizing pumps and after removal of decay heat from the spent fuel it goes to the D2O Storage Tank. The geometry of the RESF system is such that it can not sustain the thermosyphon loop during SBO, due to high frictional forces. To achieve the sustained thermosyphon, modifications in the design were suggested viz., removal of the steam trap and the relief valve above it and replacement by a solenoid valve (SV-16). In the event of SBO, SV-16 will open on 'RESF channel temperature high' signal and connect to FT D2O tank. The tank, being at atmospheric pressure and at lower elevation, will provide higher cooling flow rate through the RESF channel. D2O is periodically removed from the FT D2O tank by operating a Class-II pump intermittently. The analysis ...

2006-11-13

226

The electric fuel zinc-air battery option  

Energy Technology Data Exchange (ETDEWEB)

With specific energy of more than 200 Wh/kg, the Electric Fuel zinc-air battery delivers as much as eight times the energy of lead-acid traction battery, more than twice the energy of the nearest advanced-battery competitor, and as much energy as a tank of gasoline. (author)

1995-12-31

227

Occurrence of fecal indicator bacteria in surface waters and the subsurface aquifer in Key Largo, Florida.  

UK PubMed Central (United Kingdom)

Sewage waste disposal facilities in the Florida Keys include septic tanks and individual package plants in place of municipal collection facilities in most locations. In Key Largo, both facilities discharge...Full Text Available

1995-06-01

228

Measurement of mud level interfaces: A tool for optimization of red mud washing at C.V.G. Bauxilum  

Energy Technology Data Exchange (ETDEWEB)

For the expansion to 2.0 MTPY of the CVG Bauxilum alumina plant, the area of clarification and red mud washing was rearranged from four 2-thickener-5-washer trains to two 1-thickener-7-washer trains. As a result of this modification, the specific mud handling capacity of the existing tanks should be increased by almost 3-times. The time allowed for control actions was then significantly reduced, leading to the need of an on-line level detection system, in order to achieve a better and faster control of the operation. With this scope, it was developed and installed a new continuous mud level detector that gives the measurement of both mud and turbid zone levels in the tanks. The development of the new instrument started with an existing instrument for density measurements which was completely re-engineered in order to obtain the maximum readability in the densities founded along the full range of the tank height. Actually 28 ...

1996-10-01

229

Malaria knowledge and agricultural practices that promote mosquito breeding in two rural farming communities in Oyo State, Nigeria  

UK PubMed Central (United Kingdom)

BackgroundAgricultural practices such as the use of irrigation during rice cultivation, the use of ponds for fish farming and the storage of water in tanks for livestock provide...Full Text Available

230

Investigation of Residue and Coating Stoichiometry on 120-mm Combustible Cartridge Cases.  

Science.gov (United States)

An investigation was conducted to determine the cause of coating residue found in the test gun chambers during qualification firing of 120-mm combustible cartridge case (CCC) ammunition for the MlAl/A2 main battle tank. The CCC is coated with a clear epox...

2000-01-01

231

Foundation of offshore structures  

Energy Technology Data Exchange (ETDEWEB)

This bibliography deals with the foundation of offshore structures like drilling or working platforms (oil and gas exploitation) or offshore tanks. Different kinds of foundations, e.g. pile foundations or shallow foundations, are described. Aspects of soil-structure interaction, engineering geology and soil mechanics are also discussed. (orig.).

1989-08-01

232

Enhanced sludge washing evaluation plan  

Energy Technology Data Exchange (ETDEWEB)

The Tank Waste Remediation System (TWRS) Program mission is to store, treat, and immobilize highly radioactive Hanford Site waste (current and future tank waste and the strontium/cesium capsules) in an environmentally sound, safe, and cost-effective manner. The scope of the TWRS Waste Pretreatment Program is to treat tank waste and separate that waste into HLW and LLW fractions and provide additional treatment as required to feed LLW and HLW immobilization facilities. Enhanced sludge washing was chosen as the baseline process for separating Hanford tank waste sludge. Section 1.0 briefly discusses the purpose of the evaluation plan and provides the background that led to the choice of enhanced sludge washing as the baseline process. Section 2.0 provides a brief summary of the evaluation plan details. Section 3.0 discusses, in some detail, the technical work planned to support the evaluation of enhanced ...

1994-09-01

233

Control of the reduction/oxidation potential of Hanford Waste Vitrification Plant feeds  

International Nuclear Information System (INIS)

A schematic diagram shows the various processing steps to be performed during feed preparation in the Hanford Waste Vitrification Plant (HWVP). The pretreated NCAW is transferred to the slurry receipt adjustment tank (SRAT) in the HWVP for concentration. Water removed during boildown is collected in the slurry mix evaporator condensate tank (SMECT). After waste treatment the water is returned to the storage tanks for eventual disposal. The pretreated Neutralized Current Acid Waste (NCAW) is concentrated in the SRAT to approximately 125 g waste oxides/ liter. Formic acid is then added at a controlled rate to improve rheological properties and achieve a required reduction/oxidation state. Reflux boiling is initiated and continued for several hours. The concentrated slurry is cooled and pumped to the slurry mix evaporator (SME). In the SME, glass frit is added, and the slurry is further concentrated to achieve a nominal ...

1988-09-11

234

BALDWIN COUNTY SEPTIC TANK MAINTENANCE DEMONSTRATION PROJECT MX974480  

Science.gov (United States)

Baldwin County is located on the Gulf of Mexico in Alabama and has a rapidly growing population. Almost 3,000 permits for septic systems are approved annually by by the Baldwin County Health Department. More than 50% of the county's residents rely on septic systems for their d...

235

40 CFR 63.322 - Standards.  

Science.gov (United States)

...Filter gaskets and seatings; (4) Pumps; (5) Solvent tanks and containers; (6) Water separators; (7) Muck cookers; (8) Stills; (9) Exhaust dampers; (10) Diverter valves; and (11) All Filter housings. (l)...

2009-07-01

236

40 CFR 63.321 - Definitions.  

Science.gov (United States)

...limited to, emission control devices, pumps, filters, muck cookers, stills, solvent tanks, solvent containers, water separators...facility that meets the conditions of § 63.320(g). Muck cooker means a device for heating perchloroethylene-laden...

2009-07-01

237

Handling of sodium for the FFTF  

Science.gov (United States)

Based on the High Temperature Sodium Facility (HTSF) experience and the extensive design efforts for FFTF, procedures are in place for the unloading of the tank cars and for the fill of the FFTF reactor. Special precautions have been taken to provide safe handling and to accommodate contingencies in operation. These contingencies include special protective suits allowing personnel to enter and correct conditions arising from fill operations in the course of moving 7.71 x 10/sup 5/ kg (1.7 x 10/sup 6/ lbs) of sodium from the tank cars into the reactor vessel and its loop system.

1978-06-01

238

Freeze protection valve and system  

Energy Technology Data Exchange (ETDEWEB)

The present invention is a device for a solar heating system having a solar collector, a storage tank connected to the solar collector, a pump for circulating liquid from the tank to the solar collector, a supply of liquid at a temperature above freezing and a connection from the supply of liquid to the solar collector for replacing any liquid lost from said solar collector. The device comprises a sensor for sensing the temperature of liquid in the solar collector, and a valve for bleeding liquid from the solar collector when the sensed temperature falls below a predetermined minimum whereby cool liquid in the solar collector is automatically replaced by liquid at a temperature above freezing.

1985-12-10

239

Effect of tetracycline hydrochloride treatment on the critical thermal maximum of common shiners  

Energy Technology Data Exchange (ETDEWEB)

The transfer of fish from field to laboratory facilities or their propagation in closed or restricted systems frequently results in bacterial infection and ultimately large-scale mortality. In attemps to alleviate this problem, we have added tetracycline hydrochloride to the water prophylactically (pretreating tanks before wild fish were added) and therapeutically (treating tanks after bacterial outbreaks were detected.) In the present study, we examined the effect of tetracyline hydrochloride on the critical thermal maximum (CTM) of the common shiner (Notropis cornutus).

1980-01-01

240

The Proposed Yucca Mountain Repository From A Corrosion Perspective  

Energy Technology Data Exchange (ETDEWEB)

Corrosion is a primary determinant of waste package performance at the proposed Yucca Mountain Repository and will control the delay time for radionuclide transport from the waste package. Corrosion is the most probable and most likely degradation process that will determine when packages will be penetrated and the shape, size, and distribution of those penetrations. The general issues in corrosion science, materials science and electrochemistry are well defined, and the knowledge base is substantial for understanding corrosion processes. In this paper, the Yucca Mountain Repository is viewed from a corrosion perspective. A major component of the long-term strategy for safe disposal of nuclear waste at the Yucca Mountain Repository is first to completely isolate the radionuclides in the waste packages for long times and to greatly retard the egress and transport of radionuclides ...

2005-04-12

241

Prediction of Corrosion of Advanced Materials and Fabricated Components  

Energy Technology Data Exchange (ETDEWEB)

The goal of this project is to provide materials engineers, chemical engineers and plant operators with a software tool that will enable them to predict localized corrosion of process equipment including fabricated components as well as base alloys. For design and revamp purposes, the software predicts the occurrence of localized corrosion as a function of environment chemistry and assists the user in selecting the optimum alloy for a given environment. For the operation of existing plants, the software enables the users to predict the remaining life of equipment and help in scheduling maintenance activities. This project combined fundamental understanding of mechanisms of corrosion with focused experimental results to predict the corrosion of advanced, base or fabricated, alloys in real-world environments encountered in the chemical industry. At the heart of this approach is the development of models ...

2007-09-29

242

Critical pitting potential of aluminium alloys. Aluminum gokin no koshoku den prime i  

Energy Technology Data Exchange (ETDEWEB)

Pitting corrosion measuring method for almunum alloys sold on the market was studied. By addition of a little quantity of Cu {sup ++} ion, corrosion potential of alminum alloys rapidly approachs to pitting corrosion potential in the solution including chloride. After Cu {sup ++} ion of 5ppm is added in advance into the solution including chrolide to measure the pitting corrosion potential, alminum alloy test pieces are imersed into the solution in the atmospheric air, then the stable corrosion potential is shown after three-minite imersion, and this potential is defined to the pitting corrosion potential. The pitting corrosion potential can be easily measured by this method stated above (copper ion method). The values measured by copper ion method is comparatively agreed with that measured by the existing potentio dynamic method. The pitting ...

1990-02-15

243

Corrosion of container materials for disposal of high-level radioactive wastes  

Energy Technology Data Exchange (ETDEWEB)

In the corrosion aspect of container for the deep geological disposal of high-level radioactive waste, disposal concepts and the related container materials, which have been developed by advanced countries, have been reviewed. The disposal circumstances could be divided into the saturated and the unsaturated zones. The candidate materials in the countries, which consider the disposal in the unsaturated zone, are the corrosion resistant materials such as supper alloys and stainless steels, but those in the saturated zone is cupper, one of the corrosion allowable materials. By the results of the pitting corrosion test of sensitized stainless steels (such as 304, 304L, 316 and 316L), pitting potential is decreased with the degree of sensitization and the pitting corrosion resistance of 316L is higher than others. And so, the long-term corrosion experiment with 316L ...

1999-01-01

244

Applications of cathodic protection for the protection of aqueous and soil corrosion of power plant components  

International Nuclear Information System (INIS)

Power plant components exposed to environments such as water and soil are susceptible to severe corrosion. Many times the effect of corrosion in power plant components can be catastrophic. The problem is aggravated for underground pipelines due to additional factors such as large network of pipelines, proximity to earth mat, high voltage transmission lines, corrosive chemicals, inadequate approach etc. Other components such as condenser water boxes, internals of pipelines, clarifier bridge structures, cooling water inlet gates and pipes etc. which are in continuous contact with water, are subjected to severe corrosion. The nature and locations of all such components are at places which are not accessible for routine maintenance and hence they require long term reliable protection against corrosion. Experience has shown that anti-corrosive coatings are inadequate ...

1999-11-22

245

Investigations into the corrosion resistance of copper aluminium alloys. Effect of phosphorus as corrosion resistant third alloying element in the ternary system CuAl20P1  

International Nuclear Information System (INIS)

The effect of phosphorus on the corrosion resistance of Al-bronzes is studied in detail in this work. A literature review showed that there are a lot of things known about the microstructure and the mechanical properties of Al-bronzes. In spite of their corrosion resistance the corrosion properties and the structure of the protective oxide films of Al-bronzes were seldom a matter of interest. Systematic studies of the influence of different alloying elements on the oxide film and the corrosion properties are rare. Therefore, it is not possible to predict the corrosion resistance of Al-bronzes, made by alloying particular elements. The high corrosion resistance of the new alloy CuAl_2_0P_1 was the reason to investigate the influence of phosphorus on the corrosion properties of Al-bronzes in more detail. A systematic study of the ...

246

Effect of chlorides on the corrosion behaviour of mild steel  

International Nuclear Information System (INIS)

In PWR's steam generators, ''denting'' resulted from corrosion of support plate material, carbon steel is an important problem. The role of chlorides in corrosion acceleration of mild steel was studied. Corrosion tests were conducted at temperature from 100"0C to 280"0C in deaerated solutions of NaCl and MgCl_2 which are main content of sea water. 1) Solution of MgCl_2 was more corrosive than that of NaCl. The more increased in concentration of each chloride solution, the more corrosive in MgCl_2 soln. but the less corrosive in NaCl soln. 2) The rate of corrosion in the mixed solution of NaCl and MgCl_2 was governed by the concentration of MgCl_2 soln. The corrosion behaviour in sea water was suggested to be not controlled by NaCl but by MgCl_2. 3) Acidification of MgCl_2 soln. could be evaluated by experiment at 100"0C, ...

247

Low-activity waste envelope definitions for the TWRS Privatization Phase I Request For Proposal  

Energy Technology Data Exchange (ETDEWEB)

Radioactive waste has been stored in large underground storage tanks at the Hanford Site since 1944. Approximately 212 million liters of waste containing approximately 240,000 metric tons of processed chemicals and 177 mega-curies of radionuclides are now stored in 177 tanks. These caustic wastes are in the form of liquids, slurries, saltcakes, and sludge. In 1991, the Tank Waste Remediation System (TWRS) Program was established to manage, retrieve, treat, immobilize, and dispose of these wastes in a safe, environmentally sound, and cost-effective manner. The Department of Energy (DOE) has believes that it is feasible to privatize portions of the TWRS Program. Under the privatization strategy embodied in the Request for Proposal (RFP), DOE will purchase services from a contractor-owned, contractor-operated facility under a fixed-price contract. Phase I of the TWRS privatization strategy is a proof-of-concept/commercial ...

1996-11-01

248

Implementation plan for liquid low-level radioactive waste tank systems for fiscal year 1995 at Oak Ridge National Laboratory under the Federal Facility Agreement, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

This document is the third annual revision of the plans and schedules for implementing the Federal Facility Agreement (FFA) compliance program, originally submitted in 1992 as ES/ER-17&D1, Federal Facility Agreement Plans and Schedules for Liquid Low-Level Radioactive Waste Tank Systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee. This document summarizes the progress that has been made to date in implementing the plans and schedules for meeting the FFA commitments for the Liquid Low-Level Waste (LLLW) System at Oak Ridge National Laboratory (ORNL). Information presented in this document provides a comprehensive summary to facilitate understanding of the FFA compliance program for LLLW tank systems and to present plans and schedules associated with remediation, through the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) process, of LLLW tank systems that have been removed from ...

1995-06-01

249

Design and construction of 125,000kl industrial water tank foundations for Tachibanawan power plant. Deformation in large pile foundations on inclined rockbed and evaluation thereof; Tachibanawan hatsudensho 125,000 kl kogyoyosui tank kiso no sekkei to seko. Keisha kiso ganbanjo no ogata kui kiso no henkei tokusei to hyoka  

Energy Technology Data Exchange (ETDEWEB)

The two tank (125,000kl each) foundations under construction are as large as 85m in diameter, and the north-side tank is to be placed over a sharper slope. The tanks are greatly different in their height from the rockbed since they are to be placed at the same level. For reduction in construction cost and time, a pile foundation design is chosen as the basic concept for foundation construction. After an overall evaluation of stability upon exposure to seismic torsion and of the deformation characteristics of piles and concrete slabs, a total pile foundation design with rock debris replaced with crushed rock is determined to be the design to be adopted. Since the piles to be driven in are greatly different in length, error in the pile supporting force will be too grave under the conventional pile landing control system. Therefore, a high-accuracy pile landing control system is employed, established after a rapid load test in ...

1998-09-05

250

TEM and ToF-SIMS studies on the corrosion behavior of vanadium and chromium containing WC-Co hard metals in alkaline solutions  

British Library Electronic Table of Contents (United Kingdom)

The corrosion behavior of hard metals with VC and Cr3C2 grain growth inhibitors was investigated in alkaline solutions by electrochemical methods. The two inhibitors have opposite effects on the corrosion behavior: Cr3C2 significantly improves the corrosion behavior, whereas VC-containing alloys show a poor resistance. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) and analytical transmission electron microscopy (TEM) analyses of the distributions of Cr and V in the composite material, as well as in the surface layers formed during corrosion were employed to clarify the influence of these elements on the corrosion behavior. The measurements showed that VC is precipitated mostly along the WC/binder interface after the liquid-phase sintering process, while Cr3C2 is almost homogene...

2011-01-01

251

ISO - ISO Standards - TC 156 - Corrosion of metals and alloys  

Wastenet

...ISO - ISO Standards - TC 156 - Corrosion of metals and alloys go to main navigation go to content area go to search International Standards for Business,...ISO Members FAQs Fr ISO Store Products ISO Standards By TC TC 156 Corrosion of metals and alloys ISO Store ISO Standards By ICS By ...aerospace standards Publications and e-products ISO Concept Database (ISO/CDB) Copyright TC 156 - Corrosion of metals and alloys Items to be displayed: Published ...responsibility of TC 156 Secretariat Standard and/or project Stage ICS 3ISO/WD 7441 Corrosion of metals and alloys Determination of bimetallic corrosion in outdoor ...

252

Effect of tungsten on the corrosion behavior of sulfuric acid-resistant steels for flue gas desulfurization system  

British Library Electronic Table of Contents (United Kingdom)

Flue gas desulfurization systems (FGDs) are operated in severely corrosive environments that cause sulfuric acid dew-point corrosion. The corrosion behavior of low-alloy steels was tested using electrochemical techniques (electrochemical impedance spectroscopy, potentiodynamic tests, potentiostatic tests), and the corrosion products were analyzed by scanning electron microscopy and X-ray photoelectron spectroscopy. The electrochemical results showed that alloying W with small amounts of Sb, Cu, and Co improves the corrosion resistance of steels. The results of surface analyses showed that the surface of the steels alloyed with W consisted of W oxides and higher amounts of Sb and Cu oxides. This suggests that the addition of W promotes the formation of a protective WO3 film, in addition to ...

2011-01-01

253

Corrosion resistance of materials of construction for high temperature sulfuric acid service in thermochemical IS process. Alloy 800, Alloy 600, SUSXM15J1 and SiC  

International Nuclear Information System (INIS)

Exposure tests of candidate materials were carried out up to 1000 hr in the sulfuric acid environments of thermochemical hydrogen production IS process, focusing on the corrosion of welded portion and of crevice area. In the gas phase sulfuric acid decomposition condition at 850degC, welded samples of Alloy 800 and of Alloy 600 showed the same good corrosion resistance as the base materials. In the boiling condition of 95 wt% sulfuric acid solution, test sample of SiC showed the same good corrosion resistance. Also negligible corrosion was observed in crevice corrosion. (author)

2006-07-01

254

Corrosion resistance in magnesium alloys and deposition coated magnesium alloy  

Energy Technology Data Exchange (ETDEWEB)

Corrosion behavior of deposition coated specimens prepared by the technique proposed by the authors is investigated in salt immersion tests, and also those of pure magnesium, 3N, 4N and 6N grades, and magnesium alloys, AZ31 and AZ91E, are investigated for comparison. Inhomogeneous corrosion occurs in AZ31 and AZ91E alloys when buffered solutions with pH values of 6.5 and 9.0 including 1% NaCl and a conventional 3% NaCl solution are used for immersion tests, while 6N-Mg shows homogeneous corrosion in such solutions. Corrosion behavior of the deposition coated specimen resembles that of 6N-Mg. Purification process included in the deposition coating technique provides homogeneity in microstructural and electrochemical terms, which results in improving corrosion resistance. (orig.)

