WorldWideScience
 
 
1

Patient-reported-outcomes in subjects with painful lumbar or cervical radiculopathy treated with pregabalin: evidence from medical practice in primary care settings  

UK PubMed Central (United Kingdom)

The objective of this study was to evaluate the effect of pregabalin in painful cervical or lumbosacral radiculopathy treated in Primary Care settings under routine clinical practice. An observational,...Full Text Available

2010-06-01

2

Photocoagulation of the fovea.  

UK PubMed Central (United Kingdom)

The visual outcome, histopathology, and electrodiagnostic tests of a man with a malignant melanoma of the choroid who received foveal argon laser photocoagulation prior to enucleatiion are described....Full Text Available

1978-01-01

3

Osteoid osteoma near the intervertebral foramen may induce radiculopathy through tumorous inflammation  

UK PubMed Central (United Kingdom)

Osteoid osteoma of the spine is a relatively rare bone-forming tumor. Pain that is worse at night and relieved by aspirin and muscle contracture are the most characteristic symptoms of spinal osteoid...Full Text Available

4

Foraminal stenosis complicating retained broken epidural needle tip -A case report-  

UK PubMed Central (United Kingdom)

Lumbar epidural anesthesia is useful in a variety of chronic benign pain syndromes, including lumbar radiculopathy, low back pain syndrome, spinal stenosis, and vertebral compression fractures. Given...Full Text Available

2010-12-01

5

Foraminal stenosis complicating retained broken epidural needle tip -A case report-.  

Science.gov (United States)

Lumbar epidural anesthesia is useful in a variety of chronic benign pain syndromes, including lumbar radiculopathy, low back pain syndrome, spinal stenosis, and vertebral compression fractures. Given the increased number of epidural nerve blocks being performed, some have reported unexplained complications of a transient or permanent nature and with varying degrees of severity. However, no case has been reported of a broken epidural needle tip retained in the lumbar facet joint area. This represents the first reported case presentation of foraminal stenosis developing in a patient after a retained epidural needle tip. PMID:21286465

2010-12-31

6

Spin-lattice relaxation in A-15 type intermetallic compounds  

International Nuclear Information System (INIS)

The temperature dependence of T_1 spin-lattice relaxation time on "5"1V, "6"9Ga, "7"1Ga and Knight shift on "5"1V and "2"9Si nuclei in polycrystalline V_3Si, V_3Ga, V_3Ge and in the monocrystal V_3Si in normal state is investigated. For V_3Si and V_3Ga a rapid growth (T_1T)"-"1 is observed with temperature decrease while for V_3Ge the maximum (T_1T)"-"1 at T approximately equal to 60 K has been found. The temperature dependence peculiarities have been discussed on the basis of theoretical models available and zone structure calculations for A-15 compounds. The T_1 anisotropy and possibility of its experimental discovery are considered. Anisotropic contribution in ...

7

Growth-Phase-Dependent Expression of Virulence Factors in an M1T1 Clinical Isolate of Streptococcus pyogenes  

UK PubMed Central (United Kingdom)

The effect of growth phase on expression of virulence-associated factors was studied by Northern hybridization in an M1T1 clinical isolate of Streptococcus pyogenes. Expression of M...Full Text Available

1999-10-01

8

Obtaining a contact lens acquired electroretinogram in the presence of topical anesthetic hypersensitivity.  

Science.gov (United States)

Clinical circumstances often demand flexibility in electrodiagnostic procedures. We present a clinical case that required alteration of our routine full-field electroretinography technique. The patient presented with reports of allergy to Xylocaine (lidocaine) and refused the use of any type of topical anesthetic drops. This conflicted with our routine ERG method that combines the use of the Henkes Lovac hard contact lens and the topical anesthetic Alcaine (proparacaine hydrochloride). We acquired a successful electroretinogram without topical anesthesia by using a "piggy-back" system involving the interposition of a soft hydrophilic contact lens between the cornea and the recording hard lens. The procedure yielded excellent ERG recordings and was well tolerated. This non-routine technique was also compared to our standard ERG technique using a normal volunteer. It appears that this proposed "piggy-back" technique is a useful alternative to routine ERG procedure in ...

2007-11-06

9

Production and decay of scalar top squarkonium bound states  

International Nuclear Information System (INIS)

In this paper we discuss possible signatures for the production of scalar t_1t_1"* (top squarkonium) bound states #sigma#_t_1 at hadron colliders, where t_1 is the lighter scalar top eigenstate. We first study the decay of #sigma#_t_1; explicit expressions are given for all potentially important decay modes. If t_1 has unsuppressed two-body decays, they will always overwhelm the annihilation decays of #sigma#_t_1. Among the latter, we find that usually either the gg or hh final state dominates, depending on the size of the off-diagonal entry of the top squark mass matrix; h is the lighter neutral scalar Higgs boson of the minimal supersymmetric model. If m_#sigma#_t happens to be close to the mass ...

12

Higgs boson production in association with squark pairs in the MSSM at the LHC  

CERN Document Server

We study neutral and charged Higgs boson production in association with stop and sbottom squarks at the Large Hadron Collider (LHC), within the so-called M-SUGRA scenario, i.e., the Supergravity (SUGRA) inspired Minimal Supersymmetric Standard Model (MSSM). For low values of \\tan\\beta only the cases \\tilde{t}_1\\tilde{t}_1^* H, \\tilde{t}_1\\tilde{t}_1^* h and than 30 a variety of signals involving all Higgs bosons can be accessed, at high collider luminosity. The dependence of these reactions on the M-SUGRA parameters might further allow one to pin down the actual structure of the underlying Supersymmetric (SUSY) model.

1999-01-01

14

Approximate Analysis of an Unreliable M/M/2 Retrial Queue  

Science.gov (United States)

... by r repair crews, thus creating a second queue, that of failed terminals. The authors defined a trivariate stochastic process as follows: X(t) = 1 if ...

2007-03-01

15

Large T1 oligonucleotides of Moloney leukemia virus missing in an env gene recombinant, HIX, are present on an intracellular 21S Moloney viral RNA species.  

UK PubMed Central (United Kingdom)

HIX, a recombinant derived from Moloney leukemia virus, has an envelope glycoprotein different from that of the Moloney virus. HIX and Moloney viruses share the majority of the large T1 oligonucleotides...Full Text Available

1978-06-01

16

Comparative evaluation of Computed Tomography and Magnetic Resonance Imaging (1.5 T) in the detection of brain metastases  

International Nuclear Information System (INIS)

Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of ...

1991-01-01

17

Severity of iron deficiency anemia and its relationship to growth and morbidity  

Energy Technology Data Exchange (ETDEWEB)

The relationships between severity of iron deficiency anemia, response to iron treatment, respiratory and gastrointestinal illness and weight changes were assessed before (T1) and after (T2) iron therapy. Seventy-five pre-school children from rural Guatemala received daily oral iron (ferrous sulfate 5 mg/kg/day) for eleven weeks, and were classified into one of three groups: (1) severe iron deficient (Hgb < 9.25 g/dl at T1 and > 1g/dl Hgb response (T2-T1) to Fe Rx; (2) moderately iron deficient (Hgb 9.25 g/dl to 11.5 g/dl and T2-T1 > 1g/dl); (3) normal controls (Hgb > 11.5 g/dl and T2-T1 < 1g/dl). When both severely and moderately anemic children were pooled together, there was a statistical significant difference between the number of days ill with ...

1986-03-01

18

Comparison of turbo inversion recovery magnitude (TIRM) with T2-weighted turbo spin-echo and T1-weighted spin-echo MR imaging in the early diagnosis of acute osteomyelitis in children  

Energy Technology Data Exchange (ETDEWEB)

Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better ...

1998-11-01

19

Nuclear magnetic resonance imaging of the abnormal live rat and correlations with tissue characteristics  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance (NMR) images of live rats with sterile and pyogenic abscesses, hematomas, and various implanted and spontaneous neoplasms demonstrated good contrast differentiation between pathologic and surrounding normal tissues. This differentiation was maximal when both the T1 and T2 tissue relaxation times were used as criteria. Neoplasms have a broad range of T1 and T2 values and may be confused with abscesses or hematomas. Tissue rate constants (1/T1 and 1/T2) are mainly dependent on total water content, the exception being fat, which has a 1/T2 value much shorter than that expected on the basis of water content alone.

1981-10-01

20

New pulse sequence for simultaneous T1, T2, and RHO determination in whole-body proton MR imaging  

International Nuclear Information System (INIS)

A newly developed method to support tissue characterization in routine MR imaging is presented. It represents a compromise between the practical requirements of clinical routine (short measurement time, multisection imaging) and the necessary accuracy of the relaxation parameter evaluation. The sequence employed is a modification of the PHAPS technique and works with two excitation pulses. It allows the simultaneous acquisition of all measurement data for the subsequent T1, T2, and rho evaluations. T1 is determined with a specially designed computation formula based on four signal ratios. A multiexponential T2 analysis is performed with use of 28 echoes. From these parameters, relative proton density can be computed.

 
 
 
 
21

The RpoT Regulon of Pseudomonas putida DOT-T1E and Its Role in Stress Endurance against Solvents?  

UK PubMed Central (United Kingdom)

Pseudomonas putida encodes 20 extracytoplasmic sigma factors (ECFs). In this study, we show that one of these ECFs, known as ECF-Pp12...Full Text Available

2007-01-01

22

SirT1 brings stemness closer to cancer and aging  

UK PubMed Central (United Kingdom)

Sirtuin 1 acts in various cell processes, deacetylating both chromatin and non-histone proteins, and its role in cancer and aging has long been studied and debated. Here we discuss another aspect of...Full Text Available

23

Original Research Article: Longitudinal Relationships of Depressive Symptoms to Pain Intensity and Functional Disability Among Children with Disease-Related Pain  

UK PubMed Central (United Kingdom)

ObjectiveTo examine the longitudinal relationship between depressive symptoms at study entry (T1) on pain intensity (PI) and functional disability over a 1-year period...Full Text Available

2006-01-01

24

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

25

Molecular dynamic study of different regions of Angelin Pedra (Himenolobium paetrum) wood by low field NMR  

International Nuclear Information System (INIS)

Angelin Pedra is a specie found in the north of Mato Grosso State in Brazil, where an expressive volume of waste of this wood is produced. An alternative to recycle this waste is to produce wood plastic composites. However, structural and chemical investigations are fundamental to generate information for this use. In the present work, low field NMR was used to determine the spin-lattice and spin-spin relaxation times with objective to investigate the molecular dynamic behavior of the alburnu and cerne regions of Angelin Pedra aiming at a potential use of this waste wood in polymeric composites. The results of the proton spin-lattice relaxation time (T1H) and the proton spin-spin relaxation time (T2H) showed at least three different mobility domains for both regions. Among the values, one was very flexible and other was rigid. Knowing that wood is a polymer composite basically constituted by cellulose, hemicellulose and lignin can attribute the ...

2005-11-06

26

Metallic and non-metallic properties of one-dimensional peanut-shaped fullerene polymers  

British Library Electronic Table of Contents (United Kingdom)

Some kind of one-dimensional (1D) peanut-shaped fullerene polymers (PSFPs) exhibit metallic properties, but their occurrence conditions are not yet clarified. By using the VASP (Vienna ab-initio simulation package) with density functional theory (DFT) and projector augmented wave (PAW) method, we have performed first-principles electronic structure calculations of four basic 1D PSFPs, T1, T2, T6, and T7 (the name of T1-T6 is the same as that of Wang et al. [9]) and two associated 1D PSFPs, T1SW1 and T6SW that are created by generalized Stone-Wales transformation (GSW) from T1 and T6. We found that almost regular six-membered rings connected throughout the tube are necessary to get metallic properties for the 1D PSFPs, although there may be several other conditions to expect metallic proper...

2011-01-01

27

Head and Neck Sentinel Lymph Node Biopsy: Current State of the Art  

UK PubMed Central (United Kingdom)

Sentinel node biopsy is an alternative to elective neck dissection for the management of T1/T2 oral and oro-pharyngeal squamous cell carcinomas and is also finding application to head and neck cancer...Full Text Available

28

GCN/MOA Gravitational Lensing Event Notices - GCN - NASA  

Science.gov (United States)

Jul 16, 2011 ... The standard filtering applies to all the existing distribution methods/media. ... needed to allow your data point(s) to be added to the MOA lightcurve. .... name="t1" value="0.00" unit="sigma" ucd="stat.snr" />

29

Breast Cancer Patients Treated Without Axillary Surgery  

UK PubMed Central (United Kingdom)

ObjectiveTo evaluate the impact of breast carcinoma (T1–2N0) surgery without axillary dissection on axillary and distant relapses, and to evaluate the usefulness of a panel...Full Text Available

2000-07-01

30

Total skin electron beam therapy followed by adjuvant psoralen/ultraviolet-a light in the management of patients with T1 and T2 cutaneous T-cell lymphoma (mycosis fungoides)  

International Nuclear Information System (INIS)

Purpose: Patients with mycosis fungoides [cutaneous T-cell lymphoma (CTCL)] may benefit from adjuvant therapy after completing total skin electron beam therapy (TSEBT). We report the results for (T1(T2)) CTCL patients treated with adjuvant oral psoralen plus ultraviolet light (PUVA) with respect to overall survival (OS), disease-free survival (DFS), salvage of recurrence, and toxicity. Methods and Materials: Between 1974 and 1993, TSEBT was administered to a total of 213 patients with CTCL. Records were reviewed retrospectively, and a total of 114 patients were identified as having T1 or T2 disease. Radiotherapy was provided via a 6-MeV linac to a total of 36 Gy, 1 Gy/day, 4 days/week, for 9 weeks. Beginning in 1988, patients were offered adjuvant PUVA within 2 months of completing TSEBT. This was started at 0.5-2 J/m"2, 1-2 treatments/week, with a taper over 3-6 months. Therapy then continued once per ...

1997-07-15

31

Synthesis and tissue distribution study of iodine-labeled benzyl- and xylylamines  

Energy Technology Data Exchange (ETDEWEB)

Four /sup 125/I labeled mono- and diamines were prepared and evaluated as potential brain-imaging agents. The diamines are analogues of the previously reported /sup 75/Se labeled diamines, which show high brain uptake and retention. All of the radioiodinated amines display high initial brain uptake in rats after intravenous injection (1.7-2.4% dose/organ). The xylylenediamines show prolonged brain retention (t1/2 approximately 18 h), which is desirable for brain imaging. In contrast, the benzylamine is rapidly cleared from brain tissue (t1/2 approximately 15 min).

1982-07-01

32

Computerized Tomography versus unenhanced and enhanced fast MRI sequences in the study of liver metastases: Qualitative and quantitative analyses  

International Nuclear Information System (INIS)

The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = ...

1997-01-01

33

Should coronary angiography be the gold standard? A study correlating thallium myocardial scintigraphy, translesional pressure gradient and percent stenosis  

International Nuclear Information System (INIS)

Coronary angiography provides anatomical information whereas thellium myocardial scintigraphy measures resistive tissue perfusion. Because of this fundamental difference. The authors question the validity of using coronary angiography as the gold standard to judge thellium myocardial scintigraphy. The authors studied 20 patients undergoing elective percutaneous coronary angioplasty who fulfilled the following criteria: (1) history of chest pain; (2) angiographically significant single vessel disease (>50% stenosis); (3) no prior myocardial infarction. All patients underwent maximal exercise thallium single photon emission computed tomography (T1-SPECT). Tl-SPECT was scored visually according to a 0 to 3 scale (0=absent uptake; 1=markedly decreased uptake; 2=minimally decreased uptake; 3=normal uptake). Translesional gradient and percent stenosis were measured before and after angioplasty. The authors found that significant linear ...

1985-06-02

34

NMR in highly correlated superconductors  

International Nuclear Information System (INIS)

Results of our systematic NMR study in high T_c cuprates are reviewed. The antiferromagnetic spin fluctuations (AFSF) decrease in the order of La_1_._8_5Sr_0_._1_5CuO_4. YBa_2Cu_3O_7 and Tl_2Ba_2CuO_6_+_y. 1/T_1 of "6"3Cu in the CuO_2 plane in the normal state follows essentially a Curie-Weiss law at high temperature and T_1T = const. law at low temperature. The temperature dependence of 1/T_1 and the Knight shift together with their impurity effect in the superconducting state strongly suggest d-wave pairing implying the AFSF to be responsible for the occurrence of superconductivity. From the NQR frequency measurement the density of Cu 3d and O 2p holes decreases and increases, respectively, in the order of La, Y and Tl compounds, which is consistent with the change of AFSF. The relation between T_c and #nu#_Q, and their pressure dependence suggest that there ...

1992-08-01

35

Genome lability in radiation-induced transformants of C3H 10T1/2 mouse fibroblasts  

Energy Technology Data Exchange (ETDEWEB)

We have been investigating radiation-induced neoplastic transformants of C3H 10T1/2 mouse fibroblasts for evidence of heritable changes. C3H 10T1/2 cells were treated with 8 Gy X rays. After approximately 8 weeks of culture, type II/III foci were isolated from the monolayer using cloning rings. Cell lines developed from these foci, and clones established from these cell lines, were examined for DNA content. The isolated focus-derived populations and derived clones often display aneuploidy and/or polyploidization. In one instance a clone (derived from a single cell) displayed multiple polyploidies. During passage the ploidy of many of the anomalous populations gradually reverted to the ploidy of the non-neoplastically transformed state. The morphological features associated with the neoplastic transformation event were nevertheless retained. The results demonstrate that exposure to radiation can induce, ...

