WorldWideScience

Sample records for sanitary sewer overflow

  1. DEP Reported Sanitary Sewer Overflows

    Data.gov (United States)

    Montgomery County of Maryland — Sanitary sewer overflows reported to the Department of Environmental Protection by the Washington Suburban Sanitary Commission or individuals in the County. Update...

  2. COMPUTER MODEL ANALYSIS FOR MITIGATION PLANNING OF SANITARY-SEWER OVERFLOWS

    Science.gov (United States)

    Sanitary sewer overflows (SSOs) are generally difficult to witness or document as they usually occur during rain events when people are indoors or out of sight. To anser where and when an SSO may occur, it is necessary to know the flow conveyance capacity at various parts of the ...

  3. COMBINED-SEWER OVERFLOW CONTROL AND TREATMENT

    Science.gov (United States)

    Combined-sewer overflow (CSO), along with sanitary-sewer overflow and stormwater are significant contributors of contamination to surface waters. During a rain event, the flow in a combined sewer system may exceed the capacity of the intercepting sewer leading to the wastewater t...

  4. 76 FR 35215 - Notice of EPA Workshop on Sanitary Sewer Overflows and Peak Wet Weather Discharges

    Science.gov (United States)

    2011-06-16

    ... maintained sanitary sewer systems are meant to collect and transport all of the sewage that flows into them... sewage from these overflows can contaminate our waters, causing serious water quality problems. It can... influent flows to exceed the treatment capacity of existing secondary treatment units. Known as ``peak...

  5. Sewer System Management Plan.

    Energy Technology Data Exchange (ETDEWEB)

    Holland, Robert C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-08-01

    A Sewer System Management Plan (SSMP) is required by the State Water Resources Control Board (SWRCB) Order No. 2006-0003-DWQ Statewide General Waste Discharge Requirements (WDR) for Sanitary Sewer Systems (General Permit). DOE, National Nuclear Security Administration (NNSA), Sandia Field Office has filed a Notice of Intent to be covered under this General Permit. The General Permit requires a proactive approach to reduce the number and frequency of sanitary sewer overflows (SSOs) within the State. SSMPs must include provisions to provide proper and efficient management, operation, and maintenance of sanitary sewer systems and must contain a spill response plan.

  6. Locations of Combined Sewer Overflow Outfalls - US EPA Region 3

    Science.gov (United States)

    This data layer identifies the locations of Combined sewer overflow outfalls. Combined sewer systems are sewers that are designed to collect rainwater runoff, domestic sewage, and industrial wastewater in the same pipe. Most of the time, combined sewer systems transport all of their wastewater to a sewage treatment plant, where it is treated and then discharged to a water body. During periods of heavy rainfall or snowmelt, however, the wastewater volume in a combined sewer system can exceed the capacity of the sewer system or treatment plant. For this reason, combined sewer systems are designed to overflow occasionally and discharge excess untreated wastewater directly to nearby streams, rivers, or other water bodies. For further information visit: http://cfpub1.epa.gov/npdes/home.cfm?program_id=5

  7. Using data from monitoring combined sewer overflows to assess, improve, and maintain combined sewer systems

    OpenAIRE

    Montserrat Royuela, Albert; Bosch, Ll.; Kiser, M.A.; Poch, Manuel; Corominas Tabares, Lluís

    2015-01-01

    Using low-cost sensors, data can be collected on the occurrence and duration of overflows in each combined sewer overflow (CSO) structure in a combined sewer system (CSS). The collection and analysis of real data can be used to assess, improve, and maintain CSSs in order to reduce the number and impact of overflows. The objective of this study was to develop a methodology to evaluate the performance of CSSs using low-cost monitoring. This methodology includes (1) assessing the capacity of a C...

  8. Locations of Combined Sewer Overflow Outfalls - US EPA Region 3

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer identifies the locations of Combined sewer overflow outfalls. Combined sewer systems are sewers that are designed to collect rainwater runoff,...

  9. Sandia National Laboratories, California sewer system management plan.

    Energy Technology Data Exchange (ETDEWEB)

    Holland, Robert C.

    2010-02-01

    A Sewer System Management Plan (SSMP) is required by the State Water Resources Control Board (SWRCB) Order No. 2006-0003-DWQ Statewide General Waste Discharge Requirements (WDR) for Sanitary Sewer Systems (General Permit). DOE, National Nuclear Security Administration (NNSA), Sandia Site Office has filed a Notice of Intent to be covered under this General Permit. The General Permit requires a proactive approach to reduce the number and frequency of sanitary sewer overflows (SSOs) within the State. SSMPs must include provisions to provide proper and efficient management, operation, and maintenance of sanitary sewer systems and must contain a spill response plan. Elements of this Plan are under development in accordance with the SWRCB's schedule.

  10. Urban runoff and combined sewer overflow. [Wastewater treatment

    Energy Technology Data Exchange (ETDEWEB)

    Moffa, P.E. (Calocerinos and Spina, Liverpool, NY); Freedman, S.D.; Owens, E.M.; Field, R.; Cibik, C.

    1982-06-01

    The control, treatment and management of urban runoff and sewer overflow are reviewed. Simplified modeling and monitoring techniques are used to characterize urban runoff and to assess control alternatives. (KRM)

  11. Using data from monitoring combined sewer overflows to assess, improve, and maintain combined sewer systems.

    Science.gov (United States)

    Montserrat, A; Bosch, Ll; Kiser, M A; Poch, M; Corominas, Ll

    2015-02-01

    Using low-cost sensors, data can be collected on the occurrence and duration of overflows in each combined sewer overflow (CSO) structure in a combined sewer system (CSS). The collection and analysis of real data can be used to assess, improve, and maintain CSSs in order to reduce the number and impact of overflows. The objective of this study was to develop a methodology to evaluate the performance of CSSs using low-cost monitoring. This methodology includes (1) assessing the capacity of a CSS using overflow duration and rain volume data, (2) characterizing the performance of CSO structures with statistics, (3) evaluating the compliance of a CSS with government guidelines, and (4) generating decision tree models to provide support to managers for making decisions about system maintenance. The methodology is demonstrated with a case study of a CSS in La Garriga, Spain. The rain volume breaking point from which CSO structures started to overflow ranged from 0.6 mm to 2.8 mm. The structures with the best and worst performance in terms of overflow (overflow probability, order, duration and CSO ranking) were characterized. Most of the obtained decision trees to predict overflows from rain data had accuracies ranging from 70% to 83%. The results obtained from the proposed methodology can greatly support managers and engineers dealing with real-world problems, improvements, and maintenance of CSSs. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. HIGH-RATE DISINFECTION TECHNIQUES FOR COMBIND SEWER OVERFLOW

    Science.gov (United States)

    This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH )...

  13. Estimation of combined sewer overflow discharge

    DEFF Research Database (Denmark)

    Ahm, Malte; Thorndahl, Søren Liedtke; Nielsen, Jesper Ellerbæk

    2016-01-01

    Combined sewer overflow (CSO) structures are constructed to effectively discharge excess water during heavy rainfall, to protect the urban drainage system from hydraulic overload. Consequently, most CSO structures are not constructed according to basic hydraulic principles for ideal measurement......-balance in combined sewer catchments. A closed mass-balance is an advantage for calibration of all urban drainage models based on mass-balance principles. This study presents three different software sensor concepts based on local water level sensors, which can be used to estimate CSO discharge volumes from hydraulic...... complex CSO structures. The three concepts was tested and verified under real practical conditions. All three concepts were accurate when compared to electromagnetic flow measurements....

  14. Cost Comparison of Conventional Gray Combined Sewer Overflow Control Infrastructure versus a Green/Gray Combination

    Science.gov (United States)

    This paper outlines a life-cycle cost analysis comparing a green (rain gardens) and gray (tunnels) infrastructure combination to a gray-only option to control combined sewer overflow in the Turkey Creek Combined Sewer Overflow Basin, in Kansas City, MO. The plan area of this Bas...

  15. Conceptual design report, 200 Area sanitary sewer system: Project 96L-EWL-116

    International Nuclear Information System (INIS)

    Pursley, D.L.

    1994-01-01

    Project L-116 will install an integrated sanitary sewer system in the 200 Area. This new system will connect existing sewer systems for facilities that have a foreseeable future, provide capacity and routing for future facilities, and install new septic sewer systems for existing facilities that cannot be feasibly connected to the new sewer system and have a mission that will extend beyond the year 2000. Project L-116 will construct a sanitary sewer collection, treatment, and disposal system for facilities in the 200-East and -West Areas and adjacent areas located on the 200 Area plateau. The existing septic systems will be abandoned or decommissioned in accordance with applicable Washington State and local codes and regulations. The conceptual design for the sanitary sewer system is designed around population forecasts of 5,000 people for 200-West Area and 9,000 people for 200-East Area. The definitive design will be based on the latest forecast populations at the time definitive design is initiated

  16. Effects of combined-sewer overflows and urban runoff on the water quality of Fall Creek, Indianapolis, Indiana

    Science.gov (United States)

    Martin, Jeffrey D.

    1995-01-01

    In 1986, the U.S. Geological Survey and the Indianapolis Department of Public Works began a study to evaluate the effects of combined-sewer overflows and urban runoff discharging to Fall Geek on the White River. This report describes the effects of combined-sewer overflows and urban runoff on the water quality of Fall Creek during summer 1987 by comparing the water quality during base flow with that during storm runoff and by comparing water quality in the urbanized area with that in the less urbanized area upstream from the combined-sewer overflows. Data were collected at three streamflow-gaging stations located upstream from, downstream from, and in the middle of 27 combined-sewer overflows on Fall Creek. The most downstream station also was immediately downstream from the discharge of filter backwash from a water-treatment plant for public supply.

  17. Effluent and sanitary sewer monitors

    International Nuclear Information System (INIS)

    Stanchi, L.; Vasey, M.R.

    1977-03-01

    Two similar instruments that monitor the liquid wastes from the plutonium facility are described. The operation of the two instruments is completely automatic and performs a continuous surveillance in the frame of Nuclear Safeguards. One instrument controls the liquids from the facility and the other checks the sanitary sewer wastes. Both have self-diagnosing capabilities and take automatic actions in case of abnormal occurrences

  18. Bacterial diversity impacts as a result of combined sewer overflow in a polluted waterway

    Directory of Open Access Journals (Sweden)

    O. Calderon

    2017-12-01

    Full Text Available Newtown Creek is an industrial waterway and former tidal wetland in New York City. It is one of the most polluted water bodies in the United States and was designated as a superfund site in 2010. For over a century, organic compounds, heavy metals, and other forms of industrial pollution have disrupted the creek’s environment. The creek is also impacted by discharges from twenty combined sewer overflow pipes, which may deposit raw sewage or partially treated wastewater directly into the creek during heavy or sustained rain events. Combined sewer overflow events and associated nutrient over-enrichment at the creek drive eutrophication and subsequent hypoxia. At the current study, three sites were sampled one week apart during a dry period and a wet period, where indication of a combined sewage overflow event could be detected. 16s rRNA high-throughput sequencing from these three sites collectively yielded over 1000 species of bacteria belonging to twenty-two classes. Based on these data, it is hypothesized that differences identified in the microbiome on wet versus dry days are as a result of combined sewage overflow, street runoff, and additional fluctuations in the creek’s environment associated with rain. It was found that after a combined sewer overflows event, the levels of Gamma Proteobacteria increased while the levels of Actinobacteria decreased. However, levels of bacteria stayed relatively unchanged at a site further away from combined sewer overflows discharge. Species found in Newtown Creek include pelagic, marine, human and animal pathogens, hydrocarbonoclastic, and other environmental microbes.

  19. Quantifying rainfall-derived inflow and infiltration in sanitary sewer systems based on conductivity monitoring

    Science.gov (United States)

    Zhang, Mingkai; Liu, Yanchen; Cheng, Xun; Zhu, David Z.; Shi, Hanchang; Yuan, Zhiguo

    2018-03-01

    Quantifying rainfall-derived inflow and infiltration (RDII) in a sanitary sewer is difficult when RDII and overflow occur simultaneously. This study proposes a novel conductivity-based method for estimating RDII. The method separately decomposes rainfall-derived inflow (RDI) and rainfall-induced infiltration (RII) on the basis of conductivity data. Fast Fourier transform was adopted to analyze variations in the flow and water quality during dry weather. Nonlinear curve fitting based on the least squares algorithm was used to optimize parameters in the proposed RDII model. The method was successfully applied to real-life case studies, in which inflow and infiltration were successfully estimated for three typical rainfall events with total rainfall volumes of 6.25 mm (light), 28.15 mm (medium), and 178 mm (heavy). Uncertainties of model parameters were estimated using the generalized likelihood uncertainty estimation (GLUE) method and were found to be acceptable. Compared with traditional flow-based methods, the proposed approach exhibits distinct advantages in estimating RDII and overflow, particularly when the two processes happen simultaneously.

  20. High-Rate Disinfection Techniques for Combined Sewer Overflow (Proceedings Paper)

    Science.gov (United States)

    This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH ), a...

  1. Sanitary sewer rehabilitation at Lawrence Livermore National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Vellinger, R. J.; Burton, R.; Fritschy, B.

    1995-04-01

    The objectives of this paper are the following: to present LLNL`s collection system and innovative approach to sanitary sewer rehabilitation; share issues identified and lessons learned from over four (4) years of rehabilitation work; and discuss proposed system standards for ongoing maintenance and repair activities.

  2. Evidence for fat, oil, and grease (FOG) deposit formation mechanisms in sewer lines.

    Science.gov (United States)

    He, Xia; Iasmin, Mahbuba; Dean, Lisa O; Lappi, Simon E; Ducoste, Joel J; de los Reyes, Francis L

    2011-05-15

    The presence of hardened and insoluble fats, oil, and grease (FOG) deposits in sewer lines is a major cause of line blockages leading to sanitary sewer overflows (SSOs). Despite the central role that FOG deposits play in SSOs, little is known about the mechanisms of FOG deposit formation in sanitary sewers. In this study, FOG deposits were formed under laboratory conditions from the reaction between free fatty acids and calcium chloride. The calcium and fatty acid profile analysis showed that the laboratory-produced FOG deposit displayed similar characteristics to FOG deposits collected from sanitary sewer lines. Results of FTIR analysis showed that the FOG deposits are metallic salts of fatty acid as revealed by comparisons with FOG deposits collected from sewer lines and pure calcium soaps. Based on the data, we propose that the formation of FOG deposits occurs from the aggregation of excess calcium compressing the double layer of free fatty acid micelles and a saponification reaction between aggregated calcium and free fatty acids.

  3. Detention storage volume for combined sewer overflow into a river.

    Science.gov (United States)

    Temprano, J; Tejero, I

    2002-06-01

    This article discusses the storage volume needed in a combined sewer system tank in order to preserve the water quality. There are a lot of design criteria which do not take into account the conditions of the receiving water, and as a result are inappropriate. A model was used to simulate the performance of a theoretical combined sewer system where a tank was located downstream. Results were obtained from the overflows produced by the rain recorded in Santander (Spain) for 11 years, with several combinations of storage volume and treatment capacity in the wastewater treatment plant. Quality criteria were also proposed for faecal coliforms, BOD, and total nitrogen to evaluate the effects from the overflows in the river water quality. Equations have been obtained which relate the number of overflows, the storage volume and the treatment plant capacity. The bacteriological pollution, quantified by means of faecal coliforms, was the analytical parameter which produced the most adverse effects in the river, so that more storage volume is needed (45 to 180 m3 ha(-1) net) than with other simulated pollutants (5 to 50 m3 ha(-1) net for BOD, and less than 4 m3 ha(-1) net for the total nitrogen). The increase in the treatment plant's capacity, from two to three times the flow in dry weather, reduces the impact on the river water in a more effective way, allowing a reduction of up to 65% in the number of overflows rather than increasing the storage volume.

  4. DSM-flux: A new technology for reliable Combined Sewer Overflow discharge monitoring with low uncertainties.

    Science.gov (United States)

    Maté Marín, Ainhoa; Rivière, Nicolas; Lipeme Kouyi, Gislain

    2018-06-01

    In the past ten years, governments from the European Union have been encouraged to collect volume and quality data for all the effluent overflows from separated stormwater and combined sewer systems that result in a significant environmental impact on receiving water bodies. Methods to monitor and control these flows require improvements, particularly for complex Combined Sewer Overflow (CSO) structures. The DSM-flux (Device for Stormwater and combined sewer flows Monitoring and the control of pollutant fluxes) is a new pre-designed and pre-calibrated channel that provides appropriate hydraulic conditions suitable for measurement of overflow rates and volumes by means of one water level gauge. In this paper, a stage-discharge relation for the DSM-flux is obtained experimentally and validated for multiple inflow hydraulic configurations. Uncertainties in CSO discharges and volumes are estimated within the Guide to the expression of Uncertainty in Measurement (GUM) framework. Whatever the upstream hydraulic conditions are, relative uncertainties are lower than 15% and 2% for the investigated discharges and volumes, respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. A software-based sensor for combined sewer overflows.

    Science.gov (United States)

    Leonhardt, G; Fach, S; Engelhard, C; Kinzel, H; Rauch, W

    2012-01-01

    A new methodology for online estimation of excess flow from combined sewer overflow (CSO) structures based on simulation models is presented. If sufficient flow and water level data from the sewer system is available, no rainfall data are needed to run the model. An inverse rainfall-runoff model was developed to simulate net rainfall based on flow and water level data. Excess flow at all CSO structures in a catchment can then be simulated with a rainfall-runoff model. The method is applied to a case study and results show that the inverse rainfall-runoff model can be used instead of missing rain gauges. Online operation is ensured by software providing an interface to the SCADA-system of the operator and controlling the model. A water quality model could be included to simulate also pollutant concentrations in the excess flow.

  6. New approach for receiving water objectives for overflows from sewer systems

    DEFF Research Database (Denmark)

    Larsen, Torben

    1999-01-01

    The paper describes the results of the work for the establishment of consistent objectives for storm overflows from sewer systems in respect to the physical conditions in streams and rivers in Denmark. First the result of a questionnaire is mentioned. Next some principles of the methods for formu...

  7. Water Quality of Combined Sewer Overflows, Stormwater, and Streams, Omaha, Nebraska, 2006-07

    Science.gov (United States)

    Vogel, Jason R.; Frankforter, Jill D.; Rus, David L.; Hobza, Christopher M.; Moser, Matthew T.

    2009-01-01

    The U.S. Geological Survey, in cooperation with the City of Omaha, investigated the water quality of combined sewer overflows, stormwater, and streams in the Omaha, Nebraska, area by collecting and analyzing 1,175 water samples from August 2006 through October 2007. The study area included the drainage area of Papillion Creek at Capeheart Road near Bellevue, Nebraska, which encompasses the tributary drainages of the Big and Little Papillion Creeks and Cole Creek, along with the Missouri River reach that is adjacent to Omaha. Of the 101 constituents analyzed during the study, 100 were detected in at least 1 sample during the study. Spatial and seasonal comparisons were completed for environmental samples. Measured concentrations in stream samples were compared to water-quality criteria for pollutants of concern. Finally, the mass loads of water-quality constituents in the combined sewer overflow discharges, stormwater outfalls, and streams were computed and compared. The results of the study indicate that combined sewer overflow and stormwater discharges are affecting the water quality of the streams in the Omaha area. At the Papillion Creek Basin sites, Escherichia coli densities were greater than 126 units per 100 milliliters in 99 percent of the samples (212 of 213 samples analyzed for Escherichia coli) collected during the recreational-use season from May through September (in 2006 and 2007). Escherichia coli densities in 76 percent of Missouri River samples (39 of 51 samples) were greater than 126 units per 100 milliliters in samples collected from May through September (in 2006 and 2007). None of the constituents with human health criteria for consumption of water, fish, and other aquatic organisms were detected at levels greater than the criteria in any of the samples collected during this study. Total phosphorus concentrations in water samples collected in the Papillion Creek Basin were in excess of the U.S. Environmental Protection Agency's proposed

  8. Modeling climate change impacts on combined sewer overflow using synthetic precipitation time series.

    Science.gov (United States)

    Bendel, David; Beck, Ferdinand; Dittmer, Ulrich

    2013-01-01

    In the presented study climate change impacts on combined sewer overflows (CSOs) in Baden-Wuerttemberg, Southern Germany, were assessed based on continuous long-term rainfall-runoff simulations. As input data, synthetic rainfall time series were used. The applied precipitation generator NiedSim-Klima accounts for climate change effects on precipitation patterns. Time series for the past (1961-1990) and future (2041-2050) were generated for various locations. Comparing the simulated CSO activity of both periods we observe significantly higher overflow frequencies for the future. Changes in overflow volume and overflow duration depend on the type of overflow structure. Both values will increase at simple CSO structures that merely divide the flow, whereas they will decrease when the CSO structure is combined with a storage tank. However, there is a wide variation between the results of different precipitation time series (representative for different locations).

  9. Management of sewer overflow structure in the FRG

    International Nuclear Information System (INIS)

    Leymann, G.

    1987-01-01

    Due to the geological morphology of the south and west of Germany, combined sewer systems are used to drain sewage and rain water in urban areas. In this system, industrial and domestic sewage as well as rain water flowing off areas with sealed surfaces are discharged into one pipe. Size and structure of this sewer system are designed to fulfil the criterium, that the total amount of water, stemming from rain events of an intensity not to be exceeded more than once a year, can be drained without flooding any part of the area considered. In the past, construction costs were reduced by building overflow structures at suitable sites; these structures discharge a volume of water exceeding five times the amount of water produced during dry weather in a most directly way in the outlet channel. In the sewage treatment plant, only two fifths of this remaining water volume was treated mechanically and biologically. Three fifths were discharged into the natural waters after mechanical treatment only

  10. NORTH PORTAL-SANITARY SEWER CALCULATION-SHOP BUILDING No.5006

    International Nuclear Information System (INIS)

    S. Blackstone

    1996-01-01

    The purpose of this design calculation is to determine the demand on the waste system and to size the sanitary sewer line serving the Shop Building No.5006 in accordance with the Uniform Plumbing Code (Section 4.4.1) and US Department of Energy Order 6430.1A-1540 (Section 4.4.2)

  11. Modelling sewer sediment deposition, erosion, and transport processes to predict acute influent and reduce combined sewer overflows and CO(2) emissions.

    Science.gov (United States)

    Mouri, Goro; Oki, Taikan

    2010-01-01

    Understanding of solids deposition, erosion, and transport processes in sewer systems has improved considerably in the past decade. This has provided guidance for controlling sewer solids and associated acute pollutants to protect the environment and improve the operation of wastewater systems. Although measures to decrease combined sewer overflow (CSO) events have reduced the amount of discharged pollution, overflows continue to occur during rainy weather in combined sewer systems. The solution lies in the amount of water allotted to various processes in an effluent treatment system, in impact evaluation of water quality and prediction technology, and in stressing the importance of developing a control technology. Extremely contaminated inflow has been a serious research subject, especially in connection with the influence of rainy weather on nitrogen and organic matter removal efficiency in wastewater treatment plants (WWTP). An intensive investigation of an extremely polluted inflow load to WWTP during rainy weather was conducted in the city of Matsuyama, the region used for the present research on total suspended solid (TSS) concentration. Since the inflow during rainy weather can be as much as 400 times that in dry weather, almost all sewers are unsettled and overflowing when a rain event is more than moderate. Another concern is the energy consumed by wastewater treatment; this problem has become important from the viewpoint of reducing CO(2) emissions and overall costs. Therefore, while establishing a prediction technology for the inflow water quality characteristics of a sewage disposal plant is an important priority, the development of a management/control method for an effluent treatment system that minimises energy consumption and CO(2) emissions due to water disposal is also a pressing research topic with regards to the quality of treated water. The procedure to improve water quality must make use of not only water quality and biotic criteria, but also

  12. NORTH PORTAL - SANITARY SEWER CALCULATION - CHANGE HOUSE FACILITY No.5008

    International Nuclear Information System (INIS)

    Blackstone, R.

    1996-01-01

    The purpose of this design calculation is to determine the demand on the waste system and to size the three main sanitary sewer lines serving the Change House Facility No.5008, in accordance with the Uniform Plumbing Code (Section 4.4.1) and U.S. Department of Energy Order 6430.1A-1540 (Section 4.4.2)

  13. A review of the Y-12 Plant discharge of enriched uranium to the sanitary sewer (DEUSS)

    International Nuclear Information System (INIS)

    1991-09-01

    The Oak Ridge Y-12 Plant is situated adjacent to the Oak Ridge city limits and is operated by the United States Department of Energy (DOE). The Y-12 Plant is located on 4,860 acres, which is collectively referred to as the Y-12 Plant site. Among the missions for which the facility is in existence are producing nuclear weapons components, supporting weapon design laboratories, and processing special nuclear materials (SNM). The Y-12 Plant is under the regulatory guidance of DOE Order 5400.5 and has complied with the technical requirements governing SNM since its issue. However, an in-depth review with appropriate documentation had not been performed, prior to the effect presented herein, to substantiate this claim. As a result of the solid waste issue, it was determined that other types of waste should be formally reviewed for content with respect to SNM. Therefore, a project was formed to investigate the conveyance of SNM through the sanitary sewer system. It is emphasized that this project addresses only effluent from the sanitary sewer system and not the storm sewer system. The project reviewed sanitary sewer data both for the Y-12 Plant and the Y-12 Plant site

  14. A review of the Y-12 Plant discharge of enriched uranium to the sanitary sewer (DEUSS)

    Energy Technology Data Exchange (ETDEWEB)

    1991-09-01

    The Oak Ridge Y-12 Plant is situated adjacent to the Oak Ridge city limits and is operated by the United States Department of Energy (DOE). The Y-12 Plant is located on 4,860 acres, which is collectively referred to as the Y-12 Plant site. Among the missions for which the facility is in existence are producing nuclear weapons components, supporting weapon design laboratories, and processing special nuclear materials (SNM). The Y-12 Plant is under the regulatory guidance of DOE Order 5400.5 and has complied with the technical requirements governing SNM since its issue. However, an in-depth review with appropriate documentation had not been performed, prior to the effect presented herein, to substantiate this claim. As a result of the solid waste issue, it was determined that other types of waste should be formally reviewed for content with respect to SNM. Therefore, a project was formed to investigate the conveyance of SNM through the sanitary sewer system. It is emphasized that this project addresses only effluent from the sanitary sewer system and not the storm sewer system. The project reviewed sanitary sewer data both for the Y-12 Plant and the Y-12 Plant site.

  15. Estimation of Parameters and Flow Characteristics for the Design of Sanitary Sewers in Malaysia

    Directory of Open Access Journals (Sweden)

    Kamran Ansari

    2013-01-01

    Full Text Available Determination of the flow characteristics is very important for the design of sanitary sewers in any area. In the present study these are determined in the running sewers for the two parameters; per capita flow contribution and the peak flow factor. ISCO area - velocity flow meter model 4250 is used for this purpose. The flow meter, before being used in the running sewers, is calibrated first in the Hydraulics and Hydrology Laboratory of the UTM (Universiti Teknologi Malaysia. During the study the flow meter is installed inside the manhole in 10 different phases in the months of June, August, September, and October 2005 to monitor the sewage flow running in it. Continuous data is recorded in the flow meter during the process and the recorded time varies between 47 hours 25 minutes and 128 hours 35 minutes. The rainfall data is also collected during the same time using an automatic rain gauge which recorded rainfall at every five minutes of interval. Both the parameters thus calculated are then compared with the Malaysian Standard for sewer design i.e. MS 1228:1991. The results show that higher values of these parameters are being used in the design of sanitary sewers and extensive study needs to be carried out to review these values for future use

  16. EMISSION OF POLLUTANTS FROM COMBINED SEWER OVERFLOWS IN THE ASPECT OF THEIR IMPACT ON A RECEIVER

    Directory of Open Access Journals (Sweden)

    Agnieszka Brzezińska

    2016-06-01

    Full Text Available Increased efficiency of wastewater treatment highlights the role of combined sewer overflows in deterioration the quality of water receiver because pollutant loads discharged by them have a growing share in entire load discharged into a receiver. The article contains the results of the wastewater quality analyzes emitted into the receiver from the three studied combined sewer overflows of the city of Lodz. The results demonstrated a large variations in the pollutant concentration directed to the receiver during rain events. The possible impact of untreated wastewater emitted to the receiver is also presented. Apart from the pollution of the receiver, mainly by organic and nutrient substances, the microbiological contamination which is dangerous for people using the river as a recreation area and for animals that use a water receiver as a source of drinking water, should be taken into particular attention.

  17. A risk-based approach to sanitary sewer pipe asset management.

    Science.gov (United States)

    Baah, Kelly; Dubey, Brajesh; Harvey, Richard; McBean, Edward

    2015-02-01

    Wastewater collection systems are an important component of proper management of wastewater to prevent environmental and human health implications from mismanagement of anthropogenic waste. Due to aging and inadequate asset management practices, the wastewater collection assets of many cities around the globe are in a state of rapid decline and in need of urgent attention. Risk management is a tool which can help prioritize resources to better manage and rehabilitate wastewater collection systems. In this study, a risk matrix and a weighted sum multi-criteria decision-matrix are used to assess the consequence and risk of sewer pipe failure for a mid-sized city, using ArcGIS. The methodology shows that six percent of the uninspected sewer pipe assets of the case study have a high consequence of failure while four percent of the assets have a high risk of failure and hence provide priorities for inspection. A map incorporating risk of sewer pipe failure and consequence is developed to facilitate future planning, rehabilitation and maintenance programs. The consequence of failure assessment also includes a novel failure impact factor which captures the effect of structurally defective stormwater pipes on the failure assessment. The methodology recommended in this study can serve as a basis for future planning and decision making and has the potential to be universally applied by municipal sewer pipe asset managers globally to effectively manage the sanitary sewer pipe infrastructure within their jurisdiction. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Priority substances in combined sewer overflows: case study of the Paris sewer network.

    Science.gov (United States)

    Gasperi, J; Garnaud, S; Rocher, V; Moilleron, R

    2011-01-01

    This study was undertaken to supply data on both priority pollutant (PP) occurrence and concentrations in combined sewer overflows (CSOs). A single rain event was studied on 13 sites within the Paris sewer network. For each sample, a total of 66 substances, including metals, polycyclic aromatic hydrocarbons (PAHs), pesticides, organotins, volatile organic compounds, chlorobenzenes, phthalates and alkylphenols were analyzed. Of the 66 compounds analyzed in all, 40 PPs including 12 priority hazardous substances were detected in CSOs. As expected, most metals were present in all samples, reflecting their ubiquitous nature. Chlorobenzenes and most pesticides were never quantified above the limit of quantification, while the majority of the other organic pollutants, except DEHP (median concentration: 22 μg.l(-1)), were found to lie in the μg.l(-1) range. For the particular rain event studied, the pollutant loads discharged by CSOs were evaluated and then compared to pollutant loads conveyed by the Seine River. Under the hydraulic conditions considered and according to the estimations performed, this comparison suggests that CSOs are potentially significant local source of metals, PAHs and DEHP. Depending on the substance, the ratio between the CSO and Seine River loads varied from 0.5 to 26, underscoring the important local impact of CSOs at the scale of this storm for most pollutants.

  19. Chemical disinfection of combined sewer overflow waters using performic acid or peracetic acids

    OpenAIRE

    Chhetri, Ravi Kumar; Thornberg, Dines; Berner, Jesper; Gramstad, Robin; Öjstedt, Ulrik; Sharma, Anitha Kumari; Andersen, Henrik Rasmus

    2014-01-01

    We investigated the possibility of applying performic acid (PFA) and peracetic acid (PAA) for disinfection of combined sewer overflow (CSO) in existing CSO management infrastructures. The disinfection power of PFA and PAA towards Escherichia coli (E. coli) and Enterococcus was studied in batch-scale and pre-field experiments. In the batch-scale experiment, 2.5 mg L− 1 PAA removed approximately 4 log unit of E. coli and Enterococcus from CSO with a 360 min contact time. The removal of E. coli ...

  20. Micropollutants in stormwater runoff and combined sewer overflow in the Copenhagen area, Denmark

    DEFF Research Database (Denmark)

    Birch, Heidi; Mikkelsen, Peter Steen; Jensen, J.K.

    2011-01-01

    Stormwater runoff contains a broad range of micropollutants. In Europe a number of these substances are regulated through the Water Framework Directive, which establishes Environmental Quality Standards (EQSs) for surface waters. Knowledge about discharge of these substances through stormwater...... runoff and combined sewer overflows (CSOs) is essential to ensure compliance with the EQSs. Results from a screening campaign including more than 50 substances at four stormwater discharge locations and one CSO in Copenhagen are reported here. Heavy metal concentrations were detected at levels similar...

  1. Geochemical distribution and mobility of heavy metals in sediments of urban streams affected by combined sewer overflows

    Czech Academy of Sciences Publication Activity Database

    Hnaťuková, Petra

    2011-01-01

    Roč. 59, č. 2 (2011), s. 85-94 ISSN 0042-790X R&D Projects: GA AV ČR IAA200600902 Institutional research plan: CEZ:AV0Z20600510 Keywords : sediments * heavy metals * urban streams * sequential extraction * combined sewer overflows Subject RIV: BK - Fluid Dynamics Impact factor: 0.340, year: 2011

  2. Remaining Sites Verification Package for the 1607-F3 Sanitary Sewer System, Waste Site Reclassification Form 2006-047

    Energy Technology Data Exchange (ETDEWEB)

    L. M. Dittmer

    2007-04-26

    The 1607-F3 waste site is the former location of the sanitary sewer system that supported the 182-F Pump Station, the 183-F Water Treatment Plant, and the 151-F Substation. The sanitary sewer system included a septic tank, drain field, and associated pipeline, all in use between 1944 and 1965. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling demonstrated that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also showed that residual contaminant concentrations are protective of groundwater and the Columbia River.

  3. USEPA CAPSTONE REPORT: CONTROL AND TREATMENT

    Science.gov (United States)

    Combined-sewer overflows (CSOs), sanitary-sewer overflows and stormwater (SW) are significant contributors of contamination to surface waters. During a rain event, the flow in a combined sewer system may exceed the capacity of the intercepting sewer leading to the wastewater trea...

  4. Use long short-term memory to enhance Internet of Things for combined sewer overflow monitoring

    Science.gov (United States)

    Zhang, Duo; Lindholm, Geir; Ratnaweera, Harsha

    2018-01-01

    Combined sewer overflow causes severe water pollution, urban flooding and reduced treatment plant efficiency. Understanding the behavior of CSO structures is vital for urban flooding prevention and overflow control. Neural networks have been extensively applied in water resource related fields. In this study, we collect data from an Internet of Things monitoring CSO structure and build different neural network models for simulating and predicting the water level of the CSO structure. Through a comparison of four different neural networks, namely multilayer perceptron (MLP), wavelet neural network (WNN), long short-term memory (LSTM) and gated recurrent unit (GRU), the LSTM and GRU present superior capabilities for multi-step-ahead time series prediction. Furthermore, GRU achieves prediction performances similar to LSTM with a quicker learning curve.

  5. Update summary of the 1991 discharge of enriched uranium to the sanitary sewer (DEUSS) report

    International Nuclear Information System (INIS)

    1995-04-01

    Since the 1991 Y-12 Plant report, a flow study of the Y-12 Plant sanitary sewer collection system has been completed by the Y-12 Plant staff (Hanzelka and Maguire, 1993). Additional data has been obtained by the Y-12 Plant and the City of Oak Ridge (COR, 1994). COR developed limits on radionuclide concentrations in sludges used for land application (Stetar, 1993). Martin Marietta Energy Systems has provided recommendations to the Department of Energy (DOE) regarding the impacts of sludge land farming operations on the ORR (Frye, 1992). The DOE Office of Nuclear Safety (USDOE, 1993) completed an audit of activities related to radiological contamination of the COR sewer system due to DOE operations. In addition COR is currently developing limits on radionuclide releases for all industrial customers to be applied through the permitting process. In 1994, a new sanitary sewer monitoring station was installed and began operation at the Y-12 Plant to determine releases specifically from the Y-12 Plant. Previously, estimates were based on mass balance calculations using data from the City Monitoring Station which monitors Union Valley and Y-12 Plant releases. The purpose of this report is to update the 1991 Y-12 Plant study taking into account current data and information

  6. Evaluating rain gardens as a method to reduce the impact of sewer overflows in sources of drinking water.

    Science.gov (United States)

    Autixier, Laurène; Mailhot, Alain; Bolduc, Samuel; Madoux-Humery, Anne-Sophie; Galarneau, Martine; Prévost, Michèle; Dorner, Sarah

    2014-11-15

    The implications of climate change and changing precipitation patterns need to be investigated to evaluate mitigation measures for source water protection. Potential solutions need first to be evaluated under present climate conditions to determine their utility as climate change adaptation strategies. An urban drainage network receiving both stormwater and wastewater was studied to evaluate potential solutions to reduce the impact of combined sewer overflows (CSOs) in a drinking water source. A detailed hydraulic model was applied to the drainage basin to model the implementation of best management practices at a drainage basin scale. The model was calibrated and validated with field data of CSO flows for seven events from a survey conducted in 2009 and 2010. Rain gardens were evaluated for their reduction of volumes of water entering the drainage network and of CSOs. Scenarios with different levels of implementation were considered and evaluated. Of the total impervious area within the basin directly connected to the sewer system, a maximum of 21% could be alternately directed towards rain gardens. The runoff reductions for the entire catchment ranged from 12.7% to 19.4% depending on the event considered. The maximum discharged volume reduction ranged from 13% to 62% and the maximum peak flow rate reduction ranged from 7% to 56%. Of concern is that in-sewer sediment resuspension is an important process to consider with regard to the efficacy of best management practices aimed at reducing extreme loads and concentrations. Rain gardens were less effective for large events, which are of greater importance for drinking water sources. These practices could increase peak instantaneous loads as a result of greater in-sewer resuspension during large events. Multiple interventions would be required to achieve the objectives of reducing the number, total volumes and peak contaminant loads of overflows upstream of drinking water intakes. Copyright © 2014 Elsevier B.V. All

  7. Climate change impacts on the duration and frequency of combined sewer overflows

    Science.gov (United States)

    Fortier, C.; Mailhot, A.

    2012-12-01

    Combined sewer overflows (CSO) occur when large rainwater inflow from heavy precipitation exceeds the capacity of urban combined sewage systems. Many American and European cities with old sewage systems see their water quality significantly deteriorate during such events. In the long term, changes in the rainfall regime due to climate change may lead to more severe and more frequent CSO episodes and thus compel cities to review their global water management. The overall objective of this study is to investigate how climate change will impact CSO frequency and duration. Data from rain gauges located nearby 30 overflow outfalls, in southern Quebec, Canada, were used to identify rain events leading to overflows, using CSO monitored data from May to October during the period 2007-2009. For each site, occurrence and duration of CSO events were recorded and linked to a rainfall event. Many rain events features can be used to predict CSO events, such as total depth, duration, average intensity and peak intensity. Results based on Pearson product-moment correlation coefficients and multiple regression analysis show that CSO occurrence is best predicted by total rainfall. A methodology is proposed to calculate the CSO probability of occurrence and duration for each site of interest using rainfall series as input data. Monte Carlo method is then used to estimate CSO frequency. To evaluate the climate change impact on CSO, these relationships are used with simulated data from the Canadian Regional Climate Model to compare the distribution of annual number of CSO events over the 1960-1990 period and the 2070-2100 period.

  8. Water quality control of combined sewer overflows. The <> procedure; Il controllo qualitativo delle immissioni fognarie nei corpi idrici. La procedura <>

    Energy Technology Data Exchange (ETDEWEB)

    Artina, S.; Maglionico, M. [Bologna Univ., Bologna (Italy). Dipt. di Ingegneria delle Strutture, dei Trasporti, delle Acque, del Rilevamento, del Territorio; Lo Greco, P. [HR Wallingford, Wallingford Oxfordshire (United Kingdom)

    2000-05-01

    The EEC Directive 91/271 endorse has brought to attention the pollution problem caused in the receiving waters by Combined Sewer Overflows (CSOs). This paper describes a procedure, set up in England, called UPM (Urban Pollution Management), meant to environmentally protect receiving waters. The UPM Procedure is merely a methodology to evaluate the impact of pollutants discharged from sewer overflows during rainfall events. [Italian] Il recepimento della direttiva CEE 91/271 ha portato ancora una volta in primo piano il problema dell'inquinamento dei corpi idrici causato dalle immissioni fognarie. Il presente articolo descrive una procedura messa a punto in Inghilterra, denominata UPM (Urban Pollution Management), destinata al controllo qualitativo dei corsi d'acqua ricettori di scarichi fognari. L'UPM non costituisce una normativa bensi una metodologia intesa a valutare l'impatto degli scarichi fognari sui ricettori durante gli eenti meteorici.

  9. An effective and comprehensive model for optimal rehabilitation of separate sanitary sewer systems.

    Science.gov (United States)

    Diogo, António Freire; Barros, Luís Tiago; Santos, Joana; Temido, Jorge Santos

    2018-01-15

    In the field of rehabilitation of separate sanitary sewer systems, a large number of technical, environmental, and economic aspects are often relevant in the decision-making process, which may be modelled as a multi-objective optimization problem. Examples are those related with the operation and assessment of networks, optimization of structural, hydraulic, sanitary, and environmental performance, rehabilitation programmes, and execution works. In particular, the cost of investment, operation and maintenance needed to reduce or eliminate Infiltration from the underground water table and Inflows of storm water surface runoff (I/I) using rehabilitation techniques or related methods can be significantly lower than the cost of transporting and treating these flows throughout the lifespan of the systems or period studied. This paper presents a comprehensive I/I cost-benefit approach for rehabilitation that explicitly considers all elements of the systems and shows how the approximation is incorporated as an objective function in a general evolutionary multi-objective optimization model. It takes into account network performance and wastewater treatment costs, average values of several input variables, and rates that can reflect the adoption of different predictable or limiting scenarios. The approach can be used as a practical and fast tool to support decision-making in sewer network rehabilitation in any phase of a project. The fundamental aspects, modelling, implementation details and preliminary results of a two-objective optimization rehabilitation model using a genetic algorithm, with a second objective function related to the structural condition of the network and the service failure risk, are presented. The basic approach is applied to three real world cases studies of sanitary sewerage systems in Coimbra and the results show the simplicity, suitability, effectiveness, and usefulness of the approximation implemented and of the objective function proposed

  10. 76 FR 49505 - Notice of Lodging of a Consent Decree Under the Clean Water Act

    Science.gov (United States)

    2011-08-10

    ... District's (``MSD's'') operation of its sewer system in the City of St. Louis and St. Louis County, Missouri. The Complaint alleged that MSD's discharges of raw sewage from its sanitary sewer system-- discharges that often are referred to as Sanitary Sewer Overflows or ``SSOs''--and from MSD's combined storm...

  11. [Study on the characteristics of combined sewer overflow from the high density residential area in Shanghai].

    Science.gov (United States)

    Li, He; Li, Tian

    2006-08-01

    The urban non-point pollution has become main pollution resource of urban water bodies of Shanghai. Character of combined sewer overflow from watershed SA in Shanghai was studied, and the correlation of influence factors to the EMCs of overflows was discussed. It is found that the EMCs of COD, BOD, SS, NH3-N, TN, TP are 614 mg/L, 208.5 mg/L, 684 mg/L, 17.6 mg/L, 29.8 mg/L, 3.0 mg/L respectively, and the values obtained herein are much higher than the documented data from other countries. From the probability plot of the EMCs, it is found that the BOD has the best fitness for lognormal distribution; and correlation between the EMCs of COD, SS and the ratio of antecedent dry weather time to rain duration is quite good.

  12. ICUD-0530 Scenario based risk assessment of the dispersion of E-coli from combined sewer overflow to a fresh-water lake

    DEFF Research Database (Denmark)

    Rasmussen, Michael Robdrup; Thorndahl, Søren Liedtke; Nielsen, Jesper Ellerbæk

    2017-01-01

    A scenario based risk assessment method is used to evaluate how combined sewer overflow (CSO) affects a nearby bathing beach in Skanderborg, Denmark. The method combines an urban drainage model with a 3D CFD model to pre-simulate 60 different scenarios, used for assessing the risk of poor bathing...

  13. Predicting combined sewer overflows chamber depth using artificial neural networks with rainfall radar data.

    Science.gov (United States)

    Mounce, S R; Shepherd, W; Sailor, G; Shucksmith, J; Saul, A J

    2014-01-01

    Combined sewer overflows (CSOs) represent a common feature in combined urban drainage systems and are used to discharge excess water to the environment during heavy storms. To better understand the performance of CSOs, the UK water industry has installed a large number of monitoring systems that provide data for these assets. This paper presents research into the prediction of the hydraulic performance of CSOs using artificial neural networks (ANN) as an alternative to hydraulic models. Previous work has explored using an ANN model for the prediction of chamber depth using time series for depth and rain gauge data. Rainfall intensity data that can be provided by rainfall radar devices can be used to improve on this approach. Results are presented using real data from a CSO for a catchment in the North of England, UK. An ANN model trained with the pseudo-inverse rule was shown to be capable of predicting CSO depth with less than 5% error for predictions more than 1 hour ahead for unseen data. Such predictive approaches are important to the future management of combined sewer systems.

  14. Remaining Sites Verification Package for the 100-F-26:10, 1607-F3 Sanitary Sewer Pipelines (182-F, 183-F, and 151-F Sanitary Sewer Lines), Waste Site Reclassification Form 2007-028

    Energy Technology Data Exchange (ETDEWEB)

    L. M. Dittmer

    2007-12-03

    The 100-F-26:10 waste site includes sanitary sewer lines that serviced the former 182-F, 183-F, and 151-F Buildings. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

  15. Combined sewer overflows: an environmental source of hormones and wastewater micropollutants

    Science.gov (United States)

    Phillips, P.J.; Chalmers, A.T.; Gray, J.L.; Kolpin, D.W.; Foreman, W.T.; Wall, G.R.

    2012-01-01

    Data were collected at a wastewater treatment plant (WWTP) in Burlington, Vermont, USA, (serving 30,000 people) to assess the relative contribution of CSO (combined sewer overflow) bypass flows and treated wastewater effluent to the load of steroid hormones and other wastewater micropollutants (WMPs) from a WWTP to a lake. Flow-weighted composite samples were collected over a 13 month period at this WWTP from CSO bypass flows or plant influent flows (n = 28) and treated effluent discharges (n = 22). Although CSO discharges represent 10% of the total annual water discharge (CSO plus treated plant effluent discharges) from the WWTP, CSO discharges contribute 40–90% of the annual load for hormones and WMPs with high (>90%) wastewater treatment removal efficiency. By contrast, compounds with low removal efficiencies (hormones and many WMPs in samples from treated discharges can increase with increasing flow due to decreasing removal efficiency.

  16. Combined Sewer Overflow pretreatment with chemical coagulation and a particle settler for improved peracetic acid disinfection

    DEFF Research Database (Denmark)

    Chhetri, Ravi Kumar; Bonnerup, Arne; Andersen, Henrik Rasmus

    2016-01-01

    Full scale disinfection by peracetic acid (PAA) was achieved on Combined Sewer Overflow (CSO) water, which was pre-treated physically by a fast settling-filtration unit. Disinfection of untreated CSO water using PAA was compared to treatment using a particle separator (Hydro......Separator®) and additional coagulation with poly-aluminum-chloride. Disinfection for Enterococcus increased with the applied dose of PAA and additional improvement was achieved when it was preceded by chemical coagulation with 5 mg L−1 poly-aluminum-chloride. When Enterococcus was reduced by treatment in the Hydro...

  17. Separate and combined sewer systems: a long-term modelling approach.

    Science.gov (United States)

    Mannina, Giorgio; Viviani, Gaspare

    2009-01-01

    Sewer systems convey mostly dry weather flow, coming from domestic and industrial sanitary sewage as well as infiltration flow, and stormwater due to meteoric precipitations. Traditionally, in urban drainage two types of sewer systems are adopted: separate and combined sewers. The former convey dry and wet weather flow separately into two different networks, while the latter convey dry and wet weather flow together. Which is the best solution in terms of cost-benefit analysis still remains a controversial subject. The present study was aimed at comparing the pollution loads discharged to receiving bodies by Wastewater Treatment Plant (WWTP) and Combined Sewer Overflow (CSO) for different kinds of sewer systems (combined and separate). To accomplish this objective, a comparison between the two systems was carried out using results from simulations of catchments characterised by different dimensions, population densities and water supply rate. The analysis was based on a parsimonious mathematical model able to simulate the sewer system as well as the WWTP during both dry and wet weather. The rain series employed for the simulations was six years long. Several pollutants, both dissolved and particulate, were modelled. The results confirmed the uncertainties in the choice of one system versus the other, emphasising the concept that case-by-case solutions have to be undertaken. Further, the compared systems showed different responses in terms of effectiveness in reducing the discharged mass to the RWB in relation to the particular pollutant taken into account.

  18. Urban sewershed overflow analysis using super-resolution weather radar rainfall

    OpenAIRE

    Hyun, J. Y.; Rockaway, T. D.; French, M. N.

    2016-01-01

    In urban areas, a prevalence of combined sewer systems (CSS) exist that carry both storm water runoff and sanitary sewer flows in a single pipe, these system are considered combined sewers. In the absence of rainfall-runoff most of these systems function adequately, however CSS capacity is typically inadequate to carry peak stormwater runoff volume. In order to minimize sewage flooding into streets and backups into homes and businesses, most CSS (as well as separate sanitary sewer system) are...

  19. Estimation of combined sewer overflow discharge: a software sensor approach based on local water level measurements.

    Science.gov (United States)

    Ahm, Malte; Thorndahl, Søren; Nielsen, Jesper E; Rasmussen, Michael R

    2016-12-01

    Combined sewer overflow (CSO) structures are constructed to effectively discharge excess water during heavy rainfall, to protect the urban drainage system from hydraulic overload. Consequently, most CSO structures are not constructed according to basic hydraulic principles for ideal measurement weirs. It can, therefore, be a challenge to quantify the discharges from CSOs. Quantification of CSO discharges are important in relation to the increased environmental awareness of the receiving water bodies. Furthermore, CSO discharge quantification is essential for closing the rainfall-runoff mass-balance in combined sewer catchments. A closed mass-balance is an advantage for calibration of all urban drainage models based on mass-balance principles. This study presents three different software sensor concepts based on local water level sensors, which can be used to estimate CSO discharge volumes from hydraulic complex CSO structures. The three concepts were tested and verified under real practical conditions. All three concepts were accurate when compared to electromagnetic flow measurements.

  20. Dynamics of rain-induced pollutographs of solubles in sewers.

    Science.gov (United States)

    Rutsch, M; Müller, I; Krebs, P

    2005-01-01

    When looking at acute receiving water impacts due to combined sewer overflows the characteristics of the background diurnal sewage flux variation may influence the peak loads from combined sewer overflows (CSO) and wastewater treatment plant (WWTP) effluent significantly. In this paper, effects on the dynamic compounds transported in the sewer, on CSO discharges and WWTP loading are evaluated by means of hydrodynamic simulations. The simulations are based on different scenarios for diurnal dry-weather flow variations induced by different infiltration rates.

  1. Toxicity and pollutant impact analysis in an urban river due to combined sewer overflows loads.

    Science.gov (United States)

    Casadio, A; Maglionico, M; Bolognesi, A; Artina, S

    2010-01-01

    The Navile Channel (Bologna, Italy) is an ancient artificial water course derived from the Reno river. It is the main receiving water body for the urban catchment of Bologna sewer systems and also for the Waste Water Treatment Plant (WWTP) main outlet. The aim of this work is to evaluate the Combined Sewer Overflows (CSOs) impact on Navile Channel's water quality. In order to collect Navile flow and water quality data in both dry and wet weather conditions, two measuring and sampling stations were installed, right upstream and downstream the WWTP outflow. The study shows that even in case of low intensity rain events, CSOs have a significant effect on both water quantity and quality, spilling a considerable amount of pollutants into the Navile Channel and presenting also acute toxicity effects. The collected data shown a good correlations between the concentrations of TSS and of chemical compounds analyzed, suggesting that the most part of such substances is attached to suspended solids. Resulting toxicity values are fairly high in both measuring points and seem to confirm synergistic interactions between heavy metals.

  2. Coupled 1D-2D hydrodynamic inundation model for sewer overflow: Influence of modeling parameters

    Directory of Open Access Journals (Sweden)

    Adeniyi Ganiyu Adeogun

    2015-10-01

    Full Text Available This paper presents outcome of our investigation on the influence of modeling parameters on 1D-2D hydrodynamic inundation model for sewer overflow, developed through coupling of an existing 1D sewer network model (SWMM and 2D inundation model (BREZO. The 1D-2D hydrodynamic model was developed for the purpose of examining flood incidence due to surcharged water on overland surface. The investigation was carried out by performing sensitivity analysis on the developed model. For the sensitivity analysis, modeling parameters, such as mesh resolution Digital Elevation Model (DEM resolution and roughness were considered. The outcome of the study shows the model is sensitive to changes in these parameters. The performance of the model is significantly influenced, by the Manning's friction value, the DEM resolution and the area of the triangular mesh. Also, changes in the aforementioned modeling parameters influence the Flood characteristics, such as the inundation extent, the flow depth and the velocity across the model domain. Keywords: Inundation, DEM, Sensitivity analysis, Model coupling, Flooding

  3. Combined sewer overflow control with LID based on SWMM: an example in Shanghai, China.

    Science.gov (United States)

    Liao, Z L; Zhang, G Q; Wu, Z H; He, Y; Chen, H

    2015-01-01

    Although low impact development (LID) has been commonly applied across the developed countries for mitigating the negative impacts of combined sewer overflows (CSOs) on urban hydrological environment, it has not been widely used in developing countries yet. In this paper, a typical combined sewer system in an urbanized area of Shanghai, China was used to demonstrate how to design and choose CSO control solutions with LID using stormwater management model. We constructed and simulated three types of CSO control scenarios. Our findings support the notion that LID measures possess favorable capability on CSO reduction. Nevertheless, the green scenarios which are completely comprised by LID measures fail to achieve the maximal effectiveness on CSO reduction, while the gray-green scenarios (LID measure combined with gray measures) achieve it. The unit cost-effectiveness of each type of scenario sorts as: green scenario > gray-green scenario > gray scenario. Actually, as the storage tank is built in the case catchment, a complete application of green scenario is inaccessible here. Through comprehensive evaluation and comparison, the gray-green scenario F which used the combination of storage tank, bio-retention and rain barrels is considered as the most feasible one in this case.

  4. FLUSHING FOR SEWER SEDIMENT, CORROSION, AND POLLUTION CONTROL

    Science.gov (United States)

    This presentation overviews causes of sewer deterioration and heavy pollutant discharges caused by rain events together with a discussion of their control methods. In particular, it covers in-sewer- and combined sewer overflow- (CSO-) storage-tank-flushing systems for removal of ...

  5. Remaining Sites Verification Package for the 100-F-26:10, 1607-F3 Sanitary Sewer Pipelines (182-F, 183-F, and 151-F Sanitary Sewer Lines). Attachment to Waste Site Reclassification Form 2007-028

    International Nuclear Information System (INIS)

    Dittmer, L.M.

    2007-01-01

    The 100-F-26:10 waste site includes sanitary sewer lines that serviced the former 182-F, 183-F, and 151-F Buildings. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River

  6. FLUSHING FOR SEWER SEDIMENT, CORROSION, AND POLLUTION CONTROL

    Science.gov (United States)

    This paper overviews causes of combined-sewer deterioration and their heavy pollutant discharges caused by rain events together with a discussion of their control methods. In particular, it covers in-sewer and combined-sewer overflow (CSO) storage-tank-flushing systems for removi...

  7. Real Rainfall Time Series for Storm Sewer Design

    DEFF Research Database (Denmark)

    Larsen, Torben

    The paper describes a simulation method for the design of retention storages, overflows etc. in storm sewer systems. The method is based on computer simulation with real rainfall time series as input ans with the aply of a simple transfer model of the ARMA-type (autoregressiv moving average model......) as the model of the storm sewer system. The output of the simulation is the frequency distribution of the peak flow, overflow volume etc. from the overflow or retention storage. The parameters in the transfer model is found either from rainfall/runoff measurements in the catchment or from one or a few...

  8. Mechanisms of fat, oil and grease (FOG) deposit formation in sewer lines.

    Science.gov (United States)

    He, Xia; de los Reyes, Francis L; Leming, Michael L; Dean, Lisa O; Lappi, Simon E; Ducoste, Joel J

    2013-09-01

    FOG deposits in sewer systems have recently been shown to be metallic salts of fatty acids. However, the fate and transport of FOG deposit reactant constituents and the complex interactions during the FOG deposit formation process are still largely unknown. In this study, batch tests were performed to elucidate the mechanisms of FOG deposit formation that lead to sanitary sewer overflows (SSOs). We report the first formation of FOG deposits on a concrete surface under laboratory conditions that mimic the formation of deposits in sewer systems. Results showed that calcium, the dominant metal in FOG deposits, can be released from concrete surfaces under low pH conditions and contribute to the formation process. Small amounts of additional oil to grease interceptor effluent substantially facilitated the air/water or pipe surface/water interfacial reaction between free fatty acids and calcium to produce surface FOG deposits. Tests of different fatty acids revealed that more viscous FOG deposit solids were formed on concrete surfaces, and concrete corrosion was accelerated, in the presence of unsaturated FFAs versus saturated FFAs. Based on all the data, a comprehensive model was proposed for the mechanisms of FOG deposit formation in sewer systems. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Factors that influence properties of FOG deposits and their formation in sewer collection systems.