2003-07-01

255

Corrosion behavior of sputter-deposited W-Nb alloys in NaCl and NaOH solutions  

International Nuclear Information System (INIS)

The corrosion behavior of the sputter-deposited amorphous or nanocrystalline W-Nb alloys is studied in 10% NaCl, 0.1 and 1 M NaOH solutions at 24 deg. C, open to air using immersion tests and electrochemical measurements. Niobium metal acts synergistically with tungsten in enhancing the corrosion resistance of the W-Nb alloys so as to show lower corrosion rates than the corrosion rates of the alloy-constituting elements in almost all examined solutions. Corrosion rates of W-Nb alloys are about more than one order of magnitude less than that of the sputter-deposited tungsten and even lower than that of sputter-deposited niobium. The stability of the anodic passive films formed on the W-Nb alloys increase with niobium content.

2008-05-29

256

Analysis of deteriorating processes in primary circuit facilities and determination of their priorities and relevance to the lifetime of the main primary circuit components  

International Nuclear Information System (INIS)

The major degradation mechanisms acting during the aging of selected WWER-440/213 primary circuit facilities were assessed critically. The analysis gave evidence that such mechanisms include radiation and fatigue damage of the reactor pressure vessel (effect of the neutron flow, cyclic fatigue promoted by the corrosive medium, effect of thermal aging), corrosion-mechanical and thermo-mechanical (fatigue) damage of the steam generator (stress corrosion cracking, erosion corrosion, thermal aging, wear), thermal and dynamic aging of the pressurizer, and corrosion-mechanical damage of the primary circuit piping (thermal aging, corrosion). (J.B.). 5 tabs., 1 fig., 62 refs.

257

Weakly penetrating radiation monitoring and assessment at Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

Weakly penetrating radiation monitoring and investigating with area monitors and individual dosimeters were carried out at Daya Bay nuclear power plant during its refueling outages. This paper introduces monitoring methods, measuring results, data analysis and assessment, presents some suggestions for monitoring plan and protection measures in the future as well. (authors)

2006-05-01

258

Modernizing steam turbines for nuclear power plants  

International Nuclear Information System (INIS)

Economic and safe operation of nuclear power plants requires reliable steam turbines with high efficiencies. The progress in flow mechanics achieved over the past few years has allowed the use of powerful methods of flow calculation in developments of new blading with greatly enhanced efficiencies. Thanks to the latest manufacturing techniques, the newly developed blading systems can be produced at low cost. Next to progress in flow mechanics, also the broadbased use of advanced finite-element calculations resulted in a more thorough grasp of the many problems associated with structural mechanics assessment of steam turbine components. The theoretical methods have been supplemented by comprehensive efforts in fracture mechanics and experimental materials studies, thus helping to create a reliable knowledge base which will help to avoid the dreaded stress corrosion cracking phenomenon, in components of steam turbines. The measures introduced to improve operational ...

259

Failed nuclear fuel rod analysis by gamma computed tomography  

International Nuclear Information System (INIS)

Fuel rod failures produce a release of fission products into primary coolant system. Since nuclear power plants have licensing limits for the release of volatile fission products to the environment (off-gas limits) detailed monitoring of the development of clad failure is necessary. In case of fuel rod failure a release of fission products into the primary coolant system arises. Fission gases accumulated in the free volume of a fuel rod escape through the clad defect. Water entering the fuel rod reacts with fission products, forming volatile chemical compounds. These may escape in a similar manner into the fission gases. Other compounds may dissolve and may be carried outside the fuel rod as dissolved species. Consequently, the distribution of these fission products, in the cross section of the fuel rod, is modified. An implementation of the maximum entropy gamma computed tomography technique is used to obtain such distributions in the area of the fuel rod ...

260

Remote environmental monitoring at No. 26 Colliery  

Energy Technology Data Exchange (ETDEWEB)

The author describes the layout of the environmental monitoring scheme at Devco's No. 26 Colliery in Canada, which includes wall face ventilation, fan performance, and methane drainage monitoring. He gives details of the sensors, outstations, and the surface control room.

1982-03-01

261

Remote control monitoring - a review of the latest equipment  

Energy Technology Data Exchange (ETDEWEB)

This article reviews briefly a range of the latest monitoring and controlling equipment for use in coal mines. This includes pressure transmitters, shale/coal discriminator, nucleonic bunker level indicator, automatic steering and monitoring system, oscilloscope/multimeter, and microprocessor based digital display controllers. 1 fig.

1988-01-01

262

Monitoring the atmosphere in underground mines  

Energy Technology Data Exchange (ETDEWEB)

This article consists of a series of manufacturer's descriptions outlining specifications of underground monitoring equipment which range in complexity from gas sensitive personal badges to full mine monitoring systems. 8 figs.

1988-12-01

263

Computerised, remote monitoring systems for underground coal mines  

Energy Technology Data Exchange (ETDEWEB)

This report presents a study on the use of computerised, continuous remote monitoring systems for fire and explosive atmosphere safety in underground coal mines. The effects of these systems on the safety level in mines are investigated, and the relationship between mine safety regulations and computerised, continuous, remote monitoring is analysed.

1983-03-01

264

Complete programming documentation for ECIP expansion of existing Energy Monitoring and Control System (EMCS), Fort Leonard Wood, Missouri  

Science.gov (United States)

The objective of this project is to reduce energy consumption in 203 buildings by providing a new EMCS (Energy Monitoring Control System) to control and monitor systems.

1993-12-01

265

Aquatic Resource Monitoring  

Wastenet

...research strategy and plans Aquatic resource monitoring research programs, EMAP and STAR grants Go To EMAP homepage Go To Top Bibliography References for survey designs, statistical analyses , program documentation, and monitoring reports. Reports, abstracts and links to electronic versions Go To Top Frequently Asked Questions ...

266

LITERATURE SURVEY OF THE CORROSION BEHAVIOR OF TANTALUM, ZIRCONIUM, AND TITANIUM  

Science.gov (United States)

The corrosion behavior of Ta, Ti, and Zr in inorganic acids, bases, chlorides and miscellaneous salts, waters and gases, and organic acids and miscellaneous organic chemicals is summarized. (W.L.H)

1955-02-23

267

Field corrosion tests for a low chromium steel carried out at superheater area of a utility boiler with three coals containing different chlorine contents  

Energy Technology Data Exchange (ETDEWEB)

Field corrosion tests for a low chromium steel were carried out at a superheater area of a 100 MW pulverized coal-fired boiler for various times up to 500 h, when three coals having different chlorine contents were combusted. The low chromium steel had obvious metal loss due to corrosion, and comparison of the metal loss and corrosion scale structure was made among the three coals in respect to chlorine contents as well as other elements affecting its corrosion. Corrosion scales of the low chromium steel had a general two-layer structure: an inner layer containing iron, chromium, oxygen and sulfur, and an outer layer made of porous iron oxide and fly ash particles. Distinct molten phase formation, which is an indication of severe corrosion, was observed for the coal containing only the middle high chlorine, and it initiated in the outer layer of the ...

2007-04-15

268

Effects of oxygen, copper and acid chlorides on denting corrosion  

Energy Technology Data Exchange (ETDEWEB)

The effect of dissolved oxygen and copper on denting corrosion at 280/sup 0/C in solutions of NaCl at pH 9 with ammonia was investigated using a packed tube/support plate crevice in a laboratory simulation. The onset of corrosion was detected with a hydrogen analyzer sensitive to 0.2 ppB. In the absence of copper, rapidly rising hydrogen concentrations were detected only when the product of the chloride and oxygen concentrations were detected only when the product of the chloride and oxygen concentrations in the boiler-water exceeded 25 (ppM)/sup 2/, but at these high concentrations, unheated low-carbon steel surfaces in the system were as sensitive to corrosion as the heated crevice. When copper metal was present in the feed system, corrosion of the heated crevice occurred in the absence of oxygen, provided the copper had previously been exposed to dissolved oxygen. Dosing hydrazine into the feedwater ...

1986-07-01

269

Effect of mineral compounds in phosphoric acid polluted by sulfide ions on corrosion of nickel  

Energy Technology Data Exchange (ETDEWEB)

The inhibiting effects of two mineral compounds on corrosion of nickel in phosphoric acid (H[sub 3]PO[sub 4]) polluted by sulfide ions (S[sup 2[minus

1999-06-01

270

Effect of dissolved oxygen on denting corrosion  

International Nuclear Information System (INIS)

The following conclusions are drawn from the study of the effects of dissolved oxygen on corrosion denting: 1) Following the ingress of fresh-water contamination into a PWR boiler, an acidic chloride solution can be formed in the crevice between tube and tube support plate when an oxidant such as dissolved oxygen or copper ions is present in the boiler water. 2) In the absence of copper, very high levels of dissolved oxygen and neutral chloride are necessary to initiate corrosion. 3) When copper is present in the feed system, sufficient copper ions to initiate corrosion within the crevice are released when the chloride concentration is 0.8 mg/kg and probably also at lower chloride values. Corrosion initiation however may require prior exposure of the copper to dissolved oxygen and can be suppressed by pretreatment with hydrazine. 4) The effect of dissolved oxygen on corrosion ...

1985-03-01

271

Corrosion resistance of austenitic steels and alloys in high temperature water  

International Nuclear Information System (INIS)

An ampoule corrosion tests technique is presented for making a comparative corrosion-proof estimation of austenitic steels and alloys which are candidate materials for the ITER first wall and shield blanket. Influence of Cl"- on the rate and character of corrosion cracking has been determined. The dependence of time before destruction on Cl"- contents was obtained by experiments in twice-distilled water at a Cl"- content value of less than 0.05 mg/l. Kinetics of a corrosion crack growth has been determined by way of acoustic emission and measurement of electrical resistance. It has been revealed, that corrosion cracking of 316L and 316Ti steels in water with 100 mg/l of Cl"- takes place at temperatures over 50 C. For 316L (Russian analogue), 316Ti, 08Cr18Ni10Ti (type 304), 00Cr16Ni15Mo3Nb (type 316) steels and CrNiMo-1 (42-47%Cr, 1%Mo, Ni-base) alloy corrosion ...

272

Comparison of susceptibility to pitting corrosion of AA2024-T4, AA7075-T651 and AA7475-T761 aluminium alloys in neutral chloride solutions using electrochemical noise analysis  

Energy Technology Data Exchange (ETDEWEB)

The susceptibility to pitting corrosion of AA2024-T4, AA7075-T651 and AA7475-T761 aluminium alloys was investigated in aqueous neutral chloride solution for the purpose of comparison using electrochemical noise measurement. The experimentally measured electrochemical noises were analysed based upon the combined stochastic theory and shot-noise theory using the Weibull distribution function. From the occurrence of two linear regions on one Weibull probability plot, it was suggested that there existed two stochastic processes of uniform corrosion and pitting corrosion; pitting corrosion was distinguished from uniform corrosion in terms of the frequency of events in the stochastic analysis. Accordingly, the present analysis method allowed us to investigate pitting corrosion independently. The susceptibility to pitting corrosion was ...

2008-01-15

273

Chromium steel corrosion rates and mechanisms in aqueous nickel chloride at 300C  

International Nuclear Information System (INIS)

Rapid corrosion of PWR steam generator carbon steel support structures and consequential denting of steam generator tubes led to investigation of alternative support designs and materials. In recent designs of steam generators the carbon steel drilled hole tube support plate has been replaced by one of quatrefoil or trefoil shape to minimize the contact area. These plates are now made of more corrosion resistant chromium steel (approx. 12%Cr) to ensure that they are less vulnerable to attack in the event of adverse boiler water chemistry. This study was initiated to examine the corrosion behavior of a range of chromium steels in the acid chloride environments characteristic of tube/support plate crevices under adverse boiler water conditions. Objectives of the study were to: 1) determine the relative susceptibility of candidate tube support plate steels to acid chloride corrosion; 2) investigate the ...

1985-03-01

274

Carbon steel corrosion rates and mechanisms in aqueous nickel chloride at 300C  

International Nuclear Information System (INIS)

Rapid corrosion of PWR steam generator carbon steel support structures and consequential denting of steam generator tubes led to considerable investigation of the mechanism of corrosion and for palliatives. The basic mechanism is now fairly well understood. Chloride present in the boiler feedwater from condenser leakage is concentrated in the support plate crevice as a result of the superheat present. This leads to the formation of a low pH acid ferrous chloride environment either through the hydrolysis of a weak base chloride such as MgCl_2 or the combined action of a neutral chloride with an oxidizing agent. Rapid attack of the carbon steel ensues with the Fe_3O_4 corrosion product forming at the metal/oxide interface. This oxide has a volume approximately twice that of the steel consumed and thus eventually fills the crevice between the tube and the support plate. Oxide growth continues leading to compression of the ...

1985-03-01

275

New developments in the surveillance and diagnostics technology for vibration, structure-borne sound and leakage monitoring systems  

International Nuclear Information System (INIS)

Monitoring and diagnostic systems are of main importance for a safe and efficient operation of nuclear power plants. The author describes new developments with respect to vibration monitoring with a functional extension in the time domain for den secondary circuit, the development of a local system for the surveillance of rotating machines, the structure-borne sound monitoring with improvement of event analysis, esp. the loose part locating, leakage monitoring with a complete system for humidity measurement, and the development of a common platform for all monitoring and diagnostic systems, that allows an efficient access for comparison and cross references.

277

Understanding the operation and use of high temperature electrochemical corrosion rate probes  

Energy Technology Data Exchange (ETDEWEB)

Electrochemical corrosion rate probes were constructed and tested along with mass loss coupons in a N2/O2/CO2 plus water vapor environment. Temperatures ranged from 450 to 600 C. Corrosion rates for ash-covered mild steel, 304L SS, and 316L SS probes using electrochemical techniques were a function of time, temperature, and process environment. Correlation between electrochemical and mass loss corrosion rates was good.

2004-01-01

278

Total corrosion and film analysis of SUS and Ni base alloy in supercritical water  

International Nuclear Information System (INIS)

... Toshiba Corporation, Isogo Engineering Center, Yokohama, Kanagawa (Japan)

2005-09-01

279
280

Summary on performance study of corrosion resistance of zirconium alloys  

International Nuclear Information System (INIS)

Zirconium-base alloys are used primarily as fuel cladding material and other core structure material in water cooled nuclear power reactors. Main research achievements and problems about corrosion of zirconium alloys are reviewed; the present theories and challenge are summarized. In the 1980s, great progress had been made towards correlating alloy composition, microstructure and irradiation with corrosion resistance. In the 1990s, main researches are focused on exploring actual mechanism of corrosion, optimizing both alloy composition and microstructure in order to minimize the fuel cycle costs through burnup optimization.

281

Stress corrosion cracking and pitting corrosion relation for zircaloy-4 in chloride-containing hydro-alcoholic media  

International Nuclear Information System (INIS)

A study of stress corrosion cracking susceptibility of Zircaloy-4 in chloride-containing aqueous methanolic media is presented. The influence of water content is investigated in the 5-100 vol. % water range. The dependence of stress corrosion cracking on potential is evidenced. A close correlation is established with pitting susceptibility determined by a statistical analysis of induction times. A correlation with the repassivation potential is observed in the water-rich solutions. In the low water content solutions, two repassivation curves are determined according to the experimental technique. Pit morphology and fractography show a transition from aqueous to organic media. (author).

282

Steam generator tube performance  

International Nuclear Information System (INIS)

A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization.

2005-10-27

283

Secondary side concept to prevent steam generator tube corrosion  

International Nuclear Information System (INIS)

Some examples are given of design adaptations, e.g. U-bend support, tube spacer grid, flow distribution baffle, triangular tube pitch, tube-tubeplate sheet connection, which reduce the tendency to various types of corrosion (stress corrosion cracking, tube denting, tube wastage, intergranular cracking). A basic diagram of the secondary circuit is shown. Oxygen, corrosion product and impurity control in the secondary circuit is described. (E.J.). 19 figs., 6 refs.

1989-05-01

284

SALT WATER CORROSION TEST OF ROLLING SURFACE ...  

Science.gov (United States)

... by the Bureau. A canvas of supply sources produced only one other, the Flexo roller bearing swivel. Accordingly, only the ...

1955-04-04

285

RESULTS ON INCOLOY 800 AND ALLIED STEAM ...  

Science.gov (United States)

... Title : RESULTS ON INCOLOY 800 AND ALLIED STEAM GENERATOR MATERIALS IN FLORIDA FIELD CORROSION TESTS,. ...

287

Longer life for steam generators  

Science.gov (United States)

Eight years ago, corrosion and tube denting seriously threatened the reliability and design life of steam generators, especially for closed loop arrangements in pressurized water reactors (PWRs). Concentrated research by the Steam Generator Owners Group (SGOG) diagnosed the causes and produced effective solutions, notably guidelines for water chemistry control in the secondary loop. The guidelines recommend specific levels of water impurities and remedial actions to prevent cooling-water leaks in the condenser, prevent air leaks, limit corrosion product buildup, and remove some impurities while neutralizing others. Continued research in SGOB-II is investigating intergranular corrosion and stress corrosion cracking. 3 figures.

1984-10-01

288

Longer life for steam generators  

International Nuclear Information System (INIS)

Eight years ago, corrosion and tube denting seriously threatened the reliability and design life of steam generators, especially for closed loop arrangements in pressurized water reactors (PWRs). Concentrated research by the Steam Generator Owners Group (SGOG) diagnosed the causes and produced effective solutions, notably guidelines for water chemistry control in the secondary loop. The guidelines recommend specific levels of water impurities and remedial actions to prevent cooling-water leaks in the condenser, prevent air leaks, limit corrosion product buildup, and remove some impurities while neutralizing others. Continued research in SGOB-II is investigating intergranular corrosion and stress corrosion cracking. 3 figures.

289
290

Influence of microalloying on the corrosion resistance of steel in saturated calcium hydroxide  

International Nuclear Information System (INIS)

The influence of microalloying vanadium or titanium on improving the corrosion resistance of mild steel in saturated calcium hydroxide solution was investigated. Potential-time, potentiodynamic polarization, and impedance measurement techniques were employed. The corrosion products have been examined by infrared and X-ray diffraction analysis and by scanning electron microscopy. It has been shown that the grain refining, due to microalloying, plays an important role in enhancing the corrosion resistance of steel. Scales of calcite and iron oxides on top of a protective oxide are formed on the investigated steels.

292

Effect of deformation on corrosion behavior of Ti-23Nb-0.7Ta-2Zr-O alloy  

International Nuclear Information System (INIS)

The influence of deformation on the corrosion behavior of a newly developed multifunctional beta titanium alloy Ti-23Nb-0.7Ta-2Zr-O (mol%) in Ringer's solution at 310 K was evaluated using an electron backscatter diffraction technique and electrochemical measurements. The results showed that the effect of deformation on the corrosion resistance of the beta titanium alloy is complicated. Small levels of plastic deformation are detrimental to the corrosion resistance, whereas large deformations tend to eliminate this detrimental effect.

2009-03-01

293

Effect of crystal orientation on the stress corrosion cracking of L-grade stainless steel  

International Nuclear Information System (INIS)

... Yoshiaki Toshiba Corp., Nuclear Power Division, Yokohama, Kanagawa (Japan)

2007-05-01

294

Diffusion Zink Planting of Steels  

International Science & Technology Center (ISTC)

Research on Diffusion Zinc Cladding of Structural Steels, as Well as Their Mechanical and Corrosion Properties to Replace Their Cyanic Cadmium Plating

295

Difference in the effects produced by non-radioactive and radioactive calcium  

International Nuclear Information System (INIS)

... aluminum calcium calcium 45 cations citric acid corrosion inhibition radiation

296

Corrosion properties of carbon steels under PWR secondary water environment  

International Nuclear Information System (INIS)

... Japan) Kobayashi, Minoru AITEL Corp., Yokohama, Kanagawa (Japan)

2009-05-01

297

Corrosion characteristics of grain-refining materials in sub-critical and supercritical water  

International Nuclear Information System (INIS)

... Tohoku University, Graduate School of Engineering, Sendai, Miyagi (Japan)

2006-05-01

298

Corrosion and stress corrosion cracking of alloy 800 in water and steam at elevated temperatures  

International Nuclear Information System (INIS)

The importance that must be attached to the phenomenon of stress corrosion cracking of austenitic alloys is emphasized. The relation between chemical composition of various alloys and their sensitivity to cracking is shown with particular reference to the behaviour of Alloy 800. The different effects of alkaline anc chloride environments are discussed. Studies are reported of the general corrosion of Alloy 800 and other alloys in an environment representative of the primary coolant of PWR reactors; and of the behaviour of various alloys (including Alloy 800) in the conditions envisaged for their use for steam generators with superheat up to about 550 deg.C. (U.K.).

