WorldWideScience

Sample records for sapphire hematology analyzer

  1. Comparison of five automated hematology analyzers in a university hospital setting: Abbott Cell-Dyn Sapphire, Beckman Coulter DxH 800, Siemens Advia 2120i, Sysmex XE-5000, and Sysmex XN-2000.

    Science.gov (United States)

    Bruegel, Mathias; Nagel, Dorothea; Funk, Manuela; Fuhrmann, Petra; Zander, Johannes; Teupser, Daniel

    2015-06-01

    Various types of automated hematology analyzers are used in clinical laboratories. Here, we performed a side-by-side comparison of five current top of the range routine hematology analyzers in the setting of a university hospital central laboratory. Complete blood counts (CBC), differentials, reticulocyte and nucleated red blood cell (NRBC) counts of 349 patient samples, randomly taken out of routine diagnostics, were analyzed with Cell-Dyn Sapphire (Abbott), DxH 800 (Beckman Coulter), Advia 2120i (Siemens), XE-5000 and XN-2000 (Sysmex). Inter-instrument comparison of CBCs including reticulocyte and NRBC counts and investigation of flagging quality in relation to microscopy were performed with the complete set of samples. Inter-instrument comparison of five-part differential was performed using samples without atypical cells in blood smear (n=292). Automated five-part differentials and NRBCs were additionally compared with microscopy. The five analyzers showed a good concordance for basic blood count parameters. Correlations between instruments were less well for reticulocyte counts, NRBCs, and differentials. The poorest concordance for NRBCs with microscopy was observed for Advia 2120i (Kendall's τb=0.37). The highest flagging sensitivity for blasts was observed for XN-2000 (97% compared to 65%-76% for other analyzers), whereas overall specificity was comparable between different instruments. To the best of our knowledge, this is the most comprehensive side-by-side comparison of five current top of the range routine hematology analyzers. Variable analyzer quality and parameter specific limitations must be considered in defining laboratory algorithms in clinical practice.

  2. Verification and quality control of routine hematology analyzers.

    Science.gov (United States)

    Vis, J Y; Huisman, A

    2016-05-01

    Verification of hematology analyzers (automated blood cell counters) is mandatory before new hematology analyzers may be used in routine clinical care. The verification process consists of several items which comprise among others: precision, accuracy, comparability, carryover, background and linearity throughout the expected range of results. Yet, which standard should be met or which verification limit be used is at the discretion of the laboratory specialist. This paper offers practical guidance on verification and quality control of automated hematology analyzers and provides an expert opinion on the performance standard that should be met by the contemporary generation of hematology analyzers. Therefore (i) the state-of-the-art performance of hematology analyzers for complete blood count parameters is summarized, (ii) considerations, challenges, and pitfalls concerning the development of a verification plan are discussed, (iii) guidance is given regarding the establishment of reference intervals, and (iv) different methods on quality control of hematology analyzers are reviewed. © 2016 John Wiley & Sons Ltd.

  3. Verification and quality control of routine hematology analyzers

    NARCIS (Netherlands)

    Vis, J Y; Huisman, A

    2016-01-01

    Verification of hematology analyzers (automated blood cell counters) is mandatory before new hematology analyzers may be used in routine clinical care. The verification process consists of several items which comprise among others: precision, accuracy, comparability, carryover, background and

  4. Interpretation of erythrocyte histograms obtained from automated hematology analyzers in hematologic diseases

    Directory of Open Access Journals (Sweden)

    Ali Maleki

    2015-12-01

    Full Text Available Background: Presently, the graphical data of blood cells (histograms and cytograms or/ scattergrams that they are usually available in all modern automated hematology analyzers are an integral a part of automated complete blood count (CBC. To find incorrect results from automated hematology analyzer and establish the samples that require additional analysis, Laboratory employees will use those data for quality control of obtaining results, to assist identification of complex and troublesome cases. Methods: During this descriptive analytic study, in addition to erythrocyte graphs from variety of patients, referring from March 2013 to Feb 2014 to our clinical laboratory, Zagros Hospital, Kermanshah, Iran, are given, the papers published in relevant literature as well as available published manuals of automatic blood cell counters were used. articles related to the key words of erythrocyte graphs and relevant literature as well as available published manuals of automatic blood cell counters were searched from valid databases such as Springer Link, google scholar, Pubmed and Sciencedirect. Then, the articles related to erythrogram, erythrocyte histogram and hematology analyzer graphs are involved in diagnosis of hematological disorder were searched and selected for this study. Results: Histograms and different automated CBC parameter become abnormal in various pathologic conditions, and can present important clues for diagnosis and treatment of hematologic and non-hematologic disorders. In several instances, these histograms have characteristic appearances in an exceedingly wide range of pathological conditions. In some hematologic disorders like iron deficiency or megaloblastic anemia, a sequential histogram can clearly show the progressive treatment and management. Conclusion: These graphical data are often accompanied by other automated CBC parameter and microscopic examination of peripheral blood smears (PBS, and can help in monitoring and

  5. Automated quantification of apoptosis in B-cell chronic lymphoproliferative disorders: a prognostic variable obtained with the Cell-Dyn Sapphire (Abbott) automated hematology analyzer.

    Science.gov (United States)

    Fumi, M; Martins, D; Pancione, Y; Sale, S; Rocco, V

    2014-12-01

    B-chronic lymphocytic leukemia CLL, a neoplastic clonal disorder with monomorphous small B lymphocytes with scanty cytoplasm and clumped chromatin, can be morphologically differentiated in typical and atypical forms with different prognosis: Smudge cells (Gumprecht's shadows) are one of the well-known features of the typical CLL and are much less inconsistent in other different types CLPD. Abbott Cell-Dyn Sapphire uses the fluorescence after staining with the DNA fluorochrome propidium iodide for the measurement of nucleated red blood cells (NRBCs) and nonviable cells (FL3+ cell fraction): We have studied the possible correlation between presence and number of morphologically identifiable smudge cells on smears and the percentage of nonviable cells produced by Cell-Dyn Sapphire. 305 blood samples from 224 patients with B-cell lymphoproliferative disorders and 40 healthy blood donors were analyzed by CBC performed by Cell-Dyn Sapphire, peripheral blood smear, and immunophenotype characterization. FL3+ fraction in CLPD directly correlated with the percentage of smudge cells and is significantly increased in patients with typical B-CLL. This phenomenon is much less evident in patients with atypical/mixed B-CLL and B-NHL. In small laboratories without FCM and cytogenetic, smudge cells%, can be utilized as a preliminary diagnostic and prognostic tool in differential diagnosis of CLPD. © 2014 John Wiley & Sons Ltd.

  6. Evaluation of performance of veterinary in-clinic hematology analyzers.

    Science.gov (United States)

    Rishniw, Mark; Pion, Paul D

    2016-12-01

    A previous study provided information regarding the quality of in-clinic veterinary biochemistry testing. However, no similar studies for in-clinic veterinary hematology testing have been conducted. The objective of this study was to assess the quality of hematology testing in veterinary in-clinic laboratories using results obtained from testing 3 levels of canine EDTA blood samples. Clinicians prepared blood samples to achieve measurand concentrations within, below, and above their RIs and evaluated the samples in triplicate using their in-clinic analyzers. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index, and agreement between in-clinic and reference laboratory instruments. Suitability for statistical quality control was determined using adaptations from the computerized program, EZRules3. Evaluation of 10 veterinary in-clinic hematology analyzers showed that these instruments often fail to meet quality requirements. At least 60% of analyzers reasonably determined RBC, WBC, HCT, and HGB, when assessed by most quality goal criteria; platelets were less reliably measured, with 80% deemed suitable for low platelet counts, but only 30% for high platelet counts, and automated differential leukocyte counts were generally considered unsuitable for clinical use with fewer than 40% of analyzers meeting the least stringent quality goal requirements. Fewer than 50% of analyzers were able to meet requirements for statistical quality control for any measurand. These findings reflect the current status of in-clinic hematology analyzer performance and provide a basis for future evaluations of the quality of veterinary laboratory testing. © 2016 American Society for Veterinary Clinical Pathology.

  7. Performance evaluation of the Abbott CELL-DYN Emerald for use as a bench-top analyzer in a research setting.

    Science.gov (United States)

    Khoo, T-L; Xiros, N; Guan, F; Orellana, D; Holst, J; Joshua, D E; Rasko, J E J

    2013-08-01

    The CELL-DYN Emerald is a compact bench-top hematology analyzer that can be used for a three-part white cell differential analysis. To determine its utility for analysis of human and mouse samples, we evaluated this machine against the larger CELL-DYN Sapphire and Sysmex XT2000iV hematology analyzers. 120 human (normal and abnormal) and 30 mouse (normal and abnormal) samples were analyzed on both the CELL-DYN Emerald and CELL-DYN Sapphire or Sysmex XT2000iV analyzers. For mouse samples, the CELL-DYN Emerald analyzer required manual recalibration based on the histogram populations. Analysis of the CELL-DYN Emerald showed excellent precision, within accepted ranges (white cell count CV% = 2.09%; hemoglobin CV% = 1.68%; platelets CV% = 4.13%). Linearity was excellent (R² ≥ 0.99), carryover was minimal (laboratories or as a backup system in larger laboratories. © 2012 John Wiley & Sons Ltd.

  8. Quality requirements for veterinary hematology analyzers in small animals-a survey about veterinary experts' requirements and objective evaluation of analyzer performance based on a meta-analysis of method validation studies: bench top hematology analyzer.

    Science.gov (United States)

    Cook, Andrea M; Moritz, Andreas; Freeman, Kathleen P; Bauer, Natali

    2016-09-01

    Scarce information exists about quality requirements and objective evaluation of performance of large veterinary bench top hematology analyzers. The study was aimed at comparing the observed total error (TEobs ) derived from meta-analysis of published method validation data to the total allowable error (TEa ) for veterinary hematology variables in small animals based on experts' opinions. Ideally, TEobs should be hematology analyzers (ADVIA 2120; Sysmex XT2000iV, and CellDyn 3500) was calculated based on method validation studies published between 2005 and 2013 (n = 4). The percent TEobs = 2 * CV (%) + bias (%). The CV was derived from published studies except for the ADVIA 2120 (internal data), and bias was estimated from the regression equation. A total of 41 veterinary experts (19 diplomates, 8 residents, 10 postgraduate students, 4 anonymous specialists) responded. The proposed range of TEa was wide, but generally ≤ 20%. The TEobs was < TEa for all variables and analyzers except for canine and feline HGB (high bias, low CV) and platelet counts (high bias, high CV). Overall, veterinary bench top analyzers fulfilled experts' requirements except for HGB due to method-related bias, and platelet counts due to known preanalytic/analytic issues. © 2016 American Society for Veterinary Clinical Pathology.

  9. Performance evaluation of Samsung LABGEO(HC10) Hematology Analyzer.

    Science.gov (United States)

    Park, Il Joong; Ahn, Sunhyun; Kim, Young In; Kang, Seon Joo; Cho, Sung Ran

    2014-08-01

    The Samsung LABGEO(HC10) Hematology Analyzer (LABGEO(HC10)) is a recently developed automated hematology analyzer that uses impedance technologies. The analyzer provides 18 parameters including 3-part differential at a maximum rate of 80 samples per hour. To evaluate the performance of the LABGEO(HC10). We evaluated precision, linearity, carryover, and relationship for complete blood cell count parameters between the LABGEO(HC10) and the LH780 (Beckman Coulter Inc) in a university hospital in Korea according to the Clinical and Laboratory Standards Institute guidelines. Sample stability and differences due to the anticoagulant used (K₂EDTA versus K₃EDTA) were also evaluated. The LABGEO(HC10) showed linearity over a wide range and minimal carryover ( 0.92) except for mean corpuscular hemoglobin concentration. The bias estimated was acceptable for all parameters investigated except for monocyte count. Most parameters were stable until 24 hours both at room temperature and at 4°C. The difference by anticoagulant type was statistically insignificant for all parameters except for a few red cell parameters. The accurate results achievable and simplicity of operation make the unit recommendable for small to medium-sized laboratories.

  10. Wavelength encoding technique for particle analyses in hematology analyzer

    Science.gov (United States)

    Rongeat, Nelly; Brunel, Patrick; Gineys, Jean-Philippe; Cremien, Didier; Couderc, Vincent; Nérin, Philippe

    2011-07-01

    The aim of this study is to combine multiple excitation wavelengths in order to improve accuracy of fluorescence characterization of labeled cells. The experimental demonstration is realized with a hematology analyzer based on flow cytometry and a CW laser source emitting two visible wavelengths. A given optical encoding associated to each wavelength allows fluorescence identification coming from specific fluorochromes and avoiding the use of noisy compensation method.

  11. Performance evaluation of the Sysmex® XE-2100D automated hematology analyzer

    Directory of Open Access Journals (Sweden)

    Tavany Elisa Santos Maciel

    2014-02-01

    Full Text Available Introduction: The Sysmex® XE-2100D is a multiparameter hematology analyzer designed for hematology testing in samples with ethylenediamine tetraacetic acid (EDTA. Objectives: Considering the importance of this hematology analyzer for clinical and laboratory practice, the objective of this study was to evaluate its analytical performance, comparing the obtained results with quality specifications described in literature. Material and method: In the evaluation of analytical performance, according to recommendations of the document H26-A2 of the Clinical and Laboratory Standards Institute (CLSI, intra-run imprecision, inter-run imprecision, linearity, carryover, autosampler evaluation, clinical sensitivity of the atypical lymphocytes flag (n = 400 samples were included, as well as the comparison between automated and manual leukocyte differential count (n = 400 samples, based on an adaptation of the document H20-A2 of CLSI. Results: Repeatability, reproducibility, linearity and carryover were satisfactory according to the manufacturer's specifications. The clinical sensitivity of the atypical lymphocytes flag showed efficiency, sensitivity and specificity of 92.5%, 65.2% and 94.1% respectively. The correlation coefficients between the automated and manual differential counts of neutrophils, lymphocytes, monocytes, eosinophils and basophils were 0.991, 0.99, 0.872, 0.974 and 0.557, respectively. Conclusions: The results were in accordance with quality specifications described in literature, indicating reliability in Sysmex® XE-2100D. This fact ensures certainty to both laboratory professionals and medical staff. We conclude that the Sysmex® XE-2100D showed excellent analytical performance, and is useful to provide reliable hematology data.

  12. ISO/IEC 17025 Sysmex R-500 hematology reticulocyte analyzer validation.

    Science.gov (United States)

    Dimopoulou, H A; Theodoridis, T; Galea, V; Christopoulou-Cokkinou, V; Spyridaki, M-H E; Georgakopoulos, C G

    2007-01-01

    The Sysmex R-500 (R-500) Hematology Analyzer is a bench-top system appropriate for the analysis of limited batches of blood samples. The R-500 provides percentage proportional (RET%), absolute reticulocyte (RET#), and absolute red blood cell (RBC#) counts. The system was validated at the Doping Control Laboratory of Athens, according to the International Committee for Standardization in Hematology, International Standards Organization (ISO/IEC) 17025, and World Antidoping Agency (WADA) specifications. The instrument calibration was performed according to the manufacturer and validation parameters comprised linearity, precision, uncertainty (intermediate and long-term precision), comparability, effect of drift, carryover, stability, and accuracy. The linearity and the comparability studies for RET#, RET%, and RBC# were expressed in regression factors (R2) and coefficients of correlation [r(x, y)], respectively. For the precision studies, the coefficients of variation for RET#, RET%, and RBC# were 9.49%, 9.83%, and ISO/IEC 17025 and WADA specifications.

  13. Objective evaluation of analyzer performance based on a retrospective meta-analysis of instrument validation studies: point-of-care hematology analyzers.

    Science.gov (United States)

    Cook, Andrea M; Moritz, Andreas; Freeman, Kathleen P; Bauer, Natali

    2017-06-01

    Information on quality requirements and objective evaluation of performance of veterinary point-of-care analyzers (POCAs) is scarce. The study was aimed at assessing observed total errors (TE obs s) for veterinary hematology POCAs via meta-analysis and comparing TE obs to allowable total error (TE a ) specifications based on experts' opinions. The TE obs for POCAs (impedance and laser-based) was calculated based on data from instrument validation studies published between 2006 and 2013 as follows: TE obs = 2 × CV [%] + bias [%]. The CV was taken from published studies; the bias was estimated from the regression equation at 2 different concentration levels of measurands. To fulfill quality requirements, TE obs should be 60% of analyzers showed TE obs hematology variables, respectively. For the CBC, TE obs was TE a (data from 3 analyzers). This meta-analysis is considered a pilot study. Experts' requirements (TE obs < TE a ) were fulfilled for most measurands except HGB (due to instrument-related bias for the ADVIA 2120) and platelet counts. Available data on the WBC differential count suggest an analytic bias, so nonstatistical quality control is recommended. © 2017 American Society for Veterinary Clinical Pathology.

  14. Oleophobic properties of the step-and-terrace sapphire surface

    Energy Technology Data Exchange (ETDEWEB)

    Muslimov, A. E., E-mail: amuslimov@mail.ru; Butashin, A. V.; Kanevsky, V. M. [Russian Academy of Sciences, Shubnikov Institute of Crystallography, Federal Research Center “Crystallography and Photonics” (Russian Federation)

    2017-03-15

    Sapphire is widely used in production of optical windows for various devices due to its mechanical and optical properties. However, during operation the surface can be affected by fats, oils, and other organic contaminations. Therefore, it is important to improve the oleophobic properties of sapphire windows. In this study, we investigate the interaction of a supersmooth sapphire surface with oleic acid droplets, which imitate human finger printing. It is established that chemical–mechanical polishing with additional annealing in air, which leads to the formation of an atomically smooth sapphire surface, makes it possible to significantly improve the oleophobic properties of the surface. The results are analyzed using the Ventsel–Deryagin homogeneous wetting model.

  15. Reliability improvement methods for sapphire fiber temperature sensors

    Science.gov (United States)

    Schietinger, C.; Adams, B.

    1991-08-01

    Mechanical, optical, electrical, and software design improvements can be brought to bear in the enhancement of fiber-optic sapphire-fiber temperature measurement tool reliability in harsh environments. The optical fiber thermometry (OFT) equipment discussed is used in numerous process industries and generally involves a sapphire sensor, an optical transmission cable, and a microprocessor-based signal analyzer. OFT technology incorporating sensors for corrosive environments, hybrid sensors, and two-wavelength measurements, are discussed.

  16. A Comparison of Mindray BC-6800, Sysmex XN-2000, and Beckman Coulter LH750 Automated Hematology Analyzers: A Pediatric Study.

    Science.gov (United States)

    Ciepiela, Olga; Kotuła, Iwona; Kierat, Szymon; Sieczkowska, Sandra; Podsiadłowska, Anna; Jenczelewska, Anna; Księżarczyk, Karolina; Demkow, Urszula

    2016-11-01

    Modern automated laboratory hematology analyzers allow the measurement of over 30 different hematological parameters useful in the diagnostic and clinical interpretation of patient symptoms. They use different methods to measure the same parameters. Thus, a comparison of complete blood count made by Mindray BC-6800, Sysmex XN-2000 and Beckman Coulter LH750 was performed. A comparison of results obtained by automated analysis of 807 anticoagulated blood samples from children and 125 manual microscopic differentiations were performed. This comparative study included white blood cell count, red blood cell count, and erythrocyte indices, as well as platelet count. The present study showed a poor level of agreement between white blood cell enumeration and differentiation of the three automated hematology analyzers under comparison. A very good agreement was found when comparing manual blood smear and automated granulocytes, monocytes, and lymphocytes differentiation. Red blood cell evaluation showed better agreement than white blood cells between the studied analyzers. To conclude, studied instruments did not ensure satisfactory interchangeability and did not facilitate a substitution of one analyzer by another. © 2016 Wiley Periodicals, Inc.

  17. High performance sapphire windows

    Science.gov (United States)

    Bates, Stephen C.; Liou, Larry

    1993-02-01

    High-quality, wide-aperture optical access is usually required for the advanced laser diagnostics that can now make a wide variety of non-intrusive measurements of combustion processes. Specially processed and mounted sapphire windows are proposed to provide this optical access to extreme environment. Through surface treatments and proper thermal stress design, single crystal sapphire can be a mechanically equivalent replacement for high strength steel. A prototype sapphire window and mounting system have been developed in a successful NASA SBIR Phase 1 project. A large and reliable increase in sapphire design strength (as much as 10x) has been achieved, and the initial specifications necessary for these gains have been defined. Failure testing of small windows has conclusively demonstrated the increased sapphire strength, indicating that a nearly flawless surface polish is the primary cause of strengthening, while an unusual mounting arrangement also significantly contributes to a larger effective strength. Phase 2 work will complete specification and demonstration of these windows, and will fabricate a set for use at NASA. The enhanced capabilities of these high performance sapphire windows will lead to many diagnostic capabilities not previously possible, as well as new applications for sapphire.

  18. Surface study of irradiated sapphires from Phrae Province, Thailand using AFM

    Science.gov (United States)

    Monarumit, N.; Jivanantaka, P.; Mogmued, J.; Lhuaamporn, T.; Satitkune, S.

    2017-09-01

    The irradiation is one of the gemstone enhancements for improving the gem quality. Typically, there are many varieties of irradiated gemstones in the gem market such as diamond, topaz, and sapphire. However, it is hard to identify the gemstones before and after irradiation. The aim of this study is to analyze the surface morphology for classifying the pristine and irradiated sapphires using atomic force microscope (AFM). In this study, the sapphire samples were collected from Phrae Province, Thailand. The samples were irradiated by high energy electron beam for a dose of ionizing radiation at 40,000 kGy. As the results, the surface morphology of pristine sapphires shows regular atomic arrangement, whereas, the surface morphology of irradiated sapphires shows the nano-channel observed by the 2D and 3D AFM images. The atomic step height and root mean square roughness have changed after irradiation due to the micro-structural defect on the sapphire surface. Therefore, this study is a frontier application for sapphire identification before and after irradiation.

  19. Polishing Sapphire Substrates by 355 nm Ultraviolet Laser

    Directory of Open Access Journals (Sweden)

    X. Wei

    2012-01-01

    Full Text Available This paper tries to investigate a novel polishing technology with high efficiency and nice surface quality for sapphire crystal that has high hardness, wear resistance, and chemical stability. A Q-switched 355 nm ultraviolet laser with nanosecond pulses was set up and used to polish sapphire substrate in different conditions in this paper. Surface roughness Ra of polished sapphire was measured with surface profiler, and the surface topography was observed with scanning electronic microscope. The effects of processing parameters as laser energy, pulse repetition rate, scanning speed, incident angle, scanning patterns, and initial surface conditions on surface roughness were analyzed.

  20. Spectroscopic properties for identifying sapphire samples from Ban Bo Kaew, Phrae Province, Thailand

    Science.gov (United States)

    Mogmued, J.; Monarumit, N.; Won-in, K.; Satitkune, S.

    2017-09-01

    Gemstone commercial is a high revenue for Thailand especially ruby and sapphire. Moreover, Phrae is a potential gem field located in the northern part of Thailand. The studies of spectroscopic properties are mainly to identify gemstone using advanced techniques (e.g. UV-Vis-NIR spectrophotometry, FTIR spectrometry and Raman spectroscopy). Typically, UV-Vis-NIR spectrophotometry is a technique to study the cause of color in gemstones. FTIR spectrometry is a technique to study the functional groups in gem-materials. Raman pattern can be applied to identify the mineral inclusions in gemstones. In this study, the natural sapphires from Ban Bo Kaew were divided into two groups based on colors including blue and green. The samples were analyzed by UV-Vis-NIR spectrophotometer, FTIR spectrometer and Raman spectroscope for studying spectroscopic properties. According to UV-Vis-NIR spectra, the blue sapphires show higher Fe3+/Ti4+ and Fe2+/Fe3+ absorption peaks than those of green sapphires. Otherwise, green sapphires display higher Fe3+/Fe3+ absorption peaks than blue sapphires. The FTIR spectra of both blue and green sapphire samples show the absorption peaks of -OH,-CH and CO2. The mineral inclusions such as ferrocolumbite and rutile in sapphires from this area were observed by Raman spectroscope. The spectroscopic properties of sapphire samples from Ban Bo Kaew, Phrae Province, Thailand are applied to be the specific evidence for gemstone identification.

  1. Evaluation of the URIT-2900 automated hematology analyzer for screening of thalassemia and hemoglobinopathies in Southeast Asian populations.

    Science.gov (United States)

    Karnpean, Rossarin; Pansuwan, Anupong; Fucharoen, Goonnapa; Fucharoen, Supan

    2011-07-01

    The effectiveness of the URIT-2900 Hematology Analyzer for screening of hemoglobinopathies commonly found in Southeast Asian populations was examined. Appropriate cut-off values of MCV and MCH for screening of α(0) and β thalassemias were derived from the receiver operator characteristic curve conducted initially on 279 subjects with various thalassemia genotypes. Validation was performed additionally in a cohort of another unrelated 313 subjects. The best cut off values of MCV and MCH were found to be 78fL and 27pg, respectively. Using these cut off values in combination with the dichlorophenolindophenol test in screening of α(0) thalassemia, β thalassemia and Hb E in a cohort study revealed 100% sensitivity, 79.6% specificity, 80.0% positive predictive value and 100% negative predictive value. The combined blood cell counting using the URIT-2900 Automated Hematology Analyzer and dichlorophenolindophenol test is suitable for population screening of thalassemia and hemoglobinopathies in Southeast Asia. Copyright © 2011 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Research Progress and Development of Sapphire Fiber Sensor

    Directory of Open Access Journals (Sweden)

    Guochang ZHAO

    2014-07-01

    Full Text Available Sapphire fiber thermometers have become a new potential option in the field of high-temperature measurements. Recent research progress of sapphire fiber sensors is summarized; operational principles, advantages, disadvantages, and applications of sapphire fiber sensors are introduced. Research has shown that sapphire fiber sensors can be used to accurately measure very high temperatures in harsh environments and has been widely applied in fields such as aviation, metallurgy, the chemical industry, energy, and other high temperature measurement areas. Sapphire optical fiber temperature measurement technology will move toward miniaturization, intelligence following the advances in materials, micro-fabrication and communication technologies.

  3. Neutron method for NDA in the Sapphire Project

    International Nuclear Information System (INIS)

    Lewis, K.D.

    1995-01-01

    The implementation of Project Sapphire, the top-secret mission to the Republic of Kazakhstan to recover weapons-grade nuclear materials, consisted of four major elements: (1) repacking of fissile material from Kazakh containers into suitable U.S. containers; (2) nondestructive analyses (NDA) to quantify the 235 U content of each container for nuclear criticality safety and compliance purposes; (3) packaging of the fissile material containers into 6M/2R drums, which are internationally approved for shipping fissile material; and (4) shipping or transport of the recovered fissile material to the United States. This paper discusses the development and application of a passive neutron counting technique used in the NDA phase of the Sapphire operations to analyze uranium/beryllium (U/Be) alloys and compounds for 235 U content

  4. Agreement of manual cell counts and automated counts of the scil Vet abc Plus(+) hematology analyzer for analysis of equine synovial fluid.

    Science.gov (United States)

    Van de Water, Eline; Oosterlinck, Maarten; Duchateau, Luc; Pille, Frederik

    2016-06-01

    The purpose of this study was to determine whether the scil Vet abc Plus(+) (SCIL Animal Care Company, Altorf, France), an impedance hematology analyzer, can accurately quantify and differentiate nucleated blood cells (NBCs) in equine synovial fluid. Synovial fluid samples (n=242) in different stages of experimentally induced inflammation were analyzed with and without hyaluronidase pretreatment and compared to manual hemocytometer counts and smear reviews. No significant effect of hyaluronidase pretreatment was observed. Total nucleated cell counts of the scil Vet abc Plus(+) were significantly higher compared to the manual method (P=0.02), yet the difference was small and clinically irrelevant (ratio manual/automated count equal to 0.97 with 95% CI [0.95, 1.00]). Differential cell counts of the scil Vet abc Plus(+) were not accurate. In conclusion, the scil Vet abc Plus(+) hematology analyzer is highly accurate for quantification, but not accurate for differentiation of NBCs in equine synovial fluid. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Neutron Transmission of Single-crystal Sapphire Filters

    Science.gov (United States)

    Adib, M.; Kilany, M.; Habib, N.; Fathallah, M.

    2005-05-01

    An additive formula is given that permits the calculation of the nuclear capture, thermal diffuse and Bragg scattering cross-sections as a function of sapphire temperature and crystal parameters. We have developed a computer program that allows calculations of the thermal neutron transmission for the sapphire rhombohedral structure and its equivalent trigonal structure. The calculated total cross-section values and effective attenuation coefficient for single-crystalline sapphire at different temperatures are compared with measured values. Overall agreement is indicated between the formula and experimental data. We discuss the use of sapphire single crystal as a thermal neutron filter in terms of the optimum cystal thickness, mosaic spread, temperature, cutting plane and tuning for efficient transmission of thermal-reactor neutrons.

  6. Neutron transmission of single-crystal sapphire filters

    International Nuclear Information System (INIS)

    Adib, M.; Kilany, M.; Habib, N.; Fathallah, M.

    2005-01-01

    An additive formula is given that permits the calculation of the nuclear capture, thermal diffuse and Bragg scattering cross-sections as a function of sapphire temperature and crystal parameters. We have developed a computer program that allows calculations of the thermal neutron transmission for the sapphire rhombohedral structure and its equivalent trigonal structure. The calculated total cross-section values and effective attenuation coefficient for single-crystalline sapphire at different temperatures are compared with measured values. Overall agreement is indicated between the formula fits and experimental data. We discuss the use of sapphire single crystal as a thermal neutron filter in terms of the optimum crystal thickness, mosaic spread, temperature, cutting plane and tuning for efficient transmission of thermal-reactor neutrons. (author)

  7. Neutron transmission of single-crystal sapphire filters

    International Nuclear Information System (INIS)

    Adib, M.; Kilany, M.; Habib, N.; Fathallah, M.

    2004-01-01

    A simple additive formula is given that permits the calculation of the nuclear capture, thermal diffuse and Bragg scattering cross-sections as a function of sapphire temperature and crystal parameters. We have developed a computer program that allows calculations of the thermal neutron transmission for the sapphire rhombohedral structure and its equivalent trigonal structure. The calculated total cross-section values and effective attenuation coefficient for mono-crystalline sapphire at different temperatures are compared with measured values. Overall agreement is indicated between the formula fits and experimental data. We discuss the use of sapphire single-crystal as a thermal neutron filter in terms of the optimum crystal thickness, mosaic spread, temperature, cutting plane and tuning for efficient transmission of thermal-reactor neutrons

  8. Reduced cost and improved figure of sapphire optical components

    Science.gov (United States)

    Walters, Mark; Bartlett, Kevin; Brophy, Matthew R.; DeGroote Nelson, Jessica; Medicus, Kate

    2015-10-01

    Sapphire presents many challenges to optical manufacturers due to its high hardness and anisotropic properties. Long lead times and high prices are the typical result of such challenges. The cost of even a simple 'grind and shine' process can be prohibitive. The high precision surfaces required by optical sensor applications further exacerbate the challenge of processing sapphire thereby increasing cost further. Optimax has demonstrated a production process for such windows that delivers over 50% time reduction as compared to traditional manufacturing processes for sapphire, while producing windows with less than 1/5 wave rms figure error. Optimax's sapphire production process achieves significant improvement in cost by implementation of a controlled grinding process to present the best possible surface to the polishing equipment. Following the grinding process is a polishing process taking advantage of chemical interactions between slurry and substrate to deliver excellent removal rates and surface finish. Through experiments, the mechanics of the polishing process were also optimized to produce excellent optical figure. In addition to reducing the cost of producing large sapphire sensor windows, the grinding and polishing technology Optimax has developed aids in producing spherical sapphire components to better figure quality. In addition to reducing the cost of producing large sapphire sensor windows, the grinding and polishing technology Optimax has developed aids in producing spherical sapphire components to better figure quality. Through specially developed polishing slurries, the peak-to-valley figure error of spherical sapphire parts is reduced by over 80%.

  9. Kerr-lens mode-locked Ti:Sapphire laser pumped by a single laser diode

    Science.gov (United States)

    Kopylov, D. A.; Esaulkov, M. N.; Kuritsyn, I. I.; Mavritskiy, A. O.; Perminov, B. E.; Konyashchenko, A. V.; Murzina, T. V.; Maydykovskiy, A. I.

    2018-04-01

    The performance of a Ti:sapphire laser pumped by a single 461 nm laser diode is presented for both the continuous-wave and the mode-locked regimes of operation. We introduce a simple astigmatism correction scheme for the laser diode beam consisting of two cylindrical lenses affecting the pump beam along the fast axis of the laser diode, which provides the mode-matching between the nearly square-shaped pump beam and the cavity mode. The resulting efficiency of the suggested Ti:Sapphire oscillator pumped by such a laser diode is analyzed for the Ti:sapphire crystals of 3 mm, 5 mm and 10 mm in length. We demonstrate that such a system provides the generation of ultrashort pulses up to 15 fs in duration with the repetition rate of 87 MHz, the average power being 170 mW.

  10. Sapphire capillary interstitial irradiators for laser medicine

    Science.gov (United States)

    Shikunova, I. A.; Dolganova, I. N.; Dubyanskaya, E. N.; Mukhina, E. E.; Zaytsev, K. I.; Kurlov, V. N.

    2018-04-01

    In this paper, we demonstrate instruments for laser radiation delivery based on sapphire capillary needles. Such sapphire irradiators (introducers) can be used for various medical applications, such as photodynamic therapy, laser hyperthermia, laser interstitial thermal therapy, and ablation of tumors of various organs. Unique properties of sapphire allow for effective redistribution of the heat, generated in biological tissues during their exposure to laser radiation. This leads to homogeneous distribution of the laser irradiation around the needle, and lower possibility of formation of the overheating focuses, as well as the following non-transparent thrombi.

  11. Sapphire: A kinking nonlinear elastic solid

    Science.gov (United States)

    Basu, S.; Barsoum, M. W.; Kalidindi, S. R.

    2006-03-01

    Kinking nonlinear elastic (KNE) solids are a recently identified large class of solids that deform fully reversibly by the formation of dislocation-based kink bands [Barsoum et al. Phys. Rev. Lett. 92, 255508 (2004)]. We further conjectured that a high c/a ratio-that ensures that only basal slip is operative-is a sufficient condition for a solid to be KNE. The c/a ratio of sapphire is 2.73 and thus, if our conjecture is correct, it should be a KNE solid. Herein by repeatedly loading-up to 30 times-the same location of sapphire single crystals of two orientations-A and C-with a 1 μm radius spherical nanoindenter, followed by atomic force microscopy, we showed that sapphire is indeed a KNE solid. After pop-ins of the order of 100 nm, the repeated loadings give rise to fully reversible, reproducible hysteresis loops wherein the energy dissipated per unit volume per cycle Wd is of the order of 0.5 GJ/m3. Wd is due to the back and fro motion of the dislocations making up the incipient kink bands that are fully reversible. The results presented here strongly suggest that-like in graphite and mica-kink bands play a more critical role in the room temperature constrained deformation of sapphire than had hitherto been appreciated. Our interpretation is also in agreement with, and can explain most, recent nanoindentation results on sapphire.

  12. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Hematology (including routine hematology and....941 Hematology (including routine hematology and coagulation). (a) Program content and frequency of challenge. To be approved for proficiency testing for hematology, a program must provide a minimum of five...

  13. A neutron method for NDA analysis in the SAPPHIRE Project

    International Nuclear Information System (INIS)

    Lewis, K.D.

    1995-01-01

    The implementation of Project SAPPHIRE, the top secret mission to the Republic of Kazakhstan to recover weapons grade nuclear materials, consisted of four major elements: (1) the re-packing of fissile material from Kazakh containers into suitable US containers; (2) nondestructive analyses (NDA) to quantify the U-235 content of each container for Nuclear Criticality Safety and compliance purposes; (3) the packaging of the fissile material containers into 6M/2R drums, which are internationally approved for shipping fissile material; and (4) the shipping or transport of the recovered fissile material to the United States. This paper discusses the development and application of a passive neutron counting technique used in the NDA phase of SAPPHIRE operations to analyze uranium/beryllium (U/Be) alloys and compounds for U-235 content

  14. Controllable laser thermal cleavage of sapphire wafers

    Science.gov (United States)

    Xu, Jiayu; Hu, Hong; Zhuang, Changhui; Ma, Guodong; Han, Junlong; Lei, Yulin

    2018-03-01

    Laser processing of substrates for light-emitting diodes (LEDs) offers advantages over other processing techniques and is therefore an active research area in both industrial and academic sectors. The processing of sapphire wafers is problematic because sapphire is a hard and brittle material. Semiconductor laser scribing processing suffers certain disadvantages that have yet to be overcome, thereby necessitating further investigation. In this work, a platform for controllable laser thermal cleavage was constructed. A sapphire LED wafer was modeled using the finite element method to simulate the thermal and stress distributions under different conditions. A guide groove cut by laser ablation before the cleavage process was observed to guide the crack extension and avoid deviation. The surface and cross section of sapphire wafers processed using controllable laser thermal cleavage were characterized by scanning electron microscopy and optical microscopy, and their morphology was compared to that of wafers processed using stealth dicing. The differences in luminous efficiency between substrates prepared using these two processing methods are explained.

  15. Hematologic emergencies

    Directory of Open Access Journals (Sweden)

    Daniele Vallisa

    2012-01-01

    Full Text Available In recent years, the surprising progress made in other areas of hematology (advances in the understanding of leukemogenesis, improved transplant techniques has been conspicuously absent in the management of hematologic emergencies. And yet, every step toward greater knowledge, every new treatment option will be of little value unless we are able to manage the acute complications of hematologic diseases. These complications are better defined as hematologic emergencies, and they are characterized by a high rate of mortality. This review is based on a search of the literature that was initially confined to articles published in the journal Hematology from 2000 to 2009. The search was then extended to the Cochrane Library and to Pub Med in February 2010 with the following Keywords emergencies; urgencies; hematology. The same key words were employed in a search of the archives of Blood and the New England Journal of Medicine from 2000 to 2010. The results confirm that hematologic emergencies can be caused by hematologic malignancies as well as by non-neoplastic hematologic diseases. Within the former category; this review examines the causes; manifestations; treatment and prevention of disseminated intravascular coagulation; superior vena caval syndrome; spinal cord compression; tumor lysis syndrome; hyperleukocytosis; and hypercalcemia. We also review emergency situations associated with non-neoplatic haematological diseases; such as thrombotic thrombocytopenic purpura; drug-induced hemolytic anemia; and acute sickle-cell crisis.

  16. The European Hematology Association Roadmap for European Hematology Research

    DEFF Research Database (Denmark)

    Engert, Andreas; Balduini, Carlo; Brand, Anneke

    2016-01-01

    The European Hematology Association (EHA) Roadmap for European Hematology Research highlights major achievements in diagnosis and treatment of blood disorders and identifies the greatest unmet clinical and scientific needs in those areas to enable better funded, more focused European hematology...... research. Initiated by the EHA, around 300 experts contributed to the consensus document, which will help European policy makers, research funders, research organizations, researchers, and patient groups make better informed decisions on hematology research. It also aims to raise public awareness...... of the burden of blood disorders on European society, which purely in economic terms is estimated at €23 billion per year, a level of cost that is not matched in current European hematology research funding. In recent decades, hematology research has improved our fundamental understanding of the biology...

  17. Leveraging Python Interoperability Tools to Improve Sapphire's Usability

    Energy Technology Data Exchange (ETDEWEB)

    Gezahegne, A; Love, N S

    2007-12-10

    The Sapphire project at the Center for Applied Scientific Computing (CASC) develops and applies an extensive set of data mining algorithms for the analysis of large data sets. Sapphire's algorithms are currently available as a set of C++ libraries. However many users prefer higher level scripting languages such as Python for their ease of use and flexibility. In this report, we evaluate four interoperability tools for the purpose of wrapping Sapphire's core functionality with Python. Exposing Sapphire's functionality through a Python interface would increase its usability and connect its algorithms to existing Python tools.

  18. Sapphire: Canada's Answer to Space-Based Surveillance of Orbital Objects

    Science.gov (United States)

    Maskell, P.; Oram, L.

    The Canadian Department of National Defence is in the process of developing the Canadian Space Surveillance System (CSSS) as the main focus of the Surveillance of Space (SofS) Project. The CSSS consists of two major elements: the Sapphire System and the Sensor System Operations Centre (SSOC). The space segment of the Sapphire System is comprised of the Sapphire Satellite - an autonomous spacecraft with an electro-optical payload which will act as a contributing sensor to the United States (US) Space Surveillance Network (SSN). It will operate in a circular, sunsynchronous orbit at an altitude of approximately 750 kilometers and image a minimum of 360 space objects daily in orbits ranging from 6,000 to 40,000 kilometers in altitude. The ground segment of the Sapphire System is composed of a Spacecraft Control Center (SCC), a Satellite Processing and Scheduling Facility (SPSF), and the Sapphire Simulator. The SPSF will be responsible for data transmission, reception, and processing while the SCC will serve to control and monitor the Sapphire Satellite. Surveillance data will be received from Sapphire through two ground stations. Following processing by the SPSF, the surveillance data will then be forwarded to the SSOC. The SSOC will function as the interface between the Sapphire System and the US Joint Space Operations Center (JSpOC). The JSpOC coordinates input from various sensors around the world, all of which are a part of the SSN. The SSOC will task the Sapphire System daily and provide surveillance data to the JSpOC for correlation with data from other SSN sensors. This will include orbital parameters required to predict future positions of objects to be tracked. The SSOC receives daily tasking instructions from the JSpOC to determine which objects the Sapphire spacecraft is required to observe. The advantage of this space-based sensor over ground-based telescopes is that weather and time of day are not factors affecting observation. Thus, space-based optical

  19. Spatial chirp in Ti:sapphire multipass amplifier

    International Nuclear Information System (INIS)

    Li Wenkai; Lu Jun; Li Yanyan; Guo Xiaoyang; Wu Fenxiang; Yu Linpeng; Wang Pengfei; Xu Yi; Leng Yuxin

    2017-01-01

    The spatial chirp generated in the Ti:sapphire multipass amplifier is numerically investigated based on the one-dimensional (1D) and two-dimensional (2D) Frantz–Nodvik equations. The simulation indicates that the spatial chirp is induced by the spatially inhomogeneous gain, and it can be almost eliminated by utilization of proper beam profiles and spot sizes of the signal and pump pulses, for example, the pump pulse has a top-hatted beam profile and the signal pulse has a super-Gaussian beam profile with a relatively larger spot size. In this way, a clear understanding of spatial chirp mechanisms in the Ti:sapphire multipass amplifier is proposed, therefore we can effectively almost eliminate the spatial chirp and improve the beam quality of a high-power Ti:sapphire chirped pulse amplifier system. (paper)

  20. A peek into the history of sapphire crystal growth

    Science.gov (United States)

    Harris, Daniel C.

    2003-09-01

    After the chemical compositions of sapphire and ruby were unraveled in the middle of the 19th century, chemists set out to grow artificial crystals of these valuable gemstones. In 1885 a dealer in Geneva began to sell ruby that is now believed to have been created by flame fusion. Gemnologists rapidly concluded that the stones were artificial, but the Geneva ruby stimulated A. V. L. Verneuil in Paris to develop a flame fusion process to produce higher quality ruby and sapphire. By 1900 there was brisk demand for ruby manufactured by Verneuil's method, even though Verneuil did not publicly announce his work until 1902 and did not publish details until 1904. The Verneuil process was used with little alteration for the next 50 years. From 1932-1953, S. K. Popov in the Soviet Union established a capability for manufacturing high quality sapphire by the Verneuil process. In the U.S., under government contract, Linde Air Products Co. implemented the Verneuil process for ruby and sapphire when European sources were cut off during World War II. These materials were essential to the war effort for jewel bearings in precision instruments. In the 1960s and 1970s, the Czochralski process was implemented by Linde and its successor, Union Carbide, to make higher crystal quality material for ruby lasers. Stimulated by a government contract for structural fibers in 1966, H. LaBelle invented edge-defined film-fed growth (EFG). The Saphikon company, which is currently owned by Saint-Gobain, evolved from this effort. Independently and simultaneously, Stepanov developed edge-defined film-fed growth in the Soviet Union. In 1967 F. Schmid and D. Viechnicki at the Army Materials Research Lab grew sapphire by the heat exchanger method (HEM). Schmid went on to establish Crystal Systems, Inc. around this technology. Rotem Industries, founded in Israel in 1969, perfected the growth of sapphire hemispheres and near-net-shape domes by gradient solidification. In the U.S., growth of near

  1. Nanostructured sapphire optical fiber for sensing in harsh environments

    Science.gov (United States)

    Chen, Hui; Liu, Kai; Ma, Yiwei; Tian, Fei; Du, Henry

    2017-05-01

    We describe an innovative and scalable strategy of transforming a commercial unclad sapphire optical fiber to an allalumina nanostructured sapphire optical fiber (NSOF) that overcomes decades-long challenges faced in the field of sapphire fiber optics. The strategy entails fiber coating with metal Al followed by subsequent anodization to form anodized alumina oxide (AAO) cladding of highly organized pore channel structure. We show that Ag nanoparticles entrapped in AAO show excellent structural and morphological stability and less susceptibility to oxidation for potential high-temperature surface-enhanced Raman Scattering (SERS). We reveal, with aid of numerical simulations, that the AAO cladding greatly increases the evanescent-field overlap both in power and extent and that lower porosity of AAO results in higher evanescent-field overlap. This work has opened the door to new sapphire fiber-based sensor design and sensor architecture.

  2. Hematological parameters in children with Down syndrome

    Directory of Open Access Journals (Sweden)

    Renato Nisihara

    2015-04-01

    Full Text Available Introduction: There are few studies that investigated whether Down syndrome (DS interferes with references values for complete blood counts (CBC test in children with the syndrome. Objective: This study aimed to analyze the results of CBC performed in children with DS. Patients and methods: Data from CBC of DS children were included; at the time of examination they were aged between 2 and 10 years and had no clinical signs and/or symptoms of infectious disease. The hematological parameters analyzed were: total number of erythrocytes (RBC, hemoglobin (Hb concentration, hematological indices, platelet count, and total number of leucocytes. Additionally, we compared the collected parameters according to gender and age of the children studied. Results: A total of 203 CBC (100 girls and 103 boys were evaluated. In general, no significant differences were observed in studied parameters between the values found in samples of DS children and the values described in the literature as a reference for children in this age group. No difference in the prevalence of anemia was observed in relation to gender (p = 0.33, 14/103 (13.6% boys, and 11/100 (11% girls had anemia. However, the Hb and hematological indices values found in boys was significantly lower than in girls (p < 0.001. Conclusion: This investigation is the first one in Brazil to present and analyze the CBC results of DS children, reporting that their hematological indices are within the expected range for children without DS. Additionally, it was found that 12.3% of them had anemia.

  3. Temperature-modulated annealing of c-plane sapphire for long-range-ordered atomic steps

    International Nuclear Information System (INIS)

    Yatsui, Takashi; Kuribara, Kazunori; Sekitani, Tsuyoshi; Someya, Takao; Yoshimoto, Mamoru

    2016-01-01

    High-quality single-crystalline sapphire is used to prepare various semiconductors because of its thermal stability. Here, we applied the tempering technique, which is well known in the production of chocolate, to prepare a sapphire substrate. Surprisingly, we successfully realised millimetre-range ordering of the atomic step of the sapphire substrate. We also obtained a sapphire atomic step with nanometre-scale uniformity in the terrace width and atomic-step height. Such sapphire substrates will find applications in the preparation of various semiconductors and devices. (paper)

  4. Single-Crystal Sapphire Optical Fiber Sensor Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Pickrell, Gary [Virginia Polytechnic Inst. & State Univ., Blacksburg, VA (United States); Scott, Brian [Virginia Polytechnic Inst. & State Univ., Blacksburg, VA (United States); Wang, Anbo [Virginia Polytechnic Inst. & State Univ., Blacksburg, VA (United States); Yu, Zhihao [Virginia Polytechnic Inst. & State Univ., Blacksburg, VA (United States)

    2013-12-31

    This report summarizes technical progress on the program “Single-Crystal Sapphire Optical Fiber Sensor Instrumentation,” funded by the National Energy Technology Laboratory of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. This project was completed in three phases, each with a separate focus. Phase I of the program, from October 1999 to April 2002, was devoted to development of sensing schema for use in high temperature, harsh environments. Different sensing designs were proposed and tested in the laboratory. Phase II of the program, from April 2002 to April 2009, focused on bringing the sensor technologies, which had already been successfully demonstrated in the laboratory, to a level where the sensors could be deployed in harsh industrial environments and eventually become commercially viable through a series of field tests. Also, a new sensing scheme was developed and tested with numerous advantages over all previous ones in Phase II. Phase III of the program, September 2009 to December 2013, focused on development of the new sensing scheme for field testing in conjunction with materials engineering of the improved sensor packaging lifetimes. In Phase I, three different sensing principles were studied: sapphire air-gap extrinsic Fabry-Perot sensors; intensity-based polarimetric sensors; and broadband polarimetric sensors. Black body radiation tests and corrosion tests were also performed in this phase. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. At the beginning of Phase II, in June 2004, the BPDI sensor was tested at the Wabash River coal gasifier

  5. Facet Appearance on the Lateral Face of Sapphire Single-Crystal Fibers during LHPG Growth

    Directory of Open Access Journals (Sweden)

    Liudmila D. Iskhakova

    2016-08-01

    Full Text Available Results of the study of the lateral surface of single-crystal (SC sapphire fibers grown along crystallographic directions [ 0001 ] and [ 11 2 ¯ 0 ] by the LHPG method are presented. The appearance or absence of faceting of the lateral surface of the fibers depending on the growth direction is analyzed. The crystallographic orientation of the facets is investigated. The microstructure of the samples is investigated with the help of an optical microscope and a JSM-5910LV scanning electronic microscope (JEOL. The crystallographic orientations of the facets on the SC sapphire fiber surface are determined by electron backscatter diffraction (EBSD. The seed orientation is studied by means of XRD techniques.

  6. Semipolar GaN grown on m-plane sapphire using MOVPE

    Energy Technology Data Exchange (ETDEWEB)

    Wernicke, Tim; Netzel, Carsten; Weyers, Markus [Ferdinand-Braun-Institut fuer Hoechstfrequenztechnik, Berlin (Germany); Kneissl, Michael [Ferdinand-Braun-Institut fuer Hoechstfrequenztechnik, Berlin (Germany); Institute of Solid State Physics, Technical University of Berlin (Germany)

    2008-07-01

    We have investigated the MOVPE growth of semipolar gallium nitride (GaN) films on (10 anti 1 0) m-plane sapphire substrates. Specular GaN films with a RMS roughness (10 x 10 {mu}m{sup 2}) of 15.2 nm were obtained and an arrowhead like structure aligned along[ anti 2 113] is prevailing. The orientation relationship was determined by XRD and yielded (212){sub GaN} parallel (10 anti 10){sub sapphire} and [anti 2113]{sub GaN} parallel [0001]{sub sapphire} as well as [anti 2113]{sub GaN} parallel [000 anti 1]{sub sapphire}. PL spectra exhibited near band edge emission accompanied by a strong basal plane stacking fault emission. In addition lower energy peaks attributed to prismatic plane stacking faults and donor acceptor pair emission appeared in the spectrum. With similar growth conditions also (1013) GaN films on m-plane sapphire were obtained. In the later case we found that the layer was twinned, crystallites with different c-axis orientation were present. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  7. Order in nanometer thick intergranular films at Au-sapphire interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Baram, Mor [Department of Materials Engineering, Technion-Israel Institute of Technology, Haifa 32000 (Israel); Garofalini, Stephen H. [Department of Materials Science and Engineering, Rutgers University, Piscataway, NJ 08854-8065 (United States); Kaplan, Wayne D., E-mail: kaplan@tx.technion.ac.il [Department of Materials Engineering, Technion-Israel Institute of Technology, Haifa 32000 (Israel)

    2011-08-15

    Highlights: {yields} Au particles were equilibrated on (0 0 0 1) sapphire in the presence of anorthite. {yields} 1.2 nm thick equilibrium films (complexions) were formed at the Au-sapphire interfaces. {yields} Quantitative HRTEM was used to study the atomistic structure of the films. {yields} Structural order was observed in the 1.2 nm thick films adjacent to the sapphire crystal. {yields} This demonstrates that ordering is an intrinsic part of equilibrium intergranular films. - Abstract: In recent years extensive studies on interfaces have shown that {approx}1 nm thick intergranular films (IGF) exist at interfaces in different material systems, and that IGF can significantly affect the materials' properties. However, there is great deal of uncertainty whether such films are amorphous or partially ordered. In this study specimens were prepared from Au particles that were equilibrated on sapphire substrates in the presence of anorthite glass, leading to the formation of 1.2 nm thick IGF at the Au-sapphire interfaces. Site-specific cross-section samples were characterized using quantitative high resolution transmission electron microscopy to study the atomistic structure of the films. Order was observed in the 1.2 nm thick films adjacent to the sapphire crystal in the form of 'Ca cages', experimentally demonstrating that ordering is an intrinsic part of IGF, as predicted from molecular dynamics and diffuse interface theory.

  8. BMC Blood Disorders becomes BMC Hematology: evolving along with the hematology field

    OpenAIRE

    Chap, Christna

    2013-01-01

    This Editorial marks the launch of BMC Hematology, formerly known as BMC Blood Disorders, within the BMC series of journals published by BioMed Central. The scope of BMC Hematology encompasses basic, experimental and clinical research related to hematology. In this Editorial we will discuss the rationale behind this relaunch and how, as an open access journal providing unrestricted and free access to scientific and scholarly work, BMC Hematology will help disseminate research in the hematolog...

  9. Comparison study of the rates of manual peripheral blood smear review from 3 automated hematology analyzers, Unicel DxH 800, ADVIA 2120i, and XE 2100, using international consensus group guidelines.

    Science.gov (United States)

    Kim, Sue Jung; Kim, Yoonjung; Shin, Saeam; Song, Jaewoo; Choi, Jong Rak

    2012-11-01

    In the clinical laboratory, it is important both to reduce the number of peripheral blood slide reviews to save time and money and to avoid reporting false results. To determine differences in the slide review rates of 3 widely used automated hematologic analyzers, the Unicel DxH 800 (Beckman Coulter Inc, Fullerton, California), ADVIA 2120i (Siemens Diagnostics, Tarrytown, New York), and XE 2100 (Sysmex, Kobe, Japan), using International Consensus Group for Hematology Review guidelines. A total of 1485 samples were tested, and 300 were manually reviewed. Slide review rates, sensitivity, specificity, and false-positive and false-negative rates were estimated using consensus group rules and compared using χ(2) tests, Fisher exact tests, or generalized estimating equations. Unicel DxH 800, ADVIA 2120i, and XE 2100 showed 22.8%, 20.2%, and 28.6% slide review rates; 14.3%, 14.3%, and 9.7% false-negative rates; and 13.7, 11.3%, and 17.3% false-positive rates, respectively. All analyzers showed significantly higher false-negative rates than that of the consensus group (2.9%). False-negative rates were higher than the recommended levels. Among 3 automated hematologic analyzers, XE 2100 showed the highest rate of slide review. Because the present study clearly shows that the slide review rates have distinct characteristics among the studied analyzers, each individual laboratory should consider selecting the most appropriate analyzer according to clinical characteristics. Analyzers with high sensitivity may be advantageous in outpatient settings for screening patients, whereas analyzers with high specificity may be beneficial in inpatient settings for efficient patient care.

  10. BMC Blood Disorders becomes BMC Hematology: evolving along with the hematology field.

    Science.gov (United States)

    Chap, Christna

    2013-04-10

    This Editorial marks the launch of BMC Hematology, formerly known as BMC Blood Disorders, within the BMC series of journals published by BioMed Central. The scope of BMC Hematology encompasses basic, experimental and clinical research related to hematology. In this Editorial we will discuss the rationale behind this relaunch and how, as an open access journal providing unrestricted and free access to scientific and scholarly work, BMC Hematology will help disseminate research in the hematology field in a freely-accessible manner.

  11. Analysis and modification of blue sapphires from Rwanda by ion beam techniques

    International Nuclear Information System (INIS)

    Bootkul, D.; Chaiwai, C.; Tippawan, U.; Wanthanachaisaeng, B.; Intarasiri, S.

    2015-01-01

    Highlights: • Ion beam analysis is an effective method for detecting trace elements. • Ion beam treatment is able to improve optical and color appearances of the blue sapphire from Rwanda. • These alternative methods can be extended to jewelry industry for large scale application. - Abstract: Blue sapphire is categorised in a corundum (Al_2O_3) group. The gems of this group are always amazed by their beauties and thus having high value. In this study, blue sapphires from Rwanda, recently came to Thai gemstone industry, are chosen for investigations. On one hand, we have applied Particle Induced X-ray Emission (PIXE), which is a highly sensitive and precise analytical technique that can be used to identify and quantify trace elements, for chemical analysis of the sapphires. Here we have found that the major element of blue sapphires from Rwanda is Al with trace elements such as Fe, Ti, Cr, Ga and Mg as are commonly found in normal blue sapphire. On the other hand, we have applied low and medium ion implantations for color improvement of the sapphire. It seems that a high amount of energy transferring during cascade collisions have altered the gems properties. We have clearly seen that the blue color of the sapphires have been intensified after nitrogen ion bombardment. In addition, the gems were also having more transparent and luster. The UV–Vis–NIR measurement detected the modification of their absorption properties, implying of the blue color increasing. Here the mechanism of these modifications is postulated and reported. In any point of view, the bombardment by using nitrogen ion beam is a promising technique for quality improvement of the blue sapphire from Rwanda.

  12. Analysis and modification of blue sapphires from Rwanda by ion beam techniques

    Science.gov (United States)

    Bootkul, D.; Chaiwai, C.; Tippawan, U.; Wanthanachaisaeng, B.; Intarasiri, S.

    2015-12-01

    Blue sapphire is categorised in a corundum (Al2O3) group. The gems of this group are always amazed by their beauties and thus having high value. In this study, blue sapphires from Rwanda, recently came to Thai gemstone industry, are chosen for investigations. On one hand, we have applied Particle Induced X-ray Emission (PIXE), which is a highly sensitive and precise analytical technique that can be used to identify and quantify trace elements, for chemical analysis of the sapphires. Here we have found that the major element of blue sapphires from Rwanda is Al with trace elements such as Fe, Ti, Cr, Ga and Mg as are commonly found in normal blue sapphire. On the other hand, we have applied low and medium ion implantations for color improvement of the sapphire. It seems that a high amount of energy transferring during cascade collisions have altered the gems properties. We have clearly seen that the blue color of the sapphires have been intensified after nitrogen ion bombardment. In addition, the gems were also having more transparent and luster. The UV-Vis-NIR measurement detected the modification of their absorption properties, implying of the blue color increasing. Here the mechanism of these modifications is postulated and reported. In any point of view, the bombardment by using nitrogen ion beam is a promising technique for quality improvement of the blue sapphire from Rwanda.

  13. Interfacial reactions between sapphire and Ag–Cu–Ti-based active braze alloys

    International Nuclear Information System (INIS)

    Ali, Majed; Knowles, Kevin M.; Mallinson, Phillip M.; Fernie, John A.

    2016-01-01

    The interfacial reactions between two commercially available Ag–Cu–Ti-based active braze alloys and sapphire have been studied. In separate experiments, Ag–35.3Cu–1.8Ti wt.% and Ag–26.7Cu–4.5Ti wt.% alloys have been sandwiched between pieces of R-plane orientated sapphire and heated in argon to temperatures between 750 and 900 °C for 1 min. The phases at the Ag–Cu–Ti/sapphire interfaces have been studied using selected area electron diffraction, energy dispersive X-ray spectroscopy and electron energy loss spectroscopy. Gradual and subtle changes at the Ag–Cu–Ti/sapphire interfaces were observed as a function of temperature, along with the formation of a transient phase that permitted wetting of the sapphire. Unequivocal evidence is shown that when the active braze alloys melt, titanium first migrates to the sapphire and reacts to dissolve up to ∼33 at.% oxygen, forming a nanometre-size polycrystalline layer with a chemical composition of Ti 2 O 1–x (x ≪ 1). Ti 3 Cu 3 O particles subsequently nucleate behind the Ti 2 O 1–x layer and grow to become a continuous micrometre-size layer, replacing the Ti 2 O 1–x layer. Finally at 845 °C, a nanometre-size γ-TiO layer forms on the sapphire to leave a typical interfacial structure of Ag–Cu/Ti 3 Cu 3 O/γ-TiO/sapphire consistent with that seen in samples of polycrystalline alumina joined to itself with these active braze alloys. These experimental observations have been used to establish a definitive bonding mechanism for the joining of sapphire with Ag–Cu alloys activated by small amounts of titanium.

  14. Analysis and modification of blue sapphires from Rwanda by ion beam techniques

    Energy Technology Data Exchange (ETDEWEB)

    Bootkul, D., E-mail: mo_duangkhae@hotmail.com [Department of General Science - Gems & Jewelry, Faculty of Science, Srinakharinwirot University, Bangkok 10110 (Thailand); Chaiwai, C.; Tippawan, U. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Wanthanachaisaeng, B. [Gems Enhancement Research Unit, Faculty of Gems, Burapha University, Chanthaburi Campus, Chanthaburi 22170 (Thailand); Intarasiri, S., E-mail: saweat@gmail.com [Science and Technology Research Institute, Chiang Mai University, Chiang Mai 50200 (Thailand)

    2015-12-15

    Highlights: • Ion beam analysis is an effective method for detecting trace elements. • Ion beam treatment is able to improve optical and color appearances of the blue sapphire from Rwanda. • These alternative methods can be extended to jewelry industry for large scale application. - Abstract: Blue sapphire is categorised in a corundum (Al{sub 2}O{sub 3}) group. The gems of this group are always amazed by their beauties and thus having high value. In this study, blue sapphires from Rwanda, recently came to Thai gemstone industry, are chosen for investigations. On one hand, we have applied Particle Induced X-ray Emission (PIXE), which is a highly sensitive and precise analytical technique that can be used to identify and quantify trace elements, for chemical analysis of the sapphires. Here we have found that the major element of blue sapphires from Rwanda is Al with trace elements such as Fe, Ti, Cr, Ga and Mg as are commonly found in normal blue sapphire. On the other hand, we have applied low and medium ion implantations for color improvement of the sapphire. It seems that a high amount of energy transferring during cascade collisions have altered the gems properties. We have clearly seen that the blue color of the sapphires have been intensified after nitrogen ion bombardment. In addition, the gems were also having more transparent and luster. The UV–Vis–NIR measurement detected the modification of their absorption properties, implying of the blue color increasing. Here the mechanism of these modifications is postulated and reported. In any point of view, the bombardment by using nitrogen ion beam is a promising technique for quality improvement of the blue sapphire from Rwanda.

  15. Ti:Sapphire waveguide lasers

    NARCIS (Netherlands)

    Pollnau, Markus; Pashinin, P.P.; Grivas, C.; Laversenne, L.; Wilkinson, J.S.; Eason, R.W.; Shepherd, D.P.

    2007-01-01

    Titanium-doped sapphire is one of the most prominent laser materials and is appreciated for its excellent heat conductivity and broadband gain spectrum, allowing for a wide wavelength tunability and generation of ultrashort pulses. As one of the hardest materials, it can also serve as a model system

  16. Superconducting accelerometer using niobium-on-sapphire rf resonator

    International Nuclear Information System (INIS)

    Blair, D.G.

    1979-01-01

    An accelerometer is described which uses a rf niobium-on-sapphire resonator as its sensor element. The accelerometer uses a magnetically levitated spool as a test mass and the spool modulates the inductance of the resonator; its position is servo controlled to maintain the resonator at the external rf excitation frequency. The accelerometer has high sensitivity over the full audio frequency range, but is optimized for frequencies between 100 Hz and 1 kHz, where the calculated displacement sensitivity approaches 10 -15 cm for a 1 Hz measurement bandwidth. The system noise sources are analyzed and possible improvements are discussed

  17. Characteristics of surface acoustic waves in (11\\bar 2 0)ZnO film/ R-sapphire substrate structures

    Science.gov (United States)

    Wang, Yan; Zhang, ShuYi; Xu, Jing; Xie, YingCai; Lan, XiaoDong

    2018-02-01

    (11\\bar 2 0)ZnO film/ R-sapphire substrate structure is promising for high frequency acoustic wave devices. The propagation characteristics of SAWs, including the Rayleigh waves along [0001] direction and Love waves along [1ī00] direction, are investigated by using 3 dimensional finite element method (3D-FEM). The phase velocity ( v p), electromechanical coupling coefficient ( k 2), temperature coefficient of frequency ( TCF) and reflection coefficient ( r) of Rayleigh wave and Love wave devices are theoretically analyzed. Furthermore, the influences of ZnO films with different crystal orientation on SAW properties are also investigated. The results show that the 1st Rayleigh wave has an exceedingly large k 2 of 4.95% in (90°, 90°, 0°) (11\\bar 2 0)ZnO film/ R-sapphire substrate associated with a phase velocity of 5300 m/s; and the 0th Love wave in (0°, 90°, 0°) (11\\bar 2 0)ZnO film/ R-sapphire substrate has a maximum k 2 of 3.86% associated with a phase velocity of 3400 m/s. And (11\\bar 2 0)ZnO film/ R-sapphire substrate structures can be used to design temperature-compensated and wide-band SAW devices. All of the results indicate that the performances of SAW devices can be optimized by suitably selecting ZnO films with different thickness and crystal orientations deposited on R-sapphire substrates.

  18. The European Hematology Association Roadmap for European Hematology Research : A consensus document

    NARCIS (Netherlands)

    Engert, Andreas; Balduini, Carlo; Brand, Anneke; Coiffier, Bertrand; Cordonnier, Catherine; Döhner, Hartmut; de Wit, Thom Duyvené; Eichinger, Sabine; Fibbe, Willem; Green, Tony; de Haas, Fleur; Iolascon, Achille; Jaffredo, Thierry; Rodeghiero, Francesco; Salles, Gilles; Schuringa, Jan Jacob

    The European Hematology Association (EHA) Roadmap for European Hematology Research highlights major achievements in diagnosis and treatment of blood disorders and identifies the greatest unmet clinical and scientific needs in those areas to enable better funded, more focused European hematology

  19. PRELIMINARY STUDY OF HEMATOLOGICAL PARAMETERS IN HERZEGOVINIAN DONKEY

    Directory of Open Access Journals (Sweden)

    Dunja Rukavina

    2016-02-01

    Full Text Available Herzegovinian donkey is a very important animal resource of Bosnia and Herzegovina. There have been no works attempted at determining the normal values of hematological parameters of Herzegovinian donkey. For this reason, the objective of the present study was to investigate some hematological parameters in Herzegovinian donkey. The research was performed on 30 apparently healthy donkeys (18 female and 12 male of ages from 1 to 20 years. Blood samples (3 ml were obtained by jugular vein puncture (vena jugularis externa in vacuum tubes with EDTA. The mean value of hematocrit was 29.19 %, hemoglobin concentration 10.6 g/dl, mean corpuscular hemoglobin concentration 36.33 g/dl, white blood cells 9.33 x109/L, granulocytes (109/L 5.45 x109/L, granulocytes (% 59.47%, lymphocyte/monocyte (109/L 3.89 x109/L, lymphocyte/monocyte (% 40.53% and platelet cells 148.97 x109/L. Parameters were determined using an automated analyzer IDEXX QBC VET AutoRead. Data were analyzed by SPSS V 15. All hematological parameters (except platelet cells were consistent with the recommended reference ranges for donkeys, and the values found in literature so far. Platelet cells values were much lower than in the literature for the other donkey breeds and the recommended reference ranges for donkeys. The slight differences found between our results and those reported in the previous works confirm the need for further studies to investigate the reference values of hematological parameters of Herzegovinian donkey. This work is a contribution to the study of hematological parameters of Herzegovinian donkey, and we expect these data to be applied to the further studies.

  20. Nonlinearity Mechanism and Correction of Sapphire Fiber Temperature Sensor on Blackbody Cavity

    Directory of Open Access Journals (Sweden)

    Tiejun Cao

    2014-06-01

    Full Text Available Based on the principle of blackbody radiation, sapphire optic fiber temperature sensor has been more widely used in recent years, and its temperature range is between 800 ~ 2000 oC, and the response time is in 10-2 magnitude, and transient temperature measurement can be high precision in harsh environments. Nonlinear constraints on sapphire fiber temperature sensor affect the accuracy and stability of the sensor. In order to solve the nonlinear problems which exist in the measurement, at first, the sapphire fiber optic temperature sensor temperature measurement principle and nonlinear generation mechanism are studied; secondly piecewise linear interpolation and spline interpolation linearization algorithm is designed with combining the nonlinear characteristics of sapphire optical fiber temperature sensor, and the program is designed on its linear and associated signal processing. Experimental results show that a good linearization of sapphire fiber optic temperature sensor can been achieved in this method.

  1. 'Sapphire' project. Objectives and outcomes

    International Nuclear Information System (INIS)

    Shkolnik, V.S.

    1997-01-01

    'Sapphire' Project contains the US assistance in purchasing/exporting 600 kg of highly enriched uranium from the State Holding Association 'Ulba' Uranium Plant, and compensatory equipment and service deliveries under the mutually concerted list. The compensatory payments were as separate projects in conformity with Kazakhstan enterprises needs, participation quota of which was determined by the Kazakhstan Government. Realization Milestones. Activity on Separate Projects: - basic 'Sapphire' part includes medical projects; - Kazakhstan Services were equipped with computers by the American International Development Agency for Taxation Services of Kazakhstan and by US Department of Energy for Monitoring preparation of Kazakhstan Atomic energy Agency. - 7 Research projects are being realized via the International Science and Technological Center; - export control. It has been realized as the equipment delivery under the concerted list; - equipping of nuclear materials accounting and control system at 'Ulba' Association enterprises

  2. Frequency-doubled diode laser for direct pumping of Ti:sapphire lasers

    DEFF Research Database (Denmark)

    Müller, André; Jensen, Ole Bjarlin; Unterhuber, Angelika

    2012-01-01

    . However, the superior electro-optical efficiency of the diode laser improves the overall efficiency of the Ti:sapphire laser by a factor > 2. The optical spectrum emitted by the Ti:sapphire laser shows a spectral width of 112 nm (FWHM). Based on autocorrelation measurements, pulse widths of less than 20...... fs are measured. These results open the opportunity of establishing diode laser pumped Ti:sapphire lasers for e.g. biophotonic applications like retinal optical coherence tomography or pumping of photonic crystal fibers for CARS microscopy.......A single-pass frequency doubled high-power tapered diode laser emitting nearly 1.3 W of green light suitable for direct pumping of Ti:sapphire lasers generating ultrashort pulses is demonstrated. The pump efficiencies reached 75 % of the values achieved with a commercial solid-state pump laser...

  3. Determinants of hematology-oncology trainees' postfellowship career pathways with a focus on nonmalignant hematology

    Science.gov (United States)

    Jenkins, Sarah; Mikhael, Joseph; Gitlin, Scott D.

    2018-01-01

    Nonmalignant hematologic conditions are extremely prevalent and contribute significantly to the global burden of disease. The US health care system may soon face a shortage of specialists in nonmalignant hematology. We sought to identify factors that lead hematology-oncology fellows to pursue (or not to pursue) careers in nonmalignant hematology. Cross-sectional, web-based survey distributed to 149 graduates of a hematology-oncology fellowship program at a large academic medical center between 1998 and 2016. Eighty-six out of 149 graduates responded (57.7%); most (59 [68.6%]) practice at an academic medical center. Respondents spend a mean of 61% of their time in clinical practice, 23.7% conducting research, 5.2% in education, and 5.2% in administration. Those in clinical practice spend a mean of 52.1% of their time in solid tumor oncology, 37.5% in hematologic malignancies, and 10% in nonmalignant hematology; only 1 spent >50% of time practicing nonmalignant hematology. Factors most significantly affecting choice of patient population included clinical experience during fellowship and intellectual stimulation of the patient population/disease type. Factors that could have most significantly influenced a decision to spend more time in nonmalignant hematology included increased exposure/access to role models and mentors and opportunities for better career growth/advancement. Fellowship graduates spend >50% of their time in clinical practice, but almost none spend a significant amount of time practicing nonmalignant hematology. Given the growing number of patients with nonmalignant hematologic conditions and a possible future provider shortage, medical trainees should be encouraged to pursue careers in nonmalignant hematology. PMID:29463548

  4. The European Hematology Association Roadmap for European Hematology Research: a consensus document.

    Science.gov (United States)

    Engert, Andreas; Balduini, Carlo; Brand, Anneke; Coiffier, Bertrand; Cordonnier, Catherine; Döhner, Hartmut; de Wit, Thom Duyvené; Eichinger, Sabine; Fibbe, Willem; Green, Tony; de Haas, Fleur; Iolascon, Achille; Jaffredo, Thierry; Rodeghiero, Francesco; Salles, Gilles; Schuringa, Jan Jacob

    2016-02-01

    The European Hematology Association (EHA) Roadmap for European Hematology Research highlights major achievements in diagnosis and treatment of blood disorders and identifies the greatest unmet clinical and scientific needs in those areas to enable better funded, more focused European hematology research. Initiated by the EHA, around 300 experts contributed to the consensus document, which will help European policy makers, research funders, research organizations, researchers, and patient groups make better informed decisions on hematology research. It also aims to raise public awareness of the burden of blood disorders on European society, which purely in economic terms is estimated at €23 billion per year, a level of cost that is not matched in current European hematology research funding. In recent decades, hematology research has improved our fundamental understanding of the biology of blood disorders, and has improved diagnostics and treatments, sometimes in revolutionary ways. This progress highlights the potential of focused basic research programs such as this EHA Roadmap.The EHA Roadmap identifies nine 'sections' in hematology: normal hematopoiesis, malignant lymphoid and myeloid diseases, anemias and related diseases, platelet disorders, blood coagulation and hemostatic disorders, transfusion medicine, infections in hematology, and hematopoietic stem cell transplantation. These sections span 60 smaller groups of diseases or disorders.The EHA Roadmap identifies priorities and needs across the field of hematology, including those to develop targeted therapies based on genomic profiling and chemical biology, to eradicate minimal residual malignant disease, and to develop cellular immunotherapies, combination treatments, gene therapies, hematopoietic stem cell treatments, and treatments that are better tolerated by elderly patients. Copyright© Ferrata Storti Foundation.

