Does Water Deficit Stress Promote Ethylene Synthesis by Intact Plants? 1
UK PubMed Central (United Kingdom)
The effect of plant water deficit on ethylene production by intact plants was tested in three species, beans (Phaseolus vulgaris L.), cotton (Gossypium hirsutum L.)...Full Text Available
1990-12-01
International Nuclear Information System (INIS)
Requirements for the installation, inspection, and testing that assure the quality of important components of a nuclear power plant during construction are presented.
International Nuclear Information System (INIS)
This standard provides requirements and guidelines for installation, inspection and testing activities that assure the quality of important mechanical parts of a nuclear power plant not covered by the ASME Boiler and Pressure Vessel Code, Section III, during construction. These parts include those mechanical systems and components whose satisfactory performance is required: for the plant to operate reliably; to prevent accidents that could cause undue risk to the health and safety of the public; or to mitigate the consequences of such accidents if they were to occur. The requirements of this standard deal with the protection and control necessary to assure that the requisite quality of those important parts of the plant are preserved from the time items are removed from storage or receiving until they are incorporated into the plant up to but not including fuel loading for PWR ...
Status of FFTF startup program and future FFTF utilization
International Nuclear Information System (INIS)
A brief FFTF project description is provided which includes general plant siting information, general layout, plant design parameters, description of principal systems and components, and description of support facilities. The current status of the FFTF project is provided, including status of plant construction, overall status of the plant checkout and test program, status of operating authorization and plant operating procedures and personnel, and status of reactor core components and experiments. Specific information on the acceptance test program and early program results is discussed. The role of FFTF in the future breeder program is described, including its objectives for verification of plant system and components designs and operability and use as an irradiation test facility.
1978-10-25
Natural convection cooling studies and tests performed for the CREYS MALVILLE plant
International Nuclear Information System (INIS)
For the CREYS MALVILLE plant, sodium natural convection has been considered in connection with certain upset, faulted or beyond design basis situations. For each of these cases, this paper will discuss why natural convection was considered, the main conclusions reached and the natural convection tests which will be performed at plant start-up.
Energy Technology Data Exchange (ETDEWEB)
Cooling waters from eleven geographically disparate power plants were tested for the presence of Naegleria fowleri and Legionella pneumophila (LDB). Control source waters for each plant were also tested for these pathogens. Water from two of the eleven plants contained pathogenic Naegleria, and infectious Legionella were found in seven of the test sites. Pathogenic Naegleria were not found in control waters, but infectious Legionella were found in five of the eleven control source water sites. Concentrations of nitrite, sulfate, and total organic carbon correlated with the concentrations of LDB. A new species of Legionella was isolated from one of the test sites. In laboratory tests, both Acanthamoeba and Naegleria were capable of supporting the growth of Legionella pneumophila.
1982-10-01
PWR primary circuit piping installation of Daya Bay Nuclear Power Plant
International Nuclear Information System (INIS)
The installation procedure, the fabrication, fitting up, positioning, adjustment and welding of piping, examinations, hydrostatics testing and insulation of piping for reactor primary circuit piping of Daya Bay Nuclear power Plant are briefly described.
General requirements for concrete containment structures for CANDU nuclear power plants
International Nuclear Information System (INIS)
This standard provides the general requirements used in the design, construction, testing, and commissioning of concrete containment structures for CANDU nuclear power plants designated as class containment and is directed to the owners, designers, manufacturers, fabricators, and constructors of the concrete components and parts.
2006-02-01
FFTF operating experience, 1982-1984
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400 Mwt sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory, Richland, Washington, to conduct fuels and materials testing in support of the US Liquid Metal Fast Breeder Reactor (LMFBR) program. Startup and initial power testing included a comprehensive series of nonnuclear and nuclear tests to verify the thermal, hydraulic, and neutronic characteristics of the plant. A specially designed series of natural circulation tests were then performed to demonstrate the inherent safety features of the plant. Early in 1982, the FFTF began its first 100-day irradiation cycle. Since that time the plant has operated very well, achieving a cycle capacity factor of 94% in the most recent irradiation cycle. Seventy-five specific test ...
1984-04-09
Nuclear power plant liquid waste solidification system. [Japan
Energy Technology Data Exchange (ETDEWEB)
The fundamental points to be considered in a waste treatment system for a country like Japan, where the final disposal method has not been decided and the wastes have to be stored in the power plants, are volume reduction of the wastes, safe storage of the wastes in the plant, and flexibility regarding the final disposal. A system has been developed that consists of a thin film evaporator for the direct solidification of the liquid waste, a pelletizer for producing hard pellets from the powdered wastes, a pellet storage unit, and a solidification unit for the final disposal. A pilot plant with waste treatment capacity of 200 kg/h was built in 1976 and has proved the system feasibility. This paper reports on pilot plant tests of the thin film evaporator and other components, tests on pellet deterioration during long term storage, and integrity ...
1981-01-01
Nuclear power plant liquid waste solidification system
International Nuclear Information System (INIS)
The fundamental points to be considered in a waste treatment system for a country like Japan, where the final disposal method has not been decided and the wastes have to be stored in the power plants, are volume reduction of the wastes, safe storage of the wastes in the plant, and flexibility regarding the final disposal. A system has been developed that consists of a thin film evaporator for the direct solidification of the liquid waste, a pelletizer for producing hard pellets from the powdered wastes, a pellet storage unit, and a solidification unit for the final disposal. A pilot plant with waste treatment capacity of 200 kg/h was built in 1976 and has proved the system feasibility. This paper reports on pilot plant tests of the thin film evaporator and other components, tests on pellet deterioration during long term storage, and integrity ...
1981-02-26
International Nuclear Information System (INIS)
1974. 20 p. United States Anon. American Society of Mechanical
International Nuclear Information System (INIS)
1973. 27 p. United States Anon. American Society of Mechanical
International Nuclear Information System (INIS)
The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.
International Nuclear Information System (INIS)
(Nov 1973). United States Basile, G. US Testing Co., Inc., Hoboken,
1973-11-11
Acceptance test of full scope simulator of Daya Bay NPP
International Nuclear Information System (INIS)
The author describes the purpose, classification and main process of acceptance test of full scope simulator of Daya Bay Nuclear Power Plant, including the correction of non-conformance items which are discovered during the performance of acceptance tests. The results of the acceptance tests show that the model accepted by the full scope simulator of Daya Bay Nuclear Power Plant is fully able to cope with the simulation of normal transients and incidental transients and the performance of the simulator indeed compiled with the technical specifications which are defined n the relevant contracts.
W-026 acceptance test plan plant control system hardware (submittal {number_sign} 216)
Energy Technology Data Exchange (ETDEWEB)
Acceptance Testing of the WRAP 1 Plant Control System Hardware will be conducted throughout the construction of WRAP I with the final testing on the Process Area hardware being completed in November 1996. The hardware tests will be broken out by the following functional areas; Local Control Units, Operator Control Stations in the WRAP Control Room, DMS Server, PCS Server, Operator Interface Units, printers, DNS terminals, WRAP Local Area Network/Communications, and bar code equipment. This document will contain completed copies of each of the hardware tests along with the applicable test logs and completed test exception reports.
1997-02-14
Alternative cycles based on carbon dioxide for central receiver solar power plants
British Library Electronic Table of Contents (United Kingdom)
Research in concentrated thermal solar power plants of all types and, in particular, those based on central receiver, namely solar tower plants, has experienced great impetus in the last decade, reaching full commercial operation with the PS10 plant in Spain. In spite of previous demonstration plants testing different receivers and power cycle layouts, this first commercial power plant adopted a cavity receiver generating saturated steam and therefore penalising cycle efficiency in order to gain plant reliability. According to the experience gained, if a competitive Levelised Cost of Electricity is to be reached, capital and maintenance costs must be reduced and efficiencies must be increased. To achieve these goals, modifying the power cycle is deemed essential, whether using superheated ...
2011-01-01
Effectively use corrosion testing
Energy Technology Data Exchange (ETDEWEB)
The proper selection of materials of construction is necessary to provide process equipment with optimum performance and corrosion resistance. If properly chosen, the selected material should deteriorate at a uniform, predictable rate, which will allow for maintenance or replacement at scheduled intervals. This concept of risk assessment for predictive maintenance is a minimum requirement for proper materials selection. Materials selection is based on prior service history, field corrosion tests, pilot-plant tests, and laboratory bench-top tests--in that relative order of usefulness. Corrosion test methods are usually divided into two groups: laboratory and field (plant-site) tests. The main difference between the two is that field test specimens are exposed to actual process conditions will all of the variables ...
1995-04-01
Model tests on a semi-axial pump turbine
Energy Technology Data Exchange (ETDEWEB)
Due to their good hydraulic characteristic semi-axial pump turbines are used in the medium head range of pumped storage plants. This paper describes model tests performed on a semiaxial pump turbine model and shows the results of these tests. The aim of the model tests was the optimization of the hydraulic water passage, the measurement of the hydraulic characteristics over the whole operating range, the investigation of the cavitation behaviour, the investigation of the hydraulic forces and torques as well as the proof of the values guaranteed to the customer.
1984-03-01
Accelerated aging speeds test of instrument reliability
International Nuclear Information System (INIS)
Safety-related instrument in nuclear power plants must be checked for reliability over their projected operating life. A method of conducting accelerated aging tests is presentd. It uses the Arrhenius activation energy concept and manipulation of the parameters of the test e.g. by raising test temperature, by relying on a model characterizing the chemical-related reactions of materials.
1982-01-01
Actinide chemistry: From test tube to billion dollar plant-A BNFL perspective
British Nuclear Fuels (BNFL) is currently operating its third generation of nuclear plant for the management of irradiated nuclear fuel. Development for the fourth generation plant must meet requirements for processing higher burn-up fuel with lower unit costs, lower environmental impact, better process control, and more flexible control of actinides. .
2000-07-01
Applicability of structural wall test results to seismic design of nuclear facilities
International Nuclear Information System (INIS)
A review of tests on earthquake-resistant reinforced concrete structural walls is presented. Laboratory tests of isolated walls and construction joints are discussed. Where appropriate, design recommendations are given. The review indicates only few experimental data are available for short walls which are directly applicable to nuclear power plant design. In particular, tests of short rectangular walls subjected to load reversals are needed. Tests are also needed to determine the damping and frequency characteristics of cracked short walls. Analytical and experimental results should be correlated so that the hysteretic response observed in tests can be realistically related to the analytical response 'demand' of nuclear power plant structures. (Auth.).
Regeneration of zinc anodes for the Electric Fuel{reg_sign} zinc-air refuelable EV battery system
Energy Technology Data Exchange (ETDEWEB)
The Electric Fuel Limited (EFL) refuelable zinc-air battery system is currently being tested in a number of electric vehicle demonstration projects, the largest of which is a field test of zinc-air postal vans sponsored chiefly by Deutsche Post AG (the German Post Office). The zinc-air battery is not recharged electrically, but rather is refueled through a series of mechanical and electrochemical steps that will require a special infrastructure in commercial application. As part of the German Post Office field test program, Electric Fuel designed and constructed a pilot zinc anode regeneration plant in Bremen, Germany. This plant is capable of servicing up to 100 commercial vans per week, which is adequate for the field test vehicle fleet. This paper will describe the design and operation of each of the areas and devices within the plant.
1997-12-31
Fingerprint testing of contaminated ventilation extract filter systems at Sizewell B
International Nuclear Information System (INIS)
Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' ...
Development of Reliability Data Management System (RDMS) for safety systems of PHWR type plants
International Nuclear Information System (INIS)
The Reliability Data Management System (RDMS) for safety systems of PHWR type plants has been developed and utilized in the reliability analysis of the special safety systems of Wolsong Unit 1 with plant overhaul period lengthened. The RDMS is developed for the periodic efficient reliability analysis of the safety systems of Wolsong Unit 1. In addition, this system provides the function of analyzing the effects on safety system unavailability if the test period of a test procedure changes as well as the function of optimizing the test periods of safety-related test procedures. The RDMS can be utilized in handling the requests of the regulatory institute actively with regard to the reliability validation of safety systems.
1999-10-01
Comparison of toxicity to terrestrial plants with algal growth inhibition by herbicides
Energy Technology Data Exchange (ETDEWEB)
The toxicities of 21 different herbicides to algae (Selenastrum capricornutum and Chlorella vulgaris) and to terrestrial plants (radishes, barley, and bush beans or soybeans) were compared to order to determine the feasibility of using a short-term (96-h) algal growth inhibition test for identifying chemicals having potential toxicity in a 4-week terrestrial plant bioassay. The toxicity of each test chemical, usually in combination with a commercial formulation, was evaluated at six nominal concentrations, between 0 and 100 mg/L growth medium in the algal bioassay or between 0 and 100 mg/kg substate in the terrestrial plant bioassay, in terms of both (1) the no-observed-effect concentration (NOEC), i.e., the highest concentration tested at which no significant (P < 0.05, one-sided test) reduction in algal growth rate or in terrestrial ...
1984-10-01
Energy Technology Data Exchange (ETDEWEB)
A two-year demonstration run of a 500 C/100kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy pilot plant has been started from February 1998; this plant represents as the final stage of the NEDO project of development of a high-efficiency waste-to-energy plant. Alloy 625 (SB444) and 310 HCbN tubings were selected for the 3rd and 2nd superheater of the pilot plant, respectively, and ten kinds of conventional and new solid-wall tubings, weld overlayed tubings, composite tubings, and cermet spray coated tubings were tested. By means of 6000-hour field corrosion test in three typical domestic plants, material life and corrosion environment for superheater tubings installed in the pilot plant were evaluated. Also, the effect of alloying elements Cr, Ni, Mo, corrosion rate law, etc. were investigated in detail. ...
1999-11-01
Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test
Energy Technology Data Exchange (ETDEWEB)
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the ...
2008-10-15
Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test
International Nuclear Information System (INIS)
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the ...
2008-10-01
Engineering Development of Coal-Fired High-Performance Power Systems
Energy Technology Data Exchange (ETDEWEB)
A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolysis process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is generated and gas turbine ...
2000-12-31
Performance Testing Methodology for Safety-Critical Programmable Logic Controller
International Nuclear Information System (INIS)
The Programmable Logic Controller (PLC) for use in Nuclear Power Plant safety-related applications is being developed and tested first time in Korea. This safety-related PLC is being developed with requirements of regulatory guideline and industry standards for safety system. To test that the quality of the developed PLC is sufficient to be used in safety critical system, document review and various product testings were performed over the development documents for S/W, H/W, and V/V. This paper provides the performance testing methodology and its effectiveness for PLC platform conducted by KOPEC
2009-05-01
Intermediate scale borehole (Room C): In situ data report (January 1989--June 1993)
Energy Technology Data Exchange (ETDEWEB)
Data are presented from the intermediate scale borehole test, an in situ test fielded in the pillar separating Rooms C1 and C2 at the Waste Isolation Pilot Plant (WIPP). The test was to provide data on the influence of scale, if any, on the structural behavior of underground openings in salt. These data include selected fielding information, test configuration, instrumentation activities, and comprehensive results from a large number of gages. Construction of the test began in December 1989, with the drilling of the intermediate scale borehole in December 1990. Gage data in this report cover the period from January 1989 through June 1993.
1994-11-01
Energy Technology Data Exchange (ETDEWEB)
This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)
1998-12-15
Experimental and analytical studies of pipe whip tests under PWR LOCA conditions
Energy Technology Data Exchange (ETDEWEB)
A series of pipe rupture tests has been performed at JAERI to demonstrate the safety of primary coolant circuits in the event of pipe rupture in nuclear power plants. Pipe whip tests and jet discharge tests have been conducted under BWR and PWR loss-of-coolant accident (LOCA) conditions. The present paper describes the experimental and analytical results of the pipe whip tests performed under PWR LOCA conditions using 4, 6 and 8-inch test pipes. The tests were carried out at an initial pressure and temperature of 15.7 MPa and 325/sup 0/C, respectively. Moreover, a dynamic analysis of pipe whip tests was carried out using the general purpose finite element programm ADINA.
1987-09-01
Plastic wastes as support fuel. Jaetemuovin kaeyttoe tukipolttoaineena
Energy Technology Data Exchange (ETDEWEB)
The association of Finnish Plastics Industry examined the possibilities to utilize energy content of plastic wastes in spring 1990. A bark fuelled boiler plant of forest industry was used as test power plant. The power of the plant was 60 Mw. This report discusses shortly the theory of combustion of plastics. About 130 000-15 000 tons of plastic waste, corresponding to 7 % of the solid municipal waste, is dumped annually in Finland. Utilization of the plastic waste recovered from municipal wastes for energy production is technically viable in present power plants among present energy production. The chipping and mixing of the plastic in the other fuel are the only pretreatment required for the plastic waste. In Finland there are several power plants using suitable fuels for plastic mixture combustion. The portion of the plastic of the total fuel power was 10 %. ...
1991-01-01
Overview of reliability test program on primary coolant piping of light water reactors
Energy Technology Data Exchange (ETDEWEB)
Upon request by the Science and Technology Agency of Japanese Government, the Japan Atomic Energy Research Institute has conducted Piping Reliability Test Program to demonstrate the safety and reliability of light water reactor primary pipings. In this report, the results of the program are summarized. In the test program, pipe fatigue tests, Leak-Before-Break (LBB) verification tests and pipe rupture tests were carried out to examine the integrity of pipings, to verify the LBB concept and to demonstrate the effectiveness of the protective measures against jet impingement and pipe whip under pipe rupture event, respectively. In the pipe fatigue tests, a procedure to predict the fatigue crack growth was developed and the integrity of piping during plant service life was demonstrated. In the LBB verification tests, pipe ...
1993-10-01
Establishment of Database Program for In-service Test Management in Nuclear Power Plants
International Nuclear Information System (INIS)
In-service Test (IST) of the nuclear power plant is very important to maintain the safety of the plants. The safety features of nuclear power plant are based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves. Because of the importance of the IST, most of nuclear power plants should designate the IST department and personnel. Because the nuclear power plants of Korea have several types and the designs and operations are different from each other, the methods and experiences are various for the management of the IST program. However, there are no medium to communicate with each other and exchange the tips and information about IST program and education and discussion would be required to apply a consistent code. The nature of the IST ...
2010-10-01
Desulphurization of hot reducing gases in the entrained bed reactor
Energy Technology Data Exchange (ETDEWEB)
Using an experimental pilot plant, designed and built for the tests, the influence of the following parameters was determined: desulphurization of the test gas, temperature, residence time in the reactor tube, concentration of the hydrogen sulphide and desulphurization agent, size of the particles which comprise the agent and composition of the gas. Allowance was made for the effect of calcination and carbonisation. Desulphurization was carried out with limestone on a gaseous mixture of CO and H/sub 2/. A mathematical description of the test findings and yield is presented. 8 refs.
1986-08-01
Posttest analysis of the FFTF inherent safety tests
Energy Technology Data Exchange (ETDEWEB)
Inherent safety tests were performed during 1986 in the 400-MW (thermal) Fast Flux Test Facility (FFTF) reactor to demonstrate the effectiveness of an inherent shutdown device called the gas expansion module (GEM). The GEM device provided a strong negative reactivity feedback during loss-of-flow conditions by increasing the neutron leakage as a result of an expanding gas bubble. The best-estimate pretest calculations for these tests were performed using the IANUS plant analysis code (Westinghouse Electric Corporation proprietary code) and the MELT/SIEX3 core analysis code. These two codes were also used to perform the required operational safety analyses for the FFTF reactor and plant. Although it was intended to also use the SASSYS systems (core and plant) analysis code, the calibration of the SASSYS code for FFTF core and plant analysis ...
1987-01-01
Posttest analysis of the FFTF inherent safety tests
International Nuclear Information System (INIS)
Inherent safety tests were performed during 1986 in the 400-MW (thermal) Fast Flux Test Facility (FFTF) reactor to demonstrate the effectiveness of an inherent shutdown device called the gas expansion module (GEM). The GEM device provided a strong negative reactivity feedback during loss-of-flow conditions by increasing the neutron leakage as a result of an expanding gas bubble. The best-estimate pretest calculations for these tests were performed using the IANUS plant analysis code (Westinghouse Electric Corporation proprietary code) and the MELT/SIEX3 core analysis code. These two codes were also used to perform the required operational safety analyses for the FFTF reactor and plant. Although it was intended to also use the SASSYS systems (core and plant) analysis code, the calibration of the SASSYS code for FFTF core and plant analysis ...
1987-06-07
British Library Electronic Table of Contents (United Kingdom)
The methanol and aqueous extracts of 10 plant species (Acacia nilotica, Azadirachta indica, Carissa edulis, Fagaropsis angolensis, Harrissonia abyssinica, Myrica salicifolia, Neoboutonia macrocalyx, Strychnos heningsii, Withania somnifera and Zanthoxylum usambarensis) used to treat malaria in Meru and Kilifi Districts, Kenya, were tested for brine shrimp lethality and in vitro anti-plasmodial activity against chloroquine-sensitive and chloroquine-resistant strains of Plasmodium falciparum (NF54 and ENT30). Of the plants tested, 40% of the methanol extracts were toxic to the brine shrimp (LD5050N. macrocalyx had the highest toxicity to brine shrimp nauplii (LD50 21.04+-1.8mg/ml). Methanol extracts of the rest of the plants exhibited mild or no brine shrimp toxicity (LD50>50mg/ml). The aqueo...
2006-01-01
VIPEX (Vital-area Identification Package EXpert) Software Verification and Validation
International Nuclear Information System (INIS)
The purposes of this report are (1) to perform a Verification and Validation (V and V) test for the VIPEX(Vital-area Identification Package EXpert) software and (2) to improve a software quality through the V and V test. The VIPEX was developed in Korea Atomic Energy Research Institute (KAERI) for the Vital Area Identification (VAI) of nuclear power plants. The version of the VIPEX which was distributed is 3.2.0.0. The VIPEX was revised based on the first V and V test and the second V and V test was performed. We have performed the following tasks for the V and V test on Windows XP and VISTA operating systems: ? Testing basic functions including fault tree editing ? Testing all kind of functions ? Research for update from Visual BASIC 6.0 to Visual BASIC 2008
2003-12-01
A vibration amplification device for the seismic margins test of NPP equipment
International Nuclear Information System (INIS)
This paper describes new test methodologies to obtain data used to evaluate the ultimate seismic strength of Nuclear Power Plant (NPP) equipment related to nuclear safety. The paper first reviews existing equipment seismic test data from the viewpoint of the evaluation of their ultimate seismic strength and/or seismic design margins, and extracts the issues in the existing data with regard to their applicability to the evaluation. Then, the paper proposes new test methodologies for the equipment to evaluate their ultimate seismic strength. The test methodology of the equipment employs a vibration amplification system to a shaking table and enhances its applicable maximum acceleration up to 6g. The test methodology herein is cost effective for obtaining test data that is indispensable for evaluating proper seismic margins of NPPs. (author)
2003-09-15
Host plant odor extracts with strong effects on oviposition behavior in Papilio polyxenes
British Library Electronic Table of Contents (United Kingdom)
Abstract Ovipositing females of the black swallowtail butterfly, Papilio polyxenes Fabricius (Lepidoptera: Papilionidae: Papilioninae), have an innate response to contact chemical cues, but it was not known how naive females would respond to volatile host plant chemicals. Naive and experienced females were tested in a free-flight experiment using model plants and volatile extracts from two hosts, carrot [Daucus carota L. (Apiaceae)] and poison hemlock [Conium maculatum L. (Apiaceae)], and one non-host, fava bean [Vicia faba L. (Fabaceae)]. Naive females responded to both host plant extracts with more approaches and landings than to non-host extracts, with poison hemlock receiving more responses than carrot. Females experienced with one of the two host plants also approached and landed freq...
2008-01-01
International Nuclear Information System (INIS)
Two inactive tracer techniques for determination of the decontamination factor (DF) of evaporation plants for radioactive waste water are described. One method was used for determination of the DF of an one stage pilot plant. The elements Mg, Cd and Co were employed as tracers. The analyses were performed by atomic absorption spectroscopy. The measurements being fast and simple are especially advantageous with test series in pilot plants. In the second method activation analysis was used for measurement of the tracer to determine the DF of a two stage evaporation plant. Europium is added to the stock solution in a concentration of 70 ppm only. With this method a DF of up to 3 . 10"8 can still be determined. (Auth.).
Energy Technology Data Exchange (ETDEWEB)
The thermal-hydraulic tests for a horizontal steam generator of a next-generation PWR (New PWR-21) were performed. The purpose of these tests is to understand the thermal-hydraulic behavior in the secondary side of horizontal steam generator during the plant normal operation. A test was carried out with cross section slice model simulated the straight tube region. In this paper, the results of the test is reported, and the effect of the horizontal steam generator internals on the thermal-hydraulic behavior of the secondary side and the circulation characteristics of the secondary side are discussed. (author)
1996-12-31
International Nuclear Information System (INIS)
The thermal-hydraulic tests for a horizontal steam generator of a next-generation PWR (New PWR-21) were performed. The purpose of these tests is to understand the thermal-hydraulic behavior in the secondary side of horizontal steam generator during the plant normal operation. A test was carried out with cross section slice model simulated the straight tube region. In this paper, the results of the test is reported, and the effect of the horizontal steam generator internals on the thermal-hydraulic behavior of the secondary side and the circulation characteristics of the secondary side are discussed. (author).
1996-10-15
UK PubMed Central (United Kingdom)
Three flocks raised for broiler or roaster performance tests were studied to determine the incidence and sources of salmonellae during the growing period, transport and processing and to relate these...Full Text Available
1982-07-01
International Nuclear Information System (INIS)
1973. 27 p. United States American Society of Mechanical Engineers.;
FFTF reactor assembly system technology
An overview is presented of the FFTF reactor and plant together with descriptions of core components, core internals, core system, primary and secondary control rod system, reactor instrumentation, reactor vessel and closure head, and supporting test programs. (DG)
1975-11-13
FFTF reactor assembly system technology
International Nuclear Information System (INIS)
An overview is presented of the FFTF reactor and plant together with descriptions of core components, core internals, core system, primary and secondary control rod system, reactor instrumentation, reactor vessel and closure head, and supporting test programs.
1976-03-13
Cytotoxicity of Atriplex confertifolia
UK PubMed Central (United Kingdom)
The search for cancer treatment continues to be a global effort. As part of this global effort, many natural products have been tested against cancer cell lines, mostly from tropically located plants....Full Text Available
2010-01-01
In the study three loss-of-feedwater type experiments which were preformed with the PACTEL facility has been calculated with two computer codes. The purpose of the experiments was to gain information about the behaviour of horizontal steam generator in a ...
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
Certain actively filling plant sucrose sinks such as a seed, a tuber, or a root can be identified by measuring the uridine diphosphate and pyrophosphate-dependent metabolism of sucrose. Sucrolysis in both active and quiescent sucrose sinks was tested and sucrose synthase was found to be the predominant sucrose breakdown activity. Sucrolysis via invertases was low and secondary in both types of sinks. Sucrose synthase activity dropped markedly, greater than fivefold, in quiescent sinks. The test are consistent with the hypothesis that the sucrose filling activity, i.e. the sink strength, of these plant sinks can be measured by testing the uridine diphosphate and pyrophosphate-dependent breakdown of sucrose. Measuring the initial reactions of sucrolysis shows much promise for use in agriculture crop and tree improvement research as a biochemical test for sink ...
1989-04-01
Containment integrated leakage rate test (ILRT) of Indian PHWR
International Nuclear Information System (INIS)
Integrated Leakage Rate Test (ILRT) of containment system plays a very important role in safety of a Nuclear Power Plant. Containment system constitutes the last physical barrier to release of radioactivity from the core and is called upon to mitigate the consequences of not only accidents within the design basis, but also some of the highly unlikely severe accidents. Hence, leak tightness of containment becomes uttermost priority for the safety of plant personnel and public. The containment and associated ESFs are tested before the first criticality and there after periodically during service. The pre-operational integrated leakage rate is carried out at LOCA based design pressure, at periodic test pressure and at some intermediate pressure points to assess the leakage characteristics. This paper summarizes the various requirements and activities relevant to the ILRT of the Indian ...
2005-12-01
Results of reliability test program on light water reactor piping
Energy Technology Data Exchange (ETDEWEB)
The Japan Atomic Energy Research Institute has conducted a piping reliability test program to demonstrate the safety and reliability of light water reactor primary piping. In this program, pipe fatigue test, leak-before-break (LBB) verification test and pipe rupture test were carried out to examine the integrity of piping, to verify the LBB and to demonstrate the effectiveness of protective measures against jet impingement and pipe whip loads under a pipe rupture event.In the pipe fatigue test, a procedure to predict the fatigue crack growth was developed, and the integrity of piping during the plant service life was evaluated. In the LBB verification test, the pipe fracture test and the leak rate test were performed to verify the LBB in the primary piping.In the pipe rupture ...
1994-12-01
Four-inch pipe whip test under BWR LOCA conditions effect of overhang length
Energy Technology Data Exchange (ETDEWEB)
Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous guillotine break of primary coolant piping in nuclear power plants. This paper describes the results of the 4-inch pipe whip tests(RUN 5407, 5501, 5504, 5603), under the BWR LOCA conditions, which were performed from 1979 to 1981. The test pressure was 6.8 MPa and test temperature 285/sup 0/C. In these tests, clearance was kept constant at the value of 100 mm and overhang lengths were 250, 400, 550 and 1,000 mm, respectively. The main purpose of these tests is to investigate the effect of overhang length on pipe whip behavior. From the tests results, the pipe movement is effectively limited by the restraints if the overhang length is 250 mm or 400 mm. The ...
1983-03-01
Test coking of charges containing coal from the Western Donbass and the Karaganda coalfield
In recent years the feedstock base of the coking plants in the South has been significantly degraded: the charges contain an increased quantity of gas coal and coal from coalfields in the East are being included. Certain plants in the Ukraine receive coal from the Kuznetsk, Pechora and Karaganda coalfields. Addition of these coal types in the charges of plants in the South is expected to continue in the future. Their efficient utilization requires careful investigation of the new charges in order to determine the optimal composition and to produce blast furnace coke meeting modern specifications.
1981-01-01
Telephone exchange Feutersoey - first pilot plant of the PTT with solar collectors
Energy Technology Data Exchange (ETDEWEB)
In the course of this year six local exchange offices with alternative heating and hot water plants were started up in Switzerland. They are all of the same building type, designed for not more than 1000 telephone subscribers and for the same architectural conditions. However, the buildings are situated in different areas of the country and are thus subject to different environmental conditions. Solar collectors supplemented by electricity boilers are fitted to two of these objects. Heat pumps are operated in two other exchange offices while the last two are equipped with electric heating devices. For purposes of comparison two new test plants of the same size with oil heating devices are set up.
1981-01-01
United States Department of Energy breeder reactor staff training domestic program
Energy Technology Data Exchange (ETDEWEB)
Two US DOE projects in the Pacific Northwest offer unique on-the-scene training opportunities at sodium-cooled fast-reactor plants: the Fast Flux Test Facility (FFTF) near Richland, Washington, which has operated successfully in a wide range of irradiation test programs since 1980; and the Experimental Breeder Reactor II (EBR-II) near Idaho Falls, Idaho, which has been in operation for approximately 20 years. Training programs have been especially designed to take advantage of this plant experience. Available courses are described.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
Higher efficiencies of steam power plants are achieved by raising the operating temperature and pressure. The use of ferritic steels helps to minimize the cost and enhance the flexibility (two-shift operation, frequent starting and stopping). The COST programme had the long-term goal of developing and testing 9- 12 % Cr steels with high fatigue strength and to produce,test and operate critical components for an advanced steam power plant (steam temperature 600 C and supercritical pressure). (orig.)
1996-12-31
Behavior of the cooling towers as a function of the time
International Nuclear Information System (INIS)
In the scope of the nuclear plants lifetime study, the behavior of the cooling towers is discussed. The main geometrical characteristics of the cooling towers in the French nuclear power plants, are presented. The surveyance program, the risks of accident, the research and development actions are considered. The results of the investigations of the cooling tower structure show that it is a multidiciplinary problem and needs the development of experimental and theoretical methods. Concerning the regenerators, the surveyance actions under operating conditions, the accelerated aging tests, and some aspects of the mechanical resistance, are underlined. It is shown that mainly the creep tests will allow the lifetime estimation of the materials developed for the regenerators.
1988-12-01
Application of power system stabilizer at Bandar-Abbas power station
Energy Technology Data Exchange (ETDEWEB)
System instability as result of high power generation of one of the largest plants of the Iranian electric power grid prevented the plant to be fully utilized. PSSs were installed on the generating units of the power station, to improve its small signal stability, and enhance the stable generation limit. Domain separation and pole assignment techniques were applied for the PSS design. Several field tests were also carried out to verify its effectiveness. This paper presents the PSS tuning procedure, including the design criteria and some of the field test results.
1994-08-01
A study on diagnostic techniques of pump operating condition
Energy Technology Data Exchange (ETDEWEB)
The scope and contents investigate and reviewed are as follows : establishment of study plan and references survey, review of related problems and inservice test standards of safety injection pump in use nuclear power plant, review of the study results in laboratory, the theoretical investigation of temperature rise according to mini-flow rate of pump, mini-flow rate working characteristics of high and low pressure injection pumps at nuclear power plants, setup of testing equipment for measuring ampere, discharge pressure and vibration, selection and behaviors analysis of major parameters concerning pump degradation.
1998-03-15
Thermal fatigue failure at the White Cliffs solar thermal power plant
Energy Technology Data Exchange (ETDEWEB)
The failure of receivers has been one of the main operating problems at the White Cliffs solar thermal power plant. This Technical Note reports the results of an initial investigation that identifies the cause as having been their thermal fatiguing of the tube walls. The fatigue appears to be caused by unstable heat transfer at vapor qualities below the point where critical heat flux is generally exceeded. Methods for avoiding this problem are tested.
1995-02-01
Reliability assessment of hydrothermal generation systems containing pumped storage plant
Energy Technology Data Exchange (ETDEWEB)
Previous models and evaluation techniques based on the Monte Carlo simulation for the reliability assessment of mixed hydrothermal generation systems are extended. Models for reservoirs on multiple rivers and pumped storage plants are developed. Operating and water management policies are extended to include the relative economical effects of operating alternative sources of generation. These effects and the benefits are described and discussed using an extended IEEE reliability test system. (Author).
1991-11-01
International Nuclear Information System (INIS)
This standard describes requirements and provides guidelines for the control of activities to be exercised during procurement of items and services which affect the quality of nuclear power plants. These requirements and guidelines apply to procurement activities for items and services such as designing, purchasing, fabricating, handling, shipping, storage, cleaning, constructing, erecting, installing, inspecting, testing, maintaining, repairing, initial fueling, refueling, and modifying.
New humic plant growth stimulant based on the neogene brown coals of Belarus
British Library Electronic Table of Contents (United Kingdom)
Data on a technology for the manufacture of a new biologically active humic preparation based on the Neogene brown coals deposited in Belarus are presented. The physicochemical properties of the preparation are given, and its biological activity is evaluated; the results of plant cultivation tests in the basic crops of the region?potatoes and grain crops?are also considered.
2011-01-01
Evaluating the metrology of the standard method of determining blast furnace coke strength
Coke strength increases in significance as blast furnace and metallurgical plant gain in size and output requirement. The article underlines the need to apply error computation standards to strength testing routines. The mean square deviation was found for cokes from different plants, related to a single strength determination for M25 and M10, and amounted to 0.61 and 0.35% respectively. The future standards should include a correlation factor for permitted tolerance as between parallel determinations.
1981-03-01
Development of solar agricultural dryers combined with PV modules and solar collectors
Energy Technology Data Exchange (ETDEWEB)
The intention of the research carried out was to develop photovoltaic driven solar heating systems applied for drying of medicinal plants in remote areas. Identification of hybrid photovoltaic - photothermal systems was done and discussion of technical features and applicability of such systems in agriculture is presented. Detail technical specification of PV powered medicinal plants solar dryer and cost effectiveness parameters are given. Operational and economic results obtained during testing of the dryer are promising. (orig.) 4 refs.
1997-12-31
The paper discusses recent work on lime enhancement and testing at the bench-scale, followed by evaluation of the more promising sorbents in a pilot plant to develop low cost, retrofittable flue gas cleaning technology specifically the development of highly reactive sorbents. Con...
Energy Technology Data Exchange (ETDEWEB)
This quarterly report covers the period from January 1, 2005 through March 31, 2005. It covers: technical development, permitting status, engineering status, construction status, operations summary and marketing support activities for this period. Plant startup is still continuing. Testing of admixtures to enhance extrusion and SDA wetting is continuing. Efforts are underway to improve plant availability.
2005-05-01
Energy Technology Data Exchange (ETDEWEB)
Biosorption means the storage of substances at the cell envelope. Different microbial biomasses were tested for the separation of radionuclides from mining waters. Results of a pilot plant demonstrate the ability of these techniques for water cleaning processes. An effluent concentration of lower than 1 mg/l (in most cases 0.1 mg/1) could be realized in a pilot plant by using pure cells of a methylotrophic strain of bacteria as well as using of a fungal mycelia.
1995-12-31
FFTF [Fast Flux Test Facility] fuel handling experience (1979--1986)
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF)is a 400 MW (th) sodium-cooled fast flux test reactor located on the Hanford Site in southeastern Washington State. The FFTF is operated by the Westinghouse Hanford Company for the United States Department of Energy. The FFTF is a three loop plant designed primarily for the purpose of testing full-scale core components in an environment prototypic of future liquid metal reactors. The plant design emphasizes features to enhance this test capability, especially in the area of the core, reactor vessel, and refueling system. Eight special test positions are provided in the vessel head to permit contact instrumented experiments to be installed and irradiated. These test positions effectively divide the core into three sectors. Each sector requires its own In-Vessel Handling Machine (IVHM) to ...
1987-09-01
Heavy metal concentrations in plants and different harvestable parts: A soil-plant equilibrium model
International Nuclear Information System (INIS)
A mathematical interaction model, validated by experimental results, was developed to modeling the metal uptake by plants and induced growth decrease, by knowing metal in soils. The model relates the dynamics of the uptake of metals from soil to plants. Also, two types of relationships are tested: total and available metal content. The model successfully fitted the experimental data and made it possible to predict the threshold values of total mortality with a satisfactory approach. Data are taken from soils treated with Cd and Ni for ryegrass (Lolium perenne, L.) and oats (Avena sativa L.), respectively. Concentrations are measured in the aboveground biomass of plants. In the latter case, the concentration of metals in different parts of the plants (tillering, shooting and earing) is also modeled. At low concentrations, the effects of metals are moderate, and the dynamics appear to ...
2010-08-01
Second international symposium on nuclear power plant life management. Book of extended synopses
International Nuclear Information System (INIS)
The world's fleet of nuclear power plants is, on average, more than 20 years old. Even though the design life of a nuclear power plant is typically 30-40 years, it is quite feasible that many plants will be able to operate in excess of their design lives, provided that nuclear power plant engineers demonstrate by analysis, trending, equipment and system upgrades, increased vigilance, testing and ageing management that the plant will operate safely. In the operation of nuclear power plants, safety should be always the prime consideration. Plant operators and regulators must always ensure that plant safety is maintained, and where possible enhanced, during a plant's operating lifetime. Nuclear power plant life management (PLiM) has gained increased attention ...
2007-10-15
British Library Electronic Table of Contents (United Kingdom)
Summary 1.-The modules of plants experience different levels of resources, and clonal plants can integrate resource heterogeneity. However, no studies have tested whether the benefits of clonal integration depend on patterns of heterogeneity in multiple resources, like high levels of above-ground and below-ground resources in the same patches (-coincident patchiness-) or different patches (-reciprocal patchiness-). 2.-We hypothesized that the benefits of clonal integration can vary depending on whether patchiness is reciprocal or coincident, and that clonal species experience greater benefits from integration when qualitative patterns of resource heterogeneity are more like those likely to occur in their habitats. To test these hypotheses, we grew pairs of connected ramets of Cynodon dacty...