1994-04-01

36

Gd-25 DTPA-MAb, a potential NMR contrast agent for MRI in the xenografted nude mouse: preliminary studies  

Energy Technology Data Exchange (ETDEWEB)

Monoclonal antibodies (MAbs) 19-9 and 73-3 specific for human colon adenocarcinoma were labelled with a high number of gadolinium atoms. Twenty five DTPA were chelated per MAb, with only slight loss of immunoreactivity. The NMR contrast agent Gd-25 DTPA-MAb 19-9 or 73-3 ((Gd) 17 mumole/kg, (MAb) 60 microM) was injected into nude mice bearing human colon adenocarcinoma (SW948). Tumors were removed 24 hr after injection and T1 was measured in vitro. T1 relaxation time varied according to MAb specificity against tumour targets; T1 decreased 20% for MAb 19-9 and MAb 73-3 with SW948 tumor. Imaging was performed with this model. Very good contrast was obtained 24 hr after Gd-25 DTPA-MAb injection.

1988-01-01

37

Synthesis and tissue distribution study of iodine-labeled benzyl- and xylylamines  

International Nuclear Information System (INIS)

Four "1"2"5I labeled mono- and diamines were prepared and evaluated as potential brain-imaging agents. The diamines are analogues of the previously reported "7"5Se labeled diamines, which show high brain uptake and retention. All of the radioiodinated amines display high initial brain uptake in rats after intravenous injection (1.7-2.4% dose/organ). The xylylenediamines show prolonged brain retention (t1/2 approximately 18 h), which is desirable for brain imaging. In contrast, the benzylamine is rapidly cleared from brain tissue (t1/2 approximately 15 min).

38

MRI findings of the brain in high-voltage electrical burn patient: case report  

Energy Technology Data Exchange (ETDEWEB)

We report the delayed sequelae arising in a case of electrical injury, reviewing the literature on the subject and focusing on the MRI findings of the brain. A 23-year-old male suffered burns to the left parietal scalp, both feet, and the anterior chest wall. Neurological symptoms and MRI abnormalities appeared 14 days after the insult and continued for about three months. T1-weight MR images demonstrated homogeneous hypointensity, while T2-weighted images depicted hyperintense finger-like projections. Contrast-enhanced T1-weighted images demonstrated strong band-like enhancement, indicating meningeal hyperemia. Follow-up MR imaging showed that the lesion had disappeared, indicating that the cerebral edema and meaningeal hyperemia were reversible.

2003-05-01

39

The Percus-Yevick theory is alive and well  

Science.gov (United States)

The pressure of a 6:12 fluid is obtained from the Percus-Yevick theory at the temperature kT/? = 1.35. The energy equation results are in excellent agreement with machine calculation results in contrast to the pressure and compressibility equation results. Present address: Diffusion Research Unit, The Australian National University, Canberra, ACT, Australia.

1970-01-01

40

Seeking nature of God in Big Bang T1 the secrets to the beginning of the universe could lie underground in Switzerland.  

CERN Multimedia

Joanna Geary joined a Birmingham University team of scientists working on the project in Geneva. Simond Hadley took the pictures. "The most exciting thing of all" says professor Peter Watkins with a smile, "is we have absolutely no idea what will happen until we switch it on."

2008-01-01

 
 
 
 
41

Risk analysis for the SNR-300 project. Pt. 1. Risikoorientierte Analyse zum SNR 300. T. 1  

Energy Technology Data Exchange (ETDEWEB)

The volume contains reports on plant technology, on systems organisation with the aim to minimize the risk (human error), on the problem of seismic risk, on core-disruptive accidents and on accident consequence models with different release categories and a comparison of the potential damage incurred. Mr. Webb; one of the authors, attempts to disprove the objections to his two earliest SNR statements by experts of Karlsruhe Nuclear Research Centre.

1982-01-01

42

Relationship between O6-alkylguanine-DNA alkyltransferase activity and N-methyl-N'-nitro-N-nitrosoguanidine-induced mutation, transformation, and cytotoxicity in C3H/10T1/2 cells expressing exogenous alkyltransferase genes.  

UK PubMed Central (United Kingdom)

While a great deal of evidence has directly implicated the importance of O6-alkylation of guanine in the mutagenicity of alkylating agents, evidence demonstrating the oncogenic potential of this lesion...Full Text Available

1992-12-01

43

MR imaging study on external hydrocephalus in infants: extracerebral space developmental and pathological enlargement  

International Nuclear Information System (INIS)

Objective: To analyze the characteristics of external hydrocephalus in infancy with MR imaging, and to explore the cause of accumulation of extracerebral fluid and the relation with brain development. Methods: Conventional magnetic resonance T_1 weighted imaging (T_1WI) and T_2 weighted imaging (T_2WI) were performed in 46 infants aged 2 years or younger with external hydrocephalus (EH), and the results were analyzed. They were divided into 7 age groups. The width of extractable space was measured on T_2WI and compared with normal standard. Results: EH mainly resulted from infection, subdural hematoma or subarachnoid hemorrhage, HIE, which were 67.4% (31/46 cases) of the cases; EH with unknown cause were 26.1% (12/46 cases). EH was mainly located at the foreside of cerebral convexity, of which 80.4% (37/46 cases )was predominantly in the subarachnoid space, 8.7% (4/46 cases) in subdural space, 10.9% was ...

2006-05-01

44

Experimental study of lipiodol ultra-fluid. On its signal intensity in MR imaging  

Energy Technology Data Exchange (ETDEWEB)

Lipiodol Ultra-Fluid (Lipiodol) is widely applied in the transcatheter arterial embolization (TAE). We studied signal intensity, the T1 relaxation time and the T2 relaxation time of Lipiodol itself using Siemens Magnetom H15-2 T (1.5 Tesla) and Magnetom M10 (1.0 Tesla). Lipiodol showed higher signal intensity than saline solution on the T1-weighted images (short TR, short TE technique in spin echo method). On the T2-weighted images (long TR, long TE technique in spin echo method), Lipiodol showed lower signal intensity than saline solution. The T1 relaxation time of Lipiodol, measured at 1.0 T, was 201 msec and 218 msec at 1.5 T. The T2 relaxation time of Lipiodol, measured at 1.0 T, was 127 msec; and 167 msec at 1.5 T. The signal intensity of Lipiodol at 1.0 T was higher than the intensity at 1.5 T. Shorter T1 ...

1988-11-01

45

Appearance of normal brain maturation on 1.5-T MR images  

International Nuclear Information System (INIS)

To investigate the pattern of normal white-matter maturation as demonstrated by high-field-strength MR imaging, 82 normal infants were examined using a 1.5-T unit with spin-echo T1-weighted and T2-weighted pulse sequences. The infants ranged in age from 4 days to 2 years. The scans were assessed for qualitative changes of white matter relative to gray matter and correlated with the patient's age in 14 anatomic areas of the brain. The MR images showed that changes of brain maturation occur in an orderly manner, commencing in the brain stem and progressing to the cerebellum and the cerebrum. Changes from brain myelination were seen earlier on T1-weighted images than on T2-weighted images, possibly because of T1 shortening by the components of the developing myelin sheaths. The later changes on the T2-weighted images correlated best with the development of ...

46

Thermal-resistant radiation sensing system using optical fiber for monitoring progress of chemical decontamination  

Energy Technology Data Exchange (ETDEWEB)

A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between ...

1999-07-01

47

Radiation damage studies on CrO_4"2"- doped alums  

International Nuclear Information System (INIS)

Radiation damage studies have been carried out on undoped and CrO_4"2"- doped potassium and ammonium alums. The optical absorption bands observed around 27100 and 36500 cm"-"1 before irradiation have been attributed to the transitions t_1 #-># e and t_1 #-># t_2, on the basis of Ball-hausen and Liehr scheme. On prolonged X-irradiation, these bands disappear in both the alums and three new bands seem to grow in ammonium alum while only two new bands could be seen in potassium alum. EPR studies at RT reveal that there are two lines at g = 2.004 and g = 2.010 in ammonium alum and only one line at g = 2.004 in potassium alum. Besides these two nearly isotropic lines, there is a set of lines around g = 1.95 in both the alums. Correlating the optical and EPR studies it is concluded that SO_3"- and O_3"- centres have formed on X-irradiation in ammonium alum while only SO_3"- seems to have formed in ...

48

Poncirin promotes osteoblast differentiation but inhibits adipocyte differentiation in mesenchymal stem cells.  

Science.gov (United States)

Poncirin, flavanone glycoside, isolated from the fruit of Poncirus trifoliata, has anti-bacterial and anti-inflammatory activities. In this study, the effects of poncirin on the differentiation of mesenchymal stem cells were investigated. The C3H10T1/2 mesenchymal stem cells and primary bone marrow mesenchymal stem cells were studied. In the C3H10T1/2 cells, poncirin prevented adipocyte differentiation, as demonstrated by inhibition of cytoplasm lipid droplet accumulation and peroxisome proliferator-activating receptor-? (PPAR-?) and CCAAT-enhancer-binding protein-? (C/EBP-?) mRNA expression. By contrast, poncirin enhanced the expression of the key osteogenic transcription factors, runt-related transcription factor 2 (Runx2) and transcriptional coactivator with PDZ-binding motif (TAZ). Poncirin also enhanced expression of the osteogenic marker genes including alkaline phosphatase (ALP) and osteocalcin ...

2011-05-01

49

Measurement of the "1"0"9Cd half-life  

International Nuclear Information System (INIS)

The half-life of "1"0"9Cd was measured by following the decay of sources from a radiochemically pure solution with two different measuring systems: an ionisation chamber and a high-purity germanium (HPGe) detector. The measurements were performed over a period of 3.6 years, i.e. about 2.8 half-lives of "1"0"9Cd. The resulting half-life values and detailed uncertainty budgets (k=1) are presented for both systems. The result obtained with the ionisation chamber, 462.36 (33) days, and the one obtained with the HPGe detector, 461.92 (76) days, are mutually consistent. The weighted mean of our measured values, T_1_/_2("1"0"9Cd)=462.29 (30) days, is consistent with the currently recommended values of 461.4 (12) days and 462.0 (3) days. From a set of selected experimental values published after 1970, a 'partially weighted mean' of T_1_/_2("1"0"9Cd)=462.36 (39) days was calculated. More measurements are needed ...

2011-05-01

50

MRI with pathogenic correlation of small renal cell carcinoma  

Energy Technology Data Exchange (ETDEWEB)

MRI, ultrasonography and angiography were performed on 24 cases with small renal cell carcinoma, and data were compared with pathological architecture type. An average diameter of cancer was 20.8 mm (10-30 mm). Each tumor was pathologically classified into four architecture types: alveolar type (15 cases), papillary type (5 cases), tubular type (3 cases) and cystic type (1 case). In comparison with renal cortex alveolar type renal cell carcinoma showed equal or low signal in T1-weighted images and equal or high signal in T2-weighted images. Papillary and tubular types showed high signal in T1-weighted images, and low signal in T2-weighted images. In alveolar type, many cases showed equal echo in ultrasonography and hypervascularity in angiography, and in papillary and tubular types, many cases showed high echo and hypovascularity. There were many cases with papillary type small cell carcinoma which ...

1999-11-01

51

MRI in pleural diseases  

International Nuclear Information System (INIS)

The MRI and CT appearances in 48 patients with histologically confirmed benign and malignant pleural abnormalities were compared retrospectively. Abnormal pleural changes were shown in 47 out of the 48 patients by high signal intensity of the pleura in T_2-weighted sequences and in contrast enhanced T_1-weighted sequences on MRI. CT showed abnormalities in 45 out of 48 patients. Delineation of pleural and pulmonary changes by CT was possible in 13 out of 23 cases, and pleural disease from effusions in 15 out of 28 cases. T_2-weighted MRI was successful in 14 out of 23 and 4 out of 28 cases, respectively. T_1-weighted images after contrast were successful in 20 out of 23 and 22 out of 28 cases, respectively. Indications of malignant pleural disease were the presence of mediastinal or circumferential involvement or involvement of the entire pleura, thickness of more than 10 mm and nodular changes. The ...

52

MR imaging of experimental intramuscular hemorrhage at 0. 02 T; Contrast enhancement with Gd-DOTA  

Energy Technology Data Exchange (ETDEWEB)

Intramuscular hermorrhage was induced by injecting autologous blood into the paraspinal muscle of 8 rabbits. In order to evaluate the time-dependent changes of hemorrhage observed on MRI, the animals were imaged at different stages of blood resolution at 0.02 tesla (T), and control examined with ultrasound using a 7.5 MHz linear transducer. Six inversion recovery sequences (TR=1 000 ms. TE=30 ms, and TI=18, 48, 148, 201, 302, and 398 ms) were used for the invivo calculation of T1 relaxation times. IR 1 000 (398)/30 imaging was performed before and after the Gd-DOTA administration. The hemorrhage was evident on MR images throughout the study, especially on the T2 weighted (SE 1 000/100) images. MRI showed the healing lesion longer than ultrasound. The T1 relaxation time increased during the time of resolution. Lesions on days 4 to 7 enhanced in intensity after the injection of Gd-DOTA. (orig.).

1990-09-01

53

MR imaging and MR cholangiopancreatography in the preoperative evaluation of hilar cholangiocarcinoma: correlation with surgical and pathologic findings  

International Nuclear Information System (INIS)

The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weighted images (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted vascular involvement ...

2008-10-01

54

MR findings of central nervous system involvement in acquired immunodeficiency syndrome patient : a report of two cases  

Energy Technology Data Exchange (ETDEWEB)

Central nervous system (CNS) manifestations in acquired immunodeficiency syndrome (AIDS) patients are an early and common feature. The spectrum of AIDS-related CNS diseases are encephalitis caused by the human immunodeficiency virus(HIV) itself, opportunistic infection, infarct and malignancy. We experienced two cases of CNS involvement in AIDS and they were serologically diagnosed as HIV encephalitis and CNS toxoplasmosis, respectively. In the case of the HIV encephalitis patient, brain MRI showed a non-enhancing lesion with high signal intensity on T2WI and low signal on T1WI and there was no mass effect on the right frontal lobe, periventricular white matter, splenium of the corpus callosum or bilateral basal ganglia. In the other case of CNS toxoplasmosis, MR showed multiple nodular and rim enhanced mass lesions in the right basal ganglia, thalamus and periventricular white matter, which were of low signal intensity on ...

1996-10-01

55

Intraoperative electron beam therapy and external photon beam therapy with lumpectomy as primary treatment for early breast cancer  

International Nuclear Information System (INIS)

Between 1984 and 1988, seven women with breast cancer were treated with intraoperative electron beam therapy (IOEBT). All patients were Caucasian. Patient age ranged from 37 to 62 (median 53) years. Histopathology was infiltrating duct carcinoma (6/7) or medullary carcinoma (1/7). Four tumors were staged T1 N0 MO, one T1 N1 MO, one T2 N1 MO, and one lesion was recurrent. At the time of primary lumpectomy or axillary node dissection, a dose of 10 or 15 Gy IOEBT was administered to the tumor bed with 6 or 9 MeV electrons through the lumpectomy wound. All patients received 45 or 50 Gy over five to six weeks with 6 MV photons to the breast and, in four patients, to the regional nodes. Three patients received adjuvant chemotherapy and tamoxifen. No post-operative complications were observed. All patients are alive as of August, 1989, with no evidence of recurrent disease. Excellent cosmesis is the rule. ...

56

High Magnetic Field NMR Studies of LiVGe$_2$O$_6$, a quasi 1-D Spin $S = 1$ System  

CERN Document Server

We report $^{7}$Li pulsed NMR measurements in polycrystalline and single crystal samples of the quasi one-dimensional S=1 antiferromagnet LiVGe$_2$O$_6$, whose AF transition temperature is $T_{\\text{N}}\\simeq 24.5$ K. The field ($B_0$) and temperature ($T$) ranges covered were 9-44.5 T and 1.7-300 K respectively. The measurements included NMR spectra, the spin-lattice relaxation rate ($T_1^{-1}$), and the spin-phase relaxation rate ($T_2^{-1}$), often as a function of the orientation of the field relative to the crystal axes. The spectra indicate an AF magnetic structure consistent with that obtained from neutron diffraction measurements, but with the moments aligned parallel to the c-axis. The spectra also provide the $T$-dependence of the AF order parameter and show that the transition is either second order or weakly first order. Both the spectra and the $T_1^{-1}$ data show that $B_0$ has at most ...

2001-01-01

57

Glycemic Control and Pregnancy Outcomes in Women with Type 1 Diabetes Mellitus Using Lispro Versus Regular Insulin: A Systematic Review and Meta-Analysis  

British Library Electronic Table of Contents (United Kingdom)

Abstract Aims: This study performed a systematic review and meta-analysis on glycemic control and pregnancy outcomes in women with type 1 diabetes mellitus (T1DM) treated with lispro (LP) versus regular insulin (RI) since before pregnancy. Methods: We performed a MEDLINE and EMBASE search. Abstracts (and full articles when appropriate) were reviewed by two independent researchers. Inclusion criteria were patients with T1DM, data on women treated with RI and LP since before pregnancy until delivery in the same article, at least five pregnancies in each group, and information on at least one pregnancy outcome. Quality assessment was performed using the Newcastle?Ottawa Quality Assessment Scale for cohort studies. Results: Outcome data were summarized with Revman version 5.0 (ims.cochrane.org...

2011-01-01

58

An estimation of the long-term clinical and economic benefits of insulin lispro in Type 1 diabetes in the UK  

British Library Electronic Table of Contents (United Kingdom)

Abstract Aims To determine the long-term health economic benefits associated with lispro vs. regular human insulin (RHI) in UK Type 1 diabetic (T1DM) patients using the previously published and validated CORE Diabetes Model. Methods A literature review designed to capture clinical benefits associated with lispro and T1DM cohort characteristics specific to UK was undertaken. Clinical benefits were derived from a Cochrane meta-analysis. The estimated difference (weighted mean) in glycated haemoglobin (HbA1c) was -0.1% (95% confidence interval -0.2 to 0.0%) for lispro vs. RHI. Severe hypoglycaemia rates for lispro and RHI were 21.8 and 46.1 events per 100 patient years, respectively. Costs and disutilities were accounted for severe hypoglycaemia rates. All costs were accounted in 2007 UK from...

