WorldWideScience
1

Role of MRI in the diagnostic evaluation of parotid diseases  

International Nuclear Information System (INIS)

MRI findings in 13 patients with monolateral parotid tumor were compared with US, sialographic and CT findings. MRI did not allow an accurate diagnosis in 2 patients with diffuse chronic parotitis. MRI was superior to CT in 1 case in defining the intraglandular site of the lesion, and in 2 patients in showing the extraglandular involvement. MRI proved to be superior to CT thanks to its contrast resolution and to multiplanar imaging. MRI high contrast resolution made it possible to demonstrate neoplastic lesions of 4 mm in diameter. The lesion has low signal intensity on T1-weighted images and high signal intensity on T2-weighted. Parotid tumors cannot be characterized by signal intensity alone: only morphology allows to discriminate between benign and malignant lesions. To conclude, US is a screening ...

1988-01-01

2

MRI in pleural diseases  

International Nuclear Information System (INIS)

The MRI and CT appearances in 48 patients with histologically confirmed benign and malignant pleural abnormalities were compared retrospectively. Abnormal pleural changes were shown in 47 out of the 48 patients by high signal intensity of the pleura in T_2-weighted sequences and in contrast enhanced T_1-weighted sequences on MRI. CT showed abnormalities in 45 out of 48 patients. Delineation of pleural and pulmonary changes by CT was possible in 13 out of 23 cases, and pleural disease from effusions in 15 out of 28 cases. T_2-weighted MRI was successful in 14 out of 23 and 4 out of 28 cases, respectively. T_1-weighted images after contrast were successful in 20 out of 23 and 22 out of 28 cases, respectively. Indications of malignant pleural disease were the presence of mediastinal or circumferential ...

3

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled ...

2000-05-01

4

Computerized Tomography versus unenhanced and enhanced fast MRI sequences in the study of liver metastases: Qualitative and quantitative analyses  

International Nuclear Information System (INIS)

The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically ...

1997-01-01

5

MRT of the abdomen in combination with enteroclysis in Crohn disease with oral and intravenous Gd-DTPA  

International Nuclear Information System (INIS)

60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A ...

6

T1 and T2 relaxivities of succimer-coated MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

International Nuclear Information System (INIS)

Superparamagnetic MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r2/r1, for MnFe2O4, Fe3O4 and CoFe2O4 were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T2 contrast agents for MRI.

2009-12-01

7

MRI findings of the brain in high-voltage electrical burn patient: case report  

Energy Technology Data Exchange (ETDEWEB)

We report the delayed sequelae arising in a case of electrical injury, reviewing the literature on the subject and focusing on the MRI findings of the brain. A 23-year-old male suffered burns to the left parietal scalp, both feet, and the anterior chest wall. Neurological symptoms and MRI abnormalities appeared 14 days after the insult and continued for about three months. T1-weight MR images demonstrated homogeneous hypointensity, while T2-weighted images depicted hyperintense finger-like projections. Contrast-enhanced T1-weighted images demonstrated strong band-like enhancement, indicating meningeal hyperemia. Follow-up MR imaging showed that the lesion had disappeared, indicating that the cerebral edema and meaningeal hyperemia were reversible.

2003-05-01

8

Diagnostic value of MRI for hepatic hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To investigate the value of MRI in the diagnosis of hepatic hilar cholangiocarcinoma. Methods: Sixty-four patients with hepatic hilar cholangiocarcinomas confirmed by surgery or pathology underwent MRI using a 1.5-T superconductive MR system including conventional unenhanced MRI, MRCP and dynamic contrast-enhanced MRI with Gd-DTPA. Results: Dilatation of the intrahepatic biliary tree with narrowing, occlusion or filling defects in the hepatic hilar bile ducts was noted in all 64 cases. Unenhanced MR[ showed T_1- and T_2-hyperintense hilar masses in 42 patients and was normal in the remaining 22 patients. The hilar masses demonstrated slow, progressive and delayed enhancement patterns. There was enhancement of the thickened bile duct wall with luminal narrowing in the 22 patients without hilar masses. Conclusion: The characteristic ...

2010-02-01

9

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas  

International Nuclear Information System (INIS)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by ...

2003-03-01

10

Dura thickening adjacent to intracranial tumors on MRI. Histologically correlation  

International Nuclear Information System (INIS)

Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T_2-weighted spin echo (SE) images as well as T_1-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 ...

11

Comparison of turbo inversion recovery magnitude (TIRM) with T2-weighted turbo spin-echo and T1-weighted spin-echo MR imaging in the early diagnosis of acute osteomyelitis in children  

Energy Technology Data Exchange (ETDEWEB)

Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ...

1998-11-01

12

Modern visualization of the liver with MRI - current trends and future perspectives; Moderne Leberbildgebung mit der MRT - aktuelle Trends und Zukunft  

Energy Technology Data Exchange (ETDEWEB)

This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the liver can be expected with use of the 3T ...

2004-12-01

13

MRT of the abdomen in combination with enteroclysis in Crohn disease with oral and intravenous Gd-DTPA; MRT des Abdomens in Kombination mit der Enteroklyse bei Morbus Crohn unter Verwendung von oralem und intravenoesem Gd-DTPA  

Energy Technology Data Exchange (ETDEWEB)

60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A ...

1998-01-01

14

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system  

International Nuclear Information System (INIS)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI ...

15

Multi-modality imaging of uveal melanomas using combined PET/CT, high-resolution PET and MR imaging  

Energy Technology Data Exchange (ETDEWEB)

We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded ...

2008-07-01

16

In vitro MRI of brain development  

International Nuclear Information System (INIS)

In this review, we demonstrate the developmental appearance, structural features, and reorganization of transient cerebral zones and structures in the human fetal brain using a correlative histological and MRI analysis. The analysis of postmortem aldehyde-fixed specimens (age range: 10 postovulatory weeks to term) revealed that, at 10 postovulatory weeks, the cerebral wall already has a trilaminar appearance and consists of: (1) a ventricular zone of high cell-packing density; (2) an intermediate zone; (3) the cortical plate (in a stage of primary consolidation) with high MRI signal intensity. The anlage of the hippocampus is present as a prominent bulging in the thin limbic telencephalon. The early fetal telencephalon impar also contains the first commissural fibers and fornix bundles in the septal area. The ganglionic eminence is clearly visible as an expanded continuation of the proliferative ventricular zone. The basal ganglia showed an ...

2006-02-01

17

MR imaging of experimental intramuscular hemorrhage at 0. 02 T; Contrast enhancement with Gd-DOTA  

Energy Technology Data Exchange (ETDEWEB)

Intramuscular hermorrhage was induced by injecting autologous blood into the paraspinal muscle of 8 rabbits. In order to evaluate the time-dependent changes of hemorrhage observed on MRI, the animals were imaged at different stages of blood resolution at 0.02 tesla (T), and control examined with ultrasound using a 7.5 MHz linear transducer. Six inversion recovery sequences (TR=1 000 ms. TE=30 ms, and TI=18, 48, 148, 201, 302, and 398 ms) were used for the invivo calculation of T1 relaxation times. IR 1 000 (398)/30 imaging was performed before and after the Gd-DOTA administration. The hemorrhage was evident on MR images throughout the study, especially on the T2 weighted (SE 1 000/100) images. MRI showed the healing lesion longer than ultrasound. The T1 relaxation time increased during the time of resolution. Lesions on days 4 to 7 enhanced in intensity after the injection of Gd-DOTA. (orig.).

1990-09-01

18

Primary malignant lymphoma of the brain; Primaere maligne Lymphome des Gehirns  

Energy Technology Data Exchange (ETDEWEB)

Primary malignant lymphoma of the brain is a disease of unknown etiology, which is increasing in incidence and has an unfavorable prognosis. Despite the lack of specific changes on CT or MRI in most cases, these procedures may typically facilitate the diagnosis: A focal-enhancing mass with subependymal spread on CT or MRI and hyperattenuation on nonenhanced CT are the most reliable features in the diagnosis of primary malignant lymphoma of the brain. Peritumoral edema and mass effect are usually not prominent features. On unenhanced CT scans they usually appear homogeneously isodense to mildly hyperdense relative to the gray matter. On MRI these tumors are slightly hypointense on T1-weighted images and slightly hpyerintense on PD- and T2-weighted images relative to the gray matter. On CT and MRI enhancement is usually homogeneous. ...

1997-01-01

19

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas; CT und MRT des erworbenen Cholesteatoms: Prae- und postoperative Bildgebung  

Energy Technology Data Exchange (ETDEWEB)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by ...

2003-03-01

20

Usefulness of MRI in diagnosis of hepatocellular carcinoma (HCC)  

Energy Technology Data Exchange (ETDEWEB)

Sixty-six cases of histologically proven hepatocellular carcinomas (HCC) were studied by MRI. Detectability was better by MRI than by CT, especially in the tumor under 2 cm in diameter. The capsule was detected in all cases of HCC over 3 cm in diameter. The capsule was able to be diagnosed only by dynamic MRI study in some cases. High intensity on the T1-weighted image and iso or low intensity on the T2-weighted image suggested that the nodule was adenomatous hyperplasi (AH) or well differentiated HCC. MRI is concluded to be an essential modality in the diagnosis of HCC. (author).

1992-06-01

21

Magnetic resonance imaging in acute intractional tuberculosis  

International Nuclear Information System (INIS)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).

22

Diagnosis of plasmocytomas using magnetic resonance imaging  

International Nuclear Information System (INIS)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is ...

2000-08-01

23

Synthesis and characterization of PVP-coated large core iron oxide nanoparticles as an MRI contrast agent  

UK PubMed Central (United Kingdom)

The purpose of this study was to synthesize biocompatible polyvinylpyrrolidone (PVP)-coated iron oxide (PVP-IO) nanoparticles and to evaluate their efficacy as a magnetic resonance imaging (MRI)...Full Text Available

2008-04-01

24

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle  

International Nuclear Information System (INIS)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by ...

2003-03-01

25

MRI in preoperative evaluation of chronic paranasal sinusitis - a comparison with CT  

International Nuclear Information System (INIS)

Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T_2-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts ...

2001-04-01

26

PET and MR imaging in a neuro-Behcet syndrome  

Energy Technology Data Exchange (ETDEWEB)

Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).

1989-11-01

27

Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development  

International Nuclear Information System (INIS)

Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains ...

2002-08-01

28

Diffusion-weighted MRI suggests the coexistence of cytotoxic and vasogenic oedema in a case of deep cerebral venous thrombosis  

Energy Technology Data Exchange (ETDEWEB)

We report a 20-year-old woman who suffered headaches before presenting with a state of fluctuating vigilance. MRI showed diffuse high signal in the basal ganglia bilaterally on diffusion- and T2-weighted images, which had areas of both low and high apparent diffusion coefficient, presumed to correspond to cytotoxic and vasogenic oedema. MR venography showed no flow in the deep cerebral veins or straight sinus. Heparin was given, with clinical recovery. On follow-up MRI, the appearances became normal. (orig.)

2000-10-01

29

CT and MRI characteristica of tumours of the temporal bone and the cerebello-pontine angle; CT und MRT tumoroeser Veraenderungen des Schlaefenbeins  

Energy Technology Data Exchange (ETDEWEB)

Tumours lesions of the temporal bone and of the cerebello-pontine angle are rare.This tumours can be separated into benign and malignant lesions. In this paper the CT and MRI characteristica of tumours of the temporal bone and the cerebello-pontane angle will be demonstrated. High resolution CT (HRCT) as usually performed in the axial plane are using a high resolution bone window level setting, coronal planes are the reconstructed from the axial data set or will be obtained directly. With the MRI FLAIR sequence in the axial plane the whole brain will be scanned either to depict or exclude a tumour invasion into the brain. After this,T2-weighted fast spin echo sequences or fatsuppressed inversion recovery sequences in high resolution technique in the axial plane will be obtained from the temporal bone and axial T1-weighted spinecho sequences before and after the intravenous application of ...

2003-03-01

30

Dynamic NMR effects in breast cancer dynamic-contrast-enhanced MRI  

UK PubMed Central (United Kingdom)

The passage of a vascular-injected paramagnetic contrast reagent (CR) bolus through a region-of-interest affects tissue 1H2O relaxation and thus MR image intensity. For longitudinal...Full Text Available

2008-11-18

31

Diagnosis of plasmocytomas using magnetic resonance imaging; Diagnostik des Plasmozytoms mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis ...

2000-08-01

32

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

33

Lacrimal gland masses on CT and MRI: a report of four cases  

International Nuclear Information System (INIS)

In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.).

34

Contrast factors in nuclear magnetic resonance imaging  

International Nuclear Information System (INIS)

In Nuclear Magnetic Resonance (NMR) imaging, contrast is dependent on the emission of radiofrequency waves by atomic nuclei, balanced by several parameters. The high information content of NMR images is due to the multiplicity of its parameters. However, this advantage introduces a difficulty in the interpretation of the contrast. There are three contrast parameters for each tissue: hydrogen nuclei density; relaxation time T1; relaxation time T2. Contrast may be enhanced towards any of these parameters by increasing the emission of radiowaves by atomic nuclei using particular pulse sequences.

1985-01-01

35

Staging of osteochondritis dissecans of the knee and ankle with MRI. Comparison with conventional radiography and arthroscopy  

International Nuclear Information System (INIS)

A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T_1- and T_2-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG).

36

Multimodal MRI assessment of damage and plasticity caused by status epilepticus in the rat brain  

British Library Electronic Table of Contents (United Kingdom)

Summary Status epilepticus or other brain-damaging insults launch a cascade of events that may lead to the development of epilepsy. MRI techniques available today, including T2- and T1-weighted imaging, functional MRI, manganese enhanced MRI (MEMRI), arterial spin labeling (ASL), diffusion tensor imaging (DTI), and phase imaging, can detect not only damage caused by status epilepticus but also plastic changes in the brain that occur in response to damage. Optimal balance between damage and recovery processes is a key for planning possible treatments, and noninvasive imaging has the potential to greatly facilitate this process and to make personalized treatment plans possible.

2011-01-01

37

MRI imaging of fetal neck masses with airway compromise: utility in delivery planning  

International Nuclear Information System (INIS)

We present two cases of fetal neck masses that were initially diagnosed by ultrasound and further evaluated with prenatal MRI. MRI findings aided in further delineating the neck masses, increasing confidence in the final diagnosis (cervical teratoma and cystic hygroma). With the fetal airway typically filled with fluid that is of high signal on T2-weighted sequences, MRI images in three planes could identify whether the fetal larynx and trachea were partially or completely compressed by the neck tumor. This information was particularly useful in determining if a controlled delivery such as ex utero intrapartum treatment (EXIT) was necessary and aided the surgeons in planning their approach to establishing airway control in the delivery room. (orig.)

2001-10-01

38

MRI with pathogenic correlation of small renal cell carcinoma  

Energy Technology Data Exchange (ETDEWEB)

MRI, ultrasonography and angiography were performed on 24 cases with small renal cell carcinoma, and data were compared with pathological architecture type. An average diameter of cancer was 20.8 mm (10-30 mm). Each tumor was pathologically classified into four architecture types: alveolar type (15 cases), papillary type (5 cases), tubular type (3 cases) and cystic type (1 case). In comparison with renal cortex alveolar type renal cell carcinoma showed equal or low signal in T1-weighted images and equal or high signal in T2-weighted images. Papillary and tubular types showed high signal in T1-weighted images, and low signal in T2-weighted images. In alveolar type, many cases showed equal echo in ultrasonography and hypervascularity in angiography, and in papillary and tubular types, many cases showed high echo and hypovascularity. There were many cases with papillary type small cell ...

1999-11-01

39

Ultrashort echo time MRI of cortical bone at 7 tesla field strength: A feasibility study  

British Library Electronic Table of Contents (United Kingdom)

AbstractPurpose: To implement and examine the feasibility of a three-dimensional (3D) ultrashort TE (UTE) sequence on a 7 Tesla (T) clinical MR scanner in comparison with 3T MRI at high isotropic resolution. Materials and Methods: Using an in-house built saddle coil at both field strengths we have imaged mid-diaphysial sections of five fresh cadaveric specimens of the distal tibia. An additional in vivo scan was performed at 7 Tesla using a quadrature knee coil. Results: Using the same type of saddle coil at both field strengths, a significant increase in SNR at 7T compared with 3T (factor 1.7) was found. Significantly shorter T2* values were found at the higher field strength (T2* = 552.2 126 s at 7T versus T2* = 1163 391 s at 3T). Conclusion: UHF MRI at 7T has great potential for imaging...

2011-01-01

40

An intracranial aspergilloma with low signal on T2-weighted images corresponding to iron accumulation  

Energy Technology Data Exchange (ETDEWEB)

We present a case of cerebral aspergillosis in an immunocompetent patient. The MRI signal characteristics were compared with the histologic findings. Irregular low-signal zones were demonstrated between the wall of the abscess and the central necrosis on T2-weighted images; the pathology specimen revealed concentrated iron in these transitional zones but no hemosiderin. Iron is an essential element for the growth of fungal hyphae. The low-signal zones may represent the areas where there was active proliferation of aspergillus, and the unique location of the low signal may be a helpful imaging characteristic for the diagnosis of an aspergillus abscess. (orig.)

2001-07-01

41

Nuclear magnetic resonance imaging of the abnormal live rat and correlations with tissue characteristics  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance (NMR) images of live rats with sterile and pyogenic abscesses, hematomas, and various implanted and spontaneous neoplasms demonstrated good contrast differentiation between pathologic and surrounding normal tissues. This differentiation was maximal when both the T1 and T2 tissue relaxation times were used as criteria. Neoplasms have a broad range of T1 and T2 values and may be confused with abscesses or hematomas. Tissue rate constants (1/T1 and 1/T2) are mainly dependent on total water content, the exception being fat, which has a 1/T2 value much shorter than that expected on the basis of water content alone.

1981-10-01

42

Magnetic resonance appearance of peripheral nerve sheath tumors  

International Nuclear Information System (INIS)

Magnetic resonance imaging (MRI) was used to evaluate 22 histological proven peripheral nerve sheath tumors, approximately two-thirds of which arose in the lower extremity. The histologic distribution was as follows: 12 schwannomas, 7 neurofibromas, and 3 malignant peripheral nerve sheath tumors (2 of which occurred in patients with neurofibromatosis). Most lesions demonstrated an intermediate to moderately bright signal on T_1-weighted images and were minimally inhomogeneous. All lesions were moderately bright on T_2-weighted images, again with variable inhomogeneity. The extent of the tumor was best assessed on proton-density- and T_2-weighted images. Smooth margins were noted in 19 lesions. Of the 3 remaining lesions, 2 were malignant (but had been subjected to biopsy prior to MRI), and the other lesion was a plexiform neurofibroma. MRI ...

43

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors ...

2008-06-01

44

Visualization of the salivary glands. CT and MRI  

International Nuclear Information System (INIS)

For the evaluation of diseases of salivary origin, ultrasound and/or sialography is recommended instead of MRI. In cases of salivary tumor, ultrasound may be helpful in delineating superficial tumors. For small tumors no further imaging is needed. When dealing with a large tumor or a tumor in the deep lobe of the parotid gland, MRI is the preferred imaging method. Not only does MRI provide a large variety of soft tissue signal differences, but also the multiplanar facilities are helpful in delineating the extent of the tumor, whether located in the submandibular, sublingual, or parotid gland. Skull base invasion is often well seen by MRI. Subtle changes may be missed and in those cases CT is recommended to exclude or prove destruction of the skull base. For the evaluation of patients presenting with a recurrent pleomorphic adenoma, MRI is recommended in all patients. ...

45

Dissection of the thoracic aorta - role of CT and MRT following aortic replacement  

International Nuclear Information System (INIS)

Dynamic CT and MRT were performed in 21 patients who had undergone prosthetic replacement of the aorta because of dissection of the thoracic aorta. There is no difference between MRI and dynamic CT in the demonstration of a persistent intimal flap, the formation of a thrombus and the assessment of the aortic diameter in patients who underwent surgery for thoraco-abdominal aortic dissection. MRI, however, is superior in the identification of the true and false lumen and the demonstration of the distal anastomotic site. The major advantages of MRI are that there is no need for intravenous contrast agents, that it is high sensitive to flow phenomena, and that it can demonstrate the aortic arch and the ascending aorta on sagittal oblique sections. The major disadvantages of MRI are the limited access to the patient during the procedure, and the inability to examine patients fitted with ...

46

Correlation of MRI and histomorphological findings in bone marrow oedema syndrome of the hip  

Energy Technology Data Exchange (ETDEWEB)

In 15 patients (16 hip joints) we found the clinical and radiological signs of BMOS. On T1-weighted MRI images areas of low signal intensity could be observed in the head, neck and the intertrochanteric region of the femur in various extensions. These areas showed a significant increase in signal intensity on the T2-weighted images. Because pain was resistant to conservative therapy all these patients were treated by core decompression of the femoral head in a prospective study. Bone cores were evaluated histologically using undecalcified sections and quantitative microradiography. The existence of intramedullary oedema in exactly the regions exhibiting the MRI pattern of bone marrow oedema was verified histologically; however, bone and marrow changes similar to those of early avascular necrosis (AVN) were also visible. (orig.)

1993-10-01

47

Incidence of lesions as described by MRI in focal epilepsy of frontal and temporal onset; Inzidenz kernspintomographisch erfassbarer Laesionen bei der Abklaerung fokaler Epilepsien frontalen und temporalen Ursprunges  

Energy Technology Data Exchange (ETDEWEB)

Aim: Today, MRI is an integral part of the presurgical evaluation of patients suffering from partial epilepsy. These patients frequently show focal morphological abnormalities with potential epileptogenic character and surgical resection of these lesions is associated with superior postsurgical outcome as to seizure frequency. Apart from easily detectable defects, such as post-traumatic lesions or cerebral infarction, as wide variety of mainly small abnormalities can be detected using MRI. Methods: In this study, 484 patients suffering from partial epilepsy of temporal or frontal onset were evaluated for the incidence of different lesions in this population. Results: All lesions found were included without evaluating their potential epileptogenicity, which remains to be proven using other procedures (EEG, SPECT, PET, etc.). Involvement of the hippocampal formation was a major finding in temporal lobe epilepsy, which could be detected as ...

1997-09-01

48

Development of a geometrically accurate imaging protocol at 3 Tesla MRI for stereotactic radiosurgery treatment planning  

International Nuclear Information System (INIS)

The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T ...

2010-11-21

49

The diagnostic value of MRI and gadolinium-DTPA compared with CT for the diagnosis of bladder tumours  

International Nuclear Information System (INIS)

In a prospective study, 58 patients with carcinomas of the bladder were examined by CT and MRI; in 48, gadolinium-DTPA was administered intravenously. MRI provided exact staging in 89%, compared with 80% with CT. There was 13% over-staging with CT and 11% with MRI. MRI, unlike CT did not result in any under-staging. In 36 patients a quotient could be calculated from the signal intensity of the tumour and surrounding soft tissues both before and after the intravenous contrast medium and the increased quotient after contrast administration could be estimated. There was a significant increase in the tumour/muscle quotient with a mean of 72#+-#22% (minimum 43%, maximum 153%), corresponding to a marked increase of the signal form the tumour when compared with the precontrast images. This had the following advantages compared with CT: Accurate differentiation between ...

50

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity  

International Nuclear Information System (INIS)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in ...

51

Nodular fasciitis: correlation of MRI findings and histopathology  

Energy Technology Data Exchange (ETDEWEB)

Objective: To compare the histopathology of nodular fasciitis (NF) with the magnetic resonance imaging (MRI) findings in order to evaluate the basis of the MR signal characteristics. Design and patients: Ten patients with NF, nine females and 1 male, with an age ranging from 13 to 58 years (mean 26.8 years) were studied. MRI findings, available in all 10 patients, were compared with the histopathology in nine patients, and an area-to-area comparative study of the whole specimen section histopathology and MRI was performed in two patients. Results: On the basis of an excisional biopsy or resection specimen, the nine lesions were classified into myxoid (n=4), cellular (n=3) and fibrous (n=2) subtypes. Four myxoid lesions with a subcutaneous location showed a homogeneous SI comparable with muscle on T1-weighted images, high SI on T2-weighted images, and had homogeneous enhancement. One ...

2002-03-01

52

Synovial cysts of the lumbar spine: CT and MRI correlations  

Energy Technology Data Exchange (ETDEWEB)

Intraspinal synovial cysts were diagnosed in six patients during a 5-year period and retrospectively studied. Plain films of the lumbar spine showed degenerative changes in all patients. Lumbar myelography showed a posterior and lateral defect caused by extradural compression. Using CT without contrast enhancement established the diagnosis in five of the six patients. In four cases MRI was performed, three before and after injection of gadolinium diethyline-triamine penta-acetic acid (Gd-DTPA). Including the patient with a false-negative CT, MRI was positive in all patients. (orig.)

1994-08-01

53

Enhancing fraction measured using dynamic contrast-enhanced MRI predicts disease-free survival in patients with carcinoma of the cervix  

UK PubMed Central (United Kingdom)

Background:There is a need for simple imaging parameters capable of predicting therapeutic outcome.Methods:This retrospective study analysed 50 patients...Full Text Available

2010-01-05

54

MRI in definition of bleeding source, lesion pattern and therapy in haemarthros of the knee  

International Nuclear Information System (INIS)

Patients with haemarthros of the knee were examined by MRI and arthroscopy to identify the bleeding source and to determine surgical or conservative therapy. A prospective study was performed on 120 patients who underwent MRI and arthroscopy, point lesions and bleeding sources were documented separately on a standardised form. Arthroscopy demonstrated a ruptured anterior cruciate ligament in 86%, meniscal tears in 55%, disruption of collateral ligaments in 17%, osteochondral lesions in 5% and tears of capsule or plicae in 13%. Disruption of cruciate ligaments caused haemorrhage in all but three cases. In contrast, only meniscal tears located very adjacent to the meniscal basement had bled. Those types of osteochondral lesions caused haemorrhage characterised on MRI by destruction of the subchondral plate and overlying cartilage. Severe lesions of the knee were diagnosed by MRI in ...

55

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system; Hochaufloesendes Ganzkoerpertumorstaging unter Verwendung paralleler Bildgebung im Vergleich zur PET-CT. Erste Erfahrungen auf einem 32-Kanal-MRT-System  

Energy Technology Data Exchange (ETDEWEB)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI ...

2004-09-01

56

Functional MRI of the visual cortex and visual testing in patients with previous optic neuritis.  

DEFF Research Database (Denmark)

The volume of cortical activation as detected by functional magnetic resonance imaging (fMRI) in the visual cortex has previously been shown to be reduced following optic neuritis (ON). In order to understand the cause of this change, we studied the cortical activation, both the size of the activated area and the signal change following ON, and compared the results with results of neuroophthalmological testing. We studied nine patients with previous acute ON and 10 healthy persons served as controls using fMRI with visual stimulation. In addition to a reduced activated volume, patients showed a reduced blood oxygenation level dependent (BOLD) signal increase and a greater asymmetry in the visual cortex, compared with controls. The volume of visual cortical activation was significantly correlated to the result of the contrast sensitivity test. The BOLD signal increase correlated significantly to both the results of the ...

2002-01-01

57

Ultrasmall superparamagnetic iron oxides (USPIOs): a future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)?  

UK PubMed Central (United Kingdom)

Gadolinium (Gd) based contrast agents (GBCAs) in magnetic resonance imaging (MRI) are used in daily clinical practice and appear safe in most patients; however, nephrogenic systemic fibrosis...Full Text Available

2009-03-01

58

Soft tissue signal abnormality associated with eosinophilic granuloma. Correlation of MR imaging with pathologic findings  

Energy Technology Data Exchange (ETDEWEB)

Six patients with eosinophilic granuloma were studied retrospectively in order to correlate the MRI appearances with the pathology. Ages ranged from 2 years 6 months to 11 years. The bones involved were the humerus, ulna, radius, femur, clavicle and ilium. Plain films, MRI and pathology specimens were obtained. A lytic lesion with indistinct margins, endosteal erosions and periosteal reaction was seen in all cases on plain radiographs. Bone marrow signal was decreased on T1-weighted images and increased on T2-weighted images throughout the bony lesion in all cases. T2-weighted images showed extensive soft-tissue abnormalities suggesting inflammatory changes in four cases. In two cases abnormalities were limited. Extensive changes correlated histologically with an early phase lesion. Localized minor changes were associated with a mid-phase lesion. Inflammatory ...

1994-09-01

59

MR findings of central nervous system involvement in acquired immunodeficiency syndrome patient : a report of two cases  

Energy Technology Data Exchange (ETDEWEB)

Central nervous system (CNS) manifestations in acquired immunodeficiency syndrome (AIDS) patients are an early and common feature. The spectrum of AIDS-related CNS diseases are encephalitis caused by the human immunodeficiency virus(HIV) itself, opportunistic infection, infarct and malignancy. We experienced two cases of CNS involvement in AIDS and they were serologically diagnosed as HIV encephalitis and CNS toxoplasmosis, respectively. In the case of the HIV encephalitis patient, brain MRI showed a non-enhancing lesion with high signal intensity on T2WI and low signal on T1WI and there was no mass effect on the right frontal lobe, periventricular white matter, splenium of the corpus callosum or bilateral basal ganglia. In the other case of CNS toxoplasmosis, MR showed multiple nodular and rim enhanced mass lesions in the right basal ganglia, thalamus and periventricular white matter, which were of low signal intensity on ...

1996-10-01

60

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided into 16 fine clusters. The final tissue classifications were ...

61

MRI of normal fetal brain development  

International Nuclear Information System (INIS)

Normal fetal brain maturation can be studied by in vivo magnetic resonance imaging (MRI) from the 18th gestational week (GW) to term, and relies primarily on T2-weighted and diffusion-weighted (DW) sequences. These maturational changes must be interpreted with a knowledge of the histological background and the temporal course of the respective developmental steps. In addition, MR presentation of developing and transient structures must be considered. Signal changes associated with maturational processes can mainly be ascribed to the following changes in tissue composition and organization, which occur at the histological level: (1) a decrease in water content and increasing cell-density can be recognized as a shortening of T1- and T2-relaxation times, leading to increased T1-weighted and decreased T2-weighted intensity, respectively; (2) the ...

2006-02-01

62

Magnetic resonance imaging in acute intractional tuberculosis; Magnetresonanztomographie bei akuter intrakranieller Tuberkulose  

Energy Technology Data Exchange (ETDEWEB)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im ...

1994-12-31

63

T{sub 1} and T{sub 2} relaxivities of succimer-coated MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

Energy Technology Data Exchange (ETDEWEB)

Superparamagnetic MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r{sub 2}/r{sub 1}, for MnFe{sub 2}O{sub 4}, Fe{sub 3}O{sub 4} and CoFe{sub 2}O{sub 4} were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T{sub 2} contrast agents for MRI.

2009-12-15

64

MR imaging of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Magnetic resonance (MR) images of 18 cases of hilar cholangiocarcinoma were evaluated to compare the effectiveness of Gd-DTPA with that of high dose contrast enhancement computed tomography (HCE-CT) in detecting the primary tumor. The primary tumor was demonstrated as having slightly low intensity compared with liver parenchyma and high intensity compared with the delated bile duct on T1-weighted images. In contrast, MRI using Gd-DTPA, which was carried out in five cases, revealed intense enhancement of the tumor. As the differentiation between cholangiocarcinoma and dilated bile duct was difficult, it was concluded that the use of Gd-DTPA improves the efficacy of MRI in diagnosing cholangiocarcinoma. Gd-DTPA was also effective in differentiating the growth pattern of the tumor: the infiltrating type was demonstrated as thickening of the wall of the bile duct, the polypoid type as a soft tissue mass in ...

65

MR imaging and MR cholangiopancreatography in the preoperative evaluation of hilar cholangiocarcinoma: correlation with surgical and pathologic findings  

International Nuclear Information System (INIS)

The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weighted images (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted ...

2008-10-01

66

The use of magnetic resonance imaging for diagnosis and staging of renal cell carcinoma  

International Nuclear Information System (INIS)

The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).

67

Fetal MRI of pathological brain development  

International Nuclear Information System (INIS)

Because of the superior tissue contrast, high spatial resolution, and multiplanar capabilities, fetal magnetic resonance imaging (MRI) can depict fetal brain pathologies with high accuracy. Pathological fetal brain development may result from malformations or acquired conditions. Differentiation of these etiologies is important with respect to managing the actual pregnancy or counseling future pregnancies. As a widened ventricular system is a common hallmark of both maldevelopment and acquired conditions, it may cause problems in the differential diagnosis. Fetal MRI can provide detailed morphological information, which allows refinement of the diagnosis of ventricular enlargement in a large number of cases. Systematic work-up of morphological details that may be recognized on MR images provides an approach for achieving a correct diagnosis in cases of ventricle enlargement. (orig.)

2006-02-01

68

Influence of contrast-enhanced CT and MRI with or without SPIO particles on therapy and therapy costs for patients with focal liver disease  

International Nuclear Information System (INIS)

Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and ...