  5. Hematology

    International Nuclear Information System (INIS)

    Konrad, H.

    1976-01-01

    The latest state of nuclear medical functional diagnostics in hematology is reviewed. In addition to methods for determining the blood volume, iron kinetics, the survival time of erythrocytes as well as resorption and serum levels of vitamin B 12 kinetic investigations of thrombocytes, granulocytes, lymphocytes, and the spleen with the aid of radioisotopes are described in detail. Also included are tables with data about radiation doses to patients due to medical application of radioisotopes as well as a compilation of physical properties of radioisotopes which are used in hematological diagnosis such as 59 Fe, 51 Cr, 131 I, 125 I, 58 Co, 57 Co, 32 P, 3 H, sup(99m)Tc, 113 In. Finally, radiopharmaceuticals for hematological diagnostics are listed, which are commercially available in the German Democratic Republic. The booklet is intended for physicians working in outpatient departments and hospitals

  6. Optimizing Ti:Sapphire laser for quantitative biomedical imaging

    Science.gov (United States)

    James, Jeemol; Thomsen, Hanna; Hanstorp, Dag; Alemán Hérnandez, Felipe Ademir; Rothe, Sebastian; Enger, Jonas; Ericson, Marica B.

    2018-02-01

    Ti:Sapphire lasers are powerful tools in the field of scientific research and industry for a wide range of applications such as spectroscopic studies and microscopic imaging where tunable near-infrared light is required. To push the limits of the applicability of Ti:Sapphire lasers, fundamental understanding of the construction and operation is required. This paper presents two projects, (i) dealing with the building and characterization of custom built tunable narrow linewidth Ti:Sapphire laser for fundamental spectroscopy studies; and the second project (ii) the implementation of a fs-pulsed commercial Ti:Sapphire laser in an experimental multiphoton microscopy platform. For the narrow linewidth laser, a gold-plated diffraction grating with a Littrow geometry was implemented for highresolution wavelength selection. We demonstrate that the laser is tunable between 700 to 950 nm, operating in a pulsed mode with a repetition rate of 1 kHz and maximum average output power around 350 mW. The output linewidth was reduced from 6 GHz to 1.5 GHz by inserting an additional 6 mm thick etalon. The bandwidth was measured by means of a scanning Fabry Perot interferometer. Future work will focus on using a fs-pulsed commercial Ti:Sapphire laser (Tsunami, Spectra physics), operating at 80 MHz and maximum average output power around 1 W, for implementation in an experimental multiphoton microscopy set up dedicated for biomedical applications. Special focus will be on controlling pulse duration and dispersion in the optical components and biological tissue using pulse compression. Furthermore, time correlated analysis of the biological samples will be performed with the help of time correlated single photon counting module (SPCM, Becker&Hickl) which will give a novel dimension in quantitative biomedical imaging.

  7. Detection of beryllium treatment of natural sapphires by NRA

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, P.C., E-mail: carolina.gutierrez@uam.e [Centro de Micro-Analisis de Materiales (CMAM), Universidad Autonoma de Madrid, Campus de Cantoblanco, 28049 Madrid (Spain); Ynsa, M.-D.; Climent-Font, A. [Centro de Micro-Analisis de Materiales (CMAM), Universidad Autonoma de Madrid, Campus de Cantoblanco, 28049 Madrid (Spain); Dpto. Fisica Aplicada C-12, Universidad Autonoma de Madrid, Campus de Cantoblanco, 28049 Madrid (Spain); Calligaro, T. [Centre de Recherche et de Restauration des musees de France C2RMF, CNRS-UMR171, 14 quai Francois Mitterrand, 75001 Paris (France)

    2010-06-15

    Since the 1990's, artificial treatment of natural sapphires (Al{sub 2}O{sub 3} crystals coloured by impurities) by diffusion of beryllium at high temperature has become a growing practice. This process permits to enhance the colour of these gemstones, and thus to increase their value. Detection of such a treatment - diffusion of tens of {mu}g/g of beryllium in Al{sub 2}O{sub 3} crystals - is usually achieved using high sensitivity techniques like laser-ablation inductively coupled plasma mass spectrometry (LA-ICP/MS) or laser-induced breakdown spectrometry (LIBS) which are unfortunately micro-destructive (leaving 50-100-{mu}m diameter craters on the gems). The simple and non-destructive alternative method proposed in this work is based on the nuclear reaction {sup 9}Be({alpha}, n{gamma}){sup 12}C with an external helium ion beam impinging on the gem directly placed in air. The 4439 keV prompt {gamma}-ray tagging Be atoms are detected with a high efficiency bismuth germanate scintillator. Beam dose is monitored using the 2235 keV prompt {gamma}-ray produced during irradiation by the aluminium of the sapphire matrix through the {sup 27}Al({alpha}, p{gamma}){sup 30}Si nuclear reaction. The method is tested on a series of Be-treated sapphires previously analyzed by LA-ICP/MS to determine the optimal conditions to obtain a peak to background appropriate to reach the required {mu}g/g sensitivity. Using a 2.8-MeV external He beam and a beam dose of 200 {mu}C, beryllium concentrations from 5 to 16 {mu}g/g have been measured in the samples, with a detection limit of 1 {mu}g/g.

  8. Oxidation states of Fe and Ti in blue sapphire

    International Nuclear Information System (INIS)

    Wongrawang, P; Wongkokua, W; Monarumit, N; Thammajak, N; Wathanakul, P

    2016-01-01

    X-ray absorption near-edge spectroscopy (XANES) can be used to study the oxidation state of a dilute system such as transition metal defects in solid-state samples. In blue sapphire, Fe and Ti are defects that cause the blue color. Inter-valence charge transfer (IVCT) between Fe 2+ and Ti 4+ has been proposed to describe the optical color’s origin. However, the existence of divalent iron cations has not been thoroughly investigated. Fluorescent XANES is therefore employed to study K-edge absorptions of Fe and Ti cations in various blue sapphire samples including natural, synthetic, diffused and heat-treated sapphires. All the samples showed an Fe absorption edge at 7124 eV, corresponding to the Fe 3+ state; and Ti at 4984 eV, corresponding to Ti 4+ . From these results, we propose Fe 3+ -Ti 4+ mixed acceptor states located at 1.75 eV and 2.14 eV above the valence band of corundum, that correspond to 710 nm and 580 nm bands of UV–vis absorption spectra, to describe the cause of the color of blue sapphire. (paper)

  9. Review and perspective: Sapphire optical fiber cladding development for harsh environment sensing

    Science.gov (United States)

    Chen, Hui; Buric, Michael; Ohodnicki, Paul R.; Nakano, Jinichiro; Liu, Bo; Chorpening, Benjamin T.

    2018-03-01

    The potential to use single-crystal sapphire optical fiber as an alternative to silica optical fibers for sensing in high-temperature, high-pressure, and chemically aggressive harsh environments has been recognized for several decades. A key technological barrier to the widespread deployment of harsh environment sensors constructed with sapphire optical fibers has been the lack of an optical cladding that is durable under these conditions. However, researchers have not yet succeeded in incorporating a high-temperature cladding process into the typical fabrication process for single-crystal sapphire fibers, which generally involves seed-initiated fiber growth from the molten oxide state. While a number of advances in fabrication of a cladding after fiber-growth have been made over the last four decades, none have successfully transitioned to a commercial manufacturing process. This paper reviews the various strategies and techniques for fabricating an optically clad sapphire fiber which have been proposed and explored in published research. The limitations of current approaches and future prospects for sapphire fiber cladding are discussed, including fabrication methods and materials. The aim is to provide an understanding of the past research into optical cladding of sapphire fibers and to assess possible material systems for future research on this challenging problem for harsh environment sensors.

  10. Electronic structure analysis of GaN films grown on r- and a-plane sapphire

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, Monu; Krishna TC, Shibin; Aggarwal, Neha [Physics of Energy Harvesting Division, CSIR-National Physical Laboratory (CSIR-NPL), Dr. K.S. Krishnan Marg, New Delhi 110012 (India); Academy of Scientific and Innovative Research (AcSIR), CSIR-NPL Campus, Dr. K.S. Krishnan Marg, New Delhi 110012 (India); Vihari, Saket [Physics of Energy Harvesting Division, CSIR-National Physical Laboratory (CSIR-NPL), Dr. K.S. Krishnan Marg, New Delhi 110012 (India); Gupta, Govind, E-mail: govind@nplindia.org [Physics of Energy Harvesting Division, CSIR-National Physical Laboratory (CSIR-NPL), Dr. K.S. Krishnan Marg, New Delhi 110012 (India); Academy of Scientific and Innovative Research (AcSIR), CSIR-NPL Campus, Dr. K.S. Krishnan Marg, New Delhi 110012 (India)

    2015-10-05

    Graphical abstract: Substrate orientation induced changes in surface chemistry, band bending, hybridization states, electronic properties and surface morphology of epitaxially grown GaN were investigated via photoemission spectroscopic and Atomic Force Microscopic measurements. - Highlights: • Electronic structure and surface properties of GaN film grown on r/a-plane sapphire. • Downward band bending (0.5 eV) and high surface oxide is observed for GaN/a-sapphire. • Electron affinity and ionization energy is found to be higher for GaN/a-sapphire. - Abstract: The electronic structure and surface properties of epitaxial GaN films grown on r- and a-plane sapphire substrates were probed via spectroscopic and microscopic measurements. X-ray photoemission spectroscopic (XPS) measurements were performed to analyse the surface chemistry, band bending and valence band hybridization states. It was observed that GaN/a-sapphire display a downward band bending of 0.5 eV and possess higher amount of surface oxide compared to GaN/r-sapphire. The valence band (VB) investigation revealed that the hybridization corresponds to the interactions of Ga 4s and Ga 4p orbitals with N 2p orbital, and result in N2p–Ga4p, N2p–Ga4s{sup ∗}, mixed and N2p–Ga4s states. The energy band structure and electronic properties were measured via ultraviolet photoemission spectroscopic (UPS) experiments. The band structure analysis and electronic properties calculations divulged that the electron affinity and ionization energy of GaN/a-sapphire were 0.3 eV higher than GaN/r-sapphire film. Atomic Force Microscopic (AFM) measurements revealed faceted morphology of GaN/r-sapphire while a smooth pitted surface was observed for GaN/a-sapphire film, which is closely related to surface oxide coverage.

  11. High-rate sputter deposition of NiAl on sapphire fibers

    Energy Technology Data Exchange (ETDEWEB)

    Reichert, K.; Martinez, C.; Cremer, R.; Neuschuetz, D. [Lehrstuhl fuer Theoretische Huettenkunde, RWTH Aachen, Aachen (Germany)

    2002-07-01

    Once the fiber-matrix bonding has been optimized to meet the different requirements during fabrication and operation of the later composite component, sapphire fiber reinforced NiAl will be a potential candidate to substitute conventional superalloys as structural material for gas turbine blades. To improve the composite fabrication process, a direct deposition of the intermetallic matrix material onto hBN coated sapphire fibers prior to the consolidation of the fiber-matrix composite is proposed. It is believed that this will simplify the fabrication process and prevent pore formation during the diffusion bonding. In addition, the fiber volume fraction can be quite easily adjusted by varying the NiAl coating thickness. For this, a high-rate deposition of NiAl is in any case necessary. It has been achieved by a pulsed DC magnetron sputtering of combined Al-Ni targets with the fibers rotating between the two facing cathodes. The obtained nickel aluminide coatings were analyzed as to structure and composition by means of X-ray (GIXRD) as well as electron diffraction (RHEED) and X-ray photoelectron spectroscopy (XPS), respectively. The morphology of the NiAl coatings was examined by SEM. (orig.)

  12. Hematology

    International Nuclear Information System (INIS)

    Price, D.C.; Ries, C.

    1975-01-01

    This paper reviews the wide variety of radioisotopic techniques available to pediatricians in hematologic evaluation of their patients, with comments on the tracer techniques, and an indication of some new territory in splenic evaluation and nonradioactive tracers which may prove to be of considerable interest in the future. The only differences in applying these techniques to the pediatric population, compared with the adult population, lie in the different spectrum of hematologic diseases under consideration in this age group and the greater sensitivity to problems of radiation exposure which the pediatrician and the nuclear medicine physician must have in administering the isotopes in vivo. With these considerations in mind, the usefulness of such radioisotopic techniques in the evaluation of pediatric hematologic disease remains unquestionable. Radiopharmaceuticals and the radiation doses associated with the various procedures are listed. It is hoped in the future that fluorescent excitation techniques will replace at least s []me of the radioisotope techniques, obviating all considerations of patient irradiation in such instances. (auth)

  13. Use of sapphire as a neutron damage monitor for pressure vessel steels

    International Nuclear Information System (INIS)

    Pells, G.P.; Fudge, A.J.; Murphy, M.J.; Watt, S.

    1989-01-01

    Single crystal α-Al 2 O 3 (sapphire) has been neutron irradiated over a range of dose, dose rate and neutron energy spectra at temperatures from 60 to 310 0 C. Values of optical absorption at 400 nm, the peak of the aluminum vacancy absorption band, were plotted against damage dose expressed in terms of dpa of Al in sapphire obtained from measurements of induced radio-activity in activation foils irradiated with the sapphires and from calculation of the neutron energy spectrum at the irradiation position. The neutron energy spectrum was calculated using modern neutron transport computer codes and adjusted in the light of measurements obtained from multiple foil activation experiments. A simple response curve was obtained for all sapphires irradiated at temperatures between 220 to 310 0 C and for sapphires irradiated below 200 0 C which had been annealed at 290 0 C irrespective of dose rate or neutron beam energy spectrum. The single response curve for irradiations performed in a variety of neutron energy spectra validate the neutron energy spectrum computational procedures

  14. Neutron Transmission through Sapphire Crystals

    DEFF Research Database (Denmark)

    of simulations, in order to reproduce the transmission of cold neutrons through sapphire crystals. Those simulations were part of the effort of validating and improving the newly developed interface between the Monte-Carlo neutron transport code MCNP and the Monte Carlo ray-tracing code McStas....

  15. Investigation of the photoluminescence properties of Au/ZnO/sapphire and ZnO/Au/sapphire films by experimental study and electromagnetic simulation

    International Nuclear Information System (INIS)

    Zeng, Yong; Zhao, Yan; Jiang, Yijian

    2015-01-01

    Highlights: • Photoluminescent properties from Au/ZnO/sapphire and ZnO/Au/sapphire structures have been investigated. • The enhancement of UV intensity is a result of the enhanced electric field intensity of the 325 nm excitation light. • Electron transfer which induced by the local surface may be also account for the enhancement of UV emissions. • The suppression of the visible emissions might be due to the flowing of electrons in the defect states to the Au. - Abstract: Photoluminescent properties from Au/ZnO/sapphire and ZnO/Au/sapphire structures have been investigated. It is found that due to the co-interaction between the incident light and local surface plasmons, the ultraviolet (UV) emissions from the two structures were both enhanced and the visible emissions related to the defects were suppressed. By the means of electromagnetic simulation, it indicates that the enhancement of UV intensity is a result of the enhanced electric field intensity of the 325 nm excitation light, which is induced by localized surface plasmons resonance (LSPR). On the other hand, electron transfer which is induced by the local surface also account for the enhancement of UV emissions. The suppression of the visible emissions might be due to the flowing of electrons in the defect states to the Au, which caused the reduction of the electrons in the defect states

  16. High Temperature Testing with Sapphire Fiber White-Light Michelson Interferometers

    Science.gov (United States)

    Barnes, A.; Pedrazzani, J.; May, R.; Murphy, K.; Tran, T.; Coate, J.

    1996-01-01

    In the design of new aerospace materials, developmental testing is conducted to characterize the behavior of the material under severe environmental conditions of high stress, temperature, and vibration. But to test these materials under extreme conditions requires sensors that can perform in harsh environments. Current sensors can only monitor high temperature test samples using long throw instrumentation, but this is inherently less accurate than a surface mounted sensor, and provides no means for fabrication process monitoring. A promising alternative is the use of sapphire optical fiber sensors. Sapphire is an incredibly rugged material, being extremely hard (9 mhos), chemically inert, and having a melting temperature (over 2000 C). Additionally, there is a extensive background of optical fiber sensors upon which to draw for sapphire sensor configurations.

  17. 21 CFR 864.5680 - Automated heparin analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated heparin analyzer. 864.5680 Section 864.5680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...

  18. Thermal healing of the sub-surface damage layer in sapphire

    International Nuclear Information System (INIS)

    Pinkas, Malki; Lotem, Haim; Golan, Yuval; Einav, Yeheskel; Golan, Roxana; Chakotay, Elad; Haim, Avivit; Sinai, Ela; Vaknin, Moshe; Hershkovitz, Yasmin; Horowitz, Atara

    2010-01-01

    The sub-surface damage layer formed by mechanical polishing of sapphire is known to reduce the mechanical strength of the processed sapphire and to degrade the performance of sapphire based components. Thermal annealing is one of the methods to eliminate the sub-surface damage layer. This study focuses on the mechanism of thermal healing by studying its effect on surface topography of a- and c-plane surfaces, on the residual stresses in surface layers and on the thickness of the sub-surface damage layer. An atomically flat surface was developed on thermally annealed c-plane surfaces while a faceted roof-top topography was formed on a-plane surfaces. The annealing resulted in an improved crystallographic perfection close to the sample surface as was indicated by a noticeable decrease in X-ray rocking curve peak width. Etching experiments and surface roughness measurements using white light interferometry with sub-nanometer resolution on specimens annealed to different extents indicate that the sub-surface damage layer of the optically polished sapphire is less than 3 μm thick and it is totally healed after thermal treatment at 1450 deg. C for 72 h.

  19. Crystal orientation mechanism of ZnTe epilayers formed on different orientations of sapphire substrates by molecular beam epitaxy

    International Nuclear Information System (INIS)

    Nakasu, T.; Yamashita, S.; Aiba, T.; Hattori, S.; Sun, W.; Taguri, K.; Kazami, F.; Kobayashi, M.

    2014-01-01

    The electrooptic effect in ZnTe has recently attracted research attention, and various device structures using ZnTe have been explored. For application to practical terahertz wave detector devices based on ZnTe thin films, sapphire substrates are preferred because they enable the optical path alignment to be simplified. ZnTe/sapphire heterostructures were focused upon, and ZnTe epilayers were prepared on highly mismatched sapphire substrates by molecular beam epitaxy. Epitaxial relationships between the ZnTe thin films and the sapphire substrates with their various orientations were investigated using an X-ray diffraction pole figure method. (0001) c-plane, (1-102) r-plane, (1-100) m-plane, and (11-20) a-plane oriented sapphire substrates were used in this study. The epitaxial relationship between ZnTe and c-plane sapphire was found to be (111) ZnTe//(0001) sapphire with an in-plane orientation relationship of [−211] ZnTe//[1-100] sapphire. It was found that the (211)-plane ZnTe layer was grown on the m-plane of the sapphire substrates, and the (100)-plane ZnTe layer was grown on the r-plane sapphire. When the sapphire substrates were inclined from the c-plane towards the m-axis direction, the orientation of the ZnTe thin films was then tilted from the (111)-plane to the (211)-plane. The c-plane of the sapphire substrates governs the formation of the (111) ZnTe domain and the ZnTe epilayer orientation. These crystallographic features were also related to the atom arrangements of ZnTe and sapphire.

  20. Flashlamp pumped Ti-sapphire laser for ytterbium glass chirped pulse amplification

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Akihiko; Ohzu, Akira; Sugiyama, Akira [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; and others

    1998-03-01

    A flashlamp pumped Ti:sapphire laser is designed for ytterbium glass chirped pulse amplification. A high quality Ti:sapphire rod and a high energy long pulse discharging power supply are key components. The primary step is to produce the output power of 10 J per pulse at 920 nm. (author)

  1. The Importance of Hematological Parameters in Acute Respiratory Viral Infections in Children

    Directory of Open Access Journals (Sweden)

    L. A. Alekseeva

    2013-01-01

    Full Text Available Hematological studies are basic and mandatory in diagnostics and laboratory monitoring of infectious diseases, which led to their inclusion in the modern standards of laboratory examinations of children. Assessment of hematological parameters used for the provisional differential diagnosis of viral or bacterial nature of the disease. For research currently being used increasingly Hematology analyzers, which allows to facilitate and standardize the results. In this paper a comparison and differences hematological parameters practically healthy children and children with respiratory infections. Identified some changes in indicators of haemogram depending on the etiology and character of the clinical course of the disease. On the basis of the leukocyte formula defined leukocyte indices of intoxication and illustrates their importance in assessing the severity of the infection process.

  2. Sapphire-fiber-based distributed high-temperature sensing system.

    Science.gov (United States)

    Liu, Bo; Yu, Zhihao; Hill, Cary; Cheng, Yujie; Homa, Daniel; Pickrell, Gary; Wang, Anbo

    2016-09-15

    We present, for the first time to our knowledge, a sapphire-fiber-based distributed high-temperature sensing system based on a Raman distributed sensing technique. High peak power laser pulses at 532 nm were coupled into the sapphire fiber to generate the Raman signal. The returned Raman Stokes and anti-Stokes signals were measured in the time domain to determine the temperature distribution along the fiber. The sensor was demonstrated from room temperature up to 1200°C in which the average standard deviation is about 3.7°C and a spatial resolution of about 14 cm was achieved.

  3. MBE growth and characterization of ZnTe epilayers on m-plane sapphire substrates

    Energy Technology Data Exchange (ETDEWEB)

    Nakasu, Taizo; Sun, Wei-Che; Yamashita, Sotaro; Aiba, Takayuki; Taguri, Kosuke [Department of Electrical Engineering and Bioscience, Waseda University, Tokyo 169-8555 (Japan); Kobayashi, Masakazu [Department of Electrical Engineering and Bioscience, Waseda University, Tokyo 169-8555 (Japan); Kagami Memorial Research Institute for Materials Science and Technology, Waseda University, 2-8-26, Tokyo 169-0051 (Japan); Asahi, Toshiaki [Technology Development Center, JX Nippon Mining and Metals Corporation, Hitachi 317-0056 (Japan); Togo, Hiroyoshi [NTT Microsystem Integration Laboratories, Atsugi 243-0198 (Japan)

    2014-07-15

    ZnTe epilayers were grown on transparent (10-10) oriented (m -plane) sapphire substrates by molecular beam epitaxy (MBE). Pole figure imaging was used to study the domain distribution within the layer. (211)-oriented ZnTe domains were formed on m -plane sapphire. The presence of only one kind of (211) ZnTe domain formed on the 2 -tilted m -plane sapphire substrates was confirmed. Thus, single domain (211) ZnTe epilayers can be grown on the m -plane sapphire using MBE. Although differences in the crystal structure and lattice mismatch are large, precise control of the substrate surface lattice arrangement result in the formation of high-quality epitaxial layers. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  4. REPTILE HEMATOLOGY

    Directory of Open Access Journals (Sweden)

    Nejra Hadžimusić

    2013-03-01

    Full Text Available Determination of the number of circulating blood cells is of a great importance in clinical diagnosis. However, in some species, such as birds and reptiles, it is not possible to determine the number of individual blood cells using standard automated equipment, because of the specific morphological characteristics. For this reason, recognition of individual cell elements is crucial during hematological examination. Key words: Hematology, reptiles, blood cell morphology

  5. Structural characterization of AgGaTe{sub 2} layers grown on a- and c-sapphire substrates by a closed space sublimation method

    Energy Technology Data Exchange (ETDEWEB)

    Uruno, Aya; Usui, Ayaka [Department of Electrical Engineering and Bioscience, Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo 169-8555 (Japan); Kobayashi, Masakazu [Department of Electrical Engineering and Bioscience, Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo 169-8555 (Japan); Kagami Memorial Research Institute for Materials Science and Technology, Waseda University, 2-8-26 Nishiwaseda, Shinjuku, Tokyo 169-0051 (Japan)

    2014-07-15

    AgGaTe{sub 2} layers were grown on a- and c-plane sapphire substrates by a closed space sublimation method with varying the source temperature. Grown films were evaluated by θ -2θ and pole figure measurements of X-ray diffraction. AgGaTe{sub 2} layers were grown to have strong preference for the (103) orientation. However, it was cleared the Ag{sub 5}Te{sub 3} was formed along with the AgGaTe{sub 2} when the layer was grown on c-plane sapphire. The orientation of the film was analyzed by using the pole figure, and resulted in AgGaTe{sub 2} without Ag{sub 5}Te{sub 3} layers could be grown on a-plane sapphire. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  6. Structural and electronic characterization of graphene grown by chemical vapor deposition and transferred onto sapphire

    International Nuclear Information System (INIS)

    Joucken, Frédéric; Colomer, Jean-François; Sporken, Robert; Reckinger, Nicolas

    2016-01-01

    Highlights: • CVD graphene is transferred onto sapphire. • Transport measurements reveal relatively low charge carriers mobility. • Scanning probe microscopy experiments reveal the presence of robust contaminant layers between the graphene and the sapphire, responsible for the low carriers mobility. - Abstract: We present a combination of magnetotransport and local probe measurements on graphene grown by chemical vapor deposition on copper foil and subsequently transferred onto a sapphire substrate. A rather strong p-doping is observed (∼9 × 10 12 cm −2 ) together with quite low carrier mobility (∼1350 cm 2 /V s). Atomic force and tunneling imaging performed on the transport devices reveals the presence of contaminants between sapphire and graphene, explaining the limited performance of our devices. The transferred graphene displays ridges similar to those observed whilst graphene is still on the copper foil. We show that, on sapphire, these ridges are made of different thicknesses of the contamination layer and that, contrary to what was reported for hBN or certain transition metal dichalcogenides, no self-cleansing process of the sapphire substrate is observed.

  7. Microstructure evolution in carbon-ion implanted sapphire

    International Nuclear Information System (INIS)

    Orwa, J. O.; McCallum, J. C.; Jamieson, D. N.; Prawer, S.; Peng, J. L.; Rubanov, S.

    2010-01-01

    Carbon ions of MeV energy were implanted into sapphire to fluences of 1x10 17 or 2x10 17 cm -2 and thermally annealed in forming gas (4% H in Ar) for 1 h. Secondary ion mass spectroscopy results obtained from the lower dose implant showed retention of implanted carbon and accumulation of H near the end of range in the C implanted and annealed sample. Three distinct regions were identified by transmission electron microscopy of the implanted region in the higher dose implant. First, in the near surface region, was a low damage region (L 1 ) composed of crystalline sapphire and a high density of plateletlike defects. Underneath this was a thin, highly damaged and amorphized region (L 2 ) near the end of range in which a mixture of i-carbon and nanodiamond phases are present. Finally, there was a pristine, undamaged sapphire region (L 3 ) beyond the end of range. In the annealed sample some evidence of the presence of diamond nanoclusters was found deep within the implanted layer near the projected range of the C ions. These results are compared with our previous work on carbon implanted quartz in which nanodiamond phases were formed only a few tens of nanometers from the surface, a considerable distance from the projected range of the ions, suggesting that significant out diffusion of the implanted carbon had occurred.

  8. SERS Raman Sensor Based on Diameter-Modulated Sapphire Fiber

    Energy Technology Data Exchange (ETDEWEB)

    Shimoji, Yutaka

    2010-08-09

    Surface enhanced Raman scattering (SERS) has been observed using a sapphire fiber coated with gold nano-islands for the first time. The effect was found to be much weaker than what was observed with a similar fiber coated with silver nanoparticles. Diameter-modulated sapphire fibers have been successfully fabricated on a laser heated pedestal growth system. Such fibers have been found to give a modest increase in the collection efficiency of induced emission. However, the slow response of the SERS effect makes it unsuitable for process control applications.

  9. Towards rhombohedral SiGe epitaxy on 150mm c-plane sapphire substrates

    Science.gov (United States)

    Duzik, Adam J.; Park, Yeonjoon; Choi, Sang H.

    2015-04-01

    Previous work demonstrated for the first time the ability to epitaxially grow uniform single crystal diamond cubic SiGe (111) films on trigonal sapphire (0001) substrates. While SiGe (111) forms two possible crystallographic twins on sapphire (0001), films consisting primarily of one twin were produced on up to 99.95% of the total wafer area. This permits new bandgap engineering possibilities and improved group IV based devices that can exploit the higher carrier mobility in Ge compared to Si. Models are proposed on the epitaxy of such dissimilar crystal structures based on the energetic favorability of crystallographic twins and surface reconstructions. This new method permits Ge (111) on sapphire (0001) epitaxy, rendering Ge an economically feasible replacement for Si in some applications, including higher efficiency Si/Ge/Si quantum well solar cells. Epitaxial SiGe films on sapphire showed a 280% increase in electron mobility and a 500% increase in hole mobility over single crystal Si. Moreover, Ge possesses a wider bandgap for solar spectrum conversion than Si, while the transparent sapphire substrate permits an inverted device structure, increasing the total efficiency to an estimated 30-40%, much higher than traditional Si solar cells. Hall Effect mobility measurements of the Ge layer in the Si/Ge/Si quantum well structure were performed to demonstrate the advantage in carrier mobility over a pure Si solar cell. Another application comes in the use of microelectromechanical devices technology, where high-resistivity Si is currently used as a substrate. Sapphire is a more resistive substrate and offers better performance via lower parasitic capacitance and higher film carrier mobility over the current Si-based technology.

  10. Characterization of single crystal uranium-oxide thin films grown via reactive-gas magnetron sputtering on yttria-stabilized zirconia and sapphire

    Energy Technology Data Exchange (ETDEWEB)

    Strehle, Melissa M.; Heuser, Brent J., E-mail: bheuser@illinois.edu; Elbakhshwan, Mohamed S.; Han Xiaochun; Gennardo, David J.; Pappas, Harrison K.; Ju, Hyunsu

    2012-06-30

    The microstructure and valence states of three single crystal thin film systems, UO{sub 2} on (11{sup Macron }02) r-plane sapphire, UO{sub 2} on (001) yttria-stabilized zirconia, and U{sub 3}O{sub 8} on (11{sup Macron }02) r-plane sapphire, grown via reactive-gas magnetron sputtering are analyzed primarily with X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and ultraviolet photoelectron spectroscopy (UPS). XRD analysis indicates the growth of single crystal domains with varying degrees of mosaicity. XPS and UPS analyses yield U-4f, U-5f, O-1s, and O-2p electron binding energies consistent with reported bulk values. A change from p-type to n-type semiconductor behavior induced by preferential sputtering of oxygen during depth profile analysis was observed with both XPS and UPS. Trivalent cation impurities (Nd and Al) in UO{sub 2} lower the Fermi level, shifting the XPS spectral weight. This observation is consistent with hole-doping of a Mott-Hubbard insulator. The uranium oxide-(11{sup Macron }02) sapphire system is unstable with respect to Al interdiffusion across the film-substrate interface at elevated temperature. - Highlights: Black-Right-Pointing-Pointer Single crystal uranium-oxides grown on sapphire and yttria-stabilized zirconia. Black-Right-Pointing-Pointer Anion and cation valence states studied by photoelectron emission spectroscopy. Black-Right-Pointing-Pointer Trivalent Nd and Al impurities lower the Fermi level. Black-Right-Pointing-Pointer Uranium-oxide films on sapphire found to be unstable with respect to Al interdiffusion.

  11. Hematological findings in children with brucellosis.

    Science.gov (United States)

    Aypak, Adalet; Aypak, Cenk; Bayram, Yasemin

    2015-12-01

    Brucellosis produces a variety of non-specific hematological abnormalities. The aim of the present study was to evaluate the hematological findings in childhood brucellosis. Medical records of children with brucellosis admitted to a tertiary hospital in a 1 year period, were analyzed retrospectively. Sixty-nine patients (mean age, 14.5 ± 3.3 years) were diagnosed with brucellosis. The most common hematological finding was thrombocytopenia (n = 11, 15.9%). Thrombocytosis was detected in five patients (7.3%), leukopenia in four (5.8%), anemia in three (4.3%), and bicytopenia in three (4.3%). None of the patients had pancytopenia. Blood culture was positive for Brucella spp. in 41 patients (59.4%). Among those patients with positive blood culture, six (14.6%) had serum agglutination test titer ≤1/80. Platelet (PLT) count was significantly lower in the bacteremia-positive group. The OR (95%CI) of bacteremia for PLT cut-off 200,000/mm(3) was 0.148 (95%CI: 0.031-0.718) and relative risk was 1.718 (95%CI: 1.244-2.372; P = 0.010). Brucellosis should be kept in mind in the differential diagnosis of isolated thrombocytopenia in pediatric patients from endemic areas. © 2015 Japan Pediatric Society.

  12. The european hematology association roadmap for european hematology research : A consensus document

    NARCIS (Netherlands)

    A. Engert (Andreas); C.L. Balduini (Carlo); A. Brand (Anneke); B. Coiffier (Bertrand); C. Cordonnier (Charlotte); H. Döhner (Hartmut); De Wit, T.D. (Thom Duyvené); Eichinger, S. (Sabine); W.E. Fibbe (Willem); Green, T. (Tony); De Haas, F. (Fleur); A. Iolascon (Achille); T. Jaffredo (Thierry); F. Rodeghiero (Francesco); G. Salles (Gilles); J.J. Schuringa (Jan Jacob)

    2016-01-01

    textabstractThe European Hematology Association (EHA) Roadmap for European Hematology Research highlights major achievements in diagnosis and treatment of blood disorders and identifies the greatest unmet clinical and scientific needs in those areas to enable better funded, more focused European

  13. Hematological evaluation of splenomegaly

    International Nuclear Information System (INIS)

    Ali, N.; Anwar, M.; Ayyub, M.; Ejaz, A.; Nadeem, M.; Qureshi, A.H.; Qamar, M.A.

    2004-01-01

    Objective: To find out the relative frequency of clinical conditions associated with splenomegaly that require hematological evaluation in our set up. Subjects and Methods: Patients of either gender or all age groups with palpable spleen was included. Patients with splenomegaly due to liver disease, malarial parasites on thick or thin blood film, positive Widal test, or positive blood cultures were excluded from study. Patients were initially evaluated with clinical history, microscopic examination of blood smear, and blood counts. Depending upon provisional diagnosis bone marrow examination or investigations for hemolytic anemia were performed. Results: One hundred patients were received. Seventy-eight patients were adults and 22 patients were of pediatric age group. In the adults, hematological malignancies were seen in 37%, malarial parasites in bone marrow in 20.5%, megaloblastic anemia in 13%, bacterial infections in 9%, hemolytic anemia in 9%, tropical splenomegaly in 5%, and positive bone marrow culture for salmonella in 6.5%. In children, hematological evaluation revealed hematological malignancies in 18%, beta thalassaemia in 55%, other hemolytic anemias in 13.5%, congenital sideroblastic anemia in 4.5%, and storage disorder in 9%. Conclusion: Hematological workup is informative in most of the cases. Bone marrow examination is the key investigation, hematological malignancies constituted 37% of the adult and 18% of pediatric age group patients. Hemolytic anemia constituted 68% of pediatric age group. (author)

  14. Efficient continuous-wave and passively Q-switched pulse laser operations in a diffusion-bonded sapphire/Er:Yb:YAl3(BO3)4/sapphire composite crystal around 1.55 μm.

    Science.gov (United States)

    Chen, Yujin; Lin, Yanfu; Huang, Jianhua; Gong, Xinghong; Luo, Zundu; Huang, Yidong

    2018-01-08

    A composite crystal consisting of a 1.5-mm-thick Er:Yb:YAl 3 (BO 3 ) 4 crystal between two 1.2-mm-thick sapphire crystals was fabricated by the thermal diffusion bonding technique. Compared with a lone Er:Yb:YAl 3 (BO 3 ) 4 crystal measured under the identical experimental conditions, higher laser performances were demonstrated in the sapphire/Er:Yb:YAl 3 (BO 3 ) 4 /sapphire composite crystal due to the reduction of the thermal effects. End-pumped by a 976 nm laser diode in a hemispherical cavity, a 1.55 μm continuous-wave laser with a maximum output power of 1.75 W and a slope efficiency of 36% was obtained in the composite crystal when the incident pump power was 6.54 W. Passively Q-switched by a Co 2+ :MgAl 2 O 4 crystal, a 1.52 μm pulse laser with energy of 10 μJ and repetition frequency of 105 kHz was also realized in the composite crystal. Pulse width was 315 ns. The results show that the sapphire/Er:Yb:YAl 3 (BO 3 ) 4 /sapphire composite crystal is an excellent active element for 1.55 μm laser.

  15. Hematology reference intervals for neonatal Holstein calves.

    Science.gov (United States)

    Panousis, Nikolaos; Siachos, Nektarios; Kitkas, Georgios; Kalaitzakis, Emmanouil; Kritsepi-Konstantinou, Maria; Valergakis, Georgios E

    2018-01-09

    Data regarding hematologic reference intervals (RI) for neonatal calves have not been published yet. The aims of this study were: a) to establish hematology RIs for neonatal Holstein calves, b) to compare them with the RIs for lactating cows, and c) to investigate the relationship of age and gender with the hematologic profile of calves. Two-hundred and fifty-four clinically healthy Holstein calves (1-9days old, from 30 farms) and 82 healthy Holstein cows (between 30 and 150days in milk, from 10 farms) were blood sampled once for a complete blood count evaluation, using the ADVIA 120 hematology analyzer. An additional blood sample was collected from each calf for serum total protein concentration measurement. RIs and age-related RIs were calculated with the Reference Value Advisor freeware. Comparisons between calves and cows and between male and female calves were performed with t-test or Mann-Whitney test. Red blood cell count (RBC), white blood cell count (WBC), neutrophil, lymphocyte and platelet counts in calves were higher, while mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH) and mean corpuscular hemoglobin concentration (MCHC) were lower than in cows. Lymphocyte and platelets showed a notable increase through age. Finally, female calves had higher RBC, hematocrit and hemoglobin concentration than males. Age-specific RIs should be used for the interpretation of the complete blood count in Holstein calves. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Can dosimetric parameters predict acute hematologic toxicity in rectal cancer patients treated with intensity-modulated pelvic radiotherapy?

    International Nuclear Information System (INIS)

    Wan, Juefeng; Liu, Kaitai; Li, Kaixuan; Li, Guichao; Zhang, Zhen

    2015-01-01

    To identify dosimetric parameters associated with acute hematologic toxicity (HT) in rectal cancer patients undergoing concurrent chemotherapy and intensity-modulated pelvic radiotherapy. Ninety-three rectal cancer patients receiving concurrent capecitabine and pelvic intensity-modulated radiation therapy (IMRT) were analyzed. Pelvic bone marrow (PBM) was contoured for each patient and divided into three subsites: lumbosacral spine (LSS), ilium, and lower pelvis (LP). The volume of each site receiving 5–40 Gy (V 5, V10, V15, V20, V30, and V40, respectively) as well as patient baseline clinical characteristics was calculated. The endpoint for hematologic toxicity was grade ≥ 2 (HT2+) leukopenia, neutropenia, anemia or thrombocytopenia. Logistic regression was used to analyze correlation between dosimetric parameters and grade ≥ 2 hematologic toxicity. Twenty-four in ninety-three patients experienced grade ≥ 2 hematologic toxicity. Only the dosimetric parameter V40 of lumbosacral spine was correlated with grade ≥ 2 hematologic toxicity. Increased pelvic lumbosacral spine V40 (LSS-V40) was associated with an increased grade ≥ 2 hematologic toxicity (p = 0.041). Patients with LSS-V40 ≥ 60 % had higher rates of grade ≥ 2 hematologic toxicity than did patients with lumbosacral spine V40 < 60 % (38.3 %, 18/47 vs.13 %, 6/46, p =0.005). On univariate and multivariate logistic regression analysis, lumbosacral spine V40 and gender was also the variable associated with grade ≥ 2 hematologic toxicity. Female patients were observed more likely to have grade ≥ 2 hematologic toxicity than male ones (46.9 %, 15/32 vs 14.8 %, 9/61, p =0.001). Lumbosacral spine -V40 was associated with clinically significant grade ≥ 2 hematologic toxicity. Keeping the lumbosacral spine -V40 < 60 % was associated with a 13 % risk of grade ≥ 2 hematologic toxicity in rectal cancer patients undergoing concurrent chemoradiotherapy

  17. (211) oriented ZnTe growth on m-plane sapphire by MBE

    Energy Technology Data Exchange (ETDEWEB)

    Nakasu, Taizo [Department of Electrical Engineering and Bioscience, Waseda University, Tokyo 169-8555 (Japan); Kobayashi, Masakazu [Department of Electrical Engineering and Bioscience, Waseda University, Tokyo 169-8555 (Japan); Kagami Memorial Research Institute for Materials Science and Technology, Waseda University, 2-8-26, Tokyo 169-0051 (Japan); Togo, Hiroyoshi [NTT Microsystem Integration Laboratories, Atugi-shi 243-0198 (Japan); Asahi, Toshiaki [Technology Development Center, JX Nippon Mining and Metals Corporation, Hitachi-shi 317-0056 (Japan)

    2013-11-15

    Single-crystalline and single domain ZnTe thin films are sought for high-performance terahertz wave detectors, and ZnTe/sapphire heterostructures were considered since the Electro-Optical (EO) effect could be obtained only from epilayers. ZnTe epilayers were grown on m-plane sapphire substrates by molecular beam epitaxy, and the potential of single domain epilayers was explored. Through the X-ray diffraction pole figure measurement it was confirmed that one (100) oriented ZnTe domain along with two kinds of (211) oriented domains were formed on the m-plane sapphire when the layer was grown at 340 C. When the layer was grown at 350 C, the (211) oriented domain dominated the film. (copyright 2013 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  18. Sea level characterization of a 1100 g sapphire bolometer

    CERN Document Server

    Pécourt, S; Bobin, C; Coron, N; Jesus, M D; Hadjout, J P; Leblanc, J W; Marcillac, P D

    1999-01-01

    A first characterization of a 1100 g sapphire bolometer, performed at sea level and at a working temperature of 40 mK, is presented. Despite perturbations coming from the high-radioactive background and cosmic rays, calibration spectra could be achieved with an internal alpha source and a sup 5 sup 7 Co gamma-ray source: the experimental threshold is 25 keV, while the FWHM resolution is 17.4 keV for the 122 keV peak. Possible heat release effects are discussed, and a new limit of 9x10 sup - sup 1 sup 4 W/g is obtained for sapphire.

  19. Noise measurements on NbN thin films with a negative temperature resistance coefficient deposited on sapphire and on SiO2

    NARCIS (Netherlands)

    Leroy, G.; Gest, J.; Vandamme, L.K.J.; Bourgeois, O.

    2007-01-01

    We characterize granular NbNx thin cermet films deposited on either sapphire substrate or on SiO2 and compare the 1/f noise at 300 K and 80 K. The films were characterized with an impedance analyzer from 20 Hz to 1 MHz and analyzed as a resistor R in parallel with a capacitor C. The calculated noise

  20. Sapphire scintillation tests for cryogenic detectors in the Edelweiss dark matter search

    Energy Technology Data Exchange (ETDEWEB)

    Luca, M

    2007-07-15

    Identifying the matter in the universe is one of the main challenges of modern cosmology and astrophysics. An important part of this matter seems to be made of non-baryonic particles. Edelweiss is a direct dark matter search using cryogenic germanium bolometers in order to look for particles that interact very weakly with the ordinary matter, generically known as WIMPs (weakly interacting massive particles). An important challenge for Edelweiss is the radioactive background and one of the ways to identify it is to use a larger variety of target crystals. Sapphire is a light target which can be complementary to the germanium crystals already in use. Spectroscopic characterization studies have been performed using different sapphire samples in order to find the optimum doping concentration for good low temperature scintillation. Ti doped crystals with weak Ti concentrations have been used for systematic X ray excitation tests both at room temperature and down to 30 K. The tests have shown that the best Ti concentration for optimum room temperature scintillation is 100 ppm and 50 ppm at T = 45 K. All concentrations have been checked by optical absorption and fluorescence. After having shown that sapphire had interesting characteristics for building heat-scintillation detectors, we have tested if using a sapphire detector was feasible within a dark matter search. During the first commissioning tests of Edelweiss-II, we have proved the compatibility between a sapphire heat scintillation detector and the experimental setup. (author)

  1. Fe-N{sub x}/C assisted chemical–mechanical polishing for improving the removal rate of sapphire

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Li, E-mail: xl0522@126.com [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Shenzhen Key Laboratory of Micro/Nano Manufacturing, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); Zou, Chunli; Shi, Xiaolei [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Shenzhen Key Laboratory of Micro/Nano Manufacturing, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); Pan, Guoshun, E-mail: pangs@tsinghua.edu.cn [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Shenzhen Key Laboratory of Micro/Nano Manufacturing, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); Luo, Guihai; Zhou, Yan [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Shenzhen Key Laboratory of Micro/Nano Manufacturing, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China)

    2015-07-15

    Highlights: • A novel non-noble metal catalyst (Fe-N{sub x}/C) was prepared. • Fe-N{sub x}/C shows remarkable catalytic activity for improving the removal rate of sapphire in alkaline solution. • The optimum CMP removal by Fe-N{sub x}/C yielded a superior surface finish of 0.078 nm the average roughness. • Fe{sub 2}O{sub 3}, Fe{sub 3}O{sub 4}, pyridinic N as well as pyrrolic N group possibly serving as the catalytic sites. • A soft hydration layer (boehmite, AlO(OH)) was generated on the surface of sapphire during CMP process. - Abstract: In this paper, a novel non-noble metal catalyst (Fe-N{sub x}/C) is used to improve the removal mass of sapphire as well as obtain atomically smooth sapphire wafer surfaces. The results indicate that Fe-N{sub x}/C shows good catalytic activity towards sapphire removal rate. And the material removal rates (MRRs) are found to vary with the catalyst content in the polishing fluid. Especially that when the polishing slurry mixes with 16 ppm Fe-N{sub x}/C shows the maximum MRR and its removal mass of sapphire is 38.43 nm/min, more than 15.44% larger than traditional CMP using the colloidal silicon dioxide (SiO{sub 2}) without Fe-N{sub x}/C. Catalyst-assisted chemical–mechanical polishing of sapphire is studied with X-ray photoelectron spectroscopy (XPS). It is found that the formation of a soft hydration layer (boehmite, γ-AlOOH or γ-AlO(OH)) on sapphire surface facilitates the material removal and achieving fine surface finish on basal plane. Abrasives (colloid silica together with magnetite, ingredient of Fe-N{sub x}/C) with a hardness between boehmite and sapphire polish the c-plane of sapphire with good surface finish and efficient removal. Fe{sub 2}O{sub 3}, Fe{sub 3}O{sub 4}, pyridinic N as well as pyrrolic N group would be the catalytical active sites and accelerate this process. Surface quality is characterized with atomic force microscopy (AFM). The optimum CMP removal by Fe-N{sub x}/C also yields a superior

  2. The role of cytokines in development of hematological and immune disorders at radiation therapy for uterine body cancer

    International Nuclear Information System (INIS)

    Sorochan, P.P.; Prokhach, N.E.; Gromakova, Yi.A.; Krugova, Yi.M.; Sukhyin, V.S.

    2013-01-01

    The changes in hematological and immune parameters in patients with uterine body cancer were analyzed by the stages of the combined treatment. The rol of cytokines in the development of hematologic and immune disorders was assessed

  3. Nanoscratch Characterization of GaN Epilayers on c- and a-Axis Sapphire Substrates

    Directory of Open Access Journals (Sweden)

    Wen Hua-Chiang

    2010-01-01

    Full Text Available Abstract In this study, we used metal organic chemical vapor deposition to form gallium nitride (GaN epilayers on c- and a-axis sapphire substrates and then used the nanoscratch technique and atomic force microscopy (AFM to determine the nanotribological behavior and deformation characteristics of the GaN epilayers, respectively. The AFM morphological studies revealed that pile-up phenomena occurred on both sides of the scratches formed on the GaN epilayers. It is suggested that cracking dominates in the case of GaN epilayers while ploughing during the process of scratching; the appearances of the scratched surfaces were significantly different for the GaN epilayers on the c- and a-axis sapphire substrates. In addition, compared to the c-axis substrate, we obtained higher values of the coefficient of friction (μ and deeper penetration of the scratches on the GaN a-axis sapphire sample when we set the ramped force at 4,000 μN. This discrepancy suggests that GaN epilayers grown on c-axis sapphire have higher shear resistances than those formed on a-axis sapphire. The occurrence of pile-up events indicates that the generation and motion of individual dislocation, which we measured under the sites of critical brittle transitions of the scratch track, resulted in ductile and/or brittle properties as a result of the deformed and strain-hardened lattice structure.

  4. 42 CFR 493.1215 - Condition: Hematology.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Hematology. 493.1215 Section 493.1215 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES....1215 Condition: Hematology. If the laboratory provides services in the specialty of Hematology, the...

  5. 42 CFR 493.849 - Condition: Hematology.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Hematology. 493.849 Section 493.849 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... These Tests § 493.849 Condition: Hematology. The specialty of hematology, for the purpose of proficiency...

  6. Thermal neutron scattering kernels for sapphire and silicon single crystals

    International Nuclear Information System (INIS)

    Cantargi, F.; Granada, J.R.; Mayer, R.E.

    2015-01-01

    Highlights: • Thermal cross section libraries for sapphire and silicon single crystals were generated. • Debye model was used to represent the vibrational frequency spectra to feed the NJOY code. • Sapphire total cross section was measured at Centro Atómico Bariloche. • Cross section libraries were validated with experimental data available. - Abstract: Sapphire and silicon are materials usually employed as filters in facilities with thermal neutron beams. Due to the lack of the corresponding thermal cross section libraries for those materials, necessary in calculations performed in order to optimize beams for specific applications, here we present the generation of new thermal neutron scattering kernels for those materials. The Debye model was used in both cases to represent the vibrational frequency spectra required to feed the NJOY nuclear data processing system in order to produce the corresponding libraries in ENDF and ACE format. These libraries were validated with available experimental data, some from the literature and others obtained at the pulsed neutron source at Centro Atómico Bariloche

  7. Growth of cubic InN on r-plane sapphire

    International Nuclear Information System (INIS)

    Cimalla, V.; Pezoldt, J.; Ecke, G.; Kosiba, R.; Ambacher, O.; Spiess, L.; Teichert, G.; Lu, H.; Schaff, W.J.

    2003-01-01

    InN has been grown directly on r-plane sapphire substrates by plasma-enhanced molecular-beam epitaxy. X-ray diffraction investigations have shown that the InN layers consist of a predominant zinc blende (cubic) structure along with a fraction of the wurtzite (hexagonal) phase which content increases with proceeding growth. The lattice constant for zinc blende InN was found to be a=4.986 A. For this unusual growth of a metastable cubic phase on a noncubic substrate an epitaxial relationship was proposed where the metastable zinc blende phase grows directly on the r-plane sapphire while the wurtzite phase arises as the special case of twinning in the cubic structure

  8. An injection modelocked Ti-sapphire laser for synchronous photoinjection

    International Nuclear Information System (INIS)

    Hovater, C.; Poelker, M.

    1997-01-01

    The CEBAF 4 GeV accelerator has recently begun delivering spin-polarized electrons for nuclear physics experiments. Spin-polarized electrons are emitted from a GaAs photocathode that is illuminated with pulsed laser light from a diode laser system synchronized to the injector chopping frequency (499 MHz). The present diode laser system is compact, reliable and relatively maintenance-free; however, output power is limited to less than 500 mW. In an effort to obtain higher average power and thereby prolong the effective operating lifetime of the source, they have constructed an injection modelocked Ti-sapphire laser with picosecond pulsewidths and gigahertz repetition rates. Modelocked operation is obtained through gain modulation within the Ti-sapphire crystal as a result of injection seeding with a gain-switched diode laser. Unlike conventional modelocked lasers, the pulse repetition rate of this laser can be discretely varied by setting the seed laser repetition rate equal to multiples of the Ti-sapphire laser cavity fundamental frequency. They observe pulse repetition rates from 223 MHz (fundamental) to 1,560 MHz (seventh harmonic) with average output power of 700 mW for all repetition rates. Pulsewidths ranged from 21 to 39 ps (FWHM) under various pump laser conditions

  9. Reptile Hematology.

    Science.gov (United States)

    Sykes, John M; Klaphake, Eric

    2015-09-01

    The basic principles of hematology used in mammalian medicine can be applied to reptiles. The appearances of the blood cells are significantly different from those seen in most mammals, and vary with taxa and staining method used. Many causes for abnormalities of the reptilian hemogram are similar to those for mammals, although additional factors such as venipuncture site, season, hibernation status, captivity status, and environmental factors can also affect values, making interpretation of hematologic results challenging. Values in an individual should be compared with reference ranges specific to that species, gender, and environmental conditions when available. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Multiphoton imaging with a novel compact diode-pumped Ti:sapphire oscillator

    DEFF Research Database (Denmark)

    König, Karsten; Andersen, Peter E.; Le, Tuan

    2015-01-01

    Multiphoton laser scanning microscopy commonly relies on bulky and expensive femtosecond lasers. We integrated a novel minimal-footprint Ti:sapphire oscillator, pumped by a frequency-doubled distributed Bragg reflector tapered diode laser, into a clinical multiphoton tomograph and evaluated its...... imaging capability using different biological samples, i.e. cell monolayers, corneal tissue, and human skin. With the novel laser, the realization of very compact Ti:sapphire-based systems for high-quality multiphoton imaging at a significantly size and weight compared to current systems will become...

  11. X-ray characterization of CdO thin films grown on a-, c-, r- and m-plane sapphire by metalorganic vapour phase-epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Zuniga-Perez, J.; Martinez-Tomas, C.; Munoz-Sanjose, V. [Departamento de Fisica Aplicada y Electromagnetismo, Universitat de Valencia, C/Dr. Moliner 50, 46100 Burjassot (Spain)

    2005-02-01

    CdO thin films have been grown on a-plane (11 anti 20), c-plane (0001), r-plane (01 anti 12) and m-plane (10 anti 10) sapphire substrates by metalorganic vapour-phase epitaxy (MOVPE). The effects of different substrate orientations on the structural properties of the films have been analyzed by means of X-ray diffraction, including {theta}-2{theta} scans, pole figures and rocking curves. (111), (001) and (110) orientations are found on a-, r-, and m-sapphire respectively, while films deposited on c-plane exhibit an orientation in which no low-index crystal plane is parallel to the sample surface. The recorded pole figures have allowed determining the epitaxial relationships between films and substrates, as well as the presence or absence of extended defects. The rocking curves indicate that high quality thin films, in terms of tilt and twist, can be obtained on r-, c- and m-plane sapphire, while further improvement is needed over the a-orientation. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  12. X-ray characterization of CdO thin films grown on a-, c-, r- and m-plane sapphire by metalorganic vapour phase-epitaxy

    International Nuclear Information System (INIS)

    Zuniga-Perez, J.; Martinez-Tomas, C.; Munoz-Sanjose, V.

    2005-01-01

    CdO thin films have been grown on a-plane (11 anti 20), c-plane (0001), r-plane (01 anti 12) and m-plane (10 anti 10) sapphire substrates by metalorganic vapour-phase epitaxy (MOVPE). The effects of different substrate orientations on the structural properties of the films have been analyzed by means of X-ray diffraction, including θ-2θ scans, pole figures and rocking curves. (111), (001) and (110) orientations are found on a-, r-, and m-sapphire respectively, while films deposited on c-plane exhibit an orientation in which no low-index crystal plane is parallel to the sample surface. The recorded pole figures have allowed determining the epitaxial relationships between films and substrates, as well as the presence or absence of extended defects. The rocking curves indicate that high quality thin films, in terms of tilt and twist, can be obtained on r-, c- and m-plane sapphire, while further improvement is needed over the a-orientation. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  13. Theoretical studies on lattice-oriented growth of single-walled carbon nanotubes on sapphire

    Science.gov (United States)

    Li, Zhengwei; Meng, Xianhong; Xiao, Jianliang

    2017-09-01

    Due to their excellent mechanical and electrical properties, single-walled carbon nanotubes (SWNTs) can find broad applications in many areas, such as field-effect transistors, logic circuits, sensors and flexible electronics. High-density, horizontally aligned arrays of SWNTs are essential for high performance electronics. Many experimental studies have demonstrated that chemical vapor deposition growth of nanotubes on crystalline substrates such as sapphire offers a promising route to achieve such dense, perfectly aligned arrays. In this work, a theoretical study is performed to quantitatively understand the van der Waals interactions between SWNTs and sapphire substrates. The energetically preferred alignment directions of SWNTs on A-, R- and M-planes and the random alignment on the C-plane predicted by this study are all in good agreement with experiments. It is also shown that smaller SWNTs have better alignment than larger SWNTs due to their stronger interaction with sapphire substrate. The strong vdW interactions along preferred alignment directions can be intuitively explained by the nanoscale ‘grooves’ formed by atomic lattice structures on the surface of sapphire. This study provides important insights to the controlled growth of nanotubes and potentially other nanomaterials.

  14. Influence of TMAl preflow on AlN epitaxy on sapphire

    KAUST Repository

    Sun, Haiding; Wu, Feng; Park, Young Jae; Al tahtamouni, T. M.; Li, Kuang-Hui; Alfaraj, Nasir; Detchprohm, Theeradetch; Dupuis, Russell D.; Li, Xiaohang

    2017-01-01

    The trimethylaluminum (TMAl) preflow process has been widely applied on sapphire substrates prior to growing Al-polar AlN films by metalorganic chemical vapor deposition. However, it has been unclear how the TMAl preflow process really works. In this letter, we reported on carbon's significance in the polarity and growth mode of AlN films due to the TMAl preflow. Without the preflow, no trace of carbon was found at the AlN/sapphire interface and the films possessed mixed Al- and N-polarity. With the 5 s preflow, carbon started to precipitate due to the decomposition of TMAl, forming scattered carbon-rich clusters which were graphitic carbon. It was discovered that the carbon attracted surrounding oxygen impurity atoms and consequently suppressed the formation of AlxOyNz and thus N-polarity. With the 40 s preflow, the significant presence of carbon clusters at the AlN/sapphire interface was observed. While still attracting oxygen and preventing the N-polarity, the carbon clusters served as randomly distributed masks to further induce a 3D growth mode for the AlN growth. The corresponding epitaxial growth mode change is discussed.

  15. Influence of TMAl preflow on AlN epitaxy on sapphire

    KAUST Repository

    Sun, Haiding

    2017-05-12

    The trimethylaluminum (TMAl) preflow process has been widely applied on sapphire substrates prior to growing Al-polar AlN films by metalorganic chemical vapor deposition. However, it has been unclear how the TMAl preflow process really works. In this letter, we reported on carbon\\'s significance in the polarity and growth mode of AlN films due to the TMAl preflow. Without the preflow, no trace of carbon was found at the AlN/sapphire interface and the films possessed mixed Al- and N-polarity. With the 5 s preflow, carbon started to precipitate due to the decomposition of TMAl, forming scattered carbon-rich clusters which were graphitic carbon. It was discovered that the carbon attracted surrounding oxygen impurity atoms and consequently suppressed the formation of AlxOyNz and thus N-polarity. With the 40 s preflow, the significant presence of carbon clusters at the AlN/sapphire interface was observed. While still attracting oxygen and preventing the N-polarity, the carbon clusters served as randomly distributed masks to further induce a 3D growth mode for the AlN growth. The corresponding epitaxial growth mode change is discussed.

  16. 21 CFR 864.8625 - Hematology quality control mixture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8625 Hematology...

  17. Hematological dosimetry

    International Nuclear Information System (INIS)

    Fluery-Herard, A.

    1991-01-01

    The principles of hematological dosimetry after acute or protracted whole-body irradiation are reviewed. In both cases, over-exposure is never homogeneous and the clinical consequences, viz medullary aplasia, are directly associated with the mean absorbed dose and the seriousness and location of the overexposure. The main hematological data required to assess the seriousness of exposure are the following: repeated blood analysis, blood precursor cultures, as indicators of whole-body exposure; bone marrow puncture, medullary precursor cultures and medullary scintigraphy as indicators of the importance of a local over-exposure and capacity for spontaneous repair. These paraclinical investigations, which are essential for diagnosis and dosimetry, are also used for surveillance and for the main therapeutic issues [fr

  18. [Oral nutritional supplementation in hematologic patients].

    Science.gov (United States)

    Peñalva, A; San Martín, A; Rosselló, J; Pérez-Portabella, C; Palacios, A; Julià, A; Planas, M

    2009-01-01

    Hematological patients often present anorexia which along with other secondary effects from the chemotherapy and/or radiotherapy treatments compromise their nutritional status. Oral supplementation can aid to fulfill the energy and protein requirements of these patients. Nevertheless, the use of commercial nutritional supplements normally available, is limited by its poor intake. To evaluate the degree of fulfillment of the prescribed supplements and fulfillment of energy requirements, as well as the development of nutritional status in hematological patients hospitalized for treatment with chemotherapy and/or radiotherapy. Prospective, randomized and open study of inpatients at the hematological ward. Patients were randomized sequentially and they were assigned into 3 different nutritional interventions providing: Group 1 (G1), a flavored supplement; Group 2 (G2): a non flavored (neutral) supplement and Group 3 (G3): "kitchen" foods as supplements. Need and amount of nutritional supplements were provided according to the oral intake previously analyzed. Nutritional assessment (at admission and discharge) was based in the Subjective Global Assessment test (SGA), Risk Nutritional Index (RNI) and percentage of lost weight. Both fulfillment of supplement intake and achievement of energetic requirements were analyzed. 125 patients of 51.3 +/- 16.8 years; 45% men and 55% women. 54% lymphoma, 33% leukemia, 8% myeloma and others 4%. Length of stay (LOS): 7.0 +/- 3.6 d. The nutritional assessment done by SGA showed significant negative changes in G2 and G3 (G1: 30% developed malnutrition and 28% improved their nutritional status, p = NS; G2: 50% developed malnutrition against 7% whom improved their nutritional status, p = 0.002; y G3: 37% developed malnutrition against 21% whom improved their nutritional status, p = 0.02). According to RNI, patients evolved negatively from their nutritional state but no significant differences were found within groups (G1, from 81% of

  19. Centrifugal analyzer development

    International Nuclear Information System (INIS)

    Burtis, C.A.; Bauer, M.L.; Bostick, W.D.

    1976-01-01

    The development of the centrifuge fast analyzer (CFA) is reviewed. The development of a miniature CFA with computer data analysis is reported and applications for automated diagnostic chemical and hematological assays are discussed. A portable CFA system with microprocessor was adapted for field assays of air and water samples for environmental pollutants, including ammonia, nitrates, nitrites, phosphates, sulfates, and silica. 83 references

  20. American Society of Pediatric Hematology/Oncology

    Science.gov (United States)

    ... Learn More Explore career opportunities in pediatric hematology/oncology Visit the ASPHO Career Center. Learn More Join ... Privacy Policy » © The American Society of Pediatric Hematology/Oncology

  1. Testing of Sapphire Optical Fiber and Sensors in Intense Radiation Fields When Subjected to Very High Temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Blue, Thomas [The Ohio State Univ., Columbus, OH (United States); Windl, Wolfgang [The Ohio State Univ., Columbus, OH (United States)

    2017-12-15

    The primary objective of this project was to determine the optical attenuation and signal degradation of sapphire optical fibers & sensors (temperature & strain), in-situ, operating at temperatures up to 1500°C during reactor irradiation through experiments and modeling. The results will determine the feasibility of extending sapphire optical fiber-based instrumentation to extremely high temperature radiation environments. This research will pave the way for future testing of sapphire optical fibers and fiber-based sensors under conditions expected in advanced high temperature reactors.

  2. Transmission Electron Microscopy (TEM) Sample Preparation of Si(1-x)Gex in c-Plane Sapphire Substrate

    Science.gov (United States)

    Kim, Hyun Jung; Choi, Sang H.; Bae, Hyung-Bin; Lee, Tae Woo

    2012-01-01

    The National Aeronautics and Space Administration-invented X-ray diffraction (XRD) methods, including the total defect density measurement method and the spatial wafer mapping method, have confirmed super hetero epitaxy growth for rhombohedral single crystalline silicon germanium (Si1-xGex) on a c-plane sapphire substrate. However, the XRD method cannot observe the surface morphology or roughness because of the method s limited resolution. Therefore the authors used transmission electron microscopy (TEM) with samples prepared in two ways, the focused ion beam (FIB) method and the tripod method to study the structure between Si1-xGex and sapphire substrate and Si1?xGex itself. The sample preparation for TEM should be as fast as possible so that the sample should contain few or no artifacts induced by the preparation. The standard sample preparation method of mechanical polishing often requires a relatively long ion milling time (several hours), which increases the probability of inducing defects into the sample. The TEM sampling of the Si1-xGex on sapphire is also difficult because of the sapphire s high hardness and mechanical instability. The FIB method and the tripod method eliminate both problems when performing a cross-section TEM sampling of Si1-xGex on c-plane sapphire, which shows the surface morphology, the interface between film and substrate, and the crystal structure of the film. This paper explains the FIB sampling method and the tripod sampling method, and why sampling Si1-xGex, on a sapphire substrate with TEM, is necessary.

  3. Characteristics of a Ti:sapphire laser pumped by a Nd:YAG laser and its analysis. Nd:YAG laser reiki Ti:sapphire laser no dosa tokusei to sono kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Okada, T.; Masumoto, J.; Mizunami, T.; Maeda, M.; Muraoka, K. (Kyushu Univ., Fukuoka (Japan). Faculty of Engineering)

    1991-06-29

    Although Ti: Sapphire expects of a possibility of being a light source much superior to a dye laser having been used as a wavelength variable laser for spectral analyses, it has a limitation that it does not oscillate directly in the visible and ultraviolet regions. In order to develop a light source that is synchronizable over ultraviolet-near infrared regions, by means of combining a Ti: Sapphire laser of a high peak power, comprising an oscillator and a multistage amplifier, with a non-linear frequency conversion method for harmonic generation and Raman conversion, a prototype Ti:Sapphire laser that is excited by YAG laser second harmonic, and that synchronizes with a prism was fabricated, and its operational characteristics were investigated. As a result, an output energy of 35.6 mJ at a maximum was obtained at a wavelength of 773 nm against an excitation energy of 129 mJ, a conversion efficiency of 38.2% was obtained against the absorption energy of the crystals, and a continuous synchronism was achieved over 750 to 900 nm. 4 refs., 9 figs., 1 tab.

  4. Comparison of stress states in GaN films grown on different substrates: Langasite, sapphire and silicon

    Science.gov (United States)

    Park, Byung-Guon; Saravana Kumar, R.; Moon, Mee-Lim; Kim, Moon-Deock; Kang, Tae-Won; Yang, Woo-Chul; Kim, Song-Gang

    2015-09-01

    We demonstrate the evolution of GaN films on novel langasite (LGS) substrate by plasma-assisted molecular beam epitaxy, and assessed the quality of grown GaN film by comparing the experimental results obtained using LGS, sapphire and silicon (Si) substrates. To study the substrate effect, X-ray diffraction (XRD), scanning electron microscopy (SEM), Raman spectroscopy and photoluminescence (PL) spectra were used to characterize the microstructure and stress states in GaN films. Wet etching of GaN films in KOH solution revealed that the films deposited on GaN/LGS, AlN/sapphire and AlN/Si substrates possess Ga-polarity, while the film deposited on GaN/sapphire possess N-polarity. XRD, Raman and PL analysis demonstrated that a compressive stress exist in the films grown on GaN/LGS, AlN/sapphire, and GaN/sapphire substrates, while a tensile stress appears on AlN/Si substrate. Comparative analysis showed the growth of nearly stress-free GaN films on LGS substrate due to the very small lattice mismatch ( 3.2%) and thermal expansion coefficient difference ( 7.5%). The results presented here will hopefully provide a new framework for the further development of high performance III-nitride-related devices using GaN/LGS heteroepitaxy.

  5. Main hematological parameters of sturgeon species (Acipenseridae (review

    Directory of Open Access Journals (Sweden)

    M. Simon

    2017-03-01

    Full Text Available Purpose. To analyze scientific sources on the physiological, biochemical, ecological and genetic features of the main hematological paremeters and patterns of their variability in sturgeon species (Acipenseridae. To examine the fundamental aspects of lipid and protein metabolism in blood serum and the effect of biotic and abiotic factors on them. To highlight the common features of serum enzymes. Findings. A review of scientific papers revealed that although hematological parameters of sturgeons are generally similar to those of teleosts and mammals, there are a number of significant differences. In addition, many hematological parameters are characterized by species specificity, even within a family. Special attention is given to the variability of hematological parameters under the effect of factors of both internal and external environment. The paper describes the effects of sex and age, as well as the seasons of the year on the compositio of sturgeon blood. The fundamentals of the use of serum proteins in genetic and population studies are outlined. The features of the functioning of hemoglobin in sturgeon’s red blood cells are examined. The main hematological parameters involved in the formation and maturation of sexual products, and their effect on fertility are reviewed. For example, the spawners, which hadn’t put reproductive product, are characterized by a low rate of hemoglobin, increase in erythrocyte sedimentation speed and also a rise of the level of crude protein in blood and β-lipoproteid serum.The biochemical parameters (total protein and fractions, glucose, creatinine, cholesterol, the activity of some enzymes (alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase, creatine kinase in serum are examined. Practical value. The systematized data on the main hematological parameters and patterns of their variability in sturgeon species will be useful for both scientits and fish farmers. This is due to the

  6. Contribution to the microwave characterisation of superconductive materials by means of sapphire resonators

    International Nuclear Information System (INIS)

    Hanus, Xavier

    1993-01-01

    The objective of this research thesis is to find a compact resonant structure which would allow the residual surface impedance of superconductive samples to be simply, quickly and economically characterised. The author first explains why he decided to use a sapphire single-crystal as inner dielectric, given some performance reached by resonant structures equipped with such inner dielectrics, and given constraints adopted from the start. He explains the origin of microwave losses which appear in this type of resonant structure, i.e. respectively the surface impedance as far as metallic losses are concerned, and the sapphire dielectric loss angle for as far as dielectric losses are concerned. The experimental installation and the principle of microwave measurements are described. The performance of different possible solutions of resonant structures from starting criteria is presented. The solution of the cavity-sapphire with a TE 011 resonant mode is derived [fr

  7. AFM imaging and fractal analysis of surface roughness of AlN epilayers on sapphire substrates

    Energy Technology Data Exchange (ETDEWEB)

    Dallaeva, Dinara, E-mail: dinara.dallaeva@yandex.ru [Brno University of Technology, Faculty of Electrical Engineering and Communication, Physics Department, Technická 8, 616 00 Brno (Czech Republic); Ţălu, Ştefan [Technical University of Cluj-Napoca, Faculty of Mechanical Engineering, Department of AET, Discipline of Descriptive Geometry and Engineering Graphics, 103-105 B-dul Muncii Street, Cluj-Napoca 400641, Cluj (Romania); Stach, Sebastian [University of Silesia, Faculty of Computer Science and Materials Science, Institute of Informatics, Department of Biomedical Computer Systems, ul. Będzińska 39, 41-205 Sosnowiec (Poland); Škarvada, Pavel; Tománek, Pavel; Grmela, Lubomír [Brno University of Technology, Faculty of Electrical Engineering and Communication, Physics Department, Technická 8, 616 00 Brno (Czech Republic)

    2014-09-01

    Graphical abstract: - Highlights: • We determined the complexity of 3D surface roughness of aluminum nitride layers. • We used atomic force microscopy and analyzed their fractal geometry. • We determined the fractal dimension of surface roughness of aluminum nitride layers. • We determined the dependence of layer morphology on substrate temperature. - Abstract: The paper deals with AFM imaging and characterization of 3D surface morphology of aluminum nitride (AlN) epilayers on sapphire substrates prepared by magnetron sputtering. Due to the effect of temperature changes on epilayer's surface during the fabrication, a surface morphology is studied by combination of atomic force microscopy (AFM) and fractal analysis methods. Both methods are useful tools that may assist manufacturers in developing and fabricating AlN thin films with optimal surface characteristics. Furthermore, they provide different yet complementary information to that offered by traditional surface statistical parameters. This combination is used for the first time for measurement on AlN epilayers on sapphire substrates, and provides the overall 3D morphology of the sample surfaces (by AFM imaging), and reveals fractal characteristics in the surface morphology (fractal analysis)

  8. Controlling material birefringence in sapphire via self-assembled, sub-wavelength defects

    Science.gov (United States)

    Singh, Astha; Sharma, Geeta; Ranjan, Neeraj; Mittholiya, Kshitij; Bhatnagar, Anuj; Singh, B. P.; Mathur, Deepak; Vasa, Parinda

    2018-02-01

    Birefringence is the optical property of a material having a refractive index that depends on the polarization and propagation direction of light. Generally, this is an intrinsic optical property of a material and cannot be altered. Here, we report a novel technique—direct laser writing—that enables us to control the natural, material birefringence of sapphire over a broad range of wavelengths. The broadband form birefringence originating from self-assembled, periodic array of sub-wavelength (˜ 50-200 nm) defects created by laser writing, can enhance, suppress or maintain the material birefringence of sapphire without affecting its transparency range in visible or its surface quality.

