WorldWideScience

Sample records for sandwich elisa methods

  1. Hyperglucagonaemia analysed by glucagon sandwich ELISA

    DEFF Research Database (Denmark)

    Albrechtsen, Nicolai Jacob Wewer; Hartmann, Bolette; Veedfald, Simon

    2014-01-01

    the extent to which the hyperglucagonaemia measured in clinical samples was caused by authentic glucagon. METHODS: We examined the performance of three commercial glucagon 'sandwich' ELISAs. The ELISA with the best overall performance was selected to compare glucagon measurements in clinical samples...... sensitivity for glucagon in plasma (>10-20 pmol/l). Thus, only the third assay was suitable for measuring glucagon concentrations in clinical samples. The ELISA and RIA measured similar glucagon levels in healthy individuals. Measurements of samples from individuals with abnormally high (type 2 diabetes...... or obese) or very elevated (post vagotomy with pyloroplasty, post-RYGB) glucagon levels were also similar in both assays. However, glucagon levels in participants with ESRD were much lower when measured by ELISA than by RIA, indicating that the apparent hyperglucagonaemia is not caused by fully processed...

  2. ELISA with double antigen sandwich for screening specific serum anti-TP antibody in blood donors

    International Nuclear Information System (INIS)

    Wang Yiqing; Shi Zhixu

    2002-01-01

    Objective: To select a sensitive and specific laboratory examination suitable for screening serum anti-TP antibody in blood donors. Methods: The serum anti-TP antibody in 11271 blood donors were detected using ELISA with double antigen sandwich and the outcomes were compared with those using RPR assay. The conflicting specimen were confirmed by repeating the test with TPHA assay. Results: The positive rates of serum anti-TP antibody by ELISA with double antigen sandwich and RPR was 0.36% (41/11271) and 0.26% (29/11271), respectively. The coincidence of the detecting outcomes by ELISA with double antigen sandwich and RPR with TPHA was 97.5% (40/41) and 63.41%(26/41) respectively. Conclusion: Compared with RPR assay, ELISA with double antigen sandwich has higher sensibility and specificity for screening serum anti-TP antibody in blood donors

  3. Evaluation of monoclonal antibody-based sandwich direct ELISA (MSD-ELISA) for antigen detection of foot-and-mouth disease virus using clinical samples.

    Science.gov (United States)

    Morioka, Kazuki; Fukai, Katsuhiko; Sakamoto, Kenichi; Yoshida, Kazuo; Kanno, Toru

    2014-01-01

    A monoclonal antibody-based sandwich direct ELISA (MSD-ELISA) method was previously developed for foot-and-mouth disease (FMD) viral antigen detection. Here we evaluated the sensitivity and specificity of two FMD viral antigen detection MSD-ELISAs and compared them with conventional indirect sandwich (IS)-ELISA. The MSD-ELISAs were able to detect the antigen in saliva samples of experimentally-infected pigs for a longer term compared to the IS-ELISA. We also used 178 RT-PCR-positive field samples from cattle and pigs affected by the 2010 type-O FMD outbreak in Japan, and we found that the sensitivities of both MSD-ELISAs were about 7 times higher than that of the IS-ELISA against each sample (P<0.01). In terms of the FMD-positive farm detection rate, the sensitivities of the MSD-ELISAs were about 6 times higher than that of the IS-ELISA against each farm (P<0.01). Although it is necessary to conduct further validation study using the other virus strains, MSD-ELISAs could be appropriate as a method to replace IS-ELISA for FMD antigen detection.

  4. Development of monoclonal antibody-based sandwich ELISA for detection of dextran.

    Science.gov (United States)

    Wang, Sheng-Yu; Li, Zhe; Wang, Xian-Jiang; Lv, Sha; Yang, Yun; Zeng, Lian-Qiang; Luo, Fang-Hong; Yan, Jiang-Hua; Liang, Da-Feng

    2014-10-01

    Dextran as anti-nutritional factor is usually a result of bacteria activity and has associated serial problems during the process stream in the sugar industry and in medical therapy. A sensitive method is expected to detect dextran quantitatively. Here we generated four monoclonal antibodies (MAbs) against dextran using dextran T40 conjugated with bovine serum albumin (BSA) as immunogen in our lab following hybridoma protocol. Through pairwise, an MAb named D24 was determined to be conjugated with horseradish peroxidase (HRP) and was used in the establishment of a sensitive sandwich enzyme-linked immunosorbent assay (ELISA) method for determination of dextran, in which MAb D9 was chosen as a capture antibody. The detection limit and working scope of the developed sandwich ELISA method were 3.9 ng/mL and 7.8-500 ng/mL with a correlation coefficient of 0.9909. In addition, the cross-reaction assay demonstrated that the method possessed high specificity with no significant cross-reaction with dextran-related substances, and the recovery rate ranged from 96.35 to 102.00%, with coefficient of variation ranging from 1.58 to 6.94%. These results indicated that we developed a detection system of MAb-based sandwich ELISA to measure dextran and this system should be a potential tool to determine dextran levels.

  5. [A double antibody sandwich ELISA based assay for titration of severe fever with thrombocytopenia syndrome virus].

    Science.gov (United States)

    Liu, Lin; Zhang, Quan-Fu; Li, Chuan; Li, Jian-Dong; Jiang, Xiao-Lin; Zhang, Fu-Shun; Wu, Wei; Liang, Mi-Fang; Li, De-Xin

    2013-06-01

    To develop an assay for titration of severe fever with thrombocytopenia syndrome virus (SFTSV) based on double antibody sandwich ELISA. A double antibody sandwich ELISA was developed for detection of SFTSV based on SFTSV nucleocapsid (N) protein specific poly- and monoclonal antibodies, procedures were optimized and evaluated. This ELISA based titration assay was compared with fluorescence assasy and plaque assay based titration method. The results suggested that the titers obtained by ELISA based method are consistent with those obtained by IFA based method (R = 0.999) and the plaque assay titration method (R = 0.949). The novel ELISA based titration method with high sensitivity and specificity is easy to manage and perform, and can overcome the subjectivity associated with result determination of the fluorescence assay and plaque assay based methods. The novel ELISA based titration method can also be applied to high throughput detection.

  6. Evaluation of monoclonal antibody-based sandwich direct ELISA (MSD-ELISA for antigen detection of foot-and-mouth disease virus using clinical samples.

    Directory of Open Access Journals (Sweden)

    Kazuki Morioka

    Full Text Available A monoclonal antibody-based sandwich direct ELISA (MSD-ELISA method was previously developed for foot-and-mouth disease (FMD viral antigen detection. Here we evaluated the sensitivity and specificity of two FMD viral antigen detection MSD-ELISAs and compared them with conventional indirect sandwich (IS-ELISA. The MSD-ELISAs were able to detect the antigen in saliva samples of experimentally-infected pigs for a longer term compared to the IS-ELISA. We also used 178 RT-PCR-positive field samples from cattle and pigs affected by the 2010 type-O FMD outbreak in Japan, and we found that the sensitivities of both MSD-ELISAs were about 7 times higher than that of the IS-ELISA against each sample (P<0.01. In terms of the FMD-positive farm detection rate, the sensitivities of the MSD-ELISAs were about 6 times higher than that of the IS-ELISA against each farm (P<0.01. Although it is necessary to conduct further validation study using the other virus strains, MSD-ELISAs could be appropriate as a method to replace IS-ELISA for FMD antigen detection.