    Science.gov (United States)

    Iasmin, Mahbuba; Dean, Lisa O; Lappi, Simon E; Ducoste, Joel J

    2014-02-01

    Understanding the formation of Fat, Oil, and Grease (FOG) deposits in sewer systems is critical to the sustainability of sewer collection systems since they have been implicated in causing sewerage blockages that leads to sanitary sewer overflows (SSOs). Recently, FOG deposits in sewer systems displayed strong similarities with calcium-based fatty acid salts as a result of a saponification reaction. The objective of this study was to quantify the factors that may affect the formation of FOG deposits and their chemical and rheological properties. These factors included the types of fats used in FSEs, environmental conditions (i.e. pH and temperature), and the source of calcium in sewer systems. The results of this study showed that calcium content in the calcium based salts seemed to depend on the solubility limit of the calcium source and influenced by pH and temperature conditions. The fatty acid profile of the calcium-based fatty acid salts produced under alkali driven hydrolysis were identical to the profile of the fat source and did not match the profile of field FOG deposits, which displayed a high fraction of palmitic, a long chain saturated fatty acid. It is hypothesized that selective microbial metabolism of fats and/or biologically induced hydrogenation may contribute to the FOG deposit makeup in sewer system. Therefore, selective removal of palmitic in pretreatment processes may be necessary prior to the discharge of FSE wastes into the sewer collection system. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. On Hydraulic and Pollution Effects of Converting Combined Sewer Catchments to Separate Sewer Catchments

    DEFF Research Database (Denmark)

    Thorndahl, Søren Liedtke; Schaarup-Jensen, Kjeld; Rasmussen, Michael R.

    2015-01-01

    systems to become serviced with separate sewer systems decreases the volumes of storm water and pollutants diverted to the waste water treatment plant and discharged as combined sewer overflow. This happens at the expense of an increase in volumes of storm water and pollutant loads diverted to local...... receiving waters when detention ponds are not built-in the new separate sewer systems. It is concluded that consequences can be fatal for receiving waters, if no retention of pollutants is integrated into the system....

  11. Temporal analysis of E. coli, TSS and wastewater micropollutant loads from combined sewer overflows: implications for management.

    Science.gov (United States)

    Anne-Sophie, Madoux-Humery; Dorner, Sarah M; Sauvé, Sébastien; Aboulfadl, Khadija; Galarneau, Martine; Servais, Pierre; Prévost, Michèle

    2015-05-01

    A combined sewer overflow (CSO) outfall was monitored to assess the impact of temporal mass loads on the appropriateness of treatment options. Instantaneous loads (mass per s) varied by approximately three orders of magnitude during events (n = 9 in spring, summer and the fall) with no significant seasonal variations. The median fraction of total loads discharged with the first 25% of the total volume ranged from 28% (theophylline) to 40% (Total Suspended Solids (TSS)) and loads remained high for the duration of the events. E. coli and TSS loads originated primarily from wastewater (WW) (63% and 75%, respectively). However, a mix of stormwater (SW) and sewer deposit (SD) resuspension contributed from 73 to 95% for the first 50% of the volume discharged of total TSS loads for 2 events. The contribution of SD resuspension was not negligible for Wastewater Micropollutants (WWMPs), especially for carbamazepine. Sustained high loads over the course of CSOs highlight the need to revisit current CSO and SW management strategies that focus on the treatment of early discharge volumes.

  12. Contributions of combined sewer overflows and treated effluents to the bacterial load released into a coastal area.

    Science.gov (United States)

    Al Aukidy, M; Verlicchi, P

    2017-12-31

    The impact of combined sewer overflow (CSO) on the receiving water body is an issue of increasing concern, as it may lead to restrictions in the use and destination of the receiving body, such as bathing or recreational area closures, fish and shellfish consumption restrictions, and contamination of drinking water resources. Recent investigations have mainly referred to the occurrence and loads of suspended solids, organic compounds and, in some cases, micropollutants. Attempts have been made to find correlations between the discharged load and the size and characteristics of the catchment area, climate conditions, rainfall duration and intensity. This study refers to a touristic coastal area in the north-east of Italy, which is characterized by a combined sewer network including 5 CSO outfalls which, in the case of heavy rain events, directly discharge the exceeding water flow rate into channels which, after a short distance, reach the Adriatic Sea. The study analyzed: i) rainfall events during the summer period in 2014 which led to overflow in the different outfalls, ii) the inter- and intra-event variability with regard to E. coli, Enterococci and conductivity, and iii) the hydraulic and pollutant (E. coli and Enterococci) loads discharged by the local wastewater treatment plant and by all the CSO outfalls. Finally, it estimated the contribution of each source to the released hydraulic and pollutant loads into the receiving water body. Moreover, it was also found that the modest water volume discharged by all CSO outfalls (only 8% of the total volume discharged by the area) contains >90% of the microbial load. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Understanding the spatial formation and accumulation of fats, oils and grease deposits in the sewer collection system.

    Science.gov (United States)

    Dominic, Christopher Cyril Sandeep; Szakasits, Megan; Dean, Lisa O; Ducoste, Joel J

    2013-01-01

    Sanitary sewer overflows are caused by the accumulation of insoluble calcium salts of fatty acids, which are formed by the reaction between fats, oils and grease (FOG) and calcium found in wastewaters. Different sewer structural configurations (i.e., manholes, pipes, wet wells), which vary spatially, along with other obstructions (roots intrusion) and pipe deformations (pipe sags), may influence the detrimental buildup of FOG deposits. The purpose of this study was to quantify the spatial variation in FOG deposit formation and accumulation in a pilot-scale sewer collection system. The pilot system contained straight pipes, manholes, roots intrusion, and a pipe sag. Calcium and oil were injected into the system and operated at alkaline (pH = 10) and neutral (pH = 7) pH conditions. Results showed that solid accumulations were slightly higher at neutral pH. Fourier transform infrared (FTIR) analysis on the solids samples confirmed that the solids were indeed calcium-based fatty acid salts. However, the fatty acid profiles of the solids deviated from the profile found from FOG deposits in sewer systems, which were primarily saturated fatty acids. These results confirm the work done previously by researchers and suggest an alternative fate of unsaturated fatty acids that does not lead to their incorporation in FOG deposits in full-scale sewer systems.

  14. Performance assessment of a vertical flow constructed wetland treating unsettled combined sewer overflow.

    Science.gov (United States)

    Pálfy, T G; Gerodolle, M; Gourdon, R; Meyer, D; Troesch, S; Molle, P

    2017-06-01

    The performance of a vertical flow constructed wetland for combined sewer overflow treatment (CSO CW) has been evaluated. The full-scale site has been monitored for 3 years for major pollutants and for two load events for a range of micropollutants (metals, metalloids and polycyclic aromatic hydrocarbons (PAHs)). Performance were predominantly high (97% for total suspended solids (TSS), 80% for chemical oxygen demand (COD), 72% for NH 4 -N), even if several loads were extremely voluminous, pushing the filter to its limits. Two different filter materials (a 4:1 mixture of sand and zeolite and natural pozzolana) showed similar treatment performance. Furthermore, environmental factors were correlated with COD removal efficiency. The greatest influencers of COD removal efficiency were the inlet dissolved COD concentrations and the duration and potential evapotranspiration during inter-event periods. Furthermore, sludge was analysed for quality and a sludge depth map was created. The map, and calculating the changes in sludge volume, helped to understand solid accumulation dynamics.

  15. Chemical disinfection of combined sewer overflow waters using performic acid or peracetic acids

    DEFF Research Database (Denmark)

    Chhetri, Ravi Kumar; Thornberg, Dines; Berner, Jesper

    2014-01-01

    We investigated the possibility of applying performic acid (PFA) and peracetic acid (PAA) for disinfection of combined sewer overflow (CSO) in existing CSO management infrastructures. The disinfection power of PFA and PAA towards Escherichia coli (E. coli) and Enterococcus was studied in batch......-scale and pre-field experiments. In the batch-scale experiment, 2.5 mg L− 1 PAA removed approximately 4 log unit of E. coli and Enterococcus from CSO with a 360 min contact time. The removal of E. coli and Enterococcus from CSO was always around or above 3 log units using 2–4 mg L− 1 PFA; with a 20 min contact...... time in both batch-scale and pre-field experiments. There was no toxicological effect measured by Vibrio fischeri when CSO was disinfected with PFA; a slight toxic effect was observed on CSO disinfected with PAA. When the design for PFA based disinfection was applied to CSO collected from an authentic...

  16. Evaluation of exposure pathways to man from disposal of radioactive materials into sanitary sewer systems

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, W.E. Jr.; Parkhurst, M.A.; Aaberg, R.L.; Rhoads, K.C.; Hill, R.L.; Martin, J.B. [Pacific Northwest Lab., Richland, WA (United States)

    1992-05-01

    In accordance with 10 CFR 20, the US Nuclear Regulatory Commission (NRC) regulates licensees` discharges of small quantities of radioactive materials into sanitary sewer systems. This generic study was initiated to examine the potential radiological hazard to the public resulting from exposure to radionuclides in sewage sludge during its treatment and disposal. Eleven scenarios were developed to characterize potential exposures to radioactive materials during sewer system operations and sewage sludge treatment and disposal activities and during the extended time frame following sewage sludge disposal. Two sets of deterministic dose calculations were performed; one to evaluate potential doses based on the radionuclides and quantities associated with documented case histories of sewer system contamination and a second, somewhat more conservative set, based on theoretical discharges at the maximum allowable levels for a more comprehensive list of 63 radionuclides. The results of the stochastic uncertainty and sensitivity analysis were also used to develop a collective dose estimate. The collective doses for the various radionuclides and scenarios range from 0.4 person-rem for {sup 137}Cs in Scenario No. 5 (sludge incinerator effluent) to 420 person-rem for {sup 137}Cs in Scenario No. 3 (sewage treatment plant liquid effluent). None of the 22 scenario/radionuclide combinations considered have collective doses greater than 1000 person-rem/yr. However, the total collective dose from these 22 combinations was found to be about 2100 person-rem.

  17. Evaluation of exposure pathways to man from disposal of radioactive materials into sanitary sewer systems

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Parkhurst, M.A.; Aaberg, R.L.; Rhoads, K.C.; Hill, R.L.; Martin, J.B.

    1992-05-01

    In accordance with 10 CFR 20, the US Nuclear Regulatory Commission (NRC) regulates licensees' discharges of small quantities of radioactive materials into sanitary sewer systems. This generic study was initiated to examine the potential radiological hazard to the public resulting from exposure to radionuclides in sewage sludge during its treatment and disposal. Eleven scenarios were developed to characterize potential exposures to radioactive materials during sewer system operations and sewage sludge treatment and disposal activities and during the extended time frame following sewage sludge disposal. Two sets of deterministic dose calculations were performed; one to evaluate potential doses based on the radionuclides and quantities associated with documented case histories of sewer system contamination and a second, somewhat more conservative set, based on theoretical discharges at the maximum allowable levels for a more comprehensive list of 63 radionuclides. The results of the stochastic uncertainty and sensitivity analysis were also used to develop a collective dose estimate. The collective doses for the various radionuclides and scenarios range from 0.4 person-rem for 137 Cs in Scenario No. 5 (sludge incinerator effluent) to 420 person-rem for 137 Cs in Scenario No. 3 (sewage treatment plant liquid effluent). None of the 22 scenario/radionuclide combinations considered have collective doses greater than 1000 person-rem/yr. However, the total collective dose from these 22 combinations was found to be about 2100 person-rem

  18. Reconcentration of radioactive material released to sanitary sewers in accordance with 10 CFR Part 20

    International Nuclear Information System (INIS)

    Ainsworth, C.C.; Hill, R.L.; Cantrell, K.J.; Kaplan, D.I.; Norton, M.V.; Aaberg, R.L.; Stetar, E.A.

    1994-12-01

    The US Nuclear Regulatory Commission (NRC), in accordance with 10 CFR 20, and agreement states, in accordance with state regulations, regulates the discharge of radioactive materials into sanitary sewer systems. A one-year study was conducted by Pacific Northwest Laboratory (PNL) for the NRC to assess whether radioactive materials that are dischared to sanitary sewer systems undergo significant reconcentration within the wastewater treatment plants (WWTP) and to determine the physical and/or chemical processes that may result in radionuclide reconcentration within the WWTPs. The study objectives were addressed by collecting information and data on wastewater treatment, relevant geochemical processes, and individual radionuclide behavior in WWTPs from the open literature, NRC reports, EPA surveys, and interviews with NRC licensees and staff of WWTPs that may be impacted by these discharges. Radionuclide mass balance and removal efficiencies were calculated for WWTPs at Oak Ridge, TN; and Erwin, TN, but were not shown to be reliable since the licensee release data generally underestimated the mass of radionuclide that was ultimately found in the sludge. This disparity may be due, in part, to the fact that data available for use in this study were collected to address regulatory concerns and not to perform mass balance calculations. A limited modeling study showed some promise for predicting radionuclide behavior in WWTPS, however, the general applicability of using these empirical models remains uncertain. With the data and models currently available, it is not possible to quantitatively determine the physical and chemical processes that cause reconcentration or to calculate, a priori, reconcentration factors for specific WWTP unit processes or WWTPs in general

  19. Impact of Combined Sewer Overflow on Wastewater Treatment and Microbiological Quality of Rivers for Recreation

    Directory of Open Access Journals (Sweden)

    Franz Mascher

    2017-11-01

    Full Text Available Within the framework of a one-year study the treatment capacity of a municipal wastewater treatment plant (WWTP was evaluated, with regard to fecal indicator bacteria (FIB and to their influence on the recipient. The logarithmic reduction rates for fecal coliforms (FC, Escherichia coli (EC and intestinal enterococci (IE were 2.84, 2.90 and 2.93. In the investigated period of time, the tested treatment plant released 4.3% of the total annual load flow volume as combined sewer overflow (CSO, that is, when the influent into the combined sewer exceeds the capacity of the treatment plant and coarsely cleaned wastewater arrives at the recipient. This CSO discharge increased the number of FIB significantly by 1.2 × 102 MPN/100 mL for EC, and by 1.8 × 101 MPN/100 mL for IE. For the Styrian part of the Mur River (1.6 million inhabitants, a calculation of FIB of all sewage treatment plants estimating the same ratio of CSO (4.3% and a given mean flow rate (QM results in a significant increase of the FIB load in the recipient: 3.8 × 103 MPN/100 mL for EC and 5.8 × 102 MPN/100 mL for IE. On the basis of these values the standards of water quality for recreational purposes cannot be met.

  20. Real Rainfall Time Series for Storm Sewer Design

    DEFF Research Database (Denmark)

    Larsen, Torben

    1981-01-01

    to a storm sewer system. The output of the simulation is the frequency distribution of the peak flow, overflow volume etc. from the overflow or the retention storage. The parameters in the transfer model are found either from rainfall/runoff measurements in the catchment or from one or more simulations...

  1. Removal of micropollutants, facultative pathogenic and antibiotic resistant bacteria in a full-scale retention soil filter receiving combined sewer overflow.

    Science.gov (United States)

    Scheurer, Marco; Heß, Stefanie; Lüddeke, Frauke; Sacher, Frank; Güde, Hans; Löffler, Herbert; Gallert, Claudia

    2015-01-01

    Combined sewer systems collect surface runoff as well as wastewater of industrial and domestic origin. During periods of heavy rainfall the capacity of the sewer system is exceeded and the overflow is discharged into receiving waters without any treatment. Consequently, combined sewer overflow (CSO) is considered as a major source of water pollution. This study investigates the effectiveness of a retention soil filter (RSF) for the removal of micropollutants as well as facultative pathogenic and antibiotic resistant bacteria from CSO. The removal of organic group parameters like total organic carbon was excellent and the removal efficiency for micropollutants of the RSF and the wastewater treatment plant (WWTP), which treats wastewater of the same origin during dry and normal weather conditions, was comparable. Compounds of high environmental concern like estrogens or certain pharmaceuticals, e.g. diclofenac, were completely eliminated or removed to a high degree during RSF passage. RSF treatment also reduced the number of E. coli, enterococci and staphylococci by 2.7, 2.2 and 2.4 log-units (median values), respectively. Obviously, some Staphylococcus species can better adapt to the conditions of the RSF than others as a shift of the abundance of the different species was observed when comparing the diversity of staphylococci obtained from the RSF influent and effluent. RSF treatment also decreased the absolute number of antibiotic resistant bacteria. The percentage of antibiotic resistant E. coli and staphylococci isolates also decreased during passage of the RSF, whereas the percentage of resistant enterococci did not change. For E. coli ampicillin and for enterococci and staphylococci erythromycin determined the antibiotic resistance level. The results demonstrate that RSFs can be considered as an adequate treatment option for CSO. The performance for the removal of micropollutants is comparable with a medium sized WWTP with conventional activated sludge

  2. Laboratory and field investigation of chemical disinfection of combined sewer overflow in Copenhagen area

    DEFF Research Database (Denmark)

    Chhetri, Ravi Kumar; Thornberg, Dines; Berner, Jesper

    We investigated the possibility to apply performic acid (PFA) and peracetic acid (PAA) for disinfection of combined sewer overflow (CSO) in existing CSO management infrastructures. The disinfection power of PFA and PAA to Escherichia coli (E. coli) and enterococcus were studied in batch scale...... and pre-field experiment. In batch scale experiment 2.5 mg·L -1 PAA removed around 4 log unit of E. coli and enterococcus from CSO with long contact time. Removal of E. coli and enterococcus from CSO were always around or above 3 log unit using 2-4 mg·L -1 PFA with short contact time in batch scale...... and pre-field experiment. There were no toxicological effect measured by Vibrio fischeri when CSO was disinfected with PFA, slight toxicological effect was observed on CSO disinfected with PAA. When the design for PFA based disinfection was applied to CSO collected from an authentic event. Disinfection...

  3. Chemical disinfection of combined sewer overflow waters using performic acid or peracetic acids.

    Science.gov (United States)

    Chhetri, Ravi Kumar; Thornberg, Dines; Berner, Jesper; Gramstad, Robin; Öjstedt, Ulrik; Sharma, Anitha Kumari; Andersen, Henrik Rasmus

    2014-08-15

    We investigated the possibility of applying performic acid (PFA) and peracetic acid (PAA) for disinfection of combined sewer overflow (CSO) in existing CSO management infrastructures. The disinfection power of PFA and PAA towards Escherichia coli (E. coli) and Enterococcus was studied in batch-scale and pre-field experiments. In the batch-scale experiment, 2.5 mg L(-1) PAA removed approximately 4 log unit of E. coli and Enterococcus from CSO with a 360 min contact time. The removal of E. coli and Enterococcus from CSO was always around or above 3 log units using 2-4 mg L(-1) PFA; with a 20 min contact time in both batch-scale and pre-field experiments. There was no toxicological effect measured by Vibrio fischeri when CSO was disinfected with PFA; a slight toxic effect was observed on CSO disinfected with PAA. When the design for PFA based disinfection was applied to CSO collected from an authentic event, the disinfection efficiencies were confirmed and degradation rates were slightly higher than predicted in simulated CSO. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. SEWER AND TANK FLUSHING FOR SEDIMENT, CORROSION AND POLLUTION CONTROL

    Science.gov (United States)

    This paper presents an overview of causes of sewer deterioration together with a discussion of control methods that can prevent or arrest this deterioration. In particular, the paper covers inline- and combined sewer overflow- (CSO) storage-tank-flushing systems for removal of se...

  5. Flood reduction as an ecosystem service of constructed wetlands for combined sewer overflow

    Science.gov (United States)

    Rizzo, A.; Bresciani, R.; Masi, F.; Boano, F.; Revelli, R.; Ridolfi, L.

    2018-05-01

    Urban runoff negatively impacts the receiving streams and different solutions have been proposed in literature to limit the effect of urbanization on the water balance. These solutions suggest to manage urban runoff in order to switch from a post-development river hydrograph (high peak and short duration) back again to a pre-development hydrograph (low peak and high duration). Combined sewer overflows (CSOs) represent severe pollutant sources for receiving streams due to the combination of first flush of roads and sewers and black water conveyed by combined sewer systems. Constructed wetlands for CSO treatment (CSO-CWs) are adopted with increasing frequency for reducing pollutant inputs to streams. Moreover, these systems exhibit the characteristic to behave similarly to ponds, wetlands, and bioretention systems that provide flood mitigation by decreasing the intensity of peak flows. This work aims to show the additional ecosystem service provided by CSO-CWs in term of limitation of the hydraulic impact of CSO on stream hydrograph. A mathematical model is developed to simulate the hydraulic behavior of a real case study situated in Gorla Maggiore (Italy), which includes vertical flow subsurface beds (VF) as first stage and a free water surface bed (FWS) as second stage. The model simulates the unsaturated flow within VF and the accumulation of water on the top of VF and within FWS. Results show a satisfactory lamination performance of the system for both single and up to 5 consecutive flood events, with a peak flow reduction ranging from 52.7% to 95.4%. Withdrawn of flow rate from the river in order to cope with long dry period does not significantly affect the lamination performances. The considered CSO-CW exhibits an excellent lamination efficiency also during more intense floods events, with a peak flow reduction of 86.2% for a CSO event with return period of 10 years. The flow rate frequency density function determined by the CSO-CW is more shifted towards

  6. A generalised Dynamic Overflow Risk Assessment (DORA) for Real Time Control of urban drainage systems

    DEFF Research Database (Denmark)

    Vezzaro, Luca; Grum, Morten

    2014-01-01

    An innovative and generalised approach to the integrated Real Time Control of urban drainage systems is presented. The Dynamic Overflow Risk Assessment (DORA) strategy aims to minimise the expected Combined Sewer Overflow (CSO) risk by considering (i) the water volume presently stored in the drai......An innovative and generalised approach to the integrated Real Time Control of urban drainage systems is presented. The Dynamic Overflow Risk Assessment (DORA) strategy aims to minimise the expected Combined Sewer Overflow (CSO) risk by considering (i) the water volume presently stored...... and their uncertainty contributed to further improving the performance of drainage systems. The results of this paper will contribute to the wider usage of global RTC methods in the management of urban drainage networks....

  7. Prediction of organic combined sewer sediment release and transport

    OpenAIRE

    Seco, Raquel Irene; Schellart, Alma Neeltje Antonia; Gómez Valentín, Manuel; Tait, Simon

    2018-01-01

    Accurate predictions of sediment loads released by sewer overflow discharges are important for being able to provide protection to vulnerable receiving waters. These predictions are sensitive to the estimated sediment characteristics and on the site conditions of in-pipe deposit formation. Their application without a detailed analysis and understanding of the initial conditions under which in-sewer deposits were formed normally results in very poor estimations. In this study, in-sewer sedimen...

  8. Sewer solids separation by sedimentation--the problem of modeling, validation and transferability.

    Science.gov (United States)

    Kutzner, R; Brombach, H; Geiger, W F

    2007-01-01

    Sedimentation of sewer solids in tanks, ponds and similar devices is the most relevant process for the treatment of stormwater and combined sewer overflows in urban collecting systems. In the past a lot of research work was done to develop deterministic models for the description of this separation process. But these modern models are not commonly accepted in Germany until today. Water Authorities are sceptical with regard to model validation and transferability. Within this paper it is checked whether this scepticism is reasonable. A framework-proposal for the validation of mathematical models with zero or one dimensional spatial resolution for particle separation processes for stormwater and combined sewer overflow treatment is presented. This proposal was applied to publications of repute on sewer solids separation by sedimentation. The result was that none of the investigated models described in literature passed the validation entirely. There is an urgent need for future research in sewer solids sedimentation and remobilization!

  9. Remaining Sites Verification Package for the 1607-F4 Sanitary Sewer System. Attachment to Waste Site Reclassification Form 2004-131

    International Nuclear Information System (INIS)

    Dittmer, L.M.

    2007-01-01

    The 1607-F4 waste site is the former location of the sanitary sewer system that serviced the former 115-F Gas Recirculation Building. The system included a septic tank, drain field, and associated pipeline that were in use from 1944 to 1965. The 1607-F4 waste site received unknown amounts of sanitary sewage from the 115-F Gas Recirculation Building and may have potentially contained hazardous and radioactive contamination. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling demonstrated that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also showed that residual contaminant concentrations are protective of groundwater and the Columbia River

  10. Attenuated Total Reflectance Fourier transform infrared spectroscopy for determination of long chain free fatty acid concentration in oily wastewater using the double wavenumber extrapolation technique

    Science.gov (United States)

    Long Chain Free Fatty Acids (LCFFAs) from the hydrolysis of fat, oil and grease (FOG) are major components in the formation of insoluble saponified solids known as FOG deposits that accumulate in sewer pipes and lead to sanitary sewer overflows (SSOs). A Double Wavenumber Extrapolative Technique (DW...

  11. Constructed Wetlands for Treatment of Combined Sewer Overflow in the US: A Review of Design Challenges and Application Status

    Directory of Open Access Journals (Sweden)

    Wendong Tao

    2014-11-01

    Full Text Available As combined sewer systems and centralized wastewater treatment facilities age, many communities in the world are challenged by management of combined sewer overflow (CSO. Constructed wetlands are considered to be one of the green infrastructure solutions to CSOs in the US. Despite the wide application of constructed wetlands to different types of wastewaters, the stochastic and intermittent nature of CSO presents challenges for design and performance assessment of constructed wetlands. This paper reviews the application status of CSO constructed wetlands in the US, assesses the benefits of CSO constructed wetlands, identifies challenges to designing CSO constructed wetlands, and proposes design considerations. This review finds that constructed wetlands are effective in CSO treatment and relatively less expensive to build than comparable grey infrastructure. Constructed wetlands not only remove pollutants, but also mitigate the event-associated flow regime. The design challenges include incorporating considerations of green infrastructure into permit requirements, determining design capacity for highly variable flows, requiring pretreatment, and needing adaptive design and intensive monitoring. Simultaneous monitoring of flow rate and water quality at both the inflow and outflow of CSO constructed wetlands is required for performance assessment and needed to support design, but is rarely available.

  12. The Characteristics of Waste Water Flow in a Danish Combined Sewer

    DEFF Research Database (Denmark)

    Schaarup-Jensen, Kjeld; Rasmussen, Michael R.

    2004-01-01

    have been analysed in order to extract some of their characteristics. Furthermore it is emphasised that the presence of a self-cleansing capacity of a combined sewer system is of vital importance in order to reduce the impact of combined sewer overflows on receiving waters. Whether or not the pipelines...

  13. SEWER NETWORK DISCHARGE OPTIMIZATION USING THE DYNAMIC PROGRAMMING

    Directory of Open Access Journals (Sweden)

    Viorel MINZU

    2015-12-01

    Full Text Available It is necessary to adopt an optimal control that allows an efficient usage of the existing sewer networks, in order to avoid the building of new retention facilities. The main objective of the control action is to minimize the overflow volume of a sewer network. This paper proposes a method to apply a solution obtained by discrete dynamic programming through a realistic closed loop system.

  14. Uncertainties Related to Extreme Event Statistics of Sewer System Surcharge and Overflow

    DEFF Research Database (Denmark)

    Schaarup-Jensen, Kjeld; Johansen, C.; Thorndahl, Søren Liedtke

    2005-01-01

    Today it is common practice - in the major part of Europe - to base design of sewer systems in urban areas on recommended minimum values of flooding frequencies related to either pipe top level, basement level in buildings or level of road surfaces. Thus storm water runoff in sewer systems is only...... proceeding in an acceptable manner, if flooding of these levels is having an average return period bigger than a predefined value. This practice is also often used in functional analysis of existing sewer systems. If a sewer system can fulfil recommended flooding frequencies or not, can only be verified...... by performing long term simulations - using a sewer flow simulation model - and draw up extreme event statistics from the model simulations. In this context it is important to realize that uncertainties related to the input parameters of rainfall runoff models will give rise to uncertainties related...

  15. Identifying the best locations to install flow control devices in sewer networks to enable in-sewer storage

    Science.gov (United States)

    Leitão, J. P.; Carbajal, J. P.; Rieckermann, J.; Simões, N. E.; Sá Marques, A.; de Sousa, L. M.

    2018-01-01

    The activation of available in-sewer storage volume has been suggested as a low-cost flood and combined sewer overflow mitigation measure. However, it is currently unknown what the attributes for suitable objective functions to identify the best location for flow control devices are and the impact of those attributes on the results. In this study, we present a novel location model and efficient algorithm to identify the best location(s) to install flow limiters. The model is a screening tool that does not require hydraulic simulations but rather considers steady state instead of simplistic static flow conditions. It also maximises in-sewer storage according to different reward functions that also considers the potential impact of flow control device failure. We demonstrate its usefulness on two real sewer networks, for which an in-sewer storage potential of approximately 2,000 m3 and 500 m3 was estimated with five flow control devices installed.

  16. Characteristics of the overflow pollution of storm drains with inappropriate sewage entry.

    Science.gov (United States)

    Yin, Hailong; Lu, Yi; Xu, Zuxin; Li, Huaizheng; Schwegler, Benedict R

    2017-02-01

    To probe the overflow pollution of separate storm drains with inappropriate sewage entries, in terms of the relationship between sewage entries and the corresponding dry-weather and wet-weather overflow, the monitoring activities were conducted in a storm drainage system in the Shanghai downtown area (374 ha). In this study site, samples from inappropriately entered dry-weather sewage and the overflow due to storm pumps operation on dry-weather and wet-weather days were collected and then monitored for six water quality constituents. It was found that overflow concentrations of dry-weather period could be higher than those of wet-weather period; under wet-weather period, the overflow concentrations of storm drains were close to or even higher than that of combined sewers. Relatively strong first flush mostly occurred under heavy rain that satisfied critical rainfall amount, maximum rainfall intensity, and maximum pumping discharge, while almost no first flush effect or only weak first flush effect was found for the other rainfall events. Such phenomenon was attributed to lower in-line pipe storage as compared to that of the combined sewers, and serious sediment accumulation within the storm pipes due to sewage entry. For this kind of system, treating a continuous overflow rate is a better strategy than treating the maximum amount of early part of the overflow. Correcting the key inappropriate sewage entries into storm drains should also be focused.

  17. The evaluation of rainfall influence on combined sewer overflows characteristics: the Berlin case study.

    Science.gov (United States)

    Sandoval, S; Torres, A; Pawlowsky-Reusing, E; Riechel, M; Caradot, N

    2013-01-01

    The present study aims to explore the relationship between rainfall variables and water quality/quantity characteristics of combined sewer overflows (CSOs), by the use of multivariate statistical methods and online measurements at a principal CSO outlet in Berlin (Germany). Canonical correlation results showed that the maximum and average rainfall intensities are the most influential variables to describe CSO water quantity and pollutant loads whereas the duration of the rainfall event and the rain depth seem to be the most influential variables to describe CSO pollutant concentrations. The analysis of partial least squares (PLS) regression models confirms the findings of the canonical correlation and highlights three main influences of rainfall on CSO characteristics: (i) CSO water quantity characteristics are mainly influenced by the maximal rainfall intensities, (ii) CSO pollutant concentrations were found to be mostly associated with duration of the rainfall and (iii) pollutant loads seemed to be principally influenced by dry weather duration before the rainfall event. The prediction quality of PLS models is rather low (R² < 0.6) but results can be useful to explore qualitatively the influence of rainfall on CSO characteristics.

  18. Comparing peracetic acid and hypochlorite for disinfection of combined sewer overflows: Effects of suspended-solids and pH.

    Science.gov (United States)

    McFadden, M; Loconsole, J; Schockling, A J; Nerenberg, R; Pavissich, J P

    2017-12-01

    Peracetic acid (PAA) is an alternative disinfectant that may be effective for combined sewer overflow (CSO) disinfection, but little is known about the effect of particle size on PAA disinfection efficiency. In this work, PAA and hypochlorite were compared as disinfectants, with a focus on the effect of wastewater particles. Inactivation experiments were conducted on suspended cultures of Escherichia coli and wastewater suspended solids. Tested size fractions included particle diameters disinfection efficiency decreased with increasing solids size. However, solids size had little effect on PAA disinfection. The PAA disinfection efficiency decreased at pH values above 7.5. Live/dead staining revealed that PAA disinfection leaves most cells in a viable but non-culturable condition. Fourier transform infrared spectroscopy (FTIR) analyses suggests that PAA and hypochlorite may inactivate E. coli bacteria by similar mechanisms. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Sewerage systems: Overflow problems and renovation methods

    Energy Technology Data Exchange (ETDEWEB)

    Tanttu, Unto [Plancenter Ltd. (Finland)

    1987-12-15

    Total investments in Finland (1984) spent on sewer systems were roughly FIM 590 million. A big share, about 14 % of this sum (FIM 82 million), was spent on rehabilitation of networks. But is this still enough? According to some evaluations the respective amount should be about FIM 500 million for rehabilitation only. So the question, how to keep the performance of sewer networks satisfactory in the future, is really important. The overflow problem is one of the most serious problems caused by old and improperly working sewer systems. Anyhow, several other aspects of a poor condition of sewers are to be seen: - excess hydraulic loading of treatment plants, - normal maintenance and operation (flushing, opening of clogs) increases, and is more expensive, - unexpected renovation works and interruptions in operation cause e.g. troubles in traffic, odour problems in the environment, hygienic hazards etc., - the performance of other underground networks (water pipes, district heating pipes etc.) may be threatened by earth crushings due to old sewers. In this paper a short description of these items is presented as well as a description of the sewer renovation methods used recently in Finland.

  20. Effects of combined sewer overflow and stormwater on indicator bacteria concentrations in the Tama River due to the high population density of Tokyo Metropolitan area.

    Science.gov (United States)

    Ham, Young-Sik; Kobori, Hiromi; Takasago, Masahisa

    2009-05-01

    The indicator bacteria (standard plate count, total coliform, and fecal coliform bacteria) concentrations have been investigated using six ambient habitats (population density, percent sewer penetration, stream flow rate (m(3)/sec), percent residential area, percent forest area and percent agricultural area) in the Tama River basin in Tokyo, Japan during June 2003 to January 2005. The downstream and tributary Tama River showed higher concentrations of TC and FC bacteria than the upstream waters, which exceeded an environmental quality standard for rivers and a bathing water quality criterion. It was estimated that combined sewer overflow (CSO) and stormwater effluents contributed -4-23% to the indicator bacteria concentrations of the Tama River. The results of multiple regression analyses show that the indicator bacteria concentrations of Tama River basin are significantly affected by population density. It is concluded that the Tama River received a significant bacterial contamination load originating from the anthropogenic source.

  1. Implementation of an integrated real-time control system of sewer system and waste water treatment plant in the city of Wilhelmshaven

    DEFF Research Database (Denmark)

    Seggelke, Katja; Löwe, Roland; Beeneken, Thomas

    2013-01-01

    A case study for integrated real-time control (RTC) of an urban drainage system in the city of Wilhelmshaven (Germany) is explained. The fuzzy based RTC strategy combines control of the sewer system and inflow to the waste water treatment plant. The main objective in controlling the sewer system...... is to reduce the number of overflows and the volume at a combined sewer overflow (CSO), located close to a bathing beach. Based on online measurements, the operation mode of two pumping stations is modified. This approach allows the safe activation of free storage volume in the sewer system without...... RTC system has been operational for approximately one year....

  2. A generalized Dynamic Overflow Risk Assessment (DORA) for urban drainage RTC

    DEFF Research Database (Denmark)

    Vezzaro, Luca; Grum, Morten

    2012-01-01

    An innovative generalized approach for integrated real time control of urban drainage systems is presented. The Dynamic Overflow Risk Assessment (DORA) strategy tries to minimize the expected overflow risk by considering (i) the water volume presently stored in the drainage network, (ii) the expe......An innovative generalized approach for integrated real time control of urban drainage systems is presented. The Dynamic Overflow Risk Assessment (DORA) strategy tries to minimize the expected overflow risk by considering (i) the water volume presently stored in the drainage network, (ii...... to reduce Combined Sewer Overflow loads and to optimize the flow discharged to the wastewater treatment plant. Also, the inclusion of forecasts and their uncertainty contributed to further improve the performance of drainage systems. The results of this paper will contribute to a wider usage of global RTC...

  3. CORAL off-line: an object-oriented tool for optimal control of sewer networks

    OpenAIRE

    Figueras, J.; Cembrano, Gabriela; Puig, Vicenç; Quevedo, Joseba; Salamero Sansalvado, María; Marti Marques, Joaquim

    2002-01-01

    This paper describes a tool to aid in the analysis and design of combined sewer networks. Complex drainage systems include actuators, like flow-diversion gates and detention tanks, which should be optimally controlled in order to minimize flooding and combined sewer overflow (CSO). Through these optimisations volume to waste water treatment plants (WWTP) is maximised. CORAL is a tool able to model a combined sewer network, simulate rain events, calculate actuators optimal policies, reproduce ...

  4. Watershed-scale impacts of stormwater green infrastructure on hydrology, nutrient fluxes, and combined sewer overflows in the mid-Atlantic region.

    Science.gov (United States)

    Pennino, Michael J; McDonald, Rob I; Jaffe, Peter R

    2016-09-15

    Stormwater green infrastructure (SGI), including rain gardens, detention ponds, bioswales, and green roofs, is being implemented in cities across the globe to reduce flooding, combined sewer overflows, and pollutant transport to streams and rivers. Despite the increasing use of urban SGI, few studies have quantified the cumulative effects of multiple SGI projects on hydrology and water quality at the watershed scale. To assess the effects of SGI, Washington, DC, Montgomery County, MD, and Baltimore County, MD, were selected based on the availability of data on SGI, water quality, and stream flow. The cumulative impact of SGI was evaluated over space and time by comparing watersheds with and without SGI, and by assessing how long-term changes in SGI impact hydrologic and water quality metrics over time. Most Mid-Atlantic municipalities have a goal of achieving 10-20% of the landscape drain runoff through SGI by 2030. Of these areas, Washington, DC currently has the greatest amount of SGI (12.7% of the landscape drained through SGI), while Baltimore County has the lowest (7.9%). When controlling for watersheds size and percent impervious surface cover, watersheds with greater amounts of SGI have less flashy hydrology, with 44% lower peak runoff, 26% less frequent runoff events, and 26% less variable runoff. Watersheds with more SGI also show 44% less NO3(-) and 48% less total nitrogen exports compared to watersheds with minimal SGI. There was no significant reduction in phosphorus exports or combined sewer overflows in watersheds with greater SGI. When comparing individual watersheds over time, increases in SGI corresponded to non-significant reductions in hydrologic flashiness compared to watersheds with no change in SGI. While the implementation of SGI is somewhat in its infancy in some regions, cities are beginning to have a scale of SGI where there are statistically significant differences in hydrologic patterns and water quality. Copyright © 2016 The Authors

  5. To what extent does variability of historical rainfall series influence extreme event statistics of sewer system surcharge and overflows?

    DEFF Research Database (Denmark)

    Schaarup-Jensen, Kjeld; Rasmussen, Michael R.; Thorndahl, Søren

    2008-01-01

    In urban drainage modeling long term extreme statistics has become an important basis for decision-making e.g. in connection with renovation projects. Therefore it is of great importance to minimize the uncertainties concerning long term prediction of maximum water levels and combined sewer...... overflow (CSO) in drainage systems. These uncertainties originate from large uncertainties regarding rainfall inputs, parameters, and assessment of return periods. This paper investigates how the choice of rainfall time series influences the extreme events statistics of max water levels in manholes and CSO...... gauges are located at a distance of max 20 kilometers from the catchment. All gauges are included in the Danish national rain gauge system which was launched in 1976. The paper describes to what extent the extreme events statistics based on these 9 series diverge from each other and how this diversity...

  6. To what extent does variability of historical rainfall series influence extreme event statistics of sewer system surcharge and overflows?

    DEFF Research Database (Denmark)

    Schaarup-Jensen, Kjeld; Rasmussen, Michael R.; Thorndahl, Søren

    2009-01-01

    In urban drainage modelling long term extreme statistics has become an important basis for decision-making e.g. in connection with renovation projects. Therefore it is of great importance to minimize the uncertainties concerning long term prediction of maximum water levels and combined sewer...... overflow (CSO) in drainage systems. These uncertainties originate from large uncertainties regarding rainfall inputs, parameters, and assessment of return periods. This paper investigates how the choice of rainfall time series influences the extreme events statistics of max water levels in manholes and CSO...... gauges are located at a distance of max 20 kilometers from the catchment. All gauges are included in the Danish national rain gauge system which was launched in 1976. The paper describes to what extent the extreme events statistics based on these 9 series diverge from each other and how this diversity...

  7. International evolution of fat, oil and grease (FOG) waste management - A review

    OpenAIRE

    Wallace, Thomas; Gibbons, David; O'Dwyer, Michael; Curran, Thomas P.

    2017-01-01

    In recent years, issues relating to fat, oil and grease (FOG) in sewer systems have intensified. In the media, sewer blockages caused by FOG waste deposits, commonly referred to as 'fatbergs', are becoming a reminder of the problems that FOG waste can cause when left untreated. These FOG blockages lead to sanitary sewer overflows, property flooding and contamination of water bodies with sewage. Despite these financial and environmentally detrimental effects, a homogenous FOG waste management ...

  8. Remaining Sites Verification Package for the 100-C-9:2 Sanitary Sewer Pipelines, Waste Site Reclassification Form 2004-013

    Energy Technology Data Exchange (ETDEWEB)

    L. M. Dittmer

    2007-07-11

    The 100-C-9:2 sanitary sewer pipelines include the feeder pipelines associated with the 1607-B8, the 1607-B9, the 1607-B10 and the 1607-B11 septic systems. Contaminated soil and piping from the feeder lines to the septic systems were removed and disposed of. The remaining soil in the excavations has been shown to meet the remedial action objectives specified in the Remaining Sites ROD. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

  9. A generic methodology for the optimisation of sewer systems using stochastic programming and self-optimizing control.

    Science.gov (United States)

    Mauricio-Iglesias, Miguel; Montero-Castro, Ignacio; Mollerup, Ane L; Sin, Gürkan

    2015-05-15

    The design of sewer system control is a complex task given the large size of the sewer networks, the transient dynamics of the water flow and the stochastic nature of rainfall. This contribution presents a generic methodology for the design of a self-optimising controller in sewer systems. Such controller is aimed at keeping the system close to the optimal performance, thanks to an optimal selection of controlled variables. The definition of an optimal performance was carried out by a two-stage optimisation (stochastic and deterministic) to take into account both the overflow during the current rain event as well as the expected overflow given the probability of a future rain event. The methodology is successfully applied to design an optimising control strategy for a subcatchment area in Copenhagen. The results are promising and expected to contribute to the advance of the operation and control problem of sewer systems. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Organic micropollutants discharged by combined sewer overflows - Characterisation of pollutant sources and stormwater-related processes.

    Science.gov (United States)

    Launay, Marie A; Dittmer, Ulrich; Steinmetz, Heidrun

    2016-11-01

    To characterise emissions from combined sewer overflows (CSOs) regarding organic micropollutants, a monitoring study was undertaken in an urban catchment in southwest Stuttgart, Germany. The occurrence of 69 organic micropollutants was assessed at one CSO outfall during seven rain events as well as in the sewage network at the influent of the wastewater treatment plant (WWTP) and in the receiving water. Several pollutant groups like pharmaceuticals and personal care products (PPCPs), urban biocides and pesticides, industrial chemicals, organophosphorus flame retardants, plasticisers and polycyclic aromatic hydrocarbons (PAHs) were chosen for analysis. Out of the 69 monitored substances, 60 were detected in CSO discharges. The results of this study show that CSOs represent an important pathway for a wide range of organic micropollutants from wastewater systems to urban receiving waters. For most compounds detected in CSO samples, event mean concentrations varied between the different events in about one order of magnitude range. When comparing CSO concentrations with median wastewater concentrations during dry weather, two main patterns could be observed depending on the source of the pollutant: (i) wastewater is diluted by stormwater; (ii) stormwater is the most important source of a pollutant. Both wastewater and stormwater only play an important role in pollutant concentration for a few compounds. The proportion of stormwater calculated with the conductivity is a suitable indicator for the evaluation of emitted loads of dissolved wastewater pollutants, but not for all compounds. In fact, this study demonstrates that remobilisation of in-sewer deposits contributed from 10% to 65% to emissions of carbamazepine in CSO events. The contribution of stormwater to CSO emitted loads was higher than 90% for all herbicides as well as for PAHs. Regarding the priority substance di(2-ethylhexyl)phthalate (DEHP), this contribution varied between 39% and 85%. The PAH

  11. STRUCTURAL CAPABILITIES OF NO-DIG MANHOLE REHABILITATION (WE&RF Report INFR1R12)

    Science.gov (United States)

    Failure of a manhole may have catastrophic consequences such as a sinkhole. At a minimum, wastewater flow will be blocked and flow upstream of the manhole will backup, causing a sanitary sewer overflow (SSO). Accordingly, the structural condition of a manhole is an important perf...

  12. Remaining Sites Verification Package for the 100-C-9:2 Sanitary Sewer Pipelines. Attachment to Waste Site Reclassification Form 2004-013

    International Nuclear Information System (INIS)

    Dittmer, L.M.

    2007-01-01

    The 100-C-9:2 sanitary sewer pipelines include the feeder pipelines associated with the 1607-B8, the 1607-B9, the 1607-B10 and the 1607-B11 septic systems. Contaminated soil and piping from the feeder lines to the septic systems were removed and disposed of. The remaining soil in the excavations has been shown to meet the remedial action objectives specified in the Remaining Sites ROD. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River

  13. Modelling of sedimentation and remobilization in in-line storage sewers for stormwater treatment.

    Science.gov (United States)

    Frehmann, T; Flores, C; Luekewille, F; Mietzel, T; Spengler, B; Geiger, W F

    2005-01-01

    A special arrangement of combined sewer overflow tanks is the in-line storage sewer with downstream discharge (ISS-down). This layout has the advantage that, besides the sewer system, no other structures are required for stormwater treatment. The verification of the efficiency with respect to the processes of sedimentation and remobilization of sediment within the in-line storage sewer with downstream discharge is carried out in a combination of a field and a pilot plant study. The model study was carried out using a pilot plant model scaled 1:13. The following is intended to present some results of the pilot plant study and the mathematical empirical modelling of the sedimentation and remobilization process.

  14. Model evaluation of faecal contamination in coastal areas affected by urban rivers receiving combined sewer overflows.

    Science.gov (United States)

    Shibata, T; Kojima, K; Lee, S A; Furumai, H

    2014-01-01

    Odaiba seaside park is one of the most popular waterfronts in Tokyo Bay, but is easily affected by wet weather pollutant loads through combined sewer overflows (CSOs). The monitoring data of Escherichia coli clearly showed high faecal contamination after a rainfall event on 9-11 November 2007. We estimated the amounts of discharge volume and E. coli pollutant loads of urban rivers receiving CSO from rainfall chambers as well as pumping stations and primary effluent discharge. The result suggested that Sumida River and Meguro River were more influential to the Odaiba coastal area than other sources including the nearest wastewater treatment plant. Subsequently, we simulated the dynamic behaviour of E. coli by a three-dimensional (3D) hydro-dynamic and water quality model. The model simulation reproduced that E. coli concentration after the rainfall event increased rapidly at first and later gradually decreased. The simulations with and without inflow pollutant loads from urban rivers suggested that the E. coli concentration can be influenced by the Meguro River just after the rainfall event and Sumida River about 1 week later. From the spatial and temporal distribution of surface E. coli concentration, after at least 6 days from the rainfall event, high faecal contamination spread to the whole of the coastal area.

  15. SprayWall, Cured-In-Placed Method for Manhole Rehabilitation

    OpenAIRE

    ECT Team, Purdue

    2007-01-01

    Manholes and other underground structures commonly account for 25-30 % of infiltration and up to 70% of inflow in sanitary sewer collection systems. These will cause sewer overflow and endanger the nearby environment. SprayWall is a spray-applied, cured-in-place method of construction and is primarily used in manholes. It uses urethane material that provides excellent corrosion resistance. SprayWall is structural and can withstand ground water loads on a long-term basis.

  16. Simulating groundwater-induced sewer flooding

    Science.gov (United States)

    Mijic, A.; Mansour, M.; Stanic, M.; Jackson, C. R.

    2016-12-01

    During the last decade, Chalk catchments of southern England experienced severe groundwater flooding. High groundwater levels resulted in the groundwater ingress into the sewer network that led to restricted toilet use and the overflow of diluted, but untreated sewage to road surfaces, rivers and water courses. In response to these events the water and sewerage company Thames Water Utilities Ltd (TWUL) had to allocate significant funds to mitigate the impacts. It was estimated that approximately £19m was spent responding to the extreme wet weather of 2013-14, along with the use of a fleet of over 100 tankers. However, the magnitude of the event was so large that these efforts could not stop the discharge of sewage to the environment. This work presents the analysis of the risk of groundwater-induced sewer flooding within the Chalk catchment of the River Lambourn, Berkshire. A spatially distributed groundwater model was used to assess historic groundwater flood risk and the potential impacts of changes in future climate. We then linked this model to an urban groundwater model to enable us to simulate groundwater-sewer interaction in detail. The modelling setup was used to identify relationships between infiltration into sewers and groundwater levels at specific points on TWUL's sewer network, and to estimate historic and future groundwater flood risk, and how this varies across the catchment. The study showed the significance of understanding the impact of groundwater on the urban water systems, and producing information that can inform a water company's response to groundwater flood risk, their decision making process and their asset management planning. However, the knowledge gained through integrated modelling of groundwater-sewer interactions has highlighted limitations of existing approaches for the simulation of these coupled systems. We conclude this work with number of recommendations about how to improve such hydrological/sewer analysis.

  17. DESIGN MANUAL: SULFIDE CONTROL IN SANITARY SEWERAGE SYSTEMS

    Science.gov (United States)

    One characteristic by which sanitary sewage is known to the public is its potential for creating odor nuisances. Sometimes it is the odors escaping from sewer manholes that cause complaints; more commonly, the source is a wastewater treatment plant. Yet there are wastewater treat...

  18. Nitrogen patterns in subsurface waters of the Yzeron stream: effect of combined sewer overflows and subsurface-surface water mixing.

    Science.gov (United States)

    Aucour, A M; Bariac, T; Breil, P; Namour, P; Schmitt, L; Gnouma, R; Zuddas, P

    2013-01-01

    Urbanization subjects streams to increased nitrogen loads. Therefore studying nitrogen forms at the interface between urban stream and groundwater is important for water resource management. In this study we report results on water δ(18)O and nitrogen forms in subsurface waters of a stream (Yzeron, France). The sites studied were located upstream and downstream of combined sewer overflows (CSO) in a rural area and a periurban area, respectively. Water δ(18)O allowed us to follow the mixing of subsurface water with surface water. Dissolved organic nitrogen and organic carbon of fine sediment increased by 20-30% between rural and periurban subsurface waters in the cold season, under high flow. The highest nitrate levels were observed in rural subsurface waters in the cold season. The lowest nitrate levels were found in periurban subsurface waters in the warm season, under low flow. They corresponded to slow exchange of subsurface waters with channel water. Thus reduced exchange between surface and subsurface waters and organic-matter-rich input seemed to favor nitrate reduction in the downstream, periurban, subsurface waters impacted by CSO.

  19. Extreme Precipitation and Emergency Room Visits for Gastrointestinal Illness in Areas With and Without Combined Sewer Systems: An Analysis of Massachusetts Data, 2003-2007

    Science.gov (United States)

    Background: Combined sewer overflows (CSOs) occur in combined sewer systems when sewage and stormwater runoff discharge into waterbodies potentially contaminating water sources. CSOs are often caused by heavy precipitation and are expected to increase with increasing extreme pre...

  20. Leveraging Spatial Data to Assess Where Sewers Leak and Impinge on Urban Water Quality

    Science.gov (United States)

    Holden, P. A.; Roehrdanz, P.; Lee, D. G.; Feraud, M.; Maier, M.; Means, J. C.; Snyder, S.

    2017-12-01

    In the modern urban water environment (UWE), engineered systems provide wastewater collection, treatment, and reuse; stormwater and graywater management; and potable water treatment, distribution and conservation. Underpinning such systems are physical, private and public, infrastructures whose integrities impinge on major goals of protecting groundwater and surface water resources, managing flooding, and securing safe drinking water. Here we study sanitary sewers, i.e. the main pipes in wastewater collection systems that improve public health by reducing pathogen exposure, and that afford reclaiming water for beneficial reuse. We ask: what is the relationship between sanitary sewer integrity and nearby water quality? Research methods include acquiring spatially defined sewer metadata that are analyzed using a published pipe leakage algorithm with variables of age, depth, materials of construction, length, diameter, slope, and nature of overburden. By executing the algorithm within a geographical information system (GIS), coupled with relating leakage probabilities to shallow groundwater table proximities—also digitally assembled, from well depth data—maps of wastewater exfiltration scores were produced for a city. Field sampling shallow groundwater allowed assessing concentrations of wastewater indicator compounds including personal care products and pharmaceuticals (PCPPs), and showing positive relationships between wastewater exfiltration scores and tryptophan-like fluorescence (TLF), reactive nitrogen species, an artificial sweetener acesulfame, and a stable isotope of oxygen (δ18O). The approach is extended to surface waters, where exfiltrating wastewater may transport from leaking sanitary sewers through the unsaturated zone to nearby storm drains or to storm drains that are submerged in contaminated groundwater. Spatially assessing sewer interactions within the UWE, as such, could aid urban infrastructure management and investment.

  1. Coordinated management of combined sewer overflows by means of environmental decision support systems.

    Science.gov (United States)

    Murla, Damian; Gutierrez, Oriol; Martinez, Montse; Suñer, David; Malgrat, Pere; Poch, Manel

    2016-04-15

    During heavy rainfall, the capacity of sewer systems and wastewater treatment plants may be surcharged producing uncontrolled wastewater discharges and a depletion of the environmental quality. Therefore there is a need of advanced management tools to tackle with these complex problems. In this paper an environmental decision support system (EDSS), based on the integration of mathematical modeling and knowledge-based systems, has been developed for the coordinated management of urban wastewater systems (UWS) to control and minimize uncontrolled wastewater spills. Effectiveness of the EDSS has been tested in a specially designed virtual UWS, including two sewers systems, two WWTP and one river subjected to typical Mediterranean rain conditions. Results show that sewer systems, retention tanks and wastewater treatment plants improve their performance under wet weather conditions and that EDSS can be very effective tools to improve the management and prevent the system from possible uncontrolled wastewater discharges. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. A generic methodology for the optimisation of sewer systems using stochastic programming and self-optimizing control

    DEFF Research Database (Denmark)

    Maurico-Iglesias, Miguel; Castro, Ignacio Montero; Mollerup, Ane Loft

    2015-01-01

    . Such controller is aimed at keeping the system close to the optimal performance, thanks to an optimal selection of controlled variables. The definition of an optimal performance was carried out by a two-stage optimisation (stochastic and deterministic) to take into account both the overflow during the current......The design of sewer system control is a complex task given the large size of the sewer networks, the transient dynamics of the water flow and the stochastic nature of rainfall. This contribution presents a generic methodology for the design of a self-optimising controller in sewer systems...

  3. Deep Tunnel for Regulating Combined Sewer Overflow Pollution and Flood Disaster: A Case Study in Guangzhou City, China

    Directory of Open Access Journals (Sweden)

    Haichun Wu

    2016-08-01

    Full Text Available The DongHaoChong (DHC basin is located in the central city zone of Guangzhou City, China. Owing to the high density of buildings and low quality of the drainage pipe network in the city, diversion of rain and sewage is difficult. Waterlogging occurs frequently and combined sewer overflow (CSO pollution is a serious problem during the rainy season. Therefore, a deep tunnel for the DongHaoChong basin has been planned and its construction is currently underway. An urban rainstorm model for the DongHaoChong basin was developed on the basis of the Storm Water Management Model (SWMM, and both the interception effect of CSO pollution and the degree of mitigation of flood were analyzed. Reasonable scenarios for the deep tunnel in terms of rainstorms with different design recurrence periods were evaluated. From the viewpoints of preventing rainstorm waterlogging disasters and protecting water quality in the region downstream of DongHaoChong River, the river flood control and drainage capacities of the region were improved to a 2-year rainstorm design recurrence period by the construction of the deep tunnel. Furthermore, the main pollutant load of the CSO is expected to be reduced by about 30%–40%.

  4. Catchment & sewer network simulation model to benchmark control strategies within urban wastewater systems

    DEFF Research Database (Denmark)

    Saagi, Ramesh; Flores Alsina, Xavier; Fu, Guangtao

    2016-01-01

    This paper aims at developing a benchmark simulation model to evaluate control strategies for the urban catchment and sewer network. Various modules describing wastewater generation in the catchment, its subsequent transport and storage in the sewer system are presented. Global/local overflow based...... evaluation criteria describing the cumulative and acute effects are presented. Simulation results show that the proposed set of models is capable of generating daily, weekly and seasonal variations as well as describing the effect of rain events on wastewater characteristics. Two sets of case studies...

  5. Narratives of Public Health in Dickens's Journalism: The Trouble with Sanitary Reform.

    Science.gov (United States)

    Smith, Ralph F

    2015-01-01

    Although Dickens is still known as having been a highly visible supporter of England's well-known nineteenth-century sanitary movement, he became, in fact, deeply troubled by many of this movement's fundamental tenets, as evidenced by journal narratives on fever that he edited and wrote in the mid-nineteenth century. Rather than water and sewer engineering works and a sanitary regime policed by government agencies as envisaged by Edwin Chadwick and other sanitary reformers, Dickens's view by 1855 was that only a massive erasure of the existing social and political systems and their replacement by an utterly new infrastructure would suffice.

