Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available
The authors report the findings of Aicardi syndrome, a disease of unknown etiology composed of multiple spasms, chorioretinal lacunae and agenesis of the corpus callosum. They present a case of Aicardi syndrome with characteristic clinical presentation and magnetic resonance imagingfindings. The disease, despite being considered rare, has characteristic imagingfindings. Over the past years magnetic resonance imaging has improved its ability in demonstrating other findings besides agenesis of the corpus callosum, making the radiologist's role very important in the diagnostic suspicion of this disease. (author)
Neuroepithelial cysts are rare and mostly asymptomatic cerebrospinal fluid (CSF)-like cysts. We describe herein the imagingfindings in five patients with neuroepithelial cysts. Two cases of proven and three of presumed neuroepithelial cysts are presented. Three of five are located in the thalamus, a location which is not characteristic for neuroepithelial cysts. In the case of incidental finding of asymptomatic neuroepithelial cyst, clinical and radiological follow-up is indicated and surgical intervention is not necessarily warranted. (orig.) With 5 figs., 6 refs.
The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imagingfindings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)
A 65-year-old woman who was diagnosed as having psoitis by CT findings, which disclosed non-symmetrical dilation of the psoas muscle and gaseous image. Pus from the psoas muscle seen at surgery corresponded to CT findings. Preoperative CT examination was useful in the establishment of diagnosis. (Namekawa, K.).
Background/Objective:Tarlov cysts or spinal perineurial cysts are uncommon lesions. These are mostly incidental findings on magnetic resonance imaging or myelograms. The...Full Text Available
The MRI's of 16 patients with either primary or secondary lymphatic disorders are evluated and the findings are compared to those from lymphangioscintigraphy or surgery. (author).
Peripheral primitive neuroectodermal tumors (peripheral PNETs) are rare in the abdomen. We report the imagingfindings of four peripheral PNETs arising in the abdomen. Three were ill-demarcated tumors and one was a well-demarcated tumor, with extensive local invasion and lymph node metastasis in two cases, respectively. The tumors are of inhomogeneous attenuation and heterogeneous enhancement after intravenous administration of contrast materials. Although their imaging manifestations cannot distinguish them from other sarcomas, recognition of these imaging features may be helpful in suggesting the possibility of peripheral PNETs in some cases.
Purpose Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. Methods We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. Results In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. Conclusion 3D-MDCT imag...
The "1"3"1I-labelled monoclonal antibodies 791T/36 and 79IT/36 Fab fragments have been evaluated in the imaging of patients with colorectal cancer, with benign colorectal tumours, and with malignant tumours of other parts of the gastrointestinal tract. The results of clinical imaging have been carefully correlated with clinical findings and direct measurement of the preferential uptake of antibody by the tumours. (UK).
/sup 99m/Tc biliary imaging was performed on a 34-year-old woman who was being investigated for suspected cholelithiasis. A left-sided liver was detected. On subsequent radionuclide imaging, partial visceral situs inversus and asplenia were demonstrated. Extensive roentgenographic investigation, ECG, echocardiogram, and laparotomy confirmed the radionuclide findings. Asplenia syndrome may exist without cardiovascular abnormalities and thus be undiscovered. Radionuclide imaging is important in the diagnosis of this syndrome.
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes. (orig.).
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
Paroxysmal nocturnal hemoglobinuria (PNH) is a rare, acquired disease involving multiple hematopoietic cell lines. Characteristics of PNH are intrinsic hemolytic anemia, iron deficiency anemia and venous thrombosis. We report a case of PNH with characterostoc MR and CT findings. The signal intensity of renal cortex was lower than that of medulla on both T1-and T2-weighted MR imaging. On T2 weighted MR images, the liver showed very low signal intensity but the signal intensity of the spleen was normal. On precontrast CT the attenuation of renal cortex was higher than that of renal medulla and the attenuation of liver was higher than that of the spleen. These findings of MR imaging and CT were the result from the deposition of hemosiderin in the cells of proximal convoluted tubules and transfusional hemosiderosis of liver.
Ewing's sarcoma is a malignant bone tumor that can occur anywhere in the body, but it is most commonly observed in the long bones of the arms and legs, the pelvis and in the chest. The predominant sites of metastasis include the lung (38%), bone (including the spine; 31%), and the bone marrow (11%). Metastasis of Ewing's sarcoma to the central nervous system (CNS) is relatively rare, and most of the previous reports have demonstrated involvement of the bony calvarium or brain parenchyma. We describe here the imagingfindings of dural metastasis of Ewing's sarcoma, and these imagingfindings have not been previously reported on in the medical literature. In conclusion, dural metastasis of Ewing's sarcoma is very rare and its imaging characteristics are similar to those of a primary tumor, which mimic the findings of a schwannoma or meningioma. Despite its rarity, ...
Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...
Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor
We report the delayed sequelae arising in a case of electrical injury, reviewing the literature on the subject and focusing on the MRI findings of the brain. A 23-year-old male suffered burns to the left parietal scalp, both feet, and the anterior chest wall. Neurological symptoms and MRI abnormalities appeared 14 days after the insult and continued for about three months. T1-weight MR images demonstrated homogeneous hypointensity, while T2-weighted images depicted hyperintense finger-like projections. Contrast-enhanced T1-weighted images demonstrated strong band-like enhancement, indicating meningeal hyperemia. Follow-up MR imaging showed that the lesion had disappeared, indicating that the cerebral edema and meaningeal hyperemia were reversible.
We report here a case of a pathologically proven solitary fibrous tumor of the pancreas. A 54-year-old man was referred to our hospital for further evaluation of a pancreatic mass that was found incidentally....Full Text Available
Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available
Pericardial fat necrosis is an infrequent cause of acute chest pain and this can mimic acute myocardial infarction and acute pericarditis. We describe here a patient with the magnetic resonance imaging...Full Text Available
Membranous dysmenorrhea is an unusual clinical entity. It is characterized by the expulsion of huge fragments of endometrium during the menses, favored by hormonal abnormality or drug intake. This report describes a case with clinical, US, and MRI findings before the expulsion. Differential diagnoses are discussed. (orig.)
We report here on a case of localized lymphoid hyperplasia of the pancreas in a 70-year-old man which manifested as double lesions (uncinate process and tail) in the organ. The lesions were incidentally...Full Text Available
Colorectal cancer is extremely rare in children. We report a case of a 12-year-old boy who presented with a five-month history of weight loss and anorexia, associated with vomiting episodes, dizziness,...Full Text Available
Autoimmune pancreatitis (AIP) is a rare cause of recurrent acute pancreatitis or chronic pancreatitis in middle-aged patients, and is characterised by a marked infiltration of lymphocytes and plasma...Full Text Available
We report here the imagingfindings of a rare case of a lethal form of Gorham disease in a young female patient. Multimodality imagingfindings over 13 year-follow-up demonstrated progressive wide spread skeletal and soft tissue abnormalities with permeative osteolysis, pathological fractures and severe skeletal deformities. Unusual extensive osseous and soft tissue pneumatosis was illustrated on cross-sectional studies. The progressive nature of this form of Gorham disease and the subsequent complications eventually culminated in patient's death. (orig.)
We report here the imagingfindings of a rare case of a lethal form of Gorham disease in a young female patient. Multimodality imagingfindings over 13 year-follow-up demonstrated progressive wide spread skeletal and soft tissue abnormalities with permeative osteolysis, pathological fractures and severe skeletal deformities. Unusual extensive osseous and soft tissue pneumatosis was illustrated on cross-sectional studies. The progressive nature of this form of Gorham disease and the subsequent complications eventually culminated in patient's death. (orig.)
Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ...
Ewing's sarcoma and Triton's tumor are two uncommon bone tumors of the skull that have nonspecific clinical and imaging features. However, imaging methods are important in the detection of the lesions during the diagnostic investigation in order to evaluate the extent of the bone lesions, involvement of the soft tissues and brain, and to determine the presence of local recurrence and metastases. The confirmatory diagnosis relies on histological studies and immunohistochemistry. The authors report two cases of patients with these tumors and present the radiological findings. (author)
Primary Ewing's sarcoma of the skull is a very rare entity. We report MRI findings in a case of Ewing's sarcoma of the greater wing of sphenoid in a 4-year-old patient. Magnetic resonance imaging showed markedly heterogenous signal intensity with areas of haemorrhage and necrosis. It also demonstrated the exact extent of tumour due to its multiplanar capabilities and was, therefore, helpful in planning surgery. Copyright (2002) Blackwell Science Pty Ltd
The intrasphenoid form of basal cephalocele is uncommon. We describe the clinical, CT and MRI findings in two cases presenting in middle age with persistent cerebrospinal fluid rhinorrhoea. Emphasis is placed upon the imagingfindings which aid in discrimination of intrasphenoidal cephalocele from more common causes of a sphenoid sinus mass. (orig.)
We describe a closed-loop brain-computer interface that re-ranks an image database by iterating between user generated 'interest' scores and computer vision generated visual similarity measures. The interest scores are based on decoding the electroencephalographic (EEG) correlates of target detection, attentional shifts and self-monitoring processes, which result from the user paying attention to target images interspersed in rapid serial visual presentation (RSVP) sequences. The highest scored images are passed to a semi-supervised computer vision system that reorganizes the image database accordingly, using a graph-based representation that captures visual similarity between images. The system can either query the user for more information, by adaptively resampling the database to create additional RSVP sequences, or it can converge to a 'done' state. The done state includes a ...
We present a case of cerebral aspergillosis in an immunocompetent patient. The MRI signal characteristics were compared with the histologic findings. Irregular low-signal zones were demonstrated between the wall of the abscess and the central necrosis on T2-weighted images; the pathology specimen revealed concentrated iron in these transitional zones but no hemosiderin. Iron is an essential element for the growth of fungal hyphae. The low-signal zones may represent the areas where there was active proliferation of aspergillus, and the unique location of the low signal may be a helpful imaging characteristic for the diagnosis of an aspergillus abscess. (orig.)
This study was designed to evaluate early parenchymal changes of acute cerebral is chemia/infarct by using T2-weighted, diffusion-weighted, and calculated apparent diffusion coefficient(ADC) MR imaging. The brain MR images were successfully obtained 30, 60, 90, 120, 150 and 180 minutes after intraarterial administration of Lipiodol (0.4-0.6ml) into the common carotid artery in 10 of 11 cats (91%). T2-and diffusion-weighted images and ADC were analyzed and compared with histopathologic findings. High signal intensity on T2-weighted and diffusion-weighted images was found in one cerebral hemisphere 30 minutes after Lipiodol injection, which tended to increase with time until 3 hours. Subcortical white matter showed higher signal intensity than cortical gray matter since 30 minutes after embolization. ADC images showed decreased signal intensity in the embolized ...
The measurement of q{sub o} is extremely important for understanding the quantity of matter in our universe. The measurement of q{sub o} using supernovae of type Ia as standard candles is appealing because it requires less modeling than other methods using galaxies. The challenge with using supernovae to measure q{sub o} is in finding enough of them. In order to find supernovas, we have constructed a very popular f/1 camera for the 3.9m Anglo-Australian Telescope. The camera uses reducing optics that put a 17 in. {times} 17 in. field on a 1024 {times} 1024 pixel Thomson CCD. Using this system, we image to 23rd magnitude in five minutes. We have developed a software package that uses image subtraction to find supernovae that are approximately magnitude 22.4 or brighter in these images. One field can be processed every 6.6 minutes on a relatively unloaded VAX ...
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR ...
More than 660 synthetic aperture radar (SAR) images acquired over the southern Baltic Sea, the North Sea, and the Gulf of Lyon in the Mediterranean Sea by the Second European Remote Sensing Satellite (ERS-2) have been analyzed since December 1996 with respect to radar signatures of marine pollution and other phenomena causing similar signatures. First results of our analysis reveal that the seas are most polluted along the main shipping routes. SAR images acquired during descending (morning) and ascending (evening) satellite passes show different percentages of oil pollution, because most of this pollution occurs during night time and is still visible on the SAR images acquired in the morning time. Moreover, we found a higher amount of oil spills on SAR images acquired during summer (April-September) than on SAR images acquired during winter (October-March). We attribute this ...
To assess the potential of CT in evaluating the histological severity of acute appendicitis in comparison with surgical and pathological findings. The CT images of 75 patients with surgically proven appendicitis, including 10 cases of catarrhal, 34 of phlegmonous, and 31 of gangrenous appendicitis, were retrospectively analyzed for the following five CT findings: hazy periappendiceal densities, enlarged appendix, increased enhancement of the appendiceal wall, increased enhancement of the periappendiceal intestinal wall, and deficiency of the appendiceal wall. By comparing all the CT findings and the pathological severity of appendicitis (catarrhal, phlegmonous, and gangrenous), the prevalence of the five CT findings was calculated for each pathological category. Abnormal CT findings were noted in only one case of catarrhal appendicitis. Increased enhancement of ...
In the 21st century, Aerial and satellite images are information rich. They are also complex to analyze. For GIS systems, many features require fast and reliable extraction of open space area from high resolution satellite imagery. In this paper we will study efficient and reliable automatic extraction algorithm to find out the open space area from the high resolution urban satellite imagery. This automatic extraction algorithm uses some filters and segmentations and grouping is applying on satellite images. And the result images may use to calculate the total available open space area and the built up area. It may also use to compare the difference between present and past open space area using historical urban satellite images of that same projection
Ten patients with traumatic femoral neck fracture were studied with MR imaging (0.5 T, Magnetom, Siemens): unenhanced (multiecho, TR/TE = 1,600/30--240 [repetition time/echo time, msec]; gradient echo, TR/TE = 315/14, #theta# = 90 degrees) and Gd-DTPA enhanced (0.1 mM/kg body weight, Magnevist, Schering; gradient echo, TR/TE = 315/14, #theta# = 90 degrees). MR images were compared with clinical-radiographic findings. Digital subtraction angiography of the femoral head (FH) in five patients showed complete interruption of blood supply to the FH in three patients (signal intensity of FH did not increase on postcontrast images) and intact FH arteries in two patients (FH signal increased on postcontrast images, as did the healthy-side signal).
Objective: To compare the histopathology of nodular fasciitis (NF) with the magnetic resonance imaging (MRI) findings in order to evaluate the basis of the MR signal characteristics. Design and patients: Ten patients with NF, nine females and 1 male, with an age ranging from 13 to 58 years (mean 26.8 years) were studied. MRI findings, available in all 10 patients, were compared with the histopathology in nine patients, and an area-to-area comparative study of the whole specimen section histopathology and MRI was performed in two patients. Results: On the basis of an excisional biopsy or resection specimen, the nine lesions were classified into myxoid (n=4), cellular (n=3) and fibrous (n=2) subtypes. Four myxoid lesions with a subcutaneous location showed a homogeneous SI comparable with muscle on T1-weighted images, high SI on T2-weighted images, and had homogeneous enhancement. One ...
Leukodystrophies are inherited white matter diseases due to abnormalities occurring in myelin synthesis and/or maintenance. The most common types of these rare childhood conditions are represented by adrenoleukodystrophy, metachromatic leukodystrophy, Canavan's, Alexander's, Krabbe's, and Pelizaeus-Merzbacher's diseases. Most of them are lethal during childhood, with the exception of the adrenoleukodystrophy-adrenomyeloneuropathy complex, which sometimes, during its early phases, may be cured with a dietary therapy. The aims of this paper are: 1) the description of inheritance factors, pathogenesis, pathological and clinical findings of each of the most frequent childhood leukodystrophies; 2) the description of the most common patterns of these conditions on CT and MR imaging; 3) the evaluation of the diagnostic capabilities of these two imaging techniques and the comparison of their results. Finally, some of the therapies ...
To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined ...
Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo ...
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image ...
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all ...
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all ...
The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral ...