  7. A sandwich ELISA for measurement of the primary glucagon-like peptide-1 metabolite

    DEFF Research Database (Denmark)

    Wewer Albrechtsen, Nicolai J; Asmar, Ali; Jensen, Frederik

    2017-01-01

    developed a sandwich ELISA recognizing both GLP-1 9-36NH2 and nonamidated GLP-1 9-37. The ELISA was validated using analytical assay validation guidelines and by comparing it to a subtraction-based method, hitherto employed for estimation of GLP-1 9-36NH2 Its accuracy was evaluated from measurements...

  8. Sandwich ELISA for quantitative detection of human collagen prolyl 4-hydroxylase

    Directory of Open Access Journals (Sweden)

    Myllyharju Johanna

    2010-06-01

    Full Text Available Abstract Background We describe a method for specific, quantitative and quick detection of human collagen prolyl 4-hydroxylase (C-P4H, the key enzyme for collagen prolyl-4 hydroxylation, in crude samples based on a sandwich ELISA principle. The method is relevant to active C-P4H level monitoring during recombinant C-P4H and collagen production in different expression systems. The assay proves to be specific for the active C-P4H α2β2 tetramer due to the use of antibodies against its both subunits. Thus in keeping with the method C-P4H is captured by coupled to an anti-α subunit antibody magnetic beads and an anti-β subunit antibody binds to the PDI/β subunit of the protein. Then the following holoenzyme detection is accomplished by a goat anti-rabbit IgG labeled with alkaline phosphatase which AP catalyzes the reaction of a substrate transformation with fluorescent signal generation. Results We applied an experimental design approach for the optimization of the antibody concentrations used in the sandwich ELISA. The assay sensitivity was 0.1 ng of C-P4H. The method was utilized for the analysis of C-P4H accumulation in crude cell extracts of E. coli overexpressing C-P4H. The sandwich ELISA signals obtained demonstrated a very good correlation with the detected protein activity levels measured with the standard radioactive assay. The developed assay was applied to optimize C-P4H production in E. coli Origami in a system where the C-P4H subunits expression acted under control by different promoters. The experiments performed in a shake flask fed-batch system (EnBase® verified earlier observations that cell density and oxygen supply are critical factors for the use of the inducer anhydrotetracycline and thus for the soluble C-P4H yield. Conclusions Here we show an example of sandwich ELISA usage for quantifying multimeric proteins. The method was developed for monitoring the amount of recombinant C-P4H tetramer in crude E. coli extracts. Due

  9. Development of indirect sandwich ELISA for determination of excretory-secretory antigens of Fasciola hepatica

    Directory of Open Access Journals (Sweden)

    Libertad Alzamora-Gonzales

    2016-05-01

    Full Text Available Fasciolosis is a cosmopolitan parasitosis medical-veterinary importance caused by Fasciola hepatica, which affects sheep, goats and cattle; and it affects man accidentally causing an epidemic-endemic infection difficult to diagnose. The aim was to develop an indirect sandwich ELISA with 3 antibodies for detecting excretory-secretory antigens of Fasciola hepatica (ESFh. For the development of indirect sandwich ELISA were used, as capture antibody, mouse polyclonal antibodies anti ESFh and polyclonal antibodies rabbit anti-ESFh as detection antibody, at the concentrations of 10 and 5 µg/mL respectively. The conjugate used was mouse monoclonal anti- total immunoglobulins rabbit linked to peroxidase (1/1000. Were analized 31 sheep fecal samples, and the results were compared with those obtained by direct coproparasitological examination (DC and counterimmunoelectrophoresis (CIEP. The detection limit obtained for indirect sandwich ELISA was 100 ng/mL. The test had a 100% sensitivity, 96.6% specificity, positive and negative predictive values of 50% and 96.6% respectively, in relation to DC test. Comparing with CIEP the specificity obtained for indirect sandwich ELISA was 93.5% and a negative predictive value of 100%. We concluded that indirect sandwich ELISA designed is able to detect metabolic antigens in ovine feces samples and can be used for Fasciola hepatica diagnosis.

  10. Protein unfolding allows use of commercial antibodies in an apolipoprotein M sandwich ELISA

    DEFF Research Database (Denmark)

    Bosteen, Markus Høybye; Dahlbäck, Björn; Nielsen, Lars Bo

    2015-01-01

    that specifically recognizes human apoM in plasma using commercially available reagents. Commercial apoM antibodies were screened for compatibility in a sandwich ELISA-based assay. One optimal pair of antibodies was chosen, and sample preparation, buffers, and incubation times were optimized to generate a simple...... and reproducible method. Validation and comparison to a previously described ELISA for apoM confirmed that the assay displays a high degree of sensitivity, specificity, and precision. Our results show that commercially available antibodies can be used to accurately measure human plasma apoM. This method can...

  11. Development and evaluation of a sandwich ELISA for quantification of the 20S proteasome in human plasma

    DEFF Research Database (Denmark)

    Dutaud, Dominique; Aubry, Laurent; Henry, Laurent

    2002-01-01

    Because quantification of the 20S proteasome by functional activity measurements is difficult and inaccurate, we have developed an indirect sandwich enzyme-linked immunosorbent assays (ELISA) for quantification of the 20S proteasome in human plasma. This sandwich ELISA uses a combination...

  12. Immunodiagnosis of Fasciola gigantica Infection Using Monoclonal Antibody-Based Sandwich ELISA and Immunochromatographic Assay for Detection of Circulating Cathepsin L1 Protease

    Science.gov (United States)

    Anuracpreeda, Panat; Chawengkirttikul, Runglawan; Sobhon, Prasert

    2016-01-01

    Background Tropical fasciolosis caused by Fasciola gigantica infection is one of the major diseases infecting ruminants in the tropical regions of Africa and Asia including Thailand. Parasitological diagnosis of fasciolosis is often unreliable and possesses low sensitivity. Therefore, the detection of circulating parasite antigens is thought to be a better alternative for diagnosis of fasciolosis, as it reflects the real parasite burden. Methods In this study, we have produced a monoclonal antibody (MoAb) against recombinant F. gigantica cathepsin L1 (rFgCatL1), and developed both sandwich enzyme-linked immunosorbent assay (sandwich ELISA) and immunochromatographic (IC) test for rapid detection of circulating cathepsin L1 protease (CatL1) in the sera from mice experimentally and cattle naturally infected with Fasciola gigantica. MoAb 4E3 and biotinylated rabbit anti-recombinant CatL1 antibody were selected due to their high reactivities and specificities. Results The lower detection limits of sandwich ELISA and IC test were 3 pg/ml and 0.256 ng/ml, respectively. Sandwich ELISA and IC test could detect F. gigantica infection from day 1 to 35 post infection. In experimental mice, the sensitivity, specificity and accuracy were 95%, 100% and 98.6% (for sandwich ELISA), and 93%, 100% and 98.2% (for IC test), while in natural cattle they were 98.3%, 100% and 99.5% (for sandwich ELISA), and 96.7%, 100% and 99.1% (for IC test). Conclusions These two assay methods showed high efficiencies and precisions for diagnosis of fasciolosis by F. gigantica. PMID:26731402

