The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early ...
MRI, ultrasonography and angiography were performed on 24 cases with small renal cell carcinoma, and data were compared with pathological architecture type. An average diameter of cancer was 20.8 mm (10-30 mm). Each tumor was pathologically classified into four architecture types: alveolar type (15 cases), papillary type (5 cases), tubular type (3 cases) and cystic type (1 case). In comparison with renal cortex alveolar type renal cell carcinoma showed equal or low signal in T1-weightedimages and equal or high signal in T2-weightedimages. Papillary and tubular types showed high signal in T1-weightedimages, and low signal in T2-weightedimages. In alveolar type, many cases showed equal echo in ultrasonography and hypervascularity in ...
We present a case of cerebral aspergillosis in an immunocompetent patient. The MRI signal characteristics were compared with the histologic findings. Irregular low-signal zones were demonstrated between the wall of the abscess and the central necrosis on T2-weightedimages; the pathology specimen revealed concentrated iron in these transitional zones but no hemosiderin. Iron is an essential element for the growth of fungal hyphae. The low-signal zones may represent the areas where there was active proliferation of aspergillus, and the unique location of the low signal may be a helpful imaging characteristic for the diagnosis of an aspergillus abscess. (orig.)
Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and ...
This study was designed to evaluate early parenchymal changes of acute cerebral is chemia/infarct by using T2-weighted, diffusion-weighted, and calculated apparent diffusion coefficient(ADC) MR imaging. The brain MR images were successfully obtained 30, 60, 90, 120, 150 and 180 minutes after intraarterial administration of Lipiodol (0.4-0.6ml) into the common carotid artery in 10 of 11 cats (91%). T2-and diffusion-weightedimages and ADC were analyzed and compared with histopathologic findings. High signal intensity on T2-weighted and diffusion-weightedimages was found in one cerebral hemisphere 30 minutes after Lipiodol injection, which tended to increase with time until 3 ...
To investigate the pattern of normal white-matter maturation as demonstrated by high-field-strength MR imaging, 82 normal infants were examined using a 1.5-T unit with spin-echo T1-weighted and T2-weighted pulse sequences. The infants ranged in age from 4 days to 2 years. The scans were assessed for qualitative changes of white matter relative to gray matter and correlated with the patient's age in 14 anatomic areas of the brain. The MR images showed that changes of brain maturation occur in an orderly manner, commencing in the brain stem and progressing to the cerebellum and the cerebrum. Changes from brain myelination were seen earlier on T1-weightedimages than on T2-weightedimages, possibly because of T1 shortening by the components ...
The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach ...
Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weightedimages and in the brain stem by MRI. (orig.).
A four-stage scoring system for brain maturation was established with MR imaging. First, gyration and myelination were analyzed in 50 anamnestically normal children (32-240 weeks postconceptional age). Subsequently 60 patients (same age range) with birth asphyxia, seizures, or developmental delays were evaluated analogously. T1- and T2-weightedimages (500/30 and 3,000/120 [repetition time msec/echo time msec]) were obtained with a 2.35-T magnet in all children. Whereas gyration abnormalities were seen in some patients, all handicapped children presented with delayed myelination. In conclusion, prospective staging of brain development (gyration and myelination) is possible and is best obtained with T2-weightedimages.
Paroxysmal nocturnal hemoglobinuria (PNH) is a rare, acquired disease involving multiple hematopoietic cell lines. Characteristics of PNH are intrinsic hemolytic anemia, iron deficiency anemia and venous thrombosis. We report a case of PNH with characterostoc MR and CT findings. The signal intensity of renal cortex was lower than that of medulla on both T1-and T2-weighted MR imaging. On T2weighted MR images, the liver showed very low signal intensity but the signal intensity of the spleen was normal. On precontrast CT the attenuation of renal cortex was higher than that of renal medulla and the attenuation of liver was higher than that of the spleen. These findings of MR imaging and CT were the result from the deposition of hemosiderin in the cells of proximal convoluted tubules and transfusional ...
This paper reports, to complement current knowledge on brain development, late regional brain maturation assessed with quantitative MR imaging. Axial and coronal head spin-echo (SE) images were obtained in 60 healthy individuals aged 5--56 years, with a double-echo, flow compensated imaging sequence obtained with a 1.5-T Magnetom spectroscopy and imaging system. T2-weightedimages were calculated from the intensity differences in SE images at echo times (TEs) of 15 and 90 msec (TR = 2.5 second). The mean T2 values were determined at 16 sites in each cerebral hemisphere. T2 values of the six frontal subcortical white matter (FSCWM) sites and of the internal capsule (IC) were evaluated. Mean ...
We report the delayed sequelae arising in a case of electrical injury, reviewing the literature on the subject and focusing on the MRI findings of the brain. A 23-year-old male suffered burns to the left parietal scalp, both feet, and the anterior chest wall. Neurological symptoms and MRI abnormalities appeared 14 days after the insult and continued for about three months. T1-weight MR images demonstrated homogeneous hypointensity, while T2-weightedimages depicted hyperintense finger-like projections. Contrast-enhanced T1-weightedimages demonstrated strong band-like enhancement, indicating meningeal hyperemia. Follow-up MR imaging showed that the lesion had disappeared, indicating that the cerebral edema and meaningeal hyperemia were reversible.
Sixty-six cases of histologically proven hepatocellular carcinomas (HCC) were studied by MRI. Detectability was better by MRI than by CT, especially in the tumor under 2 cm in diameter. The capsule was detected in all cases of HCC over 3 cm in diameter. The capsule was able to be diagnosed only by dynamic MRI study in some cases. High intensity on the T1-weightedimage and iso or low intensity on the T2-weightedimage suggested that the nodule was adenomatous hyperplasi (AH) or well differentiated HCC. MRI is concluded to be an essential modality in the diagnosis of HCC. (author).
Purpose: To evaluate a T_2-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T_2-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR_e_f_f/T_E/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis ...
Six patients with eosinophilic granuloma were studied retrospectively in order to correlate the MRI appearances with the pathology. Ages ranged from 2 years 6 months to 11 years. The bones involved were the humerus, ulna, radius, femur, clavicle and ilium. Plain films, MRI and pathology specimens were obtained. A lytic lesion with indistinct margins, endosteal erosions and periosteal reaction was seen in all cases on plain radiographs. Bone marrow signal was decreased on T1-weightedimages and increased on T2-weightedimages throughout the bony lesion in all cases. T2-weightedimages showed extensive soft-tissue abnormalities suggesting inflammatory changes in four cases. In two cases abnormalities were limited. Extensive changes correlated histologically with an early phase ...
Magnetic resonance imaging (MRI) was used to evaluate 22 histological proven peripheral nerve sheath tumors, approximately two-thirds of which arose in the lower extremity. The histologic distribution was as follows: 12 schwannomas, 7 neurofibromas, and 3 malignant peripheral nerve sheath tumors (2 of which occurred in patients with neurofibromatosis). Most lesions demonstrated an intermediate to moderately bright signal on T_1-weightedimages and were minimally inhomogeneous. All lesions were moderately bright on T_2-weightedimages, again with variable inhomogeneity. The extent of the tumor was best assessed on proton-density- and T_2-weightedimages. Smooth margins were noted in 19 lesions. Of the 3 remaining lesions, 2 were malignant (but had been ...
Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...
Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weightedimages were easily detected by Gd-DTPA scans. ...
We report a 20-year-old woman who suffered headaches before presenting with a state of fluctuating vigilance. MRI showed diffuse high signal in the basal ganglia bilaterally on diffusion- and T2-weightedimages, which had areas of both low and high apparent diffusion coefficient, presumed to correspond to cytotoxic and vasogenic oedema. MR venography showed no flow in the deep cerebral veins or straight sinus. Heparin was given, with clinical recovery. On follow-up MRI, the appearances became normal. (orig.)
Objective: To analyze the characteristics of external hydrocephalus in infancy with MR imaging, and to explore the cause of accumulation of extracerebral fluid and the relation with brain development. Methods: Conventional magnetic resonance T_1 weightedimaging (T_1WI) and T_2weightedimaging (T_2WI) were performed in 46 infants aged 2 years or younger with external hydrocephalus (EH), and the results were analyzed. They were divided into 7 age groups. The width of extractable space was measured on T_2WI and compared with normal standard. Results: EH mainly resulted from infection, subdural hematoma or subarachnoid hemorrhage, HIE, which were 67.4% (31/46 cases) of the cases; EH with unknown cause were 26.1% (12/46 cases). EH was mainly located at the ...
Objective: To compare the histopathology of nodular fasciitis (NF) with the magnetic resonance imaging (MRI) findings in order to evaluate the basis of the MR signal characteristics. Design and patients: Ten patients with NF, nine females and 1 male, with an age ranging from 13 to 58 years (mean 26.8 years) were studied. MRI findings, available in all 10 patients, were compared with the histopathology in nine patients, and an area-to-area comparative study of the whole specimen section histopathology and MRI was performed in two patients. Results: On the basis of an excisional biopsy or resection specimen, the nine lesions were classified into myxoid (n=4), cellular (n=3) and fibrous (n=2) subtypes. Four myxoid lesions with a subcutaneous location showed a homogeneous SI comparable with muscle on T1-weightedimages, high SI on T2-weighted ...
The MRI and CT appearances in 48 patients with histologically confirmed benign and malignant pleural abnormalities were compared retrospectively. Abnormal pleural changes were shown in 47 out of the 48 patients by high signal intensity of the pleura in T_2-weighted sequences and in contrast enhanced T_1-weighted sequences on MRI. CT showed abnormalities in 45 out of 48 patients. Delineation of pleural and pulmonary changes by CT was possible in 13 out of 23 cases, and pleural disease from effusions in 15 out of 28 cases. T_2-weighted MRI was successful in 14 out of 23 and 4 out of 28 cases, respectively. T_1-weightedimages after contrast were successful in 20 out of 23 and 22 out of 28 cases, respectively. Indications of malignant pleural disease were the presence of mediastinal or circumferential ...
Summary Status epilepticus or other brain-damaging insults launch a cascade of events that may lead to the development of epilepsy. MRI techniques available today, including T2- and T1-weightedimaging, functional MRI, manganese enhanced MRI (MEMRI), arterial spin labeling (ASL), diffusion tensor imaging (DTI), and phase imaging, can detect not only damage caused by status epilepticus but also plastic changes in the brain that occur in response to damage. Optimal balance between damage and recovery processes is a key for planning possible treatments, and noninvasive imaging has the potential to greatly facilitate this process and to make personalized treatment plans possible.
The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for ...
MRI findings in 13 patients with monolateral parotid tumor were compared with US, sialographic and CT findings. MRI did not allow an accurate diagnosis in 2 patients with diffuse chronic parotitis. MRI was superior to CT in 1 case in defining the intraglandular site of the lesion, and in 2 patients in showing the extraglandular involvement. MRI proved to be superior to CT thanks to its contrast resolution and to multiplanar imaging. MRI high contrast resolution made it possible to demonstrate neoplastic lesions of 4 mm in diameter. The lesion has low signal intensity on T1-weightedimages and high signal intensity on T2-weighted. Parotid tumors cannot be characterized by signal intensity alone: only morphology allows to discriminate between benign and malignant lesions. To conclude, US is a screening method, while MRI is helpful in detecting multifocal lesions ...
In 15 patients (16 hip joints) we found the clinical and radiological signs of BMOS. On T1-weighted MRI images areas of low signal intensity could be observed in the head, neck and the intertrochanteric region of the femur in various extensions. These areas showed a significant increase in signal intensity on the T2-weightedimages. Because pain was resistant to conservative therapy all these patients were treated by core decompression of the femoral head in a prospective study. Bone cores were evaluated histologically using undecalcified sections and quantitative microradiography. The existence of intramedullary oedema in exactly the regions exhibiting the MRI pattern of bone marrow oedema was verified histologically; however, bone and marrow changes similar to those of early avascular necrosis (AVN) were also visible. (orig.)
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases ...
Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T_2-weighted spin echo (SE) images as well as T_1-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 ...
Normal fetal brain maturation can be studied by in vivo magnetic resonance imaging (MRI) from the 18th gestational week (GW) to term, and relies primarily on T2-weighted and diffusion-weighted (DW) sequences. These maturational changes must be interpreted with a knowledge of the histological background and the temporal course of the respective developmental steps. In addition, MR presentation of developing and transient structures must be considered. Signal changes associated with maturational processes can mainly be ascribed to the following changes in tissue composition and organization, which occur at the histological level: (1) a decrease in water content and increasing cell-density can be recognized as a shortening of T1- and T2-relaxation times, leading to increased T1-weighted and decreased ...
Lipiodol Ultra-Fluid (Lipiodol) is widely applied in the transcatheter arterial embolization (TAE). We studied signal intensity, the T1 relaxation time and the T2 relaxation time of Lipiodol itself using Siemens Magnetom H15-2 T (1.5 Tesla) and Magnetom M10 (1.0 Tesla). Lipiodol showed higher signal intensity than saline solution on the T1-weightedimages (short TR, short TE technique in spin echo method). On the T2-weightedimages (long TR, long TE technique in spin echo method), Lipiodol showed lower signal intensity than saline solution. The T1 relaxation time of Lipiodol, measured at 1.0 T, was 201 msec and 218 msec at 1.5 T. The T2 relaxation time of Lipiodol, measured at 1.0 T, was 127 msec; and 167 msec at 1.5 T. The signal intensity of Lipiodol at 1.0 T was higher than ...
We present two cases of fetal neck masses that were initially diagnosed by ultrasound and further evaluated with prenatal MRI. MRI findings aided in further delineating the neck masses, increasing confidence in the final diagnosis (cervical teratoma and cystic hygroma). With the fetal airway typically filled with fluid that is of high signal on T2-weighted sequences, MRI images in three planes could identify whether the fetal larynx and trachea were partially or completely compressed by the neck tumor. This information was particularly useful in determining if a controlled delivery such as ex utero intrapartum treatment (EXIT) was necessary and aided the surgeons in planning their approach to establishing airway control in the delivery room. (orig.)
To assess the utility of magnetic resonance (MR) imaging in the study of pediatric patients with clinical suspicion of pituitary disease. We studied 18 patients aged 7 to 18 years.Fifteen had hormonal disturbances, two presented amenorrhea and 1 complained of headache, fever and symptoms of polyuria and polydipsia. All the patients were examined using a Siemens SP 42 1-Tesla MRI scanner. Sagittal and coronal T1-weighted spin-echo images were obtained; in addition T2-weighted spin-echo or fast spin-echo imaging was performed in ten cases and intravenous gadolinium was administered in nine. We found 9 patients with hypothalamic-pituitary dysgenesis, 2 with germinoma, 2 cases of pituitary hemosiderosis in patients with thalassemia, 2 cases of microadenoma, one abscess, one case of idiopathic central diabetes insipidus and one of Langerhans cell ...
This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further ...
Intramuscular hermorrhage was induced by injecting autologous blood into the paraspinal muscle of 8 rabbits. In order to evaluate the time-dependent changes of hemorrhage observed on MRI, the animals were imaged at different stages of blood resolution at 0.02 tesla (T), and control examined with ultrasound using a 7.5 MHz linear transducer. Six inversion recovery sequences (TR=1 000 ms. TE=30 ms, and TI=18, 48, 148, 201, 302, and 398 ms) were used for the invivo calculation of T1 relaxation times. IR 1 000 (398)/30 imaging was performed before and after the Gd-DOTA administration. The hemorrhage was evident on MR images throughout the study, especially on the T2weighted (SE 1 000/100) images. MRI showed the healing lesion longer than ultrasound. The T1 relaxation time increased during the time of resolution. Lesions on days 4 to 7 enhanced ...