  6. Design and Development of Vision Based Blockage Clearance Robot for Sewer Pipes

    Directory of Open Access Journals (Sweden)

    Krishna Prasad Nesaian

    2012-03-01

    Full Text Available Robotic technology is one of the advanced technologies, which is capable of completing tasks at situations where humans are unable to reach, see or survive. The underground sewer pipelines are the major tools for the transportation of effluent water. A lot of troubles caused by blockage in sewer pipe will lead to overflow of effluent water, sanitation problems. So robotic vehicle that is capable of traveling at underneath effluent water determining blockage using ultrasonic sensors and clearing by means of drilling mechanism is done. In addition to that wireless camera is fixed which acts as a robot vision by which we can monitor video and capture images using MATLAB tool. Thus in this project a prototype model of underground sewer pipe blockage clearance robot with drilling type will be developed

  7. Remaining Sites Verification Package for the 1607-B2 Septic System and 100-B-14:2 Sanitary Sewer System, Waste Site Reclassification Form 2004-006

    Energy Technology Data Exchange (ETDEWEB)

    L. M. Dittmer

    2007-03-21

    The 100-B-14:2 subsite encompasses the former sanitary sewer feeder lines associated with the 1607-B2 and 1607-B7 septic systems. Feeder lines associated with the 185/190-B building have also been identified as the 100-B-14:8 subsite, and feeder lines associated with the 1607-B7 septic system have also been identified as the 100-B-14:9 subsite. These two subsites have been administratively cancelled to resolve the redundancy. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

  8. Groundwater infiltration, surface water inflow and sewerage exfiltration considering hydrodynamic conditions in sewer systems.

    Science.gov (United States)

    Karpf, Christian; Hoeft, Stefan; Scheffer, Claudia; Fuchs, Lothar; Krebs, Peter

    2011-01-01

    Sewer systems are closely interlinked with groundwater and surface water. Due to leaks and regular openings in the sewer system (e.g. combined sewer overflow structures with sometimes reverse pressure conditions), groundwater infiltration and surface water inflow as well as exfiltration of sewage take place and cannot be avoided. In the paper a new hydrodynamic sewer network modelling approach will be presented, which includes--besides precipitation--hydrographs of groundwater and surface water as essential boundary conditions. The concept of the modelling approach and the models to describe the infiltration, inflow and exfiltration fluxes are described. The model application to the sewerage system of the City of Dresden during a flood event with complex conditions shows that the processes of infiltration, exfiltration and surface water inflows can be described with a higher reliability and accuracy, showing that surface water inflow causes a pronounced system reaction. Further, according to the simulation results, a high sensitivity of exfiltration rates on the in-sewer water levels and a relatively low influence of the dynamic conditions on the infiltration rates were found.

  9. Remaining Sites Verification Package for the 100-F-26:9, 1607-F2 Sanitary Sewer Pipelines. Attachment to Waste Site Reclassification Form 2008-029

    International Nuclear Information System (INIS)

    Capron, J.M.

    2008-01-01

    The 100-F-26:9 underground pipeline subsite consists of the sanitary sewers servicing the 105-F, 108-F, 184-F, 185-F, and 190-F buildings, and the 1700-F administration and service buildings (1704-F, 1707-F, 1707-FA, 1713-F, 1717-F, 1719-F, and 1722-F). In accordance with this evaluation, the confirmatory and verification sampling results support a reclassification of this site to Interim Closed Out. The current site conditions achieve the remedial action objectives and the corresponding remedial action goals established in the Remaining Sites ROD. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River

  10. To what extent does variability of historical rainfall series influence extreme event statistics of sewer system surcharge and overflows?

    Science.gov (United States)

    Schaarup-Jensen, K; Rasmussen, M R; Thorndahl, S

    2009-01-01

    In urban drainage modelling long-term extreme statistics has become an important basis for decision-making e.g. in connection with renovation projects. Therefore it is of great importance to minimize the uncertainties with regards to long-term prediction of maximum water levels and combined sewer overflow (CSO) in drainage systems. These uncertainties originate from large uncertainties regarding rainfall inputs, parameters, and assessment of return periods. This paper investigates how the choice of rainfall time series influences the extreme events statistics of max water levels in manholes and CSO volumes. Traditionally, long-term rainfall series, from a local rain gauge, are unavailable. In the present case study, however, long and local rain series are available. 2 rainfall gauges have recorded events for approximately 9 years at 2 locations within the catchment. Beside these 2 gauges another 7 gauges are located at a distance of max 20 kilometers from the catchment. All gauges are included in the Danish national rain gauge system which was launched in 1976. The paper describes to what extent the extreme events statistics based on these 9 series diverge from each other and how this diversity can be handled, e.g. by introducing an "averaging procedure" based on the variability within the set of statistics. All simulations are performed by means of the MOUSE LTS model.

  11. Risk-based decision making to manage water quality failures caused by combined sewer overflows

    Science.gov (United States)

    Sriwastava, A. K.; Torres-Matallana, J. A.; Tait, S.; Schellart, A.

    2017-12-01

    Regulatory authorities set certain environmental permit for water utilities such that the combined sewer overflows (CSO) managed by these companies conform to the regulations. These utility companies face the risk of paying penalty or negative publicity in case they breach the environmental permit. These risks can be addressed by designing appropriate solutions such as investing in additional infrastructure which improve the system capacity and reduce the impact of CSO spills. The performance of these solutions is often estimated using urban drainage models. Hence, any uncertainty in these models can have a significant effect on the decision making process. This study outlines a risk-based decision making approach to address water quality failure caused by CSO spills. A calibrated lumped urban drainage model is used to simulate CSO spill quality in Haute-Sûre catchment in Luxembourg. Uncertainty in rainfall and model parameters is propagated through Monte Carlo simulations to quantify uncertainty in the concentration of ammonia in the CSO spill. A combination of decision alternatives such as the construction of a storage tank at the CSO and the reduction in the flow contribution of catchment surfaces are selected as planning measures to avoid the water quality failure. Failure is defined as exceedance of a concentration-duration based threshold based on Austrian emission standards for ammonia (De Toffol, 2006) with a certain frequency. For each decision alternative, uncertainty quantification results into a probability distribution of the number of annual CSO spill events which exceed the threshold. For each alternative, a buffered failure probability as defined in Rockafellar & Royset (2010), is estimated. Buffered failure probability (pbf) is a conservative estimate of failure probability (pf), however, unlike failure probability, it includes information about the upper tail of the distribution. A pareto-optimal set of solutions is obtained by performing mean

  12. Modelling the impact of soakaway retrofits on combined sewage overflows in a 3km2 urban catchment in Copenhagen, Denmark

    DEFF Research Database (Denmark)

    Roldin, Maria Kerstin; Fryd, Ole; Jeppesen, Jan

    2012-01-01

    a more realistic scenario where only 8% of the impervious area was connected to soakaways and the reduction in CSO volume was 24%. The potential and realistic scenarios were modelled both with hydraulic coupling between soakaway and sewer, and as fully disconnected. Results show that infiltration...... step led to a potential infiltration scenario where 65% of the total impervious area was connected to soakaways, and resulted in an estimated reduction in annual sewage overflow volume of 68%. This scenario was then further developed in the third step by adding groundwater constraints, which formed...... than the fully disconnected model for the potential infiltration scenario, whereas no difference is seen between these two models in the realistic infiltration scenario. The effect of infiltration on combined sewer overflows is thus expected to be limited in the case study area. General conclusions...

  13. Constructed Wetlands for Combined Sewer Overflow Treatment—Comparison of German, French and Italian Approaches

    Directory of Open Access Journals (Sweden)

    Daniel Meyer

    2012-12-01

    Full Text Available Combined sewer systems are designed to transport stormwater surface run off in addition to the dry weather flows up to defined limits. In most European countries, hydraulic loads greater than the design flow are discharged directly into receiving water bodies, with minimal treatment (screening, sedimentation, or with no treatment at all. One feasible solution to prevent receiving waters from strong negative impacts seems to be the application of vertical flow constructed wetlands. In Germany, first attempts to use this ecological technology were recognized in early 1990s. Since then, further development continued until a high level of treatment performance was reached. During recent years the national “state-of-the-art” (defined in 2005 was adapted in other European countries, including France and Italy. Against the background of differing national requirements in combined sewer system design, substantial developmental steps were taken. The use of coarser filter media in combination with alternating loadings of separated filter beds allows direct feedings with untreated combined runoff. Permanent water storage in deep layers of the wetland improves the system’s robustness against extended dry periods, but contains operational risks. Besides similar functions (but different designs and layouts, correct dimensioning of all approaches suffers from uncertainties in long-term rainfall predictions as well as inside sewer system simulation tools.

  14. Green Infrastructure Simulation and Optimization to Achieve Combined Sewer Overflow Reductions in Philadelphia's Mill Creek Sewershed

    Science.gov (United States)

    Cohen, J. S.; McGarity, A. E.

    2017-12-01

    The ability for mass deployment of green stormwater infrastructure (GSI) to intercept significant amounts of urban runoff has the potential to reduce the frequency of a city's combined sewer overflows (CSOs). This study was performed to aid in the Overbrook Environmental Education Center's vision of applying this concept to create a Green Commercial Corridor in Philadelphia's Overbrook Neighborhood, which lies in the Mill Creek Sewershed. In an attempt to further implement physical and social reality into previous work using simulation-optimization techniques to produce GSI deployment strategies (McGarity, et al., 2016), this study's models incorporated land use types and a specific neighborhood in the sewershed. The low impact development (LID) feature in EPA's Storm Water Management Model (SWMM) was used to simulate various geographic configurations of GSI in Overbrook. The results from these simulations were used to obtain formulas describing the annual CSO reduction in the sewershed based on the deployed GSI practices. These non-linear hydrologic response formulas were then implemented into the Storm Water Investment Strategy Evaluation (StormWISE) model (McGarity, 2012), a constrained optimization model used to develop optimal stormwater management practices on the watershed scale. By saturating the avenue with GSI, not only will CSOs from the sewershed into the Schuylkill River be reduced, but ancillary social and economic benefits of GSI will also be achieved. The effectiveness of these ancillary benefits changes based on the type of GSI practice and the type of land use in which the GSI is implemented. Thus, the simulation and optimization processes were repeated while delimiting GSI deployment by land use (residential, commercial, industrial, and transportation). The results give a GSI deployment strategy that achieves desired annual CSO reductions at a minimum cost based on the locations of tree trenches, rain gardens, and rain barrels in specified land

  15. Assessment of erosion and sedimentation dynamic in a combined sewer network using online turbidity monitoring.

    Science.gov (United States)

    Bersinger, T; Le Hécho, I; Bareille, G; Pigot, T

    2015-01-01

    Eroded sewer sediments are a significant source of organic matter discharge by combined sewer overflows. Many authors have studied the erosion and sedimentation processes at the scale of a section of sewer pipe and over short time periods. The objective of this study was to assess these processes at the scale of an entire sewer network and over 1 month, to understand whether phenomena observed on a small scale of space and time are still valid on a larger scale. To achieve this objective the continuous monitoring of turbidity was used. First, the study of successive rain events allows observation of the reduction of the available sediment and highlights the widely different erosion resistance for the different sediment layers. Secondly, calculation of daily chemical oxygen demand (COD) fluxes during the entire month was performed showing that sediment storage in the sewer pipe after a rain period is important and stops after 5 days. Nevertheless, during rainfall events, the eroded fluxes are more important than the whole sewer sediment accumulated during a dry weather period. This means that the COD fluxes promoted by runoff are substantial. This work confirms, with online monitoring, most of the conclusions from other studies on a smaller scale.

  16. Bayesian analysis for erosion modelling of sediments in combined sewer systems.

    Science.gov (United States)

    Kanso, A; Chebbo, G; Tassin, B

    2005-01-01

    Previous research has confirmed that the sediments at the bed of combined sewer systems are the main source of particulate and organic pollution during rain events contributing to combined sewer overflows. However, existing urban stormwater models utilize inappropriate sediment transport formulas initially developed from alluvial hydrodynamics. Recently, a model has been formulated and profoundly assessed based on laboratory experiments to simulate the erosion of sediments in sewer pipes taking into account the increase in strength with depth in the weak layer of deposits. In order to objectively evaluate this model, this paper presents a Bayesian analysis of the model using field data collected in sewer pipes in Paris under known hydraulic conditions. The test has been performed using a MCMC sampling method for calibration and uncertainty assessment. Results demonstrate the capacity of the model to reproduce erosion as a direct response to the increase in bed shear stress. This is due to the model description of the erosional strength in the deposits and to the shape of the measured bed shear stress. However, large uncertainties in some of the model parameters suggest that the model could be over-parameterised and necessitates a large amount of informative data for its calibration.

  17. Human Bacteroides and total coliforms as indicators of recent combined sewer overflows and rain events in urban creeks.

    Science.gov (United States)

    McGinnis, Shannon; Spencer, Susan; Firnstahl, Aaron; Stokdyk, Joel; Borchardt, Mark; McCarthy, David T; Murphy, Heather M

    2018-07-15

    Combined sewer overflows (CSOs) are a known source of human fecal pollution and human pathogens in urban water bodies, which may present a significant public health threat. To monitor human fecal contamination in water, bacterial fecal indicator organisms (FIOs) are traditionally used. However, because FIOs are not specific to human sources and do not correlate with human pathogens, alternative fecal indicators detected using qPCR are becoming of interest to policymakers. For this reason, this study measured correlations between the number and duration of CSOs and mm of rainfall, concentrations of traditional FIOs and alternative indicators, and the presence of human pathogens in two urban creeks. Samples were collected May-July 2016 and analyzed for concentrations of FIOs (total coliforms and E. coli) using membrane filtration as well as for three alternative fecal indicators (human Bacteroides HF183 marker, human polyomavirus (HPoV), pepper mild mottle virus (PMMoV)) and nine human pathogens using qPCR. Four of the nine pathogens analyzed were detected at these sites including adenovirus, Enterohemorrhagic E. coli, norovirus, and Salmonella. Among all indicators studied, human Bacteroides and total coliforms were significantly correlated with recent CSO and rainfall events, while E. coli, PMMoV, and HPoV did not show consistent significant correlations. Further, human Bacteroides were a more specific indicator, while total coliforms were a more sensitive indicator of CSO and rainfall events. Results may have implications for the use and interpretation of these indicators in future policy or monitoring programs. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Human Bacteroides and total coliforms as indicators of recent combined sewer overflows and rain events in urban creeks

    Science.gov (United States)

    McGinnis, Shannon; Spencer, Susan K.; Firnstahl, Aaron; Stokdyk, Joel; Borchardt, Mark A.; McCarthy, David; Murphy, Heather

    2018-01-01

    Combined sewer overflows (CSOs) are a known source of human fecal pollution and human pathogens in urban water bodies, which may present a significant public health threat. To monitor human fecal contamination in water, bacterial fecal indicator organisms (FIOs) are traditionally used. However, because FIOs are not specific to human sources and do not correlate with human pathogens, alternative fecal indicators detected using qPCR are becoming of interest to policymakers. For this reason, this study measured correlations between the number and duration of CSOs and mm of rainfall, concentrations of traditional FIOs and alternative indicators, and the presence of human pathogens in two urban creeks. Samples were collected May–July 2016 and analyzed for concentrations of FIOs (total coliforms and E. coli) using membrane filtration as well as for three alternative fecal indicators (human Bacteroides HF183 marker, human polyomavirus (HPoV), pepper mild mottle virus (PMMoV)) and nine human pathogens using qPCR. Four of the nine pathogens analyzed were detected at these sites including adenovirus, Enterohemorrhagic E. coli, norovirus, and Salmonella. Among all indicators studied, human Bacteroides and total coliforms were significantly correlated with recent CSO and rainfall events, while E. coli, PMMoV, and HPoV did not show consistent significant correlations. Further, human Bacteroides were a more specific indicator, while total coliforms were a more sensitive indicator of CSO and rainfall events. Results may have implications for the use and interpretation of these indicators in future policy or monitoring programs.

  19. Peracetic acid as an alternative disinfection technology for wet weather flows.

    Science.gov (United States)

    Coyle, Elizabeth E; Ormsbee, Lindell E; Brion, Gail M

    2014-08-01

    Rain-induced wet weather flows (WWFs) consist of combined sewer overflows, sanitary sewer overflows, and stormwater, all of which introduce pathogens to surface waters when discharged. When people come into contact with the contaminated surface water, these pathogens can be transmitted resulting in severe health problems. As such, WWFs should be disinfected. Traditional disinfection technologies are typically cost-prohibitive, can yield toxic byproducts, and space for facilities is often limited, if available. More cost-effective alternative technologies, requiring less space and producing less harmful byproducts are currently being explored. Peracetic acid (PAA) was investigated as one such alternative and this research has confirmed the feasibility and applicability of using PAA as a disinfectant for WWFs. Peracetic acid doses ranging from 5 mg/L to 15 mg/L over contact times of 2 to 10 minutes were shown to be effective and directly applicable to WWF disinfection.

  20. Vision-based system for the control and measurement of wastewater flow rate in sewer systems.

    Science.gov (United States)

    Nguyen, L S; Schaeli, B; Sage, D; Kayal, S; Jeanbourquin, D; Barry, D A; Rossi, L

    2009-01-01

    Combined sewer overflows and stormwater discharges represent an important source of contamination to the environment. However, the harsh environment inside sewers and particular hydraulic conditions during rain events reduce the reliability of traditional flow measurement probes. In the following, we present and evaluate an in situ system for the monitoring of water flow in sewers based on video images. This paper focuses on the measurement of the water level based on image-processing techniques. The developed image-based water level algorithms identify the wall/water interface from sewer images and measure its position with respect to real world coordinates. A web-based user interface and a 3-tier system architecture enable the remote configuration of the cameras and the image-processing algorithms. Images acquired and processed by our system were found to reliably measure water levels and thereby to provide crucial information leading to better understand particular hydraulic behaviors. In terms of robustness and accuracy, the water level algorithm provided equal or better results compared to traditional water level probes in three different in situ configurations.

  1. Occurrence and sources of Escherichia coli in metropolitan St. Louis streams, October 2004 through September 2007

    Science.gov (United States)

    Wilkison, Donald H.; Davis, Jerri V.

    2010-01-01

    The occurrence and sources of Escherichia coli (E. coli), one of several fecal indicator bacteria, in metropolitan St. Louis streams known to receive nonpoint source runoff, occasional discharges from combined and sanitary sewers, and treated wastewater effluent were investigated from October 2004 through September 2007. Three Missouri River sites, five Mississippi River sites, and six small basin tributary stream sites were sampled during base flow and storm events for the presence of E. coli and their sources. E. coli host-source determinations were conducted using local library based genotypic methods. Human fecal contamination in stream samples was additionally confirmed by the presence of Bacteroides thetaiotaomicron, an anaerobic, enteric bacterium with a high occurrence in, and specificity to, humans. Missouri River E. coli densities and loads during base flow were approximately 10 times greater than those in the Mississippi River above its confluence with the Missouri River. Although substantial amounts of E. coli originated from within the study area during base flow and storm events, considerable amounts of E. coli in the Missouri River, as well as in the middle Mississippi River sections downstream from its confluence with the Missouri River, originated in Missouri River reaches upstream from the study area. In lower Mississippi River reaches, bacteria contributions from the numerous combined and sanitary sewer overflows within the study area, as well as contributions from nonpoint source runoff, greatly increased instream E. coli densities. Although other urban factors cannot be discounted, average E. coli densities in streams were strongly correlated with the number of upstream combined and sanitary sewer overflow points, and the percentage of upstream impervious cover. Small basin sites with the greatest number of combined and sanitary sewer overflows (Maline Creek and the River des Peres) had larger E. coli densities, larger loads, and a greater

  2. Combined sewer overflows impact on water quality and environmental ecosystem in the Harlem River

    Science.gov (United States)

    Wang, J.

    2017-12-01

    Combined sewer overflows (CSOs) discharge untreated sewage into the Harlem River during wet weather conditions, and it elevated nutrients and pathogen levels. It is not safe for swimming, fishing or boating especially in rainstorms. The Harlem River, a 9.3 mile long natural straight, connects the Hudson and East Rivers in New York City. It had been historically used for swimming, fishing, boating. Anthropogenic impacts have degraded water quality, limiting current aquatic activity in the river. CSOs water samples were collected during rainstorms, and analyzed in the laboratories of the Chemistry and Biology Department, Bronx Community College, City University of New York. Results showed elevated bacteria/pathogen and nutrient levels. Most recent data showed an ammonia concentration of 2.6 mg/L on July 30, 2015 during a heavy afternoon thunderstorm, and an ammonia level 2.7mg/L during tropical storm Arthur on July 2, 2014. Both significantly exceeded the EPA regulation level for NYC waters of 0.23mg/L. Phosphate levels peaked at 0.197 mg/L during a heavy thunderstorm on Apr 28, 2011, which was much higher than regulated level of 0.033 mg/L. Turbidity was 319 FAU during the July 30 2015 heavy thunderstorm, and was 882 FAU during tropical storm Arthur; which was significantly higher than regulation level of 5.25 FAU. CSOs collected during a recent heavy rainstorm on Oct 28, 2015, showed fecal coliform of 1 million MPN/100ml, E.Coli. of 60,000 MPN/100ml, and enterococcus of 65,000 MPN/100ml; which exceeded regulated levels of fecal coliform-200 MPN/100ml, E.Coli.-126 MPN/100ml, enterococcus-104 MPN/100ml. It is critical to reduce CSOs, restore ecosystem and improve water quality of the Harlem River. Green wall, green roof, and wetland had been used to reduce stormwater runoff & CSOs in the Bronx River; these green infrastructures are going to be used along the Harlem River waterfront as well. The goal of this research is to make the Harlem River swimmable and fishable

  3. The use of multiple tracers to evaluate the impact of sewered and non-sewered development on coastal water quality in a rural area of Florida.

    Science.gov (United States)

    Meeroff, Daniel E; Bloetscher, Frederick; Long, Sharon C; Bocca, Thais

    2014-05-01

    When onsite wastewater treatment and disposal systems (OSTDS) are not sited appropriately or installed properly, wastewater constituents can be a source of adverse environmental impacts to soil and groundwater, which can lead to potential public health risks. A paired monitoring design developed to compare water quality in sewered and non-sewered areas is presented here. It is suggested as a possible monitoring scheme for assessing the impact of sewer installation projects. As such, two sets of single-family, rural residential Florida neighborhoods were evaluated over a two-year period to gain insight into the effects of small-community use of OSTDS on coastal water quality. One set of two neighborhoods were connected to the sanitary sewer network and the other set of two were served exclusively by OSTDS. Water quality sampling was conducted at the paired sites during seasonal high water table (SHWT) and seasonal low water table (SLWT) events. Measured surface water quality during the SHWT showed indications of environmental impacts from OSTDS in terms of nutrients, microbial pathogen indicators, and other water quality measures, such as turbidity and conductivity. However, during the SLWT events, no obvious impacts attributable to OSTDS were detected. The water quality results indicate that OSTDS impacts may be measureable in rural areas. Other factors, such as microbial indicator survival and regrowth potential, may confound the understanding of water quality impacts of sewer projects. For example, the microbial indicators Escherichia coli and enterococci were found to persist over time and therefore did not always represent true comparisons of OSTDS and sewered areas between seasons. The timeframe for evaluating the effects of sewer projects may be longer than anticipated because of this survival and regrowth phenomenon.

  4. Biodegradability of organic matter associated with sewer sediments during first flush.

    Science.gov (United States)

    Sakrabani, Ruben; Vollertsen, Jes; Ashley, Richard M; Hvitved-Jacobsen, Thorkild

    2009-04-01

    The high pollution load in wastewater at the beginning of a rain event is commonly known to originate from the erosion of sewer sediments due to the increased flow rate under storm weather conditions. It is essential to characterize the biodegradability of organic matter during a storm event in order to quantify the effect it can have further downstream to the receiving water via discharges from Combined Sewer Overflow (CSO). The approach is to characterize the pollutograph during first flush. The pollutograph shows the variation in COD and TSS during a first flush event. These parameters measure the quantity of organic matter present. However these parameters do not indicate detailed information on the biodegradability of the organic matter. Such detailed knowledge can be obtained by dividing the total COD into fractions with different microbial properties. To do so oxygen uptake rate (OUR) measurements on batches of wastewater have shown itself to be a versatile technique. Together with a conceptual understanding of the microbial transformation taking place, OUR measurements lead to the desired fractionation of the COD. OUR results indicated that the highest biodegradability is associated with the initial part of a storm event. The information on physical and biological processes in the sewer can be used to better manage sediment in sewers which can otherwise result in depletion of dissolved oxygen in receiving waters via discharges from CSOs.

  5. Determining the spill flow discharge of combined sewer overflows using rating curves based on computational fluid dynamics instead of the standard weir equation.

    Science.gov (United States)

    Fach, S; Sitzenfrei, R; Rauch, W

    2009-01-01

    It is state of the art to evaluate and optimise sewer systems with urban drainage models. Since spill flow data is essential in the calibration process of conceptual models it is important to enhance the quality of such data. A wide spread approach is to calculate the spill flow volume by using standard weir equations together with measured water levels. However, these equations are only applicable to combined sewer overflow (CSO) structures, whose weir constructions correspond with the standard weir layout. The objective of this work is to outline an alternative approach to obtain spill flow discharge data based on measurements with a sonic depth finder. The idea is to determine the relation between water level and rate of spill flow by running a detailed 3D computational fluid dynamics (CFD) model. Two real world CSO structures have been chosen due to their complex structure, especially with respect to the weir construction. In a first step the simulation results were analysed to identify flow conditions for discrete steady states. It will be shown that the flow conditions in the CSO structure change after the spill flow pipe acts as a controlled outflow and therefore the spill flow discharge cannot be described with a standard weir equation. In a second step the CFD results will be used to derive rating curves which can be easily applied in everyday practice. Therefore the rating curves are developed on basis of the standard weir equation and the equation for orifice-type outlets. Because the intersection of both equations is not known, the coefficients of discharge are regressed from CFD simulation results. Furthermore, the regression of the CFD simulation results are compared with the one of the standard weir equation by using historic water levels and hydrographs generated with a hydrodynamic model. The uncertainties resulting of the wide spread use of the standard weir equation are demonstrated.

  6. Peracetic acid disinfection kinetics for combined sewer overflows: indicator organisms, antibiotic resistance genes, and microbial community.

    Science.gov (United States)

    Eramo, Alessia; Medina, William Morales; Fahrenfeld, Nicole L

    2017-01-01

    Combined sewer overflows (CSOs) degrade water quality and end-of-pipe treatment is one potential solution for retrofitting this outdated infrastructure. The goal of this research was to evaluate peracetic acid (PAA) as a disinfectant for CSOs using viability based molecular methods for antibiotic resistance genes (ARGs), indicator organism marker gene BacHum, and 16S rRNA genes. Simulated CSO effluent was prepared using 23-40% wastewater, representing the higher end of the range of wastewater concentrations reported in CSO effluent. PAA residual following disinfection was greatest for samples with the lowest initial COD. Treatment of simulated CSO effluent (23% wastewater) with 100 mg∙min/L PAA (5 mg/L PAA, 20 min) was needed to reduce viable cell sul 1, tet (G), and BacHum (1.0±0.63-3.2±0.25-log) while 25 to 50 mg•min/L PAA (5 mg/L PAA, 5-10 min) was needed to reduce viable cell loads (0.62±0.56-1.6±0.08-log) in 40% wastewater from a different municipal treatment plant. Increasing contact time after the initial decrease in viable cell gene copies did not significantly improve treatment. A much greater applied Ct of 1200 mg∙min/L PAA (20 mg/L PAA, 60 min) was required for significant log reduction of 16S rRNA genes (3.29±0.13-log). No significant losses of mex B were observed during the study. Data were fitted to a Chick-Watson model and resulting inactivation constants for sul 1 and tet (G) > BacHum > 16S rRNA. Amplicon sequencing of the 16S rRNA gene indicated the initial viable and total microbial communities were distinct and that treatment with PAA resulted in marked increases of the relative abundance of select phyla, particularly Clostridia which increased by 1-1.5 orders of magnitude. Results confirm that membrane disruption is a mechanism for PAA disinfection and further treatment is needed to reduce total ARGs in CSO effluent.

  7. Pollution loads from stormwater overflows

    International Nuclear Information System (INIS)

    Bonomo, L.

    1991-01-01

    The knowledge of the volume of combined effluents outflowing from overflows is not enough to allow a direct evaluation of polluting loads discharged into final receptors; the hypothesis of complete mixing between sewage and stormwater flow, fed in at a pollutant concentration level equal to zero, hasn't proved to be successful. The amount of the outflowing loads largely depends on the contamination of the stormwater runoff before inflow into the drainage system and on sedimentation and resuspension phenomena. This paper reports the main aspects connected with wet and dry atmospheric deposition of pollutants and with paved surface wash-out phenomena. The origin of pollutants flush, due to the resuspension and mass transport of polluting substances stored up in the sewer during draughts, is also described. Attention is drawn to the importance of the behaviour of the different pollutants with respect to the sedimentation phenomena. Reference is made to evaluations conducted on a drainage system for the recovery of a small pre-alpine lake

  8. Risk assessment of radionuclide discharges to sanitary sewers

    International Nuclear Information System (INIS)

    Galpin, F.L.; Merrell, G.; Rogers, V.C.

    1996-01-01

    This presentation describes the basic approach and conduct of a study of the possible risks and consequences of radionuclide discharges into a sewage treatment system. The study's objective was to determine if there were any possible significant exposures to either WSSC workers or the public form the discharge of radioactive material into the sewer system. The conduct of this study included a review of applicable regulations, and a case study of some past contamination events. The evaluation of potential occupational exposures involved measurements in the collection system were selected based on their location relative to potential dischargers. Measurement points at the treatment works were selected at points where biosolids might accumulate. Both passive, (TLD) and active, (scintillation detector) measurements were made. A limited number of samples were taken and analyzed. Potential doses to the public were estimated based on the possible pathways to man. Due both to limited resources and other project constraints several assumptions and bounding calculations were necessary to meet the objective. Although the study concluded that there were no present significant health concerns, followup evaluations were recommended. 7 refs., 1 fig., 1 tab

  9. Peracetic Acid as a Green Disinfectant for Combined Sewer ...

    Science.gov (United States)

    This cooperative research and development agreement between U.S. EPA, Solvay, MSDGC, and CB&I is evaluating the potential of PAA for disinfection of Muddy Creek CSO wastewater and comparing that with sodium hypochlorite disinfection. This presentation will document the effectiveness of sodium hypochlorite and PAA for the inactivation of E. coli in CSO wastewater using laboratory bench-scale jar tests and Muddy Creek field site studies based on the following items:•Storage, shelf life, and application of the disinfectants.•Effectiveness of the disinfectants in the inactivation of E. coli.•Formation of harmful byproducts by the disinfectants.•Operation and maintenance costs, including the cost of the disinfectant, its storage, application, and neutralizing agent for the disinfectant to maintain the Ohio EPA guideline for residual disinfectant at the discharge point. Like many cities in the USA, Cincinnati, Ohio is attempting to find the best way to meet state and federal requirements concerning combined sewer overflow (CSO) wastewater. The Muddy Creek CSO treatment facility was constructed to provide treatment for CSO Numbers 198 and 216 from the Westwood Trunk sewer. The Metropolitan Sewer District of Greater Cincinnati (MSDGC) is currently using sodium hypochlorite for disinfection in this treatment facility. Because of degradation of hypochlorite during storage and the formation of chlorinated disinfection byproducts (DBPs), MSDGC is evaluating alternat

  10. Reduction of bacteria and somatic coliphages in constructed wetlands for the treatment of combined sewer overflow (retention soil filters).

    Science.gov (United States)

    Ruppelt, Jan P; Tondera, Katharina; Schreiber, Christiane; Kistemann, Thomas; Pinnekamp, Johannes

    2018-05-01

    Combined sewer overflows (CSOs) introduce numerous pathogens from fecal contamination, such as bacteria and viruses, into surface waters, thus endangering human health. In Germany, retention soil filters (RSFs) treat CSOs at sensitive discharge points and can contribute to reducing these hygienically relevant microorganisms. In this study, we evaluated the extent of how dry period, series connection and filter layer thickness influence the reduction efficiency of RSFs for Escherichia coli (E. coli), intestinal enterococci (I. E.) and somatic coliphages. To accomplish this, we had four pilot scale RSFs built on a test field at the wastewater treatment plant Aachen-Soers. While two filters were replicates, the other two filters were installed in a series connection. Moreover, one filter had a thinner filtration layer than the other three. Between April 2015 and December 2016, the RSFs were loaded in 37 trials with pre-conditioned CSO after dry periods ranging from 4 to 40 days. During 17 trials, samples for microbial analysis were taken and analyzed. The series connection of two filters showed that the removal increases when two systems with a filter layer of the same height are operated in series. Since the microorganisms are exposed twice to the environmental conditions on the filter surface and in the upper filter layers, there is a greater chance for abiotic adsorption increase. The same effect could be shown when filters with different depths were compared: the removal efficiency increases as filter thickness increases. This study provides new evidence that regardless of seasonal effects and dry period, RSFs can improve hygienic situation significantly. Copyright © 2018 Elsevier GmbH. All rights reserved.

  11. The distribution dynamics and desorption behaviour of mobile pharmaceuticals and caffeine to combined sewer sediments.

    Science.gov (United States)

    Hajj-Mohamad, M; Darwano, H; Duy, S Vo; Sauvé, S; Prévost, M; Arp, H P H; Dorner, S

    2017-01-01

    Pharmaceuticals are discharged to the environment from wastewater resource recovery facilities, sewer overflows, and illicit sewer connections. To understand the fate of pharmaceuticals, there is a need to better understand their sorption dynamics to suspended sediments (SS) and settled sediments (StS) in sewer systems. In this study, such sorption dynamics to both SS and StS were assessed using a batch equilibrium method under both static and dynamic conditions. Experiments were performed with natively occurring and artificially modified concentrations of sewer pharmaceuticals (acetaminophen, theophylline, carbamazepine, and a metabolite of carbamazepine) and caffeine. Differences in apparent distribution coefficients, K d,app , between SS and StS were related to differences in their organic carbon (OC) content, and the practice of artificially modifying the concentration. K d,app values of modified contaminant concentrations and high OC sediments were substantially higher. Pseudo-second order desorption rates for these mobile compounds were also quantified. Successive flushing events to simulate the addition of stormwater to sewer networks revealed that aqueous concentrations would not necessarily decrease, because the added water will rapidly return to equilibrium concentrations with the sediments. Sorption and desorption kinetics must be considered in addition to dilution, to avoid underestimating the influence of dilution on concentrations of pharmaceuticals discharged to the environment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Cesium and strontium loads into a combined sewer system from rainwater runoff.

    Science.gov (United States)

    Kamei-Ishikawa, Nao; Yoshida, Daiki; Ito, Ayumi; Umita, Teruyuki

    2016-12-01

    In this study, combined sewage samples were taken with time in several rain events and sanitary sewage samples were taken with time in dry weather to calculate Cs and Sr loads to sewers from rainwater runoff. Cs and Sr in rainwater were present as particulate forms at first flush and the particulate Cs and Sr were mainly bound with inorganic suspended solids such as clay minerals in combined sewage samples. In addition, multiple linear regression analysis showed Cs and Sr loads from rainwater runoff could be estimated by the total amount of rainfall and antecedent dry weather days. The variation of the Sr load from rainwater to sewers was more sensitive to total amount of rainfall and antecedent dry weather days than that of the Cs load. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Stochastic rainfall-runoff forecasting: parameter estimation, multi-step prediction, and evaluation of overflow risk

    DEFF Research Database (Denmark)

    Löwe, Roland; Mikkelsen, Peter Steen; Madsen, Henrik

    2014-01-01

    Probabilistic runoff forecasts generated by stochastic greybox models can be notably useful for the improvement of the decision-making process in real-time control setups for urban drainage systems because the prediction risk relationships in these systems are often highly nonlinear. To date...... the identification of models for cases with noisy in-sewer observations. For the prediction of the overflow risk, no improvement was demonstrated through the application of stochastic forecasts instead of point predictions, although this result is thought to be caused by the notably simplified setup used...

  14. Trace element carriers in combined sewer during dry and wet weather: an electron microscope investigation.

    Science.gov (United States)

    El Samrani, A G; Lartiges, B S; Ghanbaja, J; Yvon, J; Kohler, A

    2004-04-01

    The nature of trace element carriers contained in sewage and combined sewer overflow (CSO) was investigated by TEM-EDX-Electron diffraction and SEM-EDX. During dry weather, chalcophile elements were found to accumulate in sewer sediments as early diagenetic sulfide phases. The sulfurization of some metal alloys was also evidenced. Other heavy metal carriers detected in sewage include metal alloys, some iron oxihydroxide phases and neoformed phosphate minerals such as anapaite. During rain events, the detailed characterization of individual mineral species allowed to differentiate the contributions from various specific sources. Metal plating particles, barite from automobile brake, or rare earth oxides from catalytic exhaust pipes, originate from road runoff, whereas PbSn alloys and lead carbonates are attributed to zinc-works from roofs and paint from building siding. Soil contribution can be traced by the presence of clay minerals, iron oxihydroxides, zircons and rare earth phosphates. However, the most abundant heavy metal carriers in CSO samples were the sulfide particles eroded from sewer sediments. The evolution of relative abundances of trace element carriers during a single storm event, suggests that the pollution due to the "first flush" effect principally results from the sewer stock of sulfides and previously deposited metal alloys, rather than from urban surface runoff.

  15. Physical and Chemical Characterization of Fat and Oil Deposits in Mashhad City Sewer Lines and the Solutions Developed

    Directory of Open Access Journals (Sweden)

    Mahdi kamali

    2017-01-01

    Full Text Available Formation of oil, fat, and grease deposits in sewer pipelines is a major concern as they result in sewage overflow and pose health problems. Analysis of two sample deposits collected from the sewer lines of Imam Reza Street in the city of Mashhad suggested that the chemical reactions promoted by edible oils in the sewer lines lead to the formation of insoluble soap and deposits. Being sticky, the deposits accumulate over time to eventually block the lines. The analysis also showed that the moisture content of the samples ranged between 50‒62%, indicating that water does not play a main role in their formation. The samples were also found to contain 61.78% and 84.35% saturated fatty acids, with palmitic acid being the dominant one. Calcium was the main metal in the samples, which is due to both water hardness and corrosion of the sewer lines. Based on the results obtained, the origin of these deposits, and the relevant protocols for the management of oil and fat wastes, solutions were proposed to prevent deposit formation and sewer line clogging that suit the special cultural and environmental conditions of the city. These proposals are under consideration for implementation in the region.

  16. Sewer Processes

    DEFF Research Database (Denmark)

    Hvitved-Jacobsen, Thorkild; Vollertsen, Jes; Nielsen, Asbjørn Haaning

    Since the first edition was published over a decade ago, advancements have been made in the design, operation, and maintenance of sewer systems, and new problems have emerged. For example, sewer processes are now integrated in computer models, and simultaneously, odor and corrosion problems caused...... by hydrogen sulfide and other volatile organic compounds, as well as other potential health issues, have caused environmental concerns to rise. Reflecting the most current developments, Sewer Processes: Microbial and Chemical Process Engineering of Sewer Networks, Second Edition, offers the reader updated...... and valuable information on the sewer as a chemical and biological reactor. It focuses on how to predict critical impacts and control adverse effects. It also provides an integrated description of sewer processes in modeling terms. This second edition is full of illustrative examples and figures, includes...

  17. Physico-chemical characterization of grease interceptors with and without biological product addition.

    Science.gov (United States)

    He, Xia; Osborne, Jason; de los Reyes, Francis L

    2012-03-01

    Hardened and insoluble fat, oil, and grease (FOG) deposits are the primary cause of sewer line blockages leading to sanitary sewer overflows (SSOs). However, there have been very few long-term assessments of the physico-chemical characteristics of full-scale grease interceptors (GIs), the first "line of defense" against FOG buildup in sewer lines. In this study, we assessed the physico-chemical characteristics of two full-scale GIs (at a restaurant and a retirement community kitchen) over a one-year period. Statistically significant differences between bioaugmented and untreated cycles were detected for several chemical and physical properties. The treated cycles had lower BOD and COD at the grease interceptor outlet. While the combined data for all treated cycles did not show lower FOG concentrations in the GI outlet compared to the combined data for all untreated cycles, comparison of specific individual treated and untreated cycles show a positive effect due to the addition of product.

  18. Fat, oil and grease deposits in sewers: characterisation of deposits and formation mechanisms.

    Science.gov (United States)

    Williams, J B; Clarkson, C; Mant, C; Drinkwater, A; May, E

    2012-12-01

    Fat, oil and grease deposits (FOG) in sewers are a major problem and can cause sewer overflows, resulting in environmental damage and health risks. Often simplistically portrayed as cooling of fats, recent research has suggested that saponification may be involved in FOG formation. However there are still questions about the mechanisms effecting transformations in sewers and the role and source of metal cations involved in saponification. This study characterises FOG deposits from pumping stations, sewers and sewage works from different water hardness zones across the UK. The sites all had previous problems with FOG and most catchments contained catering and food preparation establishments. The FOG deposits were highly variable with moisture content ranging from 15 to 95% and oil content from 0 to 548 mg/g. Generally the pumping stations had lower moisture content and higher fat content, followed by the sewers then the sewage works. The water in contact with the FOG had high levels of oil (mean of about 800 mg/L) and this may indicate poor kitchen FOG management practices. FOG fatty acid profiles showed a transformation from unsaturated to saturated forms compared to typical cooking oils. This seems to relate to ageing in the sewer network or the mechanism of formation, as samples from pumping stations had higher proportions of C18:1 compared to C16. This may be due to microbial transformations by bacteria such as Clostridium sp. in a similar process to adipocere formation. There was an association between water hardness and increased Ca levels in FOG along with harder deposits and higher melting points. A link between FOG properties and water hardness has not been previously reported for field samples. This may also be due to microbial processes, such as biocalcification. By developing the understanding of these mechanisms it may be possible to more effectively control FOG deposits, especially when combined with promotion of behavioural change. Copyright © 2012

  19. Preparing for CMOM: challenges, opportunities and new approaches?

    International Nuclear Information System (INIS)

    Moore, G.T.; Morris, C.D.

    2002-01-01

    This paper will address the various aspects of the Sanitary Sewer Overflow (SSO) rule as it affects MSD and possibly other agencies / operators and municipalities with a focus on a new tool for estimating rainfall dependent inflow and infiltration (RDII). The statistical analysis will identify the principal factors that influence RDII such that they can be incorporated into the modeling and design efforts of relief or replacement sewers in a quantifiable manner. The method employed is a statistical model approach to predict RDII at any point in a collection system when applied to the principal sewershed characteristics. The model has stochastic and regression features in establishing RDII in a collection system when adequate resources are not available. With this model, the objective is to provide planners and designers with a tool to better estimate the RDII volumes, flows, and physical causes of excessive stormwater in a sanitary collection system. The United States Environmental Protection Agency (US EPA) is proposing in the new SSO rule comprehensive strategies in order to improve water quality from point source discharges. The SSO rule will require owners of the sanitary collection system to exercise decision-making skills so that the utility, agency or municipality will be in the best position possible to comply with the rule. These decisions will have significant impacts in both the near and far terms in regards to resources required from the local, state and federal governments and citizens. The SSO rule has four themes that will need to be a part of the owner's strategic approach: 1. Capacity Assurance, Management, Operations and Maintenance (CMOM) program; 2. A management approach for each sewershed or treatment area; 3. Prohibition provision for overflows. 4. Public notification, reporting and record keeping requirements. (author)

  20. Planning solutions of sanitary facilities in modern residential buildings

    Directory of Open Access Journals (Sweden)

    Orlov Evgeniy Vladimirovich

    2015-01-01

    Full Text Available In the article the short historical review on the design of sanitary rooms and their configurations is given. The main errors of the recent years, which led to the decrease in accommodation convenience because of the wrong approach from both the architect and engineers, are given. It is possible to use a small useful area for sanitary facilities, but it is connected with the lack of possibility of connecting washing and dishwashers. The author considers the options of engineering equipment placement in sanitary rooms taking into account the convenience of use, safety, and also resource-saving aspect. Various solutions on the organization of heating and ventilation are provided. The possible technical solutions allowing solving a flooding problem of the first floors in elite housing estates in case of accident are offered with the help of full waterproofing of sanitary rooms, and also the whole area of the apartment. The main attention was focused on the improvements of sanitary rooms for one-room and two-room apartments, which are the most demanded in the modern market of real estate. Layout solutions of the reduced bathrooms on the placement of the necessary equipment with choice justification are provided. The attention is paid to the layout solution for modern kitchens on order to increase their comfort by the use of special two-section sinks, and also a grinder of food waste in order to allow to lower the load of the systems of rubbish disposal of a building, by dumping the crushed garbage in an internal sewer network. Various options of evolutionary development of sanitary rooms for increasing the comfort degree are given. First of all, the development should happen in the direction of not only sanitation and hygiene, but also of the maintenance of the physical health of the people living in the building. It can be carried out by increase in a useful area of sanitary rooms, installation of exercise machines, medical bathtubs and a Jacuzzi

  1. Green-blue water in the city: quantification of impact of source control versus end-of-pipe solutions on sewer and river floods.

    Science.gov (United States)

    De Vleeschauwer, K; Weustenraad, J; Nolf, C; Wolfs, V; De Meulder, B; Shannon, K; Willems, P

    2014-01-01

    Urbanization and climate change trends put strong pressures on urban water systems. Temporal variations in rainfall, runoff and water availability increase, and need to be compensated for by innovative adaptation strategies. One of these is stormwater retention and infiltration in open and/or green spaces in the city (blue-green water integration). This study evaluated the efficiency of three adaptation strategies for the city of Turnhout in Belgium, namely source control as a result of blue-green water integration, retention basins located downstream of the stormwater sewers, and end-of-pipe solutions based on river flood control reservoirs. The efficiency of these options is quantified by the reduction in sewer and river flood frequencies and volumes, and sewer overflow volumes. This is done by means of long-term simulations (100-year rainfall simulations) using an integrated conceptual sewer-river model calibrated to full hydrodynamic sewer and river models. Results show that combining open, green zones in the city with stormwater retention and infiltration for only 1% of the total city runoff area would lead to a 30 to 50% reduction in sewer flood volumes for return periods in the range 10-100 years. This is due to the additional surface storage and infiltration and consequent reduction in urban runoff. However, the impact of this source control option on downstream river floods is limited. Stormwater retention downstream of the sewer system gives a strong reduction in peak discharges to the receiving river. However due to the difference in response time between the sewer and river systems, this does not lead to a strong reduction in river flood frequency. The paper shows the importance of improving the interface between urban design and water management, and between sewer and river flood management.

  2. DESIGN AND TECHNOLOGICAL SOLUTIONS FOR THE RESTORATION OF SEWERS USING ELEMENTS OF RECYCLED POLYMER COMPOSITE MATERIALS

    Directory of Open Access Journals (Sweden)

    GONCHARENKO D. F.

    2017-01-01

    Full Text Available Problem statement. Currently sanitary drainage systems of large cities in Ukraine are significantly worn down with prolonged use and due to inefficient solutions for protection of the structures from aggressive effects of the environment, poor quality of materials and construction and installation works during building. Restoration of performance characteristics, reliability and durability of sewer tunnels is the costly and technically complex task, which is urgently needed to be fulfilled to prevent accidents including those with serious environmental impact. Modern work technique and the materials used for restoration allow us to solve these problems with different levels of efficiency, while reducing the cost of restoration due to use of recycled polymeric raw material, as well as to improvement of technological solutions is a currently important direction of research. Purpose of the article. To develop solutions for restoring serviceability, reliability and durability of sewer tunnels taking into account the accumulated experience in renovation of water disposal networks. Conclusion. Use of components made of recycled polymer composite materials during restoring sewer tunnels has significant economic and environmental effects and allows to undertake repair work in hard-to-reach areas.

  3. Resilience of sewage services to climate change uncertainty: analysis of the management of sewer overflows in two Parisian suburban areas.

    Science.gov (United States)

    Rioust, E.; Deroubaix, J. F.; Barroca, B.; Bonierbale, T.; de Gouvello, B.; Deutsch, J. C.; Hubert, G.

    2009-04-01

    This paper considers the resilience perspective as an approach for understanding social and political vulnerabilities of urban services. The authors examine to what extend uncertainty due to climate change may affect the resilience of these urban services. The resilience perspective is increasingly used for analysing social groups' capacities to adapt to and live with disturbances. A lot of work on resilience has focused on the capacity to absorb shocks and still maintain functions. But there is also another aspect of resilience, which leads to take into account systems vulnerabilities and to aim at understanding their equilibrium and re-organization capacity. The purpose with this paper is to assess sewage systems capacities to adapt to climate change. Indeed, climate change could cause an increase of extreme rain events and, as a matter of consequence, an increase of sewer overflows and flooding of urbanised areas. Sewer systems have to cope with this change that may gravely affect urban planning. In recent studies of political science, risk management has been considered as a public policy involving and resulting from complex social, political and technical processes (Gilbert et al. 2003). From this point of view, the management of wastewaters and storm waters has to be considered not only as a technical but also as a political and a social system. Therefore, political science can be a fruitful perspective to understand the stakeholders perceptions of uncertainty and the way they are going to integrate this issue in their practices. The authors analyse the adaptive capacities of two sewer systems located in the Parisian suburban area. The chosen areas are highly populated. Each network is managed within a political and administrative unit called "Département". Both authorities of these "Départements" implement a public sewage service. Nonetheless these networks are connected and part of the greater Paris sewage policy. In both areas a real time control of

  4. Quantifying fat, oil, and grease deposit formation kinetics.

    Science.gov (United States)

    Iasmin, Mahbuba; Dean, Lisa O; Ducoste, Joel J

    2016-01-01

    Fat, oil, and grease (FOG) deposits formed in sanitary sewers are calcium-based saponified solids that are responsible for a significant number of nationwide sanitary sewer overflows (SSOs) across United States. In the current study, the kinetics of lab-based saponified solids were determined to understand the kinetics of FOG deposit formation in sewers for two types of fat (Canola and Beef Tallow) and two types of calcium sources (calcium chloride and calcium sulfate) under three pH (7 ± 0.5, 10 ± 0.5, and ≈14) and two temperature conditions (22 ± 0.5 and 45 ± 0.5 °C). The results of this study displayed quick reactions of a fraction of fats with calcium ions to form calcium based saponified solids. Results further showed that increased palmitic fatty acid content in source fats, the magnitude of the pH, and temperature significantly affect the FOG deposit formation and saponification rates. The experimental data of the kinetics were compared with two empirical models: a) Cotte saponification model and b) Foubert crystallization model and a mass-action based mechanistic model that included alkali driven hydrolysis of triglycerides. Results showed that the mass action based mechanistic model was able to predict changes in the rate of formation of saponified solids under the different experimental conditions compared to both empirical models. The mass-action based saponification model also revealed that the hydrolysis of Beef Tallow was slower compared to liquid Canola fat resulting in smaller quantities of saponified solids. This mechanistic saponification model, with its ability to track the saponified solids chemical precursors, may provide an initial framework to predict the spatial formation of FOG deposits in municipal sewers using system wide sewer collection modeling software. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Research note: Mapping spatial patterns in sewer age, material, and proximity to surface waterways to infer sewer leakage hotspots

    Science.gov (United States)

    Hopkins, Kristina G.; Bain, Daniel J.

    2018-01-01

    Identifying areas where deteriorating sewer infrastructure is in close proximity to surface waterways is needed to map likely connections between sewers and streams. We present a method to estimate sewer installation year and deterioration status using historical maps of the sewer network, parcel-scale property assessment data, and pipe material. Areas where streams were likely buried into the sewer system were mapped by intersecting the historical stream network derived from a 10-m resolution digital elevation model with sewer pipe locations. Potential sewer leakage hotspots were mapped by identifying where aging sewer pipes are in close proximity (50-m) to surface waterways. Results from Pittsburgh, Pennsylvania (USA), indicated 41% of the historical stream length was lost or buried and the potential interface between sewers and streams is great. The co-location of aging sewer infrastructure (>75 years old) near stream channels suggests that 42% of existing streams are located in areas with a high potential for sewer leakage if sewer infrastructure fails. Mapping the sewer-stream interface provides an approach to better understand areas were failing sewers may contribute a disproportional amount of nutrients and other pathogens to surface waterways.

  6. Hydrodynamic modelling of the influence of stormwater and combined sewer overflows on receiving water quality: Benzo(a)pyrene and copper risks to recreational water.

    Science.gov (United States)

    Björklund, Karin; Bondelind, Mia; Karlsson, Anna; Karlsson, Dick; Sokolova, Ekaterina

    2018-02-01

    The risk from chemical substances in surface waters is often increased during wet weather, due to surface runoff, combined sewer overflows (CSOs) and erosion of contaminated land. There are strong incentives to improve the quality of surface waters affected by human activities, not only from ecotoxicity and ecosystem health perspectives, but also for drinking water and recreational purposes. The aim of this study is to investigate the influence of urban stormwater discharges and CSOs on receiving water in the context of chemical health risks and recreational water quality. Transport of copper (Cu) and benzo[a]pyrene (BaP) in the Göta River (Sweden) was simulated using a hydrodynamic model. Within the 16 km modelled section, 35 CSO and 16 urban stormwater point discharges, as well as the effluent from a major wastewater treatment plant, were included. Pollutant concentrations in the river were simulated for two rain events and investigated at 13 suggested bathing sites. The simulations indicate that water quality guideline values for Cu are exceeded at several sites, and that stormwater discharges generally give rise to higher Cu and BaP concentrations than CSOs. Due to the location of point discharges and the river current inhibiting lateral mixing, the north shore of the river is better suited for bathing. Peak concentrations have a short duration; increased concentrations of the pollutants may however be present for several days after a rain event. Monitoring of river water quality indicates that simulated Cu and BaP concentrations are in the same order of magnitude as measured concentrations. It is concluded that hydrodynamic modelling is a useful tool for identifying suitable bathing sites in urban surface waters and areas of concern where mitigation measures should be implemented to improve water quality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Environmental Assessment for Alternate Water Supply System, Joint Base Langley-Eustis, Newport News, Virginia

    Science.gov (United States)

    2013-06-01

    sanitary sewer facilities at JBLE- FE. The existing water distribution system consists of approximately 50 miles of pipe, a water booster pumping station...layers consist of clay , silty clay , or silty clay loam. None of these soils are classified as Prime Farmland soils. Environmental Assessment for...ODUS owns and operates the sanitary sewer facilities at JBLE-FE. Newport News owns and operates the sanitary sewer facilities on the private land in

  8. City sewer collectors biocorrosion

    Science.gov (United States)

    Ksiażek, Mariusz

    2014-12-01

    This paper presents the biocorrosion of city sewer collectors impregnated with special polymer sulphur binders, polymerized sulphur, which is applied as the industrial waste material. The city sewer collectors are settled with a colony of soil bacteria which have corrosive effects on its structure. Chemoautotrophic nitrifying bacteria utilize the residues of halites (carbamide) which migrate in the city sewer collectors, due to the damaged dampproofing of the roadway and produce nitrogen salts. Chemoorganotrophic bacteria utilize the traces of organic substrates and produce a number of organic acids (formic, acetic, propionic, citric, oxalic and other). The activity of microorganisms so enables the origination of primary and secondary salts which affect physical properties of concretes in city sewer collectors unfavourably.

  9. Probabilistic modelling of overflow, surcharge and flooding in urban drainage using the first-order reliability method and parameterization of local rain series

    DEFF Research Database (Denmark)

    Thorndahl, Søren; Willems, Patrick

    2007-01-01

    Failure of urban drainage systems may occur due to surcharge or flooding at specific manholes in the system, or due to overflows from combined sewer systems to receiving waters. To quantify the probability or return period of failure, standard approaches make use of the simulation of design storms...... or long historical rainfall series in a hydrodynamic model of the urban drainage system. In this paper, an alternative probabilistic method is investigated: the First Order Reliability Method (FORM). To apply this method, a long rainfall time series was divided in rain storms (rain events), and each rain...

  10. Management of storm water in unitary sewer systems; Gestion de las aguas de tormenta en las redes de alcantarillado unitarias

    Energy Technology Data Exchange (ETDEWEB)

    Rayos, C.

    1999-08-01

    A brief review is provided of the general problems of storm waters and how they are dealt with in Directive 91/27/EEC. An experiment in Asturias, Spain, is reported in which storm water storage tanks were designed to reduce the number and impact of discharges from the unitary sewer systems. The criteria for calculating the design flows in accordance with the guidelines of Spain`s Northern Hydrographic Confederation, the procedures used in determining the size of the overflows and the different elements employed in the equipment, control systems and safety systems are all described. (Author) 31 refs.