  9. Single-transverse-mode Ti:sapphire rib waveguide laser

    NARCIS (Netherlands)

    Grivas, C.; Shepherd, D.P.; May-Smith, T.C.; Eason, R.W.; Pollnau, Markus

    2005-01-01

    Laser operation of Ti:sapphire rib waveguides fabricated using photolithography and ion beam etching in pulsed laser deposited layers is reported. Polarized laser emission was observed at 792.5 nm with an absorbed pump power threshold of 265 mW, which is more than a factor of 2 lower in comparison

  10. Heteroepitaxial growth of CuInS2 thin films on sapphire by radio frequency reactive sputtering

    International Nuclear Information System (INIS)

    He, Y.B.; Kriegseis, W.; Meyer, B.K.; Polity, A.; Serafin, M.

    2003-01-01

    Direct heteroepitaxial growth of uniform stoichiometric CuInS 2 (CIS) thin films on sapphire (0001) substrates has been achieved by radio frequency reactive sputtering. X-ray ω-2θ scans reveal that the sputtered layers grow in a (112) orientation with a chalcopyrite structure. A rocking curve full width at half maximum of about 0.05 deg. (180 arc sec) for the (112) peak demonstrates a nearly perfect out-of-plane arrangement of CIS (112) parallel sapphire (0001). X-ray diffraction Phi scans further illustrate an excellent in-plane ordering of CIS [1-bar10] parallel sapphire (101-bar0). The sputtered thin CIS epilayers had a smooth surface with a typical root-mean-square roughness of about 3.3 nm as evaluated by atomic force microscopy. The epitaxial growth of tetragonal CIS on hexagonal sapphire provides evidence that heteroepitaxial growth may be realized between structures of different symmetry, such as films of cubic or tetragonal structures on hexagonal substrates or vice versa

  11. Reduction of Residual Stresses in Sapphire Cover Glass Induced by Mechanical Polishing and Laser Chamfering Through Etching

    Directory of Open Access Journals (Sweden)

    Shih-Jeh Wu

    2016-10-01

    Full Text Available Sapphire is a hard and anti-scratch material commonly used as cover glass of mobile devices such as watches and mobile phones. A mechanical polishing using diamond slurry is usually necessary to create mirror surface. Additional chamfering at the edge is sometimes needed by mechanical grinding. These processes induce residual stresses and the mechanical strength of the sapphire work piece is impaired. In this study wet etching by phosphate acid process is applied to relief the induced stress in a 1” diameter sapphire cover glass. The sapphire is polished before the edge is chamfered by a picosecond laser. Residual stresses are measured by laser curvature method at different stages of machining. The results show that the wet etching process effectively relief the stress and the laser machining does not incur serious residual stress.

  12. Development of frequency tunable Ti:sapphire laser and dye laser pumped by a pulsed Nd:YAG laser

    International Nuclear Information System (INIS)

    Yi, Jong Hoon; Horn, Roland; Wendt, K.

    2001-01-01

    We investigated lasing characteristics of two kinds of tunable laser, liquid dye laser and solid Ti:sapphire crystal laser, pumped by high pulse repetition rate Nd:YAG laser. Dye laser showed drastically reduced pulsewidth compared with that of pump laser and it also contained large amount of amplified spontaneous emission. Ti:sapphire laser showed also reduced pulsewidth. But, the laser conversion pump laser and Ti:sapphire laser pulse, we used a Brewster-cut Pockel's cell for Q-switching. The laser was frequency doubled by a type I BBO crystal outside of the cavity.

  13. Transfer-free graphene synthesis on sapphire by catalyst metal agglomeration technique and demonstration of top-gate field-effect transistors

    International Nuclear Information System (INIS)

    Miyoshi, Makoto; Arima, Yukinori; Kubo, Toshiharu; Egawa, Takashi; Mizuno, Masaya; Soga, Tetsuo

    2015-01-01

    Transfer-free graphene synthesis was performed on sapphire substrates by using the catalyst metal agglomeration technique, and the graphene film quality was compared to that synthesized on sputtered SiO 2 /Si substrates. Raman scattering measurements indicated that the graphene film on sapphire has better structural qualities than that on sputtered SiO 2 /Si substrates. The cross-sectional transmission microscopic study also revealed that the film flatness was drastically improved by using sapphire substrates instead of sputtered SiO 2 /Si substrates. These quality improvements seemed to be due the chemical and thermal stabilities of sapphire. Top-gate field-effect transistors were fabricated using the graphene films on sapphire, and it was confirmed that their drain current can be modulated with applied gate voltages. The maximum field-effect mobilities were estimated to be 720 cm 2 /V s for electrons and 880 cm 2 /V s for holes, respectively

  14. Transfer-free graphene synthesis on sapphire by catalyst metal agglomeration technique and demonstration of top-gate field-effect transistors

    Energy Technology Data Exchange (ETDEWEB)

    Miyoshi, Makoto, E-mail: miyoshi.makoto@nitech.ac.jp; Arima, Yukinori; Kubo, Toshiharu; Egawa, Takashi [Research Center for Nano Device and Advanced Materials, Nagoya Institute of Technology, Nagoya 466-8555 (Japan); Mizuno, Masaya [Research Center for Nano Device and Advanced Materials, Nagoya Institute of Technology, Nagoya 466-8555 (Japan); Department of Frontier Materials, Nagoya Institute of Technology, Nagoya 466-8555 (Japan); Soga, Tetsuo [Department of Frontier Materials, Nagoya Institute of Technology, Nagoya 466-8555 (Japan)

    2015-08-17

    Transfer-free graphene synthesis was performed on sapphire substrates by using the catalyst metal agglomeration technique, and the graphene film quality was compared to that synthesized on sputtered SiO{sub 2}/Si substrates. Raman scattering measurements indicated that the graphene film on sapphire has better structural qualities than that on sputtered SiO{sub 2}/Si substrates. The cross-sectional transmission microscopic study also revealed that the film flatness was drastically improved by using sapphire substrates instead of sputtered SiO{sub 2}/Si substrates. These quality improvements seemed to be due the chemical and thermal stabilities of sapphire. Top-gate field-effect transistors were fabricated using the graphene films on sapphire, and it was confirmed that their drain current can be modulated with applied gate voltages. The maximum field-effect mobilities were estimated to be 720 cm{sup 2}/V s for electrons and 880 cm{sup 2}/V s for holes, respectively.

  15. Interface amorphization in hexagonal boron nitride films on sapphire substrate grown by metalorganic vapor phase epitaxy

    Science.gov (United States)

    Yang, Xu; Nitta, Shugo; Pristovsek, Markus; Liu, Yuhuai; Nagamatsu, Kentaro; Kushimoto, Maki; Honda, Yoshio; Amano, Hiroshi

    2018-05-01

    Hexagonal boron nitride (h-BN) films directly grown on c-plane sapphire substrates by pulsed-mode metalorganic vapor phase epitaxy exhibit an interlayer for growth temperatures above 1200 °C. Cross-sectional transmission electron microscopy shows that this interlayer is amorphous, while the crystalline h-BN layer above has a distinct orientational relationship with the sapphire substrate. Electron energy loss spectroscopy shows the energy-loss peaks of B and N in both the amorphous interlayer and the overlying crystalline h-BN layer, while Al and O signals are also seen in the amorphous interlayer. Thus, the interlayer forms during h-BN growth through the decomposition of the sapphire at elevated temperatures.

  16. Seasonal variations in red deer (Cervus elaphus) hematology related to antler growth and biometrics measurements.

    Science.gov (United States)

    Gaspar-López, Enrique; Landete-Castillejos, Tomás; Estevez, Jose Antonio; Ceacero, Francisco; Gallego, Laureano; García, Andrés Jose

    2011-04-01

    The aim of the study was to relate seasonal hematology changes with the rest of physiological variations suffered by red deer, such as antler and biometrics cycle, and to assess the relationship between hematology and the effort performed in antler development. Blood samples were taken from 21 male red deer every 4 weeks during 18 months. Samples were analyzed for the main hematological parameters. Simultaneously, biometrics measurements were taken, such as antler length, body weight, body condition score, testicular diameter (TD), and thoracic and neck girth. All the blood cell types (erythrocytes, leukocytes, and platelets) showed seasonal variations, increasing as antler cleaning approached, as did hematocrit and hemoglobin. The final size of antlers was negatively related to leukocyte count, nonlymphoid leukocyte count, red cell distribution width, mean corpuscular hemoglobin, mean platelet volume, and TD, whereas it was positively related to body condition during antler growth. Huge seasonal variations in some hematological values have been found to be related to changes in antler and biometrics measurements. Since these variations are even greater than the caused by deer handling, they should be taken into account when evaluating hematology in deer populations. Copyright © 2011 Wiley-Liss, Inc., A Wiley Company.

  17. Association between the ABO locus and hematological traits in Korean

    Directory of Open Access Journals (Sweden)

    Hong Kyung-Won

    2012-09-01

    Full Text Available Abstract Background Recently, genome-wide association studies identified a pleiotropic gene locus, ABO, as being significantly associated with hematological traits. To confirm the effects of ABO on hematological traits, we examined the link between the ABO locus and hematological traits in Korean population-based cohorts. Results Six tagging SNPs for ABO were analyzed with regard to their effects on hematological traits [white blood cell count (WBC, red blood cell count (RBC, platelet (Plat, mean corpuscular volume (MCV, and mean corpuscular haemoglobin concentration (MCHC]. Linear regression analyses were performed, controlling for recruitment center, sex, and age as covariates. Of the 6 tagging SNPs, 3 (rs2073823, rs8176720, and rs495828 and 3 (rs2073823, rs8176717, and rs687289 were significantly associated with RBC and MCV, respectively (Bonferroni correction p-value criteria r2s = 0.99. Of the remaining 3 SNPs (rs8176720, rs8176717 and rs687289, rs8176717 generated an independent signal with moderate p-value (= 0.045 when it was adjusted for by rs2073823 (the most significant SNP. We also identified a copy number variation (CNV that was tagged by the SNP rs8176717, the minor allele of which correlated with the deletion allele of CNV. Our haplotype analysis indicated that the haplotype that contained the CNV deletion was significantly associated with MCV (β ± se = 0.363 ± 0.118, p =2.09 × 10-3. Conclusions Our findings confirm that ABO is one of the genetic factors that are associated with hematological traits in the Korean population. This result is notable, because GWASs fail to evaluate the link between a CNV and phenotype traits.

  18. Thermal stress resistance of ion implanted sapphire crystals

    International Nuclear Information System (INIS)

    Gurarie, V.N.; Jamieson, D.N.; Szymanski, R.; Orlov, A.V.; Williams, J.S.; Conway, M.

    1999-01-01

    Monocrystals of sapphire have been subjected to ion implantation with 86 keV Si - and 80 keV Cr - ions to doses in the range of 5x10 14 -5x10 16 cm -2 prior to thermal stress testing in a pulsed plasma. Above a certain critical dose ion implantation is shown to modify the near-surface structure of samples by introducing damage, which makes crack nucleation easier under the applied stress. The effect of ion dose on the stress resistance is investigated and the critical doses which produce a noticeable change in the stress resistance are determined. The critical dose for Si ions is shown to be much lower than that for Cr - ions. However, for doses exceeding 2x10 16 cm -2 the stress resistance parameter decreases to approximately the same value for both implants. The size of the implantation-induced crack nucleating centers and the density of the implantation-induced defects are considered to be the major factors determining the stress resistance of sapphire crystals irradiated with Si - and Cr - ions

  19. Change in equilibrium position of misfit dislocations at the GaN/sapphire interface by Si-ion implantation into sapphire—I. Microstructural characterization

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung Bo, E-mail: bolee@snu.ac.kr; Han, Heung Nam, E-mail: hnhan@snu.ac.kr; Lee, Dong Nyung [Department of Materials Science and Engineering and Research Institute of Advanced Materials (RIAM), Seoul National University, Seoul 151-744 (Korea, Republic of); Ju, Jin-Woo [Korea Photonics Technology Institute, Gwangju 500-779 (Korea, Republic of); Kim, Young-Min; Yoo, Seung Jo; Kim, Jin-Gyu [Korea Basic Science Institute, Daejeon 305-806 (Korea, Republic of)

    2015-07-15

    Much research has been done to reduce dislocation densities for the growth of GaN on sapphire, but has paid little attention to the elastic behavior at the GaN/sapphire interface. In this study, we have examined effects of the addition of Si to a sapphire substrate on its elastic property and on the growth of GaN deposit. Si atoms are added to a c-plane sapphire substrate by ion implantation. The ion implantation results in scratches on the surface, and concomitantly, inhomogeneous distribution of Si. The scratch regions contain a higher concentration of Si than other regions of the sapphire substrate surface, high-temperature GaN being poorly grown there. However, high-temperature GaN is normally grown in the other regions. The GaN overlayer in the normally-grown regions is observed to have a lower TD density than the deposit on the bare sapphire substrate (with no Si accommodated). As compared with the film on an untreated, bare sapphire, the cathodoluminescence defect density decreases by 60 % for the GaN layer normally deposited on the Si-ion implanted sapphire. As confirmed by a strain mapping technique by transmission electron microscopy (geometric phase analysis), the addition of Si in the normally deposited regions forms a surface layer in the sapphire elastically more compliant than the GaN overlayer. The results suggest that the layer can largely absorb the misfit strain at the interface, which produces the overlayer with a lower defect density. Our results highlight a direct correlation between threading-dislocation density in GaN deposits and the elastic behavior at the GaN/sapphire interface, opening up a new pathway to reduce threading-dislocation density in GaN deposits.

  20. Structural, transport and microwave properties of 123/sapphire films: Thickness effect

    Energy Technology Data Exchange (ETDEWEB)

    Predtechensky, MR.; Smal, A.N.; Varlamov, Y.D. [Institute of Thermophysics, Novosibirsk (Russian Federation)] [and others

    1994-12-31

    The effect of thickness and growth conditions on the structure and microwave properties has been investigated for the 123/sapphire films. It has been shown that in the conditions of epitaxial growth and Al atoms do not diffuse from substrate into the film and the films with thickness up to 100nm exhibit the excellent DC properties. The increase of thickness of GdBaCuO films causes the formation of extended line-mesh defects and the increase of the surface resistance (R{sub S}). The low value of surface resistance R{sub S}(75GHz,77K)=20 mOhm has been obtained for the two layer YBaCuO/CdBaCuO/sapphire films.

  1. Neurosurgery contact handheld probe based on sapphire shaped crystal

    Science.gov (United States)

    Shikunova, I. A.; Stryukov, D. O.; Rossolenko, S. N.; Kiselev, A. M.; Kurlov, V. N.

    2017-01-01

    A handheld contact probe based on sapphire shaped crystal is developed for intraoperative spectrally-resolved optical diagnostics, laser coagulation and aspiration of malignant brain tissue. The technology was integrated into the neurosurgical workflow for intraoperative real-time identification and removing of invasive brain cancer.

  2. Study of sapphire probe tip wear when scanning on different materials

    International Nuclear Information System (INIS)

    Nicolet, Anaïs; Küng, Alain; Meli, Felix

    2012-01-01

    The accuracy of today's coordinate measuring machines (CMM) has reached a level at which exact knowledge of each component is required. The role of the probe tip is particularly crucial as it is in contact with the sample surface. Understanding how the probe tip wears off will help to narrow the measurement errors. In this work, wear of a sapphire sphere was studied for different scanning conditions and with different sample materials. Wear depth on the probe was investigated using an automated process in situ on the METAS micro-CMM and completed by measurements with an atomic force microscope. We often found a linear dependence between the wear depth and the scan length ranging from 0.5 to 9 nm m −1 , due to variations in scan speed, contact force or sample material. In the case of steel, the wear rate is proportional to the scan speed, while for aluminum several processes seem to interact. A large amount of debris was visible after the tests. Except for aluminum, wear was visible only on the sphere and not on the sample. Sapphire/steel is the worst combination in terms of wear, whereas the combination sapphire/ceramic exhibits almost no wear. (paper)

  3. 42 CFR 493.1269 - Standard: Hematology.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Hematology. 493.1269 Section 493.1269 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Systems § 493.1269 Standard: Hematology. (a) For manual cell counts performed using a hemocytometer— (1...

  4. Antireflection coatings for intraocular lenses of sapphire and fianite

    Energy Technology Data Exchange (ETDEWEB)

    Babin, A.A.; Konoplev, Yu.N.; Mamaev, Yu.A. [Inst. of Applied Physics, Nizhnii Novgorod (Russian Federation)] [and others

    1995-10-01

    Broadband antireflection coatings for intraocular lenses of sapphire and fianite are calculated and implemented practically. Their residual reflectance in the liquid with a refracting index of 1.336 is below 0.2% from each face virtually over the entire visible region. 7 refs., 2 figs., 2 tabs.

  5. Scintillation of sapphire under particle excitation at low temperature

    International Nuclear Information System (INIS)

    Amare, J; Beltran, B; Cebrian, S; Coron, N; Dambier, G; GarcIa, E; Gomez, H; Irastorza, I G; Leblanc, J; Luzon, G; Marcillac, P de; Martinez, M; Morales, J; Ortiz de Solorzano, A; Pobes, C; Puimedon, J; Redon, T; RodrIguez, A; Ruz, J; Sarsa, M L; Torres, L; Villar, J A

    2006-01-01

    The scintillation properties of undoped sapphire at very low temperature have been studied in the framework of the ROSEBUD (Rare Objects SEarch with Bolometers UnDerground) Collaboration devoted to dark matter searches. We present an estimation of its light yield under gamma, alpha and neutron excitation

  6. Occurrence and elimination of in-plane misoriented crystals in AlN epilayers on sapphire via pre-treatment control

    International Nuclear Information System (INIS)

    Wang Hu; Xiong Hui; Wu Zhi-Hao; Yu Chen-Hui; Tian Yu; Dai Jiang-Nan; Fang Yan-Yan; Zhang Jian-Bao; Chen Chang-Qing

    2014-01-01

    AlN epilayers are grown directly on sapphire (0001) substrates each of which has a low temperature AlN nucleation layer. The effects of pretreatments of sapphire substrates, including exposures to NH 3 /H 2 and to H 2 only ambients at different temperatures, before the growth of AlN epilayers is investigated. In-plane misoriented crystals occur in N-polar AlN epilayers each with pretreatment in a H 2 only ambient, and are characterized by six 60°-apart peaks with splits in each peak in (101-bar 2) phi scan and two sets of hexagonal diffraction patterns taken along the [0001] zone axis in electron diffraction. These misoriented crystals can be eliminated in AlN epilayers by the pretreatment of sapphire substrates in the NH 3 /H 2 ambient. AlN epilayers by the pretreatment of sapphire substrates in the NH 3 /H 2 ambient are Al-polar. Our results show the pretreatments and the nucleation layers are responsible for the polarities of the AlN epilayers. We ascribe these results to the different strain relaxation mechanisms induced by the lattice mismatch of AlN and sapphire. (interdisciplinary physics and related areas of science and technology)

  7. Frequency-doubled DBR-tapered diode laser for direct pumping of Ti:sapphire lasers generating sub-20 fs pulses

    DEFF Research Database (Denmark)

    Müller, André; Jensen, Ole Bjarlin; Unterhuber, Angelika

    2011-01-01

    For the first time a single-pass frequency doubled DBR-tapered diode laser suitable for pumping Ti:sapphire lasers generating ultrashort pulses is demonstrated. The maximum output powers achieved when pumping the Ti:sapphire laser are 110 mW (CW) and 82 mW (mode-locked) respectively at 1.2 W...... of pump power. This corresponds to a reduction in optical conversion efficiencies to 75% of the values achieved with a commercial diode pumped solid-state laser. However, the superior electro-optical efficiency of the diode laser improves the overall efficiency of the Ti:sapphire laser by a factor > 2....... The optical spectrum emitted by the Ti:sapphire laser when pumped with our diode laser shows a spectral width of 112 nm (FWHM). Based on autocorrelation measurements, pulse widths of less than 20 fs can therefore be expected....

  8. Frequency-doubled DBR-tapered diode laser for direct pumping of Ti:sapphire lasers generating sub-20 fs pulses.

    Science.gov (United States)

    Müller, André; Jensen, Ole Bjarlin; Unterhuber, Angelika; Le, Tuan; Stingl, Andreas; Hasler, Karl-Heinz; Sumpf, Bernd; Erbert, Götz; Andersen, Peter E; Petersen, Paul Michael

    2011-06-20

    For the first time a single-pass frequency doubled DBR-tapered diode laser suitable for pumping Ti:sapphire lasers generating ultrashort pulses is demonstrated. The maximum output powers achieved when pumping the Ti:sapphire laser are 110 mW (CW) and 82 mW (mode-locked) respectively at 1.2 W of pump power. This corresponds to a reduction in optical conversion efficiencies to 75% of the values achieved with a commercial diode pumped solid-state laser. However, the superior electro-optical efficiency of the diode laser improves the overall efficiency of the Ti:sapphire laser by a factor > 2. The optical spectrum emitted by the Ti:sapphire laser when pumped with our diode laser shows a spectral width of 112 nm (FWHM). Based on autocorrelation measurements, pulse widths of less than 20 fs can therefore be expected.

  9. Oral microflora in children with hematologic malignancies

    Directory of Open Access Journals (Sweden)

    M. F. Vecherkovskaya

    2015-06-01

    Full Text Available The goal was a comprehensive study of oral microflora in healthy children and those with hematologic malignancies, based on the analysis of mixed microbial biofilms composition, isolation and identification of new previously unknown microorganisms. The material was obtained in children with hematological diseases in remission, 2–10 years aged, and for the control group from St. Petersburg schoolchildren and in kindergartens. We used microbiological, biochemical and molecular genetic methods, including electron microscopy, proteomic analysis, sequencing and complete genome annotation. Microorganisms of 23 genera isolated as pure cultures and identified by biochemical activity from mixed microbial biofilm derived from saliva of healthy and sick children. In microflora of children with hematologic malignancies a previously unknown type of streptococci with a large number of antibiotic resistance genes was revealed. Differences in oral microbiota composition of healthy children and children with hematological diseases in remission were revealed. The microbiota of children with hematologic malignancies contains more genes controlling antibiotic resistance. Also, it was observed previously unknown bacterium of the genus Streptococcus.

  10. Oral microflora in children with hematologic malignancies

    Directory of Open Access Journals (Sweden)

    M. F. Vecherkovskaya

    2015-01-01

    Full Text Available The goal was a comprehensive study of oral microflora in healthy children and those with hematologic malignancies, based on the analysis of mixed microbial biofilms composition, isolation and identification of new previously unknown microorganisms. The material was obtained in children with hematological diseases in remission, 2–10 years aged, and for the control group from St. Petersburg schoolchildren and in kindergartens. We used microbiological, biochemical and molecular genetic methods, including electron microscopy, proteomic analysis, sequencing and complete genome annotation. Microorganisms of 23 genera isolated as pure cultures and identified by biochemical activity from mixed microbial biofilm derived from saliva of healthy and sick children. In microflora of children with hematologic malignancies a previously unknown type of streptococci with a large number of antibiotic resistance genes was revealed. Differences in oral microbiota composition of healthy children and children with hematological diseases in remission were revealed. The microbiota of children with hematologic malignancies contains more genes controlling antibiotic resistance. Also, it was observed previously unknown bacterium of the genus Streptococcus.

  11. 42 CFR 493.851 - Standard; Hematology.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard; Hematology. 493.851 Section 493.851 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... These Tests § 493.851 Standard; Hematology. (a) Failure to attain a score of at least 80 percent of...

  12. Sapphire implant based neuro-complex for deep-lying brain tumors phototheranostics

    Science.gov (United States)

    Sharova, A. S.; Maklygina, YU S.; Yusubalieva, G. M.; Shikunova, I. A.; Kurlov, V. N.; Loschenov, V. B.

    2018-01-01

    The neuro-complex as a combination of sapphire implant optical port and osteoplastic biomaterial "Collapan" as an Aluminum phthalocyanine nanoform photosensitizer (PS) depot was developed within the framework of this study. The main goals of such neuro-complex are to provide direct access of laser radiation to the brain tissue depth and to transfer PS directly to the pathological tissue location that will allow multiple optical phototheranostics of the deep-lying tumor region without repeated surgical intervention. The developed complex spectral-optical properties research was carried out by photodiagnostics method using the model sample: a brain tissue phantom. The optical transparency of sapphire implant allows obtaining a fluorescent signal with high accuracy, comparable to direct measurement "in contact" with the tissue.

  13. Pattern of Duplicate Presentations at National Hematology-Oncology Meetings: Influence of the Pharmaceutical Industry.

    Science.gov (United States)

    Ramchandren, Radhakrishnan; Schiffer, Charles A

    2016-03-01

    The major large US hematology-oncology meetings sponsored by the American Society of Hematology (ASH) and American Society of Clinical Oncology (ASCO) have specific guidelines in place discouraging submission of scientific information presented previously at other meetings. Nonetheless, duplicate submissions are frequent. The incidence and motivations for duplicate hematologic presentations and the influence of the pharmaceutical industry on this process have not been thoroughly analyzed. Therefore, were viewed four consecutive ASH and ASCO meetings to assess the frequency of duplicate abstract presentations. All abstracts presented at ASCO2010 in the area of malignant hematology were compared with abstracts from ASCO and ASH 2009 and ASH 2010, and funding sources were reviewed. More than half (54%) of all abstracts submitted to ASCO 2010 acknowledged pharmaceutical company support. Almost one third (31%) of ASCO 2010 abstracts were resubmitted in the 2-year time period, and it was notable that a high fraction (75%) of these duplicate abstracts had pharmaceutical industry sponsorship, compared with 42% of the abstracts that were submitted only once. Despite current guidelines prohibiting duplicate abstract presentation, a substantial proportion (31%) of abstracts at large international hematology-oncology meetings are duplicative, with potential negative consequences. In addition, a disproportionate percentage of the duplicate abstracts rely on pharmaceutical industry support (75%), suggesting that marketing strategies may be a motivation for some of these repetitive submissions.

  14. Hematological effects for the Khar'kov region population and possible ways for correction using domestic preparations

    International Nuclear Information System (INIS)

    Timchenko, V.G.; Frenkel', L.A.; Tajsenyuk, L.A.

    1992-01-01

    Character and structure of changes of hematopoiesis for persons subjected to low-dose irradiation connected with the Chernobyl' NPP accident (for the period of 1986-1991), peculiarities of the hematological effect dynamics and capabilities for its correction were analyzed. Data of clinical and laboratory studies of 8450 persons living in the Khar'kov region, who took part in the accident effect elimination (AEE), were analyzed. Observation of the hematopoiesis dynamics for persons, who took part in AEE, during 5 years revealed growth in total number of hematological effects from the first to fifth year from 8-9% up to 50%, as well as the structure change, namely, prevalence of leukopenia (56%) in the first year of surveillance changed by increase in the number of anemias from 39 up to 84% and decrease in the number of leukopenia up to 3.3% in the fifth year of surveillance. The preparations cooping hematological effects were tested in experiments with rats. These were preparations of the classes of flavones, alginates, humines produced using domestic vegetable source materials. 1 tab

  15. Weights, hematology and serum chemistry of free-ranging brown boobies (Sula leucogaster) in Johnston Atoll, Central Pacific

    Science.gov (United States)

    Work, Thierry M.

    1999-01-01

    Hematologic and serum chemistry values are reported for 105 brown boobies (Sula leucogaster) from Johnston Atoll, Central Pacific. Hematocrit, estimated total plasma solids, total and differential white cell counts, serum glucose, calcium, phosphorus, uric acid, total protein, albumin, globulin, aspartate aminotransferase, and creatinine phosphokinase were analyzed. Hematologic and serum chemistry values varied with age and sex. Values were compared with those of red-footed boobies and other tropical and temperate marine pelecaniforms.

  16. A Century of Sapphire Crystal Growth

    Science.gov (United States)

    2004-05-17

    should be aware that notwithstanding any other provision of law , no person shall be subject to a penalty for failing to comply with a collection of...and ruby were oxides of the elements aluminum and silicon.1 In 1817, J. L. Gay- Lussac found that pure aluminum oxide (also called alumina) could...thought to consist of Al2O3 and SiO2 •1817: Gay- Lussac : •1840: Rose: Found SiO2 in sapphire is from agate mortar used for grinding •1837-72: Gaudin

  17. Baccaurea angulata fruit juice ameliorates altered hematological and biochemical biomarkers in diet-induced hypercholesterolemic rabbits.

    Science.gov (United States)

    Ahmed, Idris Adewale; Mikail, Maryam Abimbola; Ibrahim, Muhammad

    2017-06-01

    Hypercholesterolemia is an important risk factor linked to the alteration of blood hematology and clinical chemistry associated with the development and progression of atherosclerosis. Previous studies have demonstrated the safety and potential health benefits of Baccaurea angulata (BA) fruit. We hypothesized that the oral administration of BA fruit juice could ameliorate the alteration in the hematological and biochemical biomarkers of diet-induced hypercholesterolemic rabbits. The aim of this study was to investigate the effects of different doses of BA juice on the hematological and biochemical biomarkers in normo- and hypercholesterolemic rabbits. Thirty-five healthy adult New Zealand White rabbits were assigned to seven different groups for 90days of diet intervention. Four atherogenic groups were fed a 1% cholesterol diet and 0, 0.5, 1.0, and 1.5mL of BA juice per kg of rabbit daily. The other three normal groups were fed a commercial rabbit pellet diet and 0, 0.5, and 1.0mL of BA juice per kg of rabbit daily. Baseline and final blood samples after 90days of repeated administration BA juice were analyzed for hematological parameters while serum, aortic and hepatic lysates were analyzed for lipid profiles and other biochemical biomarkers. The alteration of the hemopoietic system, physiological changes in serum and tissues lipid profiles and other biochemicals resulting from the consumption of a high-cholesterol diet were significantly (Pjuice. Improvements of the biomarkers in rabbits were dose-dependent, markedly enhanced at the highest dose of juice (1.5mL/kg/day). The results suggest potential health benefits of the antioxidant-rich BA fruit juice against hypercholesterolemia-associated hematological and biochemical alterations in the rabbit. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Influence of interfacial reactions on the fiber push-out behavior in sapphire fiber-reinforced-NiAl(Yb) composites

    International Nuclear Information System (INIS)

    Tewari, S.N.; Asthana, R.; Tiwari, R.; Bowman, R.R.

    1993-01-01

    The influence of microstructure of the fiber-matrix interface on the fiber push-out behavior has been examined in sapphire fiber-reinforced NiAl and NiAl(Yb) matrix composites synthesized using powder metallurgy techniques combined with zone directional solidification (DS). The push-out stress-displacement curves were observed to consist of an initial 'pseudoelastic' region, wherein the stress increased linearly with displacement, followed by an 'inelastic' region, where the slope of the stress-displacement plot decreased until a maximum stress was reached, and the subsequent stress drop to a constant 'frictional' stress. Chemical reaction between the fiber and the matrix resulted in higher interfacial shear strength in powder cloth processed sapphire-NiAl(Yb) composites as compared to the sapphire-NiAl composites. Grain boundaries in contact with the fibers on the back face of the push-out samples were the preferred sites for crack nucleation in PM composites. The frictional stress was independent of the microstructure and processing variables for NiAl composites, but showed strong dependence on these variables for the NiAl(Yb) composites. The DS processing enhanced the fiber-matrix interfacial shear strength of feedstock PM-NiAl/sapphire composites. However, it reduced the interfacial shear strength of PM-NiAl(Yb)-sapphire composites

  19. Micromachining and dicing of sapphire, gallium nitride and micro LED devices with UV copper vapour laser

    International Nuclear Information System (INIS)

    Gu, E.; Jeon, C.W.; Choi, H.W.; Rice, G.; Dawson, M.D.; Illy, E.K.; Knowles, M.R.H.

    2004-01-01

    Gallium nitride (GaN) and sapphire are important materials for fabricating photonic devices such as high brightness light emitting diodes (LEDs). These materials are strongly resistant to wet chemical etching and also, low etch rates restrict the use of dry etching. Thus, to develop alternative high resolution processing and machining techniques for these materials is important in fabricating novel photonic devices. In this work, a repetitively pulsed UV copper vapour laser (255 nm) has been used to machine and dice sapphire, GaN and micro LED devices. Machining parameters were optimised so as to achieve controllable machining and high resolution. For sapphire, well-defined grooves 30 μm wide and 430 μm deep were machined. For GaN, precision features such as holes on a tens of micron length scale have been fabricated. By using this technique, compact micro LED chips with a die spacing 100 and a 430 μm thick sapphire substrate have been successfully diced. Measurements show that the performances of LED devices are not influenced by the UV laser machining. Our results demonstrate that the pulsed UV copper vapour laser is a powerful tool for micromachining and dicing of photonic materials and devices

  20. Transmittance enhancement of sapphires with antireflective subwavelength grating patterned UV polymer surface structures by soft lithography.

    Science.gov (United States)

    Lee, Soo Hyun; Leem, Jung Woo; Yu, Jae Su

    2013-12-02

    We report the total and diffuse transmission enhancement of sapphires with the ultraviolet curable SU8 polymer surface structures consisting of conical subwavelength gratings (SWGs) at one- and both-side surfaces for different periods. The SWGs patterns on the silicon templates were transferred into the SU8 polymer film surface on sapphires by a simple and cost-effective soft lithography technique. For the fabricated samples, the surface morphologies, wetting behaviors, and optical characteristics were investigated. For theoretical optical analysis, a rigorous coupled-wave analysis method was used. At a period of 350 nm, the sample with SWGs on SU8 film/sapphire exhibited a hydrophobic surface and higher total transmittance compared to the bare sapphire over a wide wavelength of 450-1000 nm. As the period of SWGs was increased, the low total transmittance region of < 85% was shifted towards the longer wavelengths and became broader while the diffuse transmittance was increased (i.e., larger haze ratio). For the samples with SWGs at both-side surfaces, the total and diffuse transmittance spectra were further enhanced compared to the samples with SWGs at one-side surface. The theoretical optical calculation results showed a similar trend to the experimentally measured data.

  1. Design of all solid state tunable single-mode Ti: sapphire laser for nuclear industry

    International Nuclear Information System (INIS)

    Lee, J.H.; Nam, S.M.; Lee, Y.J.; Lee, J.M.; Horn, Roland E.; Wendt, Klaus

    1999-01-01

    We designed a Ti:Sapphire laser pumped by a diode laser pumped solid state laser (DPSSL). The DPSSL was intra-cavity frequency doubled and it had 20 W output power. The Ti:Sapphire laser was designed for single longitudinal mode lasing. For single mode lasing, the laser used several solid etalons. We simulated temporal evolution of the laser pulse and single pass amplification rate of the photons in each modes from rate equations. From the result, we found that single mode lasing is viable in this cavity

  2. Eosinophilic Dermatosis of Hematologic Malignancy.

    Science.gov (United States)

    Lucas-Truyols, S; Rodrigo-Nicolás, B; Lloret-Ruiz, C; Quecedo-Estébanez, E

    Dermatosis characterized by tissue eosinophilia arising in the context of hematologic disease is known as eosinophilic dermatosis of hematologic malignancy. The most commonly associated malignancy is chronic lymphocytic leukemia. Eosinophilic dermatosis of hematologic malignancy is a rare condition with a wide variety of clinical presentations, ranging from papules, erythematous nodules, or blisters that simulate arthropod bites, to the formation of true plaques of differing sizes. Histology reveals the presence of abundant eosinophils. We present 4 new cases seen in Hospital Arnau de Vilanova, Valencia, during the past 7 years. Three of these cases were associated with chronic lymphocytic leukemia and 1 with mycosis fungoides. It is important to recognize this dermatosis as it can indicate progression of the underlying disease, as was the case in 3 of our patients. Copyright © 2017 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Musculoskeletal Imaging Findings of Hematologic Malignancies.

    Science.gov (United States)

    Navarro, Shannon M; Matcuk, George R; Patel, Dakshesh B; Skalski, Matthew; White, Eric A; Tomasian, Anderanik; Schein, Aaron J

    2017-01-01

    Hematologic malignancies comprise a set of prevalent yet clinically diverse diseases that can affect every organ system. Because blood components originate in bone marrow, it is no surprise that bone marrow is a common location for both primary and metastatic hematologic neoplasms. Findings of hematologic malignancy can be seen with most imaging modalities including radiography, computed tomography (CT), technetium 99m ( 99m Tc) methylene diphosphonate (MDP) bone scanning, fluorine 18 ( 18 F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT, and magnetic resonance (MR) imaging. Because of the diversity of imaging appearances and clinical behavior of this spectrum of disease, diagnosis can be challenging, and profound understanding of the underlying pathophysiologic changes and current treatment modalities can be daunting. The appearance of normal bone marrow at MR imaging and FDG PET/CT is also varied due to dynamic compositional changes with normal aging and in response to hematologic demand or treatment, which can lead to false-positive interpretation of imaging studies. In this article, the authors review the normal maturation and imaging appearance of bone marrow. Focusing on lymphoma, leukemia, and multiple myeloma, they present the spectrum of imaging findings of hematologic malignancy affecting the musculoskeletal system and the current imaging tools available to the radiologist. They discuss the imaging findings of posttreatment bone marrow and review commonly used staging systems and consensus recommendations for appropriate imaging for staging, management, and assessment of clinical remission. © RSNA, 2017.

  4. Some hematological and biochemical parameters in smokeless ...

    African Journals Online (AJOL)

    AJB SERVER

    2007-01-04

    Jan 4, 2007 ... The effect of Jharda powder (smokeless tobacco) on some hematological and biochemical parameters in consumers was investigated. Hematological parameters including hemoglobin content and white blood cell and leukocyte counts were higher in jharda powder consumers, while monocytes and.

  5. The Influence of Surface Anisotropy Crystalline Structure on Wetting of Sapphire by Molten Aluminum

    Science.gov (United States)

    Aguilar-Santillan, Joaquin

    2013-05-01

    The wetting of sapphire by molten aluminum was investigated by the sessile drop technique from 1073 K to 1473 K (800 °C to 1200 °C) at PO2 <10-15 Pa under Ar atmosphere. This study focuses on sapphire crystalline structure and its principle to the interface. The planes " a" and " b" are oxygen terminated structures and wet more by Al, whereas the " c" plane is an aluminum terminated structure. A wetting transition at 1273 K (1000 °C) was obtained and a solid surface tension proves the capillarity trends of the couple.

  6. Cytogenetic and hematological studies in the workers occupationally exposed to low levels of ionizing radiation

    International Nuclear Information System (INIS)

    Zakeri, F.; Honarjoo, M.; Rajab pour, M.; Zahadat, A.; Ahmad pour, M.J.; Asghari, K.

    2007-01-01

    Complete text of publication follows. Objective: This study was aimed at detecting both the incidence of chromosomal aberrations and changes in the hematological parameters as biomarkers of possible radiation injury among workers occupationally exposed to low levels of ionizing radiation and detecting the dose-effect relationship. Methods: Samples of peripheral blood were collected from 38 male industrial radiographers exposed to ionizing radiation for 1-16 years and from 24 age- and sex-matched healthy blood donors without radiation history served as control group. All radiation workers were routinely monitored with film badge. Cytogenetic analysis in peripheral blood lymphocytes assessed by the conventional chromosome aberration assay and at least 200 metaphases for each person were scored. The collected blood samples were analyzed for hematological assay using an automatic analyzer Sysmex KX-21, where 14 different parameters were computerized. Mann-Whitney U test was used to compare the frequencies of the unstable aberrations and hematological parameters between test and control groups. Dose-effect relationship and the influence of age and duration of employment was tested by regression analysis. Results and conclusion: The mean frequencies of dicentric and acentric chromosome aberrations were significantly higher in the exposed group than in the control group (P< 0.0005). No correlation between chromosomal aberrations and physical dose and age was observed in the exposed group. Also there is no clear relation between chromosome damage and duration of exposure. However, the increase in chromosome aberrations in the exposed group was not followed by a corresponding hematological depression. The average values of hematological indices were within the reference levels and did not show any significant differences with control group. A tendency of decreasing the absolute lymphocyte count within the referential levels was the only hematological effect in radiation

  7. Some hematological and biochemical parameters in smokeless ...

    African Journals Online (AJOL)

    The effect of Jharda powder (smokeless tobacco) on some hematological and biochemical parameters in consumers was investigated. Hematological parameters including hemoglobin content and white blood cell and leukocyte counts were higher in jharda powder consumers, while monocytes and basophiles counts were ...

  8. Multi-factor analysis on events related to hematological toxicity in 153Sm-EDTMP palliative therapy for skeletal metastases

    International Nuclear Information System (INIS)

    Zhan Hongwei; Yu Xiaoling; Ye Xiaojuan; Bao Chengkan; Sun Da; He Gangqiang

    2006-01-01

    Objective: To investigate the clinical factors related to hematological toxicity induced by intravenous samarium-153 ethylenediaminetetramethylene phosphonic acid ( 153 Sm-EDTMP) treatment. Methods A total of 206 patients with bony metastases treated with 153 Sm-EDTMP were retrospectively analyzed. Logistic regression (SPSS 10.0 for Windows) and correlation analysis were used to evaluate the factors concerned. Results: Age of the patient, number of bone metastatic lesion, chemotherapy before 153 Sm-EDTMP therapy, concurrent radiotherapy and repeat-times of 153 Sm-EDTMP treatments were found the individual factors related to hematological toxicity. Chemotherapy before 153 Sm-EDTMP, concurrent radiotherapy, medication for normal blood counting and repeat-times of 153 Sm-EDTMP treatments were the hematological toxicity factors in multi-factor analysis. Conclusion: In 153 Sm-EDTMP therapy, several factors were found related to hematological toxicity suggesting more attention be paid to the change of blood cell counting after the palliative therapy. (authors)

  9. Influences of oxygen gas flow rate on electrical properties of Ga-doped ZnO thin films deposited on glass and sapphire substrates

    International Nuclear Information System (INIS)

    Makino, Hisao; Song, Huaping; Yamamoto, Tetsuya

    2014-01-01

    The Ga-doped ZnO (GZO) films deposited on glass and c-plane sapphire substrates have been comparatively studied in order to explore the role of grain boundaries in electrical properties. The influences of oxygen gas flow rates (OFRs) during the deposition by ion-plating were examined. The dependences of carrier concentration, lattice parameters, and characteristic of thermal desorption of Zn on the OFR showed common features between glass and sapphire substrates, however, the Hall mobility showed different behavior. The Hall mobility of GZO films on glass increased with increasing OFR of up to 15 sccm, and decreased with further increasing OFR. On the other hand, the Hall mobility of GZO films on c-sapphire increased for up to 25 sccm. The role of grain boundary in polycrystalline GZO films has been discussed. - Highlights: • Ga-doped ZnO films were deposited on glass and c-sapphire by ion-plating. • The epitaxial growth on c-sapphire was confirmed by X-ray diffraction. • Dependence of Hall mobility showed different tendency between glass and sapphire. • Grain boundaries influence transport properties at high O 2 gas flow rate

  10. Description of Project Sapphire. Revision 1

    International Nuclear Information System (INIS)

    Taylor, R.G.

    1995-01-01

    The mission of Project Sapphire was to repackage approximately 600 kg of highly enriched uranium (HEU) in the Republic of Kazakhstan into internationally acceptable shipping packages and transport the material to a storage location in the United States. There were four material types to be repackaged: metal; oxide; uranium/beryllium (U/Be) alloy; and residues from U/Be alloy production. Seven major steps described in this report were necessary for successful execution of the project: planning and training; readiness assessment; deployment; set up; process; take down; and transport. Nuclear criticality safety especially affected several of these steps

  11. 15th Congress of European Hematology Association

    NARCIS (Netherlands)

    Chomienne, Christine; Guenova, Margarita; Hagenbeek, Antony; Lacombe, Catherine; McCann, Shaun; Foa, Robin

    2010-01-01

    Each year the annual congress of the European Hematology Association gathers clinicians, biologists and scientists dedicated to all fields of hematology. This year's Congress was held in Barcelona, Spain, and presented an appealing program with experts presenting state-of-the-art sessions to more

  12. On the laser lift-off of lightly doped micrometer-thick n-GaN films from substrates via the absorption of IR radiation in sapphire

    Energy Technology Data Exchange (ETDEWEB)

    Voronenkov, V. V. [Russian Academy of Sciences, Ioffe Physical–Technical Institute (Russian Federation); Virko, M. V.; Kogotkov, V. S.; Leonidov, A. A. [Peter the Great St. Petersburg Polytechnic University (Russian Federation); Pinchuk, A. V.; Zubrilov, A. S.; Gorbunov, R. I.; Latishev, F. E.; Bochkareva, N. I.; Lelikov, Y. S.; Tarkhin, D. V.; Smirnov, A. N.; Davydov, V. Y. [Russian Academy of Sciences, Ioffe Physical–Technical Institute (Russian Federation); Sheremet, I. A. [Financial University under the Government of the Russian Federation (Russian Federation); Shreter, Y. G., E-mail: y.shreter@mail.ioffe.ru [Russian Academy of Sciences, Ioffe Physical–Technical Institute (Russian Federation)

    2017-01-15

    The intense absorption of CO{sub 2} laser radiation in sapphire is used to separate GaN films from GaN templates on sapphire. Scanning of the sapphire substrate by the laser leads to the thermal dissociation of GaN at the GaN/sapphire interface and to the detachment of GaN films from the sapphire. The threshold density of the laser energy at which n-GaN started to dissociate is 1.6 ± 0.5 J/cm{sup 2}. The mechanical-stress distribution and the surface morphology of GaN films and sapphire substrates before and after laser lift-off are studied by Raman spectroscopy, atomic-force microscopy, and scanning electron microscopy. A vertical Schottky diode with a forward current density of 100 A/cm{sup 2} at a voltage of 2 V and a maximum reverse voltage of 150 V is fabricated on the basis of a 9-μm-thick detached n-GaN film.

  13. Sapphire: a better material for atomization and in situ collection of silver volatile species for atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Musil, Stanislav, E-mail: stanomusil@biomed.cas.cz; Matoušek, Tomáš; Dědina, Jiří

    2015-06-01

    Sapphire is presented as a high temperature and corrosion resistant material of an optical tube of an atomizer for volatile species of Ag generated by the reaction with NaBH{sub 4}. The modular atomizer design was employed which allowed to carry out the measurements in two modes: (i) on-line atomization and (ii) in situ collection (directly in the optical tube) by means of excess of O{sub 2} over H{sub 2} in the carrier gas during the trapping step and vice versa in the volatilization step. In comparison with quartz atomizers, the sapphire tube atomizer provides a significantly increased atomizer lifetime as well as substantially improved repeatability of the Ag in situ collection signals shapes. In situ collection of Ag in the sapphire tube atomizer was highly efficient (> 90%). Limit of detection in the on-line atomization mode and in situ collection mode, respectively, was 1.2 ng ml{sup −1} and 0.15 ng ml{sup −1}. - Highlights: • Sapphire was tested as a new material of an atomizer tube for Ag volatile species. • Two measurement modes were investigated: on-line atomization and in situ collection. • In situ collection of Ag was highly efficient (> 90%) with LOD of 0.15 ng ml{sup −1}. • No devitrification of the sapphire tube observed in the course of several months.

  14. Interfacial thermal resistance between high-density polyethylene (HDPE) and sapphire

    International Nuclear Information System (INIS)

    Zheng Kun; Ma Yong-Mei; Wang Fo-Song; Zhu Jie; Tang Da-Wei

    2014-01-01

    To improve the thermal conductivity of polymeric composites, the numerous interfacial thermal resistance (ITR) inside is usually considered as a bottle neck, but the direct measurement of the ITR is hardly reported. In this paper, a sandwich structure which consists of transducer/high density polyethylene (HDPE)/sapphire is prepared to study the interface characteristics. Then, the ITRs between HDPE and sapphire of two samples with different HDPE thickness values are measured by time-domain thermoreflectance (TDTR) method and the results are ∼ 2 × 10 −7 m 2 ·K·W −1 . Furthermore, a model is used to evaluate the importance of ITR for the thermal conductivity of composites. The model's analysis indicates that reducing the ITR is an effective way of improving the thermal conductivity of composites. These results will provide valuable guidance for the design and manufacture of polymer-based thermally conductive materials. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  15. Wetting behavior of liquid Fe-C-Ti alloys on sapphire

    International Nuclear Information System (INIS)

    Gelbstein, M.; Froumin, N.; Frage, N.

    2008-01-01

    Wetting behavior in the (Fe-C-Ti)/sapphire system was studied at 1823 K. The wetting angle between sapphire and Fe-C alloys is higher than 90 deg. (93 deg. and 105 deg. for the alloys with 1.4 and 3.6 at.% C, respectively). The presence of Ti improves the wetting of the iron-carbon alloys, especially for the alloys with carbon content of 3.6 at.%. The addition of 5 at.% Ti to Fe-3.6 at.% C provides a contact angle of about 30 deg., while the same addition to Fe-1.4 at.% C decreases the wetting angle to 70 deg. only. It was established that the wetting in the systems is controlled by the formation of a titanium oxicarbide layer at the interface, which composition and thickness depend on C and Ti contents in the melt. The experimental observations are well accounted for by a thermodynamic analysis of the Fe-Ti-Al-O-C system

  16. Extracellular Vesicles in Hematological Disorders

    Directory of Open Access Journals (Sweden)

    Anat Aharon

    2014-10-01

    Full Text Available Extracellular vesicles (EVs, comprised of exosomes, microparticles, apoptotic bodies, and other microvesicles, are shed from a variety of cells upon cell activation or apoptosis. EVs promote clot formation, mediate pro-inflammatory processes, transfer proteins and miRNA to cells, and induce cell signaling that regulates cell differentiation, proliferation, migration, invasion, and apoptosis. This paper will review the contribution of EVs in hematological disorders, including hemoglobinopathies (sickle cell disease, thalassemia, paroxysmal nocturnal hemoglobinuria, and hematological malignancies (lymphomas, myelomas, and acute and chronic leukemias.

  17. Neutron reflectivity study of substrate surface chemistry effects on supported phospholipid bilayer formation on (1120) sapphire.

    Energy Technology Data Exchange (ETDEWEB)

    Oleson, Timothy A. [University of Wisconsin, Madison; Sahai, Nita [University of Akron; Wesolowski, David J [ORNL; Dura, Joseph A [ORNL; Majkrzak, Charles F [ORNL; Giuffre, Anthony J. [University of Wisconsin, Madison

    2012-01-01

    Oxide-supported phospholipid bilayers (SPBs) used as biomimetric membranes are significant for a broad range of applications including improvement of biomedical devices and biosensors, and in understanding biomineralization processes and the possible role of mineral surfaces in the evolution of pre-biotic membranes. Continuous-coverage and/or stacjed SPBs retain properties (e.,g. fluidity) more similar to native biological membranes, which is desirable for most applications. Using neutron reflectivity, we examined face coverage and potential stacking of dipalmitoylphosphatidylcholine (DPPC) bilayers on the (1120) face of sapphire (a-Al2O3). Nearly full bilayers were formed at low to neutral pH, when the sapphire surface is positively charged, and at low ionic strength (l=15 mM NaCl). Coverage decreased at higher pH, close to the isoelectric point of sapphire, and also at high I>210mM, or with addition of 2mM Ca2+. The latter two effects are additive, suggesting that Ca2+ mitigates the effect of higher I. These trends agree with previous results for phospholipid adsorption on a-Al2O3 particles determined by adsorption isotherms and on single-crystal (1010) sapphire by atomic force microscopy, suggesting consistency of oxide surface chemistry-dependent effects across experimental techniques.

  18. Formation of Au nanoparticles in sapphire by using Ar ion implantation and thermal annealing

    International Nuclear Information System (INIS)

    Zhou, L.H.; Zhang, C.H.; Yang, Y.T.; Li, B.S.; Zhang, L.Q.; Fu, Y.C.; Zhang, H.H.

    2009-01-01

    In this paper, we present results of the synthesis of gold nanoclusters in sapphire, using Ar ion implantation and annealing in air. Unlike the conventional method of Au implantation followed by thermal annealing, Au was deposited on the surface of m- and a- cut sapphire single crystal samples including those pre-implanted with Ar ions. Au atoms were brought into the substrate by subsequent implantation of Ar ions to form Au nanoparticles. Samples were finally annealed stepwisely in air at temperatures ranging from 400 to 800 deg. C and then studied using UV-vis absorption spectrometry, transmission electron microscopy and Rutherford backscattered spectrometry. Evidence of the formation Au nanoparticles in the sapphire can be obtained from the characteristic surface plasmon resonance (SPR) absorption band in the optical absorption spectra or directly from the transmission electron microscopy. The results of optical absorption spectra indicate that the specimen orientations and pre-implantation also influence the size and the volume fraction of Au nanoparticles formed. Theoretical calculations using Maxwell-Garnett effective medium theory supply a good interpretation of the optical absorption results.

  19. Utility of CRISPR/Cas9 systems in hematology research.

    Science.gov (United States)

    Lucas, Daniel; O'Leary, Heather A; Ebert, Benjamin L; Cowan, Chad A; Tremblay, Cedric S

    2017-10-01

    Since the end of the 20th century, novel approaches have emerged to manipulate experimental models of hematological disorders so that they more accurately mirror what is observed in the clinical setting. Despite these technological advances, the characterization of crucial genes for benign or malignant hematological disorders remains challenging, given the dynamic nature of the hematopoietic system and the genetic heterogeneity of these disorders. To overcome this limitation, genome-editing technologies have been developed to manipulate the genome specifically via deletion, insertion, or modification of targeted loci. These technologies have progressed swiftly, allowing their common use to investigate genetic function in experimental hematology. Among them, homologous-recombination-mediated targeting technologies have facilitated the manipulation of specific loci by generating knock-out and knock-in models. Despite promoting significant advances in our understanding of the molecular mechanisms involved in hematology, these inefficient, time-consuming, and labor-intensive approaches did not permit the development of cellular or animal models, recapitulating the complexity of hematological disorders. On October 26, 2016, Drs. Ben Ebert and Chad Cowan shared their knowledge of and experience with the utilization of CRISPR for models of myeloid malignancy, disease, and novel therapeutics in an International Society for Experimental Hematology webinar titled "Utility of CRISPR/Cas9 Systems in Hematology Research." Here, we provide an overview of the topics they covered, including their insights into the novel applications of the technique and its strengths and limitations. Copyright © 2017 ISEH – Society for Hematology and Stem Cells. Published by Elsevier Inc. All rights reserved.

  20. Hematological abnormalities in adult patients with Down's syndrome.

    LENUS (Irish Health Repository)

    McLean, S

    2012-02-01

    BACKGROUND: There is a paucity of data regarding hematological abnormalities in adults with Down\\'s syndrome (DS). AIMS: We aimed to characterize hematological abnormalities in adult patients with DS and determine their long-term significance. METHODS: We retrospectively studied a cohort of nine DS patients referred to the adult hematology service in our institution between May 2001 and April 2008. Data collected were: full blood count (FBC), comorbidities, investigations performed, duration of follow-up and outcome to most recent follow-up. RESULTS: Median follow-up was 26 months (9-71). Of the nine patients, two had myelodysplastic syndrome (MDS) at presentation. Of these, one progressed, with increasing marrow failure, and requiring support with transfusions and gCSF. The remaining eight patients, with a variety of hematological abnormalities including leukopenia, macrocytosis, and thrombocytopenia, had persistently abnormal FBCs. However there was no evidence of progression, and no patient has evolved to acute myeloid leukemia (AML). CONCLUSIONS: MDS is a complication of DS and may require supportive therapy. However, minor hematological abnormalities are common in adult DS patients, and may not signify underlying marrow disease.

  1. Patterning of light-extraction nanostructures on sapphire substrates using nanoimprint and ICP etching with different masking materials.

    Science.gov (United States)

    Chen, Hao; Zhang, Qi; Chou, Stephen Y

    2015-02-27

    Sapphire nanopatterning is the key solution to GaN light emitting diode (LED) light extraction. One challenge is to etch deep nanostructures with a vertical sidewall in sapphire. Here, we report a study of the effects of two masking materials (SiO2 and Cr) and different etching recipes (the reaction gas ratio, the reaction pressure and the inductive power) in a chlorine-based (BCl3 and Cl2) inductively coupled plasma (ICP) etching of deep nanopillars in sapphire, and the etching process optimization. The masking materials were patterned by nanoimprinting. We have achieved high aspect ratio sapphire nanopillar arrays with a much steeper sidewall than the previous etching methods. We discover that the SiO2 mask has much slower erosion rate than the Cr mask under the same etching condition, leading to the deep cylinder-shaped nanopillars (122 nm diameter, 200 nm pitch, 170 nm high, flat top, and a vertical sidewall of 80° angle), rather than the pyramid-shaped shallow pillars (200 nm based diameter, 52 nm height, and 42° sidewall) resulted by using Cr mask. The processes developed are scalable to large volume LED manufacturing.

  2. Complementary and Alternative Medicine: A Clinical Study in 1,016 Hematology/Oncology Patients.

    Science.gov (United States)

    Hierl, Marina; Pfirstinger, Jochen; Andreesen, Reinhard; Holler, Ernst; Mayer, Stephanie; Wolff, Daniel; Vogelhuber, Martin

    2017-01-01

    Surveys state a widespread use of complementary and alternative medicine (CAM) in patients with malignant diseases. CAM methods might potentially interfere with the metabolization of tumor-specific therapy. However, there is little communication about CAM use in hematology/oncology patients between patients, CAM providers, and oncologists. A self-administered questionnaire was handed out to all patients attending to the hematology/oncology outpatient clinic of Regensburg University Hospital. Subsequently, a chart review of all CAM users was performed. Questionnaires of 1,016 patients were analyzed. Of these patients, 30% used CAM, preferably vitamins and micronutrients. Main information sources for CAM methods were physicians/nonmedical practitioners and friends/relatives. CAM therapies were provided mainly by licensed physicians (29%), followed by nonmedical practitioners (14%) and the patients themselves (13%). Although 62% of the CAM users agreed that the oncologist may know about their CAM therapy, a chart entry about CAM use was found only in 41%. CAM is frequently used by hematology/oncology patients. Systematic communication about CAM is essential to avoid possible drug interactions. © 2017 S. Karger AG, Basel.

  3. Sub-100 fs high average power directly blue-diode-laser-pumped Ti:sapphire oscillator

    Science.gov (United States)

    Rohrbacher, Andreas; Markovic, Vesna; Pallmann, Wolfgang; Resan, Bojan

    2016-03-01

    Ti:sapphire oscillators are a proven technology to generate sub-100 fs (even sub-10 fs) pulses in the near infrared and are widely used in many high impact scientific fields. However, the need for a bulky, expensive and complex pump source, typically a frequency-doubled multi-watt neodymium or optically pumped semiconductor laser, represents the main obstacle to more widespread use. The recent development of blue diodes emitting over 1 W has opened up the possibility of directly diode-laser-pumped Ti:sapphire oscillators. Beside the lower cost and footprint, a direct diode pumping provides better reliability, higher efficiency and better pointing stability to name a few. The challenges that it poses are lower absorption of Ti:sapphire at available diode wavelengths and lower brightness compared to typical green pump lasers. For practical applications such as bio-medicine and nano-structuring, output powers in excess of 100 mW and sub-100 fs pulses are required. In this paper, we demonstrate a high average power directly blue-diode-laser-pumped Ti:sapphire oscillator without active cooling. The SESAM modelocking ensures reliable self-starting and robust operation. We will present two configurations emitting 460 mW in 82 fs pulses and 350 mW in 65 fs pulses, both operating at 92 MHz. The maximum obtained pulse energy reaches 5 nJ. A double-sided pumping scheme with two high power blue diode lasers was used for the output power scaling. The cavity design and the experimental results will be discussed in more details.

  4. Generation of continuous-wave single-frequency 1.5 W 378 nm radiation by frequency doubling of a Ti:sapphire laser.

    Science.gov (United States)

    Cha, Yong-Ho; Ko, Kwang-Hoon; Lim, Gwon; Han, Jae-Min; Park, Hyun-Min; Kim, Taek-Soo; Jeong, Do-Young

    2010-03-20

    We have generated continuous-wave single-frequency 1.5 W 378 nm radiation by frequency doubling a high-power Ti:sapphire laser in an external enhancement cavity. An LBO crystal that is Brewster-cut and antireflection coated on both ends is used for a long-term stable frequency doubling. By optimizing the input coupler's reflectivity, we could generate 1.5 W 378 nm radiation from a 5 W 756 nm Ti:sapphire laser. According to our knowledge, this is the highest CW frequency-doubled power of a Ti:sapphire laser.

  5. Lattice dynamics of sapphire (corundum). Pt. 2

    International Nuclear Information System (INIS)

    Kappus, W.

    1975-01-01

    Theoretical models of the lattice dynamics of sapphire (α - Al 2 O 3 ), based on the assumption of rigid ions, have been fitted to measured phonons at the Gamma-point of the Brillouin zone. Short range interactions were taken into account by assuming 2-body interactions between touching ions. Additional 3-body interactions could not improve the fit significantly. Calculated dispersion curves are presented and compared with inelastic neutron scattering data. A good agreement for branches along the trigonal axis can be stated. (orig.) [de

  6. Characterization of local hydrophobicity on sapphire (0001) surfaces in aqueous environment by colloidal probe atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wada, Tomoya; Yamazaki, Kenji; Isono, Toshinari; Ogino, Toshio, E-mail: ogino-toshio-rx@ynu.ac.jp

    2017-02-28

    Highlights: • Local hydrophobicity of phase-separated sapphire (0001) surfaces was investigated. • These surfaces are featured by coexistence of hydrophilic and hydrophobic domains. • Each domain was characterized by colloidal probe atomic force microscopy in water. • Both domains can be distinguished by adhesive forces of the probe to the surfaces. • Characterization in aqueous environment is important in bio-applications of sapphire. - Abstract: Sapphire (0001) surfaces exhibit a phase-separation into hydrophobic and hydrophilic domains upon high-temperature annealing, which were previously distinguished by the thickness of adsorbed water layers in air using atomic force microscopy (AFM). To characterize their local surface hydrophobicity in aqueous environment, we used AFM equipped with a colloidal probe and measured the local adhesive force between each sapphire domain and a hydrophilic SiO{sub 2} probe surface, or a hydrophobic polystyrene one. Two data acquisition modes for statistical analyses were used: one is force measurements at different positions of the surface and the other repeated measurement at a fixed position. We found that adhesive force measurements using the polystyrene probe allow us to distinctly separate the hydrophilic and hydrophobic domains. The dispersion in the force measurement data at different positions of the surface is larger than that in the repeated measurements at a fixed position. It indicates that the adhesive force measurement is repeatable although their data dispersion for the measurement positions is relatively large. From these results, we can conclude that the hydrophilic and hydrophobic domains on the sapphire (0001) surfaces are distinguished by a difference in their hydration degrees.

  7. Interfacial structure of V2AlC thin films deposited on (112-bar 0)-sapphire

    International Nuclear Information System (INIS)

    Sigumonrong, Darwin P.; Zhang, Jie; Zhou, Yanchun; Music, Denis; Emmerlich, Jens; Mayer, Joachim; Schneider, Jochen M.

    2011-01-01

    Local epitaxy between V 2 AlC and sapphire without intentionally or spontaneously formed seed layers was observed by transmission electron microscopy. Our ab initio calculations suggest that the most stable interfacial structure is characterized by the stacking sequence ...C-V-Al-V//O-Al..., exhibiting the largest work of separation for the configurations studied and hence strong interfacial bonding. It is proposed that a small misfit accompanied by strong interfacial bonding enable the local epitaxial growth of V 2 AlC on (112-bar 0)-sapphire.

  8. Radiation hematology

    International Nuclear Information System (INIS)

    Zherbin, E.A.; Chukhlovin, A.B.

    1989-01-01

    State-of-the-Art ofl radiation hematology and review of the problems now facing this brauch of radiobiology and nuclear medicine are presented. Distortion of division and maturation of hemopoiesis parent cells is considered as main factor of radiopathology for hematopoetic system. Problems of radiation injury and functional variation of hematopoetic microenvironment cell populations are discussed. 176 figs.; 23 figs.; 18 tabs

  9. Microscopic origin of the optical processes in blue sapphire.

    Science.gov (United States)

    Bristow, Jessica K; Parker, Stephen C; Catlow, C Richard A; Woodley, Scott M; Walsh, Aron

    2013-06-11

    Al2O3 changes from transparent to a range of intense colours depending on the chemical impurities present. In blue sapphire, Fe and Ti are incorporated; however, the chemical process that gives rise to the colour has long been debated. Atomistic modelling identifies charge transfer from Ti(III) to Fe(III) as being responsible for the characteristic blue appearance.

  10. Microscopic origin of the optical processes in blue sapphire

    OpenAIRE

    Bristow, JK; Parker, SC; Catlow, CRA; Woodley, SM; Walsh, A

    2013-01-01

    Al2O3 changes from transparent to a range of intense colours depending on the chemical impurities present. In blue sapphire, Fe and Ti are incorporated; however, the chemical process that gives rise to the colour has long been debated. Atomistic modelling identifies charge transfer from Ti(III) to Fe(III) as being responsible for the characteristic blue appearance.

  11. Striking hematological abnormalities in patients with microcephalic osteodysplastic primordial dwarfism type II (MOPD II): a potential role of pericentrin in hematopoiesis.

    Science.gov (United States)

    Unal, Sule; Alanay, Yasemin; Cetin, Mualla; Boduroglu, Koray; Utine, Eda; Cormier-Daire, Valerie; Huber, Celine; Ozsurekci, Yasemin; Kilic, Esra; Simsek Kiper, Ozlem Pelin; Gumruk, Fatma

    2014-02-01

    Microcephalic osteodysplastic primordial dwarfism type II (MOPD II) is a rare primordial dwarfism that is similar to Seckel syndrome. Seckel syndrome is known to be associated with various hematological abnormalities; however, hematological findings in MOPD II patients have not been previously reported. The present study aimed to describe the hematological findings in a series of eight patients with MOPD II from a single center. The study included eight patients with MOPD II that were analyzed via molecular testing, and physical and laboratory examinations. Molecular testing showed that seven of the eight patients had pericentrin (PCNT) gene mutations. Hematological evaluation showed that 7 (87.5%) patients had thrombocytosis, 6 (75%) had leukocytosis, 5 (62.5%) had both leukocytosis and thrombocytosis, and 2 (25%) had anemia. We report leukocytosis and thrombocytosis as a common hematologic abnormality in patients with MOPD II. The present findings may improve our understanding of the potential function of the PCNT gene in hematopoietic cell proliferation and differentiation. © 2013 Wiley Periodicals, Inc.

  12. Characteristics of InGaN-Based Light-Emitting Diodes on Patterned Sapphire Substrates with Various Pattern Heights

    Directory of Open Access Journals (Sweden)

    Sheng-Fu Yu

    2012-01-01

    Full Text Available The optical and electrical characteristics of InGaN-based blue light-emitting diodes (LEDs grown on patterned sapphire substrates (PSSs with different pattern heights and on planar sapphire by atmospheric-pressure metal-organic chemical vapor deposition were investigated. Compared with planar sapphire, it was found that the LED electroluminescence intensity is significantly enhanced on PSSs with pattern heights of 0.5 (21%, 1.1 (57%, 1.5 (81%, and 1.9 (91% μm at an injected current of 20 mA. The increased light intensity exhibits the same trend in a TracePro simulation. In addition, it was also found that the level of leakage current depends on the density of V-shape defects, which were measured by scanning electron microscopy.

  13. Sapphire/TiAl composites - structure and properties

    International Nuclear Information System (INIS)

    Povarova, K.B.; Antonova, A.V.; Mileiko, S.T.; Sarkissyan, N.S.

    2001-01-01

    Ti-Al-intermetallic-based alloys with lamellar microstructure, -γ(TiAl) +α 2 (Ti 3 Al) are characterized by a high melting point of 1460 o C, a low density of ∼3.9 g/cm 3 , a high gas corrosion resistance up to a temperature of about 900 o C, a high creep resistance up to a temperature of about 800 o C, and a sufficiently high fracture toughness at low temperatures, up to 30 Mpa x m 1/2 . Hence, they are considered as excellent matrices for fibres of high melting point. Unlike well-developed SiC/TiAl composites, which have an obvious upper limit for the usage temperature due to SiC/TiAl interaction, Sapphire/TiAl composites remain nearly unknown because fibres to be used in such composites have not been really available. At the present time, such fibres are developed in Solid State Physics Inst. of RAS. The results of preliminary creep tests of Al 2 O 3 /TiAl composites obtained by using pressure casting have shown that usage of such composite systems shifts the temperature limit for light structural materials in terms of creep resistance to, at least, 1050 o C: creep strength on 100 h time base reaches 120 MPa at that temperature. It occurs also that Sapphire-fibres/TiAl-matrix composite specimens have an increased gas corrosion resistance by more than one order of the magnitudes as compared with that of the matrix alloy. (author)

  14. Synthesis of titanium sapphire by ion implantation

    International Nuclear Information System (INIS)

    Morpeth, L.D.; McCallum, J.C.; Nugent, K.W.

    1998-01-01

    Since laser action was first demonstrated in titanium sapphire (Ti:Al 2 O 3 ) in 1982, it has become the most widely used tunable solid state laser source. The development of a titanium sapphire laser in a waveguide geometry would yield an elegant, compact, versatile and highly tunable light source useful for applications in many areas including optical telecommunications. We are investigating whether ion implantation techniques can be utilised to produce suitable crystal quality and waveguide geometry for fabrication of a Ti:Al 2 O 3 waveguide laser. The implantation of Ti and O ions into c-axis oriented α-Al 2 O 3 followed by subsequent thermal annealing under various conditions has been investigated as a means of forming the waveguide and optimising the fraction of Ti ions that have the correct oxidation state required for laser operation. A Raman Microprobe is being used to investigate the photo-luminescence associated with Ti 3+ ion. Initial photoluminescence measurements of ion implanted samples are encouraging and reveal a broad luminescence profile over a range of ∼ .6 to .9 μm, similar to that expected from Ti 3+ . Rutherford Backscattering and Ion Channelling analysis have been used to study the crystal structure of the samples following implantation and annealing. This enables optimisation of the implantation parameters and annealing conditions to minimise defect levels which would otherwise limit the ability of light to propagate in the Ti:Al 2O 3 waveguide. (authors)

  15. A risk prediction score for invasive mold disease in patients with hematological malignancies.

    Directory of Open Access Journals (Sweden)

    Marta Stanzani

    Full Text Available BACKGROUND: A risk score for invasive mold disease (IMD in patients with hematological malignancies could facilitate patient screening and improve the targeted use of antifungal prophylaxis. METHODS: We retrospectively analyzed 1,709 hospital admissions of 840 patients with hematological malignancies (2005-2008 to collect data on 17 epidemiological and treatment-related risk factors for IMD. Multivariate regression was used to develop a weighted risk score based on independent risk factors associated with proven or probable IMD, which was prospectively validated during 1,746 hospital admissions of 855 patients from 2009-2012. RESULTS: Of the 17 candidate variables analyzed, 11 correlated with IMD by univariate analysis, but only 4 risk factors (neutropenia, lymphocytopenia or lymphocyte dysfunction in allogeneic hematopoietic stem cell transplant recipients, malignancy status, and prior IMD were retained in the final multivariate model, resulting in a weighted risk score 0-13. A risk score of 5% of IMD, with a negative predictive value (NPV of 0.99, (95% CI 0.98-0.99. During 2009-2012, patients with a calculated risk score at admission of 6 (0.9% vs. 10.6%, P <0.001. CONCLUSION: An objective, weighted risk score for IMD can accurately discriminate patients with hematological malignancies at low risk for developing mold disease, and could possibly facilitate "screening-out" of low risk patients less likely to benefit from intensive diagnostic monitoring or mold-directed antifungal prophylaxis.

