The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with ...
A four-stage scoring system for brain maturation was established with MR imaging. First, gyration and myelination were analyzed in 50 anamnestically normal children (32-240 weeks postconceptional age). Subsequently 60 patients (same age range) with birth asphyxia, seizures, or developmental delays were evaluated analogously. T1- and T2-weighted images (500/30 and 3,000/120 [repetition time msec/echo time msec]) were obtained with a 2.35-T magnet in all children. Whereas gyration abnormalities were seen in some patients, all handicapped children presented with delayed myelination. In conclusion, prospective staging of brain development (gyration and myelination) is possible and is best obtained with T2-weighted images.
Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).
The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided ...
Magnetic resonance imaging (MRI) was used to evaluate 22 histological proven peripheral nerve sheath tumors, approximately two-thirds of which arose in the lower extremity. The histologic distribution was as follows: 12 schwannomas, 7 neurofibromas, and 3 malignant peripheral nerve sheath tumors (2 of which occurred in patients with neurofibromatosis). Most lesions demonstrated an intermediate to moderately bright signal on T_1-weighted images and were minimally inhomogeneous. All lesions were moderately bright on T_2-weighted images, again with variable inhomogeneity. The extent of the tumor was best assessed on proton-density- and T_2-weighted images. Smooth margins were noted in 19 lesions. Of the 3 remaining lesions, 2 were malignant (but had been subjected to biopsy prior to MRI), and the other lesion was a plexiform neurofibroma. MRI ...
Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of ...
Objective: To compare the histopathology of nodular fasciitis (NF) with the magnetic resonance imaging (MRI) findings in order to evaluate the basis of the MR signal characteristics. Design and patients: Ten patients with NF, nine females and 1 male, with an age ranging from 13 to 58 years (mean 26.8 years) were studied. MRI findings, available in all 10 patients, were compared with the histopathology in nine patients, and an area-to-area comparative study of the whole specimen section histopathology and MRI was performed in two patients. Results: On the basis of an excisional biopsy or resection specimen, the nine lesions were classified into myxoid (n=4), cellular (n=3) and fibrous (n=2) subtypes. Four myxoid lesions with a subcutaneous location showed a homogeneous SI comparable with muscle on T1-weighted images, high SI on T2-weighted images, and had homogeneous enhancement. One cellular lesion ...
To assess the utility of magnetic resonance (MR) imaging in the study of pediatric patients with clinical suspicion of pituitary disease. We studied 18 patients aged 7 to 18 years.Fifteen had hormonal disturbances, two presented amenorrhea and 1 complained of headache, fever and symptoms of polyuria and polydipsia. All the patients were examined using a Siemens SP 42 1-Tesla MRI scanner. Sagittal and coronal T1-weighted spin-echo images were obtained; in addition T2-weighted spin-echo or fast spin-echo imaging was performed in ten cases and intravenous gadolinium was administered in nine. We found 9 patients with hypothalamic-pituitary dysgenesis, 2 with germinoma, 2 cases of pituitary hemosiderosis in patients with thalassemia, 2 cases of microadenoma, one abscess, one case of idiopathic central diabetes insipidus and one of Langerhans cell histiocytosis. MR enabled us to assess pituitary structural ...
To determine MTRs for normal structures and benign diseases in the breast two-dimensional magnetization transfer imaging was performed in 62 patients and in 3 young female volunteers. With regard to the MTRs of measurements in the normal breast tissues, fat tissues which is close to simple cysts in MTRs show little transfer of longitudinal magnetization. MTRs of the muscles was 15.15{+-}6.22%, which exceeded those of breast parenchyma. The breast parenchyma didn`t show the change of MTR value due to the difference of patient age and due to variable amount of fat and fibrous tissues. Breast parenchyma in the two young volunteers clearly showed biphasic change of MTR values in accordance with the menstrual cycle; little transfer value was due to hydration in the postovulatory period and high transfer value was due to dehydration in the preovulatory period. In the remaining one volunteer during lactation period, mammary parenchyma shows sever ...
Normal fetal brain maturation can be studied by in vivo magnetic resonance imaging (MRI) from the 18th gestational week (GW) to term, and relies primarily on T2-weighted and diffusion-weighted (DW) sequences. These maturational changes must be interpreted with a knowledge of the histological background and the temporal course of the respective developmental steps. In addition, MR presentation of developing and transient structures must be considered. Signal changes associated with maturational processes can mainly be ascribed to the following changes in tissue composition and organization, which occur at the histological level: (1) a decrease in water content and increasing cell-density can be recognized as a shortening of T1- and T2-relaxation times, leading to increased T1-weighted and decreased T2-weighted intensity, respectively; (2) the ...
Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better on the TIRM images than on the other sequences. In the other cases, the TIRM signal ...
Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature ...
We examined the physiology of continence in 12 patients at least four months after colectomy, mucosal proctectomy, and endorectal ileo-anal anastomosis for ulcerative colitis and familial polyposis....Full Text Available
The role of MRT in the prebiopsy diagnosis of muscular and vascular inflammatory conditions was evaluated prospectively and an optimal method of examination was investigated. 92 patients with a suspected diagnosis of myositis (60 cases) or vasculitis (32 cases) were examined, in each case two extremities were studied using transverse T_1 and T_2weighted SE sequences and double echo STIR sequences on a 0.5 Tesla (56 patients) or 1.5 Tesla magnet (36 patients; T5/S15 Gyroscan, Philips). The site of the biopsy depended on the MRT findings. In 41 patients the suspected diagnosis was confirmed histologically, in two patients an infective myositis was diagnosed on clinical grounds despite negative histology. MRT demonstrated muscle oedema in 86% of patients. There were negative findings after immuno-suppressive therapy (two patients), in focal myositis (3 out of 4 patients) and in one of 7 patients with ...
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors were homogeneous and ...
MRI, ultrasonography and angiography were performed on 24 cases with small renal cell carcinoma, and data were compared with pathological architecture type. An average diameter of cancer was 20.8 mm (10-30 mm). Each tumor was pathologically classified into four architecture types: alveolar type (15 cases), papillary type (5 cases), tubular type (3 cases) and cystic type (1 case). In comparison with renal cortex alveolar type renal cell carcinoma showed equal or low signal in T1-weighted images and equal or high signal in T2-weighted images. Papillary and tubular types showed high signal in T1-weighted images, and low signal in T2-weighted images. In alveolar type, many cases showed equal echo in ultrasonography and hypervascularity in angiography, and in papillary and tubular types, many cases showed high echo and hypovascularity. There were many cases with ...
We present a case of cerebral aspergillosis in an immunocompetent patient. The MRI signal characteristics were compared with the histologic findings. Irregular low-signal zones were demonstrated between the wall of the abscess and the central necrosis on T2-weighted images; the pathology specimen revealed concentrated iron in these transitional zones but no hemosiderin. Iron is an essential element for the growth of fungal hyphae. The low-signal zones may represent the areas where there was active proliferation of aspergillus, and the unique location of the low signal may be a helpful imaging characteristic for the diagnosis of an aspergillus abscess. (orig.)
The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. ...
Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weighted images and decreased signal on T2-weighted images with no evidence of cystic degeneration. A group of 22 preterm infants with PWML at term PMA (PWML group) were compared with 22 matched controls ...
Background: Malformations of cortical development vary in neuronal maturity and level of functioning. Purpose: To characterize regional relative cerebral blood volume (rCBV) and difference in first moment transit time (TTfm) in polymicrogyria and cortical tubers using magnetic resonance (MR) perfusion imaging. Material and Methods: MR imaging and dynamic T2*-weighted MR perfusion imaging were performed in 13 patients with tuberous sclerosis complex, 10 with polymicrogyria, and 18 controls with developmental delay but no macroscopic brain abnormality. Regions of interest were placed in cortical tubers or polymicrogyric cortex and in the contralateral normal-appearing side in patients with malformations. In 'control' subjects, regions of interest were placed in the frontal and parietal lobes in both hemispheres. The rCBV and TTfm of the tuber/contralateral side (rCBVRTSC and TTFMTSC) as well as those of ...
The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent surgical procedures. One patient died of surgical complications. All other patients have been well without ...
To compare the accuracy of MR imaging using an endorectal-pelvic and a pelvic phased-array coil for preoperative local staging of rectal carcinoma. To determine preoperative staging, 38 patients with rectal carcinoma underwent MR imaging. All patients were examined with both an endorectal-pelvic and a pelvic phased-array coil. All underwent surgery and staging was pathologically confirmed. Two radiologists blinded to pathologic stage analyzed perirectal invasion and perirectal node metastasis, and scored according to a four-point scale. Radiologic and pathologic findings were correlated. Receiver operating characteristic (ROC) analysis of Wilcoxon statistic (W values) was used to compare diagnostic accuracy between the two different MR methods. Interobserver variation was measured using {kappa} statistics. For perirectal invasion, T1WI endorectal-pelvic phased-array coil images (reader 1:0. 854, reader 2:0.818) showed ...
The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. Margins were well defined in four out of the six patients. Four ...
Magnetic resonance (MR) imaging was performed in 26 patients with Ewing's sarcoma of bone preceding and following neoadjuvant chemotherapy, to assess tumour response non-invasively prior to surgery. T1- and T2-weighted spin echo images were obtained. Changes including intra- and extramedullary signal intensities, tumour demarcation, tumour volume and the appearance of residual extramedullary tumour were compared with histophathology of the resected specimens. Reduction of tumour volume was significantly higher in good responders. Other single parameters did not correlated with histologic tumour response. However, when several MR parameters summarized in a classification system were combined, a positive correlation with histopathologic response was found. A limited decrease of tumour volume (<25 %) and/or residual soft tissue mass following chemotherapy correlated with a poor response. An ...
Objective: To analyze the characteristics of external hydrocephalus in infancy with MR imaging, and to explore the cause of accumulation of extracerebral fluid and the relation with brain development. Methods: Conventional magnetic resonance T_1 weighted imaging (T_1WI) and T_2weighted imaging (T_2WI) were performed in 46 infants aged 2 years or younger with external hydrocephalus (EH), and the results were analyzed. They were divided into 7 age groups. The width of extractable space was measured on T_2WI and compared with normal standard. Results: EH mainly resulted from infection, subdural hematoma or subarachnoid hemorrhage, HIE, which were 67.4% (31/46 cases) of the cases; EH with unknown cause were 26.1% (12/46 cases). EH was mainly located at the foreside of cerebral convexity, of which 80.4% (37/46 cases )was predominantly in the subarachnoid space, 8.7% (4/46 cases) in subdural space, 10.9% was ...
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to focal involvement. Patients without ...
The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI (mean ?0.6 mm; standard deviation ?0.3 ...
Purpose: To evaluate a T_2-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T_2-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR_e_f_f/T_E/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of ...
Paroxysmal nocturnal hemoglobinuria (PNH) is a rare, acquired disease involving multiple hematopoietic cell lines. Characteristics of PNH are intrinsic hemolytic anemia, iron deficiency anemia and venous thrombosis. We report a case of PNH with characterostoc MR and CT findings. The signal intensity of renal cortex was lower than that of medulla on both T1-and T2-weighted MR imaging. On T2weighted MR images, the liver showed very low signal intensity but the signal intensity of the spleen was normal. On precontrast CT the attenuation of renal cortex was higher than that of renal medulla and the attenuation of liver was higher than that of the spleen. These findings of MR imaging and CT were the result from the deposition of hemosiderin in the cells of proximal convoluted tubules and transfusional hemosiderosis of liver.
Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...
This study was designed to evaluate early parenchymal changes of acute cerebral is chemia/infarct by using T2-weighted, diffusion-weighted, and calculated apparent diffusion coefficient(ADC) MR imaging. The brain MR images were successfully obtained 30, 60, 90, 120, 150 and 180 minutes after intraarterial administration of Lipiodol (0.4-0.6ml) into the common carotid artery in 10 of 11 cats (91%). T2-and diffusion-weighted images and ADC were analyzed and compared with histopathologic findings. High signal intensity on T2-weighted and diffusion-weighted images was found in one cerebral hemisphere 30 minutes after Lipiodol injection, which tended to increase with time until 3 hours. Subcortical white matter showed higher signal intensity than cortical gray matter since 30 minutes after embolization. ADC images showed decreased signal intensity in the embolized ...
To investigate the pattern of normal white-matter maturation as demonstrated by high-field-strength MR imaging, 82 normal infants were examined using a 1.5-T unit with spin-echo T1-weighted and T2-weighted pulse sequences. The infants ranged in age from 4 days to 2 years. The scans were assessed for qualitative changes of white matter relative to gray matter and correlated with the patient's age in 14 anatomic areas of the brain. The MR images showed that changes of brain maturation occur in an orderly manner, commencing in the brain stem and progressing to the cerebellum and the cerebrum. Changes from brain myelination were seen earlier on T1-weighted images than on T2-weighted images, possibly because of T1 shortening by the components of the developing myelin sheaths. The later changes on the ...
The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. ...
Six patients with eosinophilic granuloma were studied retrospectively in order to correlate the MRI appearances with the pathology. Ages ranged from 2 years 6 months to 11 years. The bones involved were the humerus, ulna, radius, femur, clavicle and ilium. Plain films, MRI and pathology specimens were obtained. A lytic lesion with indistinct margins, endosteal erosions and periosteal reaction was seen in all cases on plain radiographs. Bone marrow signal was decreased on T1-weighted images and increased on T2-weighted images throughout the bony lesion in all cases. T2-weighted images showed extensive soft-tissue abnormalities suggesting inflammatory changes in four cases. In two cases abnormalities were limited. Extensive changes correlated histologically with an early phase lesion. Localized minor changes were associated with a mid-phase lesion. Inflammatory ...
The MRI and CT appearances in 48 patients with histologically confirmed benign and malignant pleural abnormalities were compared retrospectively. Abnormal pleural changes were shown in 47 out of the 48 patients by high signal intensity of the pleura in T_2-weighted sequences and in contrast enhanced T_1-weighted sequences on MRI. CT showed abnormalities in 45 out of 48 patients. Delineation of pleural and pulmonary changes by CT was possible in 13 out of 23 cases, and pleural disease from effusions in 15 out of 28 cases. T_2-weighted MRI was successful in 14 out of 23 and 4 out of 28 cases, respectively. T_1-weighted images after contrast were successful in 20 out of 23 and 22 out of 28 cases, respectively. Indications of malignant pleural disease were the presence of mediastinal or circumferential involvement or involvement of the entire pleura, thickness of ...
Sixty-six cases of histologically proven hepatocellular carcinomas (HCC) were studied by MRI. Detectability was better by MRI than by CT, especially in the tumor under 2 cm in diameter. The capsule was detected in all cases of HCC over 3 cm in diameter. The capsule was able to be diagnosed only by dynamic MRI study in some cases. High intensity on the T1-weighted image and iso or low intensity on the T2-weighted image suggested that the nodule was adenomatous hyperplasi (AH) or well differentiated HCC. MRI is concluded to be an essential modality in the diagnosis of HCC. (author).
We report a 20-year-old woman who suffered headaches before presenting with a state of fluctuating vigilance. MRI showed diffuse high signal in the basal ganglia bilaterally on diffusion- and T2-weighted images, which had areas of both low and high apparent diffusion coefficient, presumed to correspond to cytotoxic and vasogenic oedema. MR venography showed no flow in the deep cerebral veins or straight sinus. Heparin was given, with clinical recovery. On follow-up MRI, the appearances became normal. (orig.)
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to ...
A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T_1- and T_2-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG).
MRI findings in 13 patients with monolateral parotid tumor were compared with US, sialographic and CT findings. MRI did not allow an accurate diagnosis in 2 patients with diffuse chronic parotitis. MRI was superior to CT in 1 case in defining the intraglandular site of the lesion, and in 2 patients in showing the extraglandular involvement. MRI proved to be superior to CT thanks to its contrast resolution and to multiplanar imaging. MRI high contrast resolution made it possible to demonstrate neoplastic lesions of 4 mm in diameter. The lesion has low signal intensity on T1-weighted images and high signal intensity on T2-weighted. Parotid tumors cannot be characterized by signal intensity alone: only morphology allows to discriminate between benign and malignant lesions. To conclude, US is a screening method, while MRI is helpful in detecting multifocal lesions and in evaluating the tumor extent.
We present two cases of fetal neck masses that were initially diagnosed by ultrasound and further evaluated with prenatal MRI. MRI findings aided in further delineating the neck masses, increasing confidence in the final diagnosis (cervical teratoma and cystic hygroma). With the fetal airway typically filled with fluid that is of high signal on T2-weighted sequences, MRI images in three planes could identify whether the fetal larynx and trachea were partially or completely compressed by the neck tumor. This information was particularly useful in determining if a controlled delivery such as ex utero intrapartum treatment (EXIT) was necessary and aided the surgeons in planning their approach to establishing airway control in the delivery room. (orig.)
We report the delayed sequelae arising in a case of electrical injury, reviewing the literature on the subject and focusing on the MRI findings of the brain. A 23-year-old male suffered burns to the left parietal scalp, both feet, and the anterior chest wall. Neurological symptoms and MRI abnormalities appeared 14 days after the insult and continued for about three months. T1-weight MR images demonstrated homogeneous hypointensity, while T2-weighted images depicted hyperintense finger-like projections. Contrast-enhanced T1-weighted images demonstrated strong band-like enhancement, indicating meningeal hyperemia. Follow-up MR imaging showed that the lesion had disappeared, indicating that the cerebral edema and meaningeal hyperemia were reversible.
In 15 patients (16 hip joints) we found the clinical and radiological signs of BMOS. On T1-weighted MRI images areas of low signal intensity could be observed in the head, neck and the intertrochanteric region of the femur in various extensions. These areas showed a significant increase in signal intensity on the T2-weighted images. Because pain was resistant to conservative therapy all these patients were treated by core decompression of the femoral head in a prospective study. Bone cores were evaluated histologically using undecalcified sections and quantitative microradiography. The existence of intramedullary oedema in exactly the regions exhibiting the MRI pattern of bone marrow oedema was verified histologically; however, bone and marrow changes similar to those of early avascular necrosis (AVN) were also visible. (orig.)
MAGNETIC FORMING .............. MAGNETIC INDUCTION ............ MAGNETIC MATERIALS ............ MAGNETIC MEASUREMENT .......... MAGNETIC PERMEABILITY . ...
60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A brilliant MR-tomographic imaging of the small bowel is possible under the condition, that the small bowel ...
To evaluate the yield of SPIR sequences with fat suppression in the diagnosis of optic nerve lesions. T1 and T2weighted fat suppressed SPIR imaging of the optic nerve improves anatomical definition, lesion detection and characterization in optic nerve conditions. [Italian] L'articolo analizza i vantaggi ricavabili dall'utilizzazione delle sequenze SPIR nella documentazione del decorso del nervo ottico e delle sue alterazioni nei pazienti con sospetto clinico e strumentale di malattia retrobulbare. L'utilizzo delle sequenze SPIR consente ottimale visualizzazione del nervo ottico e delle sue eventuali alterazioni senza gli artefatti che limitavano la qualita' delle immagini nelle prime sequenze RM con soppressione del segnale del grasso.
Intramuscular hermorrhage was induced by injecting autologous blood into the paraspinal muscle of 8 rabbits. In order to evaluate the time-dependent changes of hemorrhage observed on MRI, the animals were imaged at different stages of blood resolution at 0.02 tesla (T), and control examined with ultrasound using a 7.5 MHz linear transducer. Six inversion recovery sequences (TR=1 000 ms. TE=30 ms, and TI=18, 48, 148, 201, 302, and 398 ms) were used for the invivo calculation of T1 relaxation times. IR 1 000 (398)/30 imaging was performed before and after the Gd-DOTA administration. The hemorrhage was evident on MR images throughout the study, especially on the T2weighted (SE 1 000/100) images. MRI showed the healing lesion longer than ultrasound. The T1 relaxation time increased during the time of resolution. Lesions on days 4 to 7 enhanced in intensity after the injection of Gd-DOTA. (orig.).
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy ...
MR studies of 6 patients with intracranial tuberculoma are reviewed. All patients also underwent CT scans which showed hypo- or isodense lesions with abnormal enhancement following contrast administration. MR showed lesions with prolongation of the T1 relaxation time in every case. On the T2-weighted sequences, the signal properties of the tuberculoma varied according to the stage of evolution of the lesion. Incipient tuberculomas appeared as scattered areas of hypointensity surrounded by edema. Mature tuberculomas were composed of a dark necrotic center surrounded by an isointense capsule which was, in turn, surrounded by edema. In one patient, the center of the lesion was hyperintense probably because of liquefaction and pus formation (tuberculous abscess). While both, CT and MR, were equally sensitive in visualizing the intracranial tuberculoma in every patient, MR was slightly superior in demonstrating the extent of the ...
Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T_2-weighted spin echo (SE) images as well as T_1-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 meningiomas and 15 of 19 metastases without dural thickening at the ...
T_2weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering diagnostic ...
Problems and solutions in the diagnosis and operative treatment were clarified by retrospective evaluation of cases of intramedullary tumor in which MRI and surgery had been performed. The subjects were 16 patients (21-75 years old, mean age: 45 years) whose tumor was surgically removed between 1991 and 1998. MRI was performed preoperatively, and T1-weighted images, T2-weighted images, and enhanced images were obtained. Angiography was also performed in some cases. The histological diagnosis based on the MRI findings before surgery were compared with the pathological diagnosis after the operation. In 9/16 cases (56%), the preoperative histological diagnosis based on the MR images was the same as the pathological diagnosis after the operation. In 8 of the 11 cases (73%) whose images showed clear tumor margins and well shaped the tumor, the tumors were completely removed. The concordance rate between the pathological ...
This paper reports, to complement current knowledge on brain development, late regional brain maturation assessed with quantitative MR imaging. Axial and coronal head spin-echo (SE) images were obtained in 60 healthy individuals aged 5--56 years, with a double-echo, flow compensated imaging sequence obtained with a 1.5-T Magnetom spectroscopy and imaging system. T2-weighted images were calculated from the intensity differences in SE images at echo times (TEs) of 15 and 90 msec (TR = 2.5 second). The mean T2 values were determined at 16 sites in each cerebral hemisphere. T2 values of the six frontal subcortical white matter (FSCWM) sites and of the internal capsule (IC) were evaluated. Mean T2 values in the IC decreased until age 10 years, whereas this decrease continued in the FSCWM past age 15 years before reaching a plateau. Differential age-dependent patterns of mean T2 values emerged between the six FSCWM sites. The ...
Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced ...
Leukodystrophies are inherited white matter diseases due to abnormalities occurring in myelin synthesis and/or maintenance. The most common types of these rare childhood conditions are represented by adrenoleukodystrophy, metachromatic leukodystrophy, Canavan's, Alexander's, Krabbe's, and Pelizaeus-Merzbacher's diseases. Most of them are lethal during childhood, with the exception of the adrenoleukodystrophy-adrenomyeloneuropathy complex, which sometimes, during its early phases, may be cured with a dietary therapy. The aims of this paper are: 1) the description of inheritance factors, pathogenesis, pathological and clinical findings of each of the most frequent childhood leukodystrophies; 2) the description of the most common patterns of these conditions on CT and MR imaging; 3) the evaluation of the diagnostic capabilities of these two imaging techniques and the comparison of their results. Finally, some of the therapies suggested for the mild forms of these conditions are discussed. ...
The purpose of this study was to correlate MR imaging findings with pathology in experimental hyperoxia-induced acute lung injury, which has similar pathology to diffuse alveolar damage (DAD). Seventeen Yorkshire pigs were studied. These animals were exposed to more than 80% oxygen for 24, 48, 72, and 96 hours in a sealed cage. The lungs were removed and inflated with air infused through the trachea, and then examined by both MRI and high-resolution CT (HRCT). T1-weighted spin-echo (T1WSE), T2-weighted fast (T2WFSE), and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences were performed. Severity in MR findings and signal-to-noise ratios (SNR) on MR images were well correlated with pathological scores. CT values were also correlated well with pathologic scores. Abnormal SNR values were obtained from a pathological score of 5, whereas abnormal CT values were obtained from a pathological score of 15. ...
Lipiodol Ultra-Fluid (Lipiodol) is widely applied in the transcatheter arterial embolization (TAE). We studied signal intensity, the T1 relaxation time and the T2 relaxation time of Lipiodol itself using Siemens Magnetom H15-2 T (1.5 Tesla) and Magnetom M10 (1.0 Tesla). Lipiodol showed higher signal intensity than saline solution on the T1-weighted images (short TR, short TE technique in spin echo method). On the T2-weighted images (long TR, long TE technique in spin echo method), Lipiodol showed lower signal intensity than saline solution. The T1 relaxation time of Lipiodol, measured at 1.0 T, was 201 msec and 218 msec at 1.5 T. The T2 relaxation time of Lipiodol, measured at 1.0 T, was 127 msec; and 167 msec at 1.5 T. The signal intensity of Lipiodol at 1.0 T was higher than the intensity at 1.5 T. Shorter T1 relaxation time of Lipiodol at 1.0 T is probably responsible for the higher intensity at 1.0 T. When MRI is ...
Background. Metabolic disturbances such as anoxia and hypoglycaemia are important in causing maldevelopment of the neonatal brain. While there have been some pathology studies of the effects of neonatal hypoglycaemia on brain development, reports of MRI findings in such infants have been rare. Objectives. To describe the MRI findings in neurologically handicapped children who had suffered from neonatal hypoglycaemia and to evaluate the relationship between the neurological impairment and neonatal hypoglycaemia. Materials and methods. We retrospectively evaluated the MRI findings in eight full-term infants with neonatal symptomatic hypoglycaemia who later exhibited neurological handicap. The age at which the MRI scans were obtained ranged from 9 months to 8 years 10 months (mean 4 years 1 month, median 4 years). Results. The most striking findings were prolonged T1 weighting and T2weighting in the parieto-occipital ...
The purpose of this study is to investigate the role of femoral marrow MR imaging as predictor of outcome for hemopoietic stem cell transplantation (HSCT) in beta-thalassemia major. MR imaging of the proximal femur, including T1- and T2-weighted spin echo and short-tau inversion recovery and in-phase and out-of-phase fast field echo images, was prospectively performed in 27 thalassemia major patients being prepared for HSCT. The area of red marrow and its percentage of the proximal femur were measured, and the presence of marrow hemosiderosis was assessed. Age-adjusted multivariate logistic regression was used to determine the relationship between red marrow area percentage and marrow hemosiderosis and HSCT outcome. Red area percentage were less in patients with successful (90.25{+-}4.14%) compared to unsuccessful transplants (94.54% {+-}2.93%; p=0.01). Red marrow area percentage correlated positively with duration of ...
Diamagnetic samples placed in a strong magnetic field and a magnetic field gradient experience a magnetic force. Stable magnetic levitation occurs when the magnetic force exactly counter balances...Full Text Available
... Title : Refining the Magnetic Forming Capability. ... Abstract : The purpose of this project was to refine the in-house magnetic forming capability. ...
in pulse applications such as magnetic forming. ... In magnetic-forming electric circuitry, the ..... Aspects of Electrohydraulic land Magnetic Forming. ...
Primary malignant lymphoma of the brain is a disease of unknown etiology, which is increasing in incidence and has an unfavorable prognosis. Despite the lack of specific changes on CT or MRI in most cases, these procedures may typically facilitate the diagnosis: A focal-enhancing mass with subependymal spread on CT or MRI and hyperattenuation on nonenhanced CT are the most reliable features in the diagnosis of primary malignant lymphoma of the brain. Peritumoral edema and mass effect are usually not prominent features. On unenhanced CT scans they usually appear homogeneously isodense to mildly hyperdense relative to the gray matter. On MRI these tumors are slightly hypointense on T1-weighted images and slightly hpyerintense on PD- and T2-weighted images relative to the gray matter. On CT and MRI enhancement is usually homogeneous. Contrast-enhanced MRI, with its multiplanar capability, lack of bone-induced artifacts, and ...
60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A brilliant MR-tomographic imaging of the small bowel is possible under the condition, that the small bowel ...
In this review, we demonstrate the developmental appearance, structural features, and reorganization of transient cerebral zones and structures in the human fetal brain using a correlative histological and MRI analysis. The analysis of postmortem aldehyde-fixed specimens (age range: 10 postovulatory weeks to term) revealed that, at 10 postovulatory weeks, the cerebral wall already has a trilaminar appearance and consists of: (1) a ventricular zone of high cell-packing density; (2) an intermediate zone; (3) the cortical plate (in a stage of primary consolidation) with high MRI signal intensity. The anlage of the hippocampus is present as a prominent bulging in the thin limbic telencephalon. The early fetal telencephalon impar also contains the first commissural fibers and fornix bundles in the septal area. The ganglionic eminence is clearly visible as an expanded continuation of the proliferative ventricular zone. The basal ganglia showed an initial aggregation of cells. The most ...
The accurate staging of rectal carcinoma is very important for treatment planning. The histological data obtained from surgical specimens of 22 patients with rectal carcinoma were compared with pre-and postoperative endorectal US findings and with preoperative CT results. According to an adapted version of Astler and Coller classification, the different degrees of tumor spread into the rectal wall were represented as follows: stage A: 1 patient; stage B1: 5 patients; stage B2: 6 patients; stage C1: 1 patient; stage C2: 8 patients and stage D: 1 patient. Preoperative staging, based on the overall results of CT and US, was in agreement with histology in 19 of 22 cases. Individual analysis of US and CT results, in comparison with histological data, showed US staging accuracy to be 77.3% (17/22 patients). US accuracy in demonstrating tumor spread into the rectal wall (stages A, B1, C1) was 100% (7/7 patients); US was 70% accurate in lymph node detection (7/10 patients) ...
Magnetic separation of several classes of antibiotics was investigated using electrochemical magnetic seeding. Electrocoagulation with a sacrificial anode followed by addition of magnetite particles was applied for the magnetic seeding of antibiotics. With electrochemical magnetic seeding using an iron anode, tetracycline antibiotics (oxytetracycline, chlortetracycline, doxycycline and tetracycline) and cephalosporin antibiotic (cefdinir) were rapidly removed from synthetic wastewater by magnetic separation using a neodymium magnet. Iron and aluminium anodes were suitable for magnetic seeding of the antibiotics. The results indicated that the ability of antibiotics to form strong complex with iron and aluminium allowed the higher removal by magnetic separation. This method would be appropriate for rapid treatment of ...
This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet ...
We investigate the magnetic braking of the core of an axisymmetric cloud whose rotation axis is parallel to the mean direction of the magnetic field. (author).
Checks are performed on the alignment of the magnets in the LHC tunnel. It is vital that each magnet is placed exactly where it has been designed so that the path of the beam is precisely controlled.
The magnetic fluid is a colloidal suspension of magnetite in kerosene, prepared by a low-cost process. Separation is accomplished in an open trough filled with magnetic fluid. A magnetic field is established in the fluid, by energizing an electromagnet having poles on each side of the trough. Due to the design of the magnet poles and air gaps, the magnetic field is strongest at the bottom, about 10,000 oersteds, and uniformly decreases in strength to about 2000 oersteds at the top of the fluid. Therefore, the magnetic field gradient increases with depth. The magnetic force attracts the entire separation medium (magnetic fluid) creating a reaction force of equal magnitude and acting in the opposite direction. This reaction created within a magnetic fluid/magnetic field combination ...
Rare Earth Cobalt (REC) permanent magnets have unique properties that permit solutions to some optical tasks that cannot be accomplished with conventional magnets. A review of design and of performance characteristics of these magnets includes an analytical description of the three dimensional fringe fields of REC quadrupoles.
... in the design of such devices as fusion reactors, magnetohydrodynamic generators, magnetically levitated vehicles, magnetic forming devices, and ...
This paper traces the development and progress of magnetic suspension systems and magnetic bearings in the USSR. The paper describes magnetic bearings for turbomachines, magnetic suspension systems for vibration isolation, some special measuring devices, wind tunnels, and other applications. The design, principles of operation, and dynamic characteristics of the system are presented.
In order to examine the state of technology of all areas of magnetic suspension and to review related recent developments in sensors and controls approaches, superconducting magnet technology, and design/implementation practices, a symposium was held. The proceedings are presented. The sessions covered the areas of bearings, sensors and controls, microgravity and vibration isolation, superconductivity, manufacturing applications, wind tunnel magnetic suspension systems, magnetically levitated trains (MAGLEV), space applications, and large gap magnetic suspension systems.
Purpose: Cardiomyopathy is one of the major complications of {beta} thalassaemia major as a result of transfusion iron overload. The aim of our study is to evaluate with MR if there is any difference of iron deposition signal intensity (SI) or distribution between non-cardiopatic and cardiopatic thalassaemic patients in order to establish if there is a relationship between cardiopathy and iron deposition. Materials and methods: We studied 20 patients affected by {beta} thalassaemia major, of whom 10 cardiopatic and 10 non-cardiopatic, and 10 healthy volunteers as control group. Serum ferritin and left ventricular ejection fraction were calculated in thalassaemic patients. All patients were examinated using a 1.5 MR unit with ECG-gated GE cine-MR T2*-weighted, SE T1-weighted and GE T2*-weighted sequences. In all cases, using an adequate ROI, the myocardial and ...
A non-contact method, using magnetic drag force principle, was proposed to design the braking systems to improve the shortcomings of the conventional braking systems. The extensive literature detailing all aspects of the magnetic braking is briefly reviewed, however little of this refers specifically to upright magnetic braking system, which is useful for industries. One of the major issues to design upright magnetic system is to find out the magnetic flux. The changing magnetic flux induces eddy currents in the conductor. These currents dissipate energy in the conductor and generate drag force to slow down the motion. Therefore, a finite element model is developed to analyze the phenomena of magnetic flux density when air gap and materials of track are varied. The verification shows the predicted magnetic flux is within ...
Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)
To investigate the magnetic fluctuations and for further transport study, the poloidal and radial magnetic field measurement is conducted on the Sino United Spherical Tokamak (SUNIST). Auto-power spectral density indicates that the magnetic fluctuation energy mainly concentrates in the frequency region lower than 10 kHz. The magnetic field oscillations, which are characterized by harmonic frequencies of 40 kHz, are observed in the scrape-off layer; by contrast, in the plasma core, the magnetic fluctuations are of Gaussian type. The time-frequency profiles show that the poloidal magnetic fluctuations are temporally intermittent. The autocorrelation calculation indicates that the fluctuations in decorrelation time vary between the core and the edge. (authors)
Three-dimensional dynamics of a compact toroid (CT) plasmoid, which is injected into a magnetized target plasma region is investigated by using magnetohydrodynamic (MHD) numerical simulations. It is found that the process of the CT penetration into this region is much more complicated than what has been analyzed so far by using a conducting sphere (CS) model. The injected CT suffers from a tilting instability, which grows with the similar time scale as the CT penetration. The instability is accompanied by magnetic reconnection between the CT magnetic field and the target magnetic field, which disrupts the magnetic configuration of the CT. Magnetic reconnection plays a role to supply the high density plasma initially confined in the CT magnetic field into the target region. Also, the penetration depth of the CT high density plasma is ...
Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...
Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be ...
Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We ...
A number of interactions between magnetic fields and matter is reviewed. The resulting forces range in magnitude from the very large, obtained in high-energy fields, to the weak ones caused by the magnetostriction of ferromagnets. The fundamentals of these interactions are highlighted, and the examples discussed are forces on dipoles, particle alignment, magnetostrictive forces, magnetic forming, magnetic stirring, levitation melting, and magnetic pulsing of tool steels. (orig.)
A model is available in predicting flocculation frequencies between particles of various properties under the influence of a magnetic field. This model provides a basic understanding of fundamental phenomena, such as particle-particle and particle-collector interactions, occurring in HGMF (high gradient magnetic field), and will be extended to describe experimental data of particle flocculation and filtration and predict the performance of high- gradient magnetic filters. It is also expected that this model will eventually lead to a tool for design and optimization of magnetic filters for environmental, metallurgical, biochemical, and other applications.
Abstract in english We present a detailed derivation of the effective dielectric constant to be used in the dispersion relation for electrostatic waves in the case of a plasma immersed in a inhomogeneous magnetic field, with inhomogeneity perpendicular to the direction of the magnetic field.
A tutorial account is given of the main characteristics and distinctive features of conceptual magnetic fusion systems employing the magnetic mirror principle. These features are related to the potential advantages that mirror-based fusion systems may exhibit for the generation of economic fusion power.
An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.
An introduction to time-of-flight neutron spectroscopy is presented in the context of the study of magnetic materials. Examples are taken from the class of rare earth and actinide magnetic materials known as `strongly correlated electron` systems. (author) 11 figs., 24 refs.
The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...
The disclosure is directed to an active magnetic regenerator apparatus and method. Brayton, Stirling, Ericsson, and Carnot cycles and the like may be utilized in an active magnetic regenerator to provide efficient refrigeration over relatively large temperature ranges.
Parameters of permanent magnets result from the combination of intrinsic properties such as saturation magnetization, magnetic exchange, and magnetocrystalline energy, as well as microstructural parameters such as phase structure, grain size, and orientation. Reduction of grain size into nanocrystalline regime (#approx# 50 nm) leads to the enhanced remanence which derives from ferromagnetic exchange coupling between highly refined grains. In this study the fundamental phenomena, quantities, and structure parameters, which define nanophase permanent magnets are presented and discussed. The theoretical considerations are confronted with experimental data for nanocrystalline Sm-Fe-N type permanent magnets. (author)
Tumours lesions of the temporal bone and of the cerebello-pontine angle are rare.This tumours can be separated into benign and malignant lesions. In this paper the CT and MRI characteristica of tumours of the temporal bone and the cerebello-pontane angle will be demonstrated. High resolution CT (HRCT) as usually performed in the axial plane are using a high resolution bone window level setting, coronal planes are the reconstructed from the axial data set or will be obtained directly. With the MRI FLAIR sequence in the axial plane the whole brain will be scanned either to depict or exclude a tumour invasion into the brain. After this,T2-weighted fast spin echo sequences or fatsuppressed inversion recovery sequences in high resolution technique in the axial plane will be obtained from the temporal bone and axial T1-weighted spinecho sequences before and after the intravenous application of contrast material will be obtained ...
Principle advantages of magnetic forming for part manufacture appear to lie ... to be an area of great potential for the magnetic forming process. We have a ...
OBJECTIVE--The study was performed to examine the influence of the exposure to magnetic fields in the potrooms of an electrolysis plant on the occurrence of musculoskeletal symptoms among the employees....Full Text Available
Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented.
The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be ...
The ternary rare earth compound NdRh_4B_4 has been studied by means of critical field, low temperature heat capacity, and static magnetic susceptibility measurements. Features in the upper critical field and heat capacity data at 1.31 K and 0.89 K suggest the occurrence of long-range magnetic order in the superconducting state. The temperature dependence of the static magnetic susceptibility follows a Curie-Weiss law with an effective magnetic moment #mu#sub(eff) = 3.58 +- 0.05 #mu#sub(B) and a Curie-Weiss temperature thetasub(p) = -6.2 +- 1.0 K between 20 K and room temperature. However, magnetization vs. applied magnetic field isotherms suggest the development of a ferromagnetic component in the Nd"3"+ magnetization at low temperatures. (author).
Highly ordered arrays of Ni nanoholes and Fe{sub 20}Ni{sub 80} antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...
Highly ordered arrays of Ni nanoholes and Fe20Ni80 antidots have been prepared, respectively, by replica/antireplica processing and sputtering techniques using nanoporous alumina membranes as templates. Geometrical characteristics as nanohole/antidot diameter, interpore distance and the overall hexagonal symmetry of arrays are controlled through the original templates. Experimental data on their hysteresis and magnetic domain structure have been taken by vibrating sample magnetometry and magnetic force microscopy, respectively. An analysis of the magnetization process, resulting magnetic anisotropy and magnetic domain structure is summarized considering the influence of those geometry aspects. In particular, the hexagonal symmetry and the density of nanohole/antidots determine the overall magnetic behavior, which is of interest in future high-density ...
It is shown that plasma viscosity does not influence the magnetic island rotation directly. Nevertheless, it leads to nonstationarity of the plasma velocity. This nonstationarity is the reason of the viscosity effect on island rotation. (author)
... M(TH) in applied magnetic fields up to ± 7 T and for temperatures ranging from 2 to 300 K. The superparamagnetic (SPM) behavior of these metallic ...
Effective localization of small magnets against a noisy, real world background can involve various methods to first identify the magnetic fields produced by the magnet of interest, then to filter out background noise, and then to analyze the available magnetic field data to localize the magnet. Here we discuss low cost techniques which allow localization of small magnets with field strengths in the milliGauss range against real world background fields in the range of hundreds of mG, which may be fluctuating by up to tens of mG. Such techniques allow magnet tracking to be used to localize catheters in place of more invasive and expensive methods, e.g. fluoroscopy, for a variety of applications, including drug infusion with peripherally inserted central catheters (PICCs), laser ablation (TMR, PTMR) and introduction of pacemaker leads.
Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries
The dynamic response of cylindrical and ring-shaped YBaCuO bulk parts to pulsed magnetic fields is calculated by using small sets of finite elements. Some comparisons with experimental results are provided, and they give confidence in the modelling of the superconducting properties. Transient magnetizations as a function of time and space as well as shapes and absolute values of trapped magnetic flux profiles are presented. The influence of the sample geometry is investigated for different millisecond pulsed magnetization processes. Results are reported for different radial thicknesses and heights, different pulse durations, peak magnetic fields and pulse sequences with and without stepwise cooling. Comparisons concerning the achievable trapped magnetic field and flux are made, and implications for the use of high-temperature superconductor bulk parts as ...
A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in combating infectious GI ...
With the increased costs of maintaining boilers and chillers entrepreneurs around the country have offered magnetic and similar devices to facilities as viable alternatives to their maintenance program. This report gives a brief history of some of the pre...
... design, and manufacturing knowledge have been acquired and used to develop an 'in-house' capability for the fabrication of magnetic forming coils ...
has been generally related to magnetic forming. One of the methods suggested was the following: A "pancake" magnetic coil is placed over a thin aluminum ...
From optical point of view and due to the magnetic interaction of the cold neutrons with the unpaired electron shell, magnetic materials hae a neutron spin-dependent refractive index n[sup +] [spin up] and n[sup -] [spin down]. Magnetic media such as Fe, Co and Ni react like birefringent uniaxial crystals in ordinary optica. n[sup +] and n[sup -] are the equivalent of the ordinary and extraordinary refractive indices. The specular reflection of spin polarized neutrons which is due to the discontinuity of the magnetic induction at the surface of the ferromagnet is a sensitive probe of surface and interface magnetism. We shall first give the background of the art of polarized neutron optics. Secondly, some recent examples from surface and interface magnetism will be given to illustrate the power of this technique such as the magnetic coupling ...
For the purpose of solving the limitations such as shape and dimension for magnetic compact fabricated by conventional anisotropic forming under magnetic orienting field, the feasibility of a new magnetic forming process was studied. Ferrite powder mixed with UV resin was compacted in the die mold and followed by alignment under the magnetic field. Effects of viscosity of UV resin and forming condition on magnetic characteristics of the compact was investigated. Maximum degree of alignment for the ferrite powder reached to 0.826. It was predicted that the proposed method had make it possible to fabricate a high performance magnet having the anisotropic alignment of the magnetic powder. The UV resin is desirable to have low viscosity, good properties such as formability and configuration stability for the compact and also parting- ability ...
magnet research at several national laboratories through its Advanced Accelerator Technology Program. The HEP Conductor Development Program, a collaboration among national...
The magnetic properties of a single crystal of SmNiSn with the orthorhombic {epsilon}-TiNiSi-type crystal structure have been investigated by magnetic susceptibility, magnetization and electrical resistivity measurements from 1.5 K to room temperature. Two anomalies have been found in the magnetic susceptibility, indicating an antiferromagnetic phase transition at T{sub N}=9.4 K and a second transition at 4.4 K. A large magnetic anisotropy has been found at low temperatures in the temperature and field dependencies of magnetic susceptibility and magnetization. Below 80 K, the easy axis of the magnetization is the c-axis. At T=2.0 K, the c-axis magnetization curve exhibits metamagnetic-like behavior at H{sub c}=42 kOe and reaches 0.54 emu/g at H=55 kOe, whereas for the a- and b-axis the ...
A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting ...
180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector ...
Tests have recently been performed at Fermilab in order to measure the energy losses due to eddy currents and iron and superconductor magnetization. These measurements were performed on six 1.5m long model magnets and eight 15m long full scale collider dipole magnets. AC losses were measured as a function of ramp rate using sawtooth ramps from 500, to 5000 Amps for both types of magnets, while bipolar studies were additionally performed on some of the short magnets. The measured magnet voltage and current for a complete cycle are digitally integrated to yield the energy loss per cycle. Measurement reproducibility is typically 5%, with good agreement between long magnet measurements and extrapolations from short magnet measurement results. Magnetization loss measurements among similar ...
Three different magnetic regimes; aerial, surface and buried; each with three different forces, have been used to investigate their effects on the water contents and photosynthetic pigments of sweet basil plants (Ocimum basilicum L.). Two groups of sweet basil seeds, Ocimum basilicum L. have been cultivated, one under normal conditions and the second has been subdivided into three portion (aerial, surface and buried) to examine the effect of different magnetic forces coming from the three directions on the resulted plants. At all directions of magnets, water contents have been significantly affected by the magnetic forces. Chlorophyll A and carotene contents have been affected, as well, according to the three magnetic forces coming from soil surface regime only. Chlorophyll B did not significantly affected by differences magnetic forces in the three regimes, but ...
The effects of a moderate-intensity static magnetic field (SMF) on osteoporosis of the lumbar vertebrae were studied in ovariectomized rats. A small disc magnet (maximum magnetic flux density 180 mT)...Full Text Available
Using the full potential linearized augmented plane wave (FLAPW) method, thickness dependent magnetic anisotropy of ultrathin FeCo alloy films in the range of 1 monolayer (ML) to 5 ML coverage on Pd(0 0 1) surface has been explored. We have found that the FeCo alloy films have close to half metallic state and well-known surface enhancement in thin film magnetism is observed in Fe atom, whereas the Co has rather stable magnetic moment. However, the largest magnetic moment in Fe and Co is found at 1 ML thickness. Interestingly, it has been observed that the interface magnetic moments of Fe and Co are almost the same as those of surface elements. The similar trend exists in orbital magnetic moment. This indicates that the strong hybridization between interface FeCo alloy and Pd gives rise to the large magnetic moment. Theoretically calculated ...
In the present paper the progress of optimization of soft magnetic properties have been studied by applying different experimental techniques (magnetic measurements, electric measurements, X-ray analysis, and high-resolution electron microscopy observation). It has been shown that an increase in magnetic permeability after optimization annealing can be mainly attributed to annealing out of microvoids. (author)
Neutron scattering techniques have been used to measure the static structure and magnetic excitations in amorphous magnets. Sum rules and computer models are used to discuss the relationship between the static disorder and the shape of the excitation spectrum. Polarized beam measurements of chi''(Q,E) are compared to analytical theories and computer calculations for the magnetic excitations in amorphous ferromagnets.
The MOS-technology allows to make tiny electronic lenses for multibeam electron systems. In the paper results of research and principles of designing of tiny magnetic electron lenses are submitted. Electronic lenses with a nonconventional configuration of tiny magnetic circuit and electronic lenses with coincident electric and magnetic fields in nonconventional tiny performance are considered
The influence of rigid-body and differential rotation and of a fine-scale chaotic magnetic field and a poloidal magnetic field on the minimum mass of a main-sequence star is investigated. It is shown that rotation and a magnetic field with an energy equal to 10--20% of the star's gravitational energy increase the minimum mass of a main-sequence star by 1.5--2 times.
Helical dipole magnets are required in a project for the Relativistic Heavy Ion Collider (RHIC) to control and preserve the beam polarization in order to allow the collision of polarized proton beams. Specifications are for low current superconducting magnets with a 100 mm coil aperture and a 4 Tesla field in which the field rotates 360 degrees over a distance of 2.4 meters. A magnet meeting the requirements has been developed that uses a small diameter cable wound into helical grooves machined into a thick-walled aluminum cylinder.
The compound GdPd{sub 2}Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...
The compound GdPd_2Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition ...
This paper reports that only a few years ago superconducting magnetic separation was viewed as the next major market for superconducting magnets. The first commercial units had been installed, worked flawlessly, and demonstrated real economic viability. The potential market was seen as quite large, and many people believed that superconducting magnetic separation would soon show the same rapid growth that MRI had demonstrated after its initial success. These hopes even prompted IGC, one of the top MRI magnet builders, to form a separate division devoted to magnetic separation. Despite the existence of Magstream, IGC has not been overly active in the market. As a technology that has applications from the clay on the Earth to the soil on the moon, superconducting magnetic separation has yet to become widely used.
The characteristics of the local magnetic shear, a quantity associated with high-mode-number ballooning mode stability, are considered in heliotron/torsatron devices that have a large Shafranov shift. The local magnetic shear is shown to vanish even in the stellarator-like region in which the global magnetic shear is positive. The reason for this is that the degree of the local compression of the poloidal magnetic field on the outer side of the torus, which maintains the toroidal force balance, is reduced in the stellarator-like region of global magnetic shear because the global rotational transform in heliotron/torsatron systems is a radially increasing function. This vanishing of the local magnetic shear is a universal property in heliotron/torsatron systems with a large Shafranov shift since it results from toroidal force balance in the stellarator-like ...
We have analyzed the MHD flow of a conducting couple stress fluid in a slit channel with rhythmically contracting walls. In this analysis we are taking into account the induced magnetic field. Analytical expressions for the stream function, the magnetic force function, the axial pressure gradient, the axial induced magnetic field and the distribution of the current density across the channel are obtained using long wavelength approximation. The results for the pressure rise, the frictional force per wave length, the axial induced magnetic field and distribution of the current density across the channel have been computed numerically and the results were studied for various values of the physical parameters of interest, such as the couple stress parameter ?, the Hartmann number M, the magnetic Reynolds number R and the time averaged mean flow rate ?. Contour plots for the stream and ...
This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.
We compare experimental data for temperature dependence of the magnetic order parameter and the magnetic excitations (spin waves) in materials with a quenched orbital moment and a well-defined spin quantum number. It is observed that the thermal decrease of the two quantities proceeds according to the same analytical function of the type y(T)=1-cT"#epsilon# with an identical exponent #epsilon#. This power function applies not only asymptotically for T->0 but holds over a wide temperature range. The exponent #epsilon# is universal, i.e. independent of spin order type and lattice symmetry and depends only on the dimensionality of the relevant interactions and on whether the spin quantum number is integer or half-integer. The different T"#epsilon# functions are identified as representations of stable universality classes. The fact that order parameter and magnetic excitations follow the same T"#epsilon# function shows that ...
We describe a class of organic molecular magnets based on zwitterionic molecules (betaine derivatives) possessing donor, p bridge, and acceptor groups. Using extensive electronic structure calculations we show the electronic ground-state in these systems is magnetic. In addition, we show that the large energy differences computed for the various magnetic states indicate a high Neel temperature. The quantum mechanical nature of the magnetic properties originates from the conjugated p bridge (only p electrons) in cooperation with the molecular donor-acceptor character. The exchange interactions between electron spin are strong, local, and independent on the length of the p bridge.
We discuss how magnetic phenomena affect superconductivity in simple metals, transition metals and alloys thereof, and dilute Rare-Earth alloys. It is shown both qualitatively and quantitatively that superconductors are sensitive probes for studying itinerant spin excitations, local spin excitations associated with nearly magnetic impurities, the effect of the atomic environment on the stability of local magnetic moments, and the nature of the spin order in Rare-Earth alloys. Also, we discuss how magnetic impurities can be used to study the electronic configuration which is responsible for superconductivity in Laves-phase crystals like A-15 compounds and ..beta..-W crystals, for example.
The magnetization of ultrathin bcc Fe films (two and three monolayers) on MgO was measured and compared with the behavior predicted for a two-dimensional ferromagnet. The experiment indicated that no hysteresis was present in the magnetization. Instead, the magnetization at low temperature was affected by a marked field cooling effect. These observations lead to the conclusion that films of Fe on MgO of such thickness exhibit superparamagnetic behavior as if they were not entirely continuous. In contrast, films thicker than five monolayers exhibit a magnetic response close to that of bulk iron.
It has been carried out the magnetic properties determination for high iron oxide content glasses series obtained from a geothite red mud waste from the zinc hydrometallurgy and dolomite and glass cullet as main raw materials. It has been determined the magnetic susceptibility and magnetization values for the glasses here investigated. The results suggest that the magnetic behaviour are depending on the glass chemical composition, so that glasses can be differently classified like ferrimagnetic, ferromagnetic, superparamagnetic and paramagnetic. (Author) 6 refs.
Magnetic fluctuations present in the paramagnetic Mn{sub 0.81}Ni{sub 0.19} system have been investigated by measuring inelastic magnetic neutron scattering from a single crystal at temperatures of 450, 585 and 700 K. Antiferromagnetic correlations are observed to be present at all the temperatures studied. The spectral width of the magnetic scattering has been observed to increase with temperature, while the spatial range of the magnetic correlations is seen to decrease as the temperature is raised. The wave-vector-dependent susceptibility is found to follow a Curie-Weiss law near the (1 0 0) position, in agreement with theoretical predictions.
It is suggested that the magnetic Ap stars can be rotationally decelerated to long periods by the braking action of the associated magnetic field on time scales of order 10"7--10"1"0 years depending on whether the star's dipole field is aligned perpendicular or parallel to the rotation axis. Rotation includes a toroidal magnetic field in the plasma surrounding a star, and the accompanying magnetic stresses produce a net torque acting to despin the star. These results indicate that it is not necessary to postulate mass loss or mass accretion for this purely hydromagnetic braking effect.
The homogeneity of the magnetic field in the LHC dipoles strongly depends on the correct position of the superconducting cables: this is related to the quality of the dipole components, such as the dimension of the coil spacers (copper wedges), of the cable and of the collars. The performance in operational conditions is also affected by the magnetization of the cables. In this work, we analyse the measurements of these quantities during the production of the 1276 LHC dipoles, their trends, and the relation to the measured magnetic field. A novel mtehod to locate electrical shorts based on the analysis of magnetic measurements is also presented, and applications to 15 dipoles reascued during the production is given.
As low temperature cryocoolers become more frequently used to cool superconducting magnets, it becomes increasingly apparent that the connection between the cooler and the magnet has an effect on the design and performance of the magnet. In general, the use of small coolers can be considered in two different temperature ranges; (1) from 3.8 to 4.8 K for magnet fabricated with LTS conductor and (2) from 18 to 35 K for magnets fabricated using HTS conductor. In general, both temperature ranges call for the use of a two-stage cooler. The best method for connecting a cooler to the magnet depends on a number of factors. The factors include: (1) whether the cooler must be used to cool down the magnet from room temperature, (2) whether the magnet must have one or more reservoirs of liquid cryogen to keep the ...
Anisotropic Nd{endash}Fe{endash}B magnet powders can be produced by the hydrogenationdecomposition-desorption-recombination (HDDR) process from Nd{endash}Fe@ xnB{endash}Co{endash}M ({ital M}=Ga, Zr, Nb, Hf, and Ta) alloys. The present status of those HDDR powders and the bonded magnets made from them are reviewed with regards to the powder particle size dependence of their magnetic properties, their magnetic thermal stability, and their magnetization behavior. The results of a mechanistic study on the recombination step are also presented. The magnetic properties of the anisotropic HDDR powder depend relatively little on the powder particle size. Bonded magnets with a density of {approximately}6.20 g/cm{sup 3} and a BH{sub max} of 18.5{endash}20.5 MGOe can be produced from anisotropic HDDR powders with particle sizes of below 300 {mu}m diam. ...
Measurements of the magnetic susceptibility betweeen 0.03 and 300 K and of the magnetization between 0.05 and 10 K for magnetic fields up to 60kOe have been used to investigate effects from the interaction between the conduction electrons and local magnetic moments in (Lasub(1-x)Cesub(x))B_6 alloys (0.0007<=x<=0.10). For Ce concentrations x<0.006 the data show Kondo-type single impurity behaviour at low temperatures with a transition from a magnetic to a non-magnetic regime of the Ce ions. In the magnetic regime the impurity susceptibility follows a Curie-Weiss law, and in the non-magnetic regime it varies with T"2. An external magnetic field gradually restores the free-ion behaviour of the Ce impurities. For more concentrated alloys interactions between the impurities are observed. The RKKY ...
The magnetic separation technology using sub-microsized ferromagnetic particle is indispensable in many areas of medical biosciences. For example, ferromagnetic particles (200-500 nm) are widely used for cell sorting in stem cell research with the use of cell surface-specific antigens. Nanosized ferromagnetic particles (10-20 nm) have been suggested as more suitable in drug delivery studies given their efficiency of tissue penetration, however, the magnetic separation method for them has not been established. One of the major reasons is that magnetic force acting on the object particles decreases drastically as a particle diameter becomes small. In this study, magnetic force acting on the targets was enhanced by the combination of superconducting magnet and the filter consisting of ferromagnetic particle. By doing so, we confirmed that Fe{sub 3}O{sub 4} of 20 nm in diameter was ...
Magnetic drug targeting, using core-shell magnetic carrier particles loaded with anti-cancer drugs, is an emerging and significant method of cancer treatment. Gold shell-iron core nanoparticles (Fe@Au) were synthesized by the reverse micelle method with aqueous reactants, surfactant, co-surfactant and oil phase. XRD, XPS, TEM and magnetic property measurements were utilized to characterize these core-shell nanoparticles. Magnetic measurements showed that the particles were superparamagnetic at room temperature and that the saturation magnetization decreased with increasing gold concentration. The anti-cancer drug doxorubicin (DOX) was loaded onto these Fe@Au nanoparticle carriers and the drug release profiles showed that upto 25% of adsorbed drug was released in 80 h. It was found that the amine (-NH2) group of DOX binds to the gold shell. An in vitro apparatus simulating the human ...
With "1"5"1Eu-Moessbauer spectroscopy and other methods the complex magnetic properties of Eu_2PdSi_3, arising from the two crystallographically different lattice sites of the Eu"2"+ ions, have been already studied. Here we study the impact of magnetic dilution of the magnetic Eu"2"+ sites by non-magnetic Y"3"+ ions. A previous specific heat study has found reduced magnetic ordering temperatures with strong indication of disorder effects like in magnetic spin glasses. Here we provide from "1"5"1Eu-Moessbauer spectroscopy detailed information of the impact of Y"3"+ substitution on the magnetic properties of the two lattice sites, well distinguishable in the "1"5"1Eu-spectra. Since the substitution of the larger Eu"2"+ ions by the smaller Y"3"+ ions is connected with a lattice contraction, we also applied high pressure to the Eu_2PdSi_3 sample ...
The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd_2Si_2 have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd_2Si_2 is Curie-Wiess-like along the c axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.
The electrical resistivity, Hall effect, and magnetic susceptibility of single-crystal UPd[sub 2]Si[sub 2] have been studied between 4.2 and 300 K. A large anisotropy was observed in both the magnetic and transport properties. There is a quadratic temperature dependence of the resistivity for a range of temperatures between 4.2 and 80 K. At higher temperatures, the resistivity indicates a Kondo-type behavior. The behavior of these quantities is accounted for by the magnetic phase transitions at 108 and 136 K reported from neutron-scattering studies. At high temperatures, the magnetic susceptibility of UPd[sub 2]Si[sub 2] is Curie-Wiess-like along the [ital c] axis. The temperature dependence of the Hall coefficient above 108 K is accounted for by a theoretical model invoking skew scattering of conduction electrons by localized magnetic moments.
The Recycler ring magnet will be made of Strontium ferrite permanent magnets. A strontium ferrite permanent magnet without compensation has a temperature coefficient of -0.2 % in dB/dT. To compensate this effect, we are utilizing 30 % Ni 70 % Fe alloy, a temperature compensation ferromagnetic material with a low Curie point. To search for optimum commercially available material and optimum condition, we made a couple of simple model magnets, and tested with several different compensating material. The test results are reported and its optimal conditions are shown. Several different configurations were tested including a possible 2 kG magnet configuration.
We report on the magnetic hyperthermia properties of chemically synthesized ferromagnetic 11 and 16 nm Fe(0) nanoparticles of cubic shape displaying the saturation magnetization of bulk iron. The specific absorption rate measured on 16 nm nanocubes is 1690+-160 W/g at 300 kHz and 66 mT. This corresponds to specific losses-per-cycle of 5.6 mJ/g, largely exceeding the ones reported in other systems. A way to quantify the degree of optimization of any system with respect to hyperthermia applications is proposed. Applied here, this method shows that our nanoparticles are not fully optimized, probably due to the strong influence of magnetic interactions on their magnetic response. Once protected from oxidation and further optimized, such nano-objects could constitute efficient magnetic cores for biomedical applications requiring very large heating power.