2011-01-01
Soil electrical resistivity -- An essential parameter for power plant design
Energy Technology Data Exchange (ETDEWEB)
Soil electrical resistivity is perhaps the only soil parameter that is used by geologists and geotechnical engineers to explore the subsurface characteristics at a power plant site and also used by civil and electrical engineers as input to their design. A properly designed and executed field electrical resistivity survey is one method of examining the subsurface profile. The same program can provide information about the corrosion potential of the soil that can play a major role in determining the protection needed for buried steel piping and pile foundations. At the same time, the soil conductivity interpreted from the results of the resistivity testing is an integral part of the design of the electrical grounding system for the plant. This paper describes soil electrical resistivity, test procedures to estimate resistivity values, and how these values can best be used to obtain the parameters ...
1996-11-01
Comparison between small LOCA scenarios in Eastern and Western type PWRs
Energy Technology Data Exchange (ETDEWEB)
In the frame of the use of the Relap5 thermal hydraulic code in the predictions of LOCA transient scenarios in PWRs and considering the recent development of a methodology to evaluate the related uncertainty, the response to a Small Break LOCA of Eastern and Western type PWRs has been analyzed. A four loop/horizontal Steam Generator WWER-1000 (KOZLODUY in Bulgaria) and a two loop/vertical U-tubes Steam Generator Westinghouse (KRSKO in Slovenia) nuclear power plants have been considered in the analysis. The reference transient is a 2% equivalent cold leg break accident, without High Pressure Injection System intervention, as specified in the frame of a ``counterpart test`` activity involving experimental tests on four Integral Test Facilities: LOBI (European Community), SPES (Italy), BETHSY (France) and LSTF (Japan). The code results in the two cases, also taking into account the related uncertainty as ...
1996-07-01
Physical modeling of flow control device test in intake structure
International Nuclear Information System (INIS)
The seawater in the intake structure flows into the large pump to with draw excess heat from the turbine steam condenser. In the intake structure of a nuclear power plant, undesirable pump operating characteristics such as vortices, impeller damages and non-uniform pump-approach flow around the pump bells take place frequently due to poorly-arranged intake geometry. In this study, physical modeling test was performed to predict the hydraulic phenomenon, and proposed flow control devices.
2000-05-01
Development of pressurized internally circulating fluidized-bed (PICFB) technology
Energy Technology Data Exchange (ETDEWEB)
After the completion of the 4MWth pilot plant of the Pressurizied Internally Circulating Fluidized-bed Boiler (PICFB), a total of 15 test runs, amounting to 2280 hours of operation, were concluded. The test results have confirmed the superior operating performance. Additionally, Ebara plans to develop a Pressurized Internally Circulating Fluidized-bed Gasifier (PICFG or Advanced PICFB). 8 figs.
1998-07-01
Results are reported from dye tests of the dispersion of the vapor plume from the natural draft cooling tower of a fossil-fuel power plant located in the coastal region of Maryland.
1977-12-01
British Library Electronic Table of Contents (United Kingdom)
Dinarmus basalis Rondani (Hymenoptera: Pteromalidae), an ectoparasitoid of bruchid pests of stored cowpeas (Vigna unguiculata), is a potential biological control agent. We investigated whether grain protectants from Hyptis spicigera and H. suaveolens (Lamiaceae) disturb parasitism and post-embryonic growth of the parasitoid. When cowpeas containing bruchid larvae were treated before being placed in the presence of D. basalis females, the rate of parasitism decreased on average up to 24% and 47% in the presence of, respectively, leaf dry powder and essential oils from both plant species. The estimated larval mortality was higher on treated (9.55 to 28.6%) than on non-treated parasitized hosts (2.8%), depending on the plant species and the plant extract tested. Additional larval mortality wa...
2011-01-01
Dynamic voltage control by remote voltage regulation for pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
This paper presents a new application in dynamic voltage control based on an older method of voltage regulation. The resulting method is suitable for adoption inn multi-unit pumped storage plants. Inherent operation characteristics of pumped storage plants in the pumping mode can created visible load rejection overvoltages on the transmission and the nearby distribution networks and cause customer complaints. This paper proposes a method in which the on-line units' excitation system impedance compensators are utilized to reduce the magnitude of these overvoltages. This paper presents the theoretical background, computer simulation results, and the field test results at the Pacific Gas and Electric Company's Helms Pumped Storage Plant. This paper should be of interest in the areas of power system planning as well as power system operation.
1988-08-01
FFTF operational results: startup to 100 MWd/kg
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400-MW(t) sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory in Richland, Washington, to conduct fuels and materials testing in support of the US liquid-metal fast breeder reactor program. Startup and initial power testing included a comprehensive series of nuclear and nonnuclear tests to verify the thermal and neutronic characteristics of the plant and to demonstrate its inherent safety features. Extensive reactor core characterization measurements were completed to provide the neutron and gamma spectra, fission rates, and other physics data needed to design and evaluate tests irradiated in the FFTF. A specially designed series of natural-circulation tests was performed to demonstrate the inherent safety features of the plant. Early in 1982 the ...
International Nuclear Information System (INIS)
Compared with that of Daya Bay Nuclear Power Plant, the reactor power of QS-II Nuclear Power Plant is decreased and the primary coolant system is changed from three loops to two loops. Thereby the related systems were re-designed, and corresponding tests and engineering validation were carried out. Results of preliminary operation indicate that it is successful. The author describes the design modifications, features and corresponding tests of some systems, reflecting the successful incorporation of engineering and testing, and revealing the capability to develop nuclear power and design the large or medium sized commercial NPP on Self-Reliance in China
2003-02-01
Radiological operating experience at FFTF [Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility has been in operation for approximately five years, including about one thousand days of full power operation of the Fast Test Reactor. During that time the collective dose equivalents received by operating personnel have been about two orders of magnitude lower than those typically received at commercial light water reactors. No major contamination problems have been encountered in operating and maintaining the plant, and release of radioactive gas to the environment has been minimal and well below acceptable limits. All shields have performed satisfactorily. Experience to date indicates an apparent radiological superiority of liquid metal reactor systems over current light water plants.
1987-04-22
Energy Technology Data Exchange (ETDEWEB)
The Heat Cycle Research Program, which is conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. The current testing involves the investigation of binary power cycle performance utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation of the working fluid. The utilization of these concepts verified here will improve the net geofluid effectiveness (net watt hours plant output per pound of geofluid) about 20% over that of a conventional binary power plant. The major effect in this improvement is the ability to achieve integral, countercurrent condensation. Results are presented for the recent testing including those tests examining the performance of the countercurrent condenser at different ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
Experience with the identification and tuning of exciter constants for a generating unit as the Second Nuclear Power Plant of Taiwan Power Company is reported. Field test is first performed on the excitation system with the generator open-circuited. Since the field test results differ from the computer simulation results using manufacturer`s constants, the authors first modify the manufacturer`s constants based on their previous experience to reach a preliminary set of parameters for the excitation system. Then a hybrid nonlinear simulation-sensitivity matrix method is developed to further refine the excitation system parameters. The exciter constants are tuned in order to give better dynamic response before a power system stabilizer is applied to the generator. Field tests are then performed in order to compare the dynamic response of the generator without and with power system stabilizer.
1996-05-01
International Nuclear Information System (INIS)
Experience with the identification and tuning of exciter constants for a generating unit as the Second Nuclear Power Plant of Taiwan Power Company is reported. Field test is first performed on the excitation system with the generator open-circuited. Since the field test results differ from the computer simulation results using manufacturer's constants, the authors first modify the manufacturer's constants based on their previous experience to reach a preliminary set of parameters for the excitation system. Then a hybrid nonlinear simulation-sensitivity matrix method is developed to further refine the excitation system parameters. The exciter constants are tuned in order to give better dynamic response before a power system stabilizer is applied to the generator. Field tests are then performed in order to compare the dynamic response of the generator without and with power system stabilizer.
1995-07-23
CWM production by low rank coals upgrading
Energy Technology Data Exchange (ETDEWEB)
A 8.4 t/d pilot plant was completed in November 1994. Experimental operation for continuous tests have been carried out since December 1994. Two kinds of Indonesian sub-bituminous coals and an Australian lignite were upgraded and slurrified by the end of 1995. Typical pilot test results, such as coal concentration of upgraded sub-bituminous CWM of 65% and 4,700 kcal/kg heating value, were better than the authors expected. And subsequent combustion test in a 200 kg/h furnace was also successfully completed, with results showing very good combustibilities. This R and D is now in its final year, and the authors are conducting combustion tests on a big burner and gasification test, which will be carried out until March 1996. The test results from the pilot plant so far confirm the validity and economic feasibility of the ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
The successful development of coal-fired combined cycle power generation systems require that all component parts are manufactured from appropriate materials and that these materials give predictable in-service performance. High temperature corrosion resulting from coal-derived particulates, deposition and gaseous species, is potentially life limiting for many components in these systems. Realistic laboratory test methods are outlined for gasifier and gas turbine environments and these have been combined with a materials assessment method based on accurate dimensional metrology. Such tests have allowed the production of models of materials performance as well as accurate comparisons between laboratory and plant derived data. These initial models predict the performance of materials well in the gas turbine environment, but tend to under-predict the damage observed in real gasifier environments. The differences found between ...
1997-12-31
International Nuclear Information System (INIS)
At the importance increase of UT (ultrasonic testing) with the application of rules on fitness-for-service for nuclear power plants, JAPEIC (Japan power engineering and inspection corporation) started education training for defect detection and sizing technique. Weld joints specimen with EDM (Electro-Discharged Machining) notches, fatigue cracks and intergranular stress corrosion cracks were tested and practiced repeatedly based on a modified ultrasonic method and the defect size measuring accuracy of the trainees was surely improved. Results of the blind test confirmed effectiveness of education training. (T. Tanaka)
2005-04-01
Psychological test performance in foundry workers exposed to low levels of manganese
Energy Technology Data Exchange (ETDEWEB)
A sample of 30 manganese-exposed foundry workers from two Swedish plants were examined with a partly computerized psychological test battery, comprised of 10 performance tests. Performance of the manganese-exposed workers was compared to that of a matched control group of 60 workers. Matching criteria were age, geographical area, type of work, and the results on a test of verbal comprehension. Performance of the exposed workers was inferior to that of the control group on tests of simple reaction time, digit span, and finger tapping. No correlations were found between performance and the present manganese exposure levels or the number of years employed in manganese work. The results seem to indicate that the present exposure standards for manganese, in Sweden 2.5 mg/m3 and in most other countries 5 mg/m3, are not sufficient to protect workers from negative effects on performance ...
1990-11-01
British Library Electronic Table of Contents (United Kingdom)
A dry interim storage facility has been constructed at the Wolsung power plant in Korea. This dry storage facility has seven separated modules. There are 40 long slender cylinders in one module. In one cylinder, ten baskets where sixty CANDU spent fuel bundles are loaded are stacked and stored. For this dry storage facility, analyses and tests for hypothetical accident conditions that might occur while moving and storing the baskets into a cylinder were performed. In a demonstration test, one of test basket models did not satisfy one of the safety-related requirements. Thus, the revised basket designs were generated using a structural evaluation based on finite element analyses and specimen tests. Among these revised designs, one design was chosen as a final revised basket design. The fina...
2011-01-01
International Nuclear Information System (INIS)
The alloy type 'alloy 800' with its different variants is used for numerous components in high-temperature reactor (HTR) plants, e.g. for hot-gas conductors, the high-pressure part of steam generators, superheaters, steam collecting vessels and live steam conductors. This study deals with the evaluation of creep rupture tests on 28 welded joints of alloy 800 with an accumulated test duration of 410 years, with the objective to obtain quantitative information on a possible loss of strength in comparison with the unwelded material. The longest test period of an individual test amounted to 98,000 h and the analyzed test temperature range lay between 550"0 and 1000"0C. (orig./MM).
1988-11-25
Assessing the internal mechanical integrity of power transformers using vibration tests
Energy Technology Data Exchange (ETDEWEB)
Machine condition monitoring (MCM) has the capability to predict equipment maintenance needs which can reduce forced down-time and facilitate the avoidance of catastrophic failures and the consequential secondary damage. It can be used to allow confident deferral of routine maintenance, and improve equipment performance, availability, reliability and safety. In order to capitalize on the potential benefits of MCM directed toward power transformers two types of vibration tests were conducted on transformers owned and operated by Cargill Inc. and IES Utilities at the Bridgeport corn plant in Eddyville, Iowa. These tests involved collecting vibration signals from the transformer tank walls during transformer energization at no-load and during steady state operation at various loads. These vibration signals were then used to detect deterioration of internal mechanical integrity. Both types of tests ...
1996-12-31
The operating experience for Wolsung Unit 3 commissioning
International Nuclear Information System (INIS)
This is a slide-based oral presentation given to the COG/IAEA: Fifth technical committee meeting on 'Exchange of operating experience of pressurized heavy water reactors' held in Mangalia, Romania on 7-10 September 1998. Since energization of Wolsung Unit 3 station service transformer on July 12, 1996 a line of initial test program was conducted as follows: 1. ILRT/SIT; 2. Pre-operational and Hot Functional testing with a Light Water and without Fuel in Systems; 3. Load D_2O in Moderator System; 4. Initial fuel loading; 5. Load D_2O in PHT System; 6. Hot Functional Testing with Heavy Water and Fuel in Systems; 7. Criticality and Low Power Physics Testing; 8. Power Ascension Test and, then finally, phase-D test; the plant acceptance test was accomplished after having a Mini-Overhaul to prepare for Commercial Operation. ...
1998-09-07
International Nuclear Information System (INIS)
The Four years of the IMPACT, 'Integrated Modular Plant Analysis and Computing Technology', project Phase 1 have been completed. The verification study of Severe Accident Analysis Code SAMPSON prototype developed in Phase 1 was conducted in two steps. First, each analysis module was run independently and analysis results were compared and verified against separate-effect test data with good results. Second, with the Simulation Supervisory System, up to 11 analysis modules were executed concurrently in the parallel environment (currently, NUPEC uses IBM-SP2 with 72 process elements), to demonstrate the code capability and integrity. The target plant was Surry as a typical PWR and the initiation events were a 10-inch cold leg failure. The analysis is divided to two cases; one is in-vessel retention analysis when the gap cooling is effective (In-vessel scenario test), the other is analysis of phenomena ...
1999-07-01
Final phase testing and evaluation of the 500 kW direct contact pilot plant at East Mesa
Energy Technology Data Exchange (ETDEWEB)
The testing performed during the last phase of the geothermal direct contact heat exchanger program utilizing the 500 kW pilot plant provided more insight into the capabilities and limits of the direct contact approach and showed that more work needs to be done to understand the inner workings of a large direct contact heat exchanger if they are to be modeled analytically. Testing of the column demonstrated that the performance was excellent and that the sizing criteria is conservative. The system operated smoothly and was readily controlled over a wide range of operating conditions. Performance evaluation showed pinch differentials of 4/sup 0/F or less and better than predicted heat transfer capability. Testing during this final phase was directed towards establishing the limits of the column to transfer heat. The working column height was shortened progressively to approximately 16 feet from a design ...
1983-12-01
Research on pipe whip and jet under LOCA conditions, (2)
International Nuclear Information System (INIS)
The paper describes the experimental and analytical results of the pipe whip tests performed under the PWR LOCA conditions using 4, 6 and 8 inch test pipes. The tests were carried out at an initial pressure and a temperature of 15.7 MPa and 325 "0C. Two different types of tests were performed. One was the cantilever type pipe whip test using the test pipe of 3000 mm in length and U-shaped restraints. The other was the cross-over leg pipe whip test using a 1/6 model of piping in the PWR nuclear power plants. The cantilever type pipe whip tests were performed to investigate the influences of overhang length and pipe diameter on the pipe whip behavior. The movement of the test pipe is limited effectively by the restraints when the overhang length is short. The restraint force ...
Experimental studies of 6-inch pipe whip tests under BWR LOCA conditions
International Nuclear Information System (INIS)
Series of pipe rupture tests have been performed at the Japan Atomic Energy Research Institute to demonstrate the safety of the primary coolant circuits in the event of pipe rupture in nuclear power plants. The pipe whip tests have been conducted to study the dynamic response of the pipe and restraints. The results of the pipe whip tests using test pipes of 4-inch in diameter under the BWR LOCA conditions (285"0C, 6.8 MPa) were reported in the previous paper F8/5 of the 6th SMiRT. The present paper describes the results of the pipe whip tests using test pipes of 6-inch in diameter. The test pipe was made of Type 304 stainless steel and was 165.2 mm in outer diameter and 11.0 mm in thickness, and was fixed at the pipe support so that the length of the test section was 3000 mm. The restraints were made ...
International Nuclear Information System (INIS)
Iron concentration control in feedwater is one of the most important subjects in water chemistry. Especially for the BWR plants without 100% flow volume of hollow fiber filter (HFF), rather high iron concentration in feedwater is one of the big issues as this causes relatively high radiation dose rate in drywell area. Cation exchange resins especially used in the plants with partial flow rate of HFF are expected to have the important role of capturing iron in feedwater. For this purpose, we have investigated the effective method for using iron absorption characteristics of cation exchange resin. The Cation-Over Layer method (COL) in condensate demineralizers (CD) effectively utilizes these characteristics. In order to demonstrate a performance of the cation overlay method, we had applied this method for three CD vessels at Fukushima Daiichi NPP Unit 3 for testing purpose. The result of this actual plant ...
2009-10-01
Energy Technology Data Exchange (ETDEWEB)
As the first step for development of the corrosion resistant superheater tube materials of 500 C, 100 ata used in high efficient waste-to-energy plants, field corrosion tests of six conventional alloys were carried out at metal temperatures of 450 C and 550 C for 700 and 3,000 hours in four typical Japanese waste incineration plants. The test results indicate that austenitic alloys containing approximately 80 wt% [Cr+Ni] show excellent corrosion resistance. When the corrosive environment is severe, intergranular corrosion of 40{approximately}200 {micro}m depth occurs in stainless steel and high alloyed materials. It is confirmed quantitatively that corrosion behavior is influenced by environmental corrosion factors such as Cl concentration and thickness of deposits on tube surface, metal temperature, and flue gas temperature. The excellent corrosion resistance of high [Cr+Ni+Mo] alloys such as Alloy 625 ...
1995-12-01
International Nuclear Information System (INIS)
As the first step for development of the corrosion resistant superheater tube materials of 500 C, 100 ata used in high efficient waste-to-energy plants, field corrosion tests of six conventional alloys were carried out at metal temperatures of 450 C and 550 C for 700 and 3,000 hours in four typical Japanese waste incineration plants. The test results indicate that austenitic alloys containing approximately 80 wt% [Cr+Ni] show excellent corrosion resistance. When the corrosive environment is severe, intergranular corrosion of 40#approx#200 microm depth occurs in stainless steel and high alloyed materials. It is confirmed quantitatively that corrosion behavior is influenced by environmental corrosion factors such as Cl concentration and thickness of deposits on tube surface, metal temperature, and flue gas temperature. The excellent corrosion resistance of high [Cr+Ni+Mo] alloys such as Alloy 625 is ...
1995-03-26
The analysis of temperature distribution for surveillance Capsule in reactor vessel of YGN unit 1
International Nuclear Information System (INIS)
Generally, Hardening and irradiated brominating phenomena are occurred in the reactor vessel under operation conditions by atomic cavities and creation of impurity atoms which are led by high fast neutron flux. To assure the mechanical integrity of pressure vessel until the end of power plant life after monitoring the sample specimens on the vessel inside, a series of tests is performed over the retrieved surveillance capsule to examine the changes according to the plant operation in accordance with regulations. Monitoring surveillance capsules attached to neutron shield wall of outer core are consists of impact sample, tensile sample and temperature monitor
2007-05-10
Studies on the CRUD Deposition on Fuel Cladding Surface Using AOA Water Chemistry Loop
International Nuclear Information System (INIS)
Axial offset anomaly (AOA) is caused by the deposition of crud on the fuel cladding of a PWR. When significant levels of crud build up on the cladding, boron can accumulate in the pores of the crud as a concentrated solution or solid phase, and cause the flux depression. Numerous studies have been conducted on the primary water chemistry to reduce the amount of crud in the primary circuit to avoid radioactivity buildup and unexpected power transition in the plant. However, experiments on the crud are restricted in the laboratory because the crud is a highly radioactive material. The objective of this study is to develop a test method for simulating the deposition of crud in a nuclear power plant
2010-10-01
Life management of power plant based on structural damage testing
Energy Technology Data Exchange (ETDEWEB)
Life management system is based on the valid nowadays in Estonian power plants regulation documentation. The system allows to estimate stress distribution in components, find computational assessment of cumulated creep damage, determine when and where it is necessary to cut off the particular number of microsamples or take replicas. Finally, the real metal condition may be assessed on the basis of metallographic specimen research and reasonable 3-R decision - run, repair, replacement - made on further component use. (orig.) 6 refs.
1998-12-31
Digital AVR application to power plants
Energy Technology Data Exchange (ETDEWEB)
The digital AVR must have the level of redundancy and control functions that conform to the configuration of the excitation control system and to the importance of a particular generator for the user. The digital AVR is not simply a digital version of the analog AVR, but can realize sophisticated control functions that were difficult to achieve with analog circuits, thus making it possible to enhance the stability of power system by PSS (power system stabilizer). This paper describes the test results of the digital AVRs applied to power plants, their system configuration and functions, as well as the outline of an auto-tuning PSS or AT-PSS planned to be incorporated in the digital AVR in the future.
1993-12-01
Results are reported from initial characterization tests on the environmental effects of the natural draft cooling tower of the Chalk Point Unit 3 oil-fired power plant located on the shore of Chesapeake Bay. Data are included on updraft air velocity, plume drift, and sea salt deposition in relation to meteorological conditions.
1976-05-01
ALKALINE LEACH-FILTRATION PILOT PLANT TESTING OF HOMESTAKE ORE-SECTION 32
Homestake Ore from the Ambrosia Lake District of New Mexico was treated in the Alkaline Leach-- Filtration Pilot Plant at Grand Junction, Colorado. Detailed information on grinding, leaching, flltration, and precipitation in connection with the processing of this ore is given. Autoclave leaching and continuous yellow cake precipitation were employed. The circuit liquors contnined organic material that was detrimental to clariflcation and precipitation and the results show that ihe ore was amenable to the Alkaline Leach--Filtration process only if a special additive was used. (auth)
1958-06-19
Reflux boiling heat removal in a scaled TMI-2 system test facility
International Nuclear Information System (INIS)
An investigation of decay heat removal by the reflux boiling process was performed on a 1/18 linear-scaled test facility simulating the Three Mile Island (TMI-2) primary system. The objective was to clarify reflux boiling phenomena and core cooling effectiveness. Principal test variables included: core power, primary system water and gas inventories, and steam generator secondary-side coolant flow rate. Of 49 tests conducted, 43 achieved a steady-state heat rejection mode within 3 hours. Subsequent analyses identified two distinct reflux boiling modes. Based upon our current understanding, reflux boiling appears to be an effective process for removing decay heat in a broad range of the conditions investigated for a plant of the TMI configuration.
1980-06-01
Five years operating experience at the Fast Flux Test Facility
Energy Technology Data Exchange (ETDEWEB)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 ...
1987-04-01
Five years operating experience at the Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 ...
1987-09-13
Energy Technology Data Exchange (ETDEWEB)
This project seeks to produce sufficient information on the physical and chemical nature of Coolside waste to design and construct physically stable and environmentally safe landfills. Unconfined compressive strength and permeability tests are reported on samples remolded near 90, 95, and 100% of low energy, standard, and modified dry densities. Unconfined compressive strength tests were also performed on some of the samples after permeability tests were completed. Swell tests were initiated on samples from Coolside pilot plant run {number_sign}2 and on a FBC hydrated ash remolded near 95% of standard density and optimum moisture content.
1993-11-01
Assessment of degradation processes in corrosion resistant steels in nuclear power engineering
International Nuclear Information System (INIS)
The possible corrosion damage is discussed of the CrNi and CrNiMo types steels used as structural materials in WWER type nuclear power plants. It includes point and slot corrosion, corrosion cracking and corrosion fatigue as well as corrosion denting. Also discussed are test procedures that simulate operating conditions and are used for assessing the properties of metallurgical products (sheets and tubes) used in nuclear power engineering. Briefly described is a system for testing the said products in an aqueous medium while keeping the test parameters in a narrow range for a long time. Under the defined temperature, pressure and corrosion medium composition, the test specimens in this system can mechanically be loaded, both statically and dynamically or a temperature gradient can be produced at the tube-tube plate joint. (Z.M.). 1 fig., 1 tab., 10 refs.
1987-12-01
Energy Technology Data Exchange (ETDEWEB)
As part of the EPRI Motor-Operated Valve (MOV) Performance Prediction Methodology, a System Flow Model (SFM) has been developed to determine the differential pressure (DP) across MOVs as they are stroked in typical power plant systems. Input to the SFM includes valve flow characteristics (such as flow coefficient) and system characteristics (such as pump head/flow curve). The primary output is differential pressure across the valve at each stroke position. The SFM was validated by comparison with test data from the EPRI Flow Loop Test Program. In this study, we calculated DP using SFM and performed DP test for four MOVs. Compared between calculated DP and test DP of four MOV, respectively good agreements are found. (author). 6 refs., 9 figs., 1 tab.
1999-11-01
Accelerated aging speeds test of instrument reliability
International Nuclear Information System (INIS)
This paper shows how molecular theory paves the way for accelerated aging tests of safety-related equipment in nuclear power plants, as required by NRC qualification programs. Arrhenius' model, based on an equation, provides useful information regarding the extent of molecular change as a function of time and temperature. Critical to determining the aging characteristics and qualified life of organic materials is the activation energy concept, which is derived from information gathered when the molecular reaction of the material is documented over the entire life cycle. In accelerated-aging applications, the importance of the model lies in characterizing the chemical related reactions of materials. The problem with the Arrhenius approach is that, in generating a testing period of reasonable duration, a rather high test temperature must be selected which may lead to an added and unrelated environmental ...
1982-01-01
ENGINEERING DEVELOPMENT OF COAL-FIRED HIGH-PERFORMANCE POWER SYSTEMS
Energy Technology Data Exchange (ETDEWEB)
A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolyzation process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is generated and gas ...
1998-10-01
Transient performance of FFTF [Fast Flux Test Facility] reference fuel
International Nuclear Information System (INIS)
Fourteen irradiated Fast Flux Test Facility (FFTF) fuel pins were subjected to representative overpower transients in six flowing sodium loop experiments conducted in the TREAT reactor. The transient tests were extended to substantial overpower levels well beyond protected levels, with some tests intentionally run to failure to identify failure thresholds and characteristics. Test variables included transient ramp rate (5, 50, and 100 cents/s) and burnup (2 to 58 MWd/kg). Performance limits and failure characteristics were identified, and cladding strain and fuel melting data were obtained for development and verification of transient analysis codes. The test results demonstrated that FFTF Reference fuel pins are capable of surviving overpower levels well beyond the FFTF secondary Plant Protection System (PPS) trip limit of 1.25 times normal rated power. Based ...
1986-09-07
Crushed Salt Constitutive Model
Energy Technology Data Exchange (ETDEWEB)
The constitutive model used to describe the deformation of crushed salt is presented in this report. Two mechanisms -- dislocation creep and grain boundary diffusional pressure solution -- are combined to form the basis for the constitutive model governing the deformation of crushed salt. The constitutive model is generalized to represent three-dimensional states of stress. Upon complete consolidation, the crushed-salt model reproduces the Multimechanism Deformation (M-D) model typically used for the Waste Isolation Pilot Plant (WIPP) host geological formation salt. New shear consolidation tests are combined with an existing database that includes hydrostatic consolidation and shear consolidation tests conducted on WIPP and southeastern New Mexico salt. Nonlinear least-squares model fitting to the database produced two sets of material parameter values for the model -- one for the shear consolidation ...
1999-02-01
Energy Technology Data Exchange (ETDEWEB)
This report describes a comparison result of technical standards applied to instrumentation and control systems for nuclear power plants between in Korea and in Russia. Russia also has a state-run organization authorized to conduct approval, cancellation, and audit in use of nuclear facility or equipment. The Russian standards for nuclear instrumentation and control equipment are analogous with the Korean ones in the aspect of basic concepts and principles. However, there are some differences in document structure, design requirements, qualification test items, depth of contents between two standard systems. The biggest deviation exists in the standard documents for seismic qualification and electromagnetic interference qualification. Korean seismic qualification standard utilizing US approach, defines testing and qualification methods specifically and clearly. Russian standards however provide only conceptual definitions ...
2005-04-15
Suitability of filter ash surfaces as locations for plants
Energy Technology Data Exchange (ETDEWEB)
The possibility of a positive agricultural use of flue gas filter ash from brown coal power plants is investigated. The suggested measure is mixing ash dump surfaces with extremely acidic spoil bank soils, which balances the high pH value of the alkaline ash and contributes to improved nutrient and soil sorptive conditions. Optimum quantity of spoil bank sands in the mixture with ash is between 10% and 40%. The optimum quantity must be determined for each type of ash considering improvement of soil chemical conditions and water retention capacity. Filter ash properties vary widely; the required amount of spoil bank sand added to investigated ash surfaces near 3 brown coal power plants was between 25% and 30% of the mixture. The same favourable soil and ash mixture can be produced by adding 60% to 75% filter ash to acidic raw spoil bank soil surfaces forming a top soil layer in a thickness of minimum 60 cm. Tests of ...
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
We evaluated the similarities between ozone-induced and mite-induced emission of volatile organic compounds (VOCs) from lima beans, and tested the response of the natural enemies of herbivores to these emissions using trophic system of two-spotted spider mites and predatory mites. The acute ozone-exposure and spider mite-infestation induced the emission of two homoterpenes, (E)-4,8-dimethyl-1,3,7-nonatriene and (E,E)-4,8,12-trimethyl-1,3,7,11-tridecatetraene, and (Z)-3-hexenyl acetate. Only plants with spider mite-infestation emitted the monoterpene (E)-{beta}-ocimene. Predatory mites were equally attracted to ozone-exposed and unexposed plants, but discriminated between spider mite-infested and uninfested plants, when both were exposed to ozone. The similarities between ozone and herbivore-induced VOCs suggest that plant defence against phytotoxic ozone and the production of VOCs ...
2004-09-01
International Nuclear Information System (INIS)
Over the past few years, NPCIL has performed comprehensive Level-1 Probabilistic Safety Assessment (PSA) for a 220 MWe Pressurised Heavy Water Reactor (PHWR) at Kakrapar Atomic Power Station (KAPS) and for the first 540 MWe PHWR at Tarapur Atomic Power Project (TAPP- 3 and 4). The major objective of these PSAs was to present an integrated picture of the safety of the plant to identify and understand key plant vulnerabilities. As a result of the availability of these PSAs, there is a desire to use them to operate the plants in the most efficient manner practicable. In recent years, the operation of Indian Nuclear Power Plants has been characterized by improved availability/capacity factors and reduced forced outages. Frequency of planned outages is also being reduced. In order to achieve this, the PSAs are now being used as an engineering tool for optimization of Technical Specifications with regard to ...
2005-12-01
Evaluation of new corrosion-resistant superheater tubing in high-efficiency waste-to-energy plants
Energy Technology Data Exchange (ETDEWEB)
Field corrosion tests were conducted on eight single tube materials and two welded overlay materials in three typical Japanese waste incineration plants in an effort to develop new corrosion-resistant superheater tubes capable of functioning efficiently under temperature and pressure conditions of 500 C and 100 kgf/cm{sup 2}-g in high-efficiency waste-to-energy (WTE) plants. Austenitic alloys containing higher concentrations of chromium, nickel, and molybdenum [Cr + Ni + Mo] showed excellent corrosion-resistant properties, and the new alloys JHN24 and HR30M showed good corrosion resistance. Different corrosion rates found in each of the three plants were explained by differences in operating conditions, such as gas temperature, concentration of molten salts resulting from chlorine (Cl) content of deposits, heavy metal (zinc oxide [ZnO] + lead oxide [PbO]) content, etc. It was confirmed that the ...
1998-07-01
Analysis of exhaust gas visibility in iron ore sintering plant
Energy Technology Data Exchange (ETDEWEB)
Visible smoke of exhaust gas from iron ore sintering plants spoil the scenery around the works. In this paper, the mechanism of formation of visible smoke is discussed by detailed analysis of the exhaust gas components and dust in the Oita No. 1 sintering plant. The main substance of visible smoke was mist condensing in the air during the cooling of exhaust gas that contained 0.1 ppm of sulfuric acid. Sulfuric acid is considered to raise the dew point and so facilitate mist condensation, and to lower the vaporization of visible mist containing sulfuric acid solution. Dust in the exhaust gas is also considered to act as nucleation sites for mist condensation. This proposed mechanism was confirmed by the test remixing SOx-rich gas with desulfurization gas in the Nagoya No. 3 sintering plant. Long trails of visible smoke were observed by remixing SOx-rich gas with exhaust gas. In conclusion, in order to ...
2006-07-01
Mutation breeding in leguminous crop plants
Energy Technology Data Exchange (ETDEWEB)
Since it was introduced in the early 1940's, mutation breeding has been tested on many crops as modern plant breeding. Until now, more than seven hundred varieties have been developed by means of induced mutation, and many of them officially released and approved for registration. Hundreds of papers report the results of mutation breeding, and the characteristics of induced mutation in different kinds of crops were discussed for review purposes (Blixt and Gottschalk 1975, Gottschalk and Wolff 1983). Considering the results already obtained, it can be concluded that the kinds of induced mutation and their utilization vary from crop to crop. This paper summarizes and discusses the mutation characteristics and kinds on the induced mutants of leguminous plants that have been released.
1988-03-01
Incorporation of organizational failures in PSA
International Nuclear Information System (INIS)
A large portion of the work performed at nuclear power plants follows standardized flow paths. For example, although components on which the maintenance crew works differ from one assignment to the next, all assignments basically follow the same process: requesting, reviewing, planning, scheduling, executing, testing, and documenting the work. In general, the term open-quotes work processclose quotes is used to refer to a standardized sequence of tasks designed within the operational environment of an organization to achieve a specific goal. The predictable nature of work processes suggests that a systematic analysis can be conducted to identify the desirable design of the process and to develop performance measures with respect to the strengths and weaknesses in the process. Furthermore, because of the close relationship of the work process to plant performance and plant safety, it is believed that ...
1993-06-20
Effect of zinc and its form of supply on production and quality of coffee beans
British Library Electronic Table of Contents (United Kingdom)
Abstract BACKGROUND: In Brazil, the usual forms of zinc (Zn) supply to coffee plants have limitations that compromise the element availability to the plant. This study proposes to test an alternative approach to supplying the nutrient to Coffea arabica L. using trunk implanted zinc tablets. Additionally, the effect of Zn on the production and quality of coffee beans was also evaluated. RESULTS: The highest total coffee bean production was recorded in plants implanted with Zn tablets (TA), while the lowest was recorded in the control treatment, without zinc supply (WZn), reaching a bianual production of 188.2 and 130.1 60-kg bags of processed beans per hectare, respectively. In the treatments where Zn were applied as tablet implantation or as foliage spraying (SZn); the bean size was larger...
2011-01-01
Ceramic linings beat coal plant's abrasion/corrosion problems
Energy Technology Data Exchange (ETDEWEB)
A combination of erosion and corrosion at the Victoria Junction coal preparation plant in Sydney, Nova Scotia was causing serious problems. Schedule 80 mild steel pipes were starting to fail as well as some quarter-inch steel plates in the lauders and chutes. Some corrosion tests were carried out and the high chloride level in the process water was felt to be the single most important contribution to the corrosion problem. Cast basalt was selected as a solution to the pipe wear problem. Three different types of abrasion/corrosion-resistant tiling - basalt tiles, kalceram tiles and ceramic tiles were well suited to the chloride conditions at this plant.
1985-07-01
Test of use of MN-4 oil in 110 to 220 kV cable lines
Energy Technology Data Exchange (ETDEWEB)
Beginning in 1972 low-pressure cables filled with MN-4 oil produced by the Yaroslav Petroleum Processing Plant arrived at the Leningrad Cable Network of the Leningrad Rayon Power Administration. Lines formed with these cables have been successfully used. The parameters of the oil in them have not changed with respect to the values present when the lines were placed in operation. However, from here on filling in of the 110 to 220 kV input lines of low and high pressure will be accomplished with MN-4 oil produced by the Gorkiy Petroleum Processing Plant. Because petroleum from various fields and the properties of the oil produced from it are unlike, samples were taken from some elements of the lines filled in with MN-4 oil. The results of the tests are described.
1980-09-01
Safety designs for sludge ducts in brown coal briquetting plants
Energy Technology Data Exchange (ETDEWEB)
Studies technological safety of installing a water spray pressure vessel between electrostatic dedusters and coal sludge ducts. These sprays are in use elsewhere for steam generator ash removal. Dust ignition and explosion tests were carried out to examine flame and pressure wave propagation through the vessel into ducts. Water jet diameter, amount of water sprayed and coal dust removed were varied. Pressure waves exceeded 250 Pa. Test results show the vessel to be suitable for installation in briquetting plants due to its flame and explosion barrier effect and extermination of smoldering dust fires. The only disadvantage of the vessel is seen as its water and electric power consumption; about 8/sup 3//h of water and 1.5 kW/h of power per vessel serving dedusters of a 2,200 m/sup 2/ rotary brown coal dryer.
1987-06-01
Energy Technology Data Exchange (ETDEWEB)
The Heat Cycle Research Program, which is conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. The current testing involves the investigation of the performance of binary power cycles utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation. The utilization of these concepts will improve the net geofluid effectiveness (net plant output per unit mass of geofluid) about 20% over that of a conventional binary power plant. The major prerequisite for this improvement is the achievement of integral, countercurrent condensation. Results are presented for testing of the performance of the condenser at different tube inclinations. The performance in the vertical orientation is better than in either the horizontal or ...
1989-01-01
International Nuclear Information System (INIS)
Weld metal, base material and stainless steel overlay specimens for Charpy tests and static tensile tests were irradiated for a year in a power reactor of the Bohunice nuclear power plant in place of the evaluated surveillance specimens. The material of the specimens was identical with that of the WWER-440 reactor pressure vessels, and was exposed to a fluence of (1.2 - 4.5) x 10"2"3 m"-"2 (E > 0.5 MeV) at approximately 270 degC. Some of the irradiated as well as unirradiated specimens were subjected to regeneration annealing at 475 degC for 168 h. The behavior of the materials after irradiation and annealing was evaluated. (author). 33 tabs., 32 figs., 8 refs.
Energy Technology Data Exchange (ETDEWEB)
Pilot plant tests have been conducted to evaluate sodium thiosulfate as an oxidation inhibition additive in five lime/limestone slurry flue gas desulfurization processes. It was found that the oxidation rate of absorbed sulfur dioxide (SO/sub 2/) was reduced by more than 50 percent in the presence of 100 to 200 ppm of thiosulfate ion in the scrubbing slurry. Calcium sulfate dihydrate (gypsum) scaling was eliminated and the unsaturated (with respect to gypsum) operation mode was maintained by the addition of sodium thiosulfate. Other benefits of sodium thiosulfate addition observed at the pilot plant included improvement in solids dewatering properties for limestone processes.
1985-01-01
Pilot testing of sodium thiosulfate
Energy Technology Data Exchange (ETDEWEB)
Pilot plant tests have been conducted to evaluate sodium thiosulfate as an oxidation inhibition additive in five lime/limestone slurry flue gas desulfurization processes. It was found that the oxidation rate of absorbed sulfur dioxide (SO)/sub 2/ was reduced by more than 50 percent in the presence of 100 to 200 ppm of thiosulfate ion in the scrubbing slurry. Calcium sulfate dihydrate (gypsum) scaling was eliminated and the unsaturated (with respect to gypsum) operation mode was maintained by the addition of sodium thiosulfate. Other benefits of sodium thiosulfate addition observed at the pilot plant included improvement in solids dewatering properties for limestone processes and improvement in SO/sub 2/ removal efficiency for magnesium-enhanced lime/limestone processes.