2000-03-01

69

Value of contrast-enhanced MRI of breast after silicone implant; Wertigkeit der Kontrastmittelmagnetresonanztomographie der Mamma bei Wiederaufbau mittels Implantat  

Energy Technology Data Exchange (ETDEWEB)

Early recognition of recurrence and work-up of clinically indeterminate lesions may be impaired after reconstruction with silicone implants due to superimposition of the implant or to scarring. This study was undertaken to evaluate the use of contrast-enhanced MRI in patients with silicone implant after breast cancer. Contrast-enhanded MRI was offered to 169 patients. Comparative two- to three-view mammography was also performed in 169 patients, as well as comparative sonography in 144 patients. Conventional imaging and clinical examination detected only 8/13 recurrences, whereas 12/13 were detected by MRI. One recurrence had been visible as a strongly enhancing 2-mm dot in a previous examination (2 years before), but was not called. It was therefore counted as false negative. In addition, multicentricity was detected by MRI alone in two of three cases. ...

1997-09-01

70

Comparative evaluation of Computed Tomography and Magnetic Resonance Imaging (1.5 T) in the detection of brain metastases  

International Nuclear Information System (INIS)

Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of ...

1991-01-01

71

Anatomical changes after radical surgery and reconstruction with pedunculated or revascularized flaps in advanced head and neck cancer: CT and MR features; Modificazioni anatomiche dopo chirurgia radicale e ricostruzione con lembi peduncolati o rivascolarizzati nei tumori cervico-facciali negli stadi avanzati: Aspetti con Tomografia Computerizzata e Risonanza Magnetica  

Energy Technology Data Exchange (ETDEWEB)

January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair the surgical defect: jejunal and radial ...

1997-04-01

72

Anatomical changes after radical surgery and reconstruction with pedunculated or revascularized flaps in advanced head and neck cancer: CT and MR features  

International Nuclear Information System (INIS)

January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair the surgical defect: jejunal and radial ...

1997-01-01

73

Cranial MRI of neurologically impaired children suffering from neonatal hypoglycaemia  

International Nuclear Information System (INIS)

Background. Metabolic disturbances such as anoxia and hypoglycaemia are important in causing maldevelopment of the neonatal brain. While there have been some pathology studies of the effects of neonatal hypoglycaemia on brain development, reports of MRI findings in such infants have been rare. Objectives. To describe the MRI findings in neurologically handicapped children who had suffered from neonatal hypoglycaemia and to evaluate the relationship between the neurological impairment and neonatal hypoglycaemia. Materials and methods. We retrospectively evaluated the MRI findings in eight full-term infants with neonatal symptomatic hypoglycaemia who later exhibited neurological handicap. The age at which the MRI scans were obtained ranged from 9 months to 8 years 10 months (mean 4 years 1 month, median 4 years). Results. The most striking findings were prolonged T1 weighting and ...

1999-01-01

74

A non-toxic ligand for voxel-based MRI analysis of plaques in AD transgenic mice  

UK PubMed Central (United Kingdom)

Amyloid plaques are a characteristic feature in Alzheimer’s disease (AD). A novel non-toxic contrast agent is presented, Gd-DTPA-K6Aβ1–30, which is homologous to Aβ,...Full Text Available

2008-06-01

75

Assessment of PET and MRI Polar Map using Gaussian Mixture Model  

International Nuclear Information System (INIS)

Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate methodological approach for automatic measurement of ...

2010-10-01

76

IMAGING DIAGNOSIS-SYNOVIAL MYXOMA OF LUMBAR VERTEBRAE ARTICULAR PROCESS JOINT  

British Library Electronic Table of Contents (United Kingdom)

Magnetic resonance (MR) imaging and histopathology were used to diagnose an articular process synovial myxoma in a dog. On MR images, the tumor was characterized by distortion of the left L1-L2 articular process, widening of the articular process joint, and the presence of a mass contiguous with the synovium of the articular process that displaced the spinal cord. The tumor was T2-hyperintense, T1-hypointense, relative to muscle, and had mild contrast enhancement. The MR features of articular process synovial myxoma may be distinct from other diseases of the articular process joint.

2011-01-01

77

Lacrimal gland masses on CT and MRI: a report of four cases; Raumforderungen der Traenendruese in CT und MRT am Beispiel von vier Faellen  

Energy Technology Data Exchange (ETDEWEB)

In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.) [Deutsch] In einem erweiterten Fallbericht wird ueber die vier ...

1995-11-01

78

Quantitative measurements of injections into porous media with contrast based MRI  

British Library Electronic Table of Contents (United Kingdom)

Porous flow occurs in a wide range of materials and applies to many commercially relevant applications such as oil recovery, chemical reactors and contaminant transport in soils. Typically, breakthrough and pressure curves of column floods are used in the laboratory characterization of these materials. These characterization methods lack the detail to easily and unambiguously resolve flow mechanisms with similar effects at the core scale that can dominate at the aquifer or oil field scale, as well as the effects of geometry that control the flow at interfaces as in a perforated well or the inlet of an improperly designed column. Non-invasive imaging techniques such as MRI have been shown to provide a far more detailed characterization of the properties of the solid matrix and flow, but usu...

2011-01-01

79

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle; CT und MRT erworbener Veraenderungen des Innenohrs und Kleinhirnbrueckenwinkels  

Energy Technology Data Exchange (ETDEWEB)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by ...

2003-03-01

80

Experimental study of lipiodol ultra-fluid. On its signal intensity in MR imaging  

Energy Technology Data Exchange (ETDEWEB)

Lipiodol Ultra-Fluid (Lipiodol) is widely applied in the transcatheter arterial embolization (TAE). We studied signal intensity, the T1 relaxation time and the T2 relaxation time of Lipiodol itself using Siemens Magnetom H15-2 T (1.5 Tesla) and Magnetom M10 (1.0 Tesla). Lipiodol showed higher signal intensity than saline solution on the T1-weighted images (short TR, short TE technique in spin echo method). On the T2-weighted images (long TR, long TE technique in spin echo method), Lipiodol showed lower signal intensity than saline solution. The T1 relaxation time of Lipiodol, measured at 1.0 T, was 201 msec and 218 msec at 1.5 T. The T2 relaxation time of Lipiodol, measured at 1.0 T, was 127 msec; and 167 msec at 1.5 T. The signal intensity of Lipiodol at 1.0 T was higher than the intensity at 1.5 T. Shorter T1 relaxation time of Lipiodol at 1.0 T is probably ...

1988-11-01

81

Magnetic resonance imaging in multiple sclerosis. Imagerie nouvelle par resonance magnetique nucleaire au cours de la sclerose en plaques  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the lesion(s). At the ...

1991-09-15

82

MRI in combined subacute degeneration of the spinal cord; MRT bei funikulaerer Myelose  

Energy Technology Data Exchange (ETDEWEB)

The MRI morphology in combined subacute degeneration has only rarely been reported. We describe two patients suffering from subacute combined degeneration of the spinal cord on the basis of a deficiency of vitamin B{sub 12}. In both patients characteristic hyperintense areas on T{sub 2}-weighted images in the posterior columns of the cervical and thoracic cord without contrast enhancement were demonstrated by MRI. (orig.) [Deutsch] Bisher liegen zur wenige Beschreibungen der MR-Morphologie bei funikulaerer Myelose vor. Wir beschreiben zwei Patienten mit den klinischen Zeichen einer funikulaeren Myelose auf der Basis eines Vitamin B{sub 12}-Mangels. Bei beiden konnten mit der MRT charakteristische Signalanhebungen im T{sub 2}-gewichteten Bild in den Hinterstraengen des zervikalen und thorakalen Rueckenmarks gezeigt werden. Eine Kontrastmittelaufnahme war nicht nachweisbar. (orig.)

1999-06-01

83

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE)  

International Nuclear Information System (INIS)

T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is ...

84

First experiences with application of gadolinium-DTPA in infants and small children under two years of age  

International Nuclear Information System (INIS)

The use of Gadolinium-DTPA as a paramagnetic contrast agent in MRI with adults and juveniles concerning brain and spinal cord pathology is well proven since years. In the FRG it is only introduced for children over two years of age. Therefore this report deales with the experience in four infants and small children under the age of two. They all were suffering from neurological tumors and got additional diagnostic information in three cases. Clinical side-effects like urticaria, vomiting or convulsions had not been observed nor had pathologic changes of the biochemical parameters been noticed. (orig./GDG).

85

Benign diseases of the mandible in MRI; Benigne Erkrankungen des Unterkiefers im MRT  

Energy Technology Data Exchange (ETDEWEB)

Diseases of the mandible affect the soft tissues aside from the osseous manifestation. This can be shown clearly and in great detail by magnetic resonance imaging (MRI). MRI is the gold standard in the diagnostic evaluation of any internal derangement of the temporomandibular joint. Dental MRI requires high resolution techniques and in some cases also intravenous administration of contrast material. These techniques allow delineation of the neurovascular bundle. In the past few years new indications were formulated, for example, the evaluation of the integrity of the inferior alveolar nerve in trauma and in radicular cysts. New quantitative methods now enable insights into the pathophysiology. The objective of this review is to communicate accepted indications for MRI of the mandible and to present innovative applications. (orig.) [German] Mandibulaere Erkrankungen beteiligen neben ...

2004-04-01

86

Unsolved problems in the diagnosis and surgical treatment of intramedullary tumors  

Energy Technology Data Exchange (ETDEWEB)

Problems and solutions in the diagnosis and operative treatment were clarified by retrospective evaluation of cases of intramedullary tumor in which MRI and surgery had been performed. The subjects were 16 patients (21-75 years old, mean age: 45 years) whose tumor was surgically removed between 1991 and 1998. MRI was performed preoperatively, and T1-weighted images, T2-weighted images, and enhanced images were obtained. Angiography was also performed in some cases. The histological diagnosis based on the MRI findings before surgery were compared with the pathological diagnosis after the operation. In 9/16 cases (56%), the preoperative histological diagnosis based on the MR images was the same as the pathological diagnosis after the operation. In 8 of the 11 cases (73%) whose images showed clear tumor margins and well shaped the tumor, the tumors were completely removed. The ...

2001-04-01

87

Radiologic findings of extraosseous Ewing's sarcoma  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. Margins were well defined in four out of the six patients. Four ...

2005-09-01

88

Ganglioneuromas in childhood: MRI and CT characteristics; Ganglioneurome im Kindesalter: CT- und MRT-Charakteristika  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled ...

2000-05-01

89

Observation and control of hepatic specimens with MRI and MRS; Beobachtung und Kontrolle von Fixiervorgaengen in Leberpraeparaten mittels MRT und MRS  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The purpose of this study was to observe the process of fixation in liver specimens non-invasively by means of magnetic resonance. The fixation process of several formaldehyde-containing solutions was monitored with MRI and MRS at two different temperatures. Materials and Methods: Liver specimens were conserved in aqueous fixative solutions containing formaldehyde concentrations of 0.7, 1.8, 4 and 7.2% and at different temperatures of 5 C and 20 C. MRI was performed with T1-, T2- and PD-weighted TSE sequences, a 2D FLASH-sequence with and without magnetization transfer, and a FISP 3D-sequence on a clinical 1.5 Tesla MR whole-body unit, and MRS with {sup 1}H-spectroscopic methods (STEAM-sequence) on a 3 Tesla MR whole-body unit. Results: The diffusion of formaldehyde into the tissue was best identified on PD- and T1-weighted images as a band under the liver surface with increasing thickness, ...

2004-04-01

90

Gd-25 DTPA-MAb, a potential NMR contrast agent for MRI in the xenografted nude mouse: preliminary studies  

Energy Technology Data Exchange (ETDEWEB)

Monoclonal antibodies (MAbs) 19-9 and 73-3 specific for human colon adenocarcinoma were labelled with a high number of gadolinium atoms. Twenty five DTPA were chelated per MAb, with only slight loss of immunoreactivity. The NMR contrast agent Gd-25 DTPA-MAb 19-9 or 73-3 ((Gd) 17 mumole/kg, (MAb) 60 microM) was injected into nude mice bearing human colon adenocarcinoma (SW948). Tumors were removed 24 hr after injection and T1 was measured in vitro. T1 relaxation time varied according to MAb specificity against tumour targets; T1 decreased 20% for MAb 19-9 and MAb 73-3 with SW948 tumor. Imaging was performed with this model. Very good contrast was obtained 24 hr after Gd-25 DTPA-MAb injection.

1988-01-01

91

MRI with SPIR sequences of optic nerve lesions; Utilita' delle sequenze 'Selective Partial Inversion Recover' (SPIR) nelle mallattie del nervo ottico  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the yield of SPIR sequences with fat suppression in the diagnosis of optic nerve lesions. T1 and T2 weighted fat suppressed SPIR imaging of the optic nerve improves anatomical definition, lesion detection and characterization in optic nerve conditions. [Italian] L'articolo analizza i vantaggi ricavabili dall'utilizzazione delle sequenze SPIR nella documentazione del decorso del nervo ottico e delle sue alterazioni nei pazienti con sospetto clinico e strumentale di malattia retrobulbare. L'utilizzo delle sequenze SPIR consente ottimale visualizzazione del nervo ottico e delle sue eventuali alterazioni senza gli artefatti che limitavano la qualita' delle immagini nelle prime sequenze RM con soppressione del segnale del grasso.

1999-04-01

92

Influence of contrast-enhanced CT and MRI with or without SPIO particles on therapy and therapy costs for patients with focal liver disease; Einfluss von biphasischer Spiral-CT, nativer und eisenoxidverstaerkter MRT auf Therapie und Therapiekosten bei Patienten mit fokalen Leberlaesionen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and ...

2000-03-01

93

Pituitary disease in childhood: utility of magnetic resonance; Patologia hipofisaria en la edad pediatrica: unidad de la resonance magnetica  

Energy Technology Data Exchange (ETDEWEB)

To assess the utility of magnetic resonance (MR) imaging in the study of pediatric patients with clinical suspicion of pituitary disease. We studied 18 patients aged 7 to 18 years.Fifteen had hormonal disturbances, two presented amenorrhea and 1 complained of headache, fever and symptoms of polyuria and polydipsia. All the patients were examined using a Siemens SP 42 1-Tesla MRI scanner. Sagittal and coronal T1-weighted spin-echo images were obtained; in addition T2-weighted spin-echo or fast spin-echo imaging was performed in ten cases and intravenous gadolinium was administered in nine. We found 9 patients with hypothalamic-pituitary dysgenesis, 2 with germinoma, 2 cases of pituitary hemosiderosis in patients with thalassemia, 2 cases of microadenoma, one abscess, one case of idiopathic central diabetes insipidus and one of Langerhans cell histiocytosis. MR enabled us to assess pituitary structural alterations in children ...

2000-07-01

94

Hyperoxia-induced acute lung injury using a pig model. Correlation between MR imaging and histologic results  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to correlate MR imaging findings with pathology in experimental hyperoxia-induced acute lung injury, which has similar pathology to diffuse alveolar damage (DAD). Seventeen Yorkshire pigs were studied. These animals were exposed to more than 80% oxygen for 24, 48, 72, and 96 hours in a sealed cage. The lungs were removed and inflated with air infused through the trachea, and then examined by both MRI and high-resolution CT (HRCT). T1-weighted spin-echo (T1WSE), T2-weighted fast (T2WFSE), and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences were performed. Severity in MR findings and signal-to-noise ratios (SNR) on MR images were well correlated with pathological scores. CT values were also correlated well with pathologic scores. Abnormal SNR values were obtained from a pathological score of 5, whereas abnormal CT values were ...

2001-06-01

95

Magnetic resonance imaging assessment of brain maturation in preterm neonates with punctate white matter lesions  

International Nuclear Information System (INIS)

Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weighted images and decreased signal on T2-weighted images with no evidence of cystic degeneration. A group of 22 preterm infants with PWML at term PMA (PWML group) were compared with 22 matched controls with a normal MR ...

2007-02-01

96

Digital atlas of fetal brain MRI  

International Nuclear Information System (INIS)

Fetal MRI can be performed in the second and third trimesters. During this time, the fetal brain undergoes profound structural changes. Interpretation of appropriate development might require comparison with normal age-based models. Consultation of a hard-copy atlas is limited by the inability to compare multiple ages simultaneously. To provide images of normal fetal brains from weeks 18 through 37 in a digital format that can be reviewed interactively. This will facilitate recognition of abnormal brain development. T2-W images for the atlas were obtained from fetal MR studies of normal brains scanned for other indications from 2005 to 2007. Images were oriented in standard axial, coronal and sagittal projections, with laterality established by situs. Gestational age was determined by last menstrual period, earliest US measurements and sonogram performed on the same day as the MR. The software program used for viewing the ...

2010-02-01

97

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity; Moderne bildgebende Methoden bei der Diagnostik von Tumoren des Oropharynx und der Mundhoehle  

Energy Technology Data Exchange (ETDEWEB)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in ...

1996-11-01

98

MRI in definition of bleeding source, lesion pattern and therapy in haemarthros of the knee; Die MRT beim Haemarthros des Kniegelenks: Bestimmung von Blutungsursachen, Verletzungsmustern und Therapie  

Energy Technology Data Exchange (ETDEWEB)

Patients with haemarthros of the knee were examined by MRI and arthroscopy to identify the bleeding source and to determine surgical or conservative therapy. A prospective study was performed on 120 patients who underwent MRI and arthroscopy, point lesions and bleeding sources were documented separately on a standardised form. Arthroscopy demonstrated a ruptured anterior cruciate ligament in 86%, meniscal tears in 55%, disruption of collateral ligaments in 17%, osteochondral lesions in 5% and tears of capsule or plicae in 13%. Disruption of cruciate ligaments caused haemorrhage in all but three cases. In contrast, only meniscal tears located very adjacent to the meniscal basement had bled. Those types of osteochondral lesions caused haemorrhage characterised on MRI by destruction of the subchondral plate and overlying cartilage. Severe lesions of the knee were diagnosed by MRI in ...

1996-09-01

100

FDTD ??? ??? 3T MRI? RF ??? ??  

KoreaScience (Korea)

Full Text Available

2000-09-01

105

Intracranial tuberculoma: MR imaging  

International Nuclear Information System (INIS)

MR studies of 6 patients with intracranial tuberculoma are reviewed. All patients also underwent CT scans which showed hypo- or isodense lesions with abnormal enhancement following contrast administration. MR showed lesions with prolongation of the T1 relaxation time in every case. On the T2-weighted sequences, the signal properties of the tuberculoma varied according to the stage of evolution of the lesion. Incipient tuberculomas appeared as scattered areas of hypointensity surrounded by edema. Mature tuberculomas were composed of a dark necrotic center surrounded by an isointense capsule which was, in turn, surrounded by edema. In one patient, the center of the lesion was hyperintense probably because of liquefaction and pus formation (tuberculous abscess). While both, CT and MR, were equally sensitive in visualizing the intracranial tuberculoma in every patient, MR was slightly superior in demonstrating the extent of the ...

1988-11-01

106

3D MRI of the colon: methods and first results of 5 patients; 3D-MRT des Kolons: Methodik und erste Ergebnisse  

Energy Technology Data Exchange (ETDEWEB)

Purpose: `Exoscopic` and endoscopic identification of colorectal pathologies via MRI. Methods: 5 patients (36-88 years), two normal and three with different colorectal pathologies (diverticular disease, polyps and carcinoma of the colon), were examined by MRI after colonoscopy. Subsequent to filling of the colon with a gadolinium-water mixture under MRI-monitoring, 3D-data sets of the colon were acquired in prone and supine positions over a 28 sec breathold interval. Subsequently multiplanar T{sub 1}-weighted 2D-sequences were acquired before and following i.v. administration of Gd-DTPA (0.1 mmol/kg BW). All imaging was performed in the coronal orientation. The 3D-data were interactively analysed based on various displays: Maximum intensity projection (MIP), surface shadowed display (SSD), multiplanar reconstruction (MPR), virtual colonoscopy (VC). Results: All of the colorectal pathologies could be interactively diagnosed ...

1997-09-01

107

S-matrix elements and covariant tachyon action in type 0 theory  

Energy Technology Data Exchange (ETDEWEB)

We evaluate the sphere level S-matrix element of two tachyons and two massless NS states, the S-matrix element of four tachyons, and the S-matrix element of two tachyons and two Ramond-Ramond vertex operators, in type 0 theory. We then find an expansion for theses amplitudes that their leading order terms correspond to a covariant tachyon action. To the order considered, there are no T4, T2(-bar T)2, T2H2, nor T2R tachyon couplings, whereas, the tachyon couplings FF-bar T and T2F2 are non-zero.

2005-01-17

108

Advanced MRI Methods for Assessment of Chronic Liver Disease  

UK PubMed Central (United Kingdom)

MRI plays an increasingly important role for assessment of patients with chronic liver disease. MRI has numerous advantages, including lack of ionizing radiation and the possibility of performing...Full Text Available

2009-07-01

109

MR imaging guidance and monitoring of focal thermotherapies. A review; Steuerung und Monitoring von fokalen Thermotherapien mit der Magnetresonanztomographie. Ein Ueberblick  

Energy Technology Data Exchange (ETDEWEB)

Minimally invasive thermotherapies for focal tissue destruction on the basis of laser-, microwave-, focused ultrasound-, or cryogeninduced changes of tissue temperature represent an alternative to surgical tissue ablation, particularly in the treatment of tumors. The thermotherapy modalities listed necessitate indirect guidance and monitoring, since they often do not lend themselves to immediate visual control. In the brain, in head and neck tumors, in the liver, and in the prostate, MRI reliably and accurately delineates both the positions of interstitial thermotherapy applicators and - in contrast-enhanced, T1-weighted images - the perfusion defects in tissue necrosis induced by thermotherapy. The transfer of results of in-vitro and in-vivo model studies to assess interstitial temperature and lesion development during thermotherapy to the actual treatment of patients, however, is still in an initial phase. Further development of both rapid ...

1998-03-01

110

Fast quantitative diffusion-tensor imaging of cerebral white matter from the neonatal period to adolescence  

International Nuclear Information System (INIS)

We investigated the isotropic diffusion coefficient (D') and fractional anisotropy (FA) in white matter (WM) during brain development, using an optimised diffusion-tensor imaging (DTI) method with whole brain coverage in a clinically acceptable time. We images 52 children with no evident neurological abnormality (30 boys, 22 girls aged 1 day-16 years) using high-angle DTI with optimised temporal gradient performance. D' and FA were calculated in 10 regions of interest in white matter. We saw that the age-related reduction in D' and increase in FA follow a mono- or biexponential model in white matter, probably depending on the compactness and myelination rate of the fibre tracts. In contrast to other areas, in which adult values were reached during the third year, there is a trend to continuous increase in FA in all deep white-matter areas, suggesting continuing maturation and organisation of deep tracts not detected on conventional MRI. (orig.)

2004-04-01

111

Efficacy of MR mammography (MRM) in providing preoperative locoregional information on breast cancer. Correlation between MRM and histological findings  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess the efficacy of MRM in providing preoperative locoregional information on patients with breast cancer. MRI was performed on 62 female breast cancer patients. A 1.5 T MR-system was used to acquire fat-suppressed T{sub 1}WI, T{sub 2}WI and dynamic-contrast-enhanced images with an SPGR pulse sequence. The extent of the cancer measured with MRM was confirmed histologically in all patients. The size obtained from MRM correlated well with the size obtained histologically, including intraductal spread of cancer (R: 0.853). As for shape, the round/oval type evident from MRM correlated more accurately (R: 0.934) than the ill-defined type associated with a linear and/or clumped enhanced area (R:0.744). The difference between the size obtained from MRM and the size obtained histologically, including IDS, was less than 15 mm in the majority of patients (93.5%). MRM accurately reveals the extent of cancer, including ...

2002-07-01

113

Dura thickening adjacent to intracranial tumors on MRI. Histologically correlation; Duraverdickung am Rand intrakranieller, duranaher Raumforderungen in der MRT. Histologische Korrelation  

Energy Technology Data Exchange (ETDEWEB)

Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T{sub 2}-weighted spin echo (SE) images as well as T{sub 1}-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 meningiomas and 15 of 19 metastases ...

1997-11-01

114

MRI of liposarcomas. Observations on 28 liposarcomas; Magnetresonanztomographie der Liposarkome. Beobachtungen an 28 Liposarkomen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Liposarcoma is the most common soft tissue sarcoma in adults. The purpose of the study was to correlate MR imaging features with the four ICD subclasses. Methods: 28 patients with liposarcoma were examined preoperatively on a 1.0 T MRI system, using spin echo sequences, gradient echo imaging and STIR sequences. In all patients, classification of the liposarcomas was made by histologic diagnosis (ICD-10-M-classification). Results: Well differentiated liposarcomas (9 patients) showed a number of MRI features consistent with lipoma (well defined mass high signal intensity (SI) on T{sub 1} images, low signal on T{sub 2} images, no or only little signal increase of tumour tissue after contrast material application, no necrosis). Not well differentiated liposarcomas (myxoid 14 patients, pleomorphic three patients, round cell two patients) revealed the largest part of the mass to be of low SI on T{sub 1}-weighted images. ...

1996-08-01

115

A comparison of hepatic in vitro metabolism of T-2 toxin in rats, pigs, chickens, and carp  

British Library Electronic Table of Contents (United Kingdom)

T-2 toxin, a highly toxic member of the type-A trichothecenes, is produced by various Fusarium moulds that can potentially affect human health. It is strongly cytotoxic for human hematopoietic progenitors. Alimentary toxic aleukia (ATA), a disease typically associated with human, is primarily induced by T-2 toxin. A comparison of the metabolism of T-2 toxin incubated with hepatocytes of rats, piglets, chickens, and the hepatic subcellular fractions (microsomes and cytosol) of piglets, chickens, rats, and carp (common carp and grass carp) was carried out. The activities of the recombinant pig CYP3A29 on the transformation of T-2 and HT-2 toxins were preliminary studied. Metabolites were identified by novel LC/MS-IT-TOF. Qualitative similarities and differences across the species were observ...

2011-01-01

127

T-2 mycotoxin inhibits mitochondrial protein synthesis  

Energy Technology Data Exchange (ETDEWEB)

The authors investigated the effect of T-2 toxin on rat liver mitochondrial protein synthesis. Isolated rat liver mitochondria were supplemented with an S-100 supernatant from rat liver and an external ATP-generating system. An in-vitro assay employing cycloheximide, and inhibitor of cytoplasmic protein synthesis, and chloramphenicol, and inhibitor of mitochondrial protein synthesis, to distinguish mitochondrial protein synthesis from the cytoplasmic process. Amino acid incorporation into mitochondria was dependent on the concentration of mitochondria and was inhibited by chloramphenicol. The rate of uptake of tritium leucine into mitochondrial protein was unaffected by the addition of T-2 toxin and was not a rate-limiting step in incorporation. However, 0.02 micrograms/ml of T-2 toxin decreased the rate of protein synthesis inhibition correlated with the amount ...

1988-01-01

128

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while ...

1988-01-01

129

Diagnosis of peanut inhalation by MRI  

International Nuclear Information System (INIS)

We describe a 16-month-old boy presenting with stridor and fever. The chest X-ray suggested inhalation of a foreign body but here was no history of this. A high spot a T_1-weighted chest MRI was due to a peanut which was seen to have moved from the right main bronchus to the left inferior bronchus, between the two MRI studies. MRI can provide information on position and size of the peanut, the conditons of the surrounding tissues and may be also useful in treatment. We consider MRI to be a valuable new method for the diagnosis of peanut inhalation. (orig./GDG).

1992-01-01

130

Multiphasic helical CT of hepatocellular carcinoma. Evaluation after chemo embolization  

International Nuclear Information System (INIS)

The main purpose of this work is to report the personal experience with addition of contrast-enhanced multiphase helical CT to unenhanced CT (Lipiodol CT) in the evaluation of patients with hepatocellular carcinoma treated with chemoembolization and to analyze the present role of oily agent CT. It has been retrospectively reviewed the examinations of 42 consecutive patients submitted to globla chemoembolization over a 2-year period. CT was performed 18-30 days after the treatment. The Lipiodol CT study was carried out with volume acquisitions. It has been considered as nodules all well-defined areas with dense oily agent uptake; uptake itself was classified as: 0=absent, I=lower tha 10% of the tumor volume; II=lower than 50%, III=50%, IV=homogeneous. Contrast-enhanced helical CT was performed with the 2-phase technique in 28 patients and with the 3-phase technique in 14; it has been considered as nodules all well-defined and relatively ...

2000-06-01

131

Aortic non communicating dissections. A study with helical CT  

International Nuclear Information System (INIS)

The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density ...

2000-09-01

132

Le leucodistrofie: aspetti clinici e quadri con Tomografia Computerizzata e con Risonanza Magnetica  

International Nuclear Information System (INIS)

Leukodystrophies are inherited white matter diseases due to abnormalities occurring in myelin synthesis and/or maintenance. The most common types of these rare childhood conditions are represented by adrenoleukodystrophy, metachromatic leukodystrophy, Canavan's, Alexander's, Krabbe's, and Pelizaeus-Merzbacher's diseases. Most of them are lethal during childhood, with the exception of the adrenoleukodystrophy-adrenomyeloneuropathy complex, which sometimes, during its early phases, may be cured with a dietary therapy. The aims of this paper are: 1) the description of inheritance factors, pathogenesis, pathological and clinical findings of each of the most frequent childhood leukodystrophies; 2) the description of the most common patterns of these conditions on CT and MR imaging; 3) the evaluation of the diagnostic capabilities of these two imaging techniques and the comparison of their results. Finally, some of the therapies suggested for the mild forms of these conditions are discussed. ...

1991-01-01

133

Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed T{sub 1}-weighted spin echo sequences before ...

2002-05-01

134

A T-2 translational research perspective on interventions to improve post-fracture osteoporosis care  

British Library Electronic Table of Contents (United Kingdom)

The objectives of this paper are to: quickly outline the extent of the care gap in osteoporosis; define T-2 (knowledge) translation and its relationship to quality improvement; discuss the barriers to best practice in osteoporosis care after a fracture; convey the importance of rigor in design and evaluation of translational interventions by drawing upon examples from the broader literature; describe in some detail a series of post-fracture intervention trials conducted in Alberta, Canada; and make some conclusions specifically about osteoporosis interventions and more generally about T-2 translational research.

2011-01-01

135

Spin-density-wave transition and #mu#SR in the heavy-fermion Ce(Ru, T)_2Si_2, T = Rh, Pd  

International Nuclear Information System (INIS)

... 900526-11-8 277 p. MATERIALS SCIENCE antiferromagnetic materials cerium

1999-02-28

136

Numerical field calculations considering the human subject for engineering and safety assurance in MRI  

UK PubMed Central (United Kingdom)

Numerical calculations of static, switched, and radiofrequency (RF) electromagnetic (EM) fields considering the geometry and EM properties of the human body are used increasingly in MRI to explain...Full Text Available

2009-11-01

137

MRI features of epidural extramedullary hematopoiesis  

Energy Technology Data Exchange (ETDEWEB)

A case of {beta}-thalassemia intermedia with spinal cord compression due to extramedullary hematopoiesis, which was successfully treated by blood transfusion, is presented. Emphasis was made on the MRI appearance of extramedullary hematopoiesis on different pulse sequences. The theories that aimed to explain the involvement of the epidural space by extramedullary hematopoiesis are discussed.

2000-07-01

138

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

139

EXPONENTIAL TENSORS: A FRAMEWORK FOR EFFICIENT HIGHER-ORDER DT-MRI COMPUTATIONS  

UK PubMed Central (United Kingdom)

In Diffusion Tensor Magnetic Resonance Image (DT-MRI) processing a 2nd order tensor has been commonly used to approximate the diffusivity function at each lattice...Full Text Available

2007-05-15

140

Analysis of the Development of the Nasal Septum according to Age and Gender Using MRI  

UK PubMed Central (United Kingdom)

ObjectivesThis study was designed to evaluate the normal development of the nasal septum in Koreans using sagittal MRI for the valuable clinical information on septal procedures.MethodsTwo...Full Text Available

2008-03-01

141

Adaptive Thresholding for Improving Sensitivity in Single-Trial Simultaneous EEG/fMRI  

UK PubMed Central (United Kingdom)

A common approach used to fuse simultaneously recorded EEG and fMRI is to correlate trial-by-trial variability in the EEG, or variability of components derived therefrom, with the blood oxygenation...Full Text Available

142

Clinical magnetic resonance imaging with nuclear medicine correlation  

Energy Technology Data Exchange (ETDEWEB)

The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.

1985-08-01

143

Practical MRI atlas of neonatal brain development  

International Nuclear Information System (INIS)

This book is an anatomical reference for cranial magnetic resonance imaging (MRI) studies in neonates and infants. It contains 122 clear, sharp MRI scans and drawings showing changes in the normal appearance of the brain and skull during development. Sections of the atlas depict the major processes of maturation: brain myelination, development of the corpus callosum, development of the cranial bone marrow, and iron deposition in the brain. High-quality scans illustrate how these changes appear on magnetic resonance images during various stages of development.