  16. Dependence of adhesion strength between GaN LEDs and sapphire substrate on power density of UV laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Junsu [Department of Nano-Manufacturing Technology, Korea Institute of Machinery and Materials, 156 Gajeongbuk-Ro, Yuseong-Gu, Daejeon 34103 (Korea, Republic of); Sin, Young-Gwan [Department of Nano-Mechatronics, Korea University of Science and Technology (UST), 217 Gajeong-Ro, Yuseong-Gu, Daejeon 34113 (Korea, Republic of); Kim, Jae-Hyun [Department of Nano-Mechanics, Korea Institute of Machinery and Materials, 156 Gajeongbuk-Ro, Yuseong-Gu, Daejeon 34103 (Korea, Republic of); Kim, Jaegu, E-mail: gugu99@kimm.re.kr [Department of Nano-Manufacturing Technology, Korea Institute of Machinery and Materials, 156 Gajeongbuk-Ro, Yuseong-Gu, Daejeon 34103 (Korea, Republic of)

    2016-10-30

    Highlights: • Fundamental relationship between laser irradiation and adhesion strength, between gallium-nitride light emitted diode and sapphire substrate, is proposed during selective laser lift-off. • Two competing mechanisms affect adhesion at the irradiated interface between the GaN LED and sapphire substrate. • Ga precipitation caused by thermal decomposition and roughened interface caused by thermal damage lead to the considerable difference of adhesion strength at the interface. - Abstract: Selective laser lift-off (SLLO) is an innovative technology used to manufacture and repair micro-light-emitting diode (LED) displays. In SLLO, laser is irradiated to selectively separate micro-LED devices from a transparent sapphire substrate. The light source used is an ultraviolet (UV) laser with a wavelength of 266 nm, pulse duration of 20 ns, and repetition rate of 30 kHz. Controlled adhesion between a LED and the substrate is key for a SLLO process with high yield and reliability. This study examined the fundamental relationship between adhesion and laser irradiation. Two competing mechanisms affect adhesion at the irradiated interface between the GaN LED and sapphire substrate: Ga precipitation caused by the thermal decomposition of GaN and roughened interface caused by thermal damage on the sapphire. The competition between these two mechanisms leads to a non-trivial SLLO condition that needs optimization. This study helps understand the SLLO process, and accelerate the development of a process for manufacturing micro-LED displays via SLLO for future applications.

  17. Vanadium-rich ruby and sapphire within Mogok Gemfield, Myanmar: implications for gem color and genesis

    Science.gov (United States)

    Zaw, Khin; Sutherland, Lin; Yui, Tzen-Fu; Meffre, Sebastien; Thu, Kyaw

    2015-01-01

    Rubies and sapphires are of both scientific and commercial interest. These gemstones are corundum colored by transition elements within the alumina crystal lattice: Cr3+ yields red in ruby and Fe2+, Fe3+, and Ti4+ ionic interactions color sapphires. A minor ion, V3+ induces slate to purple colors and color change in some sapphires, but its role in coloring rubies remains enigmatic. Trace element and oxygen isotope composition provide genetic signatures for natural corundum and assist geographic typing. Here, we show that V can dominate chromophore contents in Mogok ruby suites. This raises implications for their color quality, enhancement treatments, geographic origin, exploration and exploitation and their comparison with rubies elsewhere. Precise LA-ICP-MS analysis of ruby and sapphire from Mogok placer and in situ deposits reveal that V can exceed 5,000 ppm, giving V/Cr, V/Fe and V/Ti ratios up to 26, 78, and 97 respectively. Such values significantly exceed those found elsewhere suggesting a localized geological control on V-rich ruby distribution. Our results demonstrate that detailed geochemical studies of ruby suites reveal that V is a potential ruby tracer, encourage comparisons of V/Cr-variation between ruby suites and widen the scope for geographic typing and genesis of ruby. This will allow more precise comparison of Asian and other ruby fields and assist confirmation of Mogok sources for rubies in historical and contemporary gems and jewelry.

  18. Hematological parameters after acute radiation injury

    International Nuclear Information System (INIS)

    Hirashima, Kunitake

    1989-01-01

    According to clinical experiences of radiation accidents during the past two decades, utilization of measured hematologic changes as a direcrt indicator of the severity of radiation injury provides important information for diagnosis and prognostic evaluation in individual cases. Hematologic changes can be described in terms of prognostic categories based on the possible outcome of the acute radiation syndrome. The five categories suggested by Wald according to the grade of severity. By the actual application of this category to our experience of the 1971 Chiba accident of exposure to irridium 192, it was proved that the estimated dose was well correlated to the value by cytogenetic analysis and physical estimation used of thermo-luminescence phenomena. In hematological parameters, a decrease of lymphocytes occurs whithin 24 hours after the exposure. The level of this early lymphopenia is regarded as one of the best indicators of severity of radiation injury. For the decision of therapeutic procedures, however, the total granulocyte count and platelet count are more valuable to exclude severe infection and bleeding symptoms occurred one month after the exposure. The limitation of the approach by hematologic data must exist in the case exposed in a non-uniform fashion. To overwhelm this difficulty, the application of rapid marrow scanning by short-lived RI such as 52 Fe is expected and the bone marrow imaging by magnetic resonance studies is more exciting. For more sensitive and technically easy-drived methods detecting hematologic injury, our new method of detecting micro-nucleus in polychromatic erythroblasts from cultured erythroid colonies from peripheral blood is now developing. Preliminary data have shown the sensitivity of this method is comparable to the cytogenetic study of pheripheral lymphocytes. (author)

  19. Structure of the Dislocation in Sapphire

    DEFF Research Database (Denmark)

    Bilde-Sørensen, Jørgen; Thölen, A. R.; Gooch, D. J.

    1976-01-01

    Experimental evidence of the existence of 01 0 dislocations in the {2 0} prism planes in sapphire has been obtained by transmission electron microscopy. By the weak-beam technique it has been shown that the 01 0 dislocations may dissociate into three partials. The partials all have a Burgers vector...... of ⅓ 01 0 and are separated by two identical faults. The distance between two partials is in the range 75-135 Å, corresponding to a fault energy of 320±60 mJ/m2. Perfect 01 0 dislocations have also been observed. These dislocations exhibited either one or two peaks when imaged in the (03 0) reflection...

  20. Detection of solar neutrinos with a torsion balance with sapphire crystal

    Science.gov (United States)

    Cruceru, M.; Nicolescu, G.

    2018-01-01

    The solar neutrinos (antineutrinos) are detected with a dedicated torsion balance in the case when they interact coherently on stiff crystals (sapphire with high Debye temperature ∼1000K and lead with ∼100K Debye temperature). The balance consists in two equal masses of lead and sapphire, of 25g. An autocollimator coupled to this balance measures small rotation angles of the balance. The force with which neutrino flux interacts with these crystals is between 10-5 dyn and 10-8 dyn, comparable with that reported in Weber’s experiments [1]. A diurnal effect is observed for solar neutrinos due to the rotation of the Earth around its own axes. The solar neutrino flux obtained at the site of our experiment is ∼3.8*1010neutrinos/cm2*s [2]. Experimental data for neutrinos signals from this high sensitivity torsion balance are presented and commented [3].

  1. Ga2O3-In2O3 thin films on sapphire substrates: Synthesis and ultraviolet photoconductivity

    Science.gov (United States)

    Muslimov, A. E.; Butashin, A. V.; Kolymagin, A. B.; Nabatov, B. V.; Kanevsky, V. M.

    2017-11-01

    The structure and electrical and optical properties of β-Ga2O3-In2O3 thin films on sapphire substrates with different orientations have been investigated. The samples have been prepared by annealing of gallium-indium metallic films on sapphire substrates in air at different gallium-to-indium ratios in the initial mixture. The photoconductivity of these structures in the solar-blind ultraviolet spectral region has been examined.

  2. Fertility considerations in young women with hematological malignancies

    DEFF Research Database (Denmark)

    Jadoul, Pascale; Kim, S Samuel; Andersen, Claus Yding

    2012-01-01

    The need for practice guidelines for fertility preservation in young women with hematological malignancies has been increased. To develop recommendations, publications relevant to fertility preservation and hematological cancers were identified through a PubMed database search and reviewed...

  3. Characterization and growth mechanism of nonpolar and semipolar GaN layers grown on patterned sapphire substrates

    International Nuclear Information System (INIS)

    Okada, Narihito; Tadatomo, Kazuyuki

    2012-01-01

    Nonpolar and semipolar GaN layers with markedly improved crystalline quality can be obtained by selective-area growth from the sapphire sidewalls of patterned sapphire substrates (PSSs). In this paper, we review the crystalline qualities of GaN layers grown on PSSs and their growth mechanism. We grew semipolar {1 1 −2 2} and {1 0 −1 1} GaN layers on r- and n-PSSs. The crystalline qualities of the GaN layers grown on the PSSs were higher than those of GaN layers grown directly on heteroepitaxial substrates. To reveal the growth mechanism of GaN layers grown on PSSs, we also grew various nonpolar and semipolar GaN layers such as m-GaN on a-PSS, {1 1 −2 2} GaN on r-PSS, {1 0 − 1  1} GaN on n-PSS, m-GaN on c-PSS and a-GaN on m-PSS. It was found that the nucleation of GaN on the c-plane-like sapphire sidewall results in selective growth from the sapphire sidewall, and nonpolar or semipolar GaN can be obtained. Finally, we demonstrated a light-emitting diode fabricated on a {1 1 −2 2} GaN layer grown on an r-PSS. (paper)

  4. Distinct crystallinity and orientations of hydroxyapatite thin films deposited on C- and A-plane sapphire substrates

    Science.gov (United States)

    Akazawa, Housei; Ueno, Yuko

    2014-10-01

    We report how the crystallinity and orientation of hydroxyapatite (HAp) films deposited on sapphire substrates depend on the crystallographic planes. Both solid-phase crystallization of amorphous HAp films and crystallization during sputter deposition at elevated temperatures were examined. The low-temperature epitaxial phase on C-plane sapphire substrates has c-axis orientated HAp crystals regardless of the crystallization route, whereas the preferred orientation switches to the (310) direction at higher temperatures. Only the symmetric stretching mode (ν1) of PO43- units appears in the Raman scattering spectra, confirming well-ordered crystalline domains. In contrast, HAp crystals grown on A-plane sapphire substrates are always oriented toward random orientations. Exhibiting all vibrational modes (ν1, ν3, and ν4) of PO43- units in the Raman scattering spectra reflects random orientation, violating the Raman selection rule. If we assume that Raman intensities of PO43- units represent the crystallinity of HAp films, crystallization terminating the surface with the C-plane is hindered by the presence of excess H2O and OH species in the film, whereas crystallization at random orientations on the A-plane sapphire is rather promoted by these species. Such contrasting behaviors between C-plane and A-plane substrates will reflect surface-plane dependent creation of crystalline seeds and eventually determine the orientation of resulting HAp films.

  5. Report on the International Society for Laboratory Hematology Survey on guidelines to support clinical hematology laboratory practice.

    Science.gov (United States)

    Hayward, C P M; Moffat, K A; George, T I; Proytcheva, M; Iorio, A

    2016-05-01

    Given the importance of evidence-based guidelines in health care, we surveyed the laboratory hematology community to determine their opinions on guideline development and their experience and interest in developing clinical hematology laboratory practice guidelines. The study was conducted using an online survey, distributed to members of the International Society for Laboratory Hematology (ISLH) in 2015, with analysis of collected, anonymized responses. A total of 245 individuals participated. Most worked in clinical and/or research laboratories (83%) or industry (11%). 42% felt there were gaps in current guidelines. The majority (58%) recommended that ISLH engages its membership in guideline development. Participants differed in their familiarity with, and use of, different organizations' guidelines. Participants felt it was important to follow best practice recommendations on guideline development, including engagement of experts, statement about conflict of interests and how they were managed, systematic review and grading evidence for recommendations, identifying recommendations lacking evidence or consensus, and public input and peer review of the guideline. Moreover, it was considered important to provide guidelines free of charge. Industry involvement in guidelines was considered less important. The clinical laboratory hematology community has high expectations of laboratory practice guidelines that are consistent with recent recommendations on evidence-based guideline development. © 2016 John Wiley & Sons Ltd.

  6. Effect of Ti:sapphire laser on shear bond strength of orthodontic brackets to ceramic surfaces.

    Science.gov (United States)

    Erdur, Emire Aybuke; Basciftci, Faruk Ayhan

    2015-08-01

    With increasing demand for orthodontic treatments in adults, orthodontists continue to debate the optimal way to prepare ceramic surfaces for bonding. This study evaluated the effects of a Ti:sapphire laser on the shear bond strength (SBS) of orthodontic brackets bonded to two ceramic surfaces (feldspathic and IPS Empress e-Max) and the results were compared with those using two other lasers (Er:YAG and Nd:YAG) and 'conventional' techniques, i.e., sandblasting (50 µm) and hydrofluoric (HF) acid. In total, 150 ceramic discs were prepared and divided into two groups. In each group, the following five subgroups were prepared: Ti:sapphire laser, Nd:YAG laser, Er:YAG laser, sandblasting, and HF acid. Mandibular incisor brackets were bonded using a light-cured adhesive. The samples were stored in distilled water for 24 hours at 37°C and then thermocycled. Extra samples were prepared and examined using scanning electron microscopy (SEM). SBS testing was performed and failure modes were classified. ANOVA and Tukey's HSD tests were used to compare SBS among the five subgroups (P < 0.05). Feldspathic and IPS Empress e-Max ceramics had similar SBS values. The Ti:sapphire femtosecond laser (16.76 ± 1.37 MPa) produced the highest mean bond strength, followed by sandblasting (12.79 ± 1.42 MPa) and HF acid (11.28 ± 1.26 MPa). The Er:YAG (5.43 ± 1.21 MPa) and Nd:YAG laser (5.36 ± 1.04 MPa) groups were similar and had the lowest SBS values. More homogeneous and regular surfaces were observed in the ablation pattern with the Ti:sapphire laser than with the other treatments by SEM analysis. Within the limitations of this in vitro study, Ti:sapphire laser- treated surfaces had the highest SBS values. Therefore, this technique may be useful for the pretreatment of ceramic surfaces as an alternative to 'conventional' techniques. © 2015 Wiley Periodicals, Inc.

  7. Hematology laboratory standardization: a plan for harmonization in Asia.

    Science.gov (United States)

    Bunyaratvej, A; Tatsumi, N; Funahara, Y

    1999-01-01

    Hematology laboratory is generally required in the hospital. At the macroscale, hematology laboratories have served a large number of population. In Asia, more than 3,000 million people are potentially to use the hematology laboratory service, particularly the complete blood count. Since 1970s, automated technology has been introduced to Asia and as years passed by, technology diversity is increasing. However, there are considerable number of hematology laboratories that have no automated machine. They are still relied on manual technology which is still variable in spectrophotometer for hemoglobin determination, centrifuge for hematocrit and diluting pipet for cell counting. In particular, blood smear preparation and interpretation are very difficult to control for standardization from person to person and laboratory to laboratory. Different methodology and a large population in the huge geographical area in Asia, the agreement of standard criteria is greatly important. This report has shown strategy and action plan to reach the goal of hematology laboratory standardization in Asia.

  8. Defect formation and recrystallization in the silicon on sapphire films under Si{sup +} irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shemukhin, A.A., E-mail: shemuhin@gmail.com [Skobeltsyn Institute of Nuclear Physics, Lomonosov Moscow State University, Moscow (Russian Federation); Nazarov, A.V.; Balakshin, Yu. V. [Skobeltsyn Institute of Nuclear Physics, Lomonosov Moscow State University, Moscow (Russian Federation); Chernysh, V.S. [Skobeltsyn Institute of Nuclear Physics, Lomonosov Moscow State University, Moscow (Russian Federation); Faculty of Physics, Lomonosov Moscow State University, Moscow (Russian Federation)

    2015-07-01

    Silicon-on-sapphire (SOS) is one of the most promising silicon-on-insulator (SOI) technologies. SOS structures are widely used in microelectronics, but to meet modern requirements the silicon layer should be 100 nm thick or less. The problem is in amount of damage in the interface layer, which decreases the quality of the produced devices. In order to improve the crystalline structure quality SOS samples with 300 nm silicon layers were implanted with Si{sup +} ions with energies in the range from 180 up to 230 keV with fluences in the range from 10{sup 14} up to 5 × 10{sup 15} cm{sup −2} at 0 °C. The crystalline structure of the samples was studied with RBS and the interface layer was studied with SIMS after subsequent annealing. It has been found out that to obtain silicon films with high lattice quality it is necessary to damage the sapphire lattice near the silicon–sapphire interface. Complete destruction of the strongly defected area and subsequent recrystallization depends on the energy of implanted ions and the substrate temperature. No significant mixing in the interface layer was observed with the SIMS.

  9. Development of Cr,Nd:GSGG laser as a pumping source of Ti:sapphire laser

    International Nuclear Information System (INIS)

    Tamura, Koji; Arisawa, Takashi

    1999-08-01

    Since efficiency of Cr,Nd doped gadolinium scandium gallium garnet (GSGG) laser is in principle higher than that of Nd:YAG laser, it can be a highly efficient pumping source for Ti:sapphire laser. We have made GSGG laser, and measured its oscillation properties. It was two times more efficient than Nd:YAG laser at free running mode operation. At Q-switched mode operation, fundamental output of 50 mJ and second harmonics output of 8 mJ were obtained. The developed laser had appropriate spatial profile, temporal duration, long time stability for solid laser pumping. Ti:sapphire laser oscillation was achieved by the second harmonics of GSGG laser. (author)

  10. A Review on hematology and hemoglobin of fish

    Directory of Open Access Journals (Sweden)

    Ebru YILMAZ

    2015-01-01

    Full Text Available Determination of hematological parameters of fish living in natüre helps to recognize population and to determinate of pollutants in the aquatic environment. In this review, hematological parameters of fish, fish hemoglobin and the Bohr effect were given information.

  11. Characterization of sapphire: For its material properties at high temperatures

    Science.gov (United States)

    Bal, Harman Singh

    There are numerous needs for sensing, one of which is in pressure sensing for high temperature application such as combustion related process and embedded in aircraft wings for reusable space vehicles. Currently, silicon based MEMS technology is used for pressure sensing. However, due to material properties the sensors have a limited range of approximately 600 °C which is capable of being pushed towards 1000 °C with active cooling. This can introduce reliability issues when you add more parts and high flow rates to remove large amounts of heat. To overcome this challenge, sapphire is investigated for optical based pressure transducers at temperatures approaching 1400 °C. Due to its hardness and chemical inertness, traditional cutting and etching methods used in MEMS technology are not applicable. A method that is being investigated as a possible alternative is laser machining using a picosecond laser. In this research, we study the material property changes that occur from laser machining and quantify the changes with the experimental results obtained by testing sapphire at high-temperature with a standard 4-point bending set-up.

  12. Ultrafast third-harmonic generation from textured aluminum nitride-sapphire interfaces

    International Nuclear Information System (INIS)

    Stoker, D. S.; Keto, J. W.; Baek, J.; Wang, W.; Becker, M. F.; Kovar, D.

    2006-01-01

    We measured and modeled third-harmonic generation (THG) from an AlN thin film on sapphire using a time-domain approach appropriate for ultrafast lasers. Second-harmonic measurements indicated that polycrystalline AlN contains long-range crystal texture. An interface model for third-harmonic generation enabled an analytical representation of scanning THG (z-scan) experiments. Using it and accounting for Fresnel reflections, we measured the AlN-sapphire susceptibility ratio and estimated the susceptibility for aluminum nitride, χ xxxx (3) (3ω;ω,ω,ω)=1.52±0.25x10 -13 esu. The third-harmonic (TH) spectrum strongly depended on the laser focus position and sample thickness. The amplitude and phase of the frequency-domain interference were fit to the Fourier transform of the calculated time-domain field to improve the accuracy of several experimental parameters. We verified that the model works well for explaining TH signal amplitudes and spectral phase. Some anomalous features in the TH spectrum were observed, which we attributed to nonparaxial effects

  13. Value of innovation in hematologic malignancies: a systematic review of published cost-effectiveness analyses.

    Science.gov (United States)

    Saret, Cayla J; Winn, Aaron N; Shah, Gunjan; Parsons, Susan K; Lin, Pei-Jung; Cohen, Joshua T; Neumann, Peter J

    2015-03-19

    We analyzed cost-effectiveness studies related to hematologic malignancies from the Tufts Medical Center Cost-Effectiveness Analysis Registry (www.cearegistry.org), focusing on studies of innovative therapies. Studies that met inclusion criteria were categorized by 4 cancer types (chronic myeloid leukemia, chronic lymphocytic leukemia, non-Hodgkin lymphoma, and multiple myeloma) and 9 treatment agents (interferon-α, alemtuzumab, bendamustine, bortezomib, dasatinib, imatinib, lenalidomide, rituximab alone or in combination, and thalidomide). We examined study characteristics and stratified cost-effectiveness ratios by type of cancer, treatment, funder, and year of study publication. Twenty-nine studies published in the years 1996-2012 (including 44 cost-effectiveness ratios) met inclusion criteria, 22 (76%) of which were industry funded. Most ratios fell below $50,000 per quality-adjusted life-years (QALY) (73%) and $100,000/QALY (86%). Industry-funded studies (n = 22) reported a lower median ratio ($26,000/QALY) than others (n = 7; $33,000/QALY), although the difference was not statistically significant. Published data suggest that innovative treatments for hematologic malignancies may provide reasonable value for money. © 2015 by The American Society of Hematology.

  14. Hematological profile of sickle cell disease from South Gujarat, India

    Directory of Open Access Journals (Sweden)

    Sanjeev Shyam Rao

    2012-05-01

    Full Text Available The aim of this study was to determine hematological profile of sickle cell disease (SCD from Surat, South Gujarat, India. This prospective cross-sectional study was conducted in the Department of Pediatrics and Sickle Cell Anemia Laboratory, Faculty of Pathology, Government Medical College, Surat, India, between July 2009 and December 2010. Patients included in this study were in their steady state for a long period of time without any symptoms related to SCD or other diseases which could affect the hematological parameters. Venous blood of all patients was collected in ethylenediaminetetraacetic acid and hematological indices were measured. Thirty-three subjects homozygous in all were studied for their hematological parameters for sickle cell anemia. Moderate to severe anemia, low mean cell volume and high foetal hemoglobin dominate the hematological profile of SCD children.

  15. BEST-TEST2: assessment of hematology trainee knowledge of transfusion medicine.

    Science.gov (United States)

    Lin, Yulia; Tinmouth, Alan; Mallick, Ranjeeta; Haspel, Richard L

    2016-02-01

    As transfusion is a common therapy and key component in every hematologist's practice, hematology training programs should dedicate significant time and effort to delivering high-quality transfusion medicine education to their trainees. The current state of hematology trainee knowledge of transfusion medicine is not known. A validated assessment tool developed by the Biomedical Excellence for Safer Transfusion (BEST) Collaborative was used to assess prior transfusion medicine education, attitudes, perceived ability, and transfusion medicine knowledge of hematology trainees. A total of 149 hematology trainees at 17 international sites were assessed. The overall mean exam score was 61.6% (standard deviation, 13.4%; range, 30%-100%) with no correlation in exam scores with postgraduate year or previous transfusion medicine education in medical school or internal medicine residency. However, better scores correlated with 3 or more hours of transfusion medicine education (p = 0.0003) and perceived higher-quality education during hematology training (p = 0.03). Hematology trainees at US sites, where hematology is often combined with oncology training, had statistically lower scores than trainees at non-US sites (56.2% vs. 67.4%; p hematology training programs to reevaluate the quality and quantity of transfusion medicine training and can assist in the development of targeted curricula. © 2015 AABB.

  16. Direct pumping of ultrashort Ti:sapphire lasers by a frequency doubled diode laser

    DEFF Research Database (Denmark)

    Müller, André; Jensen, Ole Bjarlin; Unterhuber, Angelika

    2011-01-01

    electro-optical efficiency of the diode laser. Autocorrelation measurements show that pulse widths of less than 20 fs can be expected with an average power of 52 mW when using our laser. These results indicate the high potential of direct diode laser pumped Ti: sapphire lasers to be used in applications....... When using our diode laser system, the optical conversion efficiencies from green to near-infrared light reduces to 75 % of the values achieved with the commercial pump laser. Despite this reduction the overall efficiency of the Ti: sapphire laser is still increased by a factor > 2 due to the superior...... like retinal optical coherence tomography (OCT) or pumping of photonic crystal fibers for CARS (coherent anti-stokes Raman spectroscopy) microscopy....

  17. Electrical parameters of silicon on sapphire; influence on aluminium gate MOS devices performances

    International Nuclear Information System (INIS)

    Suat, J.P.; Borel, J.

    1976-01-01

    The question is the quality level of the substrate obtained with MOS technologies on silicon on an insulating substrate. Experimental results are presented on the main electrical parameters of MOS transistors made on silicon on sapphire, e.g. mean values and spreads of: threhold voltage and surface mobilities of transistors, breakdown voltages, and leakage currents of diodes. These devices have been made in three different technologies: enhancement P. channel technology, depletion-enhancement P. channel technology, and complementary MOS technology. These technologies are all aluminium gate processes with standard design rules and 5μm channel length. Measurements show that presently available silicon on sapphire can be considered as a very suitable substrate for many MOS digital applications (but not for dynamic circuits) [fr

  18. Gold wetting effects on sapphire irradiated with GeV uranium ions

    International Nuclear Information System (INIS)

    Ramos, S.M.M.

    1997-01-01

    Single crystals of α-Al 2 O 3 were irradiated with 238 U ions using two different energies: 3.4 MeV/u and 1.7 MeV/u. The irradiations were performed at a temperature of ∼80 K, with fluences ranging from 1.2 x 10 12 to 2.5 x 10 12 ions cm -2 . After irradiation, thin gold films were deposited on the sapphire surfaces by using a sputtering method. Subsequent annealing in air at a temperature of 723 and 923 K were applied to investigate the influence of the pre-damage on the adhesion of the gold layer on the sapphire surface. Rutherford backscattering analysis and scanning electron microscopy performed in both virgin and irradiated areas, show that the pre-irradiation damage inhibits the gold film of breaking up into islands after annealing. A wetting effect, which could depend on the damage morphology, is clearly observed. (orig.)

  19. Use of contact Nd:YAG sapphire-laser system for performing partial hepatectomy and splenectomy in dogs

    Science.gov (United States)

    Yu, Chibing; Jing, Shujuan; Cai, Huimin; Shao, Lanxing; Zou, Hegui

    1993-03-01

    An Nd:YAG Sapphire laser blade was used for performing hepatectomy and splenectomy in dogs. The results suggest that a laser blade provides a new way to reduce intraoperative bleeding and to minimize tissue damage. In recent years, there have been some reports on performing surgical procedures using a contact Nd:YAG Sapphire laser system. The current animal study was conducted in order to explore the capability of incision and excision of the laser tip, the damage to the tissue, and the recovery course.

  20. Preparation of YBCO on YSZ layers deposited on silicon and sapphire by MOCVD: influence of the intermediate layer on the quality of the superconducting film

    International Nuclear Information System (INIS)

    Garcia, G.; Casado, J.; Llibre, J.; Doudkowski, M.; Santiso, J.; Figueras, A.; Schamm, S.; Dorignac, D.; Grigis, C.; Aguilo, M.

    1995-01-01

    YSZ buffer layers were deposited on silicon and sapphire by MOCVD. The layers deposited on silicon were highly oriented along [100] direction without in-plane orientation, probably because the existence of the SiO 2 amorphous interlayer. In contrast, epitaxial YSZ was obtained on (1-102) sapphire showing an in-plane texture defined by the following relationships: (100) YSZ // (1-102) sapphire and (110) YSZ // (01-12) sapphire. Subsequently, YBCO films were deposited on YSZ by MOCVD. Structural, morphological and electrical characterization of the superconducting layers were correlated with the in-plane texture of the buffer layers. (orig.)

  1. Breed-specific hematological phenotypes in the dog: a natural resource for the genetic dissection of hematological parameters in a mammalian species.

    Directory of Open Access Journals (Sweden)

    Jennifer Lawrence

    Full Text Available Remarkably little has been published on hematological phenotypes of the domestic dog, the most polymorphic species on the planet. Information on the signalment and complete blood cell count of all dogs with normal red and white blood cell parameters judged by existing reference intervals was extracted from a veterinary database. Normal hematological profiles were available for 6046 dogs, 5447 of which also had machine platelet concentrations within the reference interval. Seventy-five pure breeds plus a mixed breed control group were represented by 10 or more dogs. All measured parameters except mean corpuscular hemoglobin concentration (MCHC varied with age. Concentrations of white blood cells (WBCs, neutrophils, monocytes, lymphocytes, eosinophils and platelets, but not red blood cell parameters, all varied with sex. Neutering status had an impact on hemoglobin concentration, mean corpuscular hemoglobin (MCH, MCHC, and concentrations of WBCs, neutrophils, monocytes, lymphocytes and platelets. Principal component analysis of hematological data revealed 37 pure breeds with distinctive phenotypes. Furthermore, all hematological parameters except MCHC showed significant differences between specific individual breeds and the mixed breed group. Twenty-nine breeds had distinctive phenotypes when assessed in this way, of which 19 had already been identified by principal component analysis. Tentative breed-specific reference intervals were generated for breeds with a distinctive phenotype identified by comparative analysis. This study represents the first large-scale analysis of hematological phenotypes in the dog and underlines the important potential of this species in the elucidation of genetic determinants of hematological traits, triangulating phenotype, breed and genetic predisposition.

  2. Time dependent temperature distribution in pulsed Ti:sapphire lasers

    Science.gov (United States)

    Buoncristiani, A. Martin; Byvik, Charles E.; Farrukh, Usamah O.

    1988-01-01

    An expression is derived for the time dependent temperature distribution in a finite solid state laser rod for an end-pumped beam of arbitrary shape. The specific case of end pumping by circular (constant) or Gaussian beam is described. The temperature profile for a single pump pulse and for repetitive pulse operation is discussed. The particular case of the temperature distribution in a pulsed titanium:sapphire rod is considered.

  3. The Effects of Altitude Training on Erythropoietic Response and Hematological Variables in Adult Athletes: A Narrative Review

    Directory of Open Access Journals (Sweden)

    Kamila Płoszczyca

    2018-04-01

    Full Text Available Background: One of the goals of altitude training is to increase blood oxygen-carrying capacity in order to improve sea-level endurance performance in athletes. The elevated erythropoietin (EPO production in hypoxia is a key factor in the achievement of enhanced hematological variables. The level of the EPO increase and acceleration of erythropoiesis depend on the duration of exposure and degree of hypoxia. Furthermore, many other factors may affect the hematological response to altitude training.Aim: The purpose of this narrative review was to: (1 analyze the kinetics of EPO and hematological variables during and after altitude training; (2 summarize the current state of knowledge about the possible causes of individual or cohort differences in EPO and hematological response to altitude training; (3 formulate practical guidelines for athletes to improve the efficiency of altitude training.Methods: A narrative review was performed following an electronic search of the databases PubMed/MEDLINE and SPORTDiscus via EBSCO for all English-language articles published between 1997 and 2017.Results: Complete unification of results from studies on EPO kinetics was difficult due to different time and frequency of blood sampling by different researchers during and after altitude training, but the data presented in the reviewed literature allowed us to detect certain trends. The results of the reviewed studies were divergent and indicated either increase or no change of hematological variables following altitude training. Factors that may affect the hematological response to altitude training include hypoxic dose, training content, training background of athletes, and/or individual variability of EPO production.Conclusions: Despite the potential benefits arising from altitude training, its effectiveness in improving hematological variables is still debatable. Further research and better understanding of factors influencing the response to altitude, as well

  4. The Effects of Altitude Training on Erythropoietic Response and Hematological Variables in Adult Athletes: A Narrative Review

    Science.gov (United States)

    Płoszczyca, Kamila; Langfort, Józef; Czuba, Miłosz

    2018-01-01

    Background: One of the goals of altitude training is to increase blood oxygen-carrying capacity in order to improve sea-level endurance performance in athletes. The elevated erythropoietin (EPO) production in hypoxia is a key factor in the achievement of enhanced hematological variables. The level of the EPO increase and acceleration of erythropoiesis depend on the duration of exposure and degree of hypoxia. Furthermore, many other factors may affect the hematological response to altitude training. Aim: The purpose of this narrative review was to: (1) analyze the kinetics of EPO and hematological variables during and after altitude training; (2) summarize the current state of knowledge about the possible causes of individual or cohort differences in EPO and hematological response to altitude training; (3) formulate practical guidelines for athletes to improve the efficiency of altitude training. Methods: A narrative review was performed following an electronic search of the databases PubMed/MEDLINE and SPORTDiscus via EBSCO for all English-language articles published between 1997 and 2017. Results: Complete unification of results from studies on EPO kinetics was difficult due to different time and frequency of blood sampling by different researchers during and after altitude training, but the data presented in the reviewed literature allowed us to detect certain trends. The results of the reviewed studies were divergent and indicated either increase or no change of hematological variables following altitude training. Factors that may affect the hematological response to altitude training include hypoxic dose, training content, training background of athletes, and/or individual variability of EPO production. Conclusions: Despite the potential benefits arising from altitude training, its effectiveness in improving hematological variables is still debatable. Further research and better understanding of factors influencing the response to altitude, as well as factors

  5. The Effects of Altitude Training on Erythropoietic Response and Hematological Variables in Adult Athletes: A Narrative Review.

    Science.gov (United States)

    Płoszczyca, Kamila; Langfort, Józef; Czuba, Miłosz

    2018-01-01

    Background: One of the goals of altitude training is to increase blood oxygen-carrying capacity in order to improve sea-level endurance performance in athletes. The elevated erythropoietin (EPO) production in hypoxia is a key factor in the achievement of enhanced hematological variables. The level of the EPO increase and acceleration of erythropoiesis depend on the duration of exposure and degree of hypoxia. Furthermore, many other factors may affect the hematological response to altitude training. Aim: The purpose of this narrative review was to: (1) analyze the kinetics of EPO and hematological variables during and after altitude training; (2) summarize the current state of knowledge about the possible causes of individual or cohort differences in EPO and hematological response to altitude training; (3) formulate practical guidelines for athletes to improve the efficiency of altitude training. Methods: A narrative review was performed following an electronic search of the databases PubMed/MEDLINE and SPORTDiscus via EBSCO for all English-language articles published between 1997 and 2017. Results: Complete unification of results from studies on EPO kinetics was difficult due to different time and frequency of blood sampling by different researchers during and after altitude training, but the data presented in the reviewed literature allowed us to detect certain trends. The results of the reviewed studies were divergent and indicated either increase or no change of hematological variables following altitude training. Factors that may affect the hematological response to altitude training include hypoxic dose, training content, training background of athletes, and/or individual variability of EPO production. Conclusions: Despite the potential benefits arising from altitude training, its effectiveness in improving hematological variables is still debatable. Further research and better understanding of factors influencing the response to altitude, as well as factors

  6. Association of the blood eosinophil count with hematological malignancies and mortality

    DEFF Research Database (Denmark)

    Andersen, Christen Bertel L; Siersma, Volkert Dirk; Hasselbalch, Hans K

    2015-01-01

    Blood eosinophilia (≥0.5 × 109/l) may be an early sign of hematological malignancy. We investigated associations between levels of blood eosinophils and risks of hematological malignancies and mortality in order to provide clinically derived cut-offs for referral to specialist hematology care. Fr...

  7. Ultrafast, ultrahigh-peak power Ti:sapphire laser system

    Energy Technology Data Exchange (ETDEWEB)

    Yamakawa, Koichi; Aoyama, Makoto; Matsuoka, Shinichi; Akahane, Yutaka; Kase, Teiji; Nakano, Fumihiko; Sagisaka, Akito [Advanced Photon Research Center, Kansai Research Establishment, Japan Atomic Energy Research Inst., Kizu, Kyoto (Japan)

    2001-01-01

    We review progress in the generation of multiterawatt optical pulses in the 10-fs range. We describe a design, performance and characterization of a Ti:sapphire laser system based on chirped-pulse amplification, which has produced a peak power in excess of 100-TW with sub-20-fs pulse durations and an average power of 19-W at a 10-Hz repetition rate. We also discuss extension of this system to the petawatt power level and potential applications in the relativistic, ultrahigh intensity regimes. (author)

  8. Growth optimization for thick crack-free GaN layers on sapphire with HVPE

    Energy Technology Data Exchange (ETDEWEB)

    Richter, E.; Hennig, Ch.; Kissel, H.; Sonia, G.; Zeimer, U.; Weyers, M. [Ferdinand-Braun-Institut fuer Hoechstfrequenztechnik, 12489 Berlin (Germany)

    2005-05-01

    Conditions for optimized growth of thick GaN layers with crack-free surfaces by HVPE are reported. It was found that a 1:1 mixture of H{sub 2}/N{sub 2} as carrier gas leads to the lowest density of cracks in the surface. Crack formation also depends on the properties of the GaN/sapphire templates used. Best results have been obtained for 5 {mu}m thick GaN/sapphire templates grown by MOVPE with medium compressive strain {epsilon}{sub zz} of about 0.05%. But there is no simple dependence of the crack formation on the strain status of the starting layer indicating that the HVPE growth of GaN can itself introduce strong tensile strain. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  9. Contamination-Free Graphene Transfer from Cu-Foil and Cu-Thin-Film/Sapphire

    Directory of Open Access Journals (Sweden)

    Jaeyeong Lee

    2017-12-01

    Full Text Available The separation of graphene grown on metallic catalyst by chemical vapor deposition (CVD is essential for device applications. The transfer techniques of graphene from metallic catalyst to target substrate usually use the chemical etching method to dissolve the metallic catalyst. However, this causes not only high material cost but also environmental contamination in large-scale fabrication. We report a bubble transfer method to transfer graphene films to arbitrary substrate, which is nondestructive to both the graphene and the metallic catalyst. In addition, we report a type of metallic catalyst, which is 700 nm of Cu on sapphire substrate, which is hard enough to endure against any procedure in graphene growth and transfer. With the Cr adhesion layer between sapphire and Cu film, electrochemically delaminated graphene shows great quality during several growth cycles. The electrochemical bubble transfer method can offer high cost efficiency, little contamination and environmental advantages.

  10. Effect of subchronic administration of nutmeg (Myristica fragrans Houtt) ethanolic extract to hematological parameters in rat

    Science.gov (United States)

    Bachri, M. S.; Yuliani, S.; Sari, A. K.

    2017-11-01

    Nutmeg is dried kernel of broadly ovoid seed of Myristica fragrans Houtt. It has been mentioned in ethnomedical literature as aphrodisiac, stomachic, carminative, tonic, and nervous stimulant. In order to establish the safety of nutmeg, the effect of the repeated administration of nutmeg is needed. The study was aimed to determine the toxic effect of subchronic administration of nutmeg ethanolic extract to hematological parameters in rat. A total of 28 male adult Wistar rats divided into 4 groups. Group I as control was given by 0.5% CMC-suspension, group II, III, and IV were given by 50, 100, and 200 mg/kg bw, respectively, of nutmeg ethanolic extract. The treatments were administered daily for 31 days. On day 31 bloods were taken from orbital sinus. The hematological parameter consisted of the numbers of erythrocyte and leukocyte as well as hemoglobin and total protein levels were measured. The data were statistically analyzed by one way Anova followed by LSD test. All of observed hematological parameters in rats showed that there were no significant difference between the nutmeg ethanolic extract treated groups and control group. The result indicated that the subchronic administration of 50, 100, and 200 mg/kg bw of nutmeg ethanolic extract did not cause the change of hematological parameters in rat.

  11. Hematology - Open TG-GATEs | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available ivo tests. Data file File name: open_tggates_hematology.zip File URL: ftp://ftp.biosciencedbc.jp/archive/ope...n-tggates/LATEST/open_tggates_hematology.zip File size: 636 KB Simple search URL ...http://togodb.biosciencedbc.jp/togodb/view/open_tggates_hematology#en Data acquisition method - Data analysi

  12. Chemotherapy and Cardiotoxicity in Hematologic Malignancies.

    Science.gov (United States)

    Stellitano, Antonio; Fedele, Roberta; Barilla, Santina; Iaria, Antonino; Rao, Carmelo Massimiliano; Martino, Massimo

    2017-01-01

    Antineoplastic agents affect the cardiovascular system, and the incidence of cardiotoxicity is continuously growing in patients with hematologic malignancies and treated with antineoplastic therapy. In this mini-review, we analyzed existing literature which evaluates the likelihood of cardiotoxicity related to the main agents employed in the treatment of hematologic malignancies. There is a significant need to optimize the early identification of patients who are at risk of cardiotoxicity. The conventional echocardiographic measurements used to detect cardiac alterations, such as LVEF, fractional shortening, diameters and volumes, allow only a late diagnosis of cardiac dysfunction, which might be already irreversible. The early identification of patients at risk for rapid progression towards irreversible cardiac failure has a primary purpose, the opportunity for them to benefit from early preventive and therapeutic measures. A useful imaging technique that points in this direction detecting subclinical LVD may be the speckle tracking echocardiography, that has demonstrated a previous detection of myocardial contractile dysfunction compared to the traditional left ventricular ejection fraction. In this view, the discovery of new biomarkers to identify patients at a high risk for the development of these complications is another priority. Cardiotoxicity induced by anticancer drugs is always the outcome of several concurrent factors. It is plausible that an asymptomatic dysfunction precedes clinical events. During this asymptomatic phase, an early treatment prepares the patient for cardiovascular "safety" conditions; on the other hand, a late or missing treatment paves the ground for the development of future cardiac events. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  13. Evaluating the Type of Light Transmittance in Mono Crystalline, Poly Crystalline and Sapphire Brackets- An Invitro Spectrofluorometer Study.

    Science.gov (United States)

    Mohamed, Jauhar P; Kommi, Pradeep Babu; Kumar, M Senthil; Hanumanth; Venkatesan; Aniruddh; Arvinth; Kumar, Arani Nanda

    2016-08-01

    Most of the patients seek orthodontic treatment to improve the smile, which improves the facial profile by means of fixed appliances i.e., brackets and wires. The brackets are of different types like stainless steel and ceramic. Ceramic brackets were considered as aesthetic appliance which was divided into mono-crystalline, polycrystalline and sapphire brackets. The light transmittance might influence the degree of curing adhesive material in mono crystalline, polycrystalline and sapphire brackets. The aim of the present study was to evaluate the translucency and intensity of three different aesthetic brackets (mono crystalline, poly crystalline and sapphire ceramic brackets) and to determine their influence on shear bond strength of the brackets. The adhesive remnant index was also measured after debonding of the brackets from the tooth surface. Twenty six samples each of monocrystalline, polycrystalline and sapphire brackets (total 78 ceramic brackets) were used for the study. The bracket samples were subjected to optical fluorescence test using spectrofluorometer to measure the intensity of the brackets. Seventy eight extracted premolar teeth were procured and divided into 3 groups. The brackets were then bonded to the tooth using Transbond XT (3M Unitek) light cure composite material and cured with new light cure unit (Light Emitting Diode) of wood pecker company (400-450nm) for 30 seconds, and these samples were subjected to shear bond strength test with Instron Universal Testing Machine (UNITEK-94100) with a load range between 0 to 100 KN with a maximum cross head speed of 0.5mm/min. ARI (Adhesive Remnant Index) scores were evaluated according to Artun and Bergland scoring system using stereomicroscope at 20x magnification. The light absorption values obtained from spectrofluorometeric study were 3300000-3500000 cps for group 1 (monocrystalline ceramic brackets), 6000000-6500000 cps for Group 2 (polycrystalline ceramic brackets) and 2700000 -3000000 cps for

  14. Erbium medium temperature localised doping into lithium niobate and sapphire: A comparative study

    Czech Academy of Sciences Publication Activity Database

    Nekvindová, P.; Macková, Anna; Peřina, Vratislav; Červená, Jarmila; Čapek, P.; Schrofel, J.; Špirková, J.; Oswald, Jiří

    90-91, - (2003), s. 559-564 ISSN 1012-0394 Institutional research plan: CEZ:AV0Z1048901 Keywords : lithium niobate * sapphire * erbium Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.687, year: 2003

  15. Effects of dance therapy on the selected hematological and rheological indicators in older women.

    Science.gov (United States)

    Filar-Mierzwa, Katarzyna; Marchewka, Anna; Bac, Aneta; Kulis, Aleksandra; Dąbrowski, Zbigniew; Teległów, Aneta

    2017-01-01

    The aim of this study was to analyze the effects of dance therapy on selected hematological and rheological indicators in older women. The study included 30 women (aged 71.8±7.4), and the control group comprised of 10 women of corresponding age. Women from the experimental group were subjected to a five-month dance therapy program (three 45-minute sessions per week); women from the control group were not involved in any regular physical activity. Blood samples from all the women were examined for hematological, rheological, and biochemical parameters prior to the study and five months thereafter. The dance therapy program was reflected by a significant improvement of erythrocyte count and hematocrit. Furthermore, the dance therapy resulted in a significant increase in the plasma viscosity, while no significant changes in glucose and fibrinogen levels were noted. Dance therapy modulates selected hematological parameters of older women; it leads to increase in erythrocyte count and hematocrit level. Dance therapy is reflected by higher plasma viscosity. Concentrations of fibrinogen and glucose are not affected by the dance therapy in older women, suggesting maintenance of homeostasis. Those findings advocate implementation of dance therapy programs in older women.

  16. Microarray Gene Expression Analysis to Evaluate Cell Type Specific Expression of Targets Relevant for Immunotherapy of Hematological Malignancies.

    Directory of Open Access Journals (Sweden)

    M J Pont

    Full Text Available Cellular immunotherapy has proven to be effective in the treatment of hematological cancers by donor lymphocyte infusion after allogeneic hematopoietic stem cell transplantation and more recently by targeted therapy with chimeric antigen or T-cell receptor-engineered T cells. However, dependent on the tissue distribution of the antigens that are targeted, anti-tumor responses can be accompanied by undesired side effects. Therefore, detailed tissue distribution analysis is essential to estimate potential efficacy and toxicity of candidate targets for immunotherapy of hematological malignancies. We performed microarray gene expression analysis of hematological malignancies of different origins, healthy hematopoietic cells and various non-hematopoietic cell types from organs that are often targeted in detrimental immune responses after allogeneic stem cell transplantation leading to graft-versus-host disease. Non-hematopoietic cells were also cultured in the presence of IFN-γ to analyze gene expression under inflammatory circumstances. Gene expression was investigated by Illumina HT12.0 microarrays and quality control analysis was performed to confirm the cell-type origin and exclude contamination of non-hematopoietic cell samples with peripheral blood cells. Microarray data were validated by quantitative RT-PCR showing strong correlations between both platforms. Detailed gene expression profiles were generated for various minor histocompatibility antigens and B-cell surface antigens to illustrate the value of the microarray dataset to estimate efficacy and toxicity of candidate targets for immunotherapy. In conclusion, our microarray database provides a relevant platform to analyze and select candidate antigens with hematopoietic (lineage-restricted expression as potential targets for immunotherapy of hematological cancers.

  17. Photonics of 2D gold nanolayers on sapphire surface

    Energy Technology Data Exchange (ETDEWEB)

    Muslimov, A. E., E-mail: amuslimov@mail.ru; Butashin, A. V.; Nabatov, B. V. [Russian Academy of Sciences, Shubnikov Institute of Crystallography, Federal Research Center “Crystallography and Photonics” (Russian Federation); Konovko, A. A.; Belov, I. V.; Gizetdinov, R. M.; Andreev, A. V. [Moscow State University (Russian Federation); Kanevsky, V. M. [Russian Academy of Sciences, Shubnikov Institute of Crystallography, Federal Research Center “Crystallography and Photonics” (Russian Federation)

    2017-03-15

    Gold layers with thicknesses of up to several nanometers, including ordered and disordered 2D nanostructures of gold particles, have been formed on sapphire substrates; their morphology is described; and optical investigations are carried out. The possibility of increasing the accuracy of predicting the optical properties of gold layers and 2D nanostructures using quantum-mechanical models based on functional density theory calculation techniques is considered. The application potential of the obtained materials in photonics is estimated.

  18. Bleeding frequency and characteristics among hematologic malignancy inpatient rehabilitation patients with severe thrombocytopenia.

    Science.gov (United States)

    Fu, Jack B; Tennison, Jegy M; Rutzen-Lopez, Isabel M; Silver, Julie K; Morishita, Shinichiro; Dibaj, Seyedeh S; Bruera, Eduardo

    2018-03-28

    To identify the frequency and characteristics of bleeding complications during acute inpatient rehabilitation of hematologic malignancy patients with severe thrombocytopenia. Retrospective descriptive analysis. Comprehensive cancer center acute inpatient rehabilitation unit. Consecutive hematologic malignancy patients with a platelet count of less than or equal to 20,000/microliter (μL) on the day of acute inpatient rehabilitation admission from 1/1/2005 through 8/31/2016. Medical records were retrospectively analyzed for demographic, laboratory, and medical data. Patients were rehabilitated using the institutional exercise guidelines for thrombocytopenic patients. Bleeding events noted in the medical record. Out of 135 acute inpatient rehabilitation admissions, 133 unique patients were analyzed with a total of 851 inpatient rehabilitation days. The mean platelet count was 14,000/μL on the day of admission and 22,000/μL over the course of the rehabilitation admission. There were 252 days of inpatient rehabilitation where patients had less than 10,000/μL platelets. A total of 97 bleeding events were documented in 77/135 (57%) admissions. Of the 97 bleeding events, 72 (74%), 14 (14%), and 11 (11%) were considered to be of low, medium, and high severity, respectively. There were 4/97 (4%) bleeding events that were highly likely attributable to physical activity but only 1/4 was considered high severity. Bleeding rates were .09, .08, .17, and .37 for > 20,000, 15-20,000, 10-15,000, and rehabilitation in severely thrombocytopenic hematologic cancer patients. Bleeding rates increased with lower platelet counts. However, using the exercise guidelines for severely thrombocytopenic patients, the risk of severe exercise-related bleeding events was low.

  19. Improvement in light-output efficiency of near-ultraviolet InGaN-GaN LEDs fabricated on stripe patterned sapphire substrates

    International Nuclear Information System (INIS)

    Lee, Y.J.; Hsu, T.C.; Kuo, H.C.; Wang, S.C.; Yang, Y.L.; Yen, S.N.; Chu, Y.T.; Shen, Y.J.; Hsieh, M.H.; Jou, M.J.; Lee, B.J.

    2005-01-01

    InGaN/GaN multi-quantum wells near ultraviolet light-emitting diodes (LEDs) were fabricated on a patterned sapphire substrate (PSS) with parallel stripe along the sapphire direction by using low-pressure metal-organic chemical vapor deposition (MOCVD). The forward- and reverse-bias electrical characteristics of the stripe PSS LEDs are, respectively, similar and better than those of conventional LEDs on sapphire substrate. The output power of the epoxy package of stripe PSS LED was 20% higher than that of the conventional LEDs. The enhancement of output power is due not only to the reduction of dislocation density but also to the release of the guided light in LEDs by the geometric shape of the stripe PSS, according to the ray-tracing analysis

  20. Weights, hematology and serum chemistry of seven species of free-ranging tropical pelagic seabirds

    Science.gov (United States)

    Work, Thierry M.

    1996-01-01

    I established reference values for weight, hematology, and serum chemistry for seven species of free-ranging Hawaiian tropical pelagic seabirds comprising three orders (Procellariiformes, Pelecaniformes, Charadriiformes) and six families (Procellariidae, Phaethontidae, Diomedeidae, Sulidae, Fregatidae, and Laridae). Species examined included 84 Hawaiian dark-rumped petrels (Pterodoma phaeopygia), 90 wedge-tailed shearwaters (Puffinus pacificus), 151 Laysan albatrosses (Diomedea immutabilis), 69 red-footed boobies (Sula sula), 154 red-tailed tropicbirds (Phaeton rubricauda), 90 great frigatebirds (Fregata minor), and 72 sooty terns (Sterna fuscata). Hematocrit, total plasma solids, total and differential white cell counts, serum glucose, calcium, phosphorus, uric acid, total protein, albumin, globulin, aspartate aminotransferase and creatinine phosphokinase were analyzed. Among and within species, hematology and chemistry values varied with age, sex, season, and island of collection. Despite this variation, order-wide trends were observed.

  1. Structural properties, crystal quality and growth modes of MOCVD-grown AlN with TMAl pretreatment of sapphire substrate

    KAUST Repository

    Sun, Haiding; Wu, Feng; Altahtamouni, Talal Mohammed Ahmad; Alfaraj, Nasir; Li, Kun; Detchprohm, Theeradetch; Dupuis, Russell; Li, Xiaohang

    2017-01-01

    The growth of high quality AlN epitaxial films relies on precise control of the initial growth stages. In this work, we examined the influence of the trimethylaluminum (TMAl) pretreatment of sapphire substrates on the structural properties, crystal quality and growth modes of heteroepitaxial AlN films on (0001) sapphire substrates. Without the pretreatment, the AlN films nucleated on the smooth surface but exhibited mixed crystallographic Al- (N-) polarity, resulting in rough AlN film surfaces. With increasing the pretreatment time from 1 to 5 s, the N-polarity started to be impeded. However, small islands were formed on sapphire surface due to the decompostion of TMAl. As a result, small voids became noticeable at the nucleation layer (NL) because the growth started as quasi three-dimensional (3D) but transformed to 2D mode as the film grew thicker and got coalesced, leading to smoother and Al-polar films. On the other hand, longer pretreatment time of 40 s formed large 3D islands on sapphire, and thus initiated a 3D-growth mode of the AlN film, generating Al-polar AlN nanocolumns with different facets, which resulted into rougher film surfaces. The epitaxial growth modes and their correlation with the AlN film crystal quality under different TMAl pretreatments are also discussed.

  2. Structural properties, crystal quality and growth modes of MOCVD-grown AlN with TMAl pretreatment of sapphire substrate

    KAUST Repository

    Sun, Haiding

    2017-08-08

    The growth of high quality AlN epitaxial films relies on precise control of the initial growth stages. In this work, we examined the influence of the trimethylaluminum (TMAl) pretreatment of sapphire substrates on the structural properties, crystal quality and growth modes of heteroepitaxial AlN films on (0001) sapphire substrates. Without the pretreatment, the AlN films nucleated on the smooth surface but exhibited mixed crystallographic Al- (N-) polarity, resulting in rough AlN film surfaces. With increasing the pretreatment time from 1 to 5 s, the N-polarity started to be impeded. However, small islands were formed on sapphire surface due to the decompostion of TMAl. As a result, small voids became noticeable at the nucleation layer (NL) because the growth started as quasi three-dimensional (3D) but transformed to 2D mode as the film grew thicker and got coalesced, leading to smoother and Al-polar films. On the other hand, longer pretreatment time of 40 s formed large 3D islands on sapphire, and thus initiated a 3D-growth mode of the AlN film, generating Al-polar AlN nanocolumns with different facets, which resulted into rougher film surfaces. The epitaxial growth modes and their correlation with the AlN film crystal quality under different TMAl pretreatments are also discussed.

  3. Numerical investigation of thermal and residual stress of sapphire during c-axis vertical Bridgman growth process considering the solidification history effect

    Science.gov (United States)

    Hwang, Ji Hoon; Lee, Young Cheol; Lee, Wook Jin

    2018-01-01

    Sapphire single crystals have been highlighted for epitaxial of gallium nitride films in high-power laser and light emitting diode industries. In this study, the evolution of thermally induced stress in sapphire during the vertical Bridgman crystal growth process was investigated using a finite element model that simplified the real Bridgman process. A vertical Bridgman process of cylindrical sapphire crystal with a diameter of 50 mm was considered for the model. The solidification history effect during the growth was modeled by the quite element technique. The effects of temperature gradient, seeding interface shape and seeding position on the thermal stress during the process were discussed based on the finite element analysis results.

  4. Hematologic outcomes after total splenectomy and partial splenectomy for congenital hemolytic anemia.

    Science.gov (United States)

    Englum, Brian R; Rothman, Jennifer; Leonard, Sarah; Reiter, Audra; Thornburg, Courtney; Brindle, Mary; Wright, Nicola; Heeney, Matthew M; Jason Smithers, C; Brown, Rebeccah L; Kalfa, Theodosia; Langer, Jacob C; Cada, Michaela; Oldham, Keith T; Scott, J Paul; St Peter, Shawn D; Sharma, Mukta; Davidoff, Andrew M; Nottage, Kerri; Bernabe, Kathryn; Wilson, David B; Dutta, Sanjeev; Glader, Bertil; Crary, Shelley E; Dassinger, Melvin S; Dunbar, Levette; Islam, Saleem; Kumar, Manjusha; Rescorla, Fred; Bruch, Steve; Campbell, Andrew; Austin, Mary; Sidonio, Robert; Blakely, Martin L; Rice, Henry E

    2016-01-01

    The purpose of this study was to define the hematologic response to total splenectomy (TS) or partial splenectomy (PS) in children with hereditary spherocytosis (HS) or sickle cell disease (SCD). The Splenectomy in Congenital Hemolytic Anemia (SICHA) consortium registry collected hematologic outcomes of children with CHA undergoing TS or PS to 1 year after surgery. Using random effects mixed modeling, we evaluated the association of operative type with change in hemoglobin, reticulocyte counts, and bilirubin. We also compared laparoscopic to open splenectomy. The analysis included 130 children, with 62.3% (n=81) undergoing TS. For children with HS, all hematologic measures improved after TS, including a 4.1g/dl increase in hemoglobin. Hematologic parameters also improved after PS, although the response was less robust (hemoglobin increase 2.4 g/dl, p<0.001). For children with SCD, there was no change in hemoglobin. Laparoscopy was not associated with differences in hematologic outcomes compared to open. TS and laparoscopy were associated with shorter length of stay. Children with HS have an excellent hematologic response after TS or PS, although the hematologic response is more robust following TS. Children with SCD have smaller changes in their hematologic parameters. These data offer guidance to families and clinicians considering TS or PS. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. B-Cell Hematologic Malignancy Vaccination Registry

    Science.gov (United States)

    2017-12-29

    Monoclonal Gammopathy of Undetermined Significance; Multiple Myeloma; Waldenstrom Macroglobulinemia; Lymphocytosis; Lymphoma, Non-Hodgkin; B-Cell Chronic Lymphocytic Leukemia; Hematological Malignancies

  6. Ultrasensitive label-free detection of DNA hybridization by sapphire-based graphene field-effect transistor biosensor

    Science.gov (United States)

    Xu, Shicai; Jiang, Shouzhen; Zhang, Chao; Yue, Weiwei; Zou, Yan; Wang, Guiying; Liu, Huilan; Zhang, Xiumei; Li, Mingzhen; Zhu, Zhanshou; Wang, Jihua

    2018-01-01

    Graphene has attracted much attention in biosensing applications for its unique properties. Because of one-atom layer structure, every atom of graphene is exposed to the environment, making the electronic properties of graphene are very sensitive to charged analytes. Therefore, graphene is an ideal material for transistors in high-performance sensors. Chemical vapor deposition (CVD) method has been demonstrated the most successful method for fabricating large area graphene. However, the conventional CVD methods can only grow graphene on metallic substrate and the graphene has to be transferred to the insulating substrate for further device fabrication. The transfer process creates wrinkles, cracks, or tears on the graphene, which severely degrade electrical properties of graphene. These factors severely degrade the sensing performance of graphene. Here, we directly fabricated graphene on sapphire substrate by high temperature CVD without the use of metal catalysts. The sapphire-based graphene was patterned and make into a DNA biosensor in the configuration of field-effect transistor. The sensors show high performance and achieve the DNA detection sensitivity as low as 100 fM (10-13 M), which is at least 10 times lower than prior transferred CVD G-FET DNA sensors. The use of the sapphire-based G-FETs suggests a promising future for biosensing applications.

  7. Growth of vertically oriented InN nanorods from In-rich conditions on unintentionally patterned sapphire substrates

    Energy Technology Data Exchange (ETDEWEB)

    Terziyska, Penka T., E-mail: pterziy1@lakeheadu.ca [Semiconductor Research Laboratory, Department of Electrical Engineering, Lakehead University, 955 Oliver Road, Thunder Bay, ON P7B 5E1 (Canada); Butcher, Kenneth Scott A. [Semiconductor Research Laboratory, Department of Electrical Engineering, Lakehead University, 955 Oliver Road, Thunder Bay, ON P7B 5E1 (Canada); MEAglow Ltd., Box 398, 2400 Nipigon Road, Thunder Bay, ON P7C4W1 (Canada); Rafailov, Peter [Institute of Solid State Physics, Bulgarian Academy of Sciences, 72 Tzarigradsko Chaussee Blvd., 1784 Sofia (Bulgaria); Alexandrov, Dimiter [Semiconductor Research Laboratory, Department of Electrical Engineering, Lakehead University, 955 Oliver Road, Thunder Bay, ON P7B 5E1 (Canada); MEAglow Ltd., Box 398, 2400 Nipigon Road, Thunder Bay, ON P7C4W1 (Canada)

    2015-10-30

    Highlights: • Vertical InN nanorods are grown on selective areas of sapphire substrates. • In metal droplets nucleate on the sharp needle apexes on the selective areas. • The preferred orientation and the growth direction of the nanorods are (0 0 0 1). • The nanorods grow from the supersaturated indium melt on their tops. - Abstract: Vertically oriented InN nanorods were grown on selective areas of unintentionally patterned c-oriented sapphire substrates exhibiting sharp needles that preferentially accommodate In-metal liquid droplets, using Migration Enhanced Afterglow (MEAglow) growth technique. We point out that the formation of AlN needles on selected areas can be reproduced intentionally by over-nitridation of unmasked areas of sapphire substrates. The liquid indium droplets serve as a self-catalyst and the nanorods grow from the supersaturated indium melt in the droplet in a vertical direction. X-ray diffraction measurements indicate the presence of hexagonal InN only, with preferred orientation along (0 0 0 1) crystal axis, and very good crystalline quality. The room temperature Raman spectrum shows the presence of the A{sub 1}(TO), E{sub 2}(high) and A{sub 1}(LO) phonon modes of the hexagonal InN.

  8. Laboratory hematology in the history of Clinical Chemistry and Laboratory Medicine.

    Science.gov (United States)

    Hoffmann, Johannes J M L

    2013-01-01

    For the occasion of the 50th anniversary of the journal Clinical Chemistry and Laboratory Medicine (CCLM), an historic overview of papers that the journal has published in the field of laboratory hematology (LH) is presented. All past volumes of CCLM were screened for papers on LH and these were categorized. Bibliographic data of these papers were also analyzed. CCLM published in total 387 LH papers. The absolute number of LH papers published annually showed a significant increase over the years since 1985. Also the share of LH papers demonstrated a steady increase (overall mean 5%, but mean 8% over the past 4 years). The most frequent category was coagulation and fibrinolysis (23.5%). Authors from Germany contributed the most LH papers to the journal (22.7%), followed by the Netherlands and Italy (16.3 and 13.2%, respectively). Recent citation data indicated that other publications cited LH review papers much more frequently than other types of papers. The history of the journal reflects the emergence and development of laboratory hematology as a separate discipline of laboratory medicine.

  9. In Vitro Leukoagglutination: A Rare Hematological Cause of Spurious Leukopenia

    Directory of Open Access Journals (Sweden)

    Sadia Sultan

    2017-08-01

    Full Text Available Leukopenia secondary to leukocytic agglutination is caused by an ethylene diamine tetra acetic acid (EDTA which may appear in both benign and malignant states. Ethylene diamine tetra acetic acid induced platelets clumping in peripheral blood has been well established, but invitro leukocytic aggregation is very rarest hematological finding. Pseudo-leukopenia resulting from leukoagglutinins has been reported in the cirrhotic state, infections, autoimmune disorders, uremia, in immunosuppressed state or in various malignancies. Though the condition seems to be benign but very important to be detected as these artifactual findings lead to unnecessary investigations and remarkably changed the overall management plan. Here we report the case of a young patient with this rare finding who was admitted to our hospital with progressive labor pains. The analysis of ethylene diaminetetraacetic acid (EDTA, anticoagulated blood was done on automated hematology analyzer reveals leukopenia. The peripheral smear examination revealed multiple aggregates of leukocytes. On repeat sampling in citrate anticoagulant, the complete blood count showed total leukocytic count of 16.5x109/L with absolute neutrophilic count of 11.5x109/L. This is a rare case of spurious leukopenia secondary to in-vitro leukocytic agglutination provoked by EDTA anticoagulant.

  10. Hematological Parameters in the Volatile Substance Sniffers

    OpenAIRE

    Dündaröz, Ruşen; Ceylan, Süleyman; Denli, Metin; Açıkel, Cengizhan; Balım, Elvan; Özışık, Tahir

    2009-01-01

    SüleymanDemirel Üniversitesi TIP FAKÜLTESİ DERGİSİ: 1999 Eylül; 6(3) Hematological Parameters in the Volatile Substance Sniffers Ruşen Dündaröz, Süleyman Ceylan, Metin Denli, Cengiz Han Açıkel, Elvan Balım, Tahir Özışık Abstract Glue sniffing is a frequent problem among teenagers. Various chemical substances, especially toluene and benzene, contained in the glues kave been reported to be hematotoxic. The hematological parameters of 44 healthy teenagers ~...

  11. Nursing safety management in onco-hematology pediatric wards

    Directory of Open Access Journals (Sweden)

    Marcelle Miranda da Silva

    2015-02-01

    Full Text Available This study aimed at identifying how safety management is applied by nurses to manage the nursing care, and at analyzing their challenges in onco-hematology pediatric wards. Descriptive and qualitative research, conducted at the Instituto Estadual de Hematologia Arthur de Siqueira Cavalcanti, Rio de Janeiro, Brazil, in August 2013. Six nurses were interviewed, and the content analysis was used. The key aspects relate to the importance of training and continuing education, teamwork, with the challenges in the care of hospitalized children and particularities of the disease, and the systematization, use of instruments and protocols. For child safety, the relationship between the administration and support is critical to the quality of care.

  12. STATUS SEROLOGIS TIDAK MEMPENGARUHI PROFIL HEMATOLOGI ANAK TERINFEKSI VIRUS DENGUE

    Directory of Open Access Journals (Sweden)

    Safari Wahyu Jatmiko

    2017-06-01

    Full Text Available Antibodi anti dengue bersifat autoantibodi yang bisa merusak self antigen. Respon imun humoral terhadap DENV adalah terbentuknya IgM dan IgG yang spesifik terhadap sub tipe DENV penyebab. Jika IgG dan IgM anti degue bersifat autoantibodi maka secara teoritis pasien dengan status serologis IgM (+ dan IgG + akan mempunyai profil hematologi yang lebih buruk dari pada pasien dengan IgG (+.Penelitian ini bertjuan untuk mengetahui perbedaan profil hematologi menurut status serologi pada anak terinfeksi virus dengue. Penelitian menggunakan desian analitik dengan pendekatan cross sectional. Data diambil dari pasien anak di RSUD Surakarta dari bulan September 2016 – Januari 2017. Kriteria pasien yang diikutkan dalam penelitian adalah semua pasien anak dengan usia kurang dari 14 tahun dan memenuhi kriteria infeksi virus dengue menurut WHO 2009. Pasien dengan riwayat kelainan hematologi dan pasien dengan riwayat immunocompremised dikeluarkan dari penelitian.Hasil penelitian ditemukan 65 pasien dengan IVD yang memenuhi kriteria.Tujuh belas pasien dengan IgM dan IgG positif sedangkan sisanya hanya IgG positif Hasil penelitian perbedaan profil hematologi jumlah leukosit, trombosit, hematokrit, dan hemoglobin berdasarkan status IgM (+ IgG (+ dengan IgG (+ didapatkan nilai p masing-masing 0.833, 0,865, 0,137, 0,086, dan 0,223. Dapat disimpilkan bahwa tidak terdapat perbedaan profil hematologi antara pasien dengan IgM (+ IgG (+ dengan pasien IgG (+.   Kata Kunci: infeksi virus dengue, antibodi anti dengue, autoantibodi, profil hematologi.

  13. "You Hafta Push": Using Sapphire's Novel to Teach Introduction to American Government

    Science.gov (United States)

    Pappas, Christine

    2007-01-01

    Using fiction in the classroom can dramatize public policy issues and political science concepts, therefore, making them more real and relevant to students. Sapphire's 1996 novel "Push" puts a face on welfare, rape, incest, child abuse, educational inequalities, homophobia, and AIDS. I also use this novel to discuss the public policy process,…

  14. Phase formation and strain relaxation of Ga2O3 on c-plane and a-plane sapphire substrates as studied by synchrotron-based x-ray diffraction

    Science.gov (United States)

    Cheng, Zongzhe; Hanke, Michael; Vogt, Patrick; Bierwagen, Oliver; Trampert, Achim

    2017-10-01

    Heteroepitaxial Ga2O3 was deposited on c-plane and a-plane oriented sapphire by plasma-assisted molecular beam epitaxy and probed by ex-situ and in-situ synchrotron-based x-ray diffraction. The investigation on c-plane sapphire determined a critical thickness of around 33 Å, at which the monoclinic β-phase forms on top of the hexagonal α-phase. A 143 Å thick single phase α-Ga2O3 was observed on a-plane sapphire, much thicker than the α-Ga2O3 on c-plane sapphire. The α-Ga2O3 relaxed very fast in the first 30 Å in both out-of-plane and in-plane directions as measured by the in-situ study.

  15. Epitaxial growth of InN on c-plane sapphire by pulsed laser deposition with r.f. nitrogen radical source

    International Nuclear Information System (INIS)

    Ohta, J.; Fujioka, H.; Honke, T.; Oshima, M.

    2004-01-01

    We have grown InN films on c-plane sapphire substrates by pulsed laser deposition (PLD) with a radio frequency nitrogen radical source for the first time and investigated the effect of the substrate surface nitridation on the structural and electrical properties of InN films with reflection high energy electron diffraction (RHEED), atomic force microscope, the Hall effect measurements and high-resolution X-ray diffraction (HRXRD). RHEED and HRXRD characterizations revealed that high-quality InN grows epitaxially on sapphire by PLD and its epitaxial relationship is InN (0 0 0 1) parallel sapphire (0 0 0 1) and InN [2 -1 -1 0] parallel sapphire [1 0 -1 0]. The InN crystalline quality and the electron mobility are improved by the substrate nitridation process. The area of the pits at the InN surface is reduced by the substrate nitridation process probably due to the reduction in the interface energy between InN and the substrate. The full width at half maximum of the -1 -1 2 4 X-ray rocking curve for InN grown by the present technique without using any buffer layers was as small as 34.8 arcmin. These results indicate that the present technique is promising for the growth of the high-quality InN films

  16. Polar and Nonpolar Gallium Nitride and Zinc Oxide based thin film heterostructures Integrated with Sapphire and Silicon

    Science.gov (United States)

    Gupta, Pranav

    This dissertation work explores the understanding of the relaxation and integration of polar and non-polar of GaN and ZnO thin films with Sapphire and silicon substrates. Strain management and epitaxial analysis has been performed on wurtzitic GaN(0001) thin films grown on c-Sapphire and wurtzitic non-polar a-plane GaN(11-20) thin films grown on r-plane Sapphire (10-12) by remote plasma atomic nitrogen source assisted UHV Pulsed Laser Deposition process. It has been established that high-quality 2-dimensional c-axis GaN(0001) nucleation layers can be grown on c-Sapphire by PLD process at growth temperatures as low as ˜650°C. Whereas the c-axis GaN on c-sapphire has biaxially negative misfit, the crystalline anisotropy of the a-plane GaN films on r-Sapphire results in compressive and tensile misfits in the two major orthogonal directions. The measured strains have been analyzed in detail by X-ray, Raman spectroscopy and TEM. Strain relaxation in GaN(0001)/Sapphire thin film heterostructure has been explained by the principle of domain matched epitaxial growth in large planar misfit system and has been demonstrated by TEM study. An attempt has been made to qualitatively understand the minimization of free energy of the system from the strain perspective. Analysis has been presented to quantify the strain components responsible for the compressive strain observed in the GaN(0001) thin films on c-axis Sapphire substrates. It was also observed that gallium rich deposition conditions in PLD process lead to smoother nucleation layers because of higher ad-atom mobility of gallium. We demonstrate near strain relaxed epitaxial (0001) GaN thin films grown on (111) Si substrates using TiN as intermediate buffer layer by remote nitrogen plasma assisted UHV pulsed laser deposition (PLD). Because of large misfits between the TiN/GaN and TiN/Si systems the TIN buffer layer growth occurs via nucleation of interfacial dislocations under domain matching epitaxy paradigm. X-ray and

  17. Metalorganic vapor phase epitaxy of AlN on sapphire with low etch pit density

    Science.gov (United States)

    Koleske, D. D.; Figiel, J. J.; Alliman, D. L.; Gunning, B. P.; Kempisty, J. M.; Creighton, J. R.; Mishima, A.; Ikenaga, K.