Brain MRI was carried out in patients with chronic liver diseases. No abnormal findings were recognized in patients with chronic viral hepatitis, while 59.2% of cirrhotics showed a symmetrically strong signal in basal ganglia on T1 weighted image in MRI. This finding significantly related with lowered Fischer`s ratio of serum amino acid, increased levels of serum phenylalanine, tyrosine and hyaluronic acid, prolonged prothrombin time and decreased platelet counts in the peripheral blood. Overt hepatic encephalopathy was observed in 6 of 34 patients with the strong signal in MRI during follow-up period, while none of patients without that finding developed hepatic encephalopathy. These results have indicated that the strong signal in basal ganglia on MRI appears in cirrhotic patients with severe liver dysfunction, and it is an useful index in the early diagnosis of latent hepatic encephalopathy. An ...
MRI (Magnetic resonance imaging) has been widely used in the diagnosis of primary carpal tunnel syndrome (CTS). However, it has had limited clinical application in diagnosing persistent or recurrent CTS. We aimed to investigate the efficacy of this imaging modality in patients who had previously undergone open carpal tunnel release without relief of symptoms, and assess the correlation of MRI with intra-operative findings upon re-exploration. MRI studies were performed on 17 wrists (16 patients) presenting with recurrent/persistent symptoms and signs of CTS in whom repeat nerve conduction studies were also performed. Surgical re-exploration was undertaken on 16 wrists in which a 100% correlation was noted between MRI and intra-operative findings of an incompletely released or re-grown tran...
MRI findings in 13 patients with monolateral parotid tumor were compared with US, sialographic and CT findings. MRI did not allow an accurate diagnosis in 2 patients with diffuse chronic parotitis. MRI was superior to CT in 1 case in defining the intraglandular site of the lesion, and in 2 patients in showing the extraglandular involvement. MRI proved to be superior to CT thanks to its contrast resolution and to multiplanar imaging. MRI high contrast resolution made it possible to demonstrate neoplastic lesions of 4 mm in diameter. The lesion has low signal intensity on T1-weighted images and high signal intensity on T2-weighted. Parotid tumors cannot be characterized by signal intensity alone: only morphology allows to discriminate between benign and malignant lesions. To conclude, US is a screening method, while MRI is helpful in detecting multifocal lesions and in evaluating the tumor extent.
Extraskeletal Ewing's sarcoma (ES) and primitive neuroectodermal tumor (PNET) are widely regarded as clinically and histologically identical tumors which consist of small blue round cells. Extraskeletal ESs/PNETs usually occur in the deep soft tissues of the paraspinal region, chest wall, or lower extremities. However, superficially located cases, so-called cutaneous ESs/PNETs, are exceedingly rare, and the vast majority of the reported cases present as a single small mass. We present magnetic resonance imaging (MRI) findings and clinical course of a unique case of primary cutaneous ES/PNET presenting as numerous huge masses with severe ulceration on them. (orig.)
Although the majority of men presenting with non-seminomatous germ cell tumours (NSGCT) are cured, late relapse (occurring more than 2 years after obtaining a complete response to treatment) is increasingly recognized. The typical patterns of disease spread have been well-documented, but the findings at late relapse are more variable and less well-described. We discuss the phenomenon of late relapse, the characteristics of teratoma differentiated (TD), and the issue of long-term imaging surveillance of patients with NSGCT. The potential sites of late relapse of NSGCT and the associated spectrum of imaging appearances are illustrated.
Although the majority of men presenting with non-seminomatous germ cell tumours (NSGCT) are cured, late relapse (occurring more than 2 years after obtaining a complete response to treatment) is increasingly recognized. The typical patterns of disease spread have been well-documented, but the findings at late relapse are more variable and less well-described. We discuss the phenomenon of late relapse, the characteristics of teratoma differentiated (TD), and the issue of long-term imaging surveillance of patients with NSGCT. The potential sites of late relapse of NSGCT and the associated spectrum of imaging appearances are illustrated.
The long and resource intensive process of drug discovery and development is confronted with the basic challenge of providing effective and safe therapies at reasonably low costs. The better the mechanism of a disease is known, the higher the probability to find an appropriate therapy. Also, the better and earlier a disease can be diagnosed and characterized, the higher the chance to be able to interfere in this process with a chemical entity. This reasoning sets the framework for the use of imaging in drug discovery. We discuss the relevance of magnetic resonance imaging and spectroscopy to derive anatomical, functional, metabolic and target-related information in the context of pharmacological research in vivo. (author)
A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)
Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced ...
Brain CT images were reviewed of 98 schizophrenic patients and 90 healthy persons in relation to handedness and aging. CT images were further reconstructed to examine morphologically subtle changes in each region. Schizophrenic patients had progressive brain atrophy and dilated lateral ventricles, especially on the left side and in the posterior part of the lateral ventricle. These findings were more marked in left-handed than in right-handed schizophrenic patients. According to age groups, there were significant differences between schizophrenic and normal persons over the age of 40. The incidence of left handedness was significantly higher in schizophrenic patients in their fourties than the age-matched normal persons (31.4% vs 15.1%). Morphological abnormality and laterality might be due to the same pathologic consequences. (N.K.).
Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical sings, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure an complex organization. Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction.
What brain mechanisms underlie learning of new knowledge from single events? We studied encoding in long-term memory of a unique type of one-shot experience, induced perceptual insight. While undergoing an fMRI brain scan, participants viewed degraded images of real-world pictures where the underlying objects were hard to recognize ("camouflage"), followed by brief exposures to the original images ("solution"), which led to induced insight ("Aha!"). A week later, the participants' memory was tested; a solution image was classified as "remembered" if detailed perceptual knowledge was elicited from the camouflage image alone. During encoding, subsequently remembered images were associated with higher activity in midlevel visual cortex and medial frontal cortex, but most pronouncedly, in the amygdala, whose activity could be used to predict which solutions will remain in long-term ...
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image ...
The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weighted images (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted vascular involvement ...
Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and ...
The profusion of online digital images presents new challenges for image indexing. Images have always been problematic to describe and catalogue due to lack of inherent textual data and ambiguity of meaning. An alternative to time-consuming professionally-applied metadata has been sought in the form of tags, simple keywords that form a flat structure known as distributed classification, or more popularly as a folksonomy. This research aims to increase understanding of why people tag and how effective they find it for searching, using as the focus. Open-ended questionnaires were sent out to members of the photo-sharing website Flickr, with the opportunity to post comments to an online discussion space. There is also a systematic comparison between a tag-based system and a more traditional controlled vocabulary, to test out the claims made regarding the suitability of tagging for searching and browsing. ...
To compare the accuracy of MR imaging using an endorectal-pelvic and a pelvic phased-array coil for preoperative local staging of rectal carcinoma. To determine preoperative staging, 38 patients with rectal carcinoma underwent MR imaging. All patients were examined with both an endorectal-pelvic and a pelvic phased-array coil. All underwent surgery and staging was pathologically confirmed. Two radiologists blinded to pathologic stage analyzed perirectal invasion and perirectal node metastasis, and scored according to a four-point scale. Radiologic and pathologic findings were correlated. Receiver operating characteristic (ROC) analysis of Wilcoxon statistic (W values) was used to compare diagnostic accuracy between the two different MR methods. Interobserver variation was measured using {kappa} statistics. For perirectal invasion, T1WI endorectal-pelvic phased-array coil images (reader 1:0. 854, reader ...
Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.
We retrospectively studied the computed tomography scans of the orbit in 75 patients in order to identify the presence of incidental calcifications (scleral and trochlear apparatus calcifications.). These imagingfindings should integrate the vast list of differential diagnosis of orbital calcifications, as they may help radiologists to distinguish these calcifications from orbital foreign bodies. (author)
The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. ...
The purpose of this study was to compare a double freeze-thaw protocol to a triple freeze-thaw protocol for pulmonary cryoablation utilizing an in vivo porcine lung model. A total of 18 cryoablations were performed in normal porcine lung utilizing percutaneous technique with 9 each in a double- (10-5-10) and triple-freeze (3-3-7-7-5) protocol. Serial noncontrast CT images were obtained during the ablation. CT imagingfindings and pathology were reviewed. No imaging changes were identified during the initial freeze cycle with either protocol. However, during the first thaw cycle, a region of ground glass opacity developed around the probe with both protocols. Because the initial freeze was shorter with the triple freeze-thaw protocol, the imagingfindings were apparent sooner with this protocol (6 vs. 13 min). Also, despite a shorter total freeze time (15 vs. 20 ...
The hurried development of multimedia and internet allows for wide distribution of digital media data. It becomes much easier to edit, modify and duplicate digital information. In additional, digital document is also easy to copy and distribute, therefore it may face many threats. It became necessary to find an appropriate protection due to the significance, accuracy and sensitivity of the information. Furthermore, there is no formal method to be followed to discover a hidden data. In this paper, a new information hiding framework is presented.The proposed framework aim is implementation of framework computation between advance encryption standard (AES) and distortion technique (DT) which embeds information in image page within executable file (EXE file) to find a secure solution to cover file without change the size of cover file. The framework includes two main functions; first is the hiding of the information in the ...
The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imagingfindings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. ...
VSP data are usually acquired in order to obtain high-resolution images of complex structures in reservoirs and near boreholes. The authors present an elastic iterative migration scheme which has few limitations regarding the complexity of the geology, and where the macromodel for both P- and S-wave velocities is automatically improved and updated at each iteration. They avoid wavefield separation (up/down and P/S) and the simplifying assumptions of small dips underlying most such methods. The migration scheme is based on elastic inversion theory. The wavefield extrapolation is based on a high-order, coarse-grid, finite-difference solution to the elastic two-way wave equation. At each iteration, the macromodel is updated using a gradient method, in which the gradient is computed by correlation of forward-modelled fields with back-propagated residual fields. The first iteration of the migration scheme is equivalent to elastic reverse-time migration with an ...
The objective was to characterize imagingfindings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent ...
Six patients with eosinophilic granuloma were studied retrospectively in order to correlate the MRI appearances with the pathology. Ages ranged from 2 years 6 months to 11 years. The bones involved were the humerus, ulna, radius, femur, clavicle and ilium. Plain films, MRI and pathology specimens were obtained. A lytic lesion with indistinct margins, endosteal erosions and periosteal reaction was seen in all cases on plain radiographs. Bone marrow signal was decreased on T1-weighted images and increased on T2-weighted images throughout the bony lesion in all cases. T2-weighted images showed extensive soft-tissue abnormalities suggesting inflammatory changes in four cases. In two cases abnormalities were limited. Extensive changes correlated histologically with an early phase lesion. Localized minor changes were associated with a mid-phase lesion. Inflammatory soft-tissue changes could be associated with eosinophilic ...
The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). ...
Magnetic resonance imaging (MRI) was used to evaluate 22 histological proven peripheral nerve sheath tumors, approximately two-thirds of which arose in the lower extremity. The histologic distribution was as follows: 12 schwannomas, 7 neurofibromas, and 3 malignant peripheral nerve sheath tumors (2 of which occurred in patients with neurofibromatosis). Most lesions demonstrated an intermediate to moderately bright signal on T_1-weighted images and were minimally inhomogeneous. All lesions were moderately bright on T_2-weighted images, again with variable inhomogeneity. The extent of the tumor was best assessed on proton-density- and T_2-weighted images. Smooth margins were noted in 19 lesions. Of the 3 remaining lesions, 2 were malignant (but had been subjected to biopsy prior to MRI), and the other lesion was a plexiform neurofibroma. MRI accurately determined the relationship between the lesions and ...
Objective: To investigate the value ofMSCT in observing the direct findings of hilar cholangiocarcinoma1Methods Multislice helical CT studies were performed on the upper abdomen in 19 consecutive patientswith painless jaundice1 Precontrast and dynamic contrast enhanced (25 s phase and 60 s phase) scanswere conducted, and 3D imageswere reconstructed using enhanced raw data in 15 cases1 The direct CT findings of hilar cholangiocarcinoma were studied by three radiologists respectively in a 32scale strategy1 The morphological features and extension of bile duct involvement by hilar cholangiocarcinoma were analyzed1 All the 19 caseswere pathologically p roved as hilar cholangiocarcinoma by surgery (15 cases) and ERCP ( 4 cases) 1 Results The direct findings and extension of hilar cholangiocarcinoma could be demonstrated in 14 out of 15 3D reconstruction images, 8 out of 19 in 25 s phase, and 7 out of 19 in ...
This paper reports, to complement current knowledge on brain development, late regional brain maturation assessed with quantitative MR imaging. Axial and coronal head spin-echo (SE) images were obtained in 60 healthy individuals aged 5--56 years, with a double-echo, flow compensated imaging sequence obtained with a 1.5-T Magnetom spectroscopy and imaging system. T2-weighted images were calculated from the intensity differences in SE images at echo times (TEs) of 15 and 90 msec (TR = 2.5 second). The mean T2 values were determined at 16 sites in each cerebral hemisphere. T2 values of the six frontal subcortical white matter (FSCWM) sites and of the internal capsule (IC) were evaluated. Mean T2 values in the IC decreased until age 10 years, whereas this decrease continued in the FSCWM past age 15 years before reaching a plateau. Differential age-dependent patterns ...
Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, ...
Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images ...
Objective: To assess dynamic MRI with Gd-DTPA enhancement for evaluating inflammatory changes in the subacromial bursa. Design and patients: We detected the signal intensity changes in dynamic MRI of the subacromial bursa, and confirmed these macroscopically by arthroscopy and histologically. The signal intensity was measured using built-in software, and the enhancement ratio (E ratio) was calculated from dynamic MR images. In addition, as a parameter of the rate of the increase in the signal intensity from 0 to 80 s, the mean increase per second in the E ratio was obtained as the coefficient of enhancement (CE). The correlation was studied of the E ratio and CE with the arthroscopic findings (redness, villous formation, thickening and adhesion), and of the E ratio and CE with the histological findings (capillary proliferation, papillary hyperplasia, fibrosis and inflammatory cell infiltration) of the subacromial bursa. Of ...
Objective To investigate value of magnetic resonance cholangiopancreatography (MRCP) using oral diluted gadolinium (Gd)-diethylenetriamine penta-acetic acid (DTPA) as negative contrast materials in diagnosis of juxtapapillary duodenal diverticulum with atypical imaging features. Methods Nineteen patients with juxtapapillary duodenal diverticula of which imagingfindings were atypical underwent MRCP using oral diluted Gd-DTPA as negative contrast materials after conventional MRCP without any oral contrast materials. Results Twenty diverticula were revealed in the 19 patients. At conventional MRCP, the diverticula appeared as rounded lesion with high signal intensity. After oral administration of diluted Gd-DTPA, they disappeared at MRCP. These entities were diagnosed as duodenal diverticula...
Long before possible organic effects, exposure to ionizing radiations can provoke anxiety. In front of invisibility, the imagination quickly ignites. The terrorists have perfectly understood it. They are ready to use ionizing radiations as a weapon to remind traumatic images deeply rooted in people's memory. These images induce anxiety with all the clinical expressions connected to it. These symptoms require to be treated because of a possible anarchic development. For that purpose, plans have been elaborated to coordinate the different professional's actions. The coherence of medical management and communication aims to allow the most implicated people to find the way to face the events. When it is not possible, medico-psychological cells permit a specialized care. (author)
A new implementation of a shear-force microscope is described that uses a shear-force detection system to perform topographical imaging of large areas (#approx#1x1 mm"2). This implementation finds very interesting application in the study of archeological or artistic samples. Three dc motors are used to move a sample during a scan, allowing the probe tip to follow the surface and to face height differences of several tens of micrometers. This large-area topographical imaging mode exploits new subroutines that were added to the existing homemade software; these subroutines were created in Microsoft VISUAL BASIC 6.0 programming language. With this new feature our shear-force microscope can be used to study topographical details over large areas of archaeological samples in a nondestructive way. We show results detecting worn reliefs over a coin.
