Described herein are the results of the FY1994 research program for analysis and evaluation for thin film solar cells. The study on quantitative analysis of hydrogen atoms in a plasma determines quantity of hydrogen atoms in the plasma of monosilane diluted with hydrogen. It is found, contrary to expectation, that quantity of hydrogen atoms in the plasma decreases as it is more diluted with hydrogen. The study on light-induced degradation of the thin chlorine-base amorphous silicon films confirms that the plasma CVD method with 20% of dichlorosilane gas added to monosilane gas produces the thin amorphous silicon film 3 times faster than the conventional method. The thin film has essentially the same defect density as the one prepared by the conventional method, showing good photoelectric characteristics. The thin film of chlorinated amorphous silicon has a 1 digit lower defect density than the conventional one of amorphous silicon, as revealed by the accelerated degradation test with ...
This paper reports the result obtained during fiscal 1994 on a demonstration research on photovoltaic power generating systems. Solar cells with an output of 750 kW, storage battery facilities with an output of 3,058 kWh, three DC-AC converters with a rating of 250 kW, and a diesel generator with an output of 300 kW having been installed up to the previous fiscal year were combined to perform comprehensive adjustments and tests such as battery charge/discharge tests and AC parallel operation tests. The battery charge/discharge tests revealed that the 10 hour rate discharge capacity meets the specifications, and the batteries are free of deterioration after a demonstration operation of about 4.5 months. Difference between the power generation record and the planned value is thought due to the following reasons: the array output data in a power line connected system come about 90% of the simulation result due to correction coefficient for the solar cell conversion efficiency; the ...
The R and D were carried out of a detecting system for measurement of data on the bottom of geothermal well, data transmission and signal processing, and an analysis system for well drilling trajectory control and well assessment while geothermal well drilling based on the data obtained by the detecting system. The paper reported the results of the technology development in fiscal 1996. In the development of the detecting system, improvement/design were conducted on a mud pulse generator constituting sonde, well bottom signal processing equipment, mode switch and inclined information sensor, and the system equivalent to the actual one was manufactured to conduct a running test at high temperature/pressure. Moreover, a test to confirm heat resistance of electronic parts was made for further improvement in heat resistance of the sonde, in order to obtain the data. In the development of an analysis system, conducted were enhancement of operability of the planning/indication portions of ...
Described herein are the results of the FY1994 research program for structural defects of silicon-based amorphous materials for solar cells. The study on light generation defects of the a-Si:H system and rejuvenation process by annealing establishes the effects of light irradiation time on changed neutral dangling bond density as a result of light irradiation at varying temperature of 77K, room temperature and 393K. The study on annealing to rejuvenate light generation defects of various types of a-Si-H systems establishes the activation energy distribution with respect to annealing to remove light-induced defects, showing that hydrogen affects the distribution of light-induced defects. The study on decaying process of light-induced ESR for undoped and N-doped a-Si:H systems observes the decaying process of light-induced ESR, after light is cut off, extending for a period of several seconds to several hours at 77K for the a-Si-H systems containing N in a range from 0 to 12at%. The ...
Inverter introduced in this paper is intended for use in medium-capacity photovoltaic power generation systems designed for industries in general. Interconnection is carried out at a low-voltage 210V point receiving from a commercial 3 phase-3 cable 6.6kV high voltage incoming panel. So as to ensure stable extraction of power in the maximum degree from a photovoltaic power generation system that is naturally unstable, this inverter monitors voltage and power, and behaves in a fully automated way. A maximum power point tracking (MPPT) control function is provided, which measures the power level at the current operating voltage point A, changes the operating voltage to a voltage value B which is lower than the point A voltage by 3V and to a voltage value C which is higher than the point A voltage by 3V, and measures the power level at each point. Comparison is then made between the values measured at the said points on a PV profile, and the operating voltage value is moved toward the C ...
Kawasaki Heavy Industries, Ltd. has developed a gas turbine combined cycle and cogeneration plant computer aided engineering (CAE) system, which creates cycle heat balance automatically on given configurations of gas turbines, heat recovery boilers, steam turbines and auxiliaries. The system can predict the performance of the plant as a function of control set points, loads, process steam requirements and ambient conditions, which enables accurate and fast design of gas turbine combined cycle and cogeneration plants. (author)
Introduced herein is microwave irradiation for the adsorption and desorption of environmental pollutants. Microwaves may be used in two ways, other than through elevation of temperature of a system as a whole with the adsorbent such as activated carbon serving as the heating medium. The first is the application by which desorption is caused to take place of specified molecules. For example, zeolite that has adsorbed water is regenerated when it is irradiated with microwaves in a stream of cooling gas. This is because only the moisture is heated since zeolite is a non-carbon adsorbent that absorbs microwaves but a little. Another case is reported in which microwaves are utilized to desorb H2S, H2O, CO, etc., from molecular sieves. In the second application, coexisting materials different in absorptivity are exposed to irradiation. The adsorption of microwave-absorbent materials is inhibited while that of the others is accelerated. For example, the adsorption of chlorofluorocarbon from a ...
A study was made for the purpose of electrification of unelectrified zones of the mountainous areas in developing countries using extremely small hydroelectric power facilities. The target for this project is a development of a micro hydroelectric power system with a size of about 5kW, which is estimated regarding that 1 village has 80 houses and each house needs electricity of 60W. In the study, the low-head system using a weir of irrigation channels in Subang pref. of West Java state was selected by the evaluation of access, stability of flow rate, natural conditions, etc. The hydroelectric power plant is of a flow-in method in which water is taken from the left bank and is injected/discharged to the downstream of the left bank. As the hybrid complementary power source, hybrid battery with a two-hour charging time at peak and a capacity of 3.5kWh was considered. When estimating the construction cost of the hybrid micro hydroelectric power system and equalizing by durable years, the ...
Feasibility study is conducted for introduction of a top pressure recovery turbine (TRT) in China's Panzhihua Iron and Steel (Group) Company, Sichuan Province, for the potential project to simultaneously contribute to abatement of the greenhouse effect gases and to sustainable economic development of the counterpart country. This project considers to adopt the TRTs in 3 blast furnaces (No.1 to 3) of the 4 furnaces in service at the works, producing 2,500,000 t/y of crude steel, where the No.4 furnace is already provided with the model system and not considered in this project. According to the feasibility study results, the total fund required is 5.46 billion yen (Japan-made facilities: 4.172 billion yen, and China-made facilities: 1.288 billion yen), energy-saving effect is 36,467 t/y as crude, greenhouse effect gas emission abatement effect: 112,830 t/y as CO2, and pay-off period is 8.3 years. This plan considers to adopt almost the same facilities as those for the model ...