The purpose of this study was to correlate MR imaging findings with pathology in experimental hyperoxia-induced acute lung injury, which has similar pathology to diffuse alveolar damage (DAD). Seventeen Yorkshire pigs were studied. These animals were exposed to more than 80% oxygen for 24, 48, 72, and 96 hours in a sealed cage. The lungs were removed and inflated with air infused through the trachea, and then examined by both MRI and high-resolution CT (HRCT). T1-weighted spin-echo (T1WSE), T2-weighted fast (T2WFSE), and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences were performed. Severity in MR findings and signal-to-noise ratios (SNR) on MR images were well correlated with pathological scores. CT values were also correlated well with pathologic scores. Abnormal SNR values were obtained from a ...
T_2weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good ...
A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T_1- and T_2-weightedimages. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG).
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI ...
The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent surgical procedures. One ...
Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weightedimages and decreased signal on T2-weightedimages with no evidence of cystic degeneration. A group of 22 preterm ...
Leukodystrophies are inherited white matter diseases due to abnormalities occurring in myelin synthesis and/or maintenance. The most common types of these rare childhood conditions are represented by adrenoleukodystrophy, metachromatic leukodystrophy, Canavan's, Alexander's, Krabbe's, and Pelizaeus-Merzbacher's diseases. Most of them are lethal during childhood, with the exception of the adrenoleukodystrophy-adrenomyeloneuropathy complex, which sometimes, during its early phases, may be cured with a dietary therapy. The aims of this paper are: 1) the description of inheritance factors, pathogenesis, pathological and clinical findings of each of the most frequent childhood leukodystrophies; 2) the description of the most common patterns of these conditions on CT and MR imaging; 3) the evaluation of the diagnostic capabilities of these two imaging techniques and the comparison of their results. Finally, some of the therapies suggested for the ...
Problems and solutions in the diagnosis and operative treatment were clarified by retrospective evaluation of cases of intramedullary tumor in which MRI and surgery had been performed. The subjects were 16 patients (21-75 years old, mean age: 45 years) whose tumor was surgically removed between 1991 and 1998. MRI was performed preoperatively, and T1-weightedimages, T2-weightedimages, and enhanced images were obtained. Angiography was also performed in some cases. The histological diagnosis based on the MRI findings before surgery were compared with the pathological diagnosis after the operation. In 9/16 cases (56%), the preoperative histological diagnosis based on the MR images was the same as the pathological diagnosis after the operation. In 8 of the 11 cases (73%) whose images showed clear tumor ...
The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI ...
The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. Margins were well ...
To determine MTRs for normal structures and benign diseases in the breast two-dimensional magnetization transfer imaging was performed in 62 patients and in 3 young female volunteers. With regard to the MTRs of measurements in the normal breast tissues, fat tissues which is close to simple cysts in MTRs show little transfer of longitudinal magnetization. MTRs of the muscles was 15.15{+-}6.22%, which exceeded those of breast parenchyma. The breast parenchyma didn`t show the change of MTR value due to the difference of patient age and due to variable amount of fat and fibrous tissues. Breast parenchyma in the two young volunteers clearly showed biphasic change of MTR values in accordance with the menstrual cycle; little transfer value was due to hydration in the postovulatory period and high transfer value was due to dehydration in the preovulatory period. In the remaining one volunteer during lactation period, mammary parenchyma shows sever decrease in MTR, because ...
Nuclear magnetic resonance (NMR) images of live rats with sterile and pyogenic abscesses, hematomas, and various implanted and spontaneous neoplasms demonstrated good contrast differentiation between pathologic and surrounding normal tissues. This differentiation was maximal when both the T1 and T2 tissue relaxation times were used as criteria. Neoplasms have a broad range of T1 and T2 values and may be confused with abscesses or hematomas. Tissue rate constants (1/T1 and 1/T2) are mainly dependent on total water content, the exception being fat, which has a 1/T2 value much shorter than that expected on the basis of water content alone.
Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had ...
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is ...
A newly developed method to support tissue characterization in routine MR imaging is presented. It represents a compromise between the practical requirements of clinical routine (short measurement time, multisection imaging) and the necessary accuracy of the relaxation parameter evaluation. The sequence employed is a modification of the PHAPS technique and works with two excitation pulses. It allows the simultaneous acquisition of all measurement data for the subsequent T1, T2, and rho evaluations. T1 is determined with a specially designed computation formula based on four signal ratios. A multiexponential T2 analysis is performed with use of 28 echoes. From these parameters, relative proton density can be computed.
The purpose of this study is to investigate the role of femoral marrow MR imaging as predictor of outcome for hemopoietic stem cell transplantation (HSCT) in beta-thalassemia major. MR imaging of the proximal femur, including T1- and T2-weighted spin echo and short-tau inversion recovery and in-phase and out-of-phase fast field echo images, was prospectively performed in 27 thalassemia major patients being prepared for HSCT. The area of red marrow and its percentage of the proximal femur were measured, and the presence of marrow hemosiderosis was assessed. Age-adjusted multivariate logistic regression was used to determine the relationship between red marrow area percentage and marrow hemosiderosis and HSCT outcome. Red area percentage were less in patients with successful (90.25{+-}4.14%) compared to unsuccessful transplants (94.54% {+-}2.93%; p=0.01). Red ...
Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature of these lesions is ...
60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A brilliant MR-tomographic imaging of the small bowel is possible under the condition, that ...
To evaluate the yield of SPIR sequences with fat suppression in the diagnosis of optic nerve lesions. T1 and T2weighted fat suppressed SPIR imaging of the optic nerve improves anatomical definition, lesion detection and characterization in optic nerve conditions. [Italian] L'articolo analizza i vantaggi ricavabili dall'utilizzazione delle sequenze SPIR nella documentazione del decorso del nervo ottico e delle sue alterazioni nei pazienti con sospetto clinico e strumentale di malattia retrobulbare. L'utilizzo delle sequenze SPIR consente ottimale visualizzazione del nervo ottico e delle sue eventuali alterazioni senza gli artefatti che limitavano la qualita' delle immagini nelle prime sequenze RM con soppressione del segnale del grasso.
MR studies of 6 patients with intracranial tuberculoma are reviewed. All patients also underwent CT scans which showed hypo- or isodense lesions with abnormal enhancement following contrast administration. MR showed lesions with prolongation of the T1 relaxation time in every case. On the T2-weighted sequences, the signal properties of the tuberculoma varied according to the stage of evolution of the lesion. Incipient tuberculomas appeared as scattered areas of hypointensity surrounded by edema. Mature tuberculomas were composed of a dark necrotic center surrounded by an isointense capsule which was, in turn, surrounded by edema. In one patient, the center of the lesion was hyperintense probably because of liquefaction and pus formation (tuberculous abscess). While both, CT and MR, were equally sensitive in visualizing the intracranial tuberculoma in every patient, MR was slightly superior in demonstrating the extent of the ...
The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI ...
Magnetic resonance (MR) imaging was performed in 26 patients with Ewing's sarcoma of bone preceding and following neoadjuvant chemotherapy, to assess tumour response non-invasively prior to surgery. T1- and T2-weighted spin echo images were obtained. Changes including intra- and extramedullary signal intensities, tumour demarcation, tumour volume and the appearance of residual extramedullary tumour were compared with histophathology of the resected specimens. Reduction of tumour volume was significantly higher in good responders. Other single parameters did not correlated with histologic tumour response. However, when several MR parameters summarized in a classification system were combined, a positive correlation with histopathologic response was found. A limited decrease of tumour volume (<25 %) and/or residual soft tissue mass following chemotherapy correlated with a poor ...
Background: Malformations of cortical development vary in neuronal maturity and level of functioning. Purpose: To characterize regional relative cerebral blood volume (rCBV) and difference in first moment transit time (TTfm) in polymicrogyria and cortical tubers using magnetic resonance (MR) perfusion imaging. Material and Methods: MR imaging and dynamic T2*-weighted MR perfusion imaging were performed in 13 patients with tuberous sclerosis complex, 10 with polymicrogyria, and 18 controls with developmental delay but no macroscopic brain abnormality. Regions of interest were placed in cortical tubers or polymicrogyric cortex and in the contralateral normal-appearing side in patients with malformations. In 'control' subjects, regions of interest were placed in the frontal and parietal lobes in both hemispheres. The rCBV and TTfm of the tuber/contralateral side ...
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis ...
60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A brilliant MR-tomographic imaging of the small bowel is possible under the condition, that ...
Primary malignant lymphoma of the brain is a disease of unknown etiology, which is increasing in incidence and has an unfavorable prognosis. Despite the lack of specific changes on CT or MRI in most cases, these procedures may typically facilitate the diagnosis: A focal-enhancing mass with subependymal spread on CT or MRI and hyperattenuation on nonenhanced CT are the most reliable features in the diagnosis of primary malignant lymphoma of the brain. Peritumoral edema and mass effect are usually not prominent features. On unenhanced CT scans they usually appear homogeneously isodense to mildly hyperdense relative to the gray matter. On MRI these tumors are slightly hypointense on T1-weightedimages and slightly hpyerintense on PD- and T2-weightedimages relative to the gray matter. On CT and MRI enhancement is usually homogeneous. Contrast-enhanced MRI, with its ...
In this review, we demonstrate the developmental appearance, structural features, and reorganization of transient cerebral zones and structures in the human fetal brain using a correlative histological and MRI analysis. The analysis of postmortem aldehyde-fixed specimens (age range: 10 postovulatory weeks to term) revealed that, at 10 postovulatory weeks, the cerebral wall already has a trilaminar appearance and consists of: (1) a ventricular zone of high cell-packing density; (2) an intermediate zone; (3) the cortical plate (in a stage of primary consolidation) with high MRI signal intensity. The anlage of the hippocampus is present as a prominent bulging in the thin limbic telencephalon. The early fetal telencephalon impar also contains the first commissural fibers and fornix bundles in the septal area. The ganglionic eminence is clearly visible as an expanded continuation of the proliferative ventricular zone. The basal ganglia showed an initial aggregation of cells. The most ...
Magnetic resonance (MR) imaging and histopathology were used to diagnose an articular process synovial myxoma in a dog. On MR images, the tumor was characterized by distortion of the left L1-L2 articular process, widening of the articular process joint, and the presence of a mass contiguous with the synovium of the articular process that displaced the spinal cord. The tumor was T2-hyperintense, T1-hypointense, relative to muscle, and had mild contrast enhancement. The MR features of articular process synovial myxoma may be distinct from other diseases of the articular process joint.
In Nuclear Magnetic Resonance (NMR) imaging, contrast is dependent on the emission of radiofrequency waves by atomic nuclei, balanced by several parameters. The high information content of NMR images is due to the multiplicity of its parameters. However, this advantage introduces a difficulty in the interpretation of the contrast. There are three contrast parameters for each tissue: hydrogen nuclei density; relaxation time T1; relaxation time T2. Contrast may be enhanced towards any of these parameters by increasing the emission of radiowaves by atomic nuclei using particular pulse sequences.
Purpose: The purpose of this study was to observe the process of fixation in liver specimens non-invasively by means of magnetic resonance. The fixation process of several formaldehyde-containing solutions was monitored with MRI and MRS at two different temperatures. Materials and Methods: Liver specimens were conserved in aqueous fixative solutions containing formaldehyde concentrations of 0.7, 1.8, 4 and 7.2% and at different temperatures of 5 C and 20 C. MRI was performed with T1-, T2- and PD-weighted TSE sequences, a 2D FLASH-sequence with and without magnetization transfer, and a FISP 3D-sequence on a clinical 1.5 Tesla MR whole-body unit, and MRS with {sup 1}H-spectroscopic methods (STEAM-sequence) on a 3 Tesla MR whole-body unit. Results: The diffusion of formaldehyde into the tissue was best identified on PD- and T1-weightedimages as a band under the liver surface with ...
AbstractPurpose: To implement and examine the feasibility of a three-dimensional (3D) ultrashort TE (UTE) sequence on a 7 Tesla (T) clinical MR scanner in comparison with 3T MRI at high isotropic resolution. Materials and Methods: Using an in-house built saddle coil at both field strengths we have imaged mid-diaphysial sections of five fresh cadaveric specimens of the distal tibia. An additional in vivo scan was performed at 7 Tesla using a quadrature knee coil. Results: Using the same type of saddle coil at both field strengths, a significant increase in SNR at 7T compared with 3T (factor 1.7) was found. Significantly shorter T2* values were found at the higher field strength (T2* = 552.2 126 s at 7T versus T2* = 1163 391 s at 3T). Conclusion: UHF MRI at 7T has great potential for imaging...
This paper proposes an adaptive morphological dilation image coding with context weights prediction. The new dilation method is not to use fixed models, but to decide whether a coefficient needs to be dilated or not according to the coefficient's predicted significance degree. It includes two key dilation technologies: 1) controlling dilation process with context weights to reduce the output of insignificant coefficients, and 2) using variable-length group test coding with context weights to adjust the coding order and cost as few bits as possible to present the events with large probability. Moreover, we also propose a novel context weight strategy to predict coefficient's significance degree more accurately, which serves for two dilation technologies. Experimental results show that our proposed method outperforms the state of the art image coding algorithms ...
... Using a weighted linear regression on randomly selected coincident SSM/I-buoy pairs from each of the climate m codes, it was possible to produce ...
The relationships between severity of iron deficiency anemia, response to iron treatment, respiratory and gastrointestinal illness and weight changes were assessed before (T1) and after (T2) iron therapy. Seventy-five pre-school children from rural Guatemala received daily oral iron (ferrous sulfate 5 mg/kg/day) for eleven weeks, and were classified into one of three groups: (1) severe iron deficient (Hgb < 9.25 g/dl at T1 and > 1g/dl Hgb response (T2-T1) to Fe Rx; (2) moderately iron deficient (Hgb 9.25 g/dl to 11.5 g/dl and T2-T1 > 1g/dl); (3) normal controls (Hgb > 11.5 g/dl and T2-T1 < 1g/dl). When both severely and moderately anemic children were pooled together, there was a statistical significant difference between the number of days ill with gastrointestinal symptoms of these ...
This paper develops a fluid dynamic model using finite difference methods characterizing flow in phantoms simulating in vivo conditions and to compare those results with velocity encoded MR images. The phantom consisted of 1-inch (2.5-cm) tubing with semicircular insert and fluid with viscosity, T1, and T2 comparable to blood. Numeric solutions to Navier-Stokes equations for this system were obtained using finite difference methods, with velocity input function of zero at walls and parabolic at both ends. In resulting color raster (CR) images, color temperature represented velocity value. In velocity-encoded MR images acquired under the same flow conditions, phase is proportional to average velocity during application of flow-encoding gradients. Because these gradients are applied along one direction per acquisition, magnitude and direction of velocity are obtained.
Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging ...
The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weightedimages. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)
Bariatric surgical procedures have become important therapeutic options for treatment of morbid obesity in both adults and adolescents co-morbidities of obesity such as glucose intolerance, type 2 diabetes (T2DM), metabolic syndrome, steatohepatitis, hyperlipidemia and cardiovascular disease. These co-morbidities of obesity have significant impacts on the overall quality of life of the individual and our society at large. Roux-en-Y gastric bypass (RYGB) and the relatively newer procedures of gastric banding (GB) and vertical sleeve gastrectomy (VSG) have proven to be efficacious in achieving rapid weight loss and reversing the comorbidities of obesity. Unfortunately, bariatric procedures are not without risks including micronutrient deficiency, failure to maintain lost weight, and mortalit...
Bariatric surgical procedures have become important therapeutic options for treatment of morbid obesity in both adults and adolescents co-morbidities of obesity such as glucose intolerance, type 2 diabetes (T2DM), metabolic syndrome, steatohepatitis, hyperlipidemia and cardiovascular disease. These co-morbidities of obesity have significant impacts on the overall quality of life of the individual and our society at large. Roux-en-Y gastric bypass (RYGB) and the relatively newer procedures of gastric banding (GB) and vertical sleeve gastrectomy (VSG) have proven to be efficacious in achieving rapid weight loss and reversing the comorbidities of obesity. Unfortunately, bariatric procedures are not without risks including micronutrient deficiency, failure to maintain lost weight, and mortality. Further, the resolution of T2DM has long been understood to precede ...