1986-11-01
Pilot testing of sodium thiosulfate
Energy Technology Data Exchange (ETDEWEB)
The article gives results of pilot-plant tests to evaluate sodium thiosulfate as an oxidation-inhibition additive in five lime/limestone slurry flue-gas desulfurization processes. It was found that the oxidation rate of absorbed SO/sub 2/ was reduced by more than 50% in the presence of 100-200 ppm of thiosulfate ion in the scrubbing slurry. Calcium sulfate dihydrate (gypsum) scaling was eliminated and the unsaturated (with respect to gypsum) operation mode was maintained by the addition of sodium thiosulfate. Other benefits of sodium thiosulfate addition observed at the pilot plant included improvement in solids dewatering properties for limestone processes and improvement in SO/sub 2/ removal efficiency for magnesium-enhanced lime/limestone processes.
1986-01-01
Pilot testing of sodium thiosulfate
Energy Technology Data Exchange (ETDEWEB)
The article gives results of pilot-plant tests to evaluate sodium thiosulfate as an oxidation-inhibition additive in five lime/limestone slurry flue-gas desulfurization processes. It was found that the oxidation rate of absorbed SO/sub 2/ was reduced by more than 50% in the presence of 100-200 ppm of thiosulfate ion in the scrubbing slurry. Calcium sulfate dihydrate (gypsum) scaling was eliminated and the unsaturated (with respect to gypsum) operation mode was maintained by the addition of sodium thiosulfate. Other benefits of sodium thiosulfate addition observed at the pilot plant included improvement in solids dewatering properties for limestone processes and improvements in SO/sub 2/ removal efficiency for magnesium-enhanced lime/limestone processes.
1986-11-01
Causes of denting. Volume 1. Summary report. Final report
This summary report outlines the work that was performed to gain a more complete understanding of denting corrosion of steam generators in PWRs. Background laboratory and plant data on denting were compiled, reviewed and correlated to determine how various exposure conditions affect denting. Two high-temperature chemistry analytical models were reviewed and evaluated by experimental simulation of impurity concentration in the heat transfer and isothermal capsule tests. Simulation of impurity concentration for three cooling waters (lake, river, and cooling tower) was evaluated. The effects of species concentration (Cu/sup + +/, Cl/sup -/, O/sub 2/, and H/sup +/), contaminant thresholds (established by isothermal and heat transfer tests), and heat flux as indicated by superheat on denting were examined. A discussion of several pertinent observations and conclusions drawn from these tasks (as they pertain to ...
1984-05-01
A study on the experimental verification for the pipe whip problem in a Nuclear Power Plant
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to investigate on the experimental verification analysis for the pipe whip problems and to obtain the quantitative evaluation technologies for the design technique of pipe whip restraints. These will contribute to the advance of nuclear regulatory technologies and enhance nuclear power plant safety. This study presents the experimental and transient analytical results of pipe whip tests using the 4', 6' diameter pipe and U-shaped restraints. In the tests, the effects of the overhang length, clearance, impact height on the pipe whip behavior of the pipe-restraints were investigated. The transient impact analysis of the pipe-restraint system was conducted by the finite element program ABAQUS. The applicability of the ABAQUS program to the pipe whip analysis is made clear through this analysis.
1993-12-15
Development status of Severe Accident Analysis Code SAMPSON
International Nuclear Information System (INIS)
The Four years of the IMPACT, 'Integrated Modular Plant Analysis and Computing Technology' project Phase 1 have been completed. The verification study of Severe Accident Analysis Code SAMPSON prototype developed in Phase 1 was conducted in two steps. First, each analysis module was run independently and analysis results were compared and verified against separate-effect test data with good results. Test data are as follows: CORA-13 (FZK) for the Core Heat-up Module; VI-3 of HI/VI Test (ORNL) for the FP Release from Fuel Module; KROTOS-37 (JRC-ISPRA) for the Molten Core Relocation Module; Water Spread Test (UCSB) for the Debris Spreading Model and Benard's Melting Test for Natural Convection Model in the Debris Cooling Module; Hydrogen Burning Test (NUPEC) for the Ex-Vessel Thermal Hydraulics Module; PREMIX, PM10 (FZK) for the Steam Explosion ...
2000-11-01
Energy Technology Data Exchange (ETDEWEB)
Personnel from Martin Marietta Energy Systems, Inc. (Energy Systems) manage a closed hazardous waste disposal unit the Chestnut Ridge Security Pits (CRSP), located on the crest of Chestnut Ridge near the Y-12 Plant, Oak Ridge, Tennessee. To investigate the discharge of groundwater from CRSP to springs and streams located along the flanks and base of Chestnut Ridge, an initial dye-tracer study was conducted during 1990. A hydraulic connection was inferred to exist between the injection well (GW-178) on Chestnut Ridge and several sites to the east-northeast, east, and southeast of CRSP. A second dye-tracer study was conducted in 1992 to verify the results of the initial test and identify additional discharge points that are active during wet-weather conditions. No definitive evidence for the presence of dye was identified at any of the 35 locations monitored during the second dye study. Although interpretations of the initial dye ...
1994-01-01
Power system stabilizer application in a two unit plant analytical studies and field tests
Energy Technology Data Exchange (ETDEWEB)
The use of excitation system controls, specifically the Power System Stabilizer (PSS), to improve damping of power system oscillations and thus extend steady-state stability limits has been a subject of great interest in recent years. The desire to more fully utilize transmission capacity led to the installation of PSS controls on greater numbers of generating units to maintain stability margins. This paper addresses the tuning and adjustment of PSS controls in a two unit power plant. Both analytical studies and field test confirmations are presented. The practical difficulties of verifying the PSS control loop gain margin by testing are explored. A simplified procedure is outlined. The Lower Colorado River Authority (LCRA), Fayette Power Project (FPP) consists of two 683.7 MVA tandem compound steam turbine driven generators. The excitation systems are of the alternator rectifier type and the PSS control utilizes shaft ...
1983-02-01
Numerical Simulation of a Compartment Fire in a Nuclear Power Plant Containment Building
International Nuclear Information System (INIS)
The current trend towards the increased use of risk assessment in the regulation of nuclear power plants will inevitably result in changes in the analysis of fire protection systems and the methods of analysis. Before fire protection can be regulated on a risk basis, a consensus must be reached on a number of issues. One key issue is what types of computational tools will be allowable for analyzing fire events, and what types of scenarios those tools will be approved for use. Reaching this consensus will require an understanding of the types of computational tools available and their inherent advantages and disadvantages. To aid with this understanding, three different methods of fire simulation are applied to an oil pool fire test in the HDR (Heiss Dampf Reaktor) containment test facility. These methods are a hand calculation, the zone model code CFAST (Consolidated Model of Fire Growth and Smoke Transport), and the ...
2002-04-14
Product yield and hydrogen consumption selectivity tests for coal liquefaction catalyst development
A method for analyzing the experimental results of coal liquefaction reactions which is applicable to a number of aspects of coal liquefaction research and process control, including rapid selectivity and performance screening for catalysts; correlation of laboratory results with process parameters; and optimization of product yield with plant process conditions is described here. Ternary diagrams of product/by-product distributions for the coal liquefaction using Co/Mo catalysts combined with a hyperbolic relationship for the conversion of various hydrocarbon fractions can be used for catalyst screening. A hydrogen consumption diagram used to provide a more significant selectivity test than the hyperbolic correlation is also included. (BLM)
1981-01-01
Pipe whip: a summary of the damage observed in BNL pipe-on-pipe impact tests
Energy Technology Data Exchange (ETDEWEB)
This paper describes examples of the damage resulting from the impact of a whipping pipe on a nearby pressurised pipe. The work is a by-product of a study of the motion of a whipping pipe. The tests were conducted with small-diameter pipes mounted in rigid supports and hence the results are not directly applicable to large-scale plant applications where flexible support mountings are employed. The results illustrate the influence of whipping pipe energy, impact position and support type on the damage sustained by the target pipe.
1987-01-01
Pipe whip: a summary of the damage observed in BNL pipe-on-pipe impact tests
International Nuclear Information System (INIS)
This paper describes examples of the damage resulting from the impact of a whipping pipe on a nearby pressurised pipe. The work is a by-product of a study of the motion of a whipping pipe. The tests were conducted with small-diameter pipes mounted in rigid supports and hence the results are not directly applicable to large-scale plant applications where flexible support mountings are employed. The results illustrate the influence of whipping pipe energy, impact position and support type on the damage sustained by the target pipe. (author).
Oak Ridge National Laboratory (ORNL) has for over ten years provided materials testing and failure analysis services to various coal conversion and utilization facilities in the United States. ORNL was involved in these types of activities at all four of the major coal liquefaction pilot plants. This paper presents a summary of activities at Wilsonville over the past two and one-half years. Some details of these activities are discussed below. Failure analysis of elastomers, stainless steels, and alloys is discussed. 6 refs., 9 figs., 13 tabs.
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
The report covers the results of exposing materials for steam turbines to increased steam temperatures in two modules of the KOMET 650 testing facility at the Westfalen power plant. Ferritic/martensitic steels with 9 to 12% Cr and austenite and nickel-based alloys were investigated. Some experimental coatings on low-alloy Cr steel were also tested. The principal findings are presented. It will become possible to construct advanced power stations to be operated at higher temperatures. (orig.)
2008-07-01
FFTF operating experience 1982-1984
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400 MWt sodium-cooled fast reactor operated by Westinghouse Hanford Company for the US Department of Energy to conduct fuels and materials testing in support of the US Liquid Metal Fast Breeder Reactor programme. Early in 1982, the FFTF began its first 100 day irradiation cycle. Since that time the plant has operated very well, achieving a cycle capacity factor of 94 per cent in the most recent irradiation cycle. The authors describe the results achieved in the first three cycles of operation and carrying through to the fourth reactor cycle which began in January 1984. (author).
International Nuclear Information System (INIS)
LOCA (Loss of coolant accident) resistant heat-shrinkable polymeric products are widely used for the connection of LV cables for class 1E systems inside the containment area of nuclear power plants. The paper/presentation describes the verification of a reformulated compound for these products, where certain components of the compound formulation had to be substituted. A qualification programme with this so-called reformulated compound was undertaken to proof the equivalency of the products to the products made out of the original compound. The basic elements of this requalification project were material qualification tests including accelerated aging tests according to the arrhenius method and type tests in accordance to IEEE 383, including flammability tests. The test results showed that the products made out of the reformulated compound were similar in fit, ...
2005-06-15
Evaluation of new corrosion resistant superheater tubings in high efficiency waste-to-energy plants
Energy Technology Data Exchange (ETDEWEB)
In order to develop new corrosion resistant superheater tubes capable of functioning efficiency under temperature and pressure conditions of 500 C and 100 ata used in high efficient waste-to-energy (WTE) plants, field corrosion tests were conducted on eight single tube materials and two welded overlay materials at metal temperatures of 450 C and 550 C for 700 and 3,000 hours, respectively, in three typical japanese waste incineration plants. The test results indicate that austenitic alloys containing higher concentrations of [Cr + Ni + Mo] show excellent corrosion resistant properties and new alloys of JHN24 and HR30M have good corrosion resistance. The different corrosion rate found for each of the three plants could be explained by differences in the severity of corrosion factors, such as, gas temperature, concentration of molten salts due to Cl content of deposits, and heavy ...
1997-08-01
Development of next-generation light water reactor in Japan
International Nuclear Information System (INIS)
In Japan, the development of next-generation Light Water Reactor has been launched since April 2008. The development program will be completed in 2015. The purpose of development is to cope with the replacement for existing nuclear power plants after 2030 in Japan and the expanding demand for nuclear power in the world; 'Nuclear Renaissance.' The reactor also aims to be global standard at around 2030. The requirements for global standard and domestic users have been investigated through the feasibility study of past 2 years, 2006-2007, and six innovative features or 'Core-Concepts' were established as follows. A) Reactor core system with uranium enrichment above 5% for significant decrease of spent fuel discharge and prominent higher availability B) Long-life materials and innovative water chemistry technologies for 80 years plant lifetime and significant reduction of occupational dose C) Seismic isolation technologies to standardize ...
2009-10-27
Optical Fiber Sensor Package Development for the SIT of Containment Structure
International Nuclear Information System (INIS)
Various types of nuclear power plants are being constructed and operated in Korea, and in terms of regulatory control, a method of examining and evaluating the structural integrity of containment structure is being used. Generally, after the construction has been completed, all containment structure go through a Structural Integrity Test(hereinafter SIT) in which the displacement occurring in a structure under greater internal pressure than it was designed for is measured and the result is comparatively assessed with the allowed criteria. Most of the nuclear power plants in Korea are American type plants and their SIT uses the Invar-wire and Extensometer methods. These existing methods are expected to be used for the APR1400 plant currently being built unless some other reliable alternative technique is presented. This tendency can be observed in other countries, such as Japan, and ...
2010-10-01
Laser Sensor Package Development for the SIT of Containment Structure
International Nuclear Information System (INIS)
Various types of nuclear power plants are being constructed and operated in Korea, and in terms of regulatory control, a method of examining and evaluating the structural integrity of containment structure is being used. Generally, after the construction has been completed, all containment structure go through a Structural Integrity Test(hereinafter SIT) in which the displacement occurring in a structure under greater internal pressure than it was designed for is measured and the result is comparatively assessed with the allowed criteria. Most of the nuclear power plants in Korea are American type plants and their SIT uses the Invar-wire and Extensometer methods. These existing methods are expected to be used for the APR1400 plant currently being built unless some other reliable alternative technique is presented. This tendency can be observed in other countries, such as Japan, and ...
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
Success in improving hydropower project efficiency has opened more global markets for variable-speed generator technology. Manufacturers continue to test the markets as the technology evolves. The potential of variable-speed application becomes evident considering that more than 150 pumped storage plants, with a combined capacity exceeding 100,000 MW, are in operation globally.
1993-10-01
Energy Technology Data Exchange (ETDEWEB)
This article describes acoustic methods used in the in-service inspection of the dams and peripheral concrete structures of the Toktogul, Kurpsai, and Bratsk hydroelectric and pumped storage plants. The tests were conducted to assess the compression strength, elasticity, and tensile strength of the concretes. Comparative evaluations against drill core studies proved the acoustic methods to be sufficiently accurate in predicting aging behavior and loss of mechanical and physical integrity in the concretes.
1987-09-01
International Nuclear Information System (INIS)
The first Advanced Boiling Water Reactor (ABWR) started commercial operation as Tokyo Electric Power Company's (TEPCO) Kashiwazaki-Kariwa Nuclear Power Station Unit No.6 (K-6) in November 1996 and its sister Unit No.7 (K-7) in July 1997. The ABWR was developed to achieve higher reliability and safety margin while improving overall operability and economics. To achieve these goals, the optimal Boiling Water Reactor (BWR) technologies had been studied, tested and were finally adopted into the ABWR design. These technologies were called 'First of a Kind' and include the Reactor Internal Pump (RIP), Fine Motion Control Rod Drive (FMCRD), Reinforced Concrete Containment Vessel (RCCV), and integrated digital Instrumentation and Control System (I and C). Intensive development study, confirmation tests and verification tests were conducted by the plant equipment suppliers, electric utilities, and government ...
1999-12-01
System 80+trademark Standard Design: CESSAR design certification
International Nuclear Information System (INIS)
This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80"+trademark Standard Design. This volume 11 discusses Radiation Protection, Conduct of Operations, and the Initial Test Program.
Summary of Initial Testing of SuperLig 644 at the TFL Ion Exchange Facility
Energy Technology Data Exchange (ETDEWEB)
Research at the Savannah River Technology Center aided development of a technical design basis for a Waste Treatment Plant (WTP) to pre-treat and vitrify Hanford tank waste as part of the River Protection Project (RPP). The research addresses safety concerns, process optimization, and waste form compliance. This program will provide technical data to ensure that the process functions as it was designed and minimizes costs.
2001-04-17
Reactor component inventory system at FFTF
International Nuclear Information System (INIS)
A reliable inventory control system was developed at the Fast Flux Test Facility (FFTF) to keep track of the occupancy of 900 refueling facility locations, to compile historical data on the movement of each reactor assembly, and to simulate assembly moves. The simulate capability is valuable because it allows verification of documents before they are issued for use in the plant, and eliminates the possibility of planning illegal or impossible moves. The system is installed on a UNIVAC 1100 computer and is maintained using a data base management system by Sperry Univac called MAPPER.
1985-09-08
Energy Technology Data Exchange (ETDEWEB)
The objective of Phase IV of the contract is to design a conceptual flue gas treating unit based on the fluidized-bed Copper Oxide (FBCO) process for a new coal-fired 500 MW(e) power plant. A technical and economic evaluation of the FBCO process, based on the conceptual design, will also be completed. Progress is described.
1993-09-01
Oceans 82 conference record: Industry, government, education. partners in progress
Energy Technology Data Exchange (ETDEWEB)
Separate abstracts were prepared for 20 papers in this conference report and includes all papers in the ''engineering'' section (program E). Ocean thermal energy conversion (OTEC), moorings, cables, corrosion protection, corrosion testing, coatings, offshore platforms, pipelines, OTEC models and pilot plants, and energy transfer are topics discussed.
1982-01-01
New safety device announced for nuclear power plants
International Nuclear Information System (INIS)
An Ottawa-based company, ECS-Power Systems Inc., has successfully completed a series of tests on an innovative device called a hydrodynamic port (HDP), which makes it possible to automatically initiate and maintain emergency cooling of a nuclear reactor core by natural processes, without relying in any way on human intervention, instrumentation, electric power, valves or moving parts of any kind.
International Nuclear Information System (INIS)
Radionuclide x-ray fluorescence method was used in the determination of Cr, Ni and other heavy metals content in wastewater of an engineering plant taken both before and after chemical treatment. Toxic effects of the wastewaters using Allium cepa root tip cells were tested. (author) 8 refs.; 2 tabs.
1994-05-01
The report describes the site specific changes required to convert an existing lime FGD system to a limestone system enhanced by dibasic acid (DBA) or adipic acid, and the costs of making such a change. In 1982-83, pilot plant tests were conducted at the R. D. Green Station of Bi...
Development of technical information basis of aging management for nuclear power plants
International Nuclear Information System (INIS)
In order to implement effective safety regulations on aging management for reactor facilities etc., the information on important technology issues, the latest technical knowledge including evaluation technology, test and research outcomes, related codes and standards, regulation information, operation experiences such as accidents and trouble, etc. with respect to aging-induced deterioration in and outside Japan and in other industries, were collected, organized and evaluated. (author)
2007-08-01
Energy Technology Data Exchange (ETDEWEB)
The experiments and the test facilities for the study of the stratification phenomenon in the hot plenum of reactor and the upper parts of the steam generator collectors in a nuclear power plant are described. The aim of the experiments was to define the conditions of the stratification initiation, to study the temperature field in the upper part, the definition of the characteristics in the stratification layer, and also to study the factors which cause the intensity of the stagnant volume cooling.
1997-12-31
Coal liquefaction. Quarterly report, January--March 1976
ERDA's coal liquefaction program is reviewed, especially the progress with several pilot plant operations. Other items involve the possible recovery of organic chemicals from coal liquids, the filtration of coal liquids, some experiments on hydrogenation and carbonization, and renovation of the Cresap materials and equipment test facility. (LTN)
1976-01-01
Tabulated data are presented from air monitoring studies in the vicinity of the Chalk Point fossil-fuel power plant located in a coastal region of Maryland. (ERA citation 02:057363)
1977-01-01
Experimental studies of 4-inch pipe whip test under BWR LOCA conditions
Energy Technology Data Exchange (ETDEWEB)
Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous circumferential guillotine break of primary coolant piping in nuclear power plants. The present paper describes the results of the pipe whip tests using test pipes of 4 inch diameter, under the BWR LOCA conditions, which were performed from 1979 to 1981. The tests were carried out at an initial pressure of about 6.8 MPa and an initial temperature of about 285/sup 0/C. The test pipe was 114.3 mm (4 in) in diameter, 8.6 mm in thickness and 4500 mm in length. The four pipe whip restraints used in the tests were the U-bar type of 8 mm in diameter and frabricated from Type 304 stainless steel. The experimental parameters were the clearance (30, 50 and 100 mm) and the overhang length (250, ...
1983-10-01
Experiments with the HORUS-II test facility
Energy Technology Data Exchange (ETDEWEB)
Within the scope of the German reactor safety research the thermohydraulic computer code ATHLET which was developed for accident analyses of western nuclear power plants is more and more used for the accident analysis of VVER-plants particularly for VVER-440,V-213. The experiments with the HORUS-facilities and the analyses with the ATHLET-code have been realized at the Technical University Zittau/Goerlitz since 1991. The aim of the investigations was to improve and verify the condensation model particularly the correlations for the calculation of the heat transfer coefficients in the ATHLET-code for pure steam and steam-noncondensing gas mixtures in horizontal tubes. About 130 condensation experiments have been performed at the HORUS-II facility. The experiments have been carried out with pure steam as well as with noncondensing gas injections into the steam mass flow. The experimental simulations are characterized as accident simulation ...
1997-12-31
The Benchmark Test Results of QNX RTOS
International Nuclear Information System (INIS)
A Real-Time Operating System(RTOS) is an Operating System(OS) intended for real-time applications. Benchmarking is a point of reference by which something can be measured. The QNX is a Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available Personal Computer(PC) for applications such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS). The ELMSYS PC Hardware is being qualified by KTL(Korea Testing Lab.) for use as a Cabinet Operator Module(COM). The QNX RTOS is being dedicated by Korea Atomic Energy Research Institute (KAERI). This paper describes the outline and benchmarking test results on Context Switching, Message Passing, Synchronization and Deadline Violation of QNX RTOS under the ELMSYS PC platform
2010-10-01
Reactor cover gas monitoring at the Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400-megawatt (thermal) sodium-cooled reactor designed for irradiation testing of fuels, materials and components for LMRs. It is operated by the Westinghouse Hanford Company for the US Department of Energy on the government-owned Hanford reservation near Richland, Washington. The first 100-day operating cycle began in April 1982 and the eighth operating cycle was completed in July 1986. Argon is used as the cover gas for all sodium systems at the plant. A program for cover gas monitoring has been in effect since the start of sodium fill in 1978. The argon is supplied to the FFTF by a liquid argon Dewar System and used without further purification.
1986-09-24
Liquid metal reactor cover gas purification and analysis in the USA
International Nuclear Information System (INIS)
Two sodium cooled reactors are currently being operated in the United States of America for the US Department of Energy. These are Experimental Breeder Reactor 11, EBR-11, and the Fast Flux Test Facility, FFTF. EBR-11 is located near Idaho Falls, Idaho, and the FFTF is near Richland, Washington. These reactors are currently engaged in a wide range of testing including fuels and materials tests, and plant system performance and safety development. The US DOE program also includes designs of a next generation sodium cooled power reactor. The FFTF and EBR-11 communities are providing input to these designs. This paper discusses the efforts to develop and operate cover gas systems for the sodium cooled nuclear reactor program in the USA.
1986-09-24
Experimental study on Satureja montana as a treatment for premature ejaculation
British Library Electronic Table of Contents (United Kingdom)
Aim of the study: Satureja montana (winter savory) is a medicinal plant traditionally used to treat different disorders including male sexual dysfunction. In this study we evaluated the effect of Satureja montana hydroalcoholic extract on copulatory behavior of sexually potent male rats. Materials and methods: The extract was orally administered acutely or repetitively for 8 consecutive days at the doses of 25 and 50mg/kg. The main parameters of sexual behavior, mount (ML), intromission (IL), ejaculation (EL) latencies and post-ejaculatory interval (PEI), were evaluated in animals submitted to mating test and multiple ejaculations test. Testosterone serum levels were measured in rats acutely treated with Satureja montana extract dosed at 50mg/kg. In addition the open field test was conduct...
2011-01-01
Characteristics of the flow-controlled accumulator
International Nuclear Information System (INIS)
Mitsubishi is developing a new type of accumulator incorporating the technology of fluidics as one of the seeds for the improved safety of the newly constructed pressurized water reactor plants. This accumulator employs a vortex flow control device, called a vortex damper, as a fluidic device to simplify the safety systems. A fundamental experimental study with a one-fifth scale model and confirmation tests with a one-third scale model to develop the vortex damper have been carried out, and satisfactory results have been achieved. The results of the confirmation tests under the prototype pressure conditions agree well with the basic tests. The flow rate ratio can be 5 to 6. The pressure loss coefficient in the large flow rate period is 8. A cavitation factor is the main parameter of the flow rate coefficient.
Probabilistic fracture assessment of TAPP 3-4 PHT piping
International Nuclear Information System (INIS)
Methodology based on probabilistic fracture mechanics (PFM) is finding increasing acceptability in demonstrating safety of Nuclear Power Plant (NPP) piping. In PFM, the methods of fracture mechanics and reliability theory are combined for assessing the reliability of components, which contain cracks. In this work, reliability assessment of Tarapur Atomic Power Plant (TAPP) 3-4 Primary Heat Transport (PHT) piping is done using PFM. Monte Carlo simulation with stratified sampling is used as a variance reduction technique. PFM model assumes a pre-existing circumferential surface crack before the start of plant operation. The crack grows in size during the lifetime of the plant due to the fatigue loading. This part-through wall crack having escaped hydro-test and pre-service inspection, may result in either a through wall flaw (leak) or may lead to the rupture of the piping. R6 method ...
2005-12-01
International Nuclear Information System (INIS)
Full text: The excessive use of chemical pesticides to control agricultural pests is becoming alarming. The objective of this study is to search for biopesticides of plant origin that could be used to control one of the major pest of fruit production; the Mediterranean fruit fly (Ceratitis capitata Wied.). A colony of the Lebanese wild strain of this insect was reared under laboratory condition to provide biological material. The insecticidal activity of the essential oils extracted from aromatic plants in Lebanon was assessed. The tested plants are: Foeniculum vulgare, Thymbra spicata, Artemisia herba alba, Origanum syriacum, Ruta chalepensis, Lavandula stoechas, Salvia fruticosa, Mentha microphylla, Juniperus oxycedrus, Rosmarinus officinalis, Myrtus communis, Laurus nobilis and Ocimum gratissimum. Results show that essential oils isolated from F. vulgare, T. spicata, A. herba alba, O. syriacum and R. ...
2005-05-09
Fate of Mercury in Synthetic Gypsum Used for Wallboard Production
Energy Technology Data Exchange (ETDEWEB)
This report presents and discusses results from Task 5 of the study ''Fate of Mercury in Synthetic Gypsum Used for Wallboard Production,'' performed at a full-scale commercial wallboard plant. Synthetic gypsum produced by wet flue gas desulfurization (FGD) systems on coal-fired power plants is commonly used in the manufacture of wallboard. The FGD process is used to control the sulfur dioxide emissions which would result in acid rain if not controlled. This practice has long benefited the environment by recycling the FGD gypsum byproduct, which is becoming available in increasing quantities, decreasing the need to landfill this material, and increasing the sustainable design of the wallboard product. However, new concerns have arisen as recent mercury control strategies developed for power plants involve the capture of mercury in FGD systems. The objective of this study is to determine ...
2006-06-01
Energy Technology Data Exchange (ETDEWEB)
The article provides a 1998 updated picture of Italy's and the world's photovoltaic market in terms of produced modules and total installed capacity, as well as market growth forecasts up to 2010. After a short description of the state-of-the-art of cell and module manufacturing, ana analysis of the cost of producing a photovoltaic kw is reported for different plant types: stand-alone plants with energy storage batteries, plants connected to low low voltage networks or intended for supporting medium voltage networks, hybrid plants with diesel sets. The article is concluded by illustrating ENEL's (Electric Power Production Company) engagement in the field of photovoltaic solar energy as regards theoretical studies, research and testing of new technologies, and installing plants; over nearly twenty years of activity, ENEL has designed ...
1999-04-01
International Nuclear Information System (INIS)
Considerations for longevity of nuclear facilities and ease of decommissioning are of great importance for future nuclear power plants. To this end, a concept of an optimal structural concept for nuclear reactor buildings has been studied: the main feature of this concept is to utilize large-sized, light weight prefabricated members with ultrahigh strength materials. The following two items have been selected to study the prospective structure: (1) Applicability of ultrahigh strength materials for reinforced concrete shear walls (2) Construction using large sized prefabricated members As the first step (1), material and structural tests using ultrahigh strength materials, and the subsequent analysis of those tests for reinforced concrete shear walls, has been conducted. The positive results of this study show a bright future for the use of ultrahigh strength materials for the reinforced concrete shear walls of nuclear ...
1993-08-15
Energy Technology Data Exchange (ETDEWEB)
Heat exchangers for high and ultrahigh temperatures are a need and a precondition to realise high efficient fossil fired power plants based on the so-called Externally Fired Combined Cycle (EFCC) or the Indirect Fired Gas Turbines (IFGT). The main target of both processes is to increase the thermal efficiency of existing power plants by approximately 25% resulting in the same decrease in fuel consumption and, therefore, in the same reduction of CO{sub 2} formation. The main activities of the MPA University of Stuttgart in this project is focused on the characterisation and qualification of the structural material of the ultrahigh temperature heat exchanger (UHTHE) necessary in the above mentioned processes. The influence of the temperature and load on the material behaviour have been analysed by means of tensile tests and creep tests. The effectiveness of different coating systems and the interaction ...
2004-07-01
Energy Technology Data Exchange (ETDEWEB)
This report prepared for the Swiss Federal Office of Energy (SFOE) describes the practical realisation and testing of a heat recovery system based on a one-stage organic Rankine cycle with R134a as the working fluid. The waste heat has a temperature of 95 {sup o}C and originates from a gas engine that powers a small co-generation plant fuelled with biogas produced on-site. Two similar cycles have been built, ORC1 with one and ORC2 with two turbines. Only ORC1 has been tested so far. The maximum efficiency measured in these tests was 6.64% (theoretical Carnot-efficiency: 17 %) and the electric power output was 5.0 kW. The problems encountered during commissioning are described and recommendations for further improvements are given.
2005-07-01
Ionic liquids for post combustion CO{sub 2} absorption
Energy Technology Data Exchange (ETDEWEB)
The use of ionic liquids for post combustion capture was discussed. Compared to other solvents, ionic liquids can be used in higher concentrations. Other advantages include the large variation in physical and chemical properties and the non measurable vapor pressure. In this study, 78 different ionic liquids were synthesized and the carbon dioxide absorption rate was measured. The most promising ionic liquids were produced and various tests were made to identify the most suitable absorption solvent. The vapor-liquid equilibrium curve was measured between 40 and 110 degrees C. Pilot plant tests with MEA and one selected ionic liquid test with 30 per cent MEA at the pilot plant at the EVNs Duernrohr Power Station in Lower Austria are running successfully with a capture performance of approximately 87 per cent. The experiments will provide a direct comparison of the energy demand and ...
2009-07-01
FFTF operations: initial operator training simulator program
International Nuclear Information System (INIS)
This paper describes the Fast Flux Test Facility (FFTF) Operations initial training program utilizing the Operator Training Simulator (OTS). The OTS is a computer-driven system that provides real time response of essential FFTF plant functions to a control room mockup. The FFTF, a 400 Megawatt, three-loop, sodium-cooled fast test reactor will test fuels, materials and equipment for the U.S. Liquid Metal Fast Breeder Reactor Program. Construction is expected to be completed in August 1978. Initial criticality is expected in early 1979. This schedule will require FFTF control room operators to be fully qualified to operate the facility by late 1979. Because FFTF is like no other U.S. nuclear reactor, existing U.S. utility plants could not be depended on to provide highly experienced people to operate FFTF. Therefore, an Operator Training Simulator has been built. The OTS will play a ...
Development of a new evaporator using hydrophobic membrane for radioactive liquid waste
Energy Technology Data Exchange (ETDEWEB)
An evaporator using a hydrophobic membrane made from a polytetrafluoroethylene (PTFE) was developed to improve DF (Decontamination Factor) and to reduce evaporator size. The membrane distillation, provided by the evaporator, is a new technique for liquid purification. Fundamental experiments were carried out to develop the membrane filter (tube type, outer diameter, 8 mm; membrane thickness, 500 {mu}m) for radioactive liquid treatment. The continuous operation test using actual liquid waste was also made during about 3,000 h. (This is almost equal to the operation time of an actual evaporator per year.) The evaporation rate decreased with increase an operation time due to contamination of waste impurity. But the rate was recovered by washing the membrane with hot water and then drying it. DF was over 10{sup 4} which is ten times larger than that for a conventional system. A pilot plant (capacity, 200 kg-liquid waste/h) was constructed and its ...
1996-10-01
Some highlights of phase-C commissioning of Tarapur-4 the first to be synchronized 540 MWe PHWR
International Nuclear Information System (INIS)
Commissioning of a Pressurized heavy water reactor (PHWR) plant of NPCIL involves three phases viz phase-A which consist of pre-criticality activities such as hydro test, air hold test, no load test of motors etc., phase-B consist of criticality and post criticality physics experiments. The phase-C, which is considered the major phase, consist of initial power raise to about 10 % , TG rolling, synchronization, going to significant power in steps and performance tests such as load rejection tests from various power levels. In order to have smooth commissioning for the Phase-C, an integrated team consisting of engineers from various design and analysis groups of NPCIL headquarters was formed to participate along with site O and M engineers, closely observe and coordinate phase-C commissioning activities. During this commissioning some major events and observations ...
2006-11-13
Drop Test of the Candu Spent Fuel Storage Basket in MACSTOR/KN-400
International Nuclear Information System (INIS)
The MACSTOR/KN-400 of Wolsung power plant in Korea is a dry interim storage facilities. There are 400 long slender cylinders in MACSTOR/KN-400. In one cylinder, ten baskets where Candu spent fuels are loaded are stacked and stored. For this MACSTOR/KN-400 facilities, analyses and tests for the hypothetical accident conditions that might happen during moving and storing baskets into a cylinder were performed. The hypothetical accident conditions to be considered are two cases. One is the case of basket dropping onto the bottom plate of a cylinder. The other is the case of basket dropping onto the other basket top plate stored in the cylinder. For the drop analyses, the case of hanging cylinder and the case of cylinder on the unyielding target surface were considered. Based on the dropping analysis, testing condition was determined as the latter case that is for the cylinder on the target surface. In a basket, 60 dummy fuel ...
2009-06-01
Diagnosing mechanical changes: A test of the machine condition monitoring concept
Energy Technology Data Exchange (ETDEWEB)
BC Hydro recently conducted a demonstration test of a bearing condition monitor. The test, at the 529-MW Kootenay Canal project, proved the ability of the monitor to detect machine condition faults. The capability to detect changing conditions during normal operation of hydroelectric machines gives hydro plant owners the opportunity to anticipate needed maintenance and ultimately to reduce the number of equipment failures. BC Hydro intends to install bearing condition monitors, as well as windings monitors, brushgear monitors, environmental monitors, and other selected systems in as many as 46 of its hydro generators. BC Hydro analyzed forced outages between 1985 and 1989 in its hydro system to identify which parts of a generating unit resulted in the highest number of hours of outage. From there, the utility has formulated a concept for a machine condition monitoring system. To keep the system cost effective, it will be ...
1993-05-01
Energy Technology Data Exchange (ETDEWEB)
A common practice of electric utilities experiencing transmission and distribution (T and D) system overloads is to expand the substation, add lines, or upgrade equipment, all of which are capital intensive options. In 1988, it was hypothesized that strategically sited photovoltaics (PV) could benefit parts of T and D systems near or at overloaded conditions. An evaluation methodology was developed and applied to a test case (Kerman Substation near Fresno, California). Analytical results suggested that the value of PV to the T and D system could substantially exceed its energy and generation capacity value. The importance of this finding indicated the need for empirical validation. This led to the construction of a 0.5 MW PV demonstration plant by Pacific Gas and Electric Company (PG and E) at Kerman, California as part of the PVUSA (PV for Utility Scale Applications) project. PVUSA is a national public-private partnership that is assessing and ...
1994-07-01
Ultra fine grinding of low-rank coal. Progress report, April-June 1986
Energy Technology Data Exchange (ETDEWEB)
The lignite used for Phase I of the project was a Texas lignite from the Martin Lake mine obtained from the stockpile for the Martin Lake Power Plant of the Texas Utilities Generating Company. The power requirements for the fluid-energy mill were determined from the measured steam (or air) temperatures, pressures and pressure drops and the lignite flow rate. The instrument locations for the tests are shown on Figure 1. All of the instruments were connected to a microcomputer via an analog input interface board. Data were recorded on disks periodically throughout the tests. Appropriate calibration procedures were followed to assure that reliable data were being obtained. The combined grinding/drying tests were conducted in Vicksbuth, MS at Ergon, Inc.'s fluid-energy-mill facility. both steam and air were used as grinding fluids. With steam, tests were used as grinding ...
1986-07-01
Geothermal heat cycle research: Supercritical cycle with horizontal counterflow condenser
Energy Technology Data Exchange (ETDEWEB)
The Heat Cycle Research Program, which is being conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. To meet this objective, the program has as one of its goals to improve the performance of geothermal binary cycles to levels approaching the practicable thermodynamic maximum. In pursuit of this goal, tests are being conducted at the Heat Cycle Research Facility located at the DOE Geothermal Test Facility, East Mesa, California. The current testing involves the investigation of binary power cycle performance utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation of the working fluid. In addition to the present test program, preparations are being made to investigate the binary cycle performance improvements ...
1987-01-01
The estimation of lifetime distribution of Alloy 800 steam generator tubing
Energy Technology Data Exchange (ETDEWEB)
Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...
2009-10-15
The estimation of lifetime distribution of Alloy 800 steam generator tubing
International Nuclear Information System (INIS)
Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...
2009-10-01
British Library Electronic Table of Contents (United Kingdom)
In the present work, quaternary chitosans as water-soluble compounds were prepared based on three-step process. Schiff bases were firstly synthesized by the reaction between the amino groups of chitosan with aliphatic aldehydes followed by a reduction with sodium borohydride (NaBH4) to form N-(alkyl) chitosans. N,N,N-(dimethyl alkyl) chitosans were then obtained by a reaction of chitosan containing N-butyl, N-pentyl, N-hexyl, N-heptyl, and N-octyl substituents with methyl iodide. The compounds were characterized using IR and NMR spectroscopy. Subsequent experiments were conducted to test their antimicrobial activities against the most economic plant pathogenic bacteria of crown gall disease Agrobacterium tumefaciens, soft mold disease Erwinia carotovora, fungi of grey mold Botrytis cinerea...
2010-01-01
Retinue of the beans roots growth by using neutron radiography technique
International Nuclear Information System (INIS)
Agricultural practices frequently cause the development of a soil compacted layer below the surface. These compacted layers restrict the root penetration into deeper layers of soil, in search for water. It is proposed to monitor, using Non Destructive Test, the roots growth due to the planting of standard seeds in different agricultural soils, in function of their compactness and humidity. It will be used the neutrons beams derived from an irradiation channel called J-9 of the Reactor Argonauta (IEN/CNEN), so that the neutron radiographic images of the soil-plant system can be obtained. Each root can be evaluated for its ability to penetrate into compacted soil layers; this fact would mean an optimization of agricultural harvests. (author)
2002-08-11
Recycling flow control device for a nuclear reactor
International Nuclear Information System (INIS)
Object: To permit a valve operation test to be periodically made during plant operation without causing variations in plant power by detecting flow control valve defect on the basis of a valve aperture alteration instruction. Structure: Step signals which are equal in absolute value and opposite in sign are coupled to the input side of flow controllers provided on the recycling loops of two or more recycling flow control systems. With these inputs the aperture of the flow control valve on one side is increased (or reduced) while the aperture of the valve on the other side is reduced (or increased). As a result, the recycling flow rate in the loop on one side is increased (or reduced) while that on the other side is reduced (or increased). Whether the valve is normally operating or not is confirmed by checking the recycling flow rate and valve aperture. (Nakamura, S.).
Invasion of coastal dunes by the alien shrub Rosa rugosa is associated with roads, tracks and houses
British Library Electronic Table of Contents (United Kingdom)
Mapping the distribution of invasive alien plant species is significant for testing ecological hypotheses and for guiding effective management. Little is known about the distribution of invasive plants at landscape scale, and the factors controlling their dispersal and establishment are still poorly understood. This is the case for Rosa rugosa, an invasive shrub with negative effects on biodiversity in dune ecosystems of NW Europe. The aim of the study was to identify the factors which determine the distribution of R. rugosa in coastal dunes. In a large semi-natural dune area of NW Denmark (2364ha) all patches of the species (1321, 1.3-59.1m2) were GPS mapped. Patch distribution was GIS analysed, based on aerial photographs and vegetation maps. The distance of R. rugosa from the most consp...