144

MRI of the foetal brain  

International Nuclear Information System (INIS)

Ultrasound examinations for foetal brain abnormalities have been a part of the routine antenatal screening programme in the UK for many years. In utero brain magnetic resonance imaging (MRI) is now being used increasingly successfully to clarify abnormal ultrasound findings, often resulting in a change of diagnosis or treatment plan. Interpretation requires an understanding of foetal brain development, malformations and acquired diseases. In this paper we will outline the technique of foetal MRI, relevant aspects of brain development and provide illustrated examples of foetal brain pathology.

2007-04-01

145

Comparative Study of SVM Methods Combined with Voxel Selection for Object Category Classification on fMRI Data  

UK PubMed Central (United Kingdom)

BackgroundSupport vector machine (SVM) has been widely used as accurate and reliable method to decipher brain patterns from functional MRI (fMRI) data. Previous studies have not...Full Text Available

146

Renal artery stenosis after radiotherapy for Ewing's sarcoma  

International Nuclear Information System (INIS)

Background: the fact that therapeutic irradiation can induce significant stenosis in the arteries of the head, neck, and chest, as welt as in the aorta and the iliac arteries, is familiar in daily practice and well documented in the literature. By contrast, radiation-induced renal artery stenosis seems to be a less widely known complication. Patients and methods: the sudden onset of medically refractory arterial hypertension and coma in a 27-year-old man is reported, who had been treated at age 20 with chemotherapy and radiotherapy for Ewing's sarcoma in the lumbar region. This treatment had been performed at the hospital of Sion, Switzerland in 2001. Also, the relevant literature from 1965 to 2007 is reviewed to underscore various aspects of this problem and to demonstrate the clinical relevance of renal artery stenosis as a potential long-term sequela of radiotherapy. Conclusion: radiation-induced renal artery stenosis has only rarely been described in the ...

2008-09-01

147

Comparison of Stereotactic Radiosurgery and Whole Brain Radiotherapy in Patients with Four or More Brain Metastases  

International Nuclear Information System (INIS)

This study was a retrospective evaluation of the efficacy of stereotactic radiosurgery (SRS) in patients with >4 metastases to the brain. Materials and Methods: Between January 2004 and December 2006, 68 patients with ?4 multiple brain metastases were included and reviewed retrospectively. Twenty-nine patients received SRS and 39 patients received whole brain radiotherapy (WBRT). Patients with small cell lung cancers and melanomas were excluded. The primary lesions were non-small cell lung cancer (69.0%) and breast cancer (13.8%) in the SRS group and non-small cell lung cancer (64.1%), breast cancer (15.4%), colorectal cancer (12.8%), esophageal cancer (5.1%) in the WBRT group. SRS involved gamma-knife radiosurgery and delivered 10?20 Gy (median, 16 Gy) in a single fraction with a 50% marginal dose. WBRT was delivered daily in 3 Gy fractions, for a total of 30 Gy. After completion of treatment, a follow-up brain MRI or a contrast-enhanced ...

2009-09-01

148

Non cardiopatic and cardiopatic beta thalassaemic patients: quantitative and qualitative cardiac iron deposition evaluation with MRI; Pazienti {beta} talassemici non cardiopatici e cardiopatici: valutazione quantitativa e qualitativa del deposito di ferro cardiaco con RM  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Cardiomyopathy is one of the major complications of {beta} thalassaemia major as a result of transfusion iron overload. The aim of our study is to evaluate with MR if there is any difference of iron deposition signal intensity (SI) or distribution between non-cardiopatic and cardiopatic thalassaemic patients in order to establish if there is a relationship between cardiopathy and iron deposition. Materials and methods: We studied 20 patients affected by {beta} thalassaemia major, of whom 10 cardiopatic and 10 non-cardiopatic, and 10 healthy volunteers as control group. Serum ferritin and left ventricular ejection fraction were calculated in thalassaemic patients. All patients were examinated using a 1.5 MR unit with ECG-gated GE cine-MR T2*-weighted, SE T1-weighted and GE T2*-weighted sequences. In all cases, using an adequate ROI, the myocardial and skeletal muscle signal intensity (SI), the ...

2005-02-01

149

The role of MRI in the diagnosis of recurrent/persistent carpal tunnel syndrome: A radiological and intra-operative correlation  

British Library Electronic Table of Contents (United Kingdom)

MRI (Magnetic resonance imaging) has been widely used in the diagnosis of primary carpal tunnel syndrome (CTS). However, it has had limited clinical application in diagnosing persistent or recurrent CTS. We aimed to investigate the efficacy of this imaging modality in patients who had previously undergone open carpal tunnel release without relief of symptoms, and assess the correlation of MRI with intra-operative findings upon re-exploration. MRI studies were performed on 17 wrists (16 patients) presenting with recurrent/persistent symptoms and signs of CTS in whom repeat nerve conduction studies were also performed. Surgical re-exploration was undertaken on 16 wrists in which a 100% correlation was noted between MRI and intra-operative findings of an incompletely released or re-grown tran...

2011-01-01

150

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac ...

2009-03-01

151

New procedures. Comprehensive staging of lung cancer by MRI  

International Nuclear Information System (INIS)

Lung cancer staging according to the TNM system is based on morphological assessment of the primary cancer, lymph nodes and metastases. All aspects of this important oncological classification are measurable with MRI. Pulmonary nodules can be detected at the clinically relevant size of 4-5 mm in diameter. The extent of mediastinal, hilar and supraclavicular lymph node affection can be assessed at the same time. The predominant metastatic spread to the adrenal glands and spine can be detected in coronal orientation during dedicated MRI of the lungs. Search focused whole body MRI completes the staging. Various additional MR imaging techniques provide further functional and clinically relevant information during a single examination. In the oncological context the most important techniques are imaging of perfusion and tumor motion. Functional MRI of the lungs complements the pure staging and improves ...

2010-08-01

152

Magnetic resonance imaging of chronic aortic dissection  

International Nuclear Information System (INIS)

17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).

153

MRT for operation planning in anal atresias  

International Nuclear Information System (INIS)

We evaluated in this study the value of preoperative examinations of anal atresia with an optimised MRI strategie. 13 patients with anorectal anomalies, most of them younger than one year, underwent an MRI examination of the pelvis. 10 of these patients were operated afterwards. Compared with the situs shown by the operation the results of the MRI examination were very exact in all cases in respect of the level of atresia and the development of the striateed muscle complex. Fistulas could be completely described in most cases. MRI demonstrated additional lesions in some patients which were of great importance for planning the further treatment of the patients. As a consequence MRI can give valid information on anal atresia for planning the operative treatment. (orig.).

154

Sequential changes in the femoral head after intracapsular fracture of the femoral neck. MRI findings  

International Nuclear Information System (INIS)

Authors obtained T1-weighted MRI images of the femoral head after fracture of the femoral neck and classified the signals into four patterns to investigate the sequential changes of the femoral head. The T1-weighted MRI images obtained initially after femoral neck fracture showed a normal pattern in 10 of the 15 hip joints studied. MRI images obtained subsequently still showed the normal signal pattern in eight of the 10 hip joints which had shown the normal pattern in the first MRI, while two of the 10 joints subsequently showed a band pattern. The joint with the homogeneous pattern in the first MRI subsequently showed a band pattern. Of the three joints with an inhomogeneous pattern in the first MRI, two joints showed a subsequent band pattern, and the other a normal pattern. The joints which showed a band pattern continued to show a similar band pattern. ...

1998-07-01

155

Pre-operative MRI of anorectal anomalies in the newborn period  

Energy Technology Data Exchange (ETDEWEB)

Nine infants (six boys, three girls) with anorectal anomalies were examined in the immediate newborn period, prior to corrective surgery, with MRI. Three high, one intermediate and five low anomalies were found at MRI - one patient with a `low` lesion was subsequently found at surgery 2 months later to have a high anorectal anomaly. This infant had passed meconium per urethram soon after the MRI study, prompting the need for a protective colostomy and stressing the importance of a thorough clinical examination of babies with anorectal malformations. The MRI results and findings at surgery were in agreement in all other patients (n=8). Hydronephrosis was evident in two and renal agenesis in one patient. Sacrococcygeal hypoplasia was found in two and two hemivertebrae in one infant. No spinal cord lesion was identified. One fistula was evident on MRI but four were later found at ...

1995-11-01

156

MRI of congenital heart disease in childhood  

International Nuclear Information System (INIS)

MRI provides a non-invasive diagnostic tool complementing echocardiography on one hand, and showing advantages over echocardiography, on the other hand, especially after corrective procedures. The multiple different MRI sequences need to be adapted to examinations of children and patients with congenital heart disease (CHD), and can be used to detect morphologic changes, blood-flow in the heart and thoracic vessels and diastolic or systolic function of myocardium. Several factors determine the success of the examination of a complex congenital heart disease or a postoperative situs. Pediatric radiologists and radiologists experienced in congenital heart diseases have to work in close cooperation. Echocardiography should be performed before MRI. The results of prior examinations and the clinical history of the patients, including possible palliative or reconstructive operations, must be available before ...

2004-02-01

157

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences  

International Nuclear Information System (INIS)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and ...

158

SPIO-enhanced MR angiography for the detection of venous thrombosis in an animal model; SPIO-unterstuetzte MR-Angiographie zur Detektion venoeser Thromben im Tiermodell  

Energy Technology Data Exchange (ETDEWEB)

Purpose: An animal model is used to investigate whether MR angiography combined with super-paramagnetic particles of iron oxide (SPIO) is suitable for detecting thromboses. Methods: 42 rats in groups of 7 each were examined on days 1, 3, 5, 7, 9 and 11, respectively, after mechanical/chemical thrombus induction in a 1.5 Tesla magnet with a FISP sequence (TR/TE/FA 50 ms/6 ms/40 ). Imaging was performed before and up to 90 minutes after intravenous injection of 30 {mu}mol FE/kg BW of the experimental SPIO (hydrodynamic diameter, 34{+-}17 nm LLS; R1 and R2 relaxivity at 0.47 T, 31 and 57 L/(mmol*s)). MIP reconstructions of MR angiographies were submitted to consensus assessment by two examiners using histology as the gold standard. Results: The image quality of MIP reconstructions was rated as good in 38 of 42 cases. With regard to thrombotic vessel occlusion, MR angiography coincided with histology in 17 of 42 cases and differed in 25, lumen narrowing being overestimated by ...

1999-03-01

159

MR imaging of regional late brain development  

International Nuclear Information System (INIS)

This paper reports, to complement current knowledge on brain development, late regional brain maturation assessed with quantitative MR imaging. Axial and coronal head spin-echo (SE) images were obtained in 60 healthy individuals aged 5--56 years, with a double-echo, flow compensated imaging sequence obtained with a 1.5-T Magnetom spectroscopy and imaging system. T2-weighted images were calculated from the intensity differences in SE images at echo times (TEs) of 15 and 90 msec (TR = 2.5 second). The mean T2 values were determined at 16 sites in each cerebral hemisphere. T2 values of the six frontal subcortical white matter (FSCWM) sites and of the internal capsule (IC) were evaluated. Mean T2 values in the IC decreased until age 10 years, whereas this decrease continued in the FSCWM past age 15 years before reaching a ...

160

New pulse sequence for simultaneous T1, T2, and RHO determination in whole-body proton MR imaging  

International Nuclear Information System (INIS)

A newly developed method to support tissue characterization in routine MR imaging is presented. It represents a compromise between the practical requirements of clinical routine (short measurement time, multisection imaging) and the necessary accuracy of the relaxation parameter evaluation. The sequence employed is a modification of the PHAPS technique and works with two excitation pulses. It allows the simultaneous acquisition of all measurement data for the subsequent T1, T2, and rho evaluations. T1 is determined with a specially designed computation formula based on four signal ratios. A multiexponential T2 analysis is performed with use of 28 echoes. From these parameters, relative proton density can be computed.

161

Effects of Sleep Apnea Severity on Glycemic Control in Patients with Type 2 Diabetes Prior to Continuous Positive Airway Presssure Treatment  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background: Obstructive sleep apnea (OSA), a highly prevalent condition, is independently associated with increased risks of developing type 2 diabetes mellitus (T2D) and metabolic syndrome. It is unclear, however, if the severity of OSA has any impact on glycemic control among patients with T2D. We therefore aimed to determine the independent association between OSA severity and glycosylated hemoglobin (HbA1c) in patients with T2D. Methods: This was an observational cross-sectional study of 52 consecutive patients attending the diabetes obesity clinic between January 2008 to February 2010 with risk factors for sleep apnea and who underwent polysomnography study. Clinical, demographic, and lifestyle data were recorded using a questionnaire. Results: Prevalence of OSA in this clini...

2011-01-01

162

Determination of left ventricular ejection fraction and wall thickness in magnetic resonance imaging at 1.0 Tesla in comparison to echocardiography and biplanar ventriculography  

International Nuclear Information System (INIS)

We compared the values of the myocardial thickness and the left ventricle diameters measured with MRI and echocardiography. The ejection fraction was compared in MRI and ventriculography. 34 patients with different heart dysfunctions were examined with MRI (FISP 2D sequence). 26 of them were also studied by echocardiography and 20 by biplane cine-ventriculography. The enddiastolic thicknesses of the left ventricular postero-lateral wall and of the septum interventriculare were measured on short axis images. An ellipsoidal modell was used for volume calculation and ejection fraction. Correlation of MRI values of thickness and ejection fraction with echocardiographi and angiographi showed r>0,8. As known for 1.56 T Imagers, the myocardial thickness in MRI was underestimated compared to echocardiography (1.4 mm#+-#1.7). The ejection fraction was underevaluated compared to ...

163

An availability of brain magnetic resonance imaging (MRI) in the early diagnosis of latent hepatic encephalopathy  

Energy Technology Data Exchange (ETDEWEB)

Brain MRI was carried out in patients with chronic liver diseases. No abnormal findings were recognized in patients with chronic viral hepatitis, while 59.2% of cirrhotics showed a symmetrically strong signal in basal ganglia on T1 weighted image in MRI. This finding significantly related with lowered Fischer`s ratio of serum amino acid, increased levels of serum phenylalanine, tyrosine and hyaluronic acid, prolonged prothrombin time and decreased platelet counts in the peripheral blood. Overt hepatic encephalopathy was observed in 6 of 34 patients with the strong signal in MRI during follow-up period, while none of patients without that finding developed hepatic encephalopathy. These results have indicated that the strong signal in basal ganglia on MRI appears in cirrhotic patients with severe liver dysfunction, and it is an useful index in the early diagnosis of latent hepatic encephalopathy. An ...

1996-03-01

164

Nasal cavity volume measured in normal persons by MRI  

Energy Technology Data Exchange (ETDEWEB)

Nasal cavity volume was studied in 69 healthy volunteers (from 8 to 23 years old) by MRI. The right and left nasal cavity areas were measured on horizontal images displayed directly on the MRI console. The nasal cavity volume was obtained by integrated volume calculation. The nasal cavity volume was positively correlated with age, body height and weight up to age 16. The body height and weight reached a plateau at 16 years, but the nasal cavity volume continued to increase. There was no significant difference in the volumes of the right and left cavities. (author).

1993-10-01

165

Nasal cavity volume measured in normal persons by MRI  

International Nuclear Information System (INIS)

Nasal cavity volume was studied in 69 healthy volunteers (from 8 to 23 years old) by MRI. The right and left nasal cavity areas were measured on horizontal images displayed directly on the MRI console. The nasal cavity volume was obtained by integrated volume calculation. The nasal cavity volume was positively correlated with age, body height and weight up to age 16. The body height and weight reached a plateau at 16 years, but the nasal cavity volume continued to increase. There was no significant difference in the volumes of the right and left cavities. (author).

166

MRI survival guide  

International Nuclear Information System (INIS)

The book is a German translation of an American textbook with the original title ''MRI Survival Guide'' and is intended to serve as an introductory guide for beginners or a reference book for quick information. Readers will find information on the fundamentals of the technology and methodology of MRI as well as all details of relevance to practice in a precise and easy-to-grasp arrangement, covering all anatomic areas of interest, illustrations and descriptions of characteristic signs of pathologic processes, high-quality and unusually large-sized diagnostic pictures, a modern didactic concept for quick orientation, including surveys, tables, and reproductions for visualisation of contents. (orig./CB)

167

Sodium bicarbonate-based hydration prevents contrast-induced nephropathy: a meta-analysis  

UK PubMed Central (United Kingdom)

BackgroundContrast-induced nephropathy is the leading cause of in-hospital acute renal failure. This side effect of contrast agents leads to increased morbidity, mortality, and health...Full Text Available

168
169

Spatiotemporal Evolution of the fMRI Response to Ultrashort Stimuli  

UK PubMed Central (United Kingdom)

The specificity of the hemodynamic response function (HRF) is determined spatially by the vascular architecture and temporally by the evolution of hemodynamic changes. The stimulus duration...Full Text Available

2011-01-26

170

Sacral haemangioma as a cause of coccydynia  

International Nuclear Information System (INIS)

We report a 55-year-old woman with coccydynia due to a sacral mass. The histological diagnosis was haemangioma. The MRI findings and the unusual location of this lesion are discussed. (orig.)

1998-08-01

171

Magnetic resonance imaging in human lymphodemas  

International Nuclear Information System (INIS)

The MRI's of 16 patients with either primary or secondary lymphatic disorders are evluated and the findings are compared to those from lymphangioscintigraphy or surgery. (author).

1989-09-02

172

MRI in the diagnosis of non-compacted ventricular Myocardium (NCVM) compared to echocardiography  

International Nuclear Information System (INIS)

Purpose: To report the detection of con-compacted ventricular myocardium (NVCM) with MRI compared to echocardiography in 8 patients. Material and methods: Non-compaction of the ventricular myocardium is a congenital disorder characterized by an altered structure of the myocardial wall resulting from an intrauterine arrest in endomyocardial embryogenesis. The morphological findings consist of a prominent meshwork of multiple myocardial trabeculations and deep intertrabecular recesses, communicating with the left ventricular cavity. 8 consecutive patients (mean age 7.3 years) with clinical and echocardiographic signs of NCVM were examined by MRI (1.5 T, Vision, Siemens) in short axis and 2- and 4-chamber views, using T_1-weighted TSE and Cine-GRE in 6 patients and true FISP sequences in 2 patients. MRI and echocardiography were evaluated for visibility, signs of NCVM and involvement of myocardial wall segments. Thickness was ...

2003-09-01

173

Large (≥2cm) non-hypervascular nodules depicted on MRI in the cirrhotic liver: fate and implications  

British Library Electronic Table of Contents (United Kingdom)

Aim To determine the fate and clinical implication of large (?2cm), non-hypervascular nodules depicted on magnetic resonance imaging (MRI) in the cirrhotic liver. Materials and methods In 21 patients with cirrhosis (14 hepatitis B, two ethanol abuse, four cryptogenic, one Wilson's disease), 25 large (?2cm in the longest dimension) non-hypervascular nodules were identified on dynamic MRI. The implications for diagnosis of the initial size, contour, and signal characteristics on MRI in addition to patients' age and cause of cirrhosis were assessed in our analysis. Results Twelve (75%) out of 16 lesions were malignant or potentially-malignant from 14 hepatitis B patients, while seven (78%) of the nine lesions from other patients were benign (p=0.016). The mean age of the patients who ha...

2008-01-01

174

In vivo MRI analysis of an inflammatory injury in the developing brain  

UK PubMed Central (United Kingdom)

Cerebral periventricular white matter injury stands as a leading cause of cognitive, behavioral and motor impairment in preterm infants. There is epidemiological and histopathological evidence...Full Text Available

2010-07-01

175

Identification and staging of bladder carcinoma  

International Nuclear Information System (INIS)

The purpose of the present study was to compare the effectiveness of MRI, CT and radioimmunoscintigraphy in the staging and detection of bladder cancers in 28 patients. We distinguish two groups: Group I included the tumour stages CIS-T_3_A and the second group the deep infiltrative tumours T_3_B-T_4. MRI was slightly superior to CT in respect of tumour staging (75% correct results as compared to 63%). No understaging occurred with MRI, whereas in 22% of the cases the stage of the tumour was underestimated using CT diagnostics. Overstaging occurred in 25% of the MRI and 15% of the CT-diagnostics, respectively. RIS cannot distinguish the tumour groups, and hence this method is useful only for the detection of the primary tumour and metastases. In 77% of cases the tumour was detected and in 15% the tumour could be safely excluded. (orig.).

176

Functional MRI-compatible laparoscopic surgery training simulator  

British Library Electronic Table of Contents (United Kingdom)

Abstract During the past few years, laparoscopy has become the gold standard for some surgical procedures and its applications continue to expand. Because of multiple factors such as loss of tactile perception, two-dimensional visualization of the three-dimensional surgical field, and demanding bimanual hand-eye coordination, special training is required to achieve proficiency with laparoscopy. In this study, as the first step toward evidence-based development of strategies to improve the quality of laparoscopy training from brain activity and behavior relationships, a laparoscopy training simulator was developed for use in functional MRI. Experiments confirmed the functional MRI compatibility of the device. Representative behavioral and functional MRI results for two subjects showed the f...

2011-01-01

177

Final Report of OT-45, PVM-8, and RVTO Weather ...  

Science.gov (United States)

... A second hydrometeor sampler (MRI Model 1220 ... The cloud particle probe normally installed in ... to the northeast showed no significant movement. ...

1975-07-01

178

Temporal Stability of Urinary and Plasma Biomarkers of Tobacco Smoke Exposure among Cigarette Smokers  

UK PubMed Central (United Kingdom)

Intraindividual variability of measurements of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), nicotine, cotinine, and r-1,t-2,3,c-4-tetrahydroxy-1,2,3,4-tetrahydrophenanthrene...Full Text Available

2010-06-01

179

Molecular dynamic study of different regions of Angelin Pedra (Himenolobium paetrum) wood by low field NMR  

International Nuclear Information System (INIS)

Angelin Pedra is a specie found in the north of Mato Grosso State in Brazil, where an expressive volume of waste of this wood is produced. An alternative to recycle this waste is to produce wood plastic composites. However, structural and chemical investigations are fundamental to generate information for this use. In the present work, low field NMR was used to determine the spin-lattice and spin-spin relaxation times with objective to investigate the molecular dynamic behavior of the alburnu and cerne regions of Angelin Pedra aiming at a potential use of this waste wood in polymeric composites. The results of the proton spin-lattice relaxation time (T1H) and the proton spin-spin relaxation time (T2H) showed at least three different mobility domains for both regions. Among the values, one was very flexible and other was rigid. Knowing that wood is a polymer composite basically constituted by cellulose, hemicellulose and lignin can attribute the ...

2005-11-06

180

Large-scale association analysis of TNF/LTA gene region polymorphisms in type 2 diabetes  

UK PubMed Central (United Kingdom)

BackgroundThe TNF/LTA locus has been a long-standing T2D candidate gene. Several studies have examined association of TNF/LTA...Full Text Available

181

Insulin and Glucagon Regulate Pancreatic ?-Cell Proliferation  

UK PubMed Central (United Kingdom)

Type 2 diabetes mellitus (T2DM) results from insulin resistance and β-cell dysfunction, in the setting of hyperglucagonemia. Glucagon is a 29 amino acid peptide hormone, which is secreted from...Full Text Available

182

Increased SRF transcriptional activity in human and mouse skeletal muscle is a signature of insulin resistance  

UK PubMed Central (United Kingdom)

Insulin resistance in skeletal muscle is a key phenotype associated with type 2 diabetes (T2D) for which the molecular mediators remain unclear. We therefore conducted an expression analysis of human...Full Text Available

2011-03-01

183

Head and Neck Sentinel Lymph Node Biopsy: Current State of the Art  

UK PubMed Central (United Kingdom)

Sentinel node biopsy is an alternative to elective neck dissection for the management of T1/T2 oral and oro-pharyngeal squamous cell carcinomas and is also finding application to head and neck cancer...Full Text Available

184

Experimental Differential Light-Scattering Correction to the Circular Dichroism of Bacteriophage T2  

UK PubMed Central (United Kingdom)

Experimental techniques are presented that can be used to assay and correct for differential light scattering effects in circular dichroism spectra of biological macrostructures. The assay is based...Full Text Available

1973-01-01

185

Magnetic resonance imaging of the urogenital diaphragma in comparison with conventional histomorphological findings (the controversy about the deep transverse muscle of perineum); Kernspintomographische Untersuchungen des Diaphragma urogenitale im Vergleich mit korrespondierenden histomorphologischen Befunden (der Streit um den Misculus transversus perinei profundus)  

Energy Technology Data Exchange (ETDEWEB)

The transversus perinei profundus muscle is a well known structure in found anatomical textbook. Fibres of this muscle are believed to form the so-called external urethral sphincter (musculus sphincter urethrae). Recently histomorphologic investigations have shown that there is no muscular connection between the musculus sphincter urethrae (external sphincter) and the muscle system of the pelvic floor. Furthermore, the external sphincter was found to be divided into parts: The transversely striated part (musculus sphincter urethrae transversostriatus) and the smooth part (musculus sphincter urethrae glaber). Similar to histomorphologic investigations, contrast-enhanced MR imaging has shown the musculus sphincter urethrae to be surrounded by fatty and connective tissue only. Neither in MRI nor in anatomical slices can any connection between the urethral sphincter and the muscle system of the pelvic floor be found. Thus, on the basis of the ...

1997-01-01

186

Metastatic Ewing's sarcoma to the skull: CNS involvement excluded by MRI  

International Nuclear Information System (INIS)

A case of metastatic Ewing's sarcoma to the skull is presented, demonstrating the superiority of magnetic resonance imaging over other imaging modalities to exclude CNS involvement. Precise delineation of different tumor components in extradural location contained in an intact dural rim together with compressed cortex showing no signs of tumorous involvement constituted an MRI appearance allowing us to exclude tumor outgrowth into the brain. (orig.).

187

MRI and 1H MRS of The Breast: Presence of a Choline Peak as Malignancy Marker is Related to k21 Value of the Tumor in Patients with Invasive Ductal Carcinoma  

UK PubMed Central (United Kingdom)

To assess which specific morphologic features, enhancement patterns, or pharmacokinetic parameters on breast Magnetic Resonance Imaging (MRI) could predict a false-negative outcome of Proton...Full Text Available

2008-01-01

188

Intrasphenoid cephalocele: MRI in two cases  

Energy Technology Data Exchange (ETDEWEB)

The intrasphenoid form of basal cephalocele is uncommon. We describe the clinical, CT and MRI findings in two cases presenting in middle age with persistent cerebrospinal fluid rhinorrhoea. Emphasis is placed upon the imaging findings which aid in discrimination of intrasphenoidal cephalocele from more common causes of a sphenoid sinus mass. (orig.)

1999-07-01

189

Implant detectibility of intervertebral disc spacers in post fusion MRI: evaluation of the MRI scan quality by using a scoring system - an in vitro study  

International Nuclear Information System (INIS)

Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium and cobalt chromium alloys and carbon fiber-reinforced polymers. Implant-related susceptibility artifacts can decrease the quality of MRI scans. The aim of this cadaveric study was to demonstrate the extent that implant-related MRI artifacting affects the postfusion differentiation of determined regions of interest (ROIs). In six cadaveric porcine spines, we evaluated the postimplantation MRI scans of a titanium, cobalt-chromium and carbon spacer that differed in shape and surface qualities. A spacer made of human cortical bone was used as a control. A defined evaluation unit was divided into ROIs to characterize the spinal canal as well as the intervertebral disc space. Considering 15 different MRI sequences read independently by an interobserver-validated team of specialists the artifact-affected image ...

2007-02-01

190

Cystic lesions of the seminal vesicles. Demonstration by MRI. Zystische Raumforderungen der Samenblasen. Darstellung mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Between October 1990 and March 1991, 8 patients with cystic lesions in the region of the posterior bladder wall, the seminal vesicles and the prostate were examined by MRI. In all cases there was accurate characterisation of the lesion and of its anatomy. In 3 patients with abnormalities in the retrovesical space there was very good agreement with the operative findings. 4 patients were treated conservatively. In these patients there was good agreement with the findings on cystoscopy, CT and sonography. (orig.).

1992-07-01

191

Soft tissue manifestations of early rheumatic disease. Imaging with MRI  

International Nuclear Information System (INIS)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). Only dactylitis was ...

2006-08-01

192

MRI, CT, sonography and thallium-technetium subtraction scintigraphy for the detection of parathyroid disease: a four-year experience  

International Nuclear Information System (INIS)

Sonography, subtraction scintigraphy, computed tomography and MRI were compared in 100 patients who had surgery 105 times for hyperparathyroidism (HPT). Surgical and pathological data were available for all operations. A total of 105 MR, 77 CT, 84 sonograms and 70 subtraction scintigrams were performed. The ability of the imaging modalities, individually and in combination, to detect HPT, histology, size, concomitant thyroid disease and location of the diseased glands has been evaluated. For primary HPT, sensitivity ranged from 68% for MRI to 40% for scintigraphy but was much lower for tertiary HPT with all modalities. The ability to identify diseased glands was strongly size dependent for all methods. If patients had had previous neck surgery, the most sensitive methods were MRI and scintigraphy and this also held true for patients with concomitant thyroid disease and ectopically located glands. The findings presented ...

196

Dialysis and contrast media  

Energy Technology Data Exchange (ETDEWEB)

In a previous survey we revealed uncertainty among responders about (a) whether or not to perform hemodialysis in patients with severely reduced renal function who had received contrast medium; and (b) when to perform hemodialysis in patients on regular treatment with hemodialysis or continuous ambulatory dialysis who received contrast medium. Therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and to issue guidelines. The committee performed a Medline search. Based on this, a report and guidelines were prepared. The report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy. Hemodialysis and peritoneal dialysis safely remove both iodinated and gadolinium-based contrast media. The effectiveness of hemodialysis depends on many factors including blood and dialysate flow rate, permeability of ...

2002-12-01

197

Total skin electron beam therapy followed by adjuvant psoralen/ultraviolet-a light in the management of patients with T1 and T2 cutaneous T-cell lymphoma (mycosis fungoides)  

International Nuclear Information System (INIS)

Purpose: Patients with mycosis fungoides [cutaneous T-cell lymphoma (CTCL)] may benefit from adjuvant therapy after completing total skin electron beam therapy (TSEBT). We report the results for (T1(T2)) CTCL patients treated with adjuvant oral psoralen plus ultraviolet light (PUVA) with respect to overall survival (OS), disease-free survival (DFS), salvage of recurrence, and toxicity. Methods and Materials: Between 1974 and 1993, TSEBT was administered to a total of 213 patients with CTCL. Records were reviewed retrospectively, and a total of 114 patients were identified as having T1 or T2 disease. Radiotherapy was provided via a 6-MeV linac to a total of 36 Gy, 1 Gy/day, 4 days/week, for 9 weeks. Beginning in 1988, patients were offered adjuvant PUVA within 2 months of completing TSEBT. This was started at 0.5-2 J/m"2, 1-2 treatments/week, with a taper over 3-6 months. Therapy then continued once per ...

1997-07-15

198

Severity of iron deficiency anemia and its relationship to growth and morbidity  

Energy Technology Data Exchange (ETDEWEB)

The relationships between severity of iron deficiency anemia, response to iron treatment, respiratory and gastrointestinal illness and weight changes were assessed before (T1) and after (T2) iron therapy. Seventy-five pre-school children from rural Guatemala received daily oral iron (ferrous sulfate 5 mg/kg/day) for eleven weeks, and were classified into one of three groups: (1) severe iron deficient (Hgb < 9.25 g/dl at T1 and > 1g/dl Hgb response (T2-T1) to Fe Rx; (2) moderately iron deficient (Hgb 9.25 g/dl to 11.5 g/dl and T2-T1 > 1g/dl); (3) normal controls (Hgb > 11.5 g/dl and T2-T1 < 1g/dl). When both severely and moderately anemic children were pooled together, there was a statistical significant difference between the number of days ill with gastrointestinal symptoms of these children and those in ...

1986-03-01

199

Diffusion-and T2-weighted MR imaging of lipiodol induced cerebral infarcts in cat: early findings in the first 3 hours  

Energy Technology Data Exchange (ETDEWEB)

This study was designed to evaluate early parenchymal changes of acute cerebral is chemia/infarct by using T2-weighted, diffusion-weighted, and calculated apparent diffusion coefficient(ADC) MR imaging. The brain MR images were successfully obtained 30, 60, 90, 120, 150 and 180 minutes after intraarterial administration of Lipiodol (0.4-0.6ml) into the common carotid artery in 10 of 11 cats (91%). T2-and diffusion-weighted images and ADC were analyzed and compared with histopathologic findings. High signal intensity on T2-weighted and diffusion-weighted images was found in one cerebral hemisphere 30 minutes after Lipiodol injection, which tended to increase with time until 3 hours. Subcortical white matter showed higher signal intensity than cortical gray matter since 30 minutes after embolization. ADC images showed decreased signal intensity in the embolized ...