We present two cases of fetal neck masses that were initially diagnosed by ultrasound and further evaluated with prenatal MRI. MRI findings aided in further delineating the neck masses, increasing confidence in the final diagnosis (cervical teratoma and cystic hygroma). With the fetal airway typically filled with fluid that is of high signal on T2-weighted sequences, MRI images in three planes could identify whether the fetal larynx and trachea were partially or completely compressed by the neck tumor. This information was particularly useful in determining if a controlled delivery such as ex utero intrapartum treatment (EXIT) was necessary and aided the surgeons in planning their approach to establishing airway control in the delivery room. (orig.)
Purpose. We report a case of Ewing's sarcoma in the right distal femur in a 6-year-old male to demonstrate how dynamic contrast-enhanced magnetic resonance imaging (DEMRI) findings predicted histopathology. Materials and methods. DEMRI was performed at presentation and during and after completion of chemotherapy and radiation therapy. Histopathologic studies were done at presentation, at 77 weeks (20 weeks after a pathological fracture), and from the en bloc resection at 104 weeks. Results. DEMRI predicted the early tumor response, absence of tumor recurrence, presence of necrosis and lack of fracture healing, confirmed by histopathology. Conclusion. DEMRI is a clinically useful tool in managing Ewing's sarcoma. (orig.)
14 surgical patients with non-hepatobiliary diseases were studied with "9"9"mTc-EHIDA imaging to evaluate the effect of total parenteral nutrition (TPN) on the hepatobiliary function. Duration of TPN ranged from 6-56 days, 10 of the 14 patients Beijing within 10 days. The results showed that: (1) 11 of 14 patients had abnormal scintigraphic features. The most prominet findings were delayed liver excretion and prolonged blood clearance time. This fact suggests that not only the rate of excretion of the bile from the liver is decreased but the uptake ability of the hepatorcyte is also impaired. (2) The effect of TPN on liver function is reversible. It was concluded that in order to prevent irreversible damage of hepatobiliary function caused by TPN, the duration of TPN should not be too long and oral intake of nutrients should be resumed as soon as possible.
In 15 patients (16 hip joints) we found the clinical and radiological signs of BMOS. On T1-weighted MRI images areas of low signal intensity could be observed in the head, neck and the intertrochanteric region of the femur in various extensions. These areas showed a significant increase in signal intensity on the T2-weighted images. Because pain was resistant to conservative therapy all these patients were treated by core decompression of the femoral head in a prospective study. Bone cores were evaluated histologically using undecalcified sections and quantitative microradiography. The existence of intramedullary oedema in exactly the regions exhibiting the MRI pattern of bone marrow oedema was verified histologically; however, bone and marrow changes similar to those of early avascular necrosis (AVN) were also visible. (orig.)
The purpose of this study was to determine the feasibility of virtual endoscopy, named as ''virtual CT laparoscopy'', in the hepatobiliary system prior to laparoscopic cholecystectomy. We applied this technique to 28 patients suspected of having biliary disease. These images were compared and analyzed qualitatively based on visualization of the structures critical to operative cholangiography and surgical findings. Twenty-four patients, who underwent laparoscopic cholecystectomy, were evaluated as follows: the common bile duct and the hepatic duct were adequately visualized in 23 (96%) of the 24 patients, the cystic duct in 21 (88%), the gallbladder opacification in 20 (83%), the liver inferior surface in 20 (83%). Four patients had anatomic variations detected virtual CT laparoscopy and were proven by operative cholangiography and surgical findings. We emphasize that our new technique ...
The airborne traffic monitoring system forms a novel technology of detecting vehicle motion. An optical digital camera located on an airborne platform produces a series of images which then are processed to recognized the fixed vehicles. In this way the video data are converted into the time sequence of frames containing the vehicle coordinates. In the present work a three-frame algorithm is developed to identify the succeeding vehicle positions. It is based on finding the neighboring points in the frame sequence characterized by minimal acceleration. To verify and optimize the developed algorithm a ``Virtual Road'' simulator was created. Finally available empirical data are analyzed using the created algorithm.
This short article discusses the results of a market survey on ventilation systems for residential buildings and the role played by ventilation systems in our daily lives. Problems incurred as a result of insufficient ventilation conditions such as the formation of mould in dwellings whose windows have been replaced with better seals are discussed, for example. The negative image of air-conditioning and its causes are examined. The need for action in this area is stressed. Further findings of the study are presented, including a detailed review of current equipment and scenarios on how these systems can develop in the future. The extension of the study to cover the situation in further European countries is mentioned.
we report an ultrafast synchrotron x-ray phase contrast imaging study of the primary breakup mechanism of a coaxial air-assisted water jet. We demonstrate that there exist great similarities in the phenomenology of primary breakup with that of the secondary breakup. Especially, a membrane-mediated breakup mechanism dominates the breakup process for a wide range of air speeds. This finding reveals the intrinsic connections of these two breakup regimes and has deep implications on the unified theoretical approach in treating the breakup mechanism of high speed liquid jet.
Periureteral or subtrigonal injection of dextranomer/hyaluronic acid (Dx/HA) copolymer (Deflux, Q-Med, Uppsala, Sweden) is an increasingly common endoscopic treatment for vesicoureteral reflux. We report a confusing radiographic finding of bilateral calcified Dx/HA injections initially thought to represent bilateral distal ureteral stones in a boy who presented with intermittent periumbilical pain. Urologists, radiologists, and emergency room physicians should be aware of the potential for calcification of ureteral implants of Dx/HA, and of the potentially confusing radiographic images that may result. (orig.)
Problems and solutions in the diagnosis and operative treatment were clarified by retrospective evaluation of cases of intramedullary tumor in which MRI and surgery had been performed. The subjects were 16 patients (21-75 years old, mean age: 45 years) whose tumor was surgically removed between 1991 and 1998. MRI was performed preoperatively, and T1-weighted images, T2-weighted images, and enhanced images were obtained. Angiography was also performed in some cases. The histological diagnosis based on the MRI findings before surgery were compared with the pathological diagnosis after the operation. In 9/16 cases (56%), the preoperative histological diagnosis based on the MR images was the same as the pathological diagnosis after the operation. In 8 of the 11 cases (73%) whose images showed clear tumor margins and well shaped the tumor, the tumors were completely ...
Alexandria is the second largest urban governorate in Egypt and has seen significant urban growth in its modern and contemporary history. This study investigates the urban growth phenomenon in Alexandria, Egypt, using the integration of remote sensing and GIS. The urban physical expansion and change were detected using Landsat satellite images. The satellite images of years 1984 and 1993 were first geo referenced, achieving a very small RMSE that provided high accuracy data for satellite image analysis. Then, the images were classified using a tailored classification scheme with accuracy of 93.82% and 95.27% for 1984 and 1993 images respectively. This high accuracy enabled detecting land use/land cover changes with high confidence using a post-classification comparison method. One of the most important findings here is the loss of cultivated land in favour of ...
Human beings are confronted with another grievous disaster - coal fire. The monitoring on underground coal bed combustion relied on drilling supervising in the past, but this method is not good. By taking the coal fire of Gulaben mine in Inner Mongolia Autonomous Region as an example, the monitoring methods of underground coal bed combustion were explored based on the hyperspectra and high-resolution remote sensing technology. By employing the OMIS imaging apparatus developed by Shanghai Institute of Technical Physics of Chinese Academy of Sciences, the airborne hyperspectral images and the characteristic spectra of different types were obtained and the temperature was measured synchronously on the ground. Then according to the correlation of DN value of the thermal infrared band and surface temperature, the image information was processed, the spectral features were analyzed, and the surface temperature retrieval model was ...
Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the lesion(s). At the moment, several teams of neuroradiologists ...
This progress report covers period from Nov. 1, 1989 to Aug. 31, 1990. The long term objective was to develop receptor-binding radiotracers for SPECT or PET imaging of CNS or peripheral nervous system. The specific chemistry aims, as understood on the basis of past findings, were: to synthesize and develop a more polar analogs of 4IQNB, possessing similar binding characteristics but eliminated more rapidly from the surrounding tissues and the target organ, to design a method of introducing a technetium chelating group onto a molecule or cholinergic agent without drastic lowering of its apparent affinity, to synthesize and develop radiotracers based on m-AChR antagonists selective for one of the subtypes of the receptor. The chemistry service aims were to prepare and characterize (R,R)- and (R,S)-4IQNB and derivatives, to provide the triazene intermediate to other investigators, and to provide ({sup 123}I)4IQNB for in vivo ...
CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the inner ear and ...
The purpose of this study was to correlate MR imagingfindings with pathology in experimental hyperoxia-induced acute lung injury, which has similar pathology to diffuse alveolar damage (DAD). Seventeen Yorkshire pigs were studied. These animals were exposed to more than 80% oxygen for 24, 48, 72, and 96 hours in a sealed cage. The lungs were removed and inflated with air infused through the trachea, and then examined by both MRI and high-resolution CT (HRCT). T1-weighted spin-echo (T1WSE), T2-weighted fast (T2WFSE), and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences were performed. Severity in MR findings and signal-to-noise ratios (SNR) on MR images were well correlated with pathological scores. CT values were also correlated well with pathologic scores. Abnormal SNR values were obtained from a pathological score of 5, whereas abnormal CT values were obtained from a ...
The ability to use an acoustic stethoscope to detect lung and/or heart sounds, and then to then communicate one's interpretation of those sounds is an essential skill for many medical professionals. Interpretation of lung and heart sounds, in the context of history and other examination findings, often aids the differential diagnosis. Bedside assessment of changing auscultation findings may also guide treatment. Learning lung and heart auscultation skills typically involves listening to pre-recorded normal and adventitious sounds, often followed by laboratory instruction to guide stethoscope placement, and finally correlating the sounds with the associated pathophysiology and pathology. Recently, medical simulation has become an important tool for teaching prior to clinical practice, and for evaluating bedside auscultation skills. When simulating cardiovascular or pulmonary problems, high-quality lung and heart sounds should be able to ...
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)
This study was performed to evaluate the diagnostic usefulness of double-phase Tc-99m MIBI parathyroid scintigraphy with single photon emission computed tomography (SPECT) in patients with hyperparathyroidism. We also evaluated the relationship between Tc-99m MIBI uptake and oxyphil cell contents in parathyroid glands. The subjects were 28 parathyroid glands of 10 patients who underwent Tc-99m MIBI parathyroid scintigraphy and parathyroidectomy for clinically suspected hyperparathyroidism. Early and delayed pinhole images were obtained at 15 minutes and 2 hours after injection of Tc-99m MIBI, and SPECT images were followed. The weight and oxyphil cell contents of parathyroid tissue were obtained from pathologic specimen, and the scintigraphic findings were compared with histopathology. In surgical histopathology, 6 parathyroid adenomas and 9 parathyroid hyperplasias were confirmed. The sensitivity, specificity, and positive ...
To assess the CT findings of intrahepatic cholangiocarcinoma associated with hepatolithiasis. The CT features of 26 patients with cholangiocarcinoma and hepatolithiasis were reviewed and compared with those of 23 patients with intrahepatic stones alone, acting as control subjects. CT findings were analyzed for tumor appearance and adjacency to hepatolithiasis. We studied clinical findings, noting the presence or absence of wall thickening or soft tissue attenuation within the bile duct, the luminal diameter of dilated bile duct, and the presence of periductal enhancement, and compared these with the findings for control groups. CT images of the tumor revealed a hepatic low-attenuating mass with peripheral rim enhancement(n = 14,54 %), or periductal thickening, or low-attenuating lesions in segmental dilatation of intrahepataic bile ducts(n = 12, 46 %). Most hepatic tumors were seen ...
Schizophrenia and bipolar disorder share genetic risk, brain vulnerability, and clinical symptoms. The ZNF804A risk variant, rs1344706, confers susceptibility for both disorders. This study aimed to identify neural mechanisms common to both schizophrenia and bipolar disorder through this variant's potential effects on cortical thickness, white matter tract integrity, and cognitive function. Imaging, genetics, and cognitive measures were ascertained in 62 healthy adults aged between 18 and 59 years. High-resolution multimodal MRI/DTI imaging was used to measure cortical thickness and major frontotemporal and interhemispheric white matter tracts. The general linear model was used to examine the influence of the ZNF804A rs1344706 risk variant on cortical thickness, white matter tract integrity, and cognitive measures. Individuals homozygous for the risk variant ('A' allele) demonstrated reduced cortical gray matter thickness in the superior ...
To elucidate the dynamic features of CT scans in peripheral cholangiocarcinoma for the differentiation of this tumor from various primary hepatic neoplasms. Materials were 24 cases of pathologically confirmed peripheral cholangiocarcinoma. Contrast enhancement patterns of central and peripheral portion of the masses were analyzed at three phases including arterial dominant(22), tissue equilibria(24), and postequilibria(9). Other associated CT findings and laboratory data were analyzed. Serum total bilirubin was mostly below 2 mg/dl(22/24), hepatitis B surface antigen was positive in only 9%, serum alphafetoprotein was elevated in 18%, carcinoembryonic antigen in 47%, cancer antigen 19-9 in 60%. In the arterial dominant image(22), 50% of the cases showed peripheral hyperdensity and 50% total hypodensity. In the tissue equilibrial images(24), 63% showed total hypodensity, 25% peripheral hyperdensity, and 13% total isodensity. ...
We present an image of the rupture propagation of the 2004 M6.0 Parkfield earthquake using records from a dense network of local strong motion stations. We back-propagate high-frequency waveforms in 3D with a method, similar to reverse time migration, to obtain an estimate of the distribution of radiated high-frequency seismic energy in space and time. The image is forced to be coherent at the known hypocenter location and the quake origin time by applying small static time shifts obtained using waveform cross-correlation. We observe that the Parkfield earthquake radiated a distinct secondary high-frequency phase, which is located about 12.5~km northwest of the hypocenter with an onset of seismic radiation about 5~s after the rupture initiation. The time history of the back-projection suggests a rupture velocity of 2.5~km/s between hypocenter and subevent. The back-projection result is confirmed by inversion of picked arrival times of the ...
Aim: To evaluate magnetic resonance cholangiography (MRC) with high-resolution dynamic gadolinium-enhanced magnetic resonance imaging (MRI) in determining the imaging features of hilar cholangiocarcinoma that relate to tumour extent and influence resectability. Materials and methods: Twenty-six patients that underwent resection were reviewed. Tumour location and extent, lobar atrophy, the degree of portal vein and hepatic artery involvement were recorded. The findings were correlated with surgical and histopathological findings. Results: Biliary assessment was concordant in 14 and discordant in eight of 14 stented and four of 12 non-stented patients. In 63/82 veins and 43/74 arteries results were fully concordant. The mean sensitivity, specificity, positive and negative predictive values (PPV, NPV) in predicting involvement of the main portal vein (MPV) at surgery were 83.3, 100, 100, and 92.5%; of the ...
... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...
We present the first 3.8 {micro}m image of the dusty ring surrounding the young binary system GG Tau, obtained with the W. M. Keck II 10m telescope's adaptive optics system. THis is the longest wavelength at which the ring has been detected in scattered light so far, allowing a multi-wavelength analysis of the scattering proiperties of the dust grains present in this protoplanetary disk in combination with previous, shorter wavelengths, HST images. We find that the scattering phase function of the dust grains in the disk is only weakly dependent on the wavelength. This is inconsistent with dust models inferred from observations of the interstellar medium or dense molecular clouds. In particular, the strongly forward-throwing scattering phase function observed at 3.8 {micro}m implies a significant increase in the population of large ({approx}> 1 {micro}m) grains, which provides direct evidence for grain ...
This paper presents new images and spectroscopy of NGC 34 (Mrk 938) obtained with the du Pont 2.5-m and Baade 6.5-m telescopes at Las Campanas, plus photometry of an HST archival V image. This Mv = -21.6 galaxy has often been classified as a Seyfert 2, yet recently published infrared spectra suggest a dominant central starburst. We find that the galaxy features a single nucleus, a main spheroid containing a blue central disk, and tidal tails indicative of two former disk galaxies. These galaxies appear to have completed merging. The remnant shows three clear optical signs that the merger was gas-rich ("wet") and accompanied by a starburst: (1) It sports a rich system of young star clusters, of which 87 have absolute magnitudes -10.0 > Mv > -15.4. Five clusters with available spectra have ages in the range 0.1-1.0 Gyr, photometric masses between 2x10^6 and 2x10^7 Msun, and are gravitationally bound young globulars. (2) ...