Tumours lesions of the temporal bone and of the cerebello-pontine angle are rare.This tumours can be separated into benign and malignant lesions. In this paper the CT and MRI characteristica of tumours of the temporal bone and the cerebello-pontane angle will be demonstrated. High resolution CT (HRCT) as usually performed in the axial plane are using a high resolution bone window level setting, coronal planes are the reconstructed from the axial data set or will be obtained directly. With the MRI FLAIR sequence in the axial plane the whole brain will be scanned either to depict or exclude a tumour invasion into the brain. After this,T2-weighted fast spin echo sequences or fatsuppressed inversion recovery sequences in high resolution technique in the axial plane will be obtained from the temporal bone and axial T1-weighted spinecho sequences before and after the intravenous application of contrast ...
Single-shot spin-echo diffusion-weighted echo-planar imaging using a phased-array multicoil was performed to distinguish between normal and cirrhotic livers. Sets of 6 images with different b-value were acquired with breath-holding. Significant differences were observed between controls and cirrhosis cases in the signal ratios when the b-value was 383 s/mm{sup 2}, and apparent diffusion coefficients. (orig.)
Purpose: Cardiomyopathy is one of the major complications of {beta} thalassaemia major as a result of transfusion iron overload. The aim of our study is to evaluate with MR if there is any difference of iron deposition signal intensity (SI) or distribution between non-cardiopatic and cardiopatic thalassaemic patients in order to establish if there is a relationship between cardiopathy and iron deposition. Materials and methods: We studied 20 patients affected by {beta} thalassaemia major, of whom 10 cardiopatic and 10 non-cardiopatic, and 10 healthy volunteers as control group. Serum ferritin and left ventricular ejection fraction were calculated in thalassaemic patients. All patients were examinated using a 1.5 MR unit with ECG-gated GE cine-MR T2*-weighted, SE T1-weighted and GE T2*-weighted sequences. In all cases, using an adequate ROI, ...
The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was ...
The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data ...
Aim: The study aimed to analyze blood pressure (BP) responses in individuals with type 2 diabetes (T2D) over a 24h period following resistance (RES) and aerobic (AER) exercise. Methods: Ten adults with T2D (age: 55.8+/-7.7 years; weight: 79.4+/-14.0kg; fasting glucose: 133.0+/-36.7mg.dL^-^1) underwent: (1) AER: 20min of cycling at 90% lactate threshold (90% LT); (2) RES: three laps of a circuit of six exercises with eight repetitions at 70% 1-RM and 40s of recovery; and (3) a control session of no exercise. Heart rate (HR), and systolic (SBP), diastolic (DBP), mean arterial (MAP) and pulse (PP) BP, as well as lactataemia (Lac), VO2, respiratory exchange ratio (RER) and rate of perceived exertion (RPE) were measured at rest, during exercise and control (CON) periods, and 60min after interve...
Colorectal cancer is extremely rare in children. We report a case of a 12-year-old boy who presented with a five-month history of weight loss and anorexia, associated with vomiting episodes, dizziness,...Full Text Available
Superparamagnetic MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r2/r1, for MnFe2O4, Fe3O4 and CoFe2O4 were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T2 contrast agents for MRI.
Objective. The aim of this study was to assess the capability of high-resolution images obtained with a commercially available pelvic phased-array surface coil to demonstrate normal hip anatomy. Design. We retrospectively analyzed the oblique coronal magnetic resonance (MR) images of hips of 36 consecutive patients acquired on a 1.5-T clinical imager using a pelvic phased-array coil as a receiver, a 16-20 cm field of view, and 5 mm slice thickness. Patients. Thirty-six patients were studied, age 15-81 years. There were 20 males and 16 females. Results and conclusions. The articular cartilage, cortex, superior labrum, and iliofemoral ligament were well visualized on proton density weighted fat saturation (PDF) images. The femoral and obturator vessels, obturator nerve, and various muscles were easily seen on T1-weightedimages. ...
To compare the accuracy of MR imaging using an endorectal-pelvic and a pelvic phased-array coil for preoperative local staging of rectal carcinoma. To determine preoperative staging, 38 patients with rectal carcinoma underwent MR imaging. All patients were examined with both an endorectal-pelvic and a pelvic phased-array coil. All underwent surgery and staging was pathologically confirmed. Two radiologists blinded to pathologic stage analyzed perirectal invasion and perirectal node metastasis, and scored according to a four-point scale. Radiologic and pathologic findings were correlated. Receiver operating characteristic (ROC) analysis of Wilcoxon statistic (W values) was used to compare diagnostic accuracy between the two different MR methods. Interobserver variation was measured using {kappa} statistics. For perirectal invasion, T1WI endorectal-pelvic phased-array coil images (reader 1:0. 854, reader 2:0.818) showed ...
We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded ...
A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer ...
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are ...
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are ...
Nasal cavity volume was studied in 69 healthy volunteers (from 8 to 23 years old) by MRI. The right and left nasal cavity areas were measured on horizontal images displayed directly on the MRI console. The nasal cavity volume was obtained by integrated volume calculation. The nasal cavity volume was positively correlated with age, body height and weight up to age 16. The body height and weight reached a plateau at 16 years, but the nasal cavity volume continued to increase. There was no significant difference in the volumes of the right and left cavities. (author).
Nasal cavity volume was studied in 69 healthy volunteers (from 8 to 23 years old) by MRI. The right and left nasal cavity areas were measured on horizontal images displayed directly on the MRI console. The nasal cavity volume was obtained by integrated volume calculation. The nasal cavity volume was positively correlated with age, body height and weight up to age 16. The body height and weight reached a plateau at 16 years, but the nasal cavity volume continued to increase. There was no significant difference in the volumes of the right and left cavities. (author).
We studied 129 AIDS patients with suspected or proved intracranial manifestations of the disease. The purpose of this study was to compare the diagnostic sensitivity of unenhanced and contrast enhanced CT and unenhanced T{sub 2}-weighted MR. Thus, in 20% of our patients MR but not CT was diagnostic. In another 20% MR provided additional diagnostic information. In conclusion, MR is recommended as the imaging modality of choice in AIDS patients with non-conclusive cranial CT. (orig./GDG).
Ten patients with traumatic femoral neck fracture were studied with MR imaging (0.5 T, Magnetom, Siemens): unenhanced (multiecho, TR/TE = 1,600/30--240 [repetition time/echo time, msec]; gradient echo, TR/TE = 315/14, #theta# = 90 degrees) and Gd-DTPA enhanced (0.1 mM/kg body weight, Magnevist, Schering; gradient echo, TR/TE = 315/14, #theta# = 90 degrees). MR images were compared with clinical-radiographic findings. Digital subtraction angiography of the femoral head (FH) in five patients showed complete interruption of blood supply to the FH in three patients (signal intensity of FH did not increase on postcontrast images) and intact FH arteries in two patients (FH signal increased on postcontrast images, as did the healthy-side signal).
We assessed the age-related changes in magnetization transfer ratio (MTR) value and the ratio of water content in rat brain (frontal lobe and pons) during normal development. All studies were done on 42 normal Wistar rats. MTR was calculated by using the equation (M_o_f_f-M_o_n)/M_o_f_f, where M_o_f_f and M_o_n were the measured signal intensities on the conventional and MT-prepared SPGR images, respectively. The ratios of water content were measured by comparing the wet weight with the dry weight of the frontal lobe and the pons, which were extracted from a rat brain soon after MTR measurements. The ratio of water content was calculated by using the equation 100 x (wet weight-dry weight)/wet weight (%). The ratio of water content decreased markedly during the first 30 days, but the decrease was very slight there after both in the frontal lobe and the pons. The ...
We evaluate the sphere level S-matrix element of two tachyons and two massless NS states, the S-matrix element of four tachyons, and the S-matrix element of two tachyons and two Ramond-Ramond vertex operators, in type 0 theory. We then find an expansion for theses amplitudes that their leading order terms correspond to a covariant tachyon action. To the order considered, there are no T4, T2(-bar T)2, T2H2, nor T2R tachyon couplings, whereas, the tachyon couplings FF-bar T and T2F2 are non-zero.
Abstract Neurodegenerative and neurometabolic disorders may cause significant morbidity and mortality in children. Imaging is important in early diagnosis of metabolic disorders and in determining the extent of brain injury. Especially after the development of new techniques such as diffusion-weighted magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), neuroimaging plays more important role in the diagnosis and management of these disorders. In these disorders, usually a mutation causes a clinically significant block in one or more metabolic pathways. This blockage usually results in either a deficiency of the product or in an accumulation of substrate with damage induced by either storage or toxicity. The presenting symptoms are usually nonspecific. In some of the ...
The role of MRT in the prebiopsy diagnosis of muscular and vascular inflammatory conditions was evaluated prospectively and an optimal method of examination was investigated. 92 patients with a suspected diagnosis of myositis (60 cases) or vasculitis (32 cases) were examined, in each case two extremities were studied using transverse T_1 and T_2weighted SE sequences and double echo STIR sequences on a 0.5 Tesla (56 patients) or 1.5 Tesla magnet (36 patients; T5/S15 Gyroscan, Philips). The site of the biopsy depended on the MRT findings. In 41 patients the suspected diagnosis was confirmed histologically, in two patients an infective myositis was diagnosed on clinical grounds despite negative histology. MRT demonstrated muscle oedema in 86% of patients. There were negative findings after immuno-suppressive therapy (two patients), in focal myositis (3 out of 4 patients) and in one of 7 patients with untreated vasculitis. ...
Fetal MRI can be performed in the second and third trimesters. During this time, the fetal brain undergoes profound structural changes. Interpretation of appropriate development might require comparison with normal age-based models. Consultation of a hard-copy atlas is limited by the inability to compare multiple ages simultaneously. To provide images of normal fetal brains from weeks 18 through 37 in a digital format that can be reviewed interactively. This will facilitate recognition of abnormal brain development. T2-W images for the atlas were obtained from fetal MR studies of normal brains scanned for other indications from 2005 to 2007. Images were oriented in standard axial, coronal and sagittal projections, with laterality established by situs. Gestational age was determined by last menstrual period, earliest US measurements and sonogram performed on the same day as the MR. ...
In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional ...
The high incidence and mortality rates of prostate cancer have stimulated research for prevention, early diagnosis and appropriate treatment. DNA ploidy status of tumour cells is an important parameter with diagnostic and prognostic significance. In the current study, DNA ploidy analysis was performed using image cytometry technique and digital image processing and analysis. Tissue samples from prostate patients were stained using the Feulgen method. Images were acquired using a digital imaging microscopy system consisting of an Olympus BX-50 microscope equipped with a color CCD camera. Segmentation of such images is not a trivial problem because of the uneven background, intensity variations within the nuclei and cell clustering. In this study specific algorithms were developed in Matlab based on the most prominent image segmentation approaches that emanate ...
To assess whether ring enhancements of liver metastases on Mn-DPDP enhanced, early MR images were well visualized on delayed images, as compared with those of hepatocellular carcinomas (HCC), and to investigate the detection accuracy and conspicuity of each tumor. Twenty patients with liver metastases and 15 with HCC were studied by Mn-DPDP enhanced, T1-weighted MR images. Peripheral ring enhancement and conspicuity were investigated. Differences in detection accuracy and frequency of ring enhancement in liver metastases and HCC were assessed. In liver metastases (n= 69), 44 cases (63.8%) without ring enhancement and 25 (36.2%) with were noted on early images. Sixteen cases (23.2%) without ring enhancement, 38 (55.1%) with ring enhancement similar to the early images, and 15 (21.7%) with prominent ring enhancement were noted on delayed ...
Analysis of damages done by the radiation in a polymer characterized by optic properties of polished surfaces, of uniformity and chemical resistance that the acrylic; resistant until the 150 centigrade grades of temperature, and with an approximate weight of half of the glass. An objective of this work is the development of a method that analyze in automated form the superficial damages induced by radiation in plastic materials means an images analyst. (Author)
Abstract Here we propose a software for the estimation of the occupied area and volume of fungal cultures. This software was developed using a Matlab platform and allows analysis of high-definition images from optical, electronic or atomic force microscopes. In a first step, a single hypha grown on potato dextrose agar was monitored using optical microscopy to estimate the change in occupied area and volume. Weight measurements were carried out to compare them with the estimated volume, revealing a slight difference of less than 1.5%. Similarly, samples from two different solid-state fermentation cultures were analyzed using images from a scanning electron microscope (SEM) and an environmental SEM (ESEM). Occupied area and volume were calculated for both samples, and the results obtained w...
The objective of this study was to develop full body CAD geometry of a seated 50th percentile male. Model development was based on medical image data acquired for this study, in conjunction with extensive data from the open literature. An individual (height, 174.9?cm, weight, 78.6???0.77?kg, and age 26?years) was enrolled in the study for a period of 4?months. 72 scans across three imaging modalities (CT, MRI, and upright MRI) were collected. The whole-body dataset contains 15,622 images. Over 300 individual components representing human anatomy were generated through segmentation. While the enrolled individual served as a template, segmented data were verified against, or augmented with, data from over 75 literature sources on the average morphology of the human body. Non-Uniform Rational...
One of the main goals in the determination of three-dimensional macromolecular structures from electron microscope images of individual molecules and complexes (single particles) is a sufficiently high spatial resolution, about 4 A, at which the interpretation with an atomic model becomes possible. To reach high resolution, an iterative refinement procedure using an expectation maximization algorithm is often used that leads to a more accurate alignment of the positional and orientational parameters for each particle. We show here the results of refinement algorithms that use a phase residual, a linear correlation coefficient, or a weighted correlation coefficient to align individual particles. The algorithms were applied to computer-generated data sets that contained projections from model structures, as well as noise. The algorithms show different degrees of over-fitting, especially at high resolution where the signal is weak. We demonstrate ...
Purpose: To develop an accurate, fast, and robust algorithm for registering portal and computed tomographic (CT) images for radiotherapy using a combination of sparse and dense field data that complement each other. Methods and Materials: Gradient Feature Weighted Minimax (GFW Minimax) method was developed to register multiple portal images to three-dimensional CT images. Its performance was compared with that of three others: Minimax, Mutual Information, and Gilhuijs' method. Phantom and prostate cancer patient images were used. Effects of registration errors on tumor control probability (TCP) and normal tissue complication probability (NTCP) were investigated as a relative measure. Results: Registration of four portals to CTs resulted in 30% lower error when compared with registration with two portals. Computation time increased by nearly 50%. GFW Minimax performed the best, ...
The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weightedimages (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted ...
Background. Metabolic disturbances such as anoxia and hypoglycaemia are important in causing maldevelopment of the neonatal brain. While there have been some pathology studies of the effects of neonatal hypoglycaemia on brain development, reports of MRI findings in such infants have been rare. Objectives. To describe the MRI findings in neurologically handicapped children who had suffered from neonatal hypoglycaemia and to evaluate the relationship between the neurological impairment and neonatal hypoglycaemia. Materials and methods. We retrospectively evaluated the MRI findings in eight full-term infants with neonatal symptomatic hypoglycaemia who later exhibited neurological handicap. The age at which the MRI scans were obtained ranged from 9 months to 8 years 10 months (mean 4 years 1 month, median 4 years). Results. The most striking findings were prolonged T1 weighting and T2weighting in the ...
To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI ...
This study evaluated surface characteristics and overlaying properties of wood plastic composite (WPC) panels made from dry-blended rubber wood fiber-polypropylene (PP) powder formulations using a conventional flat-press process under laboratory conditions. Three levels of rubberwood fibers (Hevea brasiliensis), 40%, 50%, and 60%, based on the composition by weight, were mixed with the PP powder without and with 3% (based on weight) maleic anhydride grafted PP (MAPP) as a coupling agent. Contact angle measurements on the WPC samples were performed using a goniometer connected with a digital camera which collected one image per second. Roughness measurements, average roughness (R a), mean peak-to-valley height (R z), and maximum roughness (R y), were taken from the sanded samples along and ...
