The noninvasive assessment of cardiac function is of first importance for the diagnosis of cardiovascular diseases. Among all medical scanners only a few enables radiologists to evaluate the local cardiac...Full Text Available
Anti-TAG-72 monoclonal antibodies target the tumor-associated glycoprotein (TAG)-72 in various solid tumors. This study evaluated the use of anti-TAG-72 monoclonal antibodies, both murine CC49...Full Text Available
This manuscript reviews some of the more controversial dose-related issues in cardiac CT imaging. Discussion covers the relative merits of cardiac CT versus MR, advantages and concerns regarding gated versus nongated cardiac CT and advantages and concerns regarding the use of breast shields in girls undergoing cardiac CT imaging.
Current multi-scale computational models of ventricular electromechanics describe the full process of cardiac contraction on both the micro- and macro- scales including: the depolarization of cardiac cells, the release of calcium from intracellular stores, tension generation by cardiac myofilaments, and mechanical contraction of the whole heart. Such models are used to reveal basic mechanisms of cardiac contraction as well as the mechanisms of cardiac dysfunction in disease conditions. In this paper, we present a methodology to construct finite element electromechanical models of ventricular contraction with anatomically accurate ventricular geometry based on magnetic resonance and diffusion tensor magnetic resonance imaging of the heart. The electromechanical model couples detailed repres...
A high-speed fiber-based network for the transmission and display of digitized full-motion cardiacimages has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available
Libman-Sacks endocarditis is a well-known and rather common cardiac manifestation of systemic lupus erythematosus. Transesophageal and transthoracic echocardiography are the definitive imaging methods...Full Text Available
The profusion of online digital images presents new challenges for image indexing. Images have always been problematic to describe and catalogue due to lack of inherent textual data and ambiguity of meaning. An alternative to time-consuming professionally-applied metadata has been sought in the form of tags, simple keywords that form a flat structure known as distributed classification, or more popularly as a folksonomy. This research aims to increase understanding of why people tag and how effective they find it for searching, using as the focus. Open-ended questionnaires were sent out to members of the photo-sharing website Flickr, with the opportunity to post comments to an online discussion space. There is also a systematic comparison between a tag-based system and a more traditional controlled vocabulary, to test out the claims made regarding the ...
... stenosis. It looks from the transesophageal and the 3-D echo that most of the problem is really ... posterior leaflet, which you can see on the 3-D echo image is a major source. The anterior ...
ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available
Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance ...
The aim of this study was to compare a 1-day with a 2-day iodine bowel preparation for CT colonography in a positive faecal occult blood test (FOBT) screening population. One hundred consecutive patients underwent CT colonography and colonoscopy with segmental unblinding. The first 50 patients (group 1) ingested 7*50 ml iodinated contrast starting 2 days before CT colonography. The latter 50 patients (group 2) ingested 4*50 ml iodinated contrast starting 1 day before CT colonography. Per colonic segment measurements of residual stool attenuation and homogeneity were performed, and a subjective evaluation of tagging quality (grade 1-5) was done. Independently, two reviewers performed polyp and carcinoma detection. The tagging density was 638 and 618 HU (p = 0.458) and homogeneity 91 and 86 HU for groups 1 and 2, respectively (p = 0.145). The tagging quality was graded 5 (excellent) in 90% of all segments in group 1 and 91% ...
The purpose of this paper is to investigate the influence of diabetic myocardial damage (suspected myocardial damage; SMD) diagnosed by [sup 201]Tl-SPECT and diabetic cardiac autonomic neuropathy (AN) on myocardial MIBG uptake in patients with NIDDM. Eighty-seven diabetic patients divided into four subgroups: 23 with SMD (+) AN (+); 19 with SMD (+) AN (-); 27 with SMD (-) AN (+); 18 with SMD (-) AN (-), and 10 controls were studied. Both planar and SPECT images were taken at 30 minutes (early) and 3 hours (delayed) after [sup 123]I-MIBG injection. The heart to mediastinum uptake ratio (H/M) and washout ratio of [sup 123]I-MIBG (WR) were obtained from both planar images. Similarly, the difference between the [sup 201]Tl image and the [sup 123]I-MIBG image in the total uptake score (TUS) was taken as the difference in the total uptake score ([Delta]TUS) representing ...
The relative sensitivity and combined value of myocardial technetium-99m stannous pyrophosphate imaging and determinations of serum MB creatine phosphokinase (the ''myocardial'' CPK isoenzyme) in detecting acute myocardial infarction were evaluated in 41 patients with suspected infarction and 23 patients recovering from cardiac surgery. In the patients with suspected infarction, myocardial infarction was confirmed in 25 and was consistently associated with increased serum MB CPK. Abnormal radionuclide images were obtained in 23 of 25 patients (92%)) with definite myocardial infarction and in 2 of 16 patients without confirmed infarction. Although the localization of infarction by imaging correlated well with the localization by electrocardiogram, infarct size estimated by imaging did not correlate well with estimates based on peak total serum CPK activity or serial changes in CPK ...
The location of defective LMFBR fuel pins by the determination of gas tag isotopic ratios is discussed. The application of this method to the FFTF Reactor briefly described.
Objectives:The efficacy of user-defined subject tagging and software-generated subject tagging for describing and organizing cancer blog contents was explored.Methods:The...Full Text Available
The aim of the study was the attempt to evaluate the influence of two different methods of cardiac perfusion SPECT reconstruction (FBP and ITW) on clinical efficacy in diagnosing the coronary artery disease as well as the cardiac ischemia detection in three areas of heart vascularized by main coronary arteries: LAD, LCX and RCA with the use of artificial neural networks (ANN). The study was performed retrospectively with the use of the diagnostic image records as well as clinical dataset of 43 patients. Myocardial perfusion stress/rest SPECT study and X-ray coronarography data were evaluated for each patient. The results of coronary angiography were considered the reference method. The cardiac SPECT data were reconstructed using the two different methods: filtered backprojection (FBP) and iterative Wallis method (ITW). The local perfusion deficits denominated in stress and rest study in three main ...
... and Cardiac Function test (including optional measurements of central venous pressure (CVP), via a peripherally inserted central catheter, and cardiac output ...
Primary cardiac angiosarcoma is a rare cardiac tumor. The initial clinical course is often asymptomatic, and metastatic disease is present in a majority of affected patients at diagnosis. We present...Full Text Available
BackgroundIsoproterenol-induced cardiac hypertrophy in mice has been used in a number of studies to model human cardiac disease. In this study, we compared the transcriptional response...Full Text Available
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...
Lanthanide-ion doped oxide nanoparticles were functionalized for use as fluorescent biological labels. These nanoparticles are synthesized directly in water which facilitates their functionalization, and are very photostable without emission intermittency. Nanoparticles functionalized with guanidinium groups act as artificial toxins and specifically target sodium channels. They are individually detectable in cardiac myocytes, revealing a heterogeneous distribution of sodium channels. Functionalized oxide nanoparticles appear as a novel tool particularly well adapted to long-term single-molecule tracking.
Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron ...
We examined the subcellular localization of ryanodine receptors (RyR) in the cardiac muscle of carp using biochemical, immunohistochemical, and electron microscopic methods and compared it with those of rats and guinea pigs. To achieve this goal, an anti-RyR antibody was newly raised against a synthetic peptide corresponding to an amino acid sequence that was conserved among all sequenced RyRs. Western blot analysis using this antibody detected a single RyR band following the SDS-PAGE of sarcoplasmic reticulum (SR) membranes from carp atrium and ventricle as well as from mammalian hearts and skeletal muscles. The carp heart band had slightly greater mobility than those of mammalian hearts. Although immunohistochemical staining showed evident striations corresponding to the Z lines in longitudinal sections of mammalian hearts, clusters of punctate staining, in contrast, were distributed ubiquitously throughout carp atrium and ventricle. Electron microscopic ...
Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate ...
Increasingly, business projects are ephemeral. New Business Intelligence tools must support ad-lib data sources and quick perusal. Meanwhile, tag clouds are a popular community-driven visualization technique. Hence, we investigate tag-cloud views with support for OLAP operations such as roll-ups, slices, dices, clustering, and drill-downs. As a case study, we implemented an application where users can upload data and immediately navigate through its ad hoc dimensions. To support social networking, views can be easily shared and embedded in other Web sites. Algorithmically, our tag-cloud views are approximate range top-k queries over spontaneous data cubes. We present experimental evidence that iceberg cuboids provide adequate online approximations. We benchmark several browser-oblivious tag-cloud layout optimizations.
To gain insight into the changes in the transcriptome of soybean roots during soybean cyst nematode (SCN) infection, we conducted genome-wide gene expression profiling using serial analysis of gene expression (SAGE) combined with Solexa sequencing. More than 3 million tags were generated from the SCN-infected and uninfected roots, and 366941 and 314591 clean UniTags were obtained from SCN-infected and uninfected samples, respectively. In the SCN-infected sample, 48249 UniTags represented 18114 reference genes. In the uninfected control, 46290 UniTags represented 19323 reference genes. Comparison of tag frequencies identified 1405 genes that were expressed at greater levels in SCN-infected roots than in uninfected roots, and 1191 genes that were expressed at lower levels. Quantitative real-...
Increasingly, business projects are ephemeral. New Business Intelligence tools must support ad-lib data sources and quick perusal. Meanwhile, tag clouds are a popular community-driven visualization technique. Hence, we investigate tag-cloud views with support for OLAP operations such as roll-ups, slices, dices, clustering, and drill-downs. As a case study, we implemented an application where users can upload data and immediately navigate through its ad hoc dimensions. To support social networking, views can be easily shared and embedded in other Web sites. Algorithmically, our tag-cloud views are approximate range top-k queries over spontaneous data cubes. We present experimental evidence that iceberg cuboids provide adequate online approximations. We benchmark several browser-oblivious tag-cloud layout optimizations.
Purpose: To quantify left ventricular function derived from retrospectively ECG-gated multislice spiral CT (MSCT) data sets in comparison to MRI. Materials and Methods: In 16 patients (14 males, 2 females, mean age 56.8 #+-# 11.5 years), retrospectively ECG-gated MSCT angiography of the coronary arteries and breath-hold steady state free precession cine MRI were performed. From MSCT data-sets, 20 axial image series were reconstructed every 5% of the RR interval. Multiplanar images were reformatted in the short axis orientation from axial images. End-systolic and end-diastolic images were selected. From these images end-systolic volume (ESV), end-diastolic volume (EDV) and stroke volume (SV) as well as the ejection fraction (EF) and myocardial mass (MM) were determined using the Simpson's method and compared with MRI. Furthermore, image quality was assessed for ...
Phospholemman (PLM), a member of the FXYD family of regulators of ion transport, is a major sarcolemmal substrate for protein kinases A and C in cardiac and skeletal muscle. In the heart, PLM...Full Text Available
A field study of 89 refrigerator repairmen was carried out to ascertain whether occupational exposure to fluorocarbons induces cardiac arrhythmia. The concentrations of fluorocarbons in the breathing...Full Text Available
Diagnostic accuracy of the currently available serum markers of cardiac injury, such as myoglobin, creatine kinase and its myocardial isoform, are altered in patients with renal failure. It is shown...Full Text Available
The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8-8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two observers correctly ...
[sup 123]I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy was performed in 20 diabetic patients (NIDDM) and 8 control subjects to investigate the association between clinical autonomic nerve dysfunction and myocardial accumulation of MIBG. We used coefficient variance of R-R interval (CV[sub R-R]) as a index of the autonomic neuropathy and categorized diabetes into two groups (CV[sub R-R][>=]2.0: non-autonomic neuropathy. CV[sub R-R]<2.0: autonomic neuropathy). In planar imaging studies, heart to mediastinum MIBG uptake ratio (H/M) was calculated on both early and delayed images. The washout ratio of [sup 123]I-MIBG in the heart (%WR) was also obtained using myocardial tracer activity on the both images. Mean value of these indices in diabetic group did not reveal any significant difference with the value in the control group. On the SPECT images, low uptake was observed in the ...
Eleven patients who had undergone cardiac surgery were studied by means of high-field MR imaging (1.5 T). Six patients had aortic root and valve replaced with a Bjork-Shiley (BS) composite tubular aortic graft prosthesis for acute dissection of ascending aorta. In the other 5 patients with rheumatic calcific aortic disease, the valve had been replaced with a BS prosthesis. As a whole, MR studies were 14. Previous evaluations of magnetic field effects had seem carried out ex vivo on both BS valves and BS composite prostheses, on surgical ligation clips (Tantalium and Stainless) and on stainless wires for sternal closure. In 4 patients (2 BS composite grafts, and 2 BS valves) MRI diagnosed chronic dissection of both arch and descending aorta. In 1 of them, with a bs valve, associated localized acute dissection of ascending aorta was observed. In 3 patients with BS composite grafts, MRI revealed pseudo-aneurysms (including a thrombosed one) at the ...
Quantitative gated SPECT (QGS) was evaluated in 7 normal volunteers and 31 patients with cardiac diseases. Adequate cut off value of a prefilter was 0.45. In phantom, the left ventricular volume value was 93.9% of determined value by 180-degree projection in L type and 98.8% by 360-degree projection in opposed type. In normal volunteers, LVEF measured by QGS program related to value by first pass method. As for functional map, regional EF and wall motion decreased at the septum side, and wall thickening at base side of heart. Good correlation was recognized (p<0.0001) between blood flow image and functional map (regional EF and wall thickening). In 20 cases of acute myocardial infarction, lesion was detected conspicuously in regional EF and wall motion. The accuracy of coronary arterial stenosis improved in functional map (regional EF 92%, wall motion 92% and wall thickening 88%). In particular, the accuracy of 3 rami lesion was 100% in ...
The purpose of this work was to develop and evaluate a method of locating breached fuel within the Fast Flux Test Facility (FFTF) reactor based on the relative response of the delayed neutron monitors (DNM) located on each of the three primary sodium cooling loops. The primary method of location is the use of tag gas containing unique ratios of the noble gases xenon and krypton. Although the tag gas system works quite well, it is relatively expensive because of the costs of preparing and loading the gas into each fuel pin. Triangulation of DNM signals could potentially decrease tag gas costs while maintaining overall location reliability.
Mar 15, 2010... Boulder have demonstrated that a five-nucleotide-long ribozyme can ... animals anoxia anoxia biomarker permian cambrian terrestrial ...
For the preparation of photonic probes for hadron physics the determination of energy and polarization of the photons is essential. In this dissertation in a first part a possibility of the determination of the degree of polarization by use of the asymmetry observables is presented. In a second part a possibility isd discussed to perform an energy and polarization tagging of nearly real photons in electron scattering under small Q{sup 2}. By this method it should be possible to tag billions of photons per second.