  13. Quantitative sandwich ELISA for the determination of fish in foods.

    Science.gov (United States)

    Faeste, Christiane K; Plassen, Christin

    2008-01-01

    Allergy to fish represents one of the most prevalent causes for severe food-allergic reactions. Therefore, food authorities in different countries have implemented mandatory labeling of fish in pre-packed foods. Detection of fish proteins in food has previously been based on the use of patient serum. In the present study, a novel sandwich enzyme-linked immunosorbent assay (ELISA) for the quantitation of fish in food matrixes has been developed and validated, using a polyclonal rabbit anti-cod parvalbumin antibody for capture and a biotinylated conjugate of the same antibody for detection. By employing the ubiquitous muscle protein parvalbumin as target the method succeeds to detect a variety of fish. However, the ELISA is specific for fish and does not cross-react with other species. Recoveries ranged from 68-138% in typical food matrixes, while the intra- and inter-assay precisions were parvalbumin ELISA with a limit of detection of 0.01 mg parvalbumin/kg food, about 5 mg fish/kg food, seems sufficient to detect fish protein traces in foods at levels low enough to minimize the risk for fish allergic consumers.

  14. Development of a sandwich ELISA for quantification of immunoglobulin G in mink blood

    DEFF Research Database (Denmark)

    Mathiesen, Ronja; Chriél, Mariann; Struve, T.

    2016-01-01

    early immunity and thus their resistance against pathogenic agents found in the environment. This study describes a sandwich ELISA for quantification of the concentration of total immunoglobulin G in mink blood. The ELISA was validated with serum samples from females (n=8) and their kits (litters of 4...

  15. Immunodiagnostic monoclonal antibody-based sandwich ELISA of fasciolosis by detection of Fasciola gigantica circulating fatty acid binding protein.

    Science.gov (United States)

    Anuracpreeda, Panat; Chawengkirttikul, Runglawan; Sobhon, Prasert

    2016-09-01

    Up to now, parasitological diagnosis of fasciolosis is often unreliable and possesses low sensitivity. Hence, the detection of circulating parasite antigens is thought to be a better alternative for diagnosis of fasciolosis, as it reflects the real parasite burden. In the present study, a monoclonal antibody (MoAb) against recombinant Fasciola gigantica fatty acid binding protein (rFgFABP) has been produced. As well, a reliable sandwich enzyme-linked immunosorbent assay (sandwich ELISA) has been developed for the detection of circulating FABP in the sera of mice experimentally and cattle naturally infected with F. gigantica. MoAb 3A3 and biotinylated rabbit anti-recombinant FABP antibody were selected due to their high reactivities and specificities. The lower detection limit of sandwich ELISA was 5 pg mL-1, and no cross-reaction with other parasite antigens was observed. This assay could detect F. gigantica infection from day 1 post infection. In experimental mice, the sensitivity, specificity and accuracy of this assay were 93·3, 100 and 98·2%, while in natural cattle they were 96·7, 100 and 99·1%. Hence, this sandwich ELISA method showed high efficiencies and precisions for diagnosis of fasciolosis by F. gigantica.

  16. Immunodiagnosis of Fasciola gigantica Infection Using Monoclonal Antibody-Based Sandwich ELISA and Immunochromatographic Assay for Detection of Circulating Cathepsin L1 Protease.

    Science.gov (United States)

    Anuracpreeda, Panat; Chawengkirttikul, Runglawan; Sobhon, Prasert

    2016-01-01

    Tropical fasciolosis caused by Fasciola gigantica infection is one of the major diseases infecting ruminants in the tropical regions of Africa and Asia including Thailand. Parasitological diagnosis of fasciolosis is often unreliable and possesses low sensitivity. Therefore, the detection of circulating parasite antigens is thought to be a better alternative for diagnosis of fasciolosis, as it reflects the real parasite burden. In this study, we have produced a monoclonal antibody (MoAb) against recombinant F. gigantica cathepsin L1 (rFgCatL1), and developed both sandwich enzyme-linked immunosorbent assay (sandwich ELISA) and immunochromatographic (IC) test for rapid detection of circulating cathepsin L1 protease (CatL1) in the sera from mice experimentally and cattle naturally infected with Fasciola gigantica. MoAb 4E3 and biotinylated rabbit anti-recombinant CatL1 antibody were selected due to their high reactivities and specificities. The lower detection limits of sandwich ELISA and IC test were 3 pg/ml and 0.256 ng/ml, respectively. Sandwich ELISA and IC test could detect F. gigantica infection from day 1 to 35 post infection. In experimental mice, the sensitivity, specificity and accuracy were 95%, 100% and 98.6% (for sandwich ELISA), and 93%, 100% and 98.2% (for IC test), while in natural cattle they were 98.3%, 100% and 99.5% (for sandwich ELISA), and 96.7%, 100% and 99.1% (for IC test). These two assay methods showed high efficiencies and precisions for diagnosis of fasciolosis by F. gigantica.

  17. Development of a sandwich ELISA for the thrombin light chain identified by serum proteome analysis

    Directory of Open Access Journals (Sweden)

    Kazuyuki Sogawa

    2017-08-01

    Full Text Available We previously identified novel biomarker candidates in biliary tract cancer (BTC using serum proteome analysis. Among several candidates, we focused on thrombin light chain which is a 4204 Da peptide as the most promising biomarker for BTC. To move thrombin light chain toward potential diagnostic use, we developed an enzyme immunoassay that enables to measure serum thrombin light chain levels.Both one monoclonal antibody specific to the N-termini and one polyclonal antibody were used to develop a sandwich ELISA for thrombin light chain. The assay was evaluated by comparing the results with those obtained by the ClinProt™ system. Serum samples were obtained from 20 patients with BTC, 20 patients with BBTDs and 20 HVs using the ClinProt™ system and ELISA.The results of the established ELISA showed a positive correlation with the findings by ClinProt™ system (slope=0.3386, intercept=34.901, r2=0.9641. The performance of the ELISA was satisfactory in terms of recovery (97.9–102.5% and within-run (1.5–4.8% and between-day (1.9–6.7% reproducibility. Serum thrombin light chain levels were significantly greater in BTC (176.5±47.2 ng/mL than in BBTDs (128.6±17.4 ng/mL and HVs (127.6±16.0 ng/mL (p<0.001.The sandwich ELISA developed in this study will be useful for validation of the diagnostic significance of serum thrombin light chain levels in various cancers. Keywords: Thrombin light chain, Biliary tract cancer, Sandwich ELISA, Serum biomarker

  18. Development of a Monoclonal Antibody-Based Sandwich ELISA for Peanut Allergen Ara h 1 in Food

    Directory of Open Access Journals (Sweden)

    Chuanlai Xu

    2013-07-01

    Full Text Available We have established a highly sensitive sandwich enzyme-linked immunosorbent assay (ELISA based on two monoclonal antibodies (mAb to measure the content of the major peanut allergen Ara h 1 in foods. Two mAbs were selected out of 12 murine hybridoma cells secreting Ara h 1-specific antibody. Using mAb 6 as the capture antibody and HRP-labelled mAb 4 as the detection antibody, the limit of detection (LOD the assay was 0.34 ng/mL. Cross-reaction analysis showed that this method was strongly specific and had no cross-reactions with Ara h 2, pea protein or soy protein. Sample analysis showed that this ELISA was a useful tool to monitor peanut allergens in food products by measuring Ara h 1 content.