  11. Finding of No Significant Impact: Proposed Bank Stabilization Tennessee River River Mile 466.2 - 466.5, Hamilton County, Tennessee

    Science.gov (United States)

    2013-05-02

    Bank erosion is endangering approximately 1,100 feet of a 42-inch concrete gravity sanitary main, two manholes, and a 30-inch iron sanitary sewer...stabilizing the bank. Kingfisher nests are excavated burrows with bare soil along stream banks (USACE, 2009). “Banks with a high content of clay , gravel, or...34’ g -- - -- - - ---- --- -------- 1 LEGEND ESTIMATED 42’’ GRAVITY SEWER LINE ESTIMATED 30’’ FORCE MAIN ® SANITARY SEWER MANHOLE • AUTO

  12. 300 Area process sewer piping upgrade and 300 Area treated effluent disposal facility discharge to the City of Richland Sewage System, Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    The U.S. Department of Energy (DOE) is proposing to upgrade the existing 300 Area Process Sewer System by constructing and operating a new process sewer collection system that would discharge to the 300 Area Treated Effluent Disposal Facility. The DOE is also considering the construction of a tie-line from the TEDF to the 300 Area Sanitary Sewer for discharging the process wastewater to the City of Richland Sewage System. The proposed action is needed because the integrity of the old piping in the existing 300 Area Process Sewer System is questionable and effluents might be entering the soil column from leaking pipes. In addition, the DOE has identified a need to reduce anticipated operating costs at the new TEDF. The 300 Area Process Sewer Piping Upgrade (Project L-070) is estimated to cost approximately $9.9 million. The proposed work would involve the construction and operation of a new process sewer collection system. The new system would discharge the effluents to a collection sump and lift station for the TEDF. The TEDF is designed to treat and discharge the process effluent to the Columbia River. The process waste liquid effluent is currently well below the DOE requirements for radiological secondary containment and is not considered a RCRA hazardous waste or a State of Washington Hazardous Waste Management Act dangerous waste. A National Pollutant Discharge Elimination, System (NPDES) permit has been obtained from the U.S. Environmental Protection Agency for discharge to the Columbia River. The proposed action would upgrade the existing 300 Area Process Sewer System by the construction and operation of a new combined gravity, vacuum, and pressurized process sewer collection system consisting of vacuum collection sumps, pressure pump stations, and buried polyvinyl chloride or similar pipe. Two buildings would also be built to house a main collection station and a satellite collection station.

  13. Time series modelling of overflow structures

    DEFF Research Database (Denmark)

    Carstensen, J.; Harremoës, P.

    1997-01-01

    The dynamics of a storage pipe is examined using a grey-box model based on on-line measured data. The grey-box modelling approach uses a combination of physically-based and empirical terms in the model formulation. The model provides an on-line state estimate of the overflows, pumping capacities...... and available storage capacity in the pipe as well as predictions of future states. A linear overflow relation is found, differing significantly from the traditional modelling approach. This is due to complicated overflow structures in a hydraulic sense where the overflow is governed by inertia from the inflow...... to the overflow structures. The capacity of a pump draining the storage pipe has been estimated for two rain events, revealing that the pump was malfunctioning during the first rain event. The grey-box modelling approach is applicable for automated on-line surveillance and control. (C) 1997 IAWQ. Published...

  14. A buffer overflow detection based on inequalities solution

    International Nuclear Information System (INIS)

    Xu Guoai; Zhang Miao; Yang Yixian

    2007-01-01

    A new buffer overflow detection model based on Inequalities Solution was designed, which is based on analyzing disadvantage of the old buffer overflow detection technique and successfully converting buffer overflow detection to Inequalities Solution. The new model can conquer the disadvantage of the old technique and improve efficiency of buffer overflow detection. (authors)

  15. Overflow Concentration and Sedimentation in Hoppers

    DEFF Research Database (Denmark)

    Hjelmager Jensen, Jacob; Saremi, Sina

    2014-01-01

    Sediment spillage from hopper overflow constitutes a source for sediment plumes and can also impact the turbidity of aquatic environments. The overflowing mixture is often different from the mixture pumped into the hopper (the inflow), because the mixture undergoes compositional transformation...... as a result of different timescales in the segregation of the various sediment fractions. The heavier constituents in a mixture will have had time to settle, and overflowing sediments are therefore primarily composed of the finer and lighter constituents, whose concentrations potentially exceed those...... sediment mixtures (i.e., polydispersions). Strictly speaking, these formulas have been validated for homogeneous and unenergetic mixtures only, but the hopper system fulfills these criteria reasonably well. A proper description of the compositional transformation during filling and subsequent overflow...

  16. Buffer Overflow Period in a MAP Queue

    Directory of Open Access Journals (Sweden)

    Andrzej Chydzinski

    2007-01-01

    Full Text Available The buffer overflow period in a queue with Markovian arrival process (MAP and general service time distribution is investigated. The results include distribution of the overflow period in transient and stationary regimes and the distribution of the number of cells lost during the overflow interval. All theorems are illustrated via numerical calculations.

  17. Water quality in the Mahoning River and selected tributaries in Youngstown, Ohio

    Science.gov (United States)

    Stoeckel, Donald M.; Covert, S. Alex

    2002-01-01

    The lower reaches of the Mahoning River in Youngstown, Ohio, have been characterized by the Ohio Environmental Protection Agency (OEPA) as historically having poor water quality. Most wastewater-treatment plants (WWTPs) in the watershed did not provide secondary sewage treatment until the late 1980s. By the late 1990s, the Mahoning River still received sewer-overflow discharges from 101 locations within the city of Youngstown, Ohio. The Mahoning River in Youngstown and Mill Creek, a principal tributary to the Mahoning River in Youngstown, have not met biotic index criteria since the earliest published assessment by OEPA in 1980. Youngstown and the OEPA are working together toward the goal of meeting water-quality standards in the Mahoning River. The U.S. Geological Survey collected information to help both parties assess water quality in the area of Youngstown and to estimate bacteria and inorganic nitrogen contributions from sewer-overflow discharges to the Mahoning River. Two monitoring networks were established in the lower Mahoning River: the first to evaluate hydrology and microbiological and chemical water quality and the second to assess indices of fish and aquatic-macroinvertebrate-community health. Water samples and water-quality data were collected from May through October 1999 and 2000 to evaluate where, when, and for how long water quality was affected by sewer-overflow discharges. Water samples were collected during dry- and wet-weather flow, and biotic indices were assessed during the first year (1999). The second year of sample collection (2000) was directed toward evaluating changes in water quality during wet-weather flow, and specifically toward assessing the effect of sewer-overflow discharges on water quality in the monitoring network. Water-quality standards for Escherichia coli (E. coli) concentration and draft criteria for nitrate plus nitrite and total phosphorus were the regulations most commonly exceeded in the Mahoning River and Mill

  18. Interger multiplication with overflow detection or saturation

    Energy Technology Data Exchange (ETDEWEB)

    Schulte, M.J.; Balzola, P.I.; Akkas, A.; Brocato, R.W.

    2000-01-11

    High-speed multiplication is frequently used in general-purpose and application-specific computer systems. These systems often support integer multiplication, where two n-bit integers are multiplied to produce a 2n-bit product. To prevent growth in word length, processors typically return the n least significant bits of the product and a flag that indicates whether or not overflow has occurred. Alternatively, some processors saturate results that overflow to the most positive or most negative representable number. This paper presents efficient methods for performing unsigned or two's complement integer multiplication with overflow detection or saturation. These methods have significantly less area and delay than conventional methods for integer multiplication with overflow detection and saturation.

  19. Tertiary Treatment and Recycling of Wastewater

    Science.gov (United States)

    2015-05-18

    of the Worrell design (Figure 2.1) illustrates the modular treatment cells filled with vitrified expanded clay (or similar media) and planted with...General Construction Storm Water permit Sanitary / Storm Drainage Restriction: Absolutely no materials are to be disposed of via the sanitary ...sewer or storm water systems without consulting the Environmental Office. Exception: Water may be discharged down the sanitary sewer when:  The

  20. Predicting concrete corrosion of sewers using artificial neural network.

    Science.gov (United States)

    Jiang, Guangming; Keller, Jurg; Bond, Philip L; Yuan, Zhiguo

    2016-04-01

    Corrosion is often a major failure mechanism for concrete sewers and under such circumstances the sewer service life is largely determined by the progression of microbially induced concrete corrosion. The modelling of sewer processes has become possible due to the improved understanding of in-sewer transformation. Recent systematic studies about the correlation between the corrosion processes and sewer environment factors should be utilized to improve the prediction capability of service life by sewer models. This paper presents an artificial neural network (ANN)-based approach for modelling the concrete corrosion processes in sewers. The approach included predicting the time for the corrosion to initiate and then predicting the corrosion rate after the initiation period. The ANN model was trained and validated with long-term (4.5 years) corrosion data obtained in laboratory corrosion chambers, and further verified with field measurements in real sewers across Australia. The trained model estimated the corrosion initiation time and corrosion rates very close to those measured in Australian sewers. The ANN model performed better than a multiple regression model also developed on the same dataset. Additionally, the ANN model can serve as a prediction framework for sewer service life, which can be progressively improved and expanded by including corrosion rates measured in different sewer conditions. Furthermore, the proposed methodology holds promise to facilitate the construction of analytical models associated with corrosion processes of concrete sewers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Sanitary survey of the drinking water supply of Kombinati suburb-Tirana, Albania.

    Science.gov (United States)

    Angjeli, V; Reme, B; Leno, L; Bukli, R; Bushati, G

    2000-01-01

    Microbiological pollution of drinking water is a major health problem in the suburbs of the Albanian capital. Intermittent supply and contamination, resulting in several gastrointestinal manifestations, are the main concerns for the population and health workers. The risk of outbreaks of water-borne diseases is high. Pollution originates from contamination of drinking water with domestic sewage. This research investigated the drinking water cycle from its natural source to the consumer, analysing samples and verifying pollution levels in the microbiological and chemical setting. The most important pollution sources were found in the distribution network, due to cross-contamination with sewers and illegal connections. The second pollution source was found around the extraction wells. This is related to abusive constructions within the sanitary zone around the wells and maybe the highly sewage-contaminated river water which feeds the aquifer.

  2. Consequential environmental and economic life cycle assessment of green and gray stormwater infrastructures for combined sewer systems.

    Science.gov (United States)

    Wang, Ranran; Eckelman, Matthew J; Zimmerman, Julie B

    2013-10-01

    A consequential life cycle assessment (LCA) is conducted to evaluate the trade-offs between water quality improvements and the incremental climate, resource, and economic costs of implementing green (bioretention basin, green roof, and permeable pavement) versus gray (municipal separate stormwater sewer systems, MS4) alternatives of stormwater infrastructure expansions against a baseline combined sewer system with combined sewer overflows in a typical Northeast US watershed for typical, dry, and wet years. Results show that bioretention basins can achieve water quality improvement goals (e.g., mitigating freshwater eutrophication) for the least climate and economic costs of 61 kg CO2 eq. and $98 per kg P eq. reduction, respectively. MS4 demonstrates the minimum life cycle fossil energy use of 42 kg oil eq. per kg P eq. reduction. When integrated with the expansion in stormwater infrastructure, implementation of advanced wastewater treatment processes can further reduce the impact of stormwater runoff on aquatic environment at a minimal environmental cost (77 kg CO2 eq. per kg P eq. reduction), which provides support and valuable insights for the further development of integrated management of stormwater and wastewater. The consideration of critical model parameters (i.e., precipitation intensity, land imperviousness, and infrastructure life expectancy) highlighted the importance and implications of varying local conditions and infrastructure characteristics on the costs and benefits of stormwater management. Of particular note is that the impact of MS4 on the local aquatic environment is highly dependent on local runoff quality indicating that a combined system of green infrastructure prior to MS4 potentially provides a more cost-effective improvement to local water quality.

  3. PPCPs wet weather mobilization in a combined sewer in NW Spain.

    Science.gov (United States)

    Del Río, Héctor; Suárez, Joaquín; Puertas, Jerónimo; Ures, Pablo

    2013-04-01

    An intense campaign was carried out over a 14 month period to characterize concentrations and loads of 7 well-known Pharmaceuticals and Personal Care Products (PPCPs), during dry and wet weather conditions, in an urban combined catchment in the northwest of Spain, a geographical zone with an average annual rainfall over 1500 mm. The main objective was to gather more in-depth knowledge of the mobilization of these "micropollutants" in an urban combined sewer and the possible pressures on water receiving bodies due to combined sewer overflows (CSOs). Hydrographs and pollutographs of these substances in dry weather flows (DWF), on weekdays and weekends, and wet weather flows (WWF) during 10 rain events have been characterized to obtain data that are sufficiently representative for statistical analysis. The research findings show that there is a considerable mobilization of these substances during rain events, mainly in the first part of the hydrographs, especially HHCB galaxolide, ibuprofen and paracetamol with maximum concentrations of 9.76, 8.51 and 5.71 μg/L respectively, whereas these concentrations in dry weather only reached 2.57, 2.11 and 0.72 μg/L respectively. There is a good correlation between the degree of mobilization in wet weather flows and the percentage of dry weather particulate phase of each studied substance, indicating that such mobilization may be associated with adsorption on the sediments deposited on the collectors during the antecedent dry period. These results are in good agreement with removal in conventional WWTP, especially for compounds that tend to adsorb onto sewage sludge. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Dynamic gauge adjustment of high-resolution X-band radar data for convective rain storms: Model-based evaluation against measured combined sewer overflow

    Science.gov (United States)

    Borup, Morten; Grum, Morten; Linde, Jens Jørgen; Mikkelsen, Peter Steen

    2016-08-01

    Numerous studies have shown that radar rainfall estimates need to be adjusted against rain gauge measurements in order to be useful for hydrological modelling. In the current study we investigate if adjustment can improve radar rainfall estimates to the point where they can be used for modelling overflows from urban drainage systems, and we furthermore investigate the importance of the aggregation period of the adjustment scheme. This is done by continuously adjusting X-band radar data based on the previous 5-30 min of rain data recorded by multiple rain gauges and propagating the rainfall estimates through a hydraulic urban drainage model. The model is built entirely from physical data, without any calibration, to avoid bias towards any specific type of rainfall estimate. The performance is assessed by comparing measured and modelled water levels at a weir downstream of a highly impermeable, well defined, 64 ha urban catchment, for nine overflow generating rain events. The dynamically adjusted radar data perform best when the aggregation period is as small as 10-20 min, in which case it performs much better than static adjusted radar data and data from rain gauges situated 2-3 km away.

  5. Environmental Assessment for Proposed Demolition and Consolidation, Maxwell Air Force Base, Montgomery County, Alabama

    Science.gov (United States)

    2013-09-01

    51 3.11.2.2 SANITARY SEWER ...............................................................51 3.11.2.3 ELECTRICITY...72 4.2.11.2 SANITARY SEWER ...............................................................73 4.2.11.3...loam or sandy clay soils. The majority of the installation consists of the Amite-Cahaba association which is deep, well-drained, fine sandy loam

  6. Water quality in the Sugar Creek basin, Bloomington and Normal, Illinois

    Science.gov (United States)

    Prugh, Byron J.

    1978-01-01

    Urban runoff and overflows from combined sewers affect water quantity and quality in Sugar Creek within the twin cities of Bloomington and Normal, Illinois. Water-quality data from five primary and eight secondary locations showed three basic types of responses to climatic and hydrologic stresses. Stream temperatures and concentrations of dissolved oxygen, ammonia nitrogen, total phosphorus, biochemical oxygen demand, and fecal bacteria showed seasonal variations. Specific conductivity, pH, chloride, and suspended solids concentrations varied more closely with stream discharges. Total organic carbon, total nitrogen, total phosphorus, biochemical oxygen demand, and fecal coliform and fecal streptococcal bacteria concentrations exhibited variations indicative of intial flushing action during storm runoff. Selected analyses for herbicides, insecticides, and other complex organic compounds in solution and in bed material showed that these constituents were coming from sources other than the municipal sanitary treatment plant effluent. Analyses for 10 common metals: arsenic, cadmium, chromium, copper, iron, lead, manganese, mercury, nickel, and zinc showed changes in concentrations below the municipal sanitary plant outfall. (Woodard-USGS)

  7. Some Experiences with Numerical Modelling of Overflows

    DEFF Research Database (Denmark)

    Larsen, Torben; Nielsen, L.; Jensen, B.

    2007-01-01

    across the edge of the overflow. To ensure critical flow across the edge, the upstream flow must be subcritical whereas the downstream flow is either supercritical or a free jet. Experimentally overflows are well studied. Based on laboratory experiments and Froude number scaling, numerous accurate...

  8. Assessment of spill flow emissions on the basis of measured precipitation and waste water data

    Science.gov (United States)

    Hochedlinger, Martin; Gruber, Günter; Kainz, Harald

    2005-09-01

    Combined sewer overflows (CSOs) are substantial contributors to the total emissions into surface water bodies. The emitted pollution results from dry-weather waste water loads, surface runoff pollution and from the remobilisation of sewer deposits and sewer slime during storm events. One possibility to estimate overflow loads is a calculation with load quantification models. Input data for these models are pollution concentrations, e.g. Total Chemical Oxygen Demand (COD tot), Total Suspended Solids (TSS) or Soluble Chemical Oxygen Demand (COD sol), rainfall series and flow measurements for model calibration and validation. It is important for the result of overflow loads to model with reliable input data, otherwise this inevitably leads to bad results. In this paper the correction of precipitation measurements and the sewer online-measurements are presented to satisfy the load quantification model requirements already described. The main focus is on tipping bucket gauge measurements and their corrections. The results evidence the importance of their corrections due the effects on load quantification modelling and show the difference between corrected and not corrected data of storm events with high rain intensities.

  9. Sanitary-epidemiologic service in Perm region: 95th anniversary (dedicated to Russian Sanitary-epidemiologic service

    Directory of Open Access Journals (Sweden)

    V.G. Kostarev

    2017-09-01

    Full Text Available The paper outlines the first stages of sanitary activities development in Perm region. We highlight the fact that it was Perm where I.I. Molessson, the first official sanitary inspector in Russia, worked. Here one of the first sanitary inspection of a whole region was performed and "Perm sanitary bulletin" was first published. It was in Perm, where the first sanitary office was established in 1890, and in 1898 the first bacteriological laboratory was organized. Bodies and institutions of Rospotrebnadzor in Perm region are known to be founded on September 15, 1922, when a Decree by Russian People's Commissars Council "On the Republic's sanitary bodies" was issued. A sanitary-hygienic faculty of Perm Medical Institute was set up in 1931 and it gave grounds for preparing qualified sanitary inspectors for state sanitary authorities. We described basic tasks which were tackled by sanitary inspectors during the Great Patriotic War and just after it. Rospotrebnadzor activities are proved to make for substantial improvements of sanitary-epidemiologic situation in the region. Currently more than 95 % of population are provided with drinking water which fully corresponds to the sanitary legislation requirements. We note constant improvements in catering objects quality and we also see that a quantity of food samples taken at such objects which don't correspond to hygienic standards remains stably low. A share of working places deviating from hygienic standards as per noise, vibration, and illumination, has reduced. Medical examinations are now available to 97.9 % of workers functioning under hazardous (dangerous working conditions. The lowest occupa-tional morbidity level over the last few years was registered in Perm region in 2016. The Service was among the first in the country to transfer to result-oriented budgeting and risk-oriented surveillance model. Organizational structure is constantly being developed; new legal, economic and organizational

  10. Oxidation and Precipitation of Sulfide in Sewer Networks

    DEFF Research Database (Denmark)

    Nielsen, A. H.

    risks and corrosion of concrete and metals. Most of the problems relate to the buildup of hydrogen sulfide in the atmosphere of sewer networks. In this respect, the processes of the sulfur cycle are of fundamental importance in ultimately determining the extent of such problems. This study focused...... calibrated and validated against field data. In the extension to the WATS model, sulfur transformations were described by six processes: 1. Sulfide production taking place in the biofilm and sediments covering the permanently wetted sewer walls; 2. Biological sulfide oxidation in the permanently wetted...... to the sewer atmosphere, potentially resulting in concrete corrosion. The extended WATS model represents a major improvement over previously developed models for prediction of sulfide buildup in sewer networks. Compared to such models, the major processes governing sulfide buildup in sewer networks...

  11. Single electron based binary multipliers with overflow detection ...

    African Journals Online (AJOL)

    electron based device. Multipliers with overflow detection based on serial and parallel prefix computation algorithm are elaborately discussed analytically and designed. The overflow detection circuits works in parallel with a simplified multiplier to ...

  12. Sewerage Service Areas - MDC_SewerServiceArea

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — The Water and Sewer Service Area layer was derived from the original paper based sketches which contained both water and sewer utility boundary information. This...

  13. Localization of groundwater infiltration in the combined sewers of Brussels by stable isotopes measurements (δ18O, δD) by Cavity Ring Down Spectroscopy.

    Science.gov (United States)

    De Bondt, Kevin; Claeys, Philippe

    2014-05-01

    In the last 20 years research has been conducted to quantify the infiltration of groundwater into the sewers. This groundwater, called parasitic water, increases the volume of waste-water to be treated and consequently the cost of this treatment. Moreover, in the case of combined sewer systems, the parasitic water also limits the sewer capacity and indirectly increases the risks of combined sewer overflows and floods. The infiltration of groundwater occurs trough cracks, sewer collapses and from direct connections with old springs. Different methods quantify the intrusion of parasitic water. Among these, the use of the stable isotopes of water (δ18O & δD) shows good result in catchments or cities close to Mountainous regions (example from Lyon, Zurich), where isotopic signals vary significantly because of continental and altitude effects. However many cities, such as Brussels, are located in more oceanic settings and theoretically offer less potential for the application of the stable isotopes method. In the case of Brussels, river-water from the Meuse is used to produce domestic-water. The catchment of this river extends into the Ardennes, which are affected by slightly different climatic conditions. δ18O & δD analyzes of groundwater from the main aquifer (Ledo-Paniselian-Brusselian) and domestic-water from the Callois reservoir fed by the Meuse River show sufficient isotopic differences in the south of Brussels, but only during the summer. The discrimination potential is better with δD than with δ18O. The improvement of δD measurements (precision, costs,...) brought by Cavity Ring Down Spectroscopy largely contributes to the potential of using stable isotopes method to trace water in Brussels. The first campaigns in the sewers also show a little enrichment (in heavy isotopes) of the waste-water in comparison with the reservoir waters and tap waters. This increases the potential of the method but constrains the sampling to pure waste-water in sewer segments

  14. Comparison of Suspended Solid Separation in Advanced Storm Overflow Structures

    DEFF Research Database (Denmark)

    Larsen, Torben; Sørensen, Morten Steen

    1990-01-01

    This paper describes a laboratory investigation of the separation of suspended solids in a circular weir overflow and a vortex separator. The basic idea is to evaluate the efficiency of a vortical flow in the overflow chamber, and to compare these results with other overflow structures....

  15. The Sewer Research Station in Frejlev

    DEFF Research Database (Denmark)

    Schaarup-Jensen, Kjeld; Hvitved-Jacobsen, T.

    This report for the 2000 activities at the sewer research station in Frejlev. Only few - if any - sewer monitoring stations like the one in Frejlev exist. Without no doubt the field data produced - especially the time series - in the course of time will serve as a unique basis for projects dealin...

  16. The Sewer Research Station in Frejlev

    DEFF Research Database (Denmark)

    Hvitved-Jacobsen, Thorkild; Schaarup-Jensen, Kjeld

    This report for the 1999 activities at the sewer research station in Frejlev. Only few - if any - sewer monitoring stations like the one in Frejlev exist. Without no doubt the field data produced - especially the time series - in the course of time will serve as a unigue basis for projects dealin...

  17. Tolerable Time-Varying Overflow on Grass-Covered Slopes

    Directory of Open Access Journals (Sweden)

    Steven A. Hughes

    2015-03-01

    Full Text Available Engineers require estimates of tolerable overtopping limits for grass-covered levees, dikes, and embankments that might experience steady overflow. Realistic tolerance estimates can be used for both resilient design and risk assessment. A simple framework is developed for estimating tolerable overtopping on grass-covered slopes caused by slowly-varying (in time overtopping discharge (e.g., events like storm surges or river flood waves. The framework adapts the well-known Hewlett curves of tolerable limiting velocity as a function of overflow duration. It has been hypothesized that the form of the Hewlett curves suggests that the grass erosion process is governed by the flow work on the slope above a critical threshold velocity (referred to as excess work, and the tolerable erosional limit is reached when the cumulative excess work exceeds a given value determined from the time-dependent Hewlett curves. The cumulative excess work is expressed in terms of overflow discharge above a critical discharge that slowly varies in time, similar to a discharge hydrograph. The methodology is easily applied using forecast storm surge hydrographs at specific locations where wave action is minimal. For preliminary planning purposes, when storm surge hydrographs are unavailable, hypothetical equations for the water level and overflow discharge hydrographs are proposed in terms of the values at maximum overflow and the total duration of overflow. An example application is given to illustrate use of the methodology.

  18. Online monitoring and conditional regression tree test: Useful tools for a better understanding of combined sewer network behavior.

    Science.gov (United States)

    Bersinger, T; Bareille, G; Pigot, T; Bru, N; Le Hécho, I

    2018-06-01

    A good knowledge of the dynamic of pollutant concentration and flux in a combined sewer network is necessary when considering solutions to limit the pollutants discharged by combined sewer overflow (CSO) into receiving water during wet weather. Identification of the parameters that influence pollutant concentration and flux is important. Nevertheless, few studies have obtained satisfactory results for the identification of these parameters using statistical tools. Thus, this work uses a large database of rain events (116 over one year) obtained via continuous measurement of rainfall, discharge flow and chemical oxygen demand (COD) estimated using online turbidity for the identification of these parameters. We carried out a statistical study of the parameters influencing the maximum COD concentration, the discharge flow and the discharge COD flux. In this study a new test was used that has never been used in this field: the conditional regression tree test. We have demonstrated that the antecedent dry weather period, the rain event average intensity and the flow before the event are the three main factors influencing the maximum COD concentration during a rainfall event. Regarding the discharge flow, it is mainly influenced by the overall rainfall height but not by the maximum rainfall intensity. Finally, COD discharge flux is influenced by the discharge volume and the maximum COD concentration. Regression trees seem much more appropriate than common tests like PCA and PLS for this type of study as they take into account the thresholds and cumulative effects of various parameters as a function of the target variable. These results could help to improve sewer and CSO management in order to decrease the discharge of pollutants into receiving waters. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Self-optimising control of sewer systems

    DEFF Research Database (Denmark)

    Mauricio Iglesias, Miguel; Montero-Castro, Ignacio; Mollerup, Ane Loft

    2013-01-01

    . The definition of an optimal performance was carried out by through a two-stage optimisation (stochastic and deterministic) to take into account both the overflow during the current rain event as well as the expected overflow, given the probability of a future rain event. The methodology is successfully applied...

  20. The hydraulic capacity of deteriorating sewer systems.

    Science.gov (United States)

    Pollert, J; Ugarelli, R; Saegrov, S; Schilling, W; Di Federico, V

    2005-01-01

    Sewer and wastewater systems suffer from insufficient capacity, construction flaws and pipe deterioration. Consequences are structural failures, local floods, surface erosion and pollution of receiving waters bodies. European cities spend in the order of five billion Euro per year for wastewater network rehabilitation. This amount is estimated to increase due to network ageing. The project CARE-S (Computer Aided RE-habilitation of Sewer Networks) deals with sewer and storm water networks. The final project goal is to develop integrated software, which provides the most cost-efficient system of maintenance, repair and rehabilitation of sewer networks. Decisions on investments in rehabilitation often have to be made with uncertain information about the structural condition and the hydraulic performance of a sewer system. Because of this, decision-making involves considerable risks. This paper presents the results of research focused on the study of hydraulic effects caused by failures due to temporal decline of sewer systems. Hydraulic simulations are usually carried out by running commercial models that apply, as input, default values of parameters that strongly influence results. Using CCTV inspections information as dataset to catalogue principal types of failures affecting pipes, a 3D model was used to evaluate their hydraulic consequences. The translation of failures effects in parameters values producing the same hydraulic conditions caused by failures was carried out through the comparison of laboratory experiences and 3D simulations results. Those parameters could be the input of 1D commercial models instead of the default values commonly inserted.

  1. An Environmental Innovation: The Sewer Mouse

    Science.gov (United States)

    1979-01-01

    In the effort to clean up America's waters, there is a little-known complicating factor: because they leak, sewer systems in many American cities are causing rather than preventing pollution of rivers and lakes. Fixing the leaks is difficult because their locations are unknown. Maintenance crews can't tear up a whole city looking for cracks in the pipes; they must first determine which areas are most likely suspects. An aerospace spinoff is providing help in that regard. The problem starts with heavy rains. Rainwater naturally flows into the sewers from streets, but sewage systems are designed to accommodate it. However, they are not designed to handle the additional flow of "groundwater", rain absorbed by the earth which seeps into the sewers through leaks in pipes and sewer walls. After a storm, groundwater seepage can increase the waterflow to deluge proportions, with the result that sewage treatment plants are incapable of processing the swollen flow. When that happens the sluices must be opened, dumping raw sewage into rivers and lakes.

  2. Information use in Dutch sewer assest management

    NARCIS (Netherlands)

    Van Riel, W.A.P.; Langeveld, J.G.; Herder, P.M.; Clemens, F.H.L.R.

    2012-01-01

    Sewer systems are capital-intensive infrastructures, requiring appropriate asset management to safeguard serviceability. In the Netherlands, effective sewer asset management is described by De Leeuw’s control paradigm. Reliable data and information are key elements in decision-making for

  3. Development of Overflow-Prevention Valve with Trigger Mechanism.

    Science.gov (United States)

    Ishino, Yuji; Mizuno, Takeshi; Takasaki, Masaya

    2016-09-01

    A new overflow-prevention valve for combustible fluid is developed which uses a trigger mechanism. Loading arms for combustible fluid are used for transferring oil from a tanker to tanks and vice versa. The loading arm has a valve for preventing overflow. Overflow- prevention valves cannot use any electric component to avoid combustion. Therefore, the valve must be constructed only by mechanical parts. The conventional overflow-prevention valve uses fluid and pneumatic forces. It consists of a sensor probe, a cylinder, a main valve for shutting off the fluid and a locking mechanism for holding an open state of the main valve. The proposed overflow-prevention valve uses the pressure due to the height difference between the fluid level of the tank and the sensor probe. However, the force of the cylinder produced by the pressure is too small to release the locking mechanism. Therefore, a trigger mechanism is introduced between the cylinder and the locking mechanism. The trigger mechanism produces sufficient force to release the locking mechanism and close the main valve when the height of fluid exceeds a threshold value. A trigger mechanism is designed and fabricated. The operation necessary for closing the main valve is conformed experimentally.

  4. Long forecast horizon to improve Real Time Control of urban drainage systems

    DEFF Research Database (Denmark)

    Courdent, Vianney Augustin Thomas; Vezzaro, Luca; Mikkelsen, Peter Steen

    2014-01-01

    Global Real Time Control (RTC) of urban drainage system is increasingly seen as cost-effective solution in order to respond to increasing performance demand (e.g. reduction of Combined Sewer Overflow, protection of sensitive areas as bathing water etc.). The Dynamic Overflow Risk Assessment (DORA......) strategy was developed to operate Urban Drainage Systems (UDS) in order to minimize the expected overflow risk by considering the water volume presently stored in the drainage network, the expected runoff volume based on a 2-hours radar forecast model and an estimated uncertainty of the runoff forecast....... However, such temporal horizon (1-2 hours) is relatively short when used for the operation of large storage facilities, which may require a few days to be emptied. This limits the performance of the optimization and control in reducing combined sewer overflow and in preparing for possible flooding. Based...

  5. Using ensemble weather forecast in a risk based real time optimization of urban drainage systems

    DEFF Research Database (Denmark)

    Courdent, Vianney Augustin Thomas; Vezzaro, Luca; Mikkelsen, Peter Steen

    2015-01-01

    Global Real Time Control (RTC) of urban drainage system is increasingly seen as cost-effective solution in order to respond to increasing performance demand (e.g. reduction of Combined Sewer Overflow, protection of sensitive areas as bathing water etc.). The Dynamic Overflow Risk Assessment (DORA......) strategy was developed to operate Urban Drainage Systems (UDS) in order to minimize the expected overflow risk by considering the water volume presently stored in the drainage network, the expected runoff volume based on a 2-hours radar forecast model and an estimated uncertainty of the runoff forecast....... However, such temporal horizon (1-2 hours) is relatively short when used for the operation of large storage facilities, which may require a few days to be emptied. This limits the performance of the optimization and control in reducing combined sewer overflow and in preparing for possible flooding. Based...

  6. Damage estimation of sewer pipe using subtitles of CCTV inspection video

    Science.gov (United States)

    Park, Kitae; Kim, Byeongcheol; Kim, Taeheon; Seo, Dongwoo

    2017-04-01

    Recent frequent occurrence of urban sinkhole serves as a momentum of the periodic inspection of sewer pipelines. Sewer inspection using a CCTV device needs a lot of time and efforts. Many of previous studies which reduce the laborious tasks are mainly interested in the developments of image processing S/W and exploring H/W. And there has been no attempt to find meaningful information from the existing CCTV images stored by the sewer maintenance manager. This study adopts a cross-correlation based image processing method and extracts sewer inspection device's location data from CCTV images. As a result of the analysis of location-time relation, it show strong correlation between device stand time and the sewer damages. In case of using this method to investigate sewer inspection CCTV images, it will save the investigator's efforts and improve sewer maintenance efficiency and reliability.

  7. SSOs, CMOM, and the regulator's role

    International Nuclear Information System (INIS)

    McClary, S.C.

    2002-01-01

    This paper describes the program that the Oklahoma Department of Environmental Quality (DEQ) currently has in place to manage sanitary sewer overflows. The program includes permitting, compliance, enforcement and education elements. In addition, the provisions of the CMOM (capacity, management, operation, and maintenance program) rule that are new to Oklahoma are discussed. Finally, reactions to the proposed rules by other regulatory agencies and Oklahoma's conclusions are included. The DEQ has taken an active role in the development of the EPA collection system/CMOM rule. This role was a natural progression of the program that the DEQ and predecessor state agencies have implemented since the 1980's. Although there has been an increase in workload due to collection system overflow issues being made a priority, there has also been a benefit to the environment in Oklahoma. The existing program at the DEQ contains many of the required elements included in the draft CMOM regulations including: 1) 24-hour reporting of any overflow; 2) a regulatory database maintained that includes information relating to an overflow; and 3) operation and maintenance requirements for the treatment system, including the collection system. In addition, the DEQ has an established enforcement program that has implemented non-compliance criteria and a matrix to determine enforcement action. Additionally, the DEQ has developed and implemented an education program to assist in compliance attainment. This paper includes the following: DEQ's existing permitting, compliance, enforcement, and education program; CMOM program elements new to DEQ; Reaction of other entities to the proposed CMOM rule; and Oklahoma's conclusions. (author)

  8. Systems with selective overflow and change of bandwidth

    DEFF Research Database (Denmark)

    Iversen, Villy Bæk

    2012-01-01

    on the overflow group, we show by balance equations that the number of calls of each service will be Multinomial distributed with probabilities proportional with the arrival rates. Using a recent result of Newcomer & al, we then find moments (done up to fourth order) of individual overflow streams or any...

  9. URBAN RUNOFF POLLUTION CONTROL - STATE-OF-THE-ART

    Science.gov (United States)

    Combined sewer overflows are major sources of water pollution problems, but even discharges of stormwater alone can seriously affect water quality. Current approaches involve control of overflows, treatment, and combinations of the two. Control may involve maximizing treatment wi...

  10. Installation Restoration Program. Phase 1. Records Search, Scott AFB, Illinois

    Science.gov (United States)

    1985-04-01

    mission of defense of the United States, has long been engaged in a wide variety of opera- tions dealing with toxic and hazardous materials. Federal...Histopathology-Cytology Sewer Dental Clinic/Laboratory 1680 Yes Yes DPDO, Sanitary Sewer, Medical Logistics Radiology/X-Ray 1680 Yes Yes DPDO, Sanitary...disintegrate. HALOGEN: The class of chemical elements including fluorine , chlorine, i bromine, and iodine. HALON 1211: A fire extinguishing agent

  11. Model Predictive Control of Sewer Networks

    DEFF Research Database (Denmark)

    Pedersen, Einar B.; Herbertsson, Hannes R.; Niemann, Henrik

    2016-01-01

    The developments in solutions for management of urban drainage are of vital importance, as the amount of sewer water from urban areas continues to increase due to the increase of the world’s population and the change in the climate conditions. How a sewer network is structured, monitored and cont...... benchmark model. Due to the inherent constraints the applied approach is based on Model Predictive Control....

  12. Evaluation of Confining Layer Integrity Beneath the South District Wastewater Treatment Plant, Miami-Dade Water and Sewer Department, Dade County, Florida

    Energy Technology Data Exchange (ETDEWEB)

    Starr, Robert Charles; Green, Timothy Scott; Hull, Laurence Charles

    2001-02-01

    A review has been performed of existing information that describes geology, hydrogeology, and geochemistry at the South District Wastewater Treatment Plant, which is operated by the Miami-Dade Water and Sewer Department, in Dade County, Florida. Treated sanitary wastewater is injected into a saline aquifer beneath the plant. Detection of contaminants commonly associated with treated sanitary wastewater in the freshwater aquifer that overlies the saline aquifer has indicated a need for a reevaluation of the ability of the confining layer above the saline aquifer to prevent fluid migration into the overlying freshwater aquifer. Review of the available data shows that the geologic data set is not sufficient to demonstrate that a competent confining layer is present between the saline and freshwater aquifers. The hydrogeologic data also do not indicate that a competent confining layer is present. The geochemical data show that the freshwater aquifer is contaminated with treated wastewater, and the spatial patterns of contamination are consistent with upward migration through localized conduits through the Middle Confining Unit, such as leaking wells or natural features. Recommendations for collection and interpretation of additional site characterization data are provided.

  13. The fate of radioactivity in sewers

    International Nuclear Information System (INIS)

    2000-01-01

    The Environment Agencies authorise and monitor the disposal of low-level radioactive waste to sewers. Such discharges originate from non-nuclear sites such as hospitals, universities and research centres. Discharges are strictly controlled through authorisations, which place conditions and limits on the disposer. We commissioned the work summarised within this, leaflet to reassess the fate of these radioactive discharges and to ensure that this practice remains acceptable and is still the best option for disposal. In all cases the study found assessed radiation doses (associated with these discharges) to be a small fraction of the public dose limit. The Environment Agencies conclude from this study that the disposal of radioactive waste to sewers remains the best option available to ensure the safety of the public (including sewer workers) and to protect the environment

  14. Remaining Sites Verification Package for the 1607-F1 Sanitary Sewer System (124-F-1) and the 100-F-26:8 (1607-F1) Sanitary Sewer Pipelines Waste Sites. Attachment to Waste Site Reclassification Forms 2004-130 and 2005-004

    International Nuclear Information System (INIS)

    Dittmer, L.M.

    2008-01-01

    The 100-F-26:8 waste site consisted of the underground pipelines that conveyed sanitary waste water from the 1701-F Gatehouse, 1709-F Fire Station, and the 1720-F Administrative Office to the 1607-F1 septic tank. The site has been remediated and presently exists as an open excavation. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling demonstrated that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also showed that residual contaminant concentrations are protective of groundwater and the Columbia River

  15. Factors affecting economies of scale in combined sewer systems.

    Science.gov (United States)

    Maurer, Max; Wolfram, Martin; Anja, Herlyn

    2010-01-01

    A generic model is introduced that represents the combined sewer infrastructure of a settlement quantitatively. A catchment area module first calculates the length and size distribution of the required sewer pipes on the basis of rain patterns, housing densities and area size. These results are fed into the sewer-cost module in order to estimate the combined sewer costs of the entire catchment area. A detailed analysis of the relevant input parameters for Swiss settlements is used to identify the influence of size on costs. The simulation results confirm that an economy of scale exists for combined sewer systems. This is the result of two main opposing cost factors: (i) increased construction costs for larger sewer systems due to larger pipes and increased rain runoff in larger settlements, and (ii) lower costs due to higher population and building densities in larger towns. In Switzerland, the more or less organically grown settlement structures and limited land availability emphasise the second factor to show an apparent economy of scale. This modelling approach proved to be a powerful tool for understanding the underlying factors affecting the cost structure for water infrastructures.

  16. Modelling the viability of heat recovery from combined sewers.

    Science.gov (United States)

    Abdel-Aal, M; Smits, R; Mohamed, M; De Gussem, K; Schellart, A; Tait, S

    2014-01-01

    Modelling of wastewater temperatures along a sewer pipe using energy balance equations and assuming steady-state conditions was achieved. Modelling error was calculated, by comparing the predicted temperature drop to measured ones in three combined sewers, and was found to have an overall root mean squared error of 0.37 K. Downstream measured wastewater temperature was plotted against modelled values; their line gradients were found to be within the range of 0.9995-1.0012. The ultimate aim of the modelling is to assess the viability of recovering heat from sewer pipes. This is done by evaluating an appropriate location for a heat exchanger within a sewer network that can recover heat without impacting negatively on the downstream wastewater treatment plant (WWTP). Long sewers may prove to be more viable for heat recovery, as heat lost can be reclaimed before wastewater reaching the WWTP.

  17. Analysis and integrated modelling of groundwater infiltration to sewer networks

    DEFF Research Database (Denmark)

    Thorndahl, Søren Liedtke; Balling, Jonas Dueholm; Larsen, Uffe Bay Bøgh

    2016-01-01

    Infiltration of groundwater to sewer systems is a problem for the capacity of the system as well as for treatment processes at waste water treatment plants. This paper quantifies the infiltration of groundwater to a sewer system in Frederikshavn Municipality, Denmark, by measurements of sewer flo...

  18. Contributions of wastewater, runoff and sewer deposit erosion to wet weather pollutant loads in combined sewer systems.

    Science.gov (United States)

    Gasperi, J; Gromaire, M C; Kafi, M; Moilleron, R; Chebbo, G

    2010-12-01

    An observatory of urban pollutants was created in Paris for the purpose of assessing the dynamics of wastewater and wet weather flow (WW and WWF) pollutant loads within combined sewers. This observatory is composed of six urban catchments, covering land areas ranging in size from 42 ha to 2581 ha. For a wide array of parameters including total suspended solids (TSS), chemical and biochemical oxygen demand (COD and BOD(5)), total organic carbon (TOC), total Kjeldahl nitrogen (TKN), heavy metals (Cu and Zn) and polycyclic aromatic hydrocarbons (PAHs), this article is intended to evaluate the contributions of wastewater, runoff and in-sewer processes to WWF pollutant loads through the use of an entry-exit mass balance approach. To achieve this objective, a total of 16 rain events were sampled on these sites between May 2003 and February 2006. This study has confirmed that at the considered catchment scale (i.e. from 42 ha to 2581 ha) the production and transfer processes associated with WWF pollutant loads do not vary with basin scale. Entry-exit chemical mass balances over all catchments and for a large number of rain events indicate that wastewater constitutes the main source of organic and nitrogenous pollution, while runoff is the predominant source of Zn. For Cu, PAHs and TSS, the calculation underscores the major role played by in-sewer processes, specifically by sediment erosion, as a source of WWF pollution. A significant loss of dissolved metals was also observed during their transfer within the sewer network, likely as a consequence of the adsorption of dissolved metals on TSS and/or on sewer deposits. Moreover, the nature of eroded particles was examined and compared to the various sewer deposits. This comparison has highlighted that such particles exhibit similar organic and PAH contents to those measured in the organic layer, thus suggesting that the deposit eroded during a wet weather period is organic and of a nature comparable to the organic layer

  19. Sanitary effects of fossil fuels

    International Nuclear Information System (INIS)

    Nifenecker, H.

    2006-01-01

    In this compilation are studied the sanitary effects of fossil fuels, behavioral and environmental sanitary risks. The risks in connection with the production, the transport and the distribution(casting) are also approached for the oil(petroleum), the gas and the coal. Accidents in the home are evoked. The risks due to the atmospheric pollution are seen through the components of the atmospheric pollution as well as the sanitary effects of this pollution. (N.C.)

  20. Assessing the performance of sewer rehabilitation on the reduction of infiltration and inflow.

    Science.gov (United States)

    Staufer, P; Scheidegger, A; Rieckermann, J

    2012-10-15

    Inflow and Infiltration (I/I) into sewer systems is generally unwanted, because, among other things, it decreases the performance of wastewater treatment plants and increases combined sewage overflows. As sewer rehabilitation to reduce I/I is very expensive, water managers not only need methods to accurately measure I/I, but also they need sound approaches to assess the actual performance of implemented rehabilitation measures. However, such performance assessment is rarely performed. On the one hand, it is challenging to adequately take into account the variability of influential factors, such as hydro-meteorological conditions. On the other hand, it is currently not clear how experimental data can indeed support robust evidence for reduced I/I. In this paper, we therefore statistically assess the performance of rehabilitation measures to reduce I/I. This is possible by using observations in a suitable reference catchment as a control group and assessing the significance of the observed effect by regression analysis, which is well established in other disciplines. We successfully demonstrate the usefulness of the approach in a case study, where rehabilitation reduced groundwater infiltration by 23.9%. A reduction of stormwater inflow of 35.7%, however, was not statistically significant. Investigations into the experimental design of monitoring campaigns confirmed that the variability of the data as well as the number of observations collected before the rehabilitation impact the detection limit of the effect. This implies that it is difficult to improve the data quality after the rehabilitation has been implemented. Therefore, future practical applications should consider a careful experimental design. Further developments could employ more sophisticated monitoring methods, such as stable environmental isotopes, to directly observe the individual infiltration components. In addition, water managers should develop strategies to effectively communicate statistically

  1. Radiation exposure of sewer workers associated with radioactive discharges from hospitals

    International Nuclear Information System (INIS)

    McDonnell, C.E.; Wilkins, S.

    1991-07-01

    Models have been developed to estimate the dispersion of radionuclides discharged into the sewer system serving a hospital where nuclear medicine and other techniques are used, and to assess the radiation doses to sewer workers and maintenance staff who may be exposed to these discharges. The dispersion model has been tested in a practical situation for the radionuclide 131 I. For a typical combination of hospital and sewer works, the estimated critical group doses arising from discharges of four selected radionuclides, 32 P, 99m Tc, 125 I and 131 I, are 30 μSv y -1 and 20 μSv y -1 respectively for a worker at the sewer works and for a sewer maintenance worker exposed for prolonged periods in the region of the sewer system adjacent to the hospital discharge point. (author)

  2. Development of Sediment Deposition Height Capacity Equation in Sewer Networks

    Science.gov (United States)

    Song, Yangho; Jo, Deokjun; Lee, Jungho

    2017-04-01

    Sediment characteristics and transport processes in sewers are markedly different from river. There is a wide range of particle densities and smaller particle size variation in sewers. Sediment supply and the available erodible material are more limited in sewers, and the diverse hydraulic characteristics in sewer systems are more unsteady. Prevention of sewer sediment accumulation, which can cause major sewer operational problems, is imperative and has been an immense concern for engineers. The effects of sediment formation in sewer systems, an appropriate sediment transport modelling with the ability to determine the location and depth of sediment deposit is needed. It is necessary to design efficiently considering the transfer and settling phenomena of the sediment coming into the sewer systems. During transport in the sewer, the minimum shear flow velocity and possible shear stress at which the sediment is transported smoothly. However, the interaction of sediment and fluid within the sewer systems has been very complex and the rigorous theoretical handling of this problem has not been developed. It is derived from the empirical values obtained from the river bed. The basic theory that particles float is based on the balance between sedimentation of particles by gravity and turbulent diffusion of fluids. There are many variables related. Representative parameters include complex phenomena due to collisions between particles, particles and fluids, and interactions between particles and tube walls. In general, the main parameters that form the boundary between the main transport and sediment are particle size, density, volume fraction, pipe diameter and gravity. As the particle size and volume concentration increase, the minimum feed rate increases and the same tendency is observed for the change of the capillary diameter. Based on this tendency, this study has developed a sediment deposition height capacity formula to take into consideration the sewer discharge

  3. 40 CFR 35.935-16 - Sewer use ordinance and evaluation/rehabilitation program.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Sewer use ordinance and evaluation...-Clean Water Act § 35.935-16 Sewer use ordinance and evaluation/rehabilitation program. (a) The grantee... sewer use ordinance, and the grantee is complying with the sewer system evaluation and rehabilitation...

  4. Overflow control valve

    International Nuclear Information System (INIS)

    Kessinger, B.A.; Hundal, R.; Parlak, E.A.

    1982-01-01

    An overflow control valve for use in a liquid sodium coolant pump tank which can be remotely engaged with and disengaged from the pump tank wall to thereby permit valve removal. An actuating shaft for controlling the valve also has means for operating a sliding cylinder against a spring to retract the cylinder from sealing contact with the pump tank nozzle. (author)

  5. Methodology for Identifying and Quantifying Metal Pollutant Sources in Storm Water Runoff

    Science.gov (United States)

    2015-02-01

    sanitary sewer are not viable options. In addition, visual inspections of the drainage areas have been insufficient in identifying and quantifying the...diverting the runoff into the sanitary sewer system, but the cost could exceed millions of dollars. Instead of capturing and treating all stormwater...Unknown Appears only if Building Siding is “metal” Roof Material roof_mat_d Built Up, Metal Panel, Asphalt, Fabric, Clay , Slate, Wood, Other

  6. Storm water management implications on WWTPS in combined sewer systems: Integration strategies and process conditions; Implicaciones sobre la estacion depuradora de la gestion de aguas pluviales en los sistemas de saneamiento unitario: estrategias de integracion y afecciones sobre los procesos

    Energy Technology Data Exchange (ETDEWEB)

    Suarez Lopez, J.; Jacome Burgos, A.; Anta Alvarez, J.; Blanco Menendez, J. P.; Hernaez Oubina, D.; Rio Cambeses, H. del

    2012-07-01

    New design and strategies to manage wet weather floes in combined sewer systems, which main objective is to minimize environmental impacts on water bodies, require the treatment of large volumes of storm water. Wet weather flows introduced into combined sewer show dynamic-transient behavior both in terms of flow discharges and pollution. With traditional design strategies, large pollution peaks are spilled during rain events into water receiving bodies by combined sewer overflows (CSOs). Nowadays, CSOs have been reduced providing some storage capacity into the combined sewer systems (either in network, by means storm water tanks, or in WWTP). The stored storm water and its associated pollution should be treated. WWTP inflows during rainy events are conditioned by the local storm water management strategy. The WWTP can be overcome if it is managed using traditional dry weather strategies. In order to optimize the treatment performance and to assure that urban pollution do not reach aquatic environment, the WWTP must participate in the system in an integrated manner. This is a key element. This paper shows firstly the importance of CSO pollution and the development of new strategies for storm water management in combined sewer systems. Storm water tanks, located in the sewerage system, have been one of the most common solutions adopted but there are some experiences of wet weather flow management at the WWTP. All these strategies are revised in the paper. Once the role of the WWTP in the new combined sewer systems is known, the article presents a review about the problems generated by the hydraulic overloads and the large variations of the pollution characteristics on different stages of the water line. Special emphasis is made on the problems generated in secondary processes based on activated sludge. these problems are analysed in detail and some mitigation strategies are proposed. (Author) 20 refs.

  7. Eliminating gas overflows at the Alansk deposit. [USSR

    Energy Technology Data Exchange (ETDEWEB)

    Tulyagonov, Kh.T.; Chernopyatov, V.G.; Normatov, A.N.; Rakhimov, A.K.; Strelko, I.Sh.; Telegin, V.V.

    1981-01-01

    Causes for the appearance of gas overflows from the 15th producing horizon of the Jurassic deposits from AVPD (2834 m) to the 9th horizon of Senoman deposits (1275-1297 m range) occurring as a result of the breakdown at the 219-mm intermediate column at a depth of 1350 m, along with operations performed to eliminate these overflows, are described.

  8. Reducing CSOs and giving the river back to the public: innovative combined sewer overflow control and riverbanks restoration of the St. Charles River in Quebec City.

    Science.gov (United States)

    Fradet, Olivier; Pleau, Martin; Marcoux, Christiane

    2011-01-01

    After the construction of its wastewater treatment plants, the City of Quebec began to implement overflow control in wet weather to ultimately meet the effluent discharge objectives, i.e. no more than two overflows per summer season in the St. Lawrence River and no more than four in the St-Charles River. After several years of studies to determine which management strategies would best suit the purpose, and to propose optimum solutions, a first project to implement optimal and predictive management in real time, called "Pilot", came to life in 1999. Construction in phases soon followed and the work was completed in the fall of 2009. As a result, requirements with regard to environmental rejects were met in two sectors, namely the St-Charles River and the Jacques-Cartier Beach, and aquatic recreational activities could resume. Meanwhile, the City also worked at giving back access to the water courses to the public by developing sites at the Jacques-Cartier Beach and in the Bay of Beauport, and by rehabilitating the banks of the St-Charles River.

  9. 40 CFR 35.925-21 - Storm sewers.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Storm sewers. 35.925-21 Section 35.925... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.925-21 Storm... treatment works for control of pollutant discharges from a separate storm sewer system (as defined in § 35...

  10. Regulatory control analysis and design for sewer systems

    DEFF Research Database (Denmark)

    Mollerup, Ane Loft; Mikkelsen, Peter Steen; Thornberg, Dines

    2015-01-01

    A systematic methodology for regulatory control analysis and design is adapted for sewer system operation and evaluated. The main challenge with adapting the methodology is the handling of the stochastic and transient nature of the rainfall disturbances, inherent to sewer system operation...

  11. Organization of setting-up sanitary pass-control regime and sanitary treatment of injured persons in case of radiation accidents

    International Nuclear Information System (INIS)

    Korostin, A.S.; Klochkov, V.N.; Yatsenko, V.N.

    1995-01-01

    The main aim of sanitary pass-control regime is to prevent propagation of radioactive contamination outside the area of emergency-rescue works and guarantee of sanitary treatment of all persons having radioactive contamination. The paper has studied the questions of organization of sanitary pass-control regime, arrangement of sanitary treatment of the injured persons and rendering first aid in case of radioactive contamination of wounds. 5 refs

  12. Prioritizing sewer rehabilitation projects using AHP-PROMETHEE II ranking method.

    Science.gov (United States)

    Kessili, Abdelhak; Benmamar, Saadia

    2016-01-01

    The aim of this paper is to develop a methodology for the prioritization of sewer rehabilitation projects for Algiers (Algeria) sewer networks to support the National Sanitation Office in its challenge to make decisions on prioritization of sewer rehabilitation projects. The methodology applies multiple-criteria decision making. The study includes 47 projects (collectors) and 12 criteria to evaluate them. These criteria represent the different issues considered in the prioritization of the projects, which are structural, hydraulic, environmental, financial, social and technical. The analytic hierarchy process (AHP) is used to determine weights of the criteria and the Preference Ranking Organization Method for Enrichment Evaluations (PROMETHEE II) method is used to obtain the final ranking of the projects. The model was verified using the sewer data of Algiers. The results have shown that the method can be used for prioritizing sewer rehabilitation projects.

  13. Assessment of the contribution of sewer deposits to suspended solids loads in combined sewer systems during rain events.

    Science.gov (United States)

    Hannouche, A; Chebbo, G; Joannis, C

    2014-04-01

    Within the French observatories network SOERE "URBIS," databases of continuous turbidity measurements accumulating hundreds of events and many dry weather days are available for two sites with different features (Clichy in Paris and Ecully in Lyon). These measurements, converted into total suspended solids (TSS) concentration using TSS-turbidity relationships and combined with a model of runoff event mean concentration, enable the assessment of the contribution of sewer deposits to wet weather TSS loads observed at the outlet of the two watersheds. Results show that the contribution of sewer deposits to wet weather suspended solid's discharges is important but variable (between 20 and 80 % of the mass at the outlet depending on the event), including a site allegedly free of (coarse) sewer deposits. The uncertainties associated to these results are assessed too.

  14. A dynamic ventilation model for gravity sewer networks.

    Science.gov (United States)

    Wang, Y C; Nobi, N; Nguyen, T; Vorreiter, L

    2012-01-01

    To implement any effective odour and corrosion control technology in the sewer network, it is imperative that the airflow through gravity sewer airspaces be quantified. This paper presents a full dynamic airflow model for gravity sewer systems. The model, which is developed using the finite element method, is a compressible air transport model. The model has been applied to the North Head Sewerage Ocean Outfall System (NSOOS) and calibrated using the air pressure and airflow data collected during October 2008. Although the calibration is focused on forced ventilation, the model can be applied to natural ventilation as well.

  15. On-line monitoring of methane in sewer air.

    Science.gov (United States)

    Liu, Yiwen; Sharma, Keshab R; Murthy, Sudhir; Johnson, Ian; Evans, Ted; Yuan, Zhiguo

    2014-10-16

    Methane is a highly potent greenhouse gas and contributes significantly to climate change. Recent studies have shown significant methane production in sewers. The studies conducted so far have relied on manual sampling followed by off-line laboratory-based chromatography analysis. These methods are labor-intensive when measuring methane emissions from a large number of sewers, and do not capture the dynamic variations in methane production. In this study, we investigated the suitability of infrared spectroscopy-based on-line methane sensors for measuring methane in humid and condensing sewer air. Two such sensors were comprehensively tested in the laboratory. Both sensors displayed high linearity (R(2) > 0.999), with a detection limit of 0.023% and 0.110% by volume, respectively. Both sensors were robust against ambient temperature variations in the range of 5 to 35°C. While one sensor was robust against humidity variations, the other was found to be significantly affected by humidity. However, the problem was solved by equipping the sensor with a heating unit to increase the sensor surface temperature to 35°C. Field studies at three sites confirmed the performance and accuracy of the sensors when applied to actual sewer conditions, and revealed substantial and highly dynamic methane concentrations in sewer air.

  16. Loads of Sewer Manholes within Mining Area

    Directory of Open Access Journals (Sweden)

    Magdalena Zięba

    2014-01-01

    Originality/Value: The presented method is an original concept. It enables the determination of additional external horizontal loads acting on sewer manholes within mining areas, in particular the flexible manholes made of thermoplastics. It also enables the determination of dependencies of changes in the cross-sections of risers of flexible sewer manholes (with different circumferential stiffness on the horizontal soil strains.