We discuss an experimental technique aimed at tagging electron neutrinos in multi-GeV artificial sources on an event-by-event basis. It exploits in a novel manner calorimetric and tracking technologies developed in the framework of the LHC experiments and of rare kaon decay searches. The setup is based on an instrumented decay tunnel equipped with tagging units that intercept secondary and tertiary leptons from the bulk of undecayed pi+ and protons. We show that the taggers are able to reduce the nue contamination originating from K_e3 decays by about one order of magnitude. Only a limited suppression (~60%) is achieved for nue produced by the decay-in-flight of muons; for moderate beam powers, similar performance as for K_e3 can be reached supplementing the tagging system with an instrumented beam dump.
To establish the optimum barium-based reduced-laxative tagging regimen prior to CT colonography (CTC). Ninety-five subjects underwent reduced-laxative (13 g senna/18 g magnesium citrate) CTC prior to same-day colonoscopy and were randomised to one of four tagging regimens using 20 ml 40%w/v barium sulphate: regimen A: four doses, B: three doses, C: three doses plus 220 ml 2.1% barium sulphate, or D: three doses plus 15 ml diatriazoate megluamine. Patient experience was assessed immediately after CTC and 1 week later. Two radiologists graded residual stool (1: none/scattered to 4: >50% circumference) and tagging efficacy for stool (1: untagged to 5: 100% tagged) and fluid (1: untagged, 2: layered, 3: tagged), noting the HU of tagged fluid. Preparation was good (76-94% segments graded 1), although best for regimen D (P = 0.02). Across all regimens, stool ...
It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have ...
A vessel phantom suitable for evaluation of spatial and contrast resolution of FCRDSA (Fuji Computed Radiography, digital subtraction angiography) has been developed and used for determining resolution. The effects of iodine concentration, low dose exposure, and acryl thickness on the resolution were evaluated in FCRDSA, and FCRDSA images were compared with film substraction with use of this phantom. It has been proven that limitation of resolution of FCRDSA was 5 % 1 mm and about 1/4 dose exposure compared with conventional film exposure was clinically acceptable. Dye dilution method was useful to determine a program of IVDSA with imaging plate. It has been proven that time to appearance and time to peak of time-concentration curve of dye dilution method closely correlate to time to appropriate image of DSA in the neck, the chest, and the abdomen. 106 cases of IVDSA and 130 cases of IADSA using FCR in Tohoku University ...
Cellular calcium transient alternans are beat-to-beat alternations in the peak cytosolic calcium concentration exhibited by cardiac cells during rapid electrical stimulation or under pathological conditions....Full Text Available
How an individual’s sex and genetic background modify cardiac adaptation to increased workload is a topic of great interest. We systematically evaluated morphological and physiological...Full Text Available
Experiments were carried out to determine whether platelet aggregation plays a primary role in cardiac allograft hyperacute rejection, as has been observed in renal allograft hyperacute rejection....Full Text Available
Chest compression-only (CC-only) is now incorporated in the Norwegian protocol for dispatch guided CPR (cardiopulmonary resuscitation) in cardiac arrest of presumed cardiac aetiology.We present...Full Text Available
The intercalated disk (ID) is a complex structure that electromechanically couples adjoining cardiac myocytes into a functional syncitium. The integrity of the disk is essential for normal cardiac function,...Full Text Available
Cardiovascular modelling has been a major research subject for the last decades. Different cardiac models have been developed at a cellular level as well as at the whole organ level. Most of...Full Text Available
The receptors for IGF-I (IGF-IR) and insulin (IR) have been implicated in physiological cardiac growth, but it is unknown whether IGF-IR or IR signaling are critically required. We generated mice with...Full Text Available
Tumor embolism occurs in 30 to 50% of all cases of cardiac myxoma, but the causes are still uncertain. Matrix metalloproteinases (MMPs) are proteolytic enzymes that degrade the extracellular matrix...Full Text Available
Acute myocardial infarction (AMI) is a common cause of death for which effective treatments are available provided that diagnosis is rapid. The current diagnostic gold standards are circulating cardiac...Full Text Available
Background:The cardiac sodium–calcium exchanger (NCX1) is a key sarcolemmal protein for the maintenance of calcium homeostasis in the heart. Since heart failure...Full Text Available
BackgroundElevated cardiac troponin I (cTnI) is frequently observed in patients with severe sepsis and septic shock. However, the mechanisms underlying cTnI release in these patients...Full Text Available
1. The effects of 1 mg/ml whole Naja nivea (Cape cobra) venom, and of three different toxins isolated from it, on spinal reflex excitability and cardiac and skeletal muscle activity...Full Text Available
Myocarditis, often initiated by viral infection, may progress to autoimmune inflammatory heart disease, dilated cardiomyopathy and heart failure. Although cardiac myosin is a dominant autoantigen...Full Text Available
Anxiety may cause adverse outcomes through physiologic pathways in patients with cardiac disease. The purpose of this dissertation was to investigate anxiety and its correlates in persons with acute myocardial infarction (AMI) and heart failure (HF). The ...
ObjectiveThe objective of this study was to determine the contribution of distance to hospitals with cardiac interventional services (CIS) to county age-adjusted myocardial infarction...Full Text Available
Physiological cardiac hypertrophy is associated with mitochondrial adaptations that are characterized by activation of PGC-1α and increased fatty acid oxidative (FAO) capacity. It is...Full Text Available
The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue valves in our one-day ...
The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the ...
The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the ...
Feb 11, 1997 ... Dr. Baldwin's research focuses on understanding the mechanisms of skeletal and cardiac muscle adaptations to hormonal and activity ...
Aim: To evaluate the usefulness of routine laboratory parameters in the decision to treat refractory cardiac arrest patients with extracorporeal life support (ECLS). Methods: Sixty-six adults with witnessed cardiac arrest of cardiac origin unrelated to poisoning or hypothermia undergoing cardiopulmonary resuscitation without return of spontaneous circulation (duration: 155min [120-180], median, [25-75%-percentiles]) were included in a prospective cohort-study. ECLS was implemented under cardiac massage, using a centrifugal pump connected to a hollow-fiber membrane-oxygenator, aiming to maintain ECLS flow >=2.5l/min and mean arterial pressure >=60mmHg. Results: Forty-seven of 66 patients died within 24h from multiorgan failure and massive capillary leak. Of 19/66 patients who survived >=24h...
The Fast Flux Test Facility (FFTF) is a 400 MW(th) sodium cooled reactor and is the largest test reactor of its type in the world. It was designed and is being operated to serve two purposes: gaining liquid metal system experience and serving as a test bed for fuels and materials. During test operations it is possible that cladding breaches and escape of fission gas to the reactor cover gas region can occur. To identify the source of such a leak all 78 fuel pin assemblies contain ''gas tag'' with a unique ''tag'' mixture in each assembly. The mass spectrometric identification of tag isotope ratios makes possible rapid location and thus faster removal (if required) of breached test pins.
Objective: To determine the optimal contrast injection protocol for 64-MDCT coronary angiography. Materials and methods: One hundred and fifty consecutive patients scheduled to undergo retrospectively electrocardiographically gated 64-MDCT. Each 30 patients were assigned to use a different contrast protocol: group 1: uniphasic protocol (contrast injection without saline flush); group 2: biphasic protocol (contrast injection with saline flush); group 3A, 3B and 3C: triphasic protocol (contrast media + different saline diluted contrast media + saline flush). Image quality scores and artifacts were compared and evaluated on both transaxial and three-dimensional coronary artery images among each contrast protocol. Results: Among the triphasic protocol groups, group 3A (30%:70% contrast media-saline mixture was used in second phase) used the least contrast media and had the least frequency of streak artifacts, but there were no significant ...
The development of chromatin immunoprecipitation methods coupled with DNA microarray (ChIP-chip) technology has enabled genome-wide identification of cis-DNA regulatory elements to which transcription...Full Text Available
In this study we have profiled the free sterol content of cerebrospinal fluid by a combination of charge tagging and liquid chromatography-tandem mass spectrometry. Surprisingly, the most abundant cholesterol...Full Text Available
Numerous xenobiotics, including therapeutics agents, are substrates for bioactivation to electrophilic reactive intermediates that may covalently modify biomolecules. Selective estrogen receptor...Full Text Available
To study the effect of agonist on the TRH (thyrotrophin-releasing hormone) receptor protein, an epitope-tagged receptor was stably expressed in HEK-293 cells (human embryonic kidney 293 cells) and receptor...Full Text Available
BackgroundGenotyping analysis using capillary DNA sequencing with fluorescently labeled primer pairs obtained by polymerase chain reaction (PCR) is widely used, but is expensive....Full Text Available
Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to ...
The lipid fractions of residues from historical pharmaceutical ointments were analysed by reversed-phase liquid chromatography coupled with atmospheric pressure chemical ionization and mass spectrometer detection. The residues were contained in a series of historical apothecary jars, dating from the eighteenth century and conserved at the "Aboca Museum" in Sansepolcro (Arezzo, Italy) and at the pharmacy of the "Real Cartuja de Valldemossa" in Palma de Majorca (Spain). The analytical protocol was set up using a comparative study based on the evaluation of triacylglycerol (TAG) compositions in raw natural lipid materials and in laboratory-reproduced ointments. These ointments were prepared following pharmaceutical recipes reported in historical treatises and used as reference materials. The reference materials were also subjected to stress treatments in order to evaluate the modification occurring in the TAG profiles as an effect of ageing. ...
Within the cardiac cell, the movements of calcium ions are tightly regulated by a number of regulatory proteins including pumps, and channels. The sarcoplasmic reticulum (SR) is in large part...Full Text Available
Opinion statement Because a minority of patients with D-transposition of the great arteries are diagnosed in utero by ultrasound, most present after delivery with cyanosis. In the absence of apparent lung disease, cyanotic neonates suspected of having a cardiac lesion should be immediately transferred to an intensive care unit at a pediatric tertiary care center for monitoring, resuscitation, and to define the cardiac anatomy and physiology. A prostaglandin E-1 infusion is usually initiated to maintain ductal patency and promote intra-cardiac mixing. In the past, balloon atrial septostomy (BAS) was routinely performed to enlarge the atrial septal defect and improve intra-cardiac mixing while the infants awaited surgery. Recent literature has reported an increase risk of stroke in neonates ...
Congestive heart failure (CHF) is a leading cause of morbidity and mortality. CHF is marked by atrial and ventricular enlargement and reduced cardiac contractility, as well as an association...Full Text Available
In response to changes in workload, the heart grows or shrinks. Indeed, the myocardium is capable of robust and rapid structural remodeling. In the setting of normal, physiological demand, the...Full Text Available
Cardiac Malposition refers to any position of the heart other than a left-sided heart in a situs solitus individual. Associated cardiac malformations are so complex that even angiocardiographic and autopsy studies may not afford an accurate information. Although the terms and classifications used to describe the internal cardiac anatomy and their arterial connections in cardiac malpositions differ and tend to be confusing, common agreement exists on the need for a segmental approach to diagnosis. Authors present 18 cases of cardiac malpositions in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between 1971 and 1979. Authors analyzed the clinical, radiographic, operative and autopsy findings with the emphasis on the angiocardiographic findings. The results are as follows: 1. Among ...
Calgary-based TAG Oil is an exploration company that manages 4.1 million acres of major producing oil and gas fields in New Zealand. The enormous Maui field, with 4 tcf of natural gas in place, has dominated the gas market in New Zealand by meeting nearly 90 per cent of the country's energy demand at costs much lower than world prices. However, the maturing field is in decline and will cease production by 2008. New gas field discoveries will only meet 60 per cent of the country's energy requirements for 5 additional years. Unless new large reserves of gas are discovered, the supply and demand situation will get worse. Lead time to place new production on-stream requires 5 to 10 years, which creates a large supply gap over the next decade. Public resistance to coal-fired power plants, new hydroelectric dams and nuclear power has left the country with no viable alternative to natural gas. TAG Oil has taken this unique opportunity to create value ...
The use of platinum(II) complexes as tags and probes for biomolecules is indeed advantageous for their reactivities can be selective for certain purposes through an interplay of mild reaction conditions and of the ligands bound to the platinum. The use of {sup 195}Pt NMR as a method of detecting platinum and its interactions with biomolecules was carried out with the simplest model of platinum(II) tagging to proteins. Variable-temperature {sup 195}Pt NMR spectroscopy proved useful in studying the stereodynamics of complex thioethers like methionine. The complex, Pt(trpy)Cl{sup +}, with its chromophore has a greater potential for probing proteins. It is a noninvasive and selective tag for histidine and cysteine residues on the surface of cytochrome c at pH 5. The protein derivatives obtained are separable, and the tags are easily quantitated and differentiated through the metal-to-ligand charge transfer ...
Increased oxidative stress is a known cause of cardiac dysfunction in animals and patients with diabetes, but the sources of reactive oxygen species [e.g., superoxide anion (O2−)]...Full Text Available
Cardiac tumours may display diverse symptoms through potential involvement of any structure of the heart. We describe a case of a highly malignant thymoma with involvement of different cardiac structures with important haemodynamic compromise. With the high sensitivity of transthoracic echocardiography for detection of intracardiac masses, computed tomography and magnetic resonance add essential structural preoperative information on the tumour and surrounding tissue as vessels, pleura, lung and mediastinum.
The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).
Recent literature indicates that torsion of the left ventricle (LV) is a promising predictor for response to cardiac resynchronisation therapy (CRT). Among patients with severe heart failure, 45 to 75% of patients show rigid body rotation, where the base and apex rotate in the same direction, instead of normal, opposite rotation. The occurrence of this phenomenon seems to be a good indicator for response to CRT. From this review, it can be concluded that LV torsion might be a welcome addition to current selection criteria.
1 Measurements of the binding of 12-alpha-[3H]-digoxin to the membranes of intact erythrocytes, erythrocytic 86rubidium uptake and intraerythrocytic sodium concentrations have been made in the red cells...Full Text Available
Purpose: An animal model is used to investigate whether MR angiography combined with super-paramagnetic particles of iron oxide (SPIO) is suitable for detecting thromboses. Methods: 42 rats in groups of 7 each were examined on days 1, 3, 5, 7, 9 and 11, respectively, after mechanical/chemical thrombus induction in a 1.5 Tesla magnet with a FISP sequence (TR/TE/FA 50 ms/6 ms/40 ). Imaging was performed before and up to 90 minutes after intravenous injection of 30 {mu}mol FE/kg BW of the experimental SPIO (hydrodynamic diameter, 34{+-}17 nm LLS; R1 and R2 relaxivity at 0.47 T, 31 and 57 L/(mmol*s)). MIP reconstructions of MR angiographies were submitted to consensus assessment by two examiners using histology as the gold standard. Results: The image quality of MIP reconstructions was rated as good in 38 of 42 cases. With regard to thrombotic vessel occlusion, MR angiography coincided with histology in 17 of 42 cases and differed in 25, lumen ...