2009-01-01

59

Uses of red mud based catalytic additives in hydrocracking. Pt. 1. Preparation and basic experiments. Einsatz von katalytischen Zusaetzen auf Rotmassebasis beim Hydrocracking. T. 1. Praeparation und Basisversuche  

Energy Technology Data Exchange (ETDEWEB)

This report contains two sections. In the first section a limited review is presented and the preparation of the red mud based additives is described. The additives are characterized by composition and their catalytic activity in hydrocracking is investigated in a batch autoclave under an initial hydrogen pressure of 12 MPa at 435 C and 30 min residence time. A quantitative characterization of the products is given. Comparisons between the red mud additives and coke respectively a commercial catalyst are made. (orig.)

1994-10-01

60

Usefulness of MRI in diagnosis of hepatocellular carcinoma (HCC)  

Energy Technology Data Exchange (ETDEWEB)

Sixty-six cases of histologically proven hepatocellular carcinomas (HCC) were studied by MRI. Detectability was better by MRI than by CT, especially in the tumor under 2 cm in diameter. The capsule was detected in all cases of HCC over 3 cm in diameter. The capsule was able to be diagnosed only by dynamic MRI study in some cases. High intensity on the T1-weighted image and iso or low intensity on the T2-weighted image suggested that the nodule was adenomatous hyperplasi (AH) or well differentiated HCC. MRI is concluded to be an essential modality in the diagnosis of HCC. (author).

1992-06-01

 
 
 
 
61

Nodular fasciitis: correlation of MRI findings and histopathology  

Energy Technology Data Exchange (ETDEWEB)

Objective: To compare the histopathology of nodular fasciitis (NF) with the magnetic resonance imaging (MRI) findings in order to evaluate the basis of the MR signal characteristics. Design and patients: Ten patients with NF, nine females and 1 male, with an age ranging from 13 to 58 years (mean 26.8 years) were studied. MRI findings, available in all 10 patients, were compared with the histopathology in nine patients, and an area-to-area comparative study of the whole specimen section histopathology and MRI was performed in two patients. Results: On the basis of an excisional biopsy or resection specimen, the nine lesions were classified into myxoid (n=4), cellular (n=3) and fibrous (n=2) subtypes. Four myxoid lesions with a subcutaneous location showed a homogeneous SI comparable with muscle on T1-weighted images, high SI on T2-weighted images, and had homogeneous enhancement. One cellular lesion presented with homogeneous, slightly higher SI ...

2002-03-01

62

NMR study of one-dimensional ionic conductor with hollandite-type structure (IV) Rb-priderite  

International Nuclear Information System (INIS)

Conduction properties of Rb"+ ion in Rb-Al-priderite and K"+ ion and Rb"+ ion in (K,Rb)-Al-priderite, were investigated by NMR using "2"7Al in the framework as a probe. Size effect was observed remarkably in the activation energies. Frequency dependence of T_1 in Rb-Al-priderite at a low temperature indicates that the relaxation behavior of "2"7Al in Rb-Al-priderite can be described by the continuum model. Barrier height distributions and 'attempt frequencies' in both samples obtained by a curve-fitting method are discussed in comparison with those of K-Al-priderite. (orig.).

1985-08-18

63

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

64

Investigations of the metallurgical characteristics of different cokes for cupola furnace operation. Pt. 1; Materials and methods. Untersuchung des metallurgischen Verhaltens unterschiedlicher Kokssorten fuer den Kupolofenbetrieb. T. 1; Voraussetzungen und untersuchte Kokse  

Energy Technology Data Exchange (ETDEWEB)

The report discusses: Combustion characteristics of various commercial cokes for cupola furnace operation; quality level of modern cokes; foundry coke, blast furnace coke, MB coke; characteristic data, e.g. grain size distribution, drum resistance, concentrations of water, carbon, sulphur, ash, and volatiles, reactivity; changes in coke quality during transport. (HS)

1993-06-14

65

IMAGING DIAGNOSIS-SYNOVIAL MYXOMA OF LUMBAR VERTEBRAE ARTICULAR PROCESS JOINT  

British Library Electronic Table of Contents (United Kingdom)

Magnetic resonance (MR) imaging and histopathology were used to diagnose an articular process synovial myxoma in a dog. On MR images, the tumor was characterized by distortion of the left L1-L2 articular process, widening of the articular process joint, and the presence of a mass contiguous with the synovium of the articular process that displaced the spinal cord. The tumor was T2-hyperintense, T1-hypointense, relative to muscle, and had mild contrast enhancement. The MR features of articular process synovial myxoma may be distinct from other diseases of the articular process joint.

2011-01-01

66

Diagnosis of peanut inhalation by MRI  

International Nuclear Information System (INIS)

We describe a 16-month-old boy presenting with stridor and fever. The chest X-ray suggested inhalation of a foreign body but here was no history of this. A high spot a T_1-weighted chest MRI was due to a peanut which was seen to have moved from the right main bronchus to the left inferior bronchus, between the two MRI studies. MRI can provide information on position and size of the peanut, the conditons of the surrounding tissues and may be also useful in treatment. We consider MRI to be a valuable new method for the diagnosis of peanut inhalation. (orig./GDG).

1992-01-01

67

Contrast factors in nuclear magnetic resonance imaging  

International Nuclear Information System (INIS)

In Nuclear Magnetic Resonance (NMR) imaging, contrast is dependent on the emission of radiofrequency waves by atomic nuclei, balanced by several parameters. The high information content of NMR images is due to the multiplicity of its parameters. However, this advantage introduces a difficulty in the interpretation of the contrast. There are three contrast parameters for each tissue: hydrogen nuclei density; relaxation time T1; relaxation time T2. Contrast may be enhanced towards any of these parameters by increasing the emission of radiowaves by atomic nuclei using particular pulse sequences.

1985-01-01

68

Synthesis, characterization, and evaluation of a novel bifunctional chelating agent for the lead isotopes "2"0"3Pb and "2"1"2Pb  

International Nuclear Information System (INIS)

Radioisotopes of Pb(II) have been of some interest in radioimmunotherapy and radioimmunoimaging (RII). However, the absence of a kinetically stable bifunctional chelating agent for Pb(II) has hampered its use for these applications. "2"0"3Pb (T_1_/_2=52.02 h) has application potential in RII, with a #gamma#-emission that is ideal for single photon emission computerized tomography, whereas "2"1"2Pb (T_1_/_2=10 h) is a source of highly cytotoxic #alpha#-particles via its decay to its "2"1"2Bi (T_1_/_2=60 min) daughter. The synthesis of the novel bifunctional chelating agent 2-(4-isothiocyanotobenzyl)-1,4,7,10-tetraaza-1,4,7,10-tetra-(2-carbamoyl methyl)-cyclododecane (4-NCS-Bz-TCMC) is reported herein. The Pb[TCMC]"2"+ complex was less labile to metal ion release than Pb[DOTA]"2"- at pH 3.5 and below in isotopic exchange experiments. In addition to increased ...

2000-01-01

69

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image nonuniformity variation with repetition and ...

2001-03-01

70

Modern visualization of the liver with MRI - current trends and future perspectives; Moderne Leberbildgebung mit der MRT - aktuelle Trends und Zukunft  

Energy Technology Data Exchange (ETDEWEB)

This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the liver can be expected with use of the 3T systems, but hitherto irrelevant problems must still be solved. Overall the ...

2004-12-01

71

The optimal path of piston motion for Otto cycle with linear phenomenological heat transfer law  

British Library Electronic Table of Contents (United Kingdom)

An Otto cycle engine with internal and external irreversibilities of friction and heat leakage, in which the heat transfer between the working fluid and the environment obeys linear phenomenological heat transfer law [q ?? ?(T ?1)], is studied in this paper. The optimal piston motion trajectory for maximizing the work output per cycle is derived for the fixed total cycle time and fuel consumed per cycle. Optimal control theory is applied to determine the optimal piston trajectories for the cases of with and without piston acceleration constraint on each stroke and the optimal distribution of the total cycle time among the strokes. The optimal piston motion with acceleration constraint for each stroke consists of three segments, including initial maximum acceleration and final maximum decel...

2009-01-01

72

The electroweak phase transition at m$_{H}$ $\\appprox$ m$_{W}$  

CERN Document Server

We study the finite temperature electroweak transition with non-perturbative lattice Monte Carlo simulations. We find that it is of first order, at least for Higgs masses up to 80 GeV. The critical temperature of the phase transition is found to be smaller than that determined by a 2-loop renormalization group improved effective potential. The jump of the order parameter at the critical temperature is considerably larger than the perturbative value. By comparing lattice data and perturbation theory, we demonstrate that the latter, for the computation of the vacuum expectation value of the Higgs field v(T) in the broken phase at given temperature, converges quite well, provided v(T)/T>1. An upper bound on the Higgs mass necessary for electroweak baryogenesis in the light of the lattice data is briefly discussed.

1994-01-01

73

Studies on the separation of Ag(I) during the recovery of Pu by ammonium plutonium(III) oxalate precipitation methodology  

International Nuclear Information System (INIS)

Studies on the separation of Ag(I) during the recovery of Pu from analytical waste generated during potentiometric determination of Pu using AgO as oxidant, by precipitation of Pu as ammonium plutonium (III) oxalate have shown that most of the Ag(I) is separated during the reduction of Pu to Pu(III) state by ascorbic acid. A decontamination factor of 54 was obtained. Additional a decontamination factor of 5.8 was obtained during the precipitation of Pu as ammonium plutonium (III) oxalate. The Ag content was determined by gamma spectrometry, using "1"1"1Ag as a tracer (T_1_/_2 7.45 d, #gamma# 342.1 keV) and HPGe as detector. The studies indicate that Ag is preferentially separated almost quantitatively during the recovery of plutonium, when acidity adjustment is done with NaOH instead of NH_3. (author)

2007-02-14

74

Staging of osteochondritis dissecans of the knee and ankle with MRI. Comparison with conventional radiography and arthroscopy  

International Nuclear Information System (INIS)

A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T_1- and T_2-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG).

75

Scoring of brain maturation in developmentally handicapped children with high-field MR imaging  

International Nuclear Information System (INIS)

A four-stage scoring system for brain maturation was established with MR imaging. First, gyration and myelination were analyzed in 50 anamnestically normal children (32-240 weeks postconceptional age). Subsequently 60 patients (same age range) with birth asphyxia, seizures, or developmental delays were evaluated analogously. T1- and T2-weighted images (500/30 and 3,000/120 [repetition time msec/echo time msec]) were obtained with a 2.35-T magnet in all children. Whereas gyration abnormalities were seen in some patients, all handicapped children presented with delayed myelination. In conclusion, prospective staging of brain development (gyration and myelination) is possible and is best obtained with T2-weighted images.

76

Role of MRI in the diagnostic evaluation of parotid diseases  

International Nuclear Information System (INIS)

MRI findings in 13 patients with monolateral parotid tumor were compared with US, sialographic and CT findings. MRI did not allow an accurate diagnosis in 2 patients with diffuse chronic parotitis. MRI was superior to CT in 1 case in defining the intraglandular site of the lesion, and in 2 patients in showing the extraglandular involvement. MRI proved to be superior to CT thanks to its contrast resolution and to multiplanar imaging. MRI high contrast resolution made it possible to demonstrate neoplastic lesions of 4 mm in diameter. The lesion has low signal intensity on T1-weighted images and high signal intensity on T2-weighted. Parotid tumors cannot be characterized by signal intensity alone: only morphology allows to discriminate between benign and malignant lesions. To conclude, US is a screening method, while MRI is helpful in detecting multifocal lesions and in evaluating the tumor extent.

1988-01-01

77

Reference values for X-ray diagnostic investigations. Some thoughts on the relation between expenditure and benefit; Referenzwerte fuer roentgendiagnostische Untersuchungen. T. 1. Ueberlegungen zur Verhaeltnismaessigkeit von Nutzen und Aufwand  

Energy Technology Data Exchange (ETDEWEB)

In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.) [German] Im ersten Teil des Aufsatzes werden die Definition von Referenzwerten in der radiologischen Diagnostik untersucht und die theoretischen und praktischen Probleme der Umsetzung des gesamten Konzepts eroertert. In diesem Zusammenhang werden auch der gegenwaertige Geraetebestand und die technischen Voraussetzungen zur Dosisermittlung beschrieben. Im zweiten Teil werden daraus Schlussfolgerungen gezogen und Vorschlaege zum weiteren Vorgehen gemacht. (orig.)

2000-07-01

78

Phytoplankton bloom in commercial shrimp ponds using green-water technology  

British Library Electronic Table of Contents (United Kingdom)

Phytoplankton community composition, density, and succession were studied in tropical commercial ponds with euryhaline tiger shrimp (Penaeus monodon Fabricius) using green-water technology at two different stocking densities [T1 10 post-larvae (PL) m?2 and T2 15 PL m?2] in one grow-out season (May?October 2005) in Leganes, Iloilo, Philippines. Weekly qualitative and quantitative analyses of phytoplankton were done along with physicochemical analyses of the pond waters. A total of 103 taxa belonging to nine different algal classes were observed. Of these classes, the Chlorophyceae, Cyanophyceae and Bacillariophyceae constituted the great bulk of the phytoplankton population. The two treatments did not show any significant differences in the growth pattern of phytoplankton over time and in t...

2007-01-01

79

Paroxysmal nocturnal hemoglobinuria: a case report of MR, CT findings  

Energy Technology Data Exchange (ETDEWEB)

Paroxysmal nocturnal hemoglobinuria (PNH) is a rare, acquired disease involving multiple hematopoietic cell lines. Characteristics of PNH are intrinsic hemolytic anemia, iron deficiency anemia and venous thrombosis. We report a case of PNH with characterostoc MR and CT findings. The signal intensity of renal cortex was lower than that of medulla on both T1-and T2-weighted MR imaging. On T2 weighted MR images, the liver showed very low signal intensity but the signal intensity of the spleen was normal. On precontrast CT the attenuation of renal cortex was higher than that of renal medulla and the attenuation of liver was higher than that of the spleen. These findings of MR imaging and CT were the result from the deposition of hemosiderin in the cells of proximal convoluted tubules and transfusional hemosiderosis of liver.

1995-10-15

80

Outcomes of extremely low risk prostate cancer following radical prostatectomy  

British Library Electronic Table of Contents (United Kingdom)

The optimal management of men with very favorable clinicopathological factors who develop biochemical recurrence (BCR) after radical prostatectomy (RP) has not been previously reported. Both local and systemic recurrences are unlikely in this cohort. This study examines their management and outcomes. Between October 2000 to March 2010, 1627 men underwent open RP by a single surgeon. In all, 448 (27.5%) met the following criteria for extremely low risk disease: preoperative PSA level <10?ng?ml?1, clinical stage T1c/T2a, Gleason score ?6, estimated cancer volume in the surgical specimen ?5% and no evidence for positive surgical margin. Undetectable PSA was defined as ?0.04?ng?ml?1. BCR was defined as PSA ?0.2?ng?ml&#...

2011-01-01

 
 
 
 
81

On the (in)feasibility of covered interest parity as a solution to the forward bias puzzle  

British Library Electronic Table of Contents (United Kingdom)

This paper examines Pippenger's (2011) proposed solution to the forward bias puzzle, which is based on the covered interest parity (CIP) condition. It is argued that the CIP-based approach does not solve this well known and long-standing puzzle in international finance in a meaningful way. Moreover, it is shown that empirical results from such an approach follow mechanically from the identity-like nature of the theory of covered interest parity, which, aside from small deviations due to transaction costs, is assumed to hold in all periods (as if it were an identity). We show that rather than leading to new insights, the simple reconfiguration of CIP to solve for the time t+1 spot exchange rate leads to tautological expressions that, when estimated, might appear to successfully explain the ...

2011-01-01

82

Observation and control of hepatic specimens with MRI and MRS; Beobachtung und Kontrolle von Fixiervorgaengen in Leberpraeparaten mittels MRT und MRS  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The purpose of this study was to observe the process of fixation in liver specimens non-invasively by means of magnetic resonance. The fixation process of several formaldehyde-containing solutions was monitored with MRI and MRS at two different temperatures. Materials and Methods: Liver specimens were conserved in aqueous fixative solutions containing formaldehyde concentrations of 0.7, 1.8, 4 and 7.2% and at different temperatures of 5 C and 20 C. MRI was performed with T1-, T2- and PD-weighted TSE sequences, a 2D FLASH-sequence with and without magnetization transfer, and a FISP 3D-sequence on a clinical 1.5 Tesla MR whole-body unit, and MRS with {sup 1}H-spectroscopic methods (STEAM-sequence) on a 3 Tesla MR whole-body unit. Results: The diffusion of formaldehyde into the tissue was best identified on PD- and T1-weighted images as a band under the liver surface with increasing thickness, ...

2004-04-01

83

Nuclear magnetic resonance study of La_3X compounds and related phases  

International Nuclear Information System (INIS)

Normal state nuclear magnetic resonance studies of the La_3In, La_3Tl compounds have been made in order to investigate the origin of the large temperature-dependent magnetic susceptibility. It is possible to analyse the different contributions to the susceptibility using Knight-shift and relaxation time T_1 measurements of In"1"1"5 and Tl"2"0"5 nuclei. The exchange enhancement of the spin-susceptibility chisub(pd) is of the same order as that found in A-15 compounds and the strong temperature-dependence of chi(T) is attributed to the presence of a peak in the electronic density of states near the Fermi level. The variation of the Knight-shift in the ternary alloys La_3Xsub(1-y)Xsub(y)sup(') is analogous to that observed in the corresponding La_3X phases, on the other hand the Knight-shift in the carbides La_3XC is temperature independent. (author).