2009-01-01
Estimation and characterization of PCDD/Fs and dioxin-like PCBs from Chinese iron foundries
British Library Electronic Table of Contents (United Kingdom)
The iron foundry industry is considered to be a potential source of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). This study investigated the emission factors and total emission amounts of PCDD/Fs and dioxin-like polychlorinated biphenyls (DL-PCBs) from iron foundries in China. The concentrations and the World Health Organization toxicity equivalents (WHO-TEQs) are presented and the congener profiles are discussed in this paper. In the present work, 26 fly ash samples were collected and tested to quantify the PCDD/Fs and DL-PCBs generated by 14 plants of different scales, and five stack gas samples were collected from two (named as EFG and LFG) of those plants. The emission levels of PCDD/Fs and DL-PCBs indicated that hot-air cupolas had lower emissions than cold-air cupol...
2011-01-01
Empirical tests of life-history evolution theory using phylogenetic analysis of plant demography
British Library Electronic Table of Contents (United Kingdom)
Summary 1. A primary goal of evolutionary ecology is to understand factors selecting for the diversity of life histories. Life-history components, such as time-to-reproduction, adult survivorship and fecundity, might differ among species because of variation in direct and indirect benefits of these life histories in different environments or might have lower-than-expected variability because of phylogenetic constraints. Here, we present a phylogenetic examination of demography and life histories using a data base of 204 terrestrial plant species. 2. Overall, statistical models without phylogeny were preferred to models with phylogeny for vital rates and elasticities, suggesting that they lacked phylogenetic signal and are evolutionarily labile. However, the effect of phylogeny was signific...
2010-01-01
Development of a greenhouse-type solar dryer for medicinal plants and herbs
Energy Technology Data Exchange (ETDEWEB)
The economy of medicinal plant production is burdened considerably by the energy costs of drying. To substitute fossil energy, a solar heated dryer was developed, taking a plastic film greenhouse as superstructure to lower the initial costs. The solar air heaters, being incorporated into the roof, consist of a black absorber tissue, which is placed between the transparent cover of the greenhouse and an insulating air-bubble foil. To obtain a modular design, the system is structured along the ridge into segments of 2 m width. Each segment forms an independent solar air heater/batch dryer unit and is operated by a fan with a power consumption of 500 W. A prototype was tested in Yugoslavia, drying mint, sage and hops. (author).
1989-01-01
Development and Reproduction of grape phylloxera on irradiated in vitro cultured rootstocks
International Nuclear Information System (INIS)
The ability of a local strain of grape phylloxera to develop and reproduce on irradiated in vitro cultured rootstocks (Ru140, R99 and 3309C and one local variety 'Helwani' was determined. The results showed that there was great variation in developmental time and reproduction of phylloxera between irradiated and unirradiated in vitro cultured plants. Survival, number of eggs and mean developmental time were greatly reduced when phylloxera was reared on irradiated rootstocks. Based on the examined biological parameters of phylloxera, all tested rootstocks would be more resistant toward such destructive insect when they were irradiated. Thus, phylloxera resistance was enhanced when in vitro cultured plants were treated with low doses of gamma irradiation. (author)
British Library Electronic Table of Contents (United Kingdom)
In order to replace copper fungicides in organic potato production, 53 copper-free preparations (CFPs) based on natural compounds, including plant extracts and microorganisms, and five copper preparations were evaluated for their potential to control Phytophthora infestans, the pathogen that causes late blight of potatoes. In in vitro assays, 30% of the CFPs inhibited indirect germination of sporangia, 26% mycelial growth and in growth chamber experiments, 21% efficiently reduced foliar blight of tomato plants. In micro-plot field trials with applications twice a week, the copper preparations were the most effective and reduced foliar blight by 99%. Of the CFPs tested, Oekofluid P, Mycosin and other sulphuric clays, and C-2000 reduced late blight the most, from 63% to 37%. In small-plot tr...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
The research project aimed at the selection or development of wear-reducing measures for submerged components of hydroelectric power plants. This comprised the optimisation of hydraulic profiles as well as materials testing for abrasion and cavitation. Another field of research was the development of appropriate application processes. (orig.) [German] Das Hauptziel des Forschungsvorhabens bestand in der Auswahl bzw. Entwicklung geeigneter Schutzmassnahmen zur Verschleissminderung an wasserberuehrten Komponenten von Wasserkraftanlagen. Diesem Ziel untergeordnet waren neben der Optimierung hydraulischer Profile auch Materialuntersuchungen hinsichtlich Verschleissbestaendigkeit gegenueber Abrasion und Kavitation. Ebenso war die Entwicklung geeigneter Applikationsprozesse ein wichtiger Bestandteil der Aufgabenstellung. (orig.)
2002-07-01
International Nuclear Information System (INIS)
the Life table of local strain of grape phylloxera was determined to evaluate the relationship between indole acetic acid (IAA) and phylloxera on our local variety Helwani. The study was carried out by applying in vitro dual culture system. The results showed that there was a great variation in mean developmental time, female longevity, number of laid eggs and egg distribution between all IAA concentrations and plant ages. Based on the tested biological parameters of phylloxera, (Helwani) would be unsuitable host for such destructive insect as it became older and when 2mg/1 of IAA was applied to in vitro culture media. (author)
Energy Technology Data Exchange (ETDEWEB)
Among the items of the Sunshine Project in fiscal 1981 for development of a solvent extraction and liquefaction plant, this paper describes the achievements in developing secondary hydrogenation. A small continuous hydrogenation device equipped with three reaction columns that can be filled with catalyst of 50 cc, and a dedicated testing room were designed, and orders were placed with manufacturers. The fabrication, assembly, delivery, installation, piping and wiring were all completed. The device passed a completion inspection based on the high-pressure gas safety assurance law in December 1981. After leakage due to gas and material oil was checked, a trial operation was performed, and verified of normal operation. A screening test was carried out on three kinds of commercially available and prototype catalysts before testing the SRC containing material for studying the secondary hydrogenation. The ...
1982-03-01
Tests with cleaned and uncleaned gas on a pilot plant. Final report
Energy Technology Data Exchange (ETDEWEB)
The possibilities for heat recovery in a cast iron melting furnace were studied. A cupola furnace which produces 40 tonnes steel per hour, produces 25,000 Nm/sup 3//h of flue gases which contain 16-22% CO. Taking into account the heat losses at the chimney where fumes are cooled to 200/sup 0/C the recoverable heat is about 12.4-10/sup 6/ kcal/h which mainly consists of combustion heat in CO. This study showed that the heat can be used for the production of electricity, which will be used in the plant. Recovery of 87 kWh of electricity per tonne of steel produced is possible. A steam turbine driven generator of 3.5 MW will be required. The combustion of the low calorific gas (approximately 400 kcal/Nm/sup 3/) has been studied and gave positive results: wet CO gas can be burnt without addition of methane and preheating of air is not required. The pilot plant consisting of a thermic system (combustion chamber and equipment to produce and condense ...
1986-01-01
DEVELOPMENT OF TECHNOLOGIES AND ANALYTICAL CAPABILITIES FOR VISION 21 ENERGY PLANTS
Energy Technology Data Exchange (ETDEWEB)
The goal of this DOE Vision-21 project work scope is to develop an integrated suite of software tools that can be used to simulate and visualize advanced plant concepts. Existing process simulation software does not meet the DOE's objective of ''virtual simulation'' which is needed to evaluate complex cycles. The overall intent of the DOE is to improve predictive tools for cycle analysis, and to improve the component models that are used in turn to simulate the cycle. Advanced component models are available; however, a generic coupling capability that will link the advanced component models to the cycle simulation software remains to be developed. In the current project, the coupling of the cycle analysis and cycle component simulation software will be based on an existing suite of programs. The challenge is to develop a general-purpose software and communications link between the cycle analysis software Aspen ...
2002-08-31
[Pilot-plant testing for flue gas desulfurization and dust removal by activated coke].
A developed flue gas desulfurization and dust removal process with a cross-flow moving bed filled with activated coke (AC) was tested on a pilot scale with the gas treatment capacity of 1000 mg x h(-t). The results show that a easy-operating and stable-running pilot-scale testing equipment can be reached, and under the conditions of testing space velocity, the feed gas temperature of 120 degrees C, SO2 concentrations of 3232-6006 mg x m(-3) and dust concentration of 89.3-1599.7 mg x m(-3), the high efficiency of flue gas desulfurization and dust removal is reached with the purity of dust less than 50 mg x m(-3). In the technology, the spent AC was regenerated by heating, and the SO2 concentration in the desorption gas is about 40.1%, which can be efficiently recovered as a sulfur resource. Favorable economy benefit can be reached by using the process. PMID:16850821
2006-05-01
WIS decontamination factor demonstration test with radioactive nuclides
Energy Technology Data Exchange (ETDEWEB)
A radioactive Waste Incineration System (WIS) with suspension combustion is noticed as effective volume reduction technology of low level radiactive wastes that are increasing every year. In order to demonstrate the decontamination efficiency of ceramic filter used on WIS, this test has been carried out with the test facilities as joint research of Central Research Institute of Electric Power Industry (CRIEPI) and Sumitomo Heavy Industries, Ltd. Miscellaneous combustible waste and power resin, to which 5 nuclides (Mn-54, Fe-59, Co-60, Zn-65, Cs-137) were added, were used as samples for incineration. As the result of the test, it was verified that Decontamination Factor (DF) of the single stage ceramic filter was usually kept over 10/sup 5/ for every nuclide, and from the results of above DF, over 10/sup 8/ is expected for real commercial plant as a total system. Therefore, it is realized that the ...
1987-04-01
WIS decontamination factor demonstration test with radioactive nuclides
International Nuclear Information System (INIS)
A radioactive Waste Incineration System (WIS) with suspension combustion is noticed as effective volume reduction technology of low level radiactive wastes that are increasing every year. In order to demonstrate the decontamination efficiency of ceramic filter used on WIS, this test has been carried out with the test facilities as joint research of Central Research Institute of Electric Power Industry (CRIEPI) and Sumitomo Heavy Industries, Ltd. Miscellaneous combustible waste and power resin, to which 5 nuclides (Mn-54, Fe-59, Co-60, Zn-65, Cs-137) were added, were used as samples for incineration. As the result of the test, it was verified that Decontamination Factor (DF) of the single stage ceramic filter was usually kept over 10"5 for every nuclide, and from the results of above DF, over 10"8 is expected for real commercial plant as a total system. Therefore, it is realized that the off-gas clean up ...
Verification and testing of the RTOS for safety-critical embedded systems
Energy Technology Data Exchange (ETDEWEB)
Development in Instrumentation and Control (I and C) technology provides more convenience and better performance, thus, adopted in many fields. To adopt newly developed technology, nuclear industry requires rigorous V and V procedure and tests to assure reliable operation. Adoption of digital system requires verification and testing of the OS for licensing. Commercial real-time operating system (RTOS) is targeted to apply to various, unpredictable needs, which makes it difficult to verify. For this reason, simple, application-oriented realtime OS is developed for the nuclear application. In this work, we show how to verify the developed RTOS at each development lifecycle. Commercial formal tool is used in specification and verification of the system. Based on the developed model, software in C language is automatically generated. Tests are performed for two purposes; one is to identify consistency between the verified model ...
2003-07-01
Verification and testing of the RTOS for safety-critical embedded systems
International Nuclear Information System (INIS)
Development in Instrumentation and Control (I and C) technology provides more convenience and better performance, thus, adopted in many fields. To adopt newly developed technology, nuclear industry requires rigorous V and V procedure and tests to assure reliable operation. Adoption of digital system requires verification and testing of the OS for licensing. Commercial real-time operating system (RTOS) is targeted to apply to various, unpredictable needs, which makes it difficult to verify. For this reason, simple, application-oriented realtime OS is developed for the nuclear application. In this work, we show how to verify the developed RTOS at each development lifecycle. Commercial formal tool is used in specification and verification of the system. Based on the developed model, software in C language is automatically generated. Tests are performed for two purposes; one is to identify consistency between the verified model ...
2003-05-29
Transient Critical Heat Flux tests on a rod bundle simulating Pressurized Water Reactors
International Nuclear Information System (INIS)
Transients induced in nuclear power plants from many sources result in one or more fluid conditions changing with time. Fluid conditions of pressure, inlet temperature, inlet flow, or even system power many change separately or in conjunction with each other. The result of the condition change may be one which induces departure from nucleate boiling. An experimental investigation of transient which were intended to achieve Critical Heat Flux was performed at the Heat Transfer Research Facility of Columbia University for Siemens Nuclear Power Corporation. The transients were set up to include broad ranges of flow and pressure conditions near the operating range of pressurized water reactors. Transient events were dominated by varying single conditions and measuring the response of the system and of the rod thermocouples. Because of coupling effects within the test loop, secondary conditions would also vary. In order to perform controlled ...
Weldability of high strength Ni-based alloy USC141 as boiler tube for 700 C USC plant
Energy Technology Data Exchange (ETDEWEB)
Recently the increase of steam temperature and pressure of power plant is required to enhance the thermal efficiency and reduce the CO{sub 2} emission. For the application to advanced USC (Ultra Super Critical) boiler with steam temperature around 700 C, the application of Ni-based alloy such as Alloy617 will be necessary. A new Ni-based alloy USC141 (20Cr-10Mo-2Ti-Al-bal.Ni) with excellent creep rupture strength and low thermal expansion has been developed by Hitachi Ltd. and Hitachi Metals Ltd. as the candidate material for 700 C USC turbine components. In present work, to investigate the possibility for boiler tube application of USC141, its weldability and high temperature strength properties were experimentally examined. The tested material as solution-treated condition shows higher creep rupture strength than that of Alloy617. GTAW (Gas Tungsten Arc Welding) trials of tubular specimen using NIMONIC263 filler wire were conducted ...
2007-07-01
Survey on Aging Deterioration of Safety Related Equipment in Operating Nuclear Power Plants
International Nuclear Information System (INIS)
As a basic research to consider aging deterioration of the operating nuclear power plant to seismic fragility analysis, aging deteriorations occurring safety related equipment of both Kori unit 1 and Wolsung unit 1, are investigated in this study. First of all, 378 and 152 safety related equipment are selected at Kori unit 1 and Wolsung unit 1 respectively. Seismic review team including seismic capability engineer, is organized and seismic walkdown is carried out using the nondestructive tests. As a results of seismic walkdown, crack is a typical aging deterioration which can reduce the seismic safety of safety related equipment and the other aging deteriorations such as concrete compressive strength, corrosion, and tightness of anchor bolt, have a much smaller influence than crack. In order to manage the aging deterioration data collected through the seismic walkdown in effective and systematic, EDS(Evaluation of Deteriorated System) DB is ...
1997-04-14
Survey on Aging Deterioration of Safety Related Equipment in Operating Nuclear Power Plants
Energy Technology Data Exchange (ETDEWEB)
As a basic research to consider aging deterioration of the operating nuclear power plant to seismic fragility analysis, aging deteriorations occurring safety related equipment of both Kori unit 1 and Wolsung unit 1, are investigated in this study. First of all, 378 and 152 safety related equipment are selected at Kori unit 1 and Wolsung unit 1 respectively. Seismic review team including seismic capability engineer, is organized and seismic walkdown is carried out using the nondestructive tests. As a results of seismic walkdown, crack is a typical aging deterioration which can reduce the seismic safety of safety related equipment and the other aging deteriorations such as concrete compressive strength, corrosion, and tightness of anchor bolt, have a much smaller influence than crack. In order to manage the aging deterioration data collected through the seismic walkdown in effective and systematic, EDS(Evaluation of Deteriorated System) DB is ...
2008-02-15
Relative toxicities of pure propylene and ethylene glycol and formulated deicers on plant species
Energy Technology Data Exchange (ETDEWEB)
Propylene and ethylene glycol deicers are commonly used at airports in the US and other countries to remove and retard the accumulation of snow and ice on aircraft. Deicers may not only enter water bodies without treatment, due to excessive storm-related flow, but also may expose terrestrial organisms to high concentrations through surface runoff. Most available toxicity data are for aquatic vertebrates and invertebrate species; this study examined effects on terrestrial and aquatic plants. Terrestrial plant species included both a monocot (rye grass, Lolium perenne) and a dicot (lettuce, Lactuca saliva). Aquatic species included a single cell alga (Selenastrum capricomutum), and an aquatic macrophyte (duckweed, Lemna minor). Glycol deicers were obtained in the formulated mixtures used on aircraft. Pure ethylene and propylene glycol were obtained from Sigma{reg_sign}. Parameters measured included germination, root and shoot length, survival, ...
1994-12-31
IGENPRO knowledge-based digital system for process transient diagnostics and management
Energy Technology Data Exchange (ETDEWEB)
Verification and validation issues have been perceived as important factors in the large scale deployment of knowledge-based digital systems for plant transient diagnostics and management. Research and development (R&D) is being performed on the IGENPRO package to resolve knowledge base issues. The IGENPRO approach is to structure the knowledge bases on generic thermal-hydraulic (T-H) first principles and not use the conventional event-basis structure. This allows for generic comprehensive knowledge, relatively small knowledge bases and above all the possibility of T-H system/plant independence. To demonstrate concept feasibility the knowledge structure has been implemented in the diagnostic module PRODIAG. Promising laboratory testing results have been obtained using data from the full scope Braidwood PWR operator training simulator. This knowledge structure is now being implemented in the transient management module ...
1997-12-31
Energy Technology Data Exchange (ETDEWEB)
In order to evaluate the effects of radioactivity on active vegetal substances, samples of Fennel (Foeniculum vulgare Miller., fructus), Guarana (Paulinia cupana, Kunth, semen), Gingko (gingko biloba, L., folium), and Kawa-Kawa (Piper methysticum G. Forst, rhizoma), were treated with scaling doses (0 to 25 KGy) of gamma radiation (Co{sup 60}). The 'blind test' methodology was used. The active substances from each sample were analysed by qualitative and quantitative methods after radiation. There were no significant differences seen between the control sample (0 KGy) and the irradiated samples. Microbe contamination was significantly reduced, about 10000 CFU/g, with the initial 5 KGy dose. It was concluded that gamma radiation can be used as an alternative procedure to reduce microbiologic contamination in medicinal plants. Before this procedure can be extended to other medicinal plants, more specific ...
2001-04-01
Experimental modelling of a pilot lignocellulosic pellets stove plant
Energy Technology Data Exchange (ETDEWEB)
Small-scale stoves, producing heat and hot water, are suited for domestic purposes. In order to optimise their efficiency when using lignocellulosic pellets, an important task is to do research on their real performance. The general behaviour depends on many operational factors (air flow and humidity, pressure, etc), dimension and pellet characteristics (moisture, size, raw material, density, friability, etc). In this paper, the first results and general performance of a 24 kW pellet fixed bed stove pilot plant are presented. The plant has been designed to study pellet combustion in the laboratory. The main targets are to reduce emissions of pollutants and to improve energy efficiency. Different situations can be simulated and tested due to its flexible design. Temperatures, pressures, flows and emissions are measured and analysed. An extensive study of different load conditions is presented through the application of both ...
2004-12-01
Effects of irradiation in medicinal and eatable herbs
International Nuclear Information System (INIS)
For ages, herbs have been used as medicine and food. Nowadays, the interest in phytotherapeutics is increasing as well as the consumer attention. Some biochemical compounds synthesized by plants as alkaloids, phenolics, flavonoids, essential oils, tannins and vitamins, influence the composition of these plant pharmacologicals, which may produce various reactions in the human body. The microbial contamination in these raw plant materials is common, and the radiation processing is one appropriate technique for the reduction of microorganism. In herbs used as food products, the changes in total #beta#-carotene and flavonoids upon the radiation treatment were tested. The powdered and dehydrated herbs were irradiated with "6"0Co gamma rays applying doses of 0, 10, 20 and 30 kGy. The botanical species investigated were rosemary (Rosmarinus officinalis Linne), watercress (Nasturtium officinale R. Br), ...
2002-03-01
Energy Technology Data Exchange (ETDEWEB)
It is desired that the data on past ground information are easily picked out and used effectively when construction of power facilities such as power plants is planned. For this purpose, a data base system that is available for survey planning and design business has been developed. This system is divided into subsystems for input, registration, and output, which all can be processed by the personal computers. It also has a retrieval function for maps such as area maps and power facility maps in addition to a retrieval function for characters. As output functions, the system has a function to extract ground information through maps of facilities and their peripheries, an output function for geological profiles and soil test results, and liquefaction analysis and design constant setting support functions. As instances, applications of this system to the thermal power plant location program and to the construction of ...
1994-09-05
Catalytic oxidation of the unburnt fuel for the efficient production of electric energy
Energy Technology Data Exchange (ETDEWEB)
Modern combined cycle power plants with natural gas as the only fuel reach efficiencies of up to 58% for electric power generation. Nevertheless the reserves of natural gas are more limited compared to the reserves of coal. Therefore possibilities should be investigated to use coal for such plants also. One concept, that combines the use of coal in a combined cycle application with high efficiencies is examined in this paper. According to this concept the exhaust gas of the gas turbine (vitiated air) is the combustion air for the pulverised coal combustion, that takes place in the bottoming steam generator. Due to the low oxygen content of the vitiated air the burnout of the coal may be incomplete. In order to avoid the incomplete combustion of the coal and the resulting decrease of the efficiency of the plant and possible emission problems, a catalyst, that converts carbon monoxide and unburnt carbon to carbon dioxide ...
1995-12-31
Biomonitoring for creosote and pentachlorophenol in nearby residents of a wood treatment plant
Energy Technology Data Exchange (ETDEWEB)
Contaminated wood treatment sites can result in adverse health effects to nearby residents. Environmental exposure can be estimated by measuring concentrations of pollutants in air, water, food, or wipe tests. This environmental exposure value can be used as a surrogate to estimate individual exposure. The objective of this study was to determine whether or not pentachlorophenol (PCP) could be found in potentially exposed residents and if the dioxin levels are consistent with PCP exposure. A further objective of the study was to determine whether or not PAH-DNA adducts could be found in the potentially exposed residents. We present results of biomonitoring studies in residents living near a wood treatment plant that used coal-derived creosote and PCP to process and treat wood for over 100 years. The plant was built in 1904 and used creosote and PCP. Creosote is a complex mixture that contains numerous polycyclic aromatic ...
2004-09-15
Abrasion wear studies with abrasives from brown coal beneficiation
Energy Technology Data Exchange (ETDEWEB)
This paper evaluates abrasive jet wear tests, carried out on the ZUK-3M abrasion apparatus according to the GOSF 23.201-78 industrial standard. As abrasive material, brown coal coke dust, brown coal dust, power plant fly ash and quartz sand (for the purpose of comparison) were employed. Seventeen types of materials were blasted with abrasive jets, including a selection of steels, glass, rubber, SYS-pur plastics, cast basalt, Kawenit and vitroceramics. The test apparatus produced abrasive jet velocities between 12 and 130 ms/SUP/-/SUP/1 at rotor revolutions of 1,000 to 10,000 min/SUP/-/SUP/1. Blasted material samples were arranged at angles between 15 and 90 degrees. Various tables and graphs present abrasivity results. These results were employed for technical modifications of dedusting equipment in briquetting and coking plants, which led to a threefold increase in service life of abrasion endangered ...
1983-01-01
The effects of different plant extracts on intestinal cestodes and on trematodes
British Library Electronic Table of Contents (United Kingdom)
In the present study, chloroform, aqueous, (polyethylene glycol/propylene carbonate) PEG/PC extracts were made from coconut, onion, garlic, fig, date tree, chicory, ananas, and cistrose. These extracts were tested in vivo and in vitro on their anthelmintic activity against cestodes (Hymenolepis diminuta, H. microstoma, Taenia taeniaeformis) and trematodes (Fasciola hepatica, Echinostoma caproni). In all in vitro tests, the target parasites died. It turned out that the treatment of mice and rats with a combination of onion and coconut extracts (with PEG/PC) eliminated all cestodes from their final hosts. In addition, the same composition was effective against the intestinal fluke E. caproni, but not against the liver fluke F. hepatica in the final host, while both worms were killed in vitro...
2011-01-01
The SOS-LUX-TOXICITY-Test on the International Space Station
British Library Electronic Table of Contents (United Kingdom)
For the safety of astronauts and to ensure the stability and integrity of the genome of microorganisms and plants used in bioregenerative life support systems, it is important to improve our knowledge of the combined action of (space) radiation and microgravity. The SOS-LUX-TOXICITY test, as part of the TRIPLE-LUX project (accepted for flight at Biolab in Columbus on the International Space Station, (ISS)), will provide an estimation of the health risk resulting from exposure of astronauts to the radiation environment of space in microgravity. The project will: (i) increase our knowledge of biological/health threatening action of space radiation and enzymatic DNA repair; (ii) uncover cellular mechanisms of synergistic interaction of microgravity and space radiation; (iii) provide specified...
2006-01-01
Safe design of mud ditches in briquetting factories
Energy Technology Data Exchange (ETDEWEB)
The authors study technological safety of installing a water spray pressure vessel between electrostatic deduster and coal sludge ducts. These sprays are in use elsewhere for steam generator ash removal. Dust ignition and explosion tests were carried out to examine flame and pressure wave propagation through the vessel into ducts. Water jet diameter, amount of water sprayed and coal dust removed were varied. Pressure waves exceeded 250 Pa. Test results show the vessel to be suitable for installation in briquetting plants due to its flame and explosion barrier effect and extermination of smoldering dust fires. The only disadvantage of the vessel is seen as its water and electric power consumption: about 8 m/sup 3//h of water and 1.5 kW/h of power per vessel serving dedusters of a 2,200 m/sup 2/ rotary brown coal dryer. (MOS).
1987-06-01
Research on pitting corrosion of steam generator heat transfer tubes based on acoustic emission
International Nuclear Information System (INIS)
Corrosion of steam generator heat transfer tubes (SGHTT) is one of the important problems which affect safety operation of nuclear power plants (NPP), and the hazard of pitting corrosion of heat transfer tubes is the most serious. With an acoustic emission device, the signals during a corrosion test on SGHTT were collected and analyzed, and the corrosion points in the tubes were located accurately. The results show that pitting corrosion of heat transfer tubes has passed through three periods in its development: expansion phase, stationary phase and rapid developing phase. The corrosion damage of HTT can be found earlier with acoustic emission than any other non-destructive testing methods. Acoustic emission can be used for on-line and real-time monitoring of the safety and operation of the steam generator and has therefore a great significance. (orig.)
2010-09-01
International Nuclear Information System (INIS)
This pilot project was carried out for the purpose of testing methods for active biological monitoring. It covered a period of three years (until September 1994), including two years of exposure. The measurements served to determine pollutant levels in plants used as animal fodder and dust-borne heavy metal concentrations in different sites and, on this basis, to obtain indirect information on human exposure. Among others, the pilot project investigated the suitability of Italian rye-grass as a biological indicator for aluminium, arsenic, cadmium, cobalt, chromium, copper, iron, mercury, magnesium, manganese, nickel, lead, platinum, antimony, titanium, and zinc. (orig./GL).
British Library Electronic Table of Contents (United Kingdom)
In this work, we report for the first time on the analysis of genetic diversity within a set of 36 Tunisian Opuntia ficus indica (L.) Mill. ecotypes using RAPD markers.Random decamer primers were screened to assess their ability to detect polymorphisms in this plant crop. Thirty-nine RAPD markers were revealed and used to survey the genetic diversity at the DNA level and to establish relationships.Consequently, considerable genetic diversity was detected and the UPGMA analysis permitted the discrimination of all the genotypes and enabled their sorting into thirteen groups. The accession `R Sbiba inerme' was significantly divergent from all tested genotypes. In addition, as shown by the clustering the tested genotypes did not significantly diverge, though originating from different localiti...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
Under 10CFR50 Appendix B, utilities have a commitment to establish and maintain material control programs to assure the safety and reliability of their power plants. The guidelines in this report discuss methods of establishing, maintaining, and extending the shelf life of limited life items. In addition, these guidelines establish justifiable shelf lives for a sample of 70 items and review the effects of environmental conditions. Moreover, the guidelines are consistent with utility qualification test documentation and provide for evaluation of items with expired shelf lives. These guidelines set precedent by indicating that the shelf life is greater than previously available for many items. This increase in shelf life has been established through natural and accelerated aging tests.
1992-05-01
FFTF [Fast Flux Test Facility] reactor shutdown system reliability reevaluation
International Nuclear Information System (INIS)
The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.
FFTF (Fast Flux Test Facility) reactor shutdown system reliability reevaluation
Energy Technology Data Exchange (ETDEWEB)
The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.
1986-07-01
Energy Technology Data Exchange (ETDEWEB)
In situ treatment has been proposed as a remediation alternative for surface water and groundwater contaminated with uranium and nitrate as a result of former waste disposal practices in the S-3 Ponds. Interceptor trenches containing reactive media have been proposed to treat groundwater, and constructed wetlands and/or algal mats are potential alternatives for treating surface water. This report presents the results from testing of ten different reactive media, and combinations of media, that are candidates for use in the proposed interceptor trenches to remove uranium and nitrate from groundwater. It also presents the results of testing and evaluation of algal mats and wetlands for removing uranium and nitrate from surface water.
1998-01-01
Effect of thermal cycling on the alloy 800/2.25 Cr-1 Mo steel joint
International Nuclear Information System (INIS)
The critical part of the trimetallic transition joint (type 304 stainless steel/Alloy 800/2.25 Cr-1 Mo steel), the Alloy 800/2.25 Cr-1 Mo steel joint welded with Inconel 182, was subjected to thermal cycling between room temperature and 873 K. The thermal cycling test procedure used produces accelerated failures in transition joints similar to those observed in steam generators of operating power plants. On thermal cycling, precipitation at the weld/ferritic steel interface decreased on post-weld heat treatment. This precipitation increased with increased prior ageing and applied stress. The results of these tests indicated a considerable improvement in performance of the trimetallic transition joint compared to the direct (bimetallic) transition joint. (orig.).
Development of ultrafiltration and adsorbents: October 1979-March 1980
Energy Technology Data Exchange (ETDEWEB)
Tests on a sample of trench water from the Maxey Flats burial ground effectively demonstrated the new Reverse Osmosis Pilot Plant. The effluent from the 50% salt-rejection membrane was decontaminated well enough with the exception of tritium to be discharged to the environment. The performance of the 97% salt-rejection membrane was superior to that of the 50% membrane. A breakthrough and capacity experiment was conducted with Durasil 10 on a simulated Three Mile Island solution. The maximum decontamination factor was extrapolated to be 10/sup 6/, which would reduce the cesium level of TMI water to below the discard limit. Capacity (1/DF = 0.5) was reached at 1260 column volumes. Several adsorbents were tested in the engineering columns for decontamination of cesium-bearing solutions. Under the conditions of the experiment, these adsorbents were ineffective in removing cesium from the solution.
1980-07-02
Development of sealing insulator for electric penetration assemblies
International Nuclear Information System (INIS)
Electrical penetration assemblies mounted on the containment wall are used to carry electrical power and signals from the equipment inside this containment (e.g. recirculation pumps, control rod position indications etc.) Todays BWR nuclear power plants apply epoxy resin sealed electric penetration. Contrariwise, the epoxy resin (organic sealant) was replaced with sodium barium glass (inorganic) by way of trial in search for a quality sealant. The glass sealant has been proved to have high temperature airtightness at 300 degC above from an evaluation test involving full-scale model parts. Environmental tests were conducted continuously as to heat cycle, vibration and LOCA etc. the specimens (module) of five types. They were made certain of conformity to the design requirements for boiling water operation. (author).
Design and testing of fixed-wing MAVs
British Library Electronic Table of Contents (United Kingdom)
Purpose - This study aims to design and test some fixed-wing micro aerial vehicles (MAV). Design/methodology/approach - The MAV wing planform in this study was designed based on previous results and the need to reduce the weight of the MAV. The MAV had a wing planform with a 6 percent Gottingen-329 camber airfoil, a 20 swept-back leading edge and a straight trailing edge. The fuselage was designed to contain a motor, an electronic control system and a video camera with a built-in transmitter. The battery was located outside the fuselage to trim the center of gravity and enable the battery to be changed easily when it has run out. Two exaggerated vertical stabilizers were installed to prevent the MAV from rolling. The materials, the power plant and the electronics used to fabricate the MAV ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
This final report for the Swiss Federal Office of Energy (SFOE) reports on work done in the area of gasification of biomass. The use of dung, manure and sewage sludge as sources of energy is described and discussed. Hydrothermal gasification is proposed as an alternative to conventional gas-phase processes. The aim of the project in this respect is discussed. Here, a catalytic process that demonstrates the gasification of wet biomass to synthetic natural gas (SNG) in a continuously operating plant on a laboratory scale is being looked at. Difficulties encountered in preliminary tests are discussed. Long-term catalyst stability and the installations for the demonstration of the process are discussed, and gasification tests with ethanol are commented on.
2007-09-15
Behaviour of the steam generators in the Belgian nuclear power plants
International Nuclear Information System (INIS)
After a brief review of the degradations occurring on tubes of Inconel 600 in steam generators of PWR power stations emphasis is put on the conditioning of the secondary water and more particularly on the condensate treatment in the units of Doel which work on heavily polluted brackish water. The important role of non-destructive testing and eddy-current testing is also pointed out, method developed by Laborelec. The operational experience shows that Belgian stations are nearly not concerned by the degradations mostly found in power stations in other countries which shows the efficiency of the conditioning of the secondary water. On the other hand, other problems have occurred, resulting from: damage caused by foreign objects; fouling of tube before commissioning, cracking of bends and at the limit of the dudgeoning and leaking plugs. (AF).
1986-04-15
The effect of flow velocity on pitting corrosion and stress corrosion cracking of reactor materials
International Nuclear Information System (INIS)
This paper describes two research programs which are currently underway in the author's laboratory to investigate the effect of fluid flow on the degradation of power plant materials in high temperature/high pressure aqueous environments. These programs include the design and operation of a controlled hydrodynamic corrosion testing apparatus that can be used to study the general and localized corrosion characteristics of alloys in simulated nuclear reactor environments, and a study of the effect of flow velocity on the stress corrosion cracking of ASTM A508 C1.2 steel and Type 304SS in simulated BWR heat transport fluids.
Testing of 12Kh18N10T tube steel samples tendency to intergranular corrosion
International Nuclear Information System (INIS)
Tendency of 12Kh18N10T steel tube samples to intergranular corrosion (IGC) is investigated by an express electrochemical method in the 10% solution of H_2SO_4+0.0025 g/l of KCNS. Tendency to IGC is mainly detected on the internal surface of tube samples. It is shown that the tendency to INC under plant conditions is caused by surface carburization under its incomplete purification from the graphite lubrication.
1993-01-01
Review of the Vortec soil remediation demonstration program
Energy Technology Data Exchange (ETDEWEB)
The DOE`s clean-up of its nuclear complex require the development of innovative technologies to convert soils contaminated by hazardous and/or radioactive wastes to forms which can be readily disposed in accordance with current waste disposal methods. The unique features of Votec CMS technology should make it particularly cost-effective process for the vitrification of soils, sediments, sludges, and mill tailings containing organic metallic and/or radioactive contaminants. This article describes the technology (Votec`s combustion and melting system), the results of testing, the demonstration plant system, and summarizes the future schedule and the equipment needed. 3 figs., 3 tabs.
1994-11-01
On the problem of blast furnace coke quality
The introduction of large blast furnaces, oxygen-enriched blast and natural gas firing means that the coke rate is determined mainly by the ability of the coke charge to loosen up the burden and ensure a high level of permeability. Coke strength is now of great importance to the steelmaker, alongside ash and sulphur contents. The article suggests that moisture still offers a useful negotiating base for furnace operators and suppliers. It is important to know the moisture content and a sampling procedure is recommended for determining the moisture desorption time. Such tests also indicate any relationship between different quenching plants and the product.
1982-10-01
GC-MS investigation and toxicological evaluation of alkaloids from Leptadenia pyrotechnica
British Library Electronic Table of Contents (United Kingdom)
GC-MS analysis of isolated alkaloids from aerial parts of Leptadenia pyrotechnica (Forsk.) Decne (Asclepiadaceae) was performed. Twenty-four alkaloids and six simple amines were detected for the first time in this plant. Almost all of the alkaloids belonged to pyridine, pyrrole, pyrazine, and indole types. The acute LC50 of the total alkaloids and alcohol extracts estimated by means of brine shrimp toxicity test were 63.09 and 11.89 ppm, respectively. The antitumor activities of these extracts, using potato disc screen, showed good activity represented by -33.6% and -49.3%, respectively.
2009-01-01
Fundamental investigation of duct/ESP phenomena. Final report
Energy Technology Data Exchange (ETDEWEB)
Radian Corporation was contracted to investigate duct injection and ESP phenomena in a 1.7 MW pilot plant constructed for this test program. This study was an attempt to resolve problems found in previous studies and answer remaining questions for the technology using an approach which concentrates on the fundamental mechanisms of the process. The goal of the study was to obtain a better understanding of the basic physical and chemical phenomena that control: (1) the desulfurization of flue gas by calcium-based reagent, and (2) the coupling of an existing ESP particulate collection device to the duct injection process. Process economics are being studied by others. (VC)
1991-10-21
Fundamental investigation of duct/ESP phenomena
Energy Technology Data Exchange (ETDEWEB)
Radian Corporation was contracted to investigate duct injection and ESP phenomena in a 1.7 MW pilot plant constructed for this test program. This study was an attempt to resolve problems found in previous studies and answer remaining questions for the technology using an approach which concentrates on the fundamental mechanisms of the process. The goal of the study was to obtain a better understanding of the basic physical and chemical phenomena that control: (1) the desulfurization of flue gas by calcium-based reagent, and (2) the coupling of an existing ESP particulate collection device to the duct injection process. Process economics are being studied by others. (VC)
1991-10-21
Fossil Energy Program. Progress report for April 1978
This report--the forty-fifth of a series--is a compendium of monthly progress reports for the ORNL research and development programs that are in support of the increased utilization of coal and other fossil fuel alternatives to oil and gas as sources of clean energy. The projects reported this month include those for coal conversion process development, materials engineering, alkali metal vapor topping cycles, a coal equipment test program, an AFB coal combustor for cogeneration (CCC), engineering and support studies, process and program assistance, evironmental assessment studies, magnetic beneficiation, and AFBC demonstration plant.
1978-06-01
FFTF shield and gamma ray measurements
Energy Technology Data Exchange (ETDEWEB)
Shield measurements and four cycles of operating experience have shown the design and construction of radiation shields for the Fast Flux Test Facility (FFTF) reactor and plant to be satisfactory. A number of minor shield deficiencies were found and corrected. Most of these were associated with interfaces between components, each of which was satisfactory by itself. Preliminary evaluation of the shield measurements indicates satisfactory agreement with design calculations. Operator doses to date have been quite small, especially when compared to light water reactor experience.
1984-08-01
Decontamination of building surface using clay suspension
Energy Technology Data Exchange (ETDEWEB)
The decontamination of the urban building surfaces, based on the covering of clay suspensions, has been studied. Contaminated samples for test purpose were prepared by application of radioactive solution which was extracted from the soil of 2 km zone of the Chernobyl Nuclear Power Plant(ChNPP). The cation converting conditions of clay suspensions were determined by the experiments of swelling and stability of the suspensions. According to the experimental results, the most effective clay suspension was the NH{sub 4}-type which had a 7.1 of decontamination factor(DF) on Cs and 4.5 of DF on total nuclides after 3 times covering on slate.
1994-07-01
Co-operation Equipment Qualification for Safety grade I and C Equipment between Russia and Korea
Energy Technology Data Exchange (ETDEWEB)
Equipment Qualification technology for I and C system on nuclear grade have been approved with accurate and safe for verifying and validation. It contributes to acknowledge of reliability and to review of user approval. Also it did not completely satisfied the requirement of Russia, it can be satisfied by bit of modification on design. It is expected to support the export of safety PLC to nuclear power plant. Proven EQ technology is required on the further markets of nuclear. Therefore, comparison test with foreign country is necessary to support the mutual accreditation of EQ for export of domestic products.