Sonography, subtraction scintigraphy, computed tomography and MRI were compared in 100 patients who had surgery 105 times for hyperparathyroidism (HPT). Surgical and pathological data were available for all operations. A total of 105 MR, 77 CT, 84 sonograms and 70 subtraction scintigrams were performed. The ability of the imaging modalities, individually and in combination, to detect HPT, histology, size, concomitant thyroid disease and location of the diseased glands has been evaluated. For primary HPT, sensitivity ranged from 68% for MRI to 40% for scintigraphy but was much lower for tertiary HPT with all modalities. The ability to identify diseased glands was strongly size dependent for all methods. If patients had had previous neck surgery, the most sensitive methods were MRI and scintigraphy and this also held true for patients with concomitant thyroid disease and ectopically located glands. The findings presented suggest that while ...
The diagnosis of dialysis-related amyloid (AB-amyloid) has been based usually on clinical and radiological criteria. Following the discovery that beta 2-microglobulin was the major protein of this amyloid, we isolated and radiolabelled uremic plasma beta 2-microglobulin. After intravenous injection, gamma-camera images of selected joint areas were obtained from 42 patients who were on regular hemodialysis therapy. Positive scans involving the shoulder, hip, knee and carpal regions were found in 13 of 14 patients treated for more than 10 years and 10 of 16 patients treated for 5 to 10 years. Patients treated for less time had negative scans. Specificity was indicated by negative scans in non-amyloid inflammatory lesions in control hemodialysis patients. Up to 48-fold tracer enrichment was detected in excised AB-amyloid containing tissue as compared to amyloid-free tissue. These findings suggest that circulating radiolabelled beta 2-microglobulin ...
Fourteen surgical patients with non-hepatobiliary diseases were studied with "9"9Tc"m EHIDA imaging to evaluate the effect of total parenteral nutrition (TPN) on the hepatobiliary function. The duration of TPN ranged from 6 to 56 days; for 10 of the 14 patients it was between 6 to 10 days. The results showed that: (1) 11 of 14 patients had abnormal scintigraphic features. The most prominent findings were delayed liver excretion and prolonged blood clearance time. This fact suggests that not only the rate of excretion of the bile from the liver is decreased but the uptake ability of the hepatocyte is also impaired. (2) The effect of TPN on liver function is reversible. The authors conclude that in order to prevent irreversible damage of hepatobiliary function caused by TPN, the duration of TPN should not be too long and oral intake of nutrients should be resumed as soon as possible. (author). 9 refs, 3 figs, 3 tabs.
The diagnostic imagingfindings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and Computed Tomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.
The vertical profiles of disc galaxies are built by the material trapped around stable periodic orbits, which form their "skeletons". According to this, the knowledge of the stability of the main families of periodic orbits in appropriate 3D models, can predict possible morphologies for edge-on disc galaxies. In a pilot survey we compare the orbital structures which lead to the appearance of "peanuts" and "X"-like features with the edge-on profiles of three disc galaxies (IC 2531, NGC 4013 and UGC 2048). The subtraction from the images of a model representing the axisymmetric component of the galaxies reveals the contribution of the non-axisymmetric terms. We find a direct correspondence between the orbital profiles of 3D bars in models and the observed main morphological features of the residuals. We also apply a simple unsharp masking technique in order to study the sharpest features of the images. Our basic conclusion is ...
Secondary ischemic necrosis of femoral head due to loss of blood supply following to femoral neck fracture is well known. The regional distribution of bone-seeking radiopharmaceuricals in the skeleton can depend on a number of factors, but bone blood flow is a major physiological determinant of regional skeletal uptake of Tc-99m polyphosphate and bone imaging may thus be used for the evaluation of vascularity of the femoral head. The authors made a comparative study of scintigraphic findings and operative findings of 28 cases of femoral neck fracture treated at Kyung Hee University Hospital from April 1980 to May 1984. The results were as follows: 1. In 16 cases of proven avascular necorsis of femoral head, scintigraphy showed absent or decreased activity in 14 cases (87.5%), while radiography showed increased density in 10 cases (62.5%). 2. In 12 cases of proven vital femoral head, scintigraphy showed increased activity in ...
Subjects were 18 cases with adenocarcinoma of 20 mm or less in diameter, which were detected and resected surgically from September, 1993 to August, 1998. On these cases, thin-Section CT (TSCT) images were compared with pathological findings. Patients were 15 men and 3 women, with mean age of 63.4-year-old. An average tumor size was 11.5 mm (5-17 mm). According to pathological classification of Noguchi, type A as in 6 cases, type B in 3, type C in 7 and type F in 2. TSCT was carried by vas voltage =150 kVp, vas current =200 mA, beam width =2 mm, WW =2000 HU, and WL =-700 HU. The ratio of CT attenuation value in cancer by TSCT correlated with the ratio of aeration rate in the pathologic specimen. The cases of 30% or less on the ratio of CT attenuation value were 100% in types A and B, and 71% in type C. These results suggested that it is necessary to devide into two type in group of type C and the ratio of CT attenuation value is important on ...
To assess the malignant potential of small({<=}15mm) portal defects seen on CT arterial portography, the findings of CT hepatic arteriography and lipiodol CT were reviewed. In 91 patients who underwent both CTAP and CTHA, small portal defects were reviewed for frequency, multiplicity and location. We prospectively evauluated changes in the size and enhancement pattern of malignant lesions on follow up CT according to density on CTHA, location, lipiodol deposits on lipiodol CT, and multiplicity. Among the 91 patients, 102 small defects were defected in 42 patients(46%). Small portal defects were benign, malignant, and of undetermined malignant potential in 77%, 20% and 3% of cases, respectively. Small portal defects that were hyperattenuated on CTHA, and lipiodol deposits on lipiodol CT, were malignant in 42% and 70% of cases, respectively. Location and multiplicity did not show statistically significant variation between benign and malignant defects. Small ...
Recent wide-field imaging observations of the X-ray luminous cluster RDCSJ1252.9-2927 at z=1.24 uncovered several galaxy groups that appear to be embedded in filamentary structure extending from the cluster core. We make a spectroscopic study of the galaxies in these groups using GMOS on Gemini-South and FORS2 on VLT with the aim of determining if these galaxies are physically associated to the cluster. We find that three groups contain galaxies at the cluster redshift and that they are probably bound to the cluster. This is the first confirmation of filamentary structure as traced by galaxy groups at z>1. We then use several spectral features in the FORS2 spectra to determine the star formation histories of group galaxies. We find a population of relatively red star-forming galaxies in the groups that are absent from the cluster core. While similarly red star forming galaxies can also be found in the field, the average ...
We investigate monoenergetic gamma-ray signatures of Z^1 dark matter annihilations in a non-minimal Universal Extra Dimensions model. The self-interactions of the non-Abelian Z^1 gauge boson give rise to a large number of contributing Feynman diagrams that do not exist for annihilations of the Abelian gauge boson B^1, which is the standard Kaluza-Klein dark matter candidate. We find that the annihilation rate is indeed considerably larger for the Z^1 than for the B^1. Even though relic density calculations indicate that the mass of the Z^1 should be larger than the mass of the B^1, the predicted fluxes are of the same order of magnitude. We compare our results to existing experimental limits, as well as to future sensitivities, for image air Cherenkov telescopes, and we find that the limits are reached already with a moderately large boost factor. However, the realistic prospects for detection depend on the energy ...
Using the Sloan Digital Sky Survey (SDSS) and the FIRST (Faint Images of the Radio Sky at Twenty Centimeters) catalogs, we examined the optical environments around double-lobed radio sources. Previous studies have shown that multi-component radio sources exhibiting some degree of bending between components are likely to be found in galaxy clusters. Often this radio emission is associated with a cD-type galaxy at the center of a cluster. We cross-correlated the SDSS with the FIRST catalog and measured the richness of the cluster environments surrounding both bent and straight multi-component sources. This led to the discovery and classification of a large number of galaxy clusters out to a redshift of z ~ 0.5. We divided our sample into smaller subgroups based on their optical and radio properties. We find that FR I radio sources are more likely to be found in galaxy clusters than FR II sources. Further, we find that bent ...
Authors obtained T1-weighted MRI images of the femoral head after fracture of the femoral neck and classified the signals into four patterns to investigate the sequential changes of the femoral head. The T1-weighted MRI images obtained initially after femoral neck fracture showed a normal pattern in 10 of the 15 hip joints studied. MRI images obtained subsequently still showed the normal signal pattern in eight of the 10 hip joints which had shown the normal pattern in the first MRI, while two of the 10 joints subsequently showed a band pattern. The joint with the homogeneous pattern in the first MRI subsequently showed a band pattern. Of the three joints with an inhomogeneous pattern in the first MRI, two joints showed a subsequent band pattern, and the other a normal pattern. The joints which showed a band pattern continued to show a similar band pattern. Eventually, all hip joints studied showed a normal or band pattern ...
Background: Malformations of cortical development vary in neuronal maturity and level of functioning. Purpose: To characterize regional relative cerebral blood volume (rCBV) and difference in first moment transit time (TTfm) in polymicrogyria and cortical tubers using magnetic resonance (MR) perfusion imaging. Material and Methods: MR imaging and dynamic T2*-weighted MR perfusion imaging were performed in 13 patients with tuberous sclerosis complex, 10 with polymicrogyria, and 18 controls with developmental delay but no macroscopic brain abnormality. Regions of interest were placed in cortical tubers or polymicrogyric cortex and in the contralateral normal-appearing side in patients with malformations. In 'control' subjects, regions of interest were placed in the frontal and parietal lobes in both hemispheres. The rCBV and TTfm of the tuber/contralateral side (rCBVRTSC and TTFMTSC) as well as those of the ...
A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated each wire into its own ...
This paper reports the findings of a study that explores the perspectives of 25 young Cypriots regarding the symbolic values of smoking with respect to their everyday lived experiences. This study was motivated by recognising the high levels of smoking prevalence among adolescents in Cyprus and the absence of published research 'recording' their own versions of reality about smoking. Data for the study were generated from one-to-one qualitative interviews which encouraged the participants to articulate the symbolic value of smoking in their day-to-day experiences. The analysis focuses first, on the content of the embedded symbolic values of smoking (e.g. the quality of being 'cool') and second on the role of these values (e.g. used in projecting an image) in their everyday lives. A central...
A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T_1- and T_2-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG).
Purpose - This paper aims to discuss the procedures and methods developed at Washington State University to digitize and make accessible historic moving images. Design/methodology/approach - The paper describes the selection and the use of low-cost technologies to transfer analog film to digital formats. Issues related to the conversion, description, and online hosting of digital films are also addressed. Findings - Though the steps involved in digitizing film are not trivial, the benefits of access both for the public and archives staff outweigh the expense and labor involved. The procedures described in this paper involve low upfront costs and are sustained through cost recovery fees. Research limitations/implications - The focus of this paper is on managing, describing, and providing on...
Dusty primordial disks surrounding young low-mass stars are revealing tracers of stellar and planetary formation. The evolution and lifetime of these disks define the boundary conditions of the mechanisms of planet formation. Stellar companions, however, can significantly change this evolution through their tidal interactions. Stellar evolution and planet formation in binaries have to respond to an environment of truncated, quickly disappearing disks--very different compared to an isolated star environment. In order to investigate details of the influence of binarity on circumstellar disk evolution, we obtained adaptive optics supported near-infrared imaging and spectroscopy of the individual components of 22 low-mass binaries in the well-known Orion Nebula Cluster. Brackett gamma emission, which we detect in several systems, is used as a tracer for the presence of an active accretion disk around each binary component. We find a low fraction of ...
Summary. Ratiometric fluorescent dyes are often used to monitor free ion concentrations in vivo, especially in cells that are recalcitrant to transformation with genetically encoded fluorescent markers. Although intracellular dye distributions are often found to be cytosolic, dye localisation has often not been examined in detail. We began exploring the use of BCECF (2?,7?-bis(2-carboxyethyl)-5(6)-carboxyfluorescein) to monitor pH in the giant alga Chara australis and discovered that younger leaf cells could be loaded using the acetoxymethyl ester of BCECF. However, we were puzzled to find in microphotometric measurements that the fluorescence ratio appeared insensitive to manipulations affecting cytosolic pH. Confocal imaging of C. australis cells loaded with BCECF showed an accumulation ...
Abstract Results of numerous experiments conducted over the past 15-years by using behavioural as well as brain imaging methods have shown that musical expertise influences brain anatomy, brain functions and behaviour. The musician- brain is thus considered as a very good model of brain plasticity. Moreover, many results have demonstrated that musical expertise not only impacts on music processing but also on several aspects of speech processing including lexical pitch, sentence intonation and the metric structure of words. Conversely, recent results indicated that linguistic expertise with tone or quantity languages such as Mandarin Chinese, Thai, Finnish and Japanese, influences the processing of harmonic tones and musical intervals. We discuss possible interpretations of these findings ...
Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)
There are no specific diagnostic tests or a gold standard method for measuring disease activity and outcome in spondyloarthropathies (SpA). Many different methods have been developed to assess the signs and symptoms in SpA. The aim of this study was to evaluate the value of scintigraphy, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and Bath Ankilosing Spondylitis Disease Activity Index (BASDAI) in the evaluation of disease activity in early axial SpA diagnosed with magnetic resonance imaging (MRI). Thirty early MRI-positive axial SpA patients (23 males, 7 females) with a median age of 35 (18?55) years and a median duration of inflammatory low back pain of 24 (8?60) months were included in the study. In the patients with sacroiliitis, the sensitivity, specificity, and pos...
We investigate the extent to which the pure magnification effect of gravitational lensing can be extracted from galaxy clustering statistics, by a nulling method which aims to eliminate terms arising from the intrinsic clustering of galaxies. The aim is to leave statistics which are free from the uncertainties of galaxy bias. We find that nulling can be done effectively, leaving data which are relatively insensitive to uncertainties in galaxy bias and its evolution, leading to cosmological parameter estimation which is effectively unbiased. This advantage comes at the expense of increased statistical errors, which are in some cases large, but it offers a robust alternative analysis method to cosmic shear for cosmological imaging surveys designed for weak lensing studies, or to full modelling of the clustering signal including magnification effects.
A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.
The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imagingfindings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. ...
Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available
AIM: To assess the impact of the introduction of a computed tomography (CT) imaging protocol for multi-trauma patients on the workload, overall diagnostic yield, and effect on detection of cervical spine injury and pneumothorax. METHOD: Between February 1997 and April 2004, all patients presenting acutely to the Emergency Department (ED) with haemodynamically stable trauma (Abbreviated Injury Scale 3 or more) involving more than two body systems were imaged with a comprehensive pre-set helical CT protocol (including non-contrast head, cervical spine: cranio-cervical and cervico-thoracic junctions; and oral and intravenous contrast-enhanced thoracic, abdomen and pelvis) after initial triage and a standard trauma series of radiographs (chest, lateral C-spine and pelvis). Diagnosis of cervical spine fracture and pneumothorax was noted before and after the CT protocol was carried out and findings from all studies were recorded ...
The objective of this study was to determine the usefulness of parathyroid scintigraphy in histological estimation for secondary hyperparathyroidism (2HPT) using Tc-99m sestamibi or Tc-99m tetrofosmin. Tc-99m sestamibi (MIBI) and Tc-99m tetrofosmin (Tetro) parathyroid imaging following double-phase study, magnetic resonance imaging (MRI), and ultrasound were performed on 14 patients with 2HPT. All patients underwent parathyroidectomy. The uptake of two tracers in parathyroid areas was compared with the histopathologic findings. Forty-nine parathyroid glands were surgically explored and histologically proven to be hyperplastic. Of these, 42 were diagnosed with nodular type (N-type) hyperplasia, and 7 with diffuse type (D-type) hyperplasia. MIBI and Tetro parathyroid imagings detected 34 and 35 parathyroid glands, respectively. The sensitivity of MIBI was determined to be 76.2% (32/42) for N-type, and ...