1997-06-01

200

Appearance of normal brain maturation on 1.5-T MR images  

International Nuclear Information System (INIS)

To investigate the pattern of normal white-matter maturation as demonstrated by high-field-strength MR imaging, 82 normal infants were examined using a 1.5-T unit with spin-echo T1-weighted and T2-weighted pulse sequences. The infants ranged in age from 4 days to 2 years. The scans were assessed for qualitative changes of white matter relative to gray matter and correlated with the patient's age in 14 anatomic areas of the brain. The MR images showed that changes of brain maturation occur in an orderly manner, commencing in the brain stem and progressing to the cerebellum and the cerebrum. Changes from brain myelination were seen earlier on T1-weighted images than on T2-weighted images, possibly because of T1 shortening by the components of the developing myelin sheaths. The later changes on the T2-weighted images correlated best with the development of ...

201

Steady particulate flows in a horizontal rotating cylinder  

Energy Technology Data Exchange (ETDEWEB)

Results of discrete element method (DEM) simulation and magnetic resonance imaging (MRI) experiments are compared for monodisperse granular materials flowing in a half-filled horizontal rotating cylinder. Because opacity is not a problem for MRI, a long cylinder with an aspect ratio {approximately}7 was used and the flow in a thin transverse slice near the center was studied. The particles were mustard seeds and the ratio of cylinder diameter to particle diameter was approximately 50. The parameters compared were dynamic angle of repose, velocity field in a plane perpendicular to the cylinder axis, and velocity fluctuations at rotation rates up to 30 rpm. The agreement between DEM and MRI was good when the friction coefficient and nonsphericity were adjusted in the simulation for the best fit. {copyright} {ital 1998 American Institute of Physics.}

1998-06-01

202

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented.

1985-08-01

203

Inflammatory spine disease as a cause of back pain  

International Nuclear Information System (INIS)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-#alpha# antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-#alpha# antagonists is based on clinical and laboratory criteria, and signs of inflammation in MRI. ...

2006-06-01

204

Early spondyloarthropathy: scintigraphic, biological, and clinical findings in MRI-positive patients  

British Library Electronic Table of Contents (United Kingdom)

There are no specific diagnostic tests or a gold standard method for measuring disease activity and outcome in spondyloarthropathies (SpA). Many different methods have been developed to assess the signs and symptoms in SpA. The aim of this study was to evaluate the value of scintigraphy, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and Bath Ankilosing Spondylitis Disease Activity Index (BASDAI) in the evaluation of disease activity in early axial SpA diagnosed with magnetic resonance imaging (MRI). Thirty early MRI-positive axial SpA patients (23 males, 7 females) with a median age of 35 (18?55) years and a median duration of inflammatory low back pain of 24 (8?60) months were included in the study. In the patients with sacroiliitis, the sensitivity, specificity, and pos...

2008-01-01

205

Early diagnosis of skeletal disorders in childhood and adolescence by MRI; Fruehdiagnose orthopaedischer Erkrankungen des Kindes- und Jugendalters mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

The early diagnosis of such disorders is of major importance because, in most cases, severe consequences can only be averted by early treatment. The value of magnetic resonance imaging (MRI) in many orthopaedic and traumatological conditions is generally accepted. The value of MRI in this particular field is illustrated by typical case reports on common clinical problems [Deutsch] Der Fruehdiagnose von Erkrankungen des Kindes- und Jugendalters kommt grosse Bedeutung zu, da oftmals nur durch eine daraus resultierende Fruehbehandlung schwerwiegende Folgen vermieden werden koennen. Die Kernspintomographie (Magnetresonanztomographie=MRT) ist in zahlreichen orthopaedischen-traumatologischen Fragestellungen bereits etabliert. An ausgewaehlten Fallbeispielen haeufiger klinischer Problemstellungen soll in der vorliegenden Arbeit der Stellenwert der MRT dargestellt werden. (orig.)

1998-09-18

206

A novel method for quantifying scanner instability in fMRI  

British Library Electronic Table of Contents (United Kingdom)

Abstract A method was developed to quantify the effect of scanner instability on functional MRI data by comparing the instability noise to endogenous noise present when scanning a human. The instability noise was computed from agar phantom data collected with two flip angles, allowing for a separation of the instability from the background noise. This method was used on human data collected at four 3 T scanners, allowing the physiological noise level to be extracted from the data. In a -well-operating- scanner, the instability noise is generally less than 10% of physiological noise in white matter and only about 2% of physiological noise in cortex. This indicates that instability in a well-operating scanner adds very little noise to functional MRI results. This new method allows researcher...

2011-01-01

207

MRT versus CT in the diagnosis of pneumonia. Evaluation of a T_2-weighted utrafast turbo-spin-echo sequence (UTSE)  

International Nuclear Information System (INIS)

Purpose: To evaluate a T_2-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T_2-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR_e_f_f/T_E/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT ...

1999-05-01

208

First hint for CP violation in neutrino oscillations from upcoming superbeam and reactor experiments  

CERN Document Server

We compare the physics potential of the upcoming neutrino oscillation experiments Daya Bay, Double Chooz, NOvA, RENO, and T2K based on their anticipated nominal luminosities and schedules. After discussing the sensitivity to theta_{13} and the leading atmospheric parameters, we demonstrate that leptonic CP violation will hardly be measurable without upgrades of the T2K and NOvA proton drivers, even if theta_{13} is large. In the presence of the proton drivers, the fast track to hints for CP violation requires communication between the T2K and NOvA collaborations in terms of a mutual synchronization of their neutrino-antineutrino run plans. Even in that case, upgrades will only discover CP violation in a relatively small part of the parameter space at the 3 sigma confidence level, while 90% confidence level hints will most likely be obtained. Therefore, we ...

2009-01-01

209

Scoring of brain maturation in developmentally handicapped children with high-field MR imaging  

International Nuclear Information System (INIS)

A four-stage scoring system for brain maturation was established with MR imaging. First, gyration and myelination were analyzed in 50 anamnestically normal children (32-240 weeks postconceptional age). Subsequently 60 patients (same age range) with birth asphyxia, seizures, or developmental delays were evaluated analogously. T1- and T2-weighted images (500/30 and 3,000/120 [repetition time msec/echo time msec]) were obtained with a 2.35-T magnet in all children. Whereas gyration abnormalities were seen in some patients, all handicapped children presented with delayed myelination. In conclusion, prospective staging of brain development (gyration and myelination) is possible and is best obtained with T2-weighted images.

210

Paroxysmal nocturnal hemoglobinuria: a case report of MR, CT findings  

Energy Technology Data Exchange (ETDEWEB)

Paroxysmal nocturnal hemoglobinuria (PNH) is a rare, acquired disease involving multiple hematopoietic cell lines. Characteristics of PNH are intrinsic hemolytic anemia, iron deficiency anemia and venous thrombosis. We report a case of PNH with characterostoc MR and CT findings. The signal intensity of renal cortex was lower than that of medulla on both T1-and T2-weighted MR imaging. On T2 weighted MR images, the liver showed very low signal intensity but the signal intensity of the spleen was normal. On precontrast CT the attenuation of renal cortex was higher than that of renal medulla and the attenuation of liver was higher than that of the spleen. These findings of MR imaging and CT were the result from the deposition of hemosiderin in the cells of proximal convoluted tubules and transfusional hemosiderosis of liver.

1995-10-15

211

Applicator reconstruction and applicator shifts in 3D MR-based PDR brachytherapy of cervical cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...

2009-01-01

212

The Influence of Moderate Hypercapnia on Neural Activity in the Anesthetized Nonhuman Primate  

UK PubMed Central (United Kingdom)

Hypercapnia is often used as vasodilatory challenge in clinical applications and basic research. In functional magnetic resonance imaging (fMRI), elevated CO2 is applied to derive stimulus-induced...Full Text Available

2008-11-01

213

Segmentation of Myocardial Boundaries in Tagged Cardiac MRI Using Active Contours: A Gradient-Based Approach Integrating Texture Analysis  

UK PubMed Central (United Kingdom)

The noninvasive assessment of cardiac function is of first importance for the diagnosis of cardiovascular diseases. Among all medical scanners only a few enables radiologists to evaluate the local cardiac...Full Text Available

2009-01-01

214

Safety Implications of High-Field MRI: Actuation of Endogenous Magnetic Iron Oxides in the Human Body  

UK PubMed Central (United Kingdom)

BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available

215

Normal and abnormal water diffusion in the brain  

International Nuclear Information System (INIS)

Diffusion magnetic resonance imaging (MRI) has become an important tool in the radiologic diagnosis of diseases of the brain as it measures molecular motion of water that characterizes the microstructure of tissues. Its most important clinical use to date is the early detection of cerebral ischemia by revealing the ischemic injury shortly after vessel occlusion and simultaneously providing therapy-relevant information on the tissue at risk. Furthermore, diffusion MRI is diagnostically promising in other diseases of the brain and is thus increasingly becoming part of routine clinical protocols in the diagnosis of tumors, inflammation, trauma, demyelination, dysmyelination and neurodegeneration. Although abnormalities of diffusion are generally not pathognomonic, diffusion MRI affords information about tissue changes for specific disorders that complements information obtained with standard MR techniques and frequently shows ...

2003-10-01

216

Non-white noise in fMRI: does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been ...

2005-01-01

217

Non-white noise in fMRI: Does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been ...

2006-01-01

218

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

219

Mapping strain exerted on blood vessel walls using deuterium double-quantum-filtered MRI  

UK PubMed Central (United Kingdom)

A technique is described for displaying distinct tissue layers of large blood vessel walls as well as measuring their mechanical strain. The technique is based on deuterium double-quantum-filtered (DQF)...Full Text Available

1998-04-14

220

Magnetic resonance imaging findings in 46 elbows with a radial head fracture  

UK PubMed Central (United Kingdom)

Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available

2010-06-01

221

MRI classification of interspinous ligament degeneration of the lumbar spine: intraobserver and interobserver reliability and the frequency of disagreement  

UK PubMed Central (United Kingdom)

Posterior spinal ligament pathology is becoming increasingly recognized as a significant cause of low back pain. Despite the growing clinical importance of interspinous ligament degeneration in low...Full Text Available

2010-10-01

222

MRI Findings of Pericardial Fat Necrosis: Case Report  

UK PubMed Central (United Kingdom)

Pericardial fat necrosis is an infrequent cause of acute chest pain and this can mimic acute myocardial infarction and acute pericarditis. We describe here a patient with the magnetic resonance imaging...Full Text Available

2011-05-01

223

MR imaging of the lateral collateral ligaments after ankle sprain; Aussenbandrupturen des Sprunggelenkes - Darstellung mit der MRT vor und nach funktioneller Therapie  

Energy Technology Data Exchange (ETDEWEB)

35 patients with ankle sprain were examined by MRI and stress radiographs. 13 were operated afterwards, 22 patients underwent a functional conservative therapy and were examined by MRI and stress radiographs and second time after three months. MRI reports were correct in 12 of 13 operated cases. After conservative therapy we did not find any disrupted ankle ligament. MRI showed intact ligaments thickened by scar. (orig./MG) [Deutsch] 35 Patienten mit klinischem Verdacht auf Aussenbandruptur wurden mit der MRT untersucht. 13 Patienten wurden operiert, 22 konzervativ therapiert. Letztere wurden nach drei Monaten erneut mit MRT und gehaltenen Aufnahmen untersucht. Die MRT-Befunde stimmten in 12 von 13 Faellen mit den operativ erhobenen Befunden ueberein. Nach dreimonatiger konzervativer Therapie waren alle 22 Sprunggelenke stabil. Die rupturierten Baender stellten sich verdickt und durchgaengig dar. ...

1995-09-01

224

Interictal Functional Connectivity of Human Epileptic Networks Assessed by Intracerebral EEG and BOLD Signal Fluctuations  

UK PubMed Central (United Kingdom)

In this study, we aimed to demonstrate whether spontaneous fluctuations in the blood oxygen level dependent (BOLD) signal derived from resting state functional magnetic resonance imaging (fMRI) reflect...Full Text Available

225

Incidental brain lesions on MRI in the depressive elderly  

Energy Technology Data Exchange (ETDEWEB)

The study was designed to determine the correlation between parenchymal lesions on MRI and depression. Thirty patients with depression satisfying the following criteria were selected: (1) 60 years or over at the time of MRI scanning, (2) no evidence of cerebrovascular disorder or dementia, and (3) no evidence of neurological findings such as extremity palsy. Seventy six patients with no history of psychiatric visits to a clinic served as controls. There was no significant difference in risk factors for cerebrovascular disorders, such as hypertension, diabetes mellitus, and ischemic heart disease, between the depressive group and the control group. MRI manifestations were semiquantitatively scored according to the periventricular hyperintensity (PVH), white matter hyperintensity (WMH), and pons hyperintensity (PH). All of the PVH score, WMH score, and cerebral enlargement index correlated with age. Although there was no ...

1994-07-01

226

Imaging of membranous dysmenorrhea  

Energy Technology Data Exchange (ETDEWEB)

Membranous dysmenorrhea is an unusual clinical entity. It is characterized by the expulsion of huge fragments of endometrium during the menses, favored by hormonal abnormality or drug intake. This report describes a case with clinical, US, and MRI findings before the expulsion. Differential diagnoses are discussed. (orig.)

2001-06-01

227

Functional Impact of White Matter Hyperintensities in Cognitively Normal Elderly  

UK PubMed Central (United Kingdom)

ObjectiveTo investigate the impact white matter hyperintensities (WMH) detected on MRI have on motor dysfunction and cognitive impairment in non-demented elderly...Full Text Available

2010-11-01

228

Focal structural changes and cognitive dysfunction in juvenile myoclonic epilepsy  

UK PubMed Central (United Kingdom)

Objective:The aim of this study was to determine if there were focal cortical abnormalities in juvenile myoclonic epilepsy (JME) using neuropsychological investigations and MRI.Methods:Twenty-eight...Full Text Available

2011-01-04

229

Evaluation of fetal brain development by magnetic resonance imaging. Subependymal germinal matrix layer and cerebral ventricle  

International Nuclear Information System (INIS)

Three dimensional data of brain from the formalin-fixed fetuses were collected without isolation, by the 4.7 tesla super high magnetic field MRI and the developmental process of the cerebral parenchyma was studied by 3D images. Subjects were 13 fetal brain and MRI was performed using 3D-steady-state free precession sequence. The isolated brain is very soft and fragile and is deformed by its weight at the imaging. However 3D-MRI can be obtained without isolation, and the deformation is remarkably small. The subependymal germinal matrix layer did not be observed in 7 weeks-old fetus, appeared at 9 weeks-old and increased gradually. Then it rapidly reduced from 28 weeks-old. The volume calculated, from 3D-MRI, increased rapidly from 9 weeks-old to 23 weeks-old, and reached the maximum (2.346 mm"3) at 23 weeks-old. The relation between fetal ages and volume of cerebral ventricle also showed similar pattern. ...

1999-10-01

230

Evaluation of femoral head perfusion by dynamic MRI  

International Nuclear Information System (INIS)

The purpose of this study was to evaluate the usefulness of dynamic MRI for femoral head perfusion. Objects were 64 femoral heads of 44 normal cases (20-95 years old), 10 cases (33-90 y) of femoral neck fracture and 8 cases (61-86 y) using steroid due to articular rheumatism, nephrosis and other diseases. Siemens 1.0 T Magneton Impact with body array coil was used for dynamic MRI by the fast low-angle shot 2D method for every 17 sec interval. Gd-DTPA was injected intravenously. ROI was defined in the center of femur head and of trochanter to monitor their values for the dynamic curve. Evaluation was done on the ratio of enhancement ratio (ER) in the head/trochanter and on the curve in both heads. In normal cases, the head ER was significantly lower in >60 years old cases. There was neither significant correlation between their head/trochanter ER ratios nor significant difference between their dynamic curves. In fracture cases, there were ...

1998-05-01

231

Delineation of the Middle Longitudinal Fascicle in Humans: A Quantitative, In Vivo, DT-MRI Study  

UK PubMed Central (United Kingdom)

Experimental and imaging studies in monkeys have outlined various long association fiber bundles within the temporoparietal region. In the present study the trajectory of the middle longitudinal fascicle...Full Text Available

2009-04-01

232

Convection-enhanced delivery of maghemite nanoparticles: Increased efficacy and MRI monitoring  

UK PubMed Central (United Kingdom)

Convection-enhanced drug delivery (CED) is a novel approach to delivering drugs into brain tissue. Drugs are delivered continuously via a catheter, enabling large volume distributions of high drug concentrations...Full Text Available

2008-04-01

233

Comprehensive Approach to Arthroscopic Rotator Cuff Repair: Options and Techniques  

Medline Plus

... and at that point she had already failed physical therapy, which someone else had prescribed, and so ... MRI, we may try a brief course of physical therapy to see if they feel better, but ...

234

Combining fMRI with EEG and MEG in order to relate patterns of brain activity to cognition  

UK PubMed Central (United Kingdom)

The common factor that underlies several types of functional brain imaging is the electric current of masses of dendrites. The prodigious demands for the energy that is required to drive the...Full Text Available

2009-07-01

235

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

236

Catheter Ablation for Paroxysmal Atrial Fibrillation  

Medline Plus

... catheter ablation for paroxysmal atrial fibrillation procedure utilizing 3-D mapping and rotational intracardiac echocardiography. This program is ... of the MRI scan and then there's the 3-D image, which is generated from the pixels chosen ...

237

Bone stress injury of the ankle in professional ballet dancers seen on MRI  

UK PubMed Central (United Kingdom)

BackgroundBallet Dancers have been shown to have a relatively high incidence of stress fractures of the foot and ankle. It was our objective to examine MR imaging patterns of bone...Full Text Available

238

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system  

International Nuclear Information System (INIS)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)

2001-09-01

239

Assessing and Compensating for Zero-lag Correlation Effects in Time-lagged Granger Causality Analysis of fMRI  

UK PubMed Central (United Kingdom)

Effective connectivity in brain networks can be studied using Granger causality analysis which is based on temporal precedence, while functional connectivity is usually derived using zero-lag...Full Text Available

2010-06-01

240

A wide spectrum of clinical and brain MRI findings in patients with SLC19A3 mutations  

UK PubMed Central (United Kingdom)

BackgroundSLC19A3 (solute carrier family 19, member 3) is a thiamin transporter with 12 transmembrane domains. Homozygous or compound heterozygous mutations in SLC19A3 cause...Full Text Available

241

To study the role of dynamic magnetic resonance imaging in assessing the femoral head vascularity in intracapsular femoral neck fractures  

Energy Technology Data Exchange (ETDEWEB)

Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy ...

2010-09-15

242

To study the role of dynamic magnetic resonance imaging in assessing the femoral head vascularity in intracapsular femoral neck fractures  

International Nuclear Information System (INIS)

Intracapsular femoral neck fractures remain unsolved fractures even after improvement in techniques of diagnosis and internal fixation. Individuals who sustain displaced femoral neck fractures are at high risk of developing avascular necrosis and non-union. Although several methods for predicting the viability of femoral head have been reported, they are not effective or widely used because of unreliability, potential complications and technical difficulties. Dynamic MRI was introduced in the recent past as a simple, non-invasive technique to predict the femoral head viability after the femoral neck fractures. In this study role of dynamic MRI was studied in 30 patients with 31 intracapsular femoral neck fractures. Fractures were divided in to three types according to dynamic curve patterns on MRI evaluation and were followed up for 6 months to 2 years to observe the final outcome. Sensitivity, Specificity and the Accuracy ...

2010-09-01

243

Childhood neuroborreliosis: clinicoradiological correlation  

Energy Technology Data Exchange (ETDEWEB)

We report the cranial CT and MRI findings in three children with Lyme disease (neuroborreliosis). The neuroimaging findings in children have been rarely reported. We found cranial MRI far superior to cranial CT. Ring-enhancing lesions have been described in acute disseminating encephalomyelitis and multiple sclerosis but not in neuroborreliosis. Although other infectious and inflammatory diseases cannot be excluded, Lyme disease should be included in the differential diagnosis and put forward as being the most likely diagnosis in the appropriate clinical setting. Gadopentetate dimeglumine is helpful in assessing the response to antibiotic treatment. (orig.)

1995-10-01

244

Bilateral lipoma arborescens of the bicipitoradial bursa  

International Nuclear Information System (INIS)

A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)

2002-11-01

245

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

246

On the internal perceptual structure of distinctive features: The [voice] contrast  

UK PubMed Central (United Kingdom)

Several fixed classification experiments test the hypothesis that F1, f0, and closure voicing covary between intervocalic stops contrasting...Full Text Available

2008-01-01

247

High Contrast Near-infrared Polarized Reflectance Images of Demineralization on Tooth Buccal and Occlusal Surfaces at ?=1310-nm  

UK PubMed Central (United Kingdom)

Background and Objectives:Sound enamel manifests peak transparency in the near-IR (NIR) at 1310-nm, therefore the near-IR is ideally suited for high contrast imaging...Full Text Available

2009-03-01

248

Analysis of the Sulfate-Reducing Bacterial and Methanogenic Archaeal Populations in Contrasting Antarctic Sediments  

UK PubMed Central (United Kingdom)

The distribution and activity of communities of sulfate-reducing bacteria (SRB) and methanogenic archaea in two contrasting Antarctic sediments were investigated. Methanogenesis dominated in freshwater...Full Text Available

2003-06-01

249

Quantification of cardiac function with multislice spiral CT using retrospective EKG-gating: comparison with MRI  

International Nuclear Information System (INIS)

Purpose: To quantify left ventricular function derived from retrospectively ECG-gated multislice spiral CT (MSCT) data sets in comparison to MRI. Materials and Methods: In 16 patients (14 males, 2 females, mean age 56.8 #+-# 11.5 years), retrospectively ECG-gated MSCT angiography of the coronary arteries and breath-hold steady state free precession cine MRI were performed. From MSCT data-sets, 20 axial image series were reconstructed every 5% of the RR interval. Multiplanar images were reformatted in the short axis orientation from axial images. End-systolic and end-diastolic images were selected. From these images end-systolic volume (ESV), end-diastolic volume (EDV) and stroke volume (SV) as well as the ejection fraction (EF) and myocardial mass (MM) were determined using the Simpson's method and compared with MRI. Furthermore, image quality was assessed for both imaging modalities using a four point grading scale. ...

2003-01-01

250

MRI-based N-staging in esophageal cancer  

International Nuclear Information System (INIS)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. ...

2002-10-01

251

Hypercapnic normalization of BOLD fMRI: comparison across field strengths and pulse sequences.  

DEFF Research Database (Denmark)

The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response by a global hypercapnia-induced BOLD signal. To demonstrate the effectiveness of the BOLD normalization approach, gradient-echo BOLD fMRI at 1.5, 4, and 7 T and spin-echo BOLD fMRI at 4 T were performed in human subjects. For neural stimulation, subjects performed sequential finger movements at 2 ...

2004-01-01

252

Dynamic enhanced MRI of the subacromial bursa: correlation with arthroscopic and histological findings  

Energy Technology Data Exchange (ETDEWEB)

Objective: To assess dynamic MRI with Gd-DTPA enhancement for evaluating inflammatory changes in the subacromial bursa. Design and patients: We detected the signal intensity changes in dynamic MRI of the subacromial bursa, and confirmed these macroscopically by arthroscopy and histologically. The signal intensity was measured using built-in software, and the enhancement ratio (E ratio) was calculated from dynamic MR images. In addition, as a parameter of the rate of the increase in the signal intensity from 0 to 80 s, the mean increase per second in the E ratio was obtained as the coefficient of enhancement (CE). The correlation was studied of the E ratio and CE with the arthroscopic findings (redness, villous formation, thickening and adhesion), and of the E ratio and CE with the histological findings (capillary proliferation, papillary hyperplasia, fibrosis and inflammatory cell infiltration) of the subacromial bursa. Of patients with ...

2003-09-01

253

Diffusion and perfusion MR imaging in stroke; MR-Diffusion und -Perfusion beim Schlaganfall  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) in stroke makes it possible to visualize the initial infarct in cases of acute cerebral ischemia. Perfusion MRI serves to determine which tissues are additionally at risk of infarction due to persistent hypoperfusion. MRI also allows those examiners with limited experience to reliably confirm an infarct. The most important differential diagnosis of cerebral ischemia, intracerebral hemorrhage, can likewise be recognized with certainty using MRI. Although diffusion and perfusion MRI only demonstrate the pathophysiology of cerebral ischemia approximately, the method is suited for identifying those patients who would profit from reperfusion therapy. Whether MRI is also appropriate as an aid to reaching a prognosis on the risk of secondary hemorrhage has not yet been resolved. (orig.) [German] Die Schlaganfall-MRT ermoeglicht es, bei ...

2005-05-01

254

Genetic Applications in Avian Conservation  

Science.gov (United States)

... structure along an elevational gradient in Hawaiian honeycreepers reveals contrasting evolutionary responses to avian malaria. BMC Evolutionary Biology 8: ... ...

255

Differential diagnosis by CT units with contrast enhancement  

Energy Technology Data Exchange (ETDEWEB)

Variation of CT units, in organs, before and after using contrast enhancing medium was reviewed and personal experience was presented. In the normal brain CT units was little changed by contrast enhancement (CE), whereas remarkable change was observed at lesions. No difference of CT units was observed between the normal liver and hepatomas. The normal kidney had higher CE effect than hypernephromas suggesting an increase of the sensitivity. CE was not found in cysts or necrosis. The changes of CT units in the cases of cerebral diseases are tabled with various contrast medium and scanners.

1981-04-01

257

Addition of methyl cellulose enema to double-contrast barium imaging of sigmoid diverticulosis  

Energy Technology Data Exchange (ETDEWEB)

Double-contrast barium enema has a reduced sensitivity in patients with severe sigmoid diverticulosis. Therefore a carboxy methyl cellulose enema was employed after the conventional double-contrast examination in 15 patients with sigmoid diverticulosis. A significant increase in lumen diameter and a superior removal of barium residue from the diverticulas facilitated the interpretation of the sigmoid loops. Conclusion: The addition of methyl cellulose enema to double-contrast barium imaging improves diagnostic imaging in diverticulosis by expanding the lumen and emptying the diverticulas. (orig.).

1997-01-01

258

AM: An Artificial Intelligence Approach to Discovery in ...  

Science.gov (United States)

... For example, contrast solving the Missionaries and Cannibals problem with the more ill-defined reasoning which led to inventing it. ...

1976-07-01

259

A bright field scanning transmission electron microscope (STEM ...  

Science.gov (United States)

A bright field scanning transmission electron microscope (STEM) micrograph showing a Wassonite grain in dark contrast. ...

260

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase ...

2008-12-15

261

Solvent isotope effect on the quartet #-># doublet intersystem crossing efficiencies of Cr(bpy)_3"3"+ and Cr(phen)_3"3"+"1  

International Nuclear Information System (INIS)

The intensity of luminescence from the "2E state of Cr(bpy)_3"3"+ (bpy = 2, 2'-bipyridine) is lower in D_2O, although the "2E lifetime is unchanged, indicating that the "4T_2 (precursor to "2E) is sensitive to the isotopic nature of the solvent. A photophysical mechanism is proposed for Cr(NN)_3"3"+ complexes.

262

Magnetic susceptibility of (La,Ce)B_6 alloys  

International Nuclear Information System (INIS)

The impurity susceptibility chisub(m) of the Kondo system (Lasub(1-x)Cesub(x))B_6, x <= 0.018, has been measured for temperatures 0.03-8 K. The alloys show single impurity behavior for x < 0.006. In a wide temperature range chisub(m)(T) follows a Curie-Weiss law with theta=2.8 K and turns to a T"2 law at very low temperatures. (Auth.).

1977-03-01

263

MR imaging study on external hydrocephalus in infants: extracerebral space developmental and pathological enlargement  

International Nuclear Information System (INIS)

Objective: To analyze the characteristics of external hydrocephalus in infancy with MR imaging, and to explore the cause of accumulation of extracerebral fluid and the relation with brain development. Methods: Conventional magnetic resonance T_1 weighted imaging (T_1WI) and T_2 weighted imaging (T_2WI) were performed in 46 infants aged 2 years or younger with external hydrocephalus (EH), and the results were analyzed. They were divided into 7 age groups. The width of extractable space was measured on T_2WI and compared with normal standard. Results: EH mainly resulted from infection, subdural hematoma or subarachnoid hemorrhage, HIE, which were 67.4% (31/46 cases) of the cases; EH with unknown cause were 26.1% (12/46 cases). EH was mainly located at the foreside of cerebral convexity, of which 80.4% (37/46 cases )was predominantly in the subarachnoid space, 8.7% ...

2006-05-01

264

Increased levels of the calcification marker Matrix Gla Protein and the inflammatory markers YKL-40 and CRP in patients with type 2 diabetes and ischemic heart disease  

UK PubMed Central (United Kingdom)

Objective and designLow grade inflammation is of pathogenic importance in atherosclerosis and in the development of cardiovascular disease (CVD) and type 2 diabetes (T2D). Matrix...Full Text Available

265

I_ 66- 1 Z_5 27 _O - NASA Technical Report Server (NTRS)  

Science.gov (United States)

sigma confidence of hitting a 21 km atmospheric entry corridor ...... end-point state and the end time f(X,T). (2-27) where X = Nominal end-point state. T = Nominal ..... which assumes a linear filter is given in Reference. 2 to- ...

266

Factors affecting costs and utilization of type 2 diabetes healthcare: a cross-sectional survey among 15 hospitals in urban China  

UK PubMed Central (United Kingdom)

BackgroundType 2 Diabetes mellitus (T2DM) affects persons of all ages, while also placing heavy economic burdens on national economies and healthcare systems. The study aims to investigate...Full Text Available

267

Evaluation of T-cell receptor gene rearrangements in patients with recurrent patch/plaque (T2) CTCL (mycosis fungoides).  

UK PubMed Central (United Kingdom)

Cutaneous T-cell lymphoma is typically a clonal neoplasm of epidermotropic CD4+ T-lymphocytes that includes the entity mycosis fungoides (MF). After identification of patients with recurrent MF treated...Full Text Available

1999-11-01

268

Dietary calcium and magnesium intakes and the risk of type 2 diabetes: the Shanghai Women's Health Study123  

UK PubMed Central (United Kingdom)

Background: Diet plays a key role in the development of type 2 diabetes (T2D), but little is known about the contributions of specific nutrients in populations in which dietary patterns...Full Text Available

2009-04-01

269

Curcumin eliminates oxidized LDL roles in activating hepatic stellate cells by suppressing gene expression of lectin-like oxidized LDL receptor-1  

UK PubMed Central (United Kingdom)

Type II diabetes mellitus (T2DM) is often accompanied by non-alcoholic steatohepatitis (NASH) and associated with hypercholesterolemia, i.e. increased levels of plasma low-density...Full Text Available

2009-11-01

270

Administration of a Decoction of Sucrose- and Polysaccharide-Rich Radix Astragali (Huang Qi) Ameliorated Insulin Resistance and Fatty Liver but Affected Beta-Cell Function in Type 2 Diabetic Rats  

UK PubMed Central (United Kingdom)

The current investigation attempted to confirm the beneficial actions of a chemically characterized Radix Astragali decoction (AM-W) against type 2 diabetic (T2D) Sprague-Dawley (SD) rats. Using a case/control...Full Text Available

2011-01-01

271

Theoretical considerations for X-ray phase contrast mammography by Thomson source  

Energy Technology Data Exchange (ETDEWEB)

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect ...

2009-09-01

272

What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography?  

International Nuclear Information System (INIS)

Objective: To determine the optimal contrast injection protocol for 64-MDCT coronary angiography. Materials and methods: One hundred and fifty consecutive patients scheduled to undergo retrospectively electrocardiographically gated 64-MDCT. Each 30 patients were assigned to use a different contrast protocol: group 1: uniphasic protocol (contrast injection without saline flush); group 2: biphasic protocol (contrast injection with saline flush); group 3A, 3B and 3C: triphasic protocol (contrast media + different saline diluted contrast media + saline flush). Image quality scores and artifacts were compared and evaluated on both transaxial and three-dimensional coronary artery images among each contrast protocol. Results: Among the triphasic protocol groups, group 3A (30%:70% contrast media-saline mixture was used in second ...

2010-08-01

273

MRI in preoperative evaluation of chronic paranasal sinusitis - a comparison with CT; MRT in der praeoperativen Diagnostik der chronischen Sinusitis im Vergleich mit der CT  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T{sub 2}-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts of dental work and showed more often ...

2001-04-01

274

Usefulness of "1"8F-FDG PET in intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ring-shaped uptake corresponding to ...