T-2 toxin, a highly toxic member of the type-A trichothecenes, is produced by various Fusarium moulds that can potentially affect human health. It is strongly cytotoxic for human hematopoietic progenitors. Alimentary toxic aleukia (ATA), a disease typically associated with human, is primarily induced by T-2 toxin. A comparison of the metabolism of T-2 toxin incubated with hepatocytes of rats, piglets, chickens, and the hepatic subcellular fractions (microsomes and cytosol) of piglets, chickens, rats, and carp (common carp and grass carp) was carried out. The activities of the recombinant pig CYP3A29 on the transformation of T-2 and HT-2 toxins were preliminary studied. Metabolites were identified by novel LC/MS-IT-TOF. Qualitative similarities and differences across the species were observ...
BackgroundIn recent years, near-infrared fluorescence (NIRF)-labeled iron nanoparticles have been synthesized and applied in a number of applications, including the labeling of human cells for monitoring the engraftment process, imaging tumors, sensoring the in vivo molecular environment surrounding nanoparticles and tracing their in vivo biodistribution. These studies demonstrate that NIRF-labeled iron nanoparticles provide an efficient probe for cell labeling. Furthermore, the in vivo imaging studies show excellent performance of the NIR fluorophores. However, there is a limited selection of NIRF-labeled iron nanoparticles with an optimal wavelength for imaging around 800 nm, where tissue autofluorescence is minimal. Therefore, it is necessary to develop additional alternative NIRF-labeled iron nanoparticles for application in this area.ResultsThis study manufactured 12-nm DMSA-coated Fe3O4 nanoparticles labeled with a ...
Brain development during the first year of life was assessed quantitatively using apparent diffusion coefficient (ADC) images constructed from diffusion-weighted MR image data. The imaging plane was coronal at the section of the pons. The cerebral peduncle, internal capsule, corona radiata, superior longitudinal fasciculus and thalamus were selected for evaluation of their ADC values. A diffusion sensitive gradient was added in the anteroposterior direction. Thus the orientation of nerve fibers in the cerebral peduncle, internal capsule and corona radiata was perpendicular to it, and that in the superior longitudinal fasciculus was parallel to it. In neonates, the cerebral peduncle and internal capsule, having been moderately myelinated at birth, showed the slowest diffusion. The corona radiata and superior longitudinal fasciculus, having been unmyelinated at birth, showed the fastest diffusion. The ...
The authors investigated the effect of T-2 toxin on rat liver mitochondrial protein synthesis. Isolated rat liver mitochondria were supplemented with an S-100 supernatant from rat liver and an external ATP-generating system. An in-vitro assay employing cycloheximide, and inhibitor of cytoplasmic protein synthesis, and chloramphenicol, and inhibitor of mitochondrial protein synthesis, to distinguish mitochondrial protein synthesis from the cytoplasmic process. Amino acid incorporation into mitochondria was dependent on the concentration of mitochondria and was inhibited by chloramphenicol. The rate of uptake of tritium leucine into mitochondrial protein was unaffected by the addition of T-2 toxin and was not a rate-limiting step in incorporation. However, 0.02 micrograms/ml of T-2 toxin decreased the rate of protein synthesis inhibition correlated with the amount ...
This study was performed to evaluate the diagnostic usefulness of double-phase Tc-99m MIBI parathyroid scintigraphy with single photon emission computed tomography (SPECT) in patients with hyperparathyroidism. We also evaluated the relationship between Tc-99m MIBI uptake and oxyphil cell contents in parathyroid glands. The subjects were 28 parathyroid glands of 10 patients who underwent Tc-99m MIBI parathyroid scintigraphy and parathyroidectomy for clinically suspected hyperparathyroidism. Early and delayed pinhole images were obtained at 15 minutes and 2 hours after injection of Tc-99m MIBI, and SPECT images were followed. The weight and oxyphil cell contents of parathyroid tissue were obtained from pathologic specimen, and the scintigraphic findings were compared with histopathology. In surgical histopathology, 6 parathyroid adenomas and 9 parathyroid hyperplasias were confirmed. The sensitivity, specificity, and positive ...
In this work, a pre-cracked semi-circular shaped explosive simulant was loaded using a split Hopkinson pressure bar (SHPB). A high-speed camera was used to capture the deformation and fracture process of the specimen in situ. The digital images were processed using the digital image correlation (DIC) method. Next, full displacement and strain fields were obtained. The displacement vector field shows that the specimen fractured under tensile stress action. The strain field can be used to predict the crack propagation. Results show that the method of combined DIC and SHPB is effective to study the dynamic deformation and fracture behavior of explosive simulants. In addition, the specimen was loaded using a drop weight. The fracture toughness of the specimen was preliminary measured.
The authors propose a method for determining the risk of femoral neck fracture in osteoporotic patients that is not based on densitometric techniques. The method is based on a structural analysis performed by a computer on data taken from a single digital anteroposterior projection of the hip. From the image, the effective cross-sectional area and cross-sectional moment of inertia are computed from attenuation principles. Together with other geometric measurements, these data are used in an engineering analysis to compute the yield strength of the proximal femur, under stress applied through the acetabulum in a one-legged stance. An index of fracture risk based on the ratio of estimated yield strength to body weight is proposed. Ultimately it is expected that this work will allow the clinician to estimate hip fracture risk in osteoporotic patient using widely available existing technology, a goal which has eluded bone density-based methods.
Authors obtained T1-weighted MRI images of the femoral head after fracture of the femoral neck and classified the signals into four patterns to investigate the sequential changes of the femoral head. The T1-weighted MRI images obtained initially after femoral neck fracture showed a normal pattern in 10 of the 15 hip joints studied. MRI images obtained subsequently still showed the normal signal pattern in eight of the 10 hip joints which had shown the normal pattern in the first MRI, while two of the 10 joints subsequently showed a band pattern. The joint with the homogeneous pattern in the first MRI subsequently showed a band pattern. Of the three joints with an inhomogeneous pattern in the first MRI, two joints showed a subsequent band pattern, and the other a normal pattern. The joints which showed a band pattern continued to show a similar band pattern. Eventually, all hip ...
Magnetic resonance (MR) images of 18 cases of hilar cholangiocarcinoma were evaluated to compare the effectiveness of Gd-DTPA with that of high dose contrast enhancement computed tomography (HCE-CT) in detecting the primary tumor. The primary tumor was demonstrated as having slightly low intensity compared with liver parenchyma and high intensity compared with the delated bile duct on T1-weightedimages. In contrast, MRI using Gd-DTPA, which was carried out in five cases, revealed intense enhancement of the tumor. As the differentiation between cholangiocarcinoma and dilated bile duct was difficult, it was concluded that the use of Gd-DTPA improves the efficacy of MRI in diagnosing cholangiocarcinoma. Gd-DTPA was also effective in differentiating the growth pattern of the tumor: the infiltrating type was demonstrated as thickening of the wall of the bile duct, the polypoid type as a soft tissue mass in the bile duct. ...
In the case of injuries of the ankle joint, an imaging technique is expected to reveal the state of the bones, ligaments, and articular cartilage. Irrespective of novel imaging techniques, a plain radiography will be made in order to obtain a first picture of the injury. Examples are given, showing that further orientation along the Lauge-Hansen classification scheme of this type of injury helps to completely ascertain the damage to the Articulatio talocruralis. Further examinations applying specific methods such as arthrography will detect possible, isolated syndesmosis ruptures; lesions of the ligaments can also be directly detected by CT or MRT. The articular cartilage and its lesions can be visualized by a combination of CT and arthrography, but are better shown by the completely non-invasive MRT. This latter method also gives insight into pathological processes with the bone. It allows to detect necrotic bone regions and their ...
Three dimensional data of brain from the formalin-fixed fetuses were collected without isolation, by the 4.7 tesla super high magnetic field MRI and the developmental process of the cerebral parenchyma was studied by 3D images. Subjects were 13 fetal brain and MRI was performed using 3D-steady-state free precession sequence. The isolated brain is very soft and fragile and is deformed by its weight at the imaging. However 3D-MRI can be obtained without isolation, and the deformation is remarkably small. The subependymal germinal matrix layer did not be observed in 7 weeks-old fetus, appeared at 9 weeks-old and increased gradually. Then it rapidly reduced from 28 weeks-old. The volume calculated, from 3D-MRI, increased rapidly from 9 weeks-old to 23 weeks-old, and reached the maximum (2.346 mm"3) at 23 weeks-old. The relation between fetal ages and volume of cerebral ventricle also showed similar pattern. This method will be ...
The clinical results of electron beam therapy using intraoral cone in 8 cases of primary and recurrence carcinoma of tongue (T1 and smaller T2) were reported. The primary and recurrence cases were 5 and 3, respectively. In the 5 cases, a total dose of 10-30 Gy external radiation therapy were combined prior to electron beam therapy. The total dose of electron beam therapy varied from 40 to 60 Gy. In all cases, tumor showed good response and disappeared clinically. Radiation stomatitis, pain of the tongue with masticatory disturbance due to tenderness were complicated in all cases. These complications gradually disappeared 2 to 6 months after treatment. However, loss of body weight and bone exposure were not recognized in any case. Intraoral-cone electron beam therapy is thought to be available and has less complications comparing interstitial irradiation therapy from the review of literature. Within 6 months after radiation, ...
A 3-D hydrodynamic dispersion model for tracer transport is developed and implemented into the TOUGH2 EOS3 (T2R3D) module. The model formulation incorporates a full dispersion tensor, based on a 3-D velocity field with a 3-D, irregular grid in a heterogeneous geological system. Two different weighting schemes are proposed for spatial average of 3-D velocity fields and concentration gradients to evaluate the mass flux by dispersion and diffusion of a tracer or a radionuclide. This new module of the TOUGH2 code is designed to simulate processes of tracer/radionuclide transport using an irregular, 3-D integral finite difference grid in non-isothermal, three-dimensional, multiphase, porous/fractured subsurface systems. The numerical method for this transport module is based on the integral finite difference scheme, as in the TOUGH2 code. The major assumptions of the tracer transport module are: (a) a tracer or a radionuclide is ...
The 2- and 8-azido trimer 5'-triphosphate photoprobes of 2-5A have been enzymatically synthesized from [#gamma#-"3"2P]2-azidoATP and [#alpha#-"3"2P]8-azidoAPT by 2-5A synthetase from rabbit reticulocyte lysates. Identification and structural determination of the 2- and 8-azido adenylate trimer 5'-triphosphates were accomplished by enzymatic hydrolyses with T2 RNase, snake venom phosphodiesterase, and bacterial alkaline phosphatase. Hydrolysis products were identified by HPLC and PEI-cellulose TLC analyses. The 8-azido photoprobe of 2-5A displaces p_3A_4["3"2P]pCp from RNase L with affinity equivalent to p_3A_3. The 8-azido photoprobe also activates RNase L to hydrolyze poly(U)["3"2P]pCp 50% at 7 /times/ 10/sup /minus/9/ M in core-cellulose assays. The 2- and 8-azido photoprobes and authentic p_3A_3 activate RNase L to cleave 28S and 18S rRNA to specific cleavage products at 10/sup /minus/9/ M in rRNA cleavage assays. The nucleotide binding ...
The objectives of this paper are to: quickly outline the extent of the care gap in osteoporosis; define T-2 (knowledge) translation and its relationship to quality improvement; discuss the barriers to best practice in osteoporosis care after a fracture; convey the importance of rigor in design and evaluation of translational interventions by drawing upon examples from the broader literature; describe in some detail a series of post-fracture intervention trials conducted in Alberta, Canada; and make some conclusions specifically about osteoporosis interventions and more generally about T-2 translational research.
Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV ...
Purpose: Liposarcoma is the most common soft tissue sarcoma in adults. The purpose of the study was to correlate MR imaging features with the four ICD subclasses. Methods: 28 patients with liposarcoma were examined preoperatively on a 1.0 T MRI system, using spin echo sequences, gradient echo imaging and STIR sequences. In all patients, classification of the liposarcomas was made by histologic diagnosis (ICD-10-M-classification). Results: Well differentiated liposarcomas (9 patients) showed a number of MRI features consistent with lipoma (well defined mass high signal intensity (SI) on T{sub 1} images, low signal on T{sub 2} images, no or only little signal increase of tumour tissue after contrast material application, no necrosis). Not well differentiated liposarcomas (myxoid 14 patients, pleomorphic three patients, round cell two patients) revealed the largest part of the mass to be of low SI on T{sub ...
Colorectal carcinoma is a highly prevalent and common cause of cancer in Taiwan. There is still no available cure for this malignant disease. To address this issue, we applied the multimodality of molecular imaging to explore the efficacy of diagnostic and therapeutic nanoradiopharmaceuticals in an animal model of human colorectal adenocarcinoma [colorectal cancer (CRC)] that stably expresses luciferase (luc) as a reporter. In this study, an in vivo therapeutic efficacy evaluation of dual-nanoliposome (100 nm in diameter) encaged vinorelbine (VNB) and "1"1"1In-oxine on HT-29/luc mouse xenografts was carried out. HT-29/luc tumor cells were transplanted subcutaneously into male SCID mice. Multimodality of molecular imaging approaches including bioluminescence imaging (BLI), gamma scintigraphy, whole-body autoradiography (WBAR) and in vivo tumor growth tracing, histopathology and biochemistry/hematology analyses were applied ...
The presence of two major aminopeptidases (aminopeptidases I and II) in the giant alga Chara australis was shown using polyacrylamide gel electrophoresis. Partially purified aminopeptidase I had a molecular weight of about 120,000, hydrolyzed both leucine-?-naphthylamide (pH optimum 6.0) and alanine-?-naphthylamide (pH optimum 7.5), and was located both inside and outside the vacuole. Aminopeptidase I was inhibited by p-chloromercuribenzoic acid, iodoacetic acid, 1,10-phenanthroline, and N-tosyl-l-phenylalanine chloromethyl ketone. Aminopeptidase II hydrolyzed alanine-?-naphthylamide but not leucine-?-naphthylamide and was located only outside the vacuole.ImagesFig. 1Fig. 2Fig. 4Fig. 5
We studied age-related microstructural changes in the subcortical white matter from adolescence to middle age in 16 healthy male subjects (age range: 12 to 47 years) using diffusion-weighted magnetic resonance (MR) imaging (DWI). Mean diffusivity (MD) of subcortical white matter was mapped onto the overlying cortical surface using our original method. The mean MD values within 76 cortical regions were measured using atlas-based gray matter segmentation and then correlated with age. A significant negative correlation with age was observed in subcortical MD values in several cortical regions, primarily over the bilateral temporal and occipital lobes. Our results demonstrated subcortical microstructural change in postadolescence that may reflect continuing myelination. (author)
Objective To demonstrate clinical features of a patient subgroup presenting with polycystic ovary syndrome (PCOS) without polycystic ovary morphology. Design Retrospective study. Setting Hospital-based IVF center. Patient(s) In the present study, 876 PCOS patients were selected from women who visited the Reproductive Medicine Center at Shandong Provincial Hospital, Shandong University, between September 2004 and October 2006. Women with PCOS were divided into two groups based on ultrasound image: group A, PCOS patients with classic polycystic ovary (n = 800); group B, PCOS patients without polycystic ovary morphology (n = 76). The following available data were analyzed in the large cohort of women: body height, weight, waistline, hip circumference, hirsutism scores, family history, serum s...
A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source and the X-ray sensing means on opposite sides relative to the table member and ...
This article considers a hypothetical imaging device with a spinning slat collimator that measures parallel-planar-integral data from an object. This device rotates around the object 180 deg. and stops at N positions uniformly distributed over this 180 deg. . At each stop, the device spins on its own axis 180 deg. and acquires measurements at M positions uniformly distributed over this 180 deg. . For a fixed total imaging time, an optimal distribution of the scanning time among the data measurement locations is searched by a nonlinear programming method: Nelder-Mead's simplex method. The optimal dwell time is approximately proportional to the weighting factor in the backprojector of the reconstruction algorithm. By using an optimal dwell-time profile, the reconstruction signal-to-noise ratio has a gain of 23%-24% for the filtered backprojection algorithm and a gain of 10%-18% for the iterative algorithms, compared with the ...