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T{sub 2}-weighted turbo-spin-echo (TSE) and T{sub 1}-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm{sup 2}. Lymph nodes with a diameter of {>=}8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes ({>=} 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR ...
As part of an ongoing strategic research project to find barrels of radioactive waste off San Francisco, the U.S. Navy (USN), the U.S. Geological Survey (USGS), and the Gulf of the Farallones National Marine Sanctuary (GFNMS) pooled their expertise, resources, and technology to form a partnership to verify new computer enhancement techniques developed for detecting targets the size of 55 gallon barrels on sidescan sonar images. Between 1946 and 1970, approximately 47,800 large barrels and other containers of radioactive waste were dumped in the ocean west of San Francisco; the containers litter an area of the sea floor of at least 1400 km {sup 2} knows as the Farallon Island Radioactive Waste Dump. The exact location of the containers and the potential hazard the containers pose to the environment is unknown. The USGS developed computer techniques and contracted with private industry to enhance sidescan data, collected in cooperation with the ...
Our aim was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for preoperative assessment of local tumoral spread in hilar cholangiocarcinoma. Thirteen of 30 consecutive patients with hilar cholangiocarcinoma who underwent surgery, excluding 17 patients who underwent biliary drainage or preoperative portal embolization, were retrospectively evaluated. Using MDCT systems of 4 detector rows or 16 detector rows, plain and dynamic contrast-enhanced images of three phases were obtained. Extent of tumor spread and lymph node metastasis were assessed with MDCT and compared with histopathological findings. The Bismuth-Corlette classification of hilar cholangiocarcinoma with MDCT were type I, 1 patient; type IIIa, 3 patients; type IIIb, 4 patients; and type IV, 5 patients; those with histopathological findings were type I, 1 patient; type IIIa, 2 patients; type IIIb, 4 patients; and type IV, 6 ...
Objective: Solid pseudopapillary tumor of the pancreas (SPTP tumor) is a rare pancreatic neoplasm with low malignant potential, which usually affects female patients in the second or third decades of life. It is a non-functional, slow-growing neoplasm that very often reaches considerable size before the first symptoms appear. Symptomatology is frequently related to tumor size. Surgical excision is usually curative in most cases. Infrequently the tumor can appear in male patients or in aged women, which can make the diagnosis more difficult. Some patients develop liver metastases in the follow-up that can be resected. Our purpose is to review the radiological and pathological findings of SPTP with emphasis on these infrequent cases. Subjects and methods: The medical records and radiological findings of patients who underwent surgery for SPTP between 2000 and 2005 were retrospectively reviewed. Study eligibility required that patients had ...
Objective: Solid pseudopapillary tumor of the pancreas (SPTP tumor) is a rare pancreatic neoplasm with low malignant potential, which usually affects female patients in the second or third decades of life. It is a non-functional, slow-growing neoplasm that very often reaches considerable size before the first symptoms appear. Symptomatology is frequently related to tumor size. Surgical excision is usually curative in most cases. Infrequently the tumor can appear in male patients or in aged women, which can make the diagnosis more difficult. Some patients develop liver metastases in the follow-up that can be resected. Our purpose is to review the radiological and pathological findings of SPTP with emphasis on these infrequent cases. Subjects and methods: The medical records and radiological findings of patients who underwent surgery for SPTP between 2000 and 2005 were retrospectively reviewed. Study eligibility required that patients had ...
Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical signs, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure and complex organization). Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction. [Italian] L'infarto intestinale rappresenta una malattia rara e tipica del soggeto ...
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...
This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)
We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available
In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available
This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available
Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications
Detailed three dimensional wing kinematics and aerodynamic characteristics are experimentally presented for the free flight of a beetle, Allomyrina dichotoma, which has a pair of elytra (fore wings) and hind wings. The kinematic parameters of the wing motion, such as the wing tip trajectory, angle of attack, torsion angle, and camber deformation, are obtained from a 3D reconstruction technique that involves the use of two or three synchronized high-speed cameras to digitize various points marked on the wings. Our data show outstanding characteristics of wing deformation and flexibility in the free flight of the beetle. To find out the mechanism of aerodynamic force, the leading edge vortex (LEV) and trailing edge vortex (TEV) on both elytron and hind wing were observed by using smoke wire visualization and digital particle image velocimetry (DPIV) technique. Qualitative smoke lines in the region of the most intent vortex shedding demonstrate ...
(abridged) We present a study of stellar population of LAEs at z=4.86 in GOODS-N and its flanking field. With the publicly available IRAC data in GOODS-N and further IRAC observations in the flanking fields, we select five LAEs which are not contaminated by neighboring objects in IRAC images and construct their observed SEDs with I_c, z', IRAC 3.6micron, and 4.5micron band photometry. The SEDs cover the rest-frame UV to optical wavelengths. We derive stellar masses, ages, color excesses, and star formation rates of five LAEs using SED fitting method. Assuming the constant star formation history, we find that the stellar masses range from 10^8 to $10^{10} Msun with the median value of 2.5x10^9 Msun. The derived ages range from very young ages (7.4 Myr) to 437 Myr with a median age of 25 Myr. The color excess E(B-V) are between 0.1-0.4 mag. Star formation rates are 55-209 Msun/yr. A comparison of the stellar populations is made between three LAEs ...
Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find only a very narrow range of destruction around the holes in contrast to the ...
The investigation of interfaces between thin organic films and metal surfaces is a field of highest interest because it represents the basis for future applications of organic electronic devices. In this context, phtalocyanines are of particular interest since repulsive intermolecular interaction was found recently for this group of organic molecules. Tin(II)-phtalocyanine (SnPc) is non-planar and can adsorb in two different geometries: with the Sn atom pointing downwards (Sn down) or upwards (Sn up). In our group different Pc molecules have previously been studied using several experimental techniques like SPA-LEED or XSW. Here we present STM studies of SnPc on Ag(111), taken at different coverages and temperatures, and discuss the results in the context of our previous findings. At low coverages the formation of chains can be observed for Sn down molecules while Sn up molecules tend to stay separated. This originates from a strong interaction with the substrate ...
The nuclear pore complexes (NPCs) reversibly disassemble and reassemble during mitosis. Disassembly of the NPC is accompanied by phosphorylation of many nucleoporins although the function of this is not clear. It was previously shown that in the transmembrane nucleoporin gp210 a single serine residue at position 1880 is specifically phosphorylated during mitosis. Using amino acid substitution combined with live cell imaging, time-lapse microscopy and FRAP, we investigated the role of serine 1880 in binding of gp210 to the NPC in vivo. An alanine substitution mutant (S1880A) was significantly more dynamic at the NPC compared to the wild-type protein, suggesting that serine 1880 is important for binding of gp210 to the NPC. Moreover a glutamate substitution (S1880E) closely mimicking phosphorylated serine specifically interfered with incorporation of gp210 into the NPC and compromised its post-mitotic recruitment to the nuclear envelope of daughter nuclei. Our ...
Focused ion beam (FIB) milling techniques are presented aiming at the manipulation of both tin dioxide (SnO_2) inverted opals and polystyrene (PS) direct opals. Different SnO_2 opals are considered in order to estimate the regularity of their bulk after the production. A SnO_2 mesoporous monolith is FIB micromachined to make it suitable for optical applications. PS direct opals are structured by FIB milling at different scales. Ordered arrays of PS opals are modified by selectively removing a single sphere. In performing this task, we discuss the effects on the FIB milling due to the gas-assisted enhanced etching and to the binding of the nearest neighbours. Techniques to achieve imaging of PS opals in absence of a conductive coating are also brought up. Furthermore, isolated PS spheres are drilled with or without enhanced etching in order to produce controlled defects on them. The FIB-assisted manipulations we show may find potential ...
60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A brilliant MR-tomographic imaging of the small bowel is possible under the condition, that the small bowel contrast is optimal. The ...
35 patients with ankle sprain were examined by MRI and stress radiographs. 13 were operated afterwards, 22 patients underwent a functional conservative therapy and were examined by MRI and stress radiographs and second time after three months. MRI reports were correct in 12 of 13 operated cases. After conservative therapy we did not find any disrupted ankle ligament. MRI showed intact ligaments thickened by scar. (orig./MG) [Deutsch] 35 Patienten mit klinischem Verdacht auf Aussenbandruptur wurden mit der MRT untersucht. 13 Patienten wurden operiert, 22 konzervativ therapiert. Letztere wurden nach drei Monaten erneut mit MRT und gehaltenen Aufnahmen untersucht. Die MRT-Befunde stimmten in 12 von 13 Faellen mit den operativ erhobenen Befunden ueberein. Nach dreimonatiger konzervativer Therapie waren alle 22 Sprunggelenke stabil. Die rupturierten Baender stellten sich verdickt und durchgaengig dar. (orig./MG)
MR studies of 6 patients with intracranial tuberculoma are reviewed. All patients also underwent CT scans which showed hypo- or isodense lesions with abnormal enhancement following contrast administration. MR showed lesions with prolongation of the T1 relaxation time in every case. On the T2-weighted sequences, the signal properties of the tuberculoma varied according to the stage of evolution of the lesion. Incipient tuberculomas appeared as scattered areas of hypointensity surrounded by edema. Mature tuberculomas were composed of a dark necrotic center surrounded by an isointense capsule which was, in turn, surrounded by edema. In one patient, the center of the lesion was hyperintense probably because of liquefaction and pus formation (tuberculous abscess). While both, CT and MR, were equally sensitive in visualizing the intracranial tuberculoma in every patient, MR was slightly superior in demonstrating the extent of the lesion, especially for brainstem tuberculomas. Nevertheless, ...
We present results from Spitzer Space Telescope observations of the mid-infrared phase variations of three short-period extrasolar planetary systems: HD 209458, HD 179949 and 51 Peg. We gathered IRAC images in multiple wavebands at eight phases of each planet's orbit. We find the uncertainty in relative photometry from one epoch to the next to be significantly larger than the photon counting error at 3.6 micron and 4.5 micron. We are able to place 2-sigma upper limits of only 2% on the phase variations at these wavelengths. At 8 micron the epoch-to-epoch systematic uncertainty is comparable to the photon counting noise and we detect a phase function for HD 179949 which is in phase with the planet's orbit and with a relative peak-to-trough amplitude of 0.00141(33). Assuming that HD 179949b has a radius R_J < R_p < 1.2R_J and a small Bond albedo, it must recirculate less than 30% of incident stellar energy to its night side at the 1-sigma ...
Uterus didelphys with obstructed hemivagina and ipsilateral renal agenesis is a rare entity, sometimes referred to as Herlyn-Werner-Wunderlich syndrome (HWW). It usually presents after menarche with progressive pelvic pain, sometimes with regular menses, and a palpable mass due to hemihaematocolpos. The diagnosis is generally made only if the suspicion of this genitourinary syndrome is raised. To highlight the imaging diagnostic clues in this rare condition. We report on 11 adolescents with this condition. Sonography mostly allowed the correct diagnosis by showing uterovaginal duplication, haematocolpos or haematometrocolpos, and the absence of the ipsilateral kidney. MRI provided more detailed information regarding uterine morphology, the continuity with each vaginal channel (obstructed and nonobstructed), and the bloody nature of the contents. Early and accurate diagnosis of this syndrome is important so that adequate and prompt surgical therapy (excision of the ...
Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using X-ray CT. This idea ...
One of the most interesting discoveries of the X-ray Telescope and EUV Imaging Spectrometer (EIS) on board the Hinode solar observatory is the presence of persistent high temperature high speed outflows from the edges of active regions. Measurements by EIS indicate that the outflows reach velocities of 50 km/s with spectral line asymmetries approaching 200 km/s. It has been suggested that these outflows may lie on open field lines that connect to the heliosphere, and that they could potentially be a significant source of the slow speed solar wind. A direct link has been difficult to establish, however. In this letter, we use EIS measurements of spectral line intensities that are sensitive to changes in the relative abundance of Si and S as a result of the first ionization potential (FIP) effect, to measure the chemical composition in the outflow regions of AR 10978 over a period of 5 days in December 2007. We find that Si is always enhanced ...
The purpose of this study was to assess the efficacy of MRM in providing preoperative locoregional information on patients with breast cancer. MRI was performed on 62 female breast cancer patients. A 1.5 T MR-system was used to acquire fat-suppressed T{sub 1}WI, T{sub 2}WI and dynamic-contrast-enhanced images with an SPGR pulse sequence. The extent of the cancer measured with MRM was confirmed histologically in all patients. The size obtained from MRM correlated well with the size obtained histologically, including intraductal spread of cancer (R: 0.853). As for shape, the round/oval type evident from MRM correlated more accurately (R: 0.934) than the ill-defined type associated with a linear and/or clumped enhanced area (R:0.744). The difference between the size obtained from MRM and the size obtained histologically, including IDS, was less than 15 mm in the majority of patients (93.5%). MRM accurately reveals the extent of cancer, including IDS, and is effective ...
Tantalum and tantalum-based thin films have gained precedence as the diffusion barrier for copper interconnects used in the latest generation of integrated circuits (ICs). The paper presents insight and observations on the covariance of texture and grain size of wrought tantalum sputtering targets and their influence on sputtering performance. Previous studies involving deposition trials of tantalum targets of varying metallurgical character had demonstrated that both grain size and textural homogeneity is critical for assuring reliable sputtering performance of tantalum. Subsequently, a model had been proposed to prescribe how localized texture bands and orientation clusters in tantalum are effectively resistant to sputter erosion. In this paper, results of atomic force microscopy (AFM) and orientation imaging microscopy (OIM{sup TM}) analyses on the eroded surface of a tantalum sputtering target are presented. Initial findings support the ...
Through analysis of archival images and photometry from the Spitzer GLIMPSE and MIPSGAL surveys combined with Two Micron All Sky Survey and MSX data, we have identified 488 candidate young stellar objects (YSOs) in the giant molecular cloud M17 SWex, which extends #approx#50 pc southwest from the prominent Galactic H II region M17. Our sample includes >200 YSOs with masses >3 M _s_u_n that will become B-type stars on the main sequence. Extrapolating over the stellar initial mass function (IMF), we find that M17 SWex contains >1.3 x 10"4 young stars, representing a proto-OB association. The YSO mass function is significantly steeper than the Salpeter IMF, and early O stars are conspicuously absent from M17 SWex. Assuming M17 SWex will form an OB association with a Salpeter IMF, these results reveal the combined effects of (1) more rapid circumstellar disk evolution in more massive YSOs and (2) delayed onset of massive star formation.
By both increasing the optical iris of the video camera and removing the grid in fluoroscopic procedures involved in placement of a Dubbhoff feeding tube, the radiation dose to patients and staff was reduced by five to seven times. An average expected dose to a patient of about 300 mGy per procedure was reduced by two to three times when the grid was removed and by an additional three times when an iris of increased diameter was used. Because Dobbhoff procedures do not involve obtaining a diagnosis, the image degradation was acceptable and did not affect the total exposure times or ability to conduct the procedure. With the grid out, the difference between the mean exposure times of 5.1 minutes in 96 patient studies done with a normal iris opening and 4.0 minutes in 52 studies done with an enlarged iris was not statistically significant. The importance of reducing patient dose is reinforced by the finding that one-third of the patients ...