299

Application of the stochastic process to pitting corrosion  

Energy Technology Data Exchange (ETDEWEB)

Pitting corrosion can be considered as a combination of two physical processes: the pit generation process and its depth growth process. Both processes are uncertain and can be modeled by stochastic processes. A model that combines two stochastic processes to describe pitting corrosion was developed. In this model, the pit generation process is represented by the Poisson process, and the pit depth growth process is modeled by the Markov process. The probability distribution of corrosion pit depth and the probability of time-to-failure are derived based upon the combined stochastic processes. Examples of the use of this method in dealing with experimental data also were developed.

1999-01-01

300

Acid corrosion inhibition of copper by mangrove tannin  

British Library Electronic Table of Contents (United Kingdom)

Purpose - The purpose of this paper is to evaluate the corrosion inhibition potential of mangrove (Rhizopora apiculata) tannin in hydrochloric acid medium on copper with the view of developing a natural corrosion inhibitor. Design/methodology/approach - The mangrove tannin was extracted from the mangrove bark and its anticorrosion potential was studied by weight loss, electrochemical and scanning electron microscopy (SEM) analysis. Findings - It has been found that the mangrove tannin effectively inhibits the corrosion on copper metal in hydrochloric acid solution. The results of the electrochemical and weight loss methods showed that the inhibition efficiency of mangrove tannin increases with increasing its concentration. Inhibition is achieved through the adsorption of tannin molecules o...

2011-01-01

301

A review of the probabilistic aspects of localized corrosion  

Energy Technology Data Exchange (ETDEWEB)

Localized corrosion has a stochastic character by nature. This character leads to an observed random behavior: fluctuations of the free potential, fluctuations of the current when a constant potential is maintained. This random signal, which is similar to an electric noise, can be analyzed either in the time domain by counting the events or in the frequency domain by measuring the power spectral density of the electrochemical noise. The experimental techniques developed for investigating the localized corrosion on the probabilistic point of view, i.e., statistical counting and power spectral density measurements, are discussed. Then the experimental results reported in the literature are reviewed in order to see what kind of parameters are accessible and how they can be related to the localized corrosion processes.

1990-04-01

302

Wireless connectivity for health and sports monitoring: a review  

UK PubMed Central (United Kingdom)

This is a review of health and sports monitoring research that uses or could benefit from wireless connectivity. New, enabling wireless connectivity standards are evaluated for their suitability, and...Full Text Available

2007-05-01

303

UARS Particle Environment Monitor (PEM) Level 3AT - Mirador - NASA  

Science.gov (United States)

May 11, 2011 ... The Particle Environment Monitor (PEM) on NASA's Upper Atmosphere Research Satellite (UARS) measures the type, amount, energy, and ...

304

Technical Basis for Radiological Workplace Air Monitoring and Sampling for the River Corridor Project 300 area  

Energy Technology Data Exchange (ETDEWEB)

This report documents the technical basis by which the workplace air monitoring and sampling program is operated in the 324 and 327 Buildings.

2000-01-17

305

Soil Moisture Monitoring for Agriculture  

International Science & Technology Center (ISTC)

Elaboration of a Modern Technology for Operational Agrometeorological Soil Moisture Monitoring Spring Wheat, Yield and Disease Damage Forecasting and Recommendations for Plant Protection on the Kazakhstan Territory

306

Optical Spectroscopy for Noninvasive Monitoring of Stem Cell Differentiation  

UK PubMed Central (United Kingdom)

There is a requirement for a noninvasive technique to monitor stem cell differentiation. Several candidates based on optical spectroscopy are discussed in this review: Fourier transform infrared (FTIR)...Full Text Available

2010-01-01

307

NAME=\\  

Wastenet

...Air Quality Monitoring Networks Products and Equipment Find and compare a variety of air quality monitoring networks products and equipment on the world's largest environmental industry portal. ...

308

Myxoviruses Monitoring in Seals Populations  

International Science & Technology Center (ISTC)

Comparative Molecular Genetic Monitoring of Myxoviruses Circulating in Populations of Seals Phoca Caspia and Phoca Sibirica in Northern Caspian Region and Lake Baikal

309

Adducted proteins for identification of endogenous electrophiles.  

UK PubMed Central (United Kingdom)

Chemically reactive compounds in tissues can be monitored through their products of reaction with biomacromolecules. For the purpose of in vivo dose monitoring, hemoglobin (Hb) has been preferred to...Full Text Available

1993-03-01

310

The ageing of CANDU steam generator due to localized corrosion  

International Nuclear Information System (INIS)

The principal types of corrosion are presented which can occur in CANDU steam generator. There are also presented the operation conditions, the specifications referring to the water chemistry and the construction materials of Steam Generator, the factors that have a great influence on the corrosion behaviour during the whole exploitation period of this equipment. The most important elements of CANDU Steam Generator ageing management program are also discussed. (R. P.)

2001-09-17

311

Stress Corrosion Cracking Susceptibility of Beta Titanium Alloy 38-6-44: Candidate Alloy for Scout Torsion Bar.  

Science.gov (United States)

The threshold stress itensities for stress corrosion crack propagation in beta titanium alloy 38-6-44, Ti-3Al-8V-6Cr-4Mo-4Zr, has been determined in salt water and methanolic solutions. The alloy was immune to stress corrosion cracking in aqueous sodium c...

1974-01-01

312

Silicon effect on corrosion resistance of austenite stainless steels in strongly oxidizing media containing fluoride and phosphate admixtures  

International Nuclear Information System (INIS)

Paper estimates the corrosion resistance and studies the character of dissolving of silicon-bearing austenite stainless steels in strongly oxidizing media containing phosphate and fluoride admixtures. Corrosion behaviour of the studied steels is determined to depend essentially on the content of admixture or alloying silicon, as well as, on their phase composition in many respects determined by the thermal treatment condition. Refs. 22, figs. 1, tabs. 2.

313

Pitting corrosion on a copper canister; Gropfraetning paa kopparkapsel  

Energy Technology Data Exchange (ETDEWEB)

It is demonstrated that normal pitting can occur during oxidizing conditions in the repository. It is also concluded that a new theory for pitting corrosion has to be developed, as the present theory is not in accordance with all practical and experimental observations. A special variant of pitting, based on the growth of sulfide whiskers, is suggested to occur during reducing conditions. However, such a mechanism needs to be demonstrated experimentally. A simple calculational model of canister corrosion was developed based on the results of this study. 69 refs, 3 figs.

1996-02-01

314

On the effect of misch metal addition on corrosion behaviour of aluminium in inorganic and organic acids  

Energy Technology Data Exchange (ETDEWEB)

The effect of small misch metal additions (0.25 to 1 wt.%) on the corrosion behaviour of aluminium was studied through electrochemical polarization in 0.1 N inorganic and organic acids at room temperature. It has been observed that rare earth addition improves the corrosion resistance of aluminium. (orig.).

1992-10-01

315

Mechanism of denting corrosion  

International Nuclear Information System (INIS)

The rapid corrosion of carbon steels in high temperature, acid chloride solutions is shown to be rate limited by the anodic reaction, 3Fe + 4H_2O = Fe_3O_4 + 8H"+ + 8e"-, based on experiments which find that the corrosion rate in 0.1M NiCl_2 solution has an activation energy of 60 kJ/ mole and is unaffected by adding NaCl or by replacing NiCl_2 with PtCl_4. (author).

316

Manual corrosion  

Energy Technology Data Exchange (ETDEWEB)

In the aim to fight against tubes corrosion of geothermal wells which exploit the aquifer of Dogger reservoir in the Parisian basin, injection of corrosion inhibitors in the geothermal fluid has been generalized since 1989 by using an additive injection tube in the bottom of the well, allowing the protection of the two wells from the geothermal doublet. 3 annexes. 46 refs. 13 tabs. 9 figs.

1994-09-01

317

Introduction to corrosion of bioimplants  

British Library Electronic Table of Contents (United Kingdom)

The review provides a general idea about the types of metallic alloys and the pure metals used as implant materials in dental and orthopedic surgery. Their corrosive behavior in both real solutions and various media that model human biological fluids is described. Based on the literature data, it is concluded that multicomponent alloys containing titanium, niobium, zirconium, tungsten, molybdenum, aluminum, and silicon are the most resistant to corrosion. Implants made of different types of stainless steel are preferred when manufacturing orthopedic devices for short-term use.

2011-01-01

318

Growth model and on-line measurement of pitting corrosion on carbon steel  

Energy Technology Data Exchange (ETDEWEB)

A growth model of pitting corrosion of carbon steel in cooling water systems was developed on microscopic observations of pits and electrochemical studies. Results of pitting corrosion measurements in laboratory and field conditions with the model, using a newly developed electrochemical device, are discussed. For an actual heat exchanger up to a year operation, the values of pitting depth estimated were in good agreement with the measured values.

1996-12-01

319

General corrosion of ALLOY 800 in high temperature water and its prevention  

Energy Technology Data Exchange (ETDEWEB)

General corrosion behavior of ALLOY 800 in high temperature water was studied in relation to its surface film structure. The surface film formed in water was found to decrease the corrosion rate of ALLOY 800. This film is composed of Ni ferrite, and can be obtained by oxidation in air or steam. Based on these results, air or steam oxidation treatment to inhibit Ni and Co release of ALLOY 800 into high temperature water is proposed. (author).

1989-10-01

320

General corrosion of ALLOY 800 in high temperature water and its prevention  

International Nuclear Information System (INIS)

General corrosion behavior of ALLOY 800 in high temperature water was studied in relation to its surface film structure. The surface film formed in water was found to decrease the corrosion rate of ALLOY 800. This film is composed of Ni ferrite, and can be obtained by oxidation in air or steam. Based on these results, air or steam oxidation treatment to inhibit Ni and Co release of ALLOY 800 into high temperature water is proposed. (author).

321

Effect of environmental variables on localized corrosion of high-performance container materials  

Energy Technology Data Exchange (ETDEWEB)

Electrochemical cyclic potentiodynamic polarization (CPP) experiments were performed on several candidate high-performance waste package container materials to evaluate their susceptibility to localized corrosion in aqueous environments relevant to the potential underground high-level nuclear waste repository. This paper presents the results of this study showing the effects of chloride ion (Cl) concentrations, pH, temperature, and electrochemical potential scan rate on the pitting corrosion behavior of these materials.

1997-01-01

322

Criteria for the selection of corrosion inhibitors for Arctic and subsea high velocity flowlines  

Energy Technology Data Exchange (ETDEWEB)

Qualifying corrosion inhibitors for use in high velocity multiphase flowlines in arctic or subsea environments is discussed. The tests include high velocity flow loop corrosion tests, pumpability through 0.125 (0.318 cm) inch capillary at low temperatures, compatibility with Nylon 11, emulsion tendency testing, and partitioning characteristics. Laboratory and field data show the importance for using the above criteria for inhibitor selection.

1999-11-01

323

Corrosion resistance of zinc coatings on depleted uranium and uranium alloys  

Energy Technology Data Exchange (ETDEWEB)

Simulated atmospheric corrosion studies were performed to determine the corrosion protection provided by galvanized zinc coatings on depleted uranium, U-0.75 Ti alloy, and U-6 Nb alloys. The accelerated ASTM tests consisted of exposing the galvanized samples to aqueous and aqueous chloride environments. The test results showed that anodic protection was provided by the electronegative zinc coatings on uranium and uranium alloys. Treating zinc with chromate conversion coatings also provided more protection.

1985-01-27

324

Corrosion resistance of metals in hot hydroxide solutions  

International Nuclear Information System (INIS)

Effect of hydroxide nature, concentration and temperature on corrosion resistance of domestic steels and alloys to hot NaOH, KOH, LiOH solutions is considered. It is ascertained that by corrosion growth in relation to stainless steels and nickel alloys, the hydroxides are placed in the following sequence: LiOH

325

Corrosion product role on the inhibition of Zn alloy electrodeposit corrosion  

Energy Technology Data Exchange (ETDEWEB)

Electrodeposited Zn alloys with Fe group metals are known to be more resistant than pure Zn. However, the role of the corrosion products on the corrosion inhibition is not considered up to date. The aim of the present work was to examine the composition of corrosion products, which form on the Zn and Zn alloy surfaces under atmospheric corrosion conditions up to 3 year of exposure, trying to correlate it with the differences in their corrosion resistance. Zn corrosion products have been characterized by X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). Corrosion film composition was determined to depend on the sample exposure she, as well on the coating type. During the initial exposure stages oxide film was found to be the principal reaction product (XPS data), which in marine station consists from hydroxide phase ...

1998-12-31

326

Corrosion of materials. A tabular survey. Korrosionsverhalten von Werkstoffen. Eine tabellarische Uebersicht  

Energy Technology Data Exchange (ETDEWEB)

This compact book of tables attempts to give practicians a survey of the corrosion behaviour of common structural and coating materials. Corrosion resistances are presented for steels, alloys, plastics, elastomers, graphite, glasses, and stoneware in environments of NaOH, HNO{sub 3}, SO{sub 2}, ZnCl{sub 2}, NH{sub 3}, H{sub 2}O{sub 2}, ethyl chloride, sodium acetate, and many others. (MM).

1990-01-01

327

Characterization of tube support alloys  

International Nuclear Information System (INIS)

The involvement and relationship of carbon steel corrosion products in the tube denting phenomenon promoted an intensive research effort to: 1) understand, reproduce, and arrest the denting process, and 2) evaluate alternative tube support materials to provide additional corrosion resistance. The paper summarizes a corrosion testing program for the verification of type 405 stainless steel under acid or all volatile treatment conditions.

1985-03-01

328

CORIS[sup (TM)]: A knowledge based system for pitting corrosion. CORIS trademark : Wissensbasiertes System zur Lochkorrosion  

Energy Technology Data Exchange (ETDEWEB)

A knowledge based system for pitting corrosion is presented. It can be used for material selection for specific pitting corrosion conditions or to check the suitability of a chosen material. The user can enter his own knowledge. The expert system is an integration of traditional expert system technology and neural networks. (orig.)

1993-10-01

329

Method and device for the graduated charging of finely-particulate solid substances into an industrial furnace. Verfahren und Vorrichtung zum dosierten Einfuehren feinkoerniger Feststoffe in einen Industrieofen  

Energy Technology Data Exchange (ETDEWEB)

The invention concerns a method for the graduated introduction of finely-particulate and especially pulverously-particulate solid substance, in particular coal dust, from a pressurised proportioning tank containing a supply of solid matter into an industrial furnace with several supply points, in particular a shaft furnace such as a blast furnace or a cupola furnace, the solid matter being conveyed to the individual supply points in a flow of carrier gas heavily charged with solid matter, through a separate transport line for each supply point, the carrier gas being conveyed to the lower end section of the proportioning tank in a current which causes a local loosening in the lower section of the supply of solid matter, with the transport lines opening into the loosened area, whilst the proportioning tank that contains the solid matter is weighed continuously, the actual weight of the proportioning tank ...

1987-09-09

330

Isothermal refuelling of natural gas vehicles with condensed natural gas CNG; Isotherme Betankung von Erdgasfahrzeugen mit komprimiertem Erdgas CNG  

Energy Technology Data Exchange (ETDEWEB)

CNG vehicles suffer from an uncontrolled temperature rise of the gas inside the tank during the filling process and heat exchange with the environment leads to variable filling levels. A partly filled tank reduces the range of CNG vehicles and works as a impediment to the spreading of environmentaly more friendly CNG vehicles. The increase of the pressure inside the tank combined with a prolongation of the filling time beyond three minutes can reduce the deficit of the filling process. For economic reasons the time required for refuelling should be as short as possible without the need to operate the filling station with a critical pressure. To meet this target the current technique requires further improvement. (orig.) [Deutsch] Die betriebliche Praxis bei Tankvorgaengen von Erdgasfahrzeugen zeigt, dass waehrend des Tankvorganges die Temperatur des getankten Erdgases im Fahrzeugtank ansteigt. Waehrend und nach Beendigung ...

1998-07-01

331

Commissioning and operation of new liquid poison injection based shut down system in TAPP-3 and 4  

International Nuclear Information System (INIS)

Shut Down System - 2 (SDS - 2) of TAPP-3 and 4 works on the principle of rapid injection of gadolinium nitrate poison solution into bulk moderator in calandria using high pressure helium to shut down the reactor. This is a new system, in the context of Indian PHWRs, designed, engineered, commissioned and being operated in TAPP-3 and 4. The system design incorporates passive features such as floating polyethylene ball with ball-ball seat arrangement and locked open isolation ball valves with key interlock arrangement. This arrangement eliminates active valves downstream of poison tanks during SDS - 2 actuation. A series parallel arrangement of fast acting pilot controlled air operated valves, which keep the high pressure helium isolated from poison tanks in poised state, are the only active components. During commissioning and initial period of operation of TAPP-4, problems were encountered and were resolved by suitable modifications and the ...

2006-11-13

332

The THIRST chemistry module as a tool to determine optimal steam generator corrosion control strategies  

Energy Technology Data Exchange (ETDEWEB)

As part of a coordinated program, AECL is developing a set of tools to aid with the prediction and management of steam generator performance. Although stress corrosion cracking (of Alloy 800) has not been detected in any operating steam generator, for life management it is necessary to develop mechanistic models to predict the conditions under which stress corrosion cracking is plausible. Therefore, constant extension rate tests were carried out for Alloy 800 under various steam generator crevice chemistry conditions at applied potentials. These tests were designed to evaluate the stress corrosion cracking susceptibility of Alloy 800 under CANDU( steam generator operating conditions. Based on the experimental results, the recommended electrochemical corrosion potential/pH zone for Alloy 800 determined by electrochemical polarization measurements was verified with the respect of stress ...

2006-07-01

333

Surface modification on magnesium alloys by coating with magnesium fluorides  

Energy Technology Data Exchange (ETDEWEB)

A new technique has been developed for improving corrosion resistance on magnesium alloys. Specimens of AZ31 magnesium alloy were dipped into molten salt of NaBF{sub 4} at 723 K for various times, and then cooled, rinsed with water, and dried in air. Corrosion resistance in the surface treated specimens was evaluated by salt immersion test using 1% NaCl solution as a time for occurring filiform corrosion. On an un-treated AZ31 alloy, the time for starting the filiform corrosion was about 1.2 ks, while on the surface treated specimen, the time was prolonged into about 1300 ks. Moreover, the surface treated specimen showed corrosion resistance in low pH solutions, such as 1% HNO{sub 3} and HCl solutions. (orig.)

2005-07-01

334

Sodium hideout studies in steam generator crevices  

International Nuclear Information System (INIS)

The steam generator availability is one of the important problems encountered during the pressurized water nuclear plant operation. Various kinds of corrosion phenomena were observed in the past. These phenomena result from the concentration of impurities mainly in three locations in the steam generators: the tubesheet crevices, the tube support plate crevices, and the sludge pile. Corrections were made in the design and the materials used but a number of steam generators suffer or will suffer from corrosion processes inducing in many cases forcing their replacement. In order to prevent or to retard the corrosions several laboratories have performed experiments to reproduce and to study the corrosion processes. The first step of the degradation is the concentration of chemical species. A method using /sup 24/Na as a radioactive tracer was used to establish the concentration kinetics of caustic which was ...

335

Sodium gluconate as corrosion and scale inhibitor of ordinary steel in simulated cooling water  

Energy Technology Data Exchange (ETDEWEB)

The effect of sodium gluconate anion (SG) on the corrosion and scale inhibition of ordinary steel in simulated cooling water has been studied using weight loss, polarisation curves, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) techniques. SG was studied in concentration from 10{sup -4} M to 10{sup -1} M. Results obtained reveal that SG perform excellently as corrosion and scaling inhibitor for ordinary steel in simulated cooling water. An increase of SG concentration leads to the increase of the corrosion potential towards the positive direction. The inhibition efficiency was a low temperature dependence. The inhibitor mechanism was treated as an adsorption process according to Langmuir adsorption isotherm. The SEM/EDAX data show that was a corrosion and scale inhibitor.