2007-06-15
Causes of denting. Volume 5. Contaminant threshold tests. Final report
Steam generators in PWR plants have been subject to denting corrosion as a result of nonprotective magnetite forming on the carbon steel support plate causing the voluminous corrosion product that eventually crimps (dents) the heat transfer tube at the support plate interface. This project was designed to determine the causes of denting and the usefulness of water chemistry changes meant to arrest denting. This volume of the final report describes laboratory research on the correlation of water chemistry, superheat, and oxygen ingress with denting in steam generators.
1983-12-01
Energy Technology Data Exchange (ETDEWEB)
A small scale biomass metal contacting experiment was performed to screen the optimal plant species for biosorption and bioaccumulation of cadmium, zinc, nickel, lead, and copper. Experiments were also conducted to test the ability of the biomass to lower the metal concentrations below the US Environmental Protection Agency surface water discharge criteria. The minimum residual concentration was 0.1 mg/L for zinc, 0.004 mg/L for lead, and about 0.01 mg/L for cadmium, nickel, and lead. Results indicate that water milfoil can be used for bioremoval of metals.
1995-12-31
Back-up for high voltage cable pressurizing system
Energy Technology Data Exchange (ETDEWEB)
A back-up system is provided for a pumping plant or a pressure reservoir system used to maintain insulating oil under pressure in high voltage submarine power cables which includes a gas driven membrane pump to insure a small outflow of oil at a rupture point in the power cable to prevent water from penetrating the cable. The proper operation of the membrane pump is insured by introducing degasified oil at the drive side of the pump during the stand-by and test modes of operation of the back-up system. 11 drawings.
1982-07-19
The utilization of non-destructive method for in-service inspections in nuclear power components
International Nuclear Information System (INIS)
To ensure safe and reliable power production nuclear power plants must be operated at high level. Non destructive in-service inspections are inseparable part of the effort. Non destructive in-service inspections are essential on the ground of degradation mechanisms existence in nuclear power components. Degradation processes are constituent of operation of each industrial installation including nuclear power plants. Mission of non-destructive testing is degradation detection, closer characterization of its parameters (dimensions) and to supply as much information as possible to nuclear power plant operator. Eddy current testing method can be assigned to surface - volumetric methods. Method enables inspection of electrically conductive materials. It is particularly suitable for inspection of non-ferromagnetic materials like austenitic stainless steel and brass. The method is used for ...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
The R and D were carried out of a detecting system for measurement of data on the bottom of geothermal well, data transmission and signal processing, and an analysis system for well drilling trajectory control and well assessment while geothermal well drilling based on the data obtained by the detecting system. The paper reported the results of the technology development in fiscal 1996. In the development of the detecting system, improvement/design were conducted on a mud pulse generator constituting sonde, well bottom signal processing equipment, mode switch and inclined information sensor, and the system equivalent to the actual one was manufactured to conduct a running test at high temperature/pressure. Moreover, a test to confirm heat resistance of electronic parts was made for further improvement in heat resistance of the sonde, in order to obtain the data. In the development of an analysis system, conducted were enhancement of operability ...
1997-03-01
Energy Technology Data Exchange (ETDEWEB)
A Vacuum Circuit Breaker demonstrated its ability to interrupt short circuits with faster than normal rates of rise of Transient Recovery Voltage (TRV) at levels greater than those produced by most transformer secondary faults. Two recent exploratory test programs evaluated the interrupting ability of a 15kV Vacuum Circuit Breaker containing interrupters of the rotating arc type with contacts made from a Chromium-Copper powder metal mixture. The interrupting conditions covered a wide range of currents from 10% to 130% of the 28kA rated short circuit current of the tested circuit breaker and a wide range of TRV rates of rise, including the relatively slow rate of rise, normally used in testing and found in most indoor circuit breaker applications; two faster rates of rise equaling and exceeding those found in a known power plant transformer secondary protection application; and the fastest rates of rise ...
1994-12-31
Wool-waste as organic nutrient source for container-grown plants
International Nuclear Information System (INIS)
A container experiment was conducted to test the hypothesis that uncomposted wool wastes could be used as nutrient source and growth medium constituent for container-grown plants. The treatments were: (1) rate of wool-waste application (0 or unamended control, 20, 40, 80, and 120 g of wool per 8-in. pot), (2) growth medium constituents [(2.1) wool plus perlite, (2.2) wool plus peat, and (2.3) wool plus peat plus perlite], and (3) plant species (basil and Swiss chard). A single addition of 20, 40, 80, or 120 g of wool-waste to Swiss chard (Beta vulgaris L.) and basil (Ocimum basilicum L.) in pots with growth medium provided four harvests of Swiss chard and five harvests of basil. Total basil yield from the five harvests was 1.6-5 times greater than the total yield from the unamended control, while total Swiss chard yield from the four harvests was 2-5 times greater relative to the respective unamended control. The addition ...
2009-07-01
Optimal capacity of the battery energy storage system in a power system
Energy Technology Data Exchange (ETDEWEB)
Due to the cyclical human life, utility loads appear to be cyclical too. During daytime when most factories are in operation, the electricity demand is very high. On the contrary, when most people are sleeping from midnight to daybreak, the electric load is very low, usually only half of the peak load amount. To meet this large gap between peak load and light load, utilities must idle many generation plants during light load period while operating all generation plants during peak load period no matter how expensive they are. This low utilization factor of generation plants and uneconomical operation have sparked utilities to invest in energy storage devices such as pumped storage plants, compressed air energy storage plants, battery energy storage systems (BES) and superconducting magnetic energy storage systems (SMES) etc. Among these, pumped storage is already commercialized and ...
1993-12-01
Energy Technology Data Exchange (ETDEWEB)
Early in 1988 RWE decided to overhaul the power station at Goldenberg. This was necessary due to the age of the plant, the obligation to supply heat and process steam and recent amendments of environmental legislation. After analysing demands and needs one developed a plant concept with a 290 t/h and a 400 t/h steam generator. Due to lack of space the decision was made in favour of a circulating atmospheric fluidised bed combustion instead of steam generators with pulverised lignite combustion as these steam generators take up much more space due to the legally required desulphurisation plants for gaseous emissions. Apart from generating steam RWE wishes to gain experience with this combustion technology and test it for suitability and use in large-scale plant. (orig./KO) [Deutsch] Aufgrund des fortgeschrittenen Alters, der aktuellen Umweltschutzgesetzgebung sowie bestehender ...
1995-12-31
Status of steam generators in Spain
International Nuclear Information System (INIS)
There are a total of nine operational nuclear plants in Spain totalling 7.350 MWe. These units produced 54.265 x 106 KWh in 1990, 36% of the total generation in Spain. Seven of these plants are of the PWR type. The first plant in operation was Jose Cabrera (ZORITA) in 1968, one loop Westinghouse plant with a model 24 Steam Generator. Due to the design margin and careful operation of the Steam Generator of this plant its performance have been very good, with only 5% tubes plugged after 23 years of operation. This is one of the few units in the world that remains in phosphate chemistry. During the period 1981-1985 a total of four units, two in Almaraz and two in Asco entered in operation. These three loop s Westinghouse units use model D-3 preheater Steam Generators. The poor design and manufacture of the Steam Generators of these units have caused a large number of problems: ...
1991-09-16
Use of boron waste as a fluxing agent in production of red mud brick
Energy Technology Data Exchange (ETDEWEB)
The study was directed towards determining the usability of clay and fine wastes (CW and FW) of boron from the concentrator plant in Kirka (Turkey) as a fluxing agent in production of red mud (RM) brick. Both laboratory studies on the characterization of materials and industrial-scale tests for production of bricks were carried out. CW and FW, which have similar chemical composition but include different types and amounts of oxides, were added in amounts of 5, 10 and 15wt% to RM, which consists of high amounts of Fe{sub 2}O{sub 3}, Al{sub 2}O{sub 3}, SiO{sub 2} and alkalies. Six different sets of samples have been produced and fired at 700, 800 and 900{sup o}C. Dry shrinkage of green body, bending and compressive strength, firing shrinkage, water absorption, frost resistance and harmful magnesia and lime tests on heat-treated bodies have been performed. The mineralogical and mechanical tests showed that ...
2006-12-15
International Nuclear Information System (INIS)
In the heat exchangers of power plants, scale deposition may occur, especially at the leading edge of contraction. The growth of scale can lead to an increase in pressure and cause oscillation of the water level. In our previous study, the dependence of flow on contraction geometry was analyzed numerically and empirically. It was shown that the contraction ratio of hydraulic diameter of the flow path contributed greatly to the difference in pressure drop and turbulent kinetic energy at the leading edge of the flow path. In this study, the effect of contraction geometry and flow rate on scale adhesion was studied in AVT chemistry at 270degC using a high-velocity scale-adhesion test loop. The differential pressure and the amount of scale deposited due to scale adhesion at the leading edge of the flow path increased more in a quatrefoil-type flow path than in drill-type flow path. The differential pressure and the amount of scale deposited also ...
1999-05-01
Energy Technology Data Exchange (ETDEWEB)
Three test instruments are being evaluated to determine the feasibility of using photoacoustic technology for measuring unburned carbon in fly ash. The first test instrument is a single microwave frequency system previously constructed to measure photoacoustic signals in an off-line configuration. A second off-line instrument was constructed based in part on lessons learned with the first instrument, but which also expands the capabilities of the first instrument. Improvements include a control loop to allow more constant microwave power output and an ability to operate over a range of microwave frequencies. The third instrument, the on-line version of the fly ash monitor, has been designed, constructed, and initial efficiency tests have been conducted on the monitor's electrical components. This quarter focused on improving the signal strength of the accelerometer by increasing the power level of the microwaves ...
2004-07-01
Improvement of leaching characteristics of TOC from condensate demineralizers
International Nuclear Information System (INIS)
Recent nuclear power plants require high purity water to protect nuclear reactors or steam generators from SCC and maintain in good condition. In this connection, it is especially important to minimize sulfate, which is a corrosive chemical originated from oxidative degradation of cation exchange resins during operation. Recently, uniform particle size (UPS) strong acid cation gel resin with 14% cross-linkage, which has excellent stability against oxidization, has been applied to several condensate purification systems. For further improvement of water quality, some methods for changing the configuration of condensate demineralizer's resin bed have been examined. For example, these methods correspond to anion under layer and cation over layer. We have tested these methods by cold column tests. Furthermore, we have developed the newly anion exchange resin having higher efficiency and capacity for absorbing leachables from ...
2009-10-01
International Nuclear Information System (INIS)
Steam Generator (SG) tubes in PWR plant are periodically inspected using eddy current testing (ECT) method. In Japan, bobbin coil type dual function probe is used for full length inspection, but the detectability for circumferential crack is very poor, and to improve detectability for circumferential crack and supplement regular ECT, various kinds of multi segment eddy current probes and multi transducer ultrasonic testing (UT) method have been developed. ECT probes are constructed of multiple surfaceriding special winding differential type coils and UT probe consists of 16 transducers which are spaced equally around the probe circumference for 360deg wall coverage. Both of those EC and UT probes are designed effective to detect circumferential crack. On the other hand, various kinds of laboratory induced circumferential cracks have been made and destroyed to prove the detectability of these probes. (author).
1991-08-01
Energy Technology Data Exchange (ETDEWEB)
Water and mud samples were collected from canals and rivers which were adjacent to outlets discharging warm water of 3 power plants in Berlin. Downstream samples from 1 bathing resort were also collected. Free living amoebae were isolated from 138 water and 69 mud samples. From these respectively 156 and 73 strains could be cultured and were administered intranasally to mice for pathogenicity tests. Two Acanthamoeba strains from water and 7 from mud could be reisolated from mouse brain and or lungs, although no pathological disorders could be observed. Five Naegleria strains were negative in mouse inoculation tests. Four Acanthamoeba strains which were positive in mice were cultured at + 45 degrees C; no cytopathogenic effects were observed in tissue cultures. Acanthamoeba infective for mice could also be isolated from samples at low water temperatures. Further investigations have to show, whether changes in virulence of ...
1982-05-01
Energy Technology Data Exchange (ETDEWEB)
One of the principal problems confronting the remediation of Bear Creek Valley is the cleanup of contaminated groundwater. The S-3 Site is one of the locations in the valley where groundwater is most contaminated, and contamination from the S-3 Site has also caused extensive contamination of downgradient groundwater. This groundwater plume, therefore, has a high priority in the Bear Creek Valley remedial process. Pumping and treating groundwater was identified early in the feasibility study as a likely remedial alternative for the S-3 Site groundwater plume. The hydrology and geochemistry of the plume are extremely complex. There is a high degree of uncertainty in the current understanding of how the aquifer will react physically and chemically to pumping, making evaluation of a pump-and-treat alternative impractical at the present time. Before a pump-and-treat alternative can be evaluated, its technical practicability, effectiveness, and projected cost must be determined. A long-term ...
1995-02-01
Characterization of spent fuel approved testing material--ATM-104
Energy Technology Data Exchange (ETDEWEB)
The characterization data obtained to date are described for Approved Testing Material 104 (ATM-104), which is spent fuel from Assembly DO47 of the Calvert Cliffs Nuclear Power Plant (Unit 1), a pressurized-water reactor. This report is one in a series being prepared by the Materials Characterization Center at Pacific Northwest Laboratory (PNL) on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well-characterized spent fuel for testing in the US Department of Energy Office of Civilian Radioactive Waste Management (OCRWM) Program. ATM-104 consists of 128 full-length irradiated fuel rods with rod-average burnups of about 42 MWd/kgM and expected fission gas release of about 1%. A variety of analyses were performed to investigate cladding characteristics, radionuclide inventory, and redistribution of fission products. Characterization data include (1) fabricated fuel design, irradiation ...
1991-12-01
Characterization of spent fuel approved testing material---ATM-105
Energy Technology Data Exchange (ETDEWEB)
The characterization data obtained to data are described for Approved Testing Material 105 (ATM-105), which is spent fuel from Bundles CZ346 and CZ348 of the Cooper Nuclear Power Plant, a boiling-water reactor. This report is one in a series being prepared by the Materials Characterization Center at Pacific Northwest Laboratory (PNL) on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well-characterized spent fuel for testing in the US Department of Energy Office of Civilian Radioactive Waste Management (OCRWM) Program. ATM-105 consists of 88 full-length irradiated fuel rods with rod-average burnups of about 2400 GJ/kgM (28 MWd/kgM) and expected fission gas release of about 1%. Characterization data include (1) descriptions of as-fabricated fuel design, irradiation history, and subsequent storage and handling; (2) isotopic gamma scans; (3) fission gas analyses; (4) ceramography of the ...
1991-12-01
Energy Technology Data Exchange (ETDEWEB)
Economics may one day dictate that it makes sense to replace oil or natural gas with coal in boilers that were originally designed to burn oil or gas. In recognition of this future possibility, Pittsburgh Energy Technical Center (PETC) has supported a program led by ABB Power Plant Laboratories in cooperation with the Energy and Fuels Research Center of Penn State University to develop the High Efficiency Advanced Coal Combustor (HEACC). The objective of the program is to demonstrate the technical and economic feasibility of retrofitting a gas/oil designed boiler to burn micronized coal. In support of the overall objective the following specific areas were targeted: a coal handling/preparation system that can meet the technical requirements for retrofitting microfine coal on a boiler designed for burning oil or natural gas; maintaining boiler thermal performance in accordance with specifications when burning oil or natural gas; maintaining NOx emissions at or below ...
1995-07-01
Picture tour of Sasol II coal liquefaction plant
Energy Technology Data Exchange (ETDEWEB)
This is a collection of photographs of the plant which is now almost completed.
1980-03-01
Human Issues in Manufacturing Technology
... qualified manufacturing employees. David Lichtinger, plant manager for Lord Corporation's aerospace products plant in ...
1992-09-01
Applied and fundamental aspects of plant cell, tissue, and organ culture
Applied and fundamental aspects of plant cell, tissue, and organ culture
1977-01-01
Energy Technology Data Exchange (ETDEWEB)
A high-temperature flow reactor and different technical plants were tested within the framework of this research project. Anthropogenic N{sub 2}O emissions form during secondary flue gas or waste gas purification as secondary emissions during denitrification and pollution abatement measures. N{sub 2}O forms as an intermediate product as NO is reduced to N{sub 2}. Under certain operating conditions N{sub 2}O is not decomposed completely. Different secondary flue gas purification measures, i.e. selective noncatalytic reduction (SNCR), selective catalytic reduction (SCR), and nonselective catalytic reduction (NSCR) were investigated testing several technical plants and the high-temperature flow reactor. (orig./EF) [Deutsch] Das Forschungsprojekt ``Messung der N{sub 2}O-Emissionen von Verbrennungsanlagen und Untersuchung von Moeglichkeiten zur Emissionsminderung`` wurde an einem ...
1994-12-01
Improvement of fuel performance in the Wolsung Nuclear Power Plant
International Nuclear Information System (INIS)
From the start of commercial operation in 1983 until the end of 1985, the Wolsung Nuclear Power Plant operated for about 800 effective full power days (EFPDs). During this relatively short operational period it experienced various problems but achieved high reliability in operation. Wolsung recorded economical fuel utilization, particularly in 1985, together with a 94.4% plant capacity factor; it also showed successful in-pile test results as part of a fuel localization project. The actual fuelling rate was 16.3 bundles per EFPD in 1985, i.e. a saving of about 11% compared with the design fuelling rate of 18.2 bundles per EFPD. Better fuel performance was achieved because minimum excess reactivity was maintained in the core, characteristics unique to the core were found and the spatial flux distribution was controlled. The average discharge fuel burnup in 1985 was 6993 MW#centre dot#d/t U, which was 8.5% more than the ...
1986-09-15
Energy Technology Data Exchange (ETDEWEB)
Probabilistic assessment methods can be used to identify specific plant vulnerabilities. Application of such methods can also facilitate selection among system design alternatives available for safety enhancements. The quality of assessment results is however strongly dependent on realistic and accurate input data for modelling of system component behaviour and failure modes during conditions to be assessed. Use of conservative input data may not lead to results providing guidance on safety upgrades. Adequate input data for probabilistic assessments seems to be lacking for at least failure modes of some electrical components when exposed to a fire. This report presents an attempt to improve the situation with respect to such input data. In order to take advantage of information in existing documentation of fire incident occurrences some of the lessons learned from the fire at Browns Ferry Nuclear Power Plant on March 22, 1975 are discussed in ...
2000-03-01
The thematic plant life assessment network (PLAN)
Energy Technology Data Exchange (ETDEWEB)
The Plant Life Assessment Network (PLAN) is a Brite Euram Type II Thematic Network, initiated by the European Commission to facilitate structured co-operation between all cost shared action projects already funded by the Commission which fall under this common technical theme. The projects involved address a multiplicity of problems associated with plant life assessment and are drawn from Brite-Euram, Standards, Measurement and Testing, Nuclear Fission Safety and Esprit EC programmes. The main aim of the Network is to initiate, maintain and monitor a fruitful co-operation process between completed, ongoing and future EC R and D projects, thereby promoting improved cross fertilization and enhanced industrial exploitation of R and D results. As the project is in its infancy, this presentation covers the background to the initiative in some detail. In particular two key aspects are highlighted, namely, the requirement of the ...
1998-12-31
Secondary system chemistry control and sludge management
International Nuclear Information System (INIS)
Since 1975 All Volatile Treatment (AVT) has been the preferred method for controlling the secondary system operating environment in Westinghouse PWR plants. However, since AVT provides no buffering action against corrodent species present in the water as trace contaminants, utilities have initiated programs which combine control of contaminant ingress with total steam generator sludge management. The earliest applications of boric acid, to control denting type corrosion, began in 1978 and have continued up to the present time. Boric Acid has also been added as an inhibitor for SCC/IGA type corrosion since 1985. There are now approximately 30 plants operating with boric acid or boric acid/morpholine chemistry in the secondary system, and a growing number of plants where morpholine is being used as an additive to maintain pH and reduce iron transport attributable to erosion/corrosion. The impact of these modifications in the ...
Product moisture after the centrifugation of coarse coal
Energy Technology Data Exchange (ETDEWEB)
The presence of water in export coals increases transport and handling costs. Coarse (+0.5 mm) coal constitutes the majority of the product, and small changes in its final moisture content will have a significant effect on overall product moisture. An on-line moisture monitor was installed on a product belt immediately after a coarse coal centrifuge to continuously measure the moisture content of the coal from a single centrifuge. Basic studies were also conducted with a laboratory centrifuge specifically designed to characterize various coarse coal samples in terms of their water retention capacity. The moisture of the coarse coal (typically 6 to 9%) was found to vary by at least 1% at a particular plant, and by a number of percentage points between plants. An empirical model has been developed which can explain about 80% of the moisture variation from the 25 samples investigated. The rank of the coals ranged from 0.7 to 1.65% mean ...
1998-12-31
Predictive maintenance plant assessment
Energy Technology Data Exchange (ETDEWEB)
Many electric power utilities are currently employing machine condition monitoring technologies as a means of reducing forced outages and controlling repair costs. These condition monitoring technologies are a set of {open_quotes}tools{close_quotes} to help maintenance and operations personnel identify and repair machinery problems before catastrophic failure occurs. In this way, the analysis of this data becomes a vital link in the daily operation of the plant. Machinery vibration analysis, machinery balancing and alignment, motor current testing, periodic thermography surveys, analysis of lubrication oil samples, performance monitoring, chemistry monitoring, ultrasonic leak detection surveys, and non-destructive inspections are some of the technologies available to perform this condition monitoring. However, even for a small or medium size plant, the sheer volume of data provided by applying all or some of these ...
1996-07-01
Energy Technology Data Exchange (ETDEWEB)
The present project examined the operating characteristics and application possibilities of a new, compact combined heating and electricity generating unit with a thermal output of 14,5 kW and a generating capacity of 5,5 kW. Such a module was installed in a plant in Arlesheim (Canton of Basel-Country) and subject to performance measurements. The small heating and generating plant is designed for cyclic operation (without heat storage) and is very compact and low in cost. The heating and generating unit conforms to all Swiss regulations relating to electrical installations and air pollution control. The NO{sub x} emissions of the unit (400 mg/m{sup 3} in steady state operation) are above the limits of LRV 92 (80 mg/m{sup 3}), but the regulation does not apply for units in this power range. The electricity generation costs are approximately CHF 0.16/kWh. It therefore makes sense to install the module in regions with average supply tariffs of at ...
1995-12-01
International Nuclear Information System (INIS)
Growing of PV for electricity generation is one of the highest in the field of the renewable energies and this tendency is expected to continue in the next years. Due to the various seasonal, hourly and daily changes in climate, it is relatively difficult to find a suitable analytic model for predicting the performance of a grid-connected photovoltaic (GCPV) plant. In this paper, an artificial neural network is used for modelling and predicting the power produced by a 20 kWp GCPV plant installed on the roof top of the municipality of Trieste (latitude 45 deg. 40'N, longitude 13 deg. 46'E), Italy. An experimental database of climate (irradiance and air temperature) and electrical (power delivered to the grid) data from January 29th to May 25th 2009 has been used. Two ANN models have been developed and implemented on experimental climate and electrical data. The first one is a multivariate model based on the solar irradiance and the air ...
2010-12-01
Gas turbine applications in the drying industry
Energy Technology Data Exchange (ETDEWEB)
The purpose of this report is to determine if it is feasible to utilize the hot exhaust gas discharged from gas turbines in direct applications. This report illustrates the technical feasibility and economic viability of using gas turbines in drying applications. The size of turbines in this investigation ranges from 2 MW to 10 MW. In addition, an implementation strategy has been developed to employ this new system. The method used to structure the scope of this undertaking is as follows: Step 1. Collecting information by contacting dryer manufacturer and companies drying different products. Information was also gathered by literature studies and the internet. Thomas register is a great tool when it comes to company and market searches. Step 2. Looking into if it is technically possible to use the exhaust gas directly into dryers. The parameters needed for these calculations were gathered in step 1, and some of the more important are temperature, mass flow, heat demand, and information ...
2000-07-01
Dating divergences in the Fungal Tree of Life: review and new analyses.
The collection of papers in this issue of Mycologia documents considerable improvements in taxon sampling and phylogenetic resolution regarding the Fungal Tree of Life. The new data will stimulate new attempts to date divergences and correlate events in fungal evolution with those of other organisms. Here, we review the history of dating fungal divergences by nucleic acid variation and then use a dataset of 50 genes for 25 selected fungi, plants and animals to investigate divergence times in kingdom Fungi. In particular, we test the choice of fossil calibration points on dating divergences in fungi. At the scale of our analysis, substitution rates varied without showing significant within-lineage correlation, so we used the Langley-Fitch method in the R8S package of computer programs to estimate node ages. Different calibration points had a dramatic effect on estimated divergence dates. The estimate for the age of the Ascomycota/Basidiomycota ...
Advances in human reliability analysis in Mexico
Energy Technology Data Exchange (ETDEWEB)
Human Reliability Analysis (HRA) is a very important part of Probabilistic Risk Analysis (PRA), and constant work is dedicated to improving methods, guidance and data in order to approach realism in the results as well as looking for ways to use these to reduce accident frequency at plants. Further, in order to advance in these areas, several HRA studies are being performed globally. Mexico has participated in the International HRA Empirical study with the objective of -benchmarking- HRA methods by comparing HRA predictions to actual crew performance in a simulator, as well as in the empirical study on a US nuclear power plant currently in progress. The focus of the first study was the development of an understanding of how methods are applied by various analysts, and characterize the methods for their capability to guide the analysts to identify potential human failures, and associated causes and performance shaping factors. The HRA ...
2010-10-15
Energy Technology Data Exchange (ETDEWEB)
Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams, Energy Systems, through Geraghty and Miller, Inc., conducted an initial dye-tracer study during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. Based on the results of the initial study, Energy Systems recommended to the Tennessee Department of Environment and Conservation (TDEC) in the 1990 Groundwater Quality Assessment Report (GWQAR) (HSW ...
1992-11-01
Transuranium-element-contaminated soil cleanup
International Nuclear Information System (INIS)
Johnston Atoll (JA) is a small (270-ha), but strategic, US possession in the Pacific Ocean, which was previously used in nuclear weapons testing. Nuclear devices were launched by missile for detonations at very high altitudes. In 1962, one missile failed on the launch pad and two failed overhead. The devices were destructed without nuclear yield, but transuranium (TRU) elements were dispersed. Cleanup was swift and incomplete. A 2-ha area was placed under radiological controls and restricted from use due to residual contamination. Planning was begun in 1983 for a total JA cleanup to provide additional (unrestricted) land to meet future requirements. A TRUe soil cleanup is programmed to begin at JA in 1988 utilizing a full-scale mining plant. The plant should be able to process all contaminated soil by 1992 and produce less than #approx# 2000 m"3 of concentrated waste. This cleanup will increase the amount of land available ...
1987-06-07
Energy Technology Data Exchange (ETDEWEB)
Long-term disposal and management of low and intermediate-level radioactive waste is a major project of the nuclear power industry. Therefore, the selection of an underground waste repository has to be a geologically and seismologically stable storage. Easy transportation and emplacement is essential. The Wolsung nuclear power plant (NPP) of unit no. 1/2/ 3/ 4, which is responsible for the future of the energy industry, has already been constructed at the Wolsung site and a New NPP has recently been created at the Sinwolsung site. Radioactive waste used in the plant facilities, has piled up increasingly every year, but it should be taken to be managed at long-term underground storage disposal facilities. The Wolsung site for radioactivity waste repository was known to be relatively stable through various geological surveys, earthquakes, groundwater, engineering testing and analysis, but still more research related to the ...
2010-05-15
International Nuclear Information System (INIS)
Long-term disposal and management of low and intermediate-level radioactive waste is a major project of the nuclear power industry. Therefore, the selection of an underground waste repository has to be a geologically and seismologically stable storage. Easy transportation and emplacement is essential. The Wolsung nuclear power plant (NPP) of unit no. 1/2/ 3/ 4, which is responsible for the future of the energy industry, has already been constructed at the Wolsung site and a New NPP has recently been created at the Sinwolsung site. Radioactive waste used in the plant facilities, has piled up increasingly every year, but it should be taken to be managed at long-term underground storage disposal facilities. The Wolsung site for radioactivity waste repository was known to be relatively stable through various geological surveys, earthquakes, groundwater, engineering testing and analysis, but still more research related to the ...
2010-05-01
Technical requirements for the ASME PRA standard for nuclear power plant applications
Energy Technology Data Exchange (ETDEWEB)
In 1998 the American Society of Mechanical Engineers (ASME) formed the Committee on Nuclear Risk Management (CNRM) and a Project Team to develop a standard on PRAs for use in risk informed applications. This ASME standard is being developed to help provide an adequate level of quality in PRAs that are being used to support ASME initiatives to risk informed in-service inspection (ISI) and in-service testing (IST) of nuclear power plant components. A related need supported by the industry and the U.S. Nuclear Regulatory Commission is to reduce the level of effort that is being expended in pilot applications of risk informed initiatives to address questions about the sufficiency of quality in the supporting PRA models. The purpose of this paper is to discuss the authors' views on some of the technical issues that were encountered in the effort to develop the ASME PRA standard. Draft 12 of this standard has been issued for comment, and is ...
2000-07-01
Technical requirements for the ASME PRA standard for nuclear power plant applications
International Nuclear Information System (INIS)
In 1998 the American Society of Mechanical Engineers (ASME) formed the Committee on Nuclear Risk Management (CNRM) and a Project Team to develop a standard on PRAs for use in risk informed applications. This ASME standard is being developed to help provide an adequate level of quality in PRAs that are being used to support ASME initiatives to risk informed in-service inspection (ISI) and in-service testing (IST) of nuclear power plant components. A related need supported by the industry and the U.S. Nuclear Regulatory Commission is to reduce the level of effort that is being expended in pilot applications of risk informed initiatives to address questions about the sufficiency of quality in the supporting PRA models. The purpose of this paper is to discuss the authors' views on some of the technical issues that were encountered in the effort to develop the ASME PRA standard. Draft 12 of this standard has been issued for comment, and is currently ...
Studies of Elymus mollis directed toward its use in revegetation of maritime tundra
Energy Technology Data Exchange (ETDEWEB)
Selection of suitable species, which will survive the severe environment of low light, cool temperatures, and high winds, poses serious problems to revegetation programs in the Aleutian Islands. Selection must be based on adaptability of plants to the extremes of the Aleutian climate and, as realized more recently, on lack of disruption of the natural ecosystem. This places the emphasis on use of native species in revegetation. Elymus mollis Trin., American dunegrass, a dominant of the Aleutian dune community, was studied to better understand its potential for use in reclamation work. As the species occupies both beach and inland sites, an emphasis was placed on documenting its wide latitude of habitat occurrence. Community composition, dispersal, growth response, ecotypic variation, and nutrient relations were studied at two beach sites and two inland sites on Adak Island in the central Aleutian Islands in the 1977 and 1978 growing seasons. ...
1980-03-01
Research and development of new coal based combined cycle power plant concept
Energy Technology Data Exchange (ETDEWEB)
Out of concern for the global environment, technologies for coal-fired combined cycle power generation are under development throughout the world today, aiming at highly efficient use of coal. Under these circumstances, the authors and others, with the intention of producing a coal-fired combined cycle power generation system with higher plant efficiency, lower construction cost, and higher reliability than conventional systems, proposed a new gasification combined cycle power generation system that differs from the conventional IGCC system. The authors studied system configuration and conducted elementary research necessary for implementing the system. This report deals with the basic concepts of the system and the results of basic studies carried out to realize of the concepts, including a study on alkali metal vapour concentration in relation to heat corrosion; the relation between gas de-dusting temperature and gas alkali metal vapour concentration; and basic ...
1997-12-31
Optimization of INCOLOY alloy 800 mechanical properties for various power plant requirements
International Nuclear Information System (INIS)
The AMSE Boiler Code development of design stresses and their optimization for alloys 800 and 800H for conventional and nuclear power plants have coincided with many successful trial installations of these grades of alloy 800. These trial installations, along with laboratory tests, have shown that alloy 800H can be used for long times with a retention of good mechanical properties, including ductility. While gamma prime can be formed, it soon loses its detrimental effect on ductility in service. Sensitization of the alloy also occurs but it, too, has a decreasing effect on corrosion resistance with time in service, especially at elevated temperatures. The authors discuss all of these aspects and conclude that alloy 800 perhaps with low carbon control in the annealed (1800 to 1950degF)(982 to 1066degC) condition gives the optimum combination of properties to 1050degF(566degC) and alloy 800H (.05 to .10%C) solution annealed at 2100 to 2200degF ...
International Nuclear Information System (INIS)
Topics related to aerospace power are discussed, taking into account trends and issues of military space power systems technology, space station power system advanced development, the application and use of nuclear power for future spacecraft, the current status of advanced solar array technology development, the application of a parabolic trough concentrator to space station power needs, life test results of the Intelsat-V nickel-cadmium battery, and metal hydride hydrogen storage in nickel hydrogen batteries. Other subjects explored are concerned with alternative fuels, biomass energy, biomedical power, coal gasification, electric power cycles, and electric propulsion. Attention is given to an advanced terrestrial vehicle electric propulsion systems assessment, fuel cells as electric propulsion power plants, a sinewave synthesis for high efficiency dc-ac conversion, steam desulfurization of coal, leadless transfer of energy into the body to ...
1985-08-18
Integrating preventive maintenance, predictive maintenance, and maintenance technical support
Energy Technology Data Exchange (ETDEWEB)
The fundamental tasks of the Oak Ridge Y-12 Plant maintenance operations are planning, scheduling, executing, postmaintenance testing, completing the maintenance job, and supporting these activities with administrative and technical assistance. The Department of Energy (DOE) ``Maintenance Management Program`` guidelines require that we use a graded approach for applying formality and documentation to these maintenance operations. The most-rigorous controls should be placed on maintaining the most-vital systems, structures, and components (SSCs). We must understand risk assessments in order to evaluate which SSCs are most vital. The product of this assessment process is a well-developed understanding of where to apply the most rigor, formality, and documentation. Once we have determined where, we must determine how to apply maintenance so as to mitigate risk. Fundamental to determining how to apply it is an understanding of the main difference ...
1992-08-06
Full autonomous monitoring tools inside nuclear reactor building
Energy Technology Data Exchange (ETDEWEB)
In this paper, we define, design and test a radiation tolerant autonomous monitoring tool for nuclear embedded applications. The goal of the instrumentation system was to record the values of some parameters such as dose, temperature or vibrations appearing inside the containment building of nuclear power plants. The knowledge of these parameters will be a good help for predictive maintenance of the power plant components. For the design of the monitoring tool, we rely on commercial-off-the-shelf (COTS) low power electronic components to use battery-supplied power. A large amount of components starting from discrete transistors or logic units to memories and micro-controllers was associated to define and design a prototype. We then confirm the environment conditions tolerance estimated to up to 2 kGy of total dose and 80 C for temperature by on-line irradiation experiments for individual components and functions and ...
2009-07-01
Fast Flux Test Facility (FFTF) standby plan
Energy Technology Data Exchange (ETDEWEB)
The FFTF Standby Plan, Revision 0, provides changes to the major elements and project baselines to maintain the FFTF plant in a standby condition and to continue washing sodium from irradiated reactor fuel. The Plan is consistent with the Memorandum of Decision approved by the Secretary of Energy on January 17, 1997, which directed that FFTF be maintained in a standby condition to permit the Department to make a decision on whether the facility should play a future role in the Department of Energy`s dual track tritium production strategy. This decision would be made in parallel with the intended December 1998 decision on the selection of the primary, long- term source of tritium. This also allows the Department to review the economic and technical feasibility of using the FFTF to produce isotopes for the medical community. Formal direction has been received from DOE-RL and Fluor 2020 Daniel Hanford to implement the FFTF standby decision. The objective of the Plan ...
1997-03-06
Energy Technology Data Exchange (ETDEWEB)
The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not have individual FEMPs. The remainder of the DOE-owned, PNNL-operated facilities are referred to as ...
1999-04-02
Effect of antioxidants on aging of nuclear plant cable insulation
International Nuclear Information System (INIS)
The effects of various antioxidants and antioxidant concentrations on the radiation and thermal stability of EPDM and XLPE polymers used for insulation of electric cable in nuclear power plants were measured. The objective was to determine if particular antioxidants could be identified as being especially effective for stabilization against radiation aging and combined thermal and radiation aging. Elongation to rupture was used as the measure of stability. Materials were irradiated to doses up to 2 MGy (200 Mrad) at a dose rate of 200 to 300 Gy/h in the Cobalt-60 Gamma Irradiation Facility at the University of Virginia. All of the antioxidants tested, which were known to provide excellent thermal stability, also provided good stability for radiation aging and combined thermal/radiation aging, although small differences between antioxidants were noted. No antioxidant or antioxidant combination was identified as being especially outstanding. ...
Energy Technology Data Exchange (ETDEWEB)
The demand for high-quality fibres and shives from hemp and flax as an alternative raw material for the automotive and building industry is increasing. Fibres are used primarily for composite reinforcement instead of synthetic fibres. Shives are used for animal bedding, but processing trials in wood industry for the production of low weight particle boards from shives are also very promising. Fibre producers require experience in cultivation and harvesting as well as modern processing technologies in order to supply flax fibres or shives at competitive prices under the changing conditions of international raw material markets. A complete processing line has been developed, installed and tested at the Leibniz Institute for Agricultural Engineering (ATB) to study all the processing stages of fibre production. The new ATB line can produce high quality fibres and shives from retted and unretted hemp, flax and oilseed flax straw without technical changes of the machine ...
2010-07-01
International Nuclear Information System (INIS)
In order to develop competitive and reliable nuclear power generation systems, development of innovative structural design methods is indispensable and risk-based design approach based on the assessment of failure probability is being developed. Fatigue is commonly considered as an important contributor to failure probability in many components of reactor systems and its assessment gives a large influence on total reliability of the plants. In order to assess its effect on the reliability, propagation of cracks needs to be evaluated as well as their initiation and pre-existence probability. As a part of new design approach, efforts are being taken to develop a simplified estimation method for fatigue crack growth under cyclic application of thermal and thermo-mechanical loading. A simplified estimation method of J-integral based on reference stress method and elastic follow-up factor was developed based on many finite element analyses and evaluation of crack growth ...
2005-05-01
Development of a best estimate auditing code for CANDU thermal hydraulic safety analysis
Energy Technology Data Exchange (ETDEWEB)
The main purpose of this study is to develop a thermal hydraulic auditing code for the CANDU reactor, modifying the model of existing PWR auditing tool , i.e. RELAP5/MOD3. This scope of project is a fourth step of the whole project, applying the RELAP5/MOD3/CANDU+ version for the real CANDU plant LOCA Analysis and D2O leakage incident. There are three main models under investigation, i.e. Moody critical flow model, flow regime model of horizontal CANDU bundle, and fuel element heatup model when the stratification occurs, especially when CANDU LOCA is tested. Also, for Wolsung unit 1 D2O leakage incident analysis, the plant behavior is predicted with the newly developed version for the first 1000 seconds after onset of the incident, with the main interest aiming for system pressure, level control system, and thermal hydraulic transient behavior of the secondary system. The model applied for this particular application ...
2001-03-01
Boron (B) is an essential plant micronutrient that is toxic at higher levels. NIP5;1 is a boric acid channel required for B uptake and growth under B deficiency. Accumulation of the NIP5;1 transcript is upregulated under B deficiency in Arabidopsis thaliana roots. To elucidate the mechanism of regulation, the 5' untranslated region (UTR) of NIP5;1 was tested for its ability to confer B-dependent regulation using ?-glucuronidase and green fluorescent protein as reporters. This analysis showed that the 5' UTR was involved in NIP5;1 transcript accumulation in response to B conditions. We also found that high-B conditions trigger NIP5;1 mRNA degradation and that the sequence from +182 to +200 bp in the 5' UTR is required for this mRNA destabilization. In the nip5;1-1 mutant background, a NIP5;1 complementation construct without the 5' UTR produced high levels of mRNA accumulation, increased B concentrations in tissues, and reduced growth under ...