  17. Perceptual consciousness overflows cognitive access.

    Science.gov (United States)

    Block, Ned

    2011-12-01

    One of the most important issues concerning the foundations of conscious perception centers on the question of whether perceptual consciousness is rich or sparse. The overflow argument uses a form of 'iconic memory' to argue that perceptual consciousness is richer (i.e., has a higher capacity) than cognitive access: when observing a complex scene we are conscious of more than we can report or think about. Recently, the overflow argument has been challenged both empirically and conceptually. This paper reviews the controversy, arguing that proponents of sparse perception are committed to the postulation of (i) a peculiar kind of generic conscious representation that has no independent rationale and (ii) an unmotivated form of unconscious representation that in some cases conflicts with what we know about unconscious representation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Environmental Assessment Distributed Common Ground System (DCGS) Operations Facility, Beale Air Force Base, California

    Science.gov (United States)

    2014-07-01

    corner of 10th and B Streets. The new building would be connected to existing electrical, communication, natural gas, water, and sanitary sewer...would be connected to existing electrical, communication, natural gas, water, and sanitary sewer systems and lines on the project site. The areas of... clay loam starting at approximately 6 inches, to clay at 19 inches, to a duripan from 20 to 40 inches. The Redding soils are moderately deep to

  19. Numerical Modelling Approaches for Sediment Transport in Sewer Systems

    DEFF Research Database (Denmark)

    Mark, Ole

    A study of the sediment transport processes in sewers has been carried out. Based on this study a mathematical modelling system has been developed to describe the transport processes of sediments and dissolved matter in sewer systems. The modelling system consists of three sub-models which...... constitute the basic modelling system necessary to give a discription of the most dominant physical transport processes concerning particles and dissolved matter in sewer systems: A surface model. An advection-dispersion model. A sediment transport model....

  20. Chemical disinfection of combined sewer overflows

    DEFF Research Database (Denmark)

    Chhetri, Ravi Kumar

    of the residual disinfectants PFA, PAA and chlorine dioxide (ClO2), and their degradation products hydrogen peroxide and chlorite, in relation to organisms in the aquatic ecosystem was studied. With the help of ecotoxicity data, a preliminary environmental risk assessment of PFA, PAA and ClO2 for CSO disinfection...

  1. FSI-based Overflow Assessment of the Seismically-Isolated SFP with Fuel Racks

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Gil Y.; Park, Hyun T.; Chang, Soo-Hyuk [Korea Maintenance Co., Seoul (Korea, Republic of); Lee, Sang-Hoon [KEPCO E-C, Yongin (Korea, Republic of)

    2014-10-15

    To date, effectiveness of the seismic isolation systems for reducing seismic force effectively has been well demonstrated. In this context, practical application of the technology in nuclear engineering fields has become an important issue more and more. This is because fluid motion can be rather amplified due to the increased relative displacement between the base and superstructures by a long-period shift. Therefore, overflow assessment and prediction of the seismically-isolated SFP have to be conducted in design phase. For performing sloshing-induced overflow of the seismically-isolated SFP, a fluid-structure interaction(FSI) approach making a two-way coupling process between structural and fluid solvers is herein employed. In this study, fuel racks inside the SFP are included in FSI modeling to investigate effect of fuel-cell assemblies on SFP overflow. Accordingly, three different assembly sets of fuel cells are assumed to be inserted in fuel racks. In addition, floor acceleration time-histories produced from three different amplitudes of peak ground acceleration (PGA) are applied to the SFP base to investigate load effect on liquid overflow. An approach for the liquid overflow assessment of the seismically-isolated nuclear SFP with fuel storage racks based on FSI analysis was addressed. From the results of the identified cases, the following conclusions are drawn: (i) FSI technique can be effectively used to assess the seismically-isolated SFP overflow, (ii) In a conservative way, the isolated SFP without fuel racks can be used to assess its sloshing-induced overflow under earthquake since effect of fuel-cell assemblies on the SFP overflow is not significant, (iii) for given same conditions (e.g., constant design free surface, same fuel-cell assembly) except seismic loading, the higher PGA is, the more liquid overflow increases.

  2. Multi-element sewer slime impact pattern--a quantitative characteristic enabling identification of the source of heavy metal discharges into sewer systems.

    Science.gov (United States)

    Kintrup, J; Wünsch, G

    2001-11-01

    The capability of sewer slime to accumulate heavy metals from municipal wastewater can be exploited to identify the sources of sewage sludge pollution. Former investigations of sewer slime looked for a few elements only and could, therefore, not account for deviations of the enrichment efficiency of the slime or for irregularities from sampling. Results of ICP-MS multi element determinations were analyzed by multivariate statistical methods. A new dimensionless characteristic "sewer slime impact" is proposed, which is zero for unloaded samples. Patterns expressed in this data format specifically extract the information required to identify the type of pollution and polluter quicker and with less effort and cost than hitherto.

  3. The Ecology of Acidophilic Microorganisms in the Corroding Concrete Sewer Environment

    Directory of Open Access Journals (Sweden)

    Guangming Jiang

    2017-04-01

    Full Text Available Concrete corrosion is one of the most significant problems affecting valuable sewer infrastructure on a global scale. This problem occurs in the aerobic zone of the sewer, where a layer of surface corrosion develops on the exposed concrete and the surface pH is typically lowered from around 11–10 (pristine concrete to pH 2–4. Acidophilic microorganisms become established as biofilms within the concrete corrosion layer and enhance the loss of concrete mass. Until recently, the acidophilic community was considered to comprise relatively few species of microorganisms, however, the biodiversity of the corrosion community is now recognized as being extensive and varying from different sewer environmental conditions. The diversity of acidophiles in the corrosion communities includes chemolithoautotrophs, chemolithoheterotrophs, and chemoorganoheterotrophs. The activity of these microorganisms is strongly affected by H2S levels in the sewer gas phase, although CO2, organic matter, and iron in the corrosion layer influence this acidic ecosystem. This paper briefly presents the conditions within the sewer that lead to the development of concrete corrosion in that environment. The review focuses on the acidophilic microorganisms detected in sewer corrosion environments, and then summarizes their proposed functions and physiology, especially in relation to the corrosion process. To our knowledge, this is the first review of acidophilic corrosion microbial communities, in which, the ecology and the environmental conditions (when available are considered. Ecological studies of sewer corrosion are limited, however, where possible, we summarize the important metabolic functions of the different acidophilic species detected in sewer concrete corrosion layers. It is evident that microbial functions in the acidic sewer corrosion environment can be linked to those occurring in the analogous acidic environments of acid mine drainage and bioleaching.

  4. Environmental Assessment (EA) for Replacement of the Wastewater Lift Station (Building 510)

    Science.gov (United States)

    2013-04-13

    ensure that wastewater from FEW continues to be safely and efficiently moved to the City of Cheyenne sanitary sewer system. The lift station is...from four to six inches. The subsoil is primarily alluvial clay that extends from a depth of approximately 6 to 36 inches. 8.4. Air Quality. Under...Disposal 8.6.1. Sanitary Sewer System A National Pollutant Discharge Elimination System (NPDES) permit issued by the WYDEQ is in place to allow discharge

  5. Final Environmental Assessment (EA) for Replacement of the Wastewater Lift Station (Building 510)

    Science.gov (United States)

    2013-03-01

    ensure that wastewater from FEW continues to be safely and efficiently moved to the City of Cheyenne sanitary sewer system. The lift station is...from four to six inches. The subsoil is primarily alluvial clay that extends from a depth of approximately 6 to 36 inches. 8.4. Air Quality. Under...Disposal 8.6.1. Sanitary Sewer System A National Pollutant Discharge Elimination System (NPDES) permit issued by the WYDEQ is in place to allow discharge

  6. KC-46A Formal Training Unit (FTU) and First Main Operating Base (MOB 1) Beddown EIS. Volume 1

    Science.gov (United States)

    2014-03-01

    discharged into the sanitary sewer system. Most of the sanitary sewer system at Altus AFB is over 45 years old and constructed of vitrified clay ...drained (USDA 2002a, 2003). The textures of the Tillman-Hollister soils range from clay loam to clay , with the Hollister subsurface soils being more clayey...range from sandy to sandy loam to sandy clay loam, with the Nobscot soils having a more sandy nature, especially in the surface soils (Altus AFB 2009a

  7. Bioaugmentation for Aerobic Bioremediation of RDX-Contaminated Groundwater

    Science.gov (United States)

    2016-06-01

    sampling. The surface soil is characterized as a sandy loam soil (78% sand, 6% silt, 16% clay ) with a pH of 8.4, an organic carbon content of < 0.1...biomass is disposed of according to local ordinances (e.g., sterilized and directed into a municipal sanitary sewer). E.3. Use Information and...sterilized and directed into a municipal sanitary sewer). E.3. Use Information and Consumer Exposure Cultures are being used solely for field

  8. Water Hammer in Pumped Sewer Mains

    DEFF Research Database (Denmark)

    Larsen, Torben

    of transients in pumped pipeline systems. This present publication can be understood as the second and revised edition of the pamphlet ”Transients in pumped sewer mains” (2006) which was published as a technical report by The EVA committee under The Danish Water Pollution Committee (The Danish Society......This publication is intended for students and engineers seeking an introduction to the problem of water transients in pumped sewer and water mains. This is a subject of increasing interest because of the development of larger and more integrated systems. Consideration of transients is essential...

  9. Oahu Sewer Manhole Points, Oahu County HI, 2016, Honolulu GIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — Point features representing sewer manholes as maintained by Honolulu ENV Department of Environmental Services. This inventory of sewer manholes used by tracking,...

  10. Oahu Sewer Lateral Lines, Oahu County HI, 2016, Honolulu GIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — Inventory of sewer laterals, used for tracking, monitoring, and flow analysis as maintained by Honolulu ENV Department of Environmental Services. The base sewer...

  11. Oahu Sewer Main Lines, Oahu County HI, 2016, Honolulu GIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — Linear features representing sewer main lines as maintained by Honolulu ENV Department of Environmental Services. Includes an inventory of sewer mains used for...

  12. Impacts on sewer performance due to changes to inputs in domestic wastewater

    OpenAIRE

    Mattsson, Jonathan

    2015-01-01

    The impacts of changes in domestic wastewater inputs on sewer performance have been debated since the dawn of the great sewer construction movement in the 1850s. Nowadays, typical household wastewater that enters sewers can generally be divided into streams from the WC, shower and/or bathtub, kitchen sink, washing machine and dishwasher. Changes in thecomposition of domestic wastewater entering a sewer will depend on inter alia the properties of the appliances used in the households and house...

  13. Sanitary Landfill Supplemental Test Final Report

    International Nuclear Information System (INIS)

    Altman, D.J.

    1999-01-01

    This report summarizes the performance of the Sanitary Landfill Supplemental Test data, an evaluation of applicability, conclusions, recommendations, and related information for implementation of this remediation technology at the SRS Sanitary Landfill

  14. Multi-element sewer slime impact pattern - a quantitative characteristic enabling identification of the source of heavy metal discharges into sewer systems

    Energy Technology Data Exchange (ETDEWEB)

    Kintrup, J. [Chemistry Lab., Wessling GmbH, Hannover (Germany); Wuensch, G. [Lehrgebiet Analytische Chemie, Univ. Hannover (Germany)

    2001-11-01

    The capability of sewer slime to accumulate heavy metals from municipal wastewater can be exploited to identify the sources of sewage sludge pollution. Former investigations of sewer slime looked for a few elements only and could, therefore, not account for deviations of the enrichment efficiency of the slime or for irregularities from sampling. Results of ICP-MS multi element determinations were analyzed by multivariate statistical methods. A new dimensionless characteristic ''sewer slime impact'' is proposed, which is zero for unloaded samples. Patterns expressed in this data format specifically extract the information required to identify the type of pollution and polluter quicker and with less effort and cost than hitherto. (orig.)

  15. Optimal Design of Gravitational Sewer Networks with General Cellular Automata

    Directory of Open Access Journals (Sweden)

    Mohammad Hadi Afshar

    2014-05-01

    Full Text Available In this paper, a Cellular Automata method is applied for the optimal design of sewer networks. The solution of sewer network optimization problems requires the determination of pipe diameters and average pipe cover depths, minimizing the total cost of the sewer network subject to operational constraints. In this paper, the network nodes and upstream and downstream pipe cover depths are considered as CA cells and cell states, respectively, and the links around each cell are taken into account as neighborhood. The proposed method is a general and flexible method for the optimization of sewer networks as it can be used to optimally design both gravity and pumped network due to the use of pipe nodal cover depths as the decision variables. The proposed method is tested against two  gravitational sewer networks and the  comparison of results with other methods such as  Genetic algorithm, Cellular Automata, Ant Colony Optimization Algorithm and Particle Swarm Optimization show the efficiency and effectiveness of the proposed method.

  16. A methodological approach to designing sewer system control

    DEFF Research Database (Denmark)

    Mollerup, Ane Loft

    for this thesis was therefore the wish for a methodological approach to sewer system control design. Using a case study the following research hypothesis was tested in this thesis: Using classical and modern control theory, a methodological approach can be derived for designing sewer system control. This can aid....... This was not unexpected, since the true potential of having optimisation arises, when a system has many control loops with limit-ing constraints and/or changing prioritisation between them. The results showed that for small sewer systems, where the complexity is limited, it is not necessarily the best option to implement...... generate control systems of the future that are more robust, more structured, have a better performance and are easi-er to maintain....

  17. Searching for storm water inflows in foul sewers using fibre-optic distributed temperature sensing.

    Science.gov (United States)

    Schilperoort, Rémy; Hoppe, Holger; de Haan, Cornelis; Langeveld, Jeroen

    2013-01-01

    A major drawback of separate sewer systems is the occurrence of illicit connections: unintended sewer cross-connections that connect foul water outlets from residential or industrial premises to the storm water system and/or storm water outlets to the foul sewer system. The amount of unwanted storm water in foul sewer systems can be significant, resulting in a number of detrimental effects on the performance of the wastewater system. Efficient removal of storm water inflows into foul sewers requires knowledge of the exact locations of the inflows. This paper presents the use of distributed temperature sensing (DTS) monitoring data to localize illicit storm water inflows into foul sewer systems. Data results from two monitoring campaigns in foul sewer systems in the Netherlands and Germany are presented. For both areas a number of storm water inflow locations can be derived from the data. Storm water inflow can only be detected as long as the temperature of this inflow differs from the in-sewer temperatures prior to the event. Also, the in-sewer propagation of storm and wastewater can be monitored, enabling a detailed view on advection.

  18. Urban Stormwater Infiltration Perspectives

    DEFF Research Database (Denmark)

    Geldof, Govert; Jacobsen, Per; Fujita, Shoichi

    1994-01-01

    In urban areas there are many problems with water management: combined sewer overflows, peak flows, man-induced droughts, consolidation of the soil, damage from frost penetration, etc. It is preferable to look at all these problems in relation to each other, according the concept of integrated...... water management. This paper focuses on the possibilities for urban stormwater infiltration. The results of three studies are presented. The first study concerns the flooding of the Shirako River in Tokyo. It is shown that with the help of stormwater infiltration the floods can be reduced remarkably....... The second study concerns combined sewer overflows and the discharge from treatment plants for catchments in Denmark and the Netherlands. When looking at the total yearly discharge from the combined sewer and the treatment plant, it is shown that infiltration is more effective than detention. The third study...

  19. Soil-biofilters for elimination of xenobiotics from wastewaters

    DEFF Research Database (Denmark)

    Bester, Kai; Schäfer, D; Janzen, N.

    treatment plants are not designed to eliminate these compounds. Even more of these compounds are discharged by storm waters and combined sewer overflows. It is generally suggested that separating sewers into waste water and rainwater systems might help to improve the situation. However in the last few years...... it has been demonstrated, that storm waters can be heavily polluted with biocides, lubricants and PAHs. In this study we investigated the possibilities to eliminate lipophilic fragrances, bactericides, UV blockers, lubricants etc, as well as more hydrophilic organophosphate flame retardants, biocides...... and other components with low cost soil biofilter techniques suited for on-site decentralised treatment of storm waters and combined sewer overflows. On the other hand the same systems and compounds were tested in for polishing treated waste water in respect of further elimination of xenobiotic compounds....

  20. Very large eddy simulation of the Red Sea overflow

    Science.gov (United States)

    Ilıcak, Mehmet; Özgökmen, Tamay M.; Peters, Hartmut; Baumert, Helmut Z.; Iskandarani, Mohamed

    Mixing between overflows and ambient water masses is a critical problem of deep-water mass formation in the downwelling branch of the meridional overturning circulation of the ocean. Modeling approaches that have been tested so far rely either on algebraic parameterizations in hydrostatic ocean circulation models, or on large eddy simulations that resolve most of the mixing using nonhydrostatic models. In this study, we examine the performance of a set of turbulence closures, that have not been tested in comparison to observational data for overflows before. We employ the so-called very large eddy simulation (VLES) technique, which allows the use of k-ɛ models in nonhydrostatic models. This is done by applying a dynamic spatial filtering to the k-ɛ equations. To our knowledge, this is the first time that the VLES approach is adopted for an ocean modeling problem. The performance of k-ɛ and VLES models are evaluated by conducting numerical simulations of the Red Sea overflow and comparing them to observations from the Red Sea Outflow Experiment (REDSOX). The computations are constrained to one of the main channels transporting the overflow, which is narrow enough to permit the use of a two-dimensional (and nonhydrostatic) model. A large set of experiments are conducted using different closure models, Reynolds numbers and spatial resolutions. It is found that, when no turbulence closure is used, the basic structure of the overflow, consisting of a well-mixed bottom layer (BL) and entraining interfacial layer (IL), cannot be reproduced. The k-ɛ model leads to unrealistic thicknesses for both BL and IL, while VLES results in the most realistic reproduction of the REDSOX observations.

  1. Modeling Sulfides, pH and Hydrogen Sulfide Gas in the Sewers of San Francisco

    DEFF Research Database (Denmark)

    Vollertsen, Jes; Revilla, Nohemy; Hvitved-Jacobsen, Thorkild

    2015-01-01

    An extensive measuring campaign targeted on sewer odor problems was undertaken in San Francisco. It was assessed whether a conceptual sewer process model could reproduce the measured concentrations of total sulfide in the wastewater and H2S gas in the sewer atmosphere, and to which degree...... such simulations have potential for further improving odor and sulfide management. The campaign covered measurement of wastewater sulfide by grab sampling and diurnal sampling, and H2S gas in the sewer atmosphere was logged. The tested model was based on the Wastewater Aerobic/Anaerobic Transformations in Sewers...... (WATS) sewer process concept, which never had been calibrated to such an extensive dataset. The study showed that the model was capable of reproducing the general levels of wastewater sulfide, wastewater pH, and sewer H2S gas. It could also reproduce the general variability of these parameters, albeit...

  2. Tree root intrusion in sewer systems: A review of extent and costs

    Science.gov (United States)

    T.B. Randrup; E.G. McPherson; L.R. Costello

    2001-01-01

    Interference between trees and sewer systems is likely to occur in old systems and in cracked pipes. Factors that contribute to damage include old pipes with joints, shallow pipes, small-dimension pipes, and fast-growing tree species. Because roots are reported to cause >50% of all sewer blockages, costs associated with root removal from sewers is substantial. In...

  3. COMBINED AND STORM SEWER NETWORK MONITORING

    Directory of Open Access Journals (Sweden)

    Justyna Synowiecka

    2014-10-01

    Full Text Available Monitoring of the drainage networks is an extremely important tool used to understand the phenomena occurring in them. In an era of urbanization and increased run-off, at the expense of natural retention in the catchment, it helps to minimize the risk of local flooding and pollution. In its scope includes measurement of the amount of rainfall, with the use of rain gauges, and their measure in the sewer network, in matter of flows and channel filling, with the help of flow meters. An indispensable part in this step is their proper calibration calibration. In addition to ongoing monitoring of the sewer system, periodic inspections by the qualified employees of Water and Sewage Company should be done. The following article reviews measurement devices, their calibration methods, as well as the phenomena that occur during operation in the sewer network. It provides a solution for monitoring and control based on the experience of the Municipal Water and Sewage Company in Wroclaw, describing common operational problems, their causes, prevention methods and a network operation walkthrough with the improve of performance indicators KPI (Key Performance Indicators according the ECB (European Benchmarking Co-operation.

  4. New Findings in Hydrogen Sulfide Related Corrosion of Concrete Sewers

    DEFF Research Database (Denmark)

    Nielsen, Asbjørn Haaning; Jensen, Henriette Stokbro; Hvitved-Jacobsen, Thorkild

    2009-01-01

    This paper summarizes major findings of a long-term study of hydrogen sulfide gas (H2S) adsorption and oxidation on concrete and plastic sewer pipe surfaces. The processes have been studied using a pilot-scale setup designed to replicate conditions in a gravity sewer located downstream of a force...... main. H2S related concrete corrosion and odor is often observed at such locations. The experiments showed that the rate of H2S oxidation was significantly faster on concrete pipe surfaces than on plastic pipe surfaces. Steady state calculations based on the kinetic data demonstrated that the gas phase...... H2S concentration in concrete sewers would typically amount to a few percent of the equilibrium concentration calculated from Henrys law. In plastic pipe sewers, significantly higher concentrations were predicted because of the slower adsorption and oxidation kinetics on these surfaces. Finally...

  5. RTC simulations on large branched sewer systems with SmaRTControl.

    Science.gov (United States)

    de Korte, Kees; van Beest, Dick; van der Plaat, Marcel; de Graaf, Erno; Schaart, Niels

    2009-01-01

    In The Netherlands many large branched sewer systems exist. RTC can improve the performance of these systems. The objective of the universal algorithm of SmaRTControl is to improve the performance of the sewer system and the WWTP. The effect of RTC under rain weather flow conditions is simulated using a hydrological model with 19 drainage districts. The system related inefficiency coefficient (SIC) is introduced for assessment of the performance of sewer systems. The performance can be improved by RTC in combination with increased pumping capacities in the drainage districts, but without increasing the flow to the WWTP. Under dry weather flow conditions the flow to the WWTP can be equalized by storage of wastewater in the sewer system. It is concluded that SmaRTControl can improve the performance, that simulations are necessary and that SIC is an excellent parameter for assessment of the performance.

  6. A Riccati model for Denmark Strait overflow variability

    Science.gov (United States)

    Käse, R. H.

    2006-10-01

    A controlled volume box model of the western basins of the Nordic Seas for water denser than 1027.8 kg m-3 is constructed, where accumulation in volume ($\\frac{dV}{dt) is driven by net imbalances between prescribed net inflow from the northern, eastern and top boundaries (Qs) and hydraulically limited outflow through the Denmark Strait. The resulting Riccati equation is solved analytically for filling and flushing experiments with constant Qs and numerically for stochastic forcing Qs(t). For small perturbations to Qs with white noise spectrum, the overflow response is red noise with a time scale between 5 and 15 years depending on the mean interface height and area. For Qs proportional to the NAO index, the overflow is positively correlated with the NAO. A 140 years integration reveals variations in the overflow between 2.5 Sv in the 1970s and a maximum of 4 Sv in the 1990s. Hydraulic transport calculations from hydrographic data north of Iceland show good agreement with the model hindcast.

  7. 21 CFR 1210.14 - Sanitary inspection of plants.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sanitary inspection of plants. 1210.14 Section... FEDERAL IMPORT MILK ACT Inspection and Testing § 1210.14 Sanitary inspection of plants. The sanitary conditions of any plant handling milk or cream any part of which is to be shipped or transported into the...

  8. Recent findings on sinks for sulfide in gravity sewer networks

    DEFF Research Database (Denmark)

    Nielsen, Asbjørn Haaning; Hvitved-Jacobsen, Thorkild; Vollertsen, Jes

    2006-01-01

    summarizes this newly obtained knowledge and emphasizes important implications of the findings. Model simulations of the in-sewer processes important for the sulfur cycle showed that sulfide oxidation in the wetted biofilm is typically the most important sink for dissolved sulfide in gravity sewers. However...

  9. Improved Secret Image Sharing Scheme in Embedding Capacity without Underflow and Overflow.

    Science.gov (United States)

    Pang, Liaojun; Miao, Deyu; Li, Huixian; Wang, Qiong

    2015-01-01

    Computational secret image sharing (CSIS) is an effective way to protect a secret image during its transmission and storage, and thus it has attracted lots of attentions since its appearance. Nowadays, it has become a hot topic for researchers to improve the embedding capacity and eliminate the underflow and overflow situations, which is embarrassing and difficult to deal with. The scheme, which has the highest embedding capacity among the existing schemes, has the underflow and overflow problems. Although the underflow and overflow situations have been well dealt with by different methods, the embedding capacities of these methods are reduced more or less. Motivated by these concerns, we propose a novel scheme, in which we take the differential coding, Huffman coding, and data converting to compress the secret image before embedding it to further improve the embedding capacity, and the pixel mapping matrix embedding method with a newly designed matrix is used to embed secret image data into the cover image to avoid the underflow and overflow situations. Experiment results show that our scheme can improve the embedding capacity further and eliminate the underflow and overflow situations at the same time.

  10. 9 CFR 416.4 - Sanitary operations.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Sanitary operations. 416.4 Section 416... SANITATION § 416.4 Sanitary operations. (a) All food-contact surfaces, including food-contact surfaces of... compounds, sanitizing agents, processing aids, and other chemicals used by an establishment must be safe and...

  11. [Sanitary education of workers of bakeries and pastry enterprises].

    Science.gov (United States)

    Krasil'shchikov, M I; Nemets, M G; Novikova, O V; Gavrilenko, E V; Osipova, E M; Osinova, T I

    2000-01-01

    The paper presents experience with sanitary education of workers from food industrial enterprises. The study revealed a number of disadvantages of the methodological aspect of sanitary education of these workers. A sanitary education programme has been worked out for workers engaged in food and food processing industries (production of bread, baked goods, and confectionery) and approved by the State Sanitary and Epidemiological Surveillance Department), Ministry of Health of Russia on March 1999.

  12. [Transport and sources of runoff pollution from urban area with combined sewer system].

    Science.gov (United States)

    Li, Li-Qing; Yin, Cheng-Qing

    2009-02-15

    Sampling and monitoring of runoff and sewage water in Wuhan urban area with combined sewer system were carried out during the period from 2003 to 2006, to study the transport and sources of runoff pollution at the catchment scale coupled with environmental geochemistry method. The results showed a change in quality between the runoff entering the sewer network and the combined storm water flow at the sewer's outlet. A significant increase was observed in the concentrations of total suspended solids (TSS), volatile suspended solids (VSS), COD, TN, and TP, and in the proportion of COD linked to particles. During the runoff production and transport, the concentrations of TSS and COD increased from 18.7 mg/L and 37.0 mg/L in roof runoff, to 225.3 mg/L and 176.5 mg/L in street runoff, and to 449.7 mg/L and 359.9 mg/L in combined storm water flow, respectively. The proportion of COD linked to particles was increased by 18%. In addition, the total phosphorus (P) and iron (Fe) contents in urban ground dust, storm drain sediment, sewage sewer sediment and combined sewer sediment were measured to identify the potential sources of suspended solids in the combined flow. The urban ground dust andstorm drain sediment wererich in Fe, whereas the sewage sewer sediment was rich in P. The P/Fe ratios in these groups were significantly distinct and able to differentiate them. A calculation of the two storm events based on the P/Fe rations showed that 56% +/- 26% of suspended solids in combined flow came from urban ground and storm drain. The rest wer e originated from the sewage sewer sediments which deposited in combined sewer on the dry weather days and were eroded on the wet weather days. The combined sewer network not only acts as a transport system, but also constitutes a physicochemical reactor that degrades the quality of urban water. Reducing the in-sewer pollution stocks would effectively control urban runoff pollution.

  13. The Historical Development of Sewers Worldwide

    Directory of Open Access Journals (Sweden)

    Giovanni De Feo

    2014-06-01

    Full Text Available Although there is evidence of surface-based storm drainage systems in early Babylonian and Mesopotamian Empires in Iraq (ca. 4000–2500 BC, it is not until after ca. 3000 BC that we find evidence of the well organized and operated sewer and drainage systems of the Minoans and Harappans in Crete and the Indus valley, respectively. The Minoans and Indus valley civilizations originally, and the Hellenes and Romans thereafter, are considered pioneers in developing basic sewerage and drainage technologies, with emphasis on sanitation in the urban environment. The Hellenes and Romans further developed these techniques and greatly increased the scale of these systems. Although other ancient civilizations also contributed, notably some of the Chinese dynasties, very little progress was made during the Dark ages from ca. 300 AD through to the middle of the 18th century. It was only from 1850 onwards that that modern sewerage was “reborn”, but many of the principles grasped by the ancients are still in use today. This paper traces the development of the sewer from those earliest of civilizations through to the present day and beyond. A 6000 year technological history is a powerful validation of the vital contribution of sewers to human history.

  14. [Pollution Characteristics of Surface Runoff of Typical Town in Chongqing City].

    Science.gov (United States)

    Wang, Long-tao; Duan, Bing-zheng; Zhao, Jian-wei; Hua, Yu-mei; Zhu, Duan-wei

    2015-08-01

    Six kinds of impermeable underlying surface, cement tile roof, asbestos roof, cement flat roof, residential concrete pavement, asphalt pavement of restaurants, asphalt pavement of oil depot, and a combined sewer overflow canal in the Jiansheng town of Dadukou district in Chongqing city were chosen as sample plots to study the characteristics of nutritional pollutants and heavy metals in town runoff. The research showed that the average mass concentrations of TSS, COD, TN, TP in road runoff were (1681.2 +/- 677.2), (1154.7 +/- 415.5), (12.07 +/- 2.72), (3.32 +/- 1.15) mgL(-1), respectively. These pollutants were higher than those in roof runoff which were (13.3 +/- 6.5), (100.4 +/- 24.8), (3.58 +/- 0.70), (0.10 +/- 0.02) mg x L(-1), respectively. TDN accounted for 62.60% +/- 34.38% of TN, and TDP accounted for 42.22% +/- 33.94% of TP in the runoff of impermeable underlying surface. Compared with the central urban runoff, town runoff in our study had higher mass concentrations of these pollutants. The mass concentrations of TSS, COD, TDN, TN, TDP and TP in the combined sewer overflow were (281.57 +/- 308.38), (231.21 +/- 42.95), (8.16 +/- 2.78), (10.60 +/- 3.94), (0.38 +/- 0.23) and (1.51 +/- 0.75) mg x L(-1), respectively. The average levels of heavy metals in this kind of runoff did not exceed the class VI level of the surface water environmental quality standard. Most pollutants in the combined sewer overflow had first flush. However, this phenomenon was very rare for TSS. There was a significant positive correlation between TSS and COD, TP in the combined sewer overflow. And this correlation was significant between NH4+ -N and TP, TDP, TN, TDP. However, a negative correlation existed between NO3- -N and all other indicators.

  15. Dynamic gauge adjustment of high-resolution X-band radar data for convective rain storms: Model-based evaluation against measured combined sewer overflow

    DEFF Research Database (Denmark)

    Borup, Morten; Grum, Morten; Linde, Jens Jørgen

    2016-01-01

    estimates through a hydraulic urban drainage model. The model is built entirely from physical data, without any calibration, to avoid bias towards any specific type of rainfall estimate. The performance is assessed by comparing measured and modelled water levels at a weir downstream of a highly impermeable......Numerous studies have shown that radar rainfall estimates need to be adjusted against rain gauge measurements in order to be useful for hydrological modelling. In the current study we investigate if adjustment can improve radar rainfall estimates to the point where they can be used for modelling...... overflows from urban drainage systems, and we furthermore investigate the importance of the aggregation period of the adjustment scheme. This is done by continuously adjusting X-band radar data based on the previous 5–30 min of rain data recorded by multiple rain gauges and propagating the rainfall...

  16. Roche-Lobe overflow in X-ray binaries, ch. 2

    International Nuclear Information System (INIS)

    Savonije, G.J.

    1977-01-01

    It is examined whether Roche-lobe overflow can be the main mechanism of mass transfer that powers the low-mass as well as the massive X-ray binaries. Detailed numerical computations of the initial phase of Roche-lobe overflow were performed in order to determine the precise time development of the mass transfer from normal stars with masses ranging from 1.5 M(sun) up to 20 M(sun) to compact companions with masses of 1 and 1.5 M(sun). The binary code includes a simplified hydrodynamical treatment of Roche-lobe overflow. For massive primaries this hydrodynamical treatment appears to result in much longer X-ray lifetimes than obtained in previous investigations. The calculations also include effects of slow, non-synchronous rotation of the contact star and loss of mass and angular momentum from the binary system. For Her X-1 and Cen X-3 X-ray lifetimes of the order of 10 5 and 10 4 yrs are predicted, respectively

  17. Principles and Approaches for Numerical Modelling of Sediment Transport in Sewers

    DEFF Research Database (Denmark)

    Mark, Ole; Appelgren, Cecilia; Larsen, Torben

    1995-01-01

    A study has been carried out with the objectives of describing the effect of sediment deposits on the hydraulic capacity of sewer systems and to investigate the sediment transport in sewer systems. A result of the study is a mathematical model MOUSE ST which describes sediment transport in sewers....... This paper discusses the applicability and the limitations of various modelling approaches and sediment transport formulations in in MOUSE ST. Further, the paper presents a simple application of MOUSE ST to the Rya catchment in Gothenburg, Sweden....

  18. Optimization of the central automatic control of a small Dutch sewer system

    Science.gov (United States)

    Kolechkina, A. G.; Hoes, O. A. C.

    2012-04-01

    A sewer control system was developed in the context of a subsidized project aiming at improvement of surface water quality by control of sewer systems and surface water systems. The project was coordinated by the local water board, "Waterschap Hollandse Delta". Other participants were Delft University of Technology, Deltares and the municipalities Strijen, Cromstrijen, Westmaas, Oud Beijerland and Piershil. As part of the project there were two pilot implementations where a central automatic controller was coupled to the existing SCADA system. For these two pilots the system is now operational. A Dutch urban area in the western part of the Netherlands is usually part of a polder, which is effectively an artificially drained catchment. The urban area itself is split into small subcatchments that manage runoff in different ways. In all cases a large fraction goes into the natural hydrological cycle, but, depending on the design of the local sewer system, a larger or smaller part finds its way into the sewer system. Proper control of this flow is necessary to control surface water quality and to avoid health risks from flow from the sewer into the streets. At each time step the controller switches pumps to distribute the remaining water in the system at the end of the time step over the different subcatchments. The distribution is created based on expert judgment of the relative vulnerability and subcatchment sewer system water quality. It is implemented in terms curves of total system stored volume versus subcatchment stored volume. We describe the process of the adaptation of a controller to two different sewer systems and the understanding of the artificial part of the catchment we gained during this process. In the process of adaptation the type of sewer system (combined foul water and storm water transport or separate foul water and storm water transport) played a major role.

  19. A novel method for rapid inspection of sewer networks: combining acoustic and optical means

    OpenAIRE

    Plihal, H.; Kretschmer, F.; Bin Ali, M.T.; See, C.H.; Romanova, A.; Horoshenkov, K.V.; Ertl, T.

    2015-01-01

    Operation and maintenance of the public sewer system represent key tasks for an\\ud operator. Condition assessment is usually conducted by conventional closed\\ud circuit television (CCTV) inspection. However, alternative tools such as\\ud manhole-zoom cameras (MZCs) and the acoustic technology SewerBatt® are\\ud available today.\\ud The INNOKANIS project investigates structural and operational condition\\ud assessment in the sewer system by means of 3 MZC models and SewerBatt® to\\ud develop a comb...

  20. Anticoagulant resistance: a relevant issue in sewer rat (Rattus norvegicus) control?

    DEFF Research Database (Denmark)

    Heiberg, Ann-Charlotte

    2009-01-01

    the resistant rats, had resistance-related mutations in the VKORC1 gene. CONCLUSION: The results of this study suggest that the genetic background of anticoagulant resistance may have to be redefined in respect of resistance-related changes in the VKORC1 gene. Copyright © 2009 Society of Chemical Industry......BACKGROUND: The majority of rat problems in cities are thought to be related to defective sewers, and the use of anticoagulant rodenticides in such places is often implemented as part of regular urban rodent control. Knowledge pertaining to the resistance status of sewer rat populations is non......-existent, which may be leading to control problems in cities. It has become crucial to provide knowledge on the prevalence of resistance and how different control strategies have affected its prevalence among sewer rat populations. The prevalence of resistance was investigated in six sewer locations in Copenhagen...

  1. Principles and approaches for numerical modelling of sediment transport in sewers

    DEFF Research Database (Denmark)

    Mark, Ole; Larsen, Torben; Appelgren, Cecilia

    1994-01-01

    model MOUSE ST which describes the sediment transport in sewers. This paper discusses the applicability and the limitations of various modelling approaches and sediment transport formulations in MOUSE ST. The study was founded by the Swedish Water and Waste Works Association and the Nordic Industrial......A study has been carried out at the University of Aalborg, Denmark and VBB VIAK, Sweden with the objectives to describe the effect of sediment deposits on the hydraulic capacity of sewer systems and to investigate the sediment transport in sewer systems. A results of the study is a mathematical...

  2. Interface dilation : the overflowing cylinder technique

    NARCIS (Netherlands)

    Bergink - Martens, D.J.M.

    1993-01-01

    A pure steady-state dilation of a liquid interface, either liquid-air or water-oil, can be accomplished far from equilibrium by means of the overflowing cylinder technique. The resulting dynamic surface tension data correlate well with characteristic parameters of processes like foaming,

  3. Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex

    Science.gov (United States)

    The role of sewer lines as preferential pathways for vapor intrusion is poorly understood. Although the importance of sewer lines for volatile organic compound (VOC) transport has been documented at a small number of sites with vapor intrusion, sewer lines are not routinely sampl...

  4. Radar Based Flow and Water Level Forecasting in Sewer Systems

    DEFF Research Database (Denmark)

    Thorndahl, Søren; Rasmussen, Michael R.; Grum, M.

    2009-01-01

    This paper describes the first radar based forecast of flow and/or water level in sewer systems in Denmark. The rainfall is successfully forecasted with a lead time of 1-2 hours, and flow/levels are forecasted an additional ½-1½ hours using models describing the behaviour of the sewer system. Bot...

  5. Searching for storm water inflows in foul sewers using fibre-optic distributed temperature sensing

    NARCIS (Netherlands)

    Schilperoort, R.; Hoppe, H.; Haan, C.; Langeveld, J.G.

    2012-01-01

    A major drawback of separate sewer systems is the occurrence of illicit connections: unintended sewer cross-connections that connect foul water outlets from residential or industrial premises to the storm water system and/or storm water outlets to the foul sewer system. The amount of unwanted storm

  6. Cold Vacuum Drying facility sanitary sewage collection system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) sanitary sewage collection system. The sanitary sewage collection system provides collection and storage of effluents and raw sewage from the CVDF to support the cold vacuum drying process. This system is comprised of a sanitary sewage holding tank and pipes for collection and transport of effluents to the sanitary sewage holding tank

  7. Interactions between heavy metals and sewer slimes. Wechselwirkungen zwischen Schwermetallen und Sielhaut

    Energy Technology Data Exchange (ETDEWEB)

    Gutekunst, B.

    1989-09-01

    Sewer slimes in wastewater pipes are an efficient means for detecting heavy metals discharged into the sewer system. The chances and limits of this method are discussed on the basis of the interactions between the heavy metals and the sewer slime. Chemical processes which lead to an accumulation of heavy metals are precipitation, adsorption and sedimentation. The mobilization is due to dissolution, desorption and complexation. The dependency of the waste water parameters pH, redox potential, heavy metal concentration and speciation on the accumulation and mobilization of the heavy metals is investigated as well as the binding capacity and strength. The heavy metals speciations in sewer slime are estimated by the application of a sequential leaching technique. Finally the practical significance of the experiments is shown. (orig.).

  8. Determination of an Optimal Trunk Sewer-line Route for Kikuyu ...

    African Journals Online (AJOL)

    The best alternative is a sewerage system that uses sewer-lines to convey sewage into a treatment works. This project seeks to replace the traditional methods currently used in Kikuyu Town with a sewerage system. Geospatial technologies are used to site a treatment plant and the main trunk sewer-line route in Kikuyu ...

  9. Special design issues related to the G. Ross Lord Dam constructed in Metropolitan Toronto

    Energy Technology Data Exchange (ETDEWEB)

    Sowa, V.A. [Jacques Whitford and Associates Ltd., Vancouver, BC (Canada); Tawil, A.H. [Acres International Ltd., Niagara Falls, ON (Canada); Haley, D.R. [Toronto Region and Conservation Authority, Downsview, ON (Canada)

    2002-07-01

    This paper describes the special considerations required to build a flood control dam in a metropolitan area that holds major city infrastructures such as power transmission towers, pipelines, sanitary sewers and graveyards. The paper refers to the G. Ross Lord Dam, a 20 m high earth fill flood control dam which was constructed in 1973 on the West Branch of the Don River in Toronto. It was built following recommendations after Hurricane Hazel caused widespread flooding and the death of 81 people in 1954. The dam includes a concrete chute spillway and stilling basin. The geotechnical design of the dam was described along with the dam structures and the methods used to flood proof the infrastructure. The dam has a sloping impervious core and an upstream blanket to reduce seepage. Seepage control is provided by a drainage blanket and a chimney drain. A main overflow spillway was constructed on the south abutment, and a low level outlet was constructed at the base of the dam to accommodate normal river flows through the dam. Most of the water level control during a flood event is provided by the main overflow spillway. Spillway slab anchor keys prevent down slope creep of the slabs. The dam, the spillway and the reservoir structure have performed well since construction. 6 refs., 10 figs.

  10. 25 CFR 700.55 - Decent, safe, and sanitary dwelling.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Decent, safe, and sanitary dwelling. 700.55 Section 700... PROCEDURES General Policies and Instructions Definitions § 700.55 Decent, safe, and sanitary dwelling. (a) General. The term decent, safe, and sanitary dwelling means a dwelling which— (1) Meets applicable federal...

  11. Characteristics of the Nordic Seas overflows in a set of Norwegian Earth System Model experiments

    Science.gov (United States)

    Guo, Chuncheng; Ilicak, Mehmet; Bentsen, Mats; Fer, Ilker

    2016-08-01

    Global ocean models with an isopycnic vertical coordinate are advantageous in representing overflows, as they do not suffer from topography-induced spurious numerical mixing commonly seen in geopotential coordinate models. In this paper, we present a quantitative diagnosis of the Nordic Seas overflows in four configurations of the Norwegian Earth System Model (NorESM) family that features an isopycnic ocean model. For intercomparison, two coupled ocean-sea ice and two fully coupled (atmosphere-land-ocean-sea ice) experiments are considered. Each pair consists of a (non-eddying) 1° and a (eddy-permitting) 1/4° horizontal resolution ocean model. In all experiments, overflow waters remain dense and descend to the deep basins, entraining ambient water en route. Results from the 1/4° pair show similar behavior in the overflows, whereas the 1° pair show distinct differences, including temperature/salinity properties, volume transport (Q), and large scale features such as the strength of the Atlantic Meridional Overturning Circulation (AMOC). The volume transport of the overflows and degree of entrainment are underestimated in the 1° experiments, whereas in the 1/4° experiments, there is a two-fold downstream increase in Q, which matches observations well. In contrast to the 1/4° experiments, the coarse 1° experiments do not capture the inclined isopycnals of the overflows or the western boundary current off the Flemish Cap. In all experiments, the pathway of the Iceland-Scotland Overflow Water is misrepresented: a major fraction of the overflow proceeds southward into the West European Basin, instead of turning westward into the Irminger Sea. This discrepancy is attributed to excessive production of Labrador Sea Water in the model. The mean state and variability of the Nordic Seas overflows have significant consequences on the response of the AMOC, hence their correct representations are of vital importance in global ocean and climate modelling.

  12. Metabolic engineering of carbon overflow metabolism of Bacillus subtilis for improved N-acetyl-glucosamine production.

    Science.gov (United States)

    Ma, Wenlong; Liu, Yanfeng; Shin, Hyun-Dong; Li, Jianghua; Chen, Jian; Du, Guocheng; Liu, Long

    2018-02-01

    Bacillus subtilis is widely used as cell factories for the production of important industrial biochemicals. Although many studies have demonstrated the effects of organic acidic byproducts, such as acetate, on microbial fermentation, little is known about the effects of blocking the neutral byproduct overflow, such as acetoin, on bioproduction. In this study, we focused on the influences of modulating overflow metabolism on the production of N-acetyl-d-glucosamine (GlcNAc) in engineered B. subtilis. We found that acetoin overflow competes with GlcNAc production, and blocking acetoin overflow increased GlcNAc titer and yield by 1.38- and 1.39-fold, reaching 48.9 g/L and 0.32 g GlcNAc/g glucose, respectively. Further blocking acetate overflow inhibited cell growth and GlcNAc production may be induced by inhibiting glucose uptake. Taken together, our results show that blocking acetoin overflow is a promising strategy for enhancing GlcNAc production. The strategies developed in this work may be useful for engineering strains of B. subtilis for producing other important biochemicals. Copyright © 2017. Published by Elsevier Ltd.

  13. Milwaukee Estuary AOC

    Science.gov (United States)

    The rivers in the Milwaukee estuary in Wisconsin drain into Lake Michigan. Wastewater treatment plants and combined sewer overflows contribute pollution which affects fish and wildlife and recreation.

  14. 21 CFR 1210.11 - Sanitary inspection of dairy farms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sanitary inspection of dairy farms. 1210.11... UNDER THE FEDERAL IMPORT MILK ACT Inspection and Testing § 1210.11 Sanitary inspection of dairy farms. The sanitary conditions of any dairy farm producing milk or cream to be shipped or transported into...

  15. Influence of Sewer Sediments on Flow Friction and Shear Stress Distribution

    DEFF Research Database (Denmark)

    Perrusquia, G.; Petersen, O.; Larsen, Torben

    1995-01-01

    Most sewers contain more or less deposited sediments. The paper discusses the distribution of the boundary shear stresses and the hydraulic resistance in part-full sewer pipes with such deposited sediments. The discussion is based on a series of numerical experiments using a validated numerical...

  16. 7 CFR 1780.57 - Design policies.

    Science.gov (United States)

    2010-01-01

    .... 300f et seq.). (h) Conformity with Federal and State water pollution control standards. No funds shall... pollution control standards. (i) Combined sewers. New combined sanitary and storm water sewer facilities... extensions to existing water systems, leakage shall not exceed limits set by either ASTM or AWWA whichever is...

  17. Output-feedback control of combined sewer networks through receding horizon control with moving horizon estimation

    OpenAIRE

    Joseph-Duran, Bernat; Ocampo-Martinez, Carlos; Cembrano, Gabriela

    2015-01-01

    An output-feedback control strategy for pollution mitigation in combined sewer networks is presented. The proposed strategy provides means to apply model-based predictive control to large-scale sewer networks, in-spite of the lack of measurements at most of the network sewers. In previous works, the authors presented a hybrid linear control-oriented model for sewer networks together with the formulation of Optimal Control Problems (OCP) and State Estimation Problems (SEP). By iteratively solv...

  18. GUIDE BLADE FOR AN OVERFLOW STRUCTURE TO BE PLACED ON A VESSEL

    DEFF Research Database (Denmark)

    2017-01-01

    contact surface (4), the primary contact surface having an edge (2) configured for abutting an overflow structure (100) and at least one free edge, wherein the guide blade is configured for being attachable to a unit to be arrange on or in an inlet (109) of an overflow structure or directly...

  19. Developments in sanitary techniques 2011-2012. Important progress through studies in 2011; Ontwikkelingen sanitaire technieken 2011-2012. Belangrijke vorderingen door studies in 2011

    Energy Technology Data Exchange (ETDEWEB)

    Scheffer, W.

    2011-12-15

    In 2011, new laws and regulations were the main theme in sanitary techniques (ST). Libraries have been updated in the areas of tap water installations and sewer systems of buildings. Some important progress was made in the framework of several ST preliminary studies conducted by TVVL and Uneto-VNI. Still, the start-up of new ST studies and projects in 2012 is lagging behind compared to previous years. [Dutch] Het vakgebied van sanitaire technieken (ST) stond in 2011 vooral in het teken van nieuwe wet- en regelgeving. Zowel op het gebied van leidingwaterinstallaties als riolering van bouwwerken zijn de bibliotheken geactualiseerd. In het kader van enkele ST-voorstudies, uitgevoerd door TVVL en Uneto-VNI zijn belangrijke vorderingen gemaakt. De opstart van nieuwe ST-studies en -projecten in 2012 blijft echter achter ten opzichte van voorgaande jaren.

  20. 76 FR 45617 - Notice of Lodging of the Consent Decree Under the Clean Water Act

    Science.gov (United States)

    2011-07-29

    ..., which resulted in dry weather overflows and numerous basement backups in the homes of residents of... well as implement numerous construction projects aimed at repairing or replacing deteriorating sewers...

  1. Interaction of the Faroe Bank Channel overflow with Iceland Basin intermediate waters

    Science.gov (United States)

    Ullgren, Jenny E.; Fer, Ilker; Darelius, Elin; Beaird, Nicholas

    2014-01-01

    The narrow and deep Faroe Bank Channel (FBC) is an important pathway for cold, dense waters from the Nordic Seas to flow across the Iceland-Scotland ridge into the North Atlantic. The swift, turbulent FBC overflow is associated with strong vertical mixing. Hydrographic profiles from a shipboard survey and two Slocum electric gliders deployed during a cruise in May-June 2012 show an intermediate water mass characterized by low salinity and low oxygen concentration between the upper waters of Atlantic origin and the dense overflow water. A weak low-salinity signal originating north-east of Iceland is discernible at the exit of the FBC, but smeared out by intense mixing. Further west (downstream) marked salinity and oxygen minima are found, which we hypothesize are indicators of a mixture of Labrador Sea Water and Intermediate Water from the Iceland Basin. Water mass characteristics vary strongly on short time scales. Low-salinity, low-oxygen water in the stratified interface above the overflow plume is shown to move along isopycnals toward the Iceland-Faroe Front as a result of eddy stirring and a secondary, transverse circulation in the plume interface. The interaction of low-salinity, low-oxygen intermediate waters with the overflow plume already at a short distance downstream of the sill, here reported for the first time, affects the final properties of the overflow waters through entrainment and mixing.

  2. A Sediment Transport Model for Sewers

    DEFF Research Database (Denmark)

    Mark, Ole; Larsson, Johan; Larsen, Torben

    1993-01-01

    This paper describes a mathematical model for transport processes in sewers. The model consists of three sub models, a surface model for the description of the buildup and the washoff of sediment particles from the surface area, a morphological model and an advection-dispersion model. The model i...... is being developed as a part of a study being carried out at the University of Aalborg, Denmark and VBB VIAK, Sweden. The project is funded by the Swedish Water and Waste Water Works Association and the Nordic Industrial Foundation.......This paper describes a mathematical model for transport processes in sewers. The model consists of three sub models, a surface model for the description of the buildup and the washoff of sediment particles from the surface area, a morphological model and an advection-dispersion model. The model...

  3. Overflow Characteristic of Cylindrical Shape Crest Weirs Over Horizontal Bed

    OpenAIRE

    Emad4 AbdulGabbar

    2013-01-01

    The most common types of weirs are the broad-crested weir, the sharp-crested weir, the circular crested weir and the ogee crested weir. Advantages of the cylindrical weir shape include the stable overflow pattern, the ease to pass floating debris, the simplicity of design compared to ogee crest design and the associated lower costs. In present study, it was investigated the overflow characteristics of circular weirs in laboratory for various cylinder radii of three sizes (11.4, 9.0, 6.3 cm), ...

  4. The environmental impact of informal and home productive arrangement in the jewelry and fashion jewelry chain on sanitary sewer system.

    Science.gov (United States)

    Salles, Fernanda Junqueira; Sato, Ana Paula Sayuri; Luz, Maciel Santos; Fávaro, Déborah Inês Teixeira; Ferreira, Francisco Jorge; da Silva Paganini, Wanderley; Olympio, Kelly Polido Kaneshiro

    2018-04-01

    The outsourcing informal home practices adopted in jewelry and fashion jewelry chain can cause toxic substance elimination in the effluents and raise a concern for its environmental impact. This study evaluates if this informal work alters the concentration of potentially toxic elements (PTEs: As, Cd, Cr total and Cr-VI, Cu, Hg, Ni, Pb, Sn, and Zn) in the sewage network. The sanitary sewage samples (n = 540) were collected in 15 manholes during two campaigns in three different areas of Limeira-SP, Brazil (industrial area, with informal work and without known industrial/informal activity). The sewage sludge (n = 12), raw (n = 12), and treated sewage (n = 12) were collected in two wastewater treatment plants (WWT: AS and TATU) operating with different treatment process. The PTE determination was performed by ICP-OES, direct mercury analysis, and UV-Vis spectroscopy. Cr-VI, Cu, Ni, and Zn were the only elements above the quantification limit. Four samples exceeded Cu or Zn values permitted to be discharged into sewage system; however, the concentration average was lower than that established by Brazilian legislation. A difference was found between values above and below the 75th percentile for campaign and total organic carbon values (p < 0.015). The AS-treated sewage presented low concentrations of Cu (p < 0.05), Zn (p = 0.02), and Ni (p = 0.01) compared to treated sewage from TATU. In the sludge samples, the Cu means exceeded the limits of the Brazilian legislation (1500 mg kg -1 ) and the Zn results were very close to the limits (2800 mg kg -1 ). The heterogeneity of the results can indicate the sporadic nature of the PTE's sanitary disposal. PTEs used in jewelry and fashion jewelry chain may precipitate on the sludge, where presented high concentrations of Cu and Zn which require controlled destination.

  5. Rocky Mountain Arsenal, Sanitary Sewer Interim Response Action, Construction Documents for New Sanitary Sewer Construction. Volume 2

    Science.gov (United States)

    1990-05-01

    prior to entry. When required by the Contracting Officer. the Contractor shall obtain andsubmit fingerprints of all persons employed or to be employed on...the mixture to the truck beds. Each load of mixture shall be covered with canvas , or other suitable material, of ample size to protect the mixture

  6. Impervious surfaces and sewer pipe effects on stormwater runoff temperature

    Science.gov (United States)

    Sabouri, F.; Gharabaghi, B.; Mahboubi, A. A.; McBean, E. A.

    2013-10-01

    The warming effect of the impervious surfaces in urban catchment areas and the cooling effect of underground storm sewer pipes on stormwater runoff temperature are assessed. Four urban residential catchment areas in the Cities of Guelph and Kitchener, Ontario, Canada were evaluated using a combination of runoff monitoring and modelling. The stormwater level and water temperature were monitored at 10 min interval at the inlet of the stormwater management ponds for three summers 2009, 2010 and 2011. The warming effect of the ponds is also studied, however discussed in detail in a separate paper. An artificial neural network (ANN) model for stormwater temperature was trained and validated using monitoring data. Stormwater runoff temperature was most sensitive to event mean temperature of the rainfall (EMTR) with a normalized sensitivity coefficient (Sn) of 1.257. Subsequent levels of sensitivity corresponded to the longest sewer pipe length (LPL), maximum rainfall intensity (MI), percent impervious cover (IMP), rainfall depth (R), initial asphalt temperature (AspT), pipe network density (PND), and rainfall duration (D), respectively. Percent impervious cover of the catchment area (IMP) was the key parameter that represented the warming effect of the paved surfaces; sensitivity analysis showed IMP increase from 20% to 50% resulted in runoff temperature increase by 3 °C. The longest storm sewer pipe length (LPL) and the storm sewer pipe network density (PND) are the two key parameters that control the cooling effect of the underground sewer system; sensitivity analysis showed LPL increase from 345 to 966 m, resulted in runoff temperature drop by 2.5 °C.

  7. Sanitary landfill in situ bioremediation optimization test. Final report

    International Nuclear Information System (INIS)

    1996-01-01

    This work was performed as part of a corrective action plan for the Savannah River Site Sanitary Landfill. This work was performed for the Westinghouse Savannah River Company Environmental Restoration Department as part of final implementation of a groundwater remediation system for the SRS Sanitary Landfill. Primary regulatory surveillance was provided by the South Carolina Department of Health and Environmental Control and the US Environmental Protection Agency (Region IV). The characterization, monitoring and remediation systems in the program generally consisted of a combination of innovative and baseline methods to allow comparison and evaluation. The results of these studies will be used to provide input for the full-scale groundwater remediation system for the SRS Sanitary Landfill. This report summarizes the performance of the Sanitary Landfill In Situ Optimization Test data, an evaluation of applicability, conclusions, recommendations, and related information for implementation of this remediation technology at the SRS Sanitary Landfill

  8. 2002 NPDES CSO Report to Congress

    Science.gov (United States)

    This report, delivered to Congress on January 29, 2002, identifies progress made in implementing and enforcing combined sewer overflow (CSO) controls prior to, and because of, the 1994 CSO control policy.

  9. Implication of climate change on urban drainage systems of Chicago and Mainstream and DesPlaines (MS/DP) Tunnel and Reservoir Plan (TARP)

    Science.gov (United States)

    Luo, H.; Schmidt, A.; Garcia, M. H.; Oberg, N.

    2016-12-01

    The impact of changing climate patterns and rainfall extremes on sewer system and river basin has been brought to attention to the researchers worldwide. In 1972, the Metropolitan Water Reclamation District of Greater Chicago (MWRDGC) adopted the Tunnel and Reservoir Plan (TARP) to address combined sewer overflow (CSO) pollution and flooding problems in the Chicago land area. The hydrosystem laboratory in University of Illinois at Urbana-Champaign developed a series of numerical models accordingly to analyze the complex hydraulic behavior of the as-built TARP system. Due to the interconnected nature of City of Chicago sewer network and MS/DP TARP system, a tightly coupled hydrological and hydraulic model MetroFlow was developed to facilitate such analysis by integrating previous developed models. This study utilized MetroFlow to predict the hydrologic/hydraulic response of the system for a set of pre-determined design and historical storm events. Accordingly, combined sewer overflows (CSO) of Chicago combined sewer system and MS/DP TARP system were evaluated under current and future weather scenarios. The total CSOs from TARP system can be considered as urban point pollution source to the surrounding receiving bodies, hence the potential impact of climate change on CSO fluxes is essential reference to wastewater infrastructure design and operations of the hydraulic regulating structures under storm events to mitigate predicted risks.