2008-06-15

336

Sodium gluconate as corrosion and scale inhibitor of ordinary steel in simulated cooling water  

British Library Electronic Table of Contents (United Kingdom)

The effect of sodium gluconate anion (SG) on the corrosion and scale inhibition of ordinary steel in simulated cooling water has been studied using weight loss, polarisation curves, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) techniques. SG was studied in concentration from 10-4M to 10-1M. Results obtained reveal that SG perform excellently as corrosion and scaling inhibitor for ordinary steel in simulated cooling water. An increase of SG concentration leads to the increase of the corrosion potential towards the positive direction. The inhibition efficiency was a low temperature dependence. The inhibitor mechanism was treated as an adsorption process according to Langmuir adsorption isotherm. The SEM/EDAX data show that was a corrosion and scale inhi...

2008-01-01

337

Sialon sintering product excellent in liquid sodium corrosion resistance  

International Nuclear Information System (INIS)

A sialon sintering product of the present invention comprises #beta#'-sialon grains and less than 2vol% of a grain boundary phase, and a relative density of the sintering product is greater than 98%. It exhibits a high temperature strength of greater than 500Mpa at 650degC and shows such high corrosion resistances that the reduction of the volume due to corrosion is less than 0.5mg/cm"2 in a liquid sodium immersion test, and the corrosion of the grain boundary is not observed. Accordingly, there can be provided a sialon sintering product excellent in corrosion resistance in a liquid sodium circumstance while keeping the high temperature strength as an excellent characteristic of the sialon sintering product. (T.M.).

1995-04-19

338

Pitting corrosion of stainless steels; Lochkorrosion an nichtrostenden Staehlen  

Energy Technology Data Exchange (ETDEWEB)

Stainless steels can get pitting corrosion in halide containing solution, which make them a big risk in industrial production. Many investigations were made in the past in order to understand processes involved in pitting corrosion, pit initiation and pit growth. Results about the influence of alloying elements, their contents, the state of the structure, the condition of the surface, the content of chloride, the temperature, the pH-value, the velocity of flow and of the oxidizer on the chloride induced pitting corrosion of passive stainless steels are presented. Electrochemical measurements and the application of surface analytical methods (SEM, SAM, XPS) with high lateral resolution are carried out. A part of the samples received a diffusion annealing in order to obtain reproducible results. Pitting Resistance Equivalents (PRE) - Pitting Index - with different multipliers are given and discussed critical. An ...

1996-01-01

339

Passivity of high corrosion resistant Cu-Al-Sn alloys  

Energy Technology Data Exchange (ETDEWEB)

In a work studying the corrosion and tarnishing properties of a variety of copper alloys, the alloy Cu-A110-Sn5 was found to show an excellent corrosion resistance in neutral solutions, where copper and most conventional Cu alloys are covered by thick nonprotective surface layers. The passive films formed on this alloy were characterized with electrochemical and photoelectrochemical methods. The pH dependence of the passivation and of the photocurrent behavior of the Cu-A110-Sn5 alloy clearly indicates that the passivity of this alloy in neutral solutions is due to a formation of passive film enriched with aluminum oxide. At corrosion potential a strong increase in the corrosion resistance with time is due to a gradual enrichment of the surface with aluminum oxide. This can be seen in the photocurrent spectra which change from cooper-type to aluminum-type with time. At higher applied potentials the ...

1993-10-01

340

Long term corrosion on T91 and AISI1 316L steel in flowing lead alloy and corrosion protection barrier development: Experiments and models  

British Library Electronic Table of Contents (United Kingdom)

Considering the status of knowledge on corrosion and corrosion protection and especially the need for long term compatibility data of structural materials in HLM a set of experiments to generate reliable long term data was defined and performed. The long term corrosion behaviour of the two structural materials foreseen in ADS, 316L and T91, was investigated in the design relevant temperature field, i.e. from 300 to 550degreeC. The operational window of the two steels in this temperature range was identified and all oxidation data were used to develop and validate the models of oxide scale growth in PbBi. A mechanistic model capable to predict the oxidation rate applying some experimentally fitted parameters has been developed. This model assumes parabolic oxidation and might be used for de...

2011-01-01

341

Investigation into corrosion fatigue of stainless steels in high concentrated sulfuric acid  

Energy Technology Data Exchange (ETDEWEB)

Four commercial stainless steels (mat. Nos. 1.4539, 1.4586, 1.4571 and 1.4462) were tested in 96% and 90% sulfuric acid of 80/sup 0/C as to their corrosion fatigue strength by subjecting notched round bars to the rotary bending test. At the same time, the efficiency of anodic protection was examined. With all four steels, the alternating bending strength obtained in the air is essentially reduced. The semiaustenitic steel Nr. 1.4462 shows a lower corrosion fatigue strength than the three austenitic steels. Although making the corrosion fatigue strength of steels better calculable, anodic protection proves insufficient to completely prevent notched round bars from corrosion fatigue in concentrated sulfuric acid.

1982-09-01

342

Influence of self-doped poly(aniline-co-4-amino-3-hydroxy-naphthalene-1-sulfonic acid) on corrosion inhibition behaviour of iron in acidic medium  

British Library Electronic Table of Contents (United Kingdom)

This paper presents the corrosion inhibition performance of soluble self-doped copolymers of aniline and 4-amino-3-hydroxy-naphthalene-1-sulfonic acid synthesized by chemical oxidative polymerization method. The corrosion inhibition behaviour of the copolymers in 1.0M HCl has been evaluated using Tafel Extrapolation method and electrochemical impedance spectroscopy (EIS) which was also used to propose the mechanism besides surface morphology. The results showed that the copolymer film exhibited the significant shifting in the corrosion potential and greater charge transfer resistance. The corrosion inhibition efficiency was found to increase from 50% to 90% by increasing the concentration of copolymer from 10 to 70mg/l in HCl medium. Moreover, the copolymer showed the larger degree of surf...

2011-01-01

343

Evaluation method for corrosion resistance of zirconium alloy  

International Nuclear Information System (INIS)

The present invention concerns a method of evaluating corrosion resistance of a zirconium alloy easily and in a short period of time. An anode polarization curve of the zirconium alloy is measured to obtain an anode polarization curve expressed by logarithm. The curve is converted to a potential-current density curve expressed by absolute values. The peak area in the curve of the converted potential-current density is indicated by numerical values. Further, the corrosion resistance of the zirconium alloy is evaluated based on the peak area converted into the numerical values as a reference. This method is based on the finding that the peak area has a close relation with nodular corrosion resistance, and the corrosion resistance can be judged with respect to a specific zircaloy-2. (T.M.).

1993-03-26

344

Corrosion resistance of Ultra-Low-Carbon 19% Cr-11% Ni stainless steel for nuclear fuel reprocessing plants in nitric acid  

International Nuclear Information System (INIS)

An Ultra-Low-Carbon 19% Cr-11% Ni Stainless Steels used in nuclear fuel reprocessing plants where highly corrosion resistance in nitric acid is required has been developed. This steel has optimized the chemistry composition to decrease inclusions and deformation-induced martensitic transformation. The formation of deformation-induced martensite has the potential danger of accelerating corrosion in nitric acid. In this paper, effects of cold reduction and martensitic transformation on corrosion resistance of Ultra-Low-Carbon Stainless Steels in nitric acid are discussed. The developed steel showed excellent corrosion resistance during long-term exposure to nitric acid. (author).

345

Corrosion resistance characteristic of aluminium bronze containing chromium and zirconium  

International Nuclear Information System (INIS)

There are reported the results of corrosion resistance investigation of aluminium bronzes, containing about 8 and 10% of aluminium and modifying quantities of zirconium. The tests of corrosion resistance were carried out in synthetic seawater, in 3% NaCl aqueous solution and in 10% H_2SO_4 aqueous solution, with reference to industrial bronze BA93 (CuAl9Fe3). The bronzes were tested in an annealed, hardened, tempered state and after plastic hot working. The conclusion is that corrosion resistance of aluminium bronzes, especially against selective corrosion, depends more on material structure, resulted form heat treatment, than on chemical composition. (author). 6 refs, 8 figs, 6 tabs.

346

Corrosion and scale processes and their inhibition in simulated cooling water systems by monosaccharides derivatives  

British Library Electronic Table of Contents (United Kingdom)

A study of the ordinary mild steel/cooling water interface, with and without inhibitor, was carried out using electrochemical impedance spectroscopy (EIS). EIS spectra in uninhibited medium reveal that a layer of corrosion and scale products is formed naturally and evolves with the immersion time. Monosaccharides derivatives were used as corrosion inhibitors. Most of them exhibit good behaviour against corrosion of ordinary steel in simulated water systems. Their inhibiting efficiency increases with concentration rise and depends on molecular structure especially -OH groups' position on two adjacent carbons and their number. In addition, the effect of MoO4^2^- on the corrosion inhibition in the presence of the best inhibitor was also studied by EIS. The addition of MoO4^2^- enhanced the in...

2009-01-01

347

Ceramic linings beat coal plant's abrasion/corrosion problems  

Energy Technology Data Exchange (ETDEWEB)

A combination of erosion and corrosion at the Victoria Junction coal preparation plant in Sydney, Nova Scotia was causing serious problems. Schedule 80 mild steel pipes were starting to fail as well as some quarter-inch steel plates in the lauders and chutes. Some corrosion tests were carried out and the high chloride level in the process water was felt to be the single most important contribution to the corrosion problem. Cast basalt was selected as a solution to the pipe wear problem. Three different types of abrasion/corrosion-resistant tiling - basalt tiles, kalceram tiles and ceramic tiles were well suited to the chloride conditions at this plant.

1985-07-01

348

An overview of beta titanium alloy environmental behavior  

International Nuclear Information System (INIS)

Stemming from their unique combination of elevated strength, low density, and good overall corrosion resistance, beta titanium alloys have become attractive candidate materials for critical, high-stress, components in corrosive services. An overview of the comparative corrosion resistance of beta alloys to conventional alpha and alpha/beta titanium alloys in common industrial and aerospace service environments generally reveals attractive behavior depending on the environment and alloy composition and, in some cases, alloy condition. Expanded performance windows are especially noted for the molybdenum-rich beta alloys, particularly in regard to resisting reducing acids, stress corrosion, and high temperature localized chloride attack, along with hydrogen and oxidation resistance. Where applicable, implications of this enhanced corrosion performance on current and perspective beta ...

1993-02-21

349

Accelerated aging corrosion tests for buried metal structures  

Energy Technology Data Exchange (ETDEWEB)

It is necessary to identify those measurable soil parameters which dictate the severity of the corrosion problem for coated irons and steels. When this is done, meaningful accelerated aging tests can be designed to validate the reduced corrosion rate for the planned coating. The following discussion introduces the important concepts and measurement parameters in the (a) design of accelerated aging tests, and (b) evaluation of the planned installation site for corrosion potential. Certain combinations of soil oxidation reduction potential (ORP) or electric potential (Eh), acidity (pH), fertilizer, water table, and soil hydraulic conductivity can result in severe corrosion of buried steel/iron vessels. If there are power lines nearby, additional loss of vessel material to the soil will occur. These factors are discussed.

1996-10-01

350

A state-of-the art report on the investigation of the various corrosion models for zirconium-based alloy  

Energy Technology Data Exchange (ETDEWEB)

The desire to increase uranium utilization and to minimize spent fuel storage requirements provides an incentive to extend the average fuel rod discharge burnup to about 70,000MWd/MTU. For these higher burnups data are needed to determine if waterside corrosion of the cladding may be a life-limiting feature of fuel rod design. It is apparent that many factors can influence waterside corrosion, and these need to be better understood in order to minimize corrosion at these higher target burnups. The objective of this report is to review published data relevant to the corrosion of Zircaloy under PWR operating conditions. (author). 100 refs., 4 tabs., 21 figs.

1999-02-01

351

Topical Report ''Corrosion Evaluation of LLW2 Skid-B Weld Failure Mechanisms (44139-92)  

Energy Technology Data Exchange (ETDEWEB)

An independent investigation of pipe welding leaks from the Low-Level Waste 2 (LLW2) Skid-B System for the possibilities of improper welding (IW), microbiologically influenced corrosion (MIC), sensitization, chloride pitting corrosion (CPC), and intergranular stress corrosion cracking (IGSCC) was conducted. The results show the prevailing mechanisms that caused the leaks are identified as IW, CPC, and the improper selection of weld filler material for the base metals in an environment of the North Plateau underground water. These is no evidence of MIC, sensitization, or IGSCC. The chloride pitting corrosion mechanism that took place at all the welds are also described. All the pipelines were replaced with polyvinyl chloride (PVC) for cost saving and the LLW2 Skid B System has been successfully operating since 1999. This report summarizes the findings and recommendations associated with preventive ...

2001-05-31

352

Oxide induced corrosion on the welded stainless steels SS 2352 and 2353; Oxidbetingad korrosion i svetsar hos de rostfria staalen SS 2352 och 2353  

Energy Technology Data Exchange (ETDEWEB)

The pitting corrosion properties have been investigated in welded and unwelded condition by polarization tests in sodium chloride solutions. The two steels were TIG welded without adding welding material and as shielding on the bottom side argon gas containing 2, 26 or 99 ppm oxygen was used. In some tests low breakthrough potentials were received, without discovering any pitting corrosion in the specimen surfaces. The unwelded SS 2352 steel had a critical (lowest) pitting temperature (CPT) of 5 degrees C in the more concentrated solution. For the same steel with weld pitting corrosion was obtained at 5 degrees C, which was the lowest temperature for the tests. Thus the CPT value was lower than 5 degrees C, but by looking at the pitting corrosion potentials the following conclusion could be drawn: Welding with higher oxygen content in the shielding gas implied lower pitting ...

1991-09-16

353

In situ corrosion studies on selected high level waste packaging materials under simulated disposal conditions in rock salt formations  

International Nuclear Information System (INIS)

This paper reports about in-situ corrosion studies on selected materials for long-term resistant high-level waste (HLW) packagings acting as a barrier in a rock salt repository. The materials (Ti 99.8-Pd, Hastelloy C4 and five iron-base materials) were investigated in heated boreholes in the Asse salt mine under simulated HLW disposal conditions prevailing in normal operation of repository and in certain accident scenarios. The experiments under normal operating conditions were performed at temperatures of 120 deg. C to 210 deg. C (vertical temperature profile in the boreholes) without and with gamma irradiation (3#centre dot#10"2 Gy/h, Co-60 source) within the framework of the German/US Brine Migration Test. In these experiments only small amounts of migrated brine inclusions (NaCl-rich) from the rock salt were present as corrosion medium. In the experiments carried out under simulated accident conditions with intrusion of larger amounts of ...

1993-02-01

354

Prevention of pitting corrosion on copper tubes in central hot water supply systems by UV photochemical decomposition of residual chlorine  

Energy Technology Data Exchange (ETDEWEB)

After confirming that residual chlorine in tap water, which is regarded as one of the major cause of pitting corrosion, can be decomposed/removed by the irradiation of UV light, effect of dechlorinated water obtained based on this principle on the prevention of pitting corrosion, generation and growth, of the copper tubing was investigated by a corrosion test simulated the actual system in high buildings. (1) Low pressure type mercury lamp easily decompose/remove the residual chlorine. (2) If the dechlorinated water is supplied from the initial stage of copper tube usage, potential of the copper tube remains at the level of 100 mV/SCE and the generation of pitting corrosion is not observed. (3) Even when pitting corrosion is already found, switching to dechlorinated water in the midway reduces the potential of the copper tube down to 50 - 70 mV level, at the same time completely ...

1988-03-25

355

Photocorrosion of passive films on titanium in sulfuric acid  

Energy Technology Data Exchange (ETDEWEB)

Passive films formed anodically on titanium (Ti) plates in 0.5 M sulfuric acid were corroded in aqueous solutions of H{sub 2}SO{sub 4} in the dark and under illumination of a 250-W mercury lamp. The corrosion depth was determined by calculating the thickness of the oxide layers from interference patterns of reflection spectra in the visible region. Corrosion was observed at pH {le} 3, with the corrosion rate increasing exponentially with decreasing pH and achieving a maximum value at pH {approximately} 1. Photocorrosion generally was quicker than corrosion occurring in the dark in all cases (i.e., open-circuit, short-circuit, bias conditions) and increased under anodic polarization of the oxide electrode together with the photocurrent. Corrosion occurring in the dark decreased very weakly under anodic polarization. Long-term corrosion experiments indicated the ...

1995-03-01

356

Limit of pitting corrosion at high-alloyed special steels and NiCrMo alloys in chloride solution; Die Lochkorrosionsbegrenzung bei hochlegierten Sonderedelstaehlen und NiCrMo-Legierungen in Chloridloesung - Einflussfaktoren und Ausmass  

Energy Technology Data Exchange (ETDEWEB)

The phenomenon of the limit of pitting corrosion in direction to positive potentials is studied by potentiokinetic polarization after a jump in the transpassive range and by potentiostatic tests at technical wrought materials and at model alloys of the systems NiCrMo and NiMo in CaCl{sub 2} solution in the concentration range 1 to 9 mol/l chloride at pH-values of 1 to 9 at temperatures of 30 to 110 C. Surface-analytical investigations gives in connection with knowledges from anodic polarization studies directions to the mechanism of the limit of pitting corrosion. Ranges of the limit of pitting corrosion are obtained at materials with a Mo content above 6.5% and contents of chloride of the media above 2 mol/l chloride. Increasing temperatures, increasing contents of chloride and sulfate shift the potential of the limit of pitting corrosion being always above 0.2 V (SCE) at potentiostatic determination ...

2001-08-01

357

Influence of suspended solids on pitting corrosion of carbon steel in cooling water. Tansoko no koshoku ni oyobosu reikyaku suichu no kendaku busshitsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

A large amount of industrial water is used for cooling the various process fluids in the petroleum purification factories as well as petroleum chemistry factories. Consequently, a lot of heat exchangers as the necessary constitutional instruments are made of carbon steel. Due to the most of the corrosions of the carbon steel occurring in such cooling water systems are pitting corrosions, the inhibition thereof is extremely important for the elongation of the life of the plants and the stable operation. In this paper, the influences of water quality fractions on pitting corrosion of carbon steel in cooling water circumstance are examined aiming at the fouling in the cooling water. The fouling in the cooling water does not only increase the amount of occurrence of pitting corrosion but also accelerates the progress of pitting corrosion enlarging the rust due to its deposition near the ...

1993-08-15

358

Evaluation of new corrosion-resistant superheater tubing in high-efficiency waste-to-energy plants  

Energy Technology Data Exchange (ETDEWEB)

Field corrosion tests were conducted on eight single tube materials and two welded overlay materials in three typical Japanese waste incineration plants in an effort to develop new corrosion-resistant superheater tubes capable of functioning efficiently under temperature and pressure conditions of 500 C and 100 kgf/cm{sup 2}-g in high-efficiency waste-to-energy (WTE) plants. Austenitic alloys containing higher concentrations of chromium, nickel, and molybdenum [Cr + Ni + Mo] showed excellent corrosion-resistant properties, and the new alloys JHN24 and HR30M showed good corrosion resistance. Different corrosion rates found in each of the three plants were explained by differences in operating conditions, such as gas temperature, concentration of molten salts resulting from chlorine (Cl) content of deposits, heavy metal (zinc oxide [ZnO] + lead oxide [PbO]) content, etc. It was ...

1998-07-01

359

Electrochemical roles of precipitates on uniform corrosion and hydrogen pickup of zirconium alloys, 1. Roles on corrosion  

Energy Technology Data Exchange (ETDEWEB)

Substantial roles of precipitates such as Zr-Fe-Cr type intermetallic compounds on uniform corrosion and hydrogen pickup of zirconium alloys in pure water autoclave tests were investigated from an electrochemical point of view. This paper describes the roles on corrosion. A corrosion test on precipitate-containing and precipitate-free materials made from pure zirconium and a small quantity of iron and chromium, rest potential measurements on an intermetallic compound of Zr(FeCr){sub 2} and zirconium matrix, and a galvanic coupling test of those were performed. Results showed that corrosion behavior of zirconium alloys could be attributed to the electrochemical properties of intermetallic compounds precipitated in each alloy. Namely, the cathodic and anodic polarization characteristics were associated with anodic protection provided by the precipitates on the alloys and the precipitates degradation in ...

2000-07-01

360

Electrochemical roles of precipitates on uniform corrosion and hydrogen pickup of zirconium alloys, 1. Roles on corrosion  

International Nuclear Information System (INIS)

Substantial roles of precipitates such as Zr-Fe-Cr type intermetallic compounds on uniform corrosion and hydrogen pickup of zirconium alloys in pure water autoclave tests were investigated from an electrochemical point of view. This paper describes the roles on corrosion. A corrosion test on precipitate-containing and precipitate-free materials made from pure zirconium and a small quantity of iron and chromium, rest potential measurements on an intermetallic compound of Zr(FeCr)_2 and zirconium matrix, and a galvanic coupling test of those were performed. Results showed that corrosion behavior of zirconium alloys could be attributed to the electrochemical properties of intermetallic compounds precipitated in each alloy. Namely, the cathodic and anodic polarization characteristics were associated with anodic protection provided by the precipitates on the alloys and the precipitates degradation in the ...