The magnetic properties of polycrystalline and single crystalline rare earth transition metal silicides Gd_xLa_1_-_xMSi (M =Fe, Co) were investigated. Magnetic measurements have been made in static magnetic fields up to 13 kOe and in pulsed magnetic fields up to 250 kOe in the temperature range from 4.2 to 350 K. The magnetic susceptibility in the paramagnetic state of all the investigated compounds obeys the Curie-Weiss law except for LaFeSi and LaCoSi. Increase of the La content in Gd_xLa_1_-_xFeSi compounds leads to a decrease of the Curie and Neel temperatures, which can be explained by a decrease of positive exchange interactions. (orig.).
Sensitive and quick-response nonlinear inductance characteristics are found for high Tc superconducting (YBa/sub 2/Cu/sub 3/O/sub 7-chi/) disk cores at 77K in which soft magnetic BH hysteresis loops are observed. Various quick response magnetic devices such as modulators, amplifiers and sensors are built using these cores. The magnetizing frequency can be set to more than 20 MHz, which is difficult for conventional ferromagnetic bulk materials such as Permalloy amorphous alloys and ferrite. New quick-response fluxgate type magnetic-field sensors are made using ac and dc voltage sources. The former is used for second-harmonic type sensors, while the latter is for voltage-output multivibrator type sensors. Stable and quick-response sensor characteristics were obtained for two-core type multivibrators.
The Advanced Photon Source injector synchrotron is a 7-GeV positron machine with a standard alternating gradient lattice. The calculated effect of dipole magnet strength errors on the orbit distortion, simulated by Monte Carlo, was reduced by sorting pairs of magnets having the closest simulated measured strengths to reduce the driving the term of the integer resonance nearest the operating point. This method resulted in a factor of four average reduction in the rms orbit distortion when all 68 magnets were sorted at once. The simulated effect of magnet measurement experimental resolution was found to limit the actual improvement. The {Beta}-beat factors were similarly reduced by sorting the quadrupole magnets according to their gradients.
We investigated the magnet field dependence of the X-ray pulse height and the critical current of a Ti/Au bilayer TES micro-calorimeter. The pulse height was strongly affected by the magnetic field intensity applied perpendicularly to the TES surface. We found that the critical current at zero temperature, I c0, decreased by a factor of two by applying a magnet field of ?10??T. Our data are consistent with a TES sensitivity proportional to (I/I c0)?2/3, as predicted by the Ginzburg-Landau theory. This fact implies that the shape of the R?T curve of the TES is partly determined by the critical current of the superconductor. In order to make our TES microcalorimeters less sensitive to the external magnetic field, we fabricated devices equipped with on-chip magnetic shielding. One device has ...
The Large Hadron Collider (LHC) will be equipped with several thousands of superconducting corrector magnets. Among the largest ones are the superconducting trim quadrupoles (MQTL). These twin-aperture magnets with a total mass of up to 1700 kg have a nominal gradient of 129 T/m at 1.9 K and a magnetic length of 1.3 m. Sixty MQTL are required for the LHC, 36 operating at 1.9 K in and 24 operating at 4.5 K. The paper describes the design features, and reports the measured quench performance and magnetic field quality of the production magnets. The MQTL magnet production is shared between CERN and industry. This sharing is simplified due to the modular construction, common to all twin-aperture correctors.
Effect of low-frequency pulsating magnetic field on the microstructure and magnetic properties of amorphous alloy Fe_7_8Si_9B_1_3 were investigated. The temperature rise induced by the treatment was measured by a non-contact infrared thermometer. The crystallization behavior and microstructure of specimens were studied by Moessbauer spectroscopy and transmission electron microscope (TEM). Magnetic properties of the specimens were investigated by alternating gradient magnetometer (AGM). The results show that the low-frequency pulsating magnetic field can promote the single-phase crystallization of amorphous alloy Fe_7_8Si_9B_1_3. The frequency, f of applied field is from 10 to 40 Hz, magnetic field, H is from 0.02 to 0.04 T and treatment duration, t is from 180-300 s. The volume fraction of crystallization phase (#alpha#-Fe(Si), the grain size, 2-10 nm) is 3-7%. The temperature rise ...
This paper discusses the possible detection of magnetic monopoles and monopole tachyons. Topics considered include insects, astrophysics, general relativity theory, plants, and biotechnology. The paper was presented at an international symposium on non-conventional energy technology.
The investigated hybrid nanocomposite consists of a porous silicon template with electrochemically embedded Ni or Co nanostructures and offers magnetic characteristics which can be tailored by the electrochemical process parameters during fabrication. A twofold magnetic behaviour can be observed, a first one due to the spinmagnetism at magnetic fields below the saturation magnetization of the deposited metals and a second non-saturating term at higher fields (>1 T up to 7 T) above the saturation magnetization. In case of Ni deposited within the pores this non-saturating term shows a paramagnetic characteristic and follows exactly the Curie-Weiss law, whereas for Co/porous silicon samples the temperature dependent magnetization shows some deviations from the Curie Weiss law. In this high field region a difference in the temperature dependence between Ni ...
The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) heat leaks to various components of the TPC magnet cryogenics system besides the ...
A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.
BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available
The magnetic susceptibility and the density of human oxy-(HbO2) and carbonmonoxyhemoglobin (HbCO) solutions of various concentrations have been measured at room temperature, with pure water...Full Text Available
OBJECTIVES: This article uses meta-analysis methodology to examine the statistical consistency and importance of random variation among results of epidemiologic studies of residential magnetic field...Full Text Available
A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.
The magnetic properties of as-grown Ga1-xMnxAs have been investigated by the systematic temperature and magnetic field dependent soft x-ray magnetic circular dichroism (XMCD) measurements in the Mn L2,3 absorption edge region. The XMCD intensity at high temperatures obeys the Curie-Weiss law, but residual spin magnetic moment appears already around 100 K, significantly above Curie temperature (Tc), suggesting that short-range ferromagnetic correlations are developed significantly above Tc. The high-field magnetic susceptibility becomes T-independent below TC, indicating that the AF interaction between the substitutional Mn (Mnsub and interstitial Mn (Mnint) ions, which becomes strong as the Mn concentration x increases, exists and that the amount of the Mnint affects Tc. The present experimental findings should give valuable insight into the inhomogeneous ...
OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available
An in-plane uniaxial magnetic anisotropy has been observed in thin Co films normally deposited onto obliquely sputtered Ta and Pt underlayers. Associated with this anisotropy is an augmented easy axis coercivity. The in-plane easy axis is, in most cases, perpendicular to the incident deposition plane. Microstructural results indicate that grains are well connected along the magnetic easy axis but are separated by long continuous voids along the hard axis, which is ascribed to a geometric shadowing effect due to the oblique incidence deposition of the underlayer. Hence, the magnetic anisotropy mimics the film growth anisotropy. It is therefore believed that the observed magnetic properties are due to magnetostatic shape anisotropy effects. In-plane coercivity and anisotropy field are shown to increase with underlayer deposition angle, underlayer thickness and magnetic layer ...
A considerable amount of chemical knowledge of marine sediments has been acquired in recent years but has not yet been utilized by paleomagnetists. On the other hand, geochemists are often unaware of the usefulness of numerous magnetic techniques. In this review we try to bridge this gap, and in particular, we outline many of the chemical and magnetic principles that should allow paleomagnetists to better identify and undertand chemical changes that affect the magnetic properties of marine sediments. The chemical principles include those for distinguishing the four major sources of sediments (continental, biological, authigenic/hydrogenous, volcanic/hydrothermal) from one another by determining elemental abundance distributions, as well as for investigating the stabilities of mineral phases relative to changes in pE and pH. The magnetic principles include the effects of authigenesis and diagenesis on ...
ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available
Major breakthroughs have recently been reported that can help overcome two inherent drawbacks of NMR: the lack of sensitivity and the limited memory of longitudinal magnetization. Dynamic nuclear polarization...Full Text Available
Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available
OBJECTIVES: To appraise epidemiological evidence of the purported association between residential exposure to power frequency magnetic fields and adult cancers. METHODS: Literature review and epidemiological...Full Text Available
Epidemiologic research concerning electric and magnetic fields in relation to cancer has focused on the potential etiologic roles of residential exposure on childhood cancer and occupational exposure...Full Text Available
Naturally occurring and contaminant ferromagnetic and ferrimagnetic particles have been found within or near cells, and might allow pulsed magnetic fields to create transient cell membrane opening ("pores")....Full Text Available
The purpose of this study was to assess the effect of a 735-kV transmission line on the electric and magnetic field exposures of people living at the edge of the line's right of way. Exposure of 18...Full Text Available
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
A design of the modular coil system for CHS-qa has been made for the plasma configuration '2b32' with the aspect ratio 3.2. The magnetic field strength and the major radius are 1.5 T and 1.5 m, respectively. The normal component of magnetic field produced by the modular coils is minimized on the plasma boundary to obtain the optimum coil design. We put engineering constraint on the distance between adjacent modular coils and the radius of coil curvature. The dependence of the residual normal component of the field on these conditions is examined, and the realistic values for them are selected. Additional coils to control various properties of the magnetic field configuration (the rotational transform, the magnetic well depth, etc.) have been designed and a flexibility of the magnetic field configuration is realized. For the case that the rotational transform ...
The magnetically controlled plasma opening switch (MCPOS) is an advanced plasma opening switch that utilizes magnetic fields to improve operation. Magnetic fields always dominate terawatt, pulsed power plasma opening switches. For that reason, the MCPOS uses controlled applied magnetic fields with magnitude comparable to the self-magnetic field of the storage inductor. One applied field holds the plasma in place while energy accumulates in the storage inductor, then another applied field pushes the plasma away from the cathode to allow energy to flow downstream. Over a ten month period, an MCPOS was designed, built, and tested on DECADE Module 2 at Physics International. The peak drive current was 1.8 MA in 250 ns. The output parameters were up to 1 MA into an electron beam load. The radiation temporal pulse width averaged 60 nanoseconds full-width at half-maximum. The peak load ...
A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available
OBJECTIVES--This case cohort study examines whether there is an association between exposure to electric and magnetic fields and suicide in a population of 21,744 male electrical utility workers from...Full Text Available
Name U.S. Geological Survey A Helicopter-Borne Magnetic Survey over Dixie Valley Geothermal Field, Nevada: A Web Site for Distribution of Data by U. S. Geological Survey &...
A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.
... The Effect of the Temperature to Which the Material is Heated on the Process of Formation of Intermetallic Compounds in Magnetic Pulse Welding,. ...
The read/write characteristics for perpendicular magnetic recording media of focused-ion-beam (FIB)-etched recording heads were investigated. It was found that the trailing edge of an FIB-etched head produces a higher gradient in the magnetic field perpendicular to the medium than a head which has not been etched. The signal-to-noise ratio of the medium increased with the FIB-etched write gap. A high-Bs and thin pole increased the magnetic field's gradient in the perpendicular direction, resulting in excellent read/write characteristics.
It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)
XVTa and XXTa nuclei were oriented at low temperature as dilute impurities in Fe. The magnetic hyperfine splitting frequencies = B sub(HF)/Ih of the XVTa and XXTa ground states have been measured to be 320.45(11) and 317.552(55) MHz by using the technique of NMR-ON. Taking the known hyperfine field of Y Ta in Fe, the magnetic moments have been deduced: ( XVTa, 7/2 ) =2.270(45) and ( XXTa, 7/2 ) =2.250(45) sub(N). These values of the magnetic moments are discussed in the framework of the rotational model.
The paramagnetic susceptibility of single crystals of dysprosium-yttirum alloys is measured in the basal plane and along the hexagonal axis. It is shown that the susceptibility of the alloys obeys the Curie-Weiss law, the effective magnetic moments allong the different directions being the same and the paramagnetic Curie temperatures being different. The difference between the paramagnetic Curie temperatures in the basal plane and along the hexagonal axis is independent of the dysprosium concentration in the alloy. As a comparison with the theoretical models of magnetic anisotropy shows, this is an indication that the magnetic anisotropy of dysprosium - yttrium alloys is of a single-ion nature.
A method to achieve NMR of dilute samples in the earth's magnetic field by applying para-hydrogen induced polarization is presented. Maximum achievable polarization enhancements were calculated by numerically simulating the experiment and compared to the experimental results and to the thermal equilibrium in the earth's magnetic field. Simultaneous 19F and 1H NMR detection on a sub-milliliter sample of a fluorinated alkyne at millimolar concentration (1018 nuclear spins) was realized with just one single scan. A highly resolved spectrum with a signal/noise ratio higher than 50:1 was obtained without using an auxiliary magnet or any form of radio frequency shielding.
This review of methods and designs of transducers for nondestructive determination of the magnitude and nature of the anisotropy of magnetic properties (permeability, induction, coercive force, energy loss due to magnetization reversal) in local portions of ferromagnetic sheet and, in some cases, in individual parts of products. The need to measure the anisotropy is considered for two angles: for the case when the anisotropy is due to the crystallographic texture and determines the main operating characteristics of widely used sheet such as electrical steel and automobile body sheet, and for crystallographically isotropic materials, in which the anisotropy of magnetic properties as a result of mechanical stresses is a measure for determining the internal stresses.
The magnetic structure of a tetragonal Ce(Ru_0_._9_6Pd_0_._0_4)_2Si_2 single crystal, determined by neutron diffraction measurements, is similar to that observed in Rh doped alloys. The magnetic moments are oriented and modulated along the c-axis. Here the wave vector is incommensurate: k=(0,0,0.38). At 1.5 K, the moment is estimated to about 0.3 #mu#_B. Magnetization, magnetoresistance and Hall effect measurements performed on this alloy are also reported. (orig.).
The a.c. susceptibility and high field magnetization of TbRh{sub 2-x}Pd{sub x}Si{sub 2} and TbRu{sub 2-x}Pd{sub x}Si{sub 2} compounds were investigated up to 140 kOe. The (T, x) magnetic phase diagrams were determined. For both systems, an increase in the Pd content causes a decrease in the Neel temperature and changes the magnetization curves. (orig.)
The combined magnetic braking-ambipolar diffusion problem in weakly ionized, rigidly rotating disks is studied. An analytical solution is presented for a disk whose angular velocity and magnetic yield vectors are aligned with the symmetry axis, illustrating the effects of the relative azimuthal drift of neutrals and ions. The effects of radial drift are added, commenting on the ratio of the characteristic ambipolar diffusion and magnetic braking time scales in high-mass and low-mass disks. A numerical calculation is used to show the combined action of these two processes. 31 references.
The effect of elastic and plastic strains on the magnetic properties of ferrite-pearlite steels has been studied. It has been shown that the sensitivity to elastic-tensile and bending strains is four to five times greater for remnant magnetization than for coercive force. In order to determine the degree of cold plastic deformation of high-carbon steels, a two-parametric testing technique based on the use of remnant magnetization and coercive force was suggested. An MMT-2 device was recommended for measurement of the required parameters.
The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).
An accelerator has limited dynamic range: a chain of accelerators is required to reach high energy. A combination of septa and kicker magnets is frequently used to inject and extract beam from each stage. The kicker magnets typically produce rectangular field pulses with fast rise- and/or fall-times, however the field strength is relatively low. To compensate for their relatively low field strength, the kicker magnets are generally combined with electromagnetic septa. The septa provide relatively strong field strength but are either DC or slow pulsed. This paper discusses injection and extraction systems with particular emphasis on the hardware required for the septa.
The magnetoresistance in an FeNi submicron-structure comprising two wires of 80 and 200 nm in width connected in series was measured at 77 K. When the external magnetic field was applied parallel to the wire axis, two switching fields corresponding to the distinct coercive force of the two wires were observed. When the external magnetic field was applied at an angle of {theta}>30 deg. to the wire axis one switching field was observed, indicating simultaneous magnetization reversal in both wires. This indicates that the domain-wall trapping around the joint can be controlled systematically in terms of the direction of the external magnetic field.
The authors have performed a preliminary design for a persistent GHz NMR magnet at 23.5 T and 1.8 K operating conditions. In this paper the authors shall address the issues of realistic conductor selection, the coil design, the magnetic and mechanical analysis of the coil, and the required field uniformity. In addition, they shall describe the GHz magnet cryostat with a practical 1.8 K J-T refrigerator system. Finally vibration isolation system and field shield design and its associated field harmonics will be analyzed.
... fields, materials can be subjected to energy densities exceeding those realized in high explosives, a fact which forms the basis for magnetic forming ...
The results of the investigations show that magnetic treatment is a quite practical and effective method of intensifying certain technological processes in the coking industry. Magnetic treatment was utilized for improving the production of ammonium sulfate, refining of the naphthalene fraction, removal of sludge from wash oil in the benzol division, and the treatment of tar before fractionation. 2 references, 3 tables.
The concept of the minimum propagating zone (MPZ) is used to examine the causes of quenches in ISABELLE cosine theta superconducting dipole magnets. The size of disturbances large enough to exceed the MPZ and initiate quenches is estimated and compared with the size of disturbances which may be produced in the magnets. A suggestion for reducing the size of these disturbances through individual support of the coil block is outlined.
The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.
High-spin states in {sup 202}Pb and {sup 203}Pb have been investigated by in-beam {gamma}-ray spectroscopy following the reaction {sup 198}Pt({sup 9}Be,xn). A search for magnetic rotational bands in these isotopes confirmed one of the two bands previously assigned to {sup 202}Pb and revealed a new band in this isotope. No evidence for magnetic rotation has been found in {sup 203}Pb. (orig.)
Plasma confinement by permanent magnets has been studied. An analytic formula for the field of a single bar magnet has been obtained. Generalization to various configurations of multidipole fields has also been found. Any two-dimensional field may now be completely described by a simple function of complex variables in closed form. Vector potential has also been obtained by integrating over a prescribed Riemann surface. The confinement of plasma by multidipole fields then becomes obvious through conservation principles.
Due to biological effects of magnetic fields of high voltage transmission lines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmission lines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmission lines and the results are analyzed.
An alternative and graphical representation of the magnetic moment and the effective paramagnetic moment for polycrystalline Ce compounds with tetragonal site symmetry is described. The reduced moments can be calculated by means of standard perturbation theory. The calculated values deduced from the ground states of CeCu_2Si_2, CeRu_2Si_2, and CePd_2Si_2 polycrystals are compared with experimental magnetic moments.
Measurement of the magnetic susceptibility of powder samples of heavy rare-earth (Tb, Dy, Ho, Er, Tm and Yb) tungstates have been reported in the temperature range 300 to 900 K. Curie-Weiss law behaviour has been observed for all samples. The Curie constant, paramagnetic Curie temperature and magneton number for the magnetic ions have also been evaluated for each material. (author).
Results of experimental researches of impurity level crystals Fe1-xCoxSi are presented in this article. Magnetic properties in a temperature range up to T {<=} 1000 K are analyzed. It was established that with Co impurities increasing origin of magnetic ordering exists at low temperatures. At high temperatures a high temperature maximum of susceptibility of nominally pure iron monosilicide crystal is observed.
This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.
We report on solid solution CePd_2_-_xMn_xSi_2 which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.)).
We report on solid solution CePd[sub 2-x]Mn[sub x]Si[sub 2] which shows an interesting transition of the Ce-ion from magnetism in a Kondo regime to an intermediate valence state coupled with a strongly magnetic 3d sublattice. ((orig.))
Calculating the local spectral densities at magnetic adatoms, we estimate the variation in the Yosida-Kondo resonance due to the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction and the direct exchange between adatoms in systems of magnetic trimers on metal surfaces. The results show that the RKKY interaction leads to the gradual variation in Kondo temperature, and the direct exchange can be the origin of the drastic variation. (author)
The gauge-invariant correlation function for the Yang-Mills field strengths is shown to admit a symmetric decomposition into electric and magnetic components. The spectral weights are seen to obey a sum rule of the superconvergence type, owing to asymptotic freedom. The close relation between the dielectric function, electric-magnetic duality, and the algebra of generalized Chern-Simons charges is illustrated for the linearized Yang-Mills-Higgs system.
The purpose of this paper is to demonstrate how recent experimental results of "1"5"1Eu and "5"7Fe high pressure Moessbauer studies in 4f and 3d metallic magnetic systems can contribute to a deeper understanding of the nature of local moment (4f) and itinerant (3d) magnetism in these systems. Special emphasis is given on the comparison of the experimental results with related theoretical models. (orig.).