84

Multimodal MRI assessment of damage and plasticity caused by status epilepticus in the rat brain  

British Library Electronic Table of Contents (United Kingdom)

Summary Status epilepticus or other brain-damaging insults launch a cascade of events that may lead to the development of epilepsy. MRI techniques available today, including T2- and T1-weighted imaging, functional MRI, manganese enhanced MRI (MEMRI), arterial spin labeling (ASL), diffusion tensor imaging (DTI), and phase imaging, can detect not only damage caused by status epilepticus but also plastic changes in the brain that occur in response to damage. Optimal balance between damage and recovery processes is a key for planning possible treatments, and noninvasive imaging has the potential to greatly facilitate this process and to make personalized treatment plans possible.

2011-01-01

85

Measurement of dose distributions of linear energy transfer in matter irradiated by fast neutrons  

Energy Technology Data Exchange (ETDEWEB)

A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.

1990-01-01

86

Imazalil-cyclomaltoheptaose (beta-cyclodextrin) inclusion complex: preparation by supercritical carbon dioxide and 13C CPMAS and 1H NMR characterization.  

Science.gov (United States)

An inclusion complex between imazalil (IMZ), a selected fungicide, and cyclomaltoheptaose (beta-cyclodextrin, betaCD) was obtained using supercritical fluid carbon dioxide. The best preparation conditions were determined, and the inclusion complex was investigated by means of 1H NMR spectroscopy in aqueous solution and 13C CPMAS NMR spectroscopy in the solid state. Information on the geometry of the betaCD/IMZ complex was obtained from ROESY spectroscopy, while the dynamics of the inclusion complex in the kilohertz range was obtained from the proton spin-lattice relaxation times in the rotating frame, T(1rho) (1H). PMID:14553984

2003-10-10

87

Half Life of "1"0"1Mo and "1"0"1Tc #beta#"--decay  

International Nuclear Information System (INIS)

In this work, the half-life of the "1"5"5Sm #beta#"- decay was determined using enriched "1"5"4Sm samples submitted to irradiation in the IEA-R1 reactor of IPEN; the activity of the samples were followed for 4-5 consecutive half lives using a 198 cm"3 HPGe detector. The data was corrected using a non paralizable dead time correction and fitted to an exponential decay function using a non linear fitting procedure developed on the MatLab platform. The resulting value--T_1_/_2 = 22.180(26) min--was compatible to the one found in the literature, with a lower uncertainty.

2010-05-21

88

Effects of pork/beef levels and various casings on quality properties of semi-dried jerky  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to investigate the effects of pork/beef levels and the casings on the quality properties of semi-dried jerky. The pork/beef levels in the four test formulations were as follows: T-1 (pork: beef=100:0), T-2 (95:5), T-3 (90:10), and T-4 (80:20). After tumbling for 30min with curing solution, the cured meats were stuffed into natural sheep casings, collagen casings, or cellulose casings, and then dried. The restructured jerky with cellulose casing had the lowest water content and the highest protein content, with no significant differences between various formulations. There were no significant differences among all formulations with regard to pH and total microbial counts, and jerky with cellulose casing had the lowest value of water activity. The processing yields ...

2008-01-01

89

Correlation of MRI and histomorphological findings in bone marrow oedema syndrome of the hip  

Energy Technology Data Exchange (ETDEWEB)

In 15 patients (16 hip joints) we found the clinical and radiological signs of BMOS. On T1-weighted MRI images areas of low signal intensity could be observed in the head, neck and the intertrochanteric region of the femur in various extensions. These areas showed a significant increase in signal intensity on the T2-weighted images. Because pain was resistant to conservative therapy all these patients were treated by core decompression of the femoral head in a prospective study. Bone cores were evaluated histologically using undecalcified sections and quantitative microradiography. The existence of intramedullary oedema in exactly the regions exhibiting the MRI pattern of bone marrow oedema was verified histologically; however, bone and marrow changes similar to those of early avascular necrosis (AVN) were also visible. (orig.)

1993-10-01

90

Copper-64 Radiopharmaceuticals for PET Imaging of Cancer: Advances in Preclinical and Clinical Research  

British Library Electronic Table of Contents (United Kingdom)

Summation Copper-64 (T1/2?=?12.7 hours; ?+, 0.653?MeV [17.8 %]; ??, 0.579?MeV [38.4 %]) has decay characteristics that allow for positron emission tomography (PET) imaging and targeted radiotherapy of cancer. The well-established coordination chemistry of copper allows for its reaction with a wide variety of chelator systems that can potentially be linked to peptides and other biologically relevant small molecules, antibodies, proteins, and nanoparticles. The 12.7-hours half-life of 64Cu provides the flexibility to image both smaller molecules and larger, slower clearing proteins and nanoparticles. In a practical sense, the radionuclide or the 64Cu-radiopharmaceuticals can be easily shipped for PET imaging studies at sites remote to the production facility. Due to the versatility of 64Cu, ...

2009-01-01

91

Comparison of fluid-dynamic modeling of flow with velocity-encoded MR imaging  

International Nuclear Information System (INIS)

This paper develops a fluid dynamic model using finite difference methods characterizing flow in phantoms simulating in vivo conditions and to compare those results with velocity encoded MR images. The phantom consisted of 1-inch (2.5-cm) tubing with semicircular insert and fluid with viscosity, T1, and T2 comparable to blood. Numeric solutions to Navier-Stokes equations for this system were obtained using finite difference methods, with velocity input function of zero at walls and parabolic at both ends. In resulting color raster (CR) images, color temperature represented velocity value. In velocity-encoded MR images acquired under the same flow conditions, phase is proportional to average velocity during application of flow-encoding gradients. Because these gradients are applied along one direction per acquisition, magnitude and direction of velocity are obtained.

1990-11-25

92

Characteristic features of intracranial meningiomas on magnetic resonance tomography  

International Nuclear Information System (INIS)

Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).

93

CH4/N2 Ratio as a Potential Alternative Geochemical Tool for Prediction of Thermal Maturity of Natural Gas in Tarim Basin  

British Library Electronic Table of Contents (United Kingdom)

In this context, the bulk ratio of CH4/N2 is examined as a potential alternative geochemical parameter for the assessment of thermal maturity of natural gas and compared to other previously published data. Open-system non-isothermal pyrolysis of low-mature coal from the Manjiaer sag, Tarim basin, yielded generation curves for methane and nitrogen. Analysis of the change of vitrinite reflectance indicates a two-stage process of thermal maturation with increasing temperatures. The relationship between Ro and pyrolysis temperature could be expressed by the following equations: Stage I: Ro = 0.0014T + 0.109, r = 0.9931(Ro Ro = 0.0067T -1.5855, r = 0.9996 (Ro > 0.6%). A kinetic interpretation of the characteristics of nitrogen and methane generation in humic coal during laboratory pyrolysis ind...

2008-01-01

94

A single-institution review of 157 patients presenting with benign and malignant tumors of the ampulla of Vater: Management and outcomes  

British Library Electronic Table of Contents (United Kingdom)

BackgroundAlthough benign ampullary tumors are removed endoscopically, due to their potential to progress to malignant disease, the favored treatment for adenocarcinoma is pancreaticoduodenectomy. We reviewed our institutions experience in order to identify which patients were at highest risk of disease progression following surgical resection, as well as evaluate whether localized T1 tumors are best treated by pancreaticoduodenectomy. MethodsWe retrospectively reviewed 157 patients who presented with an ampullary mass, from 2001 to 2010, and identified 51 with benign adenoma and 106 with adenocarcinoma. ResultsPatients with malignant tumors most often presented with larger tumors and jaundice, which alone was predictive of survival (OR = 67). Forty-five percent of patients with pathologic...

2011-01-01

95

Thallium-technetium subtraction parathyroid imaging in patients having previous parathyroid surgery  

International Nuclear Information System (INIS)

Parathyroid imaging based on the principle of differential uptakes of Tc-99m and T1-201 in the anterior neck to localize parathyroid (PT) disease has been reported with widely varying results. To evaluate the usefulness of this method, we have performed PT imaging on 47 patients prior to exploratory surgery for PT disease. Using pinhole collimation and digital acquisition, a 50k count image of the thyroid was obtained 20 minutes after injection of 1mCi99m Tc-pertechnetate. Then a lmCi dose of Tl-201 chloride was injected and a series of images acquired for 30 minutes at 30 sec/image. Raw data was spatially filtered and normalized by summing sufficient T1-201 images to equal the Tc-99m image scale of maximum cts/pixel. Image subtraction (Tl-Tc) gave the final PT image. Of 10 pts who had previous neck exploration, all had PT pathology accurately localized by preoperative scanning (7=single adenoma, ...

1985-06-02

96

Sequential changes in the femoral head after intracapsular fracture of the femoral neck. MRI findings  

International Nuclear Information System (INIS)

Authors obtained T1-weighted MRI images of the femoral head after fracture of the femoral neck and classified the signals into four patterns to investigate the sequential changes of the femoral head. The T1-weighted MRI images obtained initially after femoral neck fracture showed a normal pattern in 10 of the 15 hip joints studied. MRI images obtained subsequently still showed the normal signal pattern in eight of the 10 hip joints which had shown the normal pattern in the first MRI, while two of the 10 joints subsequently showed a band pattern. The joint with the homogeneous pattern in the first MRI subsequently showed a band pattern. Of the three joints with an inhomogeneous pattern in the first MRI, two joints showed a subsequent band pattern, and the other a normal pattern. The joints which showed a band pattern continued to show a similar band pattern. Eventually, all hip joints studied showed a ...

1998-07-01

97

Results of electron beam therapy using intra-oral cone for carcinoma of the oral tongue  

Energy Technology Data Exchange (ETDEWEB)

Retrospective analyses were performed to evaluate the therapeutic efficacy of intra-oral cone (IOC) radiation therapy for carcinoma of the oral tongue, especially about its faculty of local control and complications. Thirty-nine patients with squamous cell carcinoma of the oral tongue were treated with IOC radiation therapy alone or in combination with external irradiation. IOC radiation therapy was given not only for T1 and T2, but also for T3 tumors. Hypofractionation was used for IOC radiation therapy. The 2 year local control rates, including surgical salvage, for T1, T2, T3 and T4 were 100%, 73.3%, 40% and 0%, respectively. The 5 year actuarial survival rates for Stage I, II, III and IV were 100%, 65.3%, 35.4% and 0%, respectively. The incidences of radiation complications, i.e. soft tissue ulceration and osteoradionecrosis, were 42.9% and 2.9%, respectively. It is suggested that relatively high ...

1992-07-01

98

Relationship of DNA repair processes to mutagenesis and carcinogenesis in mammalian cells. Progress report, November 1, 1979-October 31, 1980  

International Nuclear Information System (INIS)

The objective of this research is to determine the role of DNA repair in mutagenesis and carcinogenesis in mammalian cells. Use of the host-cell reactivation viral suicide enrichment procedure was initiated in the isolation of repair-deficient mutants. Lightly mutagenized BHK cells were infected with irradiated Herpes simplex virus (HSV); several radiation-sensitive strains were isolated among the survivors of the infection. The characterization of these strains is progressing and the enrichments are continuing. That alterations in the frequency of mutation of C3H/10T 1/2 cells, occurring as a result of holding the cells in a confluent state following treatment with ethylmethane sulfonate, parallel the alterations in the frequency of neoplastic transformation was found. The repair capabilities of BHK cells were found to be intermediate in comparison to repair-proficient and -deficient human cells with regard to the reactivation of HSV treated ...

99

NMR studies of the partially disordered state in a triangular antiferromagnet UNi_4B  

International Nuclear Information System (INIS)

A triangular antiferromagnet UNi_4B experiences a partially disordered state, in which two-thirds of U 5f moments order in a vertex-like structure and one-third of U 5f moments remain paramagnetic. Magnetization and NMR measurements of UNi_4B have been performed to study the dynamical properties of U magnetic moments in the partially disordered state. The value of the effective moment above T_N derived from the fitting of the Curie-Weiss law suggests a significant crystal field splitting and the Kondo effect. The Weiss temperature was also estimated to be -28 K, which suggests that the exchange interaction is antiferromagnetic. Furthermore, the exchange interaction estimated from the relaxation rate T_1"-"1 above 50 K is 18 K, which is close to the Weiss temperature. These results suggest that the dominant interactions between U moments are antiferromagnetic in the basal plane. The relaxation rate ...

2007-04-11

100

MRI of normal fetal brain development  

International Nuclear Information System (INIS)

Normal fetal brain maturation can be studied by in vivo magnetic resonance imaging (MRI) from the 18th gestational week (GW) to term, and relies primarily on T2-weighted and diffusion-weighted (DW) sequences. These maturational changes must be interpreted with a knowledge of the histological background and the temporal course of the respective developmental steps. In addition, MR presentation of developing and transient structures must be considered. Signal changes associated with maturational processes can mainly be ascribed to the following changes in tissue composition and organization, which occur at the histological level: (1) a decrease in water content and increasing cell-density can be recognized as a shortening of T1- and T2-relaxation times, leading to increased T1-weighted and decreased T2-weighted intensity, respectively; (2) the arrangement of microanatomical structures to create a ...

2006-02-01

 
 
 
 
101

Hyperoxia-induced acute lung injury using a pig model. Correlation between MR imaging and histologic results  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to correlate MR imaging findings with pathology in experimental hyperoxia-induced acute lung injury, which has similar pathology to diffuse alveolar damage (DAD). Seventeen Yorkshire pigs were studied. These animals were exposed to more than 80% oxygen for 24, 48, 72, and 96 hours in a sealed cage. The lungs were removed and inflated with air infused through the trachea, and then examined by both MRI and high-resolution CT (HRCT). T1-weighted spin-echo (T1WSE), T2-weighted fast (T2WFSE), and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences were performed. Severity in MR findings and signal-to-noise ratios (SNR) on MR images were well correlated with pathological scores. CT values were also correlated well with pathologic scores. Abnormal SNR values were obtained from a pathological score of 5, whereas abnormal CT values were obtained from a ...

2001-06-01

102

Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy  

International Nuclear Information System (INIS)

High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm3) and accurate thermometry data (the PRFS method with a voxel ...

2008-11-21

103

Development of a geometrically accurate imaging protocol at 3 Tesla MRI for stereotactic radiosurgery treatment planning  

International Nuclear Information System (INIS)

The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI (mean ?0.6 mm; standard deviation ?0.3 mm). Mean stereotactic reference deviations ...

2010-11-21

104

Contribution to the experimental study of the polarized liquid helium-3; Contributions a l'etude experimentale de l'helium-3 liquide polarise  

Energy Technology Data Exchange (ETDEWEB)

Spin-polarized liquid helium-3 is prepared by laser optical pumping in low magnetic field and at room temperature, prior to fast liquefaction of the polarized sample. The use of a new helium-3 cryostat enabled us to obtain liquid helium-3 with polarization rates up to 25 % at well-stabilized temperatures (around 0.5 K). We could thereby study the effect of nuclear polarization on liquid-vapour equilibrium, and particularly on the saturated vapour pressure. Very sensitive capacitive gauges were developed. We estimated (to first order in M{sup 2}) the expected effects when the polarization M is suddenly destroyed. These effects were experimentally observed in helium-3/helium-4 mixtures, in pure helium-3, only a transient increase in pressure has been recorded. We then describe in a third part a preliminary experiment which aimed at determining the longitudinal relaxation time T1 in mixtures. Relaxation on the walls is efficiently reduced by a ...

1999-07-15

105

Comparison of radiationless decay processes in osmium and platinum porphyrins  

International Nuclear Information System (INIS)

Two osmium porphyrin complexes, Os(OEP)L_2 [OEP = octaethylporphin, L = py(pyridine) or NO], and PtOEP were investigated by picosecond laser spectroscopy with use of a double-beam, mode-locked Nd:glass system delivering 6-ps (fwhm) pulses at 527 nm with 1-2mJ/pulse. Time-resolved excited-state spectra were recorded from the time of photoexcitation to 5 ns after photoexcitation. The initial excited state, S_1, decayed in less than or equal to9 ps for the two osmium complexes and in less than or equal to15 ps for the platinum porphyrin. A second excited state, T_1, lived for 1, 9, and >50 ns respectively for Os(OEP)(py)_2, Os(OEP)(NO)_2, and PtOEP. The #DELTA#A spectra of the T_1 states of the osmium complexes were similar to those of previously reported (d/sub #pi#/,#pi#*) states for Os(OEP)(py)_2 and (#pi#,#pi#*) states for Os(OEP)(NO)_2. This finding supports prior assignments of these states on the ...

106

Incidence of lesions as described by MRI in focal epilepsy of frontal and temporal onset; Inzidenz kernspintomographisch erfassbarer Laesionen bei der Abklaerung fokaler Epilepsien frontalen und temporalen Ursprunges  

Energy Technology Data Exchange (ETDEWEB)

Aim: Today, MRI is an integral part of the presurgical evaluation of patients suffering from partial epilepsy. These patients frequently show focal morphological abnormalities with potential epileptogenic character and surgical resection of these lesions is associated with superior postsurgical outcome as to seizure frequency. Apart from easily detectable defects, such as post-traumatic lesions or cerebral infarction, as wide variety of mainly small abnormalities can be detected using MRI. Methods: In this study, 484 patients suffering from partial epilepsy of temporal or frontal onset were evaluated for the incidence of different lesions in this population. Results: All lesions found were included without evaluating their potential epileptogenicity, which remains to be proven using other procedures (EEG, SPECT, PET, etc.). Involvement of the hippocampal formation was a major finding in temporal lobe epilepsy, which could be detected as sclerosis (T2w-images), atrophy (T2w-TSE or ...