2003-11-01

275

High-field MR imaging in the follow-up of patients with valvular and composite tubular aortic prostheses  

International Nuclear Information System (INIS)

Eleven patients who had undergone cardiac surgery were studied by means of high-field MR imaging (1.5 T). Six patients had aortic root and valve replaced with a Bjork-Shiley (BS) composite tubular aortic graft prosthesis for acute dissection of ascending aorta. In the other 5 patients with rheumatic calcific aortic disease, the valve had been replaced with a BS prosthesis. As a whole, MR studies were 14. Previous evaluations of magnetic field effects had seem carried out ex vivo on both BS valves and BS composite prostheses, on surgical ligation clips (Tantalium and Stainless) and on stainless wires for sternal closure. In 4 patients (2 BS composite grafts, and 2 BS valves) MRI diagnosed chronic dissection of both arch and descending aorta. In 1 of them, with a bs valve, associated localized acute dissection of ascending aorta was observed. In 3 patients with BS composite grafts, MRI revealed pseudo-aneurysms (including a thrombosed one) at the ...

276

Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?  

Energy Technology Data Exchange (ETDEWEB)

(1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap ...

2007-02-15

277

Multiphasic helical CT of hepatocellular carcinoma. Evaluation after chemoembolization; Tomografia Computerizzata spirale multifasica dell'epatocarcinoma. Valutazione dopo chemioembolizzazione  

Energy Technology Data Exchange (ETDEWEB)

The main purpose of this work is to report the personal experience with addition of contrast-enhanced multiphase helical CT to unenhanced CT (Lipiodol CT) in the evaluation of patients with hepatocellular carcinoma treated with chemoembolization and to analyze the present role of oily agent CT. It has been retrospectively reviewed the examinations of 42 consecutive patients submitted to global chemoembolization over a 2-year period. CT was performed 18-30 days after the treatment. The Lipiodol CT study was carried out with volume acquisitions. It has been considered as nodules all well-defined areas with dense oily agent uptake; uptake itself was classified as: 0=absent, I=lower than 10% of the tumor volume; II=lower than 50%, III=50%, IV=homogeneous. Contrast-enhanced helical CT was performed with the 2-phase technique in 28 patients and with the 3-phase technique in 14; it has been considered as nodules all well-defined and relatively ...

2000-06-01

278

Electrical biasing and voltage contrast imaging in a focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

We present two new techniques that enhance conventional focused ion beam (FIB) system capabilities for integrated circuit (IC) analysis: in situ electrical biasing and voltage contrast imaging. We have used in situ electrical biasing to enable a number of advanced failure analysis applications including (1) real time evaluation of device electrical behavior during milling and deposition, (2) verification of IC functional modifications without removal from the FIB system, and (3) ultraprecision control for cross sectioning of deep submicron structures, such as programmed amorphous silicon antifuses. We have also developed FIB system voltage contrast imaging that can be used for a variety of failure analysis applications. The use of passive voltage contrast imaging for defect localization and for navigation on planarized devices will be illustrated. In addition, we describe new, biased voltage contrast ...

1995-09-01

279

The influence of normal human ageing on automatic movements  

British Library Electronic Table of Contents (United Kingdom)

There is evidence that aged normal subjects have more difficulty in achieving automaticity than young subjects. The underlying central neural mechanism for this phenomenon is unclear. In the present study, functional magnetic resonance imaging (fMRI) was used to investigate the effect of normal ageing on automaticity. Aged healthy subjects were asked to practice self-initiated, self-paced, memorized sequential finger movements with different complexity until they could perform the tasks automatically. Automaticity was evaluated by having subjects perform a secondary task simultaneously with the sequential movements. Although it took more time, most aged subjects eventually performed the tasks automatically at the same level as the young subjects. Functional MRI results showed that, for bot...

2005-01-01

280

Targeted drug delivery under MRI guidance  

British Library Electronic Table of Contents (United Kingdom)

The main goal of local drug delivery is to increase the concentration of a specific therapeutic agent in a target tissue with minimal nontarget distribution. Compared to systemic therapy, local drug delivery provides a high level of therapeutic efficacy with minimal systemic effects. The current primary imaging modality for drug delivery has been x-ray angiography, but it has major limitations including anatomical ambiguity and inability to visualize the targeted tissues. Due to these inherent problems, MR guidance has been explored as an alternative imaging modality for guiding and monitoring of drug therapy. Recently, interventional MR (XMR) systems have been implemented that have both dual x-ray and MRI capabilities in a single suite and allow for real-time interventional procedures to ...

2008-01-01

281

Parallel MRI reconstruction using variance partitioning regularization  

British Library Electronic Table of Contents (United Kingdom)

Multiple receivers can be utilized to enhance the spatiotemporal resolution of MRI by employing the parallel imaging technique. Previously, we have reported the L-curve Tikhonov regularization technique to mitigate noise amplification resulting from the geometrical correlations between channels in a coil array. Nevertheless, one major disadvantage of regularized image reconstruction is lengthy computational time in regularization parameter estimation. At a fixed noise level, L-curve regularization parameter estimation was also found not to be robust across repetitive measurements, particularly for low signal-to-noise ratio (SNR) acquisitions. Here we report a computationally efficient and robust method to estimate the regularization parameter by partitioning the variance of the noise-white...

2007-01-01

282

Magnetic separation anxiety  

International Nuclear Information System (INIS)

This paper reports that only a few years ago superconducting magnetic separation was viewed as the next major market for superconducting magnets. The first commercial units had been installed, worked flawlessly, and demonstrated real economic viability. The potential market was seen as quite large, and many people believed that superconducting magnetic separation would soon show the same rapid growth that MRI had demonstrated after its initial success. These hopes even prompted IGC, one of the top MRI magnet builders, to form a separate division devoted to magnetic separation. Despite the existence of Magstream, IGC has not been overly active in the market. As a technology that has applications from the clay on the Earth to the soil on the moon, superconducting magnetic separation has yet to become widely used.

1992-01-01

283

Magnetic resonanse imaging in otorhinolaryngology. With special reference to the influence of factors upon NMR parameters and differential diagnosis of otorhinolaryngic lesions  

Energy Technology Data Exchange (ETDEWEB)

MRI diagnosis for malignant tumors are made possible by direct comparison to the results obtained by the brain and it seems possible to differentiate malignant tumors from other benign lesions. Cystic lesions, and mycotic sinusitis sometimes resemble malignant tumors in MR Image. In the present report, we investigated the relationships between the biochemical contents of cystic lesions and NMR-parameters to clarify why some inflammatory lesions appeared similar to malignant tumors in MRI. The variation of relaxation time depends upon the amount of protein in the cystic contents and the amount of glucose affects the relaxation time. We conclude that NMR-parameters are useful for the differential diagnosis of malignant tumors, cystic lesions and mycositic sinusitis by using the multiple variation analysis.

1987-07-01

284

Impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)

2009-10-01

285

Evaluation of cortical current density imaging methods using intracranial electrocorticograms and functional MRI  

British Library Electronic Table of Contents (United Kingdom)

Objective:EEG source imaging provides important information regarding the underlying neural activity from noninvasive electrophysiological measurements. The aim of the present study was to evaluate source reconstruction techniques by means of the intracranial electrocorticograms (ECoGs) and functional MRI.Methods:Five source imaging algorithms, including the minimum norm least square (MNLS), LORETA with Lp-norm (p equal to 1, 1.5 and 2), sLORETA, the minimum Lp-norm (p equal to 1 and 1.5; when p=2, the MNLS method is mathematically equivalent to the minimum Lp-norm) and L1-norm (the linear programming) methods, were evaluated in a group of 10 human subjects, in a paradigm with somatosensory stimulation. Cortical current density (CCD) distributions were estimated from the scalp somatosensor...

2007-01-01

286

Development of a Full Body CAD Dataset for Computational Modeling: A Multi-modality Approach  

British Library Electronic Table of Contents (United Kingdom)

The objective of this study was to develop full body CAD geometry of a seated 50th percentile male. Model development was based on medical image data acquired for this study, in conjunction with extensive data from the open literature. An individual (height, 174.9?cm, weight, 78.6???0.77?kg, and age 26?years) was enrolled in the study for a period of 4?months. 72 scans across three imaging modalities (CT, MRI, and upright MRI) were collected. The whole-body dataset contains 15,622 images. Over 300 individual components representing human anatomy were generated through segmentation. While the enrolled individual served as a template, segmented data were verified against, or augmented with, data from over 75 literature sources on the average morphology of the human body. Non-Uniform Rational...

2011-01-01

287

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

288

Nitrogen Requirements and Balance of Protected Cucumber in Coastal Lebanon  

International Nuclear Information System (INIS)

Protected cultures are widespread along the Lebanese narrow coastline, encouraged by mild winter conditions. Although one of the most intensive production systems, water and nutrients managements are mostly empirical, based on the experience of the grower himself or of his workers. So far, water has been available in Lebanon, but it will become scarce within ten years. The conservation of water quality by a rational addition of nutrients is particularly relevant to protected cultures. This is important as greenhouses are developed on imported shallow soils that could be fragile and highly vulnerable to pollution. Sound management includes the amount and the forms of fertilizers as well as the modality of fertigation. An experiment was conducted during two spring seasons in a location along the northern coast in a typical unheated greenhouse. The cucumber response to two frequencies and modalities of fertigation was followed: continuous T2C and ...

2003-10-01

289

Magnetism in "3He  

International Nuclear Information System (INIS)

The nuclear magnetic susceptibility, #chi#, of "3He is seen to nearly obey a pure Curie Law, #chi# = C/T, over the temperature range 0.5 mK < T < 2 K when contained in the 20#ALPHA#, multiply connected pores of Vycor glass at low external pressure. Raising the external pressure to 5 bar (1 bar 100 kPa) causes the susceptibility to obey the Curie-Weiss law, #chi# = C' /T - #THETA# whose #THETA# = 0.3 mK. The longitudinal relaxation time, T_1, varies monotonically with T between 17 and 90 ms at both pressures. At 5 bar, the transverse relaxation time T_2*, is nearly temperature independent (about 600 #mu#s) above 2 mK. Below 2 mK, T_2* drops precipitously. Preliminary measurements indicate that the magnetism is produced by atoms that can flow through the pores of the Vycor glass. (10 refs., fig.).

1986-10-01

290

L'exercice physique d'endurance est plus efficace que l'exercice aerobie pour le controle par la pression arterielle sur 24heures chez des diabetiques de type 2  

British Library Electronic Table of Contents (United Kingdom)

Aim: The study aimed to analyze blood pressure (BP) responses in individuals with type 2 diabetes (T2D) over a 24h period following resistance (RES) and aerobic (AER) exercise. Methods: Ten adults with T2D (age: 55.8+/-7.7 years; weight: 79.4+/-14.0kg; fasting glucose: 133.0+/-36.7mg.dL^-^1) underwent: (1) AER: 20min of cycling at 90% lactate threshold (90% LT); (2) RES: three laps of a circuit of six exercises with eight repetitions at 70% 1-RM and 40s of recovery; and (3) a control session of no exercise. Heart rate (HR), and systolic (SBP), diastolic (DBP), mean arterial (MAP) and pulse (PP) BP, as well as lactataemia (Lac), VO2, respiratory exchange ratio (RER) and rate of perceived exertion (RPE) were measured at rest, during exercise and control (CON) periods, and 60min after interve...

2011-01-01

291

Enthalpy measurements of La_2Te_3O_9 and La_2Te_4O_1_1  

International Nuclear Information System (INIS)

Enthalpy increment measurements on La_2Te_3O_9(s) and La_2Te_4O_1_1(s) were carried out using a Calvet micro-calorimeter. The enthalpy values were analyzed using the non-linear curve fitting method. The dependence of enthalpy increments with temperature was given as: H"o(T) - H"o(298.15 K) (J mol"-"1) = 360.70T + 0.00409T "2 + 133.568 x 10"5/T - 149 923 (373 #<=# T (K) #<=# 936) for La_2Te_3O_9 and H"o(T) - H"o(298.15 K) (J mol"-"1) = 331.927T + 0.0549T "2 + 29.3623 x 10"5/T - 114 587 (373 #<=# T (K) #<=# 936) for La_2Te_4O_1_1.

2007-02-01

292

Hypothalamic control of energy and glucose metabolism  

British Library Electronic Table of Contents (United Kingdom)

The central nervous system (CNS), generally accepted to regulate energy homeostasis, has been implicated in the metabolic perturbations that either cause or are associated with obesity. Normally, the CNS receives hormonal, metabolic, and neuronal input to assure adequate energy levels and maintain stable energy homeostasis. Recent evidence also supports that the CNS uses these same inputs to regulate glucose homeostasis and this aspect of CNS regulation also becomes impaired in the face of dietary-induced obesity. This review focuses on the literature surrounding hypothalamic regulation of energy and glucose homeostasis and discusses how dysregulation of this system may contribute to obesity and T2DM.

2011-01-01

294

Value of MRCP using oral Gd-DTPA as negative contrast materials in diagnosis of atypical juxtapapillary duodenal diverticulum  

British Library Electronic Table of Contents (United Kingdom)

Objective To investigate value of magnetic resonance cholangiopancreatography (MRCP) using oral diluted gadolinium (Gd)-diethylenetriamine penta-acetic acid (DTPA) as negative contrast materials in diagnosis of juxtapapillary duodenal diverticulum with atypical imaging features. Methods Nineteen patients with juxtapapillary duodenal diverticula of which imaging findings were atypical underwent MRCP using oral diluted Gd-DTPA as negative contrast materials after conventional MRCP without any oral contrast materials. Results Twenty diverticula were revealed in the 19 patients. At conventional MRCP, the diverticula appeared as rounded lesion with high signal intensity. After oral administration of diluted Gd-DTPA, they disappeared at MRCP. These entities were diagnosed as duodenal diverticula...

2009-01-01

295

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

296

Symbiotic regulation of plant growth, development and reproduction  

UK PubMed Central (United Kingdom)

The growth and development of rice (Oryzae sativa) seedlings was shown to be regulated epigenetically by a fungal endophyte. In contrast to un-inoculated (nonsymbiotic) plants, endophyte...Full Text Available

2009-03-01

297

Physiological and Biochemical Variations during the Molt Cycle in Juvenile Litopenaeus vannamei under Laboratory ...  

Science.gov (United States)

... 05). In contrast with the information available for Penaeus monodon Fabricius, 1798 (Ferraris et al., 1987) and L. vannamei ( ... ...

298

Interaction of legionella pneumophila and helicobacter pylori with bacterial species isolated from drinking water biofilms  

UK PubMed Central (United Kingdom)

BackgroundIt is well established that Legionella pneumophila is a waterborne pathogen; by contrast, the mode of Helicobacter pylori transmission...Full Text Available

299

Double plasma mirror for ultrahigh temporal contrast ultra-intense laser pulses  

International Nuclear Information System (INIS)

We present and characterize a very efficient optical device that employs the plasma mirror technique to increase the contrast of high-power laser systems. Contrast improvements higher than 104 with 50% transmission are shown to be routinely achieved on a typical 10 TW laser system when the pulse is reflected on two consecutive plasma mirrors. Used at the end of the laser system, this double plasma mirror preserves the spatial profile of the initial beam, is unaffected by shot-to-shot fluctuations, and is suitable for most high peak power laser systems. We use the generation of high-order harmonics as an effective test for the contrast improvement produced by the double plasma mirrors. (authors)

300

Digital subtraction angiography with scanning lazer stimulated luminescence  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was ...

1985-01-01

302

Contrast Sensitivity and Optical Quality of the Eye after Instillation of Timolol Maleate Gel-Forming Solution and Brinzolamide Ophthalmic Suspension  

British Library Electronic Table of Contents (United Kingdom)

Purpose To investigate the influence of timolol maleate 0.5% gel-forming solution and brinzolamide 1% ophthalmic suspension on contrast sensitivity, ocular higher-order aberration (HOA), and corneal surface light scattering. Design Prospective, comparative study. Participants Forty normal volunteers were enrolled in this study. Methods We evaluated contrast sensitivity, ocular HOA, and corneal light scattering before and 2, 5, 10, and 15 minutes after instillation of antiglaucoma eyedrops. Contrast sensitivity function was assessed with the CSV-1000RN chart (Vector Vision Co., Greenville, OH). Higher-order aberration was measured for a 4-mm pupil using the Hartmann-Shack aberrometer (KR-9000PW; Topcon, Tokyo, Japan). Corneal surface light scattering was quantitatively evaluated by using th...

2010-01-01

303

Chronic kidney disease in children: the global perspective  

UK PubMed Central (United Kingdom)

In contrast to the increasing availability of information pertaining to the care of children with chronic kidney disease (CKD) from large-scale observational and interventional studies, epidemiological...Full Text Available

2007-12-01

304

Cancer as a metabolic disease  

UK PubMed Central (United Kingdom)

Emerging evidence indicates that impaired cellular energy metabolism is the defining characteristic of nearly all cancers regardless of cellular or tissue origin. In contrast to normal cells, which...Full Text Available

305

10% low density corn-oil emulsion oral contrast agent for abdominal computed tomography  

Energy Technology Data Exchange (ETDEWEB)

CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% ...

1990-10-15

306

10% low density corn-oil emulsion oral contrast agent for abdominal computed tomography  

International Nuclear Information System (INIS)

CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is ...

1990-10-01

307

Whole-body tumor staging: MRI or FDG-PET/CT?; Ganzkoerpertumorstaging: MRT oder FDG-PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Technical innovations such as the availability of movable patient platforms and the introduction of 32-channel systems have made whole-body MRI for tumor staging feasible. In addition, the development of dual-modality PET/CT systems offers the opportunity to perform anatometabolic tumor staging with whole-body coverage in a single session. Based on an increase in patient survival when applying a stage-adapted therapy in different malignant diseases the relevant question relates to the accuracies of whole-body MRI and whole-body PET/CT for TNM staging. This review article addresses whole-body tumor staging with MRI and FDG-PET/CT with special emphasis on diagnostic accuracies for staging different malignant diseases. (orig.) [German] Technische Neuerungen, wie die Verfuegbarkeit beweglicher Tischaufsaetze oder die Einfuehrung von 32-Kanal-Systemen, haben die Ganzkoerperbildgebung mit der MRT ermoeglicht. Die Entwicklung ...

2004-09-01

308

The Growth of an Extrapancreatic Solid Pseudopapillary Tumor from the Greater Omentum: A Case Report  

Energy Technology Data Exchange (ETDEWEB)

A solid pseudopapillary tumor is an uncommon tumor of the pancreas that rarely metastasizes to other organs and usually shows good prognosis. An extrapancreatic tumor arising from a solid pseudopapillary tumor is very rare. We report a case of an atypical extrapancreatic solid pseudopapillary tumor that arose from the great omentum and disseminated to the peritoneum, and discuss the radiologic findings, including the CT, US, and MRI.

2010-01-15

309

The Growth of an Extrapancreatic Solid Pseudopapillary Tumor from the Greater Omentum: A Case Report  

International Nuclear Information System (INIS)

A solid pseudopapillary tumor is an uncommon tumor of the pancreas that rarely metastasizes to other organs and usually shows good prognosis. An extrapancreatic tumor arising from a solid pseudopapillary tumor is very rare. We report a case of an atypical extrapancreatic solid pseudopapillary tumor that arose from the great omentum and disseminated to the peritoneum, and discuss the radiologic findings, including the CT, US, and MRI

2010-01-01

310

Quantitative 31P NMR Spectroscopy and 1H MRI Measurements of Bone Mineral and Matrix Density Differentiate Metabolic Bone Diseases in Rat Models  

UK PubMed Central (United Kingdom)

In this study, bone mineral density (BMD) of normal (CON), ovariectomized (OVX) and partially nephrectomized (NFR) rats was measured by 31P NMR spectroscopy; bone matrix density was...Full Text Available

2010-06-01

311

Prognostic value of dynamic MRI in assessing post-traumatic femoral head vascularity  

Energy Technology Data Exchange (ETDEWEB)

The vascular status of femoral heads in the post-traumatic period of intracapsular femoral neck fracture (ICFNF) remains uncertain until the patient actually develops avascular necrosis (AVN). Several methods for predicting the viability of femoral head have been reported, that are not effective or widely used because of unreliability, potential complications, and technical difficulties. The present study involved the use of Dynamic MRI (DMRI) in assessing femoral head vascularity to predict AVN. The role of DMRI was studied prospectively in 30 patients with 31 ICFNF. Fractures were divided in to three types (Type A, B, or C) based on the femoral head vascularity shown by dynamic curve patterns on MRI evaluation. Type A was preserved vascularity, Type B was some decrease in vascularity but still viable while Type C was significantly reduced vascularity. These were followed-up for 6 months to 2 years to observe the final outcome in terms of ...

2009-06-15

312

Morphometric analysis of the temporomandibular joint with MRI in 320 joints; Morphometrische Analyse des Kiefergelenkes anhand von 320 Gelenken mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Purpose: to compare several morphometric parameters in MRI with the functional status of the articular disc in a large patient group suffering from internal derangement (ID) of the temporomandibular joint (TMJ). Materials and methods: in a retrospective study, 320 analyzable high resolution MRI examinations of the TMJs obtained in a 1.5 T unit were evaluated in 184 patients with clinically suspected ID. The analysis included the anatomical structures and a number of morphometric parameters previously described in the literature. The parameters were compared with the position of the articular disc. Results: the disc position was categorized as ''normal'' (NDP, 21.9%, n = 70), ''anterior displacement with reduction on opening'' (AMR, 51.6%, n = 165) and ''anterior displacement without reduction on opening'' (AOR, 26.6%, n = 85). With ...

2005-02-01

313

MRI survival guide; MRT Basiskurs  

Energy Technology Data Exchange (ETDEWEB)

The book is a German translation of an American textbook with the original title ''MRI Survival Guide'' and is intended to serve as an introductory guide for beginners or a reference book for quick information. Readers will find information on the fundamentals of the technology and methodology of MRI as well as all details of relevance to practice in a precise and easy-to-grasp arrangement, covering all anatomic areas of interest, illustrations and descriptions of characteristic signs of pathologic processes, high-quality and unusually large-sized diagnostic pictures, a modern didactic concept for quick orientiation, including surveys, tables, and reproductions for visualisation of contents. (orig./CB) [German] Praktisch jeder Mediziner wird im Laufe seiner Berufstaetigkeit mit der MRT konfrontiert - unabhaengig davon ob in der Radiologie, Orthopaedie, Gynaekologie, Chirurgie, Neurologie oder sonstigen ...

1999-07-01

314

MRI of the pancreas: Radiological-pathological correlation; MRT des Pankreas: Radiologisch-pathologische Korrelation  

Energy Technology Data Exchange (ETDEWEB)

The typical MRI features of the most common pancreatic diseases, such as pancreatitis and adenocarcinoma of the pancreas, have been established. However, even in these common pancreatic disorders, MRI correlation with the underlying pathology is limited for clinical reasons. We emphasize MR-pathological correlation of inflammatory and neoplastic pancreatic changes, including pancreatitis, adenocarcinoma, acinar cell carcinoma, rare cystic and solid pancreatic neoplasms, and islet cell tumors. By highlighting the correlation of key pathological features with MR findings, a better understanding of the MR appearance of pancreatic pathology can be provided. In addition, MRI may prove a powerful tool in detection and characterization of pancreatic tumors. (orig.) [Deutsch] Das MR-tomographische Erscheinungsbild von Pankreatitiden und Adenokarzinomen des Pankreas, als den haeufigsten Pankreaserkrankungen, ist zwar ausreichend ...

1996-05-01

315

MR findings of primary Ewing's sarcoma of greater wing of sphenoid  

International Nuclear Information System (INIS)

Primary Ewing's sarcoma of the skull is a very rare entity. We report MRI findings in a case of Ewing's sarcoma of the greater wing of sphenoid in a 4-year-old patient. Magnetic resonance imaging showed markedly heterogenous signal intensity with areas of haemorrhage and necrosis. It also demonstrated the exact extent of tumour due to its multiplanar capabilities and was, therefore, helpful in planning surgery. Copyright (2002) Blackwell Science Pty Ltd

2002-12-01

316

MRI of congenital heart disease in childhood; MR-Tomographie kongenitaler Herzvitien im Kindesalter  

Energy Technology Data Exchange (ETDEWEB)

MRI provides a non-invasive diagnostic tool complementing echocardiography on one hand, and showing advantages over echocardiography, on the other hand, especially after corrective procedures. The multiple different MRI sequences need to be adapted to examinations of children and patients with congenital heart disease (CHD), and can be used to detect morphologic changes, blood-flow in the heart and thoracic vessels and diastolic or systolic function of myocardium. Several factors determine the success of the examination of a complex congenital heart disease or a postoperative situs. Pediatric radiologists and radiologists experienced in congenital heart diseases have to work in close cooperation. Echocardiography should be performed before MRI. The results of prior examinations and the clinical history of the patients, including possible palliative or reconstructive operations, must be available before ...

2004-02-01

317

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences; Funktionelle MRT des Pharynx bei obstruktiver Schlafapnoe (OSA) mit schnellen 2D-FLASH-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager (`Vision`, Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and ...

1996-03-01

318

Multiple imaging radiography at LNLS  

Energy Technology Data Exchange (ETDEWEB)

An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.

2008-01-11

319

Computer tomographic ventriculography  

Energy Technology Data Exchange (ETDEWEB)

A method for elucidating complex abnormalities of CSF circulation by using a positive contrast medium (metrizamide) and computer tomography is described. The technique for the method, the results and their clinical significance is demonstrated. The value of this method is compared with traditional ventriculography and with computer tomography without the use of contrast medium. It is shown that the technique represents an important extension of the scope of computer tomography.

1982-04-01

320

New procedures. Comprehensive staging of lung cancer by MRI; Neue Verfahren. Umfassendes Staging des Lungenkarzinoms mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Lung cancer staging according to the TNM system is based on morphological assessment of the primary cancer, lymph nodes and metastases. All aspects of this important oncological classification are measurable with MRI. Pulmonary nodules can be detected at the clinically relevant size of 4-5 mm in diameter. The extent of mediastinal, hilar and supraclavicular lymph node affection can be assessed at the same time. The predominant metastatic spread to the adrenal glands and spine can be detected in coronal orientation during dedicated MRI of the lungs. Search focused whole body MRI completes the staging. Various additional MR imaging techniques provide further functional and clinically relevant information during a single examination. In the oncological context the most important techniques are imaging of perfusion and tumor motion. Functional MRI of the lungs complements the pure staging and improves ...

2010-08-15

321

Magnetic resonance imaging in the evaluation of pneumonia; Nachweis von pneumonischen Infiltraten mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) of the lung is challenging because of substantial drawbacks. However, lung pathologies that are associated with increased attenuation values in CT enhance visualization in MRI: proton density is increased and tissue-air interfaces, resulting in susceptibility artifacts, are reduced in pneumonia, pneumonitis, edema, and carcinoma. On the other hand, many lung diseases result in shortness of breath, so that patients cannot hold their breath for long periods. Therefore, fast imaging techniques are required which should also allow for high spatial resolution so that small lesions can be detected. Calcifications and air pockets within lesions are not readily recognized with MRI. Thin section CT is standard for the diagnosis of pneumonia. With parallel imaging techniques, MRI examination of the lungs can be performed with short periods of breath holding, which allow for ...

2006-04-15

322

MRI in postoperative assessment of univentricular heart disease: correlation with echocardiography and angiography; MRT in der postoperativen Diagnostik bei funktionell univentrikulaerem Herz: Korrelation zu Echokardiographie und Kardangiographie  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the value of MRI in the postoperativ evaluation of a singular ventricle compared to echocardiography and cardiac catheterization. Materials and methods: Thirty-one patients (range: 6 months to 30 years) with a functional single ventricle following palliative corrective operations. Five patients had a Blalock-Taussig-Shunt, 8 patients a Glenn-Anastomosis and 18 a cavopulmonary shunt (6 with classic Fontan-Circulation, 12 with modified cavopulmonary anastomosis). The results in terms of postoperative morphologic changes were compared to percutaneous echocardiography (31/31) and cardiac catheterization (6/31). Results: Echocardiography, which was performed on all patients, could not visualize the entire length of the tunnel, the Glenn-Anastomosis or the central pulmonary arteries in 70% of the patients due to an inadequate acoustic window. MRI was able to show the entire tunnel in 11/12 patients and the central pulmonary ...

2002-12-01

323

Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI; Untersuchung der atemabhaengigen Bewegungen pulmonaler Raumforderungen mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be the appropriate tool ...

2009-08-15

324

Wavelength-Dependent Differential Interference Contrast Microscopy: Selectively Imaging Nanoparticle Probes in Live Cells  

Energy Technology Data Exchange (ETDEWEB)

Gold and silver nanoparticles display extraordinarily large apparent refractive indices near their plasmon resonance (PR) wavelengths. These nanoparticles show good contrast in a narrow spectral band but are poorly resolved at other wavelengths in differential interference contrast (DIC) microscopy. The wavelength dependence of DIC contrast of gold/silver nanoparticles is interpreted in terms of Mie's theory and DIC working principles. We further exploit this wavelength dependence by modifying a DIC microscope to enable simultaneous imaging at two wavelengths. We demonstrate that gold/silver nanoparticles immobilized on the same glass slides through hybridization can be differentiated and imaged separately. High-contrast, video-rate images of living cells can be recorded both with and without illuminating the gold nanoparticle probes, providing definitive probe identification. Dual-wavelength ...

2009-11-15

325

CT diagnosis of intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To evaluate contrast-enhanced CT scan in the diagnosis of intrahepatic cholangiocarcinoma by correlating the CT appearance with pathologic specimens. Materials and methods: Twenty-eight patients with pathologically proven intrahepatic cholangiocarcinoma were examined. Unenhanced abdominal CT study were performed in 28 patients; conventional contrast-enhanced CT in 27 patients. Enhanced CT scan including fast injection, fast scan and delayed scan at the largest section of the lesion was done in 7 patients. Contiguous 10 mm CT scans of the surgical specimens were also obtained in 8 patients. The preoperative and specimen CT scans in these 8 patients were compared with the corresponding pathological sections. A total of 103 areas of the pathological sections was compared with the CT appearances. Results: All lesions contained areas of delayed contrast enhancement and/or no enhancement on CT examinations. The areas of ...

326

MRI in the diagnosis of non-compacted ventricular Myocardium (NCVM) compared to echocardiography; MR-Tomographie in der morphologischen Darstellung der isolierten non-compaction des linksventrikulaeren Myokards (NCVM)  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To report the detection of con-compacted ventricular myocardium (NVCM) with MRI compared to echocardiography in 8 patients. Material and methods: Non-compaction of the ventricular myocardium is a congenital disorder characterized by an altered structure of the myocardial wall resulting from an intrauterine arrest in endomyocardial embryogenesis. The morphological findings consist of a prominent meshwork of multiple myocardial trabeculations and deep intertrabecular recesses, communicating with the left ventricular cavity. 8 consecutive patients (mean age 7.3 years) with clinical and echocardiographic signs of NCVM were examined by MRI (1.5 T, Vision, Siemens) in short axis and 2- and 4-chamber views, using T{sub 1}-weighted TSE and Cine-GRE in 6 patients and true FISP sequences in 2 patients. MRI and echocardiography were evaluated for visibility, signs of NCVM and involvement of myocardial wall segments. Thickness ...

2003-09-01

327

Staging of multiple myeloma with MRI: comparison to MSCT and conventional radiography; Staging des multiplen Myeloms mit der MRT: Vergleich zur MSCT und zur konventionellen Roentgendiagnostik  

Energy Technology Data Exchange (ETDEWEB)

The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector ...

2004-09-01

328

Phase- and size-adjusted CT cut-off for differentiating neoplastic lesions from normal colon in contrast-enhanced CT colonography  

Energy Technology Data Exchange (ETDEWEB)

A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps <10 mm, 13 polyps {>=}10 mm, 24 carcinomas) were determined by region-of-interest (ROI) measurements in 38 patients who underwent contrast-enhanced CTC. In addition, the height (H) of the colonic lesions was measured in CT. CT values were also measured in the aorta (A), superior mesenteric vein (V) and colonic wall. The contrast phase was defined by xA + (1 - x)V using x as a weighting factor for describing the different contrast phases ranging from the pure arterial phase (x=1) over the intermediate phases (x=0.9-0.1) to the pure venous phase (x=0). The CT values of the lesions were correlated with their height ...

2004-12-01

329

Reduction of fluoroscopic exposure for the air-contrast barium enema  

Energy Technology Data Exchange (ETDEWEB)

In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a variable-sized operator-selectable iris diaphragm would permit this dose-reduction approach to ...

1983-11-01

330

Magnetization transfer contrast effect on multislice fast spin echo  

Energy Technology Data Exchange (ETDEWEB)

Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).

1994-03-01

331

Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography  

British Library Electronic Table of Contents (United Kingdom)

Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...