2000-07-01

361

Effects of nitrogen on the passivity and the pitting corrosion of stainless steels; Stainless ko no fudotai to koshoku ni oyobosu chisso no eikyo  

Energy Technology Data Exchange (ETDEWEB)

Described herein are effects of nitrogen dissolved in steel on passivity and pitting corrosion, as one of the major corrosion phenomena observed in stainless steel. Mechanisms involved in controlling pitting corrosion by nitrogen are also discussed. Nitrogen contained in austenic stainless steel is concentrated in the surface area, in particular in the vicinity of the interface between the passive film and metal matrix. Nitrogen tends to decrease critical current density in an acid, when it is added to steel of high critical current density (approximately 1mA/cm{sup 2} or higher). This phenomenon is considered to result from accumulation of nitrogen preferentially in the surface area to prevent dissolution of steel. Nitrogen dissolved in the austenic phase improves resistance of the steel to pitting corrosion. This phenomenon is considered to result from controlled decrease in pH level during the ...

1998-09-15

362

Effect of Glycoletherdiaminetetraacetic acid on corrosion inhibition of stainless steel. Glycoleetherdiamin shisakusan ni yoru stainless ko no fushoku yokusei koka  

Energy Technology Data Exchange (ETDEWEB)

An analysis was made on corrosion suppression mechanism of glycoletherdiaminetetraacetic acid (GEDTA) film made from GEDTA on stainless steel, and its corrosion inhibition effect. Results of analysis using IR spectrum, IR-ATR spectrum, {sup 1} HNMR spectrum, and ESCA spectrum indicated the deposition of the GEDTA film is a chemical deposition. In polarization tests at pH = 5 and 7, both polarization curves shifted to the constant current density side, showing suppression effect in reactions at both pH. When the corrosion environment is made severer, such as to pH = 2 and 4, the corrosion suppression effect of GEDTA became more distinctive. A ferroxyl test identified very little difference between untreated and treated materials. In a chemical pitting test, because oxidant and corrosive anion coexist in the test solution, and GEDTA is stable against corrosive ...

1990-12-20

363

Corrosion test and service result of materials used for fuel injection nozzles in marine diesel engines  

Energy Technology Data Exchange (ETDEWEB)

Corrosion test, as a material selection test method of nozzle to be used in the marine diesel engine, was adopted and discussed. Due to the heightening in output power and lengthening in stroke of the marine diesel engine, the fuel injection nozzle became so severe in working condition that the nozzle tip became in lift 1/6 to 1/18 time as long as that of short stroke type in past. Then upon investigating cause of damage, the damage was confirmed to be mainly caused by the high temperature sulfidization corrosion. Then by preparing 20 kinds of candidate test piece and making sulfidization corrosion test in accordance with the high temperature corrosion test procedure, corrosiveness was evaluated through change in weight between before and after testing. As a result of testing, three kinds of test piece, inclusive of high Ni-Cr-Al alloy's, showed a high ...

1989-06-15

364

Correlation between designed wall thickness of gas pipelines and external and internal corrosion processes; Adequacao de espessura de parede projetada em funcao de processos de corrosao externa e interna em gasodutos  

Energy Technology Data Exchange (ETDEWEB)

Corrosion control on gas pipelines plays an important role on the assessment of pipeline integrity and reliability. In many countries a great extension of buried pipelines is used on transport and distribution systems. This extension will be certainly increased in a near future due to the increasing consumption of natural gas. Inadequate corrosion control can drive to pipeline failures, bringing up the possibility of accidents in populated or environmental protected areas, bringing together severe economical, legal and environmental consequences. Corrosion is frequently considered as a natural and inevitable phenomenon. Based upon this assumption, some recommendations are included on design standards of gas pipelines in order to compensate its detrimental effect. The aim of this work is to present a review of the correlation between external corrosion process and the guidelines established during the ...

2004-07-01

365

Two-dimensional natural convective heat transfer analysis in an open cavity and its application to KMRR  

International Nuclear Information System (INIS)

Natural convection flow is established in KMRR (Korea Multi-Purpose Research Reactor) reflector tank at the loss of reflector circulator. To simulate the reflector tank natural convection flow with high temperatures at the inner shell and bottom plate due to nuclear heating, experimental and numerical studies in an open cavity with 'L' type heated wall made by the combination of a vertical and horizontal plate were performed. It was confirmed through these studies that the heat transfer rates were highest at the lower region of the vertical plate and the inlet region of horizontal plate and comparatively high at the middle portion of both plates. The heat transfer rate distribution of this trend shows a desirable trend for the effective natural convection cooling of KMRR reflector tank. It was also confirmed that the average Nusselts numbers at the 'L' type heated wall were lower than those obtained from the existing ...

1991-10-26

366

Kinetics of absorption of trace iodine vapor in aqueous solution of sodium hydroxide, (2)  

International Nuclear Information System (INIS)

A liquid column was used for the experiments reported in Part 1. However, it only gives the observation of the effect of fast reaction because the liquid flow was controlled to uniform laminar flow and the contact is limited to short time of around 10 ms. In practical absorbing operation, turbulence is involved in liquid flow, and the residence time for contact is long. Hence, the absorption of trace iodine in the purified air has been experimented by using a constant interface area type stirred absorption tank. Prior to the experiment, the characteristics of the absorption tank was investigated by conducting pure carbon dioxide absorption test with purified water. It gave the conclusion that the tank was sufficiently usable for fundamental researches. In short contact time absorption, the iodine dissolved and absorbed in liquid phase is affected by reaction of hypoiodous acid and poly-iodide ion formation due to hydrolysis ...

1978-01-01

367

Batch test equilibration studies examining the removal of Cs, Sr, and Tc from supernatants from ORNL underground storage tanks by selected ion exchangers  

Energy Technology Data Exchange (ETDEWEB)

Bench-scale batch equilibration tests have been conducted with supernatants from two underground tanks at the Melton Valley Storage Tank (MVST) Facility at Oak Ridge National Laboratory (ORNL) to determine the effectiveness of selected ion exchangers in removing cesium, strontium, and technetium. Seven sorbents were evaluated for cesium removal, nine for strontium removal, and four for technetium removal. The results indicate that granular potassium cobalt hexacyanoferrate was the most effective of the exchangers evaluated for removing cesium from the supernatants. The powdered forms of sodium titanate (NaTiO) and cystalline silicotitanate (CST) were superior in removing the strontium; however, for the sorbents of suitable particle size for column use, titanium monohydrogen phosphate (TiHP {phi}), sodium titanate/polyacrylonitrile (NaTiO-PAN), and titanium monohydrogen phosphate/polyacrylonitrile (TiP-PAN) gave the best results and were about ...

1995-06-01

368

Actinide, strontium, and cesium removal from Hanford radioactive tank sludge  

International Nuclear Information System (INIS)

A pretreatment flowsheet was tested for separating key radionuclide components from the sludge stored in one of the high level waste tanks (B-110) at the Hanford Site; this sludge resulted primarily from the bismuth phosphate process, which was one of the three major plutonium separation processes used at Handford. This test involved (1) washing with water, (2) caustic leaching, (3) acid dissolution, (4) separation of transuranic elements (TRUs) by extraction with octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide(CMPO), (5) separation of Sr by extraction with di-t-butylcyclohexano-18-crown-6, (6) separation of Cs from the acid-dissolved sludge solution by treatment with ammonium molybdophosphate (AMP), and (7) separation of Cs from the sludge wash and caustic leach solutions by ion exchange using a phenol-formaldehyde resin (CS-100). The results of the radionuclide separation steps indicated that the proposed flowsheet is a viable approach to pretreating ...

369

Waste monitoring system for effluents  

Energy Technology Data Exchange (ETDEWEB)

The waste monitoring system in use at Los Alamos National Laboratory`s Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system.

1995-07-01

370

Spectroscopic detection  

Energy Technology Data Exchange (ETDEWEB)

In embodiments, spectroscopic monitor monitors modulated light signals to detect low levels of contaminants and other compounds in the presence of background interference. The monitor uses a spectrometer that includes a transmissive modulator capable of causing different frequency ranges to move onto and off of the detector. The different ranges can include those with the desired signal and those selected to subtract background contributions from those with the desired signal. Embodiments of the system are particularly useful for monitoring metal concentrations in combustion effluent.

2003-01-01

372

Off-line and on-line-monitoring of power transformers using the transfer function method  

Energy Technology Data Exchange (ETDEWEB)

The transfer function concept is well known as an additional method to evaluate the impulse test of power transformers in the test laboratory. Another application for the transfer function method is monitoring of transformers in service. Thereby, Off-line and On-line monitoring can be realized. Both kinds of monitoring are demonstrated with on-site measurements on a power transformer in service.

1996-12-31

373

Monitoring Coastal Marshes for Persistent Saltwater Intrusion  

Science.gov (United States)

Primary goal: Provide resource managers with remote sensing products that support ecosystem

2009-01-01

377

Environmental #gamma# dose rate monitoring system around Guangdong Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This article introduces the composition, monitoring methods and working principles of environmental #gamma# dose rate continuous monitoring system at Guangdong Daya Bay Nuclear Power Station. The #gamma# dose rate monitoring status after modification of measurement conditions is introduced too.

380

Coastal Marsh Monitoring for Persistent Saltwater Intrusion  

Science.gov (United States)

This viewgraph presentation reviews NASA's work on the project that supports the Gulf of Mexico

2008-01-01

381

Animal Brucellosis in the Kyrgyz Republic  

International Science & Technology Center (ISTC)

Epizootological Monitoring of Brucellosis and Methods of its Eradication in the Kyrgyz Republic

383

Evaluation of SCC susceptibility of alloy 800 under CANDU SG secondary-side conditions  

Energy Technology Data Exchange (ETDEWEB)

As part of a coordinated program, AECL is developing a set of tools to aid with the prediction and management of steam generator performance. Although stress corrosion cracking (of Alloy 800) has not been detected in any operating steam generator, for life management it is necessary to develop mechanistic models to predict the conditions under which stress corrosion cracking is plausible. Therefore, constant extension rate tests were carried out for Alloy 800 under various steam generator crevice chemistry conditions at applied potentials. These tests were designed to evaluate the stress corrosion cracking susceptibility of Alloy 800 under CANDU( steam generator operating conditions. Based on the experimental results, the recommended electrochemical corrosion potential/pH zone for Alloy 800 determined by electrochemical polarization measurements was verified with the respect of stress ...

2006-07-01

384

Evaluation of SCC susceptibility of alloy 800 under CANDU SG secondary-side conditions  

International Nuclear Information System (INIS)

As part of a coordinated program, AECL is developing a set of tools to aid with the prediction and management of steam generator performance. Although stress corrosion cracking (of Alloy 800) has not been detected in any operating steam generator, for life management it is necessary to develop mechanistic models to predict the conditions under which stress corrosion cracking is plausible. Therefore, constant extension rate tests were carried out for Alloy 800 under various steam generator crevice chemistry conditions at applied potentials. These tests were designed to evaluate the stress corrosion cracking susceptibility of Alloy 800 under CANDU( steam generator operating conditions. Based on the experimental results, the recommended electrochemical corrosion potential/pH zone for Alloy 800 determined by electrochemical polarization measurements was verified with the respect of stress ...

2006-11-26

385

C-106 tank process ventilation test  

Energy Technology Data Exchange (ETDEWEB)

Project W-320 Acceptance Test Report for tank 241-C-106, 296-C-006 Ventilation System Acceptance Test Procedure (ATP) HNF-SD-W320-012, C-106 Tank Process Ventilation Test, was an in depth test of the 296-C-006 ventilation system and ventilation support systems required to perform the sluicing of tank C-106. Systems involved included electrical, instrumentation, chiller and HVAC. Tests began at component level, moved to loop level, up to system level and finally to an integrated systems level test. One criteria was to perform the test with the least amount of risk from a radioactive contamination potential stand point. To accomplish this a temporary configuration was designed that would simulate operation of the systems, without being connected directly to the waste tank air space. This was done by blanking off ducting to the tank and connecting temporary ducting and an inlet air ...

1998-07-20

386

Vacuum leak problem in low energy of pelletron  

International Nuclear Information System (INIS)

During unit wise conditioning of unit 8, the vacuum started deteriorating inside the tube after a spark. The RGA reading was taken and it was found out that residual gas inside tube was sulphur hexafluoride. A leak was detected in second tube of unit number eight in between electrode 6 to 8. Leak was sealed with the sealant. Again leak check was done and no leak was found. The tank was closed and conditioning was started again. During the same unit number eight conditioning, leak developed again followed by a spark. So the damaged tube was replaced with a new accelerator tube. During the installation time the alignment of the machine was taken care. Again leak checking was done and the tube was baked properly. The tank was closed again and this particular unit was conditioned for about four days. The maximum voltage it has attained was 1.1 MV. (author)

387

The MiniBooNE detector technical design report  

Energy Technology Data Exchange (ETDEWEB)

The MiniBooNE experiment [1] is motivated by the LSND observation, [2] which has been interpreted as {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, and by the atmospheric neutrino deficit, [3,4,5] which may be ascribed to {nu}{sub {mu}} oscillations into another type of neutrino. MiniBooNE is a single-detector experiment designed to: obtain {approx} 1000 {nu}{sub {mu}} {yields} {nu}{sub e} events if the LSND signal is due to {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, establishing the oscillation signal at the > 5{sigma} level as shown in Fig. 1.1; extend the search for {nu}{sub {mu}} {yields} {nu}{sub e} oscillations significantly beyond what has been studied previously if no signal is observed; search for {nu}{sub {mu}} disappearance to address the atmospheric neutrino deficit with a signal that is a suppression of the rate of {nu}{sub {mu}}C {yields} {mu}N events from the expected 600,000 per year; measure the oscillation parameters as shown in Fig. 1.2 if ...

2003-04-18

388

Subcritical measurements with a cylindrical tank of Pu-U nitrate  

Energy Technology Data Exchange (ETDEWEB)

This series of measurements with a mixed Pu-U nitrate solution (280 g Pu/liter, 180 g U/liter) in a 35.54-cm-diam cylindrical tank provides a wide variety of experimental data for subcritical configurations that can be used to verify calculational methods and nuclear data. The Pu contained 7.85 wt% {sup 240}Pu and the uranium was natural uranium. The measurements performed were: inverse count rate, prompt neutron decay constants, inverse kinetics, and frequency analysis by the {sup 252}Cf source driven method. These data are presented in sufficient detail that the results of the experiments can be calculated directly. For purposes of extrapolating to the delayed critical height the ratio of spectral densities was linear with height and thus provided the best estimate of critical height.

1997-04-01

389

Solids distribution in tall tanks  

British Library Electronic Table of Contents (United Kingdom)

Abstract Uniformly distributing slurry solids in -tall- (-2:1 aspect ratio) process vessels is a significant challenge in the chemical industry. This work determined the performance of various multi-tier agitation systems in uniformly distributing a settling solid throughout water in a -tall- laboratory vessel. It used a 0.445-m ID Plexiglas tank, with a slurry height of 0.889-m, to determine how solids distribution changes with solids loading (wt.%), impeller speed, and impeller type. Some impeller types uniformly distributed the solids even before energy input exceeded 1.00-W/kg. Significantly higher energy improved solids distribution little because flow within the vessel eventually became choked.

2011-01-01

390

Rocky Mountain Arsenal, Basin F liquid storage tank spill, draft risk assessment  

Energy Technology Data Exchange (ETDEWEB)

The scope of this RA is limited to the evaluation of potential human health risks associated with a failure event of a tank containing Basin F liquid. Section 1.0 contains an introduction to the health risk assessment. Section 2.0 describes the site history, location, and land use. Section 3.0 provides a brief description of exposure pathways and potention receptors. Section 4.0 describes the sources of data used and identifies chemicals of concern. Section 5.0 discusses the toxicity of concern. Section 6.0 explains the methods used for calculation of carcinogenic risks and the noncarcinogenic hazard indexes. Section 7.0 describes uncertainties inherent in the current methodology used to determine potential human health risks. Section 8.0 presents a summary of results and conclusions. Section 9.0 includes the references cited.

1993-04-01

391

Radon concentration measurements at water reservoirs  

International Nuclear Information System (INIS)

Ground water is treated in the Czech Republic so that small water tanks are built above each water source to serve the primary ground water treatment; water so pretreated is then concentrated in large basins for subsequent treatment. Some water tanks where the first contact of the ground water with air takes place were selected as sites predisposed to radon accumulation. The examination was carried out near the town of Jihlava, where the bedrock contains slightly elevated radium concentrations. The average radon concentrations lay within the region of 2-4 kBq/m"3; the instantaneous values, however, exhibited appreciable periodical variations during the day. The relatively high radon concentrations will not pose a marked hazard for the personnel because the employees only reside at the sites in question for 10 to 15 minutes within 2 days, not for the whole working day

1998-09-09

392

Measurement of liquid nitrogen level by radiation  

Energy Technology Data Exchange (ETDEWEB)

The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)

1995-07-01

393

Liquid radioactive waste discharges from B plant to cribs  

Energy Technology Data Exchange (ETDEWEB)

This engineering report compiles information on types and quantities of liquid waste discharged from B-Plant directly to cribs, ditches, reverse wells, etc., that are associated with B-Plant. Waste discharges to these cribs via overflow form 241-B, 241-BX, and 241-BY tank farms, and waste discharged to these cribs from sources other than B-Plant are discussed.Discharges from B-Plant to other cribs, unplanned releases, or waste remaining in tanks are not included in the report. Waste stream composition information is used to predict quantities of individual chemicals sent to cribs. This provides an accurate mass balance of waste streams from B-Plant to these cribs. These predictions are compared with known crib inventories as a verification of the process.

1996-05-29

394

Fuel cell hybrid taxi life cycle analysis  

British Library Electronic Table of Contents (United Kingdom)

A small fleet of classic London Taxis (Black cabs) equipped with hydrogen fuel cell power systems is being prepared for demonstration during the 2012 London Olympics. This paper presents a Life Cycle Analysis for these vehicles in terms of energy consumption and CO2 emissions, focusing on the impacts of alternative vehicle technologies for the Taxi, combining the fuel life cycle (Tank-to-Wheel and Well-to-Tank) and vehicle materials Cradle-to-Grave. An internal combustion engine diesel taxi was used as the reference vehicle for the currently available technology. This is compared to battery and fuel cell vehicle configurations. Accordingly, the following energy pathways are compared: diesel, electricity and hydrogen (derived from natural gas steam reforming). Full Life Cycle Analysis, usin...

2011-01-01

395

Device for energy-saving heating of fuel in the fuel supply for an internal combustion engine  

Energy Technology Data Exchange (ETDEWEB)

The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat exchanger to be short-circuited depending on the fuel temperature.

1981-02-10

396

Concentration of Melton Valley Storage Tank surrogates with a wiped film evaporator  

Energy Technology Data Exchange (ETDEWEB)

This report describes experiments to determine whether a wiped film evaporator (WFE) might be used to concentrate low-level liquid radioactive waste (LLLW). Solutions used in these studies were surrogates that contain no radionuclides. The compositions of the surrogates were based on one of Oak Ridge National Laboratory`s (ORNL`s) Melton Valley Storage Tanks (MVSTs). It was found that a WFE could be used to concentrate LLLW to varying degrees by manipulating various parameters. The parameters studied were rotor speed, process fluid feed temperature and feed rate, and evaporator temperature. Product consistency varied from an unsaturated liquid to a dry powder. Volume reductions up to 68% were achieved. System decontamination factors were consistently in the range of 10{sup 4}.