Regulation of transcription initiation by RNA polymerase II requires TFIID, a multisubunit complex composed of the TATA binding protein (TBP) and at least seven tightly associated factors (TAFs). Some TAFs act as direct targets or coactivators for promoter-specific activators while others serve as interfaces for TAF-TAF interactions. Here, we report the molecular cloning, expression and characterization of Drosophila dTAFII60 and its human homolog, hTAFII70. Recombinant TAFII60/70 binds weakly to TBP and tightly to the largest subunit of TFIID, TAFII250. In the presence of TAFII60/70, TBP and TAFII250, a stable ternary complex is formed. Both the human and Drosophila proteins directly interact with another TFIID subunit, dTAFII40. Our findings reveal that Drosophila TAFII60 and human TAFII70 share a high degree of structural similarity and that their interactions with other subunits of TFIID are conserved.Images
Hot-torsion testing was used to establish the cavitation behavior of a typical alpha/beta titanium alloy, Ti-6Al-4V, with a colony microstructure, during simple-shear deformation. For this purpose, sections of deformed specimens were examined by optical metallography, and by scanning and orientation-imaging microscopy (OIM). It was found that cavity nucleation occurred along prior beta boundaries as well as at triple points; in particular, most cavities nucleated along boundaries perpendicular to the axial direction of the specimen. Extensive growth was observed for cavities surrounded by both hard and soft orientations, with the soft colonies accommodating more of the imposed strain. At high degrees of deformation, dynamic globularization of the colony microstructure adjacent to the cavities was also observed. In addition, the metallographic observations revealed that the cavities did not grow in an equiaxed mode, but in an elliptical manner. A tensor describing ...
The spectral properties of Lyman break galaxies (LBGs) offer a means to isolate pure samples displaying either dominant Ly-alpha in absorption or Ly-alpha in emission using broadband information alone. We present criteria developed using a large z ~ 3 LBG spectroscopic sample from the literature that enables large numbers of each spectral type to be gathered in photometric data, providing good statistics for multiple applications. In addition, we find that the truncated faint, blue-end tail of z ~ 3 LBG population overlaps and leads directly into an expected Ly-alpha emitter (LAE) population. As a result, we present simple criteria to cleanly select large numbers of z ~ 3 LAEs in deep broadband surveys. We present the spectroscopic results of 32 r' <~ 25.5 LBGs and r' <~ 27.0 LAEs at z ~ 3 pre-selected in the Canada-France-Hawaii Telescope Legacy Survey that confirm these criteria.
A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g ...
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.
A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.
Attention Deficit Hyperactivity Disorder (ADHD) is a neurobiological disorder of early childhood onset. Defining symptoms are chronic impairments of attention, impulse control and motor hyperactivity that frequently persist until adulthood. Miscellaneous causes of the disorder have been discussed. Accumulating evidence from imaging- and molecular genetic studies strengthened the theory of ADHS being a predominantly inherited disorder of neurobiological origin. In the last 15 years, non-invasive brain imaging methods were successfully implemented in pediatric research. Functional magnetic resonance imaging studies gave major insight into the neurobiological correlates of executive malfunction, inhibitory deficits and psychomotoric soft signs. These findings are in good accordance with brain morphometric data indicating a significant volumetric decrease of major components of striato-thalamo-cortical ...
Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager (`Vision`, Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and ...
Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ring-shaped uptake ...
To evaluate injury patterns of facet joints and associated soft tissue injuries in patients with acute traumatic cervical facet joint injuries. From among patients with cervical spine trauma, 27 with facet joint injuries, as seen on CT and MRI, were chosen for this study. CT scans were analyzed with regard to the location of facet joint injury, the presence or absence of facet dislocation or fracture, and other associated fractures. MR images were analyzed with regard to ligament injury, intervertebral disc injury, intervertebral disc herniation, and spinal cord injury. The most common location of facet joint injury was C6-7 level(n=10), followed by C5-6(n=8). Among these 27 patients with facet joint injuries, 12(44%) had bilateral injuries and 15(56%) unilateral injuries. Facet fractures were present in 17 cases(63%) and the fracture of inferior facet was more frequent than superior. Patterns of fracture were vertical, transverse, or comminuted, but vertical ...
In rare cases, large adrenal masses with a suspicion of malignancy exhibit tumor extension into the adrenal vein and inferior vena cava. When planning surgery, the relationship of the extension to the inferior vena cava is of decisive improtance. We describe in two cases on the detection of a tumor thrombus in the inferior vena cava arising from a malignant adrenal mass by means of MR angiography (TOF, coronary 2D GRE images [FLASH], 3 slices acquired during 15 second apnea). The angiograms correlated well with the results of DSA venacavography and with the intraoperative findings. Thus, MRA has been demonstrated to be suitable for the certain proof of a venous tumor thrombus not only in cases of renal cell carcinomas but also in cases of malignant adrenal masses. The method should be applied whenever there is evidence of a venous involvement in the adrenal MR images. (orig.) [Deutsch] Grosse malignomverdaechtige ...
Full text: Disorders of brain development and phakomatosis are resulting from disturbed embryonic-foetal development One third of all major embryological anomalies involve CNS, and over 2000 different anomalies have been described. Anomalies of the brain often cause foetal and neonatal death, and mental and physical retardation in pediatric group. The majority of disorders of brain development and phakomatosis are idiopathic, and most of them are not hereditary or familial. Ultrasonography plays the important role in screening foetal and neonatal brain, but after closure of fontanels it is difficult to find the acoustic window. CT has limited contrast resolution, and disadvantage exposing infant to ionizing radiation. It is helpful to demonstrate the presence of calcifications. MR imaging has proved to be a diagnostic tool of major importance in children with disorders of brain development and phakomatosis. The excellent grey/white matter ...
Numerical simulations show that box-shaped bulges of edge-on galaxies are not bulges: they are bars seen side-on. Therefore, the two components that are seen in edge-on Sb galaxies such as NGC 4565 are a disk and a bar. But face-on SBb galaxies always show a disk, a bar, and a (pseudo)bulge. Where is the (pseudo)bulge in NGC 4565? We use archival Hubble Space Telescope H-band images and Spitzer Space Telescope 3.6 #mu#m wavelength images, both calibrated to Two Micron All Sky Survey K_s band, to penetrate the prominent dust lane in NGC 4565. We find a high surface brightness, central stellar component that is clearly distinct from the boxy bar and from the disk. Its brightness profile is a Sersic function with index n = 1.55 #+-# 0.07 along the major axis and 1.33 #+-# 0.12 along the minor axis. Therefore, it is a pseudobulge. It is much less luminous than the boxy bar, so the true pseudobulge-to-total luminosity ratio of ...
Sixty-three subjects, aged 6 months to 16 years, who were enrolled in a prospective, fully blinded, randomized parallel-group phase III clinical trial, received 0.1 mmol/kg doses of either Gd-BOPTA (n=29) or Gd-DTPA (n=34). The MR images were acquired before and within 10 min of contrast agent injection. The primary objective was to compare the difference from pre-dose to post-dose lesion visualization between Gd-BOPTA and Gd-DTPA. Lesion visualization was determined as the sum of individual scores for three criteria of lesion morphological characteristics (lesion border delineation, internal morphology, and contrast enhancement), each assessed qualitatively using 4-point scales. Quantitative evaluation compared changes in lesion-to-background (LBR) and contrast-to-noise (CNR) ratios and per cent enhancement. Monitoring for adverse events and evaluation of vital signs and laboratory values was performed. Pre-dose to post-dose changes in lesion visualization were ...
A central problem in diagnostic radiology is to compare a new X-ray picture with a previous picture and from this comparison be able to decide if anatomical changes have occurred in the patient or not. It is of primary interest that these pictures are identical in projection. If not it is difficult to decide with confidence if differences between the pictures are due to anatomical changes or differences in their projection geometry. In this thesis we present a non invasive method that makes it possible to find the relative changes in the projection geometry between the exposure of a previous picture and a new picture. The method presented is based on the projection slice theorem (central section theorem). Instead of an elaborate search for a single new picture a pre-planned set of pictures are exposed from a circular orbit above the patient. By using 3D Fourier transform techniques we are able to synthesize a new X-ray picture from this set of pictures that is ...
In a prospective study 102 patients with malignant tumors of the tongue, oropharynx, hypopharynx, and larynx were staged by means of MRI. Special attention was directed at those tumour extensions that could influence the treatment strategy. The MR findings were correlated with the results of palpation, endoscopy, ultrasound, computerised tomography and histopathological findings. MRI showed a good delineation of pT{sub 2} to pT{sub 4} tumours. However, visualisation of small tumours in the soft palate, the tonsils, the pyriform sinuses and vocal cords was difficult. In conclusion our results suggest that in addition to endoscopy MRI is a valuable tool for the examination of tumours of tongue, oropharynx, hypopharynx and larynx. (orig.) [Deutsch] In einer prospektiven Studie wurden 102 Patienten mit malignen Tumoren der Mundhoehle, des Oro- und Hypopharynx sowie des Larynx mit der Mgnetresonanztomographie (MRT) untersucht, wobei besonders Wert ...
Clinical information is indispensable for swift and cost-effective clarification of diseases of the larynx. While quality clarification of neurological changes in the area of the posterior cranial fossa and in the course of the vagus nerve as a cause of glottis malfunction is possible with MRI, localized disease of the larynx can more effectively be assessed with low-artifact CT. In the particularly difficult assessment of the post-operative larynx, a recurrence can be diagnosed only after a baseline study has been carried out after the end of therapy. With knowledge of the pretherapeutic findings, the findings immediately post-therapy, and the operation technique used, the optimal CT examination, which can be carried out quickly, will be able to provide more information about recurrence. (orig.) [Deutsch] Zur schnellen und kostenguenstigen Abklaerung von Erkrankungen des Larynx ist die klinische Information unabdingbar: Wenn neurologische ...
To analyze the enhancement patterns and morphology of peripheral cholangiocar-cinomas (CCs), as seen on three-phase helical CT. Three-phase helical CT scans of 25 cases of 24 patients with pathologically-proven CCs were retrospectively reviewed. After intravenous administration of contrast media, scans of the hepatic arterial phase (HAP) were obtained at 30 seconds, of the portal venous phase (PVP) at 70 seconds, and of the delayed phase (DP) at 3 minutes. Linear, dense, marginal enhancement was seen in 17 CCs (68%), mainly on HAP images (64%) while thick, band-like, peripheral enhancement was seen in 18 (72%), on either PVP (52%) or DP (44%). Internal enhancement was observed in 23 CCs (92%) on PVP (68%) and/or DP (88%), and 19 CCs (76%) among them showed incomplete enhancement of stippled and/or septated patterns. Most (76%) were seen throughout all three phases to be hypoattenuating, as compared to the surrounding parenchyma. On HAP, wedge-shaped parenchymal ...
Aim of this retrospective study was to assess the capability of contrast-enhanced helical computerised tomography (CT) in sigmoid diverticulitis, especially relative to selection of the appropriate treatment. The findings of 41 patients were reviewed from 1998 to 1999 June. Contrast-enhanced helical CT is the imaging modality of choice in assessing mild or severe acute diverticulitis because it provides useful information for appropriate treatment planning in the emergency setting. This technique is most useful in questionable cases and in patients with suspected severe diverticulitis where a choice must be made between different treatment options. [Italian] Scopo di questo studio retrospettivo e' illustrare i molteplici aspetti radiologici della flogosi diverticolare sigmoidea con tomografia computerizzata (TC) spirale, con specifico riguardo alle implicazioni terapeutiche che scaturiscono dall'analisi e dal confronto dei ...
Involvement of the dopaminergic system has been suggested in patients suffering from attention deficit hyperactivity disorder (ADHD) since the symptoms can be successfully treated with methylphenidate, a potent blocker of the dopamine transporter (DAT). This study reports the findings on the status of the DAT in adults with ADHD before and after commencement of treatment with methylphenidate, as measured using [{sup 99m}Tc]TRODAT-1. Seventeen patients (seven males, ten females, aged 21-64 years, mean 38 years) were examined before and after the initiation of methylphenidate treatment (3 x 5 mg/day). All subjects were injected with 800 MBq [{sup 99m}Tc]TRODAT-1 and imaged 3 h p.i. Single-photon emission tomography (SPET) scans were acquired using a triple-headed gamma camera. For semi-quantitative evaluation of the DAT, transverse slices corrected for attenuation were used to calculate specific binding in the striatum, with the cerebellum used ...
We investigate the relationship between spiral arms and star formation in the grand-design spirals NGC 5194 and NGC 628 and in the flocculent spiral NGC 6946. Filtered maps of near-IR (3.6 #mu#m) emission allow us to identify 'arm regions' that should correspond to regions of stellar mass density enhancements. The two grand-design spirals show a clear two-armed structure, while NGC 6946 is more complex. We examine these arm and interarm regions, looking at maps that trace recent star formation-far-ultraviolet (GALEX NGS) and 24 #mu#m emission (Spitzer SINGS)-and cold gas-CO (HERACLES) and H I (THINGS). We find the star formation tracers and CO more concentrated in the spiral arms than the stellar 3.6 #mu#m flux. If we define the spiral arms as the 25% highest pixels in the filtered 3.6 #mu#m images, we find that the majority (60%) of star formation tracers occur in the interarm regions; this result persists qualitatively ...
Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with a specific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CT images were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was unilateral in 41% of cases and most frequently involved the right lower lobe. Bilateral ...
Research into methods for reasoning under uncertainty is currently one of the most exciting areas of artificial intelligence, largely because it has recently become possible to record, store, and process large amounts of data. While impressive achievements have been made in pattern classification problems such as handwritten character recognition, face detection, speaker identification, and prediction of gene function, it is even more exciting that researchers are on the verge of introducing systems that can perform large-scale combinatorial analyses of data, decomposing the data into interacting components. For example, computational methods for automatic scene analysis are now emerging in the computer vision community. These methods decompose an input image into its constituent objects, lighting conditions, motion patterns, etc. Two of the main challenges are finding effective representations and models in specific applications and ...
To determine the demographics, imagingfindings, clinical symptoms, and prognosis of primary vertebral Ewing's sarcoma (PVES). A retrospective review of medical records and radiological studies of patients diagnosed with PVES from 1936 through 2001 in our institution and Department of Pathology consultation files was undertaken. Metastatic and soft tissue Ewing's sarcoma cases were excluded. From a total of 1,277 cases of Ewing's sarcoma, 125 (9.8%) had a primary vertebral origin. There were 48 females and 76 males. Patient ages ranged from 4 to 54 (mean 19.3, standard deviation 10.7, median 16) years. Vertebral column distribution was four cervical (3.2%), 13 thoracic (10.5%), 31 lumbar (25%), and 67 sacrum (53.2%). More than one vertebral segment was involved in ten cases (8%). Satisfactory imaging studies were available in 51 patients: 49 radiographs, 27 computerized tomography (CT), and 23 magnetic resonance ...
The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...
For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema ...
Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...
The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available
PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available
This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available
A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.
Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available
Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available
Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available
Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available
This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.
The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available
Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available
Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...
An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed T{sub 1}-weighted spin echo sequences before ...
Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)
A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.
An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.
This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.
Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available
Low temperature Nonphotochemical Hole Burning (NPHB) Spectroscopy of the dye rhodamine 800 (MF680) was applied for the purpose of discerning differences between cultured normal and carcinoma ovarian surface epithelial (OSE) cells. Both the cell lines were developed and characterized at the Mayo Clinic (Rochester, MN), with the normal cell line having been transfected with a strain of temperature sensitive Simian Virus 40 Large T Antigen (SV40) for the purpose of extending the life of the cell culture without inducing permanent changes in the characteristics of the cell line. The cationic lipophilic fluorophore rhodamine 800 preferentially locates in in situ mitochondria due to the high lipid composition of mitochondria and the generation of a large negative membrane potential (relative to the cellular cytoplasm) for oxidative phosphorylation. Results presented for NPHB of MF680 located in the cells show significant differences between the two cell lines. The results are interpreted on ...