2011-01-01

332

Diagnostic quality in hysterosalpingography  

International Nuclear Information System (INIS)

Purpose: To compare the diagnostic quality and adverse events of the water-soluble, non-ionic, iso-osmolar, dimeric contrast media iodixanol and iotrolan in hysterosalpingography (HSG). Material and Methods: One hundred and twenty patients participated in a double-blind randomized parallel-group phase-III study. Questionnaires and patient interviews were used. Diagnostic quality was assessed using a visual analogue scale and the quality in specific regions was rated using a categorical scale. Results: Overall diagnostic quality was equal for the two groups. There was no statistically significant difference between the two groups in diagnostic quality in the specific regions of interest. No differences between the contrast media were found with regard to adverse events. Conclusion: Both contrast media provided images of high diagnostic quality in HSG. (orig.)

1998-11-01

333

Contrast material extravasation following upper abdominal trauma. Detection with helical Computerized Tomography  

International Nuclear Information System (INIS)

Active contrast material extravasation can be recognized with conventional CT scanners, though it has been considered a rare finding. Helical CT seems to increase the detection rate and especially to boost the radiologist's confidence in this diagnosis. Though active bleeding is defined in severely-injured subjects requiring urgent intervention and may be associated with findings of hypovolaemic shock, it should not be considered itself as a negative prognostic factor. Contrast extravasation is due to ongoing hemorrhage and its detection is critical for urged treatment. Accurate anatomical location permits to choose surgical management or transcatheter embolization and thus decreases time consumption for precis e bleeding site identification.

1999-03-01

334

Colour contrast in ballistic gelatine  

British Library Electronic Table of Contents (United Kingdom)

Gelatine is a reliable tissue simulant in wound ballistic experiments. The projectile penetrating the gelatine transfers energy and causes radial cracks according to the temporary cavity. Thus the crack length is a function of the energy spent in the medium. In practice the fissures are poorly contrasted for which reason an enhancement of contrast was searched. A series of six shoots with expanding bullets (9mmx19 Action-5, 9mmx19 Quick Defense 1, 5.56mmx45 Styx Action) was realized on 10% gelatine blocks at 4^oC temperature. Three blocks were marked with acryl paint on the front, three blocks were shot native. The blocks were cut in slices of 1cm thickness and optically scanned. The evaluation was performed according to Fackler's wound profile, the total crack length method and the polygo...

2010-01-01

335

Vibron and roton bands in the first overtone of solid and liquid parahydrogen  

Energy Technology Data Exchange (ETDEWEB)

The infrared spectrum of the rotovibrational band {ital v}=0{r_arrow}2 of parahydrogen has been observed in the condensed phases down to {ital T}=2 K. In the solid, phonon and roton sidebands exhibit peaks corresponding to those observed in the fundamental. Contributions arising from the reorientation of ortho-H{sub 2} impurities have been detected. The {ital Q}{sub 1}(0)+{ital S}{sub 1}(0) band has been resolved into an asymmetric doublet, and the origin of this latter is discussed. In the liquid phase the observed line shapes include strong translational contributions, and are accounted for by assuming that at short times the excited molecule is encapsulated in the cage of nearest neighbors.

1994-03-01

336

Polymers and paper as packaging materials of irradiated food  

International Nuclear Information System (INIS)

Effects of #gamma#-irradiation on synthetic polymers and paper used as packaging materials for irradiated food have been studied by NMR. Polystyrene, polybutadiene and some copolymers were studied before and after the #gamma#-irradiation treatment and in the presence or absence of antioxidants and stabilisers. In the absence of additives, the effect of #gamma#-irradiation on polystyrene is negligible even irradiating at high doses. In turn, the role of antioxidants and stabilisers is crucial in polybutadiene and butadiene-containing copolymers. Wood pulp paper was also studied by NMR. Preliminary measurements on #gamma#-irradiated wood pulp sheets show a shortening in the T_2 relaxation time component due to the bound water, i.e. some of the bound water is lost. (author)

2000-03-01

337

Phytoplankton bloom in commercial shrimp ponds using green-water technology  

British Library Electronic Table of Contents (United Kingdom)

Phytoplankton community composition, density, and succession were studied in tropical commercial ponds with euryhaline tiger shrimp (Penaeus monodon Fabricius) using green-water technology at two different stocking densities [T1 10 post-larvae (PL) m?2 and T2 15 PL m?2] in one grow-out season (May?October 2005) in Leganes, Iloilo, Philippines. Weekly qualitative and quantitative analyses of phytoplankton were done along with physicochemical analyses of the pond waters. A total of 103 taxa belonging to nine different algal classes were observed. Of these classes, the Chlorophyceae, Cyanophyceae and Bacillariophyceae constituted the great bulk of the phytoplankton population. The two treatments did not show any significant differences in the growth pattern of phytoplankton over time and in t...

2007-01-01

338

Outcomes of extremely low risk prostate cancer following radical prostatectomy  

British Library Electronic Table of Contents (United Kingdom)

The optimal management of men with very favorable clinicopathological factors who develop biochemical recurrence (BCR) after radical prostatectomy (RP) has not been previously reported. Both local and systemic recurrences are unlikely in this cohort. This study examines their management and outcomes. Between October 2000 to March 2010, 1627 men underwent open RP by a single surgeon. In all, 448 (27.5%) met the following criteria for extremely low risk disease: preoperative PSA level <10?ng?ml?1, clinical stage T1c/T2a, Gleason score ?6, estimated cancer volume in the surgical specimen ?5% and no evidence for positive surgical margin. Undetectable PSA was defined as ?0.04?ng?ml?1. BCR was defined as PSA ?0.2?ng?ml&#...

2011-01-01

339

Molecular insights from bariatric surgery  

British Library Electronic Table of Contents (United Kingdom)

Bariatric surgical procedures have become important therapeutic options for treatment of morbid obesity in both adults and adolescents co-morbidities of obesity such as glucose intolerance, type 2 diabetes (T2DM), metabolic syndrome, steatohepatitis, hyperlipidemia and cardiovascular disease. These co-morbidities of obesity have significant impacts on the overall quality of life of the individual and our society at large. Roux-en-Y gastric bypass (RYGB) and the relatively newer procedures of gastric banding (GB) and vertical sleeve gastrectomy (VSG) have proven to be efficacious in achieving rapid weight loss and reversing the comorbidities of obesity. Unfortunately, bariatric procedures are not without risks including micronutrient deficiency, failure to maintain lost weight, and mortalit...

2011-01-01

340

Laser-Cooling of Liquid Water by the Ar-Xe Laser Radiation  

CERN Document Server

An effect of laser-cooling of water was observed for the first time with a temperature decrease dT = -2.2 K after irradiation of liquid water surface by a powerful Ar-Xe pulse laser with a pulse energy of about 1 J and wavelength L = 1.73, 2.63 and 2.65 um. The discovered effect can apparently be ascribed to the optical excitation of vibrational states of H2O molecules followed by an endothermic consolidation of chemically active excited molecules into a quasi-stable cluster-like structure. The measured time dependences of the cooling effect show that a typical life time of the new state of water amounts to hours. It has also been shown that the life time of the excited vibrational molecular states due to a radiation trapping effect can be estimated to at least hundreds of seconds.

2010-01-01

341

Free air flows for the removal of pollutants from car parks. Air-conditioning systems without sheet-metal ducts as an alternative to transverse ventilation with sheet-metal ducts. Pt. 2. Freie Luftstroemungen entsorgen Parkraeume. RLT-Anlagen ohne Blechkanaele als Alternative zur Querlueftung mit Blechkanaelen. T. 2  

Energy Technology Data Exchange (ETDEWEB)

In parking areas of large extent, the removal of engine exhaust gases, especially of their CO gas components with ventilation plant is mainly done by transverse ventilation over short paths. By their presence, the ventilation ducts required for this purpose often reduce the value of the parking space by restrictions with a consequent reduction of their acceptance by the users. Longitudinal ventilation without ducts can be a remedy in such cases. Depending on the required room air quality in the zones of highest loading, the volume flows with longitudinal removal are no greater than with conventional transverse ventilation. This article is concerned with the different methods of operation of the two systems. (orig./BWI)

1994-04-01

342

Effects of pork/beef levels and various casings on quality properties of semi-dried jerky  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to investigate the effects of pork/beef levels and the casings on the quality properties of semi-dried jerky. The pork/beef levels in the four test formulations were as follows: T-1 (pork: beef=100:0), T-2 (95:5), T-3 (90:10), and T-4 (80:20). After tumbling for 30min with curing solution, the cured meats were stuffed into natural sheep casings, collagen casings, or cellulose casings, and then dried. The restructured jerky with cellulose casing had the lowest water content and the highest protein content, with no significant differences between various formulations. There were no significant differences among all formulations with regard to pH and total microbial counts, and jerky with cellulose casing had the lowest value of water activity. The processing yields ...

2008-01-01

343

Correlated accumulation of anthocyanins and rosmarinic acid in mechanically stressed red cell suspensions of basil (Ocimum basilicum)  

British Library Electronic Table of Contents (United Kingdom)

A red basil cell line (T2b) rich in rosmarinic acid (RA) was selected for the stable production of anthocyanins (ACs) in the dark. Cell suspension cultures were subjected to mechanical stress through increased agitation (switch from 90 to 150rpm) to determine the relationship between AC and RA accumulation. Cell extracts were analyzed by HPLC and LC-MS, and the resulting data were processed with multivariate statistical analysis. MS and MS/MS spectra facilitated the putative annotation of several complex cyanidin-based ACs, which were esterified with coumaric acid and, in some cases, also with malonic acid. It was also possible to identify various RA-related molecules, some caffeic and coumaric acid derivatives and some flavanones. Mechanical stress increased the total AC and RA contents, ...

2011-01-01

344

Comparison of fluid-dynamic modeling of flow with velocity-encoded MR imaging  

International Nuclear Information System (INIS)

This paper develops a fluid dynamic model using finite difference methods characterizing flow in phantoms simulating in vivo conditions and to compare those results with velocity encoded MR images. The phantom consisted of 1-inch (2.5-cm) tubing with semicircular insert and fluid with viscosity, T1, and T2 comparable to blood. Numeric solutions to Navier-Stokes equations for this system were obtained using finite difference methods, with velocity input function of zero at walls and parabolic at both ends. In resulting color raster (CR) images, color temperature represented velocity value. In velocity-encoded MR images acquired under the same flow conditions, phase is proportional to average velocity during application of flow-encoding gradients. Because these gradients are applied along one direction per acquisition, magnitude and direction of velocity are obtained.

1990-11-25

345

Antiferromagnetic Kondo lattice: CePdSi_2  

International Nuclear Information System (INIS)

The compounds CePdSi_2, CeIrSi_2 and CeRhSn_2 have been synthesized and studied by X-ray diffraction, electrical resistivity and magnetic susceptibility. The magnetic susceptibility of CePdSi_2 exhibits two peaks at 6.8 K and 2.5 K, respectively, indicating two antiferromagnetic phase transitions, while that of CeIrSi_2 shows a broad maximum at 150 K, characteristic of valence fluctuating Ce-compounds. CeRhSn_2 remains paramagnetic down to 5 K. The resistivity of CeIrSi_2 exhibits a T"2 dependence at low temperatures, indicating a Fermi-liquid ground state, while those of CePdSi_2 and CeRhSn_2 shows the presence of Kondo and crystal field effects. (orig.).

1996-08-19

346

Ultra high field magnetic resonance imaging  

International Nuclear Information System (INIS)

Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research ...

347

Role of nuclear medicine and magnetic resonance imaging in cardiac diagnostics; Rolle der nuklearmedizinischen Verfahren und der Magnetresonanztomographie in der kardialen Diagnostik  

Energy Technology Data Exchange (ETDEWEB)

Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently seen as gold ...

2003-12-01

348

Perfusion impairments in children with reactive attachment disorder (RAD) on "9"9"mTc-ECD brain SPECT: comparison with MR findings  

International Nuclear Information System (INIS)

This study aimed to reveal that severe disturbance of attachment relationship with primary care-giver can affect functional and anatomical brain development by measuring cerebral perfusion on "9"9"mTc-ECD brain SPECT and correlative MRI. We included 18 children aged 31 to 76 months who met the diagnostic criteria of RAD as defined in DSM-IV and ICD-10 and SSP and CARS. "9"9"mTc-ECD SPECT was performed using CERASPECT. MRI was performed in all patients. SPECT data were visually assessed. 15 of 18 children had abnormal perfusion on SPECT, revealing decreased perfusion of Lt.thalamus (7/15) and Rt.thalamus (3/15), and bilateral thalami (5/15). Perfusion of basal ganglia was decreased in 8 children. Decreased perfusion of Lt. parietal area was seen in 2. Whereas, all patients had normal MR findings. Perfusion abnormalities involving thalamus, BG in most children with RAD were found in this study. These results suggest that brain development of ...

2002-11-15

349

Including the relativistic kinetic energy in a spline-augmented plane-wave band calculation  

International Nuclear Information System (INIS)

The first-order relativistic correction to the kinetic energy of an electron, the mass-velocity term, is not bounded from below. It can, therefore, not be used within a variational framework. To overcome this deficiency we developed a method to include the entire relativistic kinetic energy #sq root#(p"2c"2+m_0"2c"4)-m_0c"2 in a spline-augmented plane-wave band calculation. The first results for silver are quite promising, especially for d and p states: The analysis of the energies of the core states as well as of the valence band structure suggests that the energies of d bands are reproduced within 1 mRy. However, the combination of the relativistic kinetic energy with the Darwin term leads to energies which are too low for s-like valence states by 10 mRy. Therefore, the s and d valence band complex is spread out and the Fermi level is lowered by the same amount as the s states. We expect to overcome these deficiencies in future investigations ...

350

Staging of osteochondritis dissecans of the knee and ankle with MRI. Comparison with conventional radiography and arthroscopy; Die Stadienbestimmung der Osteochondrosis dissecans am Knie- und Sprunggelenk mit der MRT. Vergleich mit konventioneller Radiologie und Arthroskopie  

Energy Technology Data Exchange (ETDEWEB)

A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T{sub 1}- and T{sub 2}-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG) [Deutsch] In einer prospektiven Studie an 50 Patienten mit einer Osteochondrosis ...

1995-07-01

351

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

352

Periosteal Ewing's sarcoma  

International Nuclear Information System (INIS)

Periosteal Ewing's sarcoma is an uncommon, but well documented origin of this malignant condition with radiography signs, different from intramedullary growing tumours. Imaging modalities like CT or MRI supply proof of macroscopically intact endosteal cortical surface and free medullary cavity in long bones affected by this periosteal type of malignancy. Definite confirmation is valid after a careful microscopic investigation of the resected specimen. The prognosis of this type of Ewing's sarcoma may be favourable than that of the central type. Early diagnosis and therapy are thus essential. A clinical survey of six observations is given. (orig.).

353

Magnetic resonance imaging of the pediatric brain  

International Nuclear Information System (INIS)

The atlas presents sequences of MRI sections parallel to the orbito-meatal plane in children from birth through the age of sixteen years. Each child was studied horizontally and sagitally and three-dimensional brain images were reconstructed to facilitate accurate identification of sulci and gyri. The images show crucial aspects of brain development such as the constancy of the brain stem and primitive brain from birth onward; the development of the telencephalon, characterized by deepening of sulci and growth of the cerebral cortex surface; and the different stages of white matter myelinization.

354

MEG studies of human vision: Retinotopic organization of V1  

Energy Technology Data Exchange (ETDEWEB)

A primary goal of noninvasive studies of human vision is to identify and characterize multiple visual areas in the human brain analogous to those identified in studies of nonhuman primates. By combining functional MEG measurements with images of individual anatomy derived from MRI, the authors hope to determine the location and arrangement of multiple visual areas in human cortex and to probe their functional significance. The authors have identified several different visual areas thus far which appear to be topographically organized. This paper focuses on the retinotopic characterization of the primary visual area (V1) in humans.

1993-12-31

355

Inborn Errors of Metabolism Presenting in Childhood  

British Library Electronic Table of Contents (United Kingdom)

Abstract Neurodegenerative and neurometabolic disorders may cause significant morbidity and mortality in children. Imaging is important in early diagnosis of metabolic disorders and in determining the extent of brain injury. Especially after the development of new techniques such as diffusion-weighted magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), neuroimaging plays more important role in the diagnosis and management of these disorders. In these disorders, usually a mutation causes a clinically significant block in one or more metabolic pathways. This blockage usually results in either a deficiency of the product or in an accumulation of substrate with damage induced by either storage or toxicity. The presenting symptoms are usually nonspecific. In some of the ...

2011-01-01

356

A delayed case of renal artery pseudoaneurysm presented with gross hematuria and azotemia in solitary kidney following percutaneous nephrostomy: treated by transcatheter coil embolization.  

Science.gov (United States)

Renal arteriovenous fistula or pseudoaneurysms developing after invasive procedures are either asymptomatic or show only transient symptoms. We describe here a case of symptomatic renal artery pseudoaneurysm that presented with gross hematuria and azotemia. The pseudoaneurysm of renal artery was diagnosed by ultrasonography and abdominal magnetic resonance imaging (MRI), and it was successfully treated by percutaneous transcatheter coil embolization. A high index of suspicion is essential for the early diagnosis and treatment of delayed gross hematuria in patients with history of percutaneous nephrostomy. PMID:17180737

2006-12-19

357

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical application of this ...

2002-03-01

358

The zebrafish heart regenerates after cryoinjury-induced myocardial infarction  

UK PubMed Central (United Kingdom)

BackgroundIn humans, myocardial infarction is characterized by irreversible loss of heart tissue, which becomes replaced with a fibrous scar. By contrast, teleost fish and urodele...Full Text Available

359

The Oxidation Behavior of CoCrAlY, CoCrAl and Yttrium ...  

Science.gov (United States)

... ADD137758. Title : The Oxidation Behavior of CoCrAlY, CoCrAl and Yttrium-Implanted CoCrAl Alloys Compared and Contrasted,. ...

1987-11-01

360

Squamous Cell Carcinoma in South-Eastern Equatorial Rain Forest in Calabar, Nigeria  

UK PubMed Central (United Kingdom)

Background: In North America and Europe, 80% of invasive skin cancers are basal cell carcinoma while 20% are squamous cell carcinoma (SCC). In contrast, African studies reveal a preponderance...Full Text Available

361

STRUCTURE OF THE MACULA UTRICULI WITH SPECIAL REFERENCE TO DIRECTIONAL INTERPLAY OF SENSORY RESPONSES AS REVEALED BY MORPHOLOGICAL POLARIZATION  

UK PubMed Central (United Kingdom)

The anatomy of the labyrinth and the structure of the macula utriculi of the teleost fish (burbot) Lota vulgaris was studied by dissection, phase contrast, and electron microscopy....Full Text Available

1964-08-01

362

Pulmonary toxicity and carcinogenicity of trichloroethylene: species differences and modes of action.  

UK PubMed Central (United Kingdom)

Trichloroethylene (TCE) is both acutely toxic and carcinogenic to the mouse lung following exposure by inhalation. In contrast, it is not carcinogenic in the rat lung and is markedly less toxic following...Full Text Available

2000-05-01

363

Of mice and rats: key species variations in the sexual differentiation of brain and behavior  

UK PubMed Central (United Kingdom)

Mice and rats are important mammalian models in biomedical research. In contrast to other biomedical fields, work on sexual differentiation of brain and behavior has traditionally utilized comparative...Full Text Available

2010-07-01

364

New strain of mouse hepatitis virus as the cause of lethal enteritis in infant mice.  

UK PubMed Central (United Kingdom)

A new strain of mouse hepatitis virus (MHV) was isolated from pooled gut suspensions from an epizootic of lethal enteritis in newborn mice. Negative-contrast electron microscopy showed an abundance...Full Text Available

1979-05-01

365

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

Energy Technology Data Exchange (ETDEWEB)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of ...

1996-06-01

366

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

International Nuclear Information System (INIS)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of ...

367

MR imaging of bone marrow with gradient echo sequences. Pt. 1. Contrast conditions of phase-identical and opposed-phase gradient echo sequences. Kernspintomographische Screeninguntersuchungen des Knochenmarkes mit Gradientenecho-Sequenzen. T. 1. Kontrastverhaeltnisse phasenidentischer und phasenverschobener Gradientenecho-Sequenzen. Untersuchungen von Probanden und pathologisch-anatomischen Praeparaten  

Energy Technology Data Exchange (ETDEWEB)

Anatomical specimens and normal persons were studied by gradient echo MR imaging to determine the influence of different echo times (TE) on bone marrow contrast. First of all, six normal persons were studied to determine specific echo times for in-phase and opposed-phase states. Using different sequences bone marrow contrast in isolated femoral bones was determined and compared to results of pathological exams. Red bone marrow had no signal on opposed-phase images; contrast between red and yellow marrow was higher on opposed-phase than on in-phase images. Bone marrow lesions can be expected to be visualised with high signal on opposed-phase images; this technique should be especially suited for MR imaging of bone marrow. (orig.).

1991-06-01

368

Longitudinally and circumferentially directed movements of the left ventricle studied by cardiovascular magnetic resonance phase contrast velocity mapping  

UK PubMed Central (United Kingdom)

ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available

369

Kinetic Complexity of the Global Response to Glucocorticoid Receptor Action  

UK PubMed Central (United Kingdom)

We have characterized the kinetic response of gene targets throughout the murine genome to transcriptional modulation by the glucocorticoid receptor (GR). In contrast to a model in which multiple genes...Full Text Available

2009-04-01

370

Is hepatotropic contrast enhanced MR a more effective method in differential diagnosis of hemangioma than multi-phase CT and unenhanced MR?  

UK PubMed Central (United Kingdom)

BackgroundCavernous hemangiomas are the most frequent neoplasms of the liver and in routine clinical practice they often need to be differentiated from malignant tumors and other...Full Text Available

371

Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol  

International Nuclear Information System (INIS)

Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both contrast agents were ...

1999-09-01

372

Increased expression of cytosolic chaperonin CCT in human hepatocellular and colonic carcinoma  

Science.gov (United States)

... protein is abundant in cytosolic portions of malignant epithelial tissue (Fig. 3A). In contrast, the degree of CCTβ staining in normal epithelial tissue (Fig. 3B) or connective tissues was much weaker ......

373

Expansions, contractions, and fragility of the spinocerebellar ataxia type 10 pentanucleotide repeat in yeast  

UK PubMed Central (United Kingdom)

Spinocerebellar ataxia 10 (SCA10) is an autosomal dominant disease caused by large-scale expansions of the (ATTCT)n repeat within an intron of the human ATXN10 gene. In contrast...Full Text Available

2011-02-15

374

Evaluation of Tumor Micro-Environment in an Animal Model using a Nanoparticle Contrast Agent in Computed Tomography Imaging  

UK PubMed Central (United Kingdom)

RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available

2011-01-01

375

Evaluation of Oral Administration of Adenine to Dogs and Primates.  

Science.gov (United States)

Little change was observed in primates fed 75 mg/kg adenine over the four-week period. Minimal tissue pathology was encountered upon completion of the study. In contrast to earlier studies in which oral feeding of adenine to dogs caused severe symptoms, a...

1974-01-01

376

Enhanced CT and CT virtual endoscopy in diagnosis of heterotopic pancreas  

UK PubMed Central (United Kingdom)

AIM: To improve the diagnosis of heterotopic pancreas by the use of contrast-enhanced computed tomography (CT) imaging and CT virtual endoscopy (CTVE).METHODS: A total of six patients with heterotopic...Full Text Available

2011-09-07

377

Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis  

UK PubMed Central (United Kingdom)

Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available

2008-01-01

378

Dual Energy and Low kVp CT in the Abdomen  

UK PubMed Central (United Kingdom)

Low kVp settings provide high conspicuity of contrast materials at CT but may result in high image noise, particularly in larger patients. Material decomposition at dual energy CT can differentiate...Full Text Available

2009-07-01

379

Dimeric subunit stoichiometry of the human voltage-dependent proton channel Hv1  

UK PubMed Central (United Kingdom)

In voltage-gated Na+, K+, and Ca2+ channels, four voltage-sensor domains operate on a central pore domain in response to membrane voltage. In contrast, the voltage-gated...Full Text Available

2008-06-03

380

Differing in vitro Survival Dependency of Mouse and Rat NG2+ Oligodendroglial Progenitor Cells  

UK PubMed Central (United Kingdom)

NG2 chondroitin sulfate proteoglycan is a surface marker of oligodendroglial progenitor cells (OPCs) in various species. In contrast to well-studied rat OPCs, however, we found that purified...Full Text Available

2010-04-01

381

Development of melanopsin-based irradiance detecting circuitry  

UK PubMed Central (United Kingdom)

BackgroundMost retinal ganglion cells (RGCs) convey contrast and motion information to visual brain centers. Approximately 2% of RGCs are intrinsically photosensitive (ipRGCs), express...Full Text Available

382

Cross-sectional Specimen Preparation and Observation of a Plasma Sprayed Coating Using a Focused Ion Beam/Transmission Electron Microscopy System.  

Science.gov (United States)

A focused ion beam (FIB) technique was applied to cross-sectional specimen preparation to observe an interface between a plasma sprayed coating and an aluminum (Al) substrate by transmission electron microscopy (TEM). The surface of the sprayed coating film has a roughness of several tens of microns. Sputter rates for the coating film and the substrate are greatly different. The rough surface and the difference in sputter rate cause problems in making TEM specimens with smooth side walls. The top surface of the coating film was planerized by the FIB before fabricating the TEM specimen. The interfaces were investigated by TEM and energy-dispersive X-ray (EDX) analysis. The TEM observation revealed that there is a 10 nm thick amorphous layer at the interface between the coating film and substrate. The coating film consists of two kinds of sublayers with bright and dark contrast. The bright contrast sublayers were amorphous layers with thickness ...

2000-05-01

383

Contrasting Population Structures of the Genes Encoding Ten Leading Vaccine-Candidate Antigens of the Human Malaria Parasite, Plasmodium falciparum  

UK PubMed Central (United Kingdom)

The extensive diversity of Plasmodium falciparum antigens is a major obstacle to a broadly effective malaria vaccine but population genetics has rarely been used to guide vaccine design....Full Text Available

384

Comparing and Contrasting the Roles of AMPK and SIRT1 in Metabolic Tissues  

UK PubMed Central (United Kingdom)

The ability to adapt and respond to nutrients is an ancient cellular function, conserved from unicellular to the most complex multicellular organisms, including mammals. Mammals adapt to changes...Full Text Available

2008-12-01

385

Comparative aspects of cortical neurogenesis in vertebrates  

UK PubMed Central (United Kingdom)

The mammalian neocortex consists of six layers. By contrast, the reptilian and avian cortices have only three, which are believed to be equivalent to layers I, V and VI of mammals. In mammals, the majority...Full Text Available

2007-08-01

386

Common genetic variation and susceptibility to partial epilepsies: a genome-wide association study  

UK PubMed Central (United Kingdom)

Partial epilepsies have a substantial heritability. However, the actual genetic causes are largely unknown. In contrast to many other common diseases for which genetic association-studies have successfully...Full Text Available

2010-07-01

387

Colour television, an imitation of the human visual system.  

UK PubMed Central (United Kingdom)

Colour television is examined as an attempt to imitate the human visual system in image formation, spectral sensitivities, adaptation, contrast effects, signal processing, signal modulation, signal...Full Text Available

1975-07-01

388

Bimodal MR-PET agent for quantitative pH imaging  

UK PubMed Central (United Kingdom)

Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available

2010-03-22

389

Alteration of the chemical environment disrupts communication in a freshwater fish  

UK PubMed Central (United Kingdom)

It is well established that changes to the chemical environment can impair development, physiology and reproductive biology; by contrast, impacts on communication have not been widely reported. This...Full Text Available

2006-05-22

390

Age-Related Deterioration of Rod Vision in Mice  

UK PubMed Central (United Kingdom)

Even in healthy individuals, aging leads to deterioration in visual acuity, contrast sensitivity, visual field, and dark adaptation. Little is known about the neural mechanisms that drive the...Full Text Available

2010-08-18

391

Volumetric quantification of brain development using MRI  

International Nuclear Information System (INIS)

We devised a three-dimensional method for estimation of cerebral development and myelination which measures cerebral volume using MRI. Accuracy of the system was estimated using cadaver brains. The mean percentage error in the calculated volumes compared with the real volumes was 2.33 %, range 0.00-5.33 %. We applied the method to the volume of both cerebral hemispheres (CH), basal ganglia, thalamus and internal capsule (BT), and myelinated white matter (WM) in 44 neurologically normal individuals (4 months to 28 years of age), 13 patients with spastic motor disturbances (2-25 years of age), and 9 patients with athetotic motor disturbances (2-23 years of age). In the neurologically normal cases, the volumes of CH, BT and WM increased with age; the volume of MW more slowly than that of CH. In cases with spastic motor disturbances, the volumes of CH, BT and WM were between -1.4 and 3.5 SD, -1.0 and -3.5 SD, and 0.0 and -5.2 SD respectively, of those of ...

392

The value of high-resolution MR-imaging for the staging of malignant lesions of tongue, pharynx and larynx; Klinische Wertigkeit der hochaufloesenden Magnetresonanztomographie beim Staging von Tumoren der Mundhoehle, des Pharynx und des Larynx  

Energy Technology Data Exchange (ETDEWEB)

In a prospective study 102 patients with malignant tumors of the tongue, oropharynx, hypopharynx, and larynx were staged by means of MRI. Special attention was directed at those tumour extensions that could influence the treatment strategy. The MR findings were correlated with the results of palpation, endoscopy, ultrasound, computerised tomography and histopathological findings. MRI showed a good delineation of pT{sub 2} to pT{sub 4} tumours. However, visualisation of small tumours in the soft palate, the tonsils, the pyriform sinuses and vocal cords was difficult. In conclusion our results suggest that in addition to endoscopy MRI is a valuable tool for the examination of tumours of tongue, oropharynx, hypopharynx and larynx. (orig.) [Deutsch] In einer prospektiven Studie wurden 102 Patienten mit malignen Tumoren der Mundhoehle, des Oro- und Hypopharynx sowie des Larynx mit der Mgnetresonanztomographie (MRT) untersucht, ...

1994-02-01

393

Injured lateral ankle ligaments: technique and assessment of MRI; Verletzungen des Aussenbandapparates am oberen Sprunggelenk: Untersuchungstechnik und Nachweis mittels MRT  

Energy Technology Data Exchange (ETDEWEB)

56 patients with the clinical diagnosis of sprained ankles were investigated. Evaluation of the anterior (AFTL) and posterior fibulotalar ligament (PFTL) was performed with the foot in dorsiflexion (20 ) and of the fibulo calcanear ligament (FCL) in plantarflexion (45 ). Axial T{sub 1}w-SE and T{sub 2}w-TSE images were obtained. Full-length visualisation of ligmaments in one slice and the extent of injury were evaluated. 12 ankle injuries were confirmed by operation. With MRI full-length visualisation of lateral ankle ligaments was possible in 86%. A partial/complete rupture of the AFTL was noticed in 33/64% and of the FCI in 29/39%, and of the PFTL in 27/5%. Sensitivity/specificity of MRI when compared to surgery was 100/100% for injuries of the AFTL, 64/100% for the FCL, and 33/78% for the PFTL. (orig./MG) [Deutsch] 56 Patienten wurden mit der klinischen Diagnose einer frischen Supinationsverletzung des oberen Sprunggelenkes untersucht. Das ...

1996-03-01

394

Hilar cholangiocarcinoma: MR correlation with surgical and histological findings  

International Nuclear Information System (INIS)

Aim: To evaluate magnetic resonance cholangiography (MRC) with high-resolution dynamic gadolinium-enhanced magnetic resonance imaging (MRI) in determining the imaging features of hilar cholangiocarcinoma that relate to tumour extent and influence resectability. Materials and methods: Twenty-six patients that underwent resection were reviewed. Tumour location and extent, lobar atrophy, the degree of portal vein and hepatic artery involvement were recorded. The findings were correlated with surgical and histopathological findings. Results: Biliary assessment was concordant in 14 and discordant in eight of 14 stented and four of 12 non-stented patients. In 63/82 veins and 43/74 arteries results were fully concordant. The mean sensitivity, specificity, positive and negative predictive values (PPV, NPV) in predicting involvement of the main portal vein (MPV) at surgery were 83.3, 100, 100, and 92.5%; of the left main branch of the portal vein (LPV) were 100, 91.6, 93.3, ...

2010-10-01

395

Frontopolar and anterior temporal cortex activation in a moral judgment task. Preliminary functional MRI results in normal subjects  

International Nuclear Information System (INIS)

The objective was to study the brain areas which are activated when normal subjects make moral judgments. Ten normal adults underwent BOLD functional magnetic resonance imaging (fMRI) during the auditory presentation of sentences that they were instructed to silently judge as either 'right' or 'wrong'. Half of the sentences had an explicit moral content ('We break the law when necessary'), the other half comprised factual statements devoid of moral connotation ('Stones are made of water'). After scanning, each subject rated the moral content, emotional valence, and judgment difficulty of each sentence on Likert-like scales. To exclude the effect of emotion on the activation results, individual responses were hemo dynamically modeled for event-related f MRI analysis. The general linear model was used to evaluate the brain areas activated by moral judgment. Regions activated during moral judgment included the frontopolar cortex (FPC), medial ...