Ferrofluids have promising potential for heat transfer applications, since advective transport in a ferrofluid can be readily controlled by using an external magnetic field. However, unlike conventional free or forced convection, ferrohydrodynamic convection is not yet well characterized. A full understanding of the relationship between an imposed magnetic field, the resulting ferrofluid flow, and the temperature distribution is a prerequisite for the proper design and implementation of applications involving thermomagnetic convection. The literature variously assumes constant magnetic fields, does not completely represent the variation in the imposed field, or its descriptions are inaccurate, since the fields do not comply with the Maxwell's equations of electromagnetism. We address this by simulating two-dimensional forced convection heat transfer in a channel with a ferrofluid that is under the influence of a ...
Ferrofluids have promising potential for heat transfer applications, since advective transport in a ferrofluid can be readily controlled by using an external magnetic field. However, unlike conventional free or forced convection, ferrohydrodynamic convection is not yet well characterized. A full understanding of the relationship between an imposed magnetic field, the resulting ferrofluid flow, and the temperature distribution is a prerequisite for the proper design and implementation of applications involving thermomagnetic convection. The literature variously assumes constant magnetic fields, does not completely represent the variation in the imposed field, or its descriptions are inaccurate, since the fields do not comply with the Maxwell's equations of electromagnetism. We address this by simulating two-dimensional forced convection heat transfer in a channel with a ferrofluid that is under the influence of a ...
In this letter we report a clear and unambiguous observation of the out-of-plane quadrupole magnetic field suggested by numerical simulations in the reconnecting current sheet in the Magnetic Reconnection Experiment (MRX). Measurements show that the Hall effect is large in collisionless regime and becomes small as the collisionality increases, indicating that the Hall effect plays an important role in collisionless reconnection.
Annealing of magnetostrictive Metglas foils, subsequently incorporated into laminated Metglas/Pb(Zr, Ti)O3 magnetoelectric (ME) composites, is shown to result in improved magnetic properties, as well as ME coefficients. Annealing of the foils at 350 ?C resulted in partial crystallization, without oxidation or magnetic cluster formation that would reduce the magnetization. Laminate composites made with these annealed Metglas foils had improved ME coefficients.
It is shown that recuperator in which the thermal energy of particles is transformed into electric oue under drift in crossed fields is naturally coupled with dragontype magnetic confinement system, so the recuperation process can be initiated in the dragon magnetic field. A number of questions occuring under analysis of recuperator-dragon system is considered, including the dynamics of particle transfer to the recuperator, the share of particles entering the recuperator, the effect of rotational transform and the recuperation efficiency.
Some applications of magnetic resonance in coal liquefaction research described briefly are: (1) investigation of the nature of carbon deposits on used coal-liquefaction catalysts, (2) determination of the fate of hydrogen during coal liquefaction, and (3) observation of transient free radicals during coal pyrolysis. The first two applications make use of cross-polarization /sup 13/C magnetic resonance combined with magic angle spinning, and the third application is an electron spin resonance study. (BLM)
The conductance in ferromagnetic Ni nano-wire is quantized in units of 2e{sup 2}/h in the absence of magnetic field, while the units switch to e{sup 2}/h in the magnetic field. The fractional units of 0.7e{sup 2}/h and 1.4e{sup 2}/h with and without magnetic field appear under the application of high bias-voltage. The spin polarization and bias-voltage play an important role in the electric conduction.
Here, we consider a recent paper concerned with magnetic braking by induced currents (Ireson and Twidle 2008 Eur. J. Phys. 29 745-51). Our objective is to elucidate why measurement of speed in which a magnet is dropped through a non-ferromagnetic conductive tube depends on its geometry in a non-monotonic way, which was not clearly explained by the authors. (letters and comments)
Although a large number of studies on effects of magnetic fields on living organisms was reported, no definite results were obtained in many cases because the related conditions are non-uniform and uncertain, such that the uniform magnetic space is smaller than test samples, and temperature control is insufficient. Therefore, the present study developed a microorganism cultivation system that is applied with a 7-T superconducting magnet. This system has the following features: it generates homogeneous magnetic fields of 0.5 to 7 T {plus_minus} 0.5% in the space with a diameter of 100 mm and a length of 200 mm in a normal temperature bore (with a diameter of 160 mm); it can cultivate microorganisms aerobically at temperatures of 10 to 70{degree}C {plus_minus} 0.1{degree}C; it can perform the cultivation simultaneously with a control cultivation in a small magnetic field weaker than ...
We present a formulation of ab initio electronic structure calculations in a finite magnetic field, which retains the simplicity and efficiency of techniques widely used in first principles molecular dynamics simulations, based on plane-wave basis sets and Fourier transforms. In addition we discuss results obtained with this method for the energy spectrum of interacting electrons in quantum wells, and for the electronic properties of dense fluid deuterium in a uniform magnetic field.
A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).
A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).
Recent advances in nanoscience have raised interest in the minimum bit size required for classical information storage. This bit size is determined by the necessity for bistability with suppressed quantum tunnelling and energy barriers that exceed ambient temperatures. In the case of magnetic information storage, much attention has centred on molecular magnets with bits consisting of about 100 atoms, magnetic uniaxial anisotropy energy barriers of about 50?K and very slow relaxation at low temperatures. Here, we draw attention to the remarkable magnetic properties of some transition-metal dimers, which have energy barriers approaching 500?K with only two atoms. The spin dynamics of these ultrasmall nanomagnets is strongly affected by a Berry phase, which arises from quasi-degen...
The mapping of the magnetic flux bundle from the center cell to the Plasma Potential Control plates (PPC) on the end fan of the Tandem Mirror Experiment Upgrade (TMX-U), was improved by the addition of trim coils (12,000 amp-turns) on each side of each end fan next to the pump beam magnetic shields. The coils' axes are oriented perpendicular to the machine centerline. These coils made the necessary corrections to the field-line mapping, while keeping the field in the nearby pump beam magnetic shield below the saturation threshold. This paper briefly describes the problem, discusses the design as it evolved, and presents the results of the field testing. A brief description of the improvement in the machine performance is also included.
Monte Carlo calculations of proton irradiation of permanent magnets for the TRADE experiment have been performed. An irradiation dose of about 4´106 Gy/yr/mA has been estimated due to beam losses in normal operating conditions. Existing experimental results indicate that this irradiation level may induce a considerable demagnetization: in fact, a dose of 6´107 Gy induces a remanence loss of 0.3 % on samples of Sm2Co17 magnets, which are the most resistant type. More detailed calculations with the final design of the magnets and of the beam line are suggested, to determine if the irradiation levels allowed a reliable operation of the permanent magnets for the entire duration of the TRADE experiment. Damage and gas production rates have also been calculated; the values obtained are very low, thus confirming that the demagnetization process is in great part reversible.
Nanocrystalline MnFe"2O"4 ferrite was prepared by using autocombustion technique (flash). The microstructure and magnetic properties are studied. The results of XRD and TEM clarified that, this ferrite is nanosized with particle size (39 nm). Magnetic measurements showed a ferromagnetic behavior with T"C = 613 K, the saturation magnetization M"s = 13.71 emu/g, remanent magnetization M"r = 0.1694 emu/g and, coercivity H"c = 25.6 Oe. Natural material, egg white used as an aqueous medium to extend prepare nanoparticles better than other chemical interesting materials.
Magnetic refrigeration uses the temperature- and field-dependence of the entropy of some magnetic materials to accomplish cooling. Because of the intrinsically high efficiency of the magnetization and demagnetization process and because of the potential for excellent heat transfer between solids and fluids, magnetic refrigerators promise to have higher efficiency than existing gas-cycle refrigerators. Many ground-based and space-based applications could benefit significantly from the cost savings implied by higher efficiency. Other attributes of these devices are high reliability and low volume and mass per unit cooling power. The development of these refrigerators is underway at several places around the world, including the Los Alamos National Laboratory. The progress to date has been encouraging but some problems have been clearly identified. The arguments for high efficiency and the problems that ...
Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is ...
We derive the exchange currents of pseudoscalar, vector, and scalar mesons from Feynman diagrams, and use them to calculate the magnetic form factors of nucleon and ?(1232). The magnetic moments and electromagnetic radii are obtained by using those form factors and the parameters determined from the masses of nucleon and ?(1232). We find the magnetic moments and electromagnetic radii of nucleon and ?(1232) can be produced very well in the extended Goldstone-Boson-exchange model in which all of pseudoscalar, vector, and scalar meson nonet are included. The magnetic moments of ?(1232) are closer to experiment values and results from lattice calculation than the results obtained by the model without other mesons except for pion and sigma.
The switching behavior of magnetic patterns prepared by ion irradiation was investigated. Co/Pt multilayers with perpendicular anisotropy and large out-of-plane coercivities 5-6 kOe were grown on electron transparent SiN windows. Regularly spaced 1 micron sized regions, were magnetically pattered via ion beam irradiation through a stencil mask. Lorentz TEM was used to observe in-situ magnetization reversal processes of irradiated regions under well-defined applied magnetic fields. When the in-plane field was increased, domain wall motion was observed, resulting in the alignment of the patterns with the direction of the applied field. The switching mechanism of the in-plane patterns was by domain wall motion.
RHIC 8 cm aperture dipole magnets and quadrupole cold masses are being built for Brookhaven National Laboratory (BNL) by Northrop Grumman Corporation at a production rate of one dipole magnet and two quadrupole cold masses per day. This work was preceded by a lengthy Technology Transfer effort which is described elsewhere. This paper describes the tooling which is being used for the construction effort, the production operations at each workstation, and also the use of trend plots of critical construction parameters as a tool for monitoring performance in production. A report on the improvements to production labor since the start of the programs is also provided. The magnet and cold mass designs, and magnetic test results are described in more detail in a separate paper.
This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower Saxony. (Uhe).
The Superconducting Super Collider uses approx. =9600 dipole magnets. The magnets have been carefully designed to exhibit minimal magnetic field harmonics. However, because of superconductor magnetization effects, iron saturation and conductor/coil positioning errors, certain harmonic errors are possible and must be corrected by use of multipole correctors called trim coils. For the most efficient use of axial space in the magnet, and lowest possible current, a distributed internal correction coil design is planned. The trim coil assembly is secured to the beam tube, a uhv tube with special strength, size, conductivity and vacuum. The report details the SSC trim coil/beam tube assembly specifications, history, and ongoing development.
The magnetic three spin-1/2 model for nanometer-scale molecular cluster V15 is analyzed with the emphasis on the origin of the mixing of different spin levels in the resonance fields that is generally important for the problem of single molecular magnets. The zero-field splitting in the ground quadruplet (two Formula Not Shown levels) is shown to depend mainly on the normal component of AS exchange meanwhile the zero-field splitting in the excited Formula Not Shown multiplet is a second order effect with respect to in-plane components of AS exchange. The normal component of the AS exchange is shown to lead to the exact crossing of the magnetic sublevels at the arbitrary direction of the field. The positions of two crossing/anticrossing points in the ground manifold depend mainly on the iso...
Application of the Geographic Information System (GIS) with a statistical model to evaluate the magnetic field exposure of a population from high-voltage transmission lines near residential areas is discussed, focusing on the interaction of the GIS with the statistical model. In an effort to validate the model measurements of the magnetic field, profiles were taken at two sites and these profiles have been compared with calculated values. Two conclusions have been drawn from the results: (1) the statistical model linked with the GIS is a very powerful tool for the evaluation of exposure of a population to magnetic fields, and (2) success depends on the presence of other sources of magnetic fields and on the exactness of the data used in the model. 4 refs., 5 figs.
Magnetic properties of layer ferromagnets against the thickness are investigated. Two new compounds served for studies: Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1. The Moessbauer effect and the magnetic susceptibility measurements were applied in the experiment. The Faraday method was used in magnetic measurements in fields from 1 to 9,5 kOe. The results of Moessbauer measurements show that temperature dependence of the spectra is typical for compounds with superparamagnetic properties. The magnetic fields Hsub(n) on Fe"5"7 nuclei in Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1 are similar and equal to 520+-10 kOe. Therefore it may be concluded that relaxation times of nuclear spins in these compounds are equal or close to each other. The lines of quadrupole splitting appear in spectra together at 20 K. The results of magnetic ...
We have performed X-ray magnetic diffraction (XMD) experiment of ferromagnets at the Photon Factory (PF) of the High Energy Accelerator Research Organization (KEK) in Tsukuba. In this study, we have upgraded the XMD experimental system in order to apply this method to as many samples as possible. Upgrade was made for (1) the X-ray counting system and related measurement program, (2) the electromagnet, and (3) the refrigerator. The performance of the system was enhanced so that (1) the counting rate capability was improved from 104cps to 105cps, (2) the maximum magnetic field was increased from 0.85T to 2.15T, and (3) the lowest sample temperature was reduced from 15K to 5K. The new system was applied to an orbital ordering compound of YTiO3, and we obtained spin magnetic form factor for the reflection plane (010) perpendicular to the b axis. The magnetic field of 2T was needed to saturate the ...
One of the major achievements of the magnet R&D program for the Superconducting Super Collider (SSC) is the fabrication and test of a series of 20 5-cm aperture, 15-m long dipole magnet prototypes. The ramp rate sensitivity of these magnets appears to fall in at least two categories that can be correlated to the manufacturer and production batch of the strands used for the inner-coil cables. The first category, referred to as type-A, is characterized by a strong quench current degradation at high ramp rates, usually accompanied by large distortions of the multipole fields and large energy losses. The second category, referred to as type-B, is characterized by a sudden drop of quench current at low ramp rates, followed by a much milder degradation at larger rates. The multipole fields of the type-B magnets show little ramp-rate sensitivity, and the energy losses are smaller than for the type-A ...
The results of x-ray diffraction, dc magnetization, and 61Ni Moessbauer spectroscopy studies of the ternary arsenide CrNiAs are reported. This compound crystallizes in the orthorhombic Fe2P-type structure (space group P6-bar2m) with the lattice parameters a 6.1128(2) A and c = 3.6585(1) A. CrNiAs is a mean-field ferromagnet with Curie temperature TC = 171.9(1) K and the critical exponents ? 0.514(18), ? = 1.010(16), and ? = 2.922(10). The temperature dependence of the magnetic susceptibility above TC follows the modified Curie-Weiss law with a paramagnetic Curie temperature of 176.0(3) K and effective magnetic moment per transition metal atom of 2.42(1) ?B. The magnetic moment per formula unit at 4.2 K is found to be 1.114(33) ?B. The hyperfine magnetic field at 61Ni nuclei at 4.2 K of 41.5(1.0) kOe implies that the Ni atoms carry a magnetic moment of 0.15(3) ...
Heusler alloys are considered as interesting ferromagnetic electrode materials for magnetic tunnel junctions, because of their high spin polarization. We, therefore, investigated the micromagnetic properties in a prototypical thin film system comprising two different Heusler phases Co{sub 2}MnSi (CMS) and Co{sub 2}FeSi (CFS) separated by a MgO barrier. The magnetic microstructure was investigated by X-ray photoemission electron microscopy (XPEEM). We find a strong influence of the Heusler phase formation process on the magnetic domain patterns. SiO{sub 2}/V/CMS/MgO/CFS and SiO{sub 2}/V/CFS/MgO/CMS trilayer structures exhibit a strikingly different magnetic behavior, which is due to pinhole coupling through the MgO barrier and a strong thickness dependence of the magnetic ordering in Co{sub 2}MnSi.
The three-dimensional magnetic structure and reversal mechanism of patterned Co/Pt multilayers, were imaged using complementary Lorentz transmission electron microscopy (LTEM) (in-plane component) and magnetic transmission x-ray microscopy (M-TXM) (perpendicular magnetization). The Co/Pt films with perpendicular anisotropy were patterned by ion irradiation through a stencil mask to produce in-plane magnetization in the irradiated regions. The boundaries of the patterns, defined by the transition from out-of-plane to in-plane magnetization, were found to be determined by the stencil mask, whilst the scale of the magnetic reversal by the physical microstructure. The nucleation fields were substantially reduced to 50 Oe for the in-plane regions and 1 kOe for the perpendicular regions, comparing to 4.5 kOe for the as-grown film. The perpendicular reversals were ...
DC resistivity, dc magnetization, and specific heat of eight Sc{sub 5}Co{sub 4}Ge{sub 10}-type crystal-structure compounds R{sub 5}T{sub 4}Ge{sub 10} for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single-crystal magnetization, and specific-heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like {theta} reflects the strength of the crystal-field torque on the ...
DC resistivity, dc magnetization, and specific heat of eight Sc/sub 5/Co/sub 4/Ge/sub 10/-type crystal structure compounds R/sub 5/T/sub 4/Ge/sub 10/ for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single crystal magnetization, and specific heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients ..cap alpha../sub j/, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like theta reflects the strength of the crystal field torque ...
In this review, we show how advances in the theory of magnetic pseudodifferential operators (magnetic $\\Psi$DO) can be put to good use in space-adiabatic perturbation theory (SAPT). As a particular example, we extend results of [PST03] to a more general class of magnetic fields: we consider a single particle moving in a periodic potential which is subjectd to a weak and slowly-varying electromagnetic field. In addition to the semiclassical parameter $\\eps \\ll 1$ which quantifies the separation of spatial scales, we explore the influence of additional parameters that allow us to selectively switch off the magnetic field. We find that even in the case of magnetic fields with components in $C_b^{\\infty}(\\R^d)$, e. g. for constant magnetic fields, the results of Panati, Spohn and Teufel hold, i.e. to each isolated family of Bloch bands, there exists an ...
Using the full potential linearized augmented plane wave (FLAPW) method, the magnetic properties of two-dimensional Ru and Rh monolayers (MLs) on a NiAl(001) surface have been investigated. It has been found that free standing one monolayer Ru and Rh films have ferromagnetic ground state with magnetic moments of 2.21 and 1.48 #mu#_B, respectively. The ferromagnetism is still observed even on a Ni terminated NiAl(001) surface, while no magnetic state is found on an Al terminated surface. The calculated magnetic moments of Ru and Rh atoms are 1.56 and 0.88 #mu#_B, respectively. In addition, an induced magnetic moment in surface Ni is observed. It has been found that the free standing Ru film has perpendicular magnetization to the film surface with a magnetocrystalline anisotropy (MCA) energy of 0.66 meV/atom, while an in-plane MCA energy of 0.37 meV/atom is ...
This report summarizes the results and activities funded by this three-year award. The principal goal of this project was to determine the thermal conductivity in clusters of galaxies. Intracluster plasmas possess chaotic magnetic fields. Since charged particles are constrained to move primarily along magnetic field lines, the topology of intracluster magnetic fields slows particle diffusion relative to the non-magnetized case, thereby reducing the thermal conductivity. Our first approach to this problem was to employ the static-magnetic-field approximation. In reality, intracluster magnetic field lines are constantly moving, since they are advected by turbulent intracluster motions. The turbulent velocities, however, are much smaller than the rapid speeds of thermal electrons, which make the dominant contribution to the thermal conductivity. In the static-field ...
Experimental investigations are presented which demonstrate that the weak ferromagnets are special materials of a larger group of magnets which exhibit two magnetic ordering structures. In weak ferromagnets the main order is antiferromagnetic with a small ferromagnetic component existing in addition. On the other hand, materials in which other combinations of the two basic ordering structures coexist are also known. Common to all these non-collinear spin structures is that the moment components of the two magnetic structures are orthogonal. In the weak ferromagnets this orthogonality manifests already in the paramagnetic phase as a crossover from an isotropic to an anisotropic susceptibility with respect to the applied magnetic field: at high temperatures the antiferromagnetic Curie-Weiss law of the total moment is observed while for T->Tc crossover to a second Curie-Weiss law due to the weak ...
Over the last year-and-a-half, several 4-cm-aperture, 17-m-long dipole magnet prototypes were built by Brookhaven National Laboratory (BNL) under contract with the Superconducting Super Collider (SSC) Laboratory. These prototypes are the last phase of a half-decade-long R D program, carried out in collaboration with Fermi National Accelerator Laboratory and Lawrence Berkeley Laboratory, and aimed at demonstrating the feasibility of the SSC main ring dipole magnets. They also prepare the way of the 5-cm-aperture dipole magnet program to be started soon. In this paper, we analyze the mechanical behavior of the BNL prototypes during cool-down and excitation, and we attempt to relate this behavior to the magnet features. The data reveal that the mechanical behavior is sensitive to the vertical collar-yoke interference, and that the magnets exhibited somewhat erratic changes in coil ...