Many social Web sites allow users to publish content and annotate with descriptive metadata. In addition to flat tags, some social Web sites have recently began to allow users to organize their content and metadata hierarchically. The social photosharing site Flickr, for example, allows users to group related photos in sets, and related sets in collections. The social bookmarking site Del.icio.us similarly lets users group related tags into bundles. Although the sites themselves don't impose any constraints on how these hierarchies are used, individuals generally use them to capture relationships between concepts, most commonly the broader/narrower relations. Collective annotation of content with hierarchical relations may lead to an emergent classification system, called a folksonomy. While some researchers have explored using tags as evidence for learning folksonomies, we believe that hierarchical relations described ...
Relationship between hemodynamic response to exercise and distribution of pulmonary perfusion was studied in 71 patients with mitral stenosis. Distribution was estimated by using computerized Tc-99m-MAA perfusion images (digital perfusion images; DPI). DPI were composed of isocount areas. Various types of DPI were obtained and were classified to 6 grades (G) according to patterns of 100 - 70% isocount area in right anterior DPI, i.e. G-0 (normal), G-1 (increase of perfusion at upper zone), G-2 (uniform distribution), G-3 (disappearance of basal hyperperfusion area), G-4 (apical hyperperfusion area) and G-5 (decrease of perfusion at lower zone). Patients were devided to 4 groups according to grade. At rest there were no marked hemodynamic differences between groups (n = 71, mean pulmonary artery pressure (mPA); 24.8 +- 11.0 mmHg, cardiac index (CI); 2.7 +- 0.81 lmM/sup 2/), however hemodynamic parameter during exercise ...
The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at baseline CT and had low ...
Encapsulation of a unique isotopic blend of krypton and xenon gas employs a special application of laser technology. The encapsulated gas is then used as the primary medium for detection and identification of failed nuclear fuel rods. The use of gas tagging as a means of detecting and identifying failed nuclear fuel rods has been successfully demonstrated and used by the Argonne National Laboratory, Experimental Breeder Reactor (EBR-2) Project, and the Westinghouse Hanford Company (WHC), Fast Flux Test Facility (FFTF) Fast Breeder Reactor Program. The Power Reactor and Nuclear Fuel Development Corporation (PNC) of Japan has selected this leak detection system for use in their MONJU Prototype Reactor fuel assemblies. The MONJU reactor is almost identical in design to the highly successful FFTF reactor, which is currently in standby status.
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)
Cardiac contractile function is dependent on the integrity and function of the sarcolemmal membrane. Swimming exercise training is known to increase cardiac contractile performance. The purpose of the present study was to examine whether a swimming exercise program would alter sarcolemmal enzyme activity, ion flux, and composition in rat hearts. After approximately 11 wk of exercise training, cardiac myosin and actomyosin Ca2+-adenosinetriphosphatase (ATPase) activity was significantly higher in exercised rat hearts than in sedentary control rat hearts. Glycogen content was increased in plantaris and gastrocnemius muscles from exercised animals as was succinic dehydrogenase activity in gastrocnemius muscle of exercised rats in comparison to sedentary rat preparations. Sarcolemmal vesicles were isolated from hearts of exercise-trained and control rats. Sarcolemmal Na+-K+-ATPase and K+-p-nitrophenylphosphatase activities, ...
Purpose: Cardiomyopathy is one of the major complications of {beta} thalassaemia major as a result of transfusion iron overload. The aim of our study is to evaluate with MR if there is any difference of iron deposition signal intensity (SI) or distribution between non-cardiopatic and cardiopatic thalassaemic patients in order to establish if there is a relationship between cardiopathy and iron deposition. Materials and methods: We studied 20 patients affected by {beta} thalassaemia major, of whom 10 cardiopatic and 10 non-cardiopatic, and 10 healthy volunteers as control group. Serum ferritin and left ventricular ejection fraction were calculated in thalassaemic patients. All patients were examinated using a 1.5 MR unit with ECG-gated GE cine-MR T2*-weighted, SE T1-weighted and GE T2*-weighted sequences. In all cases, using an adequate ROI, the myocardial and skeletal muscle signal intensity (SI), the myocardial/skeletal muscle signal intensity radio (SIR) and the SI average of the ...
Lobar emphysema is an uncommon cause of respiratory distress in infancy. Congenital heart disease is seen in about 20% of the patients with infantile (congenital) lobar emphysema. We described six infants with lobar emphysema. In three of them a congenital heart disease was demonstrated by cardiac catheterization and cineangiography; two had a tetralogy of Fallot with right aortic arch and the third infant a ventricular septal defect. The pulmonary angiography showed stretching of the arteries with very poor filling of the peripheral arteries and a characteristic smaller pulmonary vein in the affected lobe. In all the six patients the pulmonary artery pressure was normal. All the patients underwent lobectomy with good results. We feel that a preoperative cardiac catheterization and cineangiography is of value in this very sick group of infants. (orig.).
Aims and objectives.- To investigate infant well-being as measured by feeding and sleeping and parental support following discharge from the NICU in infants following major cardiac surgery. Background.- Infant feeding and sleeping have been identified as two of the most important concerns reported by parents. These concerns have been reported anecdotally for infants who have undergone cardiac surgery in the neonatal period. Design.- A prospective study using questionnaires and phone interviews followed a cohort of parents of neonates who underwent surgery in the neonatal period for congenital heart disease. Methods.- The study was conducted using validated questionnaires and phone interviews with a semi-structured questionnaire. The questionnaires were administered prior to discharge from ...
Certain fluorocarbons, such as difluorodichloromethane (FC 12), depress the cardiovascular system by diminution of all the transmembrane ionic conductances in cardiac tissues. Does FC 12 also inhibit active transport and thus enzymatic activity and cellular energy. We measured phosphocreatine (PC), adenosine triphosphate (ATP) and cyclic adenosine monophosphate (AMPc) in rat hearts. Rats were randomly divided into 4 groups; 2 control groups: one breathing a mixture of oxygen (21%) and nitrogen (79%) (group C) and the other breathing the same mixture but simultaneously perfused with 1 microgram/kg/min. epinephrine (groupe E-C); 2 trial groups T and E-T where nitrogen was replaced by FC 12. The maximal FC 12 concentration of 720 micrograms/ml in arterial blood produced no significant difference in the concentrations of these three metabolites compared with controls.
Abstract Sudden infant death syndrome (SIDS) is always a devastating and unexpected occurrence. SIDS is the leading cause of death in the first 6 months after birth in the industrialized world. Since the discovery in 1998 of long QT syndrome as an underlying substrate for SIDS, around 10-20% of SIDS cases have been proposed as being caused by genetic variants in either ion channel or ion channel-associated proteins. Until now, 10 cardiac channelopathy susceptibility genes have been found to be implicated in the pathogenesis of SIDS. Four of the genes encode cardiac ion channel a-subunits, 3 genes encode ion channel b-subunits, and 3 genes encode other channel-interacting proteins. All 10 genes have been associated with primary electrical heart diseases. SIDS may hereby be the initial sympt...
... It has 2x 15L bins: one for food waste, the other for recycling, which slide out on ball bearing steel runners. Both have plastic inner buckets that can be lifted out. Supplied with fixing brackets. To fit 30cm-wide cabinets Filed Under: Top Products Tagged With: bedroom, bins, drawers, drawersshelveskitchenbins, garden, home, homegardenbedroomstorage, John Lewis, kitchen, shelves, storage ...
In 1996, the National Marine Fisheries Service and the University of Washington completed the fourth year of a multi-year study to estimate survival of juvenile salmonids (Oncorhynchus spp.) passing through dams and reservoirs on the Snake River. Actively migrating smolts were collected near the head of Lower Granite Reservoir and at Lower Granite Dam, tagged with passive integrated transponder (PIT) tags, and released to continue their downstream migration. Individual smolts were subsequently detected at PIT-tag detection facilities at Lower Granite, Little Goose, Lower Monumental, McNary, John Day and Bonneville Dams. Survival estimates were calculated using the Single-Release (SR) and Paired-Release (PR) Models. Timing of releases of tagged hatchery steelhead (O. mykiss) from the head of Lower Granite Reservoir and yearling chinook salmon (O. tshawytscha) from Lower Granite Dam in 1996 spanned the ...
BackgroundPlasmid encoded blaCTX-M enzymes represent an important sub-group of class A β-lactamases causing the ESBL phenotype which is increasingly...Full Text Available
The side effects of cancer therapy on normal tissues limit the success of therapy. Generation of reactive oxygen species (ROS) has been implicated for numerous chemotherapeutic agents including doxorubicin...Full Text Available
ObjectivesThe aim of this study was to assess the diagnostic and prognostic value of heart-type fatty acid-binding protein (H-FABP) in elective percutaneous coronary intervention...Full Text Available
The metal parts of cardiac valve prostheses cause reactions in the surrounding tissues of the heart. In some dogs rather abnormal reactions were found, and were attributed to corrosion of the stainless...Full Text Available
BackgroundMedian sternotomy infection and bony nonunion are two commonly described complications which occur in 0.4 - 5.1% of cardiac procedures. Although relatively infrequent,...Full Text Available
Radionuclide angiocardiography provides a noninvasive assessment of cardiac function and blood flow through the heart and lungs. During the past three years, this procedure has been used at the Duke...Full Text Available
ObjectivesPericardial tamponade after cardiac surgery is difficult to diagnose, thereby rendering timing of rethoracotomy hard. We aimed at identifying factors predicting the outcome...Full Text Available
ObjectiveTo evaluate the association of physical activity with left ventricular structure and function in the general population in a community setting.Full Text Available
We present a case of cardiac tamponade following umbilical venous catheterization in a neonate, an uncommon, yet potentially fatal complication. Timely diagnosis by echocardiography and urgent pericardiocentesis proved lifesaving. PMID:21654008
Although the heart rapidly adapts cardiac output to match the body’s circulatory demands, the regulatory mechanisms ensuring that sufficient ATP is available to perform the required...Full Text Available
To determine the mechanism of the cardiac dilatation and reduced contractility of obese Zucker Diabetic Fatty rats, myocardial triacylglycerol (TG) was assayed chemically and morphologically. TG was...Full Text Available
... of the American Medical Association JAMA PATIENT PAGE Cardiopulmonary Resuscitation W hen the heart stops beating (cardiac arrest), ... circulation (blood flow) returns or is restored. Providing cardiopulmonary resuscitation ( CPR ) is a way to keep some circulation ...
The thiadiazinon derivative EMD 57033 has been found previously in cardiac muscle to increase isometric force generation without a proportional increase in fiber ATPase, thus causing a reduction in...Full Text Available
OBJECTIVE--To develop, test, and validate an algorithm for diagnosing disease in neonates during an over the telephone referral to a specialist cardiac centre. DESIGN--A draft algorithm requiring only...Full Text Available
BackgroundAtrial fibrillation (AF) is the most common cardiac arrhythmia with a population prevalence of about 1%. Natriuretic peptide level is elevated in patients with AF with...Full Text Available
Background With the increasing use of cineless diagnostic angiography laboratories, modern telecommunication networks provide an excellent opportunity to transfer dynamic cardiac...Full Text Available
We report a case of chylopericardium after ascending aorta and aortic valve replacement, which presented as late tamponade. We discuss the various treatment options in this rare condition which can...Full Text Available
We report a case of a female patient who was operated at the third relapse of an atrial myxoma caused by Carney complex. The difficult operation was performed without any complications despite extensive...Full Text Available
Catheter ablation is a first line treatment for many cardiac arrhythmias and is generally performed under x-ray fluoroscopy guidance. However, current techniques for ablating complex arrhythmias such...Full Text Available
Zipper-interacting protein kinase (ZIPK) is a member of the death-associated protein kinase family associated with apoptosis in nonmuscle cells where it phosphorylates myosin regulatory light chain...Full Text Available
AimsA better understanding of the ionic mechanisms for cardiac automaticity can lead to better strategies for engineering bio-artificial pacemakers. Here, we attempted to better...Full Text Available
Two cases of left ventricular aneurysm, a 16-year-old black boy and a 23-year-old white girl, from Bahia, Brazil, are presented. In both patients there was enlargement of the cardiac silhouette and...Full Text Available
A case of severe intractable angina pectoris with normal angiography is presented. Following video assisted thoracic sympathectomy the patient died of heart failure. Microvascular cardiac amyloidosis...Full Text Available
An integrated system of micro-and mini-computers is described to acquire, analyze, store and report data on the total activity of the heart of a critically ill patient. Real-time beat and rhythm diagnoses...Full Text Available
Recent rapid growth in mobile computing technologies enables telemedicine applications to operate on mobile devices. Our focus is on the design of an integrated electrocardiogram (ECG) beat detector on a Personal Digital Assistant (PDA) platform for the health screening process. The ECG beat detector module will be supported by the PDA version of Personal Health Information Management System (PHIMS) and Facilitated Accurate Referral Management System (FARMS) through wireless network infrastructure as a home-based mobile cardiac monitoring solution. PMID:17282192
BACKGROUND AND AIM OF THE STUDY: Abnormal flow conditions across aortic bioprosthetic valves may result in degenerative processes. Thus, it is important to implant biological valve prostheses with velocity profiles similar to those of native valves. The study aim was to compare blood velocity and velocity gradient profiles downstream of stented and stentless aortic valves implanted in pigs, and in native porcine valves. METHODS: Stented valve prostheses (Mitroflow, n = 7) or stentless valve prostheses (Solo, n = 5 or Toronto SPV, n = 7) were implanted into pigs; the native valve was retained in eight animals. After weaning the animals from cardiopulmonary bypass, cardiac magnetic resonance imaging was performed to determine the blood velocities and velocity gradient profiles. RESULTS: The native valves had a significantly lower peakvelocity (92 +/- 26 cm/s) than the artificial valves (Solo: 247 +/- 107 cm/s; Toronto: 252 +/- 41 cm/s; Mitroflow: ...
... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...
We present a measurement of the t{bar t} production cross section using events with one charged lepton and jets from p{bar p} collisions at a center-of-mass energy of 1.96TeV. In these events, heavy flavor quarks from top quark decay are identified with a secondary vertex tagging algorithm. From 162 pb{sup -1} of data collected by the Collider Detector at Fermilab, a total of 48 candidate events are selected, where 13.5 {+-} 1.8 events are expected from background contributions. We measure a t{bar t} production cross section of 5.6{sub -1.1}{sup _1.2}(stat.){sub -0.6}{sup +0.9}(syst.)pb.