Low temperature Nonphotochemical Hole Burning (NPHB) Spectroscopy of the dye rhodamine 800 (MF680) was applied for the purpose of discerning differences between cultured normal and carcinoma ovarian surface epithelial (OSE) cells. Both the cell lines were developed and characterized at the Mayo Clinic (Rochester, MN), with the normal cell line having been transfected with a strain of temperature sensitive Simian Virus 40 Large T Antigen (SV40) for the purpose of extending the life of the cell culture without inducing permanent changes in the characteristics of the cell line. The cationic lipophilic fluorophore rhodamine 800 preferentially locates in in situ mitochondria due to the high lipid composition of mitochondria and the generation of a large negative membrane potential (relative to the cellular cytoplasm) for oxidative phosphorylation. Results presented for NPHB of MF680 located in the cells show significant differences between the two cell lines. The results are interpreted on ...
The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the ...
The transversus perinei profundus muscle is a well known structure in found anatomical textbook. Fibres of this muscle are believed to form the so-called external urethral sphincter (musculus sphincter urethrae). Recently histomorphologic investigations have shown that there is no muscular connection between the musculus sphincter urethrae (external sphincter) and the muscle system of the pelvic floor. Furthermore, the external sphincter was found to be divided into parts: The transversely striated part (musculus sphincter urethrae transversostriatus) and the smooth part (musculus sphincter urethrae glaber). Similar to histomorphologic investigations, contrast-enhanced MR imaging has shown the musculus sphincter urethrae to be surrounded by fatty and connective tissue only. Neither in MRI nor in anatomical slices can any connection between the urethral sphincter and the muscle system of the pelvic floor be found. Thus, on the basis of the results presented in this ...
The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at ...
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...
Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and ...
Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...
The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided ...
CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the inner ear and ...
This document - IAEA Safeguards: Implementation Blueprint of Commercial Satellite Imagery - constitutes the second report from SSC Satellitbild giving a structured view and solid guidelines on how to proceed with a conceivable implementation of satellite imagery to support Safeguards activities of the Agency. This Phase 2 report presents a large number of concrete recommendations regarding suggested management issues, work organisation, imagery purchasing and team building. The study has also resulted in several lists of actions and preliminary project plans with GANT schedules concerning training, hardware and software, as well as for the initial pilot studies. In both the Phase 1 and Phase 2 studies it is confirmed that the proposed concept of a relatively small Imagery Unit using high-resolution data will be a sound and feasible undertaking. Such a unit capable of performing advanced image processing as a tool for various safeguard tasks will give the Agency an ...
We investigate theoretically subwavelength imaging by acoustic metamaterial slabs immersed in the liquid matrix. A near-field subwavelength image formed by evanescent waves is achieved by a designed metamaterial slab with negative mass density and positive modulus. A subwavelength real image is achieved by a designed metamaterial slab with simultaneously negative mass density and modulus. These results are expected to shed some lights on designing novel devices of acoustic metamaterials.
X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging
Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.
The computer vision approach to image analysis is discussed from two aspects. First, this approach is constrasted to the pattern recognition approach. Second, how external knowledge and information and models from other fields of science and engineering can be used for image and scene analysis is discussed. In particular, the connections between computer vision and computer graphics are pointed out.
The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.
Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.
This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.
On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of the two ...
In this study we tried to develop the long-range transport system and find the way to prevent from the radiological emergency risk. For the study, meteorological forecast system in Korea Meteorological Administration is investigated. Numerical simulation is also carried out by the long-range transport model and Vis-5D. We surveyed the emergency preparedness for nuclear accidents which were ARAC in USA, RODOS in Europe and WSPEED in Japan and then investigated the processing of medium- and long-range atmospheric diffusion modeling system. We also studied on the application of KMA/NWPD model which are GDAPS and RDAPS. In the future, it is necessary to produce to the high resolution meteorological data from KMA/NWPD for the development of medium- and long-range atmospheric diffusion modeling system and construct the integrated system for data processing in real time. It was simulated by using micro-scale meteorological field applying wind field model with high ...
To study the three-dimensional (3D) magnetic field topology and its long-term evolution associated with the X3.4 flare of 2006 December 13, we investigate the coronal relative magnetic helicity in the flaring active region (AR) NOAA 10930 during the time period of December 8-14. The coronal helicity is calculated based on the 3D nonlinear force-free magnetic fields reconstructed by the weighted optimization method of Wiegelmann, and is compared with the amount of helicity injected through the photospheric surface of the AR. The helicity injection is determined from the magnetic helicity flux density proposed by Pariat et al. using Solar and Heliospheric Observatory/Michelson Doppler Imager magnetograms. The major findings of this study are the following. (1) The time profile of the coronal helicity shows a good correlation with that of the helicity accumulation by injection through the surface. (2) The coronal helicity of the AR is estimated to ...
The particulate matter of a light-duty diesel engine was characterized in its morphology, sizes, internal microstructures, and fractal geometry. A thermophoretic sampling system was employed to collect particulates directly from the exhaust manifold of a 1.7-liter turbocharged common-rail direct-injection diesel engine. The particulate samples collected at various engine-operating conditions were then analyzed by using a high-resolution transmission electron microscope (TEM) and an image processing/data acquisition system. Results showed that mean primary particle diameters (dp), and radii of gyration (Rg), ranged from 19.4 nm to 32.5 nm and 77.4 nm to 134.1 nm, respectively, through the entire engine-operating conditions of 675 rpm (idling) to 4000 rpm and 0% to 100% loads. It was also revealed that the other important parameters sensitive to the particulate formation, such as exhaust-gas recirculation (EGR) rate, equivalence ratio, and temperature, affected ...
Pancreatic amyloid deposits of amylin are a hallmark of Type II diabetes and considerable evidence indicates that amylin oligomers are cytotoxic to beta-cells. Many efforts are presently spent to find out naturally occurring molecules, or to design synthetic ones, able to hinder amylin aggregation or to protect cells against aggregate cytotoxicity. In this context, a protective effect of some polyphenols against amyloid cytotoxicity was reported. Actually dietary polyphenols are endowed with multiple health benefits, and extra virgin olive oil is attracting increasing interest as a source of these substances. Here, we investigated the effects on amylin aggregation and cytotoxicity of the secoiridoid oleuropein aglycon, the main phenolic component of extra virgin olive oil. We found that oleuropein, when present during the aggregation of amylin, consistently prevented its cytotoxicity to RIN-5F pancreatic beta-cells, as determined by the ...
This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses ...
Ratiometric fluorescent dyes are often used to monitor free ion concentrations in vivo, especially in cells that are recalcitrant to transformation with genetically encoded fluorescent markers. Although intracellular dye distributions are often found to be cytosolic, dye localisation has often not been examined in detail. We began exploring the use of BCECF (2',7'-bis(2-carboxyethyl)-5(6)-carboxyfluorescein) to monitor pH in the giant alga Chara australis and discovered that younger leaf cells could be loaded using the acetoxymethyl ester of BCECF. However, we were puzzled to find in microphotometric measurements that the fluorescence ratio appeared insensitive to manipulations affecting cytosolic pH. Confocal imaging of C. australis cells loaded with BCECF showed an accumulation of the dye in two locations: (1) on the outside of the chloroplasts in irregularly shaped stationary bodies; (2) within 1-1.5 mum structures that moved rapidly with ...
Previous studies have documented dissimilatory growth of bacteria on solid Mn{sup 4+} oxide, but Mn{sup 3+} oxides have not been previously studied; here the authors have demonstrated for the first time the bacterial reduction of manganite. Strain MR-4 of Shewanella putrefaciens was able to grow on and rapidly reduce insoluble needle-shaped crystals of synthetic manganite (MnOOH), converting them to soluble Mn{sup 2+} in the process. The rate of Mn{sup 3+} reduction was optimal at pH of 7.0 and 26 C consistent with an enzymatic reaction. In addition the rates of reduction were in proportion to the amount of manganite added, but nearly independent of the cell concentration present (e.g., cell number had only a small effect on the rate of Mn{sup 3+} reduction at early stages of growth) suggesting that surface properties were dictating the rates of metal reduction. This thesis was supported by major differences in reduction rates when Mn oxides of different surface areas were studied. ...
The aim of this work was to develop several strategies and software-packages for the evaluation of in-vivo-data of the human brain, which were acquired with high-resolution 1H-MRSI at 1.5 and 3 T. Several studies involving phantoms, volunteers and patients were performed. Quality assurance studies were conducted in order to evaluate the reproducibility of the applied MR-techniques at both field strengths. A qualitative comparison-study between MRSI-data from a 1.5 T clinical MR-scanner and a 3 T research MR-scanner showed the advantages of the more advanced MRSI sequences and higher field strength (3 T). A study involving patients with primary brain tumours (gliomas) was performed in cooperation with the Department of Neurosurgery (University of Erlangen-Nuremberg). The methods developed in the course of this study, such as the integration of MRS-data into a stereotactic-system, the segmentation of metabolic maps and the correlation with histopathological findings ...
We derive stellar masses, ages, and star formation histories (SFHs) of massive early-type galaxies in the z = 1.237 RDCS1252.9-2927 cluster and compare them with those measured in a similarly mass-selected sample of field contemporaries drawn from the Great Observatories Origin Deep Survey South Field. Robust estimates of these parameters are obtained by comparing a large grid of composite stellar population models with 8-9 band photometry in the rest-frame near-ultraviolet, optical, and IR, thus sampling the entire relevant domain of emission of the different stellar populations. Additionally, we present new, deep U-band photometry of both fields, giving access to the critical far-ultraviolet rest frame, in order to empirically constrain the dependence of the most recent star formation processes on the environment. We also analyze the morphological properties of both samples to examine the dependence of their scaling relations on their mass and environment. We ...
Based on their interesting properties, metal nanoparticles show the potential as an analytical tool in electronic (Burmeister et al. 2004), optical (Yguerabide and Yguerabide 1998), and catalytic applications (Liu 2006). Their characteristics depend on the composition, shape, and size of the single particles. These various properties are utilized in many different approaches such as optics, magnetics (Lang et al. 2007), and laser technology (Csaki et al. 2007). We investigated an alternative method for the synthesis of nanoparticles. In this case, an enzyme, horseradish peroxidase, induces a silver deposition and replaces a metal nanoparticle as the reaction seed. Depending on the reaction time, we could obtain particles in a range of few nanometers up to more than 250 nm. For a better understanding of the enzymatic silver deposition process, the silver particles produced by this process were analyzed by SEM, TEM, and atomic force microscopy (AFM) on a single particle level after ...
The low in vivo transduction efficiency of recombinant adeno-associated virus (rAAV) and the undesirably strong immunogenicity of adenovirus (rAdv) have limited their clinical utilization in cancer gene therapy. We have previously demonstrated that intratumoral injection of rAAV expressing a C-terminal polypeptide of human telomerase reverse transcriptase (rAAV-hTERTC27) effectively inhibits the growth of glioblastoma xenografts in nude mice. To further improve its efficacy, we combined rAAV-hTERTC27 with rAdv and investigated the efficiency of the cocktail vectors in vivo. At a nontherapeutic dose (1 x 10(8) plaque-forming units (PFUs)), rAdv-null and rAdv-hTERTC27 were equipotent in enhancing the therapeutic efficacy of rAAV-hTERTC27 (1.5 x 10(11) v.g.), and complete tumor regression was achieved in 25% of the treated animals. Importantly, the combination of rAAV-hTERTC27 and a therapeutic dose (2.5 x 10(9) PFU) of rAdv-hTERTC27 significantly augmented the therapeutic effects and led ...
Differentiated thyroid cancer (DTC) has variable degree of F-18 FDG avidity. The purpose of this study was to evaluate the relationship between F-18 FDG uptake and pathological or immunohistochemical features of DTC. DTC patients who underwent both pre-operative F-18 FDG PET/CT scan and surgery were included in the study. Maximum standardized uptake values (SUVmax) of primary tumor were calculated. If the primary tumor showed no perceptibly increased F-18 FDG uptake, region of interest was drawn based on finding of CT portion of the PET/CT images. Pathological and immunohistochemical markers such as presence of lymph node (LN) metastasis and underlying thyroiditis, tumor size, Ki-67 labeling index, expressions of EGFR, COX-2, and Galectin-3 were evaluated. Total of 106 patients was included (102 papillary carcinomas, 4 follicular carcinomas). The mean SUVmax of the large tumors (above 1 cm) was significantly higher than the mean SUVmax of small ...
The methodology of achieving a high power density (HPD, or brake mean effective pressure) direct-injection Diesel engine has been studied, which is directed to using high fuel/air ratio, high-speed and ceramic engine components. Among the main thrust to achieve these engine changes for an advanced Diesel engine is the design of a high injection pressure (HIP) fuel system. During the course of the present study, two Cummins 903 engines mated with a Rutger-built HIP were employed to investigate the engine response to HIP and in-cylinder processes by using the Rutgers high-speed infrared (IR) spectral digital imaging system. Five separate technical publications were prepared to report results obtained from the study. The main findings include: The HIP system permits engine operation at an air/fuel ratio of as rich as 18 to 1 with smoke emission not worse than with the conventional mechanical (low pressure) injection system; A high injection ...
We report five new measurements of central black hole masses based on Space Telescope Imaging Spectrograph and Wide Field Planetary Camera 2 observations with the Hubble Space Telescope (HST) and on axisymmetric, three-integral, Schwarzschild orbit-library kinematic models. We selected a sample of galaxies within a narrow range in velocity dispersion that cover a range of galaxy parameters (including Hubble type and core/power-law surface density profile) where we expected to be able to resolve the galaxy's sphere of influence based on the predicted value of the black hole mass from the M-#sigma# relation. We find masses for the following galaxies: NGC 3585, M _B_H = 3.4"+"1"."5 _-_0_._6 x 10"8 M _s_u_n; NGC 3607, M _B_H = 1.2"+"0"."4 _-_0_._4 x 10"8 M _s_u_n; NGC 4026, M _B_H = 2.1"+"0"."7 _-_0_._4 x 10"8 M _s_u_n; and NGC 5576, M _B_H = 1.8"+"0"."3 _-_0_._4 x 10"8 M _s_u_n, all significantly excluding M _B_H = 0. For NGC 3945, M _B_H = ...
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
Constrained least-squares techniques have been used to produce a well known class of image restoration algorithms. These techniques typically involve minimizing a linear operator on a vector representation of an image, subject to a constraint. For cases where an equality constraint is appropriate the method of Lagrange multipliers can be used to produce a restored image. In this work a fractal textural model, fractional Brownian motion, is used to represent images of interest. Using a variance fractal dimension estimator a non-linear operator, that represents the squared difference between the fractal dimension of the restored image and on a priori value is minimized, subject to the constraint that the norm of the residual between the restored image and available measurement equal the norm of the additive noise.
Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitized image version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and effectiveness of our approach for an efficient ...
The brain imaging properties of /sup 99m/Tc glucoheptonate, /sup 99m/Tc pertechnetate, and /sup 99m/Tc DPTA are compared. Results demonstrate that optimum images are obtained at 90, 180, and 180 min., for /sup 99m/Tc GH, /sup 99m/Tc DTPA, and /sup 99m/Tc pertechnetate, respectively. The former two images are not affected by prior bone imaging with /sup 99m/Tc pyrophosphate, while /sup 99m/Tc pertechnetate images are adversely affected. /sup 99m/Tc glucoheptonate appears to be the superior agent for brain imaging, followed by /sup 99m/Tc DTPA and /sup 99m/Tc pertechnetate.
Abstract Rationale, aims and objectives- Finding ways to incorporate disparate types of evidence into research syntheses has the potential to build a better evidence base for clinical practice and policy. Yet conducting such mixed research synthesis studies is challenging. Researchers have to determine whether and how to use adjusted and unadjusted quantitative findings in combination with each other and with qualitative findings. Methods- Among quantitative findings, adjustment for confounding, either via study design or statistical analysis, can be a considerable source of heterogeneity. Yet there is no consensus about the best way to synthesize findings resulting from different methods for addressing confounding. When synthesizing qualitative and quantitative findings, additional consid...
A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.
