WorldWideScience
 
 
1

Measurement of energy expenditure in overweight men and women using [C-14]-bicarbonate-urea before and after weight loss  

International Nuclear Information System (INIS)

Full text: Many studies have demonstrated significant declines in 24-hour energy expenditure (TEE) measured by whole body calorimetry with either the process of weight loss or the maintenance of reduced body weight. The aims of this study were to determine the effect of weight loss and two weeks of weight maintenance on TEE using ["1"4C]-bicarbonate-urea, Eleven subjects (6 males, 5 females), mean (#+-#SE) age 50 #+-# 3 years, BMI 34.1 #+-# 2.1 kg/m2 and body fat 38.7 #+-# 3% were studied before and after a decrease in body weight of > 8% over a period of 8 weeks, followed by two weeks of weight maintenance. Weight loss was induced using the combination of Modifast and one small meal a day (#approx#3.34 MJ/day). Body composition (DEXA), resting energy expenditure (REE) and the thermic effect of a 2.7 MJ test meal (TEF) were measured in addition to TEE at week 2 and again at week 12. Diet was assessed using diaries and ...

2002-05-04

2

LES benchmark study of high cycle temperature fluctuations caused by thermal striping in a mixing tee  

Energy Technology Data Exchange (ETDEWEB)

Thermal striping is identified as one of the causes of thermal fatigue failure in nuclear power plants. Numerical studies of thermal striping require three-dimensional, unsteady turbulent modeling that resolves both large and small-scale turbulent motions. Benchmark studies were carried out using the LES turbulence model solved by the commercial CFD code FLUENT. Two types of mixing tee configurations were modeled to evaluate the performance of the CFD code. The simulation results presented in normalized average temperature and normalized fluctuating temperatures are in good agreement with measurements.

2006-02-15

3

Contribution to the compensation of extra high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

An improved method to design suitable compensating schemes for extra high voltage transmission lines is presented. The technique is general and effective and will greatly facilitate the design of the optimal compensation scheme for extra high voltage transmission lines. The technique is illustrated for a typical 500 kV system. The equations developed here for voltage maxima and minima along the transmission line eliminate the need for point-to-point computation of the voltage profile. The controversy existing in the literature over the problem of making a choice between pi and tee configurations has been removed and it is established with a mathematical proof that the tee configuration requires compensating elements of lower ratings.

1987-04-01

4

Dietary energy requirements of young adult men, determined by using the doubly labeled water method  

International Nuclear Information System (INIS)

The autors examined the hypothesis that current recommendations on dietary energy requirements may underestimate the total energy needs of young adult men, by measuring total energy expenditure (TEE) and resting energy expenditure (REE) in 14 weight-maintaining healthy subjects leading unrestricted lives. TEE and body composition were measured by using 2H(2)18O, and REE was measured by using indirect calorimetry. All subjects had sedentary full-time occupations and participated in strenuous leisure activities for 34 #+-# 6 (SE) min/d. TEE and REE were 14.61 #+-# 0.76 and 7.39 #+-# 0.26 MJ/d, respectively, and 202 #+-# 2 and 122 #+-# 2 kJ.kg-1.d-1. There were significant relationships between TEE and both body fat-free mass (r = 0.732, P less than 0.005) and measured REE (r = 0.568, P less than 0.05). Measured TEE:REE values were significantly higher than the recommended energy ...

5

Intracardiac Echocardiography: A New Guiding Tool for Transcatheter Aortic Valve Replacement  

British Library Electronic Table of Contents (United Kingdom)

BackgroundEchocardiography has been debated as an adjunct for transcatheter aortic valve replacement (TAVR). The aim of this prospective study was to comparatively evaluate intraprocedural guidance using intracardiac echocardiography (ICE) and transesophageal echocardiography (TEE). MethodsFifty high-risk patients with severe aortic stenosis scheduled for TAVR were randomized to either guidance using ICE (group 1; n = 25) or monitoring using TEE (group 2; n = 25). ResultsIn contrast to TEE, ICE allowed continuous monitoring. The need for probe repositioning during the procedure was much lower in group 1 (0.1 +- 0.3 vs 5.7 +- 0.7 maneuvers, P P = .003). Both coronary ostia were more frequently visualized in group 1 (18 vs 2 cases, P n = 25, r2 = 0.90, P n = 11, P = .012), but ICE did not (m...

2011-01-01

6

Transesophageal echo to help percutaneous closure of ventricular septal defect post acute myocardial infarction  

British Library Electronic Table of Contents (United Kingdom)

Ventricular septal defect after acute myocardial infarction (AMI) is a complication associated with poor outcome in the absence of intervention. We report a case of successful TEE guided transcatheter closure of a post myocardial infarction (MI) ventricular septal defect (VSD) with an Amplatzer occluder in a 79 years old male with cardiogenic shock.

2011-01-01

7

Prevent Diabetes Problems: Keep Your Heart and Blood Vessels Healthy  

Science.gov (United States)

... mini-stroke," also called a TIA or a transient ischemic attack . If you have any of these warning signs, ... ur-uhl) (ar-TEE-ree-uhl) (dih-ZEEZ) transient ischemic attack (TRANZ-see-uhnt) (iss-KEE-mik) (uh-TAK) [ ...

8

Pipework design and operation  

Energy Technology Data Exchange (ETDEWEB)

This book presents the proceedings of a conference dedicated to the design and operation of pipework in all its aspects, involving both metallic and non-metallic materials. Topics considered include a study of single mitre pipe bends using the finite element method; tests to failure of GRP pipe bends under in-plane flexural loading; finite element stress analysis of an equal diameter branch pipe intersection subjected to internal pressure and in-plane moment loadings; finite element stress analysis of extruded outlet tee junctions; design of pipework on the British PWR; a review of advanced remanent life methods for pipes operating in the creep range; pipe whip analysis and design; damping values for piping systems; pipework snubbers based on electro-rheological fluids; and the seismic design of piping systems in the flexible range.

1985-01-01

9

Measurement of induced radioactivity in materials found around a neutron generator  

Science.gov (United States)

The induced radioactivity in the construction materials of a Cockcroft-- Walton type neutron generator was measured. Major activation products (/sup 24/ Na, /sup 28/Al, /sup 56/Mn, /sup 64/Cu, /sup 65/Ni, /sup 69m/Zn, /sup 88/Rb /sup 91/Sr /sup 101/Mo, /sup 187/W/ and resulting doses are tabulated. Results show that the highest gamma activities would be observed in the fluorescent bulbs, copper pipe, aluminum lattice rod, and the aluminum pipe clamp. Thermoluminescent dosimeter readings yield the highest doses for the copper pipe tee, copper pipe, and aluminum lattice rod. Results of measuremerts of the neutron and gamma dose profiles of the facility are shown. However the indication is clearly that the tritium target, compared to other components, is the major source of radiation both during and after shutdown. (UK)

1974-01-01

10

Aortic non communicating dissections. A study with helical CT  

International Nuclear Information System (INIS)

The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at baseline CT and had low ...

2000-09-01