The LHCb experiment that is being settled in CERN is dedicated to the study of CP violation and rare decays in the field of beauty hadrons. The phenomenological background necessary to an adequate understanding of the physics of flavor is presented in the first chapter, it is shown how the flavordynamics can open the way to new physics. The second chapter is dedicated to a brief presentation of the LHCb detector. Two aspects of the design of the muon trigger are more detailed: the radiation resistance of the opto-electronic transmitters and the simulated performances of the trigger. The third chapter reviews the tasks linked to the tagging of the savors of B mesons which will be an important step in all the experiments made at LHCb. The recent progress in heavy savor physics as well as the expected contribution of LHCb in this field are presented in the fourth chapter, especially the search for new physics in penguin diagrams b {yields} s.
Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available
We have studied the signals for a heavy Higgs boson in the processes {gamma}{gamma}{yields}WWWW, and {gamma}{gamma}{yields}WWZZ at a photon linear collider. The results are based on the first complete tree-level calculation for these reactions. We show that, with a forward ``spectator`` W tag, and a central ``spectator`` W veto to suppress backgrounds from transverse W, Z production, the invariant mass spectrum of central WW, ZZ pairs is sensitive to Higgs bosons with a mass up to 1 TeV in a 2-TeV linear collider. ((orig.)).
...Oster | Best sexual wellness info Best sexual wellness info Home Posts Tagged Oster Oster Professional 103 Stim-U-Lax Massager Reviews Made of 100% ball bearing construction Traditional frame design with special frame contour to fit hand and reduce hand fatigue Chrome housing and rubber hand pad Heavy-duty, single speed UL approved 120v This lightweight therapeutic massager combines the advantages of hand and mechanical massage. Its special contoured design reduces hand fatigue and its universal ...
We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future {gamma}{gamma} colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future {gamma}{gamma} collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).
We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future #gamma##gamma# colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future #gamma##gamma# collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).
Continuum events represent an eminent source of background in any e+e- experiment. As these have a higher branching ratio than BB-bar events (at BaBar this ratio is estimated to about 3.5) or ?+?- events, efficient continuum background suppression is essential in many analyses. Using Artificial Neural Networks and the Nearest Neighbor Method we developed several selectors which, based only on the global event shape variables, efficiently tag BB-bar events and ?+?- events against the continuum background. These selectors could then be combined with the channel specific information in various types of analyses. The study was done using a parametric Monte Carlo.
Systemic and splanchnic hemodynamics of the chronic bile duct-ligated rat were characterized by radioactive microspheres. Conscious and pentobarbital sodium-anesthetized, bile duct-ligated and sham-operated rats had cardiac output and regional organ blood flows determined. The conscious bile duct-ligated rat compared with the sham-operated showed a hyperdynamic circulation with an increased cardiac output and portal tributary blood flow. Pentobarbital sodium anesthesia induced marked hemodynamic changes in both sham-operated and bile duct-ligated rats. The latter group was especially sensitive to its effects; thus, comparison of cardiac output and portal tributary blood flow between anesthetized bile duct-ligated and sham-operated rats showed no significant differences. The authors conclude that the rat with cirrhosis due to chronic bile duct ligation is an excellent model for hemodynamic investigations but should be ...
Exercise training associated with robust conditioning can be useful for the study of molecular mechanisms underlying exercise-induced cardiac hypertrophy. A swimming apparatus is described to control training regimens in terms of duration, load, and frequency of exercise. Mice were submitted to 60- vs 90-min session/day, once vs twice a day, with 2 or 4% of the weight of the mouse or no workload attached to the tail, for 4 vs 6 weeks of exercise training. Blood pressure was unchanged in all groups while resting heart rate decreased in the trained groups (8-18%). Skeletal muscle citrate synthase activity, measured spectrophotometrically, increased (45-58%) only as a result of duration and frequency-controlled exercise training, indicating that endurance conditioning was obtained. In groups which received duration and endurance conditioning, cardiac weight (14-25%) and myocyte dimension (13-20%) increased. The best conditioning protocol to ...
Background When assessing the function of the cardiovascular system, cardiac output (CO) is a substantial parameter. For its determination, numerous non-invasive techniques have been proposed in the recent years including inert gas rebreathing (IGR) and impedance cardiography (ICG). The aim of our study was to evaluate whether a novel ICG algorithm (electrical velocimetry) and IGR can be used interchangeably in the clinical setting. Methods A total of 120 consecutive stable patients were included resulting in two pairs of repeated non-invasive cardiac output measurements. Results The mean CO was 5.0???1.2?l/min (range 2.6?8.6?l/min) using IGR and 4.4???1.1?l/min (1.7?7.4?l/min) using ICG, respectively. Bland?Altman analysis revealed an acceptable agreement with a mean bias of 0.6???1.2?l/m...
The specific research goal of this project is to identify means to restore and rebuild the Snake River white sturgeon (Acipenser transmontanus) population to support a sustainable annual subsistence harvest equivalent to 5 kg/ha/yr (CBFWA 1997). Based on data collected, a white sturgeon adaptive management plan will be developed. This 2001 annual report covers the fifth year of sampling of this multi-year study. In 2001 white sturgeon were captured, marked, and population data were collected in the Snake and Salmon rivers. The Snake River was sampled between Lower Granite Dam (rkm 174) and the mouth of the Salmon River (rkm 303), and the Salmon River was sampled from its mouth upstream to Hammer Creek (rkm 84). A total of 45,907 hours of setline effort and 186 hours of hook-and-line effort was employed in 2001. A total of 390 white sturgeon were captured and tagged in the Snake River and 12 in the Salmon River. Since 1997, 36.1 percent of the ...
Ventricular septal defects can occur as part of other congenital cardiac malformations or as an isolated finding. Aneurysms of the sinus of Valsalva are rare, most commonly involving the right or noncoronary sinuses. They can be congenital or acquired through infection, trauma, or degenerative diseases. They frequently co-exist with ventricular septal defects, aortic valve dysfunction, or other cardiac abnormalities. More commonly, sinus of Valsalva aneurysms are diagnosed after the clinical sequelae of rupture. Several etiologic factors may lead to the development of pathologic pericardial effusion and the detection of pericardial effusion was one of the first applications of echocardiography to gain widespread acceptance. We present a case of a chance finding of an aneurysm of the right ...
Hsp20, referred to as HspB6, is constitutively expressed in various tissues. Specifically, HspB6 is most highly expressed in different types of muscle including vascular, airway, colonic, bladder, and uterine smooth muscle; cardiac muscle; and skeletal muscle. It can be phosphorylated at Ser-16 by both cAMP- and cGMP-dependent protein kinases (PKA/PKG). Recently, Hsp20 and its phosphorylation have been implicated in multiple physiological and pathophysiological processes including smooth muscle relaxation, platelet aggregation, exercise training, myocardial infarction, atherosclerosis, insulin resistance and Alzheimer's disease. In the heart, key advances have been made in elucidating the significance of Hsp20 in contractile function and cardioprotection over the last decade. This mini-rev...
Introduction: Patients in underdeveloped nations have limited access to life-saving medical technology including cardiac rhythm management (CRM) devices. We evaluated alternative means to provide such technology to this patient population while assessing the safety and efficacy of such a practice. Methods: Patients in the United States with clinical indications for extraction of CRM devices were consented. Antemortem CRM devices were cleaned and sterilized following a protocol established at our institution. Surveillance in vitro cultures were performed for quality assurance. The functional status of pulse generators was tested with a pacing system analyzer to confirm at least 70% battery life. Most generators were transported, in person, to an implanting institution in Nicaragua. Recipien...
The aims of this study were to identify risk factors and evaluate the association with clinical outcomes of postoperative cardiac surgery-associated acute kidney injury (CSA-AKI). Data from 2488 consecutive adult patients were analyzed. Patients were classified as having CSA-AKI based on the risk, injury, failure, loss of kidney function, and end-stage kidney disease (RIFLE) criteria using peak postoperative creatinine in the postoperative intensive care unit (ICU). Multiple stepwise logistic regression analysis was used to identify independent risk factors for CSA-AKI. CSA-AKI occurred in 584 patients (23.5%). CSA-AKI patients had significantly longer aortic cross-clamp and cardiopulmonary bypass times. Furthermore, CSA-AKI patients had higher hospital mortality (5.5% vs 1.5%, PCopyright2...
As a result of nuclear power plant accidents, large areas receive radioactive inputs of Cs-137. This cesium accumulates in herbs growing in such territories. The problem is whether the herbs contaminated by radiocesium may be used as a raw material for medicine. The answer depends on the amount of Cs-137 transfered from the contaminated raw material to the medicine. We have presented new results of the transfer of Cs-137 from contaminated Digitalis grandiflora Mill. and Convallaria majalis L. to medicine. We found that the extraction of Cs-137 depends strongly on the hydrophilicity of the solvent. For example 96.5%(vol.) ethyl alcohol extracts less Cs-137 (11.6%) than 40%(vol.) ethyl alcohol or pure water (66.2%). The solubility of the cardiac glycosides is inverse to the solubility of cesium, which may be of use in the technological processes for manufacturing ecologically pure herbal medicine.
Breath analysis could offer a non-invasive means of intravenous drug monitoring if robust correlations between drug concentrations in breath and blood can be established. In this study, propofol blood and breath concentrations were determined in an animal model under varying physiological conditions. Propofol concentrations in breath were determined by means of two independently calibrated analytical methods: continuous, real-time proton transfer reaction mass spectrometry (PTR-MS) and discontinuous solid-phase micro-extraction coupled with gas chromatography mass spectrometry (SPME-GC-MS). Blood concentrations were determined by means of SPME-GC-MS. Effects of changes in pulmonary blood flow resulting in a decreased cardiac output (CO) and effects of dobutamine administration resulting in...
It is uncertain if downregulation of ?-adrenoceptor signaling pathway is promoted by an enhanced adrenergic tone at an early stage of cardiac disease, or it develops secondary to detrimental local myocardial changes in advanced heart failure. We examined the integrity of ?-adrenoceptor signaling pathway upon chronic infusion of isoproterenol, a ?-adrenoceptor agonist, at a dose producing no structural left ventricular (LV) remodeling and systolic dysfunction. Subcutaneous isoproterenol infusion (400??g?kg?1?h?1 over 16?days) to guinea pigs using osmotic minipumps produced no change in cardiac weights, LV internal dimensions, myocyte cross-sectional area, extent of interstitial fibrosis, and basal contractile function. Isolated, perfused heart preparations from isoproterenol-treated guinea ...
One of the goals of the DARPA Virtual Soldier Project is to aid the field medic in the triage of a casualty. In Phase I, we are currently collecting 12 baseline experimental physiological variables and a cardiac gated Computed Tomography (CT) imagery for use in an prototyping a futuristic electronic medical record, the "Holomer". We are using physiological models and Kalman filtering to aid in diagnosis and predict outcomes in relation to cardiac injury. The physiological modeling introduces another few hundred variables. Reducing the complexity of the above into easy-to-read text to aid in the triage by the field medic is the challenge with multiple display solutions. A description of the possible techniques follows. PMID:15718701
In 9 over 12 patients who underwent cardiac transplantation computed tomography was performed. In 5 of them CT was obtained also before the surgical treatment. In all patients angio-CT technique was performed, while the ECG-gated technique was employed only before surgery. CT shows changes in morphology of both atria but over all of the right one, and rotation of the heart on the longitudinal axis. The conditions of the pericardium are particulary well demonstrated: in 5 cases pericardial effusion was observed, 3 times localized and 2 times diffuse. Only in 1 patient a small thrombus in the right atrium was demonstrated. CT allows the possibility to obtain simultaneously information on mediastinum, lung and pleura. Pleural effusion, pulmonary infections and mediastinal complications are easily demonstrated.
The first cardiac pacemaker implants occurred in the late 1950s and involved insertion of epicardial or epimyocardial leads and abdominal pulse generators. By the mid 1960s, cardiologists were making attempts to insert transvenous leads into the right ventricle. These early unipolar leads had large, polished, high polarization electrodes, no fixation device, and no lumen in which to place a stylet for lead positioning. The lead implantation procedures were usually long and the irradiation to both patient and operator excessive. Pulse generators were powered by zinc-mercury cells, which were large, unreliable, and prone to sudden output failure. Postoperative complications such as lead dislodgement, exit block, and premature power source failure were very common with most patients requiring...
Fatalities resulted from aluminium phosphide (ALP) intoxication in completely healthy children with no preceded clinical sings or symptoms were presented. Data regarding circumstances, autopsy reports, histopathological examination, toxicological investigation, and police enquiries were also collected and evaluated. The affected children were females, and 6-16 years old. They were completely healthy and died suddenly in relation to some physical activities such as running, walking, and bathing, without any prior complain. The viscera showed intense congestion with moderate to severe pulmonary edema. The cause of the sudden termination of life in the reported cases is mostly cardiac ones. Physical exertion may precipitate death due to increased cardiac stress, increased oxygen demand, and b...
This paper presents a patient specific deformable heart model that involves the known electrical and mechanical properties of the cardiac cells and tissue. The whole heart model comprises ten Tusscher's ventricular and Nygren's atrial cell models, the anatomical and electrophysiological model descriptions of the atria (introduced by Harrild et al.) and ventricle (given by Winslow et al.), and the mechanical model of the periodical cardiac contraction and resting phenomena proposed by Moireau et al. During the propagation of the depolarization wave, the kinetic, compositional and rotational anisotropy is handled by the tissue, organ and torso model. The applied patient specific parameters were determined by an evolutionary computation method. An intensive parameter reduction was performed u...
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available
performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...
This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)
We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available
In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available
This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available
Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.