In vacuum arcs of interest for ion deposition, in which a magnetic filter is used, significant plasma rotation about the filter axis can develop. In the present work we present experimental evidence and simplified models to interpret relatively fast rotation of plasma generated in a pulsed vacuum arc with a straight magnetic filter and with a magnetic field strength in the range 52-430 G. The plasma rotation is produced in the first part of the filter (the driving region) where either the expanding or the contracting plasma encounters a mainly axial magnetic field. In the next part of the filter (the rotation region) a quasi-equilibrium is achieved and the plasma does not evolve further significantly. A rigid-rotor type of equilibrium is considered to model the rotation region, with experimentally obtained parameters, and a simple model is employed in the driving region to quantify the magnitude of the ...
The term ``dynamo'' means different things to the laboratory fusion plasma and astrophysical plasma communities. To alleviate the resulting confusion and to facilitate interdisciplinary progress, we pinpoint conceptual differences and similarities between laboratory plasma dynamos and astrophysical dynamos. We can divide dynamos into three types: 1. magnetically dominated helical dynamos which sustain a large scale magnetic field against resistive decay and drive the magnetic geometry toward the lowest energy state, 2. flow-driven helical dynamos which amplify or sustain large scale magnetic fields in an otherwise turbulent flow, and 3. flow-driven nonhelical dynamos which amplify fields on scales at or below the driving turbulence. We discuss how all three types occur in astrophysics whereas plasma confinement device dynamos are of the first type. Type 3 dynamos requires no ...
The LHC magnet tests operation team developed various innovative techniques, particularly since early 2004, to complete the superconductor magnet tests by Feb. 2007. Overall and cryogenic priority handling, rapid on-bench thermal cycling, rule-based goodness evaluation on round-the-clock basis, multiple, mashed web systems are some of these techniques applied with rigour for successful tests completion in time. This paper highlights these operation empowerment tools which had a pivotal role for success. A priority handling method was put in place to enable maximum throughput from twelve test benches, having many different constraints. For the cryogenics infrastructure, it implied judicious allocation of limited resources to the benches. Rapid On-Bench Thermal Cycle was a key strategy to accelerate magnets tests throughput, saving time and simplifying logistics. First level magnet appraisal was developed ...
Magnetic imaging in the transmission electron microscope (TEM) has been used to examine submicron elements with the aim of discovering down to what element size complex domain patterns can form. The elements were squares, circles, triangles, and pentagons in the size range 100{endash}500 nm and were made from 36 nm Co films or 8 nm Ni{sub 80}Fe{sub 20} (NiFe) with in-plane magnetization. The magnetic domain structures in these elements were imaged at high resolution using the differential phase contrast imaging mode in a TEM. Nonuniform magnetization structures were seen in the images. Vortices were present at remanence in all shapes of 36-nm-thick Co elements down to 100 nm size and in circular NiFe elements down to 116 nm diameter. Triangular NiFe elements did not have a vortex state at remanence, instead the magnetization curved round within the element but did not achieve ...
Ho{sub 2}CuTiO{sub 6} double pervoskite is synthesized by solid state reaction method and the phase formation was confirmed by X-ray diffraction. Ho{sub 2}CuTiO{sub 6} crystallizes in space group P63 cm and are isostructural in AMnO{sub 3} structure. We have investigated the effect of the presence of a magnetic ion (Ho{sup 3+}{approx}10.4{mu}{sub B}) in Ho{sub 2}CuTiO{sub 6}, on the magnetic properties, compared to that of an isostructural double perovskite containing Y-ion (non-magnetic), i.e., Y{sub 2}CuTiO{sub 6}. Magnetization measurements on Ho{sub 2}CuTiO{sub 6} showed paramagnetic moment of 0.026{mu}{sub B}/Ho at room temperature in an applied field of 7 T although no saturation is observed at room temperature, whereas, at 5 K, the paramagnetic moment was 0.3{mu}{sub B}/Ho in the same field. Since this compound is non-centrosymmetric, it is of interest to look into the possibility of realizing ...
We present an x-ray magnetic circular dichroism (XMCD) study performed on both Ho{sub 6}Fe{sub 23} and Y{sub 6}Fe{sub 23} compounds as a function of the temperature. The combined analysis of both Fe K-edge and Ho L{sub 2,3}-edge XMCD spectra recorded through the magnetic compensation transition allows us to disentangle the thermal dependence of both Fe and Ho magnetic moments in Ho{sub 6}Fe{sub 23}. In addition, contributions from Ho ions to the Fe K-edge XMCD signals and, conversely, from Fe ions to the Ho L{sub 2,3}-edge XMCD spectra have been clearly identified. These extra contributions, arising from the strong Fe(3d)-Ho(5d) hybridization, have been isolated from the spectra and correlated with the magnetic state of both Ho and Fe ions surrounding the absorbing site. The influence of these contributions to the values of the orbital and spin moments derived by using sum rule analysis is also shown.
Holmium doped barium based hexaferrites BaFe12-2xHo2xO19 with (x=0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho^3^+ acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (Ms), remanent magnetization (Mr) and coercivity (Hc) were observed by changing Ho^3^+ content in BaFe12-2xH...
Holmium doped barium based hexaferrites BaFe_1_2_-_2_xHo_2_xO_1_9 with (x = 0.0-1.0) were synthesized by solid state reaction method. Structural and magnetic characterization of these ferrites provide significant information about their reactive physical properties. X-ray analysis reveals that in all samples M-type structure exist with few secondary phases. Scanning electron microscope revealed the grain size of the specimen. The results show that grain size decreases with the substitution degree of Holmium. Thus rare earth element Holmium Ho"3"+ acts as a grain growth inhibitor. The magnetic hysteresis loops show the variation in the values of magnetic parameters like saturation magnetization (M_s), remanent magnetization (M_r) and coercivity (H_c) were observed by changing Ho"3"+ content in BaFe_1_2_-_2_xHo_2_xO_1_9 ferrites. Coercivity showed a maximum value of 2230 Oe for (x = ...
The X-ray spectra of some magnetized isolated neutron stars (NSs) show absorption features with equivalent widths (EWs) of 50 - 200 eV, whose nature is not yet well known. To explain the prominent absorption features in the soft X-ray spectra of the highly magnetized (B ~ 10^{14} G) X-ray dim isolated NSs (XDINSs), we theoretically investigate different NS local surface models, including naked condensed iron surfaces and partially ionized hydrogen model atmospheres, with semi-infinite and thin atmospheres above the condensed surface. We also developed a code for computing light curves and integral emergent spectra of magnetized neutron stars with various temperature and magnetic field distributions over the NS surface. We compare the general properties of the computed and observed light curves and integral spectra for XDINS RBS\\,1223 and conclude that the observations can be explained by a thin ...
The magnetically fluidized bed (MFB) was used as the reactor in a novel semidry flue gas desulfurization (FGD) process to achieve high desulfurization efficiency. Experiments in a laboratory-scale apparatus were conducted to reveal the effects of approach to adiabatic saturation temperature, Ca/S molar ratio and applied magnetic field intensity on SO(2) removal. Results showed that SO(2) removal efficiency can be obviously enhanced by decreasing approach to adiabatic saturation temperature, increasing Ca/S molar ratio, or increasing applied magnetic field intensity. At a magnetic field intensity of 300Oe and a Ca/S molar ratio of 1.0, the desulfurization efficiency (excluding desulfurization efficiency in the fabric filter) was over 80%, while spent sorbent appeared in the form of dry powder. With the SEM, XRD and EDX research, it can be found that the increase of DC magnetic field ...
Gantries in the proton/carbon cancer therapy machines represent the major cost and are of the largest size. This report explains a new way to the gantry design. The size and cost of the gantries are reduced and their use is simplified by using the fixed magnetic field. The ''new'' gantry is made of a very large momentum acceptance non-scaling Fixed Field Alternating Gradient (FFAG) quarter and half arc beam lines. The gantry is made of combined function magnets with a very strong focusing and small dispersion function. Additional magnets with a fast response are required to allow adjustments of the beam position for different energies at the beginning of the gantry. Additional strong focusing magnets following the gantry have also to be adjustable to provide required spot size and radial scanning above the patients. The fixed field combined function ...
The sharp, temperature induced, continuous valence transition in EuPd/sub 2/Si/sub 2/ is drastically changed by doping with Sn at the Si site up to 5 at.%. Only a first order valence transition occurs for a 3% Sn doped sample and the 2/sup +/ component which survives the valence transition orders magnetically at 4.2 K. No valence transition at all occurs for a 5% Sn doped sample right up to 1.9 K and magnetic ordering sets in around 30 K.
Full text: Magnetic multilayer materials are becoming technologically important as they provide a more efficient means of magnetic reading and storage through utilisation of their giant magnetoresistance and oscillatory magnetic coupling. This study presents preliminary tight-binding calculations with a view of developing a consistent tight-binding model of `spin valve` Fe-Cu-Fe tri-layer materials. Further work involves using a self-consistent tight-binding approach to obtain a more accurate picture of this system and a better understanding of surface effects at the Fe-Cu interface 1 fig., 4 refs.
A total of 50 000 tonnes of low-carbon steel sheet has been ordered for the LHC main magnets. After three years of production, about 10 000 tonnes of steel sheet have been produced by Cockerill-Sambre Groupe Usinor. This paper gives a summary of the manufacturing process and improvements implemented as well as an overview of the difficulties encountered during this production. Preliminary statistics obtained for the mechanical and magnetic steel properties are presented. (6 refs).
Superconducting magnetic and inertial energy pulsed power systems are being developed for future theta-pinch, Tokamak, and laser fusion applications. The short term requirements for these applications are discussed along with present day accomplishments. Areas requiring a research and development effort are examined in detail. Subjects discussed include stresses, energy loss factors, conductor metallurgy, cryogenic requirements, and electrical limitations of superconducting magnetic storage systems; costs, applications, and present technology of homopolar systems; and switching problems associated with both systems.
A calculation is presented of spontaneous radiation emitted by an electron beam passing through a continuously rotating quadrupole magnetic undulator. It is shown that radiation spectrum emitted in forward direction of beam propagation has four peaks, corresponding to four betatron frequencies. Utilizing the Madey theorem, a stimulated emission is calculated and presented as gain versus frequency curves, for different values of the quadrupole magnetic field. A free-electron laser operating at two or three radiation frequencies with a quadrupole magnetic wiggler is suggested.
CERN has encouraged the US-LARP collaboration to participate in Phase I of the LHC luminosity upgrade by analyzing the benefits gained by using Nb3Sn technology to replace the functionality of select NbTi magnets that CERN is committed to construct. Early studies have shown that the much higher gradients (shorter magnetic lengths) and temperature margins (quench stability) of Nb3Sn magnets compared to their NbTi counterparts is favorable--allowing the insertion of additional absorbers between Q1 and Q2, for example. This paper discusses the relative merits of the NbTi and Nb3Sn options.
We present the synthesis, magnetic and UV spectrometry of NiZn-ferrite nanofiber. The single phase of spinel ferrite was obtained at 600 {sup o}C. The NiZn-ferrite fibers fabricated by an electrospinning process were formed as a polygonal grain growth with firing temperature in fiber matrix. It appeared that the saturation magnetization (M{sub S}) of NiZn-ferrite nanofiber was dependent on Ni/Zn molar ratio which is similar to that of the inverse spinel ferrites. The NiZn-ferrite fibers showed good DNA adsorption efficiency that can be modified and utilized for DNA separation with magnetic nanofiber as a novel material in clinical applications.
The present paper investigates the peristaltic transport of a couple stress fluid in an asymmetric channel with the effect of the induced magnetic field. The exact solutions of momentum and the magnetic field equations have been calculated under the assumptions of long wave length and low but finite Reynolds number. The expression for pressure rise has been computed numerically using mathematics software Mathematica. The graphical results have been presented to discuss the physical behavior of various physical parameters of interest. Finally, the trapping phenomena have been discussed for various physical parameters. (orig.)
The present paper investigates the peristaltic transport of a couple stress fluid in an asymmetric channel with the effect of the induced magnetic field. The exact solutions of momentum and the magnetic field equations have been calculated under the assumptions of long wave length and low but finite Reynolds number. The expression for pressure rise has been computed numerically using mathematics software Mathematica. The graphical results have been presented to discuss the physical behavior of various physical parameters of interest. Finally, the trapping phenomena have been discussed for various physical parameters.
The DC magnetic susceptibility of the REBa_2F_7 compounds was measured by a SQUID magnetometer in the temperature range 5-300 K. Except for Eu, the other compounds show either Curie law or Curie-Weiss law with relatively small values of paramagnetic Curie temperature, #theta#_p, with effective magnetic moments in the range expected of electronic ground state of the trivalent rare earth ion with appropriate J value. The behaviour of Eu is complex. (orig.).
The magnetic field strengths of most millisecond pulsars(MSP) are about $10^{8-9}$ Gauss. The accretion induced magnetic field evolution scenario here concludes that the field decay is invesely related to the accreted mass and the minimum field or bottom field stops at about $10^{8}$ Gauss if accreted with the Eddington accretion rate, which is proportionally related with the accretion rate as $\\dot{M}^{1/2}$. The possibility of the low field $\\sim 10^{7}$ Gauss MSPs has been proposed for the future radio observation.
The problem of thermal instability of compressible, electrically conducting couple-stress fluids in the presence of a uniform magnetic field is considered. Following the linearized stability theory and normal mode analysis, the dispersion relation is obtained. For stationary convection, the compressibility, couple-stress, and magnetic field postpone the onset of convection. Graphs have been plotted by giving numerical values of the parameters to depict the stability characteristics. The principle of exchange of stabilities is found to be satisfied. The magnetic field introduces oscillatory modes in the system that were non-existent in its absence. The case of overstability is also studied wherein a sufficient condition for the non-existence of overstability is obtained. (orig.)
Magnetic behavior in three compounds RTa{sub 3}O{sub 9} (R = Nd, Eu and Ho) with defect-perovskite structures has been investigated by DC magnetic susceptibility. The susceptibility of NdTa{sub 3}O{sub 9} shows strong influence of crystal field. For EuTa{sub 3}O{sub 9} a typical Van Vleck paramagnetism has been observed. HoTa{sub 3}O{sub 9} obeys a Curie-Weiss law above 20 K. (orig.) 8 refs.
The results obtained from the magnetization, specific heat and electrical resistivity measurements on a polycrystalline sample of Pr_2Pd_3Si_5 are reported. The temperature dependence of magnetic susceptibility at low field (0.01 T) exhibits pronounced anomaly below 7 K due to antiferromagnetic ordering. The electrical resistivity and specific heat data also exhibit sharp transition at 6.6 K evidencing the onset of antiferromagnetic order. A fit to the electrical resistivity data below 6 K suggests the presence of an energy gap in magnon spectrum in the ordered state. (author)
Self-magnetically insulated, high-voltage transmission lines are used in inertial confinement fusion particle accelerators in order to transmit power from the vacuum insulator to the diode. This paper describes a time-dependent 2-D code (MITL) for calculating (for planar or triplate geometries) the motion of test electrons through the tapered input or output convolutes of such lines. MITL results show that the electron canonical momentum in the direction of the flow changes as the electron passes through the convoluted geometry; it is suggested that these electrons lead to losses observed in long self-magnetically insulated lines.
The orbit response matrix (ORM) method [1] is applied to model the Fermilab Booster with parameters such as the BPM gains and rolls, and parameters in the lattice model, including the gradient errors and magnets rolls. We found that the gradients and rolls of the adjacent combined-function magnets were deeply correlated, preventing full determination of the model parameters. Suitable constraints of the parameters were introduced to guarantee an unique, equivalent solution. Simulations show that such solution preserves proper combinations of the adjacent parameters. The result shows that the gradient errors of combined-function magnets are within design limits.
The Compact Muon Solenoid (CMS) is one of the experiments which are being designed in the framework of the Large Hadron Collider (LHC) project at CERN. The design field of the CMS magnet is 4 T, the magnetic length is 12.38 m and the aperture is 6.36 m. This is achieved with a 4 layer-5 module superconducting Al-stabilized coil energised at a nominal current of 20 kA. The finite element analysis (FEA) carried out is axisymmetric elasto-plastic. FEA has also been carried out on the suspension system and on the conductor. (8 refs).
Electron paramagnetic resonance was used to investigate surface-coated magnetite-based magnetic fluids doped with TEMPOL. Two magnetic fluid samples, having magnetite nanoparticles with average diameter of 94 A and coated with different coating layers (lauric acid plus ethoxylated polyalcohol in one case and oleoylsarcosine in the other case), were doped with TEMPOL (6 mM and pH 7.4) and investigated as a function of the nanoparticle concentration. The resonance field and the resonance linewidth both scale linearly with the nanoparticle concentration.
Two new identical insertion devices have been designed for the Daresbury SRS. They are 2T permanent-magnet multipole wigglers that will provide high flux in the X-ray region. This paper describes the magnetic and mechanical design of the arrays of steel pole pieces and permanent-magnet blocks. Also given is the engineering design of the support structure that will cope with the very large forces present while maintaining high levels of precision in gap setting and parallelism. The engineering design has been fully assessed using finite-element techniques to predict the deflections of critical parts of the structure. These two devices are due to be installed into the SRS by the end of 1998.
The ZnO nanorods were used as a template to fabricate nickel nanoclusters by electrodeposition. The ZnO nanorod arrays act as a nano-semiconductor electrode for depositing metallic and magnetic nickel nanoclusters. The growth sites of Ni nanoclusters could be controlled by adjusting the applied potential. Under -1.15 V the Ni nanoclusters could be grown on the tips of ZnO nanorods. On increasing the potential to be more negative the ZnO nanorods were covered by Ni nanoclusters. The magnetic properties of the electrodeposited Ni nanoclusters also evolved with the applied potentials.
Differentiating characteristics of magnetic confinement systems having externally generated magnetic fields that are open'' are listed and discussed in the light of their several potential advantages for fusion power systems. It is pointed out that at this stage of fusion research high-Q'' (as deduced from long energy confinement times) is not necessarily the most relevant criterion by which to judge the potential of alternate fusion approaches for the economic generation of fusion power. An example is given of a hypothetical open-geometry fusion power system where low-Q operation is essential to meeting one of its main objectives (low neutron power flux).
This paper is devoted to investigate the influences of thermal dispersion and magnetic field on a hot semi-infinite vertical porous plate embedded in a saturated Darcy-Forchheimer-Brinkman porous medium. The coefficient of thermal diffusivity has been assumed to be the sum of the molecular diffusivity and the dynamic diffusivity due to mechanical dispersion. The effects of transverse magnetic field parameter (Hartmann number Ha), Reynolds number Re (different velocities), Prandtl number Pr (different types of fluids) and dispersion parameter on the wall shear stress and the heat transfer rate are discussed.
Borrelia burgdorferi sensu lato genospecies were differentiated by PCR-based sequencing of the borrelial flagellin gene. To evaluate the usefulness of KingFisher"T"M magnetic particle processor in PCR product purification, borrelia PCR products were purified with KingFisher"T"M magnetic particle processor prior to cycle sequencing and the quality of the sequence data received was analyzed. KingFisher was found to offer a rapid and reliable alternative for borrelial PCR product purification.
The baseline design for the SSC High Energy Booster (HEB) has dipole bending magnets with a 50 mm aperture. An analysis of the cryogenic heat load due to A.C. losses generated in the HEB ramp cycle are reported for this magnet. Included in this analysis are losses from superconductor hysteresis, yoke hysteresis, strand eddy currents, and cable eddy currents. The A.C. loss impact of 2.5 {mu}m vs. 6 {mu}m filament conductor is presented. A 60 mm aperture design is also investigated. 8 refs., 3 tabs.
The future use of single-molecule magnets in applications will require the ability to control and manipulate the spin state and magnetization of the magnets by external means. There are different approaches to this control, one being the modification of the magnets by adsorption of small ligand molecules. In this paper we use iron phthalocyanine supported by an Au(111) surface as a model compound and demonstrate, using x-ray photoelectron spectroscopy and density functional theory, that the spin state of the molecule can be tuned to different values (S #approx# 0, 1/2, 1) by adsorption of ammonia, pyridine, carbon monoxide or nitric oxide on the iron ion. The interaction also leads to electronic decoupling of the iron phthalocyanine from the Au(111) support. (fast track communication)
Polymer insulating materials used in radioactive environments are subjected to a risk of surface degradation caused by tracking. The tracking behavior becomes more complex with the presence of magnetic field. This paper presents investigation of tracking failure of gamma-ray irradiated polybutylene naphthalate (PBN) and polybutylene terephthalate (PBT) under magnetic field. The samples were irradiated in air up to 100 kGy and then up to 1000 kGy with dose rate of 10 kGy/h by using a 60Co gamma-source. Magnetic field Formula Not Shown with flux density of 250 mT was assembled perpendicularly to electric field Formula Not Shown , which gave rise to relative angle between Formula Not Shown and surface normal vector Formula Not Shown of 0degree, 90degree and 180degree, respectively. The experi...
