WorldWideScience
 
 
1

Vacuum system pump down analysis  

Energy Technology Data Exchange (ETDEWEB)

My assignment on the SP-100 Vacuum Vessel Vacuum System Team was to perform a transient pump down analysis for the vacuum vessel that will house the SP-100 reactor during testing. Pump down time was calculated for air and helium. For all cases the proposed vacuum system will be able to pump down the vessel within the required time. The use of a larger rotary piston pump (DUO250) improves the pump down time by 35 minutes and therefore should be considered. The 6-inch duct for the roughing line is optimal, however, because all cases are well below the 24 hour time frame, the 4-inch duct is sufficient. The use of the single turbomolecular pump during pump down is sufficient. A pump down with helium in the vessel and a helium inleakage delays the time to achieve the base pressure marginally and is acceptable.

1990-08-01

2

Biosorption of americium-241 by Candida sp.  

Energy Technology Data Exchange (ETDEWEB)

As an important radioisotope in nuclear industry and other fields, americium-241 is one of the most serious contamination concerns duo to its high toxicity and long half-life. In this experiment, the biosorption of {sup 241}Am from solution by Candida sp., and the effects of various experimental conditions on the adsorption were investigated. The preliminary results showed that the adsorption of {sup 241}Am by Candida sp. was efficient. {sup 241}Am could be removed by Candida sp. of 0.82 g/L (dry weight) from {sup 241}Am solutions of 5.6-111 MBq/L (44.3-877.2 {mu}g/L)(C{sub 0}), with maximum adsorption rate (R) of 98% and maximum adsorption capacities (W) of 63.5 MBq/g biomass (dry weight) (501.8 {mu}g/g). The biosorption equilibrium was achieved within 4 hour and the optimum pH was pH = 2. No significant differences on {sup 241}Am adsorption were observed at 10 C-45 C, or in solutions containing Au{sup 3+} or Ag{sup +}, even 1500 times or 4500 times above the {sup ...

2003-07-01

3

Biosorption of Americium-242 by saccharomyces cerevisiae: preliminary evaluation and mechanism  

International Nuclear Information System (INIS)

As an important radioisotope in nuclear industry and other fields, americium-241 is one of the most serious contamination concerns duo to its high radiation toxicity and long half-life. In this experiment, the biosorption of "2"4"1Am from solution by a fungus, Saccharomyces cerevisiae (S. cerevisiae), and the effects of various experimental conditions on the biosorption and the mechanism were explored. The preliminary results showed that S. cerevisiae is a very efficient biosorbent. An average of more than 99% of the total "2"4"1Am could be removed by S. cerevisiae of 2.1g/L (dry weight) from "2"4"1Am solutions of 2.22MBq/L -555 MBq/L (Co). The adsorption equilibrium was achieved within 1 hour and the optimum pH ranged 1-3. The culture times of more than 16 hours were suitable and the efficient adsorption of 241Am by the S. cerevisiae could be noted. The biosorption of 241Am by the decomposed cell wall, protoplasm or cell membrane of S. cerevisiae was same ...