Gallium imaging is increasingly being used for the early detection of complications in patients with AIDS. A 26-year-old homosexual man who was HIV antibody positive underwent gallium imaging for investigation of possible Pneumocystis carinii pneumonia. Widespread cutaneous focal uptake was seen, which was subsequently shown to be due to mycobacterium avium-intracellulare (MAI) septicemia. This case demonstrates the importance of whole body imaging rather than imaging target areas only, the utility of gallium imaging in aiding the early detection of clinically unsuspected disease, and shows a new pattern of gallium uptake in disseminated MAI infection.
Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in ...
X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast ...
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...
In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation ...
Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and ...
Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...
Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
Twenty patients with lesions in the trachea or bronchus underwent energy subtraction Fuji computed radiography (FCR). Images obtained were compared with those from conventional FCR (plain FCR). ''Very clear'' images (in which the contour of the trachea and bronchus could be clearly defined) were obtained in 12/22 (55 %) by energy subtraction FCR and in 3/22 (14 %) by plain FCR; ''clear'' images (in which the contour could be defined) in 9/22 (41 %) by energy subtraction FCR and in 18/22 (82 %) by plain FCR; and ''unclear'' images (in which the contour could not be defined) in 1/22 (5 %) by both methods. Energy subtraction FCR, as well as plain FCR, yielded high image quality for the trachea. Energy subtraction FCR was superior to plain films when tumors existed within the trachea. (Namekawa, K.).
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).
A multiprocessor architecture inspired by the Disney multiplane camera is proposed. For many applications, this approach produces a natural mapping of processors to objects in a scene. Such a mapping promotes parallelism and reduces the hidden-surface work with minimal interprocessor communication and low-overhead cost. Existing graphics architectures store the final picture as a monolithic entity. The architecture here stores each object's image separately. It assembles the final composite picture from component images only when the video display needs to be refreshed. This organization simplifies the work required to animate moving objects that occlude other objects. In addition, the architecture has multiple processors that generate the component images in parallel. This further shortens the time needed to create a composite picture. In addition to generating images for animation, the ...
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).
This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...
An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more ...
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of ...
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best ...
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...
Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...
Which imaging modalities are appropriate for the Differential diagnosis of Rheumatic diseases. MRI has far most the highest sensitivity and is unequaled in its brilliant presentation of Anatomy and Pathology. But it is sometimes forgotten, that this is at least in part the result of carefully selected sequences, dedicated to the expected result. In a method totally independent of any result, this should not be the case. In contrary this method should be highly standardised and regardless what will be the findings. This is true for Plain X-ray. It will be shown, that already the outer silhouette of the soft parts with different features of swelling, and differences in density and even more - defects or appositions of the bony silhouette in the majority of cases at least will allow to classify the patient for a group of diseases and in many cases will lead to a definite diagnosis. Differential diagnoses like Rheumatoid Arthritis versus Psoriatic ...
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...
Power system analysis shows the output from the solar arrays varies as a function .... Each array corresponds to a raw image browse product, which is generated by .... low outgassing, ability to withstand long-term exposure to the space ...
Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to ...
Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available
Many simulation studies in biomedicine are based on a similar sequence of processing steps, starting from images and running through geometric model generation, assignment of tissue properties, numerical...Full Text Available
To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...
The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.
Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.
This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available
This review presents a summary of existing knowledge regarding the impact of testicular cancer along four broad domains, including romantic and sexual relationships, body image, and fertility....Full Text Available
Motivated by the observation that a retinal fundus image may contain some unique geometric structures within its vascular trees which can be utilized for feature matching, in this paper, we proposed...Full Text Available
ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available
Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available
Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available
An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available
To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe ...
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available
Cancer immunotherapies can be guided by cellular imaging techniques, which can identify the presence or absence of immune-cell accumulation in the tumor tissue in-vivo and in real time. This...Full Text Available
OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available
BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available
This volume contains the proceedings of a symposium entitled In Vivo Imaging of Neurotransmitter Function in Brain, Heart, and Tumors'' held August 24--25, 1990 in Montreal Canada. The six individual papers contained herein are separately abstracted and indexed for the database.
BACKGROUND: Although the importance of lymphatic function is well recognized, the lack of real-time imaging modalities limits our understanding of its role in many diseases. In a phase...Full Text Available
Background and Objectives:Sound enamel manifests peak transparency in the near-IR (NIR) at 1310-nm, therefore the near-IR is ideally suited for high contrast imaging...Full Text Available
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...
RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available
A two-channel optical system has been developed to provide spatially resolved simultaneous imaging of singlet molecular oxygen (1O2) phosphorescence and photosensitizer (PS) fluorescence...Full Text Available
The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique...Full Text Available
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...
This paper hopes to share the insights we experienced during designing, building, and running an indexing solution for a large set of radiological reports and images in a production environment for...Full Text Available
Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available
Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available
Functional imaging has revolutionized the neurosciences. In the pain field it has dramatically altered our understanding of how the brain undergoes significant functional, anatomical and chemical changes...Full Text Available
The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available
Antisense radiopharmaceuticals could be used to image gene expression in the brain in vivo, should these polar molecules be made transportable through the blood–brain barrier....Full Text Available
A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available
We studied 64 ADHD children patients group (4 {approx} 15 ys, mean age: 8 {+-} 2.6 ys. M/F: 52/12) and 12 normal group (6 {approx} 7 ys, mean age: 9.4 {+-} 3.4 ys, M/F: 8/4) of the brain had been used to analysis of blood flow between normal and ADHD group. For analysis of Children ADHD, we used 12 children's mean brain images and made Template image of SPM99 program. In crease of blood flow (P-value 0.05), the result of normalized images to Template image to offer from SPM99 program, showed significant cluster in inter-Hemispheric and occipital Lobe, in the case of normalized images to children template image, showed inter-hemispheric and parietal lobe.
Software for gel image analysis and base-calling in fluorescence-based sequencing consisting of two primary programs, BaseFinder and GelImager, is described. BaseFinder is a framework for trace processing,...Full Text Available
BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available
Computed Tomography (CT) and, more recently, ultrasound (US), have proved excellent tools for quantifying adipose tissue distribution. Body fat distribution is an important factor in the treatment of obesity and its complications. In this work it is investigated the correlation between CT and US measurements in pediatric obesity. Forty obese children and adolescents aged 4.1-14.8 years were submitted to CT and US. Intra-abdominal, subcutaneous and total body fat were calculated (in cm{sup 2}), with the CT image analysis software. The rectus muscle-spine and rectus muscle-aorta distances, as indicative of visceral fat thickness, were measured on US images with(out) compression. The distance between skin fat and fat-rectus muscle interfaces was measured as subcutaneous fat thickness. US-CT findings have been compared with other morphometric variables-i.e., patient's (ideal) body weight and skin fold measures. A ...
PurposeTo describe ocular findings for a 34-year-old man with chronic solar retinopathy using high-speed ultrahigh-resolution (UHR) optical coherence tomography (OCT).Full Text Available
This study examines the results of bacterial culture from 159 endometrial biopsy samples from 97 commercial dairy cows and correlations between bacteriological and histological findings. Bacteria were...Full Text Available
The cytogenetic findings were analysed in a series of 500 pregnancies in which chorionic villi sampling was performed. In all cases a direct method was used, karyotyping being successful in 481 cases...Full Text Available
Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).
The patch and voxel methods are representative examples of the ways in which multi-slice images may be displayed three-dimensionally by means of computer-graphics. Each of them have advantages and disadvantages and they are mutually complementary. We have developed algorithms for a modified voxel method which incorporates the advantages of the patch methods. We have applied this to the three-dimensional image display of brain tumor with excellent results. The three-dimensional reconstructions used for clinical application in this study were derived from X-ray CT images.
The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.
Disaster impact modeling and analysis uses huge volumes of image data that are produced immediately following a natural or an anthropogenic disaster event. Rapid damage assessment is the key to time critical decision support in disaster management to better utilize available response resources and accelerate recovery and relief efforts. But exploiting huge volumes of high resolution image data for identifying damaged areas with robust consistency in near real time is a challenging task. In this paper, we present an automated image analysis technique to identify areas of structural damage from high resolution optical satellite data using features based on image content.
There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging
Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-guided biopsies, aspirations and small bore chest drain placement, all of which have been shown to be safe and efficacious. Pneumothoraces occurring due to acute trauma and in an intensive care setting can also benefit from radiological input, both in terms of diagnosis and image-guided treatment. (orig.)
Multitemporal TM images are used to collect information about the extension and variation of water influx subsidence in coal district in order to provide a reference for the harnessing and utilization of water influx subsidence. The multitemporal TM images are used as a blended data group for the analysis of the principal components to reflect the expanding water influx subsidence in the past years. Because of the differences in the environment and imaging condition, 'unitary' order is used to enhance the 'coherence' and 'comparability' of the original TM images. 5 refs., 4 figs., 2 tabs.
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
A carbon nanotube (CNT) tip, which assembled on the sharp end of a Si tip by dielectrophoresis, was structurally modified using focused ion beam (FIB). We described the imaging characterization of the FIB-modified CNT tip in noncontact AFM mode in terms of wear, deep trench accessibility, and imaging resolution. Compared to a conventional Si tip, the FIB-modified CNT tip was superior, especially for prolonged scanning over 10 h. We conclude that modified CNT tips have the potential to obtain high-quality images of nanoscale structures.
... is the sensor that converts incoming photons into a ... with CCD foundries to acquire such a sensor. ... 2007, Journal of Spacecraft and Rockets, 44, 910 ...
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
ARIES Baker-Nunn Schmidt telescope project is converting a Baker-Nunn satellite tracking camera for Astronomical research. Original Baker-Nunn camera produces an extremely large (5X30 degree) curved focal plane at the prime focus for photographic imaging. We present here the re-designing of the camera produces a wide (4 X 4 degree) flat field of view for CCD imaging observations, which have many scientific potentials in Astronomy. Imaging performance of the CCD camera is also estimated.
This book constitutes the thoroughly refereed post proceedings of the international workshop Computer Vision Approaches to Medical Image Analysis, CVAMIA 2006, held in Graz, Austria in May 2006 as a satellite event of the 9th European Conference on Computer Vision, EECV 2006. The 10 revised full papers and 11 revised poster papers presented together with 1 invited talk were carefully reviewed and selected from 38 submissions. The papers are organized in topical sections on clinical applications, image registration, image segmentation and analysis, and the poster session. (orig.)
Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).
The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....
... order probabilistic modelling, multisensor monitoring of ... object recognition, image registration and point ... of the Berkeley Continuous Media Toolkit. ...
Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in predicting vascularity after femoral neck ...
Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in predicting vascularity after femoral neck ...
Identification of factors that determine individual patient risk for recurrence and progression in superficial papillary carcinoma of the bladder is a subject of extensive research as it would be a major outcome in patient management. It has been well recognized that traditional prognostic markers as tumor grade and stage are not accurate enough in predicting biological behavior. A large number of markers have been investigated as potential prognostic factors and relatively few can help in predicting outcome. Material and Methods: Forty-nine cases undergoing complete transurethral resection for primary superficial papillary transitional cell carcinoma were subjected to clinicopathologic evaluation as well as immunohistochemical staining for p53, bcl-2, cytokeratin 20 and Ki-67. The CAS-200 image analyzer was used to estimate the Ki-67 labeling index. Results: Recurrence was observed in 19 cases (38.8%) and progression in 7 cases (14.3%) with a median followup of 49 ...
A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T{sub 1}- and T{sub 2}-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG) [Deutsch] In einer prospektiven Studie an 50 Patienten mit einer Osteochondrosis dissecans (OD) des ...
To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response evaluation criteria in solid tumors criteria. Response on PET-CT was ...
We adapt the Jain-Taylor (2003) shear-ratio geometric lensing method to measure the dark energy equation of state, w = pv/?v and its time derivative from dark matter haloes in cosmologies with arbitrary spatial curvature. The full shear-ratio covariance matrix is calculated for lensed sources, including the intervening large-scale structure and photometric redshift errors as additional sources of noise, and a maximum likelihood method for applying the test is presented. Decomposing the lensing matter distribution into dark matter haloes we calculate the parameter covariance matrix for an arbitrary experiment. Combining with the expected results from the cosmic microwave background (CMB) we design an optimal survey for probing dark energy. This shows that a targeted survey imaging 60 of the largest clusters in a hemisphere with five-band optical photometric redshifts to a median galaxy depth of zm = 0.9 could measure w0 ? w(z = 0) to a marginal 1? error of ?w0 = ...
60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A brilliant MR-tomographic imaging of the small bowel is possible under the condition, that the small bowel contrast is optimal. The ...
... of the utility of the terminal outcomes, ... Other stochastic topics, such as random walks, branching ... find special uses, particularly in queueing theory ...
This article considers the appeal of cognitive neuroscience research to the general public within the context of the deep puzzles involved in using our minds to understand how our minds work. It offers a few promising examples of findings that illuminate the ways of the mind and reveal these workings to be counter-intuitive with our subjective experience. However, this promise is tempered by the powerful role that perception, attention, and cognition play in how we reason about evidence. It argues that the interplay between what we believe about the nature of our minds and what the findings suggest constitutes a primary challenge in encouraging public understanding of cognitive neuroscience findings.
...Surface Aerators Products and Equipment Find and compare a variety of surface aerators products and equipment on the world's largest environmental industry portal. ...
...Extraction Arms Products and Equipment Find and compare a variety of extraction arms products and equipment on the world's largest environmental industry portal. ...
... Tunnel Composting Products and Equipment Find and compare a variety of tunnel composting products and equipment on the world's largest environmental industry portal. ...
... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...
Purpose of reviewTo summarize recent advances in the classification of preradiographic axial spondyloarthritis (SpA).Recent findingsFull Text Available
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)
Parathyroid imaging based on the principle of differential uptakes of Tc-99m and T1-201 in the anterior neck to localize parathyroid (PT) disease has been reported with widely varying results. To evaluate the usefulness of this method, we have performed PT imaging on 47 patients prior to exploratory surgery for PT disease. Using pinhole collimation and digital acquisition, a 50k count image of the thyroid was obtained 20 minutes after injection of 1mCi99m Tc-pertechnetate. Then a lmCi dose of Tl-201 chloride was injected and a series of images acquired for 30 minutes at 30 sec/image. Raw data was spatially filtered and normalized by summing sufficient T1-201 images to equal the Tc-99m image scale of maximum cts/pixel. Image subtraction (Tl-Tc) gave the final PT image. Of 10 pts who had previous neck ...
Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.
For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
In this article, the authors recall the factors apt to influence image quality in NMR Imaging and present the european works that have been developed in MRIQA to set 5 quality assurance tests: EUROSPIN 1 to 5.
Sponsored by the Defense Advanced Research Projects Agency the Image Understanding Workshop is a forum for the presentation of new research in vision, image analysis, and geometric modeling. Leading scientists present overviews of projects underway at major universities and corporate research sites, as well as results of individual work. The 1987 volume contains 94 articles and technical reports in two volumes.
The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper
This manuscript reviews some of the more controversial dose-related issues in cardiac CT imaging. Discussion covers the relative merits of cardiac CT versus MR, advantages and concerns regarding gated versus nongated cardiac CT and advantages and concerns regarding the use of breast shields in girls undergoing cardiac CT imaging.
Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).
The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).
An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.
A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.
A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available
We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).
The authors report an extension of the source imaging method for analyzing three-dimensional sources from three-dimensional correlations. The technique consists of expanding the correlation data and the underlying source function in spherical harmonics and inverting the resulting system of one-dimensional integral equations. With this strategy, they can image the source function quickly, even with the extremely large data sets common in three-dimensional analyses.
We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)
In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.
Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available
This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.
Various topics include: (1) direction finding, (2) range finding, (3) Doppler measurements, (4) construction of a receiver for radio interferometry, (5) mobile laser range finding system, (6) figure-and field parameter determination/geopotential, (7) dynamics of the Earth-Moon system, and (8) kinematics of geodetic point fields.