In the search for new brain imaging agents for use with single photon emission computed tomography (SPECT), quantitative structure activity relationship (QSAR) analysis of the correlations between initial brain uptake and physicochemical parameters like lipophilicity, log P, molecular weight, log MW and log U/D (undissociated/dissociated), of the {sup 99m}Tc-DADT (diaminedithiol) complexes and {sup 99m}Tc-PAO (propyleneaminoxime) complexes have been analyzed. High correlations are found for both the {sup 99m}Tc-DADT complexes (r = 0.94) and for the {sup 99m}Tc-PAO complexes (r = 0.83) which are significant at 99.9 and 99.5 percentile level, respectively. These results will help the further design of better ligands for {sup 99m}Tc in brain imaging. (author).
Brain MRI was carried out in patients with chronic liver diseases. No abnormal findings were recognized in patients with chronic viral hepatitis, while 59.2% of cirrhotics showed a symmetrically strong signal in basal ganglia on T1 weightedimage in MRI. This finding significantly related with lowered Fischer`s ratio of serum amino acid, increased levels of serum phenylalanine, tyrosine and hyaluronic acid, prolonged prothrombin time and decreased platelet counts in the peripheral blood. Overt hepatic encephalopathy was observed in 6 of 34 patients with the strong signal in MRI during follow-up period, while none of patients without that finding developed hepatic encephalopathy. These results have indicated that the strong signal in basal ganglia on MRI appears in cirrhotic patients with severe liver dysfunction, and it is an useful index in the early diagnosis of latent hepatic encephalopathy. An improvement of this MRI finding was not ...
Light Weight Composite Mirrors for Science Instruments. Composite Optics, Inc. San Diego, CA. INNOVATION. Light weight, large aperture reflectors of graphite ...
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)
Introduction: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. Methods: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the signal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. Results: The signal- and contrast-to-noise ratios were significantly (P<0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 ...
Aim: Today, MRI is an integral part of the presurgical evaluation of patients suffering from partial epilepsy. These patients frequently show focal morphological abnormalities with potential epileptogenic character and surgical resection of these lesions is associated with superior postsurgical outcome as to seizure frequency. Apart from easily detectable defects, such as post-traumatic lesions or cerebral infarction, as wide variety of mainly small abnormalities can be detected using MRI. Methods: In this study, 484 patients suffering from partial epilepsy of temporal or frontal onset were evaluated for the incidence of different lesions in this population. Results: All lesions found were included without evaluating their potential epileptogenicity, which remains to be proven using other procedures (EEG, SPECT, PET, etc.). Involvement of the hippocampal formation was a major finding in temporal lobe epilepsy, which could be detected as sclerosis ...
A polyolefin composition is described comprising: 100 parts by weight of polyolefin, not less than 0.5 part by weight of a polyamide selected from the group consisting of nylon 6 and nylon 66, and from 3 to 30 percent by weight of a novolak based on the weight of the polyamide.
Abstract Background: Obstructive sleep apnea (OSA), a highly prevalent condition, is independently associated with increased risks of developing type 2 diabetes mellitus (T2D) and metabolic syndrome. It is unclear, however, if the severity of OSA has any impact on glycemic control among patients with T2D. We therefore aimed to determine the independent association between OSA severity and glycosylated hemoglobin (HbA1c) in patients with T2D. Methods: This was an observational cross-sectional study of 52 consecutive patients attending the diabetes obesity clinic between January 2008 to February 2010 with risk factors for sleep apnea and who underwent polysomnography study. Clinical, demographic, and lifestyle data were recorded using a questionnaire. Results: Prevalence of OSA in this clini...
To obtain the low birth weight (LBW) rate, the very low birth weight (VLBW) rate, and gestational age (GA)-specific birth weight distribution based on a large population in Korea, we collected and analyzed...Full Text Available
Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed ...
Intraindividual variability of measurements of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), nicotine, cotinine, and r-1,t-2,3,c-4-tetrahydroxy-1,2,3,4-tetrahydrophenanthrene...Full Text Available
Angelin Pedra is a specie found in the north of Mato Grosso State in Brazil, where an expressive volume of waste of this wood is produced. An alternative to recycle this waste is to produce wood plastic composites. However, structural and chemical investigations are fundamental to generate information for this use. In the present work, low field NMR was used to determine the spin-lattice and spin-spin relaxation times with objective to investigate the molecular dynamic behavior of the alburnu and cerne regions of Angelin Pedra aiming at a potential use of this waste wood in polymeric composites. The results of the proton spin-lattice relaxation time (T1H) and the proton spin-spin relaxation time (T2H) showed at least three different mobility domains for both regions. Among the values, one was very flexible and other was rigid. Knowing that wood is a polymer composite basically constituted by cellulose, hemicellulose and lignin can attribute the ...
Type 2 diabetes mellitus (T2DM) results from insulin resistance and β-cell dysfunction, in the setting of hyperglucagonemia. Glucagon is a 29 amino acid peptide hormone, which is secreted from...Full Text Available
Insulin resistance in skeletal muscle is a key phenotype associated with type 2 diabetes (T2D) for which the molecular mediators remain unclear. We therefore conducted an expression analysis of human...Full Text Available
Sentinel node biopsy is an alternative to elective neck dissection for the management of T1/T2 oral and oro-pharyngeal squamous cell carcinomas and is also finding application to head and neck cancer...Full Text Available
Experimental techniques are presented that can be used to assay and correct for differential light scattering effects in circular dichroism spectra of biological macrostructures. The assay is based...Full Text Available
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T{sub 2}-weighted turbo-spin-echo (TSE) and T{sub 1}-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm{sup 2}. Lymph nodes with a diameter of {>=}8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes ({>=} 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of ...
Purpose: The aim of this study was to evaluate the accuracy of MRI in the measurement of cartilage thickness of the ankle joint in comparison to pathologic and histologic specimens. Patients and methods: The ankle joints of four fresh cadaver feet were imaged on a 1.5 T MR-unit in the coronal plane. Standard T{sub 1}-weighted spin echo (SE) and a T{sub 1}-weighted 3D-GE (FLASH-3D) sequence with fat saturation were applied. Following MR imaging, the talus was explanted and cut parallel to the MR images for macroscopic evaluation and histologic specimens were prepared. MRI measurements of the cartilage thickness of the talus were carried out in two ways: Without and with consideration of a transition zone of intermediate signal intensity between hyperintense cartilage and hypointense cortical bone. The data were compared with the anatomic specimens as the gold standard expressing the ...
A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam and a research prototype, flat-panel, electronic portal imaging device. Immediately following CT imaging, the planned IMRT beams are delivered using the multiple-static field technique. The delivered fluence is sampled using the same detector as for the CT data. The signal measured by the portal imaging device is converted to primary fluence using an iterative phantom-scatter estimation technique. This primary fluence is back-projected through the previously acquired megavoltage CT model of the phantom, with inverse attenuation ...
... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...
To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI ...
T{sub 2} weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T{sub E}=90 ms, T{sub R}=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, ...
Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T{sub 2}-weighted spin echo (SE) images as well as T{sub 1}-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 meningiomas and 15 of 19 metastases ...
We study the stellar and dust properties of a well-defined sample of local elliptical galaxies to investigate the relationship between host galaxy properties and nuclear activity. We select a complete sample of 45 ellipticals from the Palomar spectroscopic survey of nearby galaxies, which includes 20 low-luminosity active galactic nuclei classified as LINERs and 25 inactive galaxies. Using a stellar population synthesis method, we compare the derived stellar population properties of the LINER versus the inactive subsamples. We also study the dust and stellar surface brightness distributions of the central regions of these galaxies using high-resolution images obtained with the {\\it Hubble Space Telescope}. Relative to the inactive subsample, ellipticals hosting LINERs share similar total optical and near-infrared luminosity, central stellar velocity dispersions, and nuclear stellar populations as judged from their luminosity-weighted ages and ...
In our continued efforts for improving the performance of zinc anodes for a Zn/air battery, we now report the preparation of three alloys and improved performances of anodes made up with these alloys. The alloys contained zinc, nickel, and indium with different weight percentages and were calcined at two different temperatures. Out of the six alloys, the alloy which has a composition of zinc 90%, nickel 7.5% and Indium 2.5% and fired at 500{sup o}C is found to be the best. In the case of the hydrogen evolution reaction, this alloy had its potential shifted to a more negative potential. As far as the cyclic voltammograms were concerned, the difference between the anodic and cathodic part was minimal when compared with other alloys. Surprisingly, this alloy had reversibility even after 100 cycles of the cyclic voltammogram. This is a clear indication that dendrite formation was reduced to a considerable extent. Images taken with a scanning ...
The MRI morphology in combined subacute degeneration has only rarely been reported. We describe two patients suffering from subacute combined degeneration of the spinal cord on the basis of a deficiency of vitamin B{sub 12}. In both patients characteristic hyperintense areas on T{sub 2}-weightedimages in the posterior columns of the cervical and thoracic cord without contrast enhancement were demonstrated by MRI. (orig.) [Deutsch] Bisher liegen zur wenige Beschreibungen der MR-Morphologie bei funikulaerer Myelose vor. Wir beschreiben zwei Patienten mit den klinischen Zeichen einer funikulaeren Myelose auf der Basis eines Vitamin B{sub 12}-Mangels. Bei beiden konnten mit der MRT charakteristische Signalanhebungen im T{sub 2}-gewichteten Bild in den Hinterstraengen des zervikalen und thorakalen Rueckenmarks gezeigt werden. Eine Kontrastmittelaufnahme war nicht nachweisbar. (orig.)
Preschool-age children hold negative attitudes toward overweight peers (i.e., anti-fat attitudes), but little is known about individual differences in these attitudes. The current study investigated actual weight status and perceived body size in relation to preschool-age children's anti-fat attitudes. Sixty-nine 4-6 year-olds (61% girls) were individually interviewed about their body size perceptions using a figure rating scale and anti-fat attitudes using multiple methods (including an adjective rating scale and ratings of acceptability for different body shapes). Results suggested that children's perceived body size, not actual body size, was related to their attitudes about an overweight figure and the number of figures rated as acceptable. Children who perceived themselves as heavier held fewer anti-fat attitudes. Perceived and actual body size ratings were not related to ratings of a thin figure. This study suggests the importance of examining children's body ...
Solar High Altitude Powered Platform (Solar HAPP) aircraft are unmanned remote sensing vehicles designed for cruises lasting up to one year at 20-km altitude, while carrying up to 250 pounds of cameras and electrooptic sensors in an underslung payload pod. It is anticipated that real time IR and UV images of earth features may be more inexpensively and accurately obtained by this means than by the conventional geosynchronous earth resources satellites. Solar HAPPs, with wing spans of over 300 ft and weights of only 2000 lb, require ultralight composite structures with external wire bracing. Solar cells will cover both sides of the vertical wing stabilizers and wing tips, which hinge up in daytime to capture the maximum amount of sunlight. A 15-hp electric propulsion unit drives a low-rpm, large diameter propeller; power will be derived from the solar cells diurnally, and from hydrogen-oxygen fuel cells nocturnally. The fuel gases will be ...
Knowledge of factors affecting variation in birth weight is especially important given the relationship of birth weight to neonatal and adult health. The present study utilises two large contemporary...Full Text Available
ObjectiveMaintaining weight loss is a major challenge in obesity treatment. Individuals often indicate that waning motivation prompts cessation of effective weight...Full Text Available
Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available
Purpose: Patients with mycosis fungoides [cutaneous T-cell lymphoma (CTCL)] may benefit from adjuvant therapy after completing total skin electron beam therapy (TSEBT). We report the results for (T1(T2)) CTCL patients treated with adjuvant oral psoralen plus ultraviolet light (PUVA) with respect to overall survival (OS), disease-free survival (DFS), salvage of recurrence, and toxicity. Methods and Materials: Between 1974 and 1993, TSEBT was administered to a total of 213 patients with CTCL. Records were reviewed retrospectively, and a total of 114 patients were identified as having T1 or T2 disease. Radiotherapy was provided via a 6-MeV linac to a total of 36 Gy, 1 Gy/day, 4 days/week, for 9 weeks. Beginning in 1988, patients were offered adjuvant PUVA within 2 months of completing TSEBT. This was started at 0.5-2 J/m"2, 1-2 treatments/week, with a taper over 3-6 months. Therapy then continued once per ...
A new class of (not necessarily bounded) operators related to (mainly infinite) directed trees is introduced and investigated. Operators in question are to be considered as a generalization of classical weighted shifts, on the one hand, and of weighted adjacency operators, on the other; they are called weighted shifts on directed trees. The basic properties of such operators, including closedness, adjoints, polar decomposition and moduli are studied. Circularity and the Fredholmness of weighted shifts on directed trees are discussed. The relationships between domains of a weighted shift on a directed tree and its adjoint are described. Hyponormality, cohyponormality, subnormality and complete hyperexpansivity of such operators are entirely characterized in terms of their weights. Related questions that arose during the study of the topic are solved as well. ...
Purpose: To evaluate a T{sub 2}-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T{sub 2}-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR{sub eff}/T{sub E}/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was ...
Nuclear magnetic resonance is a powerful technique that can be used in a wide range of applications, such as the structural characterization of high molecular weight molecules, conformational studies on enzymes in solution, enzyme-substrate or DNA-protein interactions, monitoring of cell metabolism in vivo, and for diagnostic purposes, employing spectroscopic and imaging techniques. This course was organized in order to introduce the participants to the fundamentals of NMR spectroscopy, and offer practical advice on performing NMR experiments on cell systems, cell and tissue extracts and animal models. The main implications regarding human experiments were also discussed. Finally the quantification of information and the interpretation of data were considered with regard to the main nuclei observed. [Italiano] La risonanza magnetica nucleare e` una delle tecniche spettroscopiche che meglio risponde all`ampio spettro di condizioni imposto dalla ...
We compare the physics potential of the upcoming neutrino oscillation experiments Daya Bay, Double Chooz, NOvA, RENO, and T2K based on their anticipated nominal luminosities and schedules. After discussing the sensitivity to theta_{13} and the leading atmospheric parameters, we demonstrate that leptonic CP violation will hardly be measurable without upgrades of the T2K and NOvA proton drivers, even if theta_{13} is large. In the presence of the proton drivers, the fast track to hints for CP violation requires communication between the T2K and NOvA collaborations in terms of a mutual synchronization of their neutrino-antineutrino run plans. Even in that case, upgrades will only discover CP violation in a relatively small part of the parameter space at the 3 sigma confidence level, while 90% confidence level hints will most likely be obtained. Therefore, we ...
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...
Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available
performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...
This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)
This paper presents an analysis of the applicability of alternative systems for electric vehicle (EV) heating and air conditioning (HVAC). The paper consists of two parts. The first part is a cooling and heating load calculation for electric vehicles. The second part is an evaluation of several systems that can provide the desired cooling and heating in EVs. These systems are ranked according to their overall weight The overall weight is calculated by adding the system weight and the weight of the battery necessary to provide energy for system operation. The system with the minimum overall weight is considered to be the best, because minimum vehicle weight decreases the energy required for propulsion, and therefore increases the vehicle range. Three systems are considered as the best choices for EV HVAC. These are, vapor compression, ice storage and adsorption ...
We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available
In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available
This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available
Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...
Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...
The intensity of luminescence from the "2E state of Cr(bpy)_3"3"+ (bpy = 2, 2'-bipyridine) is lower in D_2O, although the "2E lifetime is unchanged, indicating that the "4T_2 (precursor to "2E) is sensitive to the isotopic nature of the solvent. A photophysical mechanism is proposed for Cr(NN)_3"3"+ complexes.
The impurity susceptibility chisub(m) of the Kondo system (Lasub(1-x)Cesub(x))B_6, x <= 0.018, has been measured for temperatures 0.03-8 K. The alloys show single impurity behavior for x < 0.006. In a wide temperature range chisub(m)(T) follows a Curie-Weiss law with theta=2.8 K and turns to a T"2 law at very low temperatures. (Auth.).