1997-09-01

107

[Molecular cloning and expression of an isotoxin gene, alpha-bungarotoxin, from Bungarus multicinctus].  

Science.gov (United States)

Abstract: Snake venom contains a number of small proteins,enzymes and other components,which displays a broad spectrum of biological activities. With the ability of specifically binding on acetylcholine acceptor, alpha-bungarotoxins are not only useful molecular probes in investigating the mechanism of neural signal transmission, but also potential pharmic preparations for neural disease treatment. In current research,cDNAs of Bungarus multicinutus venom gland were synthesized using SMART cDNA amplification kit and then, alpha-bungarotoxin genes were cloned and sequenced. Total of 20 clones were sequenced representing 14 isotoxin mRNAs of alpha-bungarotoxins. Among those clones, a novel isotoxin gene was subcloned into two expression plasmids, alpha-BgTX/pQE30a and alpha-BgTX/pGEX-4T-1, and transformed into E. coli. After inducing with IPTG, fused protein of GST-alpha-BgTX was successfully expressed at level of 30% gross proteins of bacteria. ...

2005-07-01

108

Theoretical investigation on quinoline-based platinum (II) complexes as efficient singlet oxygen photosensitizers in photodynamic therapy  

British Library Electronic Table of Contents (United Kingdom)

Geometry optimizations of the quinoline-based platinum (II) complexes (1-R, 2-R) and their related calculations on excited state energies, electronic absorption spectra and orbital populations have been carried out by the hybrid density functional theory (DFT) and its time-dependent approach (TD-DFT). The solvent effects on excitation energies are taken into account using the conductor-like polarizable continuum model (C-PCM). The red-shifted level of absorption bands, energy gaps between the singlet ground state (S1) and the first triplet excited state (T1) for each examined complex have been elaborated thoroughly as well. We find that the quinoline-8-thoil (ligand 2) induces much more significant red-shifted level than 8-hydroxyquinoline (ligand 1), and singlet-triplet splitting energy g...

2011-01-01

109

The diagnosis of inflammatory muscular and vascular conditions using MRT with STIR sequences  

International Nuclear Information System (INIS)

The role of MRT in the prebiopsy diagnosis of muscular and vascular inflammatory conditions was evaluated prospectively and an optimal method of examination was investigated. 92 patients with a suspected diagnosis of myositis (60 cases) or vasculitis (32 cases) were examined, in each case two extremities were studied using transverse T_1 and T_2 weighted SE sequences and double echo STIR sequences on a 0.5 Tesla (56 patients) or 1.5 Tesla magnet (36 patients; T5/S15 Gyroscan, Philips). The site of the biopsy depended on the MRT findings. In 41 patients the suspected diagnosis was confirmed histologically, in two patients an infective myositis was diagnosed on clinical grounds despite negative histology. MRT demonstrated muscle oedema in 86% of patients. There were negative findings after immuno-suppressive therapy (two patients), in focal myositis (3 out of 4 patients) and in one of 7 patients with untreated vasculitis. Amongst 49 patients in ...

110

The dependence of radiation hardening and embrittlement on irradiation temperature  

International Nuclear Information System (INIS)

Assessments of the hardening and embrittlement of pressure vessel steels and welds as a function of neutron dose use trend curves derived from surveillance programs and accelerated irradiation data. A temperature dependent factor is incorporated for assessing vessel locations operating at different temperatures. As hardening and embrittlement arise from the sum of matrix damage and copper impurity precipitation, the influence of irradiation temperature on each process needs to be established. For irradiations performed below #approx# 300 C recent data shows that the dose-dependent growth of copper precipitates ceases at a mean diameter of about 2 nm that also corresponds to peak hardening and embrittlement by copper. For doses beyond this peak copper dose the property-dependence on irradiation temperature can be identified with that of matrix damage alone. An analysis of several experiments on plate steels, performed at differing irradiation temperatures, has permitted the temperature ...

1994-06-20

111

T1 and T2 relaxivities of succimer-coated MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

International Nuclear Information System (INIS)

Superparamagnetic MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r2/r1, for MnFe2O4, Fe3O4 and CoFe2O4 were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T2 contrast agents for MRI.

2009-12-01

112

Study of iodine migration in zirconia using stable and radioactive ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The large uranium fission cross section leading to iodine and the behaviour of this element in the cladding tube during energy production and afterwards during waste storage is a crucial problem, especially for {sup 129}I which is a very long half-life isotope (T=1.59 x 10{sup 7} yr). Since a combined external and internal oxidation of the zircaloy cladding tube occurs during the reactor processing, iodine diffusion parameters in zirconia are needed. In order to obtain these data, stable iodine atoms were first introduced by ion implantation into zirconia with an energy of 200 keV and a dose equal to 8 x 10{sup 15} at cm{sup -2}. Diffusion profiles were measured using 3 MeV alpha-particle Rutherford backscattering spectrometry at each step of the annealing procedure between 700 C and 900 C. In such experiments a reduced iodine concentration was observed, which correlated to a diffusion-like process. Similar analysis has been performed using ...

1998-03-01

113

Structure and properties of a novel cobaltate La0.30CoO2  

British Library Electronic Table of Contents (United Kingdom)

The layered cobaltate La0.30CoO2 was prepared from NaxCoO2 precursor by a solid-state ionic exchange and was characterized by means of X-ray and neutron diffraction, magnetic, thermal and electric transport measurements. The compound consists of hexagonal sheets of edge-sharing CoO6 octahedra interleaved by lanthanum monolayers. Compared to Na+ in the parent system, the La3+ ions occupy only one-third of available sites, forming a 2-dimensional superstructure. The deviation from the ideal stoichiometry La1/3CoO2 introduces extra hole carriers into the diamagnetic LS Co3+ matrix making the sample Pauli paramagnetic. The temperature dependence of the electrical conductivity in La0.30CoO2 follows Mott's T?1/3 law up to about 400K, which is in contrast w...

2011-01-01

114

Soft tissue signal abnormality associated with eosinophilic granuloma. Correlation of MR imaging with pathologic findings  

Energy Technology Data Exchange (ETDEWEB)

Six patients with eosinophilic granuloma were studied retrospectively in order to correlate the MRI appearances with the pathology. Ages ranged from 2 years 6 months to 11 years. The bones involved were the humerus, ulna, radius, femur, clavicle and ilium. Plain films, MRI and pathology specimens were obtained. A lytic lesion with indistinct margins, endosteal erosions and periosteal reaction was seen in all cases on plain radiographs. Bone marrow signal was decreased on T1-weighted images and increased on T2-weighted images throughout the bony lesion in all cases. T2-weighted images showed extensive soft-tissue abnormalities suggesting inflammatory changes in four cases. In two cases abnormalities were limited. Extensive changes correlated histologically with an early phase lesion. Localized minor changes were associated with a mid-phase lesion. Inflammatory soft-tissue changes could be associated with eosinophilic granuloma. The size of the ...

1994-09-01

115

Pre-operative MRI of anorectal anomalies in the newborn period  

Energy Technology Data Exchange (ETDEWEB)

Nine infants (six boys, three girls) with anorectal anomalies were examined in the immediate newborn period, prior to corrective surgery, with MRI. Three high, one intermediate and five low anomalies were found at MRI - one patient with a `low` lesion was subsequently found at surgery 2 months later to have a high anorectal anomaly. This infant had passed meconium per urethram soon after the MRI study, prompting the need for a protective colostomy and stressing the importance of a thorough clinical examination of babies with anorectal malformations. The MRI results and findings at surgery were in agreement in all other patients (n=8). Hydronephrosis was evident in two and renal agenesis in one patient. Sacrococcygeal hypoplasia was found in two and two hemivertebrae in one infant. No spinal cord lesion was identified. One fistula was evident on MRI but four were later found at surgery. Uniformly hyperintense T1 signal meconium was seen in all ...

1995-11-01

116

On the temperature dependence of the magnetic excitations  

International Nuclear Information System (INIS)

We compare experimental data for temperature dependence of the magnetic order parameter and the magnetic excitations (spin waves) in materials with a quenched orbital moment and a well-defined spin quantum number. It is observed that the thermal decrease of the two quantities proceeds according to the same analytical function of the type y(T)=1-cT"#epsilon# with an identical exponent #epsilon#. This power function applies not only asymptotically for T->0 but holds over a wide temperature range. The exponent #epsilon# is universal, i.e. independent of spin order type and lattice symmetry and depends only on the dimensionality of the relevant interactions and on whether the spin quantum number is integer or half-integer. The different T"#epsilon# functions are identified as representations of stable universality classes. The fact that order parameter and magnetic excitations follow the same T"#epsilon# function shows that the two quantities ...

2005-07-15

117

New high-spin isomer and quasiparticle-vibration coupling in "1"8"7Ir  

International Nuclear Information System (INIS)

The high-spin structure of the Z=77 nucleus "1"8"7Ir has been studied using the fusion-evaporation reaction "1"8"6W("7Li6n) at a beam energy of 59 MeV. The excitation scheme of this nucleus has been extended by more than 110 new states, including extensions of all previously established rotational bands. The band crossing region of the h_9_/_2 negative-parity yrast band has been revised and new intrinsic high-K states have been identified. In particular, a 29/2"- isomeric state [T_1_/_2=1.8(5)#mu#s] at an excitation energy of 2487 keV has been observed for the first time, and on top of it, a rich level scheme reaching up to spin (59/2"-) and excitation energies around 7 MeV has been established.

2010-05-01

118

NMR studies of Borrelia burgdorferi OspA, a 28 kDa protein containing a single-layer #beta#-sheet  

International Nuclear Information System (INIS)

The crystal structure of outer surface protein A (OspA) from Borrelia burgdorferi contains a single-layer #beta#-sheet connecting the N- and C-terminal globular domains. The central #beta#-sheet consists largely of polar amino acids and it is solvent-exposed on both faces, which so far appears to be unique among known protein structures. We have accomplished nearly complete backbone H, C and N and C";/H"#beta# assignments of OspA (28 kDa) using standard triple resonance techniques without perdeuteration. This was made possible by recording spectra at a high temperature (45 "oC ). The chemical shift index and "1"5N T_1/T_2 ratios show that both the secondary structure and the global conformation of OspA in solution are similar to the crystal structure, suggesting that the unique central #beta#-sheet is fairly rigid.

1998-05-01

119

Mass Production of 64Cu with 64Ni(p,n)64Cu Nuclear Reaction and Target Material Recycling  

International Nuclear Information System (INIS)

64Cu (T1/2=12.7h, ?- decay: 40%, ?+ decay: 19%, E.C. decay: 41%) is one of the most useful radioisotope in the nuclear medicine due to its multiple decay mode and the intermediate half-life. Several nuclear reaction, i.e., 64Ni(p,n)64Cu, 68Zn(p,?n)64Cu and 64Ni(d,2n)64Cu have been investigated for production. The highest could be obtained with proton irradiation on the enriched 64Ni target. For mass and routine production, the 64Ni target fabrication using electroplating, the reliable chemical separation of 64Cu from the irradiated 64Ni target and the effective recovery process for the recycling of very expensive enriched material ($20,000/g) and so forth are absolutely necessary to be established. In this work, we report our mass production method of 64Cu with 64Ni and Cyclone-30 accelerator

2009-05-01

120

Magnetism in "3He  

International Nuclear Information System (INIS)

The nuclear magnetic susceptibility, #chi#, of "3He is seen to nearly obey a pure Curie Law, #chi# = C/T, over the temperature range 0.5 mK < T < 2 K when contained in the 20#ALPHA#, multiply connected pores of Vycor glass at low external pressure. Raising the external pressure to 5 bar (1 bar 100 kPa) causes the susceptibility to obey the Curie-Weiss law, #chi# = C' /T - #THETA# whose #THETA# = 0.3 mK. The longitudinal relaxation time, T_1, varies monotonically with T between 17 and 90 ms at both pressures. At 5 bar, the transverse relaxation time T_2*, is nearly temperature independent (about 600 #mu#s) above 2 mK. Below 2 mK, T_2* drops precipitously. Preliminary measurements indicate that the magnetism is produced by atoms that can flow through the pores of the Vycor glass. (10 refs., fig.).

1986-10-01

 
 
 
 
121

Magnetic resonance imaging of the hip with a pelvic phased-array surface coil: a technical note  

Energy Technology Data Exchange (ETDEWEB)

Objective. The aim of this study was to assess the capability of high-resolution images obtained with a commercially available pelvic phased-array surface coil to demonstrate normal hip anatomy. Design. We retrospectively analyzed the oblique coronal magnetic resonance (MR) images of hips of 36 consecutive patients acquired on a 1.5-T clinical imager using a pelvic phased-array coil as a receiver, a 16-20 cm field of view, and 5 mm slice thickness. Patients. Thirty-six patients were studied, age 15-81 years. There were 20 males and 16 females. Results and conclusions. The articular cartilage, cortex, superior labrum, and iliofemoral ligament were well visualized on proton density weighted fat saturation (PDF) images. The femoral and obturator vessels, obturator nerve, and various muscles were easily seen on T1-weighted images. High-resolution imaging of the hip is achievable in a reasonable amount of time using newer phased-array surface coils ...

1998-02-01

122

Magnetic resonance appearance of peripheral nerve sheath tumors  

International Nuclear Information System (INIS)

Magnetic resonance imaging (MRI) was used to evaluate 22 histological proven peripheral nerve sheath tumors, approximately two-thirds of which arose in the lower extremity. The histologic distribution was as follows: 12 schwannomas, 7 neurofibromas, and 3 malignant peripheral nerve sheath tumors (2 of which occurred in patients with neurofibromatosis). Most lesions demonstrated an intermediate to moderately bright signal on T_1-weighted images and were minimally inhomogeneous. All lesions were moderately bright on T_2-weighted images, again with variable inhomogeneity. The extent of the tumor was best assessed on proton-density- and T_2-weighted images. Smooth margins were noted in 19 lesions. Of the 3 remaining lesions, 2 were malignant (but had been subjected to biopsy prior to MRI), and the other lesion was a plexiform neurofibroma. MRI accurately determined the relationship between the lesions and the adjacent neurovascular structures and ...

123

MRT of the abdomen in combination with enteroclysis in Crohn disease with oral and intravenous Gd-DTPA  

International Nuclear Information System (INIS)

60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A brilliant MR-tomographic imaging of the small bowel is possible under the condition, that the small bowel contrast is optimal. The ...

124

MRT in differentiation between tumour and implant material in the postoperative sella  

International Nuclear Information System (INIS)

MRT criteria have been developed to distinguish between tumour and implant material following examination of 50 patients who had transsphenoidal hypophysectomies for tumours. Judgements were based on the postoperative hormonal status and the operation notes. Following contrast injection of Gd-DTPA and using T_1 weighted spin-echo sequences, implant material appeared as sandwich-like, linear or circular structures. Residual recurrent tumour produced homogenous or non-homogenous aspects without marginal enhancement in 84% of cases. Postoperative displacement of the infundibulum to the opposite side was observed in 73% of patients with tumour remnants. Sensitivity of MRT was 70%, specificity 95%. There was a positive predictive value of 94% and a negative predictive value of 72% with an accuracy of 81%. This provides assistance in differentiating between tumour remnants and implant material. MRT is recommended as a method of examination for ...

125

MRI with SPIR sequences of optic nerve lesions; Utilita' delle sequenze 'Selective Partial Inversion Recover' (SPIR) nelle mallattie del nervo ottico  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the yield of SPIR sequences with fat suppression in the diagnosis of optic nerve lesions. T1 and T2 weighted fat suppressed SPIR imaging of the optic nerve improves anatomical definition, lesion detection and characterization in optic nerve conditions. [Italian] L'articolo analizza i vantaggi ricavabili dall'utilizzazione delle sequenze SPIR nella documentazione del decorso del nervo ottico e delle sue alterazioni nei pazienti con sospetto clinico e strumentale di malattia retrobulbare. L'utilizzo delle sequenze SPIR consente ottimale visualizzazione del nervo ottico e delle sue eventuali alterazioni senza gli artefatti che limitavano la qualita' delle immagini nelle prime sequenze RM con soppressione del segnale del grasso.

1999-04-01

126

MR imaging of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Magnetic resonance (MR) images of 18 cases of hilar cholangiocarcinoma were evaluated to compare the effectiveness of Gd-DTPA with that of high dose contrast enhancement computed tomography (HCE-CT) in detecting the primary tumor. The primary tumor was demonstrated as having slightly low intensity compared with liver parenchyma and high intensity compared with the delated bile duct on T1-weighted images. In contrast, MRI using Gd-DTPA, which was carried out in five cases, revealed intense enhancement of the tumor. As the differentiation between cholangiocarcinoma and dilated bile duct was difficult, it was concluded that the use of Gd-DTPA improves the efficacy of MRI in diagnosing cholangiocarcinoma. Gd-DTPA was also effective in differentiating the growth pattern of the tumor: the infiltrating type was demonstrated as thickening of the wall of the bile duct, the polypoid type as a soft tissue mass in the bile duct. Contrast MRI study is ...