  19. Diagnostic efficacy of monoclonal antibody based sandwich enzyme linked immunosorbent assay (ELISA for detection of Fasciola gigantica excretory/secretory antigens in both serum and stool

    Directory of Open Access Journals (Sweden)

    Zoheiry Mona K

    2011-09-01

    Full Text Available Abstract Background This research was carried out to develop a reliable monoclonal antibody (MoAb-based sandwich enzyme linked immunosorbent assay (ELISA for the diagnosis of active Fasciola gigantica infection in both serum and stool for comparative purposes. Methods From a panel of MoAbs raised against F. gigantica excretory/secretory antigens (ES Ags, a pair (12B/11D/3F and 10A/9D/10G was chosen due to its high reactivity and strict specificity to F. gigantica antigen by indirect ELISA. Results The two MoAbs were of the IgG1 and IgG2a subclasses, respectively. Using SDS-PAGE and EITB, the selected MoAbs recognized 83, 64, 45 and 26 kDa bands of ES Ags. The lower detection limit of ELISA assay was 3 ng/ml. In stool, the sensitivity, specificity and diagnostic efficacy of ELISA was 96%, 98.2 and 97.1%; while in serum they were 94%, 94.6% and 94.3%, respectively. Moreover, a positive correlation was found between ova count in stool of F. gigantica infected patients and the OD readings of ELISA in both stool and serum samples (r = 0.730, p Conclusions These data showed that the use of MoAb-based sandwich ELISA for the detection of F. gigantica coproantigens in stool specimens was superior to serum samples; it provides a highly efficient, non-invasive technique for the diagnosis of active F. gigantica infection.

  20. Quantification of Pla or 3, a Platanus orientalis Allergen, Grown under Different Environmental Conditions, by Sandwich ELISA.

    Science.gov (United States)

    Sedghy, Farnaz; Sankian, Mojtaba; Moghadam, Maliheh; Varasteh, Abdol-Reza

    2016-10-01

    Platanus species are widely cultured around the world and considered an important cause of allergic reactions. In the present study, we developed a sandwich ELISA to quantify Pla or 3 allergen in P. orientalis pollen extracts grown near high-traffic roads and compared it to pollen extracts collected from rural areas as control. Pollen samples were collected from three polluted and two unpolluted sites in Mashhad, northeast Iran. Recombinant Pla or 3 was expressed and used for polyclonal antibody production in rabbit. A sandwich ELISA was developed and validated to quantify Pla or 3 levels in pollen extracts from the different sites. The coefficients of variation (CVs) for the intra- and inter- day assays were less than 5 and 18%, respectively. The working range of the standard curve was between 0.1 and 25 ng/ml, with the detection limit being 0.037 ng/ml. The recovery percentage was 88-106.4% at working concentrations from 0.31 to 26.5 ng/ml. Pla or 3 levels were significantly greater in pollens grown near high-traffic roads than in those grown in rural regions (p Pla or 3 in pollen extracts. Using this validated ELISA, we showed a substantial difference between the amounts of Pla or 3 in pollens grown in different environments. This finding should be considered in developing public policies to reduce traffic pollution, which leads to reduced allergic reactions in atopic subjects.

  1. Development and primary application of ELISA method for detecting residual calf serum protein

    International Nuclear Information System (INIS)

    Li Hua; Yu Jiankun; Hong Chao; Long Ruixiang; Zhai Yougang; Xu Qiongfang; Cui Pingfang; Ding Xuefeng; Xie Zhongping

    2005-01-01

    To develop a new DAS-ELISA (double antibody sandwich ELISA) kit for detecting residual calf serum protein (CSP) in vaccines, calf sera from different district were pooled and used to immunize rabbits and hens respectively. Then, the IgY from yolk and the anti-CSP IgG from rabbit were separated and purified. The purified IgY was used as the coating antibody, and purified rabbit anti-CSP IgG was labeled by HRP. The optimal concentration of IgY was 25-30 μg/mL. The coating buffer was 0.01mol/L PBS(pH7.4) containing 0.4% glutin. The optimal dilutions of HRP-IgG were from 1:2000 to 1:3000. The sensitivity of this ELISA method was higher (up to 2.5μg/mL) than that of current RPHA, the variation coefficient was about 6.3%-9.4%, and the recovery rate was 90.4%-112.8%. Furthermore, there was no cross-reaction with sera of pig, monkey and guinea pig. Twenty lots of vaccines with Al(OH) 3 or without Al(OH) 3 were tested by ELISA and RPHA respectively. The results proved that the adjuvant of Al(OH) 3 had fewer influence on ELISA than on RPHA, the variation of PRHA among different lots of vaccines was more significant than ELISA. The ELISA method is a highly sensitive and useful method to detect CSP in vaccines. (authors)

  2. Sandwich enzyme-linked immunosorbent assay (ELISA) for measuring the concentration of, and detection of antibodies to, Aujeszky's disease virus.

    Science.gov (United States)

    Kardi, V; Szegletes, E; Perényi, T; Pergel, I; Smal, Z

    1990-01-01

    A double antibody sandwich enzyme-linked immunosorbent assay (ELISA) was developed for measuring Aujeszky's disease virus (ADV) antigen concentration and an inhibition technique based on the former was developed for detection of antibodies to ADV. The results were checked by determining the cytopathic and serum neutralization titres. The correlation was satisfactory in both cases, with correlation coefficients above 0.8. When measuring ADV antigen concentration, the lower limit of detection was 10(3) TCID 50/0.2 ml. The sensitivity of ELISA in detecting antibodies to ADV was found to be superior to that of the serum neutralization test and, thus, enabled the testing of rabbit and guinea-pig sera.

  3. Quantitative Detection of the Foot-And-Mouth Disease Virus Serotype O 146S Antigen for Vaccine Production Using a Double-Antibody Sandwich ELISA and Nonlinear Standard Curves.

    Directory of Open Access Journals (Sweden)

    Xia Feng

    Full Text Available The efficacy of an inactivated foot-and-mouth disease (FMD vaccine is mainly dependent on the integrity of the foot-and-mouth disease virus (FMDV particles. At present, the standard method to quantify the active component, the 146S antigen, of FMD vaccines is sucrose density gradient (SDG analysis. However, this method is highly operator dependent and difficult to automate. In contrast, the enzyme-linked immunosorbent assay (ELISA is a time-saving technique that provides greater simplicity and sensitivity. To establish a valid method to detect and quantify the 146S antigen of a serotype O FMD vaccine, a double-antibody sandwich (DAS ELISA was compared with an SDG analysis. The DAS ELISA was highly correlated with the SDG method (R2 = 0.9215, P<0.01. In contrast to the SDG method, the DAS ELISA was rapid, robust, repeatable and highly sensitive, with a minimum quantification limit of 0.06 μg/mL. This method can be used to determine the effective antigen yields in inactivated vaccines and thus represents an alternative for assessing the potency of FMD vaccines in vitro. But it still needs to be prospectively validated by analyzing a new vaccine preparation and determining the proper protective dose followed by an in vivo vaccination-challenge study to confirm the ELISA findings.