    2017-06-01

    Using metalorganic vapor phase epitaxy, methods were developed to achieve AlN films on sapphire with low etch pit density (EPD). Key to this achievement was using the same AlN growth recipe and only varying the pre-growth conditioning of the quartz-ware. After AlN growth, the quartz-ware was removed from the growth chamber and either exposed to room air or moved into the N2 purged glove box and exposed to H2O vapor. After the quartz-ware was exposed to room air or H2O, the AlN film growth was found to be more reproducible, resulting in films with (0002) and (10-12) x-ray diffraction (XRD) rocking curve linewidths of 200 and 500 arc sec, respectively, and EPDs < 100 cm-2. The EPD was found to correlate with (0002) linewidths, suggesting that the etch pits are associated with open core screw dislocations similar to GaN films. Once reproducible AlN conditions were established using the H2O pre-treatment, it was found that even small doses of trimethylaluminum (TMAl)/NH3 on the quartz-ware surfaces generated AlN films with higher EPDs. The presence of these residual TMAl/NH3-derived coatings in metalorganic vapor phase epitaxy (MOVPE) systems and their impact on the sapphire surface during heating might explain why reproducible growth of AlN on sapphire is difficult.

  18. Laparoscopic Splenectomy for Benign Hematological Disorders in Adults: A Systematic Review.

    Science.gov (United States)

    Moris, Demetrios; Dimitriou, Nikoletta; Griniatsos, John

    2017-01-01

    Since its introduction in the early 1990s, laparoscopic splenectomy (LS) has gained worldwide acceptance for spleen removal, especially in hematological patients. The present review summarizes the current knowledge and results of LS for the treatment of benign hematological diseases in adults. A MEDLINE/PubMed database research was performed using the terms: "laparoscopic splenectomy" OR "laparoscopy" OR "splenectomy" AND "hematological disorders" OR "hematological disease" OR "hematology" AND "adults" as key words. We set our analysis starting date as January 1st 2010 and the end date as December 31st 2016. We identified 247 relative articles. All the references from the identified articles were searched for relevant information. Twenty-seven articles were deemed appropriate for our analysis. LS was found to be feasible and safe in the majority of patients with benign hematological disorders, with a mortality rate ranging from 0% to less than 4% and the postoperative complications rate from 0% to 35.7%. The conversion rate was also very low (4%) and response (complete or partial) was achieved in more than 80% of patients. Lateral approach with four trocars was the most commonly used approach with concommitant cholecystectomy being correlated with increased operative time and morbidity. Current literature holds that whenever splenectomy is required for the treatment of hematological disorders in adults, a laparoscopic approach should be offered as the gold standard. However, to strengthen the clinical evidence in favor of LS, more high-quality clinical trials on several issues of the procedure are necessary. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  19. Wetting phenomena of Al-Cu alloys on sapphire below 800 deg. C

    International Nuclear Information System (INIS)

    Klinter, Andreas J.; Leon-Patino, Carlos A.; Drew, Robin A.L.

    2010-01-01

    Using a modified dispensed drop method, a decrease in contact angle on sapphire from pure aluminum to low-copper-containing Al alloys (7-12 wt.%) was found; with higher copper additions θ transitions to the non-wetting regime. Atomic force microscopy on long-term samples showed a significantly increased surface roughness beneath the drop. Using high-resolution transmission electron microscopy, the reaction product at the interface was identified as CuAl 2 O 4 for Al-7Cu and Al 2 O 3 for an Al-99.99 drop. X-ray photoelectron spectroscopy further confirmed the formation of CuAl 2 O 4 under CuAl 2 drops. Spinel formation is caused by reaction of the alloy with residual oxygen in the furnace that is transported along the interface as modeled by thermodynamic simulations. The formation of CuAl 2 O 4 causes the reduced σ sl and hence the improved wettability of sapphire by low-copper-containing alloys compared to pure aluminum. The main reason for the increase in θ with higher copper contents is the increasing σ lv of the alloy.

  20. The effects of Islamic fasting on blood hematological-biochemical parameters

    Directory of Open Access Journals (Sweden)

    Mohamad Reza Sedaghat

    2017-06-01

    Conclusion:This study on healthy subjects suggests that fasting could affect some hematological-biochemical parameters but not all of them. Also, these changes in hematological-biochemical parameters were within the normal range and Ramadan fasting seems to be safe for healthy subjects.

  1. Green-diode-pumped femtosecond Ti:Sapphire laser with up to 450 mW average power.

    Science.gov (United States)

    Gürel, K; Wittwer, V J; Hoffmann, M; Saraceno, C J; Hakobyan, S; Resan, B; Rohrbacher, A; Weingarten, K; Schilt, S; Südmeyer, T

    2015-11-16

    We investigate power-scaling of green-diode-pumped Ti:Sapphire lasers in continuous-wave (CW) and mode-locked operation. In a first configuration with a total pump power of up to 2 W incident onto the crystal, we achieved a CW power of up to 440 mW and self-starting mode-locking with up to 200 mW average power in 68-fs pulses using semiconductor saturable absorber mirror (SESAM) as saturable absorber. In a second configuration with up to 3 W of pump power incident onto the crystal, we achieved up to 650 mW in CW operation and up to 450 mW in 58-fs pulses using Kerr-lens mode-locking (KLM). The shortest pulse duration was 39 fs, which was achieved at 350 mW average power using KLM. The mode-locked laser generates a pulse train at repetition rates around 400 MHz. No complex cooling system is required: neither the SESAM nor the Ti:Sapphire crystal is actively cooled, only air cooling is applied to the pump diodes using a small fan. Because of mass production for laser displays, we expect that prices for green laser diodes will become very favorable in the near future, opening the door for low-cost Ti:Sapphire lasers. This will be highly attractive for potential mass applications such as biomedical imaging and sensing.

  2. Undergraduate hematology – a more integrated approach

    Directory of Open Access Journals (Sweden)

    Di Carlofelice MA

    2016-11-01

    Full Text Available Matteo A Di Carlofelice,* Jack FT Cope*Faculty of Medicine, Imperial College London, London, UK*These authors contributed equally to this workAs fellow medical students we read with great interest the article by Mandan et al1 proposing a dedicated hematology rotation. The authors highlight a gap in clinical hematology teaching, particularly compared to “conventional rotations”.1 Their suggestion has merits and we agree with most of the points raised; however, propose instead for us to build on current teaching as opposed to establishing a new rotation.The integration of theoretical and practical learning was concluded to be beneficial to both teacher and student by Wrenn and Wrenn.2 In the original article it is mentioned that “clinical experience allows students to comprehend and apply this knowledge in practice, enabling the all-important integration of their learning”.1 As we agree that hematology overlaps with other specialties and therefore requires a thorough understanding, we value how a clinical attachment would be useful to solidify lecture-based teaching.View the original paper by Mandan et al.

  3. High Transparent and Conductive TiO2/Ag/TiO2 Multilayer Electrode Films Deposited on Sapphire Substrate

    Science.gov (United States)

    Loka, Chadrasekhar; Moon, Sung Whan; Choi, YiSik; Lee, Kee-Sun

    2018-03-01

    Transparent conducting oxides attract intense interests due to its diverse industrial applications. In this study, we report sapphire substrate-based TiO2/Ag/TiO2 (TAT) multilayer structure of indium-free transparent conductive multilayer coatings. The TAT thin films were deposited at room temperature on sapphire substrates and a rigorous analysis has been presented on the electrical and optical properties of the films as a function of Ag thickness. The optical and electrical properties were mainly controlled by the Ag mid-layer thickness of the TAT tri-layer. The TAT films showed high luminous transmittance 84% at 550 nm along with noteworthy low electrical resistance 3.65 × 10-5 Ω-cm and sheet resistance of 3.77 Ω/square, which is better are than those of amorphous ITO films and any sapphire-based dielectric/metal/dielectric multilayer stack. The carrier concentration of the films was increased with respect to Ag thickness. We obtained highest Hackke's figure of merit 43.97 × 10-3 Ω-1 from the TAT multilayer thin film with a 16 nm thick Ag mid-layer.

  4. MOVPE of InN films on GaN templates grown on sapphire and silicon(111) substrates

    International Nuclear Information System (INIS)

    Jamil, Muhammad; Arif, Ronald A.; Ee, Yik-Khoon; Tong, Hua; Tansu, Nelson; Higgins, John B.

    2008-01-01

    This paper reports the study of MOVPE of InN on GaN templates grown on sapphire and silicon(111) substrates. Thermodynamic analysis of MOVPE of InN performed using NH 3 as nitrogen source and the experimental findings support the droplet-free epitaxial growth of InN under high V/III ratios of input precursors. At a growth pressure of 500 Torr, the optimum growth temperature and V/III ratio of the InN film are 575-650 C and >3 x 10 5 , respectively. The surface RMS roughness of InN film grown GaN/sapphire template is ∝0.3 nm on 2 μm x 2 μm area, while the RMS roughness of the InN film grown on GaN/Si(111) templates is found as ∝0.7 nm. The X-ray diffraction (XRD) measurement reveals the (0002) texture of the InN film on GaN/sapphire template with a FWHM of 281 arcsec of the InN(0002) ω rocking curve. For the film grown on GaN/Si template under identical growth conditions, the XRD measurements show the presence of metallic In, in addition to the (0002) orientation of InN layer. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  5. The nucleation of HCl and Cl{sub 2}-based HVPE GaN on mis-oriented sapphire substrates

    Energy Technology Data Exchange (ETDEWEB)

    Bohnen, Tim; Dreumel, Gerbe W.G. van; Enckevort, Willem J.P. van; Ashraf, Hina; Jong, Aryan E.F. de; Hageman, Paul R.; Vlieg, Elias [IMM, Radboud University, Nijmegen (Netherlands); Weyher, Jan L. [Institute of High Pressure Physics, Polish Academy of Sciences, Warsaw (Poland)

    2010-07-15

    The nucleation of both classic HCl-based and novel Cl{sub 2{sup -}} based HVPE GaN on mis-oriented sapphire substrates was investigated. The use of Cl{sub 2}in HVPE increases the growth rate by a factor of 4-5 and strongly reduces the parasitic deposition, allowing for the growth of much thicker wafers than HCl-based HVPE. Morphological SEM surface studies of the HCl-based HVPE sample surface show that at 600 C a nanocrystalline layer is deposited on the sapphire. During the subsequent annealing phase, the morphology changes to a {mu}m-sized island structure. During overgrowth at 1080 C, the islands coalesce. Small voids or pinholes are then formed in between the coalescing GaN islands. These pinholes lead to numerous pits on the surface of the GaN at thicknesses of 5 {mu}m. The pits disappear during continued overgrowth and can no longer be found on the surface, when the GaN film reaches a thickness of 45 {mu}m. This particular coalescence mechanism also applies to Cl{sub 2}-based HVPE GaN on sapphire (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  6. Characterization of barium strontium titanate thin films on sapphire substrate prepared via RF magnetron sputtering system

    Science.gov (United States)

    Jamaluddin, F. W.; Khalid, M. F. Abdul; Mamat, M. H.; Zoolfakar, A. S.; Zulkefle, M. A.; Rusop, M.; Awang, Z.

    2018-05-01

    Barium Strontium Titanate (Ba0.5Sr0.5TiO3) is known to have a high dielectric constant and low loss at microwave frequencies. These unique features are useful for many electronic applications. This paper focuses on material characterization of BST thin films deposited on sapphire substrate by RF magnetron sputtering system. The sample was then annealed at 900 °C for two hours. Several methods were used to characterize the structural properties of the material such as X-ray diffraction (XRD) and atomic force microscopy (AFM). Field emission scanning electron microscopy (FESEM) was used to analyze the surface morphology of the thin film. From the results obtained, it can be shown that the annealed sample had a rougher surface and better crystallinity as compared to as-deposited sample.

  7. Micro-Structured Sapphire Fiber Sensors for Simultaneous Measurements of High-T and Dynamic Gas Pressure in Harsh Environments

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Hai [Clemson Univ., SC (United States); Tsai, Hai-Lung [Missouri Univ. of Science and Technology, Rolla, MO (United States); Dong, Junhang [Univ. of Cincinnati, OH (United States)

    2014-09-30

    This is the final report for the program “Micro-Structured Sapphire Fiber Sensors for Simultaneous Measurements of High Temperature and Dynamic Gas Pressure in Harsh Environments”, funded by NETL, and performed by Missouri University of Science and Technology, Clemson University and University of Cincinnati from October 1, 2009 to September 30, 2014. Securing a sustainable energy economy by developing affordable and clean energy from coal and other fossil fuels is a central element to the mission of The U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL). To further this mission, NETL funds research and development of novel sensor technologies that can function under the extreme operating conditions often found in advanced power systems. The main objective of this research program is to conduct fundamental and applied research that will lead to successful development and demonstration of robust, multiplexed, microstructured silica and single-crystal sapphire fiber sensors to be deployed into the hot zones of advanced power and fuel systems for simultaneous measurements of high temperature and gas pressure. The specific objectives of this research program include: 1) Design, fabrication and demonstration of multiplexed, robust silica and sapphire fiber temperature and dynamic gas pressure sensors that can survive and maintain fully operational in high-temperature harsh environments. 2) Development and demonstration of a novel method to demodulate the multiplexed interferograms for simultaneous measurements of temperature and gas pressure in harsh environments. 3) Development and demonstration of novel sapphire fiber cladding and low numerical aperture (NA) excitation techniques to assure high signal integrity and sensor robustness.

  8. Hematological profile variation in the european bison (Bison bonasus l., 1758 as a function of age, sex and health condition

    Directory of Open Access Journals (Sweden)

    Razvan Deju

    2011-12-01

    Full Text Available The paper analyzes some new hematological data on the European bison from the Natural Park of Vanatori Neamt, a comparison being made both between the values recorded in animals of different ages (2-8 years and sexes, and between the values of the European bison and those registered in some kindred ruminant mammals, such as the deer and the cow. More than that, a comparison is made between the data taken over from healthy bisons and from an animal affected by severe anemia and multiple parasitary indices. Hematological prosperity increases with the age in female bisons, while a decrease is reported in males, especially in the case of suffering animals, versus the healthy ones. Comparatively with other big mammals, the hematological profile of the bison is much more similar to that of domestic ruminants, being wholly different from that of the wild deer.

  9. Epitactical FeAl films on sapphire and their magnetic properties

    International Nuclear Information System (INIS)

    Trautvetter, Moritz

    2011-01-01

    In the presented thesis epitaxial FeAl thin films on sapphire have been prepared by pulse laser deposition (PLD). The thin films deposited at room temperature exhibits ferromagnetism and subsequent annealing is necessary to transform the thin films to paramagnetic B2-phase, where the transition temperature depends on the crystalline orientation of the sapphire substrate. Alternatively, by deposition at higher substrate temperature the B2-phase is obtained directly. However, morphology of the FeAl film is influenced by different growth modes resulting from different substrate temperatures. The paramagnetic FeAl films can then be transformed to ferromagnetic phase by successive ion irradiation. Independent of the ion species used for irradiation, the same universal relation between thin films' coercive fields and irradiation damage is identified. The ion irradiation ferromagnetism can be transformed back to paramagnetism by subsequent annealing. The mutual transition between ferromagnetic and paramagnetic phases has been performed several times and shows full reversibility. The ferromagnetic phase induced by Kr + irradiation exhibits structural relaxation, where the saturate magnetization of FeAl thin film gradually decreases in several days. Later, ion irradiation has been performed selectively on defined areas of the thin film with the help of an unconventional lithography technique. The subsequent thin film is composed of ordered hexagonal array of ferromagnetic nano-cylinders separated by a paramagnetic matrix, suggesting a promising system for magnetic data storage. (orig.)

  10. A Novel Method for Measurements of the Penetration Depth of MgB2 Superconductor Films by Using Sapphire Resonators with Short-Circuited Parallel Plates

    International Nuclear Information System (INIS)

    Jung, Ho Sang; Lee, J. H.; Cho, Y. H.; Lee, Sang Young; Seong, W. K.; Lee, N. H.; Kang, W. N.

    2009-01-01

    We introduce a measurement method that enables to measure the penetration depth(λ) of superconductor films by using a short-ended parallel plate sapphire resonator. Variations in the (λof MgB 2 films could be measured down to the lowest temperature using a sapphire resonator with a YBa 2 Cu 3 O 7-x film at the bottom. A model equation of λλ 0 [1-(T/T c ) τ ] -1/2 for MgB 2 films appeared to describe the observed variations of the resonant frequency of the sapphire resonator with temperature, with λ 0 , τ and T c used as the fitting parameters.

  11. Hematologic outcomes after total splenectomy and partial splenectomy for congenital hemolytic anemia☆☆☆

    Science.gov (United States)

    Englum, Brian R.; Rothman, Jennifer; Leonard, Sarah; Reiter, Audra; Thornburg, Courtney; Brindle, Mary; Wright, Nicola; Heeney, Matthew M.; Smithers, C. Jason; Brown, Rebeccah L.; Kalfa, Theodosia; Langer, Jacob C.; Cada, Michaela; Oldham, Keith T.; Scott, J. Paul; St Peter, Shawn D; Sharma, Mukta; Davidoff, Andrew M.; Nottage, Kerri; Bernabe, Kathryn; Wilson, David B.; Dutta, Sanjeev; Glader, Bertil; Crary, Shelley E.; Dassinger, Melvin S.; Dunbar, Levette; Islam, Saleem; Kumar, Manjusha; Rescorla, Fred; Bruch, Steve; Campbell, Andrew; Austin, Mary; Sidonio, Robert; Blakely, Martin L.; Rice, Henry E.

    2016-01-01

    Purpose The purpose of this study was to define the hematologic response to total splenectomy (TS) or partial splenectomy (PS) in children with hereditary spherocytosis (HS) or sickle cell disease (SCD). Methods The Splenectomy in Congenital Hemolytic Anemia (SICHA) consortium registry collected hematologic outcomes of children with CHA undergoing TS or PS to 1 year after surgery. Using random effects mixed modeling, we evaluated the association of operative type with change in hemoglobin, reticulocyte counts, and bilirubin. We also compared laparoscopic to open splenectomy. Results The analysis included 130 children, with 62.3% (n = 81) undergoing TS. For children with HS, all hematologic measures improved after TS, including a 4.1 g/dl increase in hemoglobin. Hematologic parameters also improved after PS, although the response was less robust (hemoglobin increase 2.4 g/dl, p < 0.001). For children with SCD, there was no change in hemoglobin. Laparoscopy was not associated with differences in hematologic outcomes compared to open. TS and laparoscopy were associated with shorter length of stay. Conclusion Children with HS have an excellent hematologic response after TS or PS, although the hematologic response is more robust following TS. Children with SCD have smaller changes in their hematologic parameters. These data offer guidance to families and clinicians considering TS or PS. PMID:26613837

  12. Relationship between lipid and hematological profiles with adiposity in obese adolescents.

    Science.gov (United States)

    Ferreira, Lisianny Camilla Cocri do Nascimento; da Silva, Humberto José Gomes; Lins, Tatiana Acioli; do Prado, Wagner Luiz

    2013-01-01

    An excess of weight including obesity have reached epidemic rates in all age groups, both in developed and developing countries. It is notable that overweight children and adolescents have a higher likelihood of becoming obese adults and to present health-related problems early in life. [corrected] To verify associations of the lipid and hematological profiles with adiposity in obese adolescents beginning multidisciplinary weight loss therapy. This cross-sectional study was conducted with 85 adolescents of both genders, aged 12-19 years (Tanner staging 3 or 4) and body mass index greater than the 95(th) percentile. The sum of the triceps, subscapular and calf skinfolds and the waist circumference were used to estimate adiposity. Blood samples were collected from all patients after overnight fasting to analyze blood lipids (total cholesterol, high-density lipoprotein, low-density lipoprotein, very low-density lipoprotein and triglycerides), blood sugar and the hematological profile (hemoglobin, platelets and red blood cells). The Kolmogorov-Smirnov test and Spearman and Pearson correlation coefficients were used for statistical analysis with significance set for p-values ≤ 0.05. There were statistical differences between genders for red blood cells (p-value = 0.000), hemoglobin (p-value = 0.000) and platelets (p-value = 0.002). Positive correlations were found for red blood cells (p-value = 0.031) and hemoglobin (p-value = 0.024) with waist circumference. There was a negative correlation between hemoglobin and the sum of skinfolds (p-value = 0.022). The results demonstrate an association between the lipid and hematological profiles and body adiposity in obese adolescents thus reinforcing the importance of treating obese adolescents early to prevent health related problems in adult life.

  13. Isotype-specific inhibition of the phosphatidylinositol-3-kinase pathway in hematologic malignancies

    Directory of Open Access Journals (Sweden)

    Castillo JJ

    2014-02-01

    Full Text Available Jorge J Castillo,1 Meera Iyengar,2 Benjamin Kuritzky,2 Kenneth D Bishop2 1Division of Hematologic Malignancies, Dana-Farber Cancer Institute, Boston, MA, 2Division of Hematology and Oncology, Rhode Island Hospital, Providence, RI, USA Abstract: In the last decade, the advent of biological targeted therapies has revolutionized the management of several types of cancer, especially in the realm of hematologic malignancies. One of these pathways, and the center of this review, is the phosphatidylinositol-3-kinase (PI3K pathway. The PI3K pathway seems to play an important role in the pathogenesis and survival advantage in hematologic malignancies, such as leukemia, lymphoma, and myeloma. The objectives of the present review, hence, are to describe the current knowledge on the PI3K pathway and its isoforms, and to summarize preclinical and clinical studies using PI3K inhibitors, focusing on the advances made in hematologic malignancies. Keywords: phosphatidylinositol-3-kinase pathway, inhibitors, leukemia, lymphoma, myeloma

  14. Hematological remission and long term hematological control of acute myeloblastic leukemia induced and maintained by granulocyte-colony stimulating factor (G-CSF) therapy.

    Science.gov (United States)

    Xavier, Luciana; Cunha, Manuel; Gonçalves, Cristina; Teixeira, Maria dos Anjos; Coutinho, Jorge; Ribeiro, António Carlos Pinto; Lima, Margarida

    2003-12-01

    We describe a case of a patient with CD34+, TdT+, CD13-, CD33-, MPO- undifferentiated acute leukemia who refused chemotherapy and who achieved complete hematological remission 14 months after the diagnosis, during a short course of granulocyte-colony stimulating factor (G-CSF) for neutropenia and life threatening infection. Relapse occurred approximately one year later and G-CSF was reintroduced, being maintained for 4 months, at a dose and frequency adapted to maintain normal blood counts, a complete hematological remission being achieved again. Five months after withdrawing the G-CSF therapy a second relapse was observed; G-CSF was tried again with success, resulting in a very good hematological response that was sustained by G-CSF maintenance therapy. One year latter there was the need of increasing the doses of G-CSF in order to obtain the same hematological effect, at same time blast cells acquired a more mature CD34+, TdT-, CD13+, CD33-, MPO+ myeloid phenotype. Finally, the patient developed progressive neutropenia, anemia, thrombocytopenia and acute leukemia in spite of G-CSF therapy, dying 64 months after initial diagnosis (50 months after starting G-CSF therapy) with overt G-CSF resistant acute myeloblastic leukemia (AML), after failure of conventional induction chemotherapy.

  15. Subspeciality training in hematology and oncology, 2003: results of a survey of training program directors conducted by the American Society of Hematology.

    Science.gov (United States)

    Todd, Robert F; Gitlin, Scott D; Burns, Linda J

    2004-06-15

    A survey of directors of adult and pediatric hematology/oncology subspecialty training programs in the United States and Canada was conducted to assess the environment in which recruitment and training is conducted in these medical disciplines. A total of 107 program directors responded to the survey, representing 66% of internal medicine and 47% of pediatric subspecialty programs in hematology or hematology/oncology. Specific areas covered in the web-based questionnaire included the type and demographics of the training program, profile of the training program director, characteristics of the applicant pool and existing trainee recruits, characteristics of the training program environment and curricula, research productivity of trainees, and the career pathways taken by recent training program graduates (including dominant areas of clinical interest). The results of this survey show considerable heterogeneity in the recruiting practices and the environment in which subspecialty training occurs, leading the authors to recommend improvements in or a heightened attention to issues, including recruitment of minority trainees, flexibility to recruit international medical school graduates, timing of trainee acceptance, maintaining the financial support of Medicare graduation medical education (GME), training of physician scientists, organization of the continuity clinic experience, visibility of nonmalignant hematology as a career path, and level of training program director support.

  16. Low-threshold stimulated emission at 249 nm and 256 nm from AlGaN-based multiple-quantum-well lasers grown on sapphire substrates

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiao-Hang; Detchprohm, Theeradetch; Kao, Tsung-Ting; Satter, Md. Mahbub; Shen, Shyh-Chiang; Douglas Yoder, P.; Dupuis, Russell D., E-mail: dupuis@gatech.edu [Center for Compound Semiconductors and School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0250 (United States); Wang, Shuo; Wei, Yong O.; Xie, Hongen; Fischer, Alec M.; Ponce, Fernando A. [Department of Physics, Arizona State University, Tempe, Arizona 85287-1504 (United States); Wernicke, Tim; Reich, Christoph; Martens, Martin; Kneissl, Michael [Technical University of Berlin, Institute for Solid State Physics, Berlin D-10623 (Germany)

    2014-10-06

    Optically pumped deep-ultraviolet (DUV) lasing with low threshold was demonstrated from AlGaN-based multiple-quantum-well (MQW) heterostructures grown on sapphire substrates. The epitaxial layers were grown pseudomorphically by metalorganic chemical vapor deposition on (0001) sapphire substrates. Stimulated emission was observed at wavelengths of 256 nm and 249 nm with thresholds of 61 kW/cm{sup 2} and 95 kW/cm{sup 2} at room temperature, respectively. The thresholds are comparable to the reported state-of-the-art AlGaN-based MQW DUV lasers grown on bulk AlN substrates emitting at 266 nm. These low thresholds are attributed to the optimization of active region and waveguide layer as well as the use of high-quality AlN/sapphire templates. The stimulated emission above threshold was dominated by transverse-electric polarization. This work demonstrates the potential candidacy of sapphire substrates for DUV diode lasers.

  17. Low-threshold stimulated emission at 249 nm and 256 nm from AlGaN-based multiple-quantum-well lasers grown on sapphire substrates

    International Nuclear Information System (INIS)

    Li, Xiao-Hang; Detchprohm, Theeradetch; Kao, Tsung-Ting; Satter, Md. Mahbub; Shen, Shyh-Chiang; Douglas Yoder, P.; Dupuis, Russell D.; Wang, Shuo; Wei, Yong O.; Xie, Hongen; Fischer, Alec M.; Ponce, Fernando A.; Wernicke, Tim; Reich, Christoph; Martens, Martin; Kneissl, Michael

    2014-01-01

    Optically pumped deep-ultraviolet (DUV) lasing with low threshold was demonstrated from AlGaN-based multiple-quantum-well (MQW) heterostructures grown on sapphire substrates. The epitaxial layers were grown pseudomorphically by metalorganic chemical vapor deposition on (0001) sapphire substrates. Stimulated emission was observed at wavelengths of 256 nm and 249 nm with thresholds of 61 kW/cm 2 and 95 kW/cm 2 at room temperature, respectively. The thresholds are comparable to the reported state-of-the-art AlGaN-based MQW DUV lasers grown on bulk AlN substrates emitting at 266 nm. These low thresholds are attributed to the optimization of active region and waveguide layer as well as the use of high-quality AlN/sapphire templates. The stimulated emission above threshold was dominated by transverse-electric polarization. This work demonstrates the potential candidacy of sapphire substrates for DUV diode lasers.

  18. HIV-associated hematologic malignancies: Experience from a Tertiary Cancer Center in India.

    Science.gov (United States)

    Reddy, Rakesh; Gogia, Ajay; Kumar, Lalit; Sharma, Atul; Bakhshi, Sameer; Sharma, Mehar C; Mallick, Saumyaranjan; Sahoo, Ranjit

    2016-01-01

    Data on HIV associated hematologic malignancies is sparse from India. This study attempts to analyze the spectrum and features of this disease at a tertiary cancer center in India. Retrospective study from case records of patients registered with a diagnosis of hematologic malignancy and HIV infection between January 2010 and June 2015. Thirteen cases of HIV associated hematologic malignancies were identified, six of them pediatric. HIV diagnosis was concurrent to diagnosis of cancer in 12 and preceded it in one of them. ECOG PS at presentation was >1 in all of them. All patients, except one, had B symptoms. Six of the patients had bulky disease and six are stage 4. Predominant extranodal disease was seen in 67% of them. NHL accounted for 10 of 13 patients and DLBCL-Germinal center was the most common subtype. Mean CD4+ cell count was 235/μL (range, 32-494). HAART could be given along with chemotherapy to 11 patients. Two-thirds of patients received standard doses of therapy. Chemo-toxicity required hospitalization in 58%. CR was achieved in 45% and 36% had progressive disease with first-line therapy. At the time of last follow up, 3 patients were alive with responsive disease, 2 in CR and 1 in PR. None of the pediatric patients were long time responders. These malignancies were of advanced stage and higher grade. Goal of therapy, in the HAART era, is curative. Pediatric patients had dismal outcome despite good chemotherapy and HAART. There is an urgent need to improve data collection for HIV related cancers in India.

  19. The effects of combination of Eurycoma longifolia Jack ethanolic extract and doxorubicine on hematological profile in rats given by 7,12-dimethylbenz(a)anthracene

    Science.gov (United States)

    Nurani, L. H.; Mursyidi, A.; Widyarini, S.; Rohman, A.

    2017-11-01

    Doxorubicin (Dox) is known as anticancer drug commonly used for cancer treatment. Eurycoma longifolia Jack or Pasakbumi was reported to have chemopreventive effect. In cancer patients, there are some dysfunctions of blood parameter, therefore some hematologic tests are needed to monitor cancer patients. In this study, the effects of combination of ethanolic extract of E. longifolia Jack (EEE) and Dox on hematologic profiles were investigated in rats injected by DMBA. Rats were divided into eight groups. Group I was normal group; Group II, rats were treated with extract dose 100 mg/kgbw; Groups III, IV, V, VI, VII and VIII, rats were treated with Dox, DMBA, DMBA+Dox, DMBA+EEE, DMBA+Dox +EEE, and Dox+EEE, respectively. DMBA administration orally was conducted twice a week for 5 weeks. At 16th week of treatments, bloods were taken from orbitalis sinus for hematologicals profile (levels of Hb, erytrocyte, hematocrite, leukocyte, MCV, MCH, and differencial leucocyte count) measurements. These data were analyzed by one way ANOVA followed by LSD test. DMBA administration significantly decreased the hematological profiles compared to the normal group, except in lymphocyte level. Rats treated with extract and extract+Dox were able to increase the hematological profile compared to rats given by DMBA only. Based on these findings it can be concluded that the combination of EEE and Dox potentially increase hematological profile of rats given by DMBA.

  20. Unusual ruby-sapphire transition in alluvial megacrysts, Cenozoic basaltic gem field, New England, New South Wales, Australia

    Science.gov (United States)

    Sutherland, Frederick L.; Graham, Ian T.; Harris, Stephen J.; Coldham, Terry; Powell, William; Belousova, Elena A.; Martin, Laure

    2017-05-01

    Rare ruby crystals appear among prevailing sapphire crystals mined from placers within basaltic areas in the New England gem-field, New South Wales, Australia. New England ruby (NER) has distinctive trace element features compared to those from ruby elsewhere in Australia and indeed most ruby from across the world. The NER suite includes ruby (up to 3370 ppm Cr), pink sapphire (up to 1520 ppm Cr), white sapphire (up to 910 ppm) and violet, mauve, purple, or bluish sapphire (up to 1410 ppm Cr). Some crystals show outward growth banding in this respective colour sequence. All four colour zones are notably high in Ga (up to 310 ppm) and Si (up to 1820 ppm). High Ga and Ga/Mg values are unusual in ruby and its trace element plots (laser ablation-inductively coupled plasma-mass spectrometry) and suggests that magmatic-metasomatic inputs were involved in the NER suite genesis. In situ oxygen isotope analyses (secondary ion mass spectrometry) across the NER suite colour range showed little variation (n = 22; δ18O = 4.4 ± 0.4, 2σ error), and are values typical for corundum associated with ultramafic/mafic rocks. The isolated NER xenocryst suite, corroded by basalt transport and with few internal inclusions, presents a challenge in deciphering its exact origin. Detailed consideration of its high Ga chemistry in relation to the known geology of the surrounding region was used to narrow down potential sources. These include Late Palaeozoic-Triassic fractionated I-type granitoid magmas or Mesozoic-Cenozoic felsic fractionates from basaltic magmas that interacted with early Palaeozoic Cr-bearing ophiolite bodies in the New England Orogen. Other potential sources may lie deeper within lower crust-mantle metamorphic assemblages, but need to match the anomalous high-Ga geochemistry of the New England ruby suite.

  1. Hematology of camelids.

    Science.gov (United States)

    Vap, Linda; Bohn, Andrea A

    2015-01-01

    Interpretation of camelid hematology results is similar to that of other mammals. Obtaining accurate results and using appropriate reference intervals can be a bit problematic, particularly when evaluating the erythron. Camelid erythrocytes vary from other mammals in that they are small, flat, and elliptical. This variation makes data obtained from samples collected from these species prone to error when using some automated instruments. Normal and abnormal findings in camelid blood are reviewed as well as how to ensure accurate results.

  2. Hematological findings in Noonan syndrome

    Directory of Open Access Journals (Sweden)

    Bertola Débora R.

    2003-01-01

    Full Text Available OBJECTIVE: Noonan syndrome is a multiple congenital anomaly syndrome, and bleeding diathesis is considered part of the clinical findings. The purpose of this study was to determine the frequency of hemostatic abnormalities in a group of Noonan syndrome patients. METHOD: We studied 30 patients with clinical diagnosis of Noonan syndrome regarding their hemostatic status consisting of bleeding time, prothrombin time, activated partial thromboplastin time and thrombin time tests, a platelet count, and a quantitative determination of factor XI. RESULTS: An abnormal laboratory result was observed in 9 patients (30%. Although coagulation-factor deficiencies, especially factor XI deficiency, were the most common hematological findings, we also observed abnormalities of platelet count and function in our screening. CONCLUSIONS: Hemostatic abnormalities are found with some frequency in Noonan syndrome patients (30% in our sample. Therefore, we emphasize the importance of a more extensive hematological investigation in these patients, especially prior to an invasive procedure, which is required with some frequency in this disorder.

  3. Pancytopenia: A clinico-hematological study

    Directory of Open Access Journals (Sweden)

    Fahim Manzoor

    2014-01-01

    Full Text Available Background: A review of both Western and Indian literature shows that there are few comprehensive studies on pancytopenia. In India, the causes of pancytopenia are not well defined. This data, if available, would help in planning the diagnostic and therapeutic approach in patients with pancytopenia. Aim: To evaluate the cases of pancytopenia by peripheral smear and/or bone marrow aspiration and/or bone marrow biopsy to find out the etiology, clinical, hematological, and histomorphologic features of pancytopenia. Materials and Methods: Detailed hematological investigations a complete hemogram, peripheral smear examination, bone marrow aspiration, and biopsy examination were done. Results: The most common cause of pancytopenia in our study was megaloblastic anemia (56%, followed by hypoplastic/aplastic anemia (14%, hypersplenism (8% and post viral illness (6%. Conclusion: Megaloblastic anemia due to vitamin B12/folate deficiency seems to reflect the higher prevalence of pancytopenia in Indian subjects, putting hypoplastic/aplastic anemia in the second position, which is the leading cause for pancytopenia in the Western countries.

  4. Refractive index of r-cut sapphire under shock pressure range 5 to 65 GPa

    International Nuclear Information System (INIS)

    Cao, Xiuxia; Li, Jiabo; Li, Jun; Li, Xuhai; Xu, Liang; Wang, Yuan; Zhu, Wenjun; Meng, Chuanmin; Zhou, Xianming

    2014-01-01

    High-pressure refractive index of optical window materials not only can provide information on electronic polarizability and band-gap structure, but also is important for velocity correction in particle-velocity measurement with laser interferometers. In this work, the refractive index of r-cut sapphire window at 1550 nm wavelength was measured under shock pressures of 5–65 GPa. The refractive index (n) decreases linearly with increasing shock density (ρ) for shock stress above the Hugoniot elastic limit (HEL): n = 2.0485 (± 0.0197) − 0.0729 (± 0.0043)ρ, while n remains nearly a constant for elastic shocks. This behavior is attributed to the transition from elastic (below HEL) to heterogeneous plastic deformation (above HEL). Based on the obtained refractive index-density relationship, polarizability of the shocked sapphire was also obtained

  5. Wetting phenomena of Al-Cu alloys on sapphire below 800 deg. C

    Energy Technology Data Exchange (ETDEWEB)

    Klinter, Andreas J., E-mail: andreas.klinter@mail.mcgill.ca [Mining and Materials Engineering, McGill University, M.H. Wong Building, 3610 University Street, Montreal, QC, H3A 2B2 (Canada); Leon-Patino, Carlos A. [Instituto de Investigaciones Metalurgicas, Universidad Michoacana de San Nicolas de Hidalgo, Apdo. Postal 888, CP 58000 Morelia, Michoacan (Mexico); Drew, Robin A.L. [Faculty of Engineering and Computer Science, Concordia University, 1455 Maisonneuve Blvd, EV 2.169, Montreal, QC, H3G 1M8 (Canada)

    2010-02-15

    Using a modified dispensed drop method, a decrease in contact angle on sapphire from pure aluminum to low-copper-containing Al alloys (7-12 wt.%) was found; with higher copper additions {theta} transitions to the non-wetting regime. Atomic force microscopy on long-term samples showed a significantly increased surface roughness beneath the drop. Using high-resolution transmission electron microscopy, the reaction product at the interface was identified as CuAl{sub 2}O{sub 4} for Al-7Cu and Al{sub 2}O{sub 3} for an Al-99.99 drop. X-ray photoelectron spectroscopy further confirmed the formation of CuAl{sub 2}O{sub 4} under CuAl{sub 2} drops. Spinel formation is caused by reaction of the alloy with residual oxygen in the furnace that is transported along the interface as modeled by thermodynamic simulations. The formation of CuAl{sub 2}O{sub 4} causes the reduced {sigma}{sub sl} and hence the improved wettability of sapphire by low-copper-containing alloys compared to pure aluminum. The main reason for the increase in {theta} with higher copper contents is the increasing {sigma}{sub lv} of the alloy.

  6. Properties of the generation of radiation in the near infrared part of the spectrum with a sapphire crystal laser having radiation-induced color centers

    International Nuclear Information System (INIS)

    Voitovich, A.P.; Grinkevich, V.E.; Kononov, V.A.; Kromskii, G.I.

    1986-01-01

    This paper investigates the spectral stability of the color centers in sapphire and the energy of lasers in which the active elements were colored with various techniques. Color centers were produced by neutron irradiation. The absorption spectra of the color centers are shown. The transformation of the spectra shows that the mutual conversions of color centers takes place during the thermal annealing of the sapphire; most of the color centers formed have luminescence. Generation or radiation with a tunable frequency was obtained in the case of transverse or quasi-longitudinal excitation by a ruby laser. The results show that ways for increasing the stability of the energy generated by a sapphire laser with color centers can be found

  7. Advances in Trace Element “Fingerprinting” of Gem Corundum, Ruby and Sapphire, Mogok Area, Myanmar

    Directory of Open Access Journals (Sweden)

    F. Lin Sutherland

    2014-12-01

    Full Text Available Mogok gem corundum samples from twelve localities were analyzed for trace element signatures (LA-ICP-MS method and oxygen isotope values (δ18O, by laser fluorination. The study augmented earlier findings on Mogok gem suites that suggested the Mogok tract forms a high vanadium gem corundum area and also identified rare alluvial ruby and sapphire grains characterised by unusually high silicon, calcium and gallium, presence of noticeable boron, tin and niobium and very low iron, titanium and magnesium contents. Oxygen isotope values (δ18O for the ruby and high Si-Ca-Ga corundum (20‰–25‰ and for sapphire (10‰–20‰ indicate typical crustal values, with values >20‰ being typical of carbonate genesis. The high Si-Ca-Ga ruby has high chromium (up to 3.2 wt % Cr and gallium (up to 0. 08 wt % Ga compared to most Mogok ruby (<2 wt % Cr; <0.02 wt % Ga. In trace element ratio plots the Si-Ca-Ga-rich corundum falls into separate fields from the typical Mogok metamorphic fields. The high Ga/Mg ratios (46–521 lie well within the magmatic range (>6, and with other features suggest a potential skarn-like, carbonate-related genesis with a high degree of magmatic fluid input The overall trace element results widen the range of different signatures identified within Mogok gem corundum suites and indicate complex genesis. The expanded geochemical platform, related to a variety of metamorphic, metasomatic and magmatic sources, now provides a wider base for geographic typing of Mogok gem corundum suites. It allows more detailed comparisons with suites from other deposits and will assist identification of Mogok gem corundum sources used in jewelry.

  8. The effect of a slight mis-orientation angle of c-plane sapphire substrate on surface and crystal quality of MOCVD grown GaN thin films

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong-Woo; Suzuki, Toshimasa [Nippon Institute of Technology, 4-1 Gakuendai, Miyashiro, Saitama, 345-8501 (Japan); Aida, Hideo [NAMIKI Precision Jewel Co. Ltd., 3-8-22 Shinden, Adachi-ku, Tokyo, 123-8511 (Japan)

    2004-09-01

    The effect of a slight mis-orientation of c-plane sapphire substrate on the surface morphology and crystal quality of GaN thin films grown by MOCVD has been investigated. The mis-orientation angle of vicinal c-plane sapphire substrate was changed within the range of 0.00(zero)-1.00(one) degree, and the experimental results were compared with those on just angle (zero degree) c-plane sapphire substrate. The surface morphology and crystal quality were found to be very sensitive to mis-orientation angle. Consequently, the mis-orientation angle was optimized to be 0.15 . (copyright 2004 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  9. Symptomatic splenic hamartoma with renal, cutaneous, and hematological abnormalities

    International Nuclear Information System (INIS)

    Kassarjian, A.; Patenaude, Y.G.; Bernard, C.; Bell, L.

    2001-01-01

    Background. There is a rare association between splenic hamartomas and hematological abnormalities with, to our knowledge, only 24 reported cases in the English literature. Patients and methods. We report a case of a splenic hamartoma in a 14-year-old boy associated with membranoproliferative glomerulonephritis, multiple lobular capillary hemangiomas of the skin, hypertension, and anemia. Following imaging with ultrasonography, MRI, and nuclear scans, a hamartoma was suspected, but malignancy could not be excluded. The lesion was removed by partial splenectomy, and pathological examination confirmed the presence of a red pulp splenic hamartoma. Results. The renal, hematological, and dermatological abnormalities resolved following removal of the splenic hamartoma. This is the first reported case of a splenic hamartoma associated with renal, cutaneous, and hematological abnormalities and only the second reported case of a symptomatic splenic hamartoma treated by partial splenectomy. (orig.)

  10. Symptomatic splenic hamartoma with renal, cutaneous, and hematological abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Kassarjian, A.; Patenaude, Y.G. [Dept. of Medical Imaging, Montreal Children' s Hospital, PQ (Canada); Bernard, C. [Dept. of Pathology, Montreal Children' s Hospital, PQ (Canada); Bell, L. [Dept. of Nephrology, Montreal Children' s Hospital, PQ (Canada)

    2001-02-01

    Background. There is a rare association between splenic hamartomas and hematological abnormalities with, to our knowledge, only 24 reported cases in the English literature. Patients and methods. We report a case of a splenic hamartoma in a 14-year-old boy associated with membranoproliferative glomerulonephritis, multiple lobular capillary hemangiomas of the skin, hypertension, and anemia. Following imaging with ultrasonography, MRI, and nuclear scans, a hamartoma was suspected, but malignancy could not be excluded. The lesion was removed by partial splenectomy, and pathological examination confirmed the presence of a red pulp splenic hamartoma. Results. The renal, hematological, and dermatological abnormalities resolved following removal of the splenic hamartoma. This is the first reported case of a splenic hamartoma associated with renal, cutaneous, and hematological abnormalities and only the second reported case of a symptomatic splenic hamartoma treated by partial splenectomy. (orig.)

  11. Femtosecond Ti:sapphire cryogenic amplifier with high gain and MHz repetition rate

    DEFF Research Database (Denmark)

    Dantan, Aurelien Romain; Laurat, Julien; Ourjoumtsev, Alexei

    2007-01-01

    We demonstrate high gain amplification of 160-femtosecond pulses in a compact double-pass cryogenic Ti:sapphire amplifier. The setup involves a negative GVD mirrors recompression stage, and operates with a repetition rate between 0.2 and 4 MHz with a continuous pump laser. Amplification factors a...... as high as 17 and 320 nJ Fourier-limited pulses are obtained at a 800 kHz repetition rate....

  12. Transformation of a Plane Wavefront in Hemispherical Lenses Made of Leuco-Sapphire

    Science.gov (United States)

    Vetrov, V. N.; Ignatenkov, B. A.; Yakobson, V. E.

    2018-01-01

    An algorithm for wavefront calculation of ordinary and extraordinary waves after propagation through hemispherical components made of a uniaxial crystal is developed. The influence of frequency dispersion of n o and n e , as well as change in the direction of the optic axis of the crystal, on extraordinary wavefront in hemispheres made of from leuco-sapphire and a plastically deformed analog thereof is determined.

  13. 16 CFR 23.23 - Misuse of the words “ruby,” “sapphire,” “emerald,” “topaz,” “stone,” “birthstone,” “gemstone,” etc.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Misuse of the words âruby,â âsapphire,â... PEWTER INDUSTRIES § 23.23 Misuse of the words “ruby,” “sapphire,” “emerald,” “topaz,” “stone,” “birthstone,” “gemstone,” etc. (a) It is unfair or deceptive to use the unqualified words “ruby,” “sapphire...

  14. Technical considerations for the use of CRISPR/Cas9 in hematology research.

    Science.gov (United States)

    Gundry, Michael C; Dever, Daniel P; Yudovich, David; Bauer, Daniel E; Haas, Simon; Wilkinson, Adam C; Singbrant, Sofie

    2017-10-01

    The hematopoietic system is responsible for transporting oxygen and nutrients, fighting infections, and repairing tissue damage. Hematopoietic system dysfunction therefore causes a range of serious health consequences. Lifelong hematopoiesis is maintained by repopulating multipotent hematopoietic stem cells (HSCs) that replenish shorter-lived, mature blood cell types. A prokaryotic mechanism of immunity, the Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR)/Cas9 nuclease system, has been recently "repurposed" to mutate mammalian genomes efficiently and in a sequence-specific manner. The application of this genome-editing technology to hematology has afforded new approaches for functional genomics and even the prospect of "correcting" dysfunctional HSCs in the treatment of serious genetic hematological diseases. In this Perspective, we provide an overview of three recent CRISPR/Cas9 methods in hematology: gene disruption, gene targeting, and saturating mutagenesis. We also summarize the technical considerations and advice provided during the May 2017 International Society of Experimental Hematology New Investigator Committee webinar on the same topic. Copyright © 2017 ISEH – Society for Hematology and Stem Cells. Published by Elsevier Inc. All rights reserved.

  15. Triploidy in the hematology of jundia juveniles (Siluriformes: Heptapteridae)

    OpenAIRE

    Fukushima, H; Bailone, RL; Weiss, LA; Martins, ML; Zaniboni-Filho, E

    2012-01-01

    This study compared the hematological characteristics of diploid and triploid of jundia, Rhamdia quelen juveniles, an important freshwater fish cultured in south Brazil. Hematological morphometry of erythrocytes were determined in blood smears under a light microscope. The blood was used to measure the number of red blood cells (RBC) with a hemocytometer Neubauer chamber, and the numbers of white blood cells (WBC) and thrombocytes that were obtained using an indirect method. The results showe...

  16. Hematologic studies of irradiated survivors in Hiroshima, Japan. Refractory anemia occurring in survivors of the atomic bombing in Nagasaki, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Yamasowa, Yoshimichi; Lange, R D; Wright, S W; Tomonaga, Masanobu; Kurasaki, Hirotami; Matsuoka, Shigeru; Matsunaga, Haruji

    1959-01-01

    This document contains 2 reports on the effects of radiation on the survivors of the atomic explosions in Hiroshima and Nagasaki. The first report is a hematologic survey conducted 33 to 44 months after the detonation of the atomic bomb in Hiroshima, Japan. The hematologic findings on a total of 824 survivors are compared with those on a control group of 1145 residents of Kure. Although statistical differences are apparent in the two groups, when one takes into account errors inherent in the hematologic methods themselves and differences in the possible incidence of parasitism and nutrition it would be unwarranted to attribute the slight changes found to radiation effect. The data presented here seem to indicate that radiation resulting from the explosion of the atomic bomb in Hiroshima, on August 6, 1945, has not significantly varied the hematologic values as analyzed in this report over a three-to four-year period. In the second report, the case histories of six Nagasaki atomic bomb survivors who developed refractory anemia are presented. Four of these individuals received undoubted radiation injury. The fact that refractory anemia may occur as a late manifestation of exposure to atomic radiation is pointed out. 15 references, 5 figures, 2 tables.

  17. Secondary electron emission of sapphire tungsten molybdenum and titanium for Maxwellian incident electrons

    International Nuclear Information System (INIS)

    Saussez-Hublet, M.-C.; Harbour, P.J.

    1980-06-01

    The second electron emission coefficient of various materials, namely titanium, molybdenum, tungsten and sapphire, has been calculated for a Maxwellian energy distribution from data for a normally incident monoenergetic beam of primary electrons. The most significant difference from the monoenergetic case occurs at low energies. In addition the influence of the incident angle of the electrons is discussed. (author)

  18. Feasibility study of white blood cell count in cerebrospinal fluid and hydrothorax and ascites with Sysmex ;XN-1000 hematology analyzer%SYSMEX XN-1000血球仪在脑脊液和胸腹水白细胞计数中的可行性探讨

    Institute of Scientific and Technical Information of China (English)

    叶小英; 范春丽; 陆敏; 卞洁

    2016-01-01

    Objective To analyze the feasibility of using body fluid module of Sysmex XN-1000 hematology analyzer for white blood cell count in the cerebrospinal fluid (CSF), hydrothorax and ascites. Methods Microscope method and Sysmex XN-1000 hematology analyzer were used to analyze 183 samples of CSF, hydrothorax and ascites at the same time. The measured results were divided into three groups:group A:0~1 000×106/L, B:1 001~5 000×106/L, C:>5 000×106/L. The results were statistically analyzed. Results Compared with the results of microscope, the results of Sysmex XN-1000 hematology analyzer showed no statistically significant difference (P>0.05). The correlation coeffi-cients of group A, B, C were 0.993, 0.984, 0.996, with the regression equation of y=1.007x-1.072, y=1.003+19.776x, y=1.241-1 419.365x, respectively. Conclusion The body fluid module of Sysmex XN-1000 hematology analyzer can be used for white blood cell count in clinical CSF and hydrothorax and ascites, with simple operation and reliable results. When the instrument is alarmed on the sample test, we should use manual microscopy review to improve the veracity and reliability of the results.%目的:探讨SYSMEX XN-1000血液分析仪(简称SYSMEX XN-1000)的体液模式在脑脊液和胸腹水白细胞计数中应用的可行性。方法分别采用手工显微镜镜检法和SYSMEX XN-1000对183例脑脊液和胸腹水标本进行白细胞计数,将所测结果按A:(0~1000)×106/L,B:(1001~5000)×106/L,C:>5000×106/L分为三组,分别进行统计学分析。结果与手工显微镜镜检法相比,SYSMEX XN-1000所测结果差异无统计学意义(P>0.05)。A、B、C三组的相关系数分别为0.993、0.984、0.996,A组回归方程为y=1.007x-1.072,B组回归方程为y=1.003x+19.776,C组回归方程为y=1.241x-1419.365。结论 SYSMEX XN-1000血液分析仪可用于临床脑脊液和胸腹水中白细胞计数,其操作简单易行,结果稳定可靠,但如果仪器进行样品检测时报警,应当手工镜检复核,以提高结果的准确性和可靠性。

  19. HEMATOLOGY, SERUM BIOCHEMISTRY, AND URINALYSIS VALUES IN THE ADULT GIANT PANDA ( AILUROPODA MELANOLEUCA).

    Science.gov (United States)

    Burrell, Caitlin; Zhang, Hemin; Li, Desheng; Wang, Chengdong; Li, Caiwu; Aitken-Palmer, Copper

    2017-12-01

    The giant panda ( Ailuropoda melanoleuca) is a high-profile threatened species with individuals in captivity worldwide. As a result of advances in captive animal management and veterinary medicine, the ex situ giant panda population is aging, and improved understanding of age-related changes is necessary. Urine and blood samples were collected in April and July 2015 and analyzed for complete blood count, serum biochemistry, and biochemical and microscopic urine analysis for all individuals sampled ( n = 7, 7-16 yr of age) from giant panda housed at the China Research and Conservation Centre for the Giant Panda in Bifengxia, Sichuan Province, China. Hematology and serum biochemistry values were similar to those previously reported for giant panda aged 2-20 yr and to Species360 (formerly International Species Information System) values. Urine was overall dilute (urine specific gravity range: 1.001-1.021), acellular, and acidic (pH range: 6-7). This is the first report of hematologic and serum biochemistry, with associated urinalysis values, in the giant panda aged 7-16 yr.

  20. Hematology, cytochemistry and ultrastructure of blood cells in fishing cat (Felis viverrina).

    Science.gov (United States)

    Prihirunkit, Kreangsak; Salakij, Chaleow; Apibal, Suntaree; Narkkong, Nual Anong

    2007-06-01

    Hematological, cytochemical and ultrastructural features of blood cells in fishing cat (Felis viverrina) were evaluated using complete blood cell counts with routine and cytochemical blood stains, and scanning and transmission electron microscopy. No statistically significant difference was found in different genders of this animal. Unique features of blood cells in this animal were identified in hematological, cytochemical and ultrastructural studies. This study contributes to broaden hematological resources in wildlife animals and provides a guideline for identification of blood cells in the fishing cat.

  1. Relationship between lipid and hematological profiles with adiposity in obese adolescents

    Directory of Open Access Journals (Sweden)

    Lisianny Camilla Cocri do Nascimento Ferreira

    2013-06-01

    Full Text Available Background: An excess of weight including obesity have reached epidemic rates in all age groups, both in developed and developing countries. It is notable that overweight children and adolescents have a higher likelihood of becoming obese adults and to present health-related problems early in life. Objetives: To verify associations of the lipid and hematological profiles with adiposity in obese adolescents beginning multidisciplinary weight loss therapy. Methods: This cross-sectional study was conducted with 85 adolescents of both genders, aged 12-19 years (Tanner staging 3 or 4 and body mass index greater than the 95th percentile. The sum of the triceps, subscapular and calf skinfolds and the waist circumference were used to estimate adiposity. Blood samples were collected from all patients after overnight fasting to analyze blood lipids (total cholesterol, high-density lipoprotein, low-density lipoprotein, very low-density lipoprotein and triglycerides, blood sugar and the hematological profile (hemoglobin, platelets and red blood cells. The Kolmogorov-Smirnov test and Spearman and Pearson correlation coefficients were used for statistical analysis with significance set for p-values ≤ 0.05. Results: There were statistical differences between genders for red blood cells (p-value = 0.000, hemoglobin (p-value = 0.000 and platelets (p-value = 0.002. Positive correlations were found for red blood cells (p-value = 0.031 and hemoglobin (p-value = 0.024 with waist circumference. There was a negative correlation between hemoglobin and the sum of skinfolds (p-value = 0.022. Conclusion: The results demonstrate an association between the lipid and hematological profiles and body adiposity in obese adolescents thus reinforcing the importance of treating obese adolescents early to prevent health related problems in adult life.

  2. An All-Solid-State High Repetiton Rate Titanium:Sapphire Laser System For Resonance Ionization Laser Ion Sources

    Science.gov (United States)

    Mattolat, C.; Rothe, S.; Schwellnus, F.; Gottwald, T.; Raeder, S.; Wendt, K.

    2009-03-01

    On-line production facilities for radioactive isotopes nowadays heavily rely on resonance ionization laser ion sources due to their demonstrated unsurpassed efficiency and elemental selectivity. Powerful high repetition rate tunable pulsed dye or Ti:sapphire lasers can be used for this purpose. To counteract limitations of short pulse pump lasers, as needed for dye laser pumping, i.e. copper vapor lasers, which include high maintenance and nevertheless often only imperfect reliability, an all-solid-state Nd:YAG pumped Ti:sapphire laser system has been constructed. This could complement or even replace dye laser systems, eliminating their disadvantages but on the other hand introduce shortcomings on the side of the available wavelength range. Pros and cons of these developments will be discussed.

  3. 21 CFR 864.9285 - Automated cell-washing centrifuge for immuno-hematology.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated cell-washing centrifuge for immuno... Establishments That Manufacture Blood and Blood Products § 864.9285 Automated cell-washing centrifuge for immuno-hematology. (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device used...

  4. Meeting the challenge of hematologic malignancies in sub-Saharan Africa

    Science.gov (United States)

    Wood, William A.; Lee, Stephanie J.; Shea, Thomas C.; Naresh, Kikkeri N.; Kazembe, Peter N.; Casper, Corey; Hesseling, Peter B.; Mitsuyasu, Ronald T.

    2012-01-01

    Cancer is a leading cause of death and disability in sub-Saharan Africa and will eclipse infectious diseases within the next several decades if current trends continue. Hematologic malignancies, including non-Hodgkin lymphoma, leukemia, Hodgkin lymphoma, and multiple myeloma, account for nearly 10% of the overall cancer burden in the region, and the incidence of non-Hodgkin lymphoma and Hodgkin lymphoma is rapidly increasing as a result of HIV. Despite an increasing burden, mechanisms for diagnosing, treating, and palliating malignant hematologic disorders are inadequate. In this review, we describe the scope of the problem, including the impact of endemic infections, such as HIV, Epstein-Barr virus, malaria, and Kaposi sarcoma–associated herpesvirus. We additionally describe current limitations in hematopathology, chemotherapy, radiotherapy, hematopoietic stem cell transplantation, and supportive care and palliation. We review contemporary treatment and outcomes of hematologic malignancies in the region and outline a clinical service and research agenda, which builds on recent global health successes combating HIV and other infectious diseases. Achieving similar progress against hematologic cancers in sub-Saharan Africa will require the sustained collaboration and advocacy of the entire global cancer community. PMID:22461494

  5. DCB - Cancer Immunology, Hematology, and Etiology Research

    Science.gov (United States)

    Part of NCI’s Division of Cancer Biology’s research portfolio, studies supported include the characterization of basic mechanisms relevant to anti-tumor immune responses and hematologic malignancies.

  6. Possibilities and tasks of ray hematology in the radiation treatment of mamma carcinomas

    International Nuclear Information System (INIS)

    Mozsa, Sz.

    1980-01-01

    The hematologic implications the ray treatment of mamma carcinomas are outlined. The main lines of the evolution of the problem, the causes of the increasing interest in radiation hematology as well as the pathophysiological bases of clinical phenomena are discussed. Also, the more detailed hematological clinical characteristics, the critical peripheric values, the problem of the local inactivation bone marrow dose, and finally, the problems of the cell reserves and the provocative methods are dealt with. Because of its theoretical importance the kinetic problems of the T/B-lymphocytes are discussed. The most important factors of the chemo and hormone therapy and the laboratory examinations and the principles of general radiation hematology are also reviewed. (N.I.)

  7. Performance of Ar+-milled Ti:Sapphire rib waveguides as single transverse-mode broadband fluorescence sources

    NARCIS (Netherlands)

    Grivas, C.; Shepherd, D.P.; May-Smith, T.C.; Eason, R.W.; Pollnau, Markus; Crunteanu, A.; Jelinek, M.

    2003-01-01

    Rib waveguides have been fabricated in pulsed-laser-deposited Ti:sapphire layers using photolithographic patterning and subsequent Ar+-beam milling. Fluorescence output powers up to 300 W have been observed from the ribs following excitation by a 3-W multiline argon laser. Mode intensity profiles

  8. Performance, immunity, serum biochemical and hematological ...

    African Journals Online (AJOL)

    ... results suggest that supplementing broilers' diet with 5 g/kg thyme can indicate favorable influences of antibiotic growth promoter on performance without any detrimental impacts on immune responses and blood parameters. Key words: Broiler, thyme, growth performance, immunity, serum biochemistry, hematology.

  9. High prevalence of malnutrition among patients with solid non-hematological tumors as found by using skinfold and circumference measurements

    Directory of Open Access Journals (Sweden)

    Adriana Garófolo

    Full Text Available CONTEXT AND OBJECTIVE: Malnutrition in cancer patients has many causes. Nutritional status is usually assessed from weight/height indices. These present limitations for the nutritional assessment of cancer patients: their weights include tumor mass, and lean mass changes are not reflected in weight/height indices. The objective was to evaluate differences between two anthropometric methods and compare deficits, in non-hematological tumor patients and hematological disease patients. DESIGN AND SETTING: Cross-sectional study at Instituto de Oncologia Pediátrica, Universidade Federal de São Paulo. METHODS: Children and adolescents were evaluated between March 1998 and January 2000. Traditional anthropometric measurements were obtained in the first month of treatment (induction therapy, by weight-for-height (W/H using z-scores index for children and body mass index (BMI for adolescents. Body composition evaluations consisted of specific anthropometric measurements: triceps skinfold thickness (TSFT, mid-upper arm circumference (MUAC and arm muscle circumference (AMC. Data were analyzed to compare nutritional assessment methods for diagnosing malnutrition prevalence. The chi-squared test was used for comparative analyses between tumor patients and hematological disease patients. RESULTS: Analysis was done on 127 patients with complete data. Higher percentages of deficits were found among tumor patients, by W/H z-scores or BMI and by MUAC and AMC. Higher percentages of deficits were shown by TSFT (40.2% and MUAC (35.4% than by W/H z-scores or BMI (18.9%. CONCLUSION: Non-hematological tumor patients presented higher malnutrition prevalence than did hematological disease patients. Body composition measurements by TSFT and MUAC detected more patients with malnutrition than did W/H or BMI.

  10. Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children.

    Science.gov (United States)

    Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Roh, Eun Youn; Chang, Ju Young

    2016-09-01

    Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age.

  11. Hematological Analysis of the Ascidian Botrylloides leachii (Savigny, 1816) During Whole-Body Regeneration.

    Science.gov (United States)

    Blanchoud, Simon; Zondag, Lisa; Lamare, Miles D; Wilson, Megan J

    2017-06-01

    Whole-body regeneration (WBR)-the formation of an entire adult from only a small fragment of its own tissue-is extremely rare among chordates. Exceptionally, in the colonial ascidian Botrylloides leachii (Savigny, 1816) a fully functional adult is formed from their common vascular system after ablation of all adults from the colony in just 10 d, thanks to their high blastogenetic potential. While previous studies have identified key genetic markers and morphological changes, no study has yet focused on the hematological aspects of regeneration despite the major involvement of the remaining vascular system and the contained hemocytes in this process. To dissect this process, we analyzed colony blood flow patterns using time-lapse microscopy to obtain a quantitative description of the velocity, reversal pattern, and average distance traveled by hemocytes. We also observed that flows present during regeneration are powered by temporally and spatially synchronized contractions of the terminal ampullae. In addition, we revised previous studies of B. leachii hematology as well as asexual development using histological sectioning and compared the role played by hemocytes during WBR. We found that regeneration starts with a rapid healing response characterized by hemocyte aggregation and infiltration of immunocytes, followed by increased activity of hemoblasts, recruitment of macrophage-like cells for clearing the tissues of debris, and their subsequent disappearance from the circulation concomitant with the maturation of a single regenerated adult. Overall, we provide a detailed account of the hematological properties of regenerating B. leachii colonies, providing novel lines of inquiry toward the decipherment of regeneration in chordates.

  12. CMOS Silicon-on-Sapphire RF Tunable Matching Networks

    Directory of Open Access Journals (Sweden)

    Chamseddine Ahmad

    2006-01-01

    Full Text Available This paper describes the design and optimization of an RF tunable network capable of matching highly mismatched loads to 50 at 1.9 GHz. Tuning was achieved using switched capacitors with low-loss, single-transistor switches. Simulations show that the performance of the matching network depends strongly on the switch performances and on the inductor losses. A 0.5 m silicon-on-sapphire (SOS CMOS technology was chosen for network implementation because of the relatively high-quality monolithic inductors achievable in the process. The matching network provides very good matching for inductive loads, and acceptable matching for highly capacitive loads. A 1 dB compression point greater than dBm was obtained for a wide range of load impedances.

  13. Eosinophilic pustular folliculitis associated with hematological disorders: A report of two cases and review of Japanese literature.

    Science.gov (United States)

    Takamura, Saori; Teraki, Yuichi

    2016-04-01

    Eosinophilic pustular folliculitis (EPF) occurs in patients with hematological disorders. However, clinical information about hematological disorder-associated EPF is scarce. We report two cases of EPF associated with mantle cell lymphoma and reviewed the available published work on Japanese cases. We identified a total of 23 Japanese cases, including the two cases reported here, who had hematological disorder-associated EPF. Fourteen cases were associated with treatment for hematological malignancies (transplantation-related EPF) and nine cases were associated with hematological malignancies themselves (hematological malignancy-related EPF). Although the skin eruption was clinically indistinguishable between the two subtypes, transplantation-related EPF occurred on the face and trunk of young and middle-aged men and women, whereas hematological malignancy-related EPF occurred mostly on the face of older men. Peripheral blood eosinophilia was more frequently observed in transplantation-related EPF. These observations suggest variations among patients with EPF associated with hematological disorders. © 2015 Japanese Dermatological Association.

  14. Effect of feeding cottonseed meal on some hematological and serum biochemical parameters in broiler birds

    Directory of Open Access Journals (Sweden)

    G. Thirumalaisamy

    2016-07-01

    Full Text Available Aim: The study was undertaken to find out the effect of feeding cottonseed meal (CSM on performance of hematological and serum biochemical parameters in broiler birds. Materials and Methods: A 6-week biological trial was carried out with 432-day-old Cobb 400 broiler chicks distributed to nine experimental diets with six replicates, each containing eight chicks. The experimental diets were formulated based on total amino acids (BTAA or based on digestible amino acids (BDAA with or without iron supplementation with two levels of CSM (2% and 4% and control diet based on maize – soybean. The whole blood was subjected to hematological studies. The serum samples were analyzed for protein fractions and lipid profiles. Results: The packed cell volume (PCV value, red blood cell (RBC numbers, and hemoglobin (Hb were lower in iron unsupplemented CSM BTAA or BDAA diets than the control (33.86-35.54 vs. 36.41%, 2.78-2.87 vs. 2.98 × 106/μl, and 10.30-10.70 vs. 10.88%. Supplementation of iron in CSM diets improved the PCV, RBC numbers, and Hb, and the values were comparable to the control. White blood cell numbers, mean corpuscular volume, mean corpuscular Hb (MCH, and MCH concentration values were comparable to the control. The erythrocyte osmotic fragility (EOF was poor in birds fed diets containing up to 4% CSM BTAA or CSM BDAA without iron supplementation (32.02-32.57 vs. 28.77%. Supplementation of iron improved the EOF. The serum cholesterol level did not change with or without iron supplementation. Conclusion: This study suggested that feeding of CSM BTAA or BDAA up to 4% level voiding iron supplementation lowers the hematological parameters, whereas supplementation of iron did not alter serum protein fractions and cholesterol profile; however, it had lowered some hematological parameters, which was rectified by iron supplementation.

  15. Telomere Shortening in Hematological Malignancies with Tetraploidization—A Mechanism for Chromosomal Instability?

    Directory of Open Access Journals (Sweden)

    Eigil Kjeldsen

    2017-11-01

    Full Text Available Aneuploidy, the presence of an abnormal number of chromosomes in a cell, is one of the most obvious differences between normal and cancer cells. There is, however, debate on how aneuploid cells arise and whether or not they are a cause or a consequence of tumorigenesis. Further, it is important to distinguish aneuploidy (the “state” of the karyotype from chromosomal instability (CIN; the “rate” of karyotypic change. Although CIN leads to aneuploidy, not all aneuploid cells exhibit CIN. One proposed route to aneuploid cells is through an unstable tetraploid intermediate because tetraploidy promotes chromosomal aberrations and tumorigenesis. Tetraploidy or near-tetraploidy (T/NT (81–103 chromosomes karyotypes with or without additional structural abnormalities have been reported in acute leukemia, T-cell and B-cell lymphomas, and solid tumors. In solid tumors it has been shown that tetraploidization can occur in response to loss of telomere protection in the early stages of tumorigenesis in colon cancer, Barrett’s esophagus, and breast and cervical cancers. In hematological malignancies T/NT karyotypes are rare and the role of telomere dysfunction for the induction of tetraploidization is less well characterized. To further our understanding of possible telomere dysfunction as a mechanism for tetrapolydization in hematological cancers we here characterized the chromosomal complement and measured the telomere content by interphase nuclei quantitative fluorescence in situ hybridization (iQFISH in seven hematological cancer patients with T/NT karyotypes, and after cytogenetic remission. The patients were identified after a search in our local cytogenetic registry in the 5-year period between June 2012 and May 2017 among more than 12,000 analyzed adult patients in this period. One advantage of measuring telomere content by iQFISH is that it is a single-cell analysis so that the telomere content can be distinguished between normal karyotype

  16. Origin for the shape of Au small crystals formed inside sapphire by ion implantation

    International Nuclear Information System (INIS)

    Ohkubo, M.; Hioki, T.

    1989-01-01

    In ion-implanted oxides, precipitation is usually formed except the case of forming solid solution. The precipitation comprises the metallic particles of implanted atoms, the oxide of implanted atoms, the metal of matrix elements, the compound of implanted atoms and matrix and so on. In particular, the metallic particles of implanted atoms are frequently faceted. From the facets, the equilibrium shape of crystals can be imagined. The equilibrium shape is determined so that the surface free energy is to be minimized. However, the shape of the metallic particles precipitated inside oxides should not be such equilibrium shape because they come in contact with foreign crystals. As the result, in the precipitation phenomena induced by ion implantation, the crystal structures of precipitated particles and substrates, the crystallographic relation between two crystals, interfacial energy and so on must be taken in consideration. In this paper, the report is made on the shape of the metallic gold particles formed inside sapphires by ion implantation that it was caused by only the crystal habit of sapphires regardless of the above-mentioned complexity. (K.I.)

  17. Bronchoscopic examinations for evaluating chest abnormal shadows associated with hematological disease

    International Nuclear Information System (INIS)

    Nakayama, Masayuki; Bando, Masashi; Kobayashi, Akira; Yamasawa, Hideaki; Ohno, Shoji; Sugiyama, Yukihiko

    2006-01-01

    Hematological diseases cause various respiratory complications, but their differentiation only by blood tests and chest radiology is often difficult. To clarify the characteristics of respiratory complications associated with hematological diseases and the diagnostic usefulness of bronchoscopic examinations for these complications, we clinically evaluated mainly underlying diseases, chest radiological findings, and bronchoscopic findings in 31 patients in whom we performed bronchoscopy for chest abnormal shadows associated with hematological disease during the past 13-year period. Among hematological disease, leukemia was most frequently observed, followed by malignant lymphoma and myelodysplastic syndrome. The most frequently observed chest CT findings were localized consolidation and diffuse Ground-glass opacity. Bronchoscopic examinations provided a definitive diagnosis in 20 patients (64.5%), and the most frequent diagnosis was pulmonary invasion by neoplastic cells (7 patients). Pulmonary invasion by neoplastic cells showed various images, and transbronchial lung biopsy : TBLB was useful for definitive diagnosis. After consideration of the general condition of patients and the risk of complications, bronchoscopy including TBLB should be performed when possible. (author)

  18. The risk of melanoma and hematologic cancers in patients with psoriasis.

    Science.gov (United States)

    Reddy, Shivani P; Martires, Kathryn; Wu, Jashin J

    2017-04-01

    The risk of melanoma and hematologic cancers in patients with psoriasis is controversial. We sought to assess the risk of melanoma and hematologic cancers in patients with psoriasis, and the association with different treatments. We used case-control and retrospective cohort designs to determine melanoma or hematologic cancer risk in patients with psoriasis. Risk with treatment type was assessed using Fisher exact test. Patients with psoriasis had 1.53 times greater risk of developing a malignancy compared with patients without psoriasis (P < .01). There were no significant differences in malignancy risk among patients treated with topicals, phototherapy, systemics, or biologic agents. Patients with psoriasis and malignancy did not have significantly worse survival than patients without psoriasis. It is possible that patients developed malignancy subsequent to the follow-up time included in the study. Patients with psoriasis may experience an elevated risk of melanoma and hematologic cancers, compared with the general population. The risk is not increased by systemic or biologic psoriasis therapies. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  19. Second Breakdown Susceptibility of Silicon-On-Sapphire Diodes having Systematically Different Geometries.

    Science.gov (United States)

    1980-05-30

    Sunshine’s experiments less enlight - ening than they might otherwise have been. First, changes in optical transmittance could not be correlated directly to...silicon- on-sapphire technology ) and the orientation of the silicon surface ex- posed to the oxide layer44 ,46 ,4 7,51. Not enough data were taken to at...success. With rapid progress of semi- conductor technology , such simplified and largely intuitive methods proved to be inadequate for dealing with

  20. Acoustic mismatch model and thermal phonon radiation across a tin/sapphire interface with radiation temperatures between 1.6 and 3.7 K

    International Nuclear Information System (INIS)

    Bayrle, R.; Weis, O.