... charge carriers in strained p-Ge in crossed electric and magnetic fields was studied by means of measurements of spontaneous radiation intensity. ...
The measurements performed at CERN on prototypes and first pre-series main dipole magnets confirm the need of an active control of the Large Hadron Collider to compensate the dynamic field changes during the proton beam injection and acceleration. This control requires in turn an accurate forecast of the magnetic field in the accelerator. We plan to predict the field on the basis of two elements: theoretical field models tailored through the accumulated knowledge of the main magnets during series tests, and an on-line measurement system running on few reference magnets tracking the LHC current cycle. Data coming from this "Multipoles Factory" will result from the fusion of the two sources. Based on this system we foresee to deliver calibration information for pre-defined accelerator cycles as well as real time information for the active control. In this paper we report the conceptual design of the ...
We present results on searches for exotic particles (relativistic magnetic monopoles and WIMPs) and for UHE neutrinos, obtained with the Baikal neutrino telescope NT200.
Background/Objective:Tarlov cysts or spinal perineurial cysts are uncommon lesions. These are mostly incidental findings on magnetic resonance imaging or myelograms. The...Full Text Available
The magnetic ordering temperature of some rare-earth-based heavy-fermion compounds is strongly pressure dependent and can be completely suppressed at a critical pressure, p{sub c}, making way for novel correlated electron states close to this quantum critical point. We have studied the clean heavy-fermion antiferromagnets CePd{sub 2}Si{sub 2} and CeIn{sub 3} in a series of resistivity measurements at high pressures up to 3.2 GPa and down to temperatures in the mK region. In both materials, superconductivity appears in a small window of a few tenths of a GPa on either side of p{sub c}. We present detailed measurements of the superconducting and magnetic temperature-pressure phase diagram, which indicate that superconductivity in these materials is enhanced, rather than suppressed, by the closeness to magnetic order. (author)
The magnetic ordering temperature of some rare-earth-based heavy-fermion compounds is strongly pressure dependent and can be completely suppressed at a critical pressure, p_c, making way for novel correlated electron states close to this quantum critical point. We have studied the clean heavy-fermion antiferromagnets CePd_2Si_2 and CeIn_3 in a series of resistivity measurements at high pressures up to 3.2 GPa and down to temperatures in the mK region. In both materials, superconductivity appears in a small window of a few tenths of a GPa on either side of p_c. We present detailed measurements of the superconducting and magnetic temperature-pressure phase diagram, which indicate that superconductivity in these materials is enhanced, rather than suppressed, by the closeness to magnetic order. (author)
Spin-polarized angle-resolved sulfur L_2_,_3VV Auger-electron spectra have been recorded for the c(2x2)S/Fe(001) system. The data show the modulation of the sulfur Auger spin polarization as a function of emission angle, which represents an observation of spin-polarized Auger-electron diffraction (SPAED), a potentially powerful tool for the study of local magnetic structure at surfaces, interfaces, and thin films. Theoretical modeling of the SPAED data indicates a large decrease in the magnetization of the top iron layer, suggesting a magnetic poisoning induced by the sulfur overlayer. These findings are independently supported by the observation of a large decrease of secondary electron spin polarization upon sulfur adsorption.
... explosive (shotgun shells, etc.) method of forming is being replaced--for the most part--by the electri- cal discharge and magnetic forming methods. ...
A shipbuilder is using an electro-magnetic forming system (on loan from NASA) in a development program. " A modification in the design of a metal bending ...
The existence of multipole components in the dipole and quadrupole magnets is one of the factors limiting the beam stability in the RHIC operations. So, a realistic non-linear model is crucial for understanding the beam behavior and to achieve the ultimate performance in RHIC. A procedure is developed to build a non-linear model using the available multipole component data obtained from measurements of RHIC magnets. We first discuss the measurements performed at different stages of manufacturing of the magnets in relation to their current state in RHIC. We then describe the procedure to implement these measurement data into tracking models, including the implementation of the multipole feed down effect due to the beam orbit offset from the magnet center. Finally, the field quality analysis in the RHIC interaction regions (IR) is presented.
Purpose - The purpose of this paper is to investigate the accuracy of different force calculation methods and their impact on mechanical deformations. For this purpose, a micrometer scaled actuator is considered, which consists of a micro-coil and of a permanent magnet (PM) embedded in a deformable elastomeric layer. Design/methodology/approach - For the magnetic field evaluation a hybrid numerical approach (finite element method/boundary element method (FEM/BEM) coupling and a FEM/BEM/Biot-Savart approach) is used, whereas FEM is implemented for the mechanical deformation analysis. Furthermore, for the magneto-mechanical coupling several force calculation methods, namely the Maxwell stress tensor, the virtual work approach and the equivalent magnetic sources methods, are considered and co...
Noncollinear (NC) magnetism is common in nature, especially when there exist geometrical frustration and chemical imparity in the system. In this work we studied the NC magnetism and the response to external magnetic fields in surfaces and interfaces of transition metals by using an semi-empirical tight-binding (TB) method that parameterized to the ab initio TB-LMTO calculations. We implemented this method to study two systems. The first one is the system of 6 Mn monolayers on Fe(001) substrate. Due to the complex structure and magnetic properties of Mn, we found 23 collinear magnetic configurations but only one NC configuration. The collinear ground state has a layered antiferromagnetic (AFM) coupling which agrees with previous experiments and calculations. In the NC configuration the local AFM coupling in the Mn layers is preserved, but the surface is 90 degree coupled to the ...
In this article a production method of a magnetorheological suspension composed with silicon steel particles of size 0.1-0.15 mm and 4% silicon content is described. Steel particles were dispersed in a conducting carrier of a by mixture of graphite particles with size 2-5 {mu}m and cedar wood oil. The filling factor of the suspension with the silicon steel particles and with graphite particles amounted to 0.25-0.40. Samples of this suspension were placed in a rectangular vessel with electrodes and used for the investigation of the Hall effect in magnetic field with induction 0-8 T, generated by Bitter-type magnet. A non-linear dependence of Hall voltage on the induction of the applied magnetic field and a hysteresis loop of this voltage in the shape of inclined digit eight were found. The causes of the observed effects is the ordering of silicon steel particles and graphite particles along the side of ...
The temperature dependence of the average magnetization direction in an Fe_8_0B_2_0 glassy alloy (METGLAS 2605) is investigated by Moessbauer spectroscopy. Moessbauer spectra were recorded between 77 K and 363 K using a conventional constant-acceleration Moessbauer spectrometer with 10 mCi "5"7Co in Pd source. The direction of the easy magnetization is found to be strongly terperature dependent and the out-of-plane component turned to be unusually large. Comparing the magnetic moments some similarities between the electronic structure of the glassy alloy and the Fe_2B and FeB intermetallic compounds are established and discussed. (Sz.N.Z.).
Neutron diffraction and magnetometric measurements on polycrystalline samples of DyPd_2Si_2 and ErPd_2Si_2 were carried out in the temperature range from 2 to 293 K. Both compounds show tetragonal ThCr_2Si_2 type crystal structure and order at 12 K in a sine modulated magnetic structure with propagation vectors k=[0.609,0,0.155] and [0.575, 0, 0.083] respectively. The oscillatory character of magnetic order found in RPd_2Si_2 (R=Tb-Er) compounds suggests exchange interaction described by the RKKY model to be dominant, but the non-monotonic dependence of respective Neel temperatures on the number of f-electrons indicates the influence of a crystalline electric field (CEF) on the magnetic behaviour in this series. (orig.).
Samples of Fe78B13Si9 (Metglas 2605 TCA) and Fe77Cr2B16Si5 (Metglas 2605 S3A) were exposed to pulsed excimer laser irradiation at repetition rates of 15, 25 and 50Hz. The occurrence of out-of-plane magnetic anisotropy, changes in the average hyperfine magnetic field and width of the hyperfine field distribution were evidenced by transmission Mossbauer spectroscopy. The variation of the recoilless fraction with laser processing parameters was derived from the simultaneous recording of Mossbauer spectra using a stainless steel etalon as a dual absorber. Conclusions on the onset of long-range magnetic order were formulated.
A theoretical analysis of formation and symmetry transformations is presented for Wigner molecules with N = 2,..., 20 electrons confined in quantum dots at high magnetic fields. Using the unrestricted Hartree-Fock method with the multicentre Gaussian basis, we have found that Wigner molecules with N {>=} 6 abruptly change their shape and symmetry with an associated jump in the first derivative of the ground-state energy, i.e. they undergo phase transitions. In particular, the phases of the Wigner molecules obtained just after emerging from the maximum-density droplet (MDD) phase possess a different symmetry from that formed at a high magnetic field. We show that the properties of the electron-electron interaction energy demonstrate very well both the breakdown of the MDD and the quasi-classical character of the Wigner molecule in the high magnetic field. Possible mechanisms of the MDD decay are discussed.
The MRI's of 16 patients with either primary or secondary lymphatic disorders are evluated and the findings are compared to those from lymphangioscintigraphy or surgery. (author).
Magnetization, neutron diffraction and "1"6"6Er Moessbauer measurements on ErPd_2Si_2 are reported. Below 4.8 K ErPd_2Si_2 orders AF with complex modulated magnetic structures, where the Er moments are aligned along the c-axis. At 1.5 K a squared structure with #mu#_E_r #approx# 7.8(1)#mu#_B is found while a saturation Er moment of 8.2(2)#mu#_B is inferred from the hyperfine field data. The temperature dependence of the Moessbauer spectra in the paramagnetic region is explained in the framework of a relaxation model implying excited crystal field levels. Its analysis is used to estimate the B"m_n CEF parameters. (orig.).
The magnetic properties of diluted spinels Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Mg, Ni) systems have been studied by mean field theory, probability law and high-temperature series expansions method in the range 0 {<=} x {<=} 1. The exchange interactions are calculated by the first and second theory, respectively. The magnetic phase diagrams of Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Mg, Ni) are calculated by the high-temperature series expansions, combined with the Pade approximants method. The critical exponent associated with the magnetic susceptibility ({gamma}) is deduced.
In this study structural and magnetic character of the expanded austenite phase (gN) layer formed on a medical grade CoCrMo alloy by a low-pressure Radio-Frequency plasma nitriding process was investigated. The formation of the expanded austenite phase is facilitated at a substrate temperature near 400^oC for 1, 2, 4, 6 and 20h under a gas mixture of 60% N2-40% H2. The magnetic state of the gN layers was determined by a surface sensitive technique, magneto-optic Kerr effect (MOKE), and with a scanning probe microscope in magnetic force mode (MFM). Strong evidence for the ferromagnetic nature of the gN-(Co,Cr,Mo) phase is provided by the observation of stripe domain structures and the hysteresis loops. The ferromagnetic state for the gN phase observed here is mainly linked to large lattice ...
Magnetic characteristics of the ternary alloys TCu_2Si_2 (T = Nd, Dy, Ho, Er, and Tm) have been investigated. Magnetic susceptibility measurements were carried out between 4.2 and 150 K and in magnetic fields of 1 to 18 kOe, using a vibrating sample magnetometer. The Curie-Weiss law is followed by NdCu_2Si_2 above 30 K, by DyCu_2Si_2 and HoCu_2Si_2 above 50 K, and by ErCu_2Si_2 and TmCu_2Si_2 above 9 K. Furthermore, the Curie paramagnetic temperatures are given.
The purpose of this investigation is to show that resource to anisotropic compression along a magnetic field is not a necessary condition for star formation within large collapsing interstellar gas clouds. Although such a scenario would certainly eliminate the magnetic field and angular momentum problems associated with isotropically collapsing clouds, it is believed there is sufficient observational theoretical evidence to warrant the present study of magnetically braked, isotropically collapsing gas clouds. It is not attempted to disprove the hypothesis of anisotropic compression, but to offer instead, a reasonable alternative. Angular momentum transfer from magnetically braked, cool interstellar gas clouds of 10"2, 10"3 and 10"4 times the mass of the sun is examined. Magnetic torques acting on a contracting, rotating cloud, permeated by a frozen-in magnetic ...
The cross-over from a magnetically ordered to a non-magnetic spin liquid state has been investigated in a series of resistance measurements under hydrostatic pressures of up to 30 kbar and at temperatures down to below 200 mK in the heavy fermion antiferromagnet CePd{sub 2}Si{sub 2}. The electrical resistivity changes dramatically with increasing pressure. Near the critical pressure, at which the magnetic ordering temperature is extrapolated to zero, it exhibits a quasi-linear variation over two orders of magnitude in temperature. This non-Fermi liquid form of {rho}(T) extends down to the onset of a new superconducting transition below 430 mK. (orig.).
The cross-over from a magnetically ordered to a non-magnetic spin liquid state has been investigated in a series of resistance measurements under hydrostatic pressures of up to 30 kbar and at temperatures down to below 200 mK in the heavy fermion antiferromagnet CePd_2Si_2. The electrical resistivity changes dramatically with increasing pressure. Near the critical pressure, at which the magnetic ordering temperature is extrapolated to zero, it exhibits a quasi-linear variation over two orders of magnitude in temperature. This non-Fermi liquid form of #rho#(T) extends down to the onset of a new superconducting transition below 430 mK. (orig.).
The magnetic and magnetostrictive properties of polycrystalline Co1-xMnxFe2O4 (0 ? x ? 0.4) have been studied. Although the Curie temperature decreases continuously with increasing concentration of Mn, the magnetization remains high up to x = 0.3 and unexpectedly low coercivity is observed for this composition showing an unusual magnetostrictive behaviour. This composition shows a relatively larger magnetostriction at low fields. Moreover, the strain derivative which is the slope of the magnetostriction curve at low magnetic fields is almost doubled and the field at which maximum magnetostriction is observed is reduced to almost half for 30% of Mn substitution. The results show that x ? 0.3 in Co1-xMnxFe2O4 is an optimum composition with superior magnetostrictive properties for many applications.
We present a systematic study of the magnetization, Hall effect and specific heat on single crystals of Mn{sub 4}Si{sub 7}. Curie-Weiss law is observed above 43 K. At low-temperature moments order in an anisotropic helical state and are aligned above 1 T. We observe an anomalous Hall effect in both {rho}{sub H} vs. B and in R{sub H} vs. T curves and a field dependence of the low T specific heat due to spin fluctuations. The magnetic moments (p{sub eff} and p{sub sat}) are the lowest reported for similar itinerant magnetic systems, this suggests that Mn{sub 4}Si{sub 7} is a good candidate to observe critical quantum fluctuations expected for a marginal Fermi liquid.
The magnetic pyrochlore Er{sub 2}Ru{sub 2}O{sub 7} has been studied with neutron scattering and susceptibility measurements down to a base temperature of 270 mK. For the low temperature phase in which the Er sublattice orders, new magnetic Bragg peaks are reported which can be indexed with integer (hkl) for a face centered cubic cell. Inelastic measurements reveal a wealth of crystal field levels of the Er ion and a copious amount of magnetic scattering below 15 meV. The three lowest groups of crystal field levels are at 6.7, 9.1 and 18.5 meV.
We report electronic and magnetic structure of arsenic-doped manganese clusters from density-functional theory using generalized gradient approximation for the exchange-correlation energy. We find that arsenic stabilizes manganese clusters, though the ferromagnetic coupling between Mn atoms are found only in Mn$_2$As and Mn$_4$As clusters with magnetic moments 9 $\\mu_B$ and 17 $\\mu_B$, respectively. For all other sizes, $x=$ 3, 5-10, Mn$_x$As clusters show ferrimagnetic coupling. It is suggested that, if grown during the low temperature MBE, the giant magnetic moments due to ferromagnetic coupling in Mn$_2$As and Mn$_4$As clusters could play a role on the ferromagnetism and on the variation observed in the Curie temperature of Mn-doped III-V semiconductors.
The current paper continues the analysis of a completely novel method of fluid manipulation technology in micro-fluidics systems, inspired by nature, namely by the mechanisms found in ciliates. More information on this subject can be found at http://www.hitech-projects.com/euprojects/artic/. In order to simulate the drag forces acting on an array of artificial cilia, we have developed a computer code that is based on fundamental solutions of Stokes flow in a semi-infinite domain. The actuation mechanism consists of a bi-directional rotating excitation magnetic field. The magnetization induced by the magnetic field was calculated in a separate routine based on the Integral Nonlinear Equations Approach with 1D discretization of wire (cilium). Time averaged x-coordinate mass flow rates, strea...
These notes present a pedagogical introduction to magnetic monopoles, supersymmetry and dualities in gauge theories. They are based on lectures given at the X Jorge Andre Swieca Summer School on Particles and Fields. (author)
The magnetic properties of the superconductive materials HoBa/sub 2/Cu/sub 3/O/sub z/ and YBa/sub 2/Cu/sub 3/O/sub z/ have been measured and compared. Both had superconductive transition temperatures T/sub c/ in low magnetic fields near 90 K and exhibited nearly complete magnetic-flux exclusion. The susceptibility of the Ho-based materials followed a Curie-Weiss law both above and below T/sub c/. These results give clear experimental evidence for a nearly complete decoupling of the magnetic and superconductive layers, demonstrating that the superconductivity is highly anisotropic.
... Zinn, J., Hoerlin, H., and Petschek, AG, "The Motion of Bomb Debris Follow- ing the Starfish Test," Radiation Trapped in the Earth's Magnetic Field ...
High-field magnetization properties of single crystalline CeRh{sub 2}Si{sub 2} and CePd{sub 2}Si{sub 2} were investigated. Two-step metamagnetic transition (H{sub c1}=25.4 T and H{sub c2}=26.0 T) was observed in the case of CeRh{sub 2}Si{sub 2}, whereas no anomaly was found in the magnetization process of CePd{sub 2}Si{sub 2} up to 28 T. The mean field analysis has shown that CeRh{sub 2}Si{sub 2} is quite anisotropic compared to CePd{sub 2}Si{sub 2}, which results in the sharp contrast between the magnetization processes of the two compounds.
High-field magnetization properties of single crystalline CeRh_2Si_2 and CePd_2Si_2 were investigated. Two-step metamagnetic transition (H_c_1=25.4 T and H_c_2=26.0 T) was observed in the case of CeRh_2Si_2, whereas no anomaly was found in the magnetization process of CePd_2Si_2 up to 28 T. The mean field analysis has shown that CeRh_2Si_2 is quite anisotropic compared to CePd_2Si_2, which results in the sharp contrast between the magnetization processes of the two compounds
Heat-capacity (0.5--20 K) and magnetic-susceptibility (4--300 K) measurements have been made on two cerium sulfide samples having compositions as CeS/sub 1.393/ and CeS/sub 1.457/. These materials follow the Curie-Weiss law above 100 K, and become ferromagnetically ordered near 6 and 3 K, respectively. Shift of the ordering to higher temperatures under applied magnetic fields is also observed in CeS/sub 1.457/. The estimated effective magnetic moment and entropy associated with the ordering are consistent with the paramagnetic nature of Ce/sup 3 +/ (4f/sup 1/) in a crystalline environment.
MAGNETIC FORMING BERYLLIUM COIL ASSEMBLY. By. J. W. Rogers, D. D. Wier, and M. E. Davis. Department of Electrical Engineering. Mississippi State University ...
Ferrite of system, namely Ni_1_-_xZn_xFe_2O_4 with x = (0.0, 0.2, 0.4, 0.6, 0.8, 1.0), have been prepared by solid state reaction to investigate the effect of gamma rays irradiations using Co"6"0 source on the cation distribution, structural and magnetic properties. The unirradiated and irradiated samples were then subjected to characterization techniques such as X-ray diffraction, magnetization and AC susceptibility. The results of these characterizations are found to be different for irradiated from that of the pristine sample. The modifications in respect of irradiated samples are explained in terms of the ion-induced disorder. The important result of #gamma#-irradiation on the cation distribution, structural and magnetic properties is the change of ratio Fe"2"+/Fe"3"+. Possible reasons on the results are proposed.