The clinical manifestation of wounds of the heart is determined by the mode, site and size of the injury as well as the structure of the pericardial and myocardial lesion. Diagnosis can be confirmed by ECG and echocardiography. Only 20% of the patients with penetrating wounds of the heart live for more than 30 minutes. Pericardio-centesis should be used only to gain time for a safe sternotomy, cardiac decompression and suture of the wound of the heart. An aggressive surgical approach is mandatory. Cardiopulmonary bypass is necessary only to correct of concomitant lesions. PMID:1983618
Background and ObjectivesClopidogrel resistance or low-responsiveness may be associated with recurrent atherothrombotic events after drug-eluting stent (DES) implantation. We prospectively...Full Text Available
In this paper the main design requirements concerning the setting up of a telemetry ECG monitoring system are presented. The design's most important technical solutions as well as some details are also discussed. This system is intended to provide skilled medical assistance during the cardiac rehabilitation of both asymptomatic and high risk coronary patients
1. We studied the effects of flash photolysis on the novel enantiomeric cardiac inotropes EMD 57033 (a calcium sensitizer) and EMD 57439 (a phosphodiesterase III inhibitor) in rat isolated ventricular...Full Text Available
Phospholamban (PLB) is a 52-amino acid integral membrane protein that helps to regulate the flow of Ca2+ ions in cardiac muscle cells. Recent structural studies on the PLB pentamer...Full Text Available
A 56-year-old man admitted to our hospital for cardiac tamponade due to dilated cardiomyopathy did not respond to treatment by usual medical means or surgery. Pericardio-peritoneal drainage was conducted using a subcostal approach. Seven months later, the patient remains well and free of signs of pericardial tamponade. This method has proved to be safe and effective in patients with persistent massive pericardial effusion. PMID:10496067
We report a new case of Lyme disease with cardiac manifestations, which has been possible to follow during the long period of 12 years. We have detected the usual ECG abnormalities, and concentric hypertrophic myocardiopathy, by echocardiography. The acute myocarditis was demonstrated by /sup 111/In-antimyosin scintigraphy, which showed global myocardial uptake of the tracer, constituting the first report, to our knowledge, of Lyme myocarditis diagnosed by this method.
Long-term heat acclimation (AC, 30d/34°C) is a phenotypic adaptation leading to increased thermotolerance during heat stress (HS, 2 h 41°C). AC also renders protection against...Full Text Available
Mice lacking Kv1.1 Shaker-like potassium channels encoded by the Kcna1 gene exhibit severe seizures and die prematurely. The channel is widely expressed in...Full Text Available
G protein-coupled receptors (GPCRs) are known to modulate intracellular effectors involved in cardiac function. We recently reported homocysteine (Hcy)-induced ERK-phosphorylation was suppressed...Full Text Available
We report for the first time a case of a 54 years old man with a fatal motorcycle accident due to an external bleeding compression of left internal mammary artery graft to the left anterior descending...Full Text Available
The myocardial infarct induced by isoproterenol in spontaneously hypertensive rats accumulates higher activities of /sup 99/sup(m)Tc-PM tetracycline compared with the cardiac infarct in normotensive rats caused by the same method. The isoproterenol model of the myocardial necrosis was induced in intact rats without opening the thorax and is a convenient method for experimental radioisotope studies.
The corrected transposition of the great arteries is an usual congenital cardiac malformation, which consists of transposition of great arteries and ventricular inversion, and which is caused by abnormal development of conotruncus and ventricular looping. High frequency of associated cardiac malformations makes it difficult to get accurate morphologic diagnosis. A total of 18 cases of corrected transposition of the great arteries is presented, in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between September 1976 and June 1981. The clinical, radiographic, and operative findings with the emphasis on the angiocardiographic findings were analyzed. The results are as follows: 1. Among 18 cases, 13 cases have normal cardiac position, 2 cases have dextrocardia with situs solitus, 2 cases have dextrocardia with situs inversus ...
Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)
BackgroundOmega-3 fatty acid (n-3 FA) blood levels and intakes have been inversely associated with risk for sudden cardiac death, but their relationship with all-cause...Full Text Available
A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.
Since chlordecone (Kepone, CD) interferes with cardiac Na{sup +} ion translocases, we have studied CD effects on cardiac SR calcium pump activity. SR was isolated from heart ventricles of male Sprague-Dawley rats. Cardiac SR Ca{sup 2+}-ATPase, {sup 45}Ca-uptake and cAMP as well as calmodulin (CaM) dependent protein phosphorylation were measured. Ca{sup 2+}-ATPase was differentiated into low affinity and high affinity forms by measuring the activity using 50 and 0.7 {mu}M free Ca{sup 2+} respectively. CD in vitro inhibited {sup 45}Ca-uptake by SR in a concentration dependent manner with an IC50 value of 7 {mu}M and SR {sup 45}Ca-uptake was totally inhibited at 20-30 {mu}M CD. In agreement with this, both high affinity and low affinity Ca{sup 2+}-ATPases, which are involved in Ca{sup 2+} transport across membranes, were also inhibited by CD in a concentration dependent manner with IC50 values of 0.7 and 3.2 {mu}M ...
IntroductionBreast cancer is the most diagnosed and second leading cause of cancer deaths in the U.S. female population. An estimated 5 to 10 percent of all breast cancers are inherited, caused by mutations in the breast cancer susceptibility genes (BRCA1/2). As many as 90% of all mutations are nonsense mutations, causing a truncated polypeptide product. A popular and low cost method of mutation detection has been the protein truncation test (PTT), where target regions of BRCA1/2 are PCR amplified, transcribed/translated in a cell-free protein synthesis system and analyzed for truncated polypeptides by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and autoradiography. We previously reported a novel High Throughput Solid-Phase PTT (HTS-PTT) based on an enzyme-linked immunosorbent assay (ELISA) format that eliminates the need for radioactivity, SDS-PAGE and subjective interpretation of the results. Here, we report the next generation HTS-PTT using ...
The recent advances in RFID offer vast opportunities for research, development and innovation in agriculture. The aim of this paper is to give readers a comprehensive view of current applications and new possibilities, but also explain the limitations and challenges of this technology. RFID has been used for years in animal identification and tracking, being a common practice in many farms. Also it has been used in the food chain for traceability control. The implementation of sensors in tags, make possible to monitor the cold chain of perishable food products and the development of new applications in fields like environmental monitoring, irrigation, specialty crops and farm machinery. However, it is not all advantages. There are also challenges and limitations that should be faced in the...
Zusammenfassung Hintergrund Endograftimplantationen im oder am Aortenbogen stellen besondere Herausforderungen an die Implantationstechnik und an die mechanischen Eigenschaften von Stentgrafts und ihren Einf?hrungssystemen, bedingt durch die Notwendigkeit, die Prothesen punktgenau abzusetzen und durch die mit der Biegung im Aortenbogen zunehmende Reibungswiderst?nde innerhalb der Einf?hrungssysteme. Die Endograftsysteme der 1. Generation (Talent?, Zenith TX 1?, TAG?) zeigten in dieser Lokalisation technisch bedingte Limitationen. Neue Prothesen Bei den seit 2004 und 2005 verf?gbaren neuen Stentgrafts (E-vita?, Zenith TX 2?, Valiant?, Relay?) sind diese Limitationen weitgehend ?berwunden. Durch technische Verbesserungen von Stentgrafts und Einf?hrungssystemen ist es nun m?glich, auch lange ...
The use of indigenous bacterial root endophytes with biocontrol activity against soil-borne phytopathogens is an environmentally-friendly and ecologically-efficient action within an integrated disease management framework. The earliest steps of olive root colonization by Pseudomonas fluorescens PICF7 and Pseudomonas putida PICP2, effective biocontrol agents (BCAs) against Verticillium wilt of olive (Olea europaea L.) caused by the fungus Verticillium dahliae Kleb., are here described. A gnotobiotic study system using in vitro propagated olive plants, differential fluorescent-protein tagging of bacteria, and confocal laser scanning microscopy analysis have been successfully used to examine olive roots?Pseudomonas spp. interactions at the single-cell level. In vivo simultaneous visualization...
Summary: Protein features are often displayed along the linear sequence of amino acids that make up that protein, but in reality these features occupy a position in the folded proteins 3D space. Mapping sequence features to known or predicted protein structures is useful when trying to deduce the function of those features and when evaluating sequence or structural predictions. To facilitate this goal, we developed PDBpaint, a simple tool that displays protein sequence features gathered from bioinformatics resources on top of protein structures, which are displayed in an interactive window (using the Jmol Java viewer). PDBpaint can be used either with existing protein structures or with novel structures provided by the user. The current version of PDBpaint allows the visualization of annot...
This paper describes the Knowledge Encapsulation Framework (KEF), a suite of tools to enable knowledge inputs (relevant, domain-specific facts) to modeling and simulation projects, as well as other domains that require effective collaborative workspaces for knowledge-based task. This framework can be used to capture evidence (e.g., trusted material such as journal articles and government reports), discover new evidence (covering both trusted and social media), enable discussions surrounding domain-specific topics and provide automatically generated semantic annotations for improved corpus investigation. The current KEF implementation is presented within a wiki environment, providing a simple but powerful collaborative space for team members to review, annotate, discuss and align evidence with their modeling frameworks. The novelty in this approach lies in the combination of automatically tagged and user-vetted resources, which increases user trust in the ...
A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in combating infectious GI disorders.
The specific research goal of this project is to identify means to restore and rebuild the Snake River white sturgeon (Acipenser transmontanus) population to support a sustainable annual subsistence harvest equivalent to 5 kg/ha/yr (CBFWA 1997). Based on data collected, a white sturgeon adaptive management plan will be developed. This 2000 annual report covers the fourth year of sampling of this multi-year study. In 2000 white sturgeon were captured, marked, and population data were collected in the Snake and Salmon rivers. The Snake River was sampled between Lower Granite Dam (rkm 174) and the mouth of the Salmon River (rkm 303), and the Salmon River was sampled from its mouth upstream to Hammer Creek (rkm 84). A total of 53,277 hours of setline effort and 630 hours of hook-and-line effort was employed in 2000. A total of 538 white sturgeon were captured and tagged in the Snake River and 25 in the Salmon River. Since 1997, 32.8 percent of the ...
The specific research goal of this project is to identify means to restore and rebuild the Snake River white sturgeon (Acipenser transmontanus) population to support a sustainable annual subsistence harvest equivalent to 5 kg/ha/yr (CBFWA 1997). Based on data collected, a white sturgeon adaptive management plan will be developed. This report presents a summary of results from the 1997-2002 Phase II data collection and represents the end of phase II. From 1997 to 2001 white sturgeon were captured, marked, and population data were collected in the Snake and Salmon. A total of 1,785 white sturgeon were captured and tagged in the Snake River and 77 in the Salmon River. Since 1997, 25.8 percent of the tagged white sturgeon have been recaptured. Relative density of white sturgeon was highest in the free-flowing segment of the Snake River, with reduced densities of fish in Lower Granite Reservoir, and low densities the Salmon River. Differences were ...
The biota of the Mississippi River in an ecological recovery zone near Red Wing, MN was studied before and after start-up of a nuclear plant to acquire baseline data and to estimate changes due to thermal addition. Thermal addition produced significant decreases in primary production in a plant region during summer month periods when water temperatures were near 36C. Extensive fisheries studies and sonar tagging/tracking of S. vitreum were performed. Comparison of fisheries results with other riverine, lake, and pond studies indicated a favorable environment for the success of the fish species studied. Qualitative macroinvertebrate surveys were conducted.
Laser-induced phase-separation polymerization of a porous acrylate polymer is used for in-situ fabrication of dialysis membranes inside glass microchannels. A shaped 355 nm laser beam is used to produce a porous polymer membrane with a thickness of about 15 .mu.m, which bonds to the glass microchannel and forms a semi-permeable membrane. Differential permeation through a membrane formed with pentaerythritol triacrylate was observed and quantified by comparing the response of the membrane to fluorescein and fluorescently tagging 200 nm latex microspheres. Differential permeation was observed and quantified by comparing the response to rhodamine 560 and lactalbumin protein in a membrane formed with SPE-methylene bisacrylamide. The porous membranes illustrate the capability for the present technique to integrate sample cleanup into chip-based analysis systems.
Abstract Question: How do the diversity, size structure, and spatial pattern of woody species in a temperate (Mediterranean climate) forest compare to temperate and tropical forests? Location: Mixed evergreen coastal forest in the Santa Cruz Mountains, California, USA. Methods: We mapped, tagged, identified, and measured all woody stems (?1 cm diameter) in a 6-ha forest plot, following Center for Tropical Forest Science protocols. We compared patterns to those found in 14 tropical and 12 temperate forest plots. Results: The forest is dominated by Douglas-fir (Pseudotsuga menziesii) and three species of Fagaceae (Quercus agrifolia, Q. parvula var. shrevei, and Lithocarpus densiflorus), and includes 31 woody species and 8180 individuals. Much of the diversity was in small-diameter shrubs,...
SNAP25 occurs on chromosome 20p12.2, which has been linked to schizophrenia in some samples, and recently linked to latent classes of psychotic illness in our sample. SNAP25 is crucial to synaptic functioning, may be involved in axonal growth and dendritic sprouting, and its expression may be decreased in schizophrenia. We genotyped 18 haplotype-tagging SNPs in SNAP25 in a sample of 270 Irish high-density families. Single marker and haplotype analyses were performed in FBAT and PDT. We adjusted for multiple testing by computing q values. Association was followed up in an independent sample of 657 cases and 411 controls. We tested for allelic effects on the clinical phenotype by using the method of sequential addition and 5 factor-derived scores of the OPCRIT. Nine of 18 SNPs had P values <...
To study interactions between plants and plant-parasitic nematodes, several omics studies have nowadays become extremely useful. Since most data available so far is derived from sedentary nematodes, we decided to improve the knowledge on migratory nematodes by studying the transcriptome of the nematode Pratylenchus coffeae through generating expressed sequence tags (ESTs) on a 454 sequencing platform. In this manuscript we present the generation, assembly and annotation of over 325,000 reads from P. coffeae. After assembling these reads, 56,325 contigs and singletons with an average length of 353bp were selected for further analyses. Homology searches revealed that 25% of these sequences had significant matches to the Swiss-prot/trEMBL database and 29% had significant matches in nematode E...
The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...
For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
The purpose of this study was to evaluate the resin-dentin interfacial morphology and shear bond strength of several new and experimental dentin bonding systems classified as single-bottle/total etch, multi-step/total etch, and self-etching. Class 1 and 5 cavities were prepared from freshly extracted permanent molars and restored with composite resin. Each bonded sample was cross sectioned and one-half was completely demineralized and deproteinized, while the other half was polished along the cut surface to permit measurement of the thickness of resin-infiltrated dentin layer (RIDL) within intertubular dentin (iRIDL) and around the peritubular walls (pRIDL) of resin tags by SEM. Shear bond strength was measured for all the systems 2 minutes after photocuring. SEM showed iRIDL and resin tags of different morphology depending on material and dentin location. The iRIDL was thinner in superficial dentin and thicker in deep dentin. Peritubular RIDL ...
Remotely-fielded unattended sensor networks generally must operate at very low power--in the milliwatt or microwatt range--and thus have extremely limited communications bandwidth. Such sensors might be asleep most of the time to conserve power, waking only occasionally to transmit a few bits. RFID tags for tracking or material control have similarly tight bandwidth constraints, and emerging nanotechnology devices will be even more limited. Since transmitted data is subject to spoofing, and since sensors might be located in uncontrolled environments vulnerable to physical tampering, the high-consequence data generated by such systems must be protected by cryptographically sound authentication mechanisms; but such mechanisms are often lacking in current sensor networks. One reason for this undesirable situation is that standard authentication methods become impractical or impossible when bandwidth is severely constrained; if messages are small, a standard digital ...
Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).
The minimum cardiac transit times (MTT's) at rest and following sub-maximum stresses were measured in 97 individual examinations of untrained persons and high performance athletes. It turned out that there is a strong dependence on cardiac frequency of the MTT's. This relation can be described quite satisfactorily by a hyperbolic function and in this way allows a frequency correction to be made of the MTT's. The MTT's standardized in this way (MTT.f values) represent the quotient of the end diastolic segment volume/beat volume. In the whole lesser circulatory system almost identical MTT.f values were found for the two groups under comparison at rest and following stress. In the ventricles, however, and especially so in the left ventricle, the MTT.f values were clearly higher with athletes than with untrained persons, but they strongly decreased after stresses, while the respective values remained almost constant in ordinary persons. (orig./RF).
Local cardiac glucose utilization (LCarGU) was quantified in the rat heart according to the Sokoloff model and local cardiac blood flow (LCarBF) according to the /sup 14/C-iodoantipyrine method. For quantitative autoradiography calibration curves for heart slices were performed. They differed from the brain calibration curves by 8%. The lumped constant was 0.377 in isolated working hearts. LCarGU and LCarBF could then be quantified in awake rats. At different locations mean LCarGU of different hearts varied from 85 to 200 ..mu..moles/100g/min and mean LCarBF from 390 to 831 ml/100g/min. The ratio subendocardial/subepicardial glucose utilization or blood flow was not systematically different from 1. The results indicate that glucose can be an important fuel in the heart of the awake rat, although its contribution to overall metabolism varies from animal to animal.
The chicken extracellular matrix glycoprotein ES/130 is necessary for epithelial-mesenchymal transformation in the developing hear and is also expressed in noncardiac chicken tissues such as limb and notochord. We have identified hES, the human homology of chicken ES/130. Fluorescence in situ hybridization analysis (FISH) localizes hES to human chromosome 20p11.2-p12. FISH analyses of individuals with 20p12 deletions and affected by Alagille syndrome exclude hES as a candidate gene for this disorder. Reverse transcriptase-polymerase chain reaction studies reveal that hES is expressed in both fetal and adult human tissues and that hES expression in the left ventricle is increased in the failing adult heart. Further studies will evaluate how hES mutations may relate to congenital human cardiac and skeletal anomalies as well as cardiac remodeling in the adult. 16 refs., 2 figs.
1. The benzyl carbamyl analogue of lignocaine [2-(diethylaminoacetamido)-3-carbamyl-4-methyl-5-benzylpyrrole] at an intravenous dose of 4 mg/kg caused a blood pressure decrease of 54 mmHg. 2. A greater hypotensive effect was observed in hypertensive compared to normotensive animals. Anaesthesia magnified the vasodepressor effect in both groups. 3. The analogue did not possess centrally-mediated effects on blood pressure but exerted its hypotensive effect via a peripheral mechanism. 4. The analogue produced a relaxant effect on intestinal and vascular smooth muscle while exerting minimal effects on muscarinic, sympathetic, or ganglionic nicotinic receptors. 5. The analogue exhibited less cardiac depressant action on left ventricular rate (dp/dt) and force of contraction than lignocaine. 6. Lethal effects for the analogue were first observed at 16 mg/kg following intravenous administration and at 500 mg/kg following intraperitoneal administration. 7. In conclusion, ...
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...
The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available
PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available
This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available
A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.
Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available
Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available
Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available
Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available
This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.
The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available
Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available
Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...
An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
The atrial myocardium has been barely visible with thallium-201 myocardial scintigraphy. This is probably related to the difference in size, distance from anterior chest wall, and small coronary blood flow of the atrium, compared with the ventricle. We have encountered eight cases of visualization of the right atrial appendix (RAA). The RAA was identified from multiple projections in all cases and sometimes confirmed by radionuclide angiocardiography. Evidence derived from ECG, chest radiographs, and cardiac catheterization, indicated that the most important factor in the visualization might be the displacement of the RAA to a more anterior position.
A number of herbal drugs are used in the Unani (Greco-Arab) System of Medicine for cardiovascular diseases. The herbs were analyzed by flame AAS and ICP-AES to determine if their therapeutic actions can be associated with the elements present in them. Cadmium, cobalt, chromium, copper, iron, potassium, magnesium, manganese, sodium, nickel, phosphorus, lead and zinc were some of the elements which play various roles in cardiovascular affections. An effort was made to correlate the role of these elements in cardiac diseases. (Auth.). 2 tabs., 32 refs.
Purpose: To determine the value of MRI in the postoperativ evaluation of a singular ventricle compared to echocardiography and cardiac catheterization. Materials and methods: Thirty-one patients (range: 6 months to 30 years) with a functional single ventricle following palliative corrective operations. Five patients had a Blalock-Taussig-Shunt, 8 patients a Glenn-Anastomosis and 18 a cavopulmonary shunt (6 with classic Fontan-Circulation, 12 with modified cavopulmonary anastomosis). The results in terms of postoperative morphologic changes were compared to percutaneous echocardiography (31/31) and cardiac catheterization (6/31). Results: Echocardiography, which was performed on all patients, could not visualize the entire length of the tunnel, the Glenn-Anastomosis or the central pulmonary arteries in 70% of the patients due to an inadequate acoustic window. MRI was able to show the entire tunnel in 11/12 patients and the central pulmonary ...
Isolated laevocardia combined with corrected transposition of the great arteries and complete situs inversus is rare. Due to discordant interrelationships between atria and ventricles and between ventricles and great arteries, both anomalies result in a normal circulation. In the presented case no associated cardiac malformations were present and the 55-year-old woman remained symptom-free for a long time until she developed an acquired valve disease. A systematic approach to chamber localisation in complex morphologic lesions of the heart is reviewed, and the value of CT, which can be applied successfully in older children and adults is demonstrated. (orig.).
A 60-year-old male was bitten by a venomous snake (Vipera ammodytes) and gradually developed signs of an allergic reaction including generalized itching, generalized rash, and chest discomfort. This was followed by severe retrosternal pain with electrocardiographic evidence of an inferior myocardial ischemia progressing to acute myocardial infarction. Cardiac enzymes and troponin, serum tryptase, and histamine were elevated. Coronary arteriography showed normal coronary arteries. This is a characteristic type I variant of Kounis syndrome, which is the concurrence of acute coronary syndromes with conditions associated with mast cell activation including allergic or hypersensitivity reactions as well as anaphylactic or anaphylactoid reactions. This is the first report to show that viper bite...
Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.
The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
In dynamic cardiac SPECT estimates of kinetic parameters ofa one-compartment perfusion model are usually obtained in a two stepprocess: 1) first a MAP iterative algorithm, which properly models thePoisson statistics and the physics of the data acquisition, reconstructsa sequence of dynamic reconstructions, 2) then kinetic parameters areestimated from time activity curves generated from the dynamicreconstructions. This paper provides a method for calculating thecovariance matrix of the kinetic parameters, which are determined usingweighted least squares fitting that incorporates the estimated varianceand covariance of the dynamic reconstructions. For each transaxial slicesets of sequential tomographic projections are reconstructed into asequence of transaxial reconstructions usingfor each reconstruction inthe time sequence an iterative MAP reconstruction to calculate themaximum a priori reconstructed estimate. Time-activity curves for a sumof activity in a blood ...
Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)
A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.
An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.
This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.
Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...
Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and ...
Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...
The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided ...
We investigate theoretically subwavelength imaging by acoustic metamaterial slabs immersed in the liquid matrix. A near-field subwavelength image formed by evanescent waves is achieved by a designed metamaterial slab with negative mass density and positive modulus. A subwavelength real image is achieved by a designed metamaterial slab with simultaneously negative mass density and modulus. These results are expected to shed some lights on designing novel devices of acoustic metamaterials.
X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging
Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.
The computer vision approach to image analysis is discussed from two aspects. First, this approach is constrasted to the pattern recognition approach. Second, how external knowledge and information and models from other fields of science and engineering can be used for image and scene analysis is discussed. In particular, the connections between computer vision and computer graphics are pointed out.
The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.
Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.
This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.
The lymphographic agent Lipiodol (iodized oil) has been found to localize and remain in tumor vessels. Based on this finding, we attempted transcatheter internal radiotherapy by radioactive iodized oil (I-131 tagged Lipiodol) prepared by isotopic exchange reaction. Transcatheter internal radiotherapy (TCIR) was attempted in twelve patients with inoperable hepatoma by infusing a therapeutic dose of I-131 Lipiodol (7.6 approx. 28.3 mCi/2.0 approx. 5.0 ml) via the hepatic artery. Serial changes of serum alpha-fetoprotein (AFP) levels and in the size of tumor on computed tomography (CT) were estimated to evaluate the therapeutic effect. Serum AFP levels decreased in 9 patients with initial elevated levels of serum AFP, although they were again elevated in three of them within four weeks. More than 50 % decrease in tumor size was observed in 6 patients (50 %). There were no serious complications. This preliminary results suggest that TCIR with I-131 Lipiodol will be one ...
On February 20th 1998 Auckland, the biggest city of New Zealand, was nearly paralyzed by an extended power failure. On this day the last of four cables supplying the central business district failed and caused a five weeks lasting blackout. This failure has caused costs of 128.3 Mio NZ Dollar for the affected utility Mercury Energy Ltd. The official ministerial inquiry was published on July 21st 1998 and reproaches the utility in an unusual clear manner. (orig.) [Deutsch] Am 20. Februar 1998 wurde Auckland, die groesste Stadt Neuseelands, von einer folgenschweren Unterbrechung der Stromversorgung nahezu lahmgelegt. An diesem Tag fiel das letzte von vier 110-kV-Kabeln zur Versorgung des Innenstadtbereiches aus und verursachte damit einen 5 Wochen dauernden Stromausfall. Diese Versorgungsunterbrechung hat bisher Kosten in Hoehe von 128,3 Mio NZ Dollar (rd. 115,5 Mio DM) fuer den oertlichen Stromversorger Mercury Energy Limited verursacht. Der am 21. Juli 1998 ...
Being able to distinguish light-quark jets from gluon jets on an event-by-event basis could significantly enhance the reach for many new physics searches at the Large Hadron Collider. Through an exhaustive search of existing and novel jet substructure observables, we find that a multivariate approach can filter out over 95% of the gluon jets while keeping more than half of the light-quark jets. Moreover, a combination of two simple variables, the charge track multiplicity and the pT-weighted linear radial moment (girth), can achieve similar results. While this pair appears very promising, our study is only Monte Carlo based, and other discriminants may work better with real data in a realistic experimental environment. To that end, we explore many other observables constructed using different jet sizes and parameters, and highlight those that deserve further theoretical and experimental scrutiny. Additional information, including distributions of around 10,000 variables, can be found ...
Advanced proteomic research efforts involving areas such as systems biology or biomarker discovery are enabled by the use of high level informatics tools that allow the effective analysis of large quantities of differing types of data originating from various studies. Performing such analyses on a large scale is not feasible without a computational platform that performs data processing and management tasks. Such a platform must be able to provide high-throughput operation while having sufficient flexibility to accommodate evolving data analysis tools and methodologies. The Proteomics Research Information Storage and Management System (PRISM) provides a platform that serves the needs of the accurate mass and time tag approach developed at PNNL. PRISM incorporates a diverse set of analysis tools and allows a wide range of operations to be incorporated by using a state machine that is accessible to independent, distributed computational nodes. The system has scaled ...
A measurement of the t{bar t} production cross section at {radical}s = 1.96 TeV in the dilepton final states using a lepton+track selection and secondary vertex b-tagging is presented. One of the two leptons from the decay of the t{bar t} pair is allowed to be identified only as an isolated track to improve the selection efficiency. The result is combined with a measurement in the t{bar t} {yields} e{mu} final state. The measurements are based on 370 pb{sup -1} of data collected with the D0 experiment at the Tevatron collider. The preliminary cross section obtained in the combined lepton+track and e{mu} channel is: {sigma}{sub t{bar t}} = 8.6{sub -1.7}{sup +1.9}(stat) {+-} 1.1(syst) {+-} 0.6(lumi) pb.
Expressed sequence tags (ESTs) of the maxillary galea of the silkworm were analyzed to identify proteins involved in food selection systems. From the 1251 redundant genes of the ESTs, we identified 7 odorant-binding protein-like genes (bmObpL), 6 takeout-like genes (bmToL), and 6 chemosensory protein genes (bmCsp). Quantitative RT-PCR analysis indicated that bmObpL1, bmObpL2, bmObpL3, bmObpL5, bmToL1, bmToL3, and bmorCsp15 were predominantly expressed in the larval oral appendages, such as the maxilla, labrum, labium and antenna. Immunocytochemical analysis indicated that the proteins of bmObpL1, bmObpL3, and bmToL1 were localized in the gustatory chemosensilla on the maxillary galea and olfactory sensilla in the antenna. The proteins encoded by bmObpL1 and bmObpL3 were detected in the gus...
Until recently no active treatment for advanced or metastatic gastrointestinal stroma tumors (GIST) was available. The tyrosine kinase inhibitor imatinib has revolutionized the treatment of this disease and the median overall survival now reaches 5 years. The standard dose of imatinib is 400 mg per day. Locally advanced GIST should be treated with systemic therapy prior to surgical resection. Imatinib was recently licensed for adjuvant therapy following complete surgical removal of GIST in patients with a significant risk of recurrence. (orig.) [German] Bis vor einigen Jahren existierte keine wirksame systemische Therapie fuer fortgeschrittene oder metastasierte gastrointestinale Stromatumoren (GIST). Der Tyrosinkinaseinhibitor Imatinib hat die Behandlung dieser Tumoren revolutioniert, die mediane Ueberlebenszeit liegt heute bei etwa 5 Jahren. Die Standarddosierung von Imatinib betraegt initial 400 mg/Tag. Lokal fortgeschrittene Tumoren werden primaer systemisch ...
The ruptured offshore oil well 80 miles from Mexican town of Ciudad del Carmen, which poured 8000 barrels of light oil a day into the Gulf of Mexico, provided marine scientists with the opportunity to monitor the spill and see what happens to petroleum hydrocarbons in sea water. Scientists followed changes in viscosity, surface tension, and buoyancy of individual oil globs as they moved through the water and interacted with the surface slick. Using gas chromatography and mass spectroscopy, chemists are gaining an understanding of the unique characteristics of the oil. Computer-generated models projected the slick's movement in the Gulf in response to wind and wave pressures, but the sophisticated system did not give an accurate daily prediction. Immediate damage to fish, turtles, and sea birds was documented by tagging. Long-term effects will take longer to ascertain since 25 years is generally required to flush oil out of sediments. Fishermen do not agree ...