    1989-01-01

    Using a special sandwich arrangement consisting of a constantan film, an insulating oxide layer and a superconducting tin-tunnel junction evaporated on an a-cut sapphire, the temperature jump between tin and sapphire has been measured as function of thermal phonon flux under steady-state and transient conditions using rectangular current pulses in the constantan heater. The tunnel junction serves as a very fast thermometer with a time resolution in the nanosecond range. During the steady-state and the heatup interval, full agreement is found between experimental results, and the predictions of the acoustic mismatch model applied to the phonon transfer across the tin/sapphire interface and under the additional assumption that thermal equilibrium exists between electrons and phonons (one-temperature model). In contrast, very strong deviations are found during the cooling process which starts immediately after the end of the heating pulses. This observed nonequilibrium between electron and phonon system is discussed in more detail in a subsequent paper

  1. Bacteremia and candidemia in hematological malignancies

    DEFF Research Database (Denmark)

    Hovgaard, D; Skinhøj, P; Bangsborg, Jette Marie

    1988-01-01

    171 episodes of bacteremia and candidemia in 142 patients were recorded during the period 1981-1985 in patients with hematological malignancies. Overall mortality, within 1 week of onset of bacteremia, was 20%. Increased mortality was found in patients with poor disease-prognosis (39%), with gran...

  2. Occupational health risk of working in garages: comparative study on blood pressure and hematological parameters between garage workers and Haramaya University community, Harar, eastern Ethiopia.

    Science.gov (United States)

    Ataro, Zerihun; Geremew, Abraham; Urgessa, Fekadu

    2018-01-01

    Occupational exposure to chemicals in garages causes a wide range of biological effects, depending upon the level and duration of exposure. In Ethiopia, there have been few studies conducted to assess the exposure of garage workers to chemicals. Preceding studies have not explored the effect of working in garage on blood pressure and hematological parameters. Therefore, this study aimed to assess differences in blood pressure and hematological parameters among garage workers compared to the Haramaya University community, Harar, eastern Ethiopia. A comparative cross-sectional study was conducted in Harar town, eastern Ethiopia. Thirty garage workers were selected and compared with 30 age- and sex-matched controls comprising of teachers and students. Demographic and occupational data were collected by using a structured questionnaire by a trained data collector. Blood pressure was measured using sphygmomanometry. Hematological parameters were measured with an automated hematology analyzer. Data were analyzed using Stata version 13. The majority of the garage workers did not implement effective preventive or control measures for workplace chemical exposure. Statistically significant increases were found in systolic (128.67±18.14 vs 106.33 ±9.27 mmHg, P workers compared to the control group. On the other hand, statistically significant decreases were found in red blood cells (5.13±0.38 vs 5.46±0.36×10 12 cells/L, P =0.0006), hemoglobin (14.89±0.71 vs 15.45±0.87 g/dL, P =0.0062), hematocrit (43.98%±1.99% vs 46.4%3±2.32%, P workers compared to the control group. There were significant differences in blood pressure and hematological parameters between garage workers and the control group. Therefore, appropriate and effective safety measures need to be taken by the workers to prevent possible chemical exposure during routine tasks.

  3. Intracavity doubling of CW Ti:sapphire laser to 392.5 nm using BiBO-crystal

    DEFF Research Database (Denmark)

    Mortensen, Jesper Liltorp; Thorhauge, Morten; Tidemand-Lichtenberg, Peter

    2005-01-01

    In this work we present results obtained for intra-cavity frequency-doubling of a 785 nm CW Ti:sapphire laser utilising BiBO as the non-linear crystal. Intracavity doubling offers several advantages compared to extra-cavity doubling, such as no need to couple to an external resonance cavity...

  4. Resources for Hematology On and Off the Web.

    Science.gov (United States)

    Sebald-Kinder, Shirley; Petty, Janet L

    2017-09-01

    Searching the literature can be challenging because of the large volume of information. It can be time consuming to locate and determine what evidence will provide the best health outcomes for patients. In addition, locating hematology information for patients and family members is one of the most challenging of all health care topics. Hematology can be technical and difficult for most people to understand, especially for those with little or no science background and poor reading skills. This article provides guidance on how and where to locate information to address the needs of both clinicians and patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Invasive fungal diseases in children with hematologic disorders

    Directory of Open Access Journals (Sweden)

    Ünsal Günay

    2009-12-01

    Full Text Available Objective: Fungal infection is a significant problem, causing of infective deaths of leukemic patients. The situation in developing countries is not well documented. The purpose of this study was characterizing IFD by analyzing data retrospectively to determine the incidence, predisposing factors, diagnostic methods, efficacy of treatment, and the outcome in pediatric patients with hematological disorders. Materials and Methods: There were 160 children with leukemia (22 AML, 129 ALL and 9 with aplastic anemia (AA. The diagnostic criteria for IFD were defined according to the EORTC/MSG, 2008. IFD was classified as proven or probable. Empiric antifungal treatment with L-AmB was commenced by day 5-7 of persistent fever. Patients with invasive aspergillosis (IA who were refractory to primary treatment were commenced on voriconazole (VCZ. Salvage therapy as combination of VCZ and caspofungin was given to those with progressive infection. Results: The incidence of IFD was found 23 (14.3%. 19 with leukemia (14 ALL, 5 AML and 4 with aplastic anemia were diagnosed as IFD. IA was the dominant cause of infection (n=17 and the rest (n: 6 had candidiasis. Ten children had “proven” infection and 13 children were defined as “probable”. The most frequent site of infection was lungs. In our series, the most frequently used diagnostic methods were clinical findings (100% and radiologic methods (84%. The success rate of treatment for candidiasis and IA were found 60%, 71% respectively. IFD related death rate was found 30%.Conclusion: IFD is still a major morbidity and mortality reason in children with hematologic disorders. However, the availability of new antifungal treatments and diagnostic tests will improve the survival rates in these children.

  6. Should a clinical rotation in hematology be mandatory for undergraduate medical students?

    Directory of Open Access Journals (Sweden)

    Mandan J

    2016-09-01

    Full Text Available Jay Mandan,1 Harmeet Singh Sidhu,1 Adil Mahmood2 1Faculty of Medicine, Imperial College London, London, UK; 2Faculty of Life Sciences and Medicine, King’s College London, London, UK Abstract: Clinical rotations form the foundation of medical education. Medical students in the UK are offered conventional rotations such as cardiology, surgery, and psychiatry as part of their undergraduate curriculum, but a rotation in hematology is not currently mandatory. This paper explores the benefits of a compulsory hematology rotation, and suggests recommendations for its implementation in UK medical school curricula. Keywords: medical education, clinical rotations, hematology

  7. Large scale metal-free synthesis of graphene on sapphire and transfer-free device fabrication.

    Science.gov (United States)

    Song, Hyun Jae; Son, Minhyeok; Park, Chibeom; Lim, Hyunseob; Levendorf, Mark P; Tsen, Adam W; Park, Jiwoong; Choi, Hee Cheul

    2012-05-21

    Metal catalyst-free growth of large scale single layer graphene film on a sapphire substrate by a chemical vapor deposition (CVD) process at 950 °C is demonstrated. A top-gated graphene field effect transistor (FET) device is successfully fabricated without any transfer process. The detailed growth process is investigated by the atomic force microscopy (AFM) studies.

  8. Frictional interactions in forming processes: New studies with transparent sapphire strip-drawing dies

    Science.gov (United States)

    Rao, R. S.; Lu, C. Y.; Wright, P. K.; Devenpeck, M. L.; Richmond, O.; Appleby, E. J.

    1982-05-01

    This research is concerned with the frictional interactions at the toolwork interfaces in the machining and strip-drawing processes. A novel feature is that transparent sapphire (single crystal Al2O3) is being used as the tool and die material. This allows the tribological features of the interface to be directly observed and recorded on movie-film. These qualitative studies provide information on the role of lubricants. In addition, techniques are being developed to quantify the velocity gradient along the interface. For example, in the drawing work it has been found that tracer markings (e.g. dye-spots), applied to the undrawn strip, remain intact during drawing and can be tracked along the sapphire/strip interface. Such data will be used as input to a finite-element, elasto-plastic-workhardening model of the deformation process. The latter can compute strip deformation characteristics, drawing forces and local coefficients of friction at the interface. Introductory results will be presented in this paper, obtained from drawing tin-plated mild steel with sapphire and cemented carbide dies. Drawing loads and die-separating forces will be presented and movie-films of the action of tracer markings at the interface shown. In order to demonstrate how this data can be used in an analysis of a large strain deformation process with friction, initial results from running the FIPDEF elasto-plastic code will be discussed. From a commercial viewpoint research on strip-drawing is of special interest to the can-making industry. From a physical viewpoint stripdrawing is of particular interest because it is a symmetrical, plane strain deformation and, in comparison with other metal processing operations, it is more readily modeled. However, until now the elasto-plastic codes that have been developed to predictively model drawing have had limitations: the most notable being that of quantifying the friction conditions at the die-work interface. Hence the specification of the

  9. Crystal Structure and Ferroelectric Properties of ε-Ga2O3 Films Grown on (0001)-Sapphire.

    Science.gov (United States)

    Mezzadri, Francesco; Calestani, Gianluca; Boschi, Francesco; Delmonte, Davide; Bosi, Matteo; Fornari, Roberto

    2016-11-21

    The crystal structure and ferroelectric properties of ε-Ga 2 O 3 deposited by low-temperature MOCVD on (0001)-sapphire were investigated by single-crystal X-ray diffraction and the dynamic hysteresis measurement technique. A thorough investigation of this relatively unknown polymorph of Ga 2 O 3 showed that it is composed of layers of both octahedrally and tetrahedrally coordinated Ga 3+ sites, which appear to be occupied with a 66% probability. The refinement of the crystal structure in the noncentrosymmetric space group P6 3 mc pointed out the presence of uncompensated electrical dipoles suggesting ferroelectric properties, which were finally demonstrated by independent measurements of the ferroelectric hysteresis. A clear epitaxial relation is observed with respect to the c-oriented sapphire substrate, with the Ga 2 O 3 [10-10] direction being parallel to the Al 2 O 3 direction [11-20], yielding a lattice mismatch of about 4.1%.

  10. Protective role of Carica papaya (Linn.) in electron beam radiation induced hematological and cytogenetic damages in Swiss albino mice

    International Nuclear Information System (INIS)

    Yogish Somayaji, T.; Suchetha Kumari, N.

    2014-01-01

    Carica papaya (Linn.) is known to possess various biomedical applications. It has remarkable antioxidant properties. The main objective of the study was to evaluate the leaf extracts of Carica papaya (Linn.) on hematologic and cytogenetic changes occurring due to irradiation of mice to sub-lethal doses of Electron Beam Radiation (EBR). Analysis of hematological changes occurring due to irradiation of mice to sub-lethal doses of EBR, and the effects of Carica papaya (Linn.) extract on the same. The Assessment of hematopoietic stress by spleen colony forming unit and spleen body weight index. The analysis of cell proliferation and immunomodulation with response to the effects of Carica papaya (Linn.) extract by estimation of IL-6. The estimation of serum total antioxidants, lipid peroxidation and analyzing the activities of enzymes like SOD, ALP, and AST. Male Swiss albino mice were fed orally with papaya aqueous leaf extract for 15 days. They were irradiated with a whole body dose of 6 Gy Electron Beam radiation. The mice were dissected for liver, kidney, bone marrow, spleen and brain. The hematological studies were done using blood cell count in an automated cell counter. The biochemical estimations like urea, creatinine, SGOT, SGPT, Total Protein, Albumin, Bilirubin were done using the serum and homogenates. The total antioxidant capacity, the antioxidant enzymes were estimated. The Interleukin-6 levels were estimated in serum to assess immune modulation. The results show a decrease in the hematological parameters in radiated animals. The papaya treated groups have shown modulation in the hematological parameters. The extract has also reduced the suppression of the bone marrow induced by radiation. The radiation induced liver damage is also reduced in papaya treated groups. The aqueous extract of Carica papaya (Linn.) has shown protective effects in electron beam radiation induced tissue damages in Swiss Albino mice (author)

  11. EVALUATION OF HEMATOLOGY AND BIOCHEMICAL PARAMETERS OF FREE-LIVING EUROPEAN BROWN HARE

    Directory of Open Access Journals (Sweden)

    Miriam Trusinová

    2012-12-01

    Full Text Available The objective of our study was to determine blood hematological and serum chemistry values for a population of free-living European brown hares and to investigate differences related to age. The European brown hare (Lepus europaeus is a species of hare naturally occurring in northern, central and western parts of Europe and southwestern Asia. The blood samples were collected from 25 hares (15 adults and 10 juveniles shot during regular hunting seasons in 4 hunting grounds located in Danube lowland. Following parameters were analyzed: WBC, LYM, GRA, RBC, HGB, HCT, MCV, MCH, MCHC on blood samples, and glucose, total proteins, urea, bilirubin, cholesterol, Ca, P, Na, K, Cl on serum. WBC count was higher in adults (2.86.109.l-1 than in young hares (2.71.109.l-1. RBC count and HGB concentration were higher in young hares (RBC=8.94.1012.l-1, HGB=184.43 g.l-1 than in adults (RBC=8.38.1012.l-1, HGB=177.59 g.l-1. No significant differences were found in other hematology parameters. Biochemical indicators of age were evaluated and an increased content of glucose in adult individuals was found (a = 9.39 mmol.l-1, j = 8.48 mmol.l-1. The increased level of urea in blood serum was observed as almost significant in juvenile individuals (a = 6.11 mmol.l-1, j = 6.94 mmol.l-1, but also reduction of bilirubin was observed (a = 5.19 mmol.l-1, j = 4.23 mmol.l-1. Other monitored biochemical parameters were fairly balanced. All evaluated hematology and serum chemistry parameters of brown hares were within the physiological range with relatively low differences.

  12. Hematology of Nile tilapia (Oreochromis niloticus subjected to anesthesia and anticoagulation protocols

    Directory of Open Access Journals (Sweden)

    Nadia Cristine Weinert

    2015-12-01

    Full Text Available Clinical hematology facilitates the diagnosis of disease and can act as a prognostic indicator of pathological conditions in fish. The aim of the present study was to evaluate hematological parameters of Nile tilapia (Oreochromis niloticus subjected to different anesthetics and anticoagulants. Thirty apparently healthy fishes (average weight of 473 ± 35. 50 g and mean total length of 29. 33 ± 0. 37 cm, were selected from the local commercial fish farm in the Lages municipality (Santa Catarina, Brazil. The animals were randomly divided into three groups of 10. In two groups, anesthesia was induced with eugenol (70 mg·L- 1 (EG and Benzocaine hydrochloride (100 mg·L-1 (BG, respectively. Anesthesia was not administered to fish of the third group (CG/control group. Blood samples were obtained by venipuncture of the caudal vessels and placed into microtubes containing sodium heparin or Na2EDTA for further analysis. The results were analyzed by Sigma Stat for Windows, the paired t-test for significant differences between anticoagulants of the same group, and analysis of variance followed by the Tukey test for comparison of means between groups (p ? 0. 05. Most of the observed changes in the erythrogram were significantly higher for the anticoagulant heparin and benzocaine group in comparison to the control group. However, the values obtained for the leukogram were significantly higher for all groups subjected to the Na2EDTA anticoagulant, suggesting that heparin may cause cell clumping. The results suggest that the anesthetics under investigation effectively minimizes the effects of stress caused by handling and invasive procedures, and that the anticoagulant heparin causes less hemolysis in comparison to Na2EDTA for Nile tilapia. Thus, the hematological variations attributed to different anesthetic protocols and/or different anticoagulants should be considered for the species Oreochromis niloticus.

  13. Hematological and Molecular Characterization of Hb J-Buda [α61(E10)Lys → Asn, AAG > AAT].

    Science.gov (United States)

    Panyasai, Sitthichai; Permsripong, Nopphadol; Jaiping, Kanokwan; Khantarag, Pisuttinee; Pornprasert, Sakorn

    2016-06-01

    Hemoglobin (Hb) J-Buda [α61(E10)Lys → Asn, AAG > AAT] is a very rare α-chain variant found in South-East Asia. We analyzed hematological parameters and provided a rapid molecular analysis method for detection of this hemoglobinopathy in two Thai women who had severe microcytic anemia with Hb and MCV AAG → AAT mutation at codon 61 for Hb J-Buda on one allele of the α1-globin gene. The developed Allele-specific PCR (ASPCR) showed the 455 bp amplified fragment from Hb J-Buda allele. Thus, understanding of hematological characterizations and the developed ASPCR for diagnosis of Hb J-Buda are essential for genetic counseling of this hemoglobinopathy.

  14. Effect of Administration of Withania somnifera on Some Hematological and Immunological Profile of Broiler Chicks

    Directory of Open Access Journals (Sweden)

    Muhammad Mushtaq*, F. R. Durrani, N. Imtiaz, Umer Sadique1, A. Hafeez, S. Akhtar2 and S. Ahmad3

    2012-01-01

    Full Text Available This study was conducted to assess the performance of broiler chickens based on some hematological and immunological profile, upon inclusion of aqueous extract of Withania somnifera (W. somnifera in their drinking water. For this purpose, 240 a-day-old broiler chicks were purchased from a local hatchery and divided into four groups i.e. WST-0, WST-I, WST-II and WST-III. Group WST-0 was kept as control, while chicks in group WST-I, WST-II and WST-III were offered in their drinking water with an extract of W. somnifera at 10, 20 and 30g/L for 35 days, starting from day 1 of age. Feed intake and body weight were recorded on regular basis and hematological and immunological profile of the birds was analyzed at the end of experiment. Administration of W. somnifera extract resulted in significantly higher feed intake and body weight of birds in all treated groups. An increase in the values of Hb, PCV and TLC was noted in the treatment groups. A non significant difference was noted in the counts of neutrophils, lymphocytes, eosinophils and monocytes in all treatment groups as compared to control. Antibodies titers against IB and IBD were significantly higher in all treatment groups as compare to the values shown by the chicks in control group. Findings of this study indicated that administration of W. somnifera extract to broiler chicks improve their feed intake, body weight gain, hematological profile and immunological status.

  15. Evaluation of cell count and classification capabilities in body fluids using a fully automated Sysmex XN equipped with high-sensitive Analysis (hsA) mode and DI-60 hematology analyzer system.

    Science.gov (United States)

    Takemura, Hiroyuki; Ai, Tomohiko; Kimura, Konobu; Nagasaka, Kaori; Takahashi, Toshihiro; Tsuchiya, Koji; Yang, Haeun; Konishi, Aya; Uchihashi, Kinya; Horii, Takashi; Tabe, Yoko; Ohsaka, Akimichi

    2018-01-01

    The XN series automated hematology analyzer has been equipped with a body fluid (BF) mode to count and differentiate leukocytes in BF samples including cerebrospinal fluid (CSF). However, its diagnostic accuracy is not reliable for CSF samples with low cell concentration at the border between normal and pathologic level. To overcome this limitation, a new flow cytometry-based technology, termed "high sensitive analysis (hsA) mode," has been developed. In addition, the XN series analyzer has been equipped with the automated digital cell imaging analyzer DI-60 to classify cell morphology including normal leukocytes differential and abnormal malignant cells detection. Using various BF samples, we evaluated the performance of the XN-hsA mode and DI-60 compared to manual microscopic examination. The reproducibility of the XN-hsA mode showed good results in samples with low cell densities (coefficient of variation; % CV: 7.8% for 6 cells/μL). The linearity of the XN-hsA mode was established up to 938 cells/μL. The cell number obtained using the XN-hsA mode correlated highly with the corresponding microscopic examination. Good correlation was also observed between the DI-60 analyses and manual microscopic classification for all leukocyte types, except monocytes. In conclusion, the combined use of cell counting with the XN-hsA mode and automated morphological analyses using the DI-60 mode is potentially useful for the automated analysis of BF cells.

  16. Hematological Toxicity After Robotic Stereotactic Body Radiosurgery for Treatment of Metastatic Gynecologic Malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Kunos, Charles A., E-mail: charles.kunos@UHhospitals.org [Department of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Debernardo, Robert [Department of Obstetrics and Gynecology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Radivoyevitch, Tomas [Department of Epidemiology and Biostatistics, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Fabien, Jeffrey; Dobbins, Donald C.; Zhang Yuxia; Brindle, James [Department of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States)

    2012-09-01

    Purpose: To evaluate hematological toxicity after robotic stereotactic body radiosurgery (SBRT) for treatment of women with metastatic abdominopelvic gynecologic malignancies. Methods and Materials: A total of 61 women with stage IV gynecologic malignancies treated with abdominopelvic SBRT were analyzed after ablative radiation (2400 cGy/3 divided consecutive daily doses) delivered by a robotic-armed Cyberknife SBRT system. Abdominopelvic bone marrow was identified using computed tomography-guided contouring. Fatigue and hematologic toxicities were graded by retrospective assignment of common toxicity criteria for adverse events (version 4.0). Bone marrow volume receiving 1000 cGy (V10) was tested for association with post-therapy (median 32 days [25%-75% quartile, 28-45 days]) white- or red-cell counts, hemoglobin levels, and platelet counts as marrow toxicity surrogates. Results: In all, 61 women undergoing abdominopelvic SBRT had a median bone marrow V10 of 2% (25%-75% quartile: 0%-8%). Fifty-seven (93%) of 61 women had received at least 1 pre-SBRT marrow-taxing chemotherapy regimen for metastatic disease. Bone marrow V10 did not associate with hematological adverse events. In all, 15 grade 2 (25%) and 2 grade 3 (3%) fatigue symptoms were self-reported among the 61 women within the first 10 days post-therapy, with fatigue resolved spontaneously in all 17 women by 30 days post-therapy. Neutropenia was not observed. Three (5%) women had a grade 1 drop in hemoglobin level to <10.0 g/dL. Single grade 1, 2, and 3 thrombocytopenias were documented in 3 women. Conclusions: Abdominopelvic SBRT provided ablative radiation dose to cancer targets without increased bone marrow toxicity. Abdominopelvic SBRT for metastatic gynecologic malignancies warrants further study.

  17. Hematological Toxicity After Robotic Stereotactic Body Radiosurgery for Treatment of Metastatic Gynecologic Malignancies

    International Nuclear Information System (INIS)

    Kunos, Charles A.; Debernardo, Robert; Radivoyevitch, Tomas; Fabien, Jeffrey; Dobbins, Donald C.; Zhang Yuxia; Brindle, James

    2012-01-01

    Purpose: To evaluate hematological toxicity after robotic stereotactic body radiosurgery (SBRT) for treatment of women with metastatic abdominopelvic gynecologic malignancies. Methods and Materials: A total of 61 women with stage IV gynecologic malignancies treated with abdominopelvic SBRT were analyzed after ablative radiation (2400 cGy/3 divided consecutive daily doses) delivered by a robotic-armed Cyberknife SBRT system. Abdominopelvic bone marrow was identified using computed tomography-guided contouring. Fatigue and hematologic toxicities were graded by retrospective assignment of common toxicity criteria for adverse events (version 4.0). Bone marrow volume receiving 1000 cGy (V10) was tested for association with post-therapy (median 32 days [25%-75% quartile, 28-45 days]) white- or red-cell counts, hemoglobin levels, and platelet counts as marrow toxicity surrogates. Results: In all, 61 women undergoing abdominopelvic SBRT had a median bone marrow V10 of 2% (25%-75% quartile: 0%-8%). Fifty-seven (93%) of 61 women had received at least 1 pre-SBRT marrow-taxing chemotherapy regimen for metastatic disease. Bone marrow V10 did not associate with hematological adverse events. In all, 15 grade 2 (25%) and 2 grade 3 (3%) fatigue symptoms were self-reported among the 61 women within the first 10 days post-therapy, with fatigue resolved spontaneously in all 17 women by 30 days post-therapy. Neutropenia was not observed. Three (5%) women had a grade 1 drop in hemoglobin level to <10.0 g/dL. Single grade 1, 2, and 3 thrombocytopenias were documented in 3 women. Conclusions: Abdominopelvic SBRT provided ablative radiation dose to cancer targets without increased bone marrow toxicity. Abdominopelvic SBRT for metastatic gynecologic malignancies warrants further study.

  18. Morphologic and cytochemical characteristics of blood cells and hematologic and plasma biochemical reference ranges in green iguanas.

    Science.gov (United States)

    Harr, K E; Alleman, A R; Dennis, P M; Maxwell, L K; Lock, B A; Bennett, R A; Jacobson, E R

    2001-03-15

    To determine blood cell morphologic characteristics and hematologic and plasma biochemical reference ranges for iguanas housed in a warm indoor and outdoor environment with regular exposure to direct sunlight. Original study. 51 clinically normal iguanas (18 males, 25 females, and 8 juveniles) housed in 3 Florida locations. Blood was collected from the coccygeal or ventral abdominal vein. Any samples that had obvious hemolysis or clot formation were not used. Leukocyte counts were determined manually; other hematologic values were obtained by use of a commercially available cell counter. Plasma biochemical values were determined by use of a spectrophotometric chemistry analyzer. Blood smears were stained with Wright-Giemsa and cytochemical stains for morphologic and cytochemical evaluation. Hematologic ranges were generally higher in this study than previously reported. Thrombocytes were variable in appearance between individuals and sometimes difficult to distinguish from lymphocytes on a Wright-Giemsa preparation. Concentrations of calcium, phosphorus, total protein, globulins, and cholesterol were significantly higher, and the albumin:globulin ratio was significantly lower, in healthy gravid females than in male or nongravid female iguanas. Nongravid females had significantly higher calcium and cholesterol concentrations, compared with males. The calcium:phosphorus ratio was > 1 in all iguanas. Gravid females had a calcium phosphorus product ranging between 210 and 800. Intracytoplasmic inclusions were identified within the erythrocytes of some iguanas. Hematologic ranges for iguanas in this study are higher than those reported for iguanas. Sex and age of the iguana should be considered when evaluating biochemical values. Healthy ovulating and gravid females may have significantly increased electrolyte and protein concentrations, but maintain a calcium:phosphorus ratio > 1.

  19. Low blood lead levels impair intellectual and hematological function in children from Cartagena, Caribbean coast of Colombia.

    Science.gov (United States)

    Alvarez-Ortega, Neda; Caballero-Gallardo, Karina; Olivero-Verbel, Jesus

    2017-12-01

    Lead produces numerous biochemical and physiological changes in humans, including hematological disorders, toxic effects on the central nervous system and in the function of several organs. The aim of this study was to determine blood lead levels (BLL) in children from Cartagena, Colombia, associating those with hematological and liver damage markers, the intelligence quotient (IQ), as well as with gene expression of the aminolevulinate dehydratase (ALAD), superoxide dismutase 1 (SOD1), gamma interferon (INF-γ), tumor necrosis factor (TNF) and tumor protein (p53). To achieve this purpose, 118 blood samples were collected from children 5-16 years old, with their respective informed consent from their parents. BLL was measured by atomic absorption; hematological parameters were obtained with automated systems; plasma was utilized to analyze hepatic toxicity markers, alanine aminotransferase (ALT), gamma-glutamyltransferase (γ-GT) and alkaline phosphatase (ALP); the Kaufman Brief Intelligence Test (K-BIT) was administered to measure the IQ; and gene expression was quantified from blood RNA. The mean BLL was 1.7±0.3μg/dL. A low proportion of the children (3.4%) had BLL above the CDC recommended limit (5μg/dL). BLL were correlated weakly, but negatively with child age, weight, height, body mass index, platelets wide distribution, mean platelet volume, γ-GT and IQ. There were not significant changes in the expression of evaluated genes. These results support the hypothesis that BLL below 5μg/dL may still be a detrimental factor on children's cognitive abilities, development and hematology, in line with recent concerns that there is no safe level of pediatric lead exposure. Copyright © 2017 Elsevier GmbH. All rights reserved.

  20. Effect of Resveratrol on Hematological and Biochemical Alterations in Rats Exposed to Fluoride

    Directory of Open Access Journals (Sweden)

    Nurgül Atmaca

    2014-01-01

    Full Text Available We investigated the protective effects of resveratrol on hematological and biochemical changes induced by fluoride in rats. A total of 28 rats were divided into 4 groups: control, resveratrol, fluoride, and fluoride/resveratrol (n=7 each, for a total of 21 days of treatment. Blood samples were taken and hematological and biochemical parameters were measured. Compared to the control group, the fluoride-treated group showed significant differences in several hematological parameters, including decreases in WBC, RBC, and PLT counts and neutrophil ratio. The group that received resveratrol alone showed a decrease in WBC count compared to the control group. Furthermore, in comparison to the control group, the fluoride group showed significantly increased ALT enzyme activity and decreased inorganic phosphorus level. The hematological and biochemical parameters in the fluoride + resveratrol treated group were similar to control group. In the fluoride + resveratrol group, resveratrol restored the changes observed following fluoride treatment, including decreased counts of WBC, RBC, and PLT, decreased neutrophil ratio and inorganic phosphorus levels, and elevated ALT enzyme activity. The present study showed that fluoride caused adverse effects in rats and that resveratrol reduced hematological and biochemical alterations produced by fluoride exposure.

  1. Bacterial Infections Following Splenectomy for Malignant and Nonmalignant Hematologic Diseases

    Science.gov (United States)

    Leone, Giuseppe; Pizzigallo, Eligio

    2015-01-01

    Splenectomy, while often necessary in otherwise healthy patients after major trauma, finds its primary indication for patients with underlying malignant or nonmalignant hematologic diseases. Indications of splenectomy for hematologic diseases have been reducing in the last few years, due to improved diagnostic and therapeutic tools. In high-income countries, there is a clear decrease over calendar time in the incidence of all indication splenectomy except nonmalignant hematologic diseases. However, splenectomy, even if with different modalities including laparoscopic splenectomy and partial splenectomy, continue to be a current surgical practice both in nonmalignant hematologic diseases, such as Immune Thrombocytopenic Purpura (ITP), Autoimmune Hemolytic Anemia (AIHA), Congenital Hemolytic Anemia such as Spherocytosis, Sickle Cell Anemia and Thalassemia and Malignant Hematological Disease, such as lymphoma. Today millions of people in the world are splenectomized. Splenectomy, independently of its cause, induces an early and late increase in the incidence of venous thromboembolism and infections. Infections remain the most dangerous complication of splenectomy. After splenectomy, the levels of antibody are preserved but there is a loss of memory B cells against pneumococcus and tetanus, and the loss of marginal zone monocytes deputed to immunological defense from capsulated bacteria. Commonly, the infections strictly correlated to the absence of the spleen or a decreased or absent splenic function are due to encapsulated bacteria that are the most virulent pathogens in this set of patients. Vaccination with polysaccharide and conjugate vaccines again Streptococcus pneumoniae, Haemophilus influenzae, and Neisseria meningitidis should be performed before the splenectomy. This practice reduces but does not eliminate the occurrence of overwhelming infections due to capsulated bacteria. At present, most of infections found in splenectomized patients are due to Gram

  2. High energy iron ion implantation into sapphire

    International Nuclear Information System (INIS)

    Allen, W.R.; Pedraza, D.F.

    1990-01-01

    Sapphire specimens of c-axis orientation were implanted at room temperature with iron ions at energies of 1.2 and of 2 MeV to various fluences up to 8 x 10 16 cm -2 . The damage induced by the implantations was assessed by Rutherford backscattering spectroscopy in random and channeling geometries. Dechanneling in both sublattices was observed to saturate for all implantation conditions. Disorder in the aluminum sublattice was found to increase with depth at a significantly slower rate than in the oxygen sublattice. In the oxygen sublattice, a relative yield, χ, of 0.80 ± 0.11 was attained at a depth of 0.1 μm and remained constant up to the measured depth of 0.45 μm. In the aluminum sublattice, the disorder increased with depth and the dechanneling asymptotically approached χ =0.70 ± 0.04 at 0.45 μm. These results are discussed and compared with those for shallower Fe implantations obtained by other researchers

  3. Using a novel spectroscopic reflectometer to optimize a radiation-hardened submicron silicon-on-sapphire CMOS process

    International Nuclear Information System (INIS)

    Do, N.T.; Zawaideh, E.; Vu, T.Q.; Warren, G.; Mead, D.; Do, N.T.; Li, G.P.; Tsai, C.S.

    1999-01-01

    A radiation-hardened sub-micron silicon-on-sapphire CMOS process is monitored and optimized using a novel optical technique based on spectroscopic reflectometry. Quantitative measurements of the crystal quality, surface roughness, and device radiation hardness show excellent correlation between this technique and the Atomic Force Microscopy. (authors)

  4. 78 FR 56691 - Sapphire Power Marketing LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2013-09-13

    ... Power Marketing LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for... Sapphire Power Marketing LLC's application for market-based rate authority, with an accompanying rate... submission of protests and interventions in lieu of paper, using the FERC Online links at http://www.ferc.gov...

  5. Blood gases, biochemistry, and hematology of Galapagos green turtles (Chelonia mydas.

    Directory of Open Access Journals (Sweden)

    Gregory A Lewbart

    Full Text Available The green turtle, Chelonia mydas, is an endangered marine chelonian with a circum-global distribution. Reference blood parameter intervals have been published for some chelonian species, but baseline hematology, biochemical, and blood gas values are lacking from the Galapagos sea turtles. Analyses were done on blood samples drawn from 28 green turtles captured in two foraging locations on San Cristóbal Island (14 from each site. Of these turtles, 20 were immature and of unknown sex; the other eight were males (five mature, three immature. A portable blood analyzer (iSTAT was used to obtain near immediate field results for pH, lactate, pO2, pCO2, HCO3-, Hct, Hb, Na, K, iCa, and Glu. Parameter values affected by temperature were corrected in two ways: (1 with standard formulas; and (2 with auto-corrections made by the iSTAT. The two methods yielded clinically equivalent results. Standard laboratory hematology techniques were employed for the red and white blood cell counts and the hematocrit determination, which was also compared to the hematocrit values generated by the iSTAT. Of all blood analytes, only lactate concentrations were positively correlated with body size. All other values showed no significant difference between the two sample locations nor were they correlated with body size or internal temperature. For hematocrit count, the iSTAT blood analyzer yielded results indistinguishable from those obtained with high-speed centrifugation. The values reported in this study provide baseline data that may be useful in comparisons among populations and in detecting changes in health status among Galapagos sea turtles. The findings might also be helpful in future efforts to demonstrate associations between specific biochemical parameters and disease.

  6. Temporal changes in hematologic markers after splenectomy, splenic embolization, and observation for trauma.

    Science.gov (United States)

    Wernick, B; Cipriano, A; Odom, S R; MacBean, U; Mubang, R N; Wojda, T R; Liu, S; Serres, S; Evans, D C; Thomas, P G; Cook, C H; Stawicki, S P

    2017-06-01

    The spleen is one of the most commonly injured abdominal solid organs during blunt trauma. Modern management of splenic trauma has evolved to include non-operative therapies, including observation and angioembolization to preclude splenectomy in most cases of blunt splenic injury. Despite the shift in management strategies, relatively little is known about the hematologic changes associated with these various modalities. The aim of this study was to determine if there are significant differences in hematologic characteristics over time based on the treatment modality employed following splenic trauma. We hypothesized that alterations seen in hematologic parameters would vary between observation (OBS), embolization (EMB), and splenectomy (SPL) in the setting of splenic injury. An institutional review board-approved, retrospective study of routine hematologic indices examined data between March 2000 and December 2014 at three academic trauma centers. A convenience sample of patients with splenic trauma and admission lengths of stay >96 h was selected for inclusion, resulting in a representative sample of each sub-group (OBS, EMB, and SPL). Basic demographics and injury severity data (ISS) were abstracted. Platelet count, red blood cell (RBC) count and RBC indices, and white blood cell (WBC) count with differential were analyzed between the time of admission and a maximum of 1080 h (45 days) post-injury. Comparisons between OBS, EMB, and SPL groups were then performed using non-parametric statistical testing, with statistical significance set at p splenic injury grade varied by interventional modality (grade 4 for SPL, 3 for EMB, and 2 for OBS, p splenic injuries managed with SPL, EMB, or OBS. As expected, observed WBC counts were highest following SPL, then EMB, and finally OBS. No differences were noted in RBC count between the three groups, but RDW was significantly greater following SPL compared to EMB and OBS. We also found that MCV was highest following OBS

  7. Air-void embedded GaN-based light-emitting diodes grown on laser drilling patterned sapphire substrates

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hao; Li, Yufeng; Wang, Shuai; Feng, Lungang; Xiong, Han; Yun, Feng, E-mail: fyun2010@mail.xjtu.edu.cn [Key Laboratory of Physical Electronics and Devices of Ministry of Education and Shaanxi Provincial Key Laboratory of Photonics and Information Technology, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China); Solid-State Lighting Engineering Research Center, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China); Su, Xilin [Shaanxi Supernova Lighting Technology Co., Ltd., Xi’an, Shaanxi 710075 (China)

    2016-07-15

    Air-void structure was introduced in GaN-based blue light-emitting diodes (LED) with one-step growth on periodic laser drilling patterned sapphire substrate, which free of any photolithography or wet/dry etching process. The influence of filling factors (FF) of air-void on crystal quality and optical performance were investigate. Transmission electron microscopy images and micro-Raman spectroscopy indicated that the dislocation was bended and the partially compressed strain was released. When FF was 55.43%, compared with the LED structure grown on flat sapphire substrate, the incorporation of air-void was observed to reduce the compressed stress of ∼20% and the luminance intensity has improved by 128%. Together with the simulated reflection intensity enhancement by finite difference time-domain (FDTD) method, we attribute the enhanced optical performance to the combined contribution of strong back-side light reflection of air-void and better GaN epitaxial quality. This approach provides a simple replacement to the conventional air-void embedded LED process.

  8. 5-nJ Femtosecond Ti3+:sapphire laser pumped with a single 1 W green diode

    Science.gov (United States)

    Muti, Abdullah; Kocabas, Askin; Sennaroglu, Alphan

    2018-05-01

    We report a Kerr-lens mode-locked, extended-cavity femtosecond Ti3+:sapphire laser directly pumped at 520 nm with a 1 W AlInGaN green diode. To obtain energy scaling, the short x-cavity was extended with a q-preserving multi-pass cavity to reduce the pulse repetition rate to 5.78 MHz. With 880 mW of incident pump power, we obtained as high as 90 mW of continuous-wave output power from the short cavity by using a 3% output coupler. In the Kerr-lens mode-locked regime, the extended cavity produced nearly transform-limited 95 fs pulses at 776 nm. The resulting energy and peak power of the pulses were 5.1 nJ and 53 kW, respectively. To our knowledge, this represents the highest pulse energy directly obtained to date from a mode-locked, single-diode-pumped Ti3+:sapphire laser.

  9. Fibrinogen measurements in plasma and whole blood: a performance evaluation study of the dry-hematology system.

    Science.gov (United States)

    Ogawa, Satoru; Tanaka, Kenichi A; Nakajima, Yasufumi; Nakayama, Yoshinobu; Takeshita, Jun; Arai, Masatoshi; Mizobe, Toshiki

    2015-01-01

    An accurate and rapid determination of fibrinogen level is important during hemorrhage to establish a timely hemostatic intervention. The accuracy of fibrinogen measurements may be affected by the specific methodology for its determination, fluid therapies, and anticoagulant agents. The dry-hematology method (DRIHEMATO®) is a novel approach to determine fibrinogen levels in plasma and whole blood based on thrombin-activated coagulation time. We hypothesized that plasma or whole blood fibrinogen level using the dry-hematology method would be similar to those measured with conventional plasma fibrinogen assays. Acquired hypofibrinogenemia was modeled by serial dilutions of blood samples obtained from 12 healthy volunteers. Citrated whole blood samples were diluted with either normal saline, 5% human albumin, or 6% hydroxyethyl starch to achieve 25%, 50%, and 75% volume replacement. The dry-hematology method, the Clauss method, the prothrombin time (PT)-derived method, determination of antigen levels, and thromboelastometric fibrin formation were compared in plasma or whole blood samples. The effect of heparin on each assay was examined (0 to 6 IU/mL). Comparisons of dry-hematology and other methods were also conducted using ex vivo samples obtained from cardiac surgical patients (n = 60). In plasma samples, there were no significant differences between dry-hematology and the Clauss method, while dry-hematology showed lower fibrinogen levels compared with PT-derived and antigen level methods. The dry-hematology method yielded acceptable concordance correlation coefficients (Pc) with the Clauss method, the PT-derived method, and fibrinogen antigen levels (Pc = 0.91-0.99). The type of diluents and heparin affected the results of the PT-derived method and thromboelastometric assay, but not the dry-hematology method. In cardiac surgical patients, the overall correlation in fibrinogen levels between dry-hematology and the other methods was comparable to the results from

  10. Baseline hematology and serum biochemistry results for Indian leopards (Panthera pardus fusca

    Directory of Open Access Journals (Sweden)

    Arun Attur Shanmugam

    2017-07-01

    Full Text Available Aim: The aim of the study was to establish the baseline hematology and serum biochemistry values for Indian leopards (Panthera pardus fusca, and to assess the possible variations in these parameters based on age and gender. Materials and Methods: Hemato-biochemical test reports from a total of 83 healthy leopards, carried out as part of routine health evaluation in Bannerghatta Biological Park and Manikdoh Leopard Rescue Center, were used to establish baseline hematology and serum biochemistry parameters for the subspecies. The hematological parameters considered for the analysis included hemoglobin (Hb, packed cell volume, total erythrocyte count (TEC, total leukocyte count (TLC, mean corpuscular volume (MCV, mean corpuscular Hb (MCH, and MCH concentration. The serum biochemistry parameters considered included total protein (TP, albumin, globulin, aspartate aminotransferase, alanine aminotransferase (ALT, blood urea nitrogen, creatinine, triglycerides, calcium, and phosphorus. Results: Even though few differences were observed in hematologic and biochemistry values between male and female Indian leopards, the differences were statistically not significant. Effects of age, however, were evident in relation to many hematologic and biochemical parameters. Sub-adults had significantly greater values for Hb, TEC, and TLC compared to adults and geriatric group, whereas they had significantly lower MCV and MCH compared to adults and geriatric group. Among, serum biochemistry parameters the sub-adult age group was observed to have significantly lower values for TP and ALT than adult and geriatric leopards. Conclusion: The study provides a comprehensive analysis of hematologic and biochemical parameters for Indian leopards. Baselines established here will permit better captive management of the subspecies, serve as a guide to assess the health and physiological status of the free ranging leopards, and may contribute valuable information for making

  11. Baseline hematology and serum biochemistry results for Indian leopards (Panthera pardus fusca)

    Science.gov (United States)

    Shanmugam, Arun Attur; Muliya, Sanath Krishna; Deshmukh, Ajay; Suresh, Sujay; Nath, Anukul; Kalaignan, Pa; Venkataravanappa, Manjunath; Jose, Lyju

    2017-01-01

    Aim: The aim of the study was to establish the baseline hematology and serum biochemistry values for Indian leopards (Panthera pardus fusca), and to assess the possible variations in these parameters based on age and gender. Materials and Methods: Hemato-biochemical test reports from a total of 83 healthy leopards, carried out as part of routine health evaluation in Bannerghatta Biological Park and Manikdoh Leopard Rescue Center, were used to establish baseline hematology and serum biochemistry parameters for the subspecies. The hematological parameters considered for the analysis included hemoglobin (Hb), packed cell volume, total erythrocyte count (TEC), total leukocyte count (TLC), mean corpuscular volume (MCV), mean corpuscular Hb (MCH), and MCH concentration. The serum biochemistry parameters considered included total protein (TP), albumin, globulin, aspartate aminotransferase, alanine aminotransferase (ALT), blood urea nitrogen, creatinine, triglycerides, calcium, and phosphorus. Results: Even though few differences were observed in hematologic and biochemistry values between male and female Indian leopards, the differences were statistically not significant. Effects of age, however, were evident in relation to many hematologic and biochemical parameters. Sub-adults had significantly greater values for Hb, TEC, and TLC compared to adults and geriatric group, whereas they had significantly lower MCV and MCH compared to adults and geriatric group. Among, serum biochemistry parameters the sub-adult age group was observed to have significantly lower values for TP and ALT than adult and geriatric leopards. Conclusion: The study provides a comprehensive analysis of hematologic and biochemical parameters for Indian leopards. Baselines established here will permit better captive management of the subspecies, serve as a guide to assess the health and physiological status of the free ranging leopards, and may contribute valuable information for making effective

  12. Tuning the sapphire EFG process to the growth of Al2O3/YAG/ZrO2:Y eutectic

    Science.gov (United States)

    Carroz, L.; Duffar, T.

    2018-05-01

    In this work, a model is proposed, in order to analytically study the working point of the Edge defined Film-fed Growth (EFG) pulling of crystal plates. The model takes into account the heat equilibrium at the interface and the pressure equilibrium across the meniscus. It is validated on an industrial device dedicated to the pulling of sapphire ribbons. Then, the model is applied to pulling ceramic alloy plates, of the ternary eutectic Al2O3/YAG/ZrO2:Y. This allowed understanding the experimental difficulties of pulling this new material and suggested improvements of the control software. From these results, pulling net shaped ceramic alloy plates was successful in the same industrial equipment as used for sapphire.

  13. Use of Electronic Consultation System to Improve Access to Care in Pediatric Hematology/Oncology.

    Science.gov (United States)

    Johnston, Donna L; Murto, Kimmo; Kurzawa, Julia; Liddy, Clare; Keely, Erin; Lai, Lillian

    2017-10-01

    Electronic consultations (eConsult) allow for communication between primary care providers and specialists in an asynchronous manner. This study examined provider satisfaction, topics of interest, and efficiency of eConsult in pediatric hematology/oncology in Ottawa, Canada. We conducted a cross-sectional assessment of all eConsult cases directed to pediatric hematology/oncology specialists using the Champlain BASE (Building Access to Specialists through eConsultation) eConsult service from June 1, 2014 to May 31, 2016. There were 1064 eConsults to pediatrics during the study timeperiod and pediatric hematology/oncology consults accounted for 8% (85). During the same study timeperiod, 524 consults were seen in the pediatric hematology/oncology clinic. The majority of the eConsults were for hematology (90.5%) in contrast to oncology topics (9.5%). The most common topics were anemia, hemoglobinopathy, bleeding disorder, and thrombotic state. Primary care providers rated the eConsult service very highly, and their comments were very positive. The eConsult service resulted in deferral of 40% of consults originally contemplated to require a face-to-face specialist visit. This study showed successful implementation and use of the eConsult service for pediatric hematology/oncology and resulted in avoidance of a large number of face-to-face consultation. The common topics identified areas for continuing medical education.

  14. Properties of grazing-incidence pulsed Ti:sapphire laser oscillator

    International Nuclear Information System (INIS)

    Tamura, Koji

    2008-03-01

    A pulsed operation of a grazing-incidence double-grating Ti:sapphire laser oscillator that consists of a gain medium, back mirror, and a pair of gratings, was studied. A stable single-longitudinal-mode operation was achievable. From the calculation of the optical path trajectories, it can be explained by the increased beam walk-off from the gain medium by the introduction of the second grating compared with the conventional single-grating grazing-incidence cavity geometry. The improved spectral property was also explained by the calculations of increased dispersion. The results indicate that the oscillator configuration was useful for the applications which require stable mode operation and narrow linewidth such as the high resolution spectroscopy or the laser isotope separation. (author)

  15. Laser ablation of dental calculus at 400 nm using a Ti:sapphire laser

    Science.gov (United States)

    Schoenly, Joshua E.; Seka, Wolf; Rechmann, Peter

    2009-02-01

    A Nd:YAG laser-pumped, frequency-doubled Ti:sapphire laser is used for selective ablation of calculus. The laser provides calculus removal. This is in stark contrast with tightly focused Gaussian beams that are energetically inefficient and lead to irreproducible results. Calculus is well ablated at high fluences >=2J/cm2 stalling occurs below this fluence because of photobleaching. Healthy hard tissue is not removed at fluences <=3 J/cm2.

  16. Optical transmittance investigation of 1-keV ion-irradiated sapphire crystals as potential VUV to NIR window materials of fusion reactors

    Directory of Open Access Journals (Sweden)

    Keisuke Iwano

    2016-10-01

    Full Text Available We investigate the optical transmittances of ion-irradiated sapphire crystals as potential vacuum ultraviolet (VUV to near-infrared (NIR window materials of fusion reactors. Under potential conditions in fusion reactors, sapphire crystals are irradiated with hydrogen (H, deuterium (D, and helium (He ions with 1-keV energy and ∼ 1020-m-2 s-1 flux. Ion irradiation decreases the transmittances from 140 to 260 nm but hardly affects the transmittances from 300 to 1500 nm. H-ion and D-ion irradiation causes optical absorptions near 210 and 260 nm associated with an F-center and an F+-center, respectively. These F-type centers are classified as Schottky defects that can be removed through annealing above 1000 K. In contrast, He-ion irradiation does not cause optical absorptions above 200 nm because He-ions cannot be incorporated in the crystal lattice due to the large ionic radius of He-ions. Moreover, the significant decrease in transmittance of the ion-irradiated sapphire crystals from 140 to 180 nm is related to the light scattering on the crystal surface. Similar to diamond polishing, ion irradiation modifies the crystal surface thereby affecting the optical properties especially at shorter wavelengths. Although the transmittances in the VUV wavelengths decrease after ion irradiation, the transmittances can be improved through annealing above 1000 K. With an optical transmittance in the VUV region that can recover through simple annealing and with a high transparency from the ultraviolet (UV to the NIR region, sapphire crystals can therefore be used as good optical windows inside modern fusion power reactors in terms of light particle loadings of hydrogen isotopes and helium.

  17. Reference values of clinical chemistry and hematology parameters in rhesus monkeys (Macaca mulatta).

    Science.gov (United States)

    Chen, Younan; Qin, Shengfang; Ding, Yang; Wei, Lingling; Zhang, Jie; Li, Hongxia; Bu, Hong; Lu, Yanrong; Cheng, Jingqiu

    2009-01-01

    Rhesus monkey models are valuable to the studies of human biology. Reference values for clinical chemistry and hematology parameters of rhesus monkeys are required for proper data interpretation. Whole blood was collected from 36 healthy Chinese rhesus monkeys (Macaca mulatta) of either sex, 3 to 5 yr old. Routine chemistry and hematology parameters, and some special coagulation parameters including thromboelastograph and activities of coagulation factors were tested. We presented here the baseline values of clinical chemistry and hematology parameters in normal Chinese rhesus monkeys. These data may provide valuable information for veterinarians and investigators using rhesus monkeys in experimental studies.

  18. Blood at 70: its roots in the history of hematology and its birth.

    Science.gov (United States)

    Coller, Barry S

    2015-12-10

    This year we celebrate Blood's 70th year of publication. Created from the partnership of the book publisher Henry M. Stratton and the prominent hematologist Dr William Dameshek of Tufts School of Medicine, Blood has published many papers describing major advances in the science and clinical practice of hematology. Blood's founding antedated that of the American Society of Hematology (ASH) by more than 11 years and Stratton and Dameshek helped galvanize support for the creation of ASH. In this review, I place the birth of Blood in the context of the history of hematology before 1946, emphasizing the American experience from which it emerged, and focusing on research conducted during World War II. I also provide a few milestones along Blood's 70 years of publication, including: the growth in Blood's publications, the evolution of its appearance, the countries of submission of Blood papers, current subscriptions to Blood, and the evolution of topics reported in Blood's papers. The latter provides a snapshot of the evolution of hematology as a scientific and clinical discipline and the introduction of new technology to study blood and bone marrow. Detailed descriptions of the landmark discoveries reported in Blood will appear in later papers celebrating Blood's birthday authored by past Editors-in-Chief. © 2015 by The American Society of Hematology.

  19. Hematological Manifestation in HIV Infected Children

    International Nuclear Information System (INIS)

    Bhowmik, A.; Banerjee, P.

    2015-01-01

    Objective: To determine the common hematological abnormalities in HIV infected children and any association of these abnormalities with HIV disease severity. Study Design: Cross-sectional study. Place and Duration of Study: Regional Pediatric ART centre, Medical College and Hospital, Kolkata, West Bengal, India, from November 2011 to November 2012. Methodology: Children up to 12 years with confirmed diagnosis of HIV infection were clinically examined and tested for complete hemogram and CD4 count. Bone marrow study was done in selected patient depending on hemogram report. Children were divided in different stages according to WHO clinical staging. Each of the hematological parameters was assessed for any association with progression of disease. Fisher's Exact Test was used for determining the association between WHO clinical staging and abnormal blood parameters. P-value < 0.05 was taken as significant. Results: Sixty nine percent of the study population was anemic; 47.37% (18/38), 66.67% (8/12), 71.43% (15/21) and 93.10% (27/29) of stage 1, 2, 3 and 4 respectively were anemic in the study population (p=0.001). Leucopenia was present in 34% (34/100) children. Neutropenia and lymphopenia was present in 19% (19/100) and 22% (22/100) children. Lymphopenia was present in 7.89% (3/38), 16.67% (2/12), 19.05% (4/21) and 44.83% (13/29) of patient with stage 1, 2, 3 and 4 respectively (p=0.020). Eosinophilia was present in 17% (17/100) and thrombocytopenia in 11% (11/100) children. 2 patients with stage 4 disease were with hypoplastic bone marrow. Conclusion: Anemia was the most common hematological abnormality in HIV infected children. Anemia and lymphopenia had a significant association with the stage of the disease. (author)

  20. Nanotechnology applications in hematological malignancies (Review)

    Science.gov (United States)

    SAMIR, AHMED; ELGAMAL, BASMA M; GABR, HALA; SABAAWY, HATEM E

    2015-01-01

    A major limitation to current cancer therapies is the development of therapy-related side-effects and dose limiting complications. Moreover, a better understanding of the biology of cancer cells and the mechanisms of resistance to therapy is rapidly developing. The translation of advanced knowledge and discoveries achieved at the molecular level must be supported by advanced diagnostic, therapeutic and delivery technologies to translate these discoveries into useful tools that are essential in achieving progress in the war against cancer. Nanotechnology can play an essential role in this aspect providing a transforming technology that can translate the basic and clinical findings into novel diagnostic, therapeutic and preventive tools useful in different types of cancer. Hematological malignancies represent a specific class of cancer, which attracts special attention in the applications of nanotechnology for cancer diagnosis and treatment. The aim of the present review is to elucidate the emerging applications of nanotechnology in cancer management and describe the potentials of nanotechnology in changing the key fundamental aspects of hematological malignancy diagnosis, treatment and follow-up. PMID:26134389

  1. Hematological outcome in neonatal alloimmune hemolytic disease

    NARCIS (Netherlands)

    Rath, Mirjam Eva Aafke

    2013-01-01

    This thesis focuses on several aspects related to the hematological outcome of infants with hemolytic disease of the fetus and newborn (HDFN) due to red blood cell alloimmunization, including pathogenesis and management of the disease. The presence of leukocytopenie and thrombocytopenia support the

  2. [North-South cooperation on transfusion and hematology teaching: A Benin experience].

    Science.gov (United States)

    Lafia, E; Anani, L; Glitho, S; Bankole, C; Fachinan, H; Py, J-Y; Domenech, J; Martenot, B; Colombat, P; Chobli, M; Zohoun, I

    2015-06-01

    Hematologic diseases are a significant part of health disorders in Benin. As an example, anemia is the second cause of hospitalization, measuring up to 7.9% all over the country (National Plan of Sanitary Development, 2009-2018). By contrast, there is only one active hematologist in the country. Thanks to two partnerships, on one hand between the health sciences faculty in Cotonou (Benin) and the medicine one in Tours (France), and on the other hand between the Beninese Blood Transfusion National Agency and the French Blood Establishment, a first blood transfusion and hematology formation was held in Cotonou on December 2014. Among other benefits, was created an hematology-transfusion network in order to facilitate relations between Beninese hospital doctors, with the support of the two French partner institutions. The article describes this progress. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  3. Airborne particulate concentration during laser hair removal: A comparison between cold sapphire with aqueous gel and cryogen skin cooling.

    Science.gov (United States)

    Ross, Edward V; Chuang, Gary S; Ortiz, Arisa E; Davenport, Scott A

    2018-04-01

    High concentrations of sub-micron nanoparticles have been shown to be released during laser hair removal (LHR) procedures. These emissions pose a potential biohazard to healthcare workers that have prolonged exposure to LHR plume. We sought to demonstrate that cold sapphire skin cooling done in contact mode might suppress plume dispersion during LHR. A total of 11 patients were recruited for laser hair removal. They were treated on the legs and axilla with a 755 or 1064 nm millisecond-domain laser equipped with either (i) cryogen spray (CSC); (ii) refrigerated air (RA); or (iii) contact cooling with sapphire (CC). Concentration of ultrafine nanoparticles <1 μm were measured just before and during LHR with the three respective cooling methods. For contact cooling (CC), counts remained at baseline levels, below 3,500 parts per cubic centimeter (ppc) for all treatments. In contrast, the CSC system produced large levels of plume, peaking at times to over 400,000 ppc. The CA cooled system produced intermediate levels of plume, about 35,000 ppc (or about 10× baseline). Cold Sapphire Skin cooling with gel suppresses plume during laser hair removal, potentially eliminating the need for smoke evacuators, custom ventilation systems, and respirators during LHR. Lasers Surg. Med. 50:280-283, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  4. Hematological complications in children subjected to extracorporeal membrane oxygenation.

    Science.gov (United States)

    Santiago, M J; Gómez, C; Magaña, I; Muñoz, V; Saiz, P; Sánchez, A; López-Herce, J

    2018-03-29

    To analyze the hematological complications and need for transfusions in children receiving extracorporeal life support (ECLS). A retrospective study was carried out. A pediatric intensive care unit. Children under 18 years of age treated with ECLS between September 2006 and November 2015. None. Patient and ECLS characteristics, anticoagulation, hematological and coagulation parameters, transfusions and clinical course. A total of 100 patients (94 with heart disease) with a median age of 11 months were studied. Seventy-six patients presented bleeding. The most frequent bleeding point being the mediastinum and 39 patients required revision surgery. In the first 3days, 97% of the patients required blood transfusion (34.4ml/kg per day), 94% platelets (21.1ml/kg per day) and 90% plasma (26.6ml/kg per day). Patients who were in the postoperative period, those who were bleeding at the start of ECLS, those requiring revision surgery, those who could not suspend extracorporeal circulation, and those subjected to transthoracic cannulation required a greater volume of transfusions than the rest of the patients. Thromboembolism occurred in 14 patients and hemolysis in 33 patients. Mortality among the children who were bleeding at the start of ECLS (57.6%) was significantly higher than in the rest of the patients (37.5%) (P=0.048). Children treated with ECLS present high blood product needs. The main factors related to transfusions were postoperative period, bleeding at the start of ECLS, revision surgery, transthoracic cannulation, and the impossibility of suspending extracorporeal circulation. Children with bleeding suffered greater mortality than the rest of the patients. Copyright © 2018 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  5. Hematologic syndrome in man modeled from mammalian lethality

    International Nuclear Information System (INIS)

    Jones, T.D.

    1981-01-01

    Data on acute radiation lethality due to failure of the hematologic system in rats, mice, dogs, swine, monkeys and man are analyzed. Based on the available data, the mortality incidences for 1-100% levels can be computed directly if one has only an estimate of the dose lethal to 50% of the population (LD 50 ) for the mammalian strain and radiation environment of interest. The sole restriction is that the dose profile to the marrow be moderately uniform. If an LD 50 for any exposure situation has been measured, then one can readily scale to any desired situation through implicit-biological and empirical-physical relationships. The LD 50 for man, exposed to an isotropic cloud of photons, and knowledge of the bone-marrow dose profiles readily permit evaluation of the model for other levels of human mortality from different irradiating particles, partial body irradiation and spatially dependent and/or mixed radiation environments. (author)

  6. Neutropenia in pediatric hematology/oncology practice

    Directory of Open Access Journals (Sweden)

    E. A. Deordieva

    2015-06-01

    Full Text Available Acquired neutropenia is one of the most common conditions in pediatric hematology practice. These conditions usually are benign. In contrast, congenital neutropenia are rare conditions, but in the absence of pathogenic therapy can cause fatal complications. Approach to the differential diagnosis and management of these patients are discussed in this review.

  7. A higher-order-mode fiber delivery for Ti:Sapphire femtosecond lasers

    DEFF Research Database (Denmark)

    Jespersen, Kim Giessmann; Le, Tuan; Grüner-Nielsen, Lars Erik

    2010-01-01

    We report the first higher-order-mode fiber with anomalous dispersion at 800nm and demonstrate its potential in femtosecond pulse delivery for Ti:Sapphire femtosecond lasers. We obtain 125fs pulses after propagating a distance of 3.6 meters in solid-silica fiber. The pulses could be further...... compressed in a quartz rod to nearly chirp-free 110fs pulses. Femtosecond pulse delivery is achieved by launching the laser output directly into the delivery fiber without any pre-chirping of the input pulse. The demonstrated pulse delivery scheme suggests scaling to >20meters for pulse delivery in harsh...

  8. Hematologic patients' clinical and psychosocial experiences with implanted long-term central venous catheter

    DEFF Research Database (Denmark)

    Møller, Tom; Adamsen, Lis

    2010-01-01

    A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients.......A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients....

  9. Quantifying Heterogeneities in Soil Cover and Weathering in the Bitterroot and Sapphire Mountains, Montana: Implications for Glacial Legacies and their Morphologic Control on Soil Formation

    Science.gov (United States)

    Benjaram, S. S.; Dixon, J. L.

    2017-12-01

    To what extent is chemical weathering governed by a landscape's topography? Quantifying chemical weathering in both steep rocky landscapes and soil-mantled landscapes requires describing heterogeneity in soil and rock cover at local and landscape scales. Two neighboring mountain ranges in the northern Rockies of western Montana, USA, provide an ideal natural laboratory in which to investigate the relationship between soil chemical weathering, persistence of soil cover, and topography. We focus our work in the previously glaciated Bitterroot Mountains, which consist of steep, rock-dominated hillslopes, and the neighboring unglaciated Sapphire Mountains, which display convex, soil-mantled hillslopes. Soil thickness measurements, soil and rock geochemistry, and digital terrain analysis reveal that soils in the rock-dominated Bitterroot Mountains are only slightly less weathered than those in the Sapphire Mountains. However, these differences are magnified when adjusted for rock fragments at a local scale and bedrock cover at a landscape scale, using our newly developed metric, the rock-adjusted chemical depletion fraction (RACDF) and rock-adjusted mass transfer coefficient (RA τ). The Bitterroots overall are 30% less weathered than the Sapphires despite higher mean annual precipitation in the former, with an average rock-adjusted CDF of 0.38 in the postglacial Bitterroots catchment and 0.61 in the nonglacial Sapphire catchment, suggesting that 38% of rock mass is lost in the conversion to soil in the Bitterroots, whereas 61% of rock mass is lost in the nonglaciated Sapphires. Because the previously glaciated Bitterroots are less weathered despite being wetter, we conclude that the glacial history of this landscape exerts more influence on soil chemical weathering than does modern climate. However, while previous studies have correlated weathering intensity with topographic parameters such as slope gradient, we find little topographic indication of specific controls

  10. Effect of age, sex and physiological stages on hematological indices of Banni buffalo (Bubalus bubalis).

    Science.gov (United States)

    Patel, Mehul D; Lateef, Abdul; Das, Hemen; Patel, Ajay S; Patel, Ajay G; Joshi, Axay B

    2016-01-01

    To determine the physiological baseline values for hematological indices of Banni buffalo (Bubalus bubalis) as well as to assess their alteration due to age, sex and physiological stages. A total of 42 clinically healthy Banni buffaloes were categorized into seven groups (n=6): Group I (male calves ≤1 year), Group II (bulls >1 year), Group III (female calves ≤1 year), Group IV (pregnant lactating buffaloes), Group V (non-pregnant lactating buffaloes), Group VI (pregnant dry buffaloes), and Group VII (non-pregnant dry buffaloes). Blood samples collected aseptically from all the experimental groups were analyzed employing automated hematology analyzer. The data obtained were statistically analyzed; the mean and standard deviations were calculated and set as the reference values. The erythrocytic indices viz. total erythrocytes count (TEC), hemoglobin, and packed cell volume (PCV) were significantly higher in bulls as compared to that of male calves unlike mean corpuscular volume, mean corpuscular hemoglobin (MCH), and MCH concentration. The female calves had higher TEC and PCV than the adult buffaloes irrespective of sex. The total leukocyte count (TLC) and neutrophil counts in male calves were significantly lower than the bulls unlike the eosinophil, while monocyte and basophil remained unchanged with age. The TLC, differential leukocyte count and platelet count varied non-significantly among the adult female groups at different physiological stages. However, neutrophils were found to be apparently higher in lactating buffaloes. The present study would be helpful for physiological characterization of this unique buffalo breed of Gujarat. Further, data generated may be a tool for monitoring the health and prognosis as well as diagnosis of diseases.

  11. Growth performance, carcass and hematological characteristics of ...

    African Journals Online (AJOL)

    Growth performance, carcass and hematological characteristics of rabbits fed graded levels of tiger nuts ( Cyperus esculentus ) ... (p>0.05) difference between treatments. Results demonstrated that (Cyperus esculentus) could be used up to 5% in rabbit's diets without adverse effect on the animals' performance and health.

  12. Survival From Childhood Hematological Malignancies in Denmark

    DEFF Research Database (Denmark)

    Erdmann, Friederike; Winther, Jeanette Falck; Dalton, Susanne Oksbjerg

    2016-01-01

    BACKGROUND: Due to diverse findings as to the role of family factors for childhood cancer survival even within Europe, we explored a nationwide, register-based cohort of Danish children with hematological malignancies. METHODS: All children born between 1973 and 2006 and diagnosed with a hematolo...

  13. 78 FR 54487 - Abbott Laboratories; Diagnostic-Hematology; Including On-Site Leased Workers From Manpower...

    Science.gov (United States)

    2013-09-04

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-82,379] Abbott Laboratories... February 22, 2013, applicable to workers of Abbott Laboratories, Diagnostic--Hematology division, including... Clara, California location of Abbott Laboratories, Diagnostic--Hematology Division. The Department has...

  14. Optical and structural behaviour of Mn implanted sapphire

    International Nuclear Information System (INIS)

    Marques, C.; Franco, N.; Kozanecki, A.; Silva, R.C. da; Alves, E.

    2006-01-01

    Sapphire single crystals were implanted at room temperature with 180 keV manganese ions to fluences up to 1.8 x 10 17 cm -2 . The samples were annealed at 1000 deg. C in oxidizing or reducing atmosphere. Surface damage was observed after implantation of low fluences, the amorphous phase being observed after implantation of 5 x 10 16 cm -2 , as seen by Rutherford backscattering spectroscopy under channelling conditions. Thermal treatments in air annealed most of the implantation related defects and promoted the redistribution of the manganese ions, in a mixed oxide phase. X-ray diffraction studies revealed the presence of MnAl 2 O 4 . On the contrary, similar heat treatments in vacuum led to enhanced out diffusion of Mn while the matrix remained highly damaged. The analysis of laser induced luminescence performed after implantation showed the presence of an intense red emission

  15. A microwave exciter for Cs frequency standards based on a sapphire-loaded cavity oscillator.

    Science.gov (United States)

    Koga, Y; McNeilage, C; Searls, J H; Ohshima, S

    2001-01-01

    A low noise and highly stable microwave exciter system has been built for Cs atomic frequency standards using a tunable sapphire-loaded cavity oscillator (SLCO), which works at room temperature. This paper discusses the successful implementation of a control system for locking the SLCO to a long-term reference signal and reports an upper limit of the achieved frequency tracking error 6 x 10(-15) at tau = 1 s.

  16. Nd{sup 3+}-doped colloidal SiO{sub 2} composite abrasives: Synthesis and the effects on chemical mechanical polishing (CMP) performances of sapphire wafers

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Tingting; Lei, Hong, E-mail: hong_lei2005@aliyun.com

    2017-08-15

    Highlights: • The novel Nd{sup 3+}-doped colloidal SiO{sub 2} abrasives were synthesized by seed-introduced method. • The Nd{sup 3+}-doped colloidal SiO{sub 2} abrasives exhibited lower Ra and higher MRR on sapphire during CMP. • The cores SiO{sub 2} were coated by the shells (SiO{sub 2}, Nd{sub 2}Si{sub 2}O{sub 7} and Nd(OH){sub 3}) via chemical bonds and hydrogen bonds. • XPS analysis revealed the solid-state chemical reaction between Nd{sup 3+}-doped colloidal SiO{sub 2} abrasives and sapphire during CMP. - Abstract: Abrasive is one of the most important factors in chemical mechanical polishing (CMP). In order to improve the polishing qualities of sapphire substrates, the novel Nd{sup 3+}-doped colloidal SiO{sub 2} composite abrasives were prepared by seed-induced growth method. In this work, there were a series of condensation reactions during the synthesis process of Nd{sup 3+}-doped colloidal SiO{sub 2} composite abrasives and the silica cores were coated by shells (which contains SiO{sub 2}, Nd{sub 2}Si{sub 2}O{sub 7} and Nd(OH){sub 3}) via chemical bonds and hydrogen bonds in the Nd{sup 3+}-doped colloidal SiO{sub 2} composite abrasives, which made the composite abrasives’ core-shell structure more sTable Scanning electron microscopy (SEM) showed that Nd{sup 3+}-doped colloidal SiO{sub 2} composite abrasives were spherical and uniform in size. And the acting mechanisms of Nd{sup 3+}-doped colloidal SiO{sub 2} composite abrasives on sapphire in CMP were investigated. Time-of-flight secondary ion mass spectroscopy (TOF-SIMS) analysis and X-ray photoelectron spectroscopy (XPS) analysis demonstrated that the solid-state chemical reactions between the shells (which contained SiO{sub 2}, Nd{sub 2}Si{sub 2}O{sub 7} and Nd(OH){sub 3}) of Nd{sup 3+}-doped colloidal SiO{sub 2} composite abrasives and the sapphire occurred during the CMP process. Furthermore, Nd{sup 3+}-doped colloidal SiO{sub 2} composite abrasives exhibited lower surface roughness and

  17. Multicenter study in monitoring central venous catheters complications in hematologic patiennts

    Directory of Open Access Journals (Sweden)

    Carmen García Gabás

    2013-05-01

    Full Text Available Most hematological patients suffer a significant venous damage related to different administrated intravenous therapy, being necessary to place central venous catheters (CVC. CVC is associated with various complications. The most common catheter-related complications are occlusion and infection. To avoid such of them, the development of protocols for insertion and care are needed, as well as recording and following up complications. To this end, we propose a cross-sectional carried out during 13 months whose main goal is to know the incidence of CVC- related complications (mainly occlusion and infection in hematological patients.Population included all the =14 ages patients admitted to different hematological units at Ramon y Cajal and Gregorio Marañón hospitals in Madrid and who signed informed consent. Socio-demographic, clinical characteristics and complications were entered into a log which included a pursuit of care protocol.

  18. Structural characterization of ZnO films grown by molecular beam epitaxy on sapphire with MgO buffer

    International Nuclear Information System (INIS)

    Pecz, B.; El-Shaer, A.; Bakin, A.; Mofor, A.-C.; Waag, A.; Stoemenos, J.

    2006-01-01

    The structural characteristics of the ZnO film grown on sapphire substrate using a thin MgO buffer layer were studied using transmission electron microscopy and high-resolution x-ray diffraction. The growth was carried out in a modified plasma-molecular beam epitaxy system. The observed misfit dislocations were well confined at the sapphire overgrown interface exhibiting domain matching epitaxy, where the integral multiples of lattice constants match across the interface. The main extended defects in the ZnO film were the threading dislocations having a mean density of 4x10 9 cm -2 . The formation of the MgO buffer layer as well as the ZnO growth were monitored in situ by reflection high-energy electron diffraction. The very thin ∼1 nm, MgO buffer layer can partially interdiffuse with the ZnO as well as react with the Al 2 O 3 substrate forming an intermediate epitaxial layer having the spinel (MgO/Al 2 O 3 ) structure

  19. Evidence of selective reporting bias in hematology journals: A systematic review.

    Science.gov (United States)

    Wayant, Cole; Scheckel, Caleb; Hicks, Chandler; Nissen, Timothy; Leduc, Linda; Som, Mousumi; Vassar, Matt

    2017-01-01

    Selective reporting bias occurs when chance or selective outcome reporting rather than the intervention contributes to group differences. The prevailing concern about selective reporting bias is the possibility of results being modified towards specific conclusions. In this study, we evaluate randomized controlled trials (RCTs) published in hematology journals, a group in which selective outcome reporting has not yet been explored. Our primary goal was to examine discrepancies between the reported primary and secondary outcomes in registered and published RCTs concerning hematological malignancies reported in hematology journals with a high impact factor. The secondary goals were to address whether outcome reporting discrepancies favored statistically significant outcomes, whether a pattern existed between the funding source and likelihood of outcome reporting bias, and whether temporal trends were present in outcome reporting bias. For trials with major outcome discrepancies, we contacted trialists to determine reasons for these discrepancies. Trials published between January 1, 2010 and December 31, 2015 in Blood; British Journal of Haematology; American Journal of Hematology; Leukemia; and Haematologica were included. Of 499 RCTs screened, 109 RCTs were included. Our analysis revealed 118 major discrepancies and 629 total discrepancies. Among the 118 discrepancies, 30 (25.4%) primary outcomes were demoted, 47 (39.8%) primary outcomes were omitted, and 30 (25.4%) primary outcomes were added. Three (2.5%) secondary outcomes were upgraded to a primary outcome. The timing of assessment for a primary outcome changed eight (6.8%) times. Thirty-one major discrepancies were published with a P-value and twenty-five (80.6%) favored statistical significance. A majority of authors whom we contacted cited a pre-planned subgroup analysis as a reason for outcome changes. Our results suggest that outcome changes occur frequently in hematology trials. Because RCTs ultimately

  20. Hematological parameters of human immunodeficiency virus positive pregnant women on antiretroviral therapy in Aminu Kano Teaching Hospital Kano, North Western Nigeria.