1994-08-01

397

A novel domestic electric water heater model for a multi-objective demand side management program  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a novel domestic hot water heater model to be used in a multi-objective demand side management program. The model incorporates both the thermal losses and the water usage to determine the temperature of the water in the tank. Water heater loads are extracted from household load data and then used to determine the household water usage patterns. The benefits of the model are: (1) the on/off state of the water heater and temperature of the water in the tank can be accurately predicted, and (2) it enables the development of water usage profiles so that users can be classified based on usage behaviour. As a result, the amount of ancillary services and peak shaving that can be achieved are accurately predictable and can be maximized without adversely affecting users. (author)

2010-12-15

398

/sup 252/Cf-source-driven neutron noise measurements of subcriticality for a slab tank containing aqueous Pu-U nitrate  

Energy Technology Data Exchange (ETDEWEB)

In order to study nuclear criticality safety related to the development of fast breeder technology, /sup 252/Cf-source-driven neutron noise analysis measurements were performed with a Pu-U nitrate solution in a slab tank of various heights and thickness varying 11.43 cm to 19.05 cm. The results and conclusions of these experiments are (1) a capability to measure the subcriticality of a multiplying system of slab geometry to a k/sub eff/ as low as 0.7 was demonstrated, (2) calculated neutron multiplication factors agreed with those from the experiments within approx.0.02, and (3) the applicability of the method for plutonium solution systems was demonstrated. This paper describes measurements in which the height of the slab was varied for a fixed thickness and the thickness varied for a fixed height, which are the first applications of this measurement method to slab geometry.

1987-08-01

399

Remote monitoring of a coal waste impoundment in West Virginia. Open file report Oct 78-Sep 81  

Energy Technology Data Exchange (ETDEWEB)

This report addresses remote monitoring of coal waste impoundments for stability. Existing automated geotechnical monitoring systems are described and reviewed along with details of instruments suitable for such systems. An impoundment in West Virginia, which was in the construction stage, was instrumented and monitored between July 1979 and May 1981. Sensors that measure surface and subsurface parameters including settlement, horizontal deflection, surface tilt, pore water pressure, seepage, pond level, and meteorlogical parameters were installed. Recommendations for improving and expanding the capabilities of the monitoring system are given.

1982-02-01

400

Proceedings of the Indo-British workshop on remote sensing of environment in mining field  

Energy Technology Data Exchange (ETDEWEB)

16 papers are presented covering: remote sensing - an aid to environment management; remote sensing application; monitoring environmental changes over iron ore mining areas; monitoring and management of environmental degradation due to geological factors; use of Landsat multispectral scanner data in environmental monitoring; geotechnical engineering problems with abandoned limestone mines; photogrammetric monitoring of mining environment; slope monitoring in open cast mines using close range remote sensing method; geobotanical remote sensing and mineral prospecting; geographical information in study of geo-environment through remote sensing; and alteration mapping in cuprite mining district.

1993-01-01

401

Broadband Local Area Network security monitoring--Magnovox CATV Systems Inc. Digital System Sentry product evaluation  

Energy Technology Data Exchange (ETDEWEB)

Use of a broadband Local Area Network (LAN) for transmission of classified and secure unclassified information requires monitoring capabilities which are sensitive to discrete segments of the network frequency spectrum. A viable monitoring system must be capable of detecting possible intrusion attempts or network malfunctions and alerting operating and security personnel. This report documents the results of an evaluation of the Magnavox CATV Systems Inc. Digital System Sentry software for network monitoring. Recommendations are made on its possible future role in broadband LAN security monitoring throughout the Nuclear Weapons Complex.

1991-01-01

402

Investigation of corrosion experienced in a spray calciner/ceramic melter vitrification system  

Energy Technology Data Exchange (ETDEWEB)

After periodic testing of a large-scale spray calciner/ceramic melter vitrification system over a 2-yr period, sufficient corrosion was noted on various parts of the vitrification system to warrant its disassembly and inspection. A majority of the 316 SS sintered metal filters on the spray calciner were damaged by chemical corrosion and/or high temperature oxidation. Inconel-601 portions of the melter lid were attacked by chlorides and sulfates which volatilized from the molten glass. The refractory blocks, making up the walls of the melter, were attacked by the waste glass. This attack was occurring when operating temperatures were >1200/sup 0/C. The melter floor was protected by a sludge layer and showed no corrosion. Corrosion to the Inconel-690 electrodes was minimal, and no corrosion was noted in the offgas treatment system downstream of the sintered metal filters. It is ...

1980-08-01

403

Innovative coke oven gas cleaning system for retrofit applications. Quarterly environmental monitoring report No. 2, July 1, 1991--September 30, 1991  

Energy Technology Data Exchange (ETDEWEB)

The EMP consists of a Compliance Monitoring Sampling Program and a Supplemental monitoring Sampling Program. The Compliance Monitoring Sampling Program will be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Project and during a summer and a winter period following the successful Startup and Operational phase of the completed Project. compliance monitoring consist of conducting all the sampling and observation programs associated with existing required Federal, State, and Local Regulations, Permits and Orders. These include air, water, and waste monitoring and OSHA and NESHAP monitoring. The Supplemental Monitoring Program will also be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Demonstration Facility and during a ...

1992-09-21

404

Groundwater surveillance plan for the Oak Ridge Reservation  

Energy Technology Data Exchange (ETDEWEB)

US Department of Energy (DOE) Order 5400.1 requires the preparation of environmental monitoring plans and implementation of environmental monitoring programs for all DOE facilities. The order identifies two distinct components of environmental monitoring, namely effluent monitoring and environmental surveillance. In general, effluent monitoring has the objectives of characterizing contaminants and demonstrating compliance with applicable standards and permit requirements, whereas environmental surveillance has the broader objective of monitoring the effects of DOE activities on on- and off-site environmental and natural resources. The purpose of this document is to support the Environmental Monitoring Plan for the Oak Ridge Reservation (ORR) by describing the groundwater component of the environmental surveillance program for the DOE ...

1994-07-01

405

Diagnosing mechanical changes: A test of the machine condition monitoring concept  

Energy Technology Data Exchange (ETDEWEB)

BC Hydro recently conducted a demonstration test of a bearing condition monitor. The test, at the 529-MW Kootenay Canal project, proved the ability of the monitor to detect machine condition faults. The capability to detect changing conditions during normal operation of hydroelectric machines gives hydro plant owners the opportunity to anticipate needed maintenance and ultimately to reduce the number of equipment failures. BC Hydro intends to install bearing condition monitors, as well as windings monitors, brushgear monitors, environmental monitors, and other selected systems in as many as 46 of its hydro generators. BC Hydro analyzed forced outages between 1985 and 1989 in its hydro system to identify which parts of a generating unit resulted in the highest number of hours of outage. From there, the utility has formulated a concept for a machine condition ...

1993-05-01

406

The effect of annealing parameter on corrosion resistance of Zircaloy-2  

International Nuclear Information System (INIS)

The effects of equal #SIGMA#Ai for different combinations of the annealing temperature and annealing time on corrosion resistance and evolution of precipitates of Zircaloy-2 were investigated. Nodular corrosion resistance in the out-of-pile corrosion test was degraded with increasing #SIGMA#Ai only when it was increased by extending the annealing time at 894 K but did not depend on #SIGMA#Ai which was increased by raising the annealing temperature for a constant annealing time of 2.5 h. Extensive observation and micro-analysis of precipitates by analytical electron microscope (AEM) suggested the cause of degradation of nodular corrosion resistance to be the remarkable increase in volume fraction of Si-containing precipitates such as Zr_3Si and Zr_2Si, which were observed more frequently in large #SIGMA#Ai only when it was increased by extending the annealing time at 894 K. On the other hand, uniform ...

407

Suppression of pitting corrosion with passive film modification on type 304 stainless steel by ultra-violet light irradiation; Shigaikoshosha ni yoru Type 304 stainless ko no fudotai himaku kaishitsu to koshoku yokusei  

Energy Technology Data Exchange (ETDEWEB)

In this study, the effects of 325nm wavelength ultraviolet light irradiation on pitting corrosion behavior of type 340 stainless steel in a neutral chloride solution are studied. Further, the change of passive film with the light irradiation is analyzed using x-ray photoelectron spectroscopy. The mains results obtained therefrom are stated below. Pitting potential can be shifted in noble direction by the ultraviolet light irradiation. The effect of ultraviolet light irradiation is ore prominent in the pitting corrosion process than that in the passive film formation. The result of the analysis in terms of the birth and death stochastic probability process shows that pitting corrosion rate is decreased remarkably by the ultraviolet light irradiation at the formation of passive film, while the repassivation is slightly expedited by the ultraviolet light irradiation. On the other hand, the repassivation rate is increased a ...

1998-06-20

408

Pitting corrosion resistance of high alloy OCTG in ferric chloride solution  

International Nuclear Information System (INIS)

The effects of alloying elements and precipitated phases on the corrosion rate of high alloy OCTG in the ferric chloride solution have been evaluated. The corrosion rate of Fe-Cr-Ni-Mo alloys without precipitated phases, e.g. carbides and sigma phase, can be estimated from the composition using the following equation: log(C.R.)=-0.144xPRE-7690/(273+T)+28.6 where C.R. is the corrosion rate in g/m/sup 2//hr; PRE is Cr+3Mo+16N in percent and T is the test temperature in "0C. The activation energies of the ferric chloride test are almost the same regardless of PRE or Ni content when no detrimental phase precipitates. When carbides or the sigma phase precipitate, the corrosion rate is higher and the activation energy is lowered. This suggests that secondary phases give preferential sites for initiation of pitting corrosion.

409

Pitting corrosion of Alloy 690 in thiosulfate-containing chloride solutions  

Energy Technology Data Exchange (ETDEWEB)

The effects of thiosulfate ion and solution pH on pitting corrosion of Alloy 690 in chloride solution were explored. Potentiodynamic polarization measurements were conducted to evaluate pitting corrosion susceptibility of Alloy 690 in these environments. The results showed that pitting corrosion occurred in the mill-annealed (1050 deg. C/5min) Alloy 690 in 1 wt% NaCl solution but not in 0.1 M Na{sub 2}S{sub 2}O{sub 3} solution. The value of pitting nucleation potential (E{sub np}) determined in 1 wt% NaCl solution (without Na{sub 2}S{sub 2}O{sub 3} ) increased with increasing solution pH value in the range of 2-10. The addition of Na{sub 2}S{sub 2}O{sub 3} to 1 wt% NaCl solution greatly affected the pitting corrosion behavior, which was dependent on concentration. The preformed nickel sulfide surface film due to the presence of Na{sub 2}S{sub 2}O{sub 3} caused Alloy 690 to become more susceptible to ...

2000-02-01

410

Oxidation and chromium depletion of Alloy 800 and 316SS by molten NaNO/sub 3/-KNO/sub 3/ at temperatures above 600/degree/C  

Energy Technology Data Exchange (ETDEWEB)

The corrosion behavior of Alloy 800 and Type 316 stainless steel in molten NaNO/sub 3/-KNO/sub 3/ was studied at temperatures from 605/degree/C to 630/degree/C. Corrosion behavior was significantly different from that previously reported in nitrate melts at temperatures up to 600/degree/C and involved a combination of oxidation, internal nitridation and sodium metallate formation. Corrosion kinetics, determined metallographically, switched from a parabolic to a linear rate equation as temperature increased. Corrosion was uniform and resulted in metal losses on the order of 100 micronsyear at 630/degree/C. Among the alloying elements, chromium was depleted from the alloy as the result of a basic fluxing process. The kinetic equations describing chromium depletion also changed from parabolic to linear with increasing temperature. The effect of the equilibrium chemistry of the melt on the ...

1987-01-01

411

NPP steam generator: materials and water-chemical regime  

International Nuclear Information System (INIS)

The main reasons of tube failures in steam generators (SG) are considered. 1.Stress corrosion craining which has 28% of SG (most of them have stainless steel tubes). 2. Corrosion loss of metal, which accounts for 24% of tubes (phosphate corrosion due to addition of PO into water). 3.Denting-peripheral pressing of tubes in the openings of the foundation plates by the corrosive products, which are formed on internal surface of drillings in the foundation plates made of carbon steel. 4.Separation of a plating layer on tube panels. 5.Dratting-corrosion. 6.Metal fatigue. A series of experiments were conducted to study the influence of material selection on tube reliability (stainless steel 304, inconel-600, mone-400, incalloy-800). The problem of increase of SG elements reliability is a complex one and can be solved by direct selection of material, proper control of water-chemical ...

412

Microsegregation-related pitting corrosion characteristics of AL-6XN superaustenitic stainless steel laser welds  

International Nuclear Information System (INIS)

Research highlights: #-># Welding parameters affect pitting corrosion resistance of AL-6XN laser welds. #-># Lower heat input laser welds correspond to higher critical pitting temperature. #-># Depletion of Mo and Cr at dendrite cores causes preferential pitting corrosion. #-># Local Mo level at dendrite cores dominates weld pitting corrosion susceptibility. #-># Lower heat input laser welds manifest lower degree of microsegregation of Mo. - Abstract: Pitting corrosion resistance of laser welds of AL-6XN superaustenitic stainless steel (SASS) was investigated in acidic chloride ion medium. It was found that the critical pitting temperature (CPT) of the laser welds increased with increasing welding speed or decreasing laser power. Pitting attack preferentially occurred at selective dendrite cores of the laser welds. Analytical electron microscope (AEM) microanalysis revealed that depletion ...

2010-10-01

413

Materials choices for the advanced LWR steam generators  

International Nuclear Information System (INIS)

Current light water reactor (LWR) steam generators have been affected by a variety of corrosion and mechanical damage degradation mechanisms. Included are wear caused by tube vibration, intergranular corrosion, pitting, and thinning or wastage of the steam generator tubing and accelerated corrosion of carbon steel supports (denting). The Electric Power Research Institute (EPRI) and the Steam Generator Owners Groups (I, II) have sponsored laboratory and field studies to provide ameliorative actions for the majority of the damage forms experienced to date. Some of the current corrosion mechanisms are aggravated or caused by unique materials choices or materials interactions. New materials have been proposed and at least partially qualified for use in replacement model steam generators, including an advanced LWR design. In so far as possible, the materials choices for the advanced LWR steam generator avoid ...

1987-11-15

414

Influence of thin oxide films on pitting corrosion of CrNi steels. Beeintraechtigung der Lochkorrosionsbestaendigkeit von CrNi-Staehlen durch duenne Oxidschichten  

Energy Technology Data Exchange (ETDEWEB)

Chloride-induced pitting corrosion of stainless steel (Materials No. 1.4301 and 1.4571) was investigated with the aid of chronopotentiostatic tests. Oxide films upon the surface (temper colours), addition of inhibitors (sulphate and nitrate) and temperature were the testing variables. Two different critical pitting potentials have been found, which give information on the potential ranges for stable passivity, latent and stable pitting corrosion. The results only indicate a small effect of Mo content of the material and test temperature. The inhibitors (sulphate and nitrate) have a marked effect. Specimens with a clean surface produced by pickling are markedly more resistant against pitting corrosion than specimens with a yellow temper colour, whereas the difference in corrosion resistance between yellow and blue films is relatively small. The width of the critical potential range for pitting ...

1993-09-01

415

Influence of sigma-phase formation on the localized corrosion behavior of a duplex stainless steel  

International Nuclear Information System (INIS)

Because of their austenitic-ferritic microstructures, duplex stainless steels offer a good combination of mechanical and corrosion resistance properties. However, heat treatments can lower the mechanical strength of these stainless steels as well as render them susceptible to intergranular corrosion (IGC) and pitting corrosion. In this study, a low-carbon (0.02%) duplex stainless steel is subjected to various heat treatments at 450 to 950 C for 30 min to 10 h. The heat-treated samples than undergo ASTM IGC and pitting corrosion tests, and the results are correlated with the microstructures obtained after each heat treatment. In the absence of Cr_2_3C_6 precipitation, #sigma#-phase precipitates render this duplex stainless steel susceptible to IGC and pitting corrosion. Even submicroscopic #sigma#-phase precipitates are deleterious for IGC resistance. Longer-duration heat treatments ...

1996-01-01

416

Influence of sea water on the fatigue strength and notch sensitivity of a plasma nitrided B-Mn steel  

Energy Technology Data Exchange (ETDEWEB)

Notched and smooth cylindrical plasma nitrided (PN) and quench and tempered (Q and T) steel specimens made of a B-Mn SS2131 ({approx}AISI 15B21H) steel have been exposed to constant amplitude plane reversed bending corrosion fatigue tests (R = -1) at 47 Hz in sea water. S - N curves show that sea water suppresses the fatigue limit and reduces fatigue strength (especially at long lives) of smooth and notched Q and T and PN specimens. Plasma nitriding improves the corrosion fatigue resistance of Q and T specimens; this is associated with the good corrosion resistance of {epsilon} and {gamma}`-phases, the enhancement of corrosion and fatigue by compressive residual stresses, and the consumption of H{sup +} ions during reduction of nitrogen. This improvement is more significant for smooth specimens and for long lives. Notch sensitivity of Q and T and PN specimens decreases with fatigue life. Pitting ...

1998-06-01

417

Influence of C, N and Nb contents on intergranular corrosion, stress corrosion cracking and mechanical strength of alloy 600  

International Nuclear Information System (INIS)

Dependence of C, N and Nb contents on intergranular corrosion (IGC), strews corrosion cracking (SCC) and mechanical strength of alloy 600 were examined. To evaluate the corrosion resistance of heat affected zone (HAZ), post weld heat treated specimens were used. To evaluate I G C and S C C susceptibility, Ferric Sulfate-Sulfuric Acid Test and High Temperature Water Test were used. Nb is effective as a stabilizer of C. Consequently to prevent corrosion attack on H A Z in high temperature water Nb should be added more than 100 ( % C - 0.005)% and to maintain mechanical strength, Nb should be added more than 3 + 75( %C + %N)%. Modified alloy 600 satisfying above condition was manufactured commercially and its various properties including weldability were confirmed to be excellent.

1985-12-01

418

FRAMATOME's continuous efforts to improve steam generator corrosion resistance  

International Nuclear Information System (INIS)

Construction of the French PWR nuclear program started in the early 70s, at the time a number of operating plants in the US were being affected by the first corrosion problems. Since, at that time, its construction program was in an early stage, FRAMATOME was able to make modifications on the first units to improve steam generator resistance to corrosion. For instance, full depth expansion of the tubes in the tube-sheet using an explosive process (Westex) was performed on Fessenheim 1 steam generators already installed on site. Later on, continuous operating experience was being obtained in the US, before startup of the French units. This allowed FRAMATOME to react rapidly and take immediate corrective actions at the design stage, during fabrication and sometimes even on site in order to mitigate the risk of corrosion in the steam generators. FRAMATOME is confident that the present design of its steam generator models, ...

419

Electrochemical corrosion behavior of AZ91D alloy in ethylene glycol  

Energy Technology Data Exchange (ETDEWEB)

The effect of concentration on the corrosion behavior of Mg-based alloy AZ91D was investigated in ethylene glycol-water solutions using electrochemical techniques i.e. potentiodynamic polarization, electrochemical impedance measurements (EIS) and surface examination via scanning electron microscope (SEM) technique. This can provide a basis for developing new coolants for magnesium alloy engine blocks. Corrosion behavior of AZ91D alloy by coolant is important in the automotive industry. It was found that the corrosion rate of AZ91D alloy decreased with increasing concentration of ethylene glycol. For AZ91D alloy in chloride >0.05 M or fluoride <0.05 M containing 30% ethylene glycol solution, they are more corrosive than the blank (30% ethylene glycol-70% water). However, at concentrations <0.05 for chloride or >0.05 M for fluoride containing ethylene glycol solution, some ...

2009-11-01

420

Effects of Cr content and the addition of Cr_2O_7"2"- ion on corrosion resistance of stainless steel in nitric acid solutions  

International Nuclear Information System (INIS)

A nitric acid solution containing Cr_2O_7"2"- ion is used for a corrosion test which simulates the condition in a nuclear fuel reprocessing plant. As the effect of Cr content on the corrosion resistance of stainless steel is not yet fully understood in that solution, the effects of Cr content in an alloy and that of Cr_2O_7"2"- ion in nitric acid on the corrosion rate were studied by using electro-chemical measurements. The increase of Cr content reduced the general corrosion rate in nitric acid solution without Cr_2O_7"2"- ion, however it increased that in nitric acid solution containing Cr_2O_7"2"- ion. It is considered that the reversal of the Cr content dependency is due to a rise of the corrosion potential caused by addition of Cr_2O_7"2"- ion to the potential region where a high Cr alloy shows higher anodic dissolution rate than a low Cr content alloy. (author).