2011-09-01
Application of hydraulic network analysis to motor operated butterfly valves in nuclear power plants
International Nuclear Information System (INIS)
This paper presents the application of hydraulic network analysis to evaluate the performance of butterfly valves in nuclear power plant applications. Required actuation torque for butterfly valves in high-flow applications is often dictated by peak dynamic torque. The peak dynamic torque, which occurs at some intermediate disc position, requires accurate evaluation of valve flow rate and pressure drop throughout the valve stroke. Valve flow rate and pressure drop are significantly affected by the valve flow characteristics and the hydraulic system characteristics, such as pumping capability, piping resistances, single and parallel flow paths, system hydrostatic pressure, and the location of the motor-operated valve (MOV) within the system. A hydraulic network analysis methodology that addresses the effect of these parameters on the MOV performance is presented. The methodology is based on well-established engineering principles. The application of this methodology ...
1992-07-01
Application of SGFM technology to alternate feedstocks. Phase III
Energy Technology Data Exchange (ETDEWEB)
The Synthesis Gas From Manure (SGFM) pilot plant was constructed at Texas Tech University to evaluate the gasification of cattle feedlot manure. A study of gas yield and composition as a function of operating conditions was performed. This report presents the results of a comparison of feedstocks other than manure in the pilot plant. Oak sawdust was the superior feedstock tested in terms of both gas yield and operability. Corn stover and mesquite were comparable and presented some handling problems. Cotton gin trash was unacceptable due to low-temperature ash fusion in the reactor. The gas yield from oak sawdust varied from 0.8 to 1.7 1/gm DAF feed at average temperatures of 650 to 770/sup 0/C. The gas contained approximately 15% hydrogen and 40% carbon monoxide by volume. It also contained 5 to 8% methane and 2 to 5% ethylene. All of these results were obtained using steam and air as the gasifying medium.
1980-01-01
Application and experience of low alloy steel main coolant lines in PWRs
Energy Technology Data Exchange (ETDEWEB)
The significant technical and industrial aspects which have led to main coolant line (MCL) materials selection are addressed from a long term experience and operational practice point of view. They are based on the Siemens/KWU developed basic material concept for its nuclear power plants. It considers the choice of appropriate materials, the evaluation and qualification of the materials and the materials manufacturer, the use of appropriate semi-finished products, the tailoring of material and semi-finished products to the specific requirements of the various systems, the application of adequate manufacturing processes and the proof of the requirements by specifying proper tests and examinations. The main systems are assigned to safety classes in accordance with their safety relevance. Summarizing the operation time of nuclear power plants with ferritic MCL equipped by Siemens/KWU, more than 200 years of operation ...
1996-08-01
/sup 252/Cf-source-driven neutron noise analysis method
Energy Technology Data Exchange (ETDEWEB)
The /sup 252/Cf-source-driven neutron noise analysis method has been tested in a wide variety of experiments that have indicated the broad range of applicability of the method. The neutron multiplication factor k/sub eff/ has been satisfactorily detemined for a variety of materials including uranium metal, light water reactor fuel pins, fissile solutions, fuel plates in water, and interacting cylinders. For a uranyl nitrate solution tank which is typical of a fuel processing or reprocessing plant, the k/sub eff/ values were satisfactorily determined for values between 0.92 and 0.5 using a simple point kinetics interpretation of the experimental data. The short measurement times, in several cases as low as 1 min, have shown that the development of this method can lead to a practical subcriticality monitor for many in-plant applications. The further development of the method will require experiments oriented toward particular ...
1985-01-01
Operational safety experience and passive safety testing at the FFTF
International Nuclear Information System (INIS)
The FFTF is a 400-MWt sodium-cooled fast neutron flux test reactor located on the US government-owned Hanford Site in southeastern Washington state. The reactor is operated for the US Department of Energy by the Westinghouse Hanford Company. Since FFTF started routine operation in 1982, the commercially fabricated driver fuel has performed flawlessly to well beyond the design goal peak burnup of 80 MWd/kgM. The core average discharge exposure is now some 60% beyond the original design expectations and attests to the ruggedness and reliability of the mixed oxide fuel system. In Cycle 9 sixteen long-life assemblies were installed to begin the irradiation of mixed oxides in the advanced low-swelling alloy HT-9 as the Core Demonstration Experiment (CDE). Operation of the plant from initial startup testing to ten cycles of operation has confirmed that the nuclear characteristics are well within the design predictions, and all ...
1987-10-21
Energy Technology Data Exchange (ETDEWEB)
Since the integrity of the containment penetrations was confirmed under accident management (AM) conditions in the former test, failure criteria tests and aerosol trapping tests were carried out using low-voltage modules and flange gaskets of an actual plant under severe accident (SA) conditions, without AM. The safety margin for failure temperature of the penetrations and the credit for fission product (FP) aerosol trapping effect along the leakage paths of the degraded penetrations were evaluated in the present tests. Failure temperature of the penetrations ranged from 270 to 300degC for low-voltage modules and 300 to 350degC for flange gaskets under 0.4 to 1.0 MPa conditions. Pressure dependency on failure temperature was small. This means that the safety margin of failure temperature under AM condition is more than 70degC. By introducing a equivalent leak area for the damaged ...
1999-07-01
ESBWR related passive decay heat removal tests in PANDA
International Nuclear Information System (INIS)
A number of test series to investigate passive safety systems for the next generation of Light Water Reactors have been performed in the PANDA multi-purpose facility at the Paul Scherrer Institut (PSI). The large scale thermal-hydraulic test facility allows to investigate LWR containment phenomena and system behaviour. PANDA was first used to examine the Passive Containment Cooling System (PCCS) for the Simplified Boiling Water Reactor (SBWR). In 1996 new test series were initiated; all related to projects of the EC Fourth Framework Programme on Nuclear Fission Safety. One of these projects (TEPSS) is focused on the European Simplified Boiling Water Reactor (ESBWR). The ESBWR containment features and PCCS long-term post LOCA response were investigated in PANDA. The PCCS start-up was demonstrated, the effect of nitrogen hidden somewhere in the drywell and released later in the transient was simulated and the effect of light ...
1999-04-19
On the impact of low power density microwaves in some living tissues
Energy Technology Data Exchange (ETDEWEB)
The biomedical and ecological interest for the microwave impact on the Earth biosphere is continuously increased since the industrial, military and communication activities strongly contribute to the electromagnetic stress of living bodies. In the next the authors present some of the main results obtained regarding the microwave exposure of various types of biological material: bacteria, fungi, young plant seedlings, dry seeds, animal tissues. The electromagnetic exposure was carried out in open space in well controlled environmental conditions by using 10.75 GHz/1 m W cm{sup -2} microwaves. Biochemical assays and cytogenetic tests have been carried out to reveal the changes induced post irradiation. The response of some pathogen bacteria, have been emphasized by means of turbidimetric measurements - the stimulatory effect being noticed at the level of the microbial population density (the stimulation of the human body microbial flora seems to ...
2006-07-01
CO2 Capture by Absorption with Potassium Carbonate
Energy Technology Data Exchange (ETDEWEB)
The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO3 promoted by piperazine (PZ). Pilot plant testing was performed in a 16.8-inch ID absorber and stripper with recirculation of air and CO{sub 2}. Three solvents (7 m MEA, 5 m K{sup +}/2.5 m PZ, and 6.4 m K{sup +}/1.6 m PZ) were tested in four campaigns with three different absorber packings. Pilot plant testing established that 5 m K{sup +}/2.5 m PZ requires two times less packing than 7 m MEA and three times less packing than 6.4 m K{sup +}/1.6 m PZ. A rigorous model of the thermodynamics and mass transfer was developed in the RateSep{trademark} block of AspenPlus{reg_sign}. The double matrix stripper reduces energy consumption by 5 to 15%. The best K{sup +}/PZ solvent, 4 m K{sup +}/4 m PZ, and the best process ...
2007-08-31
Energy Technology Data Exchange (ETDEWEB)
The Tennessee Valley Authority (TVA), the Electric Power Research Institute (EPRI), and the Department of Energy-National Energy Technologies Laboratory (DOE-NETL) are evaluating and demonstrating integration of terrestrial carbon sequestration techniques at a coal-fired electric power plant through the use of Flue Gas Desulfurization (FGD) system gypsum as a soil amendment and mulch, and coal fly ash pond process water for periodic irrigation. From January to March 2002, the Project Team initiated the construction of a 40 ha Carbon Capture and Water Emissions Treatment System (CCWESTRS) near TVA's Paradise Fossil Plant on marginally reclaimed surface coal mine lands in Kentucky. The CCWESTRS is growing commercial grade trees and cover crops and is expected to sequester 1.5-2.0 MT/ha carbon per year over a 20-year period. The concept could be used to meet a portion of the timber industry's needs while simultaneously ...
2005-08-30
GREENHOUSE GAS EMISSIONS CONTROL BY OXYGEN FIRING IN CIRCULATING FLUIDIZED BED BOILERS
Energy Technology Data Exchange (ETDEWEB)
Given that fossil fuel fired power plants are among the largest and most concentrated producers of CO{sub 2} emissions, recovery and sequestration of CO{sub 2} from the flue gas of such plants has been identified as one of the primary means for reducing anthropogenic CO{sub 2} emissions. In this study, ALSTOM Power Inc. (ALSTOM) has investigated several coal fired power plant configurations designed to capture CO{sub 2} from effluent gas streams for use or sequestration. Burning fossil fuels in mixtures of oxygen and recirculated flue gas (made principally of CO{sub 2}) essentially eliminates the presence of atmospheric nitrogen in the flue gas. The resulting flue gas is comprised primarily of CO{sub 2}. Oxygen firing in utility scale Pulverized Coal (PC) fired boilers has been shown to be a more economical method for CO{sub 2} capture than amine scrubbing (Bozzuto, et al., 2001). Additionally, oxygen firing in Circulating ...
2003-05-15
Metals and alloys : atmospheric corrosion testing : General requirements for field tests
Metals and alloys : atmospheric corrosion testing : General requirements for field tests
1992-01-01
British Library Electronic Table of Contents (United Kingdom)
Vermicompost preparations are increasingly used in agricultural practice. There is a possibility, that crop plants are sensitive to negative effect of vermicompost at early stages of development. The aim of the present study was to test the effects of vermicompost on seed germination and seedling growth of different vegetable crop species. Vermicompost substitution inhibited seed germination and seedling growth with almost linear decrease of growth with increasing concentration of vermicopost in the substrate. However, both leaf chlorophyll content and photochemical activity of photosynthesis increased in all crop species with the exception of pea seedlings. Vermicompost extract as a watering solution showed positive effect on growth of bean and pea seedlings. Germination response of vermi...
2011-01-01
Technology evaluation report for the Buried Waste Robotics Program Subsurface Mapping Project
International Nuclear Information System (INIS)
This document presents a summary of the work performed in support of the Buried Waste Robotics Program Subsurface Mapping Project. The project objective was to demonstrate the feasibility of remotely characterizing buried waste sites. To fulfill this objective, a remotely-operated vehicle, equipped with several sensors, was deployed at the Idaho National Engineering Laboratory. Descriptions of the equipment and areas involved in the project are included in this report. Additionally, this document provides data that was obtained during characterization operations at the Cold Test Pit and the Subsurface Disposal Area, both at the Idaho National Engineering Laboratory's Radioactive Waste Management Complex, and at the Idaho Chemical Processing Plant. The knowledge gained from the experience, that can be applied to the next generation remote-characterization system, is extensive and is presented in this report.
Energy Technology Data Exchange (ETDEWEB)
Studies the quality of metallurgical coke produced from a mixture of USA (80%) and Soviet (20%) coking coals. Properties of coal were analyzed according to ICCP and ISO international standards, including mechanical and petrographic tests. Content of the coal mixture included 8.2% moisture, 7.6% ash, 0.98% sulfur, 27.7% volatiles. The swelling index was 6 and dilation index 15%. Properties of coke produced from this coal mixture in the Croatian Bakar coking plant are presented for lump sizes of 25-80 mm, 10-25 mm and 0-10 mm. The produced coke was of favorable quality, having a strength index of 4.70, an ASTM stability factor of 61, and an M40 strength of 73.3%. 9 refs.
1990-01-01
Steam generator tube performance: experience with water-cooled nuclear power reactors during 1979
International Nuclear Information System (INIS)
The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).
1994-10-18
Safety philosophy and concepts for large liquid metal breeder reactor power plants
International Nuclear Information System (INIS)
This paper addresses the unique related aspects of the LMFBR concept which are of significance to containment design and structural analysis. Topics covered include: Primary boundary integrity assurance; Effects of sodium spills on integrity of structures; Provisions being considered for containment of melted cores; Fuel handling accidents. Specific reference is made to the FFTF and the Clinch River Breeder Reactor Project designs and methods of treatment of the above problems. In particular, the part played by tests, such as those carried out on a simulated FFTF model, and the planned structural reliability and related programs are considered. Where practicable, these topics are addressed in a manner which places FFTF and CRBR in context with other LMFBR's and point to a possible direction for future American LMFBR designs. (Auth.).
Safety philosophy and concepts for large liquid metal breeder reactor power plants
International Nuclear Information System (INIS)
This paper will adress the unique safety related aspects of the LMFBR concept which are of significance to containment design and structural analyses. Topics to be covered will include: primary boundary integrity assurance; effects of sodium spills on integrity of structures; provisions being considered for containment of melted cores; and fuel handling accidents. Specific reference will be made to the FFTF and the Clinch River Breeder Reactor Project designs and methods of treatment of the above problems. In particular, the part played by tests, such as those carried out on a simulated FFTF model, and the planned structural reliability and related programs will be considered. Where practicable, these topics will be addressed in a manner which places FFTF and CRBR in context with other LMFBR's, and will point to a possible direction for future American LMFBR designs.
1975-09-01
Research and development on next generation reactor (phase I)
Energy Technology Data Exchange (ETDEWEB)
The objective of the study is to improve the volume of nuclear power plant which adopts passive safety system concept. The passive safety system reactor is characterized by excellent safety and reliability. But the volume of NSSS (Nuclear Steam Supply System) of the passive safety system reactor is so small that it should be upgraded for commercial operation. For volume upgrade, detailed analyses are performed as follows; core design, hydraulics, design and mechnical structures, and safety analysis. In addition to above analysis, some investigations must be supplied as follows: power density vs. DNB margin decrease, outlet temperature vs. EPRI-URD, additional tests for upgraded reactor, dynamic analysis of mechanical vibration according to expanded reactor vessel and expanded in-core structures, and Merit loss of passive safety system reactor according to design margin decrease. (Author).
1994-10-01
RTA dual-fuel engine - natural gas instead of diesel oil
Energy Technology Data Exchange (ETDEWEB)
Test bed trials of the Sulzer RTA84 dual-fuel engine were successfully completed at the IHI Aioi engine works (Japan) in April 1986. This newly-developed engine-type, output range 15 to 40 MW, can be operated with both diesel or heavy oil and methane gas at comparable thermal efficiency and unchanged output. The RTA dual-fuel engine was developed in close collaboration between Sulzer Brothers Limited and its Japanese licenses. Intended for the propulsion of LNG carriers, where the boil-off gas from the ship's cargo is exploited for the generation of electricity in stationary plants, the RTA dual-fuel engines is an economic and reliable alternative to the steam or gas turbine. The performance of the engine is discussed.
1987-01-01
Production of plutonium, yttrium and strontium tracers for using in environmental research
International Nuclear Information System (INIS)
Summary of cyclotron production methods of "2"3"7Pu (45,2 d), "8"8Y (106,65 d) and "8"5Sr (64,84 d) tracers via nuclear reactions with protons and alphas on "2"3"5U, "8"8Sr and "8"5Rb targets in wide energy range is given. Chemical methods of separation and purification of the tracers from the irradiated uranium, strontium and rubidium targets are described. The tracers were used for determination of Pu (239-240), Sr-90 and Am-241 in the samples (soil, plants, underground waters) from Semipalatinsk Test Site. Obtained results are discussed.
2001-12-12
Preparation and applications of wood-polyester composites
International Nuclear Information System (INIS)
Optimum processing parameters were searched for the pilot-scale production of wood-polyester composites by irradiation of resin-impregnated wood material. The radiation initiation of the following systems were examined in wood and without wood matrix: methyl methacrylate, mixture of styrene and acrylonitryle, and their combination with unsaturated polyester. In the most cases the over-all rate of the complete polymerization process in wood matrix is proportional to the square root of the initiation rate. The parameters of the radiation technology of wood-polyester composites have been determined, using 260 TBq (7 kCi) "6"0Co radiation source. A pilot plant has been constructed using an underwater irradiation system of 1.85 PBq (50 kCi) "6"0Co. The successful production rate of 200 kg wood-polyester composite per day, as well as the application tests have demonstrated the technical feasibility of this new structural material. (author).
1982-01-01
Photobiology and photosynthesis
British Library Electronic Table of Contents (United Kingdom)
To test the hypothesis that leaf level photosynthetic related traits might confer late successionals a competitive advantage over early successionals in low light growth conditions, steady photosynthetic assimilation and dynamic photosynthetic induction related traits were examined in low light grown seedlings with contrasting successional status. Compared with the early successionals, late successionals as a group significantly exhibited lower leaf gas exchange rates. While late successionals required a longer time to respond to simulated sunflecks, they had lower rates of induction losses after sunflecks. Such photosynthetic induction traits allowed late successionals to more effectively utilize subsequent sunflecks. It was observed that plants with lower gas exchange rates responded mor...
2011-01-01
International Nuclear Information System (INIS)
Joint FAO/IAEA/WHO Expert Committee approved the use of radiation treatment of foods. Nowadays food packaging are mostly made of plastics, natural or synthetic, therefore effect of irradiation on these materials is crucial for packing engineering for food irradiation technology. By selecting the right polymer materials for food packaging it can be ensured that the critical elements of material and product performance are not compromised. When packaging materials are in contact with food at the time of irradiation that regulatory approvals sometimes apply. The review of the R-and-D and technical papers regarding material selection, testing and approval is presented in the report. The most information come from the USA where this subject is well elaborated, the International Atomic Energy Agency (IAEA) reports are reviewed as well. The report can be useful for scientists and food irradiation plants operators. (author)
PROSPECTS AND STATUS OF LOW-ASPECT-RATIO TOKAMAKS
Energy Technology Data Exchange (ETDEWEB)
The prospects for the low-aspect-ratio (A) tokamak to fulfill the requirements of viable fusion power plants are considered relative to the present status in data and modeling. Desirable physics and design features for an attractive Blanket Test Facility and power reactors are estimated for low-A tokamaks based on calculations improved with the latest data from small pioneering experiments. While these experiments have confirmed some of the recent predictions for low-A, they also identify the remaining issues that require verification before reliable projections can be made for these deuterium-tritium applications. The results show that the low-A regime of small size, modest field, and high current offers a path complementary to the standard and high A tokamaks in developing the full potential of fusion power.
1995-01-01
Numerical methods for thermal-hydraulics and structure in nuclear engineering
International Nuclear Information System (INIS)
Designs of nuclear reactor plants aim for high performance under safety consideration. Because of large scale and high pressure/temperature conditions, data from costly mockup tests have been required to verify simulation codes of systems and components. Establishment of design by analysis (DBA) in nuclear engineering is required for development of next generation nuclear reactors. Recent powerful computers and simulation technique enable numerical analyses to predict realistic behaviors of thermo-fluid flow, structure and do on. The present report describes resent simulation results of complex gas-liquid two-phase flow, large scale structure dynamics and fluid-structure interaction. (author)
2008-06-01
Nondestructive characterization of low-level transuranic waste
Energy Technology Data Exchange (ETDEWEB)
The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production waste characterization system.
1981-10-01
Non-catalytic and catalytic wet air oxidation of pharmaceuticals in ultra-pure and natural waters
British Library Electronic Table of Contents (United Kingdom)
A wet air oxidation (WAO) process was applied to four selected pharmaceuticals (metoprolol, naproxen, amoxicillin, and phenacetin) individually dissolved in ultra-pure water, varying the temperature and oxygen pressure. Due to the moderate (amoxicillin) or low (metoprolol, naproxen, and phenacetin) efficiency found in the oxidation of these pollutants, a catalytic wet air oxidation (CWAO) process was then tested using a platinum catalyst supported on multi-walled carbon nanotubes (CNT). In this CWAO process, the pharmaceuticals were dissolved together in ultra-pure water and in four natural water matrices-a reservoir water, a groundwater, and two waters from different municipal wastewater treatment plants. On the basis of the measurements of their removals, a discussion is given of the inf...
2011-01-01
New technology for purging the steam generators of nuclear power plants
British Library Electronic Table of Contents (United Kingdom)
A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D y 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is severa...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Work on the coke oven gas cleaning demonstration project (CCT-11) this quarter has focused on Phase IIB tasks, and include engineering, construction, and training. Additionally, plans for changes in the operating schedule of the coke plant that affect the demonstration project are described. The project Milestone Schedule and Log is shown. Planned Baseline Supplemental Monitoring activities described in the Environmental Monitoring Plan were completed. Testing of the mechanical systems began in June, 1991. The cold commissioning date has been moved back from October 1, 1991 to November 1, 1991 to allow float for miscellaneous finish-up items beyond the electrical contractor`s projected completion date of October 31, 1991.
1995-05-01
Energy Technology Data Exchange (ETDEWEB)
The renovation programme of the Phenix nuclear power plant (fast neutrons reactor situated at Marcoule) has for objective to ensure the reactor operation lengthening. In this frame, expertise and monitoring operation in situ of materials have been started. The presence of sodium and a temperature at the cold breakdown of the primary circuit between 150 and 180 degrees (Celsius) imply, for fast reactors, very special conditions. In this context, Framatome has realised three intervening in the area of nondestructive testing: the inspection of the cone-shaped support ring, the monitoring of the upper part of the primary vessel and the monitoring of the intermediary exchanger equipment. (N.C.)
2000-06-01
British Library Electronic Table of Contents (United Kingdom)
The cotton aphid, Aphis gossypii (Homoptera: Aphididae), is increasing in importance as a pest worldwide since the introduction of Bt-cotton, which controls lepidopteran but not homopteran pests. The chemical ecology of interactions between cotton, Gossypium hirsutum (Malvaceae), A. gossypii, and the predatory lacewing Chrysoperla lucasina (Neuroptera: Chrysopidae), was investigated with a view to providing new pest management strategies. Behavioral tests using a four-arm (Pettersson) olfactometer showed that alate A. gossypii spent significantly more time in the presence of odor from uninfested cotton seedlings compared to clean air, but significantly less time in the presence of odor from A. gossypii infested plants. A. gossypii also spent significantly more time in the presence of heads...
2011-01-01
Energy absorbers used against impact loading
International Nuclear Information System (INIS)
In the WWER-440 reactor the primary piping consists of six horizontal loops going radially from the pressure vessel, each loop having a horizontal steam generator. In this reactor type the relatively long primary piping with many curved sections requires special attention in order to successfully eliminate the consequences of the design basis accident. Emergency supports are located in appropriate places to restrict the movements of the pipe. Under normal conditions there is a gap of some centimeters between the pipe and a support so that in the pipe can be deformed freely under changing loads. This paper deals with those energy-absorbing structures used at the Loviisa Nuclear Power Plant for protection against impact loading. Places and circumstances where energy-absorbing structures are employed are specified. Development and design of impact absorber elements are discussed and impact tests are described. (Auth.).
1975-09-08
Energy Technology Data Exchange (ETDEWEB)
The performance of different polymers used to flocculate red mud particulate materials in the Bayer process can be evaluated on the basis of their efficiency to achieve adequate settling velocities and turbidity levels. In this study, three commercially available flocculants are evaluated under typical conditions found in the last washer of a Bayer plant. The different shear levels are produced by using a modified Couette flow system. Great differences are noticed in the performance of the polymers when they are compared at different dosages and at different shear rate levels. The data collected also suggests that conventional cylinder settling tests may not be adequate to measure the performance of certain types of polymers. (author)
2002-07-01
International Nuclear Information System (INIS)
The performance of different polymers used to flocculate red mud particulate materials in the Bayer process can be evaluated on the basis of their efficiency to achieve adequate settling velocities and turbidity levels. In this study, three commercially available flocculants are evaluated under typical conditions found in the last washer of a Bayer plant. The different shear levels are produced by using a modified Couette flow system. Great differences are noticed in the performance of the polymers when they are compared at different dosages and at different shear rate levels. The data collected also suggests that conventional cylinder settling tests may not be adequate to measure the performance of certain types of polymers. (author)
2002-08-11
Disruptive core relocation analysis of PHEBUS/FPT0 test with SAMPSON code
International Nuclear Information System (INIS)
SAMPSON is an integration of twelve analysis modules under the final development phase (phase-2) and will be capable of simulating hypothesized severe accidents in a nuclear power plant. One of these modules, the Molten Core Relocation Analysis (MCRA) module, simulates the relocation behavior of a molten core during a severe accident. MCRA models severe accident phenomena by using mechanistic formulations for multi-phase, multi-component, and multi-velocity field. As one of the verification studies of SAMPSON in Phase-1, the in-core phenomena of PHEBUS/FPT0 was analyzed with three modules, MCRA, fuel rod heat up analysis (FRHA) module, and the analysis control module (ACM) of SAMPSON. (author)
2000-10-01
Development of fluidized bed cement sintering technology
Energy Technology Data Exchange (ETDEWEB)
In the new system presented in this paper, the cement clinker is sintered, not in a rotary kiln, but in two different furnaces: a spouted bed kiln and a fluidized bed kiln. The heat generated in the process of cooling the cement clinker is recovered by a fluidized bed cooler and a packed bed cooler, which are more efficient than the conventional coolers. Compared with the rotary kiln system, the new technology significantly reduces NO{sub x} emissions, appreciably cuts energy consumption, and reduces CO{sub 2} emissions as well. Thus, the new system is an efficient cement sintering system that is friendly to the global environment. In this paper, we describe this new technology as one of the applied technologies at an industrial level that is being developed in the Clean Coal Technology Project, and we present the results from test operations at our pilot plant.
1994-12-31
Cost and sensitivity analysis for uranium in situ leach mining. Open file report Oct 79-Mar 81
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of an assessment of uranium in situ leach mining costs through the application of process engineering and discounted cash flow analysis procedures. A computerized costing technique was developed to facilitate rapid cost analyses. Applications of the cost model will generate mine life capital and operating costs as well as solve for economic production cost per pound U/sub 3/O/sub 8/. Conversely, rate of return may be determined subject to a known selling price. The data bases of the cost model were designed to reflect variations in Texas versus Wyoming site applications. The results of applying the model under numerous ore deposit, operating, well field, and extraction plant conditions for Texas and Wyoming are summarized in the report. Sensitivity analysis of changes in key project parameters have also been tested and are included.
1981-03-01
Common-Cause Failure Analysis for Reactor Protection System Reliability Studies
Energy Technology Data Exchange (ETDEWEB)
Analyses were performed of the safety-related performance of the reactor protection system (RPS) at U.S. Westinghouse and General Electric commercial reactors during the period 1984 through 1995. RPS operational data from these reactors were collected from the Nuclear Plant Reliability Data System (NPRDS) and Licensee Event Reports (LER). The common-cause failure (CCF) modeling in the fault trees developed for these studies and the analysis and use of common-cause failure data were sophisticated, state-of-the-art efforts. The overall CCF effort helped to test and expand the limits of the U.S. Nuclear Regulatory Commission's CCF methodology.
1999-08-01
Cause analysis and preventives for human error events in Daya Bay NPP
International Nuclear Information System (INIS)
Daya Bay Nuclear Power Plant is put into commercial operation in 1994 Until 1996, there are 368 human error events in operating and maintenance area, occupying 39% of total events. These events occurred mainly in the processes of maintenance, test equipment isolation and system on-line, in particular in refuelling and maintenance. The author analyses root causes for human errorievents, which are mainly operator omission or error procedure deficiency; procedure not followed; lack of training; communication failures; work management inadequacy. The protective measures and treatment principle for human error events are also discussed, and several examples applying them are given. Finally, it is put forward that key to prevent human error event lies in the coordination and management, person in charge of work, and good work habits of staffs.
Energy Technology Data Exchange (ETDEWEB)
Blowdown thrust forces and decompression characteristics were evaluated concerning the jet discharge or pipe whip tests with a 4-inch or 6-inch diameter pipe under PWR LOCA or BWR LOCA conditions related to pipe rupture accidents in nuclear power plants. This paper presents experimental evaluations of time-dependent and maximum blowdown thrust forces, and evaluations of decompression characteristics under instantaneous pipe rupture conditions. The following items are discussed: the peak value of the blowdown thrust force, the jet thrust coefficient for the maximum blowdown thrust force, the pressure recovery after break, and the relationship between the pressure undershoot of the sudden decompression and the decompression rate.
1984-06-01
Biomass power for rural development. Quarterly report, July 3--December 4, 1997
Energy Technology Data Exchange (ETDEWEB)
This paper describes progress in several projects related to biomass power. These include switchgrass conversion development; switchgrass gasification development; production activities including soil studies, carbon studies, switchgrass production economics, watershed impacts, and prairie lands bio-products; information and education; and geographical information system. Attachments describe switchgrass co-firing test; switchgrass production in Iowa; cooperative agreements with ISU; Rathbun Lake watershed project; newspaper articles and information publications; Secretary of Agriculture Glickman`s visit; integration of technical aspects of switchgrass production in Iowa; and evaluation of an integrated biomass gasification/fuel cell power plant.
1998-03-01
An assessment of health impacts of electrical power transmission lines
International Nuclear Information System (INIS)
The types of investigations undertaken to test for possible biological effects of extremely low frequency electric fields have been numerous. However, neither animal and plant experimentation nor clinical studies nor experience with operating extremely high voltage transmission lines have to date provided convincing evidence of a harmful effect from exposure to electric fields associated with transmission lines in spite of numerous attempts to find such effects. Analysis of internal fields and currents supports these observations as the levels appear to be too low to affect mammalian cells. Thus, while one can never prove the negative (i.e. that there is no effect), the overwhelming body of evidence indicates that the electric fields associated with high-voltage lines have no deleterious biological effects. (author).
1981-06-26
Active biomonitoring of heavy metal pollution using Rosa rugosa plants
British Library Electronic Table of Contents (United Kingdom)
The purpose of this work was to evaluate the quality of a rural area near Faenza (Italy) by using an active biomonitoring approach, i.e., by placing homogeneous individuals of the perennial shrub Rosa rugosa in different sites throughout the area. Further sites, within the city or its environs, were used for comparison. Soil and leaves of R. rugosa were analyzed for their heavy metal content. The total heavy metal pattern of leaves closely paralleled the pattern registered in soil, with the highest content (both in total and assimilable forms) at the site in the urban area, which is exposed to heavy traffic. Pollen quality (abortiveness and viability) was also tested as a potential indicator of pollution. Pollen abortiveness was strictly related to Pb levels in leaves, while viability was ...
2007-01-01
A study on the transient analysis of pipe and restraint due to impact loading
Energy Technology Data Exchange (ETDEWEB)
In this study, experiments were performed for pipe whip phenomena simulation. The analytical method was developed by combining several kinds of elements in ABAQUS computer code, standard version 5.2 . The transient analytical and the experimental results of the pipe whip test using 6 inch diameter pipe and U-shaped restraints are presented. It is shown that the adequate clearance decreases the restraint strains. As the overhang length increased, the maximum strain of restraints decreased. When the impact force increased, the maximum restraint strain increased slightly. The analytical models simulate the experimental impact phenomena very precisely, with slight conservatism. It is verified that the analytical method developed is very suitable to pipe whip phenomena analysis in nuclear power plants. 6 refs., 10 figs., 1 tab.
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
A controlled field pilot has been developed in Bozeman, Montana, USA, to study near surface CO2 transport and detection technologies. A slotted horizontal well divided into six zones was installed in the shallow subsurface. The scale and CO2 release rates were chosen to be relevant to developing monitoring strategies for geological carbon storage. The field site was characterized before injection, and CO2 transport and concentrations in saturated soil and the vadose zone were modeled. Controlled releases of CO2 from the horizontal well were performed in the summers of 2007 and 2008, and collaborators from six national labs, three universities, and the U.S. Geological Survey investigated movement of CO2 through the soil, water, plants, and air with a wide range of near surface detection techniques. An overview of these results will be presented.
2009-10-20
A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing
Energy Technology Data Exchange (ETDEWEB)
Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation on reliability of SG ...
2008-07-01
A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing
International Nuclear Information System (INIS)
Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation on reliability of SG ...
2008-06-01
The vigilance reinforcement hypothesis (VRH) asserts that errors in signal detection tasks are partially explained by operant reinforcement and extinction processes. VRH predictions were tested with a computerized baggage screening task. Our experiment evaluated the effects of signal schedule (extinction vs. variable interval 6 min) and visual field complexity (dial vs. baggage x-ray) on search behavior rates. There was a main effect for signal schedule [F (1, 20) = 14.0, p = 0.001, p[subscript rep] = 0.99], but no effects for field complexity or interaction. The VRH suggests that performance errors in visual screening work may be reduced through operant conditioning of search behaviors by intensive management of artificially planted signals. (Contains 1 table and 3 figures.)
2008-12-01
A Cross-National Analysis of How Economic Inequality Predicts Biodiversity Loss
British Library Electronic Table of Contents (United Kingdom)
Abstract: We used socioeconomic models that included economic inequality to predict biodiversity loss, measured as the proportion of threatened plant and vertebrate species, across 50 countries. Our main goal was to evaluate whether economic inequality, measured as the Gini index of income distribution, improved the explanatory power of our statistical models. We compared four models that included the following: only population density, economic footprint (i.e., the size of the economy relative to the country area), economic footprint and income inequality (Gini index), and an index of environmental governance. We also tested the environmental Kuznets curve hypothesis, but it was not supported by the data. Statistical comparisons of the models revealed that the model including both economi...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The following subjects were discussed at the conference: Stability of welded joints, creep stress in CrMo steels, life prediction, developments in modern power plant steels, testing, calculation of deformation, crack propagation and crack analysis under complex loads. [German] Die Autoren der Tagung referieren ueber folgende Themen: Stabilitaet von Schweissverbindungen, Kriechbeanspruchung von Chrom-Molybdaen Staehlen, Lebensdauervorhersage, Entwicklungen fuer die Anwendung in modernen Kraftwerken, Prueftechnik, Berechnung von Verformung, Rissentwicklung und -bewertung bei komplexer Beanspruchung. (uke)
2002-07-01
1-MW(th) solar-thermal conversion full-system experiment
Progress made during the first phase effort of the Solar-Thermal Full-System Experiment is summarized. This is one of a number of projects in the Solar-Thermal Subprogram involved with the development of solar central receiver hardware and systems for future use by utilities. The main emphasis is on systems that use Brayton-Cycle (gas turbine) equipment. The project summarized involves the planning and design of a complete Brayton-Cycle solar central receiver experimental system that would include all components of a commercial-size electric utility solar power plant. The objective of the overall project is to demonstrate the technical feasibility of a complete Brayton-Cycle, solar-fossil hybrid central receiver system. Major objectives of the Phase I effort summarized are to plan and design the experiment in detail and to organize a utility Test and Operating Group that would be directly involved in the development and operation of the ...
1982-08-01
Safe ageing management of nuclear power plants: An European synthesis
International Nuclear Information System (INIS)
Ageing of nuclear power plants means evolution of material or equipment properties on one side, and evolution of personnel skill and procedure adequacy on the other side, both of which, after a certain time, may not be compatible with the required safety provisions, or with an economic operation of the plant. Repair or replacement of components, as well as change in service conditions for a better compatibility with component reduced capabilities can be used to mitigate ageing effects. The paper summarises the results of a study conducted in this field with the support of the European Commission. It presents: the synthesis of the work done under international auspices, and in the European context; the comparison of ageing management approaches used in several European countries with international recommendations; the summary of the various potential phenomena and their governing parameters, the methods of in-service ageing identification and ...
2002-11-04
UK PubMed Central (United Kingdom)
The concept of plant intelligence, as proposed by Anthony Trewavas, has raised considerable discussion. However, plant intelligence remains loosely defined; often it is either perceived as practically...Full Text Available
2009-05-01
UK PubMed Central (United Kingdom)
BackgroundSenescence is integral to the flowering plant life-cycle. Senescence-like processes occur also in non-angiosperm land plants, algae and photosynthetic prokaryotes. Increasing...Full Text Available
Urinary tract infection: diabetic women's strategies for prevention.
Urinary tract infection (UTI) is a common problem in the female population. Women with diabetes mellitus are possibly at a higher risk. The usual medical therapy for UTI is antibiotic treatment. The aim of this study is to explore strategies employed by diabetic women for prevention and self-treatment of UTI. Forty-two women with diabetes mellitus who had experienced at least one episode of UTI in the last six months were included. Data collection included background information, questions about prevention and self-treatment strategies and a clinical examination to measure maximal urine flow, residual urine, a blood test evaluating diabetic control (HbA1c) and a urine test strip for determination of glucose, leucocytes, nitrite, blood, protein and pH. Thirty-five participants (83.3%) reported changes in daily routines like 'always keeping warm', 'increased fluid intake', 'good personal hygiene' as prevention strategies. Different herb and ...
Tritium tests with a technical PERMCAT for final clean-up of ITER exhaust gases
Energy Technology Data Exchange (ETDEWEB)
One of the design targets for the ITER Tokamak Exhaust Processing system is not to lose more than 10{sup -5} g h{sup -1} into the Normal Vent Detritiation System of the Tritium Plant. The plasma exhaust gas, therefore, needs to be processed in a way that an overall tritium removal efficiency of about 10{sup 8} is reached. Such a high decontamination factor can only be achieved by multistage processes. The third step of the three step CAPER process developed at the TLK is based on a so-called permeator catalyst (PERMCAT) reactor, a direct combination of a Pd/Ag permeation membrane and a catalyst bed. The PERMCAT principle is based on isotopic swamping in a counter current mode. Previous tritium experiments employing laboratory scale PERMCAT reactors have revealed decontamination factors as high as 10{sup 5} for the third CAPER step. First tritium tests with a technical scale PERMCAT reactor led to similar decontamination factors and clearly ...
2003-09-01
Tritium tests with a technical PERMCAT for final clean-up of ITER exhaust gases
International Nuclear Information System (INIS)
One of the design targets for the ITER Tokamak Exhaust Processing system is not to lose more than 10"-"5 g h"-"1 into the Normal Vent Detritiation System of the Tritium Plant. The plasma exhaust gas, therefore, needs to be processed in a way that an overall tritium removal efficiency of about 10"8 is reached. Such a high decontamination factor can only be achieved by multistage processes. The third step of the three step CAPER process developed at the TLK is based on a so-called permeator catalyst (PERMCAT) reactor, a direct combination of a Pd/Ag permeation membrane and a catalyst bed. The PERMCAT principle is based on isotopic swamping in a counter current mode. Previous tritium experiments employing laboratory scale PERMCAT reactors have revealed decontamination factors as high as 10"5 for the third CAPER step. First tritium tests with a technical scale PERMCAT reactor led to similar decontamination factors and clearly demonstrated that the ...
2003-09-01
Energy Technology Data Exchange (ETDEWEB)
In the development of the man-made island siting technology of nuclear power plants, assessing the stability of the seawall against large ocean waves and earthquakes is indispensable. Concerning with the seismic stability of the seawall, prediction of the deformation like sliding and settlement of the seawall during earthquake including the armour units in front of the caisson becomes important factor. For this purpose, the authors have developed the two-dimensional DEM-FEM coupled analysis method (SEAWALL-2D) to predict the deformation of the seawall covered with the armour units during earthquake. In this method, movements of the armour units are calculated in DEM analysis part and deformation of the caisson, rubble moundsand seabed and back fill are calculated in FEM analysis part taking the nonlinearity of the soil materials based on the effective stress into account. Numerical simulations of dynamic centrifuge model tests of the seawall ...
1999-02-01
Sealing of nuclear plant electrical equipment: Final report
International Nuclear Information System (INIS)
The nuclear power industry has many applications where electrical equipment is required to operate in environments which contain high relative humidity, steam and water or chemical sprays. Equipment is susceptible to these environments by moisture entering through inherent design provisions such as O-rings and through the electrical interface. The objective of this research is to review electrical interface sealing techniques and to recommend methods for providing effective electrical interface sealing. The most common methods of sealing are the use of electrical fittings containing sealants, add-on assemblies and hardware changeout. The experience gained in several years of testing electrical interface seals on such devices as limit switches, solenoid valves and transmitters is presented to provide information on seal effectiveness and preferred application. The effectiveness of various sealing methods is discussed, each of which is dependent upon the device being ...