  10. Currents and Mixing in the San Lorenzo Overflow, Northern Gulf of California

    Science.gov (United States)

    Rosas-Villegas, Froylán.; López, Manuel; Candela, Julio

    2018-02-01

    The main properties of the San Lorenzo (SL) overflow are studied, using data from two nonsimultaneous ADCP moorings (located at the sill, and 5 km downstream), as well as CTD and LADCP profiles. Strong tidal currents at the sill modulate the overflow, which is not shut down during the neaps. At the downstream site, the largest flood currents are associated with colder water advected from the sill, flowing downslope, and creating an asymmetry in the semidiurnal tidal cycle. The overflow introduces a significant fortnightly harmonic at the downstream site, and delays the M2 tidal currents for more than an hour with respect to the currents at the sill. The overflow mixes with the overlying water by entrainment during its supercritical stage, reaching near-bottom velocities as high as 1.5 ms-1 and an estimated mean transport of 0.11 Sv; almost twice that estimated at the sill for the same period of the year. Estimated Froude numbers during spring tides suggest the development of an internal hydraulic jump. After relaxation of the maximum downstream currents, high-frequency temperature fluctuations, likely linked to upstream traveling waves, are consistently observed. Direct estimations of the turbulent dissipation rates were used to compute diapycnal diffusivity (Kρ) profiles. Mean estimates of Kρ, as high as 5.5 × 10-2 m2s-1, show that shear at the interface is the most significant source of cross-isopycnal mixing along the SL overflow during ebb tides.

  11. Modelling Illicit Drug Fate in Sewers for Wastewater-Based Epidemiology

    DEFF Research Database (Denmark)

    Ramin, Pedram

    was found during festival period as compared to normal weekdays. Wastewater-based epidemiology is a truly interdisciplinary approach in which engineering tools, including models developed and tested in this thesis, can be beneficial for the accurate estimation of drug consumption in urban areas........ Sewer systems can be considered as biological reactors, in which the concentration of organic chemicals present in wastewater can be impacted by in-sewer processes during hydraulic residence time. Illicit drug biomarkers, as trace organic chemicals in the range of nanograms to micrograms per liter...... on sorption and transformation of drug biomarkers in raw wastewater and sewer biofilms; and (ii) developing modelling tools – by combining and extending existing modelling frameworks – to predict such processes. To achieve this goal, a substantial part of this thesis was dedicated to the experimental...

  12. First district sanitary doctor of Katerynoslav

    OpenAIRE

    M.P. Chaban; Z.I. Shevtsova; V.V. Gaponov

    2017-01-01

    The life and professional activity of Vasyl Tymofiiovych Skrylnikov — a famous doctor-hygienist, scientist, and public figure have been represented. V.T. Skrylnikov contributed to the development of sanitary-prophylaxis direction in zemstvo medicine in Katerynoslav province in the second half of the 19th century; he was the first district sanitary doctor in Katerynoslav. The scientist actively studied medical features of natural agents, namely Tymofiivska clay. He successfully worked at Slovi...

  13. Resistance to anticoagulants in rats (Rattus norvegicus) in sewers in an urban area

    DEFF Research Database (Denmark)

    Lodal, Jens

    2007-01-01

    primarily tested for possible resistance to coumatetralyl, bromadiolone and difenacoum by Blood Clotting Response tests. Feeding test was used in tests for resistance to difethialone. A total of 24 rats trapped in sewers at 15 locations were tested. Resistance to bromadiolone was found among rats from all......Control of rats in sewers is, though of varying intensity, common practice in a majority of Danish municipalities and bromadiolone is the most preferred active ingredient. The results of sewer rat control is very difficult to register and very little is known about resistance among sewer rats...

  14. A statistical approach to guide the management of the anterior part of the sewer system

    NARCIS (Netherlands)

    Post, J.A.B.

    2016-01-01

    The anterior part of the sewer system consists of a system of gully pots and lateral (house) connections that drain to main sewers. The total length of lateral house connections can be similar to the total length of the sewers they drain to. In addition, there are 7 million gully pots with

  15. [Prophylactic requirements for sanitary and epidemiological surveillance in dentistry].

    Science.gov (United States)

    Kaplan, B M; Maksimenko, L V; Fedotova, N N; Gololobova, T V; Konovalov, O E

    2009-01-01

    The paper outlines the requirements for sanitary-and-epidemiological surveillance to prevent dental diseases. The investigations pose tasks to medical prevention centers to solve the problems in tooth prophylaxis, such as organizational-and-methodological, sanitary-and-educational, health-improving, and others. The sanitary-and-hygienic requirements for therapeutic-and-prophylactic dental facilities are defined. A procedure for keeping a management protocol for the prevention of tooth diseases is described.

  16. 10 CFR 20.2003 - Disposal by release into sanitary sewerage.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Disposal by release into sanitary sewerage. 20.2003... Disposal § 20.2003 Disposal by release into sanitary sewerage. (a) A licensee may discharge licensed material into sanitary sewerage if each of the following conditions is satisfied: (1) The material is...

  17. Hydrocarbon pollution fixed to combined sewer sediment: a case study in Paris.

    Science.gov (United States)

    Rocher, Vincent; Garnaud, Stéphane; Moilleron, Régis; Chebbo, Ghassan

    2004-02-01

    Over a period of two years (2000-2001), sediment samples were extracted from 40 silt traps (STs) spread through the combined sewer system of Paris. All sediment samples were analysed for physico-chemical parameters (pH, organic matter content, grain size distribution), with total hydrocarbons (THs) and 16 polycyclic aromatic hydrocarbons (PAHs) selected from the priority list of the US-EPA. The two main objectives of the study were (1) to determine the hydrocarbon contamination levels in the sediments of the Paris combined sewer system and (2) to investigate the PAH fingerprints in order to assess their spatial variability and to elucidate the PAH origins. The results show that there is some important inter-site and intra-site variations in hydrocarbon contents. Despite this variability, TH and PAH contamination levels (50th percentile) in the Parisian sewer sediment are estimated at 530 and 18 microg g(-1), respectively. The investigation of the aromatic compound distributions in all of the 40 STs has underlined that there is, at the Paris sewer system scale, a homogeneous PAH background pollution. Moreover, the study of the PAH fingerprints, using specific ratios, suggests the predominance of a pyrolytic origin for those PAHs fixed to the sewer sediment.

  18. 33 CFR 238.4 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... flood behavior typified by temporary conditions of inundation of normally dry land from the overflow of rivers and streams or from abnormally high coastal waters due to sever storms. (c) Storm sewer systems...

  19. Ventilation in Sewers Quantified by Measurements of CO2

    DEFF Research Database (Denmark)

    Fuglsang, Emil Dietz; Vollertsen, Jes; Nielsen, Asbjørn Haaning

    2012-01-01

    Understanding and quantifying ventilation in sewer systems is a prerequisite to predict transport of odorous and corrosive gasses within the system as well as their interaction with the urban atmosphere. This paper studies ventilation in sewer systems quantified by measurements of the natural...... occurring compound CO2. Most often Danish wastewater is supersaturated with CO2 and hence a potential for stripping is present. A novel model was built based on the kinetics behind the stripping process. It was applied to simulate ventilation rates from field measurements of wastewater temperature, p...

  20. 30 CFR 71.501 - Sanitary toilet facilities; maintenance.

    Science.gov (United States)

    2010-07-01

    ... Section 71.501 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sanitary Toilet Facilities at Surface Worksites of Surface Coal Mines § 71.501 Sanitary...

  1. Controlled overflowing of data-intensive jobs from oversubscribed sites

    Science.gov (United States)

    Sfiligoi, I.; Wuerthwein, F.; Bockelman, B.; Bradley, D. C.; Tadel, M.; Bloom, K.; Letts, J.; Mrak Tadel, A.

    2012-12-01

    The CMS analysis computing model was always relying on jobs running near the data, with data allocation between CMS compute centers organized at management level, based on expected needs of the CMS community. While this model provided high CPU utilization during job run times, there were times when a large fraction of CPUs at certain sites were sitting idle due to lack of demand, all while Terabytes of data were never accessed. To improve the utilization of both CPU and disks, CMS is moving toward controlled overflowing of jobs from sites that have data but are oversubscribed to others with spare CPU and network capacity, with those jobs accessing the data through real time Xrootd streaming over WAN. The major limiting factor for remote data access is the ability of the source storage system to serve such data, so the number of jobs accessing it must be carefully controlled. The CMS approach to this is to implement the overflowing by means of glideinWMS, a Condor based pilot system, and by providing the WMS with the known storage limits and let it schedule jobs within those limits. This paper presents the detailed architecture of the overflow-enabled glideinWMS system, together with operational experience of the past 6 months.

  2. Controlled overflowing of data-intensive jobs from oversubscribed sites

    International Nuclear Information System (INIS)

    Sfiligoi, I; Wuerthwein, F; Tadel, M; Letts, J; Mrak Tadel, A; Bockelman, B; Bloom, K; Bradley, D C

    2012-01-01

    The CMS analysis computing model was always relying on jobs running near the data, with data allocation between CMS compute centers organized at management level, based on expected needs of the CMS community. While this model provided high CPU utilization during job run times, there were times when a large fraction of CPUs at certain sites were sitting idle due to lack of demand, all while Terabytes of data were never accessed. To improve the utilization of both CPU and disks, CMS is moving toward controlled overflowing of jobs from sites that have data but are oversubscribed to others with spare CPU and network capacity, with those jobs accessing the data through real time Xrootd streaming over WAN. The major limiting factor for remote data access is the ability of the source storage system to serve such data, so the number of jobs accessing it must be carefully controlled. The CMS approach to this is to implement the overflowing by means of glideinWMS, a Condor based pilot system, and by providing the WMS with the known storage limits and let it schedule jobs within those limits. This paper presents the detailed architecture of the overflow-enabled glideinWMS system, together with operational experience of the past 6 months.

  3. [To the 90th anniversary of State Sanitary Epidemiologic Service Formation in Russian Federation].

    Science.gov (United States)

    Beliaev, E N; Podunova, L G

    2012-01-01

    State Educational Institution of Higher Professional Training of the Ministry of Health Care and Social Development Foundation of Russian Sanitary Epidemiologic Service dates back to September, 15, 1922, when a Decree on Sanitary Institutions of the Republic was signed. Afterwards the institutions of Sanitary Epidemiologic Service were improved: foundation of State Sanitary Inspectorate (1933-1951), approval of new concept of the Service and intensification of State Sanitary Inspectorate (1951-1991), foundation of State Sanitary Epidemiologic Service, centralization of management and financing of the Service, formation of Sanitary Epidemiologic Legislation (1991-2004), further restructurization of Sanitary Epidemiologic Service in accordance with administrative changes in Russia (2004 until now).

  4. Water Hammer in Pumped Sewer Mains

    DEFF Research Database (Denmark)

    Larsen, Torben

    This publication is intended for engineers seeking an introduction to the problem of water hammer in pumped pressure mains. This is a subject of increasing interest because of the development of larger and more integrated sewer systems. Consideration of water hammer is essential for structural...

  5. Implementation of Premixed Equilibrium Chemistry Capability in OVERFLOW

    Science.gov (United States)

    Olsen, Mike E.; Liu, Yen; Vinokur, M.; Olsen, Tom

    2004-01-01

    An implementation of premixed equilibrium chemistry has been completed for the OVERFLOW code, a chimera capable, complex geometry flow code widely used to predict transonic flowfields. The implementation builds on the computational efficiency and geometric generality of the solver.

  6. First district sanitary doctor of Katerynoslav

    Directory of Open Access Journals (Sweden)

    M.P. Chaban

    2017-02-01

    Full Text Available The life and professional activity of Vasyl Tymofiiovych Skrylnikov — a famous doctor-hygienist, scientist, and public figure have been represented. V.T. Skrylnikov contributed to the development of sanitary-prophylaxis direction in zemstvo medicine in Katerynoslav province in the second half of the 19th century; he was the first district sanitary doctor in Katerynoslav. The scientist actively studied medical features of natural agents, namely Tymofiivska clay. He successfully worked at Sloviansk resort, was the editor of a local newspaper. V.T. Skrylnikov is an author of many works on balneotherapy.

  7. Degradability of creatinine under sewer conditions affects its potential to be used as biomarker in sewage epidemiology.

    Science.gov (United States)

    Thai, Phong K; O'Brien, Jake; Jiang, Guangming; Gernjak, Wolfgang; Yuan, Zhiguo; Eaglesham, Geoff; Mueller, Jochen F

    2014-05-15

    Creatinine was proposed to be used as a population normalising factor in sewage epidemiology but its stability in the sewer system has not been assessed. This study thus aimed to evaluate the fate of creatinine under different sewer conditions using laboratory sewer reactors. The results showed that while creatinine was stable in wastewater only, it degraded quickly in reactors with the presence of sewer biofilms. The degradation followed first order kinetics with significantly higher rate in rising main condition than in gravity sewer condition. Additionally, daily loads of creatinine were determined in wastewater samples collected on Census day from 10 wastewater treatment plants around Australia. The measured loads of creatinine from those samples were much lower than expected and did not correlate with the populations across the sampled treatment plants. The results suggested that creatinine may not be a suitable biomarker for population normalisation purpose in sewage epidemiology, especially in sewer catchment with high percentage of rising mains. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Problems of sanitary-hygienic arrangements in case of emergency situations

    International Nuclear Information System (INIS)

    Avetisov, G.M.; Borisov, B.K.; Volkov, N.N.; Grachev, M.I.; Korostin, A.S.; Prostakishin, G.P.

    1995-01-01

    The planning and carrying out sanitary-hygienic arrangements in emergency situation are based on scientific-research, organizing-methodical and practical trends of activities including: the necessity of taking into consideration the risk of sanitary-hygienic complications as a result of emergency situation; elaboration of criteria and classification of hazards potential danger of industrial plants and territories; the establishment of system of providing sanitary-hygienic measures in emergency situation; working out prophylactic measures for prevention, localization and liquidation of sanitary-hygienic after-effects of emergency situation; development of the system of control and express-analysis of hazardous factors; elaboration of rating-methodical base and arrangements aimed at protection of health and life of people. 5 refs

  9. Satellite Sanitary Systems in Kampala, Uganda

    NARCIS (Netherlands)

    Letema, S.C.; Vliet, van B.J.M.; Lier, van J.B.

    2012-01-01

    Satellite sewage collection and treatment systems have been independently developed and managed in East African cities outside the centrally planned and sewered areas. A satellite approach is a promising provisioning option parallel to public sewerage for middle- and high-income residential areas,

  10. Satellite Sanitary Systems in Kampala, Uganda

    NARCIS (Netherlands)

    Letema, S.; Van Vliet, B.; Van Lier, J.B.

    2011-01-01

    Satellite sewage collection and treatment systems have been independently developed and managed in East African cities outside the centrally planned and sewered areas. A satellite approach is a promising provisioning option parallel to public sewerage for middle- and high-income residential areas,

  11. Radar Based Flow and Water Level Forecasting in Sewer Systems:a danisk case study

    OpenAIRE

    Thorndahl, Søren; Rasmussen, Michael R.; Grum, M.; Neve, S. L.

    2009-01-01

    This paper describes the first radar based forecast of flow and/or water level in sewer systems in Denmark. The rainfall is successfully forecasted with a lead time of 1-2 hours, and flow/levels are forecasted an additional ½-1½ hours using models describing the behaviour of the sewer system. Both radar data and flow/water level model are continuously updated using online rain gauges and online in-sewer measurements, in order to make the best possible predictions. The project show very promis...

  12. Agile Design of Sewer System Control

    NARCIS (Netherlands)

    Van Nooijen, R.P.; Kolechkina, A.G.; Van Leeuwen, P.E.R.M.; Van Velzen, E.

    2011-01-01

    We describe the first part of an attempt to include stakeholder participation in the design of a central automatic controller for a sewer system in a small pilot project (five subcatchments) and present lessons learned so far. The pilot is part of a project aimed at the improvement of water quality

  13. Artificial radionuclide tracer supply to the Denmark Strait overflow between 1972 and 1981

    Science.gov (United States)

    Livingston, Hugh D.; Swift, James H.; Ostlund, H. Gote

    1985-01-01

    Measurements of the concentrations of the artificial radionuclides 3H, 137Cs, and 90Sr in the northern Irminger Sea in 1972 and 1981 are reported. In both years, tracer measurements from this area included data from samples of the dense overflow water from the north through Denmark Strait. All three tracers were strongly correlated inversely with salinity in the dense outflows—the tracer maxima being related directly to the salinity minimum. When the tracer characteristics in the outflows in 1972 and 1981 were compared, concentrations of all in 1981 were observed to be about double the 1972 values. The individual tracer concentrations—on a decay-corrected, density-normalized basis—were higher in increasing order: 90Sr (+93%) seas of advected European nuclear fuel reprocessing wastes. Both the tracer and hydrographic data are used to identify northern locations of intermediate water formation capable of supplying the observed dense overflow water characteristics. It is argued, from the time taken for the overflow water to reflect the new surface 137Cs source, that transport from the source to the overflow can be quite rapid (about 2 years).

  14. Functional evaluation of pollutant transformation in sediment from combined sewer system.

    Science.gov (United States)

    Shi, Xuan; Ngo, Huu Hao; Sang, Langtao; Jin, Pengkang; Wang, Xiaochang C; Wang, Guanghua

    2018-07-01

    In this study, a pilot combined sewer system was constructed to characterize the pollutant transformation in sewer sediment. The results showed that particulate contaminants deposited from sewage could be transformed into dissolved matter by distinct pollutant transformation pathways. Although the oxidation-reduction potential (ORP) was varied from -80 mV to -340 mV in different region of the sediment, the fermentation was the dominant process in all regions of the sediment, which induced hydrolysis and decomposition of particulate contaminants. As a result, the accumulation of dissolved organic matter and the variation of ORP values along the sediment depth led to the depth-dependent reproduction characteristics of methanogens and sulfate-reducing bacteria, which were existed in the middle and deep layer of the sediment respectively. However, the diversity of nitrifying and polyphosphate-accumulating bacteria was low in sewer sediment and those microbial communities showed a non-significant correlation with nitrogen and phosphorus contaminants, which indicated that the enrichment of nitrogen and phosphorus contaminants was mainly caused by physical deposition process. Thus, this study proposed a promising pathway to evaluate pollutant transformation and can help provide theoretical foundation for urban sewer improvement. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Sanitary effects of fossil fuels; Effets sanitaires des combustibles fossiles

    Energy Technology Data Exchange (ETDEWEB)

    Nifenecker, H. [Centre National de la Recherche Scientifique (IN2P3/CNRS), 38 - Grenoble (France)

    2006-07-01

    In this compilation are studied the sanitary effects of fossil fuels, behavioral and environmental sanitary risks. The risks in connection with the production, the transport and the distribution(casting) are also approached for the oil(petroleum), the gas and the coal. Accidents in the home are evoked. The risks due to the atmospheric pollution are seen through the components of the atmospheric pollution as well as the sanitary effects of this pollution. (N.C.)

  16. 75 FR 30004 - Notice of Intent To Prepare an Environmental Impact Statement for the Elliott Bay Seawall Project...

    Science.gov (United States)

    2010-05-28

    ... transportation infrastructure (including the Burlington Northern--Santa Fe Railway main line) and utilities that serve downtown Seattle (including water, electric, gas/petroleum, steam, communications, sanitary sewers...

  17. Critical review on the stability of illicit drugs in sewers and wastewater samples.

    Science.gov (United States)

    McCall, Ann-Kathrin; Bade, Richard; Kinyua, Juliet; Lai, Foon Yin; Thai, Phong K; Covaci, Adrian; Bijlsma, Lubertus; van Nuijs, Alexander L N; Ort, Christoph

    2016-01-01

    Wastewater-based epidemiology (WBE) applies advanced analytical methods to quantify drug residues in wastewater with the aim to estimate illicit drug use at the population level. Transformation processes during transport in sewers (chemical and biological reactors) and storage of wastewater samples before analysis are expected to change concentrations of different drugs to varying degrees. Ignoring transformation for drugs with low to medium stability will lead to an unknown degree of systematic under- or overestimation of drug use, which should be avoided. This review aims to summarize the current knowledge related to the stability of commonly investigated drugs and, furthermore, suggest a more effective approach to future experiments. From over 100 WBE studies, around 50 mentioned the importance of stability and 24 included tests in wastewater. Most focused on in-sample stability (i.e., sample preparation, preservation and storage) and some extrapolated to in-sewer stability (i.e., during transport in real sewers). While consistent results were reported for rather stable compounds (e.g., MDMA and methamphetamine), a varying range of stability under different or similar conditions was observed for other compounds (e.g., cocaine, amphetamine and morphine). Wastewater composition can vary considerably over time, and different conditions prevail in different sewer systems. In summary, this indicates that more systematic studies are needed to: i) cover the range of possible conditions in sewers and ii) compare results more objectively. To facilitate the latter, we propose a set of parameters that should be reported for in-sewer stability experiments. Finally, a best practice of sample collection, preservation, and preparation before analysis is suggested in order to minimize transformation during these steps. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Value of Information for Sewer Replacement Decisions

    NARCIS (Netherlands)

    Van Riel, W.A.P.; Langeveld, J.G.; Herder, P.M.; Clemens, F.H.L.R.

    2014-01-01

    Decision-making for sewer asset management is partially based on intuition and often lacks explicit argumentation, hampering decision transparency and reproducibility. It is unknown to what extent each information source is appreciated by decision makers. Further insight into this relative

  19. A Microbial Signature Approach to Identify Fecal Pollution in the Waters Off an Urbanized Coast of Lake Michigan

    Science.gov (United States)

    Newton, Ryan J.; Bootsma, Melinda J.; Morrison, Hilary G.; Sogin, Mitchell L.

    2014-01-01

    Urban coasts receive watershed drainage from ecosystems that include highly developed lands with sewer and stormwater infrastructure. In these complex ecosystems, coastal waters are often contaminated with fecal pollution, where multiple delivery mechanisms that often contain multiple fecal sources make it difficult to mitigate the pollution. Here, we exploit bacterial community sequencing of the V6 and V6V4 hypervariable regions of the bacterial 16S rRNA gene to identify bacterial distributions that signal the presence of sewer, fecal, and human fecal pollution. The sequences classified to three sewer infrastructure-associated bacterial genera, Acinetobacter, Arcobacter, and Trichococcus, and five fecal-associated bacterial families, Bacteroidaceae, Porphyromonadaceae, Clostridiaceae, Lachnospiraceae, and Ruminococcaceae, served as signatures of sewer and fecal contamination, respectively. The human fecal signature was determined with the Bayesian source estimation program SourceTracker, which we applied to a set of 40 sewage influent samples collected in Milwaukee, WI, USA to identify operational taxonomic units (≥97 % identity) that were most likely of human fecal origin. During periods of dry weather, the magnitudes of all three signatures were relatively low in Milwaukee's urban rivers and harbor and nearly zero in Lake Michigan. However, the relative contribution of the sewer and fecal signature frequently increased to >2 % of the measured surface water communities following sewer overflows. Also during combined sewer overflows, the ratio of the human fecal pollution signature to the fecal pollution signature in surface waters was generally close to that of sewage, but this ratio decreased dramatically during dry weather and rain events, suggesting that nonhuman fecal pollution was the dominant source during these weather-driven scenarios. The qPCR detection of two human fecal indicators, human Bacteroides and Lachno2, confirmed the urban fecal footprint in

  20. Hydrologic monitoring for Chicago’s Sustainable Streetscapes Program

    Science.gov (United States)

    Duncker, James J.; Morrow, William S.

    2016-04-05

    sanitary flow) and wet weather conditions (stormwater runoff in addition to the sanitary flow). Sanitary flow is the largest source of flow in the combined sewers during dry weather, and stormwater runoff and sanitary flow combine during wet weather. The sewer flow data allow engineers and scientists to calculate total runoff volume for selected storm events.Wells are located within the project corridor to record water levels and help determine the direction of movement of groundwater in response to rainfall and snowmelt. In urban settings with aging sewer systems, groundwater can seep into the sewers or combined sewage can seep from the sewers into the local groundwater system. The groundwater data are also important in evaluating the overall impacts of increased infiltration resulting from BMPs.Data from wells show the relative water levels of shallow groundwater, water levels in the combined sewer system, and nearby surface-water channels within the project corridor. In some aging urban sewer systems, the local combined sewer system lies below the water table and receives substantial amounts of groundwater inflow, which can significantly reduce the amount of additional water the sewer system can accept.The bioswale along the south side of West Cermak Road near South Throop Street functions to infiltrate stormwater runoff from the road. Stormwater on the road surface initially drains to the curb and then flows along the curb until it reaches a curb cut-out. Materials within the bioswale allow stormwater to infiltrate and reduce the load to the combined sewer.A common feature in urban areas are curbside catch basins that collect stormwater runoff from paved streets. Stormwater drains first to the curb and then flows along the curb to the catch basin. Lateral sewer pipe connects the catch basin to the combined sewer beneath the street. The use of permeable pavers along the curbs in the project study reach let stormwater infiltrate before it reaches the curb, thus reducing

  1. Increased formate overflow is a hallmark of oxidative cancer.

    Science.gov (United States)

    Meiser, Johannes; Schuster, Anne; Pietzke, Matthias; Vande Voorde, Johan; Athineos, Dimitris; Oizel, Kristell; Burgos-Barragan, Guillermo; Wit, Niek; Dhayade, Sandeep; Morton, Jennifer P; Dornier, Emmanuel; Sumpton, David; Mackay, Gillian M; Blyth, Karen; Patel, Ketan J; Niclou, Simone P; Vazquez, Alexei

    2018-04-10

    Formate overflow coupled to mitochondrial oxidative metabolism\\ has been observed in cancer cell lines, but whether that takes place in the tumor microenvironment is not known. Here we report the observation of serine catabolism to formate in normal murine tissues, with a relative rate correlating with serine levels and the tissue oxidative state. Yet, serine catabolism to formate is increased in the transformed tissue of in vivo models of intestinal adenomas and mammary carcinomas. The increased serine catabolism to formate is associated with increased serum formate levels. Finally, we show that inhibition of formate production by genetic interference reduces cancer cell invasion and this phenotype can be rescued by exogenous formate. We conclude that increased formate overflow is a hallmark of oxidative cancers and that high formate levels promote invasion via a yet unknown mechanism.

  2. MANUAL: REAL TIME CONTROL OF COMBINED SEWERS

    Science.gov (United States)

    Managers, engineers, and operators of combined urban sewer systems are faced with difficult problems related to the operation and maintenance of their facilities. In addition to the issues related to the operation and upkeep of the system, many sewerage agencies are facing increa...

  3. [Environmental effects of combined sewage detention tank in central Shanghai].

    Science.gov (United States)

    Cheng, Jiang; Lü, Yong-peng; Huang, Xiao-fang; Guo, Sheng

    2009-08-15

    Through measuring the processes of precipitation, discharge and pollutant concentration over 20 times from 2006 to 2008 in Chendulu combined sewerage system (CSS) along Suzhou Creek in central Shanghai, the environmental effects of Chendulu combined sewage detention tank (CSDT), the first running CSDT in China, were studied. The results show that CSDT could improve CSS discharge capacity effectively with promoted interception ratio from 3.87 to 6.90-9.92. The mean annual combined sewer overflow (CSO) reduction and reduction rate are 9.10 x 10(4) m3 and 9.00%, respectively, and those of sanitary waste discharged directly to Suzhou Creek in non-rain-weather are 8.37 x 10(4) m(3) and 100% , respectively. The mean annual pollutants decrease rate of COD, BOD5, SS, NH4+ -N and TP of CSO are 13.76%, 19.69%, 15.29%, 18.24% and 15.10%, respectively, and those CSO pollutants decrease 41.21 t, 12.37 t, 50.10 t, 2.12 t and 0.29 t annually, respectively. The CSDT also could decrease sanitary waste discharged to Suzhou Creek totally, and those decreased pollutants are 20.75 t, 4.87 t, 14.90 t, 4.49 t and 0.30 t annually, respectively. The analysis shows that the CSDT design standard, running models and rainfall characteristics are the important influencing factors to realize the environmental effects of CSDT.

  4. EPA RESEARCH IN URBAN STORMWATER POLLUTION CONTROL

    Science.gov (United States)

    This state-of-the-art on the Environmental Protection Agency' s research in urban stormwater and combined sewer overflow pollution control describes the major elements of the Urban Runoff Pollution Control Program. roblem definition, users assistance tools, management alternative...

  5. The sewer collection system, the first treatment step

    International Nuclear Information System (INIS)

    Rustia, B.M.; Dickerson, J.R.

    2002-01-01

    'Full text:' The Civil Engineering Research Foundation's (CERF) Environmental Technology Evaluation Center (EvTEC) conducted an evaluation of a microbial treatment additive that converts the entire sewer collection system into an efficient high-speed treatment step. The technology claims to reduce total suspended solids (TSS) by > 60% and carbonaceous biological oxygen demand (CBOD), simultaneously by > 30% before it reaches the treatment plant. The technology uses pump station wet wells as the network nodes to add the microbial treatment to the waste water collection system This process uses the natural retention time in the sewer coupled with the addition of an extremely concentrated mixture of select, symbiotic, facultative microbes, which degrade the waste en route to the treatment plant. These bacteria do not produce odorous compounds and they replace the sulfur-reducing-bacteria (SRB) in the biomass on the walls of the force mains and on the wet perimeter of the gravity sewer piping by 'competitive exclusion.' This microbial substitution is achieved by the high quantity of organisms injected into the collection system. This reduces the sulfides in the wastewater thereby reducing the odor, along with greatly reducing the corrosion elements, which attack the piping in a sewer collection system. The objective of EvTEC evaluation was to verify the performance and reliability of such a microbial additive to treat wastewater and reduce plant 'sludges,' or biosolids. Among other performance issues, the evaluation addressed the technology's ability to treat domestic wastewater flows over an extended time period (i.e., greater than 3 months, 6 months, 12 months..., etc.) and to see if the benefits are improved during particular times of year. The benefits to using the additive include reducing the biosolids produced at the treatment plant and increasing the treatment plant's efficiency and capacity. This in turn helped reduce operating costs without requiring a large

  6. Transformation of AgCl nanoparticles in a sewer system — A field study

    Energy Technology Data Exchange (ETDEWEB)

    Kaegi, Ralf, E-mail: ralf.kaegi@eawag.ch [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, 8600 Dübendorf (Switzerland); Voegelin, Andreas; Sinnet, Brian [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, 8600 Dübendorf (Switzerland); Zuleeg, Steffen [KUSTER + HAGER Group, Oberstrasse 222, 9014 St. Gallen (Switzerland); Siegrist, Hansruedi [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, 8600 Dübendorf (Switzerland); Burkhardt, Michael [HSR University of Applied Sciences, Institute of Environmental and Process Engineering (UMTEC), Oberseestrasse 10, 8640 Rapperswil (Switzerland)

    2015-12-01

    Silver nanoparticles (Ag-NP) are increasingly used in consumer products and their release during the use phase may negatively affect aquatic ecosystems. Research efforts, so far, have mainly addressed the application and use of metallic Ag(0)-NP. However, as shown by recent studies on the release of Ag from textiles, other forms of Ag, especially silver chloride (AgCl), are released in much larger quantities than metallic Ag(0). In this field study, we report the release of AgCl-NP from a point source (industrial laundry that applied AgCl-NP during a piloting phase over a period of several months to protect textiles from bacterial regrowth) to the public sewer system and investigate the transformation of Ag during its transport in the sewer system and in the municipal wastewater treatment plant (WWTP). During the study period, the laundry discharged ~ 85 g of Ag per day, which dominated the Ag loads in the sewer system from the respective catchment (72–95%) and the Ag in the digested WWTP sludge (67%). Combined results from electron microscopy and X-ray absorption spectroscopy revealed that the Ag discharged from the laundry to the sewer consisted of about one third AgCl and two thirds Ag{sub 2}S, both forms primarily occurring as nanoparticles with diameters < 100 nm. During the 800 m transport in the sewer channel to the nearby WWTP, corresponding to a travel time of ~ 30 min, the remaining AgCl was transformed into nanoparticulate Ag{sub 2}S. Ag{sub 2}S-NP also dominated the Ag speciation in the digested sludge. In line with results from earlier studies, the very low Ag concentrations measured in the effluent of the WWTP (< 0.5 μg L{sup −1}) confirmed the very high removal efficiency of Ag from the wastewater stream (> 95%). - Highlights: • First field study on the transformation of AgCl nanoparticles released from a point source into the municipal sewer system. • Transformation of AgCl-NP into Ag{sub 2}S already occurred during 30-min transport in the

  7. CONTAMINATION OF URBAN SURFACE WATER BY VEHICLE EMISSIONS

    Science.gov (United States)

    2017-10-01

    Combined sewer overflows (CSOs) are a water management issue for Onondaga County and the city of Syracuse, NY. To reduce them, the County is investing in green infrastructure (GI). GI technologies such as green roofs, rain gardens, and bioswales are ...

  8. Long-term impacts on sewers following food waste disposer installation in housing areas.

    Science.gov (United States)

    Mattsson, Jonathan; Hedström, Annelie; Viklander, Maria

    2014-01-01

    To increase biogas generation and decrease vehicle transportation of solid waste, the integration of food waste disposers (FWDs) into the wastewater system has been proposed. However, concerns have been raised about the long-term impact of the additional load of the FWDs on sewer systems. To examine the said impact, this study has used closed-circuit television inspection techniques to evaluate the status of 181 concrete pipes serving single family housing areas with a diameter of 225 mm, ranging from a 100% connection rate of households with an FWD to none. A minor study was also performed on a multi-family housing area, where mainly plastic pipes (200 mm) were used. The extent and distribution of deposits related to the ratio of FWDs, inclination and pipe sagging (backfalls) were ascertained by using linear regression and analysis of variance. The results showed that FWDs have had an impact on the level of deposits in the sewer, but this has, in turn, been of minor significance. With a high connection rate of FWDs upstream of a pipe, the extent of the total level of deposits, as well as finer sediments, was statistically determined to be greater. However, the majority of the deposits were observed to be small, which would suggest the impact of FWDs on sewer performance to be minor. As food waste not compatible with the FWD was seen in the sewers, educational campaigns could be beneficial to further lower the risks of sewer blocking.

  9. Application of Morphological Segmentation to Leaking Defect Detection in Sewer Pipelines

    Directory of Open Access Journals (Sweden)

    Tung-Ching Su

    2014-05-01

    Full Text Available As one of major underground pipelines, sewerage is an important infrastructure in any modern city. The most common problem occurring in sewerage is leaking, whose position and failure level is typically identified through closed circuit television (CCTV inspection in order to facilitate rehabilitation process. This paper proposes a novel method of computer vision, morphological segmentation based on edge detection (MSED, to assist inspectors in detecting pipeline defects in CCTV inspection images. In addition to MSED, other mathematical morphology-based image segmentation methods, including opening top-hat operation (OTHO and closing bottom-hat operation (CBHO, were also applied to the defect detection in vitrified clay sewer pipelines. The CCTV inspection images of the sewer system in the 9th district, Taichung City, Taiwan were selected as the experimental materials. The segmentation results demonstrate that MSED and OTHO are useful for the detection of cracks and open joints, respectively, which are the typical leakage defects found in sewer pipelines.

  10. High prevalence of Leptospira spp. in sewer rats (Rattus norvegicus)

    DEFF Research Database (Denmark)

    Krøjgaard, L H; Villumsen, S; Markussen, M D K

    2009-01-01

    Earlier studies on the ecology of leptospirosis in temperate regions focused mainly on free-ranging rats in rural areas. Here we report on the occurrence of Leptospira spp. in Rattus norvegicus living in sewers in a suburban area in Copenhagen, Denmark. In 2006-2007, about 30 rats were captured...... in sewers at each of six different locations. Rat kidneys were screened by PCR for pathogenic Leptospira spp. In one location no infected rats were found, whereas the prevalence in the remaining five locations ranged between 48% and 89%. Micro-agglutination tests showed that serogroup Pomona, Sejroe...

  11. Air Flows in Gravity Sewers - Determination of Wastewater Drag Coefficient

    DEFF Research Database (Denmark)

    Bentzen, Thomas Ruby; Østertoft, Kristian; Vollertsen, Jes

    2016-01-01

    Several experiments have been conducted in order to improve the understanding of the wastewater drag and the wall frictional force acting on the headspace air in gravity sewers. The aim of the study is to improve the data basis for a numerical model of natural sewer ventilation. The results...... of the study shows that by integrating the top/side wall shear stresses the log-law models for the air velocity distribution along the unwetted perimeter resulted in a good agreement with the friction forces calculated by use of the Colebrook-White formula for hydraulic smooth pipes. Secondly, the water...

  12. Research and development of intelligent controller for high-grade sanitary ware

    Science.gov (United States)

    Bao, Kongjun; Shen, Qingping

    2013-03-01

    With the social and economic development and people's living standards improve, more and more emphasis on modern society, people improve the quality of family life, the use of intelligent controller applications in high-grade sanitary ware physiotherapy students. Analysis of high-grade sanitary ware physiotherapy common functions pointed out in the production and use of the possible risks, proposed implementation of the system hardware and matching, given the system software implementation process. High-grade sanitary ware physiotherapy intelligent controller not only to achieve elegant and beautiful, simple, physical therapy, water power, deodorant, multi-function, intelligent control, to meet the consumers, the high-end sanitary ware market, strong demand, Accelerate the enterprise product Upgrade and improve the competitiveness of enterprises.

  13. Stormwater induced input of Pb, Cd, As, Zn and other toxic heavy metals into the sewer system of a region characterized by mining residues. Final report

    International Nuclear Information System (INIS)

    Cichos, C.; Muehle, K.

    1993-06-01

    An estimation of heavy metal transport within the river Freiberger Mulde as well as detailed knowledge about pollutant concentration in sewage sludges, in surface soil and in various mining residues give rise to assume that stormwater induced input especially of As, Pb, Cd and Zn into the sewer system of the town of Freiberg has a significant share of contribution to the high pollution of the river. It is the aim of the project to determine the heavy metal input quantitatively where beside the entire transport above all the main transport ways are to be investigated. In the first period of research reported about a movable monitoring station with rainfall gauge, flow rate meter and automatic sampler had to be supplied. First results of stormwater effects at the main intercepting sewer were discussed on the basis of dry-wether flow. For precipitation intensities of 0.5-1 mm/10 min with 4 to 5fold discharge rates at the maximum the measurements showed about 2 to 6fold dry-wether diurnal loads during a rain wether flow of only one hour. Thus, for the case of flood flow up to 100fold diurnal loads may be expected within an hour. The pollutant transport depends on the intensity of rain and on the duration of dry wether before the rain. Further studies above all apply to the main ways of transport but simultaneously to the entire loads to be measured before the storm sewage overflow. Data to be expected in this way may contribute to a long-term simulation of the sewerage as an important aid for planning storage basins. (orig.) [de

  14. 78 FR 9908 - Notice of Availability of the Draft Issuance of the Small Municipal Separate Storm Sewer System...

    Science.gov (United States)

    2013-02-12

    ... Issuance of the Small Municipal Separate Storm Sewer System NPDES General Permit--New Hampshire AGENCY...) general permit for discharges from small Municipal Separate Storm Sewer Systems (MS4s) to certain waters... requirements of the CWA. The regulations at 40 CFR 122.26(b)(16) define a small municipal separate storm sewer...

  15. The Effect of Technology Overflows on CO2 Emissions in Iran

    International Nuclear Information System (INIS)

    Vaseghi, E.; Jalaee Esfandabadi, A

    2016-01-01

    Although economic growth is one of the most important objectives of governments, higher economic growth is mainly associated with an increase in environmental pollution. The experience of developed countries and some developing countries shows that, with increasing economic growth, environmental pollution is first increased and, then, it is reduced due to the attention to the environment at the level of production per capita; this can be shown in the Kuznets environmental curve. The main objective of this study is to determine the level of per capita income which causes reduced emissions of pollution due to considering the environmental issues, as well as studying the impact of technology overflow index on the turning point of the curve. In this regard, using the models of the demand of capital-intermediate goods import, the technology overflow index was calculated and its effect on the Kuznets environmental curve theory during the period of 1966 to 2013 was reviewed. The results showed that the technology overflow variable not only had a positive and significant impact on carbon dioxide emissions, but it also made the Kuznets environmental curve's turning point possible at a higher per capita income.

  16. MK-801 protection against methamphetamine-induced striatal dopamine terminal injury is associated with attenuated dopamine overflow.

    Science.gov (United States)

    Weihmuller, F B; O'Dell, S J; Marshall, J F

    1992-06-01

    Repeated administrations of methamphetamine (m-AMPH) produce high extracellular levels of dopamine (DA) and subsequent striatal DA terminal damage. Pharmacological blockade of N-methyl-D-aspartate (NMDA) receptors has been shown previously to prevent m-AMPH-induced striatal DA terminal injury, but the mechanism for this protection is unclear. In the present study, in vivo microdialysis was used to determine the effects of blockade of NMDA receptors with the noncompetitive antagonist MK-801 on m-AMPH-induced striatal DA overflow. Four injections of MK-801 (0.5 mg/kg, ip) alone did not significantly change extracellular striatal DA concentrations from pretreatment values. Four treatments with m-AMPH (4.0 mg/kg, sc at 2-hr intervals) increased striatal DA overflow, and the overflow was particularly extensive following the fourth injection. This m-AMPH regimen produced a 40% reduction in striatal DA tissue content 1 week later. Treatment with MK-801 15 min before each of the four m-AMPH injections or prior to only the last two m-AMPH administrations attenuated the m-AMPH-induced increase in striatal DA overflow and protected completely against striatal DA depletions. Other MK-801 treatment regimens less effectively reduced the m-AMPH-induced striatal DA efflux and were ineffective in protecting against striatal DA depletions. Linear regression analysis indicated that cumulative DA overflow was strongly predictive (r = -.68) of striatal DA tissue levels measured one week later. These findings suggest that the extensive DA overflow seen during a neurotoxic regimen of m-AMPH is a crucial component of the subsequent neurotoxicity.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Heavy rainfall: An underestimated environmental risk for buildings?

    Directory of Open Access Journals (Sweden)

    Golz Sebastian

    2016-01-01

    Second, heavy rain may result in urban pluvial flooding due to sewer overflow that cause severe damage to buildings. A comprehensive study of the impacts and the consequences in Dresden (Germany, presented in the paper, revealed that the potential risks of flooding from sewers due to hydraulic overload can be estimated on building scale using the model approach IVART (Integrated Spatial Vulnerability and Risk Assessment Tool. Modelling results provide the basis to quantify the effectiveness and efficiency of flood resilience technologies.

  18. Quantification of groundwater infiltration and surface water inflows in urban sewer networks based on a multiple model approach.

    Science.gov (United States)

    Karpf, Christian; Krebs, Peter

    2011-05-01

    The management of sewer systems requires information about discharge and variability of typical wastewater sources in urban catchments. Especially the infiltration of groundwater and the inflow of surface water (I/I) are important for making decisions about the rehabilitation and operation of sewer networks. This paper presents a methodology to identify I/I and estimate its quantity. For each flow fraction in sewer networks, an individual model approach is formulated whose parameters are optimised by the method of least squares. This method was applied to estimate the contributions to the wastewater flow in the sewer system of the City of Dresden (Germany), where data availability is good. Absolute flows of I/I and their temporal variations are estimated. Further information on the characteristics of infiltration is gained by clustering and grouping sewer pipes according to the attributes construction year and groundwater influence and relating these resulting classes to infiltration behaviour. Further, it is shown that condition classes based on CCTV-data can be used to estimate the infiltration potential of sewer pipes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Modelling of flow and settling in storm water sedimentation tanks

    OpenAIRE

    Kluck, J.

    1994-01-01

    In the near future in the Netherlands many reservoirs will have to be built to abate the pollution of the surface water by overflowing storm water from combined sewer systems [Kluck, 1992-a]. These reservoirs, called storm water sedimentation tanks, reduce the pollution in two ways. The most important is by simply storing a part of the sewage (waste water and storm water) and thus reducing the quantity of overflowing water. The second is by providing flow conditions in which particles can set...

  20. Sanitary-epidemiological audit in russia and abroad: challenges and growth prospects (analytical review

    Directory of Open Access Journals (Sweden)

    I.V. May

    2016-12-01

    Full Text Available The shaping the system of control and surveillance activities in the Russian Federation, which affects the bodies of the sanitary-epidemiological surveillance, requires the development of new forms of cooperation between authorities and legal entities, individual entrepreneurs and population. Such a form may be represented by the sanitary and epidemiological audit as an independent objective assessment of reputable third parties. The audit is intended to check the compliance with the mandatory requirements of the economic entities, performing economic or other activities. The sanitary-epidemiological audit may be associated with a system of certification for compliance with sanitary requirements and may assume the documented confirmation of the compliance issued by the authorized persons. The sanitary-epidemiological audit and the compliance certification to mandatory sanitary requirements can make an alternative to the planned supervision activities on facilities attributed to the category of low and moderate risk of harm to human health. The Russian sanitary legislation does not recognize the sanitary-epidemiological audit as a form of conformity assessment. The analysis of the international experience shows that it is necessary to consolidate the general rules and regulations of the sanitary-epidemiological audit at the legislative level and to develop a set of sublegislative documents in order to implement these norms. The crucial is a creation of the national system capable to regulate the registration and functioning of the organization having a right to conduct the audit activities in the field of hygienic safety. It is reasonable to develop the regulation on the list-register of auditors and to create a special training system for the auditors, who possess the methodology for health risk assessment. The key aspect of the successful introduction of the audit is a granting of presences to the economic entities having compliance

  1. Ants avoid superinfections by performing risk-adjusted sanitary care.

    Science.gov (United States)

    Konrad, Matthias; Pull, Christopher D; Metzler, Sina; Seif, Katharina; Naderlinger, Elisabeth; Grasse, Anna V; Cremer, Sylvia

    2018-03-13

    Being cared for when sick is a benefit of sociality that can reduce disease and improve survival of group members. However, individuals providing care risk contracting infectious diseases themselves. If they contract a low pathogen dose, they may develop low-level infections that do not cause disease but still affect host immunity by either decreasing or increasing the host's vulnerability to subsequent infections. Caring for contagious individuals can thus significantly alter the future disease susceptibility of caregivers. Using ants and their fungal pathogens as a model system, we tested if the altered disease susceptibility of experienced caregivers, in turn, affects their expression of sanitary care behavior. We found that low-level infections contracted during sanitary care had protective or neutral effects on secondary exposure to the same (homologous) pathogen but consistently caused high mortality on superinfection with a different (heterologous) pathogen. In response to this risk, the ants selectively adjusted the expression of their sanitary care. Specifically, the ants performed less grooming and more antimicrobial disinfection when caring for nestmates contaminated with heterologous pathogens compared with homologous ones. By modulating the components of sanitary care in this way the ants acquired less infectious particles of the heterologous pathogens, resulting in reduced superinfection. The performance of risk-adjusted sanitary care reveals the remarkable capacity of ants to react to changes in their disease susceptibility, according to their own infection history and to flexibly adjust collective care to individual risk.

  2. Stochastic long term modelling of a drainage system with estimation of return period uncertainty

    DEFF Research Database (Denmark)

    Thorndahl, Søren

    2009-01-01

    Long term prediction of maximum water levels and combined sewer overflow (CSO) in drainage systems are associated with large uncertainties. Especially on rainfall inputs, parameters, and assessment of return periods. This paper proposes a Monte Carlo based methodology for stochastic prediction of...

  3. Uncertainty Assessment in Long Term Urban Drainage Modelling

    DEFF Research Database (Denmark)

    Thorndahl, Søren

    the probability of system failures (defined as either flooding or surcharge of manholes or combined sewer overflow); (2) an application of the Generalized Likelihood Uncertainty Estimation methodology in which an event based stochastic calibration is performed; and (3) long term Monte Carlo simulations...

  4. Valuing information for sewer replacement decisions.

    Science.gov (United States)

    van Riel, Wouter; Langeveld, Jeroen; Herder, Paulien; Clemens, François

    Decision-making for sewer asset management is partially based on intuition and often lacks explicit argumentation, hampering decision transparency and reproducibility. This is not to be preferred in light of public accountability and cost-effectiveness. It is unknown to what extent each decision criterion is appreciated by decision-makers. Further insight into this relative importance improves understanding of decision-making of sewer system managers. As such, a digital questionnaire (response ratio 43%), containing pairwise comparisons between 10 relevant information sources, was sent to all 407 municipalities in the Netherlands to analyse the relative importance and assess whether a shared frame of reasoning is present. Thurstone's law of comparative judgment was used for analysis, combined with several consistency tests. Results show that camera inspections were valued highest, while pipe age was considered least important. The respondents were pretty consistent per individual and also showed consistency as a group. This indicated a common framework of reasoning among the group. The feedback of the group showed, however, the respondents found it difficult to make general comparisons without having a context. This indicates decision-making in practice is more likely to be steered by other mechanisms than purely combining information sources.

  5. Wind forcing of salinity anomalies in the Denmark Strait overflow

    Directory of Open Access Journals (Sweden)

    S. Hall

    2011-11-01

    Full Text Available The overflow of dense water from the Nordic Seas to the North Atlantic through Denmark Strait is an important part of the global thermohaline circulation. The salinity of the overflow plume has been measured by an array of current meters across the continental slope off the coast of Angmagssalik, southeast Greenland since September 1998. During 2004 the salinity of the overflow plume changed dramatically; the entire width of the array (70 km freshened between January 2004 and July 2004, with a significant negative salinity anomaly of about 0.06 in May. The event in May represents a fresh anomaly of over 3 standard deviations from the mean since recording began in 1998. The OCCAM 1/12° Ocean General Circulation Model not only reproduces the 2004 freshening event (r=0.96, p<0.01, but also correlates well with salinity observations over a previous 6 year period (r=0.54, p<0.01, despite the inevitable limitations of a z-coordinate model in representing the mixing processes at and downstream of the Denmark Strait sill. Consequently the physical processes causing the 2004 anomaly and prior variability in salinity are investigated using the model output. Our results reject the hypotheses that the anomaly is caused by processes occurring between the overflow sill and the moorings, or by an increase in upstream net freshwater input. Instead, we show that the 2004 salinity anomaly is caused by an increase in volume flux of low salinity water, with a potential density greater than 27.60 kg m−3, flowing towards the Denmark Strait sill in the East Greenland Current. This is caused by an increase in southward wind stress upstream of the sill at around 75° N 20° W four and a half months earlier, and an associated strengthening of the East Greenland Current.

  6. Structure and forcing of the overflow at the Storfjorden sill and its connection to the Arctic coastal polynya in Storfjorden

    Directory of Open Access Journals (Sweden)

    F. Geyer

    2010-03-01

    Full Text Available Storfjorden (Svalbard is a sill-fjord with an active polynya and exemplifies the dense water formation process over the Arctic shelves. Here we report on our simulations of Storfjorden covering the freezing season of 1999–2000 using an eddy-permitting 3-D ocean circulation model with a fully coupled dynamic and thermodynamic sea-ice model. The model results in the polynya region and of the dense water plume flowing over the sill crest are compared to observations. The connections of the overflow at the sill to the dense water production at the polynya and to the local wind forcing are investigated. Both the overflow and the polynya dynamics are found to be sensitive to wind forcing. In response to freezing and brine rejection over the polynya, the buoyancy forcing initiates an abrupt positive density anomaly. While the ocean integrates the buoyancy forcing over several polynya events (about 25 days, the wind forcing dominates the overflow response at the sill at weather scale. In the model, the density excess is diluted in the basin and leads to a gradual build-up of dense water behind the sill. The overflow transport is typically inferred from observations using a single current profiler at the sill crest. Despite the significant variability of the plume width, we show that a constant overflow width of 15 km produces realistic estimates of the overflow volume transport. Another difficulty in monitoring the overflow is measuring the plume thickness in the absence of hydrographic profiles. Volume flux estimates assuming a constant plume width and the thickness inferred from velocity profiles explain 58% of the modelled overflow volume flux variance and agrees to within 10% when averaged over the overflow season.

  7. Receding horizon control of hybrid linear delayed systems: Application to sewer networks

    OpenAIRE

    Joseph-Duran, Bernat; Ocampo-Martinez, Carlos; Cembrano, Gabriela

    2013-01-01

    A control-oriented hybrid linear model for water transport in sewer networks is proposed as a suitable framework for the computation of real-time controllers for the minimization of flooding in presence of heavy-rain events. The model is based on individual network elements (sewers, gates, weirs and tanks) and does not rely on topological simplifications, thus providing a better description of the hydrological and hydraulic phenomena than in similar works. Using a generic form of a hybrid lin...

  8. Efficient Heuristics for Simulating Population Overflow in Parallel Networks

    NARCIS (Netherlands)

    Zaburnenko, T.S.; Nicola, V.F.

    2006-01-01

    In this paper we propose a state-dependent importance sampling heuristic to estimate the probability of population overflow in networks of parallel queues. This heuristic approximates the “optimal��? state-dependent change of measure without the need for costly optimization involved in other

  9. A methodological approach to the design of optimising control strategies for sewer systems

    DEFF Research Database (Denmark)

    Mollerup, Ane Loft; Mikkelsen, Peter Steen; Sin, Gürkan

    2016-01-01

    This study focuses on designing an optimisation based control for sewer system in a methodological way and linking itto a regulatory control. Optimisation based design is found to depend on proper choice of a model, formulation of objective function and tuning of optimisation parameters. Accordin......This study focuses on designing an optimisation based control for sewer system in a methodological way and linking itto a regulatory control. Optimisation based design is found to depend on proper choice of a model, formulation of objective function and tuning of optimisation parameters....... Accordingly, two novel optimisation configurations are developed, where the optimisation either acts on the actuators or acts on the regulatory control layer. These two optimisation designs are evaluated on a sub-catchment of the sewer system in Copenhagen, and found to perform better than the existing...

  10. Effect of Parameters of Isopipe on the Quality of Glass Sheet Produced from Overflow Fusion Process by Numerical Simulation

    Directory of Open Access Journals (Sweden)

    Hou Yansheng

    2017-01-01

    Full Text Available A numerical model for simulation of molten glass flow with semi-implicit method for pressure-linked equations (SIMPLE and Volume of fluid (VOF method during the overflow fusion process was carried out by using FLUENT software. The effect of the geometry parameters of the isopipe and flow rate of molten glass on the flow patterns during overflow was investigated. The results showed that the overflow trough depth only had an effect on the flow rate distribution of glass melt around the inlet point. The tilt angle at the top of the trough had a significant effect on flow rate distribution along the length of the trough, and the desired mass distribution was achieved at the tilt angle 4°∼6°. The flow rate had a large influence on the overflow of the molten glass, which had a directive significance to the overflow down draw sheet manufacturing process.

  11. The prevalence of Leptospira sp in sewer rats (Rattus norvegicus)

    DEFF Research Database (Denmark)

    Krøigaard, Louise; Villumsen, Steen; Markussen, Mette Drude

    Test). Preliminary results based on one fourth of the captured rats indicate, that the prevalence of pathogenic leptospira infected sewer rats are relatively high, as 28 out 48 rats were positive by PCR. This suggests that the sewer could be an environment representing high prevalence of leptospira...... among rats and thus an environment with high risk of transmission....

  12. Output-feedback control of combined sewer networks through receding horizon control with moving horizon estimation

    Science.gov (United States)

    Joseph-Duran, Bernat; Ocampo-Martinez, Carlos; Cembrano, Gabriela

    2015-10-01

    An output-feedback control strategy for pollution mitigation in combined sewer networks is presented. The proposed strategy provides means to apply model-based predictive control to large-scale sewer networks, in-spite of the lack of measurements at most of the network sewers. In previous works, the authors presented a hybrid linear control-oriented model for sewer networks together with the formulation of Optimal Control Problems (OCP) and State Estimation Problems (SEP). By iteratively solving these problems, preliminary Receding Horizon Control with Moving Horizon Estimation (RHC/MHE) results, based on flow measurements, were also obtained. In this work, the RHC/MHE algorithm has been extended to take into account both flow and water level measurements and the resulting control loop has been extensively simulated to assess the system performance according different measurement availability scenarios and rain events. All simulations have been carried out using a detailed physically based model of a real case-study network as virtual reality.

  13. Sewer Networks Optimization by Particle Swarm Optimization with Abilities of Fly-Back Mechanism and Harmony Memory

    Directory of Open Access Journals (Sweden)

    محسن نفیسی

    2014-10-01

    Full Text Available Lack of an efficient sewer network in urban areas threatens public health and may give rise to contagious diseases. Various optimization methods have been developed for use in designing sewers networks in response to a number of requirements such as the high costs of constructing sewer networks, financial limitations, the presence of both discrete and continuous decision variables, and the nonlinear time complexity of such design problems. In this study, the particle swarm optimization algorithm (PSO with the capability of “fly-back” mechanism equipped with the harmony search (HPSO is used for the optimization of sewers network designs. The objective function consists of minimizing the excavation and embedding costs of commercial pipes. The fly-back mechanism and the harmony memory method are used to prevent leaving out variables from the feasible space of the problem in an attempt to enhance model efficiency. Model constraints are satisfied at two levels, which leads to the desirable convergence of the PSO algorithm as compared to the conventional penalty methods in alternative evolutionary algorithms. In order to determine the admissible decision variables, the Manning equation is used as a hydraulic model. The performance of the proposed algorithm is shown by presenting two examples of sewer networks. Compared to the PSO algorithm used in sewer network optimization models, the proposed model exhibits a tangible improvement in cost reduction and a higher computational stability.