127

MR imaging of bone marrow with gradient echo sequences. Pt. 1. Contrast conditions of phase-identical and opposed-phase gradient echo sequences. Kernspintomographische Screeninguntersuchungen des Knochenmarkes mit Gradientenecho-Sequenzen. T. 1. Kontrastverhaeltnisse phasenidentischer und phasenverschobener Gradientenecho-Sequenzen. Untersuchungen von Probanden und pathologisch-anatomischen Praeparaten  

Energy Technology Data Exchange (ETDEWEB)

Anatomical specimens and normal persons were studied by gradient echo MR imaging to determine the influence of different echo times (TE) on bone marrow contrast. First of all, six normal persons were studied to determine specific echo times for in-phase and opposed-phase states. Using different sequences bone marrow contrast in isolated femoral bones was determined and compared to results of pathological exams. Red bone marrow had no signal on opposed-phase images; contrast between red and yellow marrow was higher on opposed-phase than on in-phase images. Bone marrow lesions can be expected to be visualised with high signal on opposed-phase images; this technique should be especially suited for MR imaging of bone marrow. (orig.).

1991-06-01

128

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil  

International Nuclear Information System (INIS)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: ...

129

Isothermal, total strain-controlled cyclic deformation of GGG-60 at temperatures of 20 C {<=}T {<=}500 C. Pt. 1; Isotherme totaldehnungskontrollierte Wechselverformung von GGG-60 im Temperaturbereich 20 C {<=}T {<=}500 C. T. 1  

Energy Technology Data Exchange (ETDEWEB)

The paper examines the influence of various total strain amplitudes and mean strains on the cyclic deformation processes in GGG-60 at temperatures of 20 C, 350 C, and 500 C ,the total strain amplitudes being varied between 1.0 permille {<=}{epsilon}{sub a,t}{<=}3.8 permille , and the mean strains between -4.0 permille {<=}{epsilon}{sub m,t}{<=}4.0 permille . - [Deutsch] In der Arbeit wird der Einfluss unterschiedlicher Totaldehnungsamplituden und Mitteldehnungen auf das Wechselverformungsverhalten von GGG-60 bei Temperaturen von 20 C, 350 C und 500 C untersucht. Dabei werden die Totaldehnungsamplituden zwischen 1,0 permille {<=} {epsilon}{sub a,t} {<=} 3,8 permille und die Mitteldehnungen zwischen -4,0 permille {<=} {epsilon}{sub m,t} {<=} 4,0 permille variiert. (orig./MM)

1995-01-01

130

Intracranial tuberculoma: MR imaging  

International Nuclear Information System (INIS)

MR studies of 6 patients with intracranial tuberculoma are reviewed. All patients also underwent CT scans which showed hypo- or isodense lesions with abnormal enhancement following contrast administration. MR showed lesions with prolongation of the T1 relaxation time in every case. On the T2-weighted sequences, the signal properties of the tuberculoma varied according to the stage of evolution of the lesion. Incipient tuberculomas appeared as scattered areas of hypointensity surrounded by edema. Mature tuberculomas were composed of a dark necrotic center surrounded by an isointense capsule which was, in turn, surrounded by edema. In one patient, the center of the lesion was hyperintense probably because of liquefaction and pus formation (tuberculous abscess). While both, CT and MR, were equally sensitive in visualizing the intracranial tuberculoma in every patient, MR was slightly superior in demonstrating the extent of the lesion, especially ...

1988-11-01

131

Heating and ventilation concept for a better room climate and for energy conservation. Part 1; Heiz- und Lueftungskonzept fuer besseres Raumklima und Energieeinsparung. T. 1  

Energy Technology Data Exchange (ETDEWEB)

Ventilation, cooling and illumination of modern high-rise office buildings with high-quality thermal insulation (average k-value 1.0 W/m12K) and high loads from office machinery (up to 20 W/m12 and beyond) are problematic even for modern facility management systems, with consequences for the building shell, heating system, and window ventilation. [Deutsch] Die Lueftung, Kuehlung und Beleuchtung moderner Buerohochbauten mit extremer Waermedaemmung (mittlerer K-Wert 1,0 W/m{sup 2}K) und hohen Bueromaschinenlasten (bis zu 20 W/m{sup 2} und mehr) verursachen auch heute noch erhebliche Probleme, obwohl die technische Gebaeudeausruestung weiterentwickelt wurde. Dies zeigt sich vor allem bei der Fassadenausbildung der Heizung und Fensterlueftung. (orig.)

1999-11-01

132

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors ...

2000-05-01

133

Full-Rate Full-Diversity Achieving MIMO Precoding with Partial CSIT  

CERN Document Server

In this paper, we consider a $n_t\\times n_r$ multiple-input multiple-output (MIMO) channel subjected to block fading. Reliability (in terms of achieved diversity order) and rate (in number of symbols transmitted per channel use) are of interest in such channels. We propose a new precoding scheme which achieves both full diversity ($n_tn_r$th order diversity) as well as full rate ($n_t$ symbols per channel use) using partial channel state information at the transmitter (CSIT), applicable in MIMO systems including $n_rt-1$ angle parameter values, compared to $2n_tn_r$ real coefficients in case of full CSIT. Error rate performance results for $3\\times 1$, ...

2011-01-01

134

Free air flows for the removal of pollutants from car parks; Air-conditioning systems without sheet metal ducts as an alternative to transverse ventilation with sheet-metal ducts. Pt. 1. Freie Luftstroemungen entsorgen Parkraeume; RLT-Anlagen ohne Blechkanaele als Alternative zur Querlueftung mit Blechkanaelen. T. 1  

Energy Technology Data Exchange (ETDEWEB)

In car parks of considerable length, the removal of exhaust emissions, is carried out by air-conditioning systems mainly through transverse ventilation over short routes. The required air-conditioning ducts frequently produce a reduction in the available parking space simply due to their presence, resulting in restrictive effects on the level of acceptance by the users. In such cases, remedial action can be taken by creating ductless longitudinal ventilation. Depending on the required room air quality in the zones with the highest level of pollution, the volumetric flows for longitudinal disposal are no greater than those for conventional transverse ventilation. In conjunction with architecturally clear and positive lighting designs, clearly laid out car parks with a friendly atmosphere can be created which the user will be pleased to accept. (orig./BWI)

1994-03-01

135

Dura thickening adjacent to intracranial tumors on MRI. Histologically correlation  

International Nuclear Information System (INIS)

Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T_2-weighted spin echo (SE) images as well as T_1-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 meningiomas and 15 of 19 metastases without dural thickening at the tumor base also ...

136

Diagnostic value of MRI for hepatic hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To investigate the value of MRI in the diagnosis of hepatic hilar cholangiocarcinoma. Methods: Sixty-four patients with hepatic hilar cholangiocarcinomas confirmed by surgery or pathology underwent MRI using a 1.5-T superconductive MR system including conventional unenhanced MRI, MRCP and dynamic contrast-enhanced MRI with Gd-DTPA. Results: Dilatation of the intrahepatic biliary tree with narrowing, occlusion or filling defects in the hepatic hilar bile ducts was noted in all 64 cases. Unenhanced MR[ showed T_1- and T_2-hyperintense hilar masses in 42 patients and was normal in the remaining 22 patients. The hilar masses demonstrated slow, progressive and delayed enhancement patterns. There was enhancement of the thickened bile duct wall with luminal narrowing in the 22 patients without hilar masses. Conclusion: The characteristic MRI findings of enhancing hepatic hilar mass and bile duct wall thickening together with MRCP are ...

2010-02-01

137

Computational Models of Certain Hyperspaces of Quasi-metric Spaces  

CERN Document Server

In this paper, for a given sequentially Yoneda-complete T_1 quasi-metric space (X,d), the domain theoretic models of the hyperspace K_0(X) of nonempty compact subsets of (X,d) are studied. To this end, the $\\omega$-Plotkin domain of the space of formal balls BX, denoted by CBX is considered. This domain is given as the chain completion of the set of all finite subsets of BX with respect to the Egli-Milner relation. Further, a map $\\phi:K_0(X)\\rightarrow CBX$ is established and proved that it is an embedding whenever K_0(X) is equipped with the Vietoris topology and respectively CBX with the Scott topology. Moreover, if any compact subset of (X,d) is d^{-1}-precompact, \\phi is an embedding with respect to the topology of Hausdorff quasi-metric H_d on K_0(X). Therefore, it is concluded that (CBX,\\sqsubseteq,\\phi) is an $\\omega$-computational model for the hyperspace K_0(X) endowed with the Vietoris and respectively the Hausdorff topology. ...

2011-01-01

138

Comparison of contrast-enhanced flash and turbo-flash with conventional spin-echo sequences as a basis for morphologocal MR imaging for planning high-precision radiotherapy of intracranial brain tumors. Comparison of FLASH-, turbo-FLASH and SE-sequences; Morphologische MR-Bildgebung mit T1-gewichteten Sequenzen zur radiotherapeutischen Zielvolumendefinition von intrakraniellen Tumoren. Vergleich von FLASH-, Turbo-FLASH- und SE-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Introduction: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. Methods: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the signal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. Results: The signal- and contrast-to-noise ratios were significantly (P<0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 ...

1997-03-01

139

CT and MRI characteristica of tumours of the temporal bone and the cerebello-pontine angle; CT und MRT tumoroeser Veraenderungen des Schlaefenbeins  

Energy Technology Data Exchange (ETDEWEB)

Tumours lesions of the temporal bone and of the cerebello-pontine angle are rare.This tumours can be separated into benign and malignant lesions. In this paper the CT and MRI characteristica of tumours of the temporal bone and the cerebello-pontane angle will be demonstrated. High resolution CT (HRCT) as usually performed in the axial plane are using a high resolution bone window level setting, coronal planes are the reconstructed from the axial data set or will be obtained directly. With the MRI FLAIR sequence in the axial plane the whole brain will be scanned either to depict or exclude a tumour invasion into the brain. After this,T2-weighted fast spin echo sequences or fatsuppressed inversion recovery sequences in high resolution technique in the axial plane will be obtained from the temporal bone and axial T1-weighted spinecho sequences before and after the intravenous application of contrast material will be obtained of this region. ...

2003-03-01

140

Bevacizumab as a treatment option for radiation-induced cerebral necrosis  

International Nuclear Information System (INIS)

Radiation necrosis of normal CNS tissue represents one of the main risk factors of brain irradiation, occurring more frequently and earlier at higher total doses and higher doses per fraction. At present, it is believed that the necrosis results due to increasing capillary permeability caused by cytokine release leading to extracellular edema. This process is sustained by endothelial dysfunction, tissue hypoxia, and subsequent necrosis. Consequently, blocking the vascular endothelial growth factor (VEGF) at an early stage could be an option to reduce the development of radiation necrosis by decreasing the vascular permeability. This might help to reverse the pathological mechanisms, improve the symptoms and prevent further progression. A patient with radiation-induced necrosis was treated with an anti-VEGF antibody (bevacizumab), in whom neurologic signs and symptoms improved in accordance with a decrease in T1-weighted fluid-attenuated ...

2011-02-01

 
 
 
 
141

Autoradiographic and small-animal PET comparisons between 18F-FMISO, 18F-FDG, 18F-FLT and the hypoxic selective 64Cu-ATSM in a rodent model of cancer  

British Library Electronic Table of Contents (United Kingdom)

IntroductionCopper(II)-diacetyl-bis(N4-methylthiosemicarbazone), or Cu-ATSM, a hypoxia imaging agent, has been shown to be predictive of response to traditional cancer therapies in patients with a wide range of tumors. It is known that the environment of the tumor results in a myriad of physiological consequences, including hypoxia, alterations in metabolism and proliferation. In an effort to better characterize the relationships between Cu-ATSM and other prominent radiopharmaceuticals, this current study was undertaken to compare the regional distribution of 64Cu-ATSM with [18F]fluoromisonidazole (18F-FMISO), [18F]fluoro-2-deoxy-d-glucose (18F-FDG) and [18F]fluorothymidine (18F-FLT) in 9L tumors.MethodsTaking advantage of the different half-life of 18F (t1/2=110 min) in comparison to 64Cu...

2008-01-01

142

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided into 16 fine clusters. The final tissue classifications were presented as color-coded anatomically-mapped images and as two and ...

143

An availability of brain magnetic resonance imaging (MRI) in the early diagnosis of latent hepatic encephalopathy  

Energy Technology Data Exchange (ETDEWEB)

Brain MRI was carried out in patients with chronic liver diseases. No abnormal findings were recognized in patients with chronic viral hepatitis, while 59.2% of cirrhotics showed a symmetrically strong signal in basal ganglia on T1 weighted image in MRI. This finding significantly related with lowered Fischer`s ratio of serum amino acid, increased levels of serum phenylalanine, tyrosine and hyaluronic acid, prolonged prothrombin time and decreased platelet counts in the peripheral blood. Overt hepatic encephalopathy was observed in 6 of 34 patients with the strong signal in MRI during follow-up period, while none of patients without that finding developed hepatic encephalopathy. These results have indicated that the strong signal in basal ganglia on MRI appears in cirrhotic patients with severe liver dysfunction, and it is an useful index in the early diagnosis of latent hepatic encephalopathy. An improvement of this MRI finding was not ...

1996-03-01

144

Symmetries in nuclei near the centre of the f{sub 7/2} shell  

Energy Technology Data Exchange (ETDEWEB)

High-spin states in the mirror pair nuclei {sup 49}Cr and {sup 49}Mn and their cross-conjugate partners, the mirror pair {sup 47}V and {sup 47}Cr have been investigated using experimental {gamma}-ray spectroscopic techniques. The combination of high-efficiency EUROBALL cluster Germanium detectors and clean exit-channel gating afforded by a 31-element silicon ball used in conjunction with a 15-detector neutron wall allowed a revision and extension to the energy level schemes of all four nuclei up to J{sup {pi}}=31{sup -}/2. The difference in excitation energy between states of equivalent spin in the parent nucleus and its analogue partner have thus been established for both mirror pairs up to the f{sub 7/2}-shell band terminating state for the first time. This difference is assumed to be due almost entirely to the Coulomb effect and is therefore called the Coulomb energy difference (CED). The variation in the CED with spin has been interpreted as reflecting the change in the way the ...

1998-10-01

145

Primary malignant lymphoma of the brain; Primaere maligne Lymphome des Gehirns  

Energy Technology Data Exchange (ETDEWEB)

Primary malignant lymphoma of the brain is a disease of unknown etiology, which is increasing in incidence and has an unfavorable prognosis. Despite the lack of specific changes on CT or MRI in most cases, these procedures may typically facilitate the diagnosis: A focal-enhancing mass with subependymal spread on CT or MRI and hyperattenuation on nonenhanced CT are the most reliable features in the diagnosis of primary malignant lymphoma of the brain. Peritumoral edema and mass effect are usually not prominent features. On unenhanced CT scans they usually appear homogeneously isodense to mildly hyperdense relative to the gray matter. On MRI these tumors are slightly hypointense on T1-weighted images and slightly hpyerintense on PD- and T2-weighted images relative to the gray matter. On CT and MRI enhancement is usually homogeneous. Contrast-enhanced MRI, with its multiplanar capability, lack of bone-induced artifacts, and high-contrast ...

1997-01-01

146

MRT of the abdomen in combination with enteroclysis in Crohn disease with oral and intravenous Gd-DTPA; MRT des Abdomens in Kombination mit der Enteroklyse bei Morbus Crohn unter Verwendung von oralem und intravenoesem Gd-DTPA  

Energy Technology Data Exchange (ETDEWEB)

60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A brilliant MR-tomographic imaging of the small bowel is possible under the condition, that the small bowel contrast is optimal. The ...

1998-01-01

147

MR imaging guidance and monitoring of focal thermotherapies. A review; Steuerung und Monitoring von fokalen Thermotherapien mit der Magnetresonanztomographie. Ein Ueberblick  

Energy Technology Data Exchange (ETDEWEB)

Minimally invasive thermotherapies for focal tissue destruction on the basis of laser-, microwave-, focused ultrasound-, or cryogeninduced changes of tissue temperature represent an alternative to surgical tissue ablation, particularly in the treatment of tumors. The thermotherapy modalities listed necessitate indirect guidance and monitoring, since they often do not lend themselves to immediate visual control. In the brain, in head and neck tumors, in the liver, and in the prostate, MRI reliably and accurately delineates both the positions of interstitial thermotherapy applicators and - in contrast-enhanced, T1-weighted images - the perfusion defects in tissue necrosis induced by thermotherapy. The transfer of results of in-vitro and in-vivo model studies to assess interstitial temperature and lesion development during thermotherapy to the actual treatment of patients, however, is still in an initial phase. Further development of both rapid ...

1998-03-01

148

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system  

International Nuclear Information System (INIS)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical ...

149

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas; CT und MRT des erworbenen Cholesteatoms: Prae- und postoperative Bildgebung  

Energy Technology Data Exchange (ETDEWEB)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions ...

2003-03-01

150

Staging of multiple myeloma with MRI: comparison to MSCT and conventional radiography; Staging des multiplen Myeloms mit der MRT: Vergleich zur MSCT und zur konventionellen Roentgendiagnostik  

Energy Technology Data Exchange (ETDEWEB)

The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector computed tomography ...

2004-09-01

151

Squamous cell carcinoma of the oropharynx: Ki-67 and p53 can identify patients at high risk for local recurrence after surgery and postoperative radiotherapy  

International Nuclear Information System (INIS)

Purpose: To assess the prognostic value of biologic (p53, Ki-67) and clinical factors in squamous cell carcinoma of the oropharynx after radical surgery and postoperative radiotherapy (RT). Methods and Materials: Between 1985 and 1995, a total of 102 patients with 104 tumor sites were entered onto the study. Fifty-five primary tumors (53%) involved the tonsils, 26 (25%) the soft palate, and 23 (22%) the base of the tongue. Median age was 53 years (range 36-80 years). The clinical T- and N-categories (UICC 1997) were: T1 (30), T2 (47), T3 (22), T4 (5), N0 (33), N1 (28), N2 (42), and N3 (1). Histologically-clear margins were achieved in all patients by initial surgery. Postoperative RT to the primary and regional lymphatics was given, to a total of 60 Gy in 6 weeks, and single daily fractions of 2 Gy. The expression of the nuclear p53- and Ki-67-labeling index (LI) was investigated by immunostaining using the monoclonal antibodies DO-7 and MIB 1. ...