Reduction of combustion emissions using hydrogen peroxide in a pilot scale combustion chamber
Energy Technology Data Exchange (ETDEWEB)
A hydrogen peroxide injection system was designed and installed in the stack of a 5,274 million J/hr industrial pilot plant scale combustion chamber using natural gas as fuel. The concentration of peroxide in the gas stream was precisely controlled by continuous injection using an electromagnetic dosage pump, the liquid 50% peroxide solution was finely dispersed into the gases by a water cooled custom designed delivery system with a spray nozzle at the tip. Residence times between 0.1 and 1.8 seconds and concentrations of H{sub 2}O{sub 2} between 280 ppm and 4,000 ppm were used during the test runs. CEMS for total hydrocarbons, carbon monoxide, nitrogen oxides, as well as an ultrasonic gas flow monitor were used to measure the effect of hydrogen peroxide in reducing the emissions of these pollutants. Destruction removal efficiencies between 25% and 100% were observed for hydrocarbons, and concentrations of CO, as well as NO{sub x}. were reduced ...
1997-12-31
Energy Technology Data Exchange (ETDEWEB)
Kaiser Alumina and Chemical Co. impounds red mud, the byproduct of alumina production, behind levees. Kaiser recognizes that this action cannot be maintained indefinitely. Therefore, a project is in progress to produce useful products from red mud that increase the profitability of the Gramercy facility. Before products could be developed, an obstacle had to be overcome. The annual rainfall in South Louisiana prevents evaporative drying of the mud lakes. Innovative methods were applied to dry the lake mud. Two products have been developed. A daily landfill cover and an absorbant, which are marketed under the Cajunite{trademark} banner. Both products are currently being tested by potential customers at their sites. Environmental concerns were addressed during development. Extensive TCLP results show no metal leachate problems. All pilot tests and plant trials received LADEQ approval. Products that are under development ...
1996-10-01
Radiation hardening of CMOS-based circuitry in SMART transmitters
International Nuclear Information System (INIS)
Process control transmitters that incorporate digital signal processing could be used advantageously in nuclear power plants; however, because such transmitters are too sensitive to radiation, they are not used. The Electric Power Research Institute sponsored work at Sandia National Laboratories under EPRI contract RP2614-58 to determine why SMART transmitters fail when exposed to radiation and to design and demonstrate SMART transmitter circuits that could tolerate radiation. The term ''SMART'' denotes transmitters that contain digital logic. Tests showed that transmitter failure was caused by failure of the complementary metal oxide semiconductors (CMOS)-integrated circuits which are used extensively in commercial transmitters. Radiation-hardened replacements were not available for the radiation-sensitive CMOS circuits. A conceptual design showed that a radiation-tolerant transmitter could be constructed. A prototype for an analog-to-digital ...
Pilot-scale testing of pyrolysis for the volume reduction of organic waste
Energy Technology Data Exchange (ETDEWEB)
Pilot-scale pyrolysis units have been in operation since 1980 to test the efficiency of thermal treatment of transuranic (TRU) solid waste to retrieve the TRUs and to reduce the volume of wastes such as spent solvent, spent resin, and others. These wastes are generated by reprocessing, fuel production, and utilities. NUKEM has developed a criticality-safe, ring-slab reactor to decompose solid TRU waste. The plant processes 25 kg/h with a polyvinyl chloride content up to 70%. The overall throughput (inactive) up to the spring of 1982 was 2000 kg. The decontamination factor for the reactor itself is 1000. The liquid wastes, mainly spent solvent, are cracked under nitrogen at 400 to 700/sup 0/C in a reactor that is filled by a packed bed kept in motion by a specially designed agitator. This unit was built for 15 kg/h water equivalent evaporation. Up to 1982 the unit processed 2000 kg of spent solvent (simulated) overall. The decontamination factor ...
1982-11-01
Pilot-scale testing of pyrolysis for the volume reduction of organic waste
International Nuclear Information System (INIS)
Pilot-scale pyrolysis units have been in operation since 1980 to test the efficiency of thermal treatment of transuranic (TRU) solid waste to retrieve the TRUs and to reduce the volume of wastes such as spent solvent, spent resin, and others. These wastes are generated by reprocessing, fuel production, and utilities. NUKEM has developed a criticality-safe, ring-slab reactor to decompose solid TRU waste. The plant processes 25 kg/h with a polyvinyl chloride content up to 70%. The overall throughput (inactive) up to the spring of 1982 was 2000 kg. The decontamination factor for the reactor itself is 1000. The liquid wastes, mainly spent solvent, are cracked under nitrogen at 400 to 700"0C in a reactor that is filled by a packed bed kept in motion by a specially designed agitator. This unit was built for 15 kg/h water equivalent evaporation. Up to 1982 the unit processed 2000 kg of spent solvent (simulated) overall. The decontamination factor is ...
Energy Technology Data Exchange (ETDEWEB)
With a pilot electrostatic precipitator having wider plate spacings than usual tests were performed under industrial conditions. In the two-section two-duct pilot precipitator with a precipitation area of 60 m/sup 2/ the plate spacing was increased up to 1,000 mm. As gas velocities values between 0.5 and 2.0 m/s were selected. The precipitator was tested with the flue gases of a coal-fired power station and in the room dedustion of an iron ore sintering plant. Starting with a plate spacing of 250 mm increasing the spacing results initially in a small increase of the precipitation rate. After reaching a maximum the rate decreases and finally with passing a critical spacing it goes below the initial value. Dedusting flue gases the spacing with the maximum and the critical spacing depend on the gas velocity. Cost analyses demonstrate that increasing the up to now used plate spacings may led to considerable savings. Depending ...
1983-01-01
Natural circulation cooling in US Pressurized Water Reactors
International Nuclear Information System (INIS)
This document is a synthesis of data and analysis concerning natural circulation cooling in US Pressurized Water Reactors during off-normal operation and accident transients. Its objective is the integration of important research findings concerning PWR natural circulation phenomena into a single reference document. Sources of information include the Nuclear Regulatory Commission, reactor vendors, utility sponsored research groups, utilities, national laboratories, research reports, meeting papers, archival literature, and foreign sources. Three modes of natural circulation are discussed: single-phase, two-phase, and reflux/boiling condensation. General characteristics, analytical expressions, noncondensible gas effects, secondary effects, and nonuniform flow are described with regard to each of the natural circulation modes. Plant operational data, tests in scaled experimental facilities, and analysis with thermal hydraulic system codes have ...
Licensing experiences of safety critical software systems in nuclear applications a case study
Energy Technology Data Exchange (ETDEWEB)
This paper summarizes results of reviews on the safety, critical software performed during the licensing process for the new Wolsung units. Each of these CANDU-type nuclear power plants has two micro-computerized shutdown systems. The SDS No. 1 program is graphically programmed in such a manner that its development process does not essentially differ from the design process of the conventional analog counterpart. This approach is understandable even to a reviewer in the regulatory agency without additional training in software engineering. The confidence in the reliability of this system is strengthened by the reverse verification and increased by extensive testing such as the reliability test. Concerning SDS No. 2, the development process is significantly influenced by the {open_quotes}software cost reduction project{close_quotes} of the U.S. naval research laboratory, and is, as a whole, clear and well structured except ...
1997-12-01
Licensing experiences of safety critical software systems in nuclear applications a case study
International Nuclear Information System (INIS)
This paper summarizes results of reviews on the safety, critical software performed during the licensing process for the new Wolsung units. Each of these CANDU-type nuclear power plants has two micro-computerized shutdown systems. The SDS No. 1 program is graphically programmed in such a manner that its development process does not essentially differ from the design process of the conventional analog counterpart. This approach is understandable even to a reviewer in the regulatory agency without additional training in software engineering. The confidence in the reliability of this system is strengthened by the reverse verification and increased by extensive testing such as the reliability test. Concerning SDS No. 2, the development process is significantly influenced by the software cost reduction project of the U.S. naval research laboratory, and is, as a whole, clear and well structured except for the modules related to ...
1997-06-01
Energy Technology Data Exchange (ETDEWEB)
This study is part of a greater project from IPT (Sao Paulo's Institute of Technology), which foresaw an energetic use for elephant-grass (Pennisetum purpureum). Biomass gasification is an sustainable option for energy supply, which presents low pollutants emission rate and allows - through the global cycle of growing and consumption of feedstock (vegetables), a balance between consumption and production of carbonic gas, preventing an increase of the carbonic gas levels in the atmosphere. A gasifier was built with internal diameter of 400 mm and total height of 4600 mm . The equipment was tested for gasification of elephant-grass (Pennisetum purpureum) at a 100 kg/h rate. The equipment was tested and some constructive faults were detected. In the countryside, this biomass is commonly used for cattle feeding It was evaluated an adequate diesel-electric-generator. to work at hybrid regime, using 70% biomass gas and 30% diesel. With the ...
2000-07-01
Fundamental investigation of duct/ESP phenomena
Energy Technology Data Exchange (ETDEWEB)
This report describes in detail the First Generation Duct Injection Model developed for the analysis of the fundamental processes of flue gas desulfurization by sorbent injection. The model is a two- and three-dimensional, multiphase reacting flow analyzer using computational fluid dynamics methods. The gaseous phase is solved in an Eulerian frame while the droplets or particles are tracked in a Lagrangian frame. The model has an associated preprocessor which allow easy problem set up by the use without in-depth knowledge of computational fluid dynamics. The aerodynamics of the First Generation Duct Injection Model have been successfully validated with a number of test cases for which experimental data are available. Data from the Meredosia pilot plant humidification tests have been used to validate the gas and droplet dynamics of the model with good agreement. Comparison of SO{sub 2} removal results using the present model ...
1990-12-01
Externally fired combined cycle demonstration
Energy Technology Data Exchange (ETDEWEB)
Externally Fired Combined Cycles (EFCCs) can increase the amount of electricity produced from ash bearing fuels up to 40%, with overall powerplant efficiencies in excess of 45%. Achieving such high efficiencies requires high temperature-high pressure air heaters capable of driving modern gas turbines from gas streams containing the products of coal combustion. A pilot plant has been constructed in Kennebunk, Maine to provide proof of concept and evaluation of system components. Tests using pulverized Western Pennsylvania bituminous coal have been carried out since April, 1995. The ceramic air heater extracts energy from the products of coal combustion to power a gas turbine. This air heater has operated at gas inlet temperatures over 1,095 C and pressures over 7.0 atm without damage to the ceramic tube string components. Stable gas turbine operation has been achieved with energy input from the air heater and a supplementary gas fired combustor. ...
1995-11-01
Ensuring the 50 year life of a fissile material container
Energy Technology Data Exchange (ETDEWEB)
Sandia was presented with an opportunity in 1993 to design containers for the long term storage and transport of fissile material. This program was undertaken at the direction of the US Department of Energy and in cooperation with Lawrence Livermore National Laboratory and Los Alamos National Laboratory which were tasked with developing the internal fixturing for the contents. The hardware is being supplied by Allied Signal Federal Manufacturing and Technologies, and the packaging will occur at Mason and Hangar Corporation`s Pantex Plant. The unique challenge was to design a container that could be sealed with the fissile material contents; and, anytime during the next 50 years, the container could be transported with only the need for the pre-shipment leak test. This required not only a rigorous design capable of meeting the long term storage and transportation requirements, but also resulted in development of a surveillance program to ensure ...
1997-12-01
Effect of grain size on engineering properties of coal ash
Energy Technology Data Exchange (ETDEWEB)
The main object of the present study was to obtain the relationship of primary, secondary and index properties; compressibility; and angle of repose of coal ash. Representative samples of coal ash from different storage locations of Ropar thermal power plant, Punjab, were analysed. Based on test results of various primary characteristics of ash, the following observations have been made. (1) Ashes sampled for the study have a common mineralogical origin. The uniformity coefficient increases for ash collected near location of discharge compared to ash collected far from the location. (2) The void ratio extent, that is, a different of emax. or a ratio of emax. and emin. decreases with an increase of mean size. The maximum dry density obtained in dry vibration and proctor test differs for fine ash. Maximum dry density decreases and optimum moisture content increases with increase in mean size. Permeability of ash at proctor ...
2003-07-01
Disposal of spent fuel from German nuclear power plants - paper work or technology?
International Nuclear Information System (INIS)
The reference concept 'direct disposal of spent fuel' was developed as an alternative to spent fuel reprocessing and vitrified HLW disposal. The technical facilities necessary for the implementation of this reference concept - the so called POLLUX-concept, e.g. interim storages for casks containing spent fuel, a pilot conditioning facility, and a special cask 'POLLUX' for final disposal have been built. With view to a geological salt formation all handling procedures for the repository were tested aboveground in a test facility at a 1:1 scale. To optimise the concept all operational steps are reviewed for possible improvement. Most promising are a concept using canisters (BSK 3) instead of POLLUX casks, and the direct disposal of transport and storage casks (DIREGT-concept) which is the most recent one and has been designed for the direct disposal of large transport and storage casks. The final exploration of the pre-selected repository site is ...
2006-09-17
Development of radioisotope tracer technology
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to develop the radioisotope tracer technology, which can be used in solving industrial and environmental problems and to build a strong tracer group to support the local industries. In relation to the tracer technology in 1999, experiments to estimate the efficiencies of a sludge digester of a waste water treatment plant and a submerged biological reactor of a dye industry were conducted. As a result, the tracer technology for optimization of facilities related to wastewater treatment has been developed and is believed to contribute to improve their operation efficiency. The quantification of the experimental result was attempted to improve the confidence of tracer technology by ECRIN program which basically uses the MCNP simulation principle. Using thin layer activation technique, wear of tappet shim was estimated. Thin layer surface of a tappet shim was irradiated by proton beam and the correlation between the measured activity loss ...
2000-04-01
Development of BWR core flow measurement technology using in-core neutron fluctuating signals
Energy Technology Data Exchange (ETDEWEB)
The extensive work on the measurement technology of total and local flow rates in BWR core has been performed using in-core neutron fluctuating signals. Based on a large amount of actual data acquired from commercial BWR plants in operation, physical interpretation was discussed on the transit time of the neutron fluctuating signals. The new findings against the logical inconsistency of the transit time between the different LPRM detector positions lead to a promised core flow measurement algorithm using in-core neutron fluctuating signals. The advanced on-line core flow measurement system was developed and tested during the startup phase of the first ABWR. The measurement test results demonstrate the present core flow measurement system within the errors of 5 through 10% over the wide operating area besides the capability for the local void fraction and two-phase flow regime monitoring. (author)
1997-09-01
Crud removal performance with ion exchange resins in BWR plants
Energy Technology Data Exchange (ETDEWEB)
It is needless to say that one of the most important roles of the condensate demineralizer in Japanese boiling water reactors (BWR) is to eliminate such impurities during accidental occurrence of sea water leakage from condensate cooling system. Ion exchange resins packed in condensate demineralizer have also been expected to decrease crud, or corrosion products (CP) in condensate water in order to finally reduce activated corrosion products (ACP) in the reactor coolant loop. It is perceived that crud removal ability of a condensate demineralizer has been improved year by year. And we call this phenomenon as `Aging Effect`. Typical property changes of aged cation exchange resin consisted of an increase of water retention capacity and a change of surface texture. Based on these findings, we formulated a new concept and developed new gel type ion exchange resins for the better crud removal. The results from column tests using actual condensate water for approximately ...
1996-01-01
Condensation driven water hammer studies for feed water distribution pipe
International Nuclear Information System (INIS)
Special T-shaped feedwater distribution pipes were installed in steam generators at the Loviisa (Finland) and Rovno (Russia) nuclear power plants. The new shape was tested in an extensive testing programme. Since the tubes frequently suffer from corrosion damage, large-scale water hammer experiments were performed on a model facility in 1996. The main objectives of the water hammer experiments were to find out the prevailing parameters leading to water hammers, as well as the sensitivity of hammering to boundary conditions. A water hammer may occur when the mass flow rate into the steam generator exceeds 6 kg/s and the temperature difference between steam generator and feedwater exceeds 100 degC. Visual experiments and stress analyses of the pipe were also carried out. The weakest part, the T-joint, may hold against such water hammers only for a limited time of the order of few minutes. (M.D.).
1997-05-26
Break Nodalization Influence to IAEA-SPE-4 Test Simulation
International Nuclear Information System (INIS)
A small break LOCA event simulation with no high pressure injection system available, known as International Atomic Energy Agency Standard Problem Exercise no. 4 (IAEA-SPE-4), was performed on the PMK-2 integral test facility in Budapest in 1993. This paper analyses the response of the PMK-2 facility, a model of VVER-440 nuclear power plant, using the latest released version MOD3.2.1.2 of the RELAP5 thermal-hydraulic code. After several years of the SPE-4 experiment analyses, many problems have emerged and been studied. Main goal of the present analyses was to study the main influencing parameters for adequate modelling of the hexagonal core channel with 19-rod bundle and phenomena during the core uncovery. Some influencing parameters have been identified, mostly on the primary side, but some also on the secondary side. This is exact simulation of main coolant pump coast down, hydro-accumulators water temperature and connections to the primary ...
1998-06-15
Migration of strontium in the food chain of plants, animals and man - problems and risks
International Nuclear Information System (INIS)
The aims of investigation were to follow the Sr transport in the food chain from the flora to the fauna and humans, and its dependence on the geological origin og the plant site, industrial emissions, the age and site of plants, the part of plant used for nutrition and the strontium content in the drinking water, to determine the Sr intake of humans with the help of the duplicate method, and to estimate the apparent absorption rate and balance of strontium depending on of the form of diet (mixed or ovolactovegetarian), sex, season, age, region (geological origin of the living space) and method of intake measurement (duplicate or basket method). Strontium, an ultra trace element widespread in the earth's crust, is not essential and only mildly toxic for plants, animals and man according to current knowledge. The biological essentiality of Sr has not been investigated yet. Amoeba species living in sea ...
2008-10-15
Energy Technology Data Exchange (ETDEWEB)
The development and improvement of materials plays a key role in energy technology, particularly in power plant technology, because materials are crucial to plant performance and power availability. This becomes particularly clear when one considers that modern power plants generate temperatures of up to 600 C and pressures of up to 230 bar in order to increase process efficiency, conserve resources and reduce CO{sub 2} emissions. Modern heat-resistant materials for power plant technology are customised materials which have been developed to meet the specific requirements of special applications. After the requirement profile has been determined the material is developed or optimised on the basis of previous experiences gained with materials in power plant technology. Basic heat-resistant materials are ferritic materials containing 9 to 12% Cr as well as additions of Mo, V, Nb and ...
2000-07-01
DWPF Recycle Evaporator Shielded Cells Testing
Testing was performed to determine the feasibility and processing characteristics of evaporation of actual Defense Waste Processing Facility (DWPF) recycle material. Samples of the Off Gas Condensate Tank (OGCT) and Slurry Mix Evaporator Condensate Tank (SMECT) were transferred from DWPF to the Savannah River National Lab (SRNL) Shielded Cells and blended with De-Ionized (DI) water and a small amount of Slurry Mix Evaporator (SME) product. A total of 3000 mL of this feed was concentrated to approximately 90 mL during a semi-batch evaporation test of approximately 17 hours. One interruption occurred during the run when the feed tube developed a split and was replaced. Samples of the resulting condensate and concentrate were collected and analyzed. The resulting analysis of the condensate was compared to the Waste Acceptance Criteria (WAC) limits for the F/H Effluent Treatment Plant (ETP). Results from the ...
2005-07-01
Regulatory experience on safety system instrument uncertainty of Wolsong units
International Nuclear Information System (INIS)
This paper presents the regulatory experience gained from Wolsong Units 2,3 and 4 - Special Safety System Instrumentation Uncertainty for Trip Setpoint and Allowable Values. The equipment diversity method for the defense against common mode failure was applied to the transmitters of shutdown system number 2. However the Units experienced an unexpected drift problem with which the performance did not meet the Technical Specification (Tech Spec) Surveillance Requirements (SR). Discussed are the background, status and corrective actions, regulatory positions and issues to be solved for the drift problem. It was an instrument uncertainty methodology that the designer of safety system should have shown when the drift problem occurred. For deeper understanding of the problem, we present the background of Tech Spec SR for setpoints in Korean PWR and in CANDU reactors. The Setpoint Verification Test(SVT) and Calibration Test(CT) shall be achieved by ...
2001-05-01
Natural resource injury assessment of a crude oil spill
International Nuclear Information System (INIS)
In January 1994, a 6.7 magnitude earthquake in southern California ruptured a pipeline releasing approximately 4,200 barrels of blended San Joaquin Valley crude oil. A smaller volume entered the Santa Clara River and flowed 25 km downstream to an emergency containment dam. Ruptured water mains and chlorinated discharges from a damaged sewage treatment plant also affected water quality in the river. Quantitative injury assessment studies were initiated within days of the spill and included water/sediment chemistry, benthic macroinvertebrate community analyses and aquatic toxicity tests. Water quality values for TPH, BTEX, and chlorine ranged from nondetectable to 78 mg/l (TPH), nondetectable to 5.4 microg/l (total BTEX constituents) and nondetectable to 600 microg/l (residual chlorine) within 72 hours of the spill. Ammonia concentrations ranged from nondetectable to 12.1 mg/l within 10 days of the spill. Hydrocarbon concentrations in sediments ...
1996-11-17
Deliberate ignition of hydrogen-air-steam mixtures in condensing steam environments
Energy Technology Data Exchange (ETDEWEB)
Large scale experiments were performed to determine the effectiveness of thermal glow plug igniters to burn hydrogen in a condensing steam environment due to the presence of water sprays. The experiments were designed to determine if a detonation or accelerated flame could occur in a hydrogen-air-steam mixture which was initially nonflammable due to steam dilution but was rendered flammable by rapid steam condensation due to water sprays. Eleven Hydrogen Igniter Tests were conducted in the test vessel. The vessel was instrumented with pressure transducers, thermocouple rakes, gas grab sample bottles, hydrogen microsensors, and cameras. The vessel contained two prototypic engineered systems: (1) a deliberate hydrogen ignition system and (2) a water spray system. Experiments were conducted under conditions scaled to be nearly prototypic of those expected in Advanced Light Water Reactors (such as the Combustion Engineering (CE) System 80+), with ...
1997-05-01
Energy Technology Data Exchange (ETDEWEB)
For evaporation crystallization of extremely corrosive FGD scrubber solutions which - depending on the process - can lead all the way to a product suitable for depositing, an economic equipment concept based on metallic construction materials was to be investigated. In a parameter study, electrochemical test methods were used to determine the influence of the pH value, the Fe{sup 3+}, F and So{sub 2} contents in a solution containing 200 g/l CaCl{sub 2}+30 g/l NaCl at 80deg C on the resistance to pitting corrosion of stainless steels and NiCrMo alloys. In addition, electrochemical and wet corrosion tests (e.g. crevice corrosion) were conducted using original FGD scrubber solutions with 43-50% dry substance from the power plants Reuter-West, Oberhavel and Rudow of the BEWAG, Berlin. The results were compared to those of standardized and non-standardized short-term tests for determining the critical ...
1991-08-05
Energy Technology Data Exchange (ETDEWEB)
This Waste Management Plant (WMP) for the Bear Creek Valley Treatability Study addresses waste management requirements for the Oak Ridge Y-12 Plant. The study is intended to produce treatment performance data required to design a treatment system for contaminated groundwater. The treatability study will consist of an evaluation of various treatment media including: continuous column tests, with up to six columns being employed to evaluate the performance of different media in the treatment of groundwater; an evaluation of the denitrifying capacity and metal uptake capacity of a wetland system; and the long-term denitrifying capacity and metal uptake capacity of algal mats. The Sampling and Analysis Plan (SAP) covers the project description, technical objectives, procedures, and planned work activities in greater detail. The Health and Safety Plan (HASP) addresses the health and safety concerns and requirements for the ...
1997-05-01
Energy Technology Data Exchange (ETDEWEB)
The AVR experimental nuclear reactor was Professor Dr. Rudolf Schulten's brainchild. Visionary ideas led to the success of this technology: - Helium coolant because of the particularly high heat transfer coefficients; - an integrated primary system reactor concept as the basis of all safety considerations in the interest of maximum safety; - uranium-235 and thorium-232 fuel allowing new fuel to be bred; - high temperatures for electricity generation at maximum thermodynamic efficiencies, i.e. optimum fuel utilization; - the possibility to run chemical processes economically at high temperatures by means of nuclear fuels; - the inherent safety of the reactor, for a major accident accompanied by a complete loss of cooling cannot occur for nuclear physics reasons, as was tested twice in the AVR. The AVR attained its first criticality on August 28, 1968. It was operated for more than 20 years, until December 31, 1988, at approximately 67% time utilization, ...
2009-12-15
International Nuclear Information System (INIS)
The AVR experimental nuclear reactor was Professor Dr. Rudolf Schulten's brainchild. Visionary ideas led to the success of this technology: - Helium coolant because of the particularly high heat transfer coefficients; - an integrated primary system reactor concept as the basis of all safety considerations in the interest of maximum safety; - uranium-235 and thorium-232 fuel allowing new fuel to be bred; - high temperatures for electricity generation at maximum thermodynamic efficiencies, i.e. optimum fuel utilization; - the possibility to run chemical processes economically at high temperatures by means of nuclear fuels; - the inherent safety of the reactor, for a major accident accompanied by a complete loss of cooling cannot occur for nuclear physics reasons, as was tested twice in the AVR. The AVR attained its first criticality on August 28, 1968. It was operated for more than 20 years, until December 31, 1988, at approximately 67% time utilization, which is an ...
2009-12-01
International Nuclear Information System (INIS)
An eddy current inspection has been applied for a pre-service and in-service examination of a steam generator in nuclear power plants. The experience from the inspection of steam generators showed that many plants had an excessive number of tubes with eddy current noise signals over several hundreds, which originated from manufacturing anomalies. The plants in U.S suffered significant downstream inspection costs, history reviews, and diagnostic testing because some signals resembled flaws and others masked a flaw. These lessens learned resulted in issuing the guidelines for steam generator tubing specifications and repair, in order to reduce the number of anomalous signals in the tubes and also to provide the requirement of a signal to noise ratio by applying a field type examination with bobbin coil eddy current probes at a manufacturing process. Besides the noise signals of a bobbin coil eddy current ...
2008-05-01
Energy Technology Data Exchange (ETDEWEB)
The Rocky Flats Plant, located approximately 26 km northwest of downtown Denver, Colorado, has developed an emergency response atmospheric dispersion model for complex terrain applications. Plant personnel would use the model, known as the Terrain-Responsive Atmospheric Code (TRAC) (Hodgin 1985) to project plume impacts and provide off-site protective action recommendations to the State of Colorado should a hazardous material release occur from the facility. The Colorado Department of Health (CDH) entered into an interagency agreement with the Rocky Flats Plant prime contractor, EG&G Rocky Flats, and the US Department of Energy to evaluate TRAC as an acceptable emergency response tool. After exhaustive research of similar evaluation processes from other emergency response and regulatory organizations, the interagency committee devised a formal acceptance process. The process contains an evaluation protocol (Hodgin and ...
1993-10-01
Energy Technology Data Exchange (ETDEWEB)
Chapter 2 describes the worldwide increase of primary energy consumption, which is expected in coming decades and results in possible solutions of a decentralised energy supply that is mainly based upon renewable energy carriers and the use of cogeneration systems. Chapter 3 shows the characteristics of decentralised system components that have been investigated in the frame of this research work as well as the resulting model library to depict the operational performance of the individual components and their mutual influence. A detailed dynamic simulation of a complete fuel cell system based on a steam reformer including the concept of local and superordinate control circuits is presented in chapter 4. Chapter 5 includes the integrated concepts for the intelligent and adaptable management of complex decentralised energy systems as well as a description of their implementation. Apart from the applied metaheuristic optimization methods the adaptable fuzzy-system, used in this case, is ...
2007-06-28
On-line tuning of a fuzzy-logic power system stabilizer
International Nuclear Information System (INIS)
A scheme for on-line tuning of a fuzzy-logic power system stabilizer is presented. firstly, a fuzzy-logic power system stabilizer is developed using speed deviation and accelerating power as the controller input variables. The inference mechanism of fuzzy-logic controller is represented by a decision table, constructed of linguistic IF-THEN rules. The Linguistic rules are available from experts and the design procedure is based on these rules. It assumed that an exact model of the plant is not available and it is difficult to extract the exact parameters of the power plant. Thus, the design procedure can not be based on an exact model. This is an advantage of fuzzy logic that makes the design of a controller possible without knowing the exact model of the plant. Secondly, two scaling parameters are introduced to tune the fuzzy-logic power system stabilizer. These scaling parameters are the outputs of another fuzzy-logic ...
2002-01-01
Energy Technology Data Exchange (ETDEWEB)
About ten years ago microbiologically influenced corrosion manifested on stainless steel pipes used with river water for cooling a chemical plant. The pipe material was similar to Type 316 L. After only six weeks of operation pinhole leaks occurred nearly simultaneously at several welded joints of the pipe. The material degradation was simulated in laboratory and field corrosion tests. Microbiologically influenced corrosion failures also appeared on the pipes of a tubular heat exchanger of duplex steel Type 31803 and on carbon and stainless steel pipes in industrial waste water purification plants after these plants had been modernized with a biological purification unit. The basics of microbiologically influenced corrosion phenomena and typical corrosion failures of pipes will be described. (orig.) [German] Vor etwa zehn Jahren sind in einer neu errichteten chemischen Produktionsanlage an einer mit ...
1999-09-01
Full-scale soil washing/TERRAMET{reg_sign} soil leaching
Energy Technology Data Exchange (ETDEWEB)
COGNIS TERRAMET{reg_sign} soil leaching and Bescorp soil washing systems have been successfully combined to remediate an ammunition test burn area at the Twin Cities Army Ammunition Plant (TCAAP), New Brighton, MN. This cleanup is the first in the country to combine these two technologies, and this approach offers a permanent remedial solution. In Fall 1993, 1,600 tons of soil were remediated with an additional 10,000+ tons treated in 1994. The cleaned soil remained on-site, and the heavy metal contaminants were removed, recovered, and recycled. Eight heavy metals were removed from the contaminated soil achieving the very stringent cleanup criteria of <175 ppm for residual lead and achieving background concentrations for seven other heavy metals (antimony, cadmium, chromium, copper, mercury, nickel, and silver). In addition, both live and spent ordnance had to be removed in the soil treatment plant to meet the cleanup ...
1995-09-01
International Nuclear Information System (INIS)
Chinese brake fern (Pteris vittata L.), an arsenic (As) hyperaccumulator, has shown the potential to remediate As-contaminated soils. This study investigated the effects of soil amendments on the leachability of As from soils and As uptake by Chinese brake fern. The ferns were grown for 12 weeks in a chromated-copper-arsenate (CCA) contaminated soil or in As spiked contaminated (ASC) soil. Soils were treated with phosphate rock, municipal solid waste, or biosolid compost. Phosphate amendments significantly enhanced plant As uptake from the two tested soils with frond As concentrations increasing up to 265% relative to the control. After 12 weeks, plants grown in phosphate-amended soil removed >8% of soil As. Replacement of As by P from the soil binding sites was responsible for the enhanced mobility of As and subsequent increased plant uptake. Compost additions facilitated As uptake from the CCA ...
2003-11-01
A Virtual Engineering Framework for Simulating Advanced Power System
Energy Technology Data Exchange (ETDEWEB)
In this report is described the work effort performed to provide NETL with VE-Suite based Virtual Engineering software and enhanced equipment models to support NETL's Advanced Process Engineering Co-simulation (APECS) framework for advanced power generation systems. Enhancements to the software framework facilitated an important link between APECS and the virtual engineering capabilities provided by VE-Suite (e.g., equipment and process visualization, information assimilation). Model enhancements focused on improving predictions for the performance of entrained flow coal gasifiers and important auxiliary equipment (e.g., Air Separation Units) used in coal gasification systems. In addition, a Reduced Order Model generation tool and software to provide a coupling between APECS/AspenPlus and the GE GateCycle simulation system were developed. CAPE-Open model interfaces were employed where needed. The improved simulation capability is demonstrated on selected ...
2008-06-18
International Nuclear Information System (INIS)
A multielement apparatus for the removal of aerosols formed in the vitrification of simulated high-activity accident wastes from the decommissioned nuclear power plant A-1 has been designed, manufactured and tested. The apparatus consists of two cooling and condensing steps connected in series, and of five filtration steps also connected in series. The five filtration steps allowed to achieve a decontamination factor of 1x10"5 in the case of removal of a NaCl("2"4Na) testing model aerosol. The decontamination factor for removal of the cesium aerosol by the whole apparatus was 3.3x10"6. In the first filtration step the aerosols are removed by the cartridge with a filtration fabric made of polyethylene fibers, in the second step by the cartridge with a granulated natural material, in the third step by the cartridge with glass-fiber filtration paper, in the fourth and fifth steps by the cartridge with high-efficiency ...
Energy Technology Data Exchange (ETDEWEB)
The Department of Toxic Substance Control (DTSC) requested that Lawrence Livermore National Laboratory (LLNL) evaluate the treatment process currently employed at the Department's Stringfellow Superfund Site Pretreatment Plant (PTP) site to determine if wastes originating from the site were properly managed with regards to their radioactivity. In order to evaluate the current management strategy, LLNL suggested that DTSC characterize the effluents from the waste treatment system for radionuclide content. A sampling plan was developed; samples were collected and analyzed for radioactive constituents. Following is brief summary of those results and what implications for waste characterization may be made. (1) The sampling and analysis provides strong evidence that the radionuclides present are Naturally Occurring Radioactive Material (NORM). (2) The greatest source of radioactivity in the samples was naturally occurring uranium. The sample results indicate ...
2005-09-16
International Nuclear Information System (INIS)
The Department of Toxic Substance Control (DTSC) requested that Lawrence Livermore National Laboratory (LLNL) evaluate the treatment process currently employed at the Department's Stringfellow Superfund Site Pretreatment Plant (PTP) site to determine if wastes originating from the site were properly managed with regards to their radioactivity. In order to evaluate the current management strategy, LLNL suggested that DTSC characterize the effluents from the waste treatment system for radionuclide content. A sampling plan was developed; samples were collected and analyzed for radioactive constituents. Following is brief summary of those results and what implications for waste characterization may be made. (1) The sampling and analysis provides strong evidence that the radionuclides present are Naturally Occurring Radioactive Material (NORM). (2) The greatest source of radioactivity in the samples was naturally occurring uranium. The sample results indicate that the ...
Fire preventive materials for nuclear power plants
International Nuclear Information System (INIS)
With the fire accident in Browns Ferry nuclear power plant as a turning point, the regulation against fire has been strengthened more strictly as seen in the regulatory guide of the United States Nuclear Regulatory Commission. Fire of cables is caused by either the ignition of a cable itself or spread of fire to cables. The aspect of fire is divided into the local ignition and combution and the fire extension and prepagation because of the line-shaped configuration of cables. This report describes the prevention of the spread of fire. As the materials for the prevention of fire spread, fire spread-preventing paint ''Dannekka'', sealant ''Danseal P and L'', and fire prevention tape ''FD tape'' are reported, and the testing method and the results are described in detail. ''Dannekka'' is classified into the solvent dispersion type and the water dispersion type. It may be coated with brush or by spraying. Seal material is required not only to be ...
Energy Technology Data Exchange (ETDEWEB)
Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams. An initial dye-tracer study was conducted during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. A second dye-tracer was conducted during the wet weather season. The actual test commenced during the first week of February 1992 with a 4-week baseline monitoring period to determine the inherent variability of the emission ...
1992-11-01
Nuclear power plants connected with pumped storage plants by the inland lakes
International Nuclear Information System (INIS)
Finnish (May 1971). Finland Kilpelaeinen, JE Imatran Voima Osakeyhtio,
1971-01-01
Hydroelectric Power Plants Electrical Design
... Treatment of electrical systems for pumped storage plants is not covered in the manual, although much of the information is applicable to pumped ...
1994-06-30
Development of Guide System for a Reactor Head Maintenance Robot
Energy Technology Data Exchange (ETDEWEB)
The Control Rod Drive(CRD) nozzles for PWR nuclear power plants(NPP) house the control rod drives. The number of nozzle penetrations range from the mid-30's to over 100 in each reactor head. The integrity of CRD nozzles is very important, because the primary pressure boundary is established with the J-groove weld joining the nozzle to the head clad surface. The Alloy 600 PWSC CRD nozzle leaks discovered in the fall of 2000 and spring of 2001 in several US plants. Therefore the NRC has recommended a more proactive effort by US utilities to inspect similarly susceptible nozzles in all US plants. The primary safety concern is circumferential cracks that can permit the nozzles to separate from the head at high velocity and produce a large-break leak in the reactor vessel. A secondary concern is head leakage from any through-wall cracks in the nozzle or J-groove weld area. Numerous inspection and repair tools have been ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
Instrumental neutron activation analysis (INAA) followed by gamma-ray spectrometry was used to determine the concentrations of As, Ca, Co, Cr, Cu, Eu, Fe, K, La, Mg, Mn, Mo, Na, Pr, Sb, Se, Th, U, V and Z, in 82 leaf samples belonging to two cultivars of pigeonpea (Cajanus cajan (L.) Millsp). Pigeonpea, an easy cultivation legume species, probably originated from Africa and adapted to brazilian conditions, is a very promising and unconventional source of food, mainly to the grain production intended for human feeding, and that even can be used in flour products. It is an excellent proteic supplement for ruminants, due to its large potential of forage production and its high nutritive value, or in addition it can be used in the recuperation of exhausting soils either by means of its utilization as green manure or by taking free Nitrogen from the atmosphere to produce nitrates which can be utilized by the plants. However, in spite of the several possibilities and ...
2001-07-01
Development of Guidelines for PSA-based Event Analysis (PSAEA) in an International Project
International Nuclear Information System (INIS)
A probabilistic precursor study provides a complement to the 'root cause' analysis approach by focusing on how an event might have developed adversely, and implies the mapping of an operational event on a probabilistic risk model of the plant in order to obtain a quantitative assessment of the safety significance of the event. In order to benefit from state-of-the-art PSA features but also to assure repeatability of the analysis, a comprehensive set of PSAEA guidelines was developed. This PSAEA procedure was established in 1996-1998 by Enconet Consulting in the framework of an international project on behalf of - and involving - the nuclear regulatory bodies from 6 countries: AECB (Canada), AVN (Belgium), CSN (Spain), HSK (Switzerland), NII (United Kingdom) and SKI (Sweden). The PSAEA procedure defines preliminary requirements for the PSA model and code, and identifies input requirements such as information on plant status, event sequence ...
2003-03-20
Energy Technology Data Exchange (ETDEWEB)
Initially, the decision of the operator in Dortmund-Derne to select the impact-type separator concept is explained. None of the tenderers for this 52 t/h boiler could supply references for this fluidized bed steam generator concept with staged combustion in a high-expansion fluidized bed. Under the circumstances, the simple configuration of the Steinmueller fluidized bed steam generator, its compact construction, the reduced amount of refractory and the operational behaviour of the boiler resulting therefrom were decisive in the operator`s decision to select this concept. The development schedule shows the individual stages from cold and hot trials in various test rigs and pilot plants to the final design. So far, this fluidized bed steam generator concept has been realized in the plants Derne (52 t/h), commissioned in November 1989, and Brilon (100 t/h), commissioned in November 1990. The discussion on the essential design ...
1992-12-31
EARLY ENTRANCE COPRODUCTION PLANT
The overall objective of this project is the three phase development of an Early Entrance Coproduction Plant (EECP) which uses petroleum coke to produce at least one product from at least two of the following three categories: (1) electric power (or heat), (2) fuels, and (3) chemicals using ChevronTexaco's proprietary gasification technology. The objective of Phase I is to determine the feasibility and define the concept for the EECP located at a specific site; develop a Research, Development, and Testing (RD&T) Plan to mitigate technical risks and barriers; and prepare a Preliminary Project Financing Plan. The objective of Phase II is to implement the work as outlined in the Phase I RD&T Plan to enhance the development and commercial acceptance of coproduction technology. The objective of Phase III is to develop an engineering design package and a financing and testing plan for an EECP located at a ...