  14. Influence of pipe material and surfaces on sulfide related odor and corrosion in sewers.

    Science.gov (United States)

    Nielsen, Asbjørn Haaning; Vollertsen, Jes; Jensen, Henriette Stokbro; Wium-Andersen, Tove; Hvitved-Jacobsen, Thorkild

    2008-09-01

    Hydrogen sulfide oxidation on sewer pipe surfaces was investigated in a pilot scale experimental setup. The experiments were aimed at replicating conditions in a gravity sewer located immediately downstream of a force main where sulfide related concrete corrosion and odor is often observed. During the experiments, hydrogen sulfide gas was injected intermittently into the headspace of partially filled concrete and plastic (PVC and HDPE) sewer pipes in concentrations of approximately 1,000 ppm(v). Between each injection, the hydrogen sulfide concentration was monitored while it decreased because of adsorption and subsequent oxidation on the pipe surfaces. The experiments showed that the rate of hydrogen sulfide oxidation was approximately two orders of magnitude faster on the concrete pipe surfaces than on the plastic pipe surfaces. Removal of the layer of reaction (corrosion) products from the concrete pipes was found to reduce the rate of hydrogen sulfide oxidation significantly. However, the rate of sulfide oxidation was restored to its background level within 10-20 days. A similar treatment had no observable effect on hydrogen sulfide removal in the plastic pipe reactors. The experimental results were used to model hydrogen sulfide oxidation under field conditions. This showed that the gas-phase hydrogen sulfide concentration in concrete sewers would typically amount to a few percent of the equilibrium concentration calculated from Henry's law. In the plastic pipe sewers, significantly higher concentrations were predicted because of the slower adsorption and oxidation kinetics on such surfaces.

  15. A Stochastic model for two-station hydraulics exhibiting transient impact

    DEFF Research Database (Denmark)

    Jacobsen, Judith L.; Madsen, Henrik; Harremoës, Poul

    1997-01-01

    The objective of the paper is to interpret data on water level variation in a river affected by overflow from a sewer system during rain. The simplest possible, hydraulic description is combined with stochastic methods for data analysis and model parameter estimation. This combination...

  16. Artificial radionuclide tracer supply to the Denmark strait overflow between 1972 and 1981

    International Nuclear Information System (INIS)

    Livingston, H.D.; Swift, J.H.; Ostlund, H.G.

    1985-01-01

    Measurements of the concentrations of the artificial radionuclides 3 H, 137 Cs, and 90 Sr in the northern Irminger Sea in 1972 and 1981 are reported. In both years, tracer measurements from this area included data from samples of the dense overflow water from the north through Denmark Strait. All three tracers were strongly correlated inversely with salinity in the dense outflows-the tracer maxima being related directly to the salinity minimum. When the tracer characteristics in the outflows in 1972 and 1981 were compared, concentrations of all in 1981 were observed to be about double the 1972 values. The individual tracer concentrations-on a decay-corrected, density-normalized basis-were higher in increasing order: 90 Sr(+93%) 3 H(+115%) 137 Cs(+150%). The relatively greater increases for 3 H and 137 Cs were attributed to contributions of new sources of these tracers in northern surface waters: the 3 H source is argued to derive from atmospheric hydrological recycling, whereas the 137 Cs source is identified as the input to the Greenland and Iceland seas of advected European nuclear fuel reprocessing wastes. Both the tracer and hydrographic data are used to identify northern locations of intermediate water formation capable of supplying the observed dense overflow water characteristics. It is argued, from the time taken for the overflow water to reflect the new surface 137 Cs source, that transport from the source to the overflow can be quite rapid (about 2 years)

  17. Sanitary landfill groundwater monitoring report: First quarter 1997

    Energy Technology Data Exchange (ETDEWEB)

    Chase, J.A.

    1997-05-01

    This report contains analytical data for samples taken during first quarter 1997 from wells of the LFW series located at the Sanitary Landfill at the Savannah River Site (SRS). The data are submitted in reference to the Sanitary Landfill Operating permit (DWP-087A). The report presents monitoring results that equaled or exceeded the Safe Drinking Water Act final primary Drinking Water Standards (PDWS) or screening levels, established by the U.S. Environmental Protection Agency, the South Carolina final Primary Drinking Water Standard for lead, or the SRS flagging criteria. Wells LFW6R, LFW8R, LFW10A, LFW18, LFW21, and LFW23R were not sampled due to their proximity to the Sanitary Landfill Closure Cap activities. Wells LFW61D and LFW62D are Purge Water Containment Wells and contain mercury. These wells were not sampled since the purge water cannot be treated at the M-1 Air Stripper until the NPDES permit for the stripper is modified.

  18. Late Glacial and Holocene Flow Dynamics of the Denmark Strait Overflow Water

    Science.gov (United States)

    Williams, M.; Schmidt, D. N.; Andersen, M. B.; Barker, S.; McCave, I. N. N.

    2014-12-01

    The overflow of dense water from the Nordic Seas to the North Atlantic across the Greenland-Scotland Ridge forms a major component of the deep branch of the Atlantic Meridional Overturning Circulation and influences the climate system in Northwest Europe. Research has focused on deep convection of the Iceland Scotland Overflow Water (ISOW) and its links to climate variability in the North Atlantic. Our understanding of the history of the Denmark Strait Overflow Water (DSOW) is significantly less constrained and yet it accounts for half of the total overflow production today. We focus on the Eirik Drift south of Greenland in the vicinity of the DSOW. Down-core 230Thxs derived sediment focusing factors (Ψ) and measurements of the mean size of sortable silt reveal winnowed sediments during the Last Glacial Maximum and Heinrich 1 suggesting an influx of vigorous southern sourced waters and restricted DSOW production. Reduced overflow may be due to glacial isostatic processes which shoaled the Denmark Strait sill combined with a southward shift of deep convection sites in response to enhanced ice cover in the Nordic Seas. Intensification of the DSOW is evident between 9 and 13ka BP indicating initial deepening of the Denmark Strait sill and northward migration of the locus of deep water production. Ψ values for the Holocene suggest an active DSOW with a shift in the flow regime at 6.8 ka BP indicated by a reduction and subsequent stabilization of mean size sortable silt during the mid-late Holocene. This is corroborated by other studies showing a reorganization of the deep water after 7ka. An establishment of the Labrador Sea Water at intermediate depths altered the density structure of the deep western boundary current and weakened the ISOW. Changes in deep water circulation occur as North Atlantic climate entered Neoglacial cooling determined by Mg/Ca derived sea surface temperatures and abundances of the polar planktic foraminifera species N. pachyderma. They

  19. TECHNICAL AND ECONOMICAL COMPARISON OF OVERFLOW DAM VARIANTS AT THE GRODNO WATER-POWER STATION

    Directory of Open Access Journals (Sweden)

    G. G. Krouglov

    2005-01-01

    Full Text Available The paper considers various aspects pertaining to determination of main technical characteristics of water-development projects of water-power stations. Technical and economical characteristics of overflow dams at the Grodno water-power station are compared in the paper.The paper contains results of model investigations of two-tier overflow dam which is included in composition of the Grodno water-power station and presents methodology for calculation of pool integration behind two-tier dam which has been developed at the water-development and power engineering department. This methodology makes it possible to determine rate coefficient and compressed depth. In addition to this the paper gives technical and economical comparison of various designs of overflow dams at the Grodno water-power station, analyzes their cost and on the basis of this comparative analysis it is recommended to construct a two-pier dam. 

  20. Impacts and managerial implications for sewer systems due to recent changes to inputs in domestic wastewater - A review.

    Science.gov (United States)

    Mattsson, Jonathan; Hedström, Annelie; Ashley, Richard M; Viklander, Maria

    2015-09-15

    Ever since the advent of major sewer construction in the 1850s, the issue of increased solids deposition in sewers due to changes in domestic wastewater inputs has been frequently debated. Three recent changes considered here are the introduction of kitchen sink food waste disposers (FWDs); rising levels of inputs of fat, oil and grease (FOG); and the installation of low-flush toilets (LFTs). In this review these changes have been examined with regard to potential solids depositional impacts on sewer systems and the managerial implications. The review indicates that each of the changes has the potential to cause an increase in solids deposition in sewers and this is likely to be more pronounced for the upstream reaches of networks that serve fewer households than the downstream parts and for specific sewer features such as sags. The review has highlighted the importance of educational campaigns directed to the public to mitigate deposition as many of the observed problems have been linked to domestic behaviour in regard to FOGs, FWDs and toilet flushing. A standardized monitoring procedure of repeat sewer blockage locations can also be a means to identify depositional hot-spots. Interactions between the various changes in inputs in the studies reviewed here indicated an increased potential for blockage formation, but this would need to be further substantiated. As the precise nature of these changes in inputs have been found to be variable, depending on lifestyles and type of installation, the additional problems that may arise pose particular challenges to sewer operators and managers because of the difficulty in generalizing the nature of the changes, particularly where retrofitting projects in households are being considered. The three types of changes to inputs reviewed here highlight the need to consider whether or not more or less solid waste from households should be diverted into sewers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Hanford 200 area (sanitary) waste water system

    International Nuclear Information System (INIS)

    Danch, D.A.; Gay, A.E.

    1994-09-01

    The US Department of Energy (DOE) Hanford Site is located in southeastern Washington State. The Hanford Site is approximately 1,450 sq. km (560 sq. mi) of semiarid land set aside for activities of the DOE. The reactor fuel processing and waste management facilities are located in the 200 Areas. Over the last 50 years at Hanford dicard of hazardous and sanitary waste water has resulted in billions of liters of waste water discharged to the ground. As part of the TPA, discharges of hazardous waste water to the ground and waters of Washington State are to be eliminated in 1995. Currently sanitary waste water from the 200 Area Plateau is handled with on-site septic tank and subsurface disposal systems, many of which were constructed in the 1940s and most do not meet current standards. Features unique to the proposed new sanitary waste water handling systems include: (1) cost effective operation of the treatment system as evaporative lagoons with state-of-the-art liner systems, and (2) routing collection lines to avoid historic contamination zones. The paper focuses on the challenges met in planning and designing the collection system

  2. Climate impacts of parameterized Nordic Sea overflows

    Science.gov (United States)

    Danabasoglu, Gokhan; Large, William G.; Briegleb, Bruce P.

    2010-11-01

    A new overflow parameterization (OFP) of density-driven flows through ocean ridges via narrow, unresolved channels has been developed and implemented in the ocean component of the Community Climate System Model version 4. It represents exchanges from the Nordic Seas and the Antarctic shelves, associated entrainment, and subsequent injection of overflow product waters into the abyssal basins. We investigate the effects of the parameterized Denmark Strait (DS) and Faroe Bank Channel (FBC) overflows on the ocean circulation, showing their impacts on the Atlantic Meridional Overturning Circulation and the North Atlantic climate. The OFP is based on the Marginal Sea Boundary Condition scheme of Price and Yang (1998), but there are significant differences that are described in detail. Two uncoupled (ocean-only) and two fully coupled simulations are analyzed. Each pair consists of one case with the OFP and a control case without this parameterization. In both uncoupled and coupled experiments, the parameterized DS and FBC source volume transports are within the range of observed estimates. The entrainment volume transports remain lower than observational estimates, leading to lower than observed product volume transports. Due to low entrainment, the product and source water properties are too similar. The DS and FBC overflow temperature and salinity properties are in better agreement with observations in the uncoupled case than in the coupled simulation, likely reflecting surface flux differences. The most significant impact of the OFP is the improved North Atlantic Deep Water penetration depth, leading to a much better comparison with the observational data and significantly reducing the chronic, shallow penetration depth bias in level coordinate models. This improvement is due to the deeper penetration of the southward flowing Deep Western Boundary Current. In comparison with control experiments without the OFP, the abyssal ventilation rates increase in the North

  3. Sanitary Landfill Groundwater Monitoring Report, Second Quarter 1999

    Energy Technology Data Exchange (ETDEWEB)

    Chase, J.

    1999-07-29

    This report contains analytical data for samples taken during Second Quarter 1999 from wells of the LFW series located at the Sanitary Landfill at the Savannah River Site. The data are submitted in reference to the Sanitary Landfill Operating Permit. The report presents monitoring results that equaled or exceeded the Safe Drinking Water Act final Primary Drinking Water Standards or screening levels, established by the US Environmental Protection Agency, the South Carolina final Primary Drinking Water Standard for lead, or the SRS flagging criteria.

  4. Sanitary landfill groundwater monitoring report, Third Quarter 1999

    Energy Technology Data Exchange (ETDEWEB)

    Chase, J.

    1999-12-08

    This report contains analytical data for samples taken during Third Quarter 1999 from wells of the LFW series located at the Sanitary Landfill at the Savannah River Site. The data are submitted in reference to the Sanitary Landfill Operating Permit. The report presents monitoring results that equaled or exceeded the Safe Drinking Water Act final Primary Drinking Water Standards or screening levels, established by the U.S. Environmental Protection Agency, the South Carolina final Primary Drinking Water Standard for lead, or the SRS flagging criteria.

  5. Sanitary landfill groundwater monitoring report, Third Quarter 1999

    International Nuclear Information System (INIS)

    Chase, J.

    1999-01-01

    This report contains analytical data for samples taken during Third Quarter 1999 from wells of the LFW series located at the Sanitary Landfill at the Savannah River Site. The data are submitted in reference to the Sanitary Landfill Operating Permit. The report presents monitoring results that equaled or exceeded the Safe Drinking Water Act final Primary Drinking Water Standards or screening levels, established by the U.S. Environmental Protection Agency, the South Carolina final Primary Drinking Water Standard for lead, or the SRS flagging criteria

  6. Vapor Intrusion from Entrapped NAPL Sources and Groundwater Plumes: Process Understanding and Improved Modeling Tools for Pathway Assessment

    Science.gov (United States)

    2014-07-01

    into a building ....149 Figure 5.52: Effect of infiltration at 1 mm/hr for 24 hours on vapor signals in sandy clay loam scenario...shown above, there will also likely be large diameter sanitary sewers running the length of each street. Each house on the street will have a sewer...permeability, a discontinuous clay layer system, and a system with scattered obstacles (e.g. utilities). The layered systems indicated that the sequence of

  7. Environmental Assessment, Repair of the Dam at Non-Potable Reservoir #1, United States Air Force Academy, Colorado

    Science.gov (United States)

    2015-08-01

    expected and are not analyzed further in this EA. Utilities. The electrical, natural gas, water, and sanitary sewer requirements of the Proposed...therefore, no increase in utility usage or sanitary and solid waste generation would occur. Utility connections that run alongside the existing dam...for evaluation of the soils suitability for native revegetation. An acceptable topsoil shall have a loam, sandy loam, clay loam, or silt loam texture

  8. Environmental Assessment for the Power Plant Upgrade, Construct Fuel Farm, Cavalier Air Force Station, North Dakota

    Science.gov (United States)

    2013-06-01

    cooling water, fire water, domestic water, sanitary systems, con- trol room, and other requirements which would be utilized in place. Constructing a new...communica- tions requirements, sanitary sewer, and electrical connections back to the PAR building are expected to be routed through the new...Pembina Delta Aquifer is underlain by shale bedrock and by glacial till and thick deposits of lake clay and silt. Small aquifers within the

  9. Update on Kansas City Middle Blue River Green Infrastructure Pilot Project

    Science.gov (United States)

    In 2010, Kansas City, MO (KCMO) signed a consent degree with EPA on combined sewer overflows. The City decided to use adaptive management in order to extensively utilize green infrastructure (GI) in lieu of, and in addition to, gray structural controls. KCMO installed 130 GI sto...

  10. Update on Kansas City Middle Blue River Green Infrastructure Pilot Project - seminar

    Science.gov (United States)

    In 2010, Kansas City, MO (KCMO) signed a consent degree with EPA on combined sewer overflows. The City decided to use adaptive management in order to extensively utilize green infrastructure (GI) in lieu of, and in addition to, structural controls. KCMO installed 130 GI storm con...

  11. Effects of a 20 year rain event: a quantitative microbial risk assessment of a case of contaminated bathing water in Copenhagen, Denmark

    DEFF Research Database (Denmark)

    Andersen, Signe Tanja; Erichsen, A. C.; Mark, O.

    2013-01-01

    Quantitative microbial risk assessments (QMRAs) often lack data on water quality leading to great uncertainty in the QMRA because of the many assumptions. The quantity of waste water contamination was estimated and included in a QMRA on an extreme rain event leading to combined sewer overflow (CS...

  12. Sanitary landfill groundwater monitoring report. Third quarter 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    This report contains analytical data for samples taken during third quarter 1995 from wells of the LFW series located at the Sanitary Landfill at the Savannah River Site (SRS). The data are submitted in reference to the Sanitary Landfill Operating Permit (DWP-087A). The report presents monitoring results that equaled or exceeded the Safe Drinking Water Act final Primary Drinking Water Standards (PDWS) or screening levels, established by the U.S. Environmental Protection Agency, the South Carolina final Primary Drinking Water Standard for lead, or the SRS flagging criteria.

  13. Sanitary landfill groundwater monitoring report. Third quarter 1995

    International Nuclear Information System (INIS)

    1995-11-01

    This report contains analytical data for samples taken during third quarter 1995 from wells of the LFW series located at the Sanitary Landfill at the Savannah River Site (SRS). The data are submitted in reference to the Sanitary Landfill Operating Permit (DWP-087A). The report presents monitoring results that equaled or exceeded the Safe Drinking Water Act final Primary Drinking Water Standards (PDWS) or screening levels, established by the U.S. Environmental Protection Agency, the South Carolina final Primary Drinking Water Standard for lead, or the SRS flagging criteria

  14. Renovation of the Stockholm sewerage system

    International Nuclear Information System (INIS)

    Sandin, Paer

    1987-01-01

    Within a few years Stockholm will let all its treated wastewater into the Saltsjoen. The Saltsjoen is the inner part of the Stockholm Archipelago, which is one of the finest recreation areas in Sweden and where many Stockholmians spend a great deal of their leisure time. That is one reason why it is so important that all wastewater is treated before it reaches the recipient. A sewerage system in bad condition means that the risk of not allowed/unplanned overflows is increased. In order to prevent overflows we drafted 'Plan 83' which tells us how our sewerage system shall be constructed in the future and what measures has to be made in the system. Renovations of the existing pipes is one method to get a well functioning sewer system. Today we have made about 50 different objects at a total length of 6000 m. Why do we renovate sewers and why are we attempting to develop methods for pipe renovations?

  15. Numerical simulation of overflow at vertical weirs using a hybrid level set/VOF method

    Science.gov (United States)

    Lv, Xin; Zou, Qingping; Reeve, Dominic

    2011-10-01

    This paper presents the applications of a newly developed free surface flow model to the practical, while challenging overflow problems for weirs. Since the model takes advantage of the strengths of both the level set and volume of fluid methods and solves the Navier-Stokes equations on an unstructured mesh, it is capable of resolving the time evolution of very complex vortical motions, air entrainment and pressure variations due to violent deformations following overflow of the weir crest. In the present study, two different types of vertical weir, namely broad-crested and sharp-crested, are considered for validation purposes. The calculated overflow parameters such as pressure head distributions, velocity distributions, and water surface profiles are compared against experimental data as well as numerical results available in literature. A very good quantitative agreement has been obtained. The numerical model, thus, offers a good alternative to traditional experimental methods in the study of weir problems.

  16. Utility Bill Insert for Wastewater Services

    Science.gov (United States)

    Intended for use by wastewater and water supply utilities, one side of the utility bill insert has information for customers that discharge to sanitary sewer systems; the other side is for customers with septic systems.

  17. Urban runoff - Swedish experience

    International Nuclear Information System (INIS)

    Falk, Jan

    1987-01-01

    During the past 20 years hard effort has been devoted to the protection of rivers, lakes and the sea from pollution. This effort has mainly been focused on the obvious sources of pollution i.e. the concentrated outlet of sewage. Currently 75% of the urban population is served by advanced treatment plants. Not until recently attention was paid to sewerage. The official policy was that separate storm sewers was the only acceptable system and discharge permits generally required separation of existing combined sewers were to be abandoned there was little concern about overflows

  18. Long Term Estimates of Removal of Heavy Metals and PAH in Retention Basins

    DEFF Research Database (Denmark)

    Larsen, Torben; Neerup-Jensen, O.

    2004-01-01

    The paper describes a method for the long-term simulation of the discharge of pollutants to the environment from storm sewer overflows in combined sewer systems, which have a connected retention basins. This study covers heavy metals (Cd, Cu, Ni, Pb, Zn) and PAH. The method includes both...... the influence of the flow-dependant sedimentation and the variation of the settling velocity of the particles. The results show that including these effects lead to significant lower discharges of pollutants compared to conventional methods of estimation. As an example computations with a spectrum of basins...

  19. Research on Overflow Monitoring Mechanism Based on Downhole Microflow Detection

    Directory of Open Access Journals (Sweden)

    Liang Ge

    2014-01-01

    Full Text Available The flow rate variation of the drilling fluid and micro-overflow loss is difficult to analyze. The purpose to prevent the occurrence of kick, lost circulation, and other complex conditions is not easy to be achieved. Therefore, the microflow-induced annulus multiphase flow rate and annulus pressure field model were studied, and a downhole microflow measurement system has been developed. A differential pressure type flow measurement was used in the system, and real-time downhole information was obtained to achieve deep, narrow windows and other safety-density complex formation security. This paper introduced a new bottom-hole flow meter which can measure the annular flux while drilling and monitor overflow and circulation loss. The accuracy and reliability of the MPD (managed pressure drilling system can be improved obviously by applying the device; as a result, the safety of drilling is enhanced and the cost is reduced.

  20. Modeling the Hydrologic Effects of Large-Scale Green Infrastructure Projects with GIS

    Science.gov (United States)

    Bado, R. A.; Fekete, B. M.; Khanbilvardi, R.

    2015-12-01

    Impervious surfaces in urban areas generate excess runoff, which in turn causes flooding, combined sewer overflows, and degradation of adjacent surface waters. Municipal environmental protection agencies have shown a growing interest in mitigating these effects with 'green' infrastructure practices that partially restore the perviousness and water holding capacity of urban centers. Assessment of the performance of current and future green infrastructure projects is hindered by the lack of adequate hydrological modeling tools; conventional techniques fail to account for the complex flow pathways of urban environments, and detailed analyses are difficult to prepare for the very large domains in which green infrastructure projects are implemented. Currently, no standard toolset exists that can rapidly and conveniently predict runoff, consequent inundations, and sewer overflows at a city-wide scale. We demonstrate how streamlined modeling techniques can be used with open-source GIS software to efficiently model runoff in large urban catchments. Hydraulic parameters and flow paths through city blocks, roadways, and sewer drains are automatically generated from GIS layers, and ultimately urban flow simulations can be executed for a variety of rainfall conditions. With this methodology, users can understand the implications of large-scale land use changes and green/gray storm water retention systems on hydraulic loading, peak flow rates, and runoff volumes.

  1. Reconsidering Urban Sewer and Treatment Facilities in East Africa as Interplay of Flows, Networks and Spaces

    NARCIS (Netherlands)

    Letema, S.C.; Vliet, van B.J.M.; Lier, van J.B.

    2010-01-01

    Urbanization has brought about concentrations of people in densely populated settlements, resulting in the generation of waste water that needs to be disposed off in a hygienic way to avoid the outbreak of diseases. Decisions on what area to sewer, the nature of sewer schemes and treatment works to

  2. Prospective Science Teachers' Subject-Matter Knowledge about Overflow Container

    Science.gov (United States)

    Ültay, Eser

    2016-01-01

    The purpose of this study was to determine prospective science teachers' subject-matter knowledge (SMK) about overflow container. This study was carried out in the form of a case study in spring term of the academic year of 2013-2014 with seven sophomore prospective science teachers who were studying at Elementary Science Teaching Department in…

  3. Probabilistic modelling of overflow, surcharge and flooding in urban drainage using the first-order reliability method and parameterization of local rain series.

    Science.gov (United States)

    Thorndahl, S; Willems, P

    2008-01-01

    Failure of urban drainage systems may occur due to surcharge or flooding at specific manholes in the system, or due to overflows from combined sewer systems to receiving waters. To quantify the probability or return period of failure, standard approaches make use of the simulation of design storms or long historical rainfall series in a hydrodynamic model of the urban drainage system. In this paper, an alternative probabilistic method is investigated: the first-order reliability method (FORM). To apply this method, a long rainfall time series was divided in rainstorms (rain events), and each rainstorm conceptualized to a synthetic rainfall hyetograph by a Gaussian shape with the parameters rainstorm depth, duration and peak intensity. Probability distributions were calibrated for these three parameters and used on the basis of the failure probability estimation, together with a hydrodynamic simulation model to determine the failure conditions for each set of parameters. The method takes into account the uncertainties involved in the rainstorm parameterization. Comparison is made between the failure probability results of the FORM method, the standard method using long-term simulations and alternative methods based on random sampling (Monte Carlo direct sampling and importance sampling). It is concluded that without crucial influence on the modelling accuracy, the FORM is very applicable as an alternative to traditional long-term simulations of urban drainage systems.

  4. Detailed test plan on co-disposal of deminumum levels of LLRW and sanitary waste

    International Nuclear Information System (INIS)

    Chian, E.S.K.

    1984-01-01

    The major objectives of this investigation are: (1) to study the attenuation mechanisms for radionuclides (LLRW) in simulated sanitary landfills with and without leachate recycle; and (2) to determine the complexation potential of ligands (viz., sulfides, humic substances) present in the leachate during different stages of landfill stabilization. Since the major emphasis of this research is on containment and isolation of LLRW within a sanitary landfill the following key elements have been incorporated into the design of the simulated pilot-scale sanitary landfills: (1) containment of LLRW within the landfills by placing the municipal refuse and LLRW in polymeric membrane-lined cells (30-mil, HDA, Gundline liner, Gundle, TX) with a leachate collection system; (2) enhancement of stabilization by leachate recycle; and (3) recovery of the gas produced from the sanitary landfills. The proposed research program addresses the fate of LLRW in municipal sanitary landfills thereby, establishing a data base to predict radionuclide pathways in sanitary landfills and to aid in assessing the environmental impacts of codisposal of LLRW within sanitary landfills. The outcome of this study may also serve to alleviate the current concern of unnecessary filling of limited space in existing licensed shallow-land burial sites. 4 figures, 1 table

  5. New zero-input overflow stability proofs based on Lyapunov theory

    NARCIS (Netherlands)

    Werter, M.J.; Ritzerfeld, J.H.F.

    1989-01-01

    The authors demonstrate some proofs of zero-input overflow-oscillation suppression in recursive digital filters. The proofs are based on the second method of Lyapunov. For second-order digital filters with complex conjugated poles, the state describes a trajectory in the phase plane, spiraling

  6. Controlled overflowing of data-intensive jobs from oversubscribed sites

    CERN Document Server

    Sfiligoi, Igor; Bockelman, Brian Paul; Bradley, Daniel Charles; Tadel, Matevz; Bloom, Kenneth Arthur; Letts, James; Mrak Tadel, Alja

    2012-01-01

    The CMS analysis computing model was always relying on jobs running near the data, with data allocation between CMS compute centers organized at management level, based on expected needs of the CMS community. While this model provided high CPU utilization during job run times, there were times when a large fraction of CPUs at certain sites were sitting idle due to lack of demand, all while Terabytes of data were never accessed. To improve the utilization of both CPU and disks, CMS is moving toward controlled overflowing of jobs from sites that have data but are oversubscribed to others with spare CPU and network capacity, with those jobs accessing the data through real time Xrootd streaming over WAN. The major limiting factor for remote data access is the ability of the source storage system to serve such data, so the number of jobs accessing it must be carefully controlled. The CMS approach to this is to implement the overflowing by means of glideinWMS, a Condor based pilot system, and by providing the WMS w...

  7. Modelling of flow and settling in storm water sedimentation tanks

    NARCIS (Netherlands)

    Kluck, J.

    1994-01-01

    In the near future in the Netherlands many reservoirs will have to be built to abate the pollution of the surface water by overflowing storm water from combined sewer systems [Kluck, 1992-a]. These reservoirs, called storm water sedimentation tanks, reduce the pollution in two ways. The most

  8. Assessment of the effect of rainfall dynamics on the storm overflow performance

    Directory of Open Access Journals (Sweden)

    Szeląg Bartosz

    2016-06-01

    Full Text Available Assessment of the effect of rainfall dynamics on the storm overfl ow performance. This research study analyzes the effect of the rainfall characteristics (total and maximum 10-, 15- and 30-minute rainfall depth, its duration, the dry weather period on the performance of the emergency overflow weir located at the inflow to an existing treatment plant. The analyses used the numerical calculation results of the inflow hydrographs performed in the SWMM (Storm Water Management Model program on the basis of six-year-long rainfall measurement sequence. The obtained simulation results for the analysed catchment allowed for the performance of statistical analyses, which demonstrated that the volume of stormwater discharge, the maximum instantaneous flow and the share of stormwater volume discharged through the emergency overflow weir in relation to the total volume of the inflow hydrograph from the catchment are affected by the maximum 30-minute rainfall depth, whereas the discharge duration is affected by the depth of the catchment rainfall layer. Taking into account the results of statistical and hydraulic calculations it can be concluded that in the case of the analysed catchment the performance of the emergency overflow weir is affected to the greatest extent by the rainfall intensity distribution.

  9. Integrating retention soil filters into urban hydrologic models - Relevant processes and important parameters

    Science.gov (United States)

    Bachmann-Machnik, Anna; Meyer, Daniel; Waldhoff, Axel; Fuchs, Stephan; Dittmer, Ulrich

    2018-04-01

    Retention Soil Filters (RSFs), a form of vertical flow constructed wetlands specifically designed for combined sewer overflow (CSO) treatment, have proven to be an effective tool to mitigate negative impacts of CSOs on receiving water bodies. Long-term hydrologic simulations are used to predict the emissions from urban drainage systems during planning of stormwater management measures. So far no universally accepted model for RSF simulation exists. When simulating hydraulics and water quality in RSFs, an appropriate level of detail must be chosen for reasonable balancing between model complexity and model handling, considering the model input's level of uncertainty. The most crucial parameters determining the resultant uncertainties of the integrated sewer system and filter bed model were identified by evaluating a virtual drainage system with a Retention Soil Filter for CSO treatment. To determine reasonable parameter ranges for RSF simulations, data of 207 events from six full-scale RSF plants in Germany were analyzed. Data evaluation shows that even though different plants with varying loading and operation modes were examined, a simple model is sufficient to assess relevant suspended solids (SS), chemical oxygen demand (COD) and NH4 emissions from RSFs. Two conceptual RSF models with different degrees of complexity were assessed. These models were developed based on evaluation of data from full scale RSF plants and column experiments. Incorporated model processes are ammonium adsorption in the filter layer and degradation during subsequent dry weather period, filtration of SS and particulate COD (XCOD) to a constant background concentration and removal of solute COD (SCOD) by a constant removal rate during filter passage as well as sedimentation of SS and XCOD in the filter overflow. XCOD, SS and ammonium loads as well as ammonium concentration peaks are discharged primarily via RSF overflow not passing through the filter bed. Uncertainties of the integrated

  10. Measurement of infiltration rates in urban sewer systems by use of oxygen isotopes.

    Science.gov (United States)

    De Bénédittis, J; Bertrand-Krajewski, J L

    2005-01-01

    The paper presents the principle of a method to measure infiltration rates in sewer systems based on the use of oxygen isotopes and its application in Lyon (France). In the urban area of Lyon, significant differences in delta 18O that can reach 3 per thousand are observed between the oxygen isotopic compositions of groundwater originating from Rhone, Saone and from their associated alluvial aquifers. Drinking water supplying Lyon results mainly from pumping in the Rhone alluvial aquifer. Therefore, in some areas, the difference of isotopic composition between wastewater resulting from the consumption of drinking water and local groundwater can be used to measure infiltration in sewer systems. The application in the catchment of Ecully shows that the infiltration flow rate presents strong fluctuations at an hourly scale: it varies between 15 and 40 m3/h. This variability could be explained by non-constant discharges of pumping and by variations of the water level in the sewer.

  11. Population ecology and movement of the American cockroach (Dictyoptera: Blattidae) in sewers.

    Science.gov (United States)

    Tee, Hui-Siang; Saad, Ahmad Ramli; Lee, Chow-Yang

    2011-07-01

    The population size, age-class structure, and movement of the American cockroach, Periplaneta americana (L.) (Dictyoptera: Blattidae), were studied in three sewers in Penang, Malaysia, from September 2008 to October 2009. Eighteen to 20 glass-jar traps (two per manhole) were deployed for a 24-h period during each sampling occasion at each sewer. Adults and nymphs were active throughout the study period, with an average monthly trap catch of 57-97 adults and 79-99 nymphs. The mean proportions of adults and nymphs at the three sewers ranged from 0.47 to 0.57. Of the 2177 male and 2717 female cockroaches marked and released over the three sewers, recapture rates were 29.4-45.8 and 30.8-47.0%, respectively. The proportion of marked males and females did not differ significantly from the proportion of recaptured marked males and females. However, the mean number of times a marked female was recaptured was significantly greater than that of males. Of the 783 males and 1,030 females that were marked and recaptured, 19.4 and 24.7%, respectively, had moved between manholes, and significantly more females than males moved between manholes. Of the 406 recaptured marked adults that moved between manholes, 90.4% moved a distance of 2-20 m from their initial release site; one male moved 192 m, the longest distance recorded. Trap catch on each sampling occasion was positively correlated with daily mean temperature. The number of cockroach movements between manholes also was correlated with the mean daily minimum temperature.

  12. Dotación de un sistema de alcantarillado para la Comunidad Río Arriba

    OpenAIRE

    Baquero Mora, David Alberto; Cevallos Puma, Henry Daniel

    2016-01-01

    The technical project “Provision of a sewerage system for the river up community” It will improve the living conditions for the people living in the area, since currently there is not a sanitary sewer system or storm sewer system available, so the habitants use septic tanks. The septic tanks are collapsing and producing pollution, causing environmental damage and pollution, causing environmental damage and contamination effects harmful to the habitants. The main goal is to p...

  13. Controlling sewer systems – a critical review based on systems in three EU cities

    DEFF Research Database (Denmark)

    Mollerup, Ane Loft; Mikkelsen, Peter Steen; Thornberg, D.

    2017-01-01

    The term Real Time Control (RTC) is widely used to describe all types of control systems in sewer systems. Today the term covers everything from the simplest to the most advanced types of control systems, making it difficult to communicate about sewer system control in a precise manner, as well...... as search and find specific types of control systems for comparison. Through a survey of implemented control systems in three EU cities today and with the perspectives of current research within the field of sewer system control, the needs for a new control system design framework is identified....... With the basis of existing frameworks for control system design, a new time-scale dependent framework is proposed. We believe this comprehensive time-scale dependent framework can help water utilities to retrofit and design new control solutions and facilitate knowledge sharing about existing designs....

  14. Uncovering the secret lives of sewer rats (Rattus norvegicus): Movements, distribution and population dynamics revealed by a capture-mark-recapture study

    DEFF Research Database (Denmark)

    Heiberg, Ann-Charlotte; Sluydts, Vincent; Leirs, Herwig E.l.

    2012-01-01

    Context.: In many parts of the world, brown rats have colonised sewer systems and the rat populations in sewers are often thought to be a source of problems with rats on the surface. The management of sewer rat populations is usually performed with little, if any, knowledge of the dynamics and be...

  15. [Evaluation of the sanitary-and-epidemiological hazard of solid garbage in Astana].

    Science.gov (United States)

    Gumarova, Zh Zh; Bekshin, Zh M; Aushakhmetova, Z T

    2008-01-01

    According to the national plan of actions on environmental protection, industrial garbage recycling is to be introduced in Almaty and Astana for the sustainable development of the Republic of Kazakhstan. Integrated assessment of the hazard of garage is made by the sanitary-and-chemical and sanitary-and-epidemiological indices to provide the hygienic and ecological reliability of a procedure for neutralization and utilization of solid garbage (SG). According to the data obtained, Astana SG Astana in summer is characterized by the high total level of bacterial contamination. The indices of microbial contamination of SG and soil near the dustbins correlate with the density of population and the maturity of an infrastructure. Comparison of the sanitary-and-epidemiological indices of different types of SG (wastes from housing facilities, wholesale and retail outlays, and education, culture, and entertainment institutions) revealed no significant differences. According to the sanitary-and-helmintological indices, the Astana soil should be classified as pure (noninvasive). Involvement of SG into industrial recycling should be accompanied by a hygienic assessment of the hazard of waste and the reliability of used technologies in the context of warning and on-going sanitary surveillance.

  16. Accounting for Mass Transfer Kinetics when Modeling the Impact of Low Permeability Layers in a Groundwater Source Zone on Dissolved Contaminant Fate and Transport

    Science.gov (United States)

    2014-03-27

    Clay Interface) ...................................................................................................... 40 Figure 9: Time-Dependent...vs Constant Dissolution Rate BTCs (Monitoring Well in Clay ...pits, poured down sanitary sewer systems, and partially burned in fire training pits. Poor handling and disposal of chlorinated solvents have

  17. Application of the Wallingford Procedure to sewer network rehabilitation. Rehabilitacion de redes de alcantarillado. Aplicando el sistema de Wallingford

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, M. (Universidad Politecnica de de Cataluna. Barcelona (Spain)); Lopez, R. (Universitat de Lleida. Lleida (Spain))

    1999-01-01

    In this paper we present a summary of the Wallingford Procedure application to sewer network rehabilitation studies. After the methodology of the Procedure is revised, an application to a sewer network of Sant Boi de Llobregat is showed. Flow survey campaigns, calibration and validation processes and the alternative proposed to improve the initial situation are described. Finally, the benefits to apply such methodologies to the sewer network rehabilitation analysis are exposed. (Author) 3 refs.

  18. Application of the Wallingford Procedure to sewer network rehabilitation; Rehabilitacion de redes de alcantarillado. Aplicando el sistema de Wallingford

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, M. [Universidad Politecnica de de Cataluna. Barcelona (Spain); Lopez, R. [Universitat de Lleida. Lleida (Spain)

    1999-11-01

    In this paper we present a summary of the Wallingford Procedure application to sewer network rehabilitation studies. After the methodology of the Procedure is revised, an application to a sewer network of Sant Boi de Llobregat is showed. Flow survey campaigns, calibration and validation processes and the alternative proposed to improve the initial situation are described. Finally, the benefits to apply such methodologies to the sewer network rehabilitation analysis are exposed. (Author) 3 refs.

  19. Release of hydrogen sulfide in a sewer system under intermittent flow conditions

    DEFF Research Database (Denmark)

    Matias, Natércia; Matos, Rita Ventura; Ferreira, Filipa

    2017-01-01

    The presence and fate of hydrogen sulfide in wastewater systems were studied in two stretches of an intercepting sewer system located in a coastal village, in Portugal. A range of hydraulic parameters were obtained and liquid and gas phase measurements were carried out, both continuously and thro......The presence and fate of hydrogen sulfide in wastewater systems were studied in two stretches of an intercepting sewer system located in a coastal village, in Portugal. A range of hydraulic parameters were obtained and liquid and gas phase measurements were carried out, both continuously...... authors’ publications addressing relatively small pipes and moderate water flows....

  20. Airflow in Gravity Sewers - Determination of Wastewater Drag Coefficient.

    Science.gov (United States)

    Bentzen, Thomas Ruby; Østertoft, Kristian Kilsgaard; Vollertsen, Jes; Fuglsang, Emil Dietz; Nielsen, Asbjørn Haaning

    2016-03-01

    Several experiments have been conducted in order to improve the understanding of the wastewater drag and the wall frictional force acting on the headspace air in gravity sewers. The aim of the study is to improve the data basis for a numerical model of natural sewer ventilation. The results of the study shows that by integrating the top/side wall shear stresses the log-law models for the air velocity distribution along the unwetted perimeter resulted in a good agreement with the friction forces calculated by use of the Colebrook-White formula for hydraulic smooth pipes. Secondly, the water surface drags were found by log-law models of the velocity distribution in turbulent flows to fit velocity profiles measured from the water surface and by integrating the water surface drags along the wetted perimeter, mean water surface drags were found and a measure of the water surface drag coefficient was found.

  1. Association between Gastrointestinal Illness and Precipitation in Areas Impacted by Combined Sewer Systems: Utilizing a Distributed Lag Model

    Science.gov (United States)

    Combined sewer systems collect rainwater runoff, sewage, and industrial wastewater for transit to treatment facilities. With heavy precipitation, volumes can exceed capacity of treatment facilities, and wastewater discharges directly to receiving waters. These combined sewer over...

  2. Wintertime re-ventilation of the East Greenland Current's Atlantic-origin Overflow Water in the western Iceland Sea

    Science.gov (United States)

    Våge, Kjetil; Håvik, Lisbeth; Papritz, Lukas; Spall, Michael; Moore, Kent

    2017-04-01

    The Deep Western Boundary Current constitutes the lower limb of the Atlantic Meridional Overturning Circulation, and, as such, is a crucial component of the Earth's climate system. The largest and densest contribution to the current stems from the overflow plume that passes through Denmark Strait. A main source of Denmark Strait Overflow Water (DSOW) is the East Greenland Current (EGC). The DSOW transported by the EGC originates from the Atlantic inflow into the Nordic Seas. This is then transformed into Atlantic-origin Overflow Water while progressing northward through the eastern part of the Nordic Seas. Here we show, using measurements from autonomous gliders deployed from fall 2015 to spring 2016, that the Atlantic-origin Overflow Water transported toward Denmark Strait by the EGC was re-ventilated while transiting the western Iceland Sea in winter. In summer, this region is characterized by an upper layer of cold, fresh Polar Surface Water that is thought to prevent convection. But in fall and winter this fresh water mass is diverted toward the Greenland shelf by enhanced northerly winds, which results in a water column that is preconditioned for convection. Severe heat loss from the ocean to the atmosphere offshore of the ice edge subsequently causes the formation of deep mixed layers. This further transforms the Atlantic-origin Overflow Water and impacts the properties of the DSOW, and hence the deepest and densest component of the lower limb of the Atlantic Meridional Overturning Circulation.

  3. Identification of controlling factors for the initiation of corrosion of fresh concrete sewers.

    Science.gov (United States)

    Jiang, Guangming; Sun, Xiaoyan; Keller, Jurg; Bond, Philip L

    2015-09-01

    The development of concrete corrosion in new sewer pipes undergoes an initiation process before reaching an active corrosion stage. This initiation period is assumed to last several months to years but the key factors affecting the process, and its duration, are not well understood. This study is therefore focused on this initial stage of the corrosion process and the effect of key environmental factors. Such knowledge is important for the effective management of corrosion in new sewers, as every year of life extension of such systems has a very high financial benefit. This long-term (4.5 year) study has been conducted in purpose-built corrosion chambers that closely simulated the sewer environment, but with control of three key environmental factors being hydrogen sulfide (H2S) gas phase concentration, relative humidity and air temperature. Fresh concrete coupons, cut from an industry-standard sewer pipe, were exposed to the corrosive conditions in the chambers, both in the gas phase and partially submerged in wastewater. A total of 36 exposure conditions were investigated to determine the controlling factors by regular retrieval of concrete coupons for detailed analysis of surface pH, sulfur compounds (elemental sulfur and sulfate) and concrete mass loss. Corrosion initiation times were thus determined for different exposure conditions. It was found that the corrosion initiation time of both gas-phase and partially-submerged coupons was positively correlated with the gas phase H2S concentration, but only at levels of 10 ppm or below, indicating that sulfide oxidation rate rather than the H2S concentration was the limiting factor during the initiation stage. Relative humidity also played a role for the corrosion initiation of the gas-phase coupons. However, the partially-submerged coupons were not affected by humidity as these coupons were in direct contact with the sewage and hence did have sufficient moisture to enable the microbial processes to proceed. The

  4. Investigations to identify organic pollutions in sewer slime. Final report; Untersuchungen zur Identifizierung organischer Schadstoffe in Sielhaeuten. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Antusch, E.; Sauer, J.; Ripp, C.; Hahn, H.H.

    1997-07-31

    An analytical method to measure organic compounds in sewer slime and sewage sludge has been developed. The method needs no halogenated solvents. Furthermore, the sorption behavior of sewer slime has been investigated. Chlorophenols, as an example of more polar organic compounds, show a more stronger and faster desorption from sewer slime than for example PAH. pH-value and fat-content (resp. content of organic carbon) are the most important parameters affecting the sorption kinetic and sorption capacity of sewer slime. To get comparable results, all datas should be refered to the content of organic carbon of the sewer slime. By constructing pollutions-profiles of parameters like AOX, PCB, Flame Protection Agencies and PAH in the sewers of an industrial area, emissions could be localized. (orig.) [Deutsch] Es wurde eine analytische Methode entwickelt, die es erlaubt, ein breites Spektrum lipophiler organischer Schadstoffe in Sielhaut und Klaerschlamm zu identifizieren, als quantitativ zu bestimmen. Die Methode kommt ohne halogenierte Loesungsmittel aus. Verbindungen, die aufgrund ihrer Wasserunloeslichkeit nicht im Abwasser nachgewiesen werden konnten, koennen durch Sielhautanalyse verfolgt werden. Anhand von Schadstoffprofilen in Nebensammlern eines Industriegebietes konnte beispielhaft die Lokalisierung von punktfoermigen Schadstoffeinleitungen demonstriert werden. Erfolgreich verlief auch die Identifizierung eines AOX-Emittenten. Ebenso sind die Eintragspfade von Stoffen, die im Verdacht stehen, endokrine Wirkungen zu haben mit Sielhautanalyse aufklaerbar. Das Sorptionsverhalten der Sielhaut wird durch Faktoren, wie pH und Fettgehalt gepraegt. Bei der Auswertung der Proben muessen die Werte auf den organischen Kohlenstoffgehalt bezogen werden. (orig.)

  5. Deterministic Versus Stochastic Interpretation of Continuously Monitored Sewer Systems

    DEFF Research Database (Denmark)

    Harremoës, Poul; Carstensen, Niels Jacob

    1994-01-01

    An analysis has been made of the uncertainty of input parameters to deterministic models for sewer systems. The analysis reveals a very significant uncertainty, which can be decreased, but not eliminated and has to be considered for engineering application. Stochastic models have a potential for ...

  6. Factors affecting long-term trends in surface-water quality in the Gwynns Falls watershed, Baltimore City and County, Maryland, 1998–2016

    Science.gov (United States)

    Majcher, Emily H.; Woytowitz, Ellen L.; Reisinger, Alexander J.; Groffman, Peter M.

    2018-03-30

    trends, and total phosphorus and chloride show upward trends.Sanitary sewer overflows (gray infrastructure) and best management practices (green infrastructure) were identified as factors affecting water-quality change. The duration of sanitary sewer overflows was positively correlated with annual loads of nutrients and bacteria, and the drainage area of best management practices was negatively correlated with annual loads of phosphate and sulfate. Results of the study indicate that continued investments in gray and green infrastructure are necessary for urban water-quality improvement. Although this outcome is not unexpected, long-term datasets such as the one used in this study, allow the effects of gray and green infrastructures to be quantified.Results of this study have implications for the Gwynns Falls watershed and its residents and Baltimore City and County managers. Moreover, outcomes are relevant to other watersheds in the metropolitan region that do not have the same long-term dataset. Further, this study has established a framework for ongoing statistical analysis of primary factors affecting urban water-quality trends as regulatory programs mature.

  7. Feasibility of sulfide control in sewers by reuse of iron rich drinking water treatment sludge.

    Science.gov (United States)

    Sun, Jing; Pikaar, Ilje; Sharma, Keshab Raj; Keller, Jürg; Yuan, Zhiguo

    2015-03-15

    Dosage of iron salt is the most commonly used method for sulfide control in sewer networks but incurs high chemical costs. In this study, we experimentally investigate the feasibility of using iron rich drinking water treatment sludge for sulfide control in sewers. A lab-scale rising main sewer biofilm reactor was used. The sulfide concentration in the effluent decreased from 15.5 to 19.8 mgS/L (without dosing) to below 0.7-2.3 mgS/L at a sludge dosing rate achieving an iron to total dissolved inorganic sulfur molar ratio (Fe:S) of 1:1, with further removal of sulfide possible by prolonging the reaction time. In fact, batch tests revealed an Fe consumption to sulfide removal ratio of 0.5 ± 0.02 (mole:mole), suggesting the possible occurrence of other reactions involving the removal of sulfide. Modelling revealed that the reaction between iron in sludge and sulfide has reaction orders of 0.65 ± 0.01 and 0.77 ± 0.02 with respect to the Fe and sulfide concentrations, respectively. The addition of sludge slightly increased the total chemical oxidation demand (tCOD) concentration (by approximately 12%) as expected, but decreased the soluble chemical oxidation demand (sCOD) concentration and methane formation by 7% and 20%, respectively. Some phosphate removal (13%) was also observed at the sludge dosing rate of 1:1 (Fe:S), which is beneficial to nutrient removal from the wastewater. Overall, this study suggests that dosing iron-rich drinking water sludge to sewers could be an effective strategy for sulfide removal in sewer systems, which would also reduce the sludge disposal costs for drinking water treatment works. However, its potential side-effects on sewer sedimentation and on the wastewater treatment plant effluent remain to be investigated. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Comparison of the sanitary effects of energy chains. Methodological aspects

    International Nuclear Information System (INIS)

    Fagnani, F.

    1979-01-01

    Beyond technical and economical matters, the development of an industrial technology involves more or less numerous indirect consequences. From this viewpoint, the author analysis the methodological problems raised in evaluating the sanitary and ecological problems of the different energy-producing lines and considers successively the matter of technical interdependences, protection and safety regulations and selection of sites, classification of risks and measuring problems in relation to sanitary effects [fr

  9. Fats, oils, and grease : options for plant-level treatment of a national problem

    Energy Technology Data Exchange (ETDEWEB)

    Miles, E.; Scherffius, B. [EcoPlus Inc. Charlotte, NC (United States)

    2007-09-15

    Fats, oils, and grease from restaurants and homes can congeal in sewers and result in damaging runoff into rivers and streams. A growing number of food service establishments are now producing increasing amounts of a specific grease product called brown grease, which is sticky and difficult to remove. Regulations now require haulers to remove the waste and dispose of it. However, many local treatment plants cannot accept or dispose of the amounts of grease currently being produced. A total of volume of 3 to 10 billion gallons per year of contaminated water have been accidentally discharged from sanitary sewers as a result of brown grease accumulations. This paper provided details of the EcoPlus Final Treatment Facility, which can be set up at waste water treatment plants and is able to process brown grease and discharge supernatant water from its process back into city sewers. The EcoPlus process produces 2 waste streams: (1) a low strength aqueous solution that can be disposed of in a sanitary sewer tap; and (2) a granular material that can be disposed of in a landfill for use as a soil conditioner. It was concluded that the granular material can also be used facilitate the incineration of sewage sludge, or burned as an alternative green fuel for power generation. 4 figs.

  10. A mathematical model to predict the effect of heat recovery on the wastewater temperature in sewers.

    Science.gov (United States)

    Dürrenmatt, David J; Wanner, Oskar

    2014-01-01

    Raw wastewater contains considerable amounts of energy that can be recovered by means of a heat pump and a heat exchanger installed in the sewer. The technique is well established, and there are approximately 50 facilities in Switzerland, many of which have been successfully using this technique for years. The planning of new facilities requires predictions of the effect of heat recovery on the wastewater temperature in the sewer because altered wastewater temperatures may cause problems for the biological processes used in wastewater treatment plants and receiving waters. A mathematical model is presented that calculates the discharge in a sewer conduit and the spatial profiles and dynamics of the temperature in the wastewater, sewer headspace, pipe, and surrounding soil. The model was implemented in the simulation program TEMPEST and was used to evaluate measured time series of discharge and temperatures. It was found that the model adequately reproduces the measured data and that the temperature and thermal conductivity of the soil and the distance between the sewer pipe and undisturbed soil are the most sensitive model parameters. The temporary storage of heat in the pipe wall and the exchange of heat between wastewater and the pipe wall are the most important processes for heat transfer. The model can be used as a tool to determine the optimal site for heat recovery and the maximal amount of extractable heat. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Relationships and trends of E. Coli, human-associated Bacteroides, and pathogens in the Proctor Creek Watershed

    Science.gov (United States)

    Urban surface waters can be impacted by anthropogenic sources such as impervious surfaces, sanitary and storm sewers, and failing infrastructure. Fecal indicator bacteria (FIB) and microbial source tracking (MST) markers are common gauges of stream water quality, however, little...

  12. [Ways of urban sanitary and epidemiological well-being management].

    Science.gov (United States)

    Kreĭmer, M A

    2010-01-01

    The scientific rationale for preventive measures based on sanitary-and-epidemiological surveillance on environmental objects is considered. The sizes of functional zones and space for various types of communal services and amenities and leisure are regulated to ensure good urban vital activities. Multistorey housing causes an increase in the number of negative factors per area units and in their impact on health. A proposal has been made for the standardization of the ranges of urban population upsurge and size, by using the sanitary-and-hygienic rules and norms rather than climatic parameters. A criterion system for assessing the data of statistical observations has been substantiated and 5 levels of analysis and managerial decision-making have been proposed. Cause-and-effect relations may be determined for the parameters of the second level; models of program-oriented studies for the third level, only sanitary-and-epidemiological surveillance is possible for the fourth and fifth levels. The space planning scheme must provide for water supply reserves, generation areas for pure air coming into the town, and waste disposal areas. The general layout may use statistical observation parameters characterizing the second level of occurrence of negative phenomena. The statistical observation parameters characterizing the third and fourth levels of occurrence of negative phenomena may be used for municipal improvements and sanitary maintenance. These characterizing the fourth and fifth level may be used for prevention in therapeutic-and-prophylactic institutions.

  13. A Monte-Carlo-Based Method for the Optimal Placement and Operation Scheduling of Sewer Mining Units in Urban Wastewater Networks

    Directory of Open Access Journals (Sweden)

    Eleftheria Psarrou

    2018-02-01

    Full Text Available Pressures on water resources, which have increased significantly nowadays mainly due to rapid urbanization, population growth and climate change impacts, necessitate the development of innovative wastewater treatment and reuse technologies. In this context, a mid-scale decentralized technology concerning wastewater reuse is that of sewer mining. It is based on extracting wastewater from a wastewater system, treating it on-site and producing recycled water applicable for non-potable uses. Despite the technology’s considerable benefits, several challenges hinder its implementation. Sewer mining disturbs biochemical processes inside sewers and affects hydrogen sulfide build-up, resulting in odor, corrosion and health-related problems. In this study, a tool for optimal sewer mining unit placement aiming to minimize hydrogen sulfide production is presented. The Monte-Carlo method coupled with the Environmental Protection Agency’s Storm Water Management Model (SWMM is used to conduct multiple simulations of the network. The network’s response when sewage is extracted from it is also examined. Additionally, the study deals with optimal pumping scheduling. The overall methodology is applied in a sewer network in Greece providing useful results. It can therefore assist in selecting appropriate locations for sewer mining implementation, with the focus on eliminating hydrogen sulfide-associated problems while simultaneously ensuring that higher water needs are satisfied.

  14. Environmental assessment of sewer construction in small to medium sized cities using life cycle assessment

    OpenAIRE

    Petit, Anna

    2014-01-01

    In a world with an increasing urban population, analysing the construction impacts of sanitation infrastructures through Life Cycle Assessment (LCA) is necessary for defining the best environmental management strategies. In this study, the environmental impacts of one linear meter of sewer constructive solution were analysed for different pipe materials and diameters used in Southern Europe; a unit of different sewer appurtenances (pump, manhole and inspection chamber) was also considered. Th...

  15. COMBINED AND STORM SEWER NETWORK MONITORING

    OpenAIRE

    Justyna Synowiecka; Ewa Burszta-Adamiak; Tomasz Konieczny; Paweł Malinowski

    2014-01-01

    Monitoring of the drainage networks is an extremely important tool used to understand the phenomena occurring in them. In an era of urbanization and increased run-off, at the expense of natural retention in the catchment, it helps to minimize the risk of local flooding and pollution. In its scope includes measurement of the amount of rainfall, with the use of rain gauges, and their measure in the sewer network, in matter of flows and channel filling, with the help of flow meters. An indispens...

  16. Determination of an Optimal Trunk Sewer-line Route for Kikuyu ...

    African Journals Online (AJOL)

    The proposed route utilises the existing road reserves, which help in minimising the costs ... and industries and conveys it using sewer pipes to a treatment works where it is treated and ..... Automating Utility Route Design and Planning through.

  17. Application of a leakage model to assess exfiltration from sewers.

    Science.gov (United States)

    Karpf, C; Krebs, P

    2005-01-01

    The exfiltration of wastewater from sewer systems in urban areas causes a deterioration of soil and possibly groundwater quality. Beside the simulation of transport and degradation processes in the unsaturated zone and in the aquifer the analysis of the potential impact requires the estimation of quantity and temporal variation of wastewater exfiltration. Exfiltration can be assessed by the application of a leakage model. The hydrological approach was originally developed to simulate the interactions between the groundwater and surface water, it was adapted to allow for modelling of interactions between groundwater and sewer system. In order to approximate the exfiltration specific model parameters infiltration specific parameters were used as a basis. Scenario analysis of the exfiltration in the City of Dresden from 1997 to 1999 and during the flood event in August 2002 shows the variation and the extent of exfiltration rates.