2000-11-01

152

Diagnosis of plasmocytomas using magnetic resonance imaging; Diagnostik des Plasmozytoms mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis ...

2000-08-01

153

Use of sewage sludge and coconut coir mix as a peat substitute for potted chrysanthemum  

Energy Technology Data Exchange (ETDEWEB)

Recent central processing of domestic wastewater in Malaysia has initiated investigations into the disposal/utilization of the sewage sludge produced. We had conducted an experiment to investigate the feasibility of using dewatered sewage sludge and coconut coir as a peat substitute in a potting medium for chrysanthemum. The experiment involved 9 treatments with sewage sludge (SS) and coconut coir (CC) mixed in different ratios (v/v) to replace peat in the standard potting medium of 3:2:1 (soil: peat: sand).The potting medium contained the following treatments, T1: peat + recommended rates of Agroblend (Ag), a slow release fertilizer, and Grofas (Gf), a foliar fertilizer (commonly used medium and fertilization), T2: [1SS:1CC] + Ag, T3: [1SS:1CC] + half recommended rates of Agroblend and Grofas (1/2Ag + 1/2Gf), T4: [2SS:1CC] + Ag, T5: [2SS:1CC] + 1/2Ag + 1/2Gf, T6: [3SS:1CC] + Ag, T7: [3SS:1CC] + 1/2Ag + 1/2Gf, T8: [4SS:1CC] + Ag, and T9: ...

2003-07-01

154

Unsolved problems in the diagnosis and surgical treatment of intramedullary tumors  

Energy Technology Data Exchange (ETDEWEB)

Problems and solutions in the diagnosis and operative treatment were clarified by retrospective evaluation of cases of intramedullary tumor in which MRI and surgery had been performed. The subjects were 16 patients (21-75 years old, mean age: 45 years) whose tumor was surgically removed between 1991 and 1998. MRI was performed preoperatively, and T1-weighted images, T2-weighted images, and enhanced images were obtained. Angiography was also performed in some cases. The histological diagnosis based on the MRI findings before surgery were compared with the pathological diagnosis after the operation. In 9/16 cases (56%), the preoperative histological diagnosis based on the MR images was the same as the pathological diagnosis after the operation. In 8 of the 11 cases (73%) whose images showed clear tumor margins and well shaped the tumor, the tumors were completely removed. The concordance rate between the pathological diagnosis during and after ...

2001-04-01

155

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas  

International Nuclear Information System (INIS)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions ...

2003-03-01

156

Synthesis and radiolabelling of cysteine derivatives and pharmacological behaviour of their "9"9"mTc complexes  

International Nuclear Information System (INIS)

Full text: HMPAO, a butane monoxime derivative of propylene amine and ECD, ethyl cysteinate dimer, are currently being used as brain imaging agents. In an effort to develop new radiopharmaceuticals for imaging brain, we have synthesized amine and imine derivatives of ethyl cysteinate with butane monoxime, optimized labelling procedure with "9"9"mTc and studied the in vivo behaviour of their "9"9"mTc complexes. Imine derivative of ethyl cysteinate with butane monoxime was synthesized by refluxing equimolar amounts of butane monoxime and ethyl cystinate in dry benzene for 3 hours. The product was purified over silica with 10% ethyl acetate in chloroform as eluent. Amine derivative was prepared by reducing the imine derivative with sodium borohydride. The ligands were characterized by NMR spectroscopy and were found to be pure. The ligands were labelled with "9"9"mTc using stannous chloride as reducing agent. The complexes were characterized by paper chromatography, paper electrophoresis ...

1998-09-01

157

Studies of weak hcp "3He-"4He solution decomposition and magnetic properties of decomposed samples  

International Nuclear Information System (INIS)

The information is reported on the kinetics of decomposition of weak hcp "3He-"4He solutions with the starting "3He concentration 0.5#+-#0.1% and 1.20#+-#0.2% under the sample pressure 3.5 to 3.8 MPa before the decomposition. The NMR technique of the prompt control of the phase separation process is developed. To accelerate the metastable phase decomposition, the samples were thermally cycled at temperatures below 100 mK. Using the pulse NMR method, the magnetic susceptibility of "3He nuclei and the spin-lattice T_1 and spin-spin T_2 relaxation times were measured on three samples of the decomposed solid solutions with the starting "3He concentration 0.5% at the pressures 3.53, 3.71 and 3.78 MPa. Above 10 mK the Curie-Weiss constant was two to three times higher than the values typical of bulk bcc "3He of the corresponding density. Below 10 mK the magnetic susceptibility was observed to deviate from the Curie-Weiss law. One of the samples ...

158

Radiologic findings of extraosseous Ewing's sarcoma  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. Margins were well defined in four out of the six patients. Four patients had ...

2005-09-01

159

Pituitary gland height evaluated by MR in patients with {beta}-thalassemia major: a marker of pituitary gland function  

Energy Technology Data Exchange (ETDEWEB)

In transfusion-dependent {beta}-thalassemia major, increased iron deposition in the pituitary gland has a cytotoxic effect leading mainly to hypogonadotropic hypogonadism. Our purpose was to assess in these patients the height of the pituitary gland and to evaluate whether it represents a marker of pituitary gland function. In 29 patients with {beta}-thalassemia major and 35 age- and gender-matched controls the pituitary gland height was evaluated in a midline sagittal scan using a spin echo T1-weighted (500/20 TR/TE) sequence. In all patients, an extensive endocrine evaluation was performed, including measurements of spontaneous and stimulated levels of gonadotropins, thyroid hormones, growth hormone, insulin-like growth factor, and adrenal hormones. The pituitary gland height was lower in thalassemic patients with hypogonadotropic hypogonadism (n=15) (mean 3.48; SD 0.46) than in the age- and gender-matched controls (mean 6.29; SD 0.77), ...

2001-12-01

160

Pituitary disease in childhood: utility of magnetic resonance; Patologia hipofisaria en la edad pediatrica: unidad de la resonance magnetica  

Energy Technology Data Exchange (ETDEWEB)

To assess the utility of magnetic resonance (MR) imaging in the study of pediatric patients with clinical suspicion of pituitary disease. We studied 18 patients aged 7 to 18 years.Fifteen had hormonal disturbances, two presented amenorrhea and 1 complained of headache, fever and symptoms of polyuria and polydipsia. All the patients were examined using a Siemens SP 42 1-Tesla MRI scanner. Sagittal and coronal T1-weighted spin-echo images were obtained; in addition T2-weighted spin-echo or fast spin-echo imaging was performed in ten cases and intravenous gadolinium was administered in nine. We found 9 patients with hypothalamic-pituitary dysgenesis, 2 with germinoma, 2 cases of pituitary hemosiderosis in patients with thalassemia, 2 cases of microadenoma, one abscess, one case of idiopathic central diabetes insipidus and one of Langerhans cell histiocytosis. MR enabled us to assess pituitary structural alterations in children with ...

2000-07-01

 
 
 
 
161

New technetium-99m radiopharmaceuticals for brain imaging  

International Nuclear Information System (INIS)

Radiopharmaceuticals for brain imaging are used for the detection of ischemia, tumours and dementia associatied with disorders of the blood flow in the brain. The current radiopharmaceuticals for brain imaging have various limitations: 2-(F-18)fluoro-2-deoxyglucose (F-18-FDG) has a very short half-life. The physical properties of di-#beta#-(piperidinoethyl)-(Se-75)selenide (Se-75-PIPSE) and di-#beta#-(morpholinoethyl)-(Se-75)-selenide (Se-75-MOSE) are not ideal. Thallium-201 diethyldithricarbamate (T1-201-DDC) has unfavourable nuclidic characteristics, limited availability, a long half-life and high cost. I-123 in N-isopropyl-p-iodoamphetamine (I-123-IMP) and N,N,N'-trimethyl-N'-(2-hydroxy-3-methyl-5-iodobenzyl)-1,3-propanediamine (I-123-HIPDM) are not freely available and are expensive. N-13-labelled ammonia has a very short half-life. Technetium-99m hexamethylpropyleneamineoxime (Tc-99m-HM-PAO) is unstable both in vitro and in vivo and has a ...

1988-08-01

162

Monitoring the effect of chemotherapy in Ewing's sarcoma of bone with MR imaging  

International Nuclear Information System (INIS)

Magnetic resonance (MR) imaging was performed in 26 patients with Ewing's sarcoma of bone preceding and following neoadjuvant chemotherapy, to assess tumour response non-invasively prior to surgery. T1- and T2-weighted spin echo images were obtained. Changes including intra- and extramedullary signal intensities, tumour demarcation, tumour volume and the appearance of residual extramedullary tumour were compared with histophathology of the resected specimens. Reduction of tumour volume was significantly higher in good responders. Other single parameters did not correlated with histologic tumour response. However, when several MR parameters summarized in a classification system were combined, a positive correlation with histopathologic response was found. A limited decrease of tumour volume (<25 %) and/or residual soft tissue mass following chemotherapy correlated with a poor response. An inhomogeneous, well-defined cuff of abnormal tissue ...

163

Magnetic resonance imaging assessment of brain maturation in preterm neonates with punctate white matter lesions  

International Nuclear Information System (INIS)

Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weighted images and decreased signal on T2-weighted images with no evidence of cystic degeneration. A group of 22 preterm infants with PWML at term PMA (PWML group) were compared with 22 matched controls with a normal MR appearance. The two groups ...

2007-02-01

164

MRI in the diagnosis of non-compacted ventricular Myocardium (NCVM) compared to echocardiography  

International Nuclear Information System (INIS)

Purpose: To report the detection of con-compacted ventricular myocardium (NVCM) with MRI compared to echocardiography in 8 patients. Material and methods: Non-compaction of the ventricular myocardium is a congenital disorder characterized by an altered structure of the myocardial wall resulting from an intrauterine arrest in endomyocardial embryogenesis. The morphological findings consist of a prominent meshwork of multiple myocardial trabeculations and deep intertrabecular recesses, communicating with the left ventricular cavity. 8 consecutive patients (mean age 7.3 years) with clinical and echocardiographic signs of NCVM were examined by MRI (1.5 T, Vision, Siemens) in short axis and 2- and 4-chamber views, using T_1-weighted TSE and Cine-GRE in 6 patients and true FISP sequences in 2 patients. MRI and echocardiography were evaluated for visibility, signs of NCVM and involvement of myocardial wall segments. Thickness was measured for ...

2003-09-01

165

MR findings in cases of suspected impacted fracture of the femoral neck  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced intertrochanteric ...

1997-09-01

166

MR evaluation of rectal carcinoma: pelvic phased-array coil versus endorectal-pelvic phased-array coil  

Energy Technology Data Exchange (ETDEWEB)

To compare the accuracy of MR imaging using an endorectal-pelvic and a pelvic phased-array coil for preoperative local staging of rectal carcinoma. To determine preoperative staging, 38 patients with rectal carcinoma underwent MR imaging. All patients were examined with both an endorectal-pelvic and a pelvic phased-array coil. All underwent surgery and staging was pathologically confirmed. Two radiologists blinded to pathologic stage analyzed perirectal invasion and perirectal node metastasis, and scored according to a four-point scale. Radiologic and pathologic findings were correlated. Receiver operating characteristic (ROC) analysis of Wilcoxon statistic (W values) was used to compare diagnostic accuracy between the two different MR methods. Interobserver variation was measured using {kappa} statistics. For perirectal invasion, T1WI endorectal-pelvic phased-array coil images (reader 1:0. 854, reader 2:0.818) showed higher W values than ...

1998-10-01

167

Influence of plasma nitriding on fatigue strength and fracture of a B-Mn steel  

Energy Technology Data Exchange (ETDEWEB)

The first part of a systematic investigation is presented of surface treatments affecting the fatigue behavior of smooth and notched quenched and tempered (Q and T) specimens made of a B-Mn SS2131 ({approx}AISI 15B21H) steel. In this part, the effects of plasma nitriding (nitriding temperature=480 C, time=24 h) on the fatigue strength and notch sensitivity were investigated. Constant stress amplitude plane reversed bending fatigue tests (R=-1) at 47 Hz were conducted using cylindrical plasma nitriding (PN) and Q and T steel specimens with K{sub t}=1.05 and 1.7. The compound layer was found to consists of {epsilon}-phase and {gamma}`-phase. S-N curves show that plasma nitriding improves the fatigue limit by 53 and 115% of Q and T smooth and notched specimens, respectively. The fatigue strength of smooth specimens is improved through the whole fatigue life but only for long fatigue lives for notched specimens. Plasma nitriding reverses the low ...

1998-02-01

168

Implant detectibility of intervertebral disc spacers in post fusion MRI: evaluation of the MRI scan quality by using a scoring system - an in vitro study  

International Nuclear Information System (INIS)

Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium and cobalt chromium alloys and carbon fiber-reinforced polymers. Implant-related susceptibility artifacts can decrease the quality of MRI scans. The aim of this cadaveric study was to demonstrate the extent that implant-related MRI artifacting affects the postfusion differentiation of determined regions of interest (ROIs). In six cadaveric porcine spines, we evaluated the postimplantation MRI scans of a titanium, cobalt-chromium and carbon spacer that differed in shape and surface qualities. A spacer made of human cortical bone was used as a control. A defined evaluation unit was divided into ROIs to characterize the spinal canal as well as the intervertebral disc space. Considering 15 different MRI sequences read independently by an interobserver-validated team of specialists the artifact-affected image quality of the median MRI slice was rated on a score of 0-3. A maximum score of 18 ...

2007-02-01

169

High-affinity lead binding proteins in rat kidney cytosol mediate cell-free nuclear translocation of lead  

Energy Technology Data Exchange (ETDEWEB)

The PbII binding characteristics of the previously reported PbII binding proteins of rat kidney cytosol were investigated further. Saturation and Scatchard analysis of /sup 203/Pb binding in whole cytosol and in 40% saturated ammonium sulfate precipitated fractions disclosed a class of relatively high-affinity sites with an apparent Kd of approximately 50 nM and binding capacities of approximately 41 and 9 pmol/mg of protein, respectively. Two /sup 203/Pb binding proteins with approximate molecular masses of 63K and 11.5K daltons and a high molecular weight component (greater than 200K) were isolated by Sepharose-6B column chromatography. The time course of association of /sup 203/Pb with cytosol and the 63K protein showed maximum binding at 18 hr which was stable up to 25 hr at 4 degrees C. The approximate half-time dissociation rate (T 1/2) of specifically bound /sup 203/Pb to the 63K protein was 100 min at 4 degrees C whereas the 11.5K ...

1985-02-01

170

High-affinity lead binding proteins in rat kidney cytosol mediate cell-free nuclear translocation of lead  

International Nuclear Information System (INIS)

The PbII binding characteristics of the previously reported PbII binding proteins of rat kidney cytosol were investigated further. Saturation and Scatchard analysis of "2"0"3Pb binding in whole cytosol and in 40% saturated ammonium sulfate precipitated fractions disclosed a class of relatively high-affinity sites with an apparent Kd of approximately 50 nM and binding capacities of approximately 41 and 9 pmol/mg of protein, respectively. Two "2"0"3Pb binding proteins with approximate molecular masses of 63K and 11.5K daltons and a high molecular weight component (greater than 200K) were isolated by Sepharose-6B column chromatography. The time course of association of "2"0"3Pb with cytosol and the 63K protein showed maximum binding at 18 hr which was stable up to 25 hr at 4 degrees C. The approximate half-time dissociation rate (T 1/2) of specifically bound "2"0"3Pb to the 63K protein was 100 min at 4 degrees C whereas the 11.5K protein showed ...

171

Heat transfer and fluid dynamics of high heat flux fuel rod for VHTR  

International Nuclear Information System (INIS)

Experimental studies on the heat transfer and fluid dynamics of a high heat flux fuel rod for a very high temperature reactor (VHTR) were performed using a single channel test rig of a fuel stack test section (T_1_-_s) installed in a helium engineering demonstration loop (HENDEL). The fuel rod has been developed in order to enhance the turbulent heat transfer coefficient than that of the standard fuel rod obtained by the previous experiment. Two-dimensional square ribs were settled on the outer surface of the fuel rod axially to improve the heat transfer. The configuration of a square rib is 0.5 mm in width(w), 0.5 mm in height(h) and 5 mm in pitch(p): p/h=10. The experiment were carried out under the helium gas conditions of high temperature and pressure simulated the VHTR operation. For the turbulent region of Reynolds number 2,500#approx#8,000 of the VHTR core flow condition, it was found that the heat transfer coefficient of the fuel rod ...

1991-01-01

172

Galactic evolution of D and "3He including stellar production of "3He  

International Nuclear Information System (INIS)

New stellar models which track the production and destruction of "3He (and D) have been evolved for a range of stellar masses (0.65#<=#M/M_c_i_r_c_l_e_-_d_o_t#<=#100), metallicities (0.01#<=#Z/Z_c_i_r_c_l_e_-_d_o_t#<=#1), and initial (main-sequence) "3He mass fractions (10"-"5#<=#X_3_,_M_S#<=#10"-"3). Armed with the "3He yields from these stellar models we have followed the evolution of D and "3He using a variety of chemical evolution models with and without infall of primordial or processed material. Production of new "3He by the lower mass stars overwhelms any reasonable primordial contributions and leads to predicted abundances in the presolar nebula and/or the present interstellar medium in excess of the observationally inferred values. This result, which obtains even for zero primordial D and "3He, and was anticipated by Rood, Steigman, ampersand Tinsley is insensitive to the choice of chemical evolution model; it is ...