2004-01-12
International Nuclear Information System (INIS)
Full text: Dissolution test (DT) is one of the important specifications of PFBR MOX fuel. It is a macro homogeneity test used to ascertain that the dissolution of spent fuel will be easier during reprocessing. The DT specification limit for PFBR MOX fuel is ? 1.0 wt.% residue of the whole pellet when it is dissolved in HNO3 under reflux conditions. For this test, sintered MOX pellet is dissolved in reflux condition in 60 ml of 12M HNO3 for 10 hours. This test is carried out for each batch and during complete MOX campaign a lot of MOX waste in liquid form is being generated. This liquid waste is in clean form and U and Pu is required to be recovered from the clean waste. Different methods like direct denitration, precipitation and solvent extraction are available but either the product is not of good quality for pelletization or secondary liquid wastes are generated. Microwave denitration is a faster and ...
2010-11-24
Kokanee Stocking and Monitoring, Flathead Lake, 1993-1994 Annual Report.
Energy Technology Data Exchange (ETDEWEB)
One mitigation goal of the Hungry Horse Dam fisheries mitigation program, funded by the Bonneville Power Administration, is to replace lost production of 100,000 adult kokanee in Flathead Lake. The mitigation program calls for a five-year test to determine if kokanee can be reestablished in Flathead Lake. The test consists. of annual stocking of one million hatchery-raised yearling kokanee. There are three benchmarks for judging the success of the kokanee reintroduction effort: (1) Post-stocking survival of 30 percent of planted kokanee one year after stocking; (2) Yearling to adult survival of 10 percent (100,000 adult salmon); (3) Annual kokanee harvest of 50,000 or more fish per year by 1998, with an average length of 11 inches or longer for harvested fish, and fishing pressure of 100,000 angler hours or more. Kokanee were the primary sport fish species in the Flathead Lake fishery in the early 1900s, and up until the ...
1995-07-01
Hydroelectric and pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is the first accessible text/reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storge plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
1989-01-01
Hydroelectric and pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is a reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storage plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
1988-01-01
Conception and design of steam power plants
International Nuclear Information System (INIS)
The manual presents the fundamentals of thermodynamics and fluid mechanics, the main components of steam power plants, and the power generation process. The following concepts and subjects are discussed at length: steam generator; steam turbines; turbogenerators; condensers; cooling technology; water/steam cycle and water treatment; design data of fossil-fuelled power plants; design and optimisation of nuclear power plant thermodynamics; pipelines and fittings; control systems in steam power plants; connection to the electricity grid and self-supply of thermal power plants; power plant transformer concepts and definitions. (HAG).
Consumable and Combustible Cartridge Cases.
The procedure describes the procedures to be used in evaluating consumable and combustible cartridge cases. Included are ballistic tests, environmental tests, adverse condition tests, fungus resistance tests, drop tests and safety tests. (Author)
1966-01-01
White Rose development plan amendment production volume increase
Energy Technology Data Exchange (ETDEWEB)
In January 2001, Husky Oil Operations Limited (Husky), in joint-venture with Petro-Canada, submitted a Benefits Plan for the White Rose Development to the Canada- Newfoundland and Labrador Offshore Petroleum Board (C-NLOPB). This revised document provided the case for requesting an increase in the facility maximum daily production rate and the average annual production rate for the White Rose field from 100,000 barrels per day (bpd) as stated in the approved White Rose Development Plan to 140,000 bpd. In order to determine the potential for increasing oil production through the Floating Production, Storage and Offloading (FPSO) vessel, two things were considered, namely the proper reservoir management of the White Rose field to ensure optimum resource recovery, and the capacity of the FPSO topsides processing system and supporting utilities to accommodate increased production. This document presented a detailed review of all the implications of increased production on the South White ...
2006-09-15
Thermal hydraulic test for core cooling system using steam generators
Energy Technology Data Exchange (ETDEWEB)
As a candidate of the new concept safety system for the next generation PWR in Japan, the hybrid safety systems, which are combination of the active and the passive safety systems, and passive core cooling system by natural circulation in the reactor coolant loop with horizontal-type steam generators during Loss of Coolant Accidents (LOCAs) are investigated. The passive safety systems are advanced accumulators (ACC), primary-side and secondary-side automatic-depressurization systems (ADS, SADS), and a gravity-driven safety injection system (GDI). The horizontal steam generator design avoids a siphon break caused from the accumulation of non-condensable gases in the tubes by using a vent line in the channel head of the steam generators. This study investigates the passive core cooling characteristics of horizontal-type steam generators under LOCAs. The integrated thermal-hydraulic test has been performed at the Simulation Loop for the Innovative Mitsubishi ...
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
The subcriticality of two interacting solution tanks was determined using /sup 252/Cf-source-driven neutron noise analysis methods. These experiments were the first test of this method for an interacting system with materials (in this case, uranyl nitrate) typical of nuclear materials in processing plants. The experiments were performed to test the conclusions from previous interaction experiments with uranium metal discs for a fissile system with moderation, and to provide data to test theoretical models for coupled systems. The uranium metal experiments showed that the subcritical neutron multiplication factor, k/sub eff/, could be determined using point kinetics without any correction for spatial effects from measurements with the source and detectors located adjacent to the same cylinder, whereas for source-detector configurations with either the source and/or detectors adjacent to different ...
1986-01-01
Effect of neutron irradiation on DHC velocity at CANDU Zr-2.5Nb pressure tube
Energy Technology Data Exchange (ETDEWEB)
The objective of this study is to evaluate the lifetime of Zr-2.5Nb pressure tube at Wolsung Unit-1. The testing materials (Effective full power year: 9.3 year, Accumulated nuetron fluence: 7.66{approx}8.91 x 1025 n/m{sup 2}) were sampled from M-11 tube at various position(inlet, middle and outlet). The cutting was carried out at hot cell to fabricate CT(Compact tension) specimen with 48 ppm hydrogen content. In the result of DHC test, irradiation-damaged specimen showed 4{approx}6 times faster DHC velocity(5.298E-0.8{approx}7.039E-8 m/s: 182 .deg. C) than non-irradiated specimen. These DHCV results also show slight faster than one of specimen from Pickering plant (average DHCV: 4.5E-8 m/s: 182 .Deg C). This faster DHCV can be explained with the fact that Wolsung Unit-1 have been operated in a severe conditions(higher cooling water temperature, high power and efficiency) than Pickering one. The striation spacing which was ...
2003-10-01
Effect of neutron irradiation on DHC velocity at CANDU Zr-2.5Nb pressure tube
International Nuclear Information System (INIS)
The objective of this study is to evaluate the lifetime of Zr-2.5Nb pressure tube at Wolsung Unit-1. The testing materials (Effective full power year: 9.3 year, Accumulated nuetron fluence: 7.66#approx#8.91 x 1025 n/m"2) were sampled from M-11 tube at various position(inlet, middle and outlet). The cutting was carried out at hot cell to fabricate CT(Compact tension) specimen with 48 ppm hydrogen content. In the result of DHC test, irradiation-damaged specimen showed 4#approx#6 times faster DHC velocity(5.298E-0.8#approx#7.039E-8 m/s: 182 .deg. C) than non-irradiated specimen. These DHCV results also show slight faster than one of specimen from Pickering plant (average DHCV: 4.5E-8 m/s: 182 .Deg C). This faster DHCV can be explained with the fact that Wolsung Unit-1 have been operated in a severe conditions(higher cooling water temperature, high power and efficiency) than Pickering one. The striation spacing which was seen ...
2003-10-01
Energy Technology Data Exchange (ETDEWEB)
The two tank (125,000kl each) foundations under construction are as large as 85m in diameter, and the north-side tank is to be placed over a sharper slope. The tanks are greatly different in their height from the rockbed since they are to be placed at the same level. For reduction in construction cost and time, a pile foundation design is chosen as the basic concept for foundation construction. After an overall evaluation of stability upon exposure to seismic torsion and of the deformation characteristics of piles and concrete slabs, a total pile foundation design with rock debris replaced with crushed rock is determined to be the design to be adopted. Since the piles to be driven in are greatly different in length, error in the pile supporting force will be too grave under the conventional pile landing control system. Therefore, a high-accuracy pile landing control system is employed, established after a rapid load test in addition to the dynamic load ...
1998-09-05
Corrosion probes for fireside monitoring in coal-fired boilers
Energy Technology Data Exchange (ETDEWEB)
Corrosion probes are being developed and combined with an existing measurement technology to provide a tool for assessing the extent of corrosion of metallic materials on the fireside in coal-fired boilers. The successful development of this technology will provide power plant operators the ability to (1) accurately monitor metal loss in critical regions of the boiler, such as waterwalls, superheaters, and reheaters; and (2) use corrosion rates as process variables. In the former, corrosion data could be used to schedule maintenance periods and in the later, processes can be altered to decrease corrosion rates. The research approach involves laboratory research in simulated environments that will lead to field tests of corrosion probes in coal-fired boilers. Laboratory research has already shown that electrochemically-measured corrosion rates for ash-covered metals are similar to actual mass loss corrosion rates. Electrochemical ...
2005-01-01
Constitutive modeling of a nickel base superalloy -with a focus on gas turbine applications
Energy Technology Data Exchange (ETDEWEB)
Gas turbines are used where large amounts of energy is needed, typically as engines in aircraft, ferries and power plants. From an efficiency point of view it is desirable to increase the service temperature as much as possible. One of the limiting factors is then the maximum allowable metal temperatures in the turbine stages, primarily in the blades of the first stage, that are exposed to the highest gas temperatures. Specially designed materials are used to cope with these severe conditions, such as the nickel base superalloy IN792. In order to be able to design the components for higher temperatures and tighter tolerances, a detailed understanding and computationel models of the material behaviour is needed. The models presented in this work have been developed with the objective of being physically well motivated, and with the intention of avoiding excessive numbers of parameters. The influence of the parameters should also be as easy as possible to interpret. ...
2003-05-01
Assessment of gas flammability in transuranic waste container
Energy Technology Data Exchange (ETDEWEB)
The Safety Analysis Report for the TRUPACT-II Shipping Package [Transuranic Package Transporter-II (TRUPACT-II) SARP] set limits for gas generation rates, wattage limits, and flammable volatile organic compound (VOC) concentrations in transuranic (TRU) waste containers that would be shipped to the Waste Isolation Pilot Plant (WIPP). Based on existing headspace gas data for drums stored at the Idaho National Engineering Laboratory (INEL) and the Rocky Flats Environmental Technology Site (RFETS), over 30 percent of the contact-handled TRU waste drums contain flammable VOC concentrations greater than the limit. Additional requirements may be imposed for emplacement of waste in the WIPP facility. The conditional no-migration determination (NMD) for the test phase of the facility required that flame tests be performed if significant levels of flammable VOCs were present in TRU waste containers. This paper describes an approach ...
1995-12-01
TPX Neutral Beam Injection System design
International Nuclear Information System (INIS)
The existing Tokamak Fusion Test Reactor Neutral Beam system is proposed to be modified for long pulse operation on the Tokamak Physics Experiment (TPX). Day one of TPX will call for one TFTR beamline modified for 1000 second pulse lengths oriented co-directional to the plasma current. The system design will be capable of accommodating an additional co-directional and a single counter directional beamline. For the TPX conceptual design, every attempt was made to use existing Neutral Beam hardware, plant facilities, auxiliary systems, service infrastructure, and control systems. This paper describes the moderate modifications required to the power systems, the ion sources, and the beam impinged surfaces of the ion dumps, the calorimeters, the various beam scrapers, and the neutralizers. Also described are the minimal modifications required to the vacuum, cryogenic, and gas systems and the major modification of replacing the beamline-torus duct ...
1993-10-11
Energy Technology Data Exchange (ETDEWEB)
The present study discusses the contribution of the adoption of more rigorous and objective criteria to the selection and analysis of information sources, leading to more scientific rigour when registering phytotherapic drugs. To this end, it is herein proposed the adoption of a previously tested and acknowledged methodology, namely the Systematic Revision, as a standard for phytotherapic drug analyses. In order to show differences brought about by the Systematic Revision during the registration procedures of phytotherapic drugs, the case of the Maytenus ilicifolia (known popularly in Brazil as 'espinheira-santa') is presented. As it is well known, the use of ionizing radiation is expanding, especially in medicine and pharmacy. Therefore, gamma radiation was applied to the microbiological quality control of phytotherapic matrices. Results indicated a positive contribution of Systematic Revision to the registration procedures of phytotherapic ...
2006-07-01
Study on upgrading of oil palm wastes to animal feeds by radiation and fermentation processing
International Nuclear Information System (INIS)
Upgrading of oil palm empty fruit bunch (EFB), which is a main by-product of palm oil industry, to animal feeds by radiation pasteurization and fermentation was investigated for recycling the agro-resources and reducing the environmental pollution. The following results were obtained: 1) The necessary dose for pasteurization of EFB contaminated by various microorganisms including aflatoxin producing fungi was determined as 10 kGy. The chemical and biological properties of EFB were changed little by irradiation up to 50 kGy. 2) In the fermentation process, Pleurotus sajor-caju was selected as the most effective fungi and the optimum condition for fermentation was clarified. The process of fermentation in suspension was also established for the liquid seed preparation. 3) The digestibility and nutritional value of fermented products were evaluated as ruminant animal feeds and the mushroom can be produced as by-product. 4) The pilot plant named Sterifeed was built at ...
2002-10-15
Status of he-cooled divertor development (PPCS subtask TW4-TRP-001-D2)
International Nuclear Information System (INIS)
Within the framework of the EU power plant conceptual study (PPCS), helium-cooled modular divertor concepts have been investigated in detail at the Forschungszentrum Karlsruhe during the past few years. The first conceptual design proposed was based on convective cooling with the use of flow promoters in the form of pin and/or slot arrays (HEMP/HEMS) to increase the cooling surface and, hence, enhance the heat transfer capacity. While continuing the design optimisation, an advanced multiple-jet design (HEMJ) was introduced, which is based on direct jet-to-wall impinging cooling and offers advantages in terms of simple construction and manufacturing. Main emphasis of the 2004 work program (TW4-TRP-001) lay on experiments for the concepts HEMJ and HEMS, which were mainly performed at the Efremov Institute in St. Petersburg, Russia. For experiment preparation, detailed test programs were worked out and accompanying CFD analyses were accomplished. ...
Energy Technology Data Exchange (ETDEWEB)
A characteristic trait of Francis turbines operating at low-head is pressure pulsations that occur during certain load levels of the generator. These stem from pressure variations across the turbine due to pulsating flow in the draft-tube. This surging action of the water column is related to draft-tube geometry and flow-rate of water in the penstock. The pressure pulsations cause torque variations on the turbine and corresponding electric power pulsations. If electric power is used as a feedback signal to the Power System Stabilizer (PSS), then Mvar and terminal voltage pulsations will occur when the generator is operating in the ``rough zone``. This paper describes field test results for investigating feedforward control from the penstock, draft tube and spiral case pressure to reduce the effects of Mw pulsations on PSS output signals. This investigation involved a PSS with generator power as the feedback signal and the PSS tuned for local and inter-area damping.
1993-12-01
Product yield and hydrogen consumption selectivity tests for coal-liquefaction-catalyst development
Because hydrogenation of coal to liquid products (oils) is accompanied by distributions of complex by-product mixtures (IOM, preasphaltenes, asphaltenes and gases) which change as a function of reaction variables (time, temperature and pressure) and reactor configuration, the determination of selectivity relationships for coal liquefaction catalysts has been a difficult and time-consuming task involving numerous experiments to adequately describe catalyst performance over a range of conditions. This paper describes a method for analyzing the experimental results of coal liquefaction reactions which may be applied to a number of aspects of coal liquefaction research and process control, including: rapid selectivity and performance screening for catalysts; correlation of laboratory results with process parameters; and optimization of product yield for plant process conditions. Catalyst selectivity and performance screening will be emphasized here. The approach to ...
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
Controls of welds by radiographies are an efficient non destructive technique but it can be dangerous if not managed following a strict set of rules. EDF acts to avoid risks via several ways (adapted tools, best practices) and seeks for an integration of the radiographies with respect to the other maintenance operations, in order to raise the ratio of availability of the electricity production unit. This study explores an original analysis of industrial radiography: the influence of the representations of the workplace and its utilizations. This document supports the utilization of some space constraints as explanations of difficulties in the industrial radiography activity. The document proposes innovative points of view coming for on-site observations and from a theoretical background 'cognitive sciences' completed by technical propositions. (author)
2008-07-15
Overview of Chuetsu-oki earthquake and evaluation of seismic safety
International Nuclear Information System (INIS)
The Chuetsu-oki Earthquake strongly shook the Kashiwazaki-Kariwa Nuclear Power Station with the ground motions exceeding the design values. The incidents include a fire breakout of the Unit 3 transformer, a release of spilled water containing small amount of radioactive materials to the non-radiation control area and subsequently to the environment at Unit 6, and a release of radioactive material from the main turbine condenser through the main stack of Unit 7 due to the delay stooping the turbine gland steam ventilator by the operator in manually, while every unit in operation was safety shutdown in the automatic mode ensuring the three fundamental safety functions of (a) reactivity control, (b) removal of heat from the core and (c) confinement of radioactive materials. Following integrity evaluation and performance testing of the overall plant, seismic safety of buildings, structures, equipment and pipelines on the basis of the basic ...
2010-07-01
Numerical Simulation and Analyses of the Loss of Feedwater Transient at the Unit 4 of Kola NPP
A three-dimensional numerical simulation of the loss-of-feed water transient at the horizontal steam generator of the Kola nuclear power plant is performed. Presented numerical results show transient change of integral steam generator parameters, such as steam generation rate, water mass inventory, outlet reactor coolant temperature, as well as detailed distribution of shell side thermal-hydraulic parameters: swell and collapsed levels, void fraction distributions, mass flux vectors, etc. Numerical results are compared with measurements at the Kola NPP. The agreement is satisfactory, while differences are close to or below the measurement uncertainties. Obtained numerical results are the first ones that give complete insight into the three-dimensional and transient horizontal steam generator thermal-hydraulics. Also, the presented results serve as benchmark tests for the assessment and further improvement of one-dimensional models of horizontal ...
2002-07-01
Natural circulation in FFTF, a loop type LMFBR
International Nuclear Information System (INIS)
The authors present a state-of-the-art review of natural circulation heat transfer in loop type reactor plants. Most of the examples are taken from Fast Flux Test Facility (FFTF) design experience, drawing on the authors' familiarity and a developing base of available documentation. On-going studies related to the Clinch River Breeder Reactor (CRBR) and some foreign experience are also noted where available in the literature. The emphasis is on the role of natural circulation in decay heat removal; however, free convection during either operation at power or normal shutdown does influence some aspects of the design and these are reviewed. In treating decay heat removal the topics discussed include steady state loop performance and transient dynamics for conditions immediately after scram and for the longer term which involves different considerations. The review summarizes complex dynamics, specific to the FFTF design evaluation, which ...
Energy Technology Data Exchange (ETDEWEB)
The primary objective of the project is to investigate the long-term effects of commercially available tangentially-fired low NO{sub x} combustion technologies on NOx emissions and boiler performance on Unit 2 at Gulf Power Company`s Plant Lansing Smith located near Lynn Haven, Florida. The project will characterize emissions and performance of a tangentially-fired boiler operating in the following configurations: Baseline ``as-found`` configuration: Phase 1; retrofitted low NO{sub x} concentric firing system (LNCFS) Level 2 and simulated low NO{sub x} bulk furnace staging (LNBFS): Phase 2; retrofitted low NO{sub x} concentric firing system (LNCFS) Level 3, Phase 3a and simulated LNCFS Level 1, Phase 3b.
1992-01-01
Hardening of ion-irradiated A533B steels investigated with nanoindentation technique
International Nuclear Information System (INIS)
Neutron irradiation embrittlement of reactor pressure vessel (RPV) steels is one of the critical issues on aging management for long term operation of nuclear power plants. Mechanistic understanding of embrittlement is a key to accurate prediction of embrittlement, especially after long term operation where the mechanical test data are sparse. Since matrix hardening is the source of the embrittlement, we focus on matrix hardening of A533B bainitic pressure vessel steel. Bainitic matrix is composed of lath structure made by ferrite and carbides, therefore it is important to understand how this structure affects hardening behavior, and to understand irradiation response of each phase. As the typical dimension of lath structure of A533B is about one micron, nanoindentation technique is suitable for the estimation of hardening of each phase. MV ion accelerators were used for controlled irradiation because MeV ion irradiation can produce defects to ...
2008-10-13
Fluid mixing in reactor containment
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: Hydrogen release and distribution in nuclear power plant containment is an important safety issue. Selection of a proper turbulence model is important for accurate estimation of the mixing process. The selection of turbulence model is dictated by the best compromise between accuracy and computational efforts. For this, three different turbulence models, viz. Standard k-{epsilon}, RNG k-{epsilon} and Reynolds Stress Model, based on Reynolds averaged Navier Stokes equations (RANS) approach, were used. The computations were done using the CFD code FLUENT, which is based on the control volume methodology. The computational results were compared with the experimental results of HYMIS test facility, where helium was used to simulate hydrogen. The processes of helium plume rise, multiple plume merging, distribution and mixing were studied. Based on these computations, a simple analytical/empirical zone based model was ...
2005-07-01
Fluid mixing in reactor containment
International Nuclear Information System (INIS)
Full text of publication follows: Hydrogen release and distribution in nuclear power plant containment is an important safety issue. Selection of a proper turbulence model is important for accurate estimation of the mixing process. The selection of turbulence model is dictated by the best compromise between accuracy and computational efforts. For this, three different turbulence models, viz. Standard k-#epsilon#, RNG k-#epsilon# and Reynolds Stress Model, based on Reynolds averaged Navier Stokes equations (RANS) approach, were used. The computations were done using the CFD code FLUENT, which is based on the control volume methodology. The computational results were compared with the experimental results of HYMIS test facility, where helium was used to simulate hydrogen. The processes of helium plume rise, multiple plume merging, distribution and mixing were studied. Based on these computations, a simple analytical/empirical zone based model was ...
2005-10-02
International Nuclear Information System (INIS)
Bobbin-coil-type eddy current probes, which are conventionally used for nondestructive inspection of steam generator tubes in pressurized-water-type nuclear power plants, have poor detectability for circumferential flaws. Hence a new type of eddy current probe was proposed to detect effectively the magnetic flux component disturbed by a flaw and thus to eliminate the flaw direction dependency on the flaw detectability. In the course of development of the proposed method, structures of the probe were investigated based on the measurement of magnetic fields induced by exciting flat coils with several shapes. The new type of probe proposed here consists of differential pick-up coils detecting magnetic flux and exciting coils having a parallelogrammic shape, and its structure was fabricated experimentally in order to detect flaws independently of their directions. Nondestructive flaw detection tests was then conducted by using the probe. The ...
1995-01-01
International Nuclear Information System (INIS)
The Swedish State Power Board has together with Nukem, Hanau, West-Germany carried out pyrolysis o powder resins in a pilot plant with a capacity of about 30 kg/hr. The pyrolysis reactor with its afterburner and offgas scrubber system has been operated under steady state condition. About 2200 kg resins have been pyrolysed under November-December 1983 and the decontamination factor for Cs has been measured. Solidification of the residues from the pyrolysis reactor and scrubber water solutions has been carried out and various recipes with cement have been tested. The pyrolysis process has high decontamination factors and no offgas problems as the operating temperature of the reactor is Low. The residues from the reactor are chemically dead and can not cause swelling problems. Compared with a normal cementation process the final waste volume will be reduced with a factor of 4 if also the scrubber water after neutralization is solidified. The ...
Energy Technology Data Exchange (ETDEWEB)
Red mud is a by-product of the alkaline extraction of aluminum from the bauxite and represents a renewed environmental problem due the significant annual throughput by the plants. In the present work, the pozzolanic properties of Brazilian red mud fired at 600, 700, 800 and 900 deg C were investigated by monitoring lime consumption using DTA analysis and Brazilian standard methodology NBR 5772 (1992). Products and kinetics of hydration were determined in cement pastes produced with 5 and 15% red mud using x-ray diffraction and DTA analysis. Compressive strength and capillary absorption tests were realized on mortars constituted by 5, 10 and 15% red mud in replacement of cement. When calcined at 600 deg C, the red mud develops good pozzolanic properties, and the compressive strength of mortars produced with this waste meet values in accordance with regulatory standard. These results shown than red mud can be used, in partial replacement of ...
2010-07-01
Evaluation of red mud as pozzolanic material in replacement of cement for production of mortars
International Nuclear Information System (INIS)
Red mud is a by-product of the alkaline extraction of aluminum from the bauxite and represents a renewed environmental problem due the significant annual throughput by the plants. In the present work, the pozzolanic properties of Brazilian red mud fired at 600, 700, 800 and 900 deg C were investigated by monitoring lime consumption using DTA analysis and Brazilian standard methodology NBR 5772 (1992). Products and kinetics of hydration were determined in cement pastes produced with 5 and 15% red mud using x-ray diffraction and DTA analysis. Compressive strength and capillary absorption tests were realized on mortars constituted by 5, 10 and 15% red mud in replacement of cement. When calcined at 600 deg C, the red mud develops good pozzolanic properties, and the compressive strength of mortars produced with this waste meet values in accordance with regulatory standard. These results shown than red mud can be used, in partial replacement of ...
2010-11-21
Estimating energy requirement in cashew (Anacardium occidentale L.) nut processing operations
Energy Technology Data Exchange (ETDEWEB)
This work deals with a study on estimation of energy consumption in eight readily defined unit operations of cashew nut processing. Data for analysis were collected from nine cashew nut mills stratified into small, medium and large categories to represent different mechanization levels. Series of equations were developed to easily compute requirements of electricity, fuel and labour for each of the unit operations. The computation of energy use was done using spreadsheet program on Microsoft Excel. The results of application test of the equations show that the total energy intensity in the cashew nut mills varied between 0.21 and 1.161MJ/kg. Electrical energy intensity varied between 0.0052 and 0.029MJ/kg, while thermal energy intensity varied from 0.085 to 1.064MJ/kg. The two identified energy intensive operations in cashew nut processing are cashew nut drying and cashew nut roasting, altogether accounting for over 85% of the total energy consumption in all the ...
2006-07-15
International Nuclear Information System (INIS)
A nitric acid solution containing Cr_2O_7"2"- ion is used for a corrosion test which simulates the condition in a nuclear fuel reprocessing plant. As the effect of Cr content on the corrosion resistance of stainless steel is not yet fully understood in that solution, the effects of Cr content in an alloy and that of Cr_2O_7"2"- ion in nitric acid on the corrosion rate were studied by using electro-chemical measurements. The increase of Cr content reduced the general corrosion rate in nitric acid solution without Cr_2O_7"2"- ion, however it increased that in nitric acid solution containing Cr_2O_7"2"- ion. It is considered that the reversal of the Cr content dependency is due to a rise of the corrosion potential caused by addition of Cr_2O_7"2"- ion to the potential region where a high Cr alloy shows higher anodic dissolution rate than a low Cr content alloy. (author).
Energy Technology Data Exchange (ETDEWEB)
The effect of steam explosion treatment on the enzymatic hydrolysis yield of two different lignocellulosic substrates is studied. Raw materials have been pretreated in a pilot plant designed to work in batch and equipped with a reactor vessel of 2 1 working volume where biomass was heated at the desired temperature and then exploded and recovered in a cyclone. Temperatures from 190 to 230 degree celsius and reaction times from 2 to 8 min. have been assayed. The efficiency of the steam explosion treatment has been evaluated on the composition of the lignocellulosic materials as well as on their enzymatic hydrolysis yield using a cellulolytic complex from T. reesel. Results show a high solubilization rate of hemicelluloses and variable losses of cellulose and lignin depending on the conditions tested. Enzymatic hydrolysis yields of both substrates experimented remarkable increments, corresponding the highest values obtained to 210 degree celsius; ...
1991-07-01
Effect of primary air content on formation of nitrogen oxides during combustion of Ehkibastuz coal
Energy Technology Data Exchange (ETDEWEB)
Investigations are discussed carried out in a pilot plant at the Kaz. Power Engineering Scientific Research Institute into the effect of the amount of primary air in coal-dust flame on the final concentration of nitrogen oxides in flue gases. The tests were carried out in a 7500 mm high, 1600 mm dia vertical cylindrical combustion chamber having type P-57 burner, and air dispersed fuel plus additional air supplies located at the top. Amounts of coal dust fed by a drum feeder along the air pipe varied from 100-600 kg/h. The required air was supplied by 5000 m/sup 3//h Type TK-700/5 blowers at 0.04 MPa. Ehkibastuz coal samples contained: 1.3% moisture; 48.1% ash; 38.02% carbon; 2.56% hydrogen; 0.73% sulfur; 0.60% nitrogen; heat of combustion was 14.3 MJ/kg. Results obtained indicate that variations in the amount of primary air in swirl flow burners affect formation of fuel nitrogen; there is an optimum volume at which minimum quantities of ...
1986-01-01
Development of modified 9 Cr-1 Mo steel for elevated-temperature service
International Nuclear Information System (INIS)
The status of development and commercialization of a modified 9 Cr-1 Mo alloy is presented. The alloy is modified by the addition of 0.06 to 0.10% Nb and 0.18 to 0.25% V. The alloy is recommended for use in the normalized and tempered condition (1040"0C for 1 h, air cooled to room temperature; 760"0C for 1 h, air cooled to room temperature). Heat treatment, Charpy impact, tensile, and creep properties of the alloy are described in detail along with a brief description of other properties. The modified alloy has creep strength that exceeds that of standard 9 Cr-1 Mo and 2 1/4 Cr-1 Mo steels for the temperature range from 427 to 704"0C. The total-elongation and reduction-of-area values for all test temperatures and rupture times up to 22,500 h exceed 15 and 70%, respectively. The estimated design allowable stresses for this alloy are higher than those for standard 9 Cr-1 Mo and 2 1/4 Cr-1 Mo steel. At 550"0C and above, these values are twice those of the other ...
1983-06-19
Development and manufacture of tritium-in-air monitors for Indian PHWRs
International Nuclear Information System (INIS)
Tritium, a beta emitting gas at room temperature causes a biological hazard in the locations where it is present beyond acceptable limits. The hazard can be due to inhalation, and absorption by skin. Hence is the necessity of Tritium monitoring instruments/systems for ensuring safety in the PHWRs and the nuclear research plants and laboratories. It is desirable that the instruments address satisfactorily to certain factors like the following: (i) Wide range of Tritium concentrations - 1 to 104 DAC ( Derived Air Concentration) (ii) On-line monitoring features (iii) Small response time (On-spot instantaneous measurements) (iv) Portability (v) Mitigation of memory effects. This paper presents an overview of the Online Tritium in Air Monitoring Systems manufactured by ECIL for Pressurised Heavy Water Reactors at Tarapur, Kaiga, and Rawatbhata. Significant aspects of design, function, testing, limitations of the detectors and electronics and the ...
2009-10-01
British Library Electronic Table of Contents (United Kingdom)
Genetic analysis of resistance of plant introduction (PI) 438489B to soybean cyst nematode (SCN) have shown that this PI is highly resistant to many SCN HG types. However, validation of the previously detected quantitative trait loci (QTL) has not been done. In this study, 250 F2:3 progeny of a Magellan (susceptible)??PI 438489B (resistant) cross were used for primary genetic mapping to detect putative QTL for resistance to five SCN HG types. QTL confirmation study was subsequently conducted using F6:7 recombinant inbred lines (RILs) derived from the same cross. Simple sequence repeat (SSR) and single nucleotide polymorphism (SNP) markers were employed for molecular genotyping. Interval mapping (IM), permutation tests, cofactor selection, and composite interval mapping (CIM) were performe...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Factors important in choosing between process concepts were mechanical complexity and amenability to scale-up studies. The culmination of this work was a process concept known as Staged Turbulent Bed Retorting Process (STB), which has now been tested in pilot plants. Operating conditions are described. The environment in the retort section can be described as a staged, moving bed of particles, in which a portion of the particles are fluidized at gas velocities well below minimum fluidization velocity of many of the particles. Research and engineering evaluations have established that the STB provides prospects for the responsible development of oil shale resources on a commercial scale. A 320 ton/d semiworks unit, the next technological step, will be commissioned shortly. This unit will be large enough to provide scale-up data for design of modules and to demonstrate the entire process, generating data needed to optimize, design, and construct ...
1982-03-01
International Nuclear Information System (INIS)
Macroinvertebrate communities in Rietvlei nature reserve wetland area and their relationship with water quality were studied with the aim to evaluate their use as potential indicators of pollution. Sampling locations were selected to include outlets from swage effluent, agricultural and informal residential runoff. A large increase in nutrient concentrations was observed downstream from discharged treated sewage with an associated decrease in species richness. Bioassays performed included: Daphnia magna, Hydra attenuate, Lactuca sativa, Allium cepa and Pyxicephalus adspersus. The highest percentage of lethality response to a screen (100% concentration) of sampled wetland water by test specimens were observed at the point source input of the Hartbeespoort treated sewage plant. Data generated from the AUSRIVAS method and multitrophic level bioassays revealed the deterioration of the wetland possibly due to factors such as increasing urbanization, ...
2008-11-01
Behavior of ice covers subjected to large daily flow and level fluctuations
Energy Technology Data Exchange (ETDEWEB)
The stability of a solid ice cover subjected to rapidly varying water levels and discharge was investigated. The support from the bank limits the stress in the ice cover and consequently bank contact must be maintained to ensure ice cover stability. An analysis was required of the stability of ice hinges, a flexible connection between a solid ice cover and the riverbank. Phase II and phase III of the research involved a field study of the Peace River, investigating the evolution of ice hinges with water level variation, from initial ice cover cracking parallel to the banks, to a fully developed hinge. A test program of midwinter discharge variations was undertaken to gather specific data and measurements of ice hinge link length, ice thickness, hinge joint behavior, riverbank geometry, and response of ice hinging to water level variation. As a result of the program, concepts developed throughout the study were confirmed, preliminary guidelines for hydroelectric ...
1984-11-01
Application od scaling technique for estimation of radionuclide inventory in radioactive waste
International Nuclear Information System (INIS)
Safety studies related to the disposal of low- and intermediate waste indicate that the long term risk is determined by the presence of long-lived nuclides such as "1"4C, "5"9Ni, "6"3Ni, "9"9Tc, "1"2"9I and the transuranium elements. As most of these nuclides are difficult to measure, the correlation between these critical nuclides and some other easily measurable key nuclides such as "6"0Co and "1"3"7Cs has been investigated for typical waste streams of Paks Nuclear Power Plant (Hungary) and scaling factors have been proposed. An automated gamma-scanning monitor has been purchased and calibrated to determine the gamma-emitting radionuclides. Radiochemical methods have been developed to determine significant difficult-to-measure radionuclides. The radionuclides of interest have been "3H, "1"4C, "9"0Sr, "5"5Fe, "5"9Ni, "9"9Tc, "1"2"9I and TRUs. The measurements taken so far have revealed brand new information and data on radiological composition of waste of ...
1996-09-16
An overview of PETC`s gas-to-liquids technology R&D Program
Energy Technology Data Exchange (ETDEWEB)
The overall goal of the Gas-to-Liquids Program at the U.S. Department of Energy`s Pittsburgh Energy Technology Center (PETC) is to develop technologies for the production of hydrocarbon fuels and premium chemicals from light alkane gases. PETC`s current Gas-to-Liquids Program comprises the development of four primary advanced conversion technologies, namely, partial oxidation, oxidative coupling, oxyhydrochlorination, and novel conversion processes. Based on the current state of development, it can be concluded that, in the near future, one or more of these technologies will reach proof-of-concept demonstration. Oxyhydrochlorination is the most advanced direct conversion technology, and the synthesis of lower cost methyl chloride from natural gas would impact several commercial technologies that utilize methyl chloride as an intermediate to high value products. Technology development for the partial oxidation of methane to synthesis gas using ceramic membranes could result in ...
1995-04-01
An Experimental study on a Method of Computing Minimum flow rate
International Nuclear Information System (INIS)
Many pump reliability problems in the Nuclear Power Plants (NPPs) are being attributed to the operation of the pump at flow rates well below its best efficiency point(BEP). Generally, the manufacturer and the user try to avert such problems by specifying a minimum flow, below which the pump should not be operated. Pump minimum flow usually involves two considerations. The first consideration is normally termed the 'thermal minimum flow', which is that flow required to prevent the fluid inside the pump from reaching saturation conditions. The other consideration is often referred to as 'mechanical minimum flow', which is that flow required to prevent mechanical damage. However, the criteria for specifying such a minimum flow are not clearly understood by all parties concerned. Also various factor and information for computing minimum flow are not easily available as considering for the pump manufacturer' proprietary. The objective of this study is to obtain ...
2009-10-01
Active biomonitoring of heavy metal pollution using Rosa rugosa plants
Energy Technology Data Exchange (ETDEWEB)
The purpose of this work was to evaluate the quality of a rural area near Faenza (Italy) by using an active biomonitoring approach, i.e., by placing homogeneous individuals of the perennial shrub Rosa rugosa in different sites throughout the area. Further sites, within the city or its environs, were used for comparison. Soil and leaves of R. rugosa were analyzed for their heavy metal content. The total heavy metal pattern of leaves closely paralleled the pattern registered in soil, with the highest content (both in total and assimilable forms) at the site in the urban area, which is exposed to heavy traffic. Pollen quality (abortiveness and viability) was also tested as a potential indicator of pollution. Pollen abortiveness was strictly related to Pb levels in leaves, while viability was inversely related to leaf Cr content. Our results suggest that R. rugosa has the potential to be a good biomonitoring system. - Rosa rugosa leaves and pollen are - to different ...
2007-09-15
Active biomonitoring of heavy metal pollution using Rosa rugosa plants
International Nuclear Information System (INIS)
The purpose of this work was to evaluate the quality of a rural area near Faenza (Italy) by using an active biomonitoring approach, i.e., by placing homogeneous individuals of the perennial shrub Rosa rugosa in different sites throughout the area. Further sites, within the city or its environs, were used for comparison. Soil and leaves of R. rugosa were analyzed for their heavy metal content. The total heavy metal pattern of leaves closely paralleled the pattern registered in soil, with the highest content (both in total and assimilable forms) at the site in the urban area, which is exposed to heavy traffic. Pollen quality (abortiveness and viability) was also tested as a potential indicator of pollution. Pollen abortiveness was strictly related to Pb levels in leaves, while viability was inversely related to leaf Cr content. Our results suggest that R. rugosa has the potential to be a good biomonitoring system. - Rosa rugosa leaves and pollen are - to different ...
2007-09-01
Energy Technology Data Exchange (ETDEWEB)
Today`s nuclear power plants are marked by increasing needs for non-destructive inspection techniques in preventive maintenance programs. Additionally, it is becoming more important to evaluate residual stress which may be a key parameter for crack propagations in welded pipings. The authors have developed an ultrasonic velocity measurement method which obtains ultrasonic velocity changes by residual stress with a high accuracy. The ultrasonic velocity measurement is composed of three procedures. They are as follows. (1) Highly accurate propagation time measurements; (2) Pipe thickness correction; (3) Residual stress evaluation. The ultrasonic velocity measurements have been applied to the residual stress evaluation of carbon steel welded pipings. Destructive testing using stress strain gauges was done after the ultrasonic non-destructive evaluation of the residual stress. The experimental results verified that residual stress in carbon steel ...
1995-08-01
Energy Technology Data Exchange (ETDEWEB)
Transition joints in power plants between ferritic steels and austenitic stainless steels suffer from a mismatch in coefficients of thermal expansion (CTE) and the migration of carbon during service from the ferritic to the austenitic steel. To overcome these, nickel-based consumables are commonly used. The use of a trimetallic combination with an insert piece of intermediate CTE provides for a more effective lowering of thermal stresses. The current work envisages a trimetallic joint involving modified 9Cr-1Mo steel and 316LN austenitic stainless steel as the base materials and Alloy 800 as the intermediate piece. Of the two joints involved, this paper describes the choice of welding consumables for the joint between Alloy 800 and 316LN. Four consumables were examined: 316, 16-8-2, Inconel 82 and Inconel 182. The comparative evaluation was based on hot cracking tests and estimation of mechanical properties and coefficient of thermal expansion. ...
2000-03-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