We analyzed ionospheric observations made with digisondes in Jicamarca, Ramey, Wallops Island, Ascension Island, and Kwajalein Island during the major magnetic storm of November 9-10, 2004, which was associated with rapid interplanetary magnetic field (IMF) Bz changes. The strongest ionospheric responses to the southward IMF Bz turning were observed at the dip equator at Jicamarca where during the magnetic disturbance a dramatic F2 peak density depletion occurred at around 15:00 local time, accompanied by a fast upward motion of the plasma. In this process, an additional ionospheric layer, the F3 layer, formed with peak densities NmF3 exceeding NmF2. This observation may be considered evidence of an equatorial plasma fountain enhancement caused by the magnetic field disturbance. Responses ...
The galvanomagnetic properties of single-crystal samples of the Bi{sub 0.93}Sb{sub 0.07} semiconductor alloy with the electron density n = 1.6 x 10{sup 17} cm{sup -3} in magnetic fields up to 14 T at T = 1.6 K have been investigated. The resistivity {rho} and Hall coefficient R have been measured as functions of the magnetic field directed along the binary axis of a crystal for a current flowing through a sample along the bisector axis; i.e., the components {rho}{sub 22} and R{sub 32,1} have been measured. The strong anisotropy of the electron spectrum of the samples makes it possible to separately observe quantum oscillations of the magnetoresistance {rho}{sub 22}(H) for H -parallel C{sub 2} in low magnetic fields for two equivalent ellipsoids with small extremal cross sections (secondary ellipsoids) and in high magnetic fields for electrons of the ellipsoid with a large extremal cross section (main ...
By ab-initio calculation we show that the (Ga,Fe)N ground state may be changed from anti-ferromagnetic to ferromagnetic by acceptor defect like Ga vacancies. The electronic structures are calculated by using the Korringa-Kohn-Rostoker (KKR) method combined with coherent potential approximation (CPA). We show that we can increase the magnetic moment of Fe in p-type GaN by oxygen co-doping. Mechanism of exchange interactions between magnetic ions in p-type (Ga,Fe)N is also studied. The effect of external magnetic field on the electronic structure of (Ga, Fe)N and p-type (Ga, Fe)N is investigated.
We investigate the effects of the velocity-dependent force on the magnetic form factors and magnetic moments of odd-Z nuclei. The form factors are calculated with the harmonic-oscillator wavefunctions. It is found that the contributions of the velocity-dependent force manifest themselves in the very large momentum transfer region (q?4 fm-1). In the low and medium q region the contributions of the velocity-dependent force are very small compared with those without this force. However, in the high-q region the contributions of the velocity-dependent force are larger than the normal form factors. The diffraction structures beyond the existing experimental data are found after the contributions of the velocity-dependent force are included. The formula of the correction to the single particle magnetic moment due to the velocity-dependent force is reproduced exactly in the long-wavelength limit (q=0) of the M1 form factor. ...
SOME SCIENTISTS ALLEGE that exposure to electric and magnetic fields generated by electric power delivery systems is responsible for certain cancers (particularly among children), reproductive dysfunction,...Full Text Available
A new magnet power supply system for J-PARC 50GeV Synchrotron is proposed as solutions both in the power capacity and in the precision at the same time. The developed 10MW class magnet power supply consists of the advanced self-commutated current-source type converter (ACSC) using the new device IEGT rated at 4500V-2100A and the ''hybrid filter'' including the variable impedance filter with the equivalent 16 kHz switching. With 1/16 scale-model system using a prototype bending magnet, the experimental results showed the current ripple less than 1 x 10"-"6 and the tracking error less than #+-#0.5 x 10"-"4. (author)
To study the nanoscale electronic order in strongly correlated electron systems and vortex states in high-Tc superconductors in high magnetic fields, we have developed scanning tunneling microscopy (STM) for the 18 T cryocooled superconducting magnet (18T-CSM). The test results of the STM operation in the 18T-CSM at room temperature indicate that our STM has a good atomic resolution up to 18 T when we use the nonmagnetic vibration-isolation table which reduce the vibration noise from the cryocoolers of the 18T-CSM. In this paper, we report on the design of the high-field STM system for large-scale magnets and its performance.
We report the first band structure calculations of the quasi-one-dimensional [MnTPP][TCNE] compounds (TPP?=?meso-tetraphenylporphyrinato, TCNE?=?tetracyanoethylene), based on Density Functional Theory (DFT) methods, in order to interpret the magnetic ordering in these prototypic systems. We compare and contrast the results of broken-symmetry DFT calculations for extended systems, with periodic boundary conditions, and for finite systems, magnetic dimers modeling the actual molecular magnets. By varying systematically the main angles, we are able to determine the geometry dependence of the exchange interaction. Structure?properties correlations in these charge-transfer salts reveal the determinant role of the Mn-(N?C)TCNE bond angle on the strength of the ferrimagnetic coupling between the ...
The crystal structure of R/sub 6/Cu/sub 8/Sn/sub 8/ compounds (R=Gd, Tb, Dy, Ho, Er, Tm) is determined and their magnetic susceptibility is measured in the temperature range 78-293 K. The structure of the compounds is isotypical with the Gd/sub 6/Cu/sub 8/Ge/sub 8/ type (space group Immm, Z=1). The magnetic susceptibility of the R/sub 6/Cu/sub 8/Sn/sub 8/ compounds is described by the Curie-Weiss law. Effective magnetic moments of R/sub 6/Cu/sub 8/Sn/sub 8/ compounds (R=Gd, Tb, Dy, Ho, Er, Tm) are in good agreement with theoretical values for free R/sup 3 +/ ions.
Propagation of an intense charged particle beam pulse through a background plasma is a common problem in astrophysics and plasma applications. The plasma can effectively neutralize the charge and current of the beam pulse, and thus provides a convenient medium for beam transport. The application of a small solenoidal magnetic field can drastically change the self-magnetic and self- electric fields of the beam pulse, thus allowing effective control of the beam transport through the background plasma. An analytic model is developed to describe the self-magnetic field of a finite- length ion beam pulse propagating in a cold background plasma in a solenoidal magnetic field. The analytic studies show that the solenoidal magnetic field starts to infuence the self-electric and self-magnetic fields when ?ce > ?pe?b, where ?ce = e?/mec is the electron gyrofrequency, ...
Magnetic fields appear to be a generic feature of the early universe and are a natural source of secondary CMB non-Gaussianity. In recent years the statistical nature of the stresses of a primordial magnetic field has been well studied. In this paper we confirm and extend these studies at one- and two-point level, and present analytical results for a wide range of power-law spectra. We also consider two non-power law cases of interest: a blue spectrum with an extended damping tail on small scales, which could be generated by the non-linear mixing of density and vorticity; and a red spectrum with a damping tail on large scales. We then briefly consider the CMB impacts that result from such fields. While this paper focuses on the one- and two-point moments, the techniques we employ are designed to ease the analysis of the full bispectra induced by primordial magnetic fields.
The collapse and fragmentation of initially prolate and oblate, magnetic molecular clouds is calculated in three dimensions with a gravitational, radiative hydrodynamics code. The code includes magnetic field effects in an approximate manner: magnetic pressure, tension, braking, and ambipolar diffusion are all modeled. The parameters varied for both the initially prolate and oblate clouds are the initial degree of central concentration of the radial density profile, the initial angular velocity, and the efficiency of magnetic braking (represented by a factor f _m_b = 10"-"4 or 10"-"3). The oblate cores all collapse to form rings that might be susceptible to fragmentation into multiple systems. The outcome of the collapse of the prolate cores depends strongly on the initial density profile. Prolate cores with central densities 20 times higher than their boundary densities collapse and fragment into ...
A classical model is presented for magnetic field-induced Wigner crystallization in electron systems confined within two-dimensional quantum dots. In contrast to other classical models, this one does not treat an electron as a point charge; the electron density is assumed to take a Gaussian form corresponding to the lowest Landau level. Using a Monte Carlo method we have determined the equilibrium configurations as functions of the magnetic field. We have found a classical counterpart of the quantum maximum density droplet (MDD) and studied the breakdown of the MDD into a Wigner molecule as well as the transformations of the Wigner molecule shape induced by the external magnetic field. The phase diagram for the classical Wigner molecules has been presented and its qualitative agreement with previous quantum mechanical calculations has been shown.
High Cycle Fatigue Initiative Workshop -Active Vibration. Control/Engine. Health Monitoring Session December 10,. 1996. The presentation was titled "Active ...
High gradient magnetic separation (HGMS) of magnetic materials from fluids or waste products has many established industrial applications. However, there is currently no technology employing HGMS for ex-vivo biomedical applications, such as for the removal of magnetic drug- or toxin-loaded spheres from the human blood stream. Importantly, human HGMS applications require special design modifications as, in contrast to conventional use where magnetic elements are permanently imbedded within the separation chambers, medical separators need to avoid direct contact between the magnetic materials and blood to reduce the risk of blood clotting and to facilitate convenient and safe treatment access for many individuals. We describe and investigate the performance of a magnetic separator prototype designed for biomedical applications. First, the capture efficiency of a ...
Magnetite nanoparticles with high self-heating capacity and low toxicity characteristics are a promising candidate for cancer hyperthermia treatment. In order to achieve minimum dosage to a patient, magnetic nanoparticles with high heating capacity are needed. In addition, the influence of physiological factors on the heat capacity of a material should be investigated in order to determine the feasibility. In this study, magnetite nanoparticles coated with lauric acid were prepared by co-precipitation of Fe{sup 3+}:Fe{sup 2+} in a ratio of 2:1, 5:3, 3:2, and 4:3, and the pH was controlled using NaOH. Structural and magnetization characterization by means of X-ray diffractometry (XRD) and a superconducting quantum interference device (SQUID) revealed that the main species was Fe{sub 3}O{sub 4} and further showed that most of the nanoparticles exhibited superparamagnetic properties. All of the magnetic nanoparticles showed a ...
Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available
Effect of low-frequency pulsating magnetic field on the microstructure and magnetic properties of amorphous alloy Fe{sub 78}Si{sub 9}B{sub 13} were investigated. The temperature rise induced by the treatment was measured by a non-contact infrared thermometer. The crystallization behavior and microstructure of specimens were studied by Moessbauer spectroscopy and transmission electron microscope (TEM). Magnetic properties of the specimens were investigated by alternating gradient magnetometer (AGM). The results show that the low-frequency pulsating magnetic field can promote the single-phase crystallization of amorphous alloy Fe{sub 78}Si{sub 9}B{sub 13}. The frequency, f of applied field is from 10 to 40 Hz, magnetic field, H is from 0.02 to 0.04 T and treatment duration, t is from 180-300 s. The volume fraction of crystallization phase ({alpha}-Fe(Si), the grain size, 2-10 nm) is ...
Based on proposed models for the tidal spin-up and magnetic braking of stars with a convective outer envelope, it is suggested that the rotation of secondaries in cataclysmic variables is not necessarily synchronized with the orbital revolution. This may provide an explanation for the observed large range in the mass transfer rate (at the same orbital period) of cataclysmic variables above the period gap. (author).
Using the Relativistic Mean Field Theory (RMF) it is shown that different proton fraction which is directly connected with the neutron excess and with the asymmetry of the system affects proto-neutron stars parameters and changes their composition. The obtained form of the equation of state allows to construct the mass-radius relations and shows that the increasing asymmetry creates more compact stars. The inclusion of {delta} meson together with nonlinear vector meson interaction terms and magnetic field make this effect even stronger.
The thermal decrease of the order parameter can empirically be described by a single T{sup {epsilon}} power law with an exponent {epsilon} which depends on the dimensionality of the magnetic interactions and on whether the spin quantum number is integral or half-integral. We present experimental examples in which the order parameter shows a crossover between different T{sup {epsilon}} power laws as a function of temperature. This indicates that the magnetic interactions can change their dimensionality as a function of temperature. (orig.)
The author examines the place of tachyons and magnetic monopoles in the 'projective relativity' theory, which is based on the De Sitter universe and which has special relativity as a limiting case. A link with a generalized form of Maxwell's equations is examined in detail, the connection being through the rotation group R_5. (W.D.L.).
The experimental superconducting magnetic system of 0.5 MJ energy storage is described. The step variation of the winding inductance provides a control by the discharge current at the energy output on a high-ohmic load. The voltage on a load is 45 kV at the current 1100 A under the controllable discharge conditions. The energy transfer coefficient constitutes 0,76 under the maximum-to-minimal current ratio equal to 1.3. 7 refs., 3 figs., 2 tabs.
A method for estimating the form of magnetic nanoparticles in composite film structures based on the observation of ferromagnetic resonance phenomenon is offered. Within the model of the effective medium, an explanation is given for experimentally observed concentration and temperature dependences of resonant fields for composite nanosystem (Co45Fe45Z10) f +(Al2O3)100?f .
Pacini (1973) has considered basic theoretical expectations regarding the magnetic dipole radiation and unipolar induction of pulsars, taking into account observational results. The present investigation is concerned with the difference between the two braking mechanisms. Attention is also given to a statistical study involving a comparison of the two braking mechanisms with observations. The study makes use of the observational data for the distribution of apparent beamwidth, and a geometrical method. The obtained results agree with the theory of magnetic dipole radiation.
In Ce(Ru{sub 1-x}Pd{sub x}){sub 2}Si{sub 2} the dilution of the transition metal leads to strong electronic effects resulting in the disappearance and the appearance of long-range magnetic order in CePd{sub 2}Si{sub 2} and CeRu{sub 2}Si{sub 2}, respectively. ((orig.)).
In Ce(Ru_1_-_xPd_x)_2Si_2 the dilution of the transition metal leads to strong electronic effects resulting in the disappearance and the appearance of long-range magnetic order in CePd_2Si_2 and CeRu_2Si_2, respectively. ((orig.)).
The synthesis of a new kind of magnetic, fluorescent multifunctional nanoparticles (~30 nm in diameter) was demonstrated, where multiple fluorescent CdTe quantum dots (QDs) are covalently linked...Full Text Available
A physical model of free-electron laser (FEL) amplifier with variable-parameter wiggler magnets for one-dimensional numerical simulation is presented and a numerical example is given. The wiggler parameters, efficiency of energy conversion between electron beam and laser field, laser intensity, phase-space distributions and energy spectrum of electrons are computed. The period of synchronous oscillation and saturation value of laser intensity agree with estimated one.
Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5f electrons. (author).
Nuclear magnetic resonance results are presented for a number of NaCl-type compounds and cubic Laves-phase type compounds of uranium, neptunium, and plutonium. Special emphasis is placed on the Knight shift and spin-lattice relaxation time measurements and their interpretation in terms of localized or itinerant pictures of the 5Line integral electrons.
Negative ion intensities of over 3 x 10/sup 5/ A/m/sup 2/ at energies of 2 MeV have been measured in a magnetically insulated transmission line. This negative ion production can affect the power flow in multiterawatt pulsed power devices, and may also have applications in the generation of high-intensity neutral or negative ion beams.
A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available
The thickness dependent magnetic properties of artificially prepared ultrathin body-centered cubic Ni films have been explored using the all electron full potential linearized augmented plane wave (FLAPW) method. We have considered two types of BCC Ni(001) films: (i) pure BCC Ni(001) and (ii) Au capped BCC Ni(001) in the range from 1 monolayer (ML) to 4 ML of Au capping coverage. The average magnetic moment of pure BCC Ni(001) is about 0.63 #mu#_B and a typical surface enhancement is found with a magnetic moment of 0.78 #mu#_B. In the presence of an Au capping layer, the magnetic moment of interface Ni is strongly suppressed to approximately 0.5 #mu#_B and this causes a reduction of average magnetic moment. Nevertheless, the Au adlayer has no meaningful induced magnetic moment. The BCC pure Ni(001) films always have in-plane magnetization up ...
The macroscopic behavior of magnetostrictive materials results from domain evolutions occurring at a microscopic scale. The author shows how to compute magnetization and magnetostriction curves by appraising the behavior of the underlying microstructures. The method hinges on an averaging device (Young measures), which allows one to pass from the microscopic to the macroscopic scale. He takes into account the kinematical constraints on the accommodation of elastic effects, and he highlights the role of material symmetry in the selection of energetically optimal microstructures.
We reviewed retrospectively the magnetic resonance (MR) images of 14 soft-tissue lesions of fibromatosis (desmoid tumors) encountered in 11 patients. The lesions were typically inhomogeneous in texture and round to oval in configuration. Margins were well-defined in 78% of the lesions at presentation and were infiltrating in all recurrences. (orig./DG).
The magnetic excitations of the Kondo compound CePd_2Si_2 below its Neel temperature (T_N = 10 K) have been studied by inelastic neutron scattering. At T = 1.6 K the data are best represented by two dispersive inelastic modes. Their linewidth (#propor to# 0.5 meV) indicates substantial broadening, which is ascribed to Kondo-type local fluctuations. (orig.).
The compound UC_2Si_2 has been found to be ferromagnetic at low temperatures with a Curie temperature of 101"0K. The magnetization follows a Curie-Weiss law in the paramagnetic region with an effective magneton number of 2.12 Bohr magnetons per uranium atom. Partial substitution of Th atoms for the U atoms results in an expansion of the lattice, a rapid drop in the Curie temperature, and a sizable increase in the coercive field.
We examine the electric and magnetic strange form factors of the nucleon in the pseudoscalar-vector SU(3) Skyrme model, with special emphasis on the effects of isospin symmetry breaking (ISB). It is found that ISB has a nontrivial effect on the strange vector form factors of the nucleon and its contribution to the nucleon strangeness is significantly larger than one might naively expect. Our calculations and discussions may be of some significance for the experimental extraction of the authentic strangeness.
We examine the electric and magnetic strange form factors of the nucleon in the pseudoscalar-vector SU(3) Skyrme model, with special emphasis on the effects of isospin symmetry breaking (ISB). It is found that ISB has a nontrivial effect on the strange vector form factors of the nucleon and its contribution to the nucleon strangeness is significantly larger than one might naively expect. Our calculations and discussions may be of some significance for the experimental extraction of the authentic strangeness.
Using the experimentally determined cutoff energies of the muon-electron and the pion-electron conversion curves in a tachyon-bradyon model of the electron and the muon, the magnetic moments of these particles have been derived and found to be the Bohr magnetons identically. The tachyons, being bound to the bradyons and unable to drop below the speed of light, cause the bradyons to revolve in an orbit. It is this orbital motion of the charged bradyons that generates the magnetic moments.
Single crystals of U(Ni_1_-_xPd_x )_2Si_2 for x = 0.05, 0.10 and 0.15 have been grown. Magnetization and electrical resistivity measurements were performed in a wide range of temperatures, magnetic fields and high pressures in order to study stability of magnetic phases in the solid solutions between UNi_2Si_2 and UPd_2Si_2 with a special emphasis on the type of ground state. In UPd_2Si_2 the simple AFI-type antiferromagnetic structure of U moments is observed at low temperatures. UNi_2Si_2 adopts the uncompensated AF structure (UAF) with the ++- stacking of U moments along the c-axis and consequently this compound exhibits a spontaneous magnetization corresponding to 1/3 of the U moment. The substitution of Pd for Ni leads to a rapid decay of the spontaneous magnetization. The evolution of magnetization and electrical resistivity behavior with Pd doping is ...
Magnetic field, thickness and magnetic forming effect on general mode and quantitative parameters of the domain structure (DS) of ferrite-garnet (EuEr)/sub 3/(FeGa)/sub 5/O/sub 12/ monocrystalline plates (111) is investigated. Field interval of circle (cone) and ring domain stability is determined. It is shown that DS of ferrite-garnet crystals with uniaxial an6sotropy has some peculiarities, that can be explained by cubic anisotropy effect.
The motivation for this design study has been to identify magnet designs for useful magnetic fusion experiments which minimize capital cost. Some possibly useful novel design features have been identified. 5 refs., 6 figs., 3 tabs.
The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.
BackgroundCardiovascular magnetic resonance (CMR) allows volumetric carotid plaque measurement that has advantage over 2-dimensional ultrasound (US) intima-media thickness (IMT)...Full Text Available
A previous study described the basic theoretical expectations of the magnetic dipole radiation and unipolar induction of pulsars and presented observational results. This paper further discusses the difference between the two braking mechanisms and analyses the results of a statistical study through observed data of apparent beamwidth's distributions and a geometrical method. The theory of magnetic dipole radiation of pulsars agrees with the observations. Unipolar induction as a braking mechanism is not consistent with the observations.
A new, magnetically insulated negative ion source has recently been discovered which can produce pulsed negative ion beams (H/sup -/, Li/sup -/, and C/sup -/) with intensities of 100-300 A/cm/sup 2/ at 1-4 MeV. This source may provide the basis for a high energy neutral beam system for heating large tokamaks.