2001-09-01

396

Cerebral angiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).

1985-01-01

397

Results of electron beam therapy using intra-oral cone for carcinoma of the oral tongue  

Energy Technology Data Exchange (ETDEWEB)

Retrospective analyses were performed to evaluate the therapeutic efficacy of intra-oral cone (IOC) radiation therapy for carcinoma of the oral tongue, especially about its faculty of local control and complications. Thirty-nine patients with squamous cell carcinoma of the oral tongue were treated with IOC radiation therapy alone or in combination with external irradiation. IOC radiation therapy was given not only for T1 and T2, but also for T3 tumors. Hypofractionation was used for IOC radiation therapy. The 2 year local control rates, including surgical salvage, for T1, T2, T3 and T4 were 100%, 73.3%, 40% and 0%, respectively. The 5 year actuarial survival rates for Stage I, II, III and IV were 100%, 65.3%, 35.4% and 0%, respectively. The incidences of radiation complications, i.e. soft tissue ulceration and osteoradionecrosis, were 42.9% and 2.9%, respectively. It is suggested that relatively high ...

1992-07-01

398

Molecular insights from bariatric surgery.  

Science.gov (United States)

Bariatric surgical procedures have become important therapeutic options for treatment of morbid obesity in both adults and adolescents co-morbidities of obesity such as glucose intolerance, type 2 diabetes (T2DM), metabolic syndrome, steatohepatitis, hyperlipidemia and cardiovascular disease. These co-morbidities of obesity have significant impacts on the overall quality of life of the individual and our society at large. Roux-en-Y gastric bypass (RYGB) and the relatively newer procedures of gastric banding (GB) and vertical sleeve gastrectomy (VSG) have proven to be efficacious in achieving rapid weight loss and reversing the comorbidities of obesity. Unfortunately, bariatric procedures are not without risks including micronutrient deficiency, failure to maintain lost weight, and mortality. Further, the resolution of T2DM has long been understood to precede weight loss, and this finding provides ...

2011-09-01

399

Soft tissue manifestations of early rheumatic disease. Imaging with MRI; Fruehmanifestationen rheumatischer Gelenkerkrankungen an den Weichgewebestrukturen der Hand. Nachweis mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). Only dactylitis ...

2006-08-15

400

Nephrogenic systemic fibrosis after application of gadolinium-based contrast agents - a status paper; Nephrogene systemische Fibrose nach Anwendung gadoliniumhaltiger Kontrastmittel - ein Statuspapier zum aktuellen Stand des Wissens  

Energy Technology Data Exchange (ETDEWEB)

Recently the association of a rare disease named ''nephrogenic systemic fibrosis'' (NSF) with the administration of gadolinium-containing contrast media, especially gadodiamide (Omniscan, GE-Healthcare), was described. NSF is a scleroderma-like disease characterised by widespread tissue fibrosis. Until now, NSF cases were observed only in patients with kidney disease. Almost all patients were suffering from chronic renal insufficiency, 90 % of them required renal replacement therapy. The true incidence of the disease is unknown. First retrospective analyses of selected collectives of patients with end-stage renal disease showed 2 - 5 % cases of NSF after administration of Gadolinium-containing contrast agents with an odds ratio of 20 - 50 in comparison to non-exposed controls. NSF is a serious adverse reaction, which may result in severe disabilities and even death. Therefore all radiologists applying ...

2007-06-15

401

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...

1989-06-01

402

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

International Nuclear Information System (INIS)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...

1989-01-01

403

A simplified method of opacifying and mixing acrylic cement for percutaneous vertebroplasty: a clinical and in vitro study.  

Science.gov (United States)

The objective of this study was to simplify the opacifying mixing process of the bone cement and contrast used for percutaneous vertebroplasty (PVP). We performed a biomechanical study of polymethyl methacrylate (PMMA) (Corinplast 3) using three different mixtures of PMMA, monomer, and contrast: group I, 2:1; group II, 3:2; group III, 3:2:1 ratio of powder/monomer/iodinated contrast (Omnipaque). In vitro biomechanical testing of ultimate compressive strength was carried out in all samples. Following the conclusion of a proper bone cement mixture regimen drawn from the in vitro study, PVP was performed in 125 patients: 58 with cancer, 12 with hemangioma, and 54 with osteoporotic fracture. The ultimate compressive strength in group III was decreased by 38% compared to groups II and I. Proper fluoroscopic visualization was achieved in all PVP procedures using this mixture. There were no major complications associated with ...

404

A Simplified Method of Opacifying and Mixing Acrylic Cement for Percutaneous Vertebroplasty: A Clinical and In Vitro Study  

Science.gov (United States)

The objective of this study was to simplify the opacifying mixing process of the bone cement and contrast used for percutaneous vertebroplasty (PVP). We performed a biomechanical study of polymethyl methacrylate (PMMA) (Corinplast{sup TM} 3) using three different mixtures of PMMA, monomer, and contrast: group I, 2:1; group II, 3:2; group III, 3:2:1 ratio of powder/monomer/iodinated contrast (Omnipaque). In vitro biomechanical testing of ultimate compressive strength was carried out in all samples. Following the conclusion of a proper bone cement mixture regimen drawn from the in vitro study, PVP was performed in 125 patients: 58 with cancer, 12 with hemangioma, and 54 with osteoporotic fracture. The ultimate compressive strength in group III was decreased by 38% compared to groups II and I. Proper fluoroscopic visualization was achieved in all PVP procedures using this mixture. There were no major complications associated ...

2005-06-15

405

Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals generated by multiple repetition of this process of excitation of nuclei and their return to ...

1999-10-01

406

MRI-based N-staging in esophageal cancer; N-Staging des Oesophaguskarzinoms mittels MRT unter Verwendung von artefaktreduzierenden LOTA-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with ...

2002-10-01

407

Inflammatory spine disease as a cause of back pain; Entzuendliche Wirbelsaeulenerkrankungen als Ursache fuer Rueckenschmerzen  

Energy Technology Data Exchange (ETDEWEB)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-{alpha} antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-{alpha} antagonists is based on clinical and laboratory criteria, and signs of inflammation in MRI. ...

2006-06-15

408

Comparison of histological findings and parathyroid scintigraphy in hemodialysis patients with secondary hyperparathyroid glands  

International Nuclear Information System (INIS)

The objective of this study was to determine the usefulness of parathyroid scintigraphy in histological estimation for secondary hyperparathyroidism (2HPT) using Tc-99m sestamibi or Tc-99m tetrofosmin. Tc-99m sestamibi (MIBI) and Tc-99m tetrofosmin (Tetro) parathyroid imaging following double-phase study, magnetic resonance imaging (MRI), and ultrasound were performed on 14 patients with 2HPT. All patients underwent parathyroidectomy. The uptake of two tracers in parathyroid areas was compared with the histopathologic findings. Forty-nine parathyroid glands were surgically explored and histologically proven to be hyperplastic. Of these, 42 were diagnosed with nodular type (N-type) hyperplasia, and 7 with diffuse type (D-type) hyperplasia. MIBI and Tetro parathyroid imagings detected 34 and 35 parathyroid glands, respectively. The sensitivity of MIBI was determined to be 76.2% (32/42) for N-type, and 28.6% (2/7) for D-type. The sensitivity of Tetro was determined to ...

2005-04-01

409

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast images are extracted from experimental projection images by an ...

2006-08-01

410

Lasing efficiency and tuning range of a dynamic distributed-feedback laser  

Energy Technology Data Exchange (ETDEWEB)

The effects of the contrast of the pump field interference pattern, that is, the effectiveness of the dynamic amplitude-phase grid, and various optical arrangements on the lasing efficiency and tuning range of a dynamic distributed-feedback dye laser are investigated. It is shown that the proper choice of prism apex angle, prism material and dye solvent in a laser in the range 400-1000 microns pumped by two beams of different intensity directed through the congruent sides of an isosceles prism in contact with the active medium solution on its third side can lead to optical losses of less than 2% from the boundaries of the prism. Measurements of polymethine dye laser efficiency and tuning range as a function of the relative intensity of the two ruby-laser pump beams reveals that as the contrast of the pump beam interference pattern decreases, the tuning range remains practically constant and the efficiency increases in the nonlinear (saturation) ...

1980-08-01

411

Fluorescence based molecular in vivo imaging; Fluoreszenzgestuetzte molekulare Bildgebung in vivo  

Energy Technology Data Exchange (ETDEWEB)

Molecular imaging represents a modern research area that allows the in vivo study of molecular biological process kinetics using appropriate probes and visualization methods. This methodology may be defined- apart from the contrast media injection - as non-abrasive. In order to reach an in vivo molecular process imaging as accurate as possible the effects of the used probes on the biological should not be too large. The contrast media as important part of the molecular imaging can significantly contribute to the understanding of molecular processes and to the development of tailored diagnostics and therapy. Since more than 15 years PTB is developing optic imaging systems that may be used for fluorescence based visualization of tissue phantoms, small animal models and the localization of tumors and their predecessors, and for the early recognition of inflammatory processes in clinical trials. Cellular changes occur during many diseases, thus the ...

2008-12-15

412

Evaluation of selective alveolo-bronchography with Fuji computed radiography and x-ray CT  

International Nuclear Information System (INIS)

Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using ...

1986-01-01

413

Evaluation of computer-aided detection of lesions in mammograms obtained with a digital phase-contrast mammography system  

Energy Technology Data Exchange (ETDEWEB)

A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-{mu}m-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM system is a promising approach for the detection of breast cancer in its ...

2009-12-15

414

Transplantation of progenitor cells and regeneration enhancement in acute myocardial infarction (TOPCARE-AMI): final 5-year results suggest long-term safety and efficacy  

British Library Electronic Table of Contents (United Kingdom)

Background Limited data is available for investigating the long-term safety and effects of intracoronary progenitor cell therapy in patients with acute myocardial infarction (AMI). Objective To assess the clinical course, NT-proBNP and MRI data as objective markers of cardiac function of the TOPCARE-AMI patients at 5-year follow-up. Design The TOPCARE-AMI trial was the first randomized study investigating the effects of intracoronary infusion of circulating (CPC) or bone marrow-derived progenitor cells (BMC) in 59 patients with successfully reperfused AMI. Results Five-year follow-up data were completed in 55 patients, 3 patients were lost to follow-up. None of the patients showed any signs of intramyocardial calcification or tumors at 5?years. One patient died during the initial hospitali...

2011-01-01

415

The usefulness of CBF brain SPECT in forensic medicine: the civil law codes cases. A description of four cases  

International Nuclear Information System (INIS)

The aim of this report was to assess the usefulness of cerebral blood flow (CBF) scanning utilising the SPECT technique in forensic medicine cases in the area of civil law cases. CBF SPECT scanning was performed in four patients utilising "9"9"mTc-ECD and a triple-head gammacamera. In the analysis both the asymmetry index and cerebellar normalisation were applied. Reference values were obtained by studying 30 healthy volunteers. In those cases CBF SPECT scanning played an important role in forensic argument. It influenced the sentence and the amount of financial compensation. CBF SPECT scanning may provide valuable information in forensic medicine argument in civil law cases, but only when taken together with psychometric tests and other neuroimaging methods (CT, MRI). The value of CBF SPECT scanning alone may be limited in judicial proceedings. (author)

416

The similarity of twin brains  

International Nuclear Information System (INIS)

To test the assumption underlying every morphometric twin study that the brains of monozygotic twins are almost identical. Methods: High resolution MRI of the neurocranium of 26 monozygotic twin pairs were acquired and the volumes of 36 cerebral structures were measured. The same twins served as control group after rear-ranging them into non-related pairs of same sex and matching them for age, body height and body weight. Results: For most of the examined structures the correlations within the twins were significant (R = 0,97-0,59). Except for total forebrain volume the controls showed no significant similarity. Conclusions: For almost every measured cerebral structure the assumption, that significant similarities exist between healthy monozygotic twins is correct. Therefore discordant monozygotic twins represent an excellent sample when investigating cerebral correlates of neurologic and psychiatric disorders. (orig.)

2001-06-01

417

The effects of physical activity, education, and body mass index on the aging brain  

British Library Electronic Table of Contents (United Kingdom)

Abstract Normal human aging is accompanied by progressive brain tissue loss and cognitive decline; however, several factors are thought to influence brain aging. We applied tensor-based morphometry to high-resolution brain MRI scans to determine whether educational level or physical activity was associated with brain tissue volumes in the elderly, particularly in regions susceptible to age-related atrophy. We mapped the 3D profile of brain volume differences in 226 healthy elderly subjects (130F/96M; 77.9 3.6 SD years) from the Cardiovascular Health Study-Cognition Study. Statistical maps revealed the 3D profile of brain regions whose volumes were associated with educational level and physical activity (based on leisure-time energy expenditure). After controlling for age, sex, and physical...

2011-01-01

418

Testosterone reduces amygdalaorbitofrontal cortex coupling  

British Library Electronic Table of Contents (United Kingdom)

Testosterone influences various aspects of affective behavior, which is mediated by different brain regions within the emotion circuitry. Previous neuroimaging studies have demonstrated that testosterone increases neural activity in the amygdala. To investigate whether this could be due to altered regulation of amygdala functioning which is thought to be mediated by the prefrontal cortex, we studied the effects of exogenous testosterone on the interaction between the amygdala and other brain regions. Healthy middle-aged women received a single nasal testosterone dose in a randomized, placebo-controlled, crossover manner, and performed an emotional face matching task while their brain activity was measured with functional MRI. The results show that testosterone rapidly reduced functional co...

2010-01-01

419

Symptomatic hepatic cyst in a child: treatment with single-shot injection of tetracycline hydrochloride  

Energy Technology Data Exchange (ETDEWEB)

The prevalence of hepatic cysts is 0.1% to 0.5% based on autopsy studies, and 2.5% based on US examinations. Percutaneous therapies are a new alternative to surgery. They include simple percutaneous aspiration, catheter drainage alone, and catheter drainage with sclerotherapy. We present an 11-year-old boy admitted to hospital because of abdominal pain. A diagnosis of simple hepatic cyst was made, which was treated with aspiration and tetracycline hydrochloride solution (5%) injection into the cystic cavity. Complete regression was seen on US and MRI examination at 3 months, with total collapse and deflation of the cyst. The cyst regressed totally, leaving a hyperechoic linear scar on US examination at 1 year. On the basis of the clinical and imaging results obtained, percutaneous sclerotherapy of hepatic cysts can be recommended as the treatment of choice and as a valid alternative to laparoscopy in children. (orig.)

2009-10-15

420

Role of death receptor, mitochondrial and endoplasmic reticulum pathways in different stages of degenerative human lumbar disc  

British Library Electronic Table of Contents (United Kingdom)

Intervertebral disc (IVD) cell apoptosis has been suggested to play an important role in promoting the degeneration process. It has been demonstrated that IVD cell apoptosis occurs through either death receptor, mitochondrial or endoplasmic reticulum (ER) pathway. Our study aimed to explore the relationship among these three pathways and grade of IVD degeneration (IVDD). IVDs were collected from patients with lumbar fracture, vertebral tumor, disc herniation or spondylolisthesis. IVDs were distinguished by MRI and histomorphological examination, cell apoptosis was detected by TUNEL staining. Biomarkers of these three apoptosis pathways were detected by RT-PCR and Western blot. Furthermore, the correlation between apoptosis pathways biomarkers and disc pathology were analyzed. Nucleus pulpo...

2011-01-01

421

Primary cutaneous Ewing's sarcoma/primitive neuroectodermal tumor manifesting numerous small and huge ulcerated masses: its complete remission by chemotherapy and magnetic resonance imaging findings  

International Nuclear Information System (INIS)

Extraskeletal Ewing's sarcoma (ES) and primitive neuroectodermal tumor (PNET) are widely regarded as clinically and histologically identical tumors which consist of small blue round cells. Extraskeletal ESs/PNETs usually occur in the deep soft tissues of the paraspinal region, chest wall, or lower extremities. However, superficially located cases, so-called cutaneous ESs/PNETs, are exceedingly rare, and the vast majority of the reported cases present as a single small mass. We present magnetic resonance imaging (MRI) findings and clinical course of a unique case of primary cutaneous ES/PNET presenting as numerous huge masses with severe ulceration on them. (orig.)

2010-06-01

422

Moral Judgments Recruit Domain-General Valuation Mechanisms to Integrate Representations of Probability and Magnitude  

British Library Electronic Table of Contents (United Kingdom)

Summary Many important moral decisions, particularly at the policy level, require the evaluation of choices involving outcomes of variable magnitude and probability. Many economic decisions involve the same problem. It is not known whether and to what extent these structurally isomorphic decisions rely on common neural mechanisms. Subjects undergoing fMRI evaluated the moral acceptability of sacrificing a single life to save a larger group of variable size and probability of dying without action. Paralleling research on economic decision making, the ventromedial prefrontal cortex and ventral striatum were specifically sensitive to the "expected moral value" of actions, i.e., the expected number of lives lost/saved. Likewise, the right anterior insula was specifically sensitive to outcome p...

2010-01-01

423

Magnetic resonance imaging (MRI) of the central nervous system in long-term manganese dioxide (MnO{sub 2}) exposed workers; Magnetresonanztomographie des Gehirns bei Beschaeftigten mit chronischer beruflicher Mangandioxid-Exposition  

Energy Technology Data Exchange (ETDEWEB)

Aim: Changes within the brain detected by MRI after chronic manganese poisoning raised the question whether morphological changes of the basal ganglia, particularly of the globus pallidus, could be detected after chronic occupational exposure to manganese dioxide. Results: No cases of parkinsonism were detected in clinical examinations or by other means. The mean manganese concentration in blood was 12 {mu}g/l (range: 3.9-23.3 {mu}g/l). In comparison to the upper reference value of 10 {mu}g/l, 42 workers (56%) had a higher body burden. A significant positive correlation between manganese levels in blood and the PI (indicated by T{sub 1}-shortening) was observed as well as between the CBI and workplace-specific exposure. Brain atrophy was not detected in any of the observed cases. Conclusions: Long-term exposure to manganese dioxide dust correlates with the Pallidum-Index in MRI scans. Although the MRI findings have no ...

2000-06-01

424

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image nonuniformity ...

2001-03-01

425

MR-based volumetric analysis of small tumor volumes: accuracy of phantom examinations of simulated eye tumors; Evaluierung der MR-Volumetrie kleiner Volumina am Beispiel von Augentumoren mittels Phantomuntersuchungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The determination of tumor volume in ocular tumors is very important for the planning and success of radiation therapy. This study uses an animal model to evaluate the accuracy of MR-based volumetry of ocular tumors. Materials and methods: In a total of 25 porcine eyes obtained from the slaughterhouse, ocular tumors were produced by injecting a mixture of hand creme and Gd-DTPA under ophthalmoscopic guidance. The injected volume varied between 0.05 ml and 2.7 ml. The eyes were examined with a 1.5 Tesla scanner and a 4 cm circular surface coil especially developed for ocular MRI. After data transfer to a separate workstation, volumetric analysis was carried out by three independent radiologists using semiautomated software. The determined volume was compared with the injected volume. Results: Of the 25 prepared porcine eyes, 23 were suitable for volumetric analysis. The injection of the mixture of hand creme and GD-DTPA produced two different types of ...

2003-07-01

426

Evaluation of cost effectiveness for conservative and active management strategies for acoustic neuroma  

British Library Electronic Table of Contents (United Kingdom)

Clin. Otolaryngol. 2009, 34, 438-446. Objective: To determine whether economic costs associated with a conservative management strategy for unilateral acoustic neuroma offer an economic advantage over active management options. Design: Cost and sensitivity analysis on a prospective cohort. Setting: Single centre study within a tertiary referral centre in Toronto, Canada. Participants: 72 patients (32 males, 40 females) aged 36 to 78 years with unilateral acoustic neuroma were assigned initially to a conservative management strategy. Entry criteria were small tumour size (less than 15mm in the cerebellopontine angle), patient preference and/or significant co-morbidity. Interventions: MRI scanning was performed every 6 months for the first year, annually subsequently and then every 2-3 years...

2009-01-01

427

Episodic Future Thinking Reduces Reward Delay Discounting through an Enhancement of Prefrontal-Mediotemporal Interactions  

British Library Electronic Table of Contents (United Kingdom)

Summary Humans discount the value of future rewards over time. Here we show using functional magnetic resonance imaging (fMRI) and neural coupling analyses that episodic future thinking reduces the rate of delay discounting through a modulation of neural decision-making and episodic future thinking networks. In addition to a standard control condition, real subject-specific episodic event cues were presented during a delay discounting task. Spontaneous episodic imagery during cue processing predicted how much subjects changed their preferences toward more future-minded choice behavior. Neural valuation signals in the anterior cingulate cortex and functional coupling of this region with hippocampus and amygdala predicted the degree to which future thinking modulated individual preference fu...

2010-01-01

428

Blood flow quantification with MRI using the phase mapping method. Moeglichkeiten und Grenzen der Blutflussquantifizierung peripherer arterieller Gefaesse mit der MRT unter Anwendung des Phase-Mapping-Verfahrens  

Energy Technology Data Exchange (ETDEWEB)

MRT is able to demonstrate arteries while MR angiography can quantify blood flow by a non-invasive method. In the present paper blood flow measurements were carried out in four selected cases on the basis of phase mapping. In 3 patients with lesions in the pelvis or thigh, angiography was performed in order to localise the stenosis or occlusion and this was followed by qantitative blood flow measurements. The results showed that angiography may not always provide all necessary information concerning a haemodynamically significant stenosis. The method may also be used for quantifying blood flow in the renal arteries and that it has significant advantages over the colour Doppler method. (orig.).

1992-08-01

429

The diagnosis of inflammatory muscular and vascular conditions using MRT with STIR sequences  

International Nuclear Information System (INIS)

The role of MRT in the prebiopsy diagnosis of muscular and vascular inflammatory conditions was evaluated prospectively and an optimal method of examination was investigated. 92 patients with a suspected diagnosis of myositis (60 cases) or vasculitis (32 cases) were examined, in each case two extremities were studied using transverse T_1 and T_2 weighted SE sequences and double echo STIR sequences on a 0.5 Tesla (56 patients) or 1.5 Tesla magnet (36 patients; T5/S15 Gyroscan, Philips). The site of the biopsy depended on the MRT findings. In 41 patients the suspected diagnosis was confirmed histologically, in two patients an infective myositis was diagnosed on clinical grounds despite negative histology. MRT demonstrated muscle oedema in 86% of patients. There were negative findings after immuno-suppressive therapy (two patients), in focal myositis (3 out of 4 patients) and in one of 7 patients with untreated vasculitis. Amongst 49 patients in ...

430

Relatively large theta13 and nearly maximal theta23 from the approximate S3 symmetry of lepton mass matrices  

CERN Document Server

We apply the permutation symmetry S3 to both charged-lepton and neutrino mass matrices, and suggest a useful symmetry-breaking scheme, in which the flavor symmetry is explicitly broken down via S3 -> Z3 -> nothing in the charged-lepton sector and via S3 -> Z2 -> nothing in the neutrino sector. Such a two-stage breaking scenario is reasonable in the sense that both Z3 and Z2 are the subgroups of S3, while Z3 and Z2 only have a trivial subgroup. In this scenario, we can naturally obtain a relatively large value of the smallest neutrino mixing angle, e.g., theta13 ~ 9 degrees, which is compatible with the recent result from T2K experiment and will be precisely measured in the ongoing Double Chooz and Daya Bay reactor neutrino experiments. Moreover, the maximal atmospheric mixing angle theta23 ~ 45 degrees can also be obtained while the best-fit value of solar mixing angle theta12 ~ 34 degrees is assumed, which cannot be achieved in ...

2011-01-01

431

Radiation damage studies on CrO_4"2"- doped alums  

International Nuclear Information System (INIS)

Radiation damage studies have been carried out on undoped and CrO_4"2"- doped potassium and ammonium alums. The optical absorption bands observed around 27100 and 36500 cm"-"1 before irradiation have been attributed to the transitions t_1 #-># e and t_1 #-># t_2, on the basis of Ball-hausen and Liehr scheme. On prolonged X-irradiation, these bands disappear in both the alums and three new bands seem to grow in ammonium alum while only two new bands could be seen in potassium alum. EPR studies at RT reveal that there are two lines at g = 2.004 and g = 2.010 in ammonium alum and only one line at g = 2.004 in potassium alum. Besides these two nearly isotropic lines, there is a set of lines around g = 1.95 in both the alums. Correlating the optical and EPR studies it is concluded that SO_3"- and O_3"- centres have formed on X-irradiation in ammonium alum while only SO_3"- seems to have formed in potassium alum. The most important feature is ...

432

Primary adenocarcinoma of the urinary bladder: value of cell cycle biomarkers.  

Science.gov (United States)

Primary adenocarcinomas of the urinary bladder are uncommon, and the molecular pathways are currently not well defined. In this study, we assessed the association between biologic markers and clinicopathologic characteristics in a cohort of 21 patients with primary urinary bladder adenocarcinoma. Immunohistochemical staining for cell cycle-specific markers, including p53, p21, p27, Ki-67, and cyclin E, were performed on sections of a tissue microarray construct. The tumors were high grade in 12 (57%) and pT2 or higher in 18 (86%); lymph nodes were involved in 6 cases (29%); and there was pathologic evidence of schistosomiasis in 14 (67%). The best prognostic combination of markers was combined alterations in p27 and Ki-67 and was associated with stage (P = .012), grade (P = .005), DNA ploidy (P = .005), and lymph node involvement (P = .04). Stage, lymph node involvement, combined alterations of p27 and Ki-67, and combined alterations of all 5 ...

2011-06-01

433

NMR studies of Borrelia burgdorferi OspA, a 28 kDa protein containing a single-layer #beta#-sheet  

International Nuclear Information System (INIS)

The crystal structure of outer surface protein A (OspA) from Borrelia burgdorferi contains a single-layer #beta#-sheet connecting the N- and C-terminal globular domains. The central #beta#-sheet consists largely of polar amino acids and it is solvent-exposed on both faces, which so far appears to be unique among known protein structures. We have accomplished nearly complete backbone H, C and N and C";/H"#beta# assignments of OspA (28 kDa) using standard triple resonance techniques without perdeuteration. This was made possible by recording spectra at a high temperature (45 "oC ). The chemical shift index and "1"5N T_1/T_2 ratios show that both the secondary structure and the global conformation of OspA in solution are similar to the crystal structure, suggesting that the unique central #beta#-sheet is fairly rigid.

1998-05-01

434

Monovalent cation-induced structure of telomeric DNA: The G-quartet model  

Energy Technology Data Exchange (ETDEWEB)

We have investigated the structures formed by oligonucleotides composed of two or four repeats of the telomeric sequences from Oxytricha and Tetrahymena. The Oxytricha four-repeat molecule (d(T4G4)4 = Oxy-4) forms structures with increased electrophoretic mobility in nondenaturing gels containing Na+, K+, or Cs+, but not in gels containing Li+ or no added salt. Formation of the folded structure results in protection of a set of dG's from methylation by dimethyl sulfate. Efficient UV-induced cross-links are observed in Oxy-4 and the related sequence from Tetrahymena (d(T2G4)4 = Tet-4), and join thymidine residues in different repeats. Models proposed to account for these data involve G-quartets, hydrogen-bonded structures formed from four guanosine residues in a square-planar array. We propose that the G-quartet structure must be dealt with in vivo by the telomere replication machinery.

1989-12-01

435

Metallic and non-metallic properties of one-dimensional peanut-shaped fullerene polymers  

British Library Electronic Table of Contents (United Kingdom)

Some kind of one-dimensional (1D) peanut-shaped fullerene polymers (PSFPs) exhibit metallic properties, but their occurrence conditions are not yet clarified. By using the VASP (Vienna ab-initio simulation package) with density functional theory (DFT) and projector augmented wave (PAW) method, we have performed first-principles electronic structure calculations of four basic 1D PSFPs, T1, T2, T6, and T7 (the name of T1-T6 is the same as that of Wang et al. [9]) and two associated 1D PSFPs, T1SW1 and T6SW that are created by generalized Stone-Wales transformation (GSW) from T1 and T6. We found that almost regular six-membered rings connected throughout the tube are necessary to get metallic properties for the 1D PSFPs, although there may be several other conditions to expect metallic proper...

2011-01-01

436

Magnetic resonance imaging: early detection of central nervous system involvement in acquired immunodeficiency syndrome (AIDS)  

International Nuclear Information System (INIS)

Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2 weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature of these lesions is not lear. They ...

437

Magnetic properties of a SmNiSn single crystal  

Energy Technology Data Exchange (ETDEWEB)

The magnetic properties of a single crystal of SmNiSn with the orthorhombic {epsilon}-TiNiSi-type crystal structure have been investigated by magnetic susceptibility, magnetization and electrical resistivity measurements from 1.5 K to room temperature. Two anomalies have been found in the magnetic susceptibility, indicating an antiferromagnetic phase transition at T{sub N}=9.4 K and a second transition at 4.4 K. A large magnetic anisotropy has been found at low temperatures in the temperature and field dependencies of magnetic susceptibility and magnetization. Below 80 K, the easy axis of the magnetization is the c-axis. At T=2.0 K, the c-axis magnetization curve exhibits metamagnetic-like behavior at H{sub c}=42 kOe and reaches 0.54 emu/g at H=55 kOe, whereas for the a- and b-axis the magnetization is linear and smaller. The paramagnetic susceptibilities do not follow the Curie-Weiss law suggesting a large van Vleck contribution of the Sm ...

2003-04-01

438

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil  

International Nuclear Information System (INIS)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: ...

439

Kondo effect and impurity-impurity interaction in (La, Ce)B_6 alloys  

International Nuclear Information System (INIS)

Measurements of the magnetic susceptibility betweeen 0.03 and 300 K and of the magnetization between 0.05 and 10 K for magnetic fields up to 60kOe have been used to investigate effects from the interaction between the conduction electrons and local magnetic moments in (Lasub(1-x)Cesub(x))B_6 alloys (0.0007<=x<=0.10). For Ce concentrations x<0.006 the data show Kondo-type single impurity behaviour at low temperatures with a transition from a magnetic to a non-magnetic regime of the Ce ions. In the magnetic regime the impurity susceptibility follows a Curie-Weiss law, and in the non-magnetic regime it varies with T"2. An external magnetic field gradually restores the free-ion behaviour of the Ce impurities. For more concentrated alloys interactions between the impurities are observed. The RKKY interaction strength derived is more than two orders of magnitude smaller than in the Kondo system CuFe. Values of the s-f exchange integral, J, ...

1978-01-01

440

Intraoperative electron beam therapy and external photon beam therapy with lumpectomy as primary treatment for early breast cancer  

International Nuclear Information System (INIS)

Between 1984 and 1988, seven women with breast cancer were treated with intraoperative electron beam therapy (IOEBT). All patients were Caucasian. Patient age ranged from 37 to 62 (median 53) years. Histopathology was infiltrating duct carcinoma (6/7) or medullary carcinoma (1/7). Four tumors were staged T1 N0 MO, one T1 N1 MO, one T2 N1 MO, and one lesion was recurrent. At the time of primary lumpectomy or axillary node dissection, a dose of 10 or 15 Gy IOEBT was administered to the tumor bed with 6 or 9 MeV electrons through the lumpectomy wound. All patients received 45 or 50 Gy over five to six weeks with 6 MV photons to the breast and, in four patients, to the regional nodes. Three patients received adjuvant chemotherapy and tamoxifen. No post-operative complications were observed. All patients are alive as of August, 1989, with no evidence of recurrent disease. Excellent cosmesis is the rule. Clinical and technical aspects of treatment ...

441

High Magnetic Field NMR Studies of LiVGe$_2$O$_6$, a quasi 1-D Spin $S = 1$ System  

CERN Document Server

We report $^{7}$Li pulsed NMR measurements in polycrystalline and single crystal samples of the quasi one-dimensional S=1 antiferromagnet LiVGe$_2$O$_6$, whose AF transition temperature is $T_{\\text{N}}\\simeq 24.5$ K. The field ($B_0$) and temperature ($T$) ranges covered were 9-44.5 T and 1.7-300 K respectively. The measurements included NMR spectra, the spin-lattice relaxation rate ($T_1^{-1}$), and the spin-phase relaxation rate ($T_2^{-1}$), often as a function of the orientation of the field relative to the crystal axes. The spectra indicate an AF magnetic structure consistent with that obtained from neutron diffraction measurements, but with the moments aligned parallel to the c-axis. The spectra also provide the $T$-dependence of the AF order parameter and show that the transition is either second order or weakly first order. Both the spectra and the $T_1^{-1}$ data show that $B_0$ has at most a small effect on the alignment of the AF ...