SNAP25 occurs on chromosome 20p12.2, which has been linked to schizophrenia in some samples, and recently linked to latent classes of psychotic illness in our sample. SNAP25 is crucial to synaptic functioning, may be involved in axonal growth and dendritic sprouting, and its expression may be decreased in schizophrenia. We genotyped 18 haplotype-tagging SNPs in SNAP25 in a sample of 270 Irish high-density families. Single marker and haplotype analyses were performed in FBAT and PDT. We adjusted for multiple testing by computing q values. Association was followed up in an independent sample of 657 cases and 411 controls. We tested for allelic effects on the clinical phenotype by using the method of sequential addition and 5 factor-derived scores of the OPCRIT. Nine of 18 SNPs had P values Irish family sample. Although we failed to replicate this in an independent sample, this gene should be further tested in other samples. PMID:19806613
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
Constrained least-squares techniques have been used to produce a well known class of image restoration algorithms. These techniques typically involve minimizing a linear operator on a vector representation of an image, subject to a constraint. For cases where an equality constraint is appropriate the method of Lagrange multipliers can be used to produce a restored image. In this work a fractal textural model, fractional Brownian motion, is used to represent images of interest. Using a variance fractal dimension estimator a non-linear operator, that represents the squared difference between the fractal dimension of the restored image and on a priori value is minimized, subject to the constraint that the norm of the residual between the restored image and available measurement equal the norm of the additive noise.
Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitized image version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and effectiveness of our approach for an efficient ...
The brain imaging properties of /sup 99m/Tc glucoheptonate, /sup 99m/Tc pertechnetate, and /sup 99m/Tc DPTA are compared. Results demonstrate that optimum images are obtained at 90, 180, and 180 min., for /sup 99m/Tc GH, /sup 99m/Tc DTPA, and /sup 99m/Tc pertechnetate, respectively. The former two images are not affected by prior bone imaging with /sup 99m/Tc pyrophosphate, while /sup 99m/Tc pertechnetate images are adversely affected. /sup 99m/Tc glucoheptonate appears to be the superior agent for brain imaging, followed by /sup 99m/Tc DTPA and /sup 99m/Tc pertechnetate.
A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.
Gallium imaging is increasingly being used for the early detection of complications in patients with AIDS. A 26-year-old homosexual man who was HIV antibody positive underwent gallium imaging for investigation of possible Pneumocystis carinii pneumonia. Widespread cutaneous focal uptake was seen, which was subsequently shown to be due to mycobacterium avium-intracellulare (MAI) septicemia. This case demonstrates the importance of whole body imaging rather than imaging target areas only, the utility of gallium imaging in aiding the early detection of clinically unsuspected disease, and shows a new pattern of gallium uptake in disseminated MAI infection.
Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed ...
Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in ...
X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast ...
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...
In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation ...
Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and ...
Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...
Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...
Hereditary hemorrhagic telangiectasia (Osler-Rendu-Weber disease) is a genetic disorder with autosomal dominance, variable penetrance, and an estimated prevalence of 1/10,000 inhabitants in France. Diagnosis is based on clinical criteria including epistaxis, telangiectasia, visceral manifestations, and familial occurrence. Pulmonary arteriovenous malformations, present in 15-33% of patients, are its primary visceral complications. The disease may be revealed by infectious and ischemic neurological manifestations due to paradoxical embolism. The high frequency of neurologic complications even in asymptomatic patients justifies systematic screening for pulmonary arteriovenous malformations. Treatment of these malformations is based on percutaneous transcatheter coil embolization of the feeding artery. Pulmonary arterial hypertension is rare in this disease. It may be due to systemic arteriovenous shunting in the liver, which increases cardiac output, or be similar to ...
Background Limited data is available for investigating the long-term safety and effects of intracoronary progenitor cell therapy in patients with acute myocardial infarction (AMI). Objective To assess the clinical course, NT-proBNP and MRI data as objective markers of cardiac function of the TOPCARE-AMI patients at 5-year follow-up. Design The TOPCARE-AMI trial was the first randomized study investigating the effects of intracoronary infusion of circulating (CPC) or bone marrow-derived progenitor cells (BMC) in 59 patients with successfully reperfused AMI. Results Five-year follow-up data were completed in 55 patients, 3 patients were lost to follow-up. None of the patients showed any signs of intramyocardial calcification or tumors at 5?years. One patient died during the initial hospitali...
Objective Comorbidities predisposing cardiac surgical patients toward deep sternal wound infection, such as diabetes and obesity, are rising in the United States. Longitudinal analysis of risk factors, morbidity, and mortality was performed to assessed effects of these health trends on deep sternal wound infection rates. Methods In this retrospective analysis of all median sternotomies performed at a single institution from 1991 through 2006, demographic and surgical characteristics were identified from a prospective database. The cohort was separated into periods from 1992 through 2001 and 2002 through 2006 to identify longitudinal trends in risk factors for deep sternal wound infection. Univariate and matched multivariable analyses were performed. Results Overall, study population had in...
The random walk function is a mathematical function derived from studies of the mass transport and flow of diffusible materials through tubes. Approximations to the function were first used some time ago in the field of cardiac tracer dilution curves, but in the absence of rapid and reproducible curve fitting the method never became commonplace. The current study uses the latest curve-fitting techniques and shows how the method may be used with precision in the analysis of time-activity curves from dynamic oesophageal and blood flow studies. The physiological basis of the method is given and parameters obtained which relate to both the rate of flow and the local dispersion of the bolus.
Cellular telephones emit a radiofrequency electromagnetic field, part of which is absorbed in the user's head. Many studies have been conducted to look for their possible health hazard to human, at the experimental, epidemiological or clinical level. After a short recall on dosimetry, the author describes the state-of-the art about harmful and irreversible effects, up to now not confirmed, and about some benign symptoms which look absolutely actual. A causal relationship of the electromagnetic field on these benign symptoms is however not proven; other, studies are running to evaluate their possible long-term consequences. Interferences with cardiac pacemakers can easily be avoided by holding the telephone handset farther than 10 cm. (author)
Background/Objectives: Cardiotoxic drug poisoning can lead to severe cardiac shock (CS) and death. B-type natriuretic peptide (BNP) is a well-established diagnostic and prognostic marker in heart failure but has never been assessed in patients with cardiotoxic drug poisoning. The aim of the study was to determine whether BNP could be useful for early stratification of patients admitted to intensive care unit. Methods: 30 consecutive patients experiencing shock and cardiotoxic drug exposure were enrolled in a prospective monocentric study and underwent at least two BNP measurements within the first 24 h after admission. Results: While BNP values on admission were poorly informative, subsequent BNP measurements (11 +- 6 h after admission) were significantly increased in patients with CS comp...
Animal studies demonstrated the powerful impact of maternal-infant social contact on the infant's physiological systems, yet the online effects of social interactions on the human infant's physiology remain poorly understood. Mothers and their 3-month old infants were observed during face-to-face interactions while cardiac output was collected from mother and child. Micro-analysis of the partners' behavior marked episodes of gaze, affect, and vocal synchrony. Time-series analysis showed that mother and infant coordinate heart rhythms within lags of less than 1s. Bootstrapping analysis indicated that the concordance between maternal and infant biological rhythms increased significantly during episodes of affect and vocal synchrony compared to non-synchronous moments. Humans, like other mamm...
Background The Norwood procedure consists of three palliative operations, performed in neonates with hypoplastic left heart syndrome. Especially the first stage (Norwood I) is associated with the highest mortality rates in paediatric cardiac surgery (up to 25%). During surgery, the aorta is reconstructed and a systemic-to-pulmonary shunt is applied. Originally the modified Blalock-Taussig shunt was used, but recently the right-ventricle-to-pulmonary-artery shunt is increasingly being employed. We reviewed the results of our operative strategy, where an individualised choice of shunt is made. Furthermore, attempts to reduce interstage mortality (between Norwood I and II) were assessed. Methods All neonates who underwent Norwood stage I palliation from August 2004 until November 2010 were in...
The authors used studies of local cerebral metabolic rate for glucose (LCMRGlc) to examine development of cerebral organization in 5 days to 1 year old children. A group (n=8) of infants with diverse pediatric disorders allowed investigation of developmental changes in LCMRGlc, while also providing relevant clinical management information. Patients consisted of questionable and definite neonatal seizures, cerebral embolism from cardiac sources, and otherwise normal infants with facial nevi with consideration of Sturge-Weber. Gradual increase in cortical LCMRGlc coincides with suppression of intrinsic subcortical reflexes present in all newborns. Two retarded children (2 years old) showed LCMRGlc developmental patterns of a few days old, which corresponded to their functional and mental status. These studies illustrate great potential of PET to study normal and altered states of human brain development.
Abstract A series of studies performed at our center demonstrates that gaseous microemboli (GME) remain a challenge in cardiac surgical procedures. Evaluation of novel oxygenators must address hemodynamic parameters and microemboli capture capability. The objective of this study is to compare two neonatal membrane oxygenators, the Quadrox i (MAQUET Cardiopulmonary AG, Hirrlingen, Germany) and the Capiox RX05 (Terumo Corporation, Tokyo, Japan), with respect to GME capture and hemodynamic energy delivery. The experimental circuit included a Maquet HL 20 heart lung machine, a Heater Cooler Unit HCU 30 (MAQUET Cardiopulmonary AG), a membrane oxygenator (Quadrox i Neonatal or Capiox RX05), and inch tubing from the COBE Heart/Lung Perfusion Pack (COBE Cardiovascular, Inc., Arvada, CO, USA). A Ca...
Aim:To examine the electrophysiological effects of sophocarpine on action potentials (AP) and ionic currents of cardiac myocytes and to compare some of these effects with those of amiodarone.Methods:Langendorff perfusion set-up was used in isolated guinea pig heart, and responses to sophocarpine were monitored using electrocardiograph. Conventional microelectrode, voltage clamp technique and perforated patch were employed to record fast response AP (fAP), slow response AP (sAP) and ionic currents in guinea pig papillary muscle or rabbit sinus node cells.Results:Tachyarrhythmia produced by isoprenaline (15 ?mol/L) could be reversed by sophocarpine (300 ?mol/L). Sophocarpine (10 ?mol/L) decreased the amplitude by 4.0%, maximal depolarization velocity (Vmax) of the fAP by 24.4%...
BACKGROUND AND PURPOSE In spite of its widespread clinical application, there is little information on the cellular cardiac effects of the antidiabetic drug rosiglitazone in larger experimental animals. In the present study therefore concentration-dependent effects of rosiglitazone on action potential morphology and the underlying ion currents were studied in dog hearts. EXPERIMENTAL APPROACH Standard microelectrode techniques, conventional whole cell patch clamp and action potential voltage clamp techniques were applied in enzymatically dispersed ventricular cells from dog hearts. KEY RESULTS At concentrations -10-M rosiglitazone decreased the amplitude of phase-1 repolarization, reduced the maximum velocity of depolarization and caused depression of the plateau potential. These effects d...
Electric utilities have been surprised by recent opposition to the construction of very-high-voltage transmission lines, which met with little resistance in the past. Concerns over health and safety factors are associated with the increase in the number of such lines, although their presence has always been an inconvenience and a hazard for those living and working in the immediate vicinity. The new lines present additional hazards due to the continuous flow of small electric currents and the charges that build up in the area of the towers and lines. The lines are also a threat to persons wearing cardiac pacemakers. There is experimental evidence from the Soviet Union and the U.S. that electric and magnetic fields at the frequencies of such power lines can have serious biological effects on growth rates and the functioning of the central nervous system. Full disclosure that possible risks are involved and the opportunity to avoid these risks is a public ...
Self-excited oscillations of a distributed medium can be investigated in terms of discrete physical models described by multidimensional systems of nonlinear equations which transform into equations of self-oscillating distributed media as the number of dimensions goes to infinity. Differential equations of such a self-oscillating system are set up and investigated. Coupling between elements of the medium, conditions under which the system constitutes an open system, internal impedance between the energy source and the system elements, and boundary conditions defining open and closed systems are discussed. The Gunn effect, eolian noise, self-oscillations of DNA molecules and of cardiac muscle, and wave processes in the cerebral cortex are mentioned as examples of self-oscillatory processes in question.
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
Twenty patients with lesions in the trachea or bronchus underwent energy subtraction Fuji computed radiography (FCR). Images obtained were compared with those from conventional FCR (plain FCR). ''Very clear'' images (in which the contour of the trachea and bronchus could be clearly defined) were obtained in 12/22 (55 %) by energy subtraction FCR and in 3/22 (14 %) by plain FCR; ''clear'' images (in which the contour could be defined) in 9/22 (41 %) by energy subtraction FCR and in 18/22 (82 %) by plain FCR; and ''unclear'' images (in which the contour could not be defined) in 1/22 (5 %) by both methods. Energy subtraction FCR, as well as plain FCR, yielded high image quality for the trachea. Energy subtraction FCR was superior to plain films when tumors existed within the trachea. (Namekawa, K.).
Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...
Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).
A multiprocessor architecture inspired by the Disney multiplane camera is proposed. For many applications, this approach produces a natural mapping of processors to objects in a scene. Such a mapping promotes parallelism and reduces the hidden-surface work with minimal interprocessor communication and low-overhead cost. Existing graphics architectures store the final picture as a monolithic entity. The architecture here stores each object's image separately. It assembles the final composite picture from component images only when the video display needs to be refreshed. This organization simplifies the work required to animate moving objects that occlude other objects. In addition, the architecture has multiple processors that generate the component images in parallel. This further shortens the time needed to create a composite picture. In addition to generating images for animation, the ...
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).
This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...
An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more ...
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of ...
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best ...
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...
Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...
Power system analysis shows the output from the solar arrays varies as a function .... Each array corresponds to a raw image browse product, which is generated by .... low outgassing, ability to withstand long-term exposure to the space ...
Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to ...
Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available
Many simulation studies in biomedicine are based on a similar sequence of processing steps, starting from images and running through geometric model generation, assignment of tissue properties, numerical...Full Text Available
To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...
The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.
Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.
This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available
This review presents a summary of existing knowledge regarding the impact of testicular cancer along four broad domains, including romantic and sexual relationships, body image, and fertility....Full Text Available
Motivated by the observation that a retinal fundus image may contain some unique geometric structures within its vascular trees which can be utilized for feature matching, in this paper, we proposed...Full Text Available
Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available
Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available
An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available
To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe ...