Objective and designLow grade inflammation is of pathogenic importance in atherosclerosis and in the development of cardiovascular disease (CVD) and type 2 diabetes (T2D). Matrix...Full Text Available
sigma confidence of hitting a 21 km atmospheric entry corridor ...... end-point state and the end time f(X,T). (2-27) where X = Nominal end-point state. T = Nominal ..... which assumes a linear filter is given in Reference. 2 to- ...
BackgroundType 2 Diabetes mellitus (T2DM) affects persons of all ages, while also placing heavy economic burdens on national economies and healthcare systems. The study aims to investigate...Full Text Available
Cutaneous T-cell lymphoma is typically a clonal neoplasm of epidermotropic CD4+ T-lymphocytes that includes the entity mycosis fungoides (MF). After identification of patients with recurrent MF treated...Full Text Available
Background: Diet plays a key role in the development of type 2 diabetes (T2D), but little is known about the contributions of specific nutrients in populations in which dietary patterns...Full Text Available
Type II diabetes mellitus (T2DM) is often accompanied by non-alcoholic steatohepatitis (NASH) and associated with hypercholesterolemia, i.e. increased levels of plasma low-density...Full Text Available
The current investigation attempted to confirm the beneficial actions of a chemically characterized Radix Astragali decoction (AM-W) against type 2 diabetic (T2D) Sprague-Dawley (SD) rats. Using a case/control...Full Text Available
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.
A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T{sub ...
The light curves produced by all-sky monitors, such as the Rossi X-ray Timing Explorer All-Sky Monitor and the Swift Burst Alert Telescope (BAT), generally have non-uniform error bars. In searching for periodic modulation in this type of data using power spectra it can be important to use appropriate weighting of data points to achieve the best sensitivity. It was recently demonstrated that for Swift BAT data a simple weighting scheme can actually sometimes reduce the sensitivity of the power spectrum depending on source brightness. Instead, a modified weighting scheme, based on the Cochran semi-weighted mean, gives improved results independent of source brightness. We investigate the benefits of weighting power spectra in period searches using simulated GLAST LAT observations of {gamma}-ray binaries.
Minimally invasive thermotherapies for focal tissue destruction on the basis of laser-, microwave-, focused ultrasound-, or cryogeninduced changes of tissue temperature represent an alternative to surgical tissue ablation, particularly in the treatment of tumors. The thermotherapy modalities listed necessitate indirect guidance and monitoring, since they often do not lend themselves to immediate visual control. In the brain, in head and neck tumors, in the liver, and in the prostate, MRI reliably and accurately delineates both the positions of interstitial thermotherapy applicators and - in contrast-enhanced, T1-weightedimages - the perfusion defects in tissue necrosis induced by thermotherapy. The transfer of results of in-vitro and in-vivo model studies to assess interstitial temperature and lesion development during thermotherapy to the actual treatment of patients, however, is still in an initial phase. Further development of both rapid ...
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself ...
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end application itself set ...
Purpose: `Exoscopic` and endoscopic identification of colorectal pathologies via MRI. Methods: 5 patients (36-88 years), two normal and three with different colorectal pathologies (diverticular disease, polyps and carcinoma of the colon), were examined by MRI after colonoscopy. Subsequent to filling of the colon with a gadolinium-water mixture under MRI-monitoring, 3D-data sets of the colon were acquired in prone and supine positions over a 28 sec breathold interval. Subsequently multiplanar T{sub 1}-weighted 2D-sequences were acquired before and following i.v. administration of Gd-DTPA (0.1 mmol/kg BW). All imaging was performed in the coronal orientation. The 3D-data were interactively analysed based on various displays: Maximum intensity projection (MIP), surface shadowed display (SSD), multiplanar reconstruction (MPR), virtual colonoscopy (VC). Results: All of the colorectal pathologies could be interactively diagnosed by MPR. On MIP ...
The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...
Experiences with weight stigma negatively impact both psychological outcomes (e.g., body dissatisfaction, depression) and behavioral outcomes (e.g., dieting, exercise). However, not everyone is equally affected by experiences with weight stigma. This study examined whether internalized societal attitudes about weight moderated the impact of weight stigma. Adult participants (n = 111) completed measures of experiences with weight stigma, as well as two indexes of internalized societal attitudes (the moderators): Internalized anti-fat attitudes and internalization of societal standards of attractiveness. Psychological outcomes included self-esteem, body dissatisfaction, drive for thinness, and bulimic symptoms; behavioral outcomes included avoidance of exercise and self-reported exercise behavior. Weight stigma was positively correlated with body dissatisfaction, ...
OBJECTIVE: To evaluate the association between fatty acid (alpha-linolenic acid (ALA), EPA, DHA, palmitic, stearic, oleic, linoleic and arachidonic acids) intake and prospective weight change in the Heidelberg cohort of the European Prospective Investigation into Cancer and Nutrition. DESIGN: Prospective cohort study with mean follow-up time of 6.5 years. In a total of 9182 men and 10867 women aged 35 to 64 years, from body weight measurement at recruitment and calibrated body weight during follow-up, weight change was expressed as mean annual weight change relative to baseline weight (%/year) and categorised into four groups (weight loss, or =2.5 to or =7.5%/5 years). Energy-adjusted dietary fatty acid intake data were estimated from the FFQ completed at baseline. Multivariate linear regression models as well as multinomial logistic ...
For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...
To study the three-dimensional (3D) magnetic field topology and its long-term evolution associated with the X3.4 flare of 2006 December 13, we investigate the coronal relative magnetic helicity in the flaring active region (AR) NOAA 10930 during the time period of December 8-14. The coronal helicity is calculated based on the 3D nonlinear force-free magnetic fields reconstructed by the weighted optimization method of Wiegelmann, and is compared with the amount of helicity injected through the photospheric surface of the AR. The helicity injection is determined from the magnetic helicity flux density proposed by Pariat et al. using Solar and Heliospheric Observatory/Michelson Doppler Imager magnetograms. The major findings of this study are the following. (1) The time profile of the coronal helicity shows a good correlation with that of the helicity accumulation by injection through the surface. (2) The coronal helicity of the AR is estimated to ...
A factor which agglutinated the spores of Ceratocystis fimbriata in the presence of Ca2+ was purified from sweet potato (Ipomea batatas Lam cv. Norin[1]) root. Element composition of the purified factor was as follows; analysis found: C (29.8%), H (3.97%), O (65.34%), N (0.81%): calculated for C43H69O70N1: C (30.02%), H (4.01%), O (65.15%), N (0.81%). The factor was mainly composed of galacturonic acid (53% of dry weight) and contained arabinose, fucose, and unidentified component as minor components. The factor also agglutinated A-, B-, AB-, and O types of human erythrocytes to almost the same degree in the presence of Ca2+. The differential spore-agglutinating activity of the factor depended on the pH of the assay medium; it agglutinated similarly the germinated spores of sweet potato and coffee strains at pH 7.5 and 5.5, whereas it displayed a distinct differential agglutinating activity at pH 6.5. The factor was assayed for spore-agglutinating activity at pH ...
Regional cortical thickness was evaluated using CIVET processing of 3D T1-weightedimages (i) to compare the variation in cortical thickness between 33 participants with fetal alcohol spectrum disorders (FASD) aged 6-30 years (mean age 12.3 years) versus 33 age/sex/hand-matched controls, and (ii) to examine developmental changes in cortical thickness with age from children to young adults in both groups. Significant cortical thinning was found in the participants with FASD in large areas of the bilateral middle frontal lobe, pre- and post- central areas, lateral and inferior temporal and occipital lobes compared to controls. No significant cortical thickness increases were observed for the FASD group. Cortical thinning with age in a linear model was observed in both groups, but the locations were different for each group. FASD participants showed thinning with age in the left middle frontal, bilateral precentral, bilateral precuneus and ...
To assess the CT findings of intrahepatic cholangiocarcinoma associated with hepatolithiasis. The CT features of 26 patients with cholangiocarcinoma and hepatolithiasis were reviewed and compared with those of 23 patients with intrahepatic stones alone, acting as control subjects. CT findings were analyzed for tumor appearance and adjacency to hepatolithiasis. We studied clinical findings, noting the presence or absence of wall thickening or soft tissue attenuation within the bile duct, the luminal diameter of dilated bile duct, and the presence of periductal enhancement, and compared these with the findings for control groups. CT images of the tumor revealed a hepatic low-attenuating mass with peripheral rim enhancement(n = 14,54 %), or periductal thickening, or low-attenuating lesions in segmental dilatation of intrahepataic bile ducts(n = 12, 46 %). Most hepatic tumors were seen in areas adjacent to hepatolithiasis, or in a bile duct. Compared with control ...
BackgroundIn Africa low birth weight (LBW) (<2500 g), is the strongest determinant of infant morbidity and mortality. The aim of this study was to quantify the effect of...Full Text Available
PurposeThis study aimed to evaluate weight and height status and their relationship with psychological problems among elementary schoolchildren.Materials and...Full Text Available
OBJECTIVETo estimate the relationship between the rate of gestational weight gain before the 50-g, 1-hour oral glucose challenge test screening for gestational diabetes...Full Text Available
BackgroundObesity has reached epidemic proportions in the United States. It is implicated in the development of a variety of chronic disease states and is associated with increased...Full Text Available
MWo = average molecular weight of fuel est. 105 g/mole for gasoline est. 165 g/mole for Jet fuel est. 230 g/mole for diesel fuel MWX = molecular weight of selected chemical...
Simple recursion formulas are derived for the multiplicities of the dominant weight vectors appearing in a class of irreducible highest weight representations of the indecomposable affine Kac-Moody algebras. This class is characterized by the appearance of exactly two distinct infinite sequences of dominant weight vectors. The general procedure used for the enumeration of these representations and for the derivation of the corresponding multiplicity formulas is that presented by Capps for the analysis of those irreducible representations containing exactly one such infinite sequence. This procedure includes the classification of representations in terms of congruence and the identification of Weyl orbits by the norm of the dominant weight. Some of the results presented have application to physical theories such as string field theories.
On an airplane, the lift force (the aerodynamic force perpendicular to the flight direction) is used to overcome the weight. On a rocket, thrust is used in opposition ...
This patent describes an aqueous clay containing drilling fluid having present in an amount sufficient to reduce fluid loss of the drilling fluid, a copolymer of (1) from about 80% to about 98% by weight of acrylic acid and (2) from about 2% to about 20% by weight of itaconic acid. The copolymer has a weight average molecular weight of between about 50,000 to about 1,000,000, being in its free acid or partially or completely neutralized salt form and being at least water dispersible.
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
Background: Little is known about the effectiveness of behavioral strategies to prevent long-term weight gain among adolescents and young adults.Objective: The objective...Full Text Available
Ammonium nitrate shale oil explosives are provided which are effective, powerful, inexpensive, and safe. The explosives contain about 2% to 10% by weight shale oil and about 90% to 98% by weight ammonium nitrate. The shale oil can be whole shale oil or heavy shale oil containing from 0.1% to 65% by weight oil shale dust. The ammonium nitrate is preferably in the form of explosive grade ammonium nitrate prills.
We study quasifinite highest weight modules over the supersymmetric extension of the W_1_+_#infinity# algebra on the basis of the analysis by Kac and Radul. We find that the quasifiniteness of the modules is again characterized by polynomials, and obtain the differential equations for highest weights. The spectral flow, free field realization over the (B, C)-system, and the embedding into gl(#infinity#vertical stroke #infinity#) are also presented. (orig.).
In clause it is shown a method optimization of brake of forces in view of a bias road it is established, that in mountain conditions of loss of coupling weight of automobiles than 2-3 times concerning flat conditions therma are more. The degree of use of coupling weight in result use of a regulator of brake forces very much increases also efficiency of brake systems such a kind of automobiles is provided with definition of optimum factor of coupling at which value of loss of coupling weight is provided minimal
Irreducible cyclic codes are an interesting type of codes and have applications in space communications. They have been studied for decades and a lot of progress has been made. The objectives of this paper are to survey and extend earlier results on the weight distributions of irreducible cyclic codes, present a divisibility theorem and develop bounds on the weights in irreducible cyclic codes.
A self-selected sample of 417 urban and 379 rural preschool children attending the under-5s clinics was weighed in Sierra Leone. The individual weights were related to the weight-for-age Harvard 3rd...Full Text Available
Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).
Protected cultures are widespread along the Lebanese narrow coastline, encouraged by mild winter conditions. Although one of the most intensive production systems, water and nutrients managements are mostly empirical, based on the experience of the grower himself or of his workers. So far, water has been available in Lebanon, but it will become scarce within ten years. The conservation of water quality by a rational addition of nutrients is particularly relevant to protected cultures. This is important as greenhouses are developed on imported shallow soils that could be fragile and highly vulnerable to pollution. Sound management includes the amount and the forms of fertilizers as well as the modality of fertigation. An experiment was conducted during two spring seasons in a location along the northern coast in a typical unheated greenhouse. The cucumber response to two frequencies and modalities of fertigation was followed: continuous T2C and ...
The nuclear magnetic susceptibility, #chi#, of "3He is seen to nearly obey a pure Curie Law, #chi# = C/T, over the temperature range 0.5 mK < T < 2 K when contained in the 20#ALPHA#, multiply connected pores of Vycor glass at low external pressure. Raising the external pressure to 5 bar (1 bar 100 kPa) causes the susceptibility to obey the Curie-Weiss law, #chi# = C' /T - #THETA# whose #THETA# = 0.3 mK. The longitudinal relaxation time, T_1, varies monotonically with T between 17 and 90 ms at both pressures. At 5 bar, the transverse relaxation time T_2*, is nearly temperature independent (about 600 #mu#s) above 2 mK. Below 2 mK, T_2* drops precipitously. Preliminary measurements indicate that the magnetism is produced by atoms that can flow through the pores of the Vycor glass. (10 refs., fig.).
Central nervous system (CNS) manifestations in acquired immunodeficiency syndrome (AIDS) patients are an early and common feature. The spectrum of AIDS-related CNS diseases are encephalitis caused by the human immunodeficiency virus(HIV) itself, opportunistic infection, infarct and malignancy. We experienced two cases of CNS involvement in AIDS and they were serologically diagnosed as HIV encephalitis and CNS toxoplasmosis, respectively. In the case of the HIV encephalitis patient, brain MRI showed a non-enhancing lesion with high signal intensity on T2WI and low signal on T1WI and there was no mass effect on the right frontal lobe, periventricular white matter, splenium of the corpus callosum or bilateral basal ganglia. In the other case of CNS toxoplasmosis, MR showed multiple nodular and rim enhanced mass lesions in the right basal ganglia, thalamus and periventricular white matter, which were of low signal intensity on T1WI and of high ...
Enthalpy increment measurements on La_2Te_3O_9(s) and La_2Te_4O_1_1(s) were carried out using a Calvet micro-calorimeter. The enthalpy values were analyzed using the non-linear curve fitting method. The dependence of enthalpy increments with temperature was given as: H"o(T) - H"o(298.15 K) (J mol"-"1) = 360.70T + 0.00409T "2 + 133.568 x 10"5/T - 149 923 (373 #<=# T (K) #<=# 936) for La_2Te_3O_9 and H"o(T) - H"o(298.15 K) (J mol"-"1) = 331.927T + 0.0549T "2 + 29.3623 x 10"5/T - 114 587 (373 #<=# T (K) #<=# 936) for La_2Te_4O_1_1.
The validity is given to the newly proposed two weighting {delta}f scheme (Wang et al., Research Report of National Institute for Fusion Science NIFS-588, 1999) for collisional or neoclassical transport calculations, which can solve the drift kinetic equation taking account of effects of steep plasma gradients, large radial electric field, finite banana width, and the non-standard orbit topology near the axis. The marker density functions in weight equations are successively solved by using the idea of {delta}f method and a hierarchy of equations for weight and marker density functions is obtained. These hierarchy equations are solved by choosing an appropriate source function for each marker density. Thus the validity of the two weighting {delta}f scheme is mathematically proved. (author)
The present invention relates generally to an apparatus and method for separating high molecular weight molecules from low molecular weight molecules. More specifically, the invention relates to the use of microdialysis for removal of the salt (low molecular weight molecules) from a nucleotide sample (high molecular weight molecules) for ESI-MS analysis. The dialysis or separation performance of the present invention is improved by (1) increasing dialysis temperature thereby increasing desalting efficiency and improving spectrum quality; (2) adding piperidine and imidazole to the dialysis buffer solution and reducing charge states and further increasing detection sensitivity for DNA; (3) using low concentrations of dialysis buffer and shifting the DNA negative ions to higher charge states, producing a nearly 10-fold increase in detection sensitivity and a slightly decreased desalting efficiency, or (4) ...