  4. Quantitative Detection of the Foot-And-Mouth Disease Virus Serotype O 146S Antigen for Vaccine Production Using a Double-Antibody Sandwich ELISA and Nonlinear Standard Curves

    Science.gov (United States)

    Feng, Xia; Ma, Jun-Wu; Sun, Shi-Qi; Guo, Hui-Chen; Yang, Ya-Min; Jin, Ye; Zhou, Guang-Qing; He, Ji-Jun; Guo, Jian-Hong; Qi, Shu-yun; Lin, Mi; Cai, Hu; Liu, Xiang-Tao

    2016-01-01

    The efficacy of an inactivated foot-and-mouth disease (FMD) vaccine is mainly dependent on the integrity of the foot-and-mouth disease virus (FMDV) particles. At present, the standard method to quantify the active component, the 146S antigen, of FMD vaccines is sucrose density gradient (SDG) analysis. However, this method is highly operator dependent and difficult to automate. In contrast, the enzyme-linked immunosorbent assay (ELISA) is a time-saving technique that provides greater simplicity and sensitivity. To establish a valid method to detect and quantify the 146S antigen of a serotype O FMD vaccine, a double-antibody sandwich (DAS) ELISA was compared with an SDG analysis. The DAS ELISA was highly correlated with the SDG method (R2 = 0.9215, P<0.01). In contrast to the SDG method, the DAS ELISA was rapid, robust, repeatable and highly sensitive, with a minimum quantification limit of 0.06 μg/mL. This method can be used to determine the effective antigen yields in inactivated vaccines and thus represents an alternative for assessing the potency of FMD vaccines in vitro. But it still needs to be prospectively validated by analyzing a new vaccine preparation and determining the proper protective dose followed by an in vivo vaccination-challenge study to confirm the ELISA findings. PMID:26930597

  5. Development of a monoclonal antibody-based sandwich-type enzyme-linked immunosorbent assay (ELISA) for detection of abrin in food samples.

    Science.gov (United States)

    Zhou, Yu; Tian, Xiang-Li; Li, Yan-Song; Pan, Feng-Guang; Zhang, Yuan-Yuan; Zhang, Jun-Hui; Wang, Xin-Rui; Ren, Hong-Lin; Lu, Shi-Ying; Li, Zhao-Hui; Liu, Zeng-Shan; Chen, Qi-Jun; Liu, Jing-Qiu

    2012-12-15

    Abrin is a plant toxin, which can be easily isolated from the seeds of Abrus precatorius. It may be used as a biological warfare agent. In order to detect abrin in food samples, a two-layer sandwich format enzyme-linked immunosorbent assay based on the monoclonal antibody (mAb) (as capture antibody) and rabbit polyclonal serum (as detecting antibody) was developed and applied for the determination of abrin in some food matrices. The linear range of the mAb was 1-100 μg L(-1) with a detection limit of 0.5 μg L(-1) for abrin in phosphate buffered saline (PBS). The recoveries of abrin from sausage, beer and milk samples ranged 97.5-98.6%, 95.8-98.4% and 94.8-9.6%, respectively, with a coefficient of variation (CV) of 3.7% or less. The newly developed sandwich ELISA using the mAb appears to be a reliable and useful method for detection of abrin in sausage, beer and milk. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Optimisation of sandwich ELISA based on monoclonal antibodies for the specific measurement of pregnancy-associated plasma protein (PAPP-A) in acute coronary syndrome

    DEFF Research Database (Denmark)

    Rossen, Marie; Iversen, Kasper; Teisner, Ane

    2007-01-01

    OBJECTIVES: PAPP-A has become the principal biochemical serum marker in first trimester screening for Down syndrome, the original data being based on results of a radioimmunoassay (RIA). Recent observations using sandwich ELISA technology have proposed PAPP-A as a potential marker in patients wit...

  7. Purification of a polyclonal antibody against CD147 for ELISA using antigen-immunoaffinity chromatography

    Science.gov (United States)

    Liu, Shuangshuang; Li, Shasha; Zhang, Yang; Wang, Ye; Zhu, Yumeng; Wang, Bin; Chen, Zhi-Nan

    2017-01-01

    The immunoglobulin superfamily member CD147 is a widely expressed glycoprotein that occurs in both a membrane-spanning and soluble form. Sandwich ELISA is a powerful tool for analyzing soluble antigens. The aim of the present study was to obtain a highly specific polyclonal antibody against human CD147 that can be used for sandwich ELISA analysis. Expression of recombinant CD147 by a eukaryotic expression system was used to immunize rabbits to obtain antiserum. A highly specific polyclonal antibody that was able to detect soluble CD147 in sandwich ELISA was obtained by antigen-immunoaffinity chromatography purification. The purity of rabbit anti-CD147 polyclonal antibodies was ~99%, and ELISA analysis was able to determine the titer of the rabbit anti-CD147 polyclonal antibodies at 1:512,000. The lowest concentration of the standard CD147 antigen that the sandwich ELISA was able to detect was 31.25 pg/ml. The sandwich ELISA system was composed of anti-hepatoma HAb18 monoclonal antibodies and purified rabbit anti-CD147 polyclonal antibodies. The present study demonstrated that antigen-immunoaffinity chromatography may be a good technique for the purification of polyclonal antibodies, which may be used to detect antigen in sandwich ELISAs. PMID:28487989

  8. Detection of Human Epididymis Protein 4 (HE4) in Human Serum Samples Using a Specific Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Zhou, Lijun; Lv, Zhiqiang; Shao, Jing; Xu, Ying; Luo, Xiaohong; Zhang, Yuming; Hu, Yang; Zhang, Wenji; Luo, Shuhong; Fang, Jianmin; Wang, Ying; Duan, Chaohui; Huang, Ruopan

    2016-09-01

    The human epididymis protein 4 (HE4) may have high specificity in the detection of malignant diseases, making the development of an immunoassay for HE4 essential. In our study, a fusion gene was constructed encoded with the HE4 protein. This protein was then produced in the bacterial cells (Escherichia coli) and used to immunize mice in order to eventually generate hybridomas specific to HE4. The hybridoma supernatants were then screened, and four positive anti-HE4 cell lines were selected. These cell lines produce monoclonal antibodies against HE4 epitopes, as demonstrated in the Western blot as well as by direct enzyme-linked immunosorbent assay (ELISA). Using the developed antibodies, we successfully identified several good antibody pairs from the hybridomas, which allowed for the development of a sandwich ELISA to measure HE4 levels. By using the HE4 ELISA, we measured HE4 levels of 60 clinical human serum samples. Compared with the Food and Drug Administration (FDA) approved kit (Roche), our results showed a strong positive correlation to those of the FDA-approved kit. In summary, highly sensitive antibody pairs were screened against HE4, and a sandwich ELISA was developed as an accurate analytical tool for the detection of HE4 in human serum, which could be especially valuable for diagnosing ovarian carcinomas. © 2015 Wiley Periodicals, Inc.