2001-01-01

442

Gluon Plasma Frequency -- the Next-to-Leading Order Term  

CERN Document Server

The longitudinal-electric oscillations of the hot gluon system are studied beyond the well known leading order term at high temperature $T$ and small coupling $g$. The coefficient $\\eta$ in $\\omega^2 = m^2 \\, (1+ \\eta \\, g \\wu N \\, )$ is calculated, where \\hbox{$\\omega \\equiv \\omega (\\vc q =0)$} is the long-wavelength limit of the frequency spectrum, $N$ the number of colours and $m^2=g^2 N T^2/9$. In the course of this, for the real part of the gluon self-energy, the Braaten-Pisarski resummation programme is found to work well in all details. The coefficient $\\eta$ is explicitly seen to be gauge independent within the class of covariant gauges. Infrared singularities cancel as well as collinear singularities in the two-loop diagrams with both inner momenta hard. However, as it turns out, none of these two-loop contributions reaches the relative order $O(g)$ under study. The minus sign in our numerical result $\\; \\eta = -.18 \\; ...

1994-01-01

443

Evaluation of magnetization transfer ratios for breast tissues and breast diseases  

Energy Technology Data Exchange (ETDEWEB)

To determine MTRs for normal structures and benign diseases in the breast two-dimensional magnetization transfer imaging was performed in 62 patients and in 3 young female volunteers. With regard to the MTRs of measurements in the normal breast tissues, fat tissues which is close to simple cysts in MTRs show little transfer of longitudinal magnetization. MTRs of the muscles was 15.15{+-}6.22%, which exceeded those of breast parenchyma. The breast parenchyma didn`t show the change of MTR value due to the difference of patient age and due to variable amount of fat and fibrous tissues. Breast parenchyma in the two young volunteers clearly showed biphasic change of MTR values in accordance with the menstrual cycle; little transfer value was due to hydration in the postovulatory period and high transfer value was due to dehydration in the preovulatory period. In the remaining one volunteer during lactation period, mammary parenchyma shows sever decrease in MTR, because mammary gland is ...

1997-03-01

444

European facilities for accelerator neutrino physics: perspectives for the decade to come  

CERN Document Server

Very soon a new generation of reactor and accelerator neutrino oscillation experiments - Double Chooz, Daya Bay, Reno and T2K - will seek for oscillation signals generated by the mixing parameter theta_13. The knowledge of this angle is a fundamental milestone to optimize further experiments aimed at detecting CP violation in the neutrino sector. Leptonic CP violation is a key phenomenon that has profound implications in particle physics and cosmology but it is clearly out of reach for the aforementioned experiments. Since late 90's, a world-wide activity is in progress to design facilities that can access CP violation in neutrino oscillation and perform high precision measurements of the lepton counterpart of the Cabibbo-Kobayashi-Maskawa matrix. In this paper the status of these studies will be summarized, focusing on the options that are best suited to exploit existing European facilities (firstly CERN and the INFN Gran Sasso Laboratories) ...

2009-01-01

445

Direct observation of ordered orbital of YTiO_3 by the X-ray magnetic diffraction technique  

International Nuclear Information System (INIS)

X-ray magnetic diffraction (XMD) technique was applied to an orbital ordering compound of ferromagnetic YTiO_3 for the first time. The orbital-magnetic form factor #mu# _L(k) and the spin-magnetic form factor #mu# _S(k) were independently measured by utilizing the LS separation ability of the XMD. The #mu# _L(k) was measured for ten reciprocal-lattice points. No significant values of the #mu# _L(k) were observed for most of the reciprocal-lattice points within the estimated statistical errors, which suggested quenching of the orbital moment. The #mu# _S(k) was measured for 22 reciprocal-lattice points. Fourier synthesis of the #mu# _S(k) gave the spin density distribution m _S(r) in the real space. The obtained m _S(r) map shows the characteristic feature of the electron distribution of 3d electron in the t_2_g state of a Ti atom coordinated by O"2"- ions, in which the electrons are distributed away from the negative O"2"- ions. It is concluded ...

2005-08-01

446

Crystal-field excitations in uranium dioxide  

International Nuclear Information System (INIS)

The energy levels of the configuration f"2 in an eight-fold cubic crystal field (CF) have been calculated, and the results are used to explain the experimental spectrum of UO_2. The fourth-order CF potential turns out to be much smaller than usually assumed for this compound. This has an effect of reducing the J-mixing in the wavefunctions, particularly in the case of the ground state wavefunction. In spite of the strength of the CF, the ground state vertical stroke "3H_4T_2 right angle is found to be modified only slightly by the J-mixing effect; it consists of 89.4% "3He_4, and the remaining eleven components make up the rest. Very good correlation is obtained between the experimental and simulated energy-level schemes. The predominance of "3H_4 in the ground state consequently increases the value of the calculated effective magnetic moment. The results are compared with our previous predictions about the system, and relevant conclusions ...

1998-04-01

447

Cotton plants expressing CYP6AE14 double-stranded RNA show enhanced resistance to bollworms  

British Library Electronic Table of Contents (United Kingdom)

RNA interference (RNAi) plays an important role in regulating gene expression in eukaryotes. Previously, we generated Arabidopsis and tobacco plants expressing double-stranded RNA (dsRNA) targeting a cotton bollworm (Helicoverpa armigera) P450 gene, CYP6AE14. Bollworms fed on transgenic dsCYP6AE14 plants showed suppressed CYP6AE14 expression and reduced growth on gossypol-containing diet (Mao et?al., in Nat Biotechnol 25: 1307?1313, 2007). Here we report generation and analysis of dsRNA-expressing cotton (Gossypium hirsutum) plants. Bollworm larvae reared on T2 plants of the ds6-3 line exhibited drastically retarded growth, and the transgenic plants were less damaged by bollworms than the control. Quantitative reverse-transcription polymerase chain reaction (RT-PCR) showed that the CYP6AE1...

2011-01-01

448

A singlet - triplet T_+ based qubit  

International Nuclear Information System (INIS)

We theoretically model a nuclear-state preparation scheme that increases the coherence time of a two-spin qubit in a double quantum dot. The two-electron system is tuned repeatedly across a singlet-triplet level-anticrossing with alternating slow and rapid sweeps of an external bias voltage. Using a Landau-Zener-Stueckelberg model, we find that in addition to a small nuclear polarization that weakly affects the electron spin coherence, the slow sweeps are only partially adiabatic and lead to a weak nuclear spin measurement and a nuclear-state narrowing which prolongs the electron spin coherence. This resolves some open problems brought up by a recent experiment. We also show that the electronic two-spin states singlet and triplet T_+ are promising candidates for the implementation of a qubit in GaAs double quantum dots (DQD). A coherent superposition of the two-spin states is obtained by finite time Landau-Zener-Stueckelberg interferometry and the single qubit rotations are performed ...

2010-03-21

449

StoRHm: a protocol adapter for mapping SOAP based Web Services to RESTful HTTP format  

British Library Electronic Table of Contents (United Kingdom)

A protocol adapter ideally suited to enable enterprises to gradually transition from SOAP Web Services to RESTful HTTP Web Services without impacting existing clients is presented in this paper. The inherent advantage of such a transition is the visibility of RESTful HTTP messages to Web intermediaries such as caches. In contrast, SOAP messages are opaque, which disables Web intermediaries. While both approaches can use HyperText Transfer Protocol (HTTP) for message transfer, the paradigms contrast sharply. SOAP uses an interface specific approach whereas RESTful HTTP uses a Uniform Interface approach. SOAP marks up its payload with eXtensible Markup Language (XML) whereas in certain situations RESTful HTTP requires no XML. We present the disadvantages of the SOAP approach and outline how ...

2011-01-01

450

Response of ecosystem carbon exchange to warming and nitrogen addition during two hydrologically contrasting growing seasons in a temperate steppe  

British Library Electronic Table of Contents (United Kingdom)

Abstract A large remaining source of uncertainty in global model predictions of future climate is how ecosystem carbon (C) cycle feedbacks to climate change. We conducted a field manipulative experiment of warming and nitrogen (N) addition in a temperate steppe in northern China during two contrasting hydrological growing seasons in 2006 [wet with total precipitation 11.2% above the long-term mean (348 mm)] and 2007 (dry with total precipitation 46.7% below the long-term mean). Irrespective of strong intra- and interannual variations in ecosystem C fluxes, responses of ecosystem C fluxes to warming and N addition did not change between the two growing seasons, suggesting independence of warming and N responses of net ecosystem C exchange (NEE) upon hydrological variations in the temperate ...

2009-01-01

451

Raney-platinum film electrodes for potentially implantable glucose fuel cells. Part 1: Nickel-free glucose oxidation anodes  

British Library Electronic Table of Contents (United Kingdom)

We present a novel fabrication route yielding Raney-platinum film electrodes intended as glucose oxidation anodes for potentially implantable fuel cells. Fabrication roots on thermal alloying of an extractable metal with bulk platinum at 200^oC for 48h. In contrast to earlier works using carcinogenic nickel, we employ zinc as potentially biocompatible alloying partner. Microstructure analysis indicates that after removal of extractable zinc the porous Raney-platinum film (roughness factor ~2700) consists predominantly of the Pt3Zn phase. Release of zinc during electrode operation can be expected to have no significant effect on physiological normal levels in blood and serum, which promises good biocompatibility. In contrast to previous anodes based on hydrogel-bound catalyst particles the ...

2010-01-01

452

Opportunistic esophagitis in AIDS: Radiographic diagnosis  

International Nuclear Information System (INIS)

Between 1983 and 1986, 35 of 90 patients with acquired immunodeficiency syndrome (AIDS) had double-contrast esophagograms to rule out opportunistic esophagitis. The radiographs were reviewed without knowledge of the clinical or endoscopic findings. Candida esophagitis was diagnosed radiographically in 17 patients who had varying degrees of plaque formation and viral esophagitis in three who had discrete ulcers without plaques. All three patients with viral esophagitis (herpes in 2 and cytomegalo virus in one) and 15 of 17 with Candida esophagitis had endoscopic and/or clinical corroboration of the radiographic diagnosis. Thus, the authors' experience suggests that fungal and viral esophagitis can often be differentiated on double-contrast esophagography, so that appropriate antifungal or antiviral therapy can be instituted without need for endoscopic intervention.

453

Feasibility study of the iterative x-ray phase retrieval algorithm  

International Nuclear Information System (INIS)

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

2009-01-01

454

Ewing's sarcoma recurrence vs radiation necrosis in dynamic contrast-enhanced MR imaging: a case report  

International Nuclear Information System (INIS)

Purpose. We report a case of Ewing's sarcoma in the right distal femur in a 6-year-old male to demonstrate how dynamic contrast-enhanced magnetic resonance imaging (DEMRI) findings predicted histopathology. Materials and methods. DEMRI was performed at presentation and during and after completion of chemotherapy and radiation therapy. Histopathologic studies were done at presentation, at 77 weeks (20 weeks after a pathological fracture), and from the en bloc resection at 104 weeks. Results. DEMRI predicted the early tumor response, absence of tumor recurrence, presence of necrosis and lack of fracture healing, confirmed by histopathology. Conclusion. DEMRI is a clinically useful tool in managing Ewing's sarcoma. (orig.)

1999-04-01

455

Digital processing to improve image quality in real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively.

1985-01-01

456

Digital processing to improve image quality in real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively. (orig.).

1985-01-01

457

Characteristic features of intracranial meningiomas on magnetic resonance tomography  

International Nuclear Information System (INIS)

Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).

458

Angiography of the head using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Forty-seven subtraction images of FCR were compared with subtraction images of conventional angiography of the head. Quality of the FCR images were equal or superior to that of conventional angiography. Antero-posterior projection of external carotid arteriography by FCR was most useful because of its wide dynamic range. As contrast resolution of FCR is superior to that of conventional angiography, only half diluted contrast media was needed. As for spacial resolution, FCR is slightly inferior to conventional angiography. However, most vessels which are clinically important were adequately demonstrated. A weak point of FCR which should be improved is relatively long time to process the images after radiation exposure. (author).

1985-01-01

459

Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from transmission images. We ...

2009-03-01

460

Stereotactic iridium-192 interstitial brachytherapy for intracranial malignant tumors; Combined with hyperthermia  

Energy Technology Data Exchange (ETDEWEB)

The results of interstitial brachytherapy in 13 patients with malignant brain tumors (malignant glioma 9 cases, metastatic brain tumor 4 cases) were reported. In all patients, Ir-192 thin wires were implanted temporarily in afterloading catheters, which were implanted appropriately by means of MRI or CT guided stereotactic technique. Clinical results on CT scan were as follows: CR (complete response) 1 case, PR (partial response) 6 cases and NC (no change) 6 cases. Even in the NC group, tumor growth was inhibited temporarily. Tumor free intervals were ranged 2-17 months. In early series, the intervals were about 2 months due to incomplete arrangement of radioactive implants. In recent series, prolongation of tumor free interval more than 12 months was achieved due to precise arrangements of implants. MRI guided stereotactic interstitial brachytherapy may provide safe and precise intracranial arrangements of implants, which yield high radiation ...

1990-05-01

461

Stereotactic iridium-192 interstitial brachytherapy for intracranial malignant tumors  

International Nuclear Information System (INIS)

The results of interstitial brachytherapy in 13 patients with malignant brain tumors (malignant glioma 9 cases, metastatic brain tumor 4 cases) were reported. In all patients, Ir-192 thin wires were implanted temporarily in afterloading catheters, which were implanted appropriately by means of MRI or CT guided stereotactic technique. Clinical results on CT scan were as follows: CR (complete response) 1 case, PR (partial response) 6 cases and NC (no change) 6 cases. Even in the NC group, tumor growth was inhibited temporarily. Tumor free intervals were ranged 2-17 months. In early series, the intervals were about 2 months due to incomplete arrangement of radioactive implants. In recent series, prolongation of tumor free interval more than 12 months was achieved due to precise arrangements of implants. MRI guided stereotactic interstitial brachytherapy may provide safe and precise intracranial arrangements of implants, which yield high radiation ...

1990-01-01

462

Radiation therapy for Ewing's sarcoma: Results from Memorial Sloan-Kettering in the modern era  

International Nuclear Information System (INIS)

Purpose: To evaluate the outcomes of patients with Ewing's sarcoma family of tumors (ESFT) treated with modern radiotherapy techniques with MRI along with optimal chemotherapy. Methods and Materials: The records of all 60 patients with ESFT who received radiation to the primary site between 1990 and 2004 were reviewed. All patients received chemotherapy, including vincristine, doxorubicin, cyclophosphamide, ifosfamide, and etoposide. Radiation was used as the sole modality for local control in 31 patients and was given either before (n = 3) or after surgical resection (n = 26) in the remainder. All patients had MRI and CT scan-based treatment planning, and 43% received intensity-modulated radiation therapy. Radiation doses ranged from 30 Gy to 60 Gy (median, 51 Gy), and 35% received hyperfractionated radiotherapy. Results: Median age was 16 years (range, 2-40 years). Because of selection bias for radiotherapy, the majority of primary tumors ...

2006-02-01

463

Outcome of moderately dosed radiosurgery for limited brain metastases. Report of a single-center experience  

International Nuclear Information System (INIS)

Purpose: Efficacy and safety of the own single-center experience with moderately dosed radiosurgery (SRS) for limited (one to four) brain metastases were analyzed and correlated with patient- and treatment-related variables. Patients and Methods: Between 05/1998 and 10/2006, 93 patients received SRS for a total of 142 brain metastases. The median number of brain metastases treated per patient was one (range, one to four). 46 patients (49%) received initial SRS alone, 13 patients (14%) SRS with up-front whole-brain radiotherapy (WBRT), and 34 patients (37%) SRS for recurrent metastases after WBRT. Median dose was 16 Gy (range, 10-20 Gy). Results: Median overall survival (OS) was 7.5 months. The actuarial 6- and 12-month data for OS were 60% and 35%, for local brain control (LBC) 87% and 79%, and for distant brain control (DBC) 48% and 37%, respectively. Only ten of 46 patients (22%) with initial SRS alone ultimately received WBRT. Ten patients suffered from seizures within 3 months ...

2010-02-01

464

Optimizing the fMRI data-processing pipeline using prediction and reproducibility performance metrics: I. A preliminary group analysis.  

Science.gov (United States)

We argue that published results demonstrate that new insights into human brain function may be obscured by poor and/or limited choices in the data-processing pipeline, and review the work on performance metrics for optimizing pipelines: prediction, reproducibility, and related empirical Receiver Operating Characteristic (ROC) curve metrics. Using the NPAIRS split-half resampling framework for estimating prediction/reproducibility metrics (Strother et al., 2002), we illustrate its use by testing the relative importance of selected pipeline components (interpolation, in-plane spatial smoothing, temporal detrending, and between-subject alignment) in a group analysis of BOLD-fMRI scans from 16 subjects performing a block-design, parametric-static-force task. Large-scale brain networks were detected using a multivariate linear discriminant analysis (canonical variates analysis, CVA) that was tuned to fit the data. We found that tuning the CVA model and spatial smoothing ...

2004-01-01

465

Long-Term Follow-Up of Percutaneous Balloon Angioplasty in Adult Aortic Coarctation  

International Nuclear Information System (INIS)

Purpose: To assess long-term outcomes following percutaneous transluminal angioplasty (PTA) of congenital aortic coarctation in adults.Methods: Seventeen patients underwent PTA for symptomatic adult coarctation of the aorta. Sixteen patients, with a mean age of 28 years (range 15-60 years), were reviewed at a mean interval after angioplasty of 7.3 years (range 1.5-11 years). Assessment included magnetic resonance imaging (MRI), Doppler echocardiography, and clinical examination. Current clinical measurements were compared with pre- and immediate post-angioplasty measurements.Results: At follow-up 16 patients were alive and well. The patient not included in follow-up had undergone surgical repair and excision of the coarctation segment following PTA. Mean brachial systolic blood pressure for the group decreased from 174 mmHg before angioplasty to 130 mmHg at follow-up (p 0.0001). The mean gradient had fallen significantly from 50.9 to 17.8 at follow-up (p = 0.001). ...

2000-09-01

466

Functional magnetic resonance imaging of the normal and abnormal visual system in early life.  

DEFF Research Database (Denmark)

Functional magnetic resonance imaging (fMRI) in young children may provide information about the development of the visual cortex, and may have predictive value for later visual performance. The purpose of this study was to evaluate the usefulness of fMRI for examining cerebral processing of vision in very young infants and in infants with brain damage. We examined 15 preterm infants, 12 children suspected of having a cerebral visual impairment and 10 children with a normal visual system, all of whom were either spontaneously asleep or sedated with chloral hydrate. Cortical response to stroboscopic light stimulation could be demonstrated in all technically acceptable data sets from children with a post-menstrual age (PMA) of > 41 weeks, but not in younger infants. Children < 60 weeks PMA showed either a blood oxygenation level-dependent (BOLD) signal increase or decrease, while all older children showed a signal decrease. The activated ...

2000-01-01

467

Facet joint injuries in acute cervical spine trauma : evaluation with CT and MRI  

Energy Technology Data Exchange (ETDEWEB)

To evaluate injury patterns of facet joints and associated soft tissue injuries in patients with acute traumatic cervical facet joint injuries. From among patients with cervical spine trauma, 27 with facet joint injuries, as seen on CT and MRI, were chosen for this study. CT scans were analyzed with regard to the location of facet joint injury, the presence or absence of facet dislocation or fracture, and other associated fractures. MR images were analyzed with regard to ligament injury, intervertebral disc injury, intervertebral disc herniation, and spinal cord injury. The most common location of facet joint injury was C6-7 level(n=10), followed by C5-6(n=8). Among these 27 patients with facet joint injuries, 12(44%) had bilateral injuries and 15(56%) unilateral injuries. Facet fractures were present in 17 cases(63%) and the fracture of inferior facet was more frequent than superior. Patterns of fracture were vertical, transverse, or comminuted, but vertical ...

1999-05-01

468

Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy  

International Nuclear Information System (INIS)

High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 mm3, 2.2 s/image, 0.3 ...

2008-11-21

469

Variosorb - advanced gas sorption with powder sorbent technology  

Energy Technology Data Exchange (ETDEWEB)

In contrast to plants based on formed coal where, for the purposes of calculating sorbent volume, only one activated charcoal design can be used in a filter layer, powder sorbent technology enables two variations to be used. This can be either a mixture of a number of different activated charcoal forms in one and the same filter layer, or the combination of a number of filter layers on top of each other, each containing a different activated charcoal form, in one and the same construction unit.

1983-01-01

470

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

471

The Percus-Yevick theory is alive and well  

Science.gov (United States)

The pressure of a 6:12 fluid is obtained from the Percus-Yevick theory at the temperature kT/? = 1.35. The energy equation results are in excellent agreement with machine calculation results in contrast to the pressure and compressibility equation results. Present address: Diffusion Research Unit, The Australian National University, Canberra, ACT, Australia.

1970-01-01

472

Quantum tachyons in Schwarzschild space-time  

Energy Technology Data Exchange (ETDEWEB)

The wave equation of a spinless tachyon is studied in Schwarzschild space-time. In contrast to earlier approaches to the problem, it is shown that tachyonic static solutions satisfy a simple second-order linear differential equation regardless of the mass of the black hole and the mass parameter of the tachyon. Physical implication of the present approach is discussed. Using Langer modification of the WKB (Wentzel-Kramers-Brillouin) boundary condition an expression similar to the Bohr-Sommerfeld quantization condition is derived.

1981-02-01

473

Phase-plate electron microscopy: a novel imaging tool to reveal close-to-life nano-structures  

UK PubMed Central (United Kingdom)

After slow progress in the efforts to develop phase plates for electron microscopes, functional phase plate using thin carbon film has been reported recently. It permits collecting high-contrast images...Full Text Available

2009-03-01

474

Non-selective cervical and cerebral three-dimensional rotational angiography  

International Nuclear Information System (INIS)

To evaluate the usefulness of three-dimensional (3D) rotational angiography, cervical carotid or cerebral angiography was done without catheterizing the branches of the thoracic aorta. A 5-Fr pig-tail type catheter was passed into the ascending aorta via the radial artery or the femoral artery. Optimal carotid angiogram views were obtained using approximately 45 ml of contrast medium at a flow rate of 15 ml/sec. Optimal cerebral angiogram views were obtained using approximately 70 ml of contrast medium at a flow rate of 20 ml/sec. The contrast medium concentration was 300 to 350 mgI/ml. A satisfactory view could be obtained in 5 of 8 (63%) cases on cervical carotid 3D angiography and in 8 of 14 (57%) cases on cerebral 3D angiography. In all cases, no complications were noted. This method offers the advantages of requiring a relatively short procedure time and a decrease in radiation exposure. Further studies are needed to ...

2007-09-01

475

Measurement of the Self-Diffusion Coefficient of Water as a Function of Position in Wheat Grain Using Nuclear Magnetic Resonance Imaging  

UK PubMed Central (United Kingdom)

A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available

1988-01-01

476

Maximum imaging depth of two-photon autofluorescence microscopy in epithelial tissues  

Science.gov (United States)

Endogenous fluorescence provides morphological, spectral, and lifetime contrast that can indicate disease states in tissues. Previous studies have demonstrated that two-photon autofluorescence microscopy (2PAM) can be used for noninvasive, three-dimensional imaging of epithelial tissues down to approximately 150 ?m beneath the skin surface. We report ex-vivo 2PAM images of epithelial tissue from a human tongue biopsy down to 370 ?m below the surface. At greater than 320 ?m deep, the fluorescence generated outside the focal volume degrades the image contrast to below one. We demonstrate that these imaging depths can be reached with 160 mW of laser power (2-nJ per pulse) from a conventional 80-MHz repetition rate ultrafast laser oscillator. To better understand the maximum imaging depths that we can achieve in epithelial tissues, we studied image contrast as a function of depth in tissue phantoms with a range of relevant ...

2011-02-01

477

MAGNETIC ELECTRON MICROSCOPE UEMB-100  

Science.gov (United States)

A new magnetic electron microscope, UEMB-100, was designed with an increased electron-optical parameter. The electron-optical system consists of an electron canon (the high voltage is supplied by armored lead) and condensed, objective, intermediate, and projection lenses. In contrast to other native apparatuses, the microscope has a high resolving property (up to 20A) snnd great universality. (tr-auth)

1958-07-01

478

Lung studies with spiral CT. pitch 1 versus pitch 2  

International Nuclear Information System (INIS)

In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality.

1999-03-01

479

Laser weapons. II - Strategic laser weapons  

Science.gov (United States)

Potential strategic missions for laser weapons, particularly those involving space-based lasers, are discussed. The functions of space-based lasers and the history of their conceptual development are summarized, and the problems of implementing such systems, including the building of a suitable laser and power source, and resolving the problem of optics, are discussed. Ongoing development programs are described, and the contrasting views of the necessity and usefulness of strategic laser systems are set forth.

1982-07-01

480

Kinetic estimation of infused Lipiodol within hepatoma using CT dynamic study  

Energy Technology Data Exchange (ETDEWEB)

Distribution of Lipiodol within hepatic tumor was evaluated using serial computed tomography. Imagistic Lipiodol transition into the tumor via hepatic artery was slower than that of water soluble contrast medium, spreading to central part first and turn to peripheral part of the tumor. This method was thought to be useful to clarify Lipiodol distribution in hepatic tumor and to decide the method or necessity of additional trans-arterial therapy. (author).

1991-02-01

481

Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol  

Energy Technology Data Exchange (ETDEWEB)

Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both contrast agents were ...

1999-09-01

482

Instantaneous energy density as a feature for gear fault detection  

Science.gov (United States)

In this work, energy-based features for gear fault diagnosis and prediction are proposed. The instantaneous energy density is shown to obtain high values when defected teeth are engaged. Three methods are compared in terms of sensitivity, reliability and computation effectiveness. The Wigner Ville distribution is contrasted to the wavelet transform and the newly proposed empirical mode decomposition scheme. It is shown that all three methods are capable of a reliable prediction. An empirical law, which relates the energy content to the crack magnitude is established.

2006-07-01

483

Implications of biodiversity of short rotation coppice  

Environmental Research Database

DescriptionFossil fuels have a detrimental effect on the environment. They lead to the increase in atmospheric carbon dioxide which has been documented over the last 150 years. In contrast, some sources of renewable energy are near carbon neutral. Renewable energy produced from biomass constitutes such a type of energy and so has many potential advantages. The Energy White Paper (DTI et al., 2003) identifies bioenergy as an important means of meeting the Government's energy and environment objectives, in [continued...

2009-01-31

484

IDEAS: Journal of International Trade & Economic Development, Taylor and Francis Journals  

Wastenet

... (restricted)] 101-127 On the transmission of exchange rate fluctuations to the macroeconomy: Contrasting evidence for developing and developed countries by Magda Kandil [Downloadable! (restricted)] 2005, Volume 14, Issue 4 377-405 Predicting the poverty impacts of trade reform by Thomas Hertel & Jeffrey Reimer [Downloadable! (restricted)] 407-435 Sustaining imperfectly credible trade liberalization: Do the rate of tariff reduction ...

485

How to decorate FIB cross sections using plasma etch for SEM observation  

Energy Technology Data Exchange (ETDEWEB)

The Focused-Ion-Beam (FIB) is a powerful tool for fast, precision cross-sectioning and inspection of submicron defects in multilayered integrated circuit devices. However, the low contrast between the layers in FIB cross-sections can make the feature of interest difficult to observe, which has become a limitation for FIB cross-sectioning. A technique using plasma etch to decorate the FIB cross-sections has proven to be a simple solution to overcome this limitation.

1995-12-31

486

Geosynchronous orbit magnetopause crossings  

Energy Technology Data Exchange (ETDEWEB)

In this study we extend the analysis of magnetopause crossings observed with Magnetospheric Plasma Analyzer measurements to examine a much larger statistical data set. This study examines 39 maiznetosheath/LLBL intervals from 79 spacecraft-months of observations: these observations were taken from a survey of data from the start of each spacecraft mission and extending through March 1993. In contrast to the previous findings, we find no evidence for a significant dawn/dusk asymmetry in geosynchronous magnetopause crossings.

1994-07-01

487

Features of laser damage to elastic polymers  

Energy Technology Data Exchange (ETDEWEB)

Threshold pump intensity values leading to irreversible damage to colored laser elements based on elastic polymers were measured. The damage to colored elastomers is connected with absorbing microinclusions but is independent of molecular absorption. It is shown that damage to the elastomers has a pronounced threshold character in contrast to the microdamage accumulation effect in glassy polymers. The damage threshold for elastomers is 1.5 times higher, which is connected with the absence of microstresses (characteristics for organic glasses) in the specimens. 13 references.

1988-03-01

488

Extended superconformal algebra from super Toda field theory  

International Nuclear Information System (INIS)

We propose and construct a new type of extended superconformal algebra (ESA) based on the super Toda field theory. Both in the N = 1 ESA and in the N = 2 ESA, an arbitrary value of the central charge is allowed in contrast with the previously known super W-algebra. The generators of ESA are interpreted as the constants of motion in the super Toda field theory. (orig.).

1991-01-01

489

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

Energy Technology Data Exchange (ETDEWEB)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.

1987-03-01

490

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).

1987-01-01

491

Equine infectious anemia virus and human immunodeficiency virus DNA synthesis in vitro: characterization of the endogenous reverse transcriptase reaction.  

UK PubMed Central (United Kingdom)

The endogenous reverse transcriptase reaction of equine infectious anemia virus (EIAV) has been studied, and conditions allowing synthesis of full-length minus-strand DNA have been determined. In contrast...Full Text Available

1991-04-01

492

Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography  

International Nuclear Information System (INIS)

Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% ...

2010-08-01

493

Elucidating novel pathways and regulation of nitrogen assimilation in alpha proteobacteria exemplified by the soil organism Paracoccus denitrificans  

Environmental Research Database

DescriptionThe importance of inorganic nitrate for the nutrition and growth of marine and freshwater autotrophic phytoplankton has long been recognised, in particularly because of the 'blooms' formed in nitrate and phosphate polluted water and their possible roles as carbon dioxide sinks. By contrast, the utilisation of nitrate by heterotrophic bacteria has historically received less attention. Up until now, the primary role of heterotrophic bacteria has classically been considered to be the decomposition [continued...

2010-01-31

494

Controllable Subspaces of Open Quantum Dynamical Systems  

International Nuclear Information System (INIS)

This paper discusses the concept of controllable subspace for open quantum dynamical systems. It is constructively demonstrated that combining structural features of decoherence-free subspaces with the ability to perform open-loop coherent control on open quantum systems will allow decoherence-free subspaces to be controllable. This is in contrast to the observation that open quantum dynamical systems are not open-loop controllable. To a certain extent, this paper gives an alternative control theoretical interpretation on why decoherence-free subspaces can be useful for quantum computation.

2008-01-15

495

Collaborations in Mind, Brain, and Education: An Analysis of Researcher-Practitioner Partnerships in Three Elementary School Intervention Studies  

British Library Electronic Table of Contents (United Kingdom)

A reciprocal relationship informing both research and practice is one of the primary goals in the emerging field of Mind, Brain, and Education (MBE), yet the field has little documentation and analysis of such collaborations. In this article, we present case studies of three research-practice partnerships taking place between scientists and educators. By comparing and contrasting these three partnerships we expect to illuminate common characteristics, challenges, and benefits that come with doing MBE work.

2011-01-01

496

Campylobacter jejuni Fatty Acid Synthase II: Structural and functional analysis of ?-hydroxyacyl-ACP dehydratase (FabZ)  

UK PubMed Central (United Kingdom)

Fatty acid biosynthesis is crucial for all living cells. In contrast to higher organisms, bacteria use a type II fatty acid synthase (FAS II) composed of a series of individual proteins, making...Full Text Available

2009-03-06

497

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

498

Adiabatic theory of Wannier threshold laws and ionization cross sections  

Energy Technology Data Exchange (ETDEWEB)

The Wannier threshold law for three-particle fragmentation is reviewed. By integrating the Schroedinger equation along a path where the reaction coordinate R is complex, anharmonic corrections to the simple power law are obtained. These corrections are found to be non-analytic in the energy E, in contrast to the expected analytic dependence upon E.

1994-12-31

499

A predictive integrated voltage regulator and power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

An integrated voltage regulator and power system stabilizer based on one step ahead prediction is presented. The fixed parameter predictive control scheme is shown capable of providing consistently good voltage response and contribution to system damping over a wide range of operating conditions and system configuration. This is in contrast to the case with conventional automatic voltage regulator and power system stabilizer where performance varies widely with the operating situation and can even cause system instability. (author)

1995-04-01

500

#sigma#_e_e_#gamma#_#gamma#"t"o"t at e"+e"- colliders  

International Nuclear Information System (INIS)

In this talk I briefly summarize different models for #sigma#_2_#gamma#"t"o"t (e"+e"-#->##gamma##gamma##->#hadrons) and contrast model predictions with the data. I will then discuss the capability of the future e"+e"- and #gamma##gamma# colliders to distinguish between various models and end with an outlook for future work.

2001-07-09