421

Effect of micro segregation on pitting corrosion of SCS 14 austenitic stainless steel castings in sea water environments; SCS 14 osutenaitokei sutenresuchuko no kaisuichu deno koshoku kyodo ni oyobosu mikuro henseki no eikyo  

Energy Technology Data Exchange (ETDEWEB)

Austenitic stainless steel castings, such as SCS 13, SCS 14, which consists of {delta}/{gamma} duplex phase, are extensively used as structural material in seawater environments. It is known that SCS 14 involving 2wt% Mo is more resistant to pitting corrosion than SCS 13. In this paper, effects of Mo on the pitting corrosion are discussed in terms of microstructure of the material. The corrosion behavior of the materials with different {delta} ferrite contents and cleanlinesses have been evaluated by seawater exposure testing, electrochemical polarization, and TEM-EDX analysis. The results indicate that pits mainly nucleate at nonmetallic inclusions such as MnS and {delta}/{gamma} boundaries, and materials containing {delta} ferrite above 7vol% have high pitting corrosion resistance. The nucleation at {delta}/{gamma} boundaries is assumed to be due to the segregation of P. It is considered that because ...

1999-06-15

422

Effect of fluoride ion on the pitting corrosion of type 304 stainless steel in neutral NaCl solution. Chusei NaCl suiyoekichu ni okeru SUS 304 ko no koshoku ni oyobosu F[sup -] no eikyo  

Energy Technology Data Exchange (ETDEWEB)

Anode polarization measurement is performed in mixed solution of NaCl and NaF using SUS 304 steel to investigate whether F[sup -] promotes or inhibits pitting corrosion. Pitting corrosion does not occur in the solution of NaF only, but passive state is broken above a certain critical potential, resulting in overall dissolution. When anode polarization measurement is made in a solution of fixed concentration NaCl added with NaF, pitting corrosion is inhibited at a certain critical concentration. F[sup -] has no effect on corrosion potential in the solution up to this critical concentration. Overall dissolution occurs in the solution with higher concentration than the critical concentration, the current value at that time agrees with that in the solution of NaF alone, and no effect of Cl[sup -] is shown. The concentration range where pitting corrosion occurs and that where overall ...

1994-05-15

423

Corrosion of fluidized-bed boiler materials in synthetic flue gas  

Energy Technology Data Exchange (ETDEWEB)

Candidate materials for components of a fluidized-bed waste heat recovery system (FBWHRS) include plain carbon steel, types 405 and 316 stainless steel, and alloy 800. These materials were exposed to synthetic flue gas at anticipated FBWHRS temperatures and higher for 3000 h to determine corrosion rates. The synthetic flue gas was a combustion atmosphere to which Cl/sub 2/ and HCl were added. The projected annual corrosion rate for plain carbon steel is about 0.08 mm/year (0.003 in./year) at 250 to 290/sup 0/C, but it would exceed 0.5 mm/year (0.02 in./year) at 560/sup 0/C. The projected annual corrosion rates of the other materials were less than 0.25 mm/year (0.01 in./year) at the maximum test temperatures of 560, 660, and 665/sup 0/C for type 405, type 316, and alloy 800, respectively. These results indicate that corrosion of candidate FBWHRS materials will not be significant at anticipated operating ...

1983-11-01

424

Corrosion in drilling and well stimulation  

Energy Technology Data Exchange (ETDEWEB)

Corrosion in drilling and well stimulation is described in relation to acid corrosion inhibition, acid inhibitors, acetylenic inhibitors, synergistic blends, metallurgy, wellbore tubulars, coiled tubing, and high alloy tubular materials. Acidizing is a procedure for stimulating oil and gas wells. Factors that have an important influence on the reaction rate and the way in which acid reacts with rock include temperature, acid concentration, acid volume, injection velocity, acid viscosity, and fluid loss properties of the formation. The cost of drill pipe failures are $1 per fot of hole drilled, which is a significant fraction of the drilling cost. Steps in a test procedure are listed, as well as factors which determine the extent of acid corrosion in a given situation including acid type and strength, metal type, temperature, contact time; pressure, and volume/surface area ratio. Underbalanced drilling is a method for ...

1999-07-01

425

Boiler and HRSG tube failures. Lesson 2. Corrosion fatigue  

Energy Technology Data Exchange (ETDEWEB)

Fatigue damage occurs in general when a boiler tube is subject to repeat cyclic or fluctuating loading although the stress produced is below the material yield strength. The types of fatigue damage include, e.g., corrosion, thermal, mechanical, vibration, and creep fatigue. It is important to determine which form of fatigue is active, because measures to avoid repeat failures differ as the case arises. In this lesson, the focus is exclusively on corrosion fatigue. Corrosion fatigue occurs by the combined synergistic actions of cyclic loading and a corrosive environment. It is a discontinuous process with crack initiation and growth during transient periods. The excessive stresses may be caused during boiler operation by the restraint at tube attachments and by load changes (in particular during cold starts or forced cools) or during shutdown or restart of circulation boilers by thermal stratification of ...

2009-10-15

426

Behavior at under-film corrosion tips of Zn-Fe alloy coated steel sheets. Zn-Fe gokin mekki koban no tomakushita fushoku ni okeru fushoku sentanbu no kyodo  

Energy Technology Data Exchange (ETDEWEB)

From a macroscopic point of view, corrosion of Zn alloy coated steel sheet occurs by the coating preceding corrosion mechanism; microscopically, however, the coated layer corrosion velocity in the tip of corrosion is different. In order to find the main factors of under-film corrosion of Zn and Zn-Fe alloy coatings in the salt water spray atmospheric exposure test, the correlation between point inflation-exfoliation width and chlorine penetration behavior, point adhesion, and the difference in chlorine penetration behavior due to alloy coating components were investigated. Consequently, the following results were obtained: 1. The better correlation was observed between chlorine penetration distance and point inflation-point exfoliation width. 2. The durability of coating against chlorine penetration improved by increase in point adhesion and Zn content in the coating layer. 3. Zn-Fe ...

1990-09-01

427

A study of corrosion resistance behavior for W + C dual implanted H13 steel  

International Nuclear Information System (INIS)

The surface layer optimized in resistance of corrosion and wear has been obtained by W + C dual implantation on H13 steel. The electrochemical polarization measurements show that the peak current density I_D is increased and then saturated with increasing of voltage scanning loops. The I_D is 100 times smaller than that of H13 steel, and 2-3 times smaller than that of tungsten. Then influence of dual implantation order on corrosion resistance is also studied. The I_D for W_5C_8 implanted first with W is half of that for C_5W_5 implanted first with C. The corrosion resistance structure of the samples after corrosion is observed by SEM. The X-ray analysis indicates that the structure consists of disperse phases of WC, W_2C, FeW, Fe_2W, FeW_2C and iron carbides. It is shown from Auger analysis that the optimum complex layer for corrosion resistance consists of thin carbon film on ...

428

A comparison of the corrosion behaviour and hardness of steel samples (100Cr6) coated with titanium nitride and chromium nitride by different institutions using different deposition techniques  

Energy Technology Data Exchange (ETDEWEB)

Deposition of hard coatings may influence the mechanical properties of the bulk material and its corrosion resistance. In this work we study the hardness of the coated and the back side of 100Cr6 steel plates. Electrochemical corrosion tests were performed in O{sub 2}-saturated acetate buffer of pH 5.6 at 25degC. Chromium nitride and titanium nitride coatings prepared by different physical vapour deposition processes, such as arc, thermionic arc evaporation, magnetron sputtering and ion-beam-assisted deposition (IBAD) were compared. The results show that, for sufficient corrosion protection, chromium nitride layers have to be thicker than 500 nm. An increased nitrogen partial pressure in the evaporation chamber of the IBAD process improves the corrosion resistance significantly. The hardness of the substrates was reduced in the case of thermoionic arc evaporation only, indicating a deposition ...

1991-07-07

429

Summary of Initial Testing of SuperLig 644 at the TFL Ion Exchange Facility  

Energy Technology Data Exchange (ETDEWEB)

Research at the Savannah River Technology Center aided development of a technical design basis for a Waste Treatment Plant (WTP) to pre-treat and vitrify Hanford tank waste as part of the River Protection Project (RPP). The research addresses safety concerns, process optimization, and waste form compliance. This program will provide technical data to ensure that the process functions as it was designed and minimizes costs.

2001-04-17

430

Recent process developments at the SOMAIRE uranium mill  

International Nuclear Information System (INIS)

This paper reviews the mill flowsheet applied at the SOMAIR (Societe des Mines de l'Air) uranium mill in Niger. It focuses on the yellow cake quality improvements achieved by molybdenum and zirconium elimination through double yellow cake precipitation in tanks at first stage and through size/density control in a fluidized bed precipitator at second stage. Water saving aspects in the plant are also presented. (author)

2000-09-09

431

Projected radionuclide inventories of DWPF glass from current waste at time of production  

Energy Technology Data Exchange (ETDEWEB)

The Waste Acceptance Preliminary Specifications (WAPS) require that the DWPF estimate the inventory of long-lived radionuclides present in the waste glass, and report the values in the Waste Form Qualification Report. In this report, conservative (biased high) estimates of the radionuclide inventory of glass produced from waste currently in the Tank Farm are provided. In most cases, these calculated values compare favorably with actual data. In those cases where the agreement is not good, the values reported here are conservative.

1993-02-04

432

Project quality assurance plant: Sodium storage facility, project F-031  

International Nuclear Information System (INIS)

The Sodium Storage Facility Project Quality Assurance Plan delineates the quality assurance requirements for construction of a new facility, modifications to the sodium storage tanks, and tie-ins to the FFTF Plant. This plan provides direction for the types of verifications necessary to satisfy the functional requirements within the project scope and applicable regulatory requirements determined in the Project Functional Design Criteria (FDC), WHC-SD-FF-FDC-009.

433

Project W-314 Polyurea Special Protective Coating (SPC) Test Plan Chemical Compatibility and Physical Characteristics Testing  

Energy Technology Data Exchange (ETDEWEB)

This Test Plan outlines the testing to be done on the Special Protective Coating (SPC) Polyurea which includes: Tank Waste Compatibility, Decontamination Factor Testing, and Adhesion Strength Testing after a sample has been exposed to Radiation.

2001-01-15

434

Melter Disposal Strategic Planning Document  

Energy Technology Data Exchange (ETDEWEB)

This document describes the proposed strategy for disposal of spent and failed melters from the tank waste treatment plant to be built by the Office of River Protection at the Hanford site in Washington. It describes program management activities, disposal and transportation systems, leachate management, permitting, and safety authorization basis approvals needed to execute the strategy.

2000-09-25

435

Information systems definition architecture  

Energy Technology Data Exchange (ETDEWEB)

The Tank Waste Remediation System (TWRS) Information Systems Definition architecture evaluated information Management (IM) processes in several key organizations. The intent of the study is to identify improvements in TWRS IM processes that will enable better support to the TWRS mission, and accommodate changes in TWRS business environment. The ultimate goals of the study are to reduce IM costs, Manage the configuration of TWRS IM elements, and improve IM-related process performance.

1996-06-20

436

High level waste storage tanks 242-A evaporator S/RID phase II assessment report  

Energy Technology Data Exchange (ETDEWEB)

This document, the Standards/Requirements Identification Document (S/RID) Phase 2 Assessment Report for the subject facility, represents the results of a Performance Assessment to determine whether procedures containing S/RID requirements are fully implemented by field personnel in the field. It contains a summary report and three attachments; an assessment schedule, performance objectives, and assessments for selected functional areas.

1996-09-27

437

High level waste storage tank farms/242-A evaporator standards/requirements identification document phase 1 assessment report  

Energy Technology Data Exchange (ETDEWEB)

This document, the Standards/Requirements Identification Document (S/RID) Phase I Assessment Report for the subject facility, represents the results of an Administrative Assessment to determine whether S/RID requirements are fully addressed by existing policies, plans or procedures. It contains; compliance status, remedial actions, and an implementing manuals report linking S/RID elements to requirement source to implementing manual and section.

1996-09-30

438

Fluidic pumps  

International Nuclear Information System (INIS)

A fluidic pump comprises a two-diode pump having a first displacement vessel, a third diode connected to receive output from the two-diode pump through a delivery line and discharge to an outlet, and a second displacement vessel connected to the delivery line. There is a feed tank at a greater height than the two-diode pump, and a drive unit for alternately pressurising and venting the first and second displacement vessels. The drive pressure required to operate the pump can be of the order of half that for a single stage 2-diode pump. (author).

1988-05-19

439

Experimental verification of caustic-side solvent extraction for removal of cesium from tank waste.  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this report are: to demonstrate complete CSSX process flowsheet (proof of concept)--decontamination factor {ge} 40,000, and concentration factor {approx}15; Scientific and technical issues evaluated--stage efficiency, temperature control, hydraulic performance, long time (multi-day) operation, short-term shutdown, effect of solids, and recovery from Cs moving through strip section.

2001-09-21

440

Determination of reactor kinetic parameters in a two-core reactor  

Energy Technology Data Exchange (ETDEWEB)

The kinetic parameters, ..cap alpha.. the coupling coefficient and tau-bar the mean neutron transit time have been determined using a reactor oscillator on the coupled-core of the Queen Mary College research reactor. By using correlation techniques it has proved possible to use detectors small enough to be inserted in the fuel tanks. It is shown that the simplified Baldwin model with one-group diffusion theory is inadequate to describe the kinetic behaviour and the experimentally-determined parameters are dependent upon the positioning of the detectors.

1982-01-01

441

B Plant treatment, storage, and disposal (TSD) units inspection plan  

Energy Technology Data Exchange (ETDEWEB)

This inspection plan is written to meet the requirements of WAC 173-303 for operations of a TSD facility. Owners/operators of TSD facilities are required to inspection their facility and active waste management units to prevent and/or detect malfunctions, discharges and other conditions potentially hazardous to human health and the environment. A written plan detailing these inspection efforts must be maintained at the facility in accordance with Washington Administrative Code (WAC), Chapter 173-303, ``Dangerous Waste Regulations`` (WAC 173-303), a written inspection plan is required for the operation of a treatment, storage and disposal (TSD) facility and individual TSD units. B Plant is a permitted TSD facility currently operating under interim status with an approved Part A Permit. Various operational systems and locations within or under the control of B Plant have been permitted for waste management activities. Included are the following TSD units: Cell 4 Container Storage Area; B ...

1996-04-26

442

An approach to software quality assurance for robotic inspection systems  

International Nuclear Information System (INIS)

Software quality assurance (SQA) for robotic systems used in nuclear waste applications is vital to ensure that the systems operate safely and reliably and pose a minimum risk to humans and the environment. This paper describes the SQA approach for the control and data acquisition system for a robotic system being developed for remote surveillance and inspection of underground storage tanks (UST) at the Hanford Site.

1993-11-14

443

Tubular packs Mo-AlN-Mo: long-term thermal and corrosion resistance  

International Nuclear Information System (INIS)

Study results on long-term thermal and corrosion resistance of packs with electro-insulation layer of aluminium nitride are presented. Structural changes of nitride ceramics and contact zones between metal and ceramics are considered. It is shown that multilayer metallo-ceramic packs, manufactured by gas-phase technology have high electro- and thermophysical properties, high thermal and corrosion resistance relative to cesium vapor, vacuum density as well as high thermo-resistance. 8 refs., 4 figs.

444

Stress corrosion cracking susceptibility of #beta# titanium alloy 38-6-44  

International Nuclear Information System (INIS)

The threshold stress intensities for stress corrosion crack propagation in beta titanium alloy 38-6-44, Ti3Al-8V-6Cr-4Mo-4Zr, has been determined in salt water and methanolic solutions. The alloy was immune to stress corrosion cracking (SCC) in aqueous sodium chloride solutions (marine atmosphere). However, in methanolic solutions, the alloy was very susceptible to SCC. This marked susceptibility in methanolic solutions can be mitigated by the addition of an inhibitor: sodium nitrate. Crack extension in the alloy was transgranular and failure occurred by brittle quasi-cleavage in methanolic solutions.

445

Revised minimum nitrite concentration for ESP  

Energy Technology Data Exchange (ETDEWEB)

Nitrite is to be used to inhibit pitting corrosion during Extended Sludge Processing (ESP) at the Savannah River Plant. The required nitrite concentrations are expressed as a function of the slurries' nitrate ion concentration and temperature. In the most dilute slurries, the nitrite inhibitor requirement is independent of the nitrate ion concentration and depends only on the temperature of the waste. The nitrate-independent concentration ensures that there is sufficient inhibitor, in sludge slurries whose nitrate has been depleted by radiolysis, to prevent pitting corrosion induced by other corrosive anions (e.g., sulfate and chloride). The threshold nitrate concentration at which the nitrite level is expressed as a function only of temperature is 0.02 M.

1992-10-26

446

Revised minimum nitrite concentration for ESP  

Energy Technology Data Exchange (ETDEWEB)

Nitrite is to be used to inhibit pitting corrosion during Extended Sludge Processing (ESP) at the Savannah River Plant. The required nitrite concentrations are expressed as a function of the slurries` nitrate ion concentration and temperature. In the most dilute slurries, the nitrite inhibitor requirement is independent of the nitrate ion concentration and depends only on the temperature of the waste. The nitrate-independent concentration ensures that there is sufficient inhibitor, in sludge slurries whose nitrate has been depleted by radiolysis, to prevent pitting corrosion induced by other corrosive anions (e.g., sulfate and chloride). The threshold nitrate concentration at which the nitrite level is expressed as a function only of temperature is 0.02 M.

1992-10-26

447

Process to eliminate the deposits formed in a steam generator of a pressurized water nuclear reactor  

International Nuclear Information System (INIS)

The present process allows to eliminate the corrosion products formed on the tube plates and in the interstices of plate-tube crosspieces of a PWR steam generator in order to avoid a corrosion phenomenon which may cause denting by presence of oxides. The process consists in applying on these oxides at about 50-100 degrees, an aqueous solution containing 6-8% of gluconic acid, 3-5% of citric acid, about 0.5% of a corrosion inhibitor and ammonia until a pH of 3-9.5 is obtained.

1984-04-05

448

Pitting corrosion of zirconium and hafnium  

Energy Technology Data Exchange (ETDEWEB)

The initiation and inhibition of pitting corrosion on zirconium and hafnium in aqueous solutions have been investigated by potentiodynamic, potentiostatic and galvanostatic measurements at 25/sup 0/C. Effects of Cl/sup -/, Br/sup -/and I/sup -/ have been examined over a range of salt concentrations and pH. All three halide ions cause pitting attack on the two metals, but this may be inhibited by other anions. The results show that hafnium is more easily protected against pitting than is zirconium. The data are treated by the Butler-Volmer equation to yield more information about the mechanisms of the pitting corrosion.

1988-02-01

449

Organometallic Polymer Coatings for Geothermal-Fluid-Sprayed Air-Cooled Condensers: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Researchers are developing polymer-based coating systems to reduce scaling and corrosion of air-cooled condensers that use a geothermal fluid spray for heat transfer augmentation. These coating systems act as barriers to corrosion to protect aluminum fins and steel tubing; they are formulated to resist the strong attachment of scale. Field tests have been done to determine the corrosion and scaling issues related to brine spraying and a promising organometallic polymer has been evaluated in salt spray tests.

2002-08-01

450

Operating experience with condenser tubes made from copper alloys and new developments; Betriebserfahrungen mit Kondensatorrohren aus Kupferlegierungen und aktuelle Entwicklungen  

Energy Technology Data Exchange (ETDEWEB)

Copper alloys are a suitable tubing material for turbine condensers and heat exchangers. Due to problems with corrosions copper alloys increasingly are displaced by high-grade steel and titanium. Blockages and surface formation in the pipes, disturbance of the oxide coating formation, erosion and quality faults with the production are the causes for the corrosion. In the contribution under consideration counter measures are designated for the solution of the problems with corrosions. The application limits for different copper alloys are designated. Recommendations for the optimized operation are given.

2008-07-01

451

Is OD peening of Alloy 800 SG tubes desirable?  

Energy Technology Data Exchange (ETDEWEB)

The shot peening of the outer surface of Alloy 800 is proposed by the steam generator supplier in order to increase the stress corrosion cracking resistance of the tubes. The benefits and drawbacks of such a treatment are evaluated, focusing on the main concern i.e. a possible enhanced tendency of stress corrosion cracking at the transition of the expanded tube-to-tubesheet joint. Stress corrosion tests as well as residual stresses measurements demonstrate no significant difference between peened and unpeened tubes at that location. The other concerns such as stability of the compressive stresses, increased risk of pitting or intergranular attack and pollution of the secondary circuit by fragmented beads appear the as minor concerns.