The effects of group structures and weighting functions on neutron penetration through a thick Na-Fe geometry are studied. The recommended broad-group (61-neutron/23-gamma-ray) and few-group (22-neutron/10-gamma-ray) structures are tailored to the sodium and iron resonances, windows, and capture gamma-ray spectra. The best weighting functions are shown to be fine-group fluxes selected from a few key locations in the geometry. These group structures and weighting functions, relative to existing group structures and conventional weighting functions, improve the accuracy of the computed 61-neutron-group Bonner ball responses by up to one hundred percent and of the computed 22-neutron-group results by up to six hundred percent.
Summary Dietary fibres are believed to reduce subjective appetite, energy intake and body weight. However, different types of dietary fibre may affect these outcomes differently. The aim of this review was to systematically investigate the available literature on the relationship between dietary fibre types, appetite, acute and long-term energy intake, and body weight. Fibres were grouped according to chemical structure and physicochemical properties (viscosity, solubility and fermentability). Effect rates were calculated as the proportion of all fibre-control comparisons that reduced appetite (n-=-58 comparisons), acute energy intake (n-=-26), long-term energy intake (n-=-38) or body weight (n-=-66). For appetite, acute energy intake, long-term energy intake and body weight, there were cl...
By using the paired comparison methodology, it was possible to establish evaluative priorities, providing criterion weights which reflected the thoughts and feelings of an advisory committee consisting of experts in the task selection process. For the U.S. Army Infantry School, the weights can be used to stress higher weighted criterion results in the task selection process. By extending the size and diversity of the advisory committee, the use of paired comparison methodology can provide an effective, reliable procedure for (1) constructing evaluative criterion weights for the task selection process and in other areas which have multiple criteria used for evaluative purposes and (2) incorporating into an evaluative design the valuable contributions of various experts and interest groups. (Author/BW)
Proper balance control is a key aspect of acitivities of daily living. The aim of this study was to determine the contribution of body weight to predict balance stability. The balance stability of 59 male subjects with BMI ranging from 17.4 to 63.8kg/m2 was assessed using a force platform. The subjects were tested with and without vision. A stepwise multiple regression analysis was used to determine the independent effect of body weight, age, body height and foot length on balance stability (i.e., mean speed of the center of foot pressure). With vision, the stepwise multiple regression revealed that body weight accounted for 52% of the variance of balance stability. The addition of age contributed a further 3% to explain balance control. Without vision, body weight accounted for 54% of the...
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...
The central nervous system (CNS), generally accepted to regulate energy homeostasis, has been implicated in the metabolic perturbations that either cause or are associated with obesity. Normally, the CNS receives hormonal, metabolic, and neuronal input to assure adequate energy levels and maintain stable energy homeostasis. Recent evidence also supports that the CNS uses these same inputs to regulate glucose homeostasis and this aspect of CNS regulation also becomes impaired in the face of dietary-induced obesity. This review focuses on the literature surrounding hypothalamic regulation of energy and glucose homeostasis and discusses how dysregulation of this system may contribute to obesity and T2DM.
The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available
PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available
This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available
A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.
Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available
Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available
Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available
Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available
This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.
The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available
Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available
Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...
An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
While levels of weight bias vary among individuals, it is not clear why one person possesses stronger anti-fat attitudes than another person. This investigation examined whether individual differences commonly associated with greater anti-fat bias are also associated with a greater preference for thinness among people of varying levels of weight. Young adults (62% women; 84% Caucasian) recruited from psychology classes (N=308) rated four male and female figures with approximate BMIs of 18.5, 25, 30, and 40, on measures of dislike and personality characteristics and completed measures assessing weight controllability, attitudes toward the obese, and perceptual reliance. Greater negative attitudes, weight controllability beliefs, and perceptual reliance were positively associated with greater dislike and negative personality attributes among obese/severely obese figures, but inversely related among low ...
Association rule mining aims to explore large transaction databases for association rules. Classical Association Rule Mining (ARM) model assumes that all items have the same significance without taking their weight into account. It also ignores the difference between the transactions and importance of each and every itemsets. But, the Weighted Association Rule Mining (WARM) does not work on databases with only binary attributes. It makes use of the importance of each itemset and transaction. WARM requires each item to be given weight to reflect their importance to the user. The weights may correspond to special promotions on some products, or the profitability of different items. This research work first focused on a weight assignment based on a directed graph where nodes denote items and links represent association rules. A generalized version of HITS is applied to the graph to ...
Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)
A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.
An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.
This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.
Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...
Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and ...
Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...
1 - Description of program or function: This library for fusion neutronics calculations, to be used in conjunction with the TRANSX code, is the MATXS format version of ZZ-GEFF-2-GENDF from which it has been derived by means of the MATXSR NJOY module. It has a 175 neutron, 42 photon VITAMIN-J group structure with the standard weighting function: Maxwellian (at the temperature to which the material is referenced) + 1/E + fission spectrum + 1/E + fusion peak + 1/E. It includes 93 materials from 1-H-1 to Bi-209 - almost all from EFF-2 basic data; but Ag-107, Ag-109, natural Cd, the 6 Hf isotopes and the 4 W isotopes have been taken from JEF-2.2 - at 3 temperatures and 6 dilution cross section values; 10 thermal groups are provided below 3 eV. Neutron cross sections and diffusion matrices, photon and gas production, kerma and DPA are given. The library includes H in H2O, metallic Be and Graphite for which an accurate treatment with S(alpha, beta) matrices has been ...
Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in predicting vascularity after femoral neck ...
Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy of dynamic MRI in predicting vascularity after femoral neck ...
A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T{sub 1}- and T{sub 2}-weightedimages. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG) [Deutsch] In einer prospektiven Studie an 50 Patienten mit einer Osteochondrosis dissecans (OD) des ...
A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps <10 mm, 13 polyps {>=}10 mm, 24 carcinomas) were determined by region-of-interest (ROI) measurements in 38 patients who underwent contrast-enhanced CTC. In addition, the height (H) of the colonic lesions was measured in CT. CT values were also measured in the aorta (A), superior mesenteric vein (V) and colonic wall. The contrast phase was defined by xA + (1 - x)V using x as a weighting factor for describing the different contrast phases ranging from the pure arterial phase (x=1) over the intermediate phases (x=0.9-0.1) to the pure venous phase (x=0). The CT values of the lesions were correlated with their height (H), the different phases (xA + (1 - x)V) and the ratio [xA + (1 - x)V]/H. The CT ...
We investigate theoretically subwavelength imaging by acoustic metamaterial slabs immersed in the liquid matrix. A near-field subwavelength image formed by evanescent waves is achieved by a designed metamaterial slab with negative mass density and positive modulus. A subwavelength real image is achieved by a designed metamaterial slab with simultaneously negative mass density and modulus. These results are expected to shed some lights on designing novel devices of acoustic metamaterials.
X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging
Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.
The computer vision approach to image analysis is discussed from two aspects. First, this approach is constrasted to the pattern recognition approach. Second, how external knowledge and information and models from other fields of science and engineering can be used for image and scene analysis is discussed. In particular, the connections between computer vision and computer graphics are pointed out.
The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.
Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.
This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.
We studied the dose-response effects of #gamma#-irradiation on the weight gains of the body and the brain in ICR mice exposed to various doses of "6"0Co #gamma#-irradiation ranging from 0 to 1.5 Gy on day 13 of pregnancy (E13). We found that 0.5 Gy #gamma#-irradiation caused a significant reduction in brain weight but not in body weight among 6-week-old mice. Higher doses (1.0, 1.5 Gy) seriously inhibited body and brain development, resulting in significantly low weights at 6 weeks of age. A significantly lower brain weight among fetuses exposed to 1.5 Gy was found as early as 24 hours after exposure, while significant reductions in the body weight of these same fetuses appeared 3 days after exposure. The effects of radiation on brain and body development were similar for both males and females. (author).
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
Constrained least-squares techniques have been used to produce a well known class of image restoration algorithms. These techniques typically involve minimizing a linear operator on a vector representation of an image, subject to a constraint. For cases where an equality constraint is appropriate the method of Lagrange multipliers can be used to produce a restored image. In this work a fractal textural model, fractional Brownian motion, is used to represent images of interest. Using a variance fractal dimension estimator a non-linear operator, that represents the squared difference between the fractal dimension of the restored image and on a priori value is minimized, subject to the constraint that the norm of the residual between the restored image and available measurement equal the norm of the additive noise.
Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitized image version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and effectiveness of our approach for an efficient ...
The brain imaging properties of /sup 99m/Tc glucoheptonate, /sup 99m/Tc pertechnetate, and /sup 99m/Tc DPTA are compared. Results demonstrate that optimum images are obtained at 90, 180, and 180 min., for /sup 99m/Tc GH, /sup 99m/Tc DTPA, and /sup 99m/Tc pertechnetate, respectively. The former two images are not affected by prior bone imaging with /sup 99m/Tc pyrophosphate, while /sup 99m/Tc pertechnetate images are adversely affected. /sup 99m/Tc glucoheptonate appears to be the superior agent for brain imaging, followed by /sup 99m/Tc DTPA and /sup 99m/Tc pertechnetate.
1. Chronic exposure of male Microtus pennsylvanicus to photoperiods with 8, 10 and 12 hr of light per day results in gonadal regression, molt to winter pelage and significant reductions in body weight and food consumption relative to voles kept on photoperiods with 13 and 14 hr of light per day. 2. A precise critical daylength is observed in this species as exposure to photoperiods with 12 or fewer hours of light per day results in complete gonadal involution, seasonal molt and loss of body weight. 3. Pinealectomy abolishes all short-photoperiod induced responses in this species. PMID:2573458
A systematic optimization method of choosing the weighting matrix in linear optimal control system design, under the conditions of prespecified closed-loop dominant eigenvalue locations and feedback gain limit constraints, is presented in this paper. Studies show that with the proposed method one can obtain the desired weighting matrix very quickly and conveniently without the heavy burden of choosing a suitable weighting matrix by trail and error. This method can also easily achieve a reduced-order feedback control system. The linear optimal power system stabilizer designed by using the proposed method produces very good performance.
Full text: Many studies have demonstrated significant declines in 24-hour energy expenditure (TEE) measured by whole body calorimetry with either the process of weight loss or the maintenance of reduced body weight. The aims of this study were to determine the effect of weight loss and two weeks of weight maintenance on TEE using ["1"4C]-bicarbonate-urea, Eleven subjects (6 males, 5 females), mean (#+-#SE) age 50 #+-# 3 years, BMI 34.1 #+-# 2.1 kg/m2 and body fat 38.7 #+-# 3% were studied before and after a decrease in body weight of > 8% over a period of 8 weeks, followed by two weeks of weight maintenance. Weight loss was induced using the combination of Modifast and one small meal a day (#approx#3.34 MJ/day). Body composition (DEXA), resting energy expenditure (REE) and the thermic effect of a 2.7 MJ test meal (TEF) were measured in ...
A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.
Gallium imaging is increasingly being used for the early detection of complications in patients with AIDS. A 26-year-old homosexual man who was HIV antibody positive underwent gallium imaging for investigation of possible Pneumocystis carinii pneumonia. Widespread cutaneous focal uptake was seen, which was subsequently shown to be due to mycobacterium avium-intracellulare (MAI) septicemia. This case demonstrates the importance of whole body imaging rather than imaging target areas only, the utility of gallium imaging in aiding the early detection of clinically unsuspected disease, and shows a new pattern of gallium uptake in disseminated MAI infection.
A representation of tensors and spinors at a point of space-time as spin and conformally weighted functions on the unit sphere is derived. Methods for performing algebraic operations on tensors and spinors in this representation are discussed. (author).
The use of Funtumia latex and nitrobenzene as molecular weight depressants for natural rubber was studied. Portions of a given sample of natural rubber latex were treated with these materials, and this provided a means of ascertaining the amount of Funtumia latex in a blend with natural rubber that could produce a lowering of the molecular weight equivalent to that from known concentrations of nitrobenzene in natural rubber latex. The molecular weight of the products decreased to an equilibrium value after 10 h of reaction with nitrobenzene. The calculations revealed that a 27.9% substitution of natural rubber latex (300 mL) with Funtumia rubber latex achieved the same result as nitrobenzene in the same polymer at concentrations of 0.5-2.0 wt % of the dry rubber content of the latex after ...
We analyzed the phenotypic variation of baobab (Adansonia digitata L.) fruits from Mali to define the domestication potential of this species. 269 trees, selected from 10 provenances distributed along a rainfall gradient, were characterized. Five fruits were sampled from each tree. Total individual fruit weight was partitioned into shell, pulp, and seed weight. Ratios were calculated between pulp?+?seed and total weight, and between pulp and seed weight. For all the measured fruit traits, we detected significant differences between provenances, as well as between trees from the same provenance. Assuming that the measured traits are under genetic control, the latter facts indicate that there are considerable opportunities for tree selection on a local scale. However, candidate plus trees wi...
Hexavalent chromium in corrosion preventive coating 64 ...To prevent corrosion of rims, weights can be provided with a coating. ...integrated clips brought up technical problems due to corrosion
Geometra'. Scrape Geom- ett_,. Used By: Theoretical. FEM Weight. Apply Linear Delta ...... that the FEM is geometri- cally linear, the differences between ...
In this paper, we investigate the epidemic spreading for SIR model in weighted scale-free networks with nonlinear infectivity, where the transmission rate in our analytical model is weighted. Concretely, we introduce the infectivity exponent $\\alpha$ and the weight exponent $\\beta$ into the analytical SIR model, then examine the combination effects of $\\alpha$ and $\\beta$ on the epidemic threshold and phase transition. We show that one can adjust the values of $\\alpha$ and $\\beta$ to rebuild the epidemic threshold to a finite value, and it is observed that the steady epidemic prevalence $R$ grows in an exponential form in the early stage, then follows hierarchical dynamics. Furthermore, we find $\\alpha$ is more sensitive than $\\beta$ in the transformation of the epidemic threshold and epidemic prevalence, which might deliver some useful information or new insights in the epidemic spreading and the correlative ...
There is conflicting evidence about the effect of parental consanguinity on fetal growth. Previous studies have not always allowed for other factors that are known to affect birth weight, in particular,...Full Text Available
... being designed for projected Minotaur IV launch load environments, with design objectives of light weight, integrated vibration isolation, low shock ...
The primary goal of this study was to assess the association between the full birth weight distribution and prevalence of specific developmental disabilities and related measures of health and special education services utilization in US children. Using data from the 1997?2005 National Health Interview Survey (NHIS) Sample Child Core, we identified 87,578 children 3?17?years of age with parent-reported information on birth weight. We estimated the prevalences of DDs (attention-deficit/hyperactivity disorder [ADHD], autism, cerebral palsy, hearing impairment, learning disability without mental retardation, mental retardation, seizures, stuttering/stammering, and other developmental delay) and several indicators of health services utilization within a range of birth weight categories. We cal...
In this paper a new fuzzy decision-making procedure is developed. Two levels of weightings, called upper and lower weights, are proposed to calculate the fuzzy weightings of different criteria. The preference table is introduced to calculate the upper and lower weights. Also a new method is developed to determine the expected preference values of different alternatives. These values are used for generating the priority list of alternatives. The procedure is applied for providing an emergency electric power distribution, scheduling time table. The IEEE 14-bus standard system and a 14-bus system with four power plants are considered as case studies. Using fuzzy decision-making procedure, the regions with more priorities are more connected to the distribution net, while the maximum consumption criterion is also reasonably respected. (author)
... this correction results In only a email error, since the isothoraal tests wore run at roon tomporcturo, -nd simplifies the reduction of isotherme! ...
Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed ...
Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents regarding their children. Besides an ...
X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast ...
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...
In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation ...
Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and ...
Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...
Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...
The infrared spectrum of the rotovibrational band {ital v}=0{r_arrow}2 of parahydrogen has been observed in the condensed phases down to {ital T}=2 K. In the solid, phonon and roton sidebands exhibit peaks corresponding to those observed in the fundamental. Contributions arising from the reorientation of ortho-H{sub 2} impurities have been detected. The {ital Q}{sub 1}(0)+{ital S}{sub 1}(0) band has been resolved into an asymmetric doublet, and the origin of this latter is discussed. In the liquid phase the observed line shapes include strong translational contributions, and are accounted for by assuming that at short times the excited molecule is encapsulated in the cage of nearest neighbors.
Effects of #gamma#-irradiation on synthetic polymers and paper used as packaging materials for irradiated food have been studied by NMR. Polystyrene, polybutadiene and some copolymers were studied before and after the #gamma#-irradiation treatment and in the presence or absence of antioxidants and stabilisers. In the absence of additives, the effect of #gamma#-irradiation on polystyrene is negligible even irradiating at high doses. In turn, the role of antioxidants and stabilisers is crucial in polybutadiene and butadiene-containing copolymers. Wood pulp paper was also studied by NMR. Preliminary measurements on #gamma#-irradiated wood pulp sheets show a shortening in the T_2 relaxation time component due to the bound water, i.e. some of the bound water is lost. (author)
Phytoplankton community composition, density, and succession were studied in tropical commercial ponds with euryhaline tiger shrimp (Penaeus monodon Fabricius) using green-water technology at two different stocking densities [T1 10 post-larvae (PL) m?2 and T2 15 PL m?2] in one grow-out season (May?October 2005) in Leganes, Iloilo, Philippines. Weekly qualitative and quantitative analyses of phytoplankton were done along with physicochemical analyses of the pond waters. A total of 103 taxa belonging to nine different algal classes were observed. Of these classes, the Chlorophyceae, Cyanophyceae and Bacillariophyceae constituted the great bulk of the phytoplankton population. The two treatments did not show any significant differences in the growth pattern of phytoplankton over time and in t...
The optimal management of men with very favorable clinicopathological factors who develop biochemical recurrence (BCR) after radical prostatectomy (RP) has not been previously reported. Both local and systemic recurrences are unlikely in this cohort. This study examines their management and outcomes. Between October 2000 to March 2010, 1627 men underwent open RP by a single surgeon. In all, 448 (27.5%) met the following criteria for extremely low risk disease: preoperative PSA level <10?ng?ml?1, clinical stage T1c/T2a, Gleason score ?6, estimated cancer volume in the surgical specimen ?5% and no evidence for positive surgical margin. Undetectable PSA was defined as ?0.04?ng?ml?1. BCR was defined as PSA ?0.2?ng?ml...
An effect of laser-cooling of water was observed for the first time with a temperature decrease dT = -2.2 K after irradiation of liquid water surface by a powerful Ar-Xe pulse laser with a pulse energy of about 1 J and wavelength L = 1.73, 2.63 and 2.65 um. The discovered effect can apparently be ascribed to the optical excitation of vibrational states of H2O molecules followed by an endothermic consolidation of chemically active excited molecules into a quasi-stable cluster-like structure. The measured time dependences of the cooling effect show that a typical life time of the new state of water amounts to hours. It has also been shown that the life time of the excited vibrational molecular states due to a radiation trapping effect can be estimated to at least hundreds of seconds.
In parking areas of large extent, the removal of engine exhaust gases, especially of their CO gas components with ventilation plant is mainly done by transverse ventilation over short paths. By their presence, the ventilation ducts required for this purpose often reduce the value of the parking space by restrictions with a consequent reduction of their acceptance by the users. Longitudinal ventilation without ducts can be a remedy in such cases. Depending on the required room air quality in the zones of highest loading, the volume flows with longitudinal removal are no greater than with conventional transverse ventilation. This article is concerned with the different methods of operation of the two systems. (orig./BWI)
The aim of this study was to investigate the effects of pork/beef levels and the casings on the quality properties of semi-dried jerky. The pork/beef levels in the four test formulations were as follows: T-1 (pork: beef=100:0), T-2 (95:5), T-3 (90:10), and T-4 (80:20). After tumbling for 30min with curing solution, the cured meats were stuffed into natural sheep casings, collagen casings, or cellulose casings, and then dried. The restructured jerky with cellulose casing had the lowest water content and the highest protein content, with no significant differences between various formulations. There were no significant differences among all formulations with regard to pH and total microbial counts, and jerky with cellulose casing had the lowest value of water activity. The processing yields ...
A red basil cell line (T2b) rich in rosmarinic acid (RA) was selected for the stable production of anthocyanins (ACs) in the dark. Cell suspension cultures were subjected to mechanical stress through increased agitation (switch from 90 to 150rpm) to determine the relationship between AC and RA accumulation. Cell extracts were analyzed by HPLC and LC-MS, and the resulting data were processed with multivariate statistical analysis. MS and MS/MS spectra facilitated the putative annotation of several complex cyanidin-based ACs, which were esterified with coumaric acid and, in some cases, also with malonic acid. It was also possible to identify various RA-related molecules, some caffeic and coumaric acid derivatives and some flavanones. Mechanical stress increased the total AC and RA contents, ...
The compounds CePdSi_2, CeIrSi_2 and CeRhSn_2 have been synthesized and studied by X-ray diffraction, electrical resistivity and magnetic susceptibility. The magnetic susceptibility of CePdSi_2 exhibits two peaks at 6.8 K and 2.5 K, respectively, indicating two antiferromagnetic phase transitions, while that of CeIrSi_2 shows a broad maximum at 150 K, characteristic of valence fluctuating Ce-compounds. CeRhSn_2 remains paramagnetic down to 5 K. The resistivity of CeIrSi_2 exhibits a T"2 dependence at low temperatures, indicating a Fermi-liquid ground state, while those of CePdSi_2 and CeRhSn_2 shows the presence of Kondo and crystal field effects. (orig.).
With accurate calculation algorithms in inverse planning for beamlet-based intensity modulated radiotherapy (IMRT), it takes time to calculate the dose matrix, which represents the dose distribution of each beamlet element to each voxel for unit fluence. To reduce the calculation time, coarse or approximate algorithms are often a choice, but this results in a final dose distribution that cannot reflect the real value. In addition, it is necessary to test if a coarse algorithm is capable of calculating the dose matrix of beamlets. In this work, simulated dynamics optimization algorithm was applied to optimize the segment weight to minish the dose error from the dose matrix calculation. After calculating the dose matrix by ray-tracing algorithm which takes into account just the primary component of absorbed dose, the original beam profile intensity distribution was optimized by using the simulated dynamics algorithm. Before segmentation, the even-spaced algorithm and ...
Stabilized silver particles comprise particles comprising silver, a short-chain capping agent adsorbed on the particles, and a long-chain capping agent adsorbed on the particles. The short-chain capping agent is a first anionic polyelectrolyte having a molecular weight (Mw) of at most 10,000, and the long-chain capping agent is a second anionic polyelectrolyte having a molecular weight (Mw) of at least 25,000. The stabilized silver particles have a solid loading of metallic silver of at least 50 wt %.
Large (about 200 grams dry weight) and small (about 5 grams dry weight) specimens of the leaf succulent Agave vilmoriniana Berger were grown outdoors at Phoenix, Arizona. Potted plants...Full Text Available
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
Twenty patients with lesions in the trachea or bronchus underwent energy subtraction Fuji computed radiography (FCR). Images obtained were compared with those from conventional FCR (plain FCR). ''Very clear'' images (in which the contour of the trachea and bronchus could be clearly defined) were obtained in 12/22 (55 %) by energy subtraction FCR and in 3/22 (14 %) by plain FCR; ''clear'' images (in which the contour could be defined) in 9/22 (41 %) by energy subtraction FCR and in 18/22 (82 %) by plain FCR; and ''unclear'' images (in which the contour could not be defined) in 1/22 (5 %) by both methods. Energy subtraction FCR, as well as plain FCR, yielded high image quality for the trachea. Energy subtraction FCR was superior to plain films when tumors existed within the trachea. (Namekawa, K.).
Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...
Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).
A multiprocessor architecture inspired by the Disney multiplane camera is proposed. For many applications, this approach produces a natural mapping of processors to objects in a scene. Such a mapping promotes parallelism and reduces the hidden-surface work with minimal interprocessor communication and low-overhead cost. Existing graphics architectures store the final picture as a monolithic entity. The architecture here stores each object's image separately. It assembles the final composite picture from component images only when the video display needs to be refreshed. This organization simplifies the work required to animate moving objects that occlude other objects. In addition, the architecture has multiple processors that generate the component images in parallel. This further shortens the time needed to create a composite picture. In addition to generating images for animation, the ...
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).
This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...
An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more ...
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of ...
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best ...
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...
Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...
A flame retardant tarpaulin is used for protecting equipments upon periodical repairing in places for handling radioactive materials such as a nuclear power plant. It is formed by coating a woven fabric, a knitted fabric or a non-woven fabric with from 100 to 1000% by weight of a composition formed by blending from 3 to 10 parts by weight of red phosphorus and from 7 to 25 parts by weight of melamine sulfate to 100 parts by weight of an ethylene-vinyl acetate copolymer having a vinyl acetate content of from 8 to 28% by weight. Further, it comprises metal hydroxides such as Mg hydroxide and Al hydroxide. Aids such as plasticizers, stabilizers, lubricants and colorants can optionally be blended so long as they do not inhibit the flame retardant effect. It has an excellent flame retardancy, and does not produce poisonous gases or a great amount of ashes when burnt and discarded. It can ...
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...
Power system analysis shows the output from the solar arrays varies as a function .... Each array corresponds to a raw image browse product, which is generated by .... low outgassing, ability to withstand long-term exposure to the space ...
Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to ...
Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available
Many simulation studies in biomedicine are based on a similar sequence of processing steps, starting from images and running through geometric model generation, assignment of tissue properties, numerical...Full Text Available
To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...
The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.
Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.
This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available
This review presents a summary of existing knowledge regarding the impact of testicular cancer along four broad domains, including romantic and sexual relationships, body image, and fertility....Full Text Available
Motivated by the observation that a retinal fundus image may contain some unique geometric structures within its vascular trees which can be utilized for feature matching, in this paper, we proposed...Full Text Available
ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available
Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available
Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available
An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available
To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe ...
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available
Cancer immunotherapies can be guided by cellular imaging techniques, which can identify the presence or absence of immune-cell accumulation in the tumor tissue in-vivo and in real time. This...Full Text Available
OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available
BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available
This volume contains the proceedings of a symposium entitled In Vivo Imaging of Neurotransmitter Function in Brain, Heart, and Tumors'' held August 24--25, 1990 in Montreal Canada. The six individual papers contained herein are separately abstracted and indexed for the database.
BACKGROUND: Although the importance of lymphatic function is well recognized, the lack of real-time imaging modalities limits our understanding of its role in many diseases. In a phase...Full Text Available
Background and Objectives:Sound enamel manifests peak transparency in the near-IR (NIR) at 1310-nm, therefore the near-IR is ideally suited for high contrast imaging...Full Text Available
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...
RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available
A two-channel optical system has been developed to provide spatially resolved simultaneous imaging of singlet molecular oxygen (1O2) phosphorescence and photosensitizer (PS) fluorescence...Full Text Available
The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique...Full Text Available
This paper hopes to share the insights we experienced during designing, building, and running an indexing solution for a large set of radiological reports and images in a production environment for...Full Text Available
Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available
We describe a closed-loop brain-computer interface that re-ranks an image database by iterating between user generated 'interest' scores and computer vision generated visual similarity measures. The interest scores are based on decoding the electroencephalographic (EEG) correlates of target detection, attentional shifts and self-monitoring processes, which result from the user paying attention to target images interspersed in rapid serial visual presentation (RSVP) sequences. The highest scored images are passed to a semi-supervised computer vision system that reorganizes the image database accordingly, using a graph-based representation that captures visual similarity between images. The system can either query the user for more information, by adaptively resampling the database to create additional RSVP sequences, or it can converge to a 'done' state. The done state includes a ...
Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available
Functional imaging has revolutionized the neurosciences. In the pain field it has dramatically altered our understanding of how the brain undergoes significant functional, anatomical and chemical changes...Full Text Available
The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available
Antisense radiopharmaceuticals could be used to image gene expression in the brain in vivo, should these polar molecules be made transportable through the blood–brain barrier....Full Text Available
A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available
We studied 64 ADHD children patients group (4 {approx} 15 ys, mean age: 8 {+-} 2.6 ys. M/F: 52/12) and 12 normal group (6 {approx} 7 ys, mean age: 9.4 {+-} 3.4 ys, M/F: 8/4) of the brain had been used to analysis of blood flow between normal and ADHD group. For analysis of Children ADHD, we used 12 children's mean brain images and made Template image of SPM99 program. In crease of blood flow (P-value 0.05), the result of normalized images to Template image to offer from SPM99 program, showed significant cluster in inter-Hemispheric and occipital Lobe, in the case of normalized images to children template image, showed inter-hemispheric and parietal lobe.
Software for gel image analysis and base-calling in fluorescence-based sequencing consisting of two primary programs, BaseFinder and GelImager, is described. BaseFinder is a framework for trace processing,...Full Text Available
BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available
Retrospective analyses were performed to evaluate the therapeutic efficacy of intra-oral cone (IOC) radiation therapy for carcinoma of the oral tongue, especially about its faculty of local control and complications. Thirty-nine patients with squamous cell carcinoma of the oral tongue were treated with IOC radiation therapy alone or in combination with external irradiation. IOC radiation therapy was given not only for T1 and T2, but also for T3 tumors. Hypofractionation was used for IOC radiation therapy. The 2 year local control rates, including surgical salvage, for T1, T2, T3 and T4 were 100%, 73.3%, 40% and 0%, respectively. The 5 year actuarial survival rates for Stage I, II, III and IV were 100%, 65.3%, 35.4% and 0%, respectively. The incidences of radiation complications, i.e. soft tissue ulceration and osteoradionecrosis, were 42.9% and 2.9%, respectively. It is suggested that relatively high ...
Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).
Disaster impact modeling and analysis uses huge volumes of image data that are produced immediately following a natural or an anthropogenic disaster event. Rapid damage assessment is the key to time critical decision support in disaster management to better utilize available response resources and accelerate recovery and relief efforts. But exploiting huge volumes of high resolution image data for identifying damaged areas with robust consistency in near real time is a challenging task. In this paper, we present an automated image analysis technique to identify areas of structural damage from high resolution optical satellite data using features based on image content.
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging
/sup 99m/Tc biliary imaging was performed on a 34-year-old woman who was being investigated for suspected cholelithiasis. A left-sided liver was detected. On subsequent radionuclide imaging, partial visceral situs inversus and asplenia were demonstrated. Extensive roentgenographic investigation, ECG, echocardiogram, and laparotomy confirmed the radionuclide findings. Asplenia syndrome may exist without cardiovascular abnormalities and thus be undiscovered. Radionuclide imaging is important in the diagnosis of this syndrome.
A carbon nanotube (CNT) tip, which assembled on the sharp end of a Si tip by dielectrophoresis, was structurally modified using focused ion beam (FIB). We described the imaging characterization of the FIB-modified CNT tip in noncontact AFM mode in terms of wear, deep trench accessibility, and imaging resolution. Compared to a conventional Si tip, the FIB-modified CNT tip was superior, especially for prolonged scanning over 10 h. We conclude that modified CNT tips have the potential to obtain high-quality images of nanoscale structures.
... is the sensor that converts incoming photons into a ... with CCD foundries to acquire such a sensor. ... 2007, Journal of Spacecraft and Rockets, 44, 910 ...
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).
The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....