173

Experimental investigation of the KLL Auger spectrum of "8"8Sr from the EC-decay of "8"8Y  

International Nuclear Information System (INIS)

According to the calculations, intensity of the KL_1L_2("3P_0) Auger transition should drastically increase with increasing atomic number Z due to the relativistic effects. However, this behavior was experimentally proved only for very few elements. A lack of enough precise experimental data in the atomic number region Z<45 does not enable one to distinguish between relativistic and non-relativistic approaches in this region. Thus for Z=38 the KL_1L_2("3P_0/"1P_1) intensity ratio was determined with relative uncertainty of 63 % in the only measurement with external excitation. Here we present results of our investigation of the KLL Auger electron spectrum of "8"8Sr generated in the EC decay of "8"8Y (T_1_/_2= 106.6 d). Electron spectra were measured with the 11 eV instrumental resolution using a combined electrostatic spectrometer. The present value of the KL_2L_3("1D_2) absolute transition energy in Sr is higher by 7.4 eV (i.e. more than ...

2007-06-04

174

Electron beam intraoral cone therapy in carcinoma of tongue. Report of eight cases and review of the literature  

Energy Technology Data Exchange (ETDEWEB)

The clinical results of electron beam therapy using intraoral cone in 8 cases of primary and recurrence carcinoma of tongue (T1 and smaller T2) were reported. The primary and recurrence cases were 5 and 3, respectively. In the 5 cases, a total dose of 10-30 Gy external radiation therapy were combined prior to electron beam therapy. The total dose of electron beam therapy varied from 40 to 60 Gy. In all cases, tumor showed good response and disappeared clinically. Radiation stomatitis, pain of the tongue with masticatory disturbance due to tenderness were complicated in all cases. These complications gradually disappeared 2 to 6 months after treatment. However, loss of body weight and bone exposure were not recognized in any case. Intraoral-cone electron beam therapy is thought to be available and has less complications comparing interstitial irradiation therapy from the review of literature. Within 6 months after radiation, submandibular ...

1989-06-01

175

Distributions of "1"3"7Cs, "2"0"1T1, "2"0"3Hg, "2"0"3Pb and "5"7Co in a rat hepatoma model. Comparison with "6"7Ga  

International Nuclear Information System (INIS)

The distribution of carrier-free "2"0"3Pb-acetate, "2"0"3HgCl_2, "5"7Cocl_2, "1"3"7CsCl and "2"0"1TlCl was investigated in rats bearing thigh-implanted Morris 7777 hepatomas. Viable and nonviable tumor tissue was collected in order to determine the relative affinities of the radiopharmaceutical for these tissues. The animals were sacrificed at 4, 24, 48, 72 and 96 hrs following intravenous injection. Washout of the radioisotope from the viable tumor tissue was rapid, the maximum concentration being reached on or before 4 hrs following injection. In contrast, residual activity within the nonviable tumor tissue decreased much more slowly and in some cases even increased with time. Viable tumor-to-muscle and nonvialbe tumor-to-muscle ratios for "2"0"3Pb, "2"0"3Hg and "5"7Co were comparable to the analogous ratios reported for "6"7Ga. However, none of these isotopes approached "6"7Ga as a potential tumor imaging agent because the large ratios were the result of low muscle uptake rather ...

176

Distinguishing benign notochordal cell tumors from vertebral chordoma  

Energy Technology Data Exchange (ETDEWEB)

The objective was to characterize imaging findings of benign notochordal cell tumors (BNCTs). Clinical and imaging data for 9 benign notochordal cell tumors in 7 patients were reviewed retrospectively. Conventional radiographs (n = 9), bone scintigrams (n = 2), computed tomographic images (n = 7), and magnetic resonance images (n = 8) were reviewed. Eight of the 9 lesions were stained with hematoxylin-eosin and microscopically examined. There were 3 male and 4 female patients with an age range of 22 to 55 years (average age, 44 years). Two patients had two lesions at different sites. The lesions involved the cervical spine in 4 patients, the lumbar spine in 2, the sacrum in 2, and the coccyx in 1. The most common symptom was mild pain. The lesions of 2 patients were found incidentally during imaging studies for unrelated conditions. Five patients underwent surgical procedures. One patient died of surgical complications. All other patients have been well without recurrent or progressive ...

2008-04-15

177

Direct photoaffinity labeling of gizzard myosin with ["3H]uridine diphosphate places Glu185 of the heavy chain at the active site  

International Nuclear Information System (INIS)

The active site of chicken gizzard myosin was labeled by direct photoaffinity labeling with ["3H]UDP. ["3H] UDP was stably trapped at the active site by addition of vanadate (Vi) and Co"2"+. The extraordinary stability of the myosin.Co2+.[3H]UDP.Vi complex (t1/2 greater than 5 days at 0 degrees C) allowed it to be purified free of extraneous ["3H]UDP before irradiation began. Upon UV irradiation, greater than 60% of the trapped ["3H]UDP was photoincorporated into the active site. Only the 200-kDa heavy chain was labeled, confirming earlier results using ["3H]UTP. Extensive tryptic digestion of photolabeled myosin subfragment 1 followed by high performance liquid chromatography separations and removal of nucleotide phosphates by treatment with alkaline phosphatase allowed two labeled peptides to be isolated. Sequencing of the labeled peptides and radioactive counting showed that Glu185 was the residue labeled. Since UDP is a zero-length ...

178

Diagnosis of plasmocytomas using magnetic resonance imaging  

International Nuclear Information System (INIS)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is ...

2000-08-01

179

Developmental cortical thinning in fetal alcohol spectrum disorders.  

Science.gov (United States)

Regional cortical thickness was evaluated using CIVET processing of 3D T1-weighted images (i) to compare the variation in cortical thickness between 33 participants with fetal alcohol spectrum disorders (FASD) aged 6-30 years (mean age 12.3 years) versus 33 age/sex/hand-matched controls, and (ii) to examine developmental changes in cortical thickness with age from children to young adults in both groups. Significant cortical thinning was found in the participants with FASD in large areas of the bilateral middle frontal lobe, pre- and post- central areas, lateral and inferior temporal and occipital lobes compared to controls. No significant cortical thickness increases were observed for the FASD group. Cortical thinning with age in a linear model was observed in both groups, but the locations were different for each group. FASD participants showed thinning with age in the left middle frontal, bilateral precentral, bilateral precuneus and ...

2011-06-17

180

Dendroaspis natriuretic peptide and the designer natriuretic peptide, CD-NP, are resistant to proteolytic inactivation.  

Science.gov (United States)

Designer natriuretic peptides (NPs) represent an active area of drug development. In canine and human studies, the designer natriuretic peptide CD-NP demonstrated more desirable therapeutic potential than recombinant B-type NP (BNP), which is known as nesiritide and is approved for treatment of acute decompensated heart failure. However, why CD-NP is more effective than BNP is not known. We previously reported that CD-NP is a poorer activator of human guanylyl cyclase-A (GC-A) and a better activator of human guanylyl cyclase-B than BNP. Here, guanylyl cyclase bioassays were used to compare the susceptibility of CD-NP verses ANP, BNP, CNP and DNP to inactivation by human kidney membranes. The half time (t(1/2)) for CD-NP inactivation was increased by factors of 13, 3 and 4 compared to ANP, BNP and CNP, respectively, when measured in the same assay. Surprisingly, DNP failed to undergo complete inactivation and was the most degradation resistant ...

2011-04-01

 
 
 
 
181

Cranial MRI of neurologically impaired children suffering from neonatal hypoglycaemia  

International Nuclear Information System (INIS)

Background. Metabolic disturbances such as anoxia and hypoglycaemia are important in causing maldevelopment of the neonatal brain. While there have been some pathology studies of the effects of neonatal hypoglycaemia on brain development, reports of MRI findings in such infants have been rare. Objectives. To describe the MRI findings in neurologically handicapped children who had suffered from neonatal hypoglycaemia and to evaluate the relationship between the neurological impairment and neonatal hypoglycaemia. Materials and methods. We retrospectively evaluated the MRI findings in eight full-term infants with neonatal symptomatic hypoglycaemia who later exhibited neurological handicap. The age at which the MRI scans were obtained ranged from 9 months to 8 years 10 months (mean 4 years 1 month, median 4 years). Results. The most striking findings were prolonged T1 weighting and T2 weighting in the parieto-occipital periventricular deep white ...

1999-01-01

182

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system; Hochaufloesendes Ganzkoerpertumorstaging unter Verwendung paralleler Bildgebung im Vergleich zur PET-CT. Erste Erfahrungen auf einem 32-Kanal-MRT-System  

Energy Technology Data Exchange (ETDEWEB)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical ...

2004-09-01

183

Bone marrow MR imaging as predictors of outcome in hemopoietic stem cell transplantation  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate the role of femoral marrow MR imaging as predictor of outcome for hemopoietic stem cell transplantation (HSCT) in beta-thalassemia major. MR imaging of the proximal femur, including T1- and T2-weighted spin echo and short-tau inversion recovery and in-phase and out-of-phase fast field echo images, was prospectively performed in 27 thalassemia major patients being prepared for HSCT. The area of red marrow and its percentage of the proximal femur were measured, and the presence of marrow hemosiderosis was assessed. Age-adjusted multivariate logistic regression was used to determine the relationship between red marrow area percentage and marrow hemosiderosis and HSCT outcome. Red area percentage were less in patients with successful (90.25{+-}4.14%) compared to unsuccessful transplants (94.54% {+-}2.93%; p=0.01). Red marrow area percentage correlated positively with duration of symptoms(r=0.428, p=0.026) ...

2008-09-15

184

Are the delay images necessary to evaIuate the liver metastatic lesions on mangafodipir trisodium enhanced liver MRI?: comparison with hepatocellular carcinomas  

Energy Technology Data Exchange (ETDEWEB)

To assess whether ring enhancements of liver metastases on Mn-DPDP enhanced, early MR images were well visualized on delayed images, as compared with those of hepatocellular carcinomas (HCC), and to investigate the detection accuracy and conspicuity of each tumor. Twenty patients with liver metastases and 15 with HCC were studied by Mn-DPDP enhanced, T1-weighted MR images. Peripheral ring enhancement and conspicuity were investigated. Differences in detection accuracy and frequency of ring enhancement in liver metastases and HCC were assessed. In liver metastases (n= 69), 44 cases (63.8%) without ring enhancement and 25 (36.2%) with were noted on early images. Sixteen cases (23.2%) without ring enhancement, 38 (55.1%) with ring enhancement similar to the early images, and 15 (21.7%) with prominent ring enhancement were noted on delayed images. In HCC (n=37), 36 cases (97.3%) without ring enhancement and 1 case (2.7%) with were noted on early ...

2004-09-01

185

A study of palladium silicide formed by focused ion beam implantation of palladium ions  

International Nuclear Information System (INIS)

The formation and properties of Pd_2Si formed by focused ion beam implantation of Pd ions into Si is presented in this thesis. An extensive microstructural study using transmission electron microscopy was undertaken and the as-implanted as well as annealed microstructure is shown. Results of other analysis techniques such as Rutherford back scattering and secondary ion mass spectrometry etc. are also presented. Kinetic information on the growth of Pd_2Si obtained by both microstructural and resistance measurements indicates that the activation energy for growth of the silicide is around 0.36 to 0.39 eV. This can be compared with the normally reported value of 1.5 eV for Pd_2Si formed by annealing thin film Pd on Si. The growth of the silicide was found to follow t"1"/"2 kinetics. Microstructural observation of the as-implanted samples showed extensive in-situ formation of Pd_2Di and also surprisingly few defect structures. A heat transfer model ...

186

A Wheat Homolog of MOTHER OF FT AND TFL1 Acts in the Regulation of Germination.  

Science.gov (United States)

Seed dormancy is an adaptive mechanism and an important agronomic trait. Temperature during seed development strongly affects seed dormancy in wheat (Triticum aestivum) with lower temperatures producing higher levels of seed dormancy. To identify genes important for seed dormancy, we used a wheat microarray to analyze gene expression in embryos from mature seeds grown at lower and higher temperatures. We found that a wheat homolog of MOTHER OF FT AND TFL1 (MFT) was upregulated after physiological maturity in dormant seeds grown at the lower temperature. In situ hybridization analysis indicated that MFT was exclusively expressed in the scutellum and coleorhiza. Mapping analysis showed that MFT on chromosome 3A (MFT-3A) colocalized with the seed dormancy quantitative trait locus (QTL) QPhs.ocs-3A.1. MFT-3A expression levels in a dormant cultivar used for the detection of the QTL were higher after physiological maturity; this increased expression correlated with a single nucleotide ...

2011-09-01

187

The Prognostic Significance of p53, Bcl-2, Cytokeratin 20 and Ki-67 in Primary Superficial Papillary Transitional Bladder Carcinoma  

International Nuclear Information System (INIS)

Identification of factors that determine individual patient risk for recurrence and progression in superficial papillary carcinoma of the bladder is a subject of extensive research as it would be a major outcome in patient management. It has been well recognized that traditional prognostic markers as tumor grade and stage are not accurate enough in predicting biological behavior. A large number of markers have been investigated as potential prognostic factors and relatively few can help in predicting outcome. Material and Methods: Forty-nine cases undergoing complete transurethral resection for primary superficial papillary transitional cell carcinoma were subjected to clinicopathologic evaluation as well as immunohistochemical staining for p53, bcl-2, cytokeratin 20 and Ki-67. The CAS-200 image analyzer was used to estimate the Ki-67 labeling index. Results: Recurrence was observed in 19 cases (38.8%) and progression in 7 cases (14.3%) with a median followup of 49 months (range 24-84 ...

2003-03-01

188

Preparatory Signal Detection for Annex I Countries under the Kyoto Protocol. A Lesson for the Post-Kyoto Policy Process  

Energy Technology Data Exchange (ETDEWEB)

The focus of this study is on the preparatory detection of uncertain net greenhouse gas (GHG) emission changes (also termed emission signals) under the Kyoto Protocol. The crucial question to be addressed is: How well do we need to know net emissions if we want to detect a specified emission signal after a given time? No restrictions exist as to what concerns the net emitter, which may be any GHG source or sink. Annex I countries are chosen as net emitters, simply for reasons of data availability and because of the excellent possibility of comparing net emitters (inter-country comparison). The countries' emissions - in an increasing number of cases even their uncertainties - are available permitting the application of preparatory signal detection techniques, which are suited to address the aforementioned question. We currently discuss four hierarchically-ordered detection concepts to assess emission signals in a preparatory manner, that is, at two predefined points in time, ...

2004-06-14

189

Multi-modality imaging of uveal melanomas using combined PET/CT, high-resolution PET and MR imaging  

Energy Technology Data Exchange (ETDEWEB)

We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded for confidence: 1: none, 2: suggestive, 3: clear. Mean tumour activity was calculated for summed image frames that resulted ...

2008-07-01

190

In vitro MRI of brain development  

International Nuclear Information System (INIS)

In this review, we demonstrate the developmental appearance, structural features, and reorganization of transient cerebral zones and structures in the human fetal brain using a correlative histological and MRI analysis. The analysis of postmortem aldehyde-fixed specimens (age range: 10 postovulatory weeks to term) revealed that, at 10 postovulatory weeks, the cerebral wall already has a trilaminar appearance and consists of: (1) a ventricular zone of high cell-packing density; (2) an intermediate zone; (3) the cortical plate (in a stage of primary consolidation) with high MRI signal intensity. The anlage of the hippocampus is present as a prominent bulging in the thin limbic telencephalon. The early fetal telencephalon impar also contains the first commissural fibers and fornix bundles in the septal area. The ganglionic eminence is clearly visible as an expanded continuation of the proliferative ventricular zone. The basal ganglia showed an initial aggregation of cells. The most ...

2006-02-01

191

Hungarian situation of the technologically enhanced naturally occuring radioactive materials  

International Nuclear Information System (INIS)

Full text: In Hungary, the main goal is that the Hungarian regulations should meet with the EU Directive No. 96/29. For this aim, a surveying project has been launched in order to collect all relevant information about the Hungarian TENORM situation. This surveying programme covers a lot of data collection (work activities, disposal places, residue quantities) and radiological measurements on the TENORM site. The Hungarian situation of TENORM definitely differs from other countries in the aspect of occurrence forms of natural sources (or in the imported raw materials), in the quantities of exploitation, in the level of the radioactivity and in the applied technological processes. Firstly, those work activities have been choosen where the huge amount of residues have been produced. The other criteria is that the activity concentration in a great portion of the given residues is much higher than the average activity concentration of the typical Hungarian soil. After filtering and ...

2003-08-17

192

Non cardiopatic and cardiopatic beta thalassaemic patients: quantitative and qualitative cardiac iron deposition evaluation with MRI; Pazienti {beta} talassemici non cardiopatici e cardiopatici: valutazione quantitativa e qualitativa del deposito di ferro cardiaco con RM  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Cardiomyopathy is one of the major complications of {beta} thalassaemia major as a result of transfusion iron overload. The aim of our study is to evaluate with MR if there is any difference of iron deposition signal intensity (SI) or distribution between non-cardiopatic and cardiopatic thalassaemic patients in order to establish if there is a relationship between cardiopathy and iron deposition. Materials and methods: We studied 20 patients affected by {beta} thalassaemia major, of whom 10 cardiopatic and 10 non-cardiopatic, and 10 healthy volunteers as control group. Serum ferritin and left ventricular ejection fraction were calculated in thalassaemic patients. All patients were examinated using a 1.5 MR unit with ECG-gated GE cine-MR T2*-weighted, SE T1-weighted and GE T2*-weighted sequences. In all cases, using an adequate ROI, the myocardial and skeletal muscle signal intensity (SI), the myocardial/skeletal muscle signal intensity ...

2005-02-01