  18. Relationships and trends of E. Coli, human-associated bacteroides, and pathogens in the Proctor Creek watershed (GWRC 2017)

    Science.gov (United States)

    Urban surface waters can be impacted by anthropogenic sources such as impervious surfaces, sani-tary and storm sewers, and failing infrastructure. Fecal indicator bacteria (FIB) and microbial source tracking (MST) markers are common gauges of stream water qual-ity, however, litt...

  19. The SWOT Analysis of a Romanian Post-Sanitary Institution in Romania

    Directory of Open Access Journals (Sweden)

    Cristina Iorga

    2016-01-01

    Starting from a comprehensive research (literature review, the paper proposes the realization of aSWOT analysis within a post-sanitary school, which aims at emphasizing the main advantages of apost-secondary schools perceived by students and discovering major development opportunities forthe quality of services offered by it, as a premise of the improvement of the sanitary schools, andthus, the health system in Romania.

  20. Metamorphic Testing Integer Overflow Faults of Mission Critical Program: A Case Study

    Directory of Open Access Journals (Sweden)

    Zhanwei Hui

    2013-01-01

    Full Text Available For mission critical programs, integer overflow is one of the most dangerous faults. Different testing methods provide several effective ways to detect the defect. However, it is hard to validate the testing outputs, because the oracle of testing is not always available or too expensive to get, unless the program throws an exception obviously. In the present study, the authors conduct a case study, where the authors apply a metamorphic testing (MT method to detect the integer overflow defect and alleviate the oracle problem in testing critical program of Traffic Collision Avoidance System (TCAS. Experimental results show that, in revealing typical integer mutations, compared with traditional safety property testing method, MT with a novel symbolic metamorphic relation is more effective than the traditional method in some cases.

  1. Long-term Simulation of the Removal of Pollutants in Retention Basins

    DEFF Research Database (Denmark)

    Larsen, Torben; Neerup-Jensen, Ole; Kaasgaard, Mogens

    2005-01-01

    -dependant sedimentation and the variation of the settling velocity of the particles. The results show that including these effects lead to significant lower discharges of pollutants compared to conventional methods of estimation. As an example computations with a spectrum of basins which cover realistic sizes show......The paper describes a method for the long-term simulation of the discharge of pollutants to the environment from storm sewer overflows in combined sewer systems, which has a connected retention basin. This study covers Cd, Cu, Ni, Pb, Zn and PAH. The method includes both the influence of the flow...

  2. Colorado River Sewer System Joint Venture to Upgrade Wastewater System

    Science.gov (United States)

    SAN FRANCISCO -Today, the Colorado River Sewer System Joint Venture, located in Parker, Ariz. entered into an agreement with the EPA to upgrade their wastewater treatment system to meet stringent water quality standards. The cost of the upgrade is ap

  3. Biogas of sanitary fillers

    International Nuclear Information System (INIS)

    Serrano Camacho, Ciro

    2007-01-01

    The author proposes a methodology for the preliminary estimation of the energetic potential and environmental improvement derivates of the implementation of these technologies that allows to make the first estimative of biogas generation of sanitary fillers with base in the results of the simulation of three predictive model: One Mexican, other denominated Scholl-Canyon of North American origin and the designed by the EPA. The three models use different versions and constants for a differential equation of degradation of first degree

  4. Importance Sampling Simulation of Population Overflow in Two-node Tandem Networks

    NARCIS (Netherlands)

    Nicola, V.F.; Zaburnenko, T.S.; Baier, C; Chiola, G.; Smirni, E.

    2005-01-01

    In this paper we consider the application of importance sampling in simulations of Markovian tandem networks in order to estimate the probability of rare events, such as network population overflow. We propose a heuristic methodology to obtain a good approximation to the 'optimal' state-dependent

  5. Conservative Overset Grids for Overflow For The Sonic Wave Atmospheric Propagation Project

    Science.gov (United States)

    Onufer, Jeff T.; Cummings, Russell M.

    1999-01-01

    Methods are presented that can be used to make multiple, overset grids communicate in a conservative manner. The methods are developed for use with the Chimera overset method using the PEGSUS code and the OVERFLOW solver.

  6. Assisting in Auditing of Buffer Overflow Vulnerabilities via Machine Learning

    Directory of Open Access Journals (Sweden)

    Qingkun Meng

    2017-01-01

    Full Text Available Buffer overflow vulnerability is a kind of consequence in which programmers’ intentions are not implemented correctly. In this paper, a static analysis method based on machine learning is proposed to assist in auditing buffer overflow vulnerabilities. First, an extended code property graph is constructed from the source code to extract seven kinds of static attributes, which are used to describe buffer properties. After embedding these attributes into a vector space, five frequently used machine learning algorithms are employed to classify the functions into suspicious vulnerable functions and secure ones. The five classifiers reached an average recall of 83.5%, average true negative rate of 85.9%, a best recall of 96.6%, and a best true negative rate of 91.4%. Due to the imbalance of the training samples, the average precision of the classifiers is 68.9% and the average F1 score is 75.2%. When the classifiers were applied to a new program, our method could reduce the false positive to 1/12 compared to Flawfinder.

  7. Proposals for future activities agreed upon at the seminar on wastewater treatment in urban areas

    International Nuclear Information System (INIS)

    1987-01-01

    The programme of the seminar was divided into three different sections: - Sewerage systems, - Discharge of industrial wastewater to municipal sewerage systems, - Reduction of nitrogen. For each subject the participants of the seminar agreed upon the following proposal for future activities: Sewerage systems: a) Combined sewer overflows (CSO). Brief state-of-the-art reports should be compiled by the Contracting Parties. The reports should provide information on: - extent of combined sewers (in % of sewered area), - design practices including flow equalization, - rates of inflow/infiltration, - pollution due to CSO, - current research, - trends. A compilation of these reports may hopefully lead to the derivation of suitable effluent standards, which may be expressed as frequencies, total volumes or total amount of pollution load. The effluent standards may be expressed as monthly to yearly values

  8. Stochastic modeling of total suspended solids (TSS) in urban areas during rain events.

    Science.gov (United States)

    Rossi, Luca; Krejci, Vladimir; Rauch, Wolfgang; Kreikenbaum, Simon; Fankhauser, Rolf; Gujer, Willi

    2005-10-01

    The load of total suspended solids (TSS) is one of the most important parameters for evaluating wet-weather pollution in urban sanitation systems. In fact, pollutants such as heavy metals, polycyclic aromatic hydrocarbons (PAHs), phosphorous and organic compounds are adsorbed onto these particles so that a high TSS load indicates the potential impact on the receiving waters. In this paper, a stochastic model is proposed to estimate the TSS load and its dynamics during rain events. Information on the various simulated processes was extracted from different studies of TSS in urban areas. The model thus predicts the probability of TSS loads arising from combined sewer overflows (CSOs) in combined sewer systems as well as from stormwater in separate sewer systems in addition to the amount of TSS retained in treatment devices in both sewer systems. The results of this TSS model illustrate the potential of the stochastic modeling approach for assessing environmental problems.

  9. 30 CFR 71.402 - Minimum requirements for bathing facilities, change rooms, and sanitary flush toilet facilities.

    Science.gov (United States)

    2010-07-01

    ... nonirritating cleansing agent shall be provided for use at each shower. (2) Sanitary flush toilet facilities. (i..., change rooms, and sanitary flush toilet facilities. 71.402 Section 71.402 Mineral Resources MINE SAFETY... Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.402 Minimum requirements for...

  10. Coordinated activation of PTA-ACS and TCA cycles strongly reduces overflow metabolism of acetate in Escherichia coli.

    Science.gov (United States)

    Peebo, Karl; Valgepea, Kaspar; Nahku, Ranno; Riis, Gethe; Oun, Mikk; Adamberg, Kaarel; Vilu, Raivo

    2014-06-01

    Elimination of acetate overflow in aerobic cultivation of Escherichia coli would improve many bioprocesses as acetate accumulation in the growth environment leads to numerous negative effects, e.g. loss of carbon, inhibition of growth, target product synthesis, etc. Despite many years of studies, the mechanism and regulation of acetate overflow are still not completely understood. Therefore, we studied the growth of E. coli K-12 BW25113 and several of its mutant strains affecting acetate-related pathways using the continuous culture method accelerostat (A-stat) at various specific glucose consumption rates with the aim of diminishing acetate overflow. Absolute quantitative exo-metabolome and proteome analyses coupled to metabolic flux analysis enabled us to demonstrate that onset of acetate overflow can be postponed and acetate excretion strongly reduced in E. coli by coordinated activation of phosphotransacetylase-acetyl-CoA synthetase (PTA-ACS) and tricarboxylic acid (TCA) cycles. Fourfold reduction of acetate excretion (2 vs. 8 % from total carbon) at fastest growth compared to wild type was achieved by deleting the genes responsible for inactivation of acetyl-CoA synthetase protein (pka) and TCA cycle regulator arcA. The Δpka ΔarcA strain did not accumulate any other detrimental by-product besides acetate and showed identical μ max and only ~5 % lower biomass yield compared to wild type. We conclude that a fine-tuned coordination between increasing the recycling capabilities of acetate in the PTA-ACS node through a higher concentration of active acetate scavenging Acs protein and downstream metabolism throughput in the TCA cycle is necessary for diminishing overflow metabolism of acetate in E. coli and achieving higher target product production in bioprocesses.

  11. PROPOSAL OF SANITARY MANAGEMENT OF EDIBLE ECHINODERMS IN SARDINIA

    Directory of Open Access Journals (Sweden)

    G. Terrosu

    2011-01-01

    Full Text Available Sea urchin (Paracentrotus lividus is an edible echinoderm very common in the Mediterranean sea. In the Sardinian gastronomic tradition it represents a product very used in some periods of the year, but in practice the sanitary controls by the competent authorities are very difficult. The Reg. (EC n. 853/2004 provides that, as regards as the control on production, echinoderms are assimilable to live bivalve molluscs, with the exception of the provisions on purification. In this work a proposal for the sanitary management of the phases of gathering, transport and selling of the sea urchins has been studied.

  12. [Sanitary control of food in Mexico city].

    Science.gov (United States)

    Sartí-Gutiérrez, E J; Parrilla-Cerrillo, C; Vázquez-Barojas, S; Kawashima-Hashimoto, L; Farías-Rodríguez, A; García-Juárez, C

    1989-01-01

    This work was undertaken as to avoid health risks to tourism in the "XIIth Soccer World Cup, Mexico 86". The above project was carried out through proper quality control of foods, drinking water as well as a definite care of personal hygiene of all those involved in the catering business (132 restaurants were included). The mentioned report informs only of the work of the National Public Health Laboratory in the Sanitary Epidemiological Program. The following products were analyzed: 133 water samples, 272 animated and nonliving surfaces, and 399 foods. Twenty seven percent of water samples were rejected, as well as 85% of the different surfaces and 60% of the food samples. High counts of mesophilic aerobics, followed by coliforms, S. aureus and Salmonella sp., were the principal specimens encountered. Therefore, it was suggested the permanent development of a sanitary epidemiological program.

  13. A comparison of sewer reticulation system design standards gravity ...

    African Journals Online (AJOL)

    Thirdly Botswana being a dry country does not always have the water supply available and only some households have a house connection which provides enough water to flush a gravity sewer. Coupled to this is the low housing density and generally flat landscape in rural Botswana that means the conventional gravity ...

  14. 40 CFR 122.26 - Storm water discharges (applicable to State NPDES programs, see § 123.25).

    Science.gov (United States)

    2010-07-01

    ... under interim status or a permit under subtitle C of RCRA; (v) Landfills, land application sites, and... vehicle maintenance (including vehicle rehabilitation, mechanical repairs, painting, fueling, and... sewer system. (20) Uncontrolled sanitary landfill means a landill or open dump, whether in operation or...

  15. [The sanitary and hygienic state of solid garbage burial grounds in the stages of a life cycle].

    Science.gov (United States)

    Zomarev, A M; Vaĭsman, Ia I; Zaĭtseva, T A; Glushankova, I S

    2010-01-01

    The purpose of the study was to assess the sanitary-and-hygienic state of solid garbage (SG) burial grounds in the Perm Territory in different stage of a life cycle. This paper presents the results of the study of deposited waste, forming dump soil, and SG ground emissions by general sanitary and sanitary-microbiological parameters and their effect on environmental objects. The performed studies of the sanitary-and-hygienic situation on some grounds of the Perm Territory suggest that there is a need for setting up a system for sanitary-and-monitoring of SG ground and for elaborating engineering, organizational, and prophylactic measures to assure the sanitary-and-hygienic safety of objects and to control the quality and quantity of waste to be buried and the currents of emissions (ground body degassing, filtrating sewage drainage and purification).

  16. Kinetics of aerobic oxidation of volatile sulfur compounds in wastewater and biofilm from sewers

    DEFF Research Database (Denmark)

    Rudelle, Elise Alice; Vollertsen, Jes; Hvitved-Jacobsen, Thorkild

    2013-01-01

    Laboratory experiments were conducted to investigate the kinetics of aerobic chemical and biological oxidation of selected odorous volatile sulfur compounds (VSCs) by wastewater and biofilm from sewers. The VSCs included methyl mercaptan (MeSH), ethyl mercaptan (EtSH), dimethyl sulfide (DMS......-spot downstream of a force main and the other was a gravity sewer transporting young aerobic wastewater. The kinetics of VSC oxidation for both wastewater and suspended biofilm samples followed a first-order rate equation. The average values of the reaction rate constants demonstrated the following order...... in the aerobic wastewater....

  17. 21 CFR 129.35 - Sanitary facilities.

    Science.gov (United States)

    2010-04-01

    ... HUMAN CONSUMPTION PROCESSING AND BOTTLING OF BOTTLED DRINKING WATER Buildings and Facilities § 129.35... is not considered water of a safe, sanitary quality as required for use in bottled water by paragraph... comply with bottled water quality standards (§ 165.110(b) of this chapter) and section 402(a)(1) and (a...

  18. Methodology for the design of Santa Rosa de Cabal sanitary landfill, Risaralda

    International Nuclear Information System (INIS)

    Tabares, J; Orozco, J

    1992-01-01

    In 1987 the Regional Autonomous Corporation of Risaralda, CARDER and the Risaralda Government, they signed a cooperation agreement, in order to endowing from sanitary landfill to the municipalities of the department. In the mark of this agreement it was carried out the design of Santa Rosa's sanitary landfill, that with near 50.000 inhabitants it is constituted in the third city of the department. This city generates some 25 tons/day of garbage that at the present time are heady directly to the waters of San Eugenio River. The present work contains the most important methodological aspects in the design of the sanitary landfill and some comments about the approaches ideal Vs real approaches of selection of places

  19. Stable isotopes of water as a natural tracer for infiltration into urban sewer systems

    Science.gov (United States)

    Kracht, O.; Gresch, M.; de Bénédittis, J.; Prigiobbe, V.; Gujer, W.

    2003-04-01

    An adequate understanding of the hydraulic interaction between leaky sewers and groundwater is essential for the sustainable management of both sewer systems and aquifers in urbanized areas. Undesirable infiltration of groundwater into sewers can contribute over 50% of the total discharge and is detrimental to treatment plant efficiency. On the other hand, in many European cities groundwater surface levels seem to be particularly controlled by the drainage effect of permeable sewer systems. However, nowadays methods for the quantification of these exchange processes are still subject to considerable uncertainties due to their underlying assumptions. The frequently used assumption that the night time minimum in the diurnal wastewater hydrograph is equal to the "parasitic discharge" has to be reconsidered to today's patterns of human life as well as to the long residence time of wastewater in the sewer networks of modern cities. The suitability of stable water isotopes as a natural tracer to differentiate the origin of water in the sewer ("real" wastewater or infiltrating groundwater) is currently investigated in three different catchment areas. The studies are carried out within the framework of the European research project APUSS (Assessing Infiltration and Exfiltration on the Performance of Urban Sewer Systems): 1) The village of Rümlang (Zürich, Switzerland) is predominantly served with drinking water from the Lake Zürich. A large fraction of the lakes water is derived from precipitation in the Alps. This drinking water represents the intrinsic provenience of the wastewater with an δ18O value around -11,5 per mill and δ^2H value around -82 per mill vs. SMOW. In contrast, the local groundwater is originating from precipitation in a moderate altitude of about 450 m above sea level and shows comparatively enriched mean δ18O values of -9,7 per mill and δ^2H values of -70 per mill with only small natural variations. The isotopic separation between these

  20. Evaluation of sanitary impact of environmental pollution and quantitative evaluation of sanitary risks; Estimation de l'impact sanitaire d'une pollution environnementale et evaluation quantitative des risques sanitaires

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-09-15

    The calculation of a sanitary impact present a great interest at the decision level for the decision-makers and the whole of concerned actors. It constitutes a first step to organize a social debate around the risk acceptance, to analyze the feasibility of an inquiry or an epidemiological surveillance or to proportion an activity leading to pollutants emission in natural medium. Several conclusions are brought out: it is justified to estimate a sanitary impact from a sanitary risk excess, especially coming from animal tissue. It is conceivable to go beyond an estimation of the only individual risk and to calculate a number of cases in excess in the concerned population. The working group underlines that the characteristics of the situation are the determining factor to give the type of response to bring. The effective of the population is an important element and a situation has not to be underestimated because of the size at the pretext that the excess calculation leads to a number of cases inferior to one leading to believe that the impact is minor or negligible while the individual probability is high. The sanitary impact, expressed by the number of cancer cases in excess in an exposed population is quantified from the average value of excess of sanitary risk multiplied by the population effective, and expressed with a confidence interval. The sanitary impact can be expressed under the form of a percentage of the population present in the exposure area and goes past the comparison marks usually pointed up. This practice must be cheered. An analysis of uncertainties must be made as often as possible. (N.C.)

  1. Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas.

    Science.gov (United States)

    Peng, Liying; Jiang, Dandan; Wang, Zhenxin; Hua, Lei; Li, Haiyang

    2016-06-01

    Malodorous hydrogen sulfide (H2S) gas often exists in the sewer system and associates with the problems of releasing the dangerous odor to the atmosphere and causing sewer pipe to be corroded. A simple method is in demand for real-time measuring H2S level in the sewer gas. In this paper, an innovated method based on dopant-assisted negative photoionization ion mobility spectrometry (DANP-IMS) with on-line semiconductor cooling inlet was put forward and successfully applied for the real-time measurement of H2S in sewer gas. The influence of moisture was effectively reduced via an on-line cooling method and a non-equilibrium dilution with drift gas. The limits of quantitation for the H2S in ≥60% relative humidity air could be obtained at ≤79.0ng L(-1) with linear ranges of 129-2064ng L(-1). The H2S concentration in a sewer manhole was successfully determined while its product ions were identified by an ion-mobility time-of-fight mass spectrometry. Finally, the correlation between sewer H2S concentration and the daily routines and habits of residents was investigated through hourly or real-time monitoring the variation of sewer H2S in manholes, indicating the power of this DANP-IMS method in assessing the H2S concentration in sewer system. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Determinants of quality, latency, and amount of Stack Overflow answers about recent Android APIs.

    Science.gov (United States)

    Kavaler, David; Filkov, Vladimir

    2018-01-01

    Stack Overflow is a popular crowdsourced question and answer website for programming-related issues. It is an invaluable resource for software developers; on average, questions posted there get answered in minutes to an hour. Questions about well established topics, e.g., the coercion operator in C++, or the difference between canonical and class names in Java, get asked often in one form or another, and answered very quickly. On the other hand, questions on previously unseen or niche topics take a while to get a good answer. This is particularly the case with questions about current updates to or the introduction of new application programming interfaces (APIs). In a hyper-competitive online market, getting good answers to current programming questions sooner could increase the chances of an app getting released and used. So, can developers anyhow, e.g., hasten the speed to good answers to questions about new APIs? Here, we empirically study Stack Overflow questions pertaining to new Android APIs and their associated answers. We contrast the interest in these questions, their answer quality, and timeliness of their answers to questions about old APIs. We find that Stack Overflow answerers in general prioritize with respect to currentness: questions about new APIs do get more answers, but good quality answers take longer. We also find that incentives in terms of question bounties, if used appropriately, can significantly shorten the time and increase answer quality. Interestingly, no operationalization of bounty amount shows significance in our models. In practice, our findings confirm the value of bounties in enhancing expert participation. In addition, they show that the Stack Overflow style of crowdsourcing, for all its glory in providing answers about established programming knowledge, is less effective with new API questions.

  3. Determinants of quality, latency, and amount of Stack Overflow answers about recent Android APIs

    Science.gov (United States)

    Filkov, Vladimir

    2018-01-01

    Stack Overflow is a popular crowdsourced question and answer website for programming-related issues. It is an invaluable resource for software developers; on average, questions posted there get answered in minutes to an hour. Questions about well established topics, e.g., the coercion operator in C++, or the difference between canonical and class names in Java, get asked often in one form or another, and answered very quickly. On the other hand, questions on previously unseen or niche topics take a while to get a good answer. This is particularly the case with questions about current updates to or the introduction of new application programming interfaces (APIs). In a hyper-competitive online market, getting good answers to current programming questions sooner could increase the chances of an app getting released and used. So, can developers anyhow, e.g., hasten the speed to good answers to questions about new APIs? Here, we empirically study Stack Overflow questions pertaining to new Android APIs and their associated answers. We contrast the interest in these questions, their answer quality, and timeliness of their answers to questions about old APIs. We find that Stack Overflow answerers in general prioritize with respect to currentness: questions about new APIs do get more answers, but good quality answers take longer. We also find that incentives in terms of question bounties, if used appropriately, can significantly shorten the time and increase answer quality. Interestingly, no operationalization of bounty amount shows significance in our models. In practice, our findings confirm the value of bounties in enhancing expert participation. In addition, they show that the Stack Overflow style of crowdsourcing, for all its glory in providing answers about established programming knowledge, is less effective with new API questions. PMID:29547620

  4. Sanitary landfill energetic potential analysis: a real case study

    International Nuclear Information System (INIS)

    Desideri, Umberto; Di Maria, Francesco; Leonardi, Daniela; Proietti, Stefania

    2003-01-01

    Waste disposal represents an important problem in developed countries. Many different techniques are available to reduce the amount of waste production and its environmental impact. In most cases, sanitary landfills have been and continue to be one of the most common ways to dispose of urban and industrial wastes. It is well known how landfilling produces an important environmental drawback due to gaseous, liquid and solid emissions that are dangerous for the environment. Landfill biogas emissions contain mainly carbon dioxide and methane. In particular, the methane concentration can be higher than 50% by volume. This means that the calorific value of sanitary landfill biogas can be higher than 18,000 kJ/N m 3 . The utilization of such gas as fuel for electrical and thermal energy production can be an important way to reduce the landfill impact on the environment and represent an easy way to use a renewable energy source. In the following, the amount and composition of the biogas produced in a sanitary landfill situated in central Italy have been analysed. Experimental results have been discussed, and an energetic potential evaluation has been performed

  5. Sanitary landfill energetic potential analysis: a real case study

    Energy Technology Data Exchange (ETDEWEB)

    Desideri, Umberto E-mail: umberto.desideri@unipg.it; Di Maria, Francesco E-mail: fdm@unipg.it; Leonardi, Daniela; Proietti, Stefania

    2003-07-01

    Waste disposal represents an important problem in developed countries. Many different techniques are available to reduce the amount of waste production and its environmental impact. In most cases, sanitary landfills have been and continue to be one of the most common ways to dispose of urban and industrial wastes. It is well known how landfilling produces an important environmental drawback due to gaseous, liquid and solid emissions that are dangerous for the environment. Landfill biogas emissions contain mainly carbon dioxide and methane. In particular, the methane concentration can be higher than 50% by volume. This means that the calorific value of sanitary landfill biogas can be higher than 18,000 kJ/N m{sup 3}. The utilization of such gas as fuel for electrical and thermal energy production can be an important way to reduce the landfill impact on the environment and represent an easy way to use a renewable energy source. In the following, the amount and composition of the biogas produced in a sanitary landfill situated in central Italy have been analysed. Experimental results have been discussed, and an energetic potential evaluation has been performed.

  6. Sewerage overflows put production and fertility of dairy cows at risk

    NARCIS (Netherlands)

    Meijer, G.A.L.; Bree, de J.; Wagenaar, J.A.; Spoelstra, S.F.

    1999-01-01

    More than 50% of the diary farmers in the Netherlands use surface water as the main source of drinking water for their cows during the grazing season. The quality of this water may be affected by discharges from sewerage overflows, but possible effects on health of dairy cows have not been

  7. Evaluation of mechanisms that might control transport of wastewater contaminants in bedrock multi-aquifer systems

    Science.gov (United States)

    Ongoing research has identified infectious human enteric viruses in the Madison, Wisconsin, public supply wells that draw water from a deep, confined sandstone aquifer. These viruses most likely originate from leaking sanitary sewers and are a potential human health risk. Due to a relatively short (...

  8. 25 CFR 169.18 - Tenure of approved right-of-way grants.

    Science.gov (United States)

    2010-04-01

    ..., and public utility water pipelines (including pumping stations and appurtenant facilities), electric... 169.18 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER RIGHTS-OF-WAY OVER... sanitary and storm sewer lines including sewage disposal and treatment plants, water control and use...

  9. Sediment transport modeling in deposited bed sewers: unified form of May's equations using the particle swarm optimization algorithm.

    Science.gov (United States)

    Safari, Mir Jafar Sadegh; Shirzad, Akbar; Mohammadi, Mirali

    2017-08-01

    May proposed two dimensionless parameters of transport (η) and mobility (F s ) for self-cleansing design of sewers with deposited bed condition. The relationships between those two parameters were introduced in conditional form for specific ranges of F s , which makes it difficult to use as a practical tool for sewer design. In this study, using the same experimental data used by May and employing the particle swarm optimization algorithm, a unified equation is recommended based on η and F s . The developed model is compared with original May relationships as well as corresponding models available in the literature. A large amount of data taken from the literature is used for the models' evaluation. The results demonstrate that the developed model in this study is superior to May and other existing models in the literature. Due to the fact that in May's dimensionless parameters more effective variables in the sediment transport process in sewers with deposited bed condition are considered, it is concluded that the revised May equation proposed in this study is a reliable model for sewer design.

  10. Sewer-mining: A water reuse option supporting circular economy, public service provision and entrepreneurship.

    Science.gov (United States)

    Makropoulos, C; Rozos, E; Tsoukalas, I; Plevri, A; Karakatsanis, G; Karagiannidis, L; Makri, E; Lioumis, C; Noutsopoulos, C; Mamais, D; Rippis, C; Lytras, E

    2018-06-15

    Water scarcity, either due to increased urbanisation or climatic variability, has motivated societies to reduce pressure on water resources mainly by reducing water demand. However, this practice alone is not sufficient to guarantee the quality of life that high quality water services underpin, especially within a context of increased urbanisation. As such, the idea of water reuse has been gaining momentum for some time and has recently found a more general context within the idea of the Circular Economy. This paper is set within the context of an ongoing discussion between centralized and decentralized water reuse techniques and the investigation of trade-offs between efficiency and economic viability of reuse at different scales. Specifically, we argue for an intermediate scale of a water reuse option termed 'sewer-mining', which could be considered a reuse scheme at the neighbourhood scale. We suggest that sewer mining (a) provides a feasible alternative reuse option when the geography of the wastewater treatment plant is problematic, (b) relies on mature treatment technologies and (c) presents an opportunity for Small Medium Enterprises (SME) to be involved in the water market, securing environmental, social and economic benefits. To support this argument, we report on a pilot sewer-mining application in Athens, Greece. The pilot, integrates two subsystems: a packaged treatment unit and an information and communications technology (ICT) infrastructure. The paper reports on the pilot's overall performance and critically evaluates the potential of the sewer-mining idea to become a significant piece of the circular economy puzzle for water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. The characteristics of dissolved organic matter (DOM) in storm sewer sediments and the binding interaction with Cu(II) in four typical regions in Beijing, China.

    Science.gov (United States)

    Zhang, Ziyang; Li, Kun; Zhang, Xiaoran; Li, Haiyan

    2017-07-01

    In this work, dissolved organic matter (DOM) was extracted from storm sewer sediments collected in four typical regions (residential, campus, traffic and business regions) in Beijing, China. The basic characteristics of DOM were analyzed by UV-visible spectroscopy (UV-Vis), excitation-emission matrix Fluorescence Spectroscopy and Fourier Transform Infrared Spectroscopy. Furthermore, the complexation between DOM and Cu(II) were investigated. The results showed that there were large amount of aromatic structure in the DOM extracted from storm sewer sediments. The microbial activities had also made a contribution to the DOM in storm sewer sediments. The composition of DOM influenced the complexing capacity of Cu(II) greatly, which may be attributed to the protein-like and humic-like substances in storm sewer sediments. This study demonstrated valuable information on the structure present in the DOM of storm sewer sediments and provided new insight for exploring the relationship between DOM and co-existing heavy metals in storm sewer sediments.

  12. Proces-based modeling of the overflow induced growth of erosional channels

    NARCIS (Netherlands)

    Tuan, T.Q.; Stive, M.J.F.; Verhagen, H.J.; Visser, P.J.

    2008-01-01

    A new process-based approach is introduced for a more efficient computation of the overflow-induced growth of an erosional channel in a noncohesive homogeneous narrow landmass such as the breach growth in a sand-dike. The approach is easy to incorporate in a 1D/2DV morphodynamic model to compute the

  13. City of Richland 300 Area industrial wastewater permit application

    International Nuclear Information System (INIS)

    1995-05-01

    Battelle-Pacific Northwest Labs and Westinghouse Hanford Co. are responsible for operating most of the facilities within the 300 Area; other contractors are also involved. The document gives briefly water/wastewater data: water sources, water usage, water discharge/loss, NPDES permit status, plant sewer outlets size and flow, etc. The document also includes the following attachments: 300 Area building list, Oct. 1993-Oct. 1994 300 Area water balance, waste shipments for CY 1994, complete chemical listing, sanitary sewer sampling results (12/19/94, 1/18/95, 1/15/95), and priority pollutant listings

  14. Sewer slime analysis as a method of spotting heavy metal bearing waste water discharge. Sielhautuntersuchungen zur Einkreisung schwermetallhaltiger Einleitungen

    Energy Technology Data Exchange (ETDEWEB)

    Gutekunst, B.

    1988-01-01

    The sewer slime method, in analogy to sediment analyses, informs about the discharges which are polluted with heavy metals and fed into the public sewage system at specific points, independent of the time of discharge. The sewer slime consisting of bacteria, fungi, organic and inorganic compounds concentrates heavy metals by sedimentation, adsorption and precipitation processes and thus represents a pollution indicator. This study characterizes sewer slimes by means of physical properties and by analysis of the chemical and biological composition. The mechanisms of heavy metal enrichment and reduction under altered environmental conditions are analyzed using the elements Pb, Cd, Cu, Ni and Zn as examples. (RB).

  15. Development of Ukrainian legislation on sanitary protection of water resources in the XX century

    Directory of Open Access Journals (Sweden)

    Ю. А. Чуприна

    2015-05-01

    Full Text Available Problem Setting. The article investigates the formation in Ukraine of legal regulation of the state sanitary control of water, the process of creating of general and special jurisdiction for its implementation, as well as the regulation regime, methods and tools for health protection of waters of different categories. The relevance of this article due to the need to systematize the individual areas of water law, including the protection of water and sanitation of the twentieth century. Analysis of the recent researches and publications. The article devoted to the study of formation in Ukraine of legal regulation of the state sanitary control of water, the process of creating of general and special jurisdiction for its implementation, as well as the regulation regime, methods and tools for health protection of waters of different categories. Paper objective. The relevance of this article due to the need to identify viable methods and instruments of legal regulation of sanitary protection of water during the formation of the main areas of water legislation of Ukraine in the twentieth century. Terms used in the legal protection of water, sanitary water use rules, the bodies of sanitary supervision, the state sanitary inspection. Conclusions. Research in the field of water legislation, and therefore the individual concerned and its protection issues, many scientists were engaged as ecologists and environmentalists. However, the special historical and legal work in a range twentieth century. no. This gap makes it difficult to analyze the current state of affairs in the field of sanitary protection of water. Detection of historical stages of development of water legislation in this area, identifying the main patterns and dynamics of legal regulation of sanitary protection of water in specific historical circumstances will improve the current regime of water protection. The author analyzes the main laws and regulations in the field of materials of

  16. On professional and official requirements to physicians in radiation health by sectoral sanitary and epidemiological stations

    International Nuclear Information System (INIS)

    Usol'tsev, V.I.; Konkina, L.F.; Shishenina, V.I.

    1989-01-01

    Professional and official requirements (POR) to sanitary physician, which deals with radiation hygiene at the sanitary and epidemiologic stations (SES), are considered. These requirements determine minimum of professional skills and abilities in the field of radiation hygiene. Physician should contribute to the improvement of radiation safety and health indices for personnel and population, and in this case, his activity should not impede the further usage of ionizing radiation sources in the national economy. Sanitary physician, dealing with a actain branch of industry, concerning the problems of radiation hygiene should know the principles of deontology, aims and functions of SES establishment and departments in the field of radiation hygiene, legal principles of radiation safety is basic tasks are as follows: 1) State sanitary inspection of sanitary-hygienic measures for the environmental protection and radiation protection of population; 2) organizational and methodological activity; 3) activity in medical civil defense

  17. Tracking artificial sweeteners and pharmaceuticals introduced into urban groundwater by leaking sewer networks.

    Science.gov (United States)

    Wolf, Leif; Zwiener, Christian; Zemann, Moritz

    2012-07-15

    There is little quantitative information on the temporal trends of pharmaceuticals and other emerging compounds, including artificial sweeteners, in urban groundwater and their suitability as tracers to inform urban water management. In this study, pharmaceuticals and artificial sweeteners were monitored over 6 years in a shallow urban groundwater body along with a range of conventional sewage tracers in a network of observation wells that were specifically constructed to assess sewer leakage. Out of the 71 substances screened, 24 were detected at above the analytical detection limit. The most frequent compounds were the iodinated X-ray contrast medium amidotrizoic acid (35.3%), the anticonvulsant carbamazepine (33.3%) and the artificial sweetener acesulfame (27.5%), while all other substances occurred in less than 10% of the screened wells. The results from the group of specifically constructed focus wells within 10 m of defective sewers confirmed sewer leaks as being a major entrance pathway into the groundwater. The spatial distribution of pharmaceuticals and artificial sweeteners corresponds well with predictions by pipeline leakage models, which operate on optical sewer condition monitoring data and hydraulic information. Correlations between the concentrations of carbamazepine, iodinated X-ray contrast media and artificial sweeteners were weak to non-existent. Peak concentrations of up to 4130 ng/l of amidotrizoic acid were found in the groundwater downstream of the local hospital. The analysis of 168 samples for amidotrizoic acid, taken at 5 different occasions, did not show significant temporal trends for the years 2002-2008, despite changed recommendations in the medical usage of amidotrizoic acid. The detailed results show that the current mass balance approaches for urban groundwater bodies must be adapted to reflect the spatially distributed leaks and the variable wastewater composition in addition to the lateral and horizontal groundwater fluxes. Crown

  18. [Sanitary-hygienic assessment of microbial biofertilizer].

    Science.gov (United States)

    Arkhipchenko, N A; Akhtemava, G A; Lebedeva, T V; Voronina, A A; Makhan'kova, T I; Pavlova, M M; Shteĭntsaĭg, T A

    1991-10-01

    Biological treatment of sewage from pig-breeding complexes allowed to produce microbial biomass and primary sediments. The mixture of these components (1:1) after rendering harmless and drying out become the high effective biofertilizer. The results of chronic experiment on sanitary status of soil (microbial and helminthological indexes) under this biofertilizer usage are discussed, and the harmlessness of it is demonstrated.

  19. Water sensitive urban design retrofits in Copenhagen - 40% to the sewer, 60% to the city

    DEFF Research Database (Denmark)

    Fryd, O.; Backhaus, Antje; Birch, Heidi

    2013-01-01

    Water Sensitive Urban Design (WSUD) is emerging in Denmark. This interdisciplinary desk study investigated the options for WSUD retrofitting in a 15 km(2) combined sewer catchment area in Copenhagen. The study was developed in collaboration with the City of Copenhagen and its water utility......, neighbourhoods located near low-lying streams and public parks are disconnected from the sewer system and the sloping terrain is utilised to convey runoff. Fourth, the promotion of coherent blue and green wedges in the city is linked with WSUD retrofits and urban climate-proofing. Fifth, WSUD is implemented...

  20. Occurrence of enrofloxacin in overflows from animal lot and residential sewage lagoons and a receiving-stream

    Directory of Open Access Journals (Sweden)

    Abua Ikem

    2017-10-01

    Full Text Available Enrofloxacin (ENRO, a fluoroquinolone, was quantified in overflows from an animal lot and residential sewage lagoons and in a receiving-stream (Gans Creek. The concentrations of ENRO in samples was determined by high-performance liquid chromatography − tandem mass spectrometry. In total, ninety samples including duplicates were analyzed during several monthly sampling campaigns. The samples collected represented the residential sewage lagoon overflow (RLO, animal lot lagoon overflow (ALLO, the combined overflows (RLO and ALLO, and Gans Creek (upstream, midstream and downstream positions. The frequency of detection of ENRO was 90% for RLO and 100% for both ALLO and Gans Creek. The highest concentration of ENRO (0.44 μg/L was found in ALLO sample collected during high precipitation. ENRO levels found in RLO samples ranged from < LOQ to 259 ng/L and the highest value observed also coincided with high flow. The levels of ENRO found in Gans Creek ranged from 17–216 ng/L. A preliminary ecotoxicological assessment was conducted through calculation of the risk quotients (RQs for organisms based on the ratio of the measured environmental concentrations in this study to the predicted-no-effect-concentrations (acute and chronic effect data. From the RQs, high risks were observed for Microcystis aeruginosa (cyanobacteria; RQ = 4.4; Anabaena flosaquae (cyanobacteria; RQ = 1.3; and Lemna minor (aquatic vascular plant; RQ = 2.0. The long-term effects of mixtures of PHCs on Gans Creek watershed are probable. Keywords: Environmental science, Pharmaceutical chemistry, Ecology

  1. A condition for the overflow stability of second-order digital filters that is satisfied by all scaled state-space structures using saturation

    NARCIS (Netherlands)

    Ritzerfeld, J.H.F.

    1989-01-01

    A set of conditions is derived that ensures overflow stability of second-order digital filters for different classes of overflow arithmetics, involving only the elements of the state-transition matrix. The well-known arithmetic saturation, zeroing, and two's-complement lead to different stability

  2. Kanalnetz- und Kläranlagenzuflusssteuerung am Beispiel des Einzugsgebiets Wilhelmshaven

    DEFF Research Database (Denmark)

    Seggelke, Katja; Beeneken, Thomas; Fuchs, Lothar

    2013-01-01

    in overall stormwater overflow volumes at the sensitive sewage disposal point only thanks to the implementation of the control system. Moreover, the safe operation of the wastewater treatment plant can be guaranteed by simple means without significantly increasing stormwater overflow discharges. Currently......In the catchment area of the Wilhelmshaven wastewater treatment plant, an integrated, fuzzy-based control system has been in place for more than a year now. The system’s essential elements are a sewer network control system to reduce stormwater overflow events and volumes at a sensitive sewage...... disposal point as well as the control of the wastewater treatment plant’s inflow as a function of measurement values during the treatment process in order to avoid critical load conditions. The accompanying monitoring shows that operating experiences are positive and it confirms a more than 25 % reduction...

  3. Peracetic Acid as a Green Disinfectant for Combined Sewer Overflows

    Science.gov (United States)

    This cooperative research and development agreement between U.S. EPA, Solvay, MSDGC, and CB&I is evaluating the potential of PAA for disinfection of Muddy Creek CSO wastewater and comparing that with sodium hypochlorite disinfection. This presentation will document the effectiven...

  4. Suitable flow pattern increases the removal efficiency of nitrogen in gravity sewers: a suitable anoxic and aerobic environment in biofilms.

    Science.gov (United States)

    He, Qiang; Yin, Feixian; Li, Hong; Wang, Yinliang; Xu, Jingwei; Ai, Hainan

    2018-03-25

    The sewers have the function of carbon removal, which has been proven. But if the effect of nitrogen removal can be enhanced at the same time of carbon removal, it can lay a foundation for the realization of "sewer's working as a reactor." This paper investigated the effects of shear stress and C/N ratio on nitrogen removal through biofilms on the sewer inner wall and nitrogen transfer. The main conclusions are as follows: (1) nitrogen could be partially removed in sewers after a series of reactions; (2) the anaerobic, anoxic, aerobic environment and some bacteria related to nitrogen metabolism, which exist in the biofilm, promote the nitrification and denitrification; (3) a total of 722 functional genes involved in nitrogen metabolism were detected in the biofilm (C/N ratio of 10, shear stress of 1.4 Pa), accounting for 0.67% of all genes, and the functional genes related to denitrification were dominant. Graphical abstract ᅟ.

  5. [Street food: analysis of hygienic and sanitary conditions of food handlers].

    Science.gov (United States)

    de Souza, Giovanna Carbonera; dos Santos, Celso Tadeu Barbosa; Andrade, Anderson Assunção; Alves, Luciene

    2015-08-01

    The consumption of street food is an economical and practical alternative for the population. However, concerns regarding the safety of these foods are increasing. Thus, this study aimed to analyze the hygienic and sanitary conditions of the street food trade in Uberaba in the State of Minas Gerais. For this purpose, 30 street vending sites were evaluated using a structured questionnaire and microbiological analysis of food handlers' hands and food contact recipients and surfaces. The findings showed low adequacy of street food regarding hand hygiene and food contact surfaces. With respect to surfaces, the results for mesophilic aerobic microorganisms revealed that only 23.3% had satisfactory sanitary conditions. The level of contamination of hands by fecal thermotolerant coliforms and/or Coagulase positive Staphylococci was unsatisfactory in approximately 47% of food handlers. The conclusion drawn is that the hygienic and sanitary conditions of food handlers in Uberaba are poor. It is therefore necessary to adopt effective and permanent training programs on food safety for food handlers urgently.

  6. Pollution loads in urban runoff and sanitary wastewater.

    Science.gov (United States)

    Taebi, Amir; Droste, Ronald L

    2004-07-05

    While more attention has been paid in recent years to urban point source pollution control through the establishment of wastewater treatment plants in many developing countries, no considerable planning nor any serious measures have been taken to control urban non-point source pollution (urban stormwater runoff). The present study is a screening analysis to investigate the pollution loads in urban runoff compared to point source loads as a first prerequisite for planning and management of receiving water quality. To compare pollutant loads from point and non-point urban sources, the pollutant load is expressed as the weight of pollutant per hectare area per year (kg/ha.year). Unit loads were estimated in stormwater runoff, raw sanitary wastewater and secondary treatment effluents in Isfahan, Iran. Results indicate that the annual pollution load in urban runoff is lower than the annual pollution load in sanitary wastewater in areas with low precipitation but it is higher in areas with high precipitation. Two options, namely, advanced treatment (in lieu of secondary treatment) of sanitary wastewater and urban runoff quality control systems (such as detention ponds) were investigated as controlling systems for pollution discharges into receiving waters. The results revealed that for Isfahan, as a low precipitation urban area, advanced treatment is a more suitable option, but for high precipitation urban areas, urban surface runoff quality control installations were more effective for suspended solids and oxygen-demanding matter controls, and that advanced treatment is the more effective option for nutrient control.

  7. Pollution loads in urban runoff and sanitary wastewater

    International Nuclear Information System (INIS)

    Taebi, Amir; Droste, Ronald L.

    2004-01-01

    While more attention has been paid in recent years to urban point source pollution control through the establishment of wastewater treatment plants in many developing countries, no considerable planning nor any serious measures have been taken to control urban non-point source pollution (urban stormwater runoff). The present study is a screening analysis to investigate the pollution loads in urban runoff compared to point source loads as a first prerequisite for planning and management of receiving water quality. To compare pollutant loads from point and non-point urban sources, the pollutant load is expressed as the weight of pollutant per hectare area per year (kg/ha·year). Unit loads were estimated in stormwater runoff, raw sanitary wastewater and secondary treatment effluents in Isfahan, Iran. Results indicate that the annual pollution load in urban runoff is lower than the annual pollution load in sanitary wastewater in areas with low precipitation but it is higher in areas with high precipitation. Two options, namely, advanced treatment (in lieu of secondary treatment) of sanitary wastewater and urban runoff quality control systems (such as detention ponds) were investigated as controlling systems for pollution discharges into receiving waters. The results revealed that for Isfahan, as a low precipitation urban area, advanced treatment is a more suitable option, but for high precipitation urban areas, urban surface runoff quality control installations were more effective for suspended solids and oxygen-demanding matter controls, and that advanced treatment is the more effective option for nutrient control

  8. Sulfide-iron interactions in domestic wastewater from a gravity sewer

    NARCIS (Netherlands)

    Nielsen, A.H.; Lens, P.N.L.; Vollertsen, J.; Hvitved-Jacobsen, Th.

    2005-01-01

    Interactions between iron and sulfide in domestic wastewater from a gravity sewer were investigated with particular emphasis on redox cycling of iron and iron sulfide formation. The concentration ranges of iron and total sulfide in the experiments were 0.4-5.4 mg Fe L-1 and 0-5.1 mg S L-1,

  9. The Importance of Lake Overflow Floods for Early Martian Landscape Evolution: Insights From Licus Vallis

    Science.gov (United States)

    Goudge, T. A.; Fassett, C. I.

    2017-01-01

    Open-basin lake outlet valleys are incised when water breaches the basin-confining topography and overflows. Outlet valleys record this flooding event and provide insight into how the lake and surrounding terrain evolved over time. Here we present a study of the paleolake outlet Licus Vallis, a >350 km long, >2 km wide, >100 m deep valley that heads at the outlet breach of an approx.30 km diameter impact crater. Multiple geomorphic features of this valley system suggest it records a more complex evolution than formation from a single lake overflow flood. This provides unique insight into the paleohydrology of lakes on early Mars, as we can make inferences beyond the most recent phase of activity..

  10. Overflow type sodium sampler for FBTR circuits

    International Nuclear Information System (INIS)

    Muralidaran, P.; Ganesan, V.; Chandran, K.; Periaswami, G.

    1996-01-01

    Obtaining a representative sample is crucial for getting reliable results in sodium analysis. Sampling liquid sodium reliability is complicated since impurities segregate while cooling. Selective sorption of certain elements calls for use of different crucible materials for various sodium impurities. Sampling methods currently in use such as flow through sampling and dip sampling are not the proper methods as they can not take care of the above problems. An overflow type sampler where the entire sample contained in a crucible can be used for analysis thus obviating problems due to segregation has been developed for use in Fast Breeder Test Reactor (FBTR). This report describes the construction and operation of this sampler. (author)

  11. The sanitary officer: first aid coordinator on EDF nuclear power plant

    International Nuclear Information System (INIS)

    Masson, A.

    2000-01-01

    The internal organisation for first aid to the injured in case of an accident on E.D.F. nuclear power plant calls for the immediate assistance of a first aid team, consisting of five workers, under the direction of a principal first aid officer; one of the first aid workers, the sanitary officer who instructs the first aid workers intervention awaiting the arrival of an external medical. When the 'Sanitary on-site Emergency Plan' was up' dated, twenty medical doctors and seventy members of staff from five different sites were questioned as to the function of the sanitary officer. The conclusions revealed a notable difference of training amongst the different sites, and concerning first aid organisation, difference of priority of actions, extent of their participation once the medical team arrives and their participation in case of decontamination treatment. The medical doctors and staff lay a particular stress on importance of defining on a national scale the limits of role and responsibilities of the sanitary officer and establish a more specific training in this field, consequently motivating commitment and professionalism involvement. There is a great difference between the training and coaching of the first aid assistance and fire protection teams. To conclude, we propose that the first aid officer be known as first aid coordinator and the qualification of 'Certificat de Formation aux Premiers Secours en Equipe' in compliance with the current legislation together with a specific nuclear module and they should undergo regular on-site drills. (author)

  12. Demonstration of an Innovative Large-Diameter Sewer Rehabilitation Technology in Houston, Texas

    Science.gov (United States)

    While sewer renewal technologies currently being used for the repair, replacement and/or rehabilitation of deteriorating wastewater collection systems are generally effective, there is still room for improvement of existing technologies and for the development of new technologies...

  13. Food Safety and Sanitary Practices of Selected Hotels in Batangas Province, Philippines: Basis of Proposed Enhancement Measures

    Directory of Open Access Journals (Sweden)

    April M. Perez

    2017-02-01

    Full Text Available This study assessed the extent of food safety and sanitary practices of selected hotels in Batangas province as basis of proposed enhancement measures. The study utilized descriptive method to describe food safety and sanitary practices of selected hotels in Batangas province with a total of 8 hotels (256 respondents. Purposive sampling was used in the study. The questionnaires were designed using the provision of the Sanitation Code of the Philippines, validated and finalized to come up with legitimate results. The study showed that there were eight (8 hotel respondents classified as two, three, four star with considerable years of experience and adequate number of employees. The hotels demonstrated the food safety and sanitary practices always in the areas of restaurant, bar service, catering and banquet and room service. The significant pair-wise comparison for restaurant, bar service, catering and banquet and room service shows that 2 star hotels greatly differs. The researcher recommends that the management should maintain high standard of food safety and sanitary practices among its staff, upgrade the food safety and sanitary practices for food safety accreditation, continuous training of the hotel managers/employees on food safety and sanitary practices.

  14. Anaerobic Digestion and Combined Heat and Power Study

    Energy Technology Data Exchange (ETDEWEB)

    Frank J. Hartz

    2011-12-30

    One of the underlying objectives of this study is to recover the untapped energy in wastewater biomass. Some national statistics worth considering include: (1) 5% of the electrical energy demand in the US is used to treat municipal wastewater; (2) This carbon rich wastewater is an untapped energy resource; (3) Only 10% of wastewater treatment plants (>5mgd) recover energy; (4) Wastewater treatment plants have the potential to produce > 575 MW of energy nationwide; and (5) Wastewater treatment plants have the potential to capture an additional 175 MW of energy from waste Fats, Oils and Grease. The WSSC conducted this study to determine the feasibility of utilizing anaerobic digestion and combined heat and power (AD/CHP) and/or biosolids gasification and drying facilities to produce and utilize renewable digester biogas. Digester gas is considered a renewable energy source and can be used in place of fossil fuels to reduce greenhouse gas emissions. The project focus includes: (1) Converting wastewater Biomass to Electricity; (2) Using innovative technologies to Maximize Energy Recovery; and (3) Enhancing the Environment by reducing nutrient load to waterways (Chesapeake Bay), Sanitary Sewer Overflows (by reducing FOG in sewers) and Greenhouse Gas Emissions. The study consisted of these four tasks: (1) Technology screening and alternative shortlisting, answering the question 'what are the most viable and cost effective technical approaches by which to recover and reuse energy from biosolids while reducing disposal volume?'; (2) Energy recovery and disposal reduction potential verification, answering the question 'how much energy can be recovered from biosolids?'; (3) Economic environmental and community benefit analysis, answering the question 'what are the potential economic, environmental and community benefits/impacts of each approach?'; and (4) Recommend the best plan and develop a concept design.

  15. Using EPA Tools and Data Services to Inform Changes to Design Storm Definitions for Wastewater Utilities based on Climate Model Projections

    Science.gov (United States)

    Tryby, M.; Fries, J. S.; Baranowski, C.

    2014-12-01

    Extreme precipitation events can cause significant impacts to drinking water and wastewater utilities, including facility damage, water quality impacts, service interruptions and potential risks to human health and the environment due to localized flooding and combined sewer overflows (CSOs). These impacts will become more pronounced with the projected increases in frequency and intensity of extreme precipitation events due to climate change. To model the impacts of extreme precipitation events, wastewater utilities often develop Intensity, Duration, and Frequency (IDF) rainfall curves and "design storms" for use in the U.S. Environmental Protection Agency's (EPA) Storm Water Management Model (SWMM). Wastewater utilities use SWMM for planning, analysis, and facility design related to stormwater runoff, combined and sanitary sewers, and other drainage systems in urban and non-urban areas. SWMM tracks (1) the quantity and quality of runoff made within each sub-catchment; and (2) the flow rate, flow depth, and quality of water in each pipe and channel during a simulation period made up of multiple time steps. In its current format, EPA SWMM does not consider climate change projection data. Climate change may affect the relationship between intensity, duration, and frequency described by past rainfall events. Therefore, EPA is integrating climate projection data available in the Climate Resilience Evaluation and Awareness Tool (CREAT) into SWMM. CREAT is a climate risk assessment tool for utilities that provides downscaled climate change projection data for changes in the amount of rainfall in a 24-hour period for various extreme precipitation events (e.g., from 5-year to 100-year storm events). Incorporating climate change projections into SWMM will provide wastewater utilities with more comprehensive data they can use in planning for future storm events, thereby reducing the impacts to the utility and customers served from flooding and stormwater issues.

  16. Coupling a continuous watershed-scale microbial fate and transport model with a stochastic dose-response model to estimate risk of illness in an urban watershed.

    Science.gov (United States)

    Liao, Hehuan; Krometis, Leigh-Anne H; Kline, Karen

    2016-05-01

    Within the United States, elevated levels of fecal indicator bacteria (FIB) remain the leading cause of surface water-quality impairments requiring formal remediation plans under the federal Clean Water Act's Total Maximum Daily Load (TMDL) program. The sufficiency of compliance with numerical FIB criteria as the targeted endpoint of TMDL remediation plans may be questionable given poor correlations between FIB and pathogenic microorganisms and varying degrees of risk associated with exposure to different fecal pollution sources (e.g. human vs animal). The present study linked a watershed-scale FIB fate and transport model with a dose-response model to continuously predict human health risks via quantitative microbial risk assessment (QMRA), for comparison to regulatory benchmarks. This process permitted comparison of risks associated with different fecal pollution sources in an impaired urban watershed in order to identify remediation priorities. Results indicate that total human illness risks were consistently higher than the regulatory benchmark of 36 illnesses/1000 people for the study watershed, even when the predicted FIB levels were in compliance with the Escherichia coli geometric mean standard of 126CFU/100mL. Sanitary sewer overflows were associated with the greatest risk of illness. This is of particular concern, given increasing indications that sewer leakage is ubiquitous in urban areas, yet not typically fully accounted for during TMDL development. Uncertainty analysis suggested the accuracy of risk estimates would be improved by more detailed knowledge of site-specific pathogen presence and densities. While previous applications of the QMRA process to impaired waterways have mostly focused on single storm events or hypothetical situations, the continuous modeling framework presented in this study could be integrated into long-term water quality management planning, especially the United States' TMDL program, providing greater clarity to watershed

  17. Overflow Characteristic of Cylindrical Shape Crest Weirs Over Horizontal Bed

    Directory of Open Access Journals (Sweden)

    Emad4 AbdulGabbar

    2013-05-01

    Full Text Available The most common types of weirs are the broad-crested weir, the sharp-crested weir, the circular crested weir and the ogee crested weir. Advantages of the cylindrical weir shape include the stable overflow pattern, the ease to pass floating debris, the simplicity of design compared to ogee crest design and the associated lower costs. In present study, it was investigated the overflow characteristics of circular weirs in laboratory for various cylinder radii of three sizes (11.4, 9.0, 6.3 cm, and the models fixed on the channel bed vertically to the direction of flow. The result shows that the increase in the ratio of head to weir radius ratio (Hw/R value causes an increase in discharge coefficient (Cd value for the same height of weir. It was observed that the cylinder size (i.e. radius of cylindrical weir (R has an effect on the (Cd. The flow magnification factor (qw/qs increases with an increase in (Hw/R value and values of (qw/qs were always higher than one for all values of (Hw/R, this means that weirs of cylindrical shape performed better than those of sharp crest for any value of weir radius tested in this study.

  18. Entrainment and mixing in a laboratory model of oceanic overflow

    OpenAIRE

    Odier , Philippe; Chen , Jun; Ecke , Robert

    2014-01-01

    International audience; We present experimental measurements of a wall-bounded gravity current, motivated by characterizing natural gravity currents such as oceanic overflows. We use particle image velocimetry and planar laser-induced fluorescence to simultaneously measure the velocity and density fields as they evolve downstream of the initial injection from a turbulent channel flow onto a plane inclined at 10 degrees with respect to horizontal. The turbulence level of the input flow is cont...

  19. Half saturation constants for nitrate and nitrite by in-sewer anoxic transformations of wastewater organic matter

    DEFF Research Database (Denmark)

    Abdul-Talib, Suhaimi; Hvitved-Jacobsen, Thorkild; Vollertsen, Jes

    2001-01-01

     significant breakthrough and progress have been made in the study of the kinetics of microbial transformation in sewers under aerobic and under changing aerobic/anaerobic conditions. Fundamental knowledge on anoxic kinetics of wastewater is still lacking, so it is not now possible to apply...... an integrated approach to municipal wastewater treatment incorporating sewer networks as a bio-chemical reactor. This paper presents the results of studies on determining half saturation constants for nitrate, KNO3, and nitrite, KNO2, in raw wastewater. The average values of KNO3 and KNO2, determined from...

  20. Phase and Micro-Structural Characterization of Sanitary-Ware Fired at Different Temperature

    OpenAIRE

    ATHER HASSAN; YASEEN IQBAL; SYED ZAFAR ILYAS

    2017-01-01

    The three main ingredients of sanitary-ware are clay, feldspar and quartz. This ware is being widely used and has therefore, attracted the attention of researchers from time to time. Consequently, it has been extensively investigated. The present study describes the phase and micro-structural analysis of sanitary-ware samples collected from local (Durr Ceramics Peshawar) industry. XRD (X-Ray Diffraction) of samples fired at 1100oC reveals the presence of ? ? ? ? ?-quartz and primary mullite o...