1992-12-31

452

Effect of pH on the pitting corrosion of austenitic stainless steel in chloride solution  

International Nuclear Information System (INIS)

This paper deals with the pitting corrosion of evaporators in the liquid - radwaste system of nuclear power stations. Corrosion testrs were conducted by the anodic polalization of specimen in the chloride solution. (1) The initiation of the pitting in SUS 304, SUS 316 stainless steels was inhibited by addition of NaOH and H_3BO_3, however, these addition had no effect on the pitting propagation. (2) Inconel 625 had the resitivity against the pitting initiation superior to that of stainless steels, but this was not necessarily in the case of the pitting propagation. (3) It is noticed for pitting prevention that the environmental and material effect on the pitting initiation differed from that on the pitting propagation. (author).

453

Development of ALLOY 800 for PWR/SG tubings resistant to IGSCC and general corrosion  

Energy Technology Data Exchange (ETDEWEB)

Resistance of ALLOY 800 as a PWR/SG tubings to IGC/IGSCC and Ni, Co release into high temperature water was evaluated as compared with ALLOYs 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made. From the results, ALLOY 800 was evaluated to be the most reliable among the high Ni alloys tested. In addition, the alloy would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti and Nb, and the prior oxidation treatments, respectively. (author).

1989-07-01

454

Corrosion resistance of #gamma#-solid solution and hardening #gamma#'-phase of nickel alloys in sodium sulfate and chloride melts  

International Nuclear Information System (INIS)

Corrosion testings of model alloys, corresponding by chemical composition to simple and complex-alloyed #gamma#- and #gamma#'-phases of nickel heat-resistant alloys are conducted in sodium sulfate and chloride melts. It is ascertained that heat resistant nickel alloys containing over 50 % of hardening #gamma#'-phase, are subject to disastrous sulfide corrosion (SC). Resistance against SC alloys containing below 50 % of #gamma#'-phase is determined by the resistance of #gamma#-solid solution. 10 refs., 3 figs., 2 tabs.

455

Corrosion issues in the long term storage of aluminum-clad spent nuclear fuels  

International Nuclear Information System (INIS)

Approximately 8% of the spent nuclear fuel owned by the US Department of Energy is clad with aluminum alloys. The spent fuel must be either reprocessed or temporarily stored in wet or dry storage systems until a decision is made on final disposition in a repository. There are corrosion issues associated with the aluminum cladding regardless of the disposition pathway selected. This paper discusses those issues and provides data and analysis to demonstrate that control of corrosion induced degradation in aluminum clad spent fuels can be achieved through relatively simple engineering practices.

1996-03-24

456

Corrosion cracking of rotor steels of steam turbines  

International Nuclear Information System (INIS)

Results of investigation of stress corrosion cracking of steam turbine materials in nuclear, fossil and geothermal power plants have been analysed. The role of factors that cause damage to rotor discs, mono block and welding rotors of steam turbines has been shown. These are yield stress and steel composition, stress intensity coefficient and crack growth rate, composition and temperature of the condensed steam and water, electrochemical conditions. The conclusion has been made about the state of stress corrosion cracking of the rotors materials, and main investigation trends which are necessary to solve this problem have been listed.

457

A new high nitrogen super austenitic stainless steel with improved structure stability and corrosion resistance properties  

International Nuclear Information System (INIS)

A new highly alloyed (Cr, Mo, W, N) super austenitic grade has been developed. This grade offers high mechanical properties combined with excellent corrosion resistance in chloride acid media. This grade is particularly designed for applications in chloride, oxidizing acid media encountered in the chemical, transportation, pollution control, offshore and pulp and paper industries. Mechanical properties, corrosion resistance and weldability of this grade are presented and compared to that of other stainless steels and nickel base alloys.

1996-03-24

458

Design modifications in radiation monitoring system at Tarapur Atomic Power Station 3 and 4  

International Nuclear Information System (INIS)

Inputs on radiological conditions forms the basis of implementation of effective exposure control to plant personnel in nuclear power station. Radiation monitoring system provides this input to the plant operator as well as to health physics group. Several design modifications have been incorporated in the Radiation Monitoring System at Tarapur Atomic Power Station (TAPS 3 and 4) over the similar systems at Kakrapar Atomic Power Station (KAPS) and Kaiga Generating Station (KGS). The radiological monitoring systems installed at TAPS unit 3 and 4 includes on line Radiation Data Acquisition System (RADAS), Emergency sampling system, effluent monitoring system and environmental monitoring system. The design changes and the versatile use of these systems are presented in this paper. (author)

2006-11-13

459

The influence of aging on the intergranular corrosion of 22 chromium-5 nickel duplex stainless steel  

International Nuclear Information System (INIS)

Duplex stainless steels are widely used in severe corrosion environments because of their good corrosion performance. This paper deals with the influence of aging treatments on the intergranular corrosion (IGC) resistance of a commercial duplex stainless steel, SAF 2205. Duplex stainless steel was given aging treatments in the range 773-1173 K for time periods ranging from 6 min to 100 h. Optical microscopy and XRD was carried out on the aged stainless steels for the microstructural study. The aged samples were evaluated for the IGC susceptibility with the ASTM standard practices. Potentiodynamic cyclic polarization studies were also carried out to investigate the influence of aging treatments on the passivity breakdown. The results indicate that the sigma phase gets precipitated and is responsible for grain boundary attack. (author).

460

The ageing of CANDU steam generator due to localized corrosion  

International Nuclear Information System (INIS)

The Steam Generator (SG) tubing degradation caused by corrosion and other age-related mechanisms continues to be a significant safety and cost concern for many Nuclear Power Plants (NPP). The understanding of the steam generator ageing mechanisms is the key to effective management of steam generator ageing and consists of the knowledge of steam generator materials and these one properties, stressors and operating conditions, like degradation sites and wear mechanisms. The principal types of corrosion are presented which can occur in CANDU steam generator. There are also presented the operation conditions, the specifications referring to the water chemistry and the construction materials of Steam Generator, the factors that have a great influence on the corrosion behaviour during the whole exploitation period of this equipment. (R.P.)

2001-09-17

462

Survey of degradation modes of candidate materials for high-level radioactive-waste disposal containers  

International Nuclear Information System (INIS)

Three copper-based alloys, CDA 102 (oxygen-free, high-purity copper), CDA 613 (aluminum bronze), and CDA 715 (Cu-30Ni), are candidates for the fabrication of high-level radioactive-waste disposal containers. Waste will include spent fuel assemblies from reactors as well as borosilicate glass, and will be sent to the prospective repository site at Yucca Mountain in Nye County, Nevada. The decay of radionuclides will result in the generation of substantial heat and in fluxes of gamma radiation outside the containers. In this environment, container materials might degrade by atmospheric oxidation, general aqueous phase corrosion, localized corrosion (LC), and stress corrosion cracking (SCC). This volume is a critical survey of available data on pitting and crevice corrosion of the copper-based candidates. Pitting and crevice corrosion are two of the most common forms of LC of these ...

1991-07-01

464

Study of the method to improve the corrosion resistance of the matrix materials of spherical fuel elements in HTGR  

International Nuclear Information System (INIS)

Ceramic fuel element is one of the most important items of HTGR technology, and the corrosion resistance of is matrix materials is vital to the operational performance of HTGR. In the paper, based on the oxidation study of the matrix materials, it has been proposed that the corrosion resistance of the matrix materials might be improved through forming carbon -ceramic composite. The experiment results have shown that the corrosion resistance of matrix materials has been improved by addition of SiC superfine powders, and that the matrix materials containing SiC superfine powders and heat-treated at 1600 deg. C had an oxidation rate lower than the general one containing no SiC superfine powder and heat-treated at 1950 deg. C. (author). 5 refs, 8 figs.

1995-01-01

466

Results on incoloy 800 and allied steam generator materials in Florida field corrosion tests  

International Nuclear Information System (INIS)

Appraisals of the isothermal general corrosion of Incoloy 800 in steam at 595 and 650 deg.C indicated good long-term resistance (<7 mg/cm"2 weight gained in 20 years) whether surfaces were ground or electropolished. Electropolished surfaces corroded much faster than ground surfaces in earlier stages, (39 and 15 times as fast in 3000 hr at 595 and 650 deg.C, respectively), but the corrosion rate decreased with time and gave comparable estimates over the long term for both surface preparations. Both nonwelded and welded Incoloy 800 were definately susceptible in chloride stress-corrosion cracking tests of U-bend specimens in a cyclic, wet-dry steam environment. However, C-configuration specimens of Incoloy 800, which were less severly strained, did not crack in this environment. (author).

467

Research on corrosion resistance of steam generator tube  

International Nuclear Information System (INIS)

In order to improve the reliability of PWR steam generators, we have performed research to improve the tubing material and tube-support-plate configuration, based on our wide operating experience, and have developed and verified Alloy TT690 as the optimum tubing material and the BEC (Broached Egg Crate) type tube-support design. In the research, we have studied the metallurgical mechanism of the alloy to improve its corrosion resistance, evaluated corrosion susceptible region quantitatively, estimated the actual environment in a steam generator and confirmed the reliability by a model boiler test over a long period. It has been verified that the steam generator with the latest design has higher reliability with respect to the corrosion resistance of tubes. (author).

469

Laser surface modification for aqueous corrosion resistance  

International Nuclear Information System (INIS)

Laser surface modification can lead to formation of a novel microstructure on the surface of a material resulting in improved surface properties. During the past one and half decades, a number of investigations have been reported on laser surface modification techniques for improving the corrosion resistance of various materials. This paper reviews various work reported on utilising laser modification techniques for enhancing the aqueous corrosion resistance of materials. The laser surface modification work carried out on materials like stainless steels, C-steels, low alloy steels and non-ferrous materials such as Zr, Zn, Al, Ni, Mg and their alloys has been covered in the review. General features observed in improving the corrosion resistance after laser processing have been discussed and scope for future investigations in this field has been highlighted. (author). 97 refs., 15 figs., 5 tabs.

470

Investigation on corrosion resistance of amorphous films prepared by ion beam mixing  

International Nuclear Information System (INIS)

Fe-Cr amorphous films have been formed by both in situ evaporation of multilayered films and ion beam mixing in a target chamber of a 200 keV implanter. The effects of Cr content and ion irradiation on the amorphization of films were examined by transmission electron microscope (TEM). Corrosion of film was investigated by means of a potential dynamic polarization. Corrosion resistance of amorphous film in 0.5 mol H-2SO-4 solution is considerably increased than that of pure iron. Using X ray photoelectron spectroscopy (XPS) corrosion resistance in atmosphere of amorphous Fe-Cr passive films formed by P"+ mixing was studied. Results show that the richness of Cr and P exist at the surface of Fe-Cr film.

1991-01-01

471

Initiation process of type 1 pitting corrosion on copper water-tubes; Reisui yo dokan ni okeru 1 gata koshoku no hassei  

Energy Technology Data Exchange (ETDEWEB)

Copper tubes have been widely used for water supply and heat exchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heat exchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA (Electron Probe ...

1999-07-15

472

Influence of carbon and nitrogen on corrosion resistance of high purity Fe-50mass% Cr alloys  

International Nuclear Information System (INIS)

High purity Fe-50mass%Cr alloys containing (C+N) in the range of 30 to 500 mass ppm were prepared and their corrosion resistance was investigated. Pitting potential in a 3.5mass%NaCl solution at 343K rose with reducing (C+N) content. Alloys containing (C+N) at less than 100 mass ppm did not sustain pitting corrosion. However, alloys containing 500 mass ppm (C+N) corroded severely in 6%FeCl_3+1/20N HCl solutions. Heat treatment at 923K was recognized as influencing corrosion resistance due to precipitation of carbonitrides only in the case of the alloy containing 500 mass ppm (C+N). (orig.).

475

IGC/IGSCC and general corrosion behavior of alloy 800 as a PWR S/G tube material  

Energy Technology Data Exchange (ETDEWEB)

Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.

1987-01-01

476

IGC/IGSCC and general corrosion behavior of alloy 800 as a PWR S/G tube material  

International Nuclear Information System (INIS)

Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.

1987-03-09

477

Hard Corrosion and Radiation-Resistant Coatings  

International Science & Technology Center (ISTC)

Hard Nano-Strutural Coatings Resistant to the Extreme Conditions of Chemical, Abrasive and High Energy Media for Thermonuclear Power, Oil and Gas and Chemical Industries

479

Evaluation, testing and database generation of pitting corrosion characteristics of domestic steam generator tubing material  

Energy Technology Data Exchange (ETDEWEB)

Accumulation of Chloride and Cupric ions under the sludge on the steam generator tubing surface in the area between tube sheet and the first tube support is known to be the main reason for the pitting corrosion. In addition to those ions, oxygen, pH, temperature, heat treatment history, contests of minor elements such as C, S or Ti in the alloy are also influencing the material's the pitting corrosion resistance. a series of autoclave pitting test was conducted to evaluate the pitting corrosion characteristics of the domestically produced alloy 690 tubing material and compare with that of INCO manufactured material. 16 refs., 44 figs., 5 tabs. (Author)

1998-04-01

480

Enhanced corrosion resistance properties of radiofrequency cold plasma nitrided carbon steel: Gravimetric and electrochemical results  

Energy Technology Data Exchange (ETDEWEB)

Cold plasma nitriding treatment was performed to improve the corrosion resistance of C38 carbon steel. Nitriding process was conducted using a radiofrequency nitrogen plasma discharge for different times of treatment on non-heated substrates. The modification of the corrosion resistance characteristic of the C38 steel due to the treatment in acid medium (1 M HCl) were investigated by gravimetric and electrochemical tests such as potentiodynamic polarisation curves and electrochemical impedance spectroscopy (EIS). It was shown that the plasma nitriding treatment improves the corrosion resistance. Indeed, in the gravimetric tests, nitrided samples showed lower weight loss and lower corrosion rate in comparison to untreated one. In the Tafel polarisation tests, the nitrided samples showed greatly reduced corrosion current densities, anodic dissolution and also retarded the hydrogen ...

2009-03-01

485

Corrosion resistance of alloy steels in hot solutions of orthophosphoric acid  

International Nuclear Information System (INIS)

The rate of corrosion of alloyed steels in solutions of orthophosphoric acid at the temperatures from 100 to 200 deg C has been ascertained by gravimetric method. It is shown that the 06Kh23N28MDT steel features the highest corrosion resistance, the second in terms of the characteristic mentioned is 08Kh22N6T, then - 10Kh17N13M2T, 08Kh21N6M2T, 12Kh18N9T. Corrosion rate of the steels studied intensifies at the acid concentrations exceeding 10% and increases essentially with the temperature increase. 6 ref., 2 tabs.

486
487

Chromium-Manganese Nonmagnetic Steels  

International Science & Technology Center (ISTC)

Corrosion- and Wear Resistant Silicon Containing Chromium-Manganese and Nickel-Chromium-Manganese Nonmagnetic Steels with Increased Strength and Toughness for Reliable Work at Normal and Cryogenic Temperatures

488

CERL code capabilities for modeling AVT chemistry  

International Nuclear Information System (INIS)

The CERL Code was developed to describe the solution chemistry of the water on the steam generating side of PWR reactors. It is designed to calculate the equilibrium species distribution resulting from the interaction of impurities, corrosion products, and additives in the aqueous solution. It calculates the extent of ion-ion interactions, the precipitation of insoluble species and the amount of solute that partitions into the vapor phase when some of the water evaporates. This knowledge of the bulk phase equilibrium distribution of species, especially the pH should be useful in describing the corrosion processes at the solid liquid boundary. The code does not calculate any changes in oxidation states or any rates of reaction. Therefore, it is incapable of calculating the actual corrosion rates. It is anticipated that it will be used as a subprogram of a larger program that will include the redox reactions and the rates of ...

1985-03-01

489

An investigation on the effect of bleaching environment on pitting corrosion and trans-passive dissolution of 316 stainless steel  

Energy Technology Data Exchange (ETDEWEB)

Pitting corrosion and trans-passive dissolution of 316 stainless steel in solution containing five percent of commercial bleaching liquid was investigated by employing potentiodynamic polarization method and recording corrosion potential during immersion. Today commercial bleaching liquids are widely used as cleaner additives, therefore, those house appliances made from stainless steels are in contact with aqueous solution containing bleaching liquid. This may cause sever localized corrosion and trans-passive dissolution. In order to investigate the possibility of trans-passive dissolution of stainless steel by bleaching liquid, potentiodynamic polarization and recording variation of corrosion potential of specimens were carried out in 0.2 M Na{sub 2}SO{sub 4} solution containing 5 %wt. commercial bleaching liquid. A 500 mV drop in trans-passive potential and also instantaneously ennobling ...

2004-07-01

490

Amorphization of Zr_6_0Al_1_5Ni_2_5 surface layers by laser processing for corrosion resistance  

International Nuclear Information System (INIS)

It is generally known that a number of metallic glasses have excellent corrosion resistance in a variety of chemically hostile environments. Consequently, the use of laser cladding to coat a massive crystalline material such as aluminium with a layer of a metallic glass has obvious advantages. In this paper, the authors will show that the formation of a predominantly amorphous layer of Zr_6_0Al_1_5NI_2_5 alloy by laser processing is possible, if the obstacles to amorphization are overcome. In addition, evidence of the excellent corrosion resistance of this alloy in a NaCl solution will be given. A comparative study of the corrosion behavior of this amorphous alloy with pure aluminium and Al-Cr alloy will be done, in order to complete previous studies of laser processed coatings of aluminum substrates.

491

Acid Waste Equipment on Environmental Expert  

Wastenet

...Systems by IPEX Enfield electrofusion acid waste systems give you the proven corrosion resistance of polypropylene, along with our patented, state-of-the-art electrofusion system....

493

A new technique for surface modification in magnesium alloys by applying magnesium oxide coating  

Energy Technology Data Exchange (ETDEWEB)

A new technique was proposed in order to improve poor corrosion resistance in magnesium. That is, magnesium hydroxide film was formed on the surface of 3 N-Mg by artificial corrosion in 1% MgCl{sub 2} solution for 3.6 ks, which followed by oxidation at 673 K for 3.6 ks in air. Corrosion resistance was evaluated by salt immersion tests in 1% NaCl solution under in situ laser microscopic observations. Bubble evolution, which occurred immediately at the beginning of the immersion test in the case of non-treated specimen, was suppressed by the process. And also, formation of filiform corrosion was suppressed for about 3.6 ks, which occurred at 180 s in the non-treated specimen. (orig.)

2003-07-01

494

A laboratory and field investigation of naphthenic acid corrosion inhibition  

Energy Technology Data Exchange (ETDEWEB)

This paper presents results of a laboratory and field study of naphthenic acid corrosion and the development of an effective chemical inhibitor for this type of corrosive attack. In the laboratory corrosion test, which involved 20 hour weight loss measurements in high flash solvent with a total acid number (TAN) of 16 mg KOH/gm at a temperature of 600 F (316 C), blank corrosion rates averaged 140 to 150 mpy (3.56 to 3.81 mm/y). Inhibited rates averaged about 10 to 12 mpy (0.254 to 0.305 mm/y). The field test was carried out on a heavy vacuum gas oil (HVGO) stream at 550 F (288 C) . Blanks varied from a high of 425 mpy (10.79 mm/y) for a 24 hour test to a low of about 100 mpy (2.54 mm/y) for a 150 hour test. Both electrical resistance (ER) probes and weight loss coupons showed corrosion rates below 5 mpy (0.127 mm/y) as long as they were adequately passivated. Passivation consisted ...

1995-11-01

495

Wildlife Monitoring Program Plan - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Wildlife Monitoring System Schematic .......................... 40 ...... sentinel species - healthy fish are placed in an environment of water (where they arc not .... The way ir! which data for the fnre mdor study groups will be gathered tor managciacilt ...... Earth Resources Aircraft Program (ERAP) Camera ...

496

Overall control and monitoring systems for pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

The article describes control and monitoring concepts in which the delegation of responsibility is becoming more decisive than ever (automation hierarchy), and which are capable of optimized, automatic control of process events in pumped storage plants. 8 refs.

1982-06-01

497

Innovative coke oven gas cleaning system for retrofit applications  

Energy Technology Data Exchange (ETDEWEB)

The EMP consists of a Compliance Monitoring Sampling Program and a Supplemental monitoring Sampling Program. The Compliance Monitoring Sampling Program will be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Project and during a summer and a winter period following the successful Startup and Operational phase of the completed Project. compliance monitoring consist of conducting all the sampling and observation programs associated with existing required Federal, State, and Local Regulations, Permits and Orders. These include air, water, and waste monitoring and OSHA and NESHAP monitoring. The Supplemental Monitoring Program will also be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Demonstration Facility and during a ...

1992-09-21

498

A randomised clinical trial of intrapartum fetal monitoring with computer analysis and alerts versus previously available monitoring  

UK PubMed Central (United Kingdom)