  9. Development, standardisation and validation of ELISA methods to improve the control of trypanosomosis

    International Nuclear Information System (INIS)

    Rebeski, D.E.; Winger, E.M.; Robinson, M.M.; Dwinger, R.H.; Crowther, J.R.

    2000-01-01

    During the period from 1995 to 2000, comprehensive laboratory and field studies on enzyme-linked immunosorbent assay (ELISA) methods for detection of trypanosomal antibodies and antigens were undertaken to improve the proficiency of diagnostic laboratories involved in control of trypanosomosis in the tropics. The work was initiated by the FAO/IAEA through the Coordinated Research Programme D3.20.13 and undertaken in close collaboration with Research Agreement Holders and Research Contract Holders. Initially, the CRP facilitated the field evaluation of three direct sandwich antigen detection ELISAs based on monoclonal antibodies. Diagnostic laboratories were supported with ELISA equipment, disposables, and training. ELISA reagents were produced in sufficient quantities and distributed in a standardised kit format. As a result of the laboratory and field evaluation studies, the assays were found unreliable for trypanosomosis control and rejected for routine use in diagnostic laboratories. At that time, no standardised ELISA system was available for trypanosomosis that was considered suitable for distribution and use under tropical conditions. Through the CRP, a new generation of standardised antibody ELISAs were developed and established using a novel approach, namely the use of antigen-precoated ELISA plates. In addition, the potential of native and denatured trypanosomal antigens as diagnostic candidates was examined. In-house and field evaluation studies in the tropics demonstrated that a reasonable robustness with an acceptable diagnostic assay proficiency was achieved by means of utilising plates precoated with denatured antigens. Moreover, a data charting method for continuous monitoring of the operational performance of the ELISAs was developed and established. It was routinely used as remote control and follow up tool saving the need for costly expert missions to the diagnostic laboratories during the assay validation period. In parallel, preliminary studies

  10. Construction, expression, purification and biotin labeling of a single recombinant multi-epitope antigen for double-antigen sandwich ELISA to detect hepatitis C virus antibody.

    Science.gov (United States)

    He, Jing; Xiu, Bingshui; Wang, Guohua; Chen, Kun; Feng, Xiaoyan; Song, Xiaoguo; Zhu, Cuixia; Yang, Xiqin; Bai, Guanzhong; Ling, Shigan; Zhang, Heqiu

    2011-08-01

    Based on B cell epitope predictions, a recombinant antigen with multiple epitopes from four Hepatitis C Virus fragments (C, NS3, NS4 and NS5) were engineered. The recombinant gene was then highly expressed in E. coli. The non-modified and C-terminal-modified recombinant proteins were used for coating and biotin labeling, respectively, to establish the double-antigen sandwich ELISA. Ten positive reference samples confirmed by the CHIRON RIBA HCV 3.0 SIA kit were detected positive, Forty one plasma samples were positive among samples from 441 volunteers, which indicated that the recombinant antigen could readily react well with plasma HCV antibody. As critical reagents of double-antigen sandwich ELISA, the recombinant multi-epitope antigen and the C-terminal-modified and biotin-conjugated antigen show good antigenicity. In this study, we provide a simple approach to produce multiple epitopes within one recombinant protein in order to avoid the costly expression of less-effective pools of multiple proteins, which is the conventional strategy of diagnostic antigen production for HCV antibody detection.

  11. Immunodiagnosis of fascioliasis using sandwich enzyme-linked immunosorbent assay for detection of Fasciola gigantica paramyosin antigen

    Science.gov (United States)

    Abou-Elhakam, Hany Mohamed Adel; Bauomy, Ibraheem Rabia; El Deeb, Somaya Osman; El Amir, Azza Mohamed

    2013-01-01

    Background: Many immunological techniques have been developed over years using the different Fasciola antigens for diagnosis of parasitic infection and to replace the parasitological techniques, which are time consuming and usually lack sensitivity and reproducibility. Materials and Methods: In this study, Fasciola gigantica paramyosin (Pmy) antigen was early detected in cattle sera using sandwich enzyme-linked immunosorbent assay (ELISA), to evaluate the Pmy antigen performance in diagnosis. This work was conducted on 135 cattle blood samples, which were classified according to parasitological investigation into, healthy control (30), fascioliasis (75), and other parasites (30) groups. Results: The sensitivity of Sandwich ELISA was 97.33%, and the specificity was 95%, in comparison with parasitological examination, which recorded 66.66% sensitivity and 100% specificity, respectively. Conclusions: It was clear that the native F. gigantica Pmy is considered as a powerful antigen in early immunodiagnosis of fascioliasis, using a highly sensitive and specific sandwich ELISA technique. PMID:23961441

  12. Development of sandwich enzyme-linked immunosorbent assay systems for plasma β-galactoside α2,6-sialyltransferase, a possible hepatic disease biomarker

    International Nuclear Information System (INIS)

    Futakawa, Satoshi; Kitazume, Shinobu; Oka, Ritsuko; Ogawa, Kazuko; Hagiwara, Yoshiaki; Kinoshita, Akinori; Miyashita, Kazuya; Hashimoto, Yasuhiro

    2009-01-01

    Previous reports, including our work, have shown that plasma β-galactoside α2,6-sialyltransferase (ST6Gal I) activity is significantly increased in particular hepatopathological situations, suggesting that it may represent a sensitive biomarker for diagnosing hepatic diseases. So far, activity of ST6Gal I have been measured by using radioactive tracer method in place of measuring amount of ST6Gal I. However, this method is tangled and cannot exclude other sialyltransferase activities. Thus, simple and specific methods for measuring plasma ST6Gal I had been unavailable. Here, we developed two kinds of sandwich enzyme-linked immunosorbent assay (ELISA) systems that specifically detect the soluble cleaved form of ST6Gal I in plasma. In one sandwich ELISA, we detected rat specific sequence, EFQMPK, which is N-terminus of soluble ST6Gal I. In the other sandwich ELISA, we detected internal common sequence among rat, mouse and human ST6Gal I in plasma (M2 ELISA). Using the M2 ELISA, we observed that elevation of plasma ST6Gal I was much faster than elevation of plasma aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in a carbon tetrachloride (CCl 4 )-induced mouse liver injury model. Our data suggest that these ELISA systems are very useful tools for measuring plasma ST6Gal I, which represents a potential biomarker for diagnosing hepatic diseases

  13. Development of sandwich enzyme-linked immunosorbent assay systems for plasma {beta}-galactoside {alpha}2,6-sialyltransferase, a possible hepatic disease biomarker

    Energy Technology Data Exchange (ETDEWEB)