    Science.gov (United States)

    Abdulqadir, Ibrahim; Ahmed, Sagir Gumel; Kuliya, Aisha Gwarzo; Tukur, Jamilu; Yusuf, Aminu Abba; Musa, Abubakar Umar

    2018-01-01

    Human immunodeficiency virus (HIV) scourge continues to affect young women within the reproductive age group and pregnancy is a recognized indication for the use antiretroviral (ARV) drugs among HIV-positive women. The aim is to determine the combined effect of pregnancy, HIV and ARV drugs on the hematological parameters of the pregnant women. This was a comparative cross-sectional study conducted among 70 each of HIV-positive and negative pregnant women. Bio-demographic and clinical data were extracted from the client folder and 4 ml of blood sample was obtained from each participant. Full blood count was generated using Swelab automatic hematology analyzer while reticulocyte count and erythrocyte sedimentation rate (ESR) were conducted manually. Data analysis was performed using SPSS version software 16 while P women with HIV had statistically significant lower hematocrit and white blood cell (WBC) and higher ESR than pregnant women without HIV ( P 0.05). However, among HIV positive pregnant women, those with CD4 count 0.050) between women on first- and second-line ARV regimens. There is a significant difference in terms of hematological parameters between HIV-positive and HIV-negative pregnant women in this environment.

  1. Results of candidemia treatment in children with hematologic malignancies: single center experience

    Directory of Open Access Journals (Sweden)

    I. I. Kalinina

    2014-07-01

    Full Text Available Candidemia is one of the most serious infectious complications in children with hematological malignancies and has a high morta lity rate.Seven-year experience of candidemia diagnosis and therapy in patients with various hematologic malignancies w as analyzed. Candidemia registered in 37 patients (AML and MDS — 14, ALL — 10, solid tumors — 5, histocytic syndromes — 4, AA — 3, other non-malignancy diseases— 2. C. non-albicans (36 isolates from 32 patients was common cause of, while C. albicans isolated in 5 patients (8 strains. Antifungal prophylactic therapy was applied to 31 patients. 22 patients at the time of candidemia have neutropenia (< 0.5 × 10 9/l. Main clinical manifestations were febrile fever (100 % cases and pneumonia (21.6 % cases. Less frequent multiorgan failure (8.1 %, septic shoc k (5.4 %, chronic disseminated candidiasis (5.4 % and meningitis (2.7 % were registered. All patients received antifungal therapy (monotherapy — 17, combination therapy — 20. Central venous catheter removed in 21 patients. In 14 patients hematopoietic recovery w as registered, none of these patients died, while from group of patients without hematopoietic recovery 6 patients died (p = 0.0001. Recurrent candidemia episodes were seen in 4 patients. Overall survival was 0.37 ± 0.09.

  2. Pattern of hematological malignancies in adolescents and young adults in Bangladesh.

    Science.gov (United States)

    Hasan, Md Mahbub; Raheem, Enayetur; Sultana, Tanvira Afroze; Hossain, Mohammad Sorowar

    2017-12-01

    The adolescent and young adult (AYA) age group (15-39 years) bears distinct characteristics in terms of cancer biology, long-term health and treatment-related complications and psychosocial aspects. The overall scenario of cancer including hematological malignancies (HMs) is largely unknown in Bangladesh, where a significant proportion of people (44% of total population) belong to AYA age group. This study aims to describe the patterns of HM among AYA in the context of Bangladesh METHODS: Two previously published datasets (on hematological malignancies and childhood and adolescent cancer) were merged to construct a comprehensive dataset focusing exclusively on HMs in AYA age group. Univariate descriptive statistics were calculated and bivariate association were tested using Pearson's Chi-square test. A total of 2144 diagnosed HM related cases over a period of 2007-2014 were analyzed. Acute myeloid leukemia (AML) was the most frequent HM (35.1%) in AYAs, which was followed by acute lymphoblastic leukemia (ALL) and chronic myeloid leukemia (CML) constituting 22.7% and 20.8%, respectively. Among lymphomas, Non-Hodgkin lymphoma (NHL) constituted 13.9% of all HMs while 4.6% was for Hodgkin's lymphoma (HL). This is the first attempt to provide a glimpse on the pattern and distribution of HMs among AYA in Bangladesh. Future studies are essential to get a better insight on the epidemiology, biology, potential risk factors and treatment outcomes for the AYA age group. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Hematology, cytochemistry and ultrastructure of blood cells in fishing cat (Felis viverrina)

    OpenAIRE

    Prihirunkit, Kreangsak; Salakij, Chaleow; Apibal, Suntaree; Narkkong, Nual-Anong

    2007-01-01

    Hematological, cytochemical and ultrastructural features of blood cells in fishing cat (Felis viverrina) were evaluated using complete blood cell counts with routine and cytochemical blood stains, and scanning and transmission electron microscopy. No statistically significant difference was found in different genders of this animal. Unique features of blood cells in this animal were identified in hematological, cytochemical and ultrastructural studies. This study contributes to broaden hemato...

  4. Molt-associated changes in hematologic and plasma biochemical values and stress hormone levels in African penguins (Spheniscus demersus).

    Science.gov (United States)

    Mazzaro, Lisa M; Meegan, Jenny; Sarran, Delphine; Romano, Tracy A; Bonato, Vinicius; Deng, Shibing; Dunn, J Lawrence

    2013-12-01

    Handling, including blood collection, has often been discouraged in molting penguins because it is considered an additional stress imposed on birds already experiencing major physiologic stress associated with molting. To evaluate the degree of physiologic stress posed by molting, we compared the hematologic and plasma biochemical values and hormone levels of molting and nonmolting African penguins, Spheniscus demersus. Five male and 5 female penguins randomly chosen were given complete physical examinations, were weighed, and blood samples were taken at 7 time points before, during, and after the molt. Data were analyzed by linear mixed-model analysis of variance. Throughout the study, behavior and appetite remained normal. Catecholamine levels were highly variable within and among subjects, whereas mean corticosterone levels were significantly different between baseline, molt, and postmolt values. Significant differences from baseline values were observed in many of the hematologic analytes; however, only decreases in hematocrit and red blood cell count values were considered clinically significant. Anemia due to experimentally induced blood loss as a possible cause of the significant hematologic changes was ruled out based on results of a follow-up control study during the nonmolt season, which showed no significant changes in hematocrit level or total red blood cell counts when using similar sampling protocols, which indicates that these changes were associated with molt.

  5. Single phase semipolar (11 anti 22) GaN on (10 anti 10) sapphire

    Energy Technology Data Exchange (ETDEWEB)

    Ploch, S.; Stellmach, J.; Schwaner, T.; Frentrup, M.; Wernicke, T.; Pristovsek, M.; Kneissl, M. [Institute of Solid States Physics, (Germany); Park, J.B.; Niermann, T.; Lehmann, M. [Institute of Optics and Atomic Physics, TU Berlin, Hardenbergstr. 36, 10623 Berlin (Germany)

    2011-07-01

    InGaN quantum well based light emitters grown on (0001) GaN suffer from poor quantum efficiencies with increasing indium mole fraction due to strong polarization fields along the polar crystal orientation. This effect can be greatly reduced by growing on semi- and non-polar GaN orientations. Semipolar (11 anti 22) GaN layers were deposited by metalorganic vapour phase epitaxy on (10 anti 10) sapphire. After sapphire substrate nitridation at 1000 C, a GaN nucleation layer was deposited at high temperature, followed by the deposition of 1.5 nm thick GaN buffer layers. The samples show predominantly (11 anti 22) orientation with a small fraction of (10 anti 13) oriented domains. With increasing nitridation layer thickness the (10 anti 13) phase is suppressed leading to a very smooth surface morphology (rms roughness < 4nm). PL measurements show dominant basel plane stacking fault (BSF) I{sub 1} luminescence without any other defects. Transmission electron microscopy measurements reveal a high BSF density. The FWHM of the X-ray diffraction rocking curve measurements of the (1122) reflection decreases to 1193 arcsec and 739 arcsec along [1 anti 100] and [11 anti 23] respectively with increasing nucleation temperature. Using high temperature nucleation smooth and homogeneous (11 anti 22) phase GaN layers have been obtained.

  6. Profile of hematological abnormalities of Indian HIV infected individuals

    Directory of Open Access Journals (Sweden)

    Sharma Aman

    2009-08-01

    Full Text Available Abstract Background Hematological abnormalities are a common complication of HIV infection. These abnormalities increase as the disease advances. Bone marrow abnormalities occur in all stages of HIV infection. Methods Two hundred HIV infected individual were screened for hematological abnormalities from March 2007–March 2008. Absolute CD4 cell count analysis was carried out by flowcytometry. Depending on the results of the primary screening further investigations were performed, like iron studies, hemolytic work up, PNH work up and bone marrow evaluation. Other investigations included coagulation profile, urine analysis, blood culture (bacterial, fungal, mycobacterial, serology for Epstein Barr virus (EBV, Cytomegalovirus (CMV, Hepatitis B and C, and Parvo B19 infection. Results The most common hematological abnormality was anemia, seen in 65.5% (131/200 patients. Iron deficiency anemia was seen in 49.2% (/200 cases while anemia of chronic disease occurred in 50.7% (/200 cases. Bone marrow evaluation was carried out in 14 patients out of which staging marrow was performed in 2 cases of non-Hodgkin's lymphoma (NHL and did not show any bone marrow infiltration. In remaining12 cases bone marrow was done for evaluation of pancytopenia. Among patients with pancytopenia 50% (6/12 showed granulomas (4 were positive for AFB, 2 were positive for fungal cryptococci, 25% (3/12 showed hemophagocytosis. There was a strong negative correlation between anemia and CD4 counts in this study. Thrombocytopenia was seen in 7% (14/200 cases and had no significant correlation with CD4 counts. No patient had absolute neutrophil count (ANC Conclusion Anemia in HIV patients can be a good clinical indicator to predict and access the underlying immune status. Patients should be investigated for hematological manifestations and appropriate steps should be taken to identify and treat the reversible factors.

  7. Assembly and evaluation of an inventory of guidelines that are available to support clinical hematology laboratory practice.

    Science.gov (United States)

    Hayward, C P M; Moffat, K A; George, T I; Proytcheva, M

    2015-05-01

    Practice guidelines provide helpful support for clinical laboratories. Our goal was to assemble an inventory of publically listed guidelines on hematology laboratory topics, to create a resource for laboratories and for assessing gaps in practice-focused guidelines. PubMed and website searches were conducted to assemble an inventory of hematology laboratory-focused guidelines. Exclusions included annual, technical, or collaborative study reports, clinically focused guidelines, position papers, nomenclature, and calibration documents. Sixty-eight guidelines were identified on hematology laboratory practice topics from 12 organizations, some as joint guidelines. The median year of publication was 2010 and 15% were >10 years old. Coagulation topics had the largest numbers of guidelines, whereas some areas of practice had few guidelines. A minority of guidelines showed evidence of periodic updates, as some organizations did not remove or identify outdated guidelines. This inventory of current practice guidelines will encourage awareness and uptake of guideline recommendations by the worldwide hematology laboratory community, with the International Society for Laboratory Hematology facilitating ongoing updates. There is a need to encourage best guideline development practices, to ensure that hematology laboratory community has current, high-quality, and evidence-based practice guidelines that cover the full scope of hematology laboratory practice. © 2015 John Wiley & Sons Ltd.

  8. Diurnal variation of hematology parameters in healthy young males: the Bispebjerg study of diurnal variations

    DEFF Research Database (Denmark)

    Sennels, Henriette P; Jørgensen, Henrik L; Hansen, Anne-Louise S

    2011-01-01

    To evaluate the influence of time of day on the circulating concentrations of 21 hematology parameters.......To evaluate the influence of time of day on the circulating concentrations of 21 hematology parameters....

  9. Eosinophilia in routine blood samples and the subsequent risk of hematological malignancies and death

    DEFF Research Database (Denmark)

    Andersen, Christen Bertel L; Siersma, Volkert Dirk; Hasselbalch, HC

    2013-01-01

    Eosinophilia may represent an early paraclinical sign of hematological malignant disease, but no reports exist on its predictive value for hematological malignancies. From the Copenhagen Primary Care Differential Count (CopDiff) Database, we identified 356,196 individuals with at least one differ...

  10. Acute hematologic emergencies in oncology

    International Nuclear Information System (INIS)

    Kristof, L.

    2012-01-01

    Malignant disease and its treatment are often being complicated by development of serious and at times life-threatening emergencies. Early recognition and treatment of these acute events are important to reduce morbidity and mortality in cancer patients. The following article provides an overview of several hematologic emergencies, which occur due abnormal hemopoiesis (e.g. hyperleukocytosis, anemia, thrombocytopenia), abnormal hemo stasis (e.g. hemorrhage, pulmonary embolism, disseminated intravascular coagulation), or are related to blood products transfusions (transfuse reactions). (author)

  11. Hematological parameters and prevalence of anemia among free-living elderly in south Brazil

    Directory of Open Access Journals (Sweden)

    Vanessa Sgnaolin

    2013-01-01

    Full Text Available OBJECTIVE: The aims of this study were to analyze the hematological parameters, the prevalence of anemia and the association between anemia and socioeconomic conditions in an elderly community-based population. METHODS: A population-based study was performed as part of the Multidimensional Study of the Elderly in Porto Alegre, Brazil (EMIPOA. An initial total of 1058 community residents aged 60 years and older were interviewed. Of these, 392 agreed to have a physical evaluation and a blood sample was taken from each. The hematological parameters analyzed in the blood samples included the hemoglobin concentration, mean cell volume (MCV, mean corpuscular hemoglobin concentration (MCHC and red cell distribution width (RDW. The association between the variables and the diagnosis of anemia was assessed using the chi-squared test and a multiple logistic regression model. RESULTS: The overall prevalence of anemia was 12.8%. Anemia was present in 13.7% of women and in 10.4% of men. Normocytic normochromic anemia without anisocytosis was the most common type of anemia (46%. The assessment of erythrocyte morphology showed significant differences between anemic and non-anemic individuals (microcytosis = 12% vs. 1.5%, hypochromia = 40% vs. 8.8%, and anisocytosis = 26% vs. 7%. In the analysis of socioeconomic conditions, significant differences were found in respect to age and race. CONCLUSION: The prevalence of anemia increases with age and is associated with race, microcytosis, hypochromia and anisocytosis. Anemia is not a condition that should be associated only with the aging process, as it may be due to pathological conditions that occur most frequently in this age group. As a result, a diagnosis of anemia warrants adequate clinical attention.

  12. Female Representation in the Academic Oncology Physician Workforce: Radiation Oncology Losing Ground to Hematology Oncology

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Awad A. [Sylvester Comprehensive Cancer Center University of Miami Health System, Miami, Florida (United States); Hwang, Wei-Ting [Department of Biostatistics and Epidemiology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Holliday, Emma B. [Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Chapman, Christina H.; Jagsi, Reshma [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Thomas, Charles R. [Department of Radiation Medicine, Knight Cancer Institute, Oregon Health & Science University, Portland, Oregon (United States); Deville, Curtiland, E-mail: cdeville@jhmi.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland (United States)

    2017-05-01

    Purpose: Our purpose was to assess comparative female representation trends for trainees and full-time faculty in the academic radiation oncology and hematology oncology workforce of the United States over 3 decades. Methods and Materials: Simple linear regression models with year as the independent variable were used to determine changes in female percentage representation per year and associated 95% confidence intervals for trainees and full-time faculty in each specialty. Results: Peak representation was 48.4% (801/1654) in 2013 for hematology oncology trainees, 39.0% (585/1499) in 2014 for hematology oncology full-time faculty, 34.8% (202/581) in 2007 for radiation oncology trainees, and 27.7% (439/1584) in 2015 for radiation oncology full-time faculty. Representation significantly increased for trainees and full-time faculty in both specialties at approximately 1% per year for hematology oncology trainees and full-time faculty and 0.3% per year for radiation oncology trainees and full-time faculty. Compared with radiation oncology, the rates were 3.84 and 2.94 times greater for hematology oncology trainees and full-time faculty, respectively. Conclusion: Despite increased female trainee and full-time faculty representation over time in the academic oncology physician workforce, radiation oncology is lagging behind hematology oncology, with trainees declining in recent years in radiation oncology; this suggests a de facto ceiling in female representation. Whether such issues as delayed or insufficient exposure, inadequate mentorship, or specialty competitiveness disparately affect female representation in radiation oncology compared to hematology oncology are underexplored and require continued investigation to ensure that the future oncologic physician workforce reflects the diversity of the population it serves.

  13. Female Representation in the Academic Oncology Physician Workforce: Radiation Oncology Losing Ground to Hematology Oncology

    International Nuclear Information System (INIS)

    Ahmed, Awad A.; Hwang, Wei-Ting; Holliday, Emma B.; Chapman, Christina H.; Jagsi, Reshma; Thomas, Charles R.; Deville, Curtiland

    2017-01-01

    Purpose: Our purpose was to assess comparative female representation trends for trainees and full-time faculty in the academic radiation oncology and hematology oncology workforce of the United States over 3 decades. Methods and Materials: Simple linear regression models with year as the independent variable were used to determine changes in female percentage representation per year and associated 95% confidence intervals for trainees and full-time faculty in each specialty. Results: Peak representation was 48.4% (801/1654) in 2013 for hematology oncology trainees, 39.0% (585/1499) in 2014 for hematology oncology full-time faculty, 34.8% (202/581) in 2007 for radiation oncology trainees, and 27.7% (439/1584) in 2015 for radiation oncology full-time faculty. Representation significantly increased for trainees and full-time faculty in both specialties at approximately 1% per year for hematology oncology trainees and full-time faculty and 0.3% per year for radiation oncology trainees and full-time faculty. Compared with radiation oncology, the rates were 3.84 and 2.94 times greater for hematology oncology trainees and full-time faculty, respectively. Conclusion: Despite increased female trainee and full-time faculty representation over time in the academic oncology physician workforce, radiation oncology is lagging behind hematology oncology, with trainees declining in recent years in radiation oncology; this suggests a de facto ceiling in female representation. Whether such issues as delayed or insufficient exposure, inadequate mentorship, or specialty competitiveness disparately affect female representation in radiation oncology compared to hematology oncology are underexplored and require continued investigation to ensure that the future oncologic physician workforce reflects the diversity of the population it serves.

  14. Female Representation in the Academic Oncology Physician Workforce: Radiation Oncology Losing Ground to Hematology Oncology.

    Science.gov (United States)

    Ahmed, Awad A; Hwang, Wei-Ting; Holliday, Emma B; Chapman, Christina H; Jagsi, Reshma; Thomas, Charles R; Deville, Curtiland

    2017-05-01

    Our purpose was to assess comparative female representation trends for trainees and full-time faculty in the academic radiation oncology and hematology oncology workforce of the United States over 3 decades. Simple linear regression models with year as the independent variable were used to determine changes in female percentage representation per year and associated 95% confidence intervals for trainees and full-time faculty in each specialty. Peak representation was 48.4% (801/1654) in 2013 for hematology oncology trainees, 39.0% (585/1499) in 2014 for hematology oncology full-time faculty, 34.8% (202/581) in 2007 for radiation oncology trainees, and 27.7% (439/1584) in 2015 for radiation oncology full-time faculty. Representation significantly increased for trainees and full-time faculty in both specialties at approximately 1% per year for hematology oncology trainees and full-time faculty and 0.3% per year for radiation oncology trainees and full-time faculty. Compared with radiation oncology, the rates were 3.84 and 2.94 times greater for hematology oncology trainees and full-time faculty, respectively. Despite increased female trainee and full-time faculty representation over time in the academic oncology physician workforce, radiation oncology is lagging behind hematology oncology, with trainees declining in recent years in radiation oncology; this suggests a de facto ceiling in female representation. Whether such issues as delayed or insufficient exposure, inadequate mentorship, or specialty competitiveness disparately affect female representation in radiation oncology compared to hematology oncology are underexplored and require continued investigation to ensure that the future oncologic physician workforce reflects the diversity of the population it serves. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Effects of maternal dexamethasone exposure on hematological ...

    African Journals Online (AJOL)

    Exposure to dexamethasone at LD 1-14 and 1-21 significantly (P<0.05) reduced RBC and platelet counts but it raised MCV and MCH relative to control. This study suggests that prenatal and lactational dexamethasone administration may affect the hematological indices in the male offspring. Keywords: Dexamethasone ...

  16. Computerized tomography in the study of intracranial complications in hematology

    International Nuclear Information System (INIS)

    Gastaut, J.L.; Gastaut, J.A.

    1979-01-01

    CT was used to examine 100 patients with various hematologic disorders. It was generally in patients with clinical signs of encephalic alteration (68% of the cases) that we demonstrated lesions. In several cases, the lesions were detected by CT, whereas common neurological investigational methods remained negative. The most interesting findings were in acute leukemias (leucoblastic infiltrations, cerebral hemorrhages and infarctions, and iatrogenic morphologic modifications) and in Hodgkin diseases (intracranial localizations). CT permits a more complete neurologic work-up for patients with hematologic disorders and provides a better knowledge of the frequency and varieties of intracranial complications. (orig.) 891 MG/orig. 892 MB [de

  17. Hematology of healthy Florida manatees (Trichechus manatus)

    Science.gov (United States)

    Harvey, J.W.; Harr, K.E.; Murphy, D.; Walsh, M.T.; Nolan, E.C.; Bonde, R.K.; Pate, M.G.; Deutsch, C.J.; Edwards, H.H.; Clapp, W.L.

    2009-01-01

    Background: Hematologic analysis is an important tool in evaluating the general health status of free-ranging manatees and in the diagnosis and monitoring of rehabilitating animals. Objectives: The purpose of this study was to evaluate diagnostically important hematologic analytes in healthy manatees (Trichechus manatus) and to assess variations with respect to location (free ranging vs captive), age class (small calves, large calves, subadults, and adults), and gender. Methods: Blood was collected from 55 free-ranging and 63 captive healthy manatees. Most analytes were measured using a CELL-DYN 3500R; automated reticulocytes were measured with an ADVIA 120. Standard manual methods were used for differential leukocyte counts, reticulocyte and Heinz body counts, and plasma protein and fibrinogen concentrations. Results: Rouleaux, slight polychromasia, stomatocytosis, and low numbers of schistocytes and nucleated RBCs (NRBCs) were seen often in stained blood films. Manual reticulocyte counts were higher than automated reticulocyte counts. Heinz bodies were present in erythrocytes of most manatees. Compared with free-ranging manatees, captive animals had slightly lower MCV, MCH, and eosinophil counts and slightly higher heterophil and NRBC counts, and fibrinogen concentration. Total leukocyte, heterophil, and monocyte counts tended to be lower in adults than in younger animals. Small calves tended to have higher reticulocyte counts and NRBC counts than older animals. Conclusions: Hematologic findings were generally similar between captive and free-ranging manatees. Higher manual reticulocyte counts suggest the ADVIA detects only reticulocytes containing large amounts of RNA. Higher reticulocyte and NRBC counts in young calves probably reflect an increased rate of erythropoiesis compared with older animals. ?? 2009 American Society for Veterinary Clinical Pathology.

  18. The PIM kinases in hematological cancers.

    Science.gov (United States)

    Alvarado, Yesid; Giles, Francis J; Swords, Ronan T

    2012-02-01

    The PIM genes represent a family of proto-oncogenes that encode three different serine/threonine protein kinases (PIM1, PIM2 and PIM3) with essential roles in the regulation of signal transduction cascades, which promote cell survival, proliferation and drug resistance. PIM kinases are overexpressed in several hematopoietic tumors and support in vitro and in vivo malignant cell growth and survival, through cell cycle regulation and inhibition of apoptosis. PIM kinases do not have an identified regulatory domain, which means that these proteins are constitutively active once transcribed. They appear to be critical downstream effectors of important oncoproteins and, when overexpressed, can mediate drug resistance to available agents, such as rapamycin. Recent crystallography studies reveal that, unlike other kinases, they possess a hinge region, which creates a unique binding pocket for ATP, offering a target for an increasing number of potent small-molecule PIM kinase inhibitors. Preclinical studies in models of various hematologic cancers indicate that these novel agents show promising activity and some of them are currently being evaluated in a clinical setting. In this review, we profile the PIM kinases as targets for therapeutics in hematologic malignancies.

  19. Effect of coating thickness on interfacial shear behavior of zirconia-coated sapphire fibers in a polycrystalline alumina matrix

    International Nuclear Information System (INIS)

    Hellmann, J.R.; Chou, Y.S.

    1995-01-01

    The effect of zirconia (ZrO 2 ) interfacial coatings on the interfacial shear behavior in sapphire reinforced alumina was examined in this study. Zirconia coatings of thicknesses ranging from 0.15 to 1.45 μm were applied to single crystal sapphire (Saphikon) fibers using a particulate loaded sol dipping technique. After calcining at 1,100 C in air, the coated fibers were incorporated into a polycrystalline alumina matrix via hot pressing. Interfacial shear strength and sliding behavior of the coated fibers was examined using thin-slice indentation fiber pushout and pushback techniques. In all cases, debonding and sliding occurred at the interface between the fibers and the coating. The coatings exhibited a dense microstructure and led to a higher interfacial shear strength (> 240 MPa) and interfacial sliding stress (> 75 MPa) relative to previous studies on the effect of a porous interphase on interfacial properties. The interfacial shear strength decreased with increasing fiber coating thickness (from 389 ± 59 to 241 ± 43 MPa for 0.15 to 1.45 microm thick coatings, respectively). Sliding behavior exhibited load modulation with increasing displacement during fiber sliding which is characteristic of fiber roughness-induced stick-slip. The high interfacial shear strengths and sliding stresses measured in this study, as well as the potentially strength degrading surface reconstruction observed on the coated fibers after hot pressing and heat treatment, indicate that dense zirconia coatings are not suitable candidates for optimizing composite toughness and strength in the sapphire fiber reinforced alumina system

  20. The active control devices of the size of products based on sapphire measuring tips with three degrees of freedom

    Science.gov (United States)

    Leun, E. V.; Leun, V. I.; Sysoev, V. K.; Zanin, K. A.; Shulepov, A. V.; Vyatlev, P. A.

    2018-01-01

    The article presents the results of the calculation of the load capacity of the active control devices (ACD) sapphire tip, which showed nearly 30-fold margin of safety to shock loads and experimental researches in mechanical contact with 5 cogs cutter 15 mm in diameter rotating with a frequency of 1000 rpm, which confirmed the calculations, determined the surface roughness Rz of the contact area of no more than 0.15 μm. Conditions have been created for recording without distortion of the image through a sapphire tip in contact with the processed article. A ACD design with new functionality is proposed: with one, two and three degrees of freedom of the sapphire tip and allows measuring the taper of the article and measurements on the chord. It is shown that with the implementation of their fixed head like the frame of the gyroscope with the rotations around the axes OY and OZ. It is shown that the rotation of the tip around the axis OX can be replaced more convenient for the implementation of the angular offset of the transferred image due to rotation of the output end of the flexible optical waveguide relative to the input. This makes it possible to reduce the "blurring of the image" during registration of the fast moving product profile when the slope of the recorder lines coincides with the slope of the edges of the image elements of the selected moving elements of the article.

  1. Exploring communication difficulties in pediatric hematology: oncology nurses.

    Science.gov (United States)

    Citak, Ebru Akgun; Toruner, Ebru Kilicarslan; Gunes, Nebahat Bora

    2013-01-01

    Communication plays an important role for the well being of patients, families and also health care professionals in cancer care. Conversely, ineffective communication may cause depression, increased anxiety, hopelessness and decreased of quality life for patients, families and also nurses. This study aimed to explore communication difficulties of pediatric hematology/oncology nurses with patients and their families, as well as their suggestions about communication difficulties. It was conducted in a pediatric hematology/oncology hospital in Ankara, Turkey. Qualitative data were collected by focus groups, with 21 pediatric hematology/oncology nursing staff from three groups. Content analysis was used for data analysis. Findings were grouped in three main categories. The first category concerned communication difficulties, assessing problems in responding to questions, ineffective communication and conflicts with the patient's families. The second was about the effects of communication difficulties on nurses and the last main category involved suggestions for empowering nurses with communication difficulties, the theme being related to institutional issues. Nurses experience communication difficulties with children and their families during long hospital stays. Communication difficulties particularly increase during crisis periods, like at the time of first diagnosis, relapse, the terminal stage or on days with special meaning such as holidays. The results obtained indicate that pediatric nurses and the child/family need to be supported, especially during crisis periods. Feeling of empowerment in communication will improve the quality of care by reducing the feelings of exhaustion and incompetence in nurses.

  2. Hematological and Serum Biochemical Parameters of Weanling ...

    African Journals Online (AJOL)

    The objective of this study was to determine the dose-dependent effect of medroxyprogesterone acetate on hematology and serum biochemistry in weanling dogs. Nine healthy local dogs between 12 to 14 weeks of age were randomly assigned to three treatments: control, 150mg/kg and 300mg/kg of medroxyprogesterone ...

  3. Hematologic features among anemic Cameroonian pregnant women

    African Journals Online (AJOL)

    Introduction: iron deficiency anemia is the leading cause of anemia worldwide. It may also be the leading cause of anemia in pregnancy, although this has not yet been demonstrated in our country. The aim of the study was to describe hematologic features of Cameroonian anemic pregnant women. Methods: this cross ...

  4. Single-crystalline AlN growth on sapphire using physical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas-Valencia, Andres M., E-mail: andres.cardenas@sri.co [SRI International (United States); Onishi, Shinzo; Rossie, Benjamin [SRI International (United States)

    2011-02-07

    A novel technique for growing single crystalline aluminum nitride (AlN) films is presented. The novelty of the technique, specifically, comes from the use of an innovative physical vapor deposition magnetron sputtering tool, which embeds magnets into the target material. A relatively high deposition rates is achieved ({approx}0.2 {mu}m/min), at temperatures between 860 and 940 {sup o}C. The AlN, grown onto sapphire, is single-crystalline as evidenced by observation using transmission electron microscopy. Tool configuration and growth conditions are discussed, as well as a first set of other analytical results, namely, x-ray diffraction and ultraviolet-visible transmission spectrophotometry.

  5. Association between PER3 length polymorphism and onco-hematological diseases and its influences on patients' functionality

    Directory of Open Access Journals (Sweden)

    María Belén Cerliani

    2015-12-01

    Full Text Available Circadian clock gene PER3 and its length polymorphism may have a role in oncogenesis as clock genes act as key regulators of cell cycle and DNA repair pathways. The polymorphism may affect the condition of patients who show disrupted circadian rhythm due to tumor development. The aim was to assess the association between PER3 polymorphism and onco-hematological diseases, and analyze whether this variant has an impact on patient’s functionality. We conducted a case-control study on 125 patients with onco-hematological diseases and 310 control patients. PER3 allelic variants were detected by using polymerase chain reaction. Sociodemographic data and information on patient’s habits and functionality were obtained through questionnaire. Genotypes 4/5 + 5/5 showed an odd ratio (OR = 1.39, with no statistical significance. However, those genotypes were associated with a two-fold increase in the risk of acute/chronic lymphoblastic/myeloblastic leukemia, taken all together. The occurrence of “changes in humor during last two months” was significantly associated with onco-hematological diseases. “Fatigue on awakening” and “self-reported snore” were associated with cases carrying the 4/5 or 5/5 genotypes. The results suggested that PER3 polymorphism may have a role in the risk of leukemia, and might be a possible marker for individual differences in susceptibility to sleep disruption. This work provides insights for the identification of individuals at high risk of cancer, and those who are more susceptible to circadian disruption, which may decrease the physiological defenses against the tumor.

  6. Subwavelength engineered fiber-to-chip silicon-on-sapphire interconnects for mid-infrared applications (Conference Presentation)

    Science.gov (United States)

    Alonso-Ramos, Carlos; Han, Zhaohong; Le Roux, Xavier; Lin, Hongtao; Singh, Vivek; Lin, Pao Tai; Tan, Dawn; Cassan, Eric; Marris-Morini, Delphine; Vivien, Laurent; Wada, Kazumi; Hu, Juejun; Agarwal, Anuradha; Kimerling, Lionel C.

    2016-05-01

    The mid-Infrared wavelength range (2-20 µm), so-called fingerprint region, contains the very sharp vibrational and rotational resonances of many chemical and biological substances. Thereby, on-chip absorption-spectrometry-based sensors operating in the mid-Infrared (mid-IR) have the potential to perform high-precision, label-free, real-time detection of multiple target molecules within a single sensor, which makes them an ideal technology for the implementation of lab-on-a-chip devices. Benefiting from the great development realized in the telecom field, silicon photonics is poised to deliver ultra-compact efficient and cost-effective devices fabricated at mass scale. In addition, Si is transparent up to 8 µm wavelength, making it an ideal material for the implementation of high-performance mid-IR photonic circuits. The silicon-on-insulator (SOI) technology, typically used in telecom applications, relies on silicon dioxide as bottom insulator. Unfortunately, silicon dioxide absorbs light beyond 3.6 µm, limiting the usability range of the SOI platform for the mid-IR. Silicon-on-sapphire (SOS) has been proposed as an alternative solution that extends the operability region up to 6 µm (sapphire absorption), while providing a high-index contrast. In this context, surface grating couplers have been proved as an efficient means of injecting and extracting light from mid-IR SOS circuits that obviate the need of cleaving sapphire. However, grating couplers typically have a reduced bandwidth, compared with facet coupling solutions such as inverse or sub-wavelength tapers. This feature limits their feasibility for absorption spectroscopy applications that may require monitoring wide wavelength ranges. Interestingly, sub-wavelength engineering can be used to substantially improve grating coupler bandwidth, as demonstrated in devices operating at telecom wavelengths. Here, we report on the development of fiber-to-chip interconnects to ZrF4 optical fibers and integrated SOS

  7. Synthesis of single-crystalline Al layers in sapphire

    International Nuclear Information System (INIS)

    Schlosser, W.; Lindner, J.K.N.; Zeitler, M.; Stritzker, B.

    1999-01-01

    Single-crystalline, buried aluminium layers were synthesized by 180 keV high-dose Al + ion implantation into sapphire at 500 deg. C. The approximately 70 nm thick Al layers exhibit in XTEM investigations locally abrupt interfaces to the single-crystalline Al 2 O 3 top layer and bulk, while thickness and depth position are subjected to variations. The layers grow by a ripening process of oriented Al precipitates, which at low doses exist at two different orientations. With increasing dose, precipitates with one out of the two orientations are observed to exist preferentially, finally leading to the formation of a single-crystalline layer. Al outdiffusion to the surface and the formation of spherical Al clusters at the surface are found to be competing processes to buried layer formation. The formation of Al layers is described by Rutherford Backscattering Spectroscopy (RBS), Cross-section transmission electron microscopy (XTEM) and Scanning electron microscopy (SEM) studies as a function of dose, temperature and substrate orientation

  8. Preparation and modification of VO2 thin film on R-sapphire substrate by rapid thermal process

    Science.gov (United States)

    Zhu, Nai-Wei; Hu, Ming; Xia, Xiao-Xu; Wei, Xiao-Ying; Liang, Ji-Ran

    2014-04-01

    The VO2 thin film with high performance of metal-insulator transition (MIT) is prepared on R-sapphire substrate for the first time by magnetron sputtering with rapid thermal process (RTP). The electrical characteristic and THz transmittance of MIT in VO2 film are studied by four-point probe method and THz time domain spectrum (THz-TDS). X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and search engine marketing (SEM) are employed to analyze the crystalline structure, valence state, surface morphology of the film. Results indicate that the properties of VO2 film which is oxidized from the metal vanadium film in oxygen atmosphere are improved with a follow-up RTP modification in nitrogen atmosphere. The crystallization and components of VO2 film are improved and the film becomes compact and uniform. A better phase transition performance is shown that the resistance changes nearly 3 orders of magnitude with a 2-°C hysteresis width and the THz transmittances are reduced by 64% and 60% in thermal and optical excitation respectively.

  9. Managing work and cancer treatment: Experiences among survivors of hematological cancer.

    Science.gov (United States)

    Thomson, Maria D; Siminoff, Laura A

    2018-04-16

    The current study was performed to characterize the employment status of survivors of hematological cancer who have an informal caregiver from the time of diagnosis through the first 6 months of treatment. Using a mixed methods approach, semistructured interviews with survivors of hematological cancer were conducted within 6 months of the initiation of cancer treatment. Interviews assessed cancer treatment status, barriers and facilitators to employment, financial and insurance status, and relationship with the primary caregiver. These results are part of a longitudinal study of cancer survivors and informal caregivers. A total of 171 patients were enrolled. Within 6 months of beginning cancer treatments, approximately 35% were no longer employed. Reasons to remain employed included financial need, employee benefits, and a sense of purpose and normalcy. Employer accommodations and supportive colleagues facilitated continued employment. Logistic regression analysis demonstrated that having a higher household income, a desire to work, nonphysical job tasks, and congruent survivor-caregiver communication were associated with greater odds of remaining employed. Within 6 months of initiating cancer treatment, the majority of survivors of hematological cancer had maintained employment. Because of the limitations imposed by the physical stress of cancer treatments, as well as the need to maintain employment to continue receiving employee benefits to cover such treatments, survivors of hematological cancer likely would benefit from employment accommodations that are sensitive to their unique needs. Cancer 2018. © 2018 American Cancer Society. © 2018 American Cancer Society.

  10. Dispersion Free Doped and Undoped AlGaN/GaN HEMTs on Sapphire and SiC Substrates

    NARCIS (Netherlands)

    Kraemer, M.C.J.C.M.; Jacobs, B.; Kwaspen, J.J.M.; Suijker, E.M.; Hek, A.P. de; Karouta, F.; Kaufmann, L.M.F.; Hoskens, R.C.P.

    2004-01-01

    We present dispersion free pulsed current voltage (I-V) and radio frequency (RF) power results of undoped and doped AlGaN/GaN HEMTs on sapphire and SiC substrates. The most significant processing step leading to these results is the application of a reactive ion etching (RIE) argon (Ar) plasma

  11. Broadband single-transverse-mode fluorescence sources based on ribs fabricated in pulsed laser deposited Ti: sapphire waveguides

    NARCIS (Netherlands)

    Grivas, C.; May-Smith, T.C.; Shepherd, D.P.; Eason, R.W.; Pollnau, Markus; Jelinek, M.

    2004-01-01

    Active rib waveguides with depths and widths varying from 3 to 5 μm and from 9 to 24 μm, respectively, have been structured by $Ar^{+}$-beam etching in pulsed laser deposited Ti:sapphire layers. Losses in the channel structures were essentially at the same levels as the unstructured planar waveguide

  12. Hematologic disorders in trauma patients during parenteral alimentation with lipids.

    Science.gov (United States)

    Faintuch, J; Machado, F K; Freire, A N; Reis, J R; Machado, M; Pinto, L P; Ramos, S M; Loebens, M; Jovchelevich, V; Pinotti, H W

    1996-01-01

    Total parenteral nutrition with lipids is a well-accepted modality of metabolic support in seriously ill trauma patients. Intolerance to lipid administration is unusual when dosage limits are not exceeded, and few hematologic disturbances have been recorded with modern fat emulsions. In the course of intravenous alimentation of six adults admitted for traumatic lesions, eosinophilia with or without leukocytopenia was noticed after periods of four days to five weeks. Principal clinical events and hematologic derangements were documented in this population. Sepsis was not always present in the patients by the time of the complication, and in those that did require antibiotics and other drugs, the prescription remained unchanged along the episode. Discontinuation of the nutritional regimen with lipids was followed by normalization of the hematologic profile, suggesting that an acute or sub-acute allergic reaction was responsible. The appearance of skin rash in two occasions reinforces this hypothesis, and the possibility of hemophagocytosis merits consideration in two of the cases who displayed reversible acute leukocytopenia. It is concluded that blood cell aberrations are possible during intravenous feeding with lipids in trauma subjects, but tend to respond to suppression of the lipid-containing nutritional prescription.

  13. Artificial intelligence in hematology.

    Science.gov (United States)

    Zini, Gina

    2005-10-01

    Artificial intelligence (AI) is a computer based science which aims to simulate human brain faculties using a computational system. A brief history of this new science goes from the creation of the first artificial neuron in 1943 to the first artificial neural network application to genetic algorithms. The potential for a similar technology in medicine has immediately been identified by scientists and researchers. The possibility to store and process all medical knowledge has made this technology very attractive to assist or even surpass clinicians in reaching a diagnosis. Applications of AI in medicine include devices applied to clinical diagnosis in neurology and cardiopulmonary diseases, as well as the use of expert or knowledge-based systems in routine clinical use for diagnosis, therapeutic management and for prognostic evaluation. Biological applications include genome sequencing or DNA gene expression microarrays, modeling gene networks, analysis and clustering of gene expression data, pattern recognition in DNA and proteins, protein structure prediction. In the field of hematology the first devices based on AI have been applied to the routine laboratory data management. New tools concern the differential diagnosis in specific diseases such as anemias, thalassemias and leukemias, based on neural networks trained with data from peripheral blood analysis. A revolution in cancer diagnosis, including the diagnosis of hematological malignancies, has been the introduction of the first microarray based and bioinformatic approach for molecular diagnosis: a systematic approach based on the monitoring of simultaneous expression of thousands of genes using DNA microarray, independently of previous biological knowledge, analysed using AI devices. Using gene profiling, the traditional diagnostic pathways move from clinical to molecular based diagnostic systems.

  14. Oxamyl-induced alterations in hematological and biochemical parameters in rats

    International Nuclear Information System (INIS)

    Fayez, V.

    2003-01-01

    Effect of daily oral doses of 0.9 and 2.5 mg/kg of the carbamate insecticide oxamyl for 16 days on selected hematological and biochemical parameters in male rats was investigated. The weight of animals was significantly decreased compared to controls. The hematological studies revealed significant reduction in red blood cell count, hemoglobin and hematocrit values. Impairment of thyroid function was noticed by elevation of triiodothyronine (T 3 ) and depression of thyroxine (T 4 ). Brain acetylcholinesterase (AchE) was moderately inhibited in the first few days of exposure. However, the results of the parameters investigated indicate a moderate degree of toxicity of oxamyl following oral exposure of the doses selected

  15. Perceptions, attitudes, and experiences of hematology/oncology fellows toward incorporating geriatrics in their training.

    Science.gov (United States)

    Maggiore, Ronald J; Gorawara-Bhat, Rita; Levine, Stacie K; Dale, William

    2014-01-01

    The aging of the U.S. population continues to highlight emerging issues in providing care generally for older adults and specifically for older adults with cancer. The majority of patients with cancer in the U.S. are currently 65 years of age or older; therefore, training and research in geriatrics and geriatric oncology are viewed to be integral in meeting the needs of this vulnerable population. Yet, the ways to develop and integrate best geriatrics training within the context of hematology/oncology fellowship remain unclear. Toward this end, the current study seeks to evaluate the prior and current geriatric experiences and perspectives of hematology/oncology fellows. To gain insight into these experiences, focus groups of hematology/oncology fellows were conducted. Emergent themes included: 1) perceived lack of formal geriatric oncology didactics among fellows; 2) a considerable amount of variability exists in pre-fellowship geriatric experiences; 3) shared desire to participate in a geriatric oncology-based clinic; 4) differences across training levels in confidence in managing older adults with cancer; and 5) identification of specific criteria on how best to approach older adults with cancer in a particular clinical scenario. The present findings will help guide future studies in evaluating geriatrics among hematology/oncology fellows across institutions. They will also have implications in the development of geriatrics curricula and competencies specific to hematology/oncology training. © 2013.

  16. Pulsed high voltage discharge induce hematologic changes | El ...

    African Journals Online (AJOL)

    For basic hematology we determined the hematocrit (HCT), hemoglobin (HGB), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), and mean corpuscular hemoglobin concentration (MCHC). For differential blood count the number of red blood cells (RBC) and white blood cells (WBC), which were ...

  17. Carbamazepine - hematologic effects of the use

    Directory of Open Access Journals (Sweden)

    Kamil Leis

    2018-06-01

    Full Text Available Carbamazepine is an antiepileptic drug which exhibits a number of side effects, namely including a headache, abdominal pain, increased blood pressure, but also hematologic disorders. Thrombocytopenia, hypogammaglobulinemia, leukopenia, neutropenia, agranulocytosis, aplastic anemia, pure red cell aplasia, leukemia or eosinophilia with DRESS syndrome belong to the latter. There is a low incidence of carbamazepine pharmacotherapy related symptoms and their exact mechanisms of action are still unknown.

  18. Nanotechnology applications in hematological malignancies (Review).

    Science.gov (United States)

    Samir, Ahmed; Elgamal, Basma M; Gabr, Hala; Sabaawy, Hatem E

    2015-09-01

    A major limitation to current cancer therapies is the development of therapy-related side-effects and dose limiting complications. Moreover, a better understanding of the biology of cancer cells and the mechanisms of resistance to therapy is rapidly developing. The translation of advanced knowledge and discoveries achieved at the molecular level must be supported by advanced diagnostic, therapeutic and delivery technologies to translate these discoveries into useful tools that are essential in achieving progress in the war against cancer. Nanotechnology can play an essential role in this aspect providing a transforming technology that can translate the basic and clinical findings into novel diagnostic, therapeutic and preventive tools useful in different types of cancer. Hematological malignancies represent a specific class of cancer, which attracts special attention in the applications of nanotechnology for cancer diagnosis and treatment. The aim of the present review is to elucidate the emerging applications of nanotechnology in cancer management and describe the potentials of nanotechnology in changing the key fundamental aspects of hematological malignancy diagnosis, treatment and follow-up.

  19. Hematology journals do not sufficiently adhere to reporting guidelines: a systematic review.

    Science.gov (United States)

    Wayant, C; Smith, C; Sims, M; Vassar, M

    2017-04-01

    Essentials Reporting guidelines and trial/review registration aim to limit bias in research. We systematically reviewed hematology journals to examine the use of these policies. Forty-eight percent of journals made no use of these policies. Improving the use of reporting guidelines will improve research for all stakeholders. Background Reporting guidelines and trial/review registration policies have been instituted in order to minimize bias and improve research practices. Objective The objective of this study was to investigate the policies of hematology journals concerning reporting guideline adoption and trial/review registration. Methods We performed a web-based data abstraction from the Instructions for Authors of 67 hematology journals catalogued in the Expanded Science Citation Index of the 2014 Journal Citation Reports to identify whether each journal required, recommended or made no mention of the following reporting guidelines: EQUATOR, ICMJE, CONSORT, MOOSE, QUOROM, PRISMA, STARD, STROBE, ARRIVE and CARE. We also extracted whether journals required or recommended trial or systematic review registration. We e-mailed editors three times to determine which types of studies their journal accepts. Results Forty-eight per cent (32/67) of hematology journals do not adhere to any reporting guidelines. For responding journals, the QUOROM statement, MOOSE, CARE and PROSPERO were the least often mentioned, whereas the ICMJE guidelines, CONSORT statement and general trial registration were most often mentioned. Discussion Reporting guidelines are infrequently required or recommended by hematology journals. Furthermore, few require clinical trial or systematic review database registration. A higher rate of adherence to reporting guidelines can prevent bias from entering the literature. Participation from all stakeholders, including authors and journal editors, to improve reporting guideline and policy practices is required. © 2017 International Society on Thrombosis

  20. α-Lipoic Acid Mitigates Arsenic-Induced Hematological Abnormalities in Adult Male Rats

    Directory of Open Access Journals (Sweden)

    Sonali Ghosh

    2017-05-01

    Full Text Available Background: Arsenic toxicity is a major global health problem and exposure via contaminated drinking water has been associated with hematological and other systemic disorders. The present investigation has been conducted in adult male rats to evaluate the protective ability of α-lipoic acid (ALA against such hematological disorders. Methods: Twenty-four adult male Wister rats (b.wt.130±10g were grouped and accordingly group I (control received the normal diet, group II (treated was given arsenic orally for 28 consecutive days as arsenic trioxide (3 mg/kgbw/rat/day whereas group III (supplemented received the same dose of arsenic along with ALA (25 mg/kgbw/rat/day as oral supplement. Hematological profile, plasma oxidant/antioxidant status, and erythrocyte morphology were assessed. Statistical analysis was done by one-way ANOVA using SPSS software (version 16.0. Results: Arsenic exposure caused reduction of erythrocyte (P=0.021, leucocyte (P<0.001, and hemoglobin (P=0.031 associated with echinocytic transformation as evidenced by light and scanning electron microscopic studies. The other significantly altered parameters include increased mean corpuscular volume (P=0.041 and lymphocytopenia (P<0.001 with insignificant neutropenia and eosinophilia. Altered serum oxidative balance as evidenced by decreased TAS (P<0.001 and increased TOS (P<0.001 with OSI (P<0.001 was also noted. The dietary supplementation of ALA has a beneficial effect against the observed (P<0.05 arsenic toxicities. It brings about the protection by restoring the hematological redox and inflammatory status near normal in treated rats. Arsenic-induced morphological alteration of erythrocytes was also partially attenuated by ALA supplementation. Conclusion: It is concluded that arsenicosis is associated with hematological alterations and ALA co-supplementation can partially alleviate these changes in an experimental male rat model.

  1. Development of laser diode-pumped high average power solid-state laser for the pumping of Ti:sapphire CPA system

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Yoichiro; Tei, Kazuyoku; Kato, Masaaki; Niwa, Yoshito; Harayama, Sayaka; Oba, Masaki; Matoba, Tohru; Arisawa, Takashi; Takuma, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-03-01

    Laser diode pumped all solid state, high repetition frequency (PRF) and high energy Nd:YAG laser using zigzag slab crystals has been developed for the pumping source of Ti:sapphire CPA system. The pumping laser installs two main amplifiers which compose ring type amplifier configuration. The maximum amplification gain of the amplifier system is 140 and the condition of saturated amplification is achieved with this high gain. The average power of fundamental laser radiation is 250 W at the PRF of 200 Hz and the pulse duration is around 20 ns. The average power of second harmonic is 105 W at the PRF of 170 Hz and the pulse duration is about 16 ns. The beam profile of the second harmonic is near top hat and will be suitable for the pumping of Ti:sapphire laser crystal. The wall plug efficiency of the laser is 2.0 %. (author)

  2. Influence of different aspect ratios on the structural and electrical properties of GaN thin films grown on nanoscale-patterned sapphire substrates

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Fang-Wei [Department of Electrophysics, National Chiao-Tung University, Hsinchu 300, Taiwan (China); Ke, Wen-Cheng, E-mail: wcke@mail.ntust.edu.tw [Department of Materials Science and Engineering, National Taiwan University of Science and Technology, Taipei 106, Taiwan (China); Cheng, Chun-Hong; Liao, Bo-Wei; Chen, Wei-Kuo [Department of Electrophysics, National Chiao-Tung University, Hsinchu 300, Taiwan (China)

    2016-07-01

    Highlights: • Nanoscale patterned sapphire substrate was prepared by anodic-aluminum-oxide etching mask. • Influence of aspect ratio of NPSS on structural and electrical properties of GaN films was studied. • Low dislocation density and high carrier mobility of GaN films were grown on high aspect ratio NPSS. - Abstract: This study presents GaN thin films grown on nanoscale-patterned sapphire substrates (NPSSs) with different aspect ratios (ARs) using a homemade metal-organic chemical vapor deposition system. The anodic aluminum oxide (AAO) technique is used to prepare the dry etching mask. The cross-sectional view of the scanning electron microscope image shows that voids exist between the interface of the GaN thin film and the high-AR (i.e. ∼2) NPSS. In contrast, patterns on the low-AR (∼0.7) NPSS are filled full of GaN. The formation of voids on the high-AR NPSS is believed to be due to the enhancement of the lateral growth in the initial growth stage, and the quick-merging GaN thin film blocks the precursors from continuing to supply the bottom of the pattern. The atomic force microscopy images of GaN on bare sapphire show a layer-by-layer surface morphology, which becomes a step-flow surface morphology for GaN on a high-AR NPSS. The edge-type threading dislocation density can be reduced from 7.1 × 10{sup 8} cm{sup −2} for GaN on bare sapphire to 4.9 × 10{sup 8} cm{sup −2} for GaN on a high-AR NPSS. In addition, the carrier mobility increases from 85 cm{sup 2}/Vs for GaN on bare sapphire to 199 cm{sup 2}/Vs for GaN on a high-AR NPSS. However, the increased screw-type threading dislocation density for GaN on a low-AR NPSS is due to the competition of lateral growth on the flat-top patterns and vertical growth on the bottom of the patterns that causes the material quality of the GaN thin film to degenerate. Thus, the experimental results indicate that the AR of the particular patterning of a NPSS plays a crucial role in achieving GaN thin film with

  3. Broadband dielectric characterization of sapphire/TiOx/Ba₀.₃Sr₀.₇TiO₃ (111)-oriented thin films for the realization of a tunable interdigitated capacitor.

    Science.gov (United States)

    Ghalem, Areski; Ponchel, Freddy; Remiens, Denis; Legier, Jean-Francois; Lasri, Tuami

    2013-05-01

    A complete microwave characterization up to 67 GHz using specific coplanar waveguides was performed to determine the dielectric properties (permittivity, losses, and tunability) of sapphire/TiOx/Ba0.3Sr0.7TiO3 (BST) (111)-oriented thin films. To that end, BaxSr1-xTiO3 thin films were deposited by RF magnetron sputtering on sapphire (0001) substrate. To control the preferred (111) orientation, a TiOx buffer layer was deposited on sapphire. According to the detailed knowledge of the material properties, it has been possible to conceive, fabricate, and test interdigitated capacitors, the basic element for future microwave tunable applications. Retention of capacitive behavior up to 67 GHz and a tunability of 32% at 67 GHz at an applied voltage of 30 V (150 kV/cm) were observed. The Q-factor remains greater than 30 over the entire frequency band. The possibility of a complete characterization of the material for the realization of high-performance interdigitated capacitors opens the door to microwave device fabrication.

  4. EVALUATION OF ZEBU NELLORE CATTLE BLOOD SAMPLES USING THE CELL-DYN 3500 HEMATOLOGY ANALYZER

    Directory of Open Access Journals (Sweden)

    Alexandre Secorun Borges

    2014-12-01

    Full Text Available The Cell-dyn 3500 is a multiparameter flow cytometer, which may analyze samples from several species performing several simultaneous analyses. It is able to perform white blood cells, red blood cells and platelet counts, besides differential leukocyte counts, packed cell volume and hemoglobin determination. Cell-Dyn 3500 performs total leukocyte count both optically and by impedance. The equipment may choose one or other method, based on the reliability of the results. Erythrocyte and platelet counts are determined by impedance. Leukocyte differentiation is based on an optical principle, using separation in multiangular polarized light. The objective of this study was to compare the results of complete blood count of Zebu Nellore heifers from Celldyn 3500, with those obtained from a semi-automated cell counter (Celm CC 510 and the manual technique. Blood samples were collected from the jugular vein in 5 mL EDTA vacuum tubes from 58 Nellore heifers, at 24 months of age. Samples were processed in parallel in the three different techniques. Results were analyzed using paired t test, Pearson’s correlation and the Bland-Altmann method. There was a strong correlation for all parameters analyzed by Cell-Dyn 3500, manual method and semiautomated cell counter, except for basophils and monocytes counts. These results confirm that this analyzer is reliable for blood samples analysis of zebu cattle.

  5. Molecular beam epitaxy of InN layers on Sapphire, GaN and indium tin oxide

    Energy Technology Data Exchange (ETDEWEB)

    Denker, Christian; Landgraf, Boris; Schuhmann, Henning; Malindretos, Joerg; Seibt, Michael; Rizzi, Angela [IV. Physikalisches Institut, Georg-August-Universitaet Goettingen (Germany); Segura-Ruiz, Jaime; Gomez-Gomez, Maribel; Cantarero, Andres [Materials Science Institute, University of Valencia, Paterna (Spain)

    2009-07-01

    Among the group-III nitrides semiconductors, InN is the one with the narrowest gap (0.67 eV), lowest effective electron mass and highest peak drift velocity. It is therefore a very interesting material for several applications, in particular semiconductor solar cells. Furthermore, the high electron affinity makes it suitable also as electrode material for organic solar cells. InN layers were grown by molecular beam epitaxy on MOCVD GaN templates, on bare c-plane sapphire and on polycrystalline indium tin oxide. On all substrates the III-V ratio as well as the substrate temperature was varied. A RHEED analysis of InN growth on GaN showed a relatively sharp transition from N-rich and columnar growth to In-rich growth with droplet formation by increasing the In flux impinging on the surface. The InN layers on single crystalline substrates were characterized by SEM, AFM, XRD, PL and Raman. The InN layers on ITO were mainly analyzed with respect to the surface morphology with SEM. HRTEM in cross section gives insight into the structure of the interface to the ITO substrate.

  6. Morphological Evolution of a-GaN on r-Sapphire by Metalorganic Chemical Vapor Deposition

    International Nuclear Information System (INIS)

    Sang Ling; Liu Jian-Ming; Xu Xiao-Qing; Wang Jun; Zhao Gui-Juan; Liu Chang-Bo; Gu Cheng-Yan; Liu Gui-Peng; Wei Hong-Yuan; Liu Xiang-Lin; Yang Shao-Yan; Zhu Qin-Sheng; Wang Zhan-Guo

    2012-01-01

    The morphological evolution of a-GaN deposited by metalorganic chemical vapor deposition (MOCVD) on r-sapphire is studied. The influences of V/III ratio and growth temperature on surface morphology are investigated. V-pits and stripes are observed on the surface of a-GaN grown at 1050°C and 1100°C, respectively. The overall orientation and geometry of V-pits are uniform and independent on the V/III molar ratio in the samples grown at 1050°C, while in the samples grown at 1100°C, the areas of stripes decrease with the adding of V/III ratio. We deduce the origin of V-pits and stripes by annealing the buffer layers at different temperatures. Because of the existence of inclined (101-bar1) facets, V-pits are formed at 1050°C. The (101-bar1) plane is an N terminated surface, which is metastable at higher temperature, so stripes instead of V-pits are observed at 1100°C. Raman spectra suggest that the growth temperature of the first layer in the two-step process greatly affects the strain of the films. Hence, to improve the growth temperature of the first layer in the two-step method may be an effective way to obtain high quality a-GaN film on r-sapphire. (condensed matter: structure, mechanical and thermal properties)

  7. N-polar InGaN-based LEDs fabricated on sapphire via pulsed sputtering

    OpenAIRE

    Kohei Ueno; Eiji Kishikawa; Jitsuo Ohta; Hiroshi Fujioka

    2017-01-01

    High-quality N-polar GaN epitaxial films with an atomically flat surface were grown on sapphire (0001) via pulsed sputtering deposition, and their structural and electrical properties were investigated. The crystalline quality of N-polar GaN improves with increasing film thickness and the full width at half maximum values of the x-ray rocking curves for 0002 and 101¯2 diffraction were 313 and 394 arcsec, respectively, at the film thickness of 6μm. Repeatable p-type doping in N-polar GaN films...

  8. Incidence and risk of hematologic toxicities in cancer patients treated with regorafenib.

    Science.gov (United States)

    Zhao, Bin; Zhao, Hong

    2017-11-07

    Regorafenib, an oral vascular endothelial growth factor receptor tyrosine-kinase inhibitor, has been approved for the treatment of several malignancies. As a non-traditional cytotoxic chemotherapeutic agent, regorafenib is often associated with hematologic toxicities. Here we searched PubMed and Embase up to June 2017 for relevant clinical trials. Eligible studies include trials in which subjects treated with 160 mg of regorafenib daily during the first 21 days of each 28-day cycle, and adequate safety data profile reporting thrombocytopenia, anemia, neutropenia and leucopenia. Statistical analyses were conducted to calculate the overall incidences, relative risks (RRs) and their 95% confidence intervals (CIs). A total of 2,341 subjects from 16 trials were included in the present studies. The incidences of regorafenib associated all-grade and high-grade hematologic toxicities were: thrombocytopenia, 22% and 3%; anemia, 20% and 3%; neutropenia, 10% and 2%, and leucopenia, 13% and 2%, respectively. Regorafenib-treated subjects had a significant increased risk of all-grade (RR=6.35; 95% CI, 3.19-12.64) and high-grade (RR=6.27; 95% CI, 1.69-23.26) thrombocytopenia, all-grade (RR=2.76; 95% CI, 1.63-4.68) and high-grade (RR=5.38; 95% CI, 1.60-18.06) anemia. Our results suggested that regorafenib therapy was associated with significantly increased risks of hematological toxicities, and hematologic monitoring at regular intervals should be advised to clinician.

  9. [Distribution of Pathogenic Bacteria and Its Influence on Expression of BCL-2 and BAX Protein after HSCT in the Patients with Hematological Malignancies].

    Science.gov (United States)

    Su, Gui-Ping; Dai, Yan; Huang, Lai-Quan; Jiang, Yi-Zhi; Geng, Liang-Quan; Ding, Kai-Yang; Huang, Dong-Ping

    2016-06-01

    To investigate the distribution of pathogenic bacteria in the patients with hematologic malignancies received hematopoietic stem cell transplantation (HSCT) and its influence on the expression of BCL-2 and BAX proteins. The clinical data of 64 patients with malignant lymphoma (ML) received auto-HSCT from January 2011 to December 2015 in our hospital were analyzed. On basis of post-treansplant infection, the patients were divided into infection group (36 cases) and non-infection group (28 cases). The distribution of pathogenic bacteria in 2 groups was identified, the T lymphocyte subsets of peripheral blood, expression level of apoptotic proteins and C-reaction protein (CRP) in 2 group were detected. Thirty-six strains of pathogenic bacteria were isolated from 36 case of hematological malignancy after HSCT, including 24 strains of Gram-negative bacteria (66.67%) with predominamce of klebsiella pneumoniae (19.44%). The periperal blood CD4+ (t=2.637, Ppathogenic bacteria infecting ML patients after HSCT were mainly Gram-negative bacteria. The post-transplant infection can promote the expression up-regulation of related inflammatory factors and apoptotic proteins. The pathogens may be involved in cell apoptisis that provides a new strategy to treat the hematologic malignancies.

  10. Hematologic changes in dogs naturally infected Leptospira spp., Brucella abortus and Brucella canis

    Directory of Open Access Journals (Sweden)

    Jacqueline Ribeiro de Castro

    2014-01-01

    Full Text Available ABSTRACT. Castro J.R., Silva C.B., Souza M.A., Salaberry S.R.S., Guimarães E.C., Mundim A.V. & Lima-Ribeiro A.M.C. [Hematologic changes in dogs naturally infected Leptospira spp., Brucella abortus and Brucella canis.] Altera- ções hematológicas em cães naturalmente infectados por Leptospira spp., Brucella abortus e Brucella canis. Revista Brasileira de Medicina Veterinária, 36(1:49-54, 2014. Laboratório de Doenças Infectocontagiosas, Faculdade de Medicina Veterinária, Universidade Federal de Uberlândia, Av. Ceará s/n, Bloco 2D, Sala 33, Campus Umuarama, Uberlândia, MG 38400-902, Brasil. E-mail: jack_ufu@yahoo.com.br The investigations of leptospirosis and brucellosis canine act as sanitary control in public health and zoonoses because they were established by close contact between dog and human. The aim was to determine the main hematological reagents in asymptomatic dogs against Leptospira spp. Brucella abortus and Brucella canis naturally infected, living in urban areas in the city of Uberlandia, Minas Gerais. We examined 140 blood samples from clinically healthy dogs, males and females and different ages. Leptospirosis was diagnosed by microscopic agglutination test (MAT, with a collection of twelve serovars, whereas, brucellosis was identified through the tests of Agar Gel Immunodiffusion (AGID for B. canis and buffered acidified antigen (TAA confirmed 2-Mercaptoethanol (2-ME for B. abortus. The results were analyzed using descriptive statistics with the calculation of simple percentages, mean and standard deviation. He applied and short sample t test for two independent samples to assess whether there were significant differences (p<0.05 between hematological parameters obtained. Dogs evaluated, 15% (21/140 and 2.85% (4/140 were reactive to Leptospira spp. and B. abortus, respectively. There was no sample reagent against B. canis. It was concluded that although no specific thrombocytopenia may be a significant finding in dogs

  11. Development of the family symptom inventory: a psychosocial screener for children with hematology/oncology conditions.

    Science.gov (United States)

    Karlson, Cynthia W; Haynes, Stacey; Faith, Melissa A; Elkin, Thomas D; Smith, Maria L; Megason, Gail

    2015-03-01

    A growing body of literature has begun to underscore the importance of integrating family-based comprehensive psychological screening into standard medical care for children with oncology and hematology conditions. There are no known family-based measures designed to screen for clinically significant emotional and behavioral concerns in pediatric oncology and hematology patients. The aim of this study was to develop and evaluate the Family Symptom Inventory (FSI), a brief screener of patient and family member psychological symptoms. The FSI also screens for common comorbid physical symptoms (pain and sleep disturbance) and is designed for use at any point during treatment and follow-up. A total of 488 caregivers completed the FSI during regular hematology/oncology visits for 193 cancer, 219 sickle cell disease, and 76 hematology pediatric patients. Exploratory factor analysis, confirmatory factor analysis, and tests of reliability and preliminary validity were conducted. Exploratory factor analysis suggested a 34-item, 4-factor solution, which was confirmed in an independent sample using confirmatory factor analysis (factor loadings=0.49 to 0.88). The FSI demonstrated good internal reliability (α's=0.86 to 0.92) and good preliminary validity. Regular psychosocial screening throughout the course of treatment and follow-up may lead to improved quality of care for children with oncology and hematology conditions.

  12. Co-circulating serotypes in a dengue fever outbreak: Differential hematological profiles and phylogenetic relationships among viruses.

    Science.gov (United States)

    Carmo, Andreia Moreira Dos Santos; Suzuki, Rodrigo Buzinaro; Cabral, Aline Diniz; Costa, Renata Torres da; Massari, Gabriela Pena; Riquena, Michele Marcondes; Fracasso, Helio Augusto Alves; Eterovic, Andre; Marcili, Arlei; Sperança, Márcia Aparecida

    2017-05-01

    Dengue virus, represented by four distinct, genetically diverse serotypes, is the etiologic agent of asymptomatic to severe hemorrhagic diseases. The spatiotemporal dynamics of dengue serotypes and its association to specific diseases vary among the different regions worldwide. By 2007, and in São Paulo State, Brazil, dengue-case concentration in urban centers had changed to increased incidence in small- and medium-sized towns, the case of Marília. The aim of this article was to distinguish dengue serotypes circulating during the 2007 Marília outbreak and define their association to demographic and hematological patient profiles, as well as the phylogenetic relationships among the different viruses. PCR amplicons corresponding to the junction of capsid and dengue pre-membrane encoding genes, obtained from dengue serologically positive patients, were sequenced. Hematological and demographic data of patients with different Dengue serotypes were evaluated by univariate and bivariate statistics. Dengue PCR sequences were used in phylogenetic relationships analyzed for maximum parsimony. Molecular typing confirmed co-circulation of the dengue serotypes 1 (DENV1) and 3 (DENV3), which presented divergent correlation patterns with regard to hematological descriptors. The increase in atypical lymphocytes, a likely indication of virus load, could be significantly associated to a decrease in leukocyte counts in the DENV3 group and platelet in the DENV1. Phylogenetic reconstitution revealed the introduction of DENV1 from northern Brazil and local divergence of DENV3 by either microevolution or viral introduction from other geographical regions or both. Dengue dynamics showed regional molecular-epidemiologic specificity, which has important implications for introduction of vaccines, disease management, and transmission control. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Light refraction in sapphire plates with a variable angle of crystal optical axis to the surface

    International Nuclear Information System (INIS)

    Vetrov, V. N.; Ignatenkov, B. A.

    2013-01-01

    The modification of sapphire by inhomogeneous plastic deformation makes it possible to obtain plates with a variable angle of inclination of the crystal optical axis to the plate surface. The refraction of light in this plate at perpendicular and oblique incidence of a parallel beam of rays is considered. The algorithm of calculating the refractive index of extraordinary ray and the birefringence is proposed.

  14. Comprehensive reference ranges for hematology and clinical chemistry laboratory parameters derived from normal Nigerian adults.

    Directory of Open Access Journals (Sweden)

    Timzing Miri-Dashe

    Full Text Available Interpretation of laboratory test results with appropriate diagnostic accuracy requires reference or cutoff values. This study is a comprehensive determination of reference values for hematology and clinical chemistry in apparently healthy voluntary non-remunerated blood donors and pregnant women.Consented clients were clinically screened and counseled before testing for HIV, Hepatitis B, Hepatitis C and Syphilis. Standard national blood donors' questionnaire was administered to consented blood donors. Blood from qualified volunteers was used for measurement of complete hematology and chemistry parameters. Blood samples were analyzed from a total of 383 participants, 124 (32.4% males, 125 (32.6% non-pregnant females and 134 pregnant females (35.2% with a mean age of 31 years. Our results showed that the red blood cells count (RBC, Hemoglobin (HB and Hematocrit (HCT had significant gender difference (p = 0.000 but not for total white blood count (p>0.05 which was only significantly higher in pregnant verses non-pregnant women (p = 0.000. Hemoglobin and Hematocrit values were lower in pregnancy (P = 0.000. Platelets were significantly higher in females than men (p = 0.001 but lower in pregnant women (p =  .001 with marked difference in gestational period. For clinical chemistry parameters, there was no significant difference for sodium, potassium and chloride (p>0.05 but gender difference exists for Bicarbonate (HCO3, Urea nitrogen, Creatinine as well as the lipids (p0.05.Hematological and Clinical Chemistry reference ranges established in this study showed significant gender differences. Pregnant women also differed from non-pregnant females and during pregnancy. This is the first of such comprehensive study to establish reference values among adult Nigerians and difference observed underscore the need to establish reference values for different populations.

  15. Comprehensive reference ranges for hematology and clinical chemistry laboratory parameters derived from normal Nigerian adults.

    Science.gov (United States)

    Miri-Dashe, Timzing; Osawe, Sophia; Tokdung, Monday; Daniel, Monday Tokdung Nenbammun; Daniel, Nenbammun; Choji, Rahila Pam; Mamman, Ille; Deme, Kurt; Damulak, Dapus; Abimiku, Alash'le

    2014-01-01

    Interpretation of laboratory test results with appropriate diagnostic accuracy requires reference or cutoff values. This study is a comprehensive determination of reference values for hematology and clinical chemistry in apparently healthy voluntary non-remunerated blood donors and pregnant women. Consented clients were clinically screened and counseled before testing for HIV, Hepatitis B, Hepatitis C and Syphilis. Standard national blood donors' questionnaire was administered to consented blood donors. Blood from qualified volunteers was used for measurement of complete hematology and chemistry parameters. Blood samples were analyzed from a total of 383 participants, 124 (32.4%) males, 125 (32.6%) non-pregnant females and 134 pregnant females (35.2%) with a mean age of 31 years. Our results showed that the red blood cells count (RBC), Hemoglobin (HB) and Hematocrit (HCT) had significant gender difference (p = 0.000) but not for total white blood count (p>0.05) which was only significantly higher in pregnant verses non-pregnant women (p = 0.000). Hemoglobin and Hematocrit values were lower in pregnancy (P = 0.000). Platelets were significantly higher in females than men (p = 0.001) but lower in pregnant women (p =  .001) with marked difference in gestational period. For clinical chemistry parameters, there was no significant difference for sodium, potassium and chloride (p>0.05) but gender difference exists for Bicarbonate (HCO3), Urea nitrogen, Creatinine as well as the lipids (pchemistry parameters between pregnant and non-pregnant women in this study (p0.05). Hematological and Clinical Chemistry reference ranges established in this study showed significant gender differences. Pregnant women also differed from non-pregnant females and during pregnancy. This is the first of such comprehensive study to establish reference values among adult Nigerians and difference observed underscore the need to establish reference values for different populations.

  16. Planning for the future workforce in hematology research

    Science.gov (United States)

    Abkowitz, Janis L.; Coller, Barry S.; DiMichele, Donna M.