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available
Cancer immunotherapies can be guided by cellular imaging techniques, which can identify the presence or absence of immune-cell accumulation in the tumor tissue in-vivo and in real time. This...Full Text Available
OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available
BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available
This volume contains the proceedings of a symposium entitled In Vivo Imaging of Neurotransmitter Function in Brain, Heart, and Tumors'' held August 24--25, 1990 in Montreal Canada. The six individual papers contained herein are separately abstracted and indexed for the database.
BACKGROUND: Although the importance of lymphatic function is well recognized, the lack of real-time imaging modalities limits our understanding of its role in many diseases. In a phase...Full Text Available
Background and Objectives:Sound enamel manifests peak transparency in the near-IR (NIR) at 1310-nm, therefore the near-IR is ideally suited for high contrast imaging...Full Text Available
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...
RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available
A two-channel optical system has been developed to provide spatially resolved simultaneous imaging of singlet molecular oxygen (1O2) phosphorescence and photosensitizer (PS) fluorescence...Full Text Available
The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique...Full Text Available
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...
This paper hopes to share the insights we experienced during designing, building, and running an indexing solution for a large set of radiological reports and images in a production environment for...Full Text Available
Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available
We describe a closed-loop brain-computer interface that re-ranks an image database by iterating between user generated 'interest' scores and computer vision generated visual similarity measures. The interest scores are based on decoding the electroencephalographic (EEG) correlates of target detection, attentional shifts and self-monitoring processes, which result from the user paying attention to target images interspersed in rapid serial visual presentation (RSVP) sequences. The highest scored images are passed to a semi-supervised computer vision system that reorganizes the image database accordingly, using a graph-based representation that captures visual similarity between images. The system can either query the user for more information, by adaptively resampling the database to create additional RSVP sequences, or it can converge to a 'done' state. The done state includes a ...
Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available
Functional imaging has revolutionized the neurosciences. In the pain field it has dramatically altered our understanding of how the brain undergoes significant functional, anatomical and chemical changes...Full Text Available
The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available
Antisense radiopharmaceuticals could be used to image gene expression in the brain in vivo, should these polar molecules be made transportable through the blood–brain barrier....Full Text Available
We studied 64 ADHD children patients group (4 {approx} 15 ys, mean age: 8 {+-} 2.6 ys. M/F: 52/12) and 12 normal group (6 {approx} 7 ys, mean age: 9.4 {+-} 3.4 ys, M/F: 8/4) of the brain had been used to analysis of blood flow between normal and ADHD group. For analysis of Children ADHD, we used 12 children's mean brain images and made Template image of SPM99 program. In crease of blood flow (P-value 0.05), the result of normalized images to Template image to offer from SPM99 program, showed significant cluster in inter-Hemispheric and occipital Lobe, in the case of normalized images to children template image, showed inter-hemispheric and parietal lobe.
Software for gel image analysis and base-calling in fluorescence-based sequencing consisting of two primary programs, BaseFinder and GelImager, is described. BaseFinder is a framework for trace processing,...Full Text Available
BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available
Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).
The patch and voxel methods are representative examples of the ways in which multi-slice images may be displayed three-dimensionally by means of computer-graphics. Each of them have advantages and disadvantages and they are mutually complementary. We have developed algorithms for a modified voxel method which incorporates the advantages of the patch methods. We have applied this to the three-dimensional image display of brain tumor with excellent results. The three-dimensional reconstructions used for clinical application in this study were derived from X-ray CT images.
The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.
Disaster impact modeling and analysis uses huge volumes of image data that are produced immediately following a natural or an anthropogenic disaster event. Rapid damage assessment is the key to time critical decision support in disaster management to better utilize available response resources and accelerate recovery and relief efforts. But exploiting huge volumes of high resolution image data for identifying damaged areas with robust consistency in near real time is a challenging task. In this paper, we present an automated image analysis technique to identify areas of structural damage from high resolution optical satellite data using features based on image content.
There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging
Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-guided biopsies, aspirations and small bore chest drain placement, all of which have been shown to be safe and efficacious. Pneumothoraces occurring due to acute trauma and in an intensive care setting can also benefit from radiological input, both in terms of diagnosis and image-guided treatment. (orig.)
Multitemporal TM images are used to collect information about the extension and variation of water influx subsidence in coal district in order to provide a reference for the harnessing and utilization of water influx subsidence. The multitemporal TM images are used as a blended data group for the analysis of the principal components to reflect the expanding water influx subsidence in the past years. Because of the differences in the environment and imaging condition, 'unitary' order is used to enhance the 'coherence' and 'comparability' of the original TM images. 5 refs., 4 figs., 2 tabs.
/sup 99m/Tc biliary imaging was performed on a 34-year-old woman who was being investigated for suspected cholelithiasis. A left-sided liver was detected. On subsequent radionuclide imaging, partial visceral situs inversus and asplenia were demonstrated. Extensive roentgenographic investigation, ECG, echocardiogram, and laparotomy confirmed the radionuclide findings. Asplenia syndrome may exist without cardiovascular abnormalities and thus be undiscovered. Radionuclide imaging is important in the diagnosis of this syndrome.
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
Peripheral primitive neuroectodermal tumors (peripheral PNETs) are rare in the abdomen. We report the imaging findings of four peripheral PNETs arising in the abdomen. Three were ill-demarcated tumors and one was a well-demarcated tumor, with extensive local invasion and lymph node metastasis in two cases, respectively. The tumors are of inhomogeneous attenuation and heterogeneous enhancement after intravenous administration of contrast materials. Although their imaging manifestations cannot distinguish them from other sarcomas, recognition of these imaging features may be helpful in suggesting the possibility of peripheral PNETs in some cases.
A carbon nanotube (CNT) tip, which assembled on the sharp end of a Si tip by dielectrophoresis, was structurally modified using focused ion beam (FIB). We described the imaging characterization of the FIB-modified CNT tip in noncontact AFM mode in terms of wear, deep trench accessibility, and imaging resolution. Compared to a conventional Si tip, the FIB-modified CNT tip was superior, especially for prolonged scanning over 10 h. We conclude that modified CNT tips have the potential to obtain high-quality images of nanoscale structures.
... is the sensor that converts incoming photons into a ... with CCD foundries to acquire such a sensor. ... 2007, Journal of Spacecraft and Rockets, 44, 910 ...
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
ARIES Baker-Nunn Schmidt telescope project is converting a Baker-Nunn satellite tracking camera for Astronomical research. Original Baker-Nunn camera produces an extremely large (5X30 degree) curved focal plane at the prime focus for photographic imaging. We present here the re-designing of the camera produces a wide (4 X 4 degree) flat field of view for CCD imaging observations, which have many scientific potentials in Astronomy. Imaging performance of the CCD camera is also estimated.
This book constitutes the thoroughly refereed post proceedings of the international workshop Computer Vision Approaches to Medical Image Analysis, CVAMIA 2006, held in Graz, Austria in May 2006 as a satellite event of the 9th European Conference on Computer Vision, EECV 2006. The 10 revised full papers and 11 revised poster papers presented together with 1 invited talk were carefully reviewed and selected from 38 submissions. The papers are organized in topical sections on clinical applications, image registration, image segmentation and analysis, and the poster session. (orig.)
Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).
The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes. (orig.).
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
... order probabilistic modelling, multisensor monitoring of ... object recognition, image registration and point ... of the Berkeley Continuous Media Toolkit. ...
The field of stem cell research was revolutionized with the advent of induced pluripotent stem cells. By reprogramming somatic cells to pluripotent stem cells, most ethical concerns associated with the use of embryonic stem cells are overcome, such that many hopes from the stem cell field now seem a step closer to reality. Several methods and cell sources have been described to create induced pluripotent stem cells and we discuss their characteristics in terms of feasibility and efficiency. From these cells, cardiac progenitors and cardiomyocytes can be derived by several protocols and most recent advances as well as remaining limitations are being discussed. However in the short time period this technology has been around, evidence emerges that induced pluripotent stem cells may be more prone to genetic defects and maintain an epigenetic memory and thus may not be entirely the same as embryonic stem cells. Despite the lack of a complete fundamental understanding ...
The effect of exercise training prior to acute myocardial infarction (AMI) on left ventricular (LV) remodeling is poorly understood. This study investigated the protective effect of 3 weeks of swimming exercise training prior to AMI on cardiac morphology and function. Male Sprague-Dawley rats (n = 35) were randomly assigned to 3 groups: swimming training (n = 14, 90 min, 5 days/wk, 3 wk), sedentary (n =14), and controls (n = 7, no exercise, no MI). At the end of the training/sedentary period, rats were subjected to AMI (ExMI and SedMI) induced by surgical ligation of the left coronary artery. Thereafter, the rats remained sedentary for a 4-wk recovery period. Trans-thoracic echocardiography was performed in each group at the end of the exercise/sedentary period (pre-AMI), 24 hr after AMI, and following recovery (4 wk after AMI). No differences were observed in LV dimensions and function pre-AMI among the 3 groups; however, LV-end systolic diameter (LVESD) and ...
Male rats were injected intravenously for 15 min with physiological saline (as control) (0.05 #mu#g/kg/min) or norepinephrine (NE) (0.1 #mu#g/kg/min) followed by 740 kBq of MIBG. Rats were injected for more 30 min (early stage group) and for more 4 hr (late stage group) with physiological saline or NE. Five MBq of "9"9"mTc-tetrofosmin (TF) was administered instead of MIBG in another group. The heart was isolated and uptake of MIBG or TF of right ventricle, apex, and left ventricle (divided into 8 parts) was measured. In control group, MIBG uptake of apex was significantly lower than that of lateral wall in both early and late groups. In NE group, MIBG uptake showed a tendency to decrease in both early and late groups. Compared with control group, the uptake of anterior wall in late group decreased significantly at NE 0.1 #mu#/kg/min. The TF uptake in control group was not different in each part. In NE group, the TF uptake of right ventricle decreased significantly compared with that of ...
A hypothesis of microwave-induced circulatory under perfusion was tested in ketamine anesthetized rats whose heart rate, mean arterial pressure, pulse pressure, respiration rate, and body temperatures were monitored continuously. Fifty-eight ventral head and neck exposures in a waveguide consisted of sham-exposure and exposure to continuous wave (CW) and pulsed 1.25 GHz microwaves for 5 min. The 0.5 Hz and 16 Hz pulsemodulated microwaves were delivered at 400 kW peak power. The CW microwaves were 2 and 6.4 W. The average specific absorption rate was 4.75 W/kg per watt transmitted in the brain and 17.15 W/kg per watt transmitted in the neck. Respiration rate and mean arterial pressure were not altered. Changes in heart rate and pulse pressure were observed in rats exposed to higher power but not to the lower average power microwaves. Depression of pulse pressure, an indication of a decrease in stroke volume, and increased or decreased heart rate were noted in presence of whole-body ...
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)
Parathyroid imaging based on the principle of differential uptakes of Tc-99m and T1-201 in the anterior neck to localize parathyroid (PT) disease has been reported with widely varying results. To evaluate the usefulness of this method, we have performed PT imaging on 47 patients prior to exploratory surgery for PT disease. Using pinhole collimation and digital acquisition, a 50k count image of the thyroid was obtained 20 minutes after injection of 1mCi99m Tc-pertechnetate. Then a lmCi dose of Tl-201 chloride was injected and a series of images acquired for 30 minutes at 30 sec/image. Raw data was spatially filtered and normalized by summing sufficient T1-201 images to equal the Tc-99m image scale of maximum cts/pixel. Image subtraction (Tl-Tc) gave the final PT image. Of 10 pts who had previous neck ...
Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.
For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
In this article, the authors recall the factors apt to influence image quality in NMR Imaging and present the european works that have been developed in MRIQA to set 5 quality assurance tests: EUROSPIN 1 to 5.
Sponsored by the Defense Advanced Research Projects Agency the Image Understanding Workshop is a forum for the presentation of new research in vision, image analysis, and geometric modeling. Leading scientists present overviews of projects underway at major universities and corporate research sites, as well as results of individual work. The 1987 volume contains 94 articles and technical reports in two volumes.
The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper
Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).
The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).
An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.
A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.
The "1"3"1I-labelled monoclonal antibodies 791T/36 and 79IT/36 Fab fragments have been evaluated in the imaging of patients with colorectal cancer, with benign colorectal tumours, and with malignant tumours of other parts of the gastrointestinal tract. The results of clinical imaging have been carefully correlated with clinical findings and direct measurement of the preferential uptake of antibody by the tumours. (UK).
A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available
We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).
The authors report an extension of the source imaging method for analyzing three-dimensional sources from three-dimensional correlations. The technique consists of expanding the correlation data and the underlying source function in spherical harmonics and inverting the resulting system of one-dimensional integral equations. With this strategy, they can image the source function quickly, even with the extremely large data sets common in three-dimensional analyses.
We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)
In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.
Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available
Purpose: To report on the nephron-sparing, percutaneous ablation of a large renal cell carcinoma by combined superselective embolization and percutaneous radiofrequency ablation. Materials and Methods: A 5 cm renal cell carcinoma of a 43-year-old drug abusing male with serologically proven HIV, hepatitis B and C infection, who refused surgery, was superselectively embolized using microspheres (size: 500 - 700 {mu}m) and a platinum coil under local anesthesia. Percutaneous radiofrequency ablation using a 7F LeVeen probe (size of expanded probe tip: 40 mm) and a 200 Watt generator was performed one day after transcatheter embolization under general anesthesia. Results: The combined treatment resulted in complete destruction of the tumor without relevant damage of the surrounding healthy renal tissue. The patient was discharged 24 hours after RF ablation. No complications like urinary leaks or fistulas were observed and follow up CT one day and 4 weeks after the radiofrequency ...
MR images of steady and pulsatile disturbed flow, obtained with use of flow-compensated spin-echo (SE) and cine pulse sequences, revealed excellent flow visualization in three dimensions. Phantoms, built from molds of actual blood vessels, reproduced laminar, disturbed, or turbulent flow. Video recording (VR), performed under conditions equivalent to those of the MR experiments, showed separation zones identical to those seen on SE images. Pulsatile flow studies showed complex patterns of vortical flow on cine images and VR. Varying pulse sequence details changed contrast but not flow patterns. The validation of MR observations by VR has implications for clinical cine imaging and low abnormal signals observed on MR angiograms.
We introduce a multi-layered image cache system that is designed to work with a pool of rendering engines to facilitate an interactive, frameless, asynchronous rendering environment. Our system decouples the rendering from the display of imagery. Therefore, it decouples render frequency and resolution from display frequency and resolution, and allows asynchronous transmission of imagery instead of the compute/send cycle of standard parallel systems. It also allows local, incremental refinement of imagery without requiring all imagery to be re-rendered. Images are placed in fixed position in camera (vs. world) space to eliminate occlusion artifacts. Display quality is improved by increasing the number of images. Interactivity is improved by decreasing the number of images.