    Futakawa, Satoshi [Department of Biochemistry, School of Medicine, Fukushima Medical University, 1 Hikarigaoka, Fukushima-shi, Fukushima 960-1295 (Japan); Kitazume, Shinobu [Disease Glycomics Laboratory, Institute of Physical and Chemical Research, RIKEN, 2-1 Hirosawa, Wako-shi, Saitama 351-0198 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi-shi, Saitama 560-0082 (Japan); Oka, Ritsuko [CREST, Japan Science and Technology Agency, Kawaguchi-shi, Saitama 560-0082 (Japan); Glyco-chain Functions Laboratory, Institute of Physical and Chemical Research, RIKEN, 2-1 Hirosawa, Wako-shi, Saitama 351-0198 (Japan); Ogawa, Kazuko [Disease Glycomics Laboratory, Institute of Physical and Chemical Research, RIKEN, 2-1 Hirosawa, Wako-shi, Saitama 351-0198 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi-shi, Saitama 560-0082 (Japan); Hagiwara, Yoshiaki; Kinoshita, Akinori; Miyashita, Kazuya [Department of Biological Sciences, Immuno-Biological Laboratories Co. Ltd., 1091-1 Naka, Fujioka-shi, Gunma 375-0005 (Japan); Hashimoto, Yasuhiro [Department of Biochemistry, School of Medicine, Fukushima Medical University, 1 Hikarigaoka, Fukushima-shi, Fukushima 960-1295 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi-shi, Saitama 560-0082 (Japan)], E-mail: yasuc@fmu.ac.jp

    2009-01-05

    Previous reports, including our work, have shown that plasma {beta}-galactoside {alpha}2,6-sialyltransferase (ST6Gal I) activity is significantly increased in particular hepatopathological situations, suggesting that it may represent a sensitive biomarker for diagnosing hepatic diseases. So far, activity of ST6Gal I have been measured by using radioactive tracer method in place of measuring amount of ST6Gal I. However, this method is tangled and cannot exclude other sialyltransferase activities. Thus, simple and specific methods for measuring plasma ST6Gal I had been unavailable. Here, we developed two kinds of sandwich enzyme-linked immunosorbent assay (ELISA) systems that specifically detect the soluble cleaved form of ST6Gal I in plasma. In one sandwich ELISA, we detected rat specific sequence, EFQMPK, which is N-terminus of soluble ST6Gal I. In the other sandwich ELISA, we detected internal common sequence among rat, mouse and human ST6Gal I in plasma (M2 ELISA). Using the M2 ELISA, we observed that elevation of plasma ST6Gal I was much faster than elevation of plasma aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in a carbon tetrachloride (CCl{sub 4})-induced mouse liver injury model. Our data suggest that these ELISA systems are very useful tools for measuring plasma ST6Gal I, which represents a potential biomarker for diagnosing hepatic diseases.

  14. Estimation of serum thyroglobulin using isotopic and non-isotopic methods: a comparison between RIA, IRMA and ELISA

    International Nuclear Information System (INIS)

    Ajay Kumar; Velumani, A.; Dandekar, S.R.; Shah, D.H.; Rajashekharrao, B.

    1997-01-01

    Three in-house immunoassays viz, RIA, IRMA and ELISA for estimation of serum Tg were compared for their assay characteristics and clinical utility. The inter- and intra-assay coefficient of variations of RIA and IRMA were comparable and were marginally better than that of ELISA. The sensitivity of IRMA was superior to RIA which in turn was superior than ELISA. Incubation time for both IRMA and ELISA was 4 h as compared to 90 h required for RIA. The enzyme conjugated antibody had longest shelf-life (9 months) followed by radiolabeled antibody (3 months) while radiolabeled Tg had shortest shelf-life (3 weeks). There was no interference from circulating anti-Tg autoantibodies in the RIA of Tg as compared to a gross underestimation observed in both sandwich methods. Assays correlated well with each other (r > 0.85, n=200) and had suitable clinical utility (sensitivity > 93% and specificity > 89%). Each assay though had its own merits and demerits, yet it served the clinical utility for an effective management of patients with differentiated thyroid carcinoma. (author)

  15. A High-Throughput, Precipitating Colorimetric Sandwich ELISA Microarray for Shiga Toxins

    Directory of Open Access Journals (Sweden)

    Andrew Gehring

    2014-06-01

    Full Text Available Shiga toxins 1 and 2 (Stx1 and Stx2 from Shiga toxin-producing E. coli (STEC bacteria were simultaneously detected with a newly developed, high-throughput antibody microarray platform. The proteinaceous toxins were immobilized and sandwiched between biorecognition elements (monoclonal antibodies and pooled horseradish peroxidase (HRP-conjugated monoclonal antibodies. Following the reaction of HRP with the precipitating chromogenic substrate (metal enhanced 3,3-diaminobenzidine tetrahydrochloride or DAB, the formation of a colored product was quantitatively measured with an inexpensive flatbed page scanner. The colorimetric ELISA microarray was demonstrated to detect Stx1 and Stx2 at levels as low as ~4.5 ng/mL within ~2 h of total assay time with a narrow linear dynamic range of ~1–2 orders of magnitude and saturation levels well above background. Stx1 and/or Stx2 produced by various strains of STEC were also detected following the treatment of cultured cells with mitomycin C (a toxin-inducing antibiotic and/or B-PER (a cell-disrupting, protein extraction reagent. Semi-quantitative detection of Shiga toxins was demonstrated to be sporadic among various STEC strains following incubation with mitomycin C; however, further reaction with B-PER generally resulted in the detection of or increased detection of Stx1, relative to Stx2, produced by STECs inoculated into either axenic broth culture or culture broth containing ground beef.

  16. An ELISA for the quantitation of von Willebrand Factor

    DEFF Research Database (Denmark)

    Vinholt, Pernille Just; Overgaard, Martin; Diederichsen, Axel Cosmus Pyndt

    2013-01-01

    for measurement of von Willebrand factor-osteoprotegerin complex (VWF:OPG) in human plasma. Furthermore, the significance of VWF:OPG complex as a marker of cardiovascular disease (CVD) was evaluated. PATIENTS/METHODS: A sandwich ELISA for quantification of VWF:OPG was developed using a polyclonal rabbit anti...... with and without documented coronary calcification (total n=118). RESULTS AND CONCLUSIONS: The assay detected VWF:OPG complexes in human plasma, while no significant signal was observed when testing solutions containing VWF or recombinant OPG alone. Importantly, the ELISA assay was able to detect in vitro formed...

  17. Sandwich Structured Composites for Aeronautics: Methods of Manufacturing Affecting Some Mechanical Properties

    Directory of Open Access Journals (Sweden)

    Aneta Krzyżak

    2016-01-01

    Full Text Available Sandwich panels are composites which consist of two thin laminate outer skins and lightweight (e.g., honeycomb thick core structure. Owing to the core structure, such composites are distinguished by stiffness. Despite the thickness of the core, sandwich composites are light and have a relatively high flexural strength. These composites have a spatial structure, which affects good thermal insulator properties. Sandwich panels are used in aeronautics, road vehicles, ships, and civil engineering. The mechanical properties of these composites are directly dependent on the properties of sandwich components and method of manufacturing. The paper presents some aspects of technology and its influence on mechanical properties of sandwich structure polymer composites. The sandwiches described in the paper were made by three different methods: hand lay-up, press method, and autoclave use. The samples of sandwiches were tested for failure caused by impact load. Sandwiches prepared in the same way were used for structural analysis of adhesive layer between panels and core. The results of research showed that the method of manufacturing, more precisely the pressure while forming sandwich panels, influences some mechanical properties of sandwich structured polymer composites such as flexural strength, impact strength, and compressive strength.