    2015-01-01

    The medical research and training enterprise in the United States is complex in both its scope and implementation. Accordingly, adaptations to the associated workforce needs present particular challenges. This is particularly true for maintaining or expanding national needs for physician-scientists where training resource requirements and competitive transitional milestones are substantial. For the individual, these phenomena can produce financial burden, prolong the career trajectory, and significantly influence career pathways. Hence, when national data suggest that future medical research needs in a scientific area may be met in a less than optimal manner, strategies to expand research and training capacity must follow. This article defines such an exigency for research and training in nonneoplastic hematology and presents potential strategies for addressing these critical workforce needs. The considerations presented herein reflect a summary of the discussions presented at 2 workshops cosponsored by the National Heart, Lung, and Blood Institute and the American Society of Hematology. PMID:25758827

  17. Percutaneous Nephrolithotomy for Kidney Stones in Patients with Hematological Malignancy

    Directory of Open Access Journals (Sweden)

    Baris Kuzgunbay

    2016-07-01

    Full Text Available Aim: To define the alterations in the outcomes of percutaneous nephrolithotomy (PNL operations for kidney stones in patients with history of hematological malignancy (HM. Material and Method: Between 2000 and 2013, 1700 adult patients underwent PNL for the treatment of kidney stones in our institution. Four of these patients had a history of HM and considered to be HM group (n=4. Ten elderly (>65 years patients who had no history of operation, HM or any other co-morbide diseases were chosen as the control group (n=10. Surgical parameters, success rates, additional treatments and complications were evaluated. Results: Statistical analyses showed no significant differences between HM and control group according to stone area, operation time, fluoroscopy time, hospitalization time, %u2206Hb, blood transfusion rates and INR values (p>0.05. Statistical analyses revealed no significant differences between HM and control groups according to the success rates (p=0.470. Statistical analyses revealed no significant difference between groups for additional treatment requirements (p=0.882. No major perioperative complication was seen in both of the groups. Discussion: The treatment of kidney stone disease by PNL in patients with hematological malignancy is feasible, safe and effective. However, close cooperation with the Hematology Department before the operation is mandatory.

  18. Proceedings from the 1st Insights in Hematology Symposium, Cluj-Napoca, Romania March 11-12, 2016.

    Science.gov (United States)

    Bojan, Anca; Berindan-Neagoe, Ioana; Ciurea, S; Dima, Delia; Fuji, Shigeo; Ghiaur, G; Grewal, Ravnit; Mccormack, Emmet; Tanase, Alina; Trifa, A; Tomuleasa, Ciprian

    2016-09-01

    In the March 2016 issue of the Lancet Haematology, the editorial office published a paper stating the roadmap for European research in hematology, based on the European Hematology Association (EHA) consensus document that outlines the directions in hematology for the following years across the continent. The meeting entitled "Insights in hematology" is organized a support for the initiative of a roadmap for European hematologists regarding research, may it be basic research or clinical research, but this consensus should not be focused mainly on European institutions, but rather form the backbone of global research between Europe and the United States, Japan or any other country. This will allow Europeans to learn as well as to share their experience with the rest of the scientific and medical community. And the Cluj-Napoca meeting should be followed by other such meetings all across the EU.

  19. Residential radon exposure and risk of incident hematologic malignancies in the Cancer Prevention Study-II Nutrition Cohort

    Energy Technology Data Exchange (ETDEWEB)

    Teras, Lauren R., E-mail: lauren.teras@cancer.org [Epidemiology Research Program, American Cancer Society, Atlanta, GA (United States); Diver, W. Ryan [Epidemiology Research Program, American Cancer Society, Atlanta, GA (United States); Turner, Michelle C. [Centre for Research in Environmental Epidemiology (CREAL), Barcelona (Spain); Universitat Pompeu Fabra (UPF), Barcelona (Spain); CIBER Epidemiología y Salud Pública (CIBERESP), Madrid (Spain); McLaughlin Centre for Population Health Risk Assessment, University of Ottawa, Ottawa (Canada); Krewski, Daniel [McLaughlin Centre for Population Health Risk Assessment, University of Ottawa, Ottawa (Canada); School of Epidemiology, Public Health and Disease Prevention, University of Ottawa, Ottawa, Ontario (Canada); Sahar, Liora [Statistics and Evaluation Center, American Cancer Society, Atlanta, GA (United States); Ward, Elizabeth [Intramural Research, American Cancer Society, Atlanta, GA (United States); Gapstur, Susan M. [Epidemiology Research Program, American Cancer Society, Atlanta, GA (United States)

    2016-07-15

    Dosimetric models show that radon, an established cause of lung cancer, delivers a non-negligible dose of alpha radiation to the bone marrow, as well as to lymphocytes in the tracheobronchial epithelium, and therefore could be related to risk of hematologic cancers. Studies of radon and hematologic cancer risk, however, have produced inconsistent results. To date there is no published prospective, population-based study of residential radon exposure and hematologic malignancy incidence. We used data from the American Cancer Society Cancer Prevention Study-II Nutrition Cohort established in 1992, to examine the association between county-level residential radon exposure and risk of hematologic cancer. The analytic cohort included 140,652 participants (66,572 men, 74,080 women) among which 3019 incident hematologic cancer cases (1711 men, 1308 women) were identified during 19 years of follow-up. Cox proportional hazard regression was used to calculate multivariable-adjusted hazard ratios (HRs) and corresponding 95% confidence intervals (CIs) for radon exposure and hematologic cancer risk. Women living in counties with the highest mean radon concentrations (>148 Bq/m{sup 3}) had a statistically significant higher risk of hematologic cancer compared to those living in counties with the lowest (<74 Bq/m{sup 3}) radon levels (HR=1.63, 95% CI:1.23–2.18), and there was evidence of a dose-response relationship (HR{sub continuous}=1.38, 95% CI:1.15–1.65 per 100 Bq/m{sup 3}; p-trend=0.001). There was no association between county-level radon and hematologic cancer risk among men. The findings of this large, prospective study suggest residential radon may be a risk factor for lymphoid malignancies among women. Further study is needed to confirm these findings. - Highlights: • This is the first prospective, general population study of residential radon and risk of hematologic cancer. • Findings from this study suggest that residential radon exposure may be a risk factor

  20. Residential radon exposure and risk of incident hematologic malignancies in the Cancer Prevention Study-II Nutrition Cohort

    International Nuclear Information System (INIS)

    Teras, Lauren R.; Diver, W. Ryan; Turner, Michelle C.; Krewski, Daniel; Sahar, Liora; Ward, Elizabeth; Gapstur, Susan M.

    2016-01-01

    Dosimetric models show that radon, an established cause of lung cancer, delivers a non-negligible dose of alpha radiation to the bone marrow, as well as to lymphocytes in the tracheobronchial epithelium, and therefore could be related to risk of hematologic cancers. Studies of radon and hematologic cancer risk, however, have produced inconsistent results. To date there is no published prospective, population-based study of residential radon exposure and hematologic malignancy incidence. We used data from the American Cancer Society Cancer Prevention Study-II Nutrition Cohort established in 1992, to examine the association between county-level residential radon exposure and risk of hematologic cancer. The analytic cohort included 140,652 participants (66,572 men, 74,080 women) among which 3019 incident hematologic cancer cases (1711 men, 1308 women) were identified during 19 years of follow-up. Cox proportional hazard regression was used to calculate multivariable-adjusted hazard ratios (HRs) and corresponding 95% confidence intervals (CIs) for radon exposure and hematologic cancer risk. Women living in counties with the highest mean radon concentrations (>148 Bq/m 3 ) had a statistically significant higher risk of hematologic cancer compared to those living in counties with the lowest (<74 Bq/m 3 ) radon levels (HR=1.63, 95% CI:1.23–2.18), and there was evidence of a dose-response relationship (HR continuous =1.38, 95% CI:1.15–1.65 per 100 Bq/m 3 ; p-trend=0.001). There was no association between county-level radon and hematologic cancer risk among men. The findings of this large, prospective study suggest residential radon may be a risk factor for lymphoid malignancies among women. Further study is needed to confirm these findings. - Highlights: • This is the first prospective, general population study of residential radon and risk of hematologic cancer. • Findings from this study suggest that residential radon exposure may be a risk factor for lymphoid

  1. Hematological values in juvienile periodontitis patients in Ibadan ...

    African Journals Online (AJOL)

    In this study, clinical and hematological examinations of forty adolescent patients in the group (15-22) years with established clinical features of chronic periodontitis but without any diagnosable medical disease were done. The patients were divided into two Groups (A &B). Group A were diagnosed as having juvenile ...

  2. Hematological derangement patterns in Nigerian dogs infected with ...

    African Journals Online (AJOL)

    Hematological derangement patterns in Nigerian dogs infected with Trypanosoma brucei : A simple prototype for assessing tolerance to trypanosome infections ... The packed cell volume (PCV), red blood cell (RBC) counts, total and differential white blood cell (WBC) counts and rates of both red blood cell and white blood ...

  3. Structural and electronic properties of InN epitaxial layer grown on c-plane sapphire by chemical vapor deposition technique

    Energy Technology Data Exchange (ETDEWEB)

    Barick, Barun Kumar, E-mail: bkbarick@gmail.com; Prasad, Nivedita; Saroj, Rajendra Kumar; Dhar, Subhabrata [Department of Physics, Indian Institute of Technology, Bombay, Mumbai 400076 (India)

    2016-09-15

    Growth of InN epilayers on c-plane sapphire substrate by chemical vapor deposition technique using pure indium metal and ammonia as precursors has been systematically explored. It has been found that [0001] oriented indium nitride epitaxial layers with smooth surface morphology can be grown on c-plane sapphire substrates by optimizing the growth conditions. Bandgap of the film is observed to be Burstein–Moss shifted likely to be due to high background electron concentration. It has been found that the concentration of this unintentional doping decreases with the increase in the growth temperature and the ammonia flux. Epitaxial quality on the other hand deteriorates as the growth temperature increases. Moreover, the morphology of the deposited layer has been found to change from flat top islands to faceted mounds as the flow rate of ammonia increases. This phenomenon is expected to be related to the difference in surface termination character at low and high ammonia flow rates.

  4. Self-assembled growth and structural analysis of inclined GaN nanorods on nanoimprinted m-sapphire using catalyst-free metal-organic chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyuseung; Chae, Sooryong; Jang, Jongjin; Min, Daehong; Kim, Jaehwan; Nam, Okhyun, E-mail: ohnam@kpu.ac.kr [Convergence Center for Advanced Nano Semiconductor (CANS), Department of Nano-Optical Engineering, Korea Polytechnic University, Siheung, 15073 (Korea, Republic of)

    2016-04-15

    In this study, self-assembled inclined (1-10-3)-oriented GaN nanorods (NRs) were grown on nanoimprinted (10-10) m-sapphire substrates using catalyst-free metal-organic chemical vapor deposition. According to X-ray phi-scans, the inclined GaN NRs were tilted at an angle of ∼57.5° to the [10-10]{sub sapp} direction. Specifically, the GaN NRs grew in a single inclined direction to the [11-20]{sub sapp}. Uni-directionally inclined NRs were formed through the one-sided (10-11)-faceted growth of the interfacial a-GaN plane layer. It was confirmed that a thin layer of a-GaN was formed on r-facet nanogrooves of the m-sapphire substrate by nitridation. The interfacial a-GaN nucleation affected both the inclined angle and the growth direction of the inclined GaN NRs. Using X-ray diffraction and selective area electron diffraction, the epitaxial relationship between the inclined (1-10-3) GaN NRs and interfacial a-GaN layer on m-sapphire substrates was systematically investigated. Moreover, the inclined GaN NRs were observed to be mostly free of stacking fault-related defects using high-resolution transmission electron microscopy.

  5. Viral findings in adult hematological patients with neutropenia.

    Directory of Open Access Journals (Sweden)

    Lars Ohrmalm

    Full Text Available BACKGROUND: Until recently, viral infections in patients with hematological malignancies were concerns primarily in allogeneic hematopoietic stem cell transplant (HSCT recipients. During the last years, changed treatment regimens for non-transplanted patients with hematological malignancies have had potential to increase the incidence of viral infections in this group. In this study, we have prospectively investigated the prevalence of a broad range of respiratory viruses in nasopharyngeal aspirate (NPA as well as viruses that commonly reactivate after allogeneic HSCT. METHODOLOGY/PRINCIPAL FINDINGS: Patients with hematological malignancies and therapy induced neutropenia (n = 159 were screened regarding a broad range of common respiratory viruses in the nasopharynx and for viruses commonly detected in severely immunosuppressed patients in peripheral blood. Quantitative PCR was used for detection of viruses. A viral pathogen was detected in 35% of the patients. The detection rate was rather similar in blood (22% and NPA (18% with polyoma BK virus and rhinovirus as dominating pathogens in blood and NPA, respectively. Patients with chronic lymphocytic leukemia (CLL (p<0.01 and patients with fever (p<0.001 were overrepresented in the virus-positive group. Furthermore, viral findings in NPA were associated with upper respiratory symptoms (URTS (p<0.0001. CONCLUSIONS/SIGNIFICANCE: Both respiratory viral infections and low titers of viruses in blood from patients with neutropenia were common. Patients with CLL and patients with fever were independently associated to these infections, and viral findings in NPA were associated to URTS indicating active infection. These findings motivate further studies on viruses' impact on this patient category and their potential role as causative agents of fever during neutropenia.

  6. Hematological abnormalities and 22q11.2 deletion syndrome

    Directory of Open Access Journals (Sweden)

    Rafael Fabiano Machado Rosa

    2011-01-01

    Full Text Available The 22q11.2 deletion syndrome (22q11DS is a common genetic disease characterized by broad phenotypic variability. Despite the small number of studies describing hematological alterations in individuals with 22q11DS, it appears that these abnormalities are more frequent than previously imagined. Thus, the objective of our study was to report on a patient with 22q11DS presenting thrombocytopenia and large platelets and to review the literature. The patient, a 13-year-old boy, was originally evaluated due to craniofacial dysmorphia and speech delay. He also had a history of behavioral changes, neuropsychomotor delay and recurrent otitis/sinusitis. The identification of a 22q11.2 microdeletion by fluorescent in situ hybridization diagnosed the syndrome. Despite his hematological alterations, he only had a history of epistaxis and bruising of the upper and lower limbs. Assessments of the prothrombin time, thrombin time, partial thromboplastin time, bleeding time, fibrinogen levels and platelet aggregation (including the ristocetin induced platelet aggregation test were all normal. Hematological alterations observed in 22q11DS are directly related to the genetic disorder itself (especially in respect to deletion of the GPIb gene and secondary to some clinical findings, such as immunodeficiency. Macrothrombocytopenia is increasingly being considered a feature of the broad spectrum of 22q11DS and may potentially be a clinical marker for the syndrome.

  7. Some hematological disorders among atomic bomb survivors. Presidential Address

    International Nuclear Information System (INIS)

    Watanabe, Susumu

    1977-01-01

    Focusing on their hematological disorders, the late radiation effects among Hiroshima and Nagasaki A-bomb survivors, including cytogenetic and cytological studies, are summarized and discussed. Because of personal research experience, the data were concentrated on the Hiroshima survivors

  8. Time-resolved photoemission micro-spectrometer using higher-order harmonics of Ti:sapphire laser

    International Nuclear Information System (INIS)

    Azuma, J.; Kamada, M.; Kondo, Y.

    2004-01-01

    Full text: A new photoemission spectrometer is under construction for the photoemission microscopy and the time-resolved pump- probe experiment. The higher order harmonics of the Ti:sapphire laser is used as the light source of the VUV region in this system. Because the fundamental laser is focused tightly into the rare gas jet to generate the higher order harmonics, the spot size of the laser, in other words, the spot size of the VUV light source is smaller than a few tens of micrometer. This smallness of the spot size has advantage for the microscopy. In order to compensate the low flux of the laser harmonics, a multilayer-coated schwaltzshild optics was designed. The multilayers play also as the monochromatic filter. The spatial resolution of this schwaltzshild system is found to be less than 1 micrometer by the ray-tracing calculations. A main chamber of the system is equipped with a time-of-flight energy analyzer to improve the efficiency of the electron detection. The main chamber and the gas chamber are separated by a differential pumping chamber and a thin Al foil. The system is designed for the study of the clean surface. It will be capable to perform the sub-micron photoemission microscopy and the femto-second pump-probe photoemission study for the various photo-excited dynamics on clean surfaces

  9. Synthesis of high quality graphene on capped (1 1 1) Cu thin films obtained by high temperature secondary grain growth on c-plane sapphire substrates

    Science.gov (United States)

    Kim, Youngwoo; Moyen, Eric; Yi, Hemian; Avila, José; Chen, Chaoyu; Asensio, Maria C.; Lee, Young Hee; Pribat, Didier

    2018-07-01

    We propose a novel growth technique, in which graphene is synthesized on capped Cu thin films deposited on c-plane sapphire. The cap is another sapphire plate which is just laid upon the Cu thin film, in direct contact with it. Thanks to this ‘contact cap’, Cu evaporation can be suppressed at high temperature and the 400 nm-thick Cu films can be annealed above 1000 °C, resulting in (1 1 1)-oriented grains of millimeter size. Following this high temperature annealing, graphene is grown by chemical vapor deposition during the same pump-down operation, without removing the contact cap. The orientation and doping type of the as-grown graphene were first studied, using low energy electron diffraction, as well as high resolution angle-resolved photoemission spectroscopy. In particular, the orientation relationships between the graphene and copper thin film with respect to the sapphire substrate were precisely determined. We find that the graphene sheets exhibit a minimal rotational disorder, with ~90% of the grains aligned along the copper high symmetry direction. Detailed transport measurements were also performed using field-effect transistor structures. Carrier mobility values as high as 8460 cm2 V‑1 s‑1 have been measured on top gate transistors fabricated directly on the sapphire substrate, by etching the Cu film from underneath the graphene sheets. This is by far the best carrier mobility value obtained to date for graphene sheets synthesized on a thin film-type metal substrate.

  10. Hematological observations on two cases of acute radiation syndrome

    International Nuclear Information System (INIS)

    Jiang Benrong; Wang Guilin; Huang Shimin

    1990-01-01

    The hematological changes of two cases of acute radiation syndrome were observed. The physical doses of patients Liang and Yan were 3.5 Gy and 2.6 Gy respectively. According to the changes in WBC and platelet counts and the absolute count of lymphocytes and in comparison with the hematological data of the victims of Y-12 accident in USA in 1958 and those of previous accidents in China, Liang suffered from a moderate or moderate to severe degree, and Yan suffered from a moderate or moderate mild degree of hemopoietic form of acute radiation syndrome. This estimation was consistent with their clinical course and physical doses. Some blood cells appeared in the cytoplasm of megakaryocytes in bone marrow smears of those two cases. The mechanism of this phenomenon is discussed and its clinical significance remains to be studied

  11. The effect of lead poisoning on hematologic and biochemical values in trumpeter swans and Canada geese.

    Science.gov (United States)

    Katavolos, P; Staempfli, S; Sears, W; Gancz, A Y; Smith, D A; Bienzle, D

    2007-12-01

    Lead is a persistent contaminant in the environment, and waterfowl are susceptible to lead toxicity from ingestion of lead pellets and fishing weights. Lead affects numerous physiologic processes through inhibition of enzyme activity and protein function, but its effects on commonly assessed avian blood values are incompletely understood. Our aim was to evaluate hematologic and biochemical changes associated with blood lead concentrations in trumpeter swans and Canada geese. Data for CBCs, plasma biochemical profiles (total protein, albumin, glucose, cholesterol, total bilirubin, calcium, phosphorus, gamma-glutamyltransferase [GGT], aspartate aminotransferase, lactate dehydrogenase, glutamate dehydrogenase, creatine kinase, amylase, and lipase), and whole blood lead concentrations were retrospectively analyzed for 69 trumpeter swans and 52 Canada geese. Laboratory data obtained prospectively from an additional 20 trumpeter swans also were included. RBC morphology was semiquantitated in blood smears from 70 of the birds. Data were analyzed initially by ANOVA and covariance. A statistical model then was constructed to determine the relationship between each parameter and lead concentration. In both avian species, PCV, hemoglobin concentration, and MCHC decreased significantly (P < .05) with increasing blood lead concentration. Uric acid concentration and GGT activity were increased in trumpeter swans and phosphorus concentration was decreased in Canada geese in association with high blood lead concentration (P < .05). Lead toxicosis induced significant changes in the values of commonly measured hematologic parameters in waterfowl. These changes may be useful indicators of severe lead intoxication during routine laboratory assessment. Changes in clinical chemistry values, although statistically significant, were too inconsistent to serve as indicators of lead toxicosis.

  12. Regulating hematology/oncology research involving human participants.

    Science.gov (United States)

    Kapp, Marshall B

    2002-12-01

    The conduct of hematology/oncology research, particularly clinical trials involving human participants, is an extensively regulated enterprise. Professionals in the specialty of hematology/oncology have important stakes in the success of biomedical research endeavors. Knowledge about and compliance strategies regarding the pertinent regulatory parameters are essential for avoiding negative legal repercussions for involved professionals. At the same time, there is a need to be aware of and actively resist the danger that strong [legal] protectionism might inadvertently result in undermining physician investigators' sense of personal moral responsibility in the conduct of human experiments. For all the limitations of that virtue in the protection of human subjects, it is surely not one that we would want medical scientists to be without [47]. Members of the potential participant pool, financial sponsors, and the general public must be convinced that everyone involved in the research enterprise is committed to operating within acceptable legal and ethical boundaries if the atmosphere of confidence and trust that is indispensable to the continued process and progress of investigation aimed at extending and improving quality of life for all of us in the future is to continue and flourish [48].

  13. High-quality nonpolar a-plane GaN epitaxial films grown on r-plane sapphire substrates by the combination of pulsed laser deposition and metal–organic chemical vapor deposition

    Science.gov (United States)

    Yang, Weijia; Zhang, Zichen; Wang, Wenliang; Zheng, Yulin; Wang, Haiyan; Li, Guoqiang

    2018-05-01

    High-quality a-plane GaN epitaxial films have been grown on r-plane sapphire substrates by the combination of pulsed laser deposition (PLD) and metal–organic chemical vapor deposition (MOCVD). PLD is employed to epitaxial growth of a-plane GaN templates on r-plane sapphire substrates, and then MOCVD is used. The nonpolar a-plane GaN epitaxial films with relatively small thickness (2.9 µm) show high quality, with the full-width at half-maximum values of GaN(11\\bar{2}0) along [1\\bar{1}00] direction and GaN(10\\bar{1}1) of 0.11 and 0.30°, and a root-mean-square surface roughness of 1.7 nm. This result is equivalent to the quality of the films grown by MOCVD with a thickness of 10 µm. This work provides a new and effective approach for achieving high-quality nonpolar a-plane GaN epitaxial films on r-plane sapphire substrates.

  14. Sapphire: a better material for atomization and in situ collection of silver volatile species for atomic absorption spectrometry

    Czech Academy of Sciences Publication Activity Database

    Musil, Stanislav; Matoušek, Tomáš; Dědina, Jiří

    2015-01-01

    Roč. 108, JUN (2015), s. 61-67 ISSN 0584-8547 R&D Projects: GA ČR GA14-23532S Grant - others:GA AV ČR(CZ) M200311202 Institutional support: RVO:68081715 Keywords : silver * volatile species generation * sapphire tube atomizer Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.289, year: 2015

  15. Prevalence of hematological abnormalities and malnutrition in HIV ...

    African Journals Online (AJOL)

    Their hemoglobin level, neutrophil, and platelet counts were the hematological profiles evaluated using the WHO case definitions in HIV clinical staging. The weight-for-height z-score index was used to assess the nutritional status of subjects using the WHO reference ranges. The t-test, Chi-square, and Pearson correlation ...

  16. Management of acute perianal sepsis in neutropenic patients with hematological malignancy.

    Science.gov (United States)

    Baker, B; Al-Salman, M; Daoud, F

    2014-04-01

    In neutropenic patients with acute perianal sepsis in the setting of hematological malignancy, the classical clinical features of abscess formation are lacking. Additionally, the role of surgical intervention is not well established. In this review, we discuss the challenges and controversy regarding diagnosis and optimal management when clear surgical guidelines are absent. In the literature, there is great diversity in the surgical approach to these patients, which leads to a high percentage of diagnostic errors, risks of complications, and unnecessary interventions. We review the literature and assess whether surgical intervention produces better outcomes than a non-surgical approach. Studies published on perianal sepsis in neutropenic cancer patients were identified by searching PubMed using the following key words: "perianal sepsis/abscesses, anorectal sepsis/abscess, neutropenia, hematological malignancy, cancer". No randomized or prospective studies on the management of acute perianal sepsis in hematological malignancies were found. The largest retrospective study and most comprehensive clinical data demonstrated that 42% of patients were treated successfully without surgical intervention and without morbidity or mortality related to treatment chosen. Small retrospective studies advocated surgical intervention, while the majority of successes were in a non-operative treatment. It is difficult to formulate a conclusion given the small retrospective series on management of neutropenic patients with hematological malignancies. While there is no evidence mandating a routine surgical approach in this category of patients, non-surgical management including careful follow-up to determine whether the patient's condition is deteriorating or treatment has failed is an acceptable approach in selected patients without pathognomonic features of abscess. Comprehensive and well-designed prospective studies are needed to firmly establish the guidelines of treatment

  17. Myeloid derived suppressor cells as therapeutic target in hematological malignancies

    Directory of Open Access Journals (Sweden)

    Kim eDe Veirman

    2014-12-01

    Full Text Available Myeloid derived suppressor cells (MDSC are a heterogeneous population of immature myeloid cells that accumulate during pathological conditions such as cancer and are associated with a poor clinical outcome. MDSC expansion hampers the host anti-tumor immune response by inhibition of T cell proliferation, cytokine secretion and recruitment of regulatory T cells. In addition, MDSC exert non-immunological functions including the promotion of angiogenesis, tumor invasion and metastasis. Recent years, MDSC are considered as a potential target in solid tumors and hematological malignancies to enhance the effects of currently used immune modulating agents. This review focuses on the characteristics, distribution, functions, cell-cell interactions and targeting of MDSC in hematological malignancies including multiple myeloma, lymphoma and leukemia.

  18. The feasibility of implementing a communication skills training course in pediatric hematology/oncology fellowship.

    Science.gov (United States)

    Weintraub, Lauren; Figueiredo, Lisa; Roth, Michael; Levy, Adam

    Communication skills are a competency highlighted by the Accreditation Council on Graduate Medical Education; yet, little is known about the frequency with which trainees receive formal training or what programs are willing to invest. We sought to answer this question and designed a program to address identified barriers. We surveyed pediatric fellowship program directors from all disciplines and, separately, pediatric hematology/oncology fellowship program directors to determine current use of formal communication skills training. At our institution, we piloted a standardized patient (SP)-based communication skills training program for pediatric hematology/oncology fellows. Twenty-seven pediatric hematology/oncology program directors and 44 pediatric program directors participated in the survey, of which 56% and 48%, respectively, reported having an established, formal communication skills training course. Multiple barriers to implementation of a communication skills course were identified, most notably time and cost. In the pilot program, 13 pediatric hematology/oncology fellows have participated, and 9 have completed all 3 years of training. Precourse assessment demonstrated fellows had limited comfort in various areas of communication. Following course completion, there was a significant increase in self-reported comfort and/or skill level in such areas of communication, including discussing a new diagnosis (p =.0004), telling a patient they are going to die (p =.005), discussing recurrent disease (p communicating a poor prognosis (p =.002), or responding to anger (p ≤.001). We have designed a concise communication skills training program, which addresses identified barriers and can feasibly be implemented in pediatric hematology/oncology fellowship.

  19. Azadirachtin, a neem-derived biopesticide, impairs behavioral and hematological parameters in carp (Cyprinus carpio).

    Science.gov (United States)

    Murussi, Camila R; Menezes, Charlene C; Nunes, Mauro E M; Araújo, Maria do Carmo S; Quadros, Vanessa A; Rosemberg, Denis B; Loro, Vania L

    2016-11-01

    Azadirachtin (Aza) is a promisor biopesticide used in organic production and aquaculture. Although this compound is apparently safe, there is evidence that it may have deleterious effects on fish. Behavioral and hematological tests are grouped into a set of parameters that may predict potential toxicity of chemical compounds. Here, we investigate the effects of Aza, in the commercial formulation Neenmax ™ , on carp (Cyprinus carpio) by defining LC 50 (96 h), and testing behavioral and hematological parameters. In our study, LC 50 was estimated at 80 μL/L. We exposed carp to Aza at 20, 40, and 60 μL/L, values based on 25, 50, and 75% of LC 50 , respectively. At 60 μL/L, Aza promoted significant changes in several parameters, increasing the distance traveled and absolute turn angle. In addition, the same concentration decreased the time spent immobile and the number of immobile episodes. Hematological parameters, such as hematocrit, hemoglobin, hematimetrics index, and red cell distribution, were decreased at 60 μL/L Aza exposure. In conclusion, our study demonstrates that 60 μL/L Aza altered locomotor activity, motor pattern, and hematological parameters, suggesting potential toxicity to carp after acute exposure. In addition, this is the first report that evaluates the actions of a chemical contaminant using automated behavioral tracking of carp, which may be a useful tool for assessing the potential toxicity of biopesticides in conjunction with hematological tests. © 2015 Wiley Periodicals, Inc. Environ Toxicol 31: 1381-1388, 2016. © 2015 Wiley Periodicals, Inc.

  20. Well-directed inclusion of hematology in African national cancer control plans.

    Science.gov (United States)

    Weaver, Meaghann; Yao, Atteby J J; Renner, Lorna; Harif, Mhamed; Lam, Catherine G

    2017-07-01

    In the context of a convergent call for noncommunicable disease integration in the global agenda, recognizing cross-cutting needs and opportunities in national strategies across disease fields with shared priorities in low- and middle-income settings can enhance sustainable development approaches. We reviewed publicly available cancer control plans in Africa to evaluate for inclusion of hematology needs and shared service priorities. Pediatric data remain sparse in cancer control plans. While continental Africa represents incredible diversity, recognizing shared priorities and opportunity for collaboration between oncology and hematology services and across age groups may guide prioritized cancer control efforts and reduce programmatic redundancies in resource-limited settings. © 2017 Wiley Periodicals, Inc.

  1. Site location and optical properties of Eu implanted sapphire

    International Nuclear Information System (INIS)

    Marques, C.; Wemans, A.; Maneira, M.J.P.; Kozanecki, A.; Silva, R.C. da; Alves, E.

    2005-01-01

    Synthetic colourless transparent (0 0 0 1) sapphire crystals were implanted at room temperature with 100 keV europium ions to fluences up to 1 x 10 16 cm -2 . Surface damage is observed at low fluences, as seen by Rutherford backscattering spectrometry under channelling conditions. Optical absorption measurements revealed a variety of structures, most probably related to F-type defects characteristic of implantation damage. Thermal treatments in air or in vacuum up to 1000 deg. C do not produce noticeable changes both in the matrix or the europium profiles. However, the complete recovery of the implantation damage and some redistribution of the europium ions is achieved after annealing at 1300 deg. C in air. Detailed lattice site location studies performed for various axial directions allowed to assess the damage recovery and the incorporation of the Eu ions into well defined crystallographic sites, possibly in an oxide phase also inferred from optical absorption measurements

  2. Preparation and modification of VO2 thin film on R-sapphire substrate by rapid thermal process

    International Nuclear Information System (INIS)

    Zhu Nai-Wei; Hu Ming; Xia Xiao-Xu; Wei Xiao-Ying; Liang Ji-Ran

    2014-01-01

    The VO 2 thin film with high performance of metal–insulator transition (MIT) is prepared on R-sapphire substrate for the first time by magnetron sputtering with rapid thermal process (RTP). The electrical characteristic and THz transmittance of MIT in VO 2 film are studied by four-point probe method and THz time domain spectrum (THz-TDS). X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and search engine marketing (SEM) are employed to analyze the crystalline structure, valence state, surface morphology of the film. Results indicate that the properties of VO 2 film which is oxidized from the metal vanadium film in oxygen atmosphere are improved with a follow-up RTP modification in nitrogen atmosphere. The crystallization and components of VO 2 film are improved and the film becomes compact and uniform. A better phase transition performance is shown that the resistance changes nearly 3 orders of magnitude with a 2-°C hysteresis width and the THz transmittances are reduced by 64% and 60% in thermal and optical excitation respectively. (interdisciplinary physics and related areas of science and technology)

  3. Karyotype in secondary hematologic disorders after treatment for Hodgkin's disease. A study of 19 patients

    International Nuclear Information System (INIS)

    Iurlo, A.; Mecucci, C.; Van Orshoven, A.; Michaux, J.L.; Boogaerts, M.; Van den Berghe, H.

    1988-01-01

    In 19 cases of secondary hematologic disorders in patients previously treated for Hodgkin's disease, chromosome aberrations were analyzed in relation to the type of previous chemo- and/or radiotherapy, age of the patients, histopathologic features of the Hodgkin's disease at diagnosis, time interval between the treatment and the occurrence of the secondary disorder, and survival. The karyotype was of significant prognostic value when three cytogenetic groups were considered: patients with normal karyotypes; patients with aberrations of chromosome 7 as the sole anomaly; and patients with complex rearrangements and translocations. The last group showed the lowest rate of survival. Bone marrow transplantation was successful in two patients with a normal karyotype

  4. Effects of occupational exposure of X-Ray on hematological parameters of diagnostic technicians

    Science.gov (United States)

    Taqi, Ali H.; Faraj, Kharman A.; Zaynal, Sarah A.; Hameed, Ahmed M.; Mahmood, Abd-Alkader A.

    2018-06-01

    The aim of this study was to identify the effects of long term exposure of X-ray on diagnostic technicians which they work at Kirkuk hospitals through examining some hematological parameters which are white blood cells (WBC), Neutrophils, Lymphocyte, Monocyte, Eosinophil, Basophil, Reactive Lymphocyte, red blood cells (RBC), hemoglobin (Hb), hematocrit (HCT), Mean Cell Volume (MCV), Mean Corpuscular Hemoglobin (MCH), Mean Cell Hemoglobin Concentration (MCHC), Red Cell Distribution Width (RDW), Platelet (PLT). The study included 54 male diagnostic technicians and 54 male healthy controls match with the first group to show any alteration of the hematological parameters. The diagnostic technicians divided into two groups depending on their work experience and hours working per day. The statistical analysis was performed using (Graph-pad) program. Our results showed that the Complete blood cells count (CBC) parameters (Neutrophil, Monocytes, Basophile, MCV, RDW and PLT) significantly (Pgroups of the diagnostic technicians compared with their controls. We concluded that chronic exposure of X-ray can significantly alter some hematological parameters and the number of hours working per day has observable effects on the some hematological parameters. We recommended training and courses about hazard of ionizing radiation should be organized for enhance the healthcare quality of the technicians and to improve their knowledge about benefit of radiation protection tools to protect themselves from any overexposure during the daily life.

  5. Biological Reference Interval for Hematological Profile of Umbilical Cord Blood: A Study Conducted at A Tertiary Care Centre in South India

    Science.gov (United States)

    Raj, Reddy S. Sudheer; Priyathersini, N.; Rajendran, Rithika; Rajendran, Rashmika; Ramadoss, Umalakshmi

    2015-01-01

    Introduction Umbilical cord blood (UCB) a source of hematopoietic stem cells, is also an acceptable sample to assess neonatal sepsis. Though reports are available for stem cell counts very minimal literature is available regarding hematologic parameters, which may vary on ethnicity. Aim To establish biological reference interval for hematological parameters of umbilical cord blood to guide neonatologists, hematopoietic stem cell transplant specialists and future analysis. Materials and Methods Prospective longitudinal study was done from January 2014 to April 2014 after ethics committee approval. UCB from 120 full term new borns of normal birth weight born out of uneventful pregnancy to mothers aged between 21 to 45 years with hemoglobin above 10g/dL were processed in Beckman Coulter LH780 analyzer for complete blood count and counter checked by peripheral smear. Results tabulated in Microsoft excel are analyzed using IBM SPSS statistics 16 software. Results Male to female ratio is 1:1.05. There is no difference in the values between males and females. When compared with few studies available, though many values are comparable a few values are not comparable. Conclusion This study can be a useful guide to neonatologists, hematopoietic stem cells transplant hematologists and future analysis. PMID:26557584

  6. Hematology and serum chemistry reference ranges of free-ranging moose (Alces Alces) in Norway

    OpenAIRE

    Rostal, Melinda K.; Evans, Alina L.; Solberg, Erling L.; Arnemo, Jon Martin

    2012-01-01

    This article is also available here: http://www.jwildlifedis.org/ Baseline reference ranges of serum chemistry and hematology data can be important indicators for the status of both individuals or populations of wild animals that are affected by emerging pathogens, toxicants, or other causes of disease. Frequently, reference ranges for these values are not available for wildlife species or subspecies. We present hematologic and serum chemistry reference ranges for moose (Alces ...

  7. Do Elderly Patients With Non-hematologic Malignancies Have A Worse Outcome in the ICU?

    Directory of Open Access Journals (Sweden)

    Tzu-Tao Chen

    2009-12-01

    Conclusion: The main cause of death and survival rates, both short-term and long-term, were not worse in elderly patients with non-hematologic malignancies in the ICU, and the main reasons for patient death were sepsis and respiratory failure, rather than the malignancy itself. Therefore, an ICU admission policy should not exclude elderly patients with non-hematologic malignancies merely because of concerns about survival rate or life expectancy.

  8. Growth and hematology of juvenile pacu Piaractus mesopotamicus (Holmberg 1887 fed with increasing levels of vitamin E (DL-α-tocopheryl acetate

    Directory of Open Access Journals (Sweden)

    RICARDO Y. SADO

    2013-03-01

    Full Text Available Intensive fish production systems are characterized by 100% artificial feeding, so any dietary imbalances or deficiencies may lead to diseases outbreaks and economic losses. This study was set out to determine the effects of increasing levels of dietary vitamin E on growth and hematology of juvenile pacu. Fishes were fed for 90 days, twice a day until apparent satiation with semi-purified diets containing 0.0; 25; 50; 150; 300 or 600 mg.kg−1 diet DL-α-tocopheryl acetate in a completely randomized design trial (n=4; biometrical and hematological data were collected and analyzed. Fishes fed with vit E diet (150 mg.kg−1 showed higher (p<0.05 weight gain and specific growth. Hematocrit, erythroblast number and total plasma protein were increased (p<0.05 in fishes fed diet with no vit E diet. Vitamin E supplementation in artificial diets for pacu is essential for growth and maintenance of normal erythropoiesis.

  9. The effect of Ramadan fasting on hematological parameters

    Directory of Open Access Journals (Sweden)

    Jafar Nasiri

    2016-12-01

    Full Text Available Background: Ramadan fasting is an obligation for many Muslims around the world who abstain from eating and drinking for one month, which has different medical and physiological effects, such as reducing blood pressure, lipid profile, blood glucose, and body weight. It has also been hypothesized that Ramadan fasting may induce some changes in the hematologic parameters. Thus, we aimed to investigate the effect of Ramadan fasting on blood cell count (CBC, and erythrocyte sedimentation rate (ESR. Methods: In the present study, 59 adult healthy individuals, who had completed one month of Ramadan fasting were included. Fasting blood samples were analyzed for ESR, hemoglobin (Hb, hematocrit (Hct, white blood cell (WBC, platelet count (PLT, mean corpuscular Volume (MCV and mean platelet volume (MPV, one day before, on the second and last week of Ramadan and one month after Ramadan (phase I , II, III,  and IV, respectively. Results: 34 men and 25 women with an age range of 15 to 24 years participated in the study. Mean ESR increased significantly (except phase IV, in comparison phase III. Mean Hb and Hct levels were significantly greater in phase III than phase I (P

  10. Hematology, plasma chemistry, and bacteriology of wild Tundra Swans (Cygnus columbianus) in Alaska.

    Science.gov (United States)

    Milani, Juliana F; Wilson, Heather; Ziccardi, Michael; LeFebvre, Rance; Scott, Cheryl

    2012-01-01

    Blood and cloacal swabs were collected from 100 (66 female, 34 male) wild Tundra Swans (Cygnus columbianus) molting in northwestern Alaska, USA, 25-28 July 2008, to establish hematologic and serum chemistry reference values and to isolate enteric Salmonella spp. and Escherichia coli O157:H7. Plasma biochemistry and hematology values did not vary significantly by sex or age. Tundra swans had high levels of creatine kinase, lactate dehydrogenase, amylase, and alkaline phosphatase compared with some other avian species (values were up to 7 times greater), possibly indicating capture myopathy. However, concentrations were much lower (up to 8 times lower) than in other waterfowl exposed to similar or more intensive capture methods. White blood cell count and hematocrit values were similar to other waterfowl species, and enteric Salmonella spp. and E. coli O157:H7 were not present among birds sampled. Our data provide the first biochemical, hematologic, and bacteriologic reference values for wild Tundra Swans.

  11. Comparison of hematologic and serologic profiles of broiler birds with normal and severe degrees of white striping in breast fillets.

    Science.gov (United States)

    Kuttappan, V A; Huff, G R; Huff, W E; Hargis, B M; Apple, J K; Coon, C; Owens, C M

    2013-02-01

    White striping is the white striation occasionally observed parallel to the direction of muscle fibers in broiler breast fillets and thighs at the processing plant. Broiler breast fillets can be categorized as normal (NORM), moderate (MOD), or severe (SEV) based on the degree of white striping. Histologically, SEV fillets are characterized by the highest degree of degeneration of muscle fibers along with fibrosis and lipidosis when compared with NORM. The present study was undertaken to compare the hematologic and serologic profiles of broilers with NORM and SEV degrees of white striping to get more information on the systemic changes associated with the condition. Day-old male broiler chicks of a commercial strain were grown on the same diet in 6 replicate pens (n = 32 birds/pen). Blood samples (5 mL) were collected from the wing vein of each bird on the day before processing for analyzing hematologic and serologic profiles. At 63 d, the birds were weighed and processed in a commercial inline processing system. Weight of the butterfly fillets, liver, and abdominal fat pad were recorded. Left-side fillets were scored to obtain the degree of white striping for each bird. Representative samples for NORM (n = 24) and SEV (n = 17) categories were selected to compare the hematologic and serologic profiles. The SEV birds had greater (P white striping. The elevated serum enzyme levels confirm the muscle damage associated with the degenerative myopathy in SEV birds.

  12. Role of Microvessel Density and Vascular Endothelial Growth Factor in Angiogenesis of Hematological Malignancies

    Directory of Open Access Journals (Sweden)

    Rashika Chand

    2016-01-01

    Full Text Available Angiogenesis plays an important role in progression of tumor with vascular endothelial growth factor (VEGF being key proangiogenic factor. It was intended to study angiogenesis in different hematological malignancies by quantifying expression of VEGF and MVD in bone marrow biopsy along with serum VEGF levels and observing its change following therapy. The study included 50 cases of hematological malignancies which were followed for one month after initial therapy along with 30 controls. All of them were subjected to immunostaining by anti-VEGF and factor VIII antibodies on bone marrow biopsy along with the measurement of serum VEGF levels. Significantly higher pretreatment VEGF scores, serum VEGF levels, and MVD were observed in cases as compared to controls (p<0.05. The highest VEGF score and serum VEGF were observed in chronic myeloid leukemia and maximum MVD in Non-Hodgkin’s Lymphoma. Significant decrease in serum VEGF levels after treatment was observed in all hematological malignancies except for AML. To conclude angiogenesis plays an important role in pathogenesis of all the hematological malignancies as reflected by increased VEGF expression and MVD in bone marrow biopsy along with increased serum VEGF level. The decrease in serum VEGF level after therapy further supports this view and also lays the importance of anti angiogenic therapy.

  13. Hematology, plasma biochemistry, and tissue enzyme activities of invasive red lionfish captured off North Carolina, USA.

    Science.gov (United States)

    Anderson, E T; Stoskopf, M K; Morris, J A; Clarke, E O; Harms, C A

    2010-12-01

    The red lionfish Pterois volitans is important not only in the aquarium trade but also as an invasive species in the western Atlantic. Introduced to waters off the southeastern coast of the United States, red lionfish have rapidly spread along much of the East Coast and throughout Bermuda, the Bahamas, and much of the Caribbean. Hematology and plasma biochemistry were evaluated in red lionfish captured from the offshore waters of North Carolina to establish baseline parameters for individual and population health assessment. Blood smears were evaluated for total and differential white blood cell counts, and routine clinical biochemical profiles were performed on plasma samples. To improve the interpretive value of routine plasma biochemistry profiles, tissue enzyme activities (alkaline phosphatase [ALP], alanine aminotransferase [ALT], aspartate aminotransferase [AST], gamma-glutamyl transferase [GGT], lactate dehydrogenase [LD], and creatine kinase [CK]) were analyzed from liver, kidney, skeletal muscle, gastrointestinal tract, and heart tissues from five fish. The hematological and plasma biochemical values were similar to those of other marine teleosts except that the estimated white blood cell counts were much lower than those routinely found in many species. The tissue enzyme activity findings suggest that plasma LD, CK, and AST offer clinical relevance in the assessment of red lionfish.

  14. Kinetics of dissolution of sapphire in melts in the CaO-Al2O3-SiO2 system

    Science.gov (United States)

    Shaw, Cliff S. J.; Klausen, Kim B.; Mao, Huahai

    2018-05-01

    The dissolution rate of sapphire in melts in the CAS system of varying silica activity, viscosity and degree of alumina saturation has been determined at 1600 °C and 1.5 GPa. After an initiation period of up to 1800 s, dissolution is controlled by diffusion of cations through the boundary layer adjacent to the dissolving sapphire. The dissolution rate decreases with increasing silica activity, viscosity and molar Al2O3/CaO. The calculated diffusion matrix for each solvent melt shows that CAS 1 and 9 which have molar Al2O3/CaO of 0.33 and 0.6 and dissolution rate constants of 0.65 × 10-6 and 0.59 × 10-6 m/s0.5 have similar directions and magnitudes of diffusive coupling: DCaO-Al2O3 and DAl2O3-CaO are both negative are approximately equal. The solvent with the fastest dissolution rate: CAS 4, which has a rate constant of 1.5 × 10-6 m/s0.5 and Al2O3/CaO of 0.31 has positive DCaO-Al2O3 and negative DAl2O3-CaO and the absolute values vary by a factor of 4. Although many studies show that aluminium is added to the melts via the reaction: Si4+ =Al3+ + 0.5Ca2+ the compositional profiles show that this reaction is not the only one involved in accommodating the aluminium added during sapphire dissolution. Rather, aluminium is incorporated as both tetrahedrally coordinated Al charge balanced by Ca and as aluminium not charge balanced by Ca (termed Alxs). This reaction: AlIV -Ca =Alxs +CaNBO where CaNBO is a non-bridging oxygen associated with calcium, may involve the formation of aluminium triclusters. The shape of the compositional profiles and oxide-oxide composition paths is controlled by the aluminium addition reaction. When Alxs exceeds 2%, CaO diffusion becomes increasingly anomalous and since the bond strength of Alxs correlates with CaO/CaO + Al2O3, the presence of more than 2% Alxs leads to significantly slower dissolution than when Alxs is absent or at low concentration. Thus, dissolution is controlled by diffusion of cations through the boundary layer, but this

  15. A Retrospective Mid- and Long-term Follow-up Study on the Changes in Hematologic Parameters in the Highly Exposed Residents of the Hebei Spirit Oil Spill in Taean, South Korea

    Science.gov (United States)

    Choi, Young-Hyun; Hong, Jee-Young; Lee, Moo-Sik

    2017-01-01

    Objectives This study aimed to analyze changes in hematologic parameters in the residents of the areas highly contaminated by the Hebei Spirit Oil Spill in 2007 and those who participated in the clean-up activities. Methods According to demographic characteristics, health status and behavior, and level of exposure to oil, we compared the hematologic results in 2009 and 2012 among 701 residents. The hematologic parameters were composed of white blood cell (WBC) count, and levels of hemoglobin, hematocrit (Hct), aspartate aminotransferase (AST), alanine aminotransferase (ALT), glucose, glycosylated hemoglobin (HbA1c), blood urea nitrogen (BUN), creatinine (Cr), total cholesterol (T-chol), high-density lipoprotein (HDL), and triglyceride (TG). Results Paired t-test revealed that the WBC count and levels of Hct, AST, ALT, glucose, and HbA1c significantly increased, whereas the BUN, Cr, HDL, and TG levels significantly decreased. Multiple linear regression modelling showed a relationship between the level of exposure to oil and temporal changes in Hct, glucose, HbA1c, and BUN levels. Conclusion Our results suggest a relationship between level of exposure to oil and changes in hematologic parameters over 3 years. Further studies should be conducted to determine the impact of oil spill on health such as the occurrence of diseases. PMID:29164048

  16. Patients' reflections on communication in the second-opinion hematology-oncology consultation.

    Science.gov (United States)

    Goldman, Roberta E; Sullivan, Amy; Back, Anthony L; Alexander, Stewart C; Matsuyama, Robin K; Lee, Stephanie J

    2009-07-01

    The nature of communication between patients and their second-opinion hematology consultants may be very different in these one-time consultations than for those that are within long-term relationships. This study explored patients' perceptions of their second-opinion hematology-oncology consultation to investigate physician-patient communication in malignant disease at a critical juncture in cancer patients' care and decision-making. In-depth telephone interviews with a subset of 20 patients from a larger study, following their subspecialty hematology consultations. Most patients wanted to contribute to the consultation agenda, but were unable to do so. Patients sought expert and honest advice delivered with empathy, though most did not expect the consultant to directly address their emotions. They wanted the physician to apply his/her knowledge to the specifics of their individual cases, and were disappointed and distrustful when physicians cited only general prognostic statistics. In contrast, physicians' consideration of the unique elements of patients' cases, and demonstrations of empathy and respect made patients' feel positively about the encounter, regardless of the prognosis. Patients provided concrete recommendations for physician and patient behaviors to enhance the consultation. Consideration of these recommendations may result in more effective communication and increased patient satisfaction with medical visits.

  17. Hematological clozapine monitoring with a point-of-care device

    DEFF Research Database (Denmark)

    Nielsen, Jimmi; Thode, Dorrit; Stenager, Elsebeth

    2012-01-01

    for several reasons, perhaps most importantly because of the mandatory hematological monitoring. The Chempaq Express Blood Counter (Chempaq XBC) is a point-of-care device providing counts of white blood cells (WBC) and granulocytes based on a capillary blood sampling. A randomized cross-over trial design...

  18. XPS and ToF-SIMS analysis of natural rubies and sapphires heat-treated in a reducing (5 mol% H 2/Ar) atmosphere

    Science.gov (United States)

    Achiwawanich, S.; James, B. D.; Liesegang, J.

    2008-12-01

    Surface effects on Mong Hsu rubies and Kanchanaburi sapphires after heat treatment in a controlled reducing atmosphere (5 mol% H 2/Ar) have been investigated using advanced surface science techniques including X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Visual appearance of the gemstones is clearly affected by the heat treatment in a reducing atmosphere. Kanchanaburi sapphires, in particular, exhibit Fe-containing precipitates after the heat treatment which have not been observed in previous studies under an inert atmosphere. Significant correlation between changes in visual appearance of the gemstones and variations in surface concentration of trace elements, especially Ti and Fe are observed. The XPS and ToF-SIMS results suggest that; (1) a reducing atmosphere affects the oxidation state of Fe; (2) dissociation of Fe-Ti interaction may occur during heat treatment.

  19. Polycrystalline Ba0.6Sr0.4TiO3 thin films on r-plane sapphire: Effect of film thickness on strain and dielectric properties

    Science.gov (United States)

    Fardin, E. A.; Holland, A. S.; Ghorbani, K.; Akdogan, E. K.; Simon, W. K.; Safari, A.; Wang, J. Y.

    2006-10-01

    Polycrystalline Ba0.6Sr0.4TiO3 (BST) films grown on r-plane sapphire exhibit strong variation of in-plane strain over the thickness range of 25-400nm. At a critical thickness of ˜200nm, the films are strain relieved; in thinner films, the strain is tensile, while compressive strain was observed in the 400nm film. Microwave properties of the films were measured from 1to20GHz by the interdigital capacitor method. A capacitance tunability of 64% was observed in the 200nm film, while thinner films showed improved Q factor. These results demonstrate the possibility of incorporating frequency agile BST-based devices into the silicon on sapphire process.

  20. Mid-IR absorption sensing of heavy water using a silicon-on-sapphire waveguide.

    Science.gov (United States)

    Singh, Neetesh; Casas-Bedoya, Alvaro; Hudson, Darren D; Read, Andrew; Mägi, Eric; Eggleton, Benjamin J

    2016-12-15

    We demonstrate a compact silicon-on-sapphire (SOS) strip waveguide sensor for mid-IR absorption spectroscopy. This device can be used for gas and liquid sensing, especially to detect chemically similar molecules and precisely characterize extremely absorptive liquids that are difficult to detect by conventional infrared transmission techniques. We reliably measure concentrations up to 0.25% of heavy water (D2O) in a D2O-H2O mixture at its maximum absorption band at around 4 μm. This complementary metal-oxide-semiconductor (CMOS) compatible SOS D2O sensor is promising for applications such as measuring body fat content or detection of coolant leakage in nuclear reactors.

  1. Hematology evaluation in workers exposed to ionizing radiation of a radiotherapy service

    International Nuclear Information System (INIS)

    Lopez P, G.; Frometa S, I.

    1996-01-01

    The verification of hematology indicators is performed as a routine at the initial and periodic evaluation of the health of workers which are exposed to ionizing radiation. In order to analyze the behavior of such indicators in connection with the exposure time and the received dose, a sample (n=74) of workers of the Radiotherapy Service in the Cancer Hospital in La Habana has been studied during 8 years. It was observed that the mean number of leucocytes, blood platelet and hemoglobin did not show meaningful variations and oscillated into normal limits; however an increase in the number of leukopenia cases was detected when the exposure time and the accumulated dose increased. This increase was two, three times higher in the last year of pursuit in connection with the initial value. (authors). 8 refs., 2 figs., 3 tabs

  2. End-of-Life Care for Blood Cancers: A Series of Focus Groups With Hematologic Oncologists

    Science.gov (United States)

    Odejide, Oreofe O.; Salas Coronado, Diana Y.; Watts, Corey D.; Wright, Alexi A.; Abel, Gregory A.

    2014-01-01

    Purpose: Hematologic cancers are associated with aggressive cancer-directed care near death and underuse of hospice and palliative care services. We sought to explore hematologic oncologists' perspectives and decision-making processes regarding end-of-life (EOL) care. Methods: Between September 2013 and January 2014, 20 hematologic oncologists from the Dana-Farber/Harvard Cancer Center participated in four focus groups regarding EOL care for leukemia, lymphoma, multiple myeloma, and hematopoietic stem-cell transplantation. Focus groups employed a semistructured format with case vignettes and open-ended questions and were followed by thematic analysis. Results: Many participants felt that identifying the EOL phase for patients with hematologic cancers was challenging as a result of the continuing potential for cure with advanced disease and the often rapid pace of decline near death. This difficulty was reported to result in later initiation of EOL care. Barriers to high-quality EOL care were also reported to be multifactorial, including unrealistic expectations from both physicians and patients, long-term patient-physician relationships resulting in difficulty conducting EOL discussions, and inadequacy of existing home-based EOL services. Participants also expressed concern that some EOL quality measures developed for solid tumors may be unacceptable for patients with blood cancers given their unique needs at the EOL (eg, palliative transfusions). Conclusion: Our analysis suggests that hematologic oncologists need better clinical markers for when to initiate EOL care. In addition, current quality measures may be inappropriate for identifying overly aggressive care for patients with blood cancers. Further research is needed to develop effective interventions to improve EOL care for this patient population. PMID:25294393

  3. Blood analysis in newborn donkeys: hematology, biochemistry, and blood gases analysis.

    Science.gov (United States)

    Veronesi, M C; Gloria, A; Panzani, S; Sfirro, M P; Carluccio, A; Contri, A

    2014-07-15

    The knowledge of reference ranges for hematologic, biochemical, and blood gas parameters in the different species and the influence of breed and age on them is a fundamental tool for the clinician. For this reason, the aim of this study was to evaluate the age-related changes of hematologic and biochemical parameters in Martina Franca donkey foals during the first 3 weeks of life and of blood gases during the first 24 hours of age. Fifteen healthy donkey foals were enrolled; blood samples were collected from each foal at 10 minutes after birth, 1 hour after the first and second suckles, 12 and 24 hours after birth, daily from Day 2 to 7, and at Days 10, 14, and 21 of life. Erythrocytes, leukocytes, and platelets counts were assessed; also metabolic (alanine aminotransferase, aspartate aminotransferase, gamma glutamyl transferase, creatinphospokinase, lactate dehydrogenase, alkaline phosphatase, glucose, blood urea nitrogen, creatinine, total proteins, albumins, cholesterol, and total bilirubin) and electrolytic parameters (Ca, P, Mg, Na, K, and Cl) were evaluated. Finally, blood gases and metabolic parameters (pH, pCO2, pO2, sO2, TCO2, HCO3, lactate, and base excess) on venous blood were assessed with a portable analyzer. A statistical analysis to evaluate the influence of age and sex was performed. Several differences were found between sampling times, demonstrating that age influences these parameters. Moreover differences were found compared with data reported in literature for donkey foals of another species, horse foals, and adult donkeys. Although a great interindividual variation for some parameters exists, this study demonstrated that interval references should be addressed not only to different species, but also to specific breeds and to the neonatal period. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Hematological and male hormonal profile of two cattle breeds ...

    African Journals Online (AJOL)

    Baseline data on the hematology of White Fulani and Muturu breeds of Cattle have been reported. However, very few documented studies have been carried out with regards to the reproductive hormonal profile of these breeds. Satisfactory reproductive performance is important to effective management and production as a ...

  5. Programming of the Wavelength Stabilization for a Titanium:Sapphire Laser using LabVIEW and Implementation into the CERN ISOLDE RILIS Measurement System

    CERN Document Server

    Rossel, Ralf Erik; Wendt, K; Rothe, S

    In the context of this work the foundation for the commissioning of a comprehensive environmental and operational data acquisition system was established. This development was performed for the Resonance Ionization Laser Ion Source (RILIS) at the ISOLDE radioactive ion beam facility within the European Organization for Nuclear Research CERN. As an essential step towards long-term automated operation, a remote control and wavelength stabilization system for the RILIS titanium:sapphire lasers was put into operation. This required the installation of a data recording infrastructure to work with a distributed sensor network. After operational data within the CERN technical computing network was collected and analyzed, the required wavelength adjustment was automatically performed by a stepper motor-driven correction system. The configuration of the hardware for acquisition and control and the integration of the dedicated system modules was performed using the graphical and data flow oriented programming language ...

  6. Monoclonal antibodies targeting CD38 in hematological malignancies and beyond

    DEFF Research Database (Denmark)

    van de Donk, Niels W C J; Janmaat, Maarten L.; Mutis, Tuna

    2016-01-01

    CD38 is a multifunctional cell surface protein that has receptor as well as enzyme functions. The protein is generally expressed at low levels on various hematological and solid tissues, while plasma cells express particularly high levels of CD38. The protein is also expressed in a subset of hema...... strong anti-tumor activity in preclinical models. The antibody engages diverse mechanisms of action, including complement-dependent cytotoxicity, antibody-dependent cellular cytotoxicity, antibody-dependent cellular phagocytosis, programmed cell death, modulation of enzymatic activity...... combination therapies with existing as well as emerging therapies, which are currently evaluated in the clinic. Finally, CD38 antibodies may have a role in the treatment of diseases beyond hematological malignancies, including solid tumors and antibody-mediated autoimmune diseases. © 2016 John Wiley & Sons A....../S. Published by John Wiley & Sons Ltd....

  7. Hematological and histological changes induced on the selected ...

    African Journals Online (AJOL)

    This study focused on the adverse effects of the extract of a mixture of 11 different herbs on the hematology and histology of liver, and kidney of rats. 20 rats were grouped into four different groups of 5 and were administered concentrations of 100mgkg-1, 200mgkg-1, 400mgkg-1 and the last group as control for 29 days.

  8. Effects of brewer's dried grain consumption on hematological ...

    African Journals Online (AJOL)

    One hundred, 22 weeks old Nera black pullet were used in eight weeks feeding trial to assess the effects of brewer's dried grain (BDG) as energy source on hematological profile of the birds. Five experimental diets were formulated in which T1, T2, T3, T4, T5 contained 0, 25, 50, 75 and 100% BDG respectively. The laying ...

  9. Central and peripheral distribution of bone marrow on bone marrow scintigraphy with antigranulocytic antibody in hematologic malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young [Dong-A University College of Medicne, Busan (Korea, Republic of); Lee, Jae Tae; Sohn, Sang Kyun; Lee, Kyu Bo [Kyungpook National University School of Medicine, Taegu (Korea, Republic of)

    2002-10-01

    Bone marrow scintigraphy has been used to evaluate the status of bone marrow in various hematologic disorders. We have analyzed the peripheral distribution pattern and central uptake ratio of bone marrow using anti-NCA-95 monoclonal antibody and the their correlation in patients with various hematologic malignancy. Bone marrow immunoscintigraphy was performed using Tc-99m anti-granulocyte monoclonal mouse antibody BW 250/183. Fifty patients were classified into four groups; 11 with acute myelogenous leukemia, 12 with acute lymphocytic leukemia, 15 with lymphoma and 12 with myelodysplastic syndrome. Th extension of peripheral bone marrow was categorized into four grades: I, II, III and IV. The activity of central bone marrow was expressed as sacroiliac uptake ratio. The patient's number was 4 in grade I, 27 in grade II, 15 in grade III and 4 in grade IV according to extension of peripheral bone marrow. The extension of peripheral bone marrow was marked (58% in grade III and IV) in myelodysplastic syndrome and acute lymphocytic leukemia and mild (93% in grade I and II) in lymphoma. Sacroiliac uptake ratio was highest (8.5{+-}4.0) in myelodysplastic syndrome and lowest (5.9{+-}3.6) in acute myelogenous leukemia, but not significantly different among four grades (p=0.003), but there was not correlated between grade of peripheral bone marrow and sacroiliac uptake ratio (r=0.05). Sacroiliac uptake ratio of whole patients was significantly different among four grades (p=0.003), but there was not correlated between grade of peripheral bone marrow and sacroiliac uptake ratio (r=0.05). The pattern of peripheral bone marrow extension and activity of central hemopoietic marrow were not specific to the disease entities. Response of hemopoietic bone marrow may be evaluated on both peripheral and central bone marrow in patients with hematologic malignancy.

  10. Central and peripheral distribution of bone marrow on bone marrow scintigraphy with antigranulocytic antibody in hematologic malignancy

    International Nuclear Information System (INIS)

    Kang, Do Young; Lee, Jae Tae; Sohn, Sang Kyun; Lee, Kyu Bo

    2002-01-01

    Bone marrow scintigraphy has been used to evaluate the status of bone marrow in various hematologic disorders. We have analyzed the peripheral distribution pattern and central uptake ratio of bone marrow using anti-NCA-95 monoclonal antibody and the their correlation in patients with various hematologic malignancy. Bone marrow immunoscintigraphy was performed using Tc-99m anti-granulocyte monoclonal mouse antibody BW 250/183. Fifty patients were classified into four groups; 11 with acute myelogenous leukemia, 12 with acute lymphocytic leukemia, 15 with lymphoma and 12 with myelodysplastic syndrome. Th extension of peripheral bone marrow was categorized into four grades: I, II, III and IV. The activity of central bone marrow was expressed as sacroiliac uptake ratio. The patient's number was 4 in grade I, 27 in grade II, 15 in grade III and 4 in grade IV according to extension of peripheral bone marrow. The extension of peripheral bone marrow was marked (58% in grade III and IV) in myelodysplastic syndrome and acute lymphocytic leukemia and mild (93% in grade I and II) in lymphoma. Sacroiliac uptake ratio was highest (8.5±4.0) in myelodysplastic syndrome and lowest (5.9±3.6) in acute myelogenous leukemia, but not significantly different among four grades (p=0.003), but there was not correlated between grade of peripheral bone marrow and sacroiliac uptake ratio (r=0.05). Sacroiliac uptake ratio of whole patients was significantly different among four grades (p=0.003), but there was not correlated between grade of peripheral bone marrow and sacroiliac uptake ratio (r=0.05). The pattern of peripheral bone marrow extension and activity of central hemopoietic marrow were not specific to the disease entities. Response of hemopoietic bone marrow may be evaluated on both peripheral and central bone marrow in patients with hematologic malignancy

  11. Lansoprazole Exacerbates Pemetrexed-Mediated Hematologic Toxicity by Competitive Inhibition of Renal Basolateral Human Organic Anion Transporter 3.

    Science.gov (United States)

    Ikemura, Kenji; Hamada, Yugo; Kaya, Chinatsu; Enokiya, Tomoyuki; Muraki, Yuichi; Nakahara, Hiroki; Fujimoto, Hajime; Kobayashi, Tetsu; Iwamoto, Takuya; Okuda, Masahiro

    2016-10-01

    Pemetrexed, a multitargeted antifolate, is eliminated by tubular secretion via human organic anion transporter 3 (hOAT3). Although proton pump inhibitors (PPIs) are frequently used in cancer patients, the drug interaction between PPIs and pemetrexed remains to be clarified. In this study, we examined the drug interaction between pemetrexed and PPIs in hOAT3-expressing cultured cells, and retrospectively analyzed the impact of PPIs on the development of hematologic toxicity in 108 patients who received pemetrexed and carboplatin treatment of nonsquamous non-small cell lung cancer for the first time between January 2011 and June 2015. We established that pemetrexed was transported via hOAT3 (Km = 68.3 ± 11.1 µM). Lansoprazole, rabeprazole, pantoprazole, esomeprazole, omeprazole, and vonoprazan inhibited hOAT3-mediated uptake of pemetrexed in a concentration-dependent manner. The inhibitory effect of lansoprazole was much greater than those of other PPIs and the apparent IC50 value of lansoprazole against pemetrexed transport via hOAT3 was 0.57 ± 0.17 µM. The inhibitory type of lansoprazole was competitive. In a retrospective study, multivariate analysis revealed that coadministration of lansoprazole, but not other PPIs, with pemetrexed and carboplatin was an independent risk factor significantly contributing to the development of hematologic toxicity (odds ratio: 10.004, P = 0.005). These findings demonstrated that coadministration of lansoprazole could exacerbate the hematologic toxicity associated with pemetrexed, at least in part, by competitive inhibition of hOAT3. Our results would aid clinicians to make decisions of coadministration drugs to avoid drug interaction-induced side effects for achievement of safe and appropriate chemotherapy with pemetrexed. Copyright © 2016 by The American Society for Pharmacology and Experimental Therapeutics.

  12. Time to look beyond one-year mortality in critically ill hematological patients?

    Science.gov (United States)

    Moors, Ine; Benoit, Dominique D

    2014-02-11

    The spectacular improvement in long-term prognosis of patients with hematological malignancies since the 1980s, coupled with the subsequent improvement over the past decade in short- and mid-term survival in cases of critical illness, resulted in an increasing referral of such patients to the ICU. A remaining question, however, is how these patients perform in the long term with regard to survival and quality of life. Here we discuss the present multicenter study on survival beyond 1 year in critically ill patients with hematological malignancies. We conclude with suggestions on how we can further improve the long-term outcome of these patients.

  13. Hematology research output from Chinese authors and other countries: a 10-year survey of the literature.

    Science.gov (United States)

    Zhang, Lei; Ye, Xin; Sun, Yi; Deng, An-mei; Qian, Bao-hua

    2015-02-06

    Hematologic disease affects people of all ages worldwide. In the past decade, researchers have made great progress in the field of hematology. In the present study we compared the hematology research output from China and other countries (USA, Germany, UK, Japan and South Korea) over the past 10 years and 5 years. The related articles were extracted based on the PubMed database. We recorded the number of publications, clinical trials, randomized controlled trials, meta-analyses, case reports, reviews, citations, impact factors, articles in the top 10 journals and most published journals to assess the quantity and quality of research output in each region. A total of 120,641 hematology-related articles were published from 2004 to 2013. The USA accounted for 27.13% (32,732/120,641) of the publications, followed by Germany (7,479/120,641; 6.20%), Japan (6,347/120,641; 5.26%), the UK (5,453/120,641; 4.52%), China (2,924/120,641; 2.42%) and South Korea (1,413/120,641; 1.17%). The ranking for cumulative impact factors was as follows: USA; Germany; UK; Japan; China and South Korea. The median impact factors in the UK, USA, and Germany were higher than Japan, South Korea, and China. Interestingly, the median impact factors in the three Asia countries were similar both in 2004-2013 and 2009-2013. The UK had the highest percentage of publications in the top 25% of journals, while China lagged behind and ranked last. When comparing the number of articles in the top 10 journals, the results were similar to the IF findings. Germany had the highest number of average citations, while China had the lowest number of average citation. The status of hematology research output from the 6 countries in 2009-2013 had little difference from 2004-2013. Thus, the USA has had a dominant role in hematologic research in the past 10 years. Overall, the quality of publications in European countries was better than Asia countries. Although China has made considerable progress in hematology

  14. Formation of metal nanoparticles of various sizes in plasma plumes produced by Ti:sapphire laser pulses

    International Nuclear Information System (INIS)

    Chakravarty, U.; Naik, P. A.; Mukherjee, C.; Kumbhare, S. R.; Gupta, P. D.

    2010-01-01

    In this paper, an experimental study on generation of nanoparticle various sizes using Ti:sapphire laser pulses, is reported. Nanoparticle formation in plasma plumes of metals like silver and copper, expanding in vacuum, has been studied using stretched pulses of 300 ps duration [subnanoseconds (sub-ns)] from a Ti:sapphire laser. It has been compared with the nanoparticle formation (of the same materials) when compressed pulses of 45 fs duration were used under similar focusing conditions. Nanoparticle formation is observed at intensities as high as 2x10 16 W/cm 2 . The structural analysis of the nanoparticle deposition on a silicon substrate showed that, using 45 fs pulses, smaller nanoparticles of average size ∼20 nm were generated, whereas on using the sub-ns pulses, larger particles were produced. Also, the visible light transmission and reflection from the nanoparticle film of Ag on glass substrate showed surface plasmon resonance (SPR). The SPR curves of the films of nanoparticles deposited by femtosecond pulses were always broader and reflection/transmission was always smaller when compared with the films formed using the sub-ns pulses, indicating smaller size particle formation by ultrashort pulses. Thus, it has been demonstrated that variation in the laser pulse duration of laser offers a simple tool for varying the size of the nanoparticles generated in plasma plumes.

  15. Influence of Wallow on Some Hematological Parameters and Serum ...

    African Journals Online (AJOL)

    A study was conducted to determine the influence of wallow on some hematological and serum enzymes of growing pigs. Six pre-pubertal pigs of average age 2months were randomly assigned to two treatment groups, comprising of Wallow (A) and Non-Wallow facilities (B) in a Completely Randomized Design(CRD).

  16. Imaging in hematology. Part 1: Ultrasonography and conventional radiology

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    Applications of conventional ultrasonography techniques (B-mode or real time) in oncohematology are presented. The newer adaptations (in particular colour Doppler) provide incremental advantages that support their inclusion in the imaging techniques available to modern hematology. Conventional radiologic studies include chest and bone X-ray, gastrointestinal contrast examination and bipedal lymphangiography

  17. Two cases of paralitic ileus in onco-hematologic patients

    Directory of Open Access Journals (Sweden)

    Francesca Carraro

    2012-01-01

    Full Text Available ileus is a severe complication resulting from a variety of disorders. It occurs most commonly in patients with serious underlying medical or surgical conditions. Prompt diagnosis and appropriate management may improve the outcome. We describe 2 cases of onco-hematologic patients who presented this complication after intensive chemotherapy.

  18. Two cases of paralitic ileus in onco-hematologic patients

    Science.gov (United States)

    Carraro, Francesca; Rivetti, Elisa; Romano, Erica; Fagioli, Franca

    2012-01-01

    Paralytic ileus is a severe complication resulting from a variety of disorders. It occurs most commonly in patients with serious underlying medical or surgical conditions. Prompt diagnosis and appropriate management may improve the outcome. We describe 2 cases of onco-hematologic patients who presented this complication after intensive chemotherapy. PMID:22690309

  19. Kytococcus schroeteri Pneumonia in Two Patients with a Hematological Malignancy

    NARCIS (Netherlands)

    Hodiamont, C. J.; Huisman, C.; Spanjaard, L.; van Ketel, R. J.

    2010-01-01

    Neutropenic patients are susceptible to infections with usually harmless microorganisms. We report two cases of severe pneumonia in hematological patients due to Kytococcus schroeteri, a saprophyte of the human skin. When blood cultures or respiratory specimens yield micrococcus-like colonies,

  20. Design of patterned sapphire substrates for GaN-based light-emitting diodes

    International Nuclear Information System (INIS)

    Wang Hai-Yan; Lin Zhi-Ting; Han Jing-Lei; Zhong Li-Yi; Li Guo-Qiang

    2015-01-01

    A new method for patterned sapphire substrate (PSS) design is developed and proven to be reliable and cost-effective. As progress is made with LEDs’ luminous efficiency, the pattern units of PSS become more complicated, and the effect of complicated geometrical features is almost impossible to study systematically by experiments only. By employing our new method, the influence of pattern parameters can be systematically studied, and various novel patterns are designed and optimized within a reasonable time span, with great improvement in LEDs’ light extraction efficiency (LEE). Clearly, PSS pattern design with such a method deserves particular attention. We foresee that GaN-based LEDs on these newly designed PSSs will achieve more progress in the coming years. (topical review)