  18. Detection of ciguatoxin in fish tissue using sandwich ELISA and neuroblastoma cell bioassay.

    Science.gov (United States)

    Empey Campora, Cara; Dierking, Jan; Tamaru, Clyde S; Hokama, Yoshitsugi; Vincent, Douglas

    2008-01-01

    The applicability of a new enzyme-linked immunoassay (ELISA) for detecting ciguatoxin (CTX) in fish tissue was evaluated by testing three fish species commonly implicated in ciguatera fish poisoning in Hawaii. A total of 164 individual almaco jack (Seriola rivoliana) and greater amberjack (S. dumerili) and a total of 175 individuals of the blue-spotted grouper (Cephalopholis argus) were caught at various locations in the Hawaiian Islands. Muscle tissue from each individual was assessed for the presence of CTX using two methods: a semi-quantitative ELISA that was recently developed for detecting picogram levels of CTX in fish extract and a neuroblastoma (NB) cell assay commonly used to screen for marine toxins in fish. Results of the tests were highly correlated, with the ELISA indicating the presence of CTX in 9.4% of all fish samples, and the NB assay indicating toxicity in 6.8% of the fish samples. We conclude that the ELISA produces reliable and accurate results that are consistent with those provided by the accepted NB assay and that the ELISA has potential for future applications in screening fish populations for CTX.

  19. Laboratory safe detection of nucleocapsid protein of Rift Valley fever virus in human and animal specimens by a sandwich ELISA.

    Science.gov (United States)

    Jansen van Vuren, P; Paweska, J T

    2009-04-01

    A safe laboratory procedure, based on a sandwich ELISA (sAg-ELISA), was developed and evaluated for the detection of nucleocapsid protein (NP) of Rift Valley fever virus (RVFV) in specimens inactivated at 56 degrees C for 1h in the presence of 0.5% Tween-20 (v/v) before testing. Polyclonal capture and detection immune sera were generated respectively in sheep and rabbits immunized with recombinant NP antigen. The assay was highly repeatable and specific; it detected strains of RVFV from the entire distributional range of the disease, isolated over a period of 53 years; no cross-reactivity with genetically related African phleboviruses or other members of the family Bunyaviridae was observed. In specimens spiked with RVFV, including human and animal sera, homogenates of liver and spleen tissues of domestic ruminants, and Anopheles mosquito homogenates, the sAg-ELISA detection limit ranged from log(10)10(2.2) to 10(3.2) TCID(50)/reaction volume. The ELISA detected NP antigen in spiked bovine and sheep liver homogenates up to at least 8 days of incubation at 37 degrees C whereas infectious virus could not be detected at 48h incubation in these adverse conditions. Compared to virus isolation from sera from RVF patients and sheep infected experimentally, the ELISA had 67.7% and 70% sensitivity, and 97.97% and 100% specificity, respectively. The assay was 100% accurate when testing tissues of various organs from mice infected experimentally and buffalo foetuses infected naturally. The assay was able to detect NP antigen in infective culture supernatants 16-24h before cytopathic effects were observed microscopically and as early as 8h after inoculation with 10(5.8) TCID(50)/ml of RVFV. This ability renders the assay for rapid identification of the virus when its primary isolation is attempted in vitro. As a highly specific, safe and simple assay format, the sAg-ELISA represents a valuable diagnostic tool for use in less equipped laboratories in Africa, and for routine

  20. Preparation of anti-ciguatoxin monoclonal antibodies using synthetic haptens: sandwich ELISA detection of ciguatoxins.

    Science.gov (United States)

    Tsumuraya, Takeshi; Fujii, Ikuo; Hirama, Masahiro

    2014-01-01

    Ciguatera fish poisoning (CFP) is a form of food poisoning caused by the consumption of fish that have accumulated a type of sodium channel activator toxin called ciguatoxins (CTXs), which are produced by dinoflagellates of the genus Gambierdiscus through the food chain. CFP affects more than 50000 people each year. The extremely low level of CTXs in tainted fish has hampered the development of antibodies for the detection of these toxins. Monoclonal antibodies (mAbs) specific against major congeners of CTX3C, 51-hydroxyCTX3C, CTX1B, and 54-deoxyCTX1B were prepared by immunization of mice with protein conjugates of rationally designed synthetic haptens in place of the natural toxins. We found that haptenic groups possessing a surface area larger than 400 angstroms2 were required to produce mAbs that can bind strongly to CTXs. Direct sandwich ELISA utilizing two different monoclonal antibodies that bind specifically to one of the two wings of a CTX were established to detect CTXs. No cross-reactivity was observed against the other marine toxins tested, including brevetoxin A, brevetoxin B, okadaic acid, and maitotoxin.

  1. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    Science.gov (United States)

    Parma, Y. R.; Chacana, P. A.; Lucchesi, P. M. A.; Rogé, A.; Granobles Velandia, C. V.; Krüger, A.; Parma, A. E.; Fernández-Miyakawa, M. E.

    2012-01-01

    Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic-uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-Stx2B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933, and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 115 ng/ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for two strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli. PMID:22919675

  2. Development of a species-specific coproantigen ELISA for human Taenia solium taeniasis.

    Science.gov (United States)

    Guezala, Maria-Claudia; Rodriguez, Silvia; Zamora, Humberto; Garcia, Hector H; Gonzalez, Armando E; Tembo, Alice; Allan, James C; Craig, Philip S

    2009-09-01

    Taenia solium causes human neurocysticercosis and is endemic in underdeveloped countries where backyard pig keeping is common. Microscopic fecal diagnostic methods for human T. solium taeniasis are not very sensitive, and Taenia saginata and Taenia solium eggs are indistinguishable under the light microscope. Coproantigen (CoAg) ELISA methods are very sensitive, but currently only genus (Taenia) specific. This paper describes the development of a highly species-specific coproantigen ELISA test to detect T. solium intestinal taeniasis. Sensitivity was maintained using a capture antibody of rabbit IgG against T. solium adult whole worm somatic extract, whereas species specificity was achieved by utilization of an enzyme-conjugated rabbit IgG against T. solium adult excretory-secretory (ES) antigen. A known panel of positive and negative human fecal samples was tested with this hybrid sandwich ELISA. The ELISA test gave 100% specificity and 96.4% sensitivity for T. solium tapeworm carriers (N = 28), with a J index of 0.96. This simple ELISA incorporating anti-adult somatic and anti-adult ES antibodies provides the first potentially species-specific coproantigen test for human T. solium taeniasis.

  3. Extension of the ELISA method to the measurement of the specific radioactivity of viruses in crude cellular extracts

    Energy Technology Data Exchange (ETDEWEB)

    Konate, G; Fritig, B [Institut de Biologie Moleculaire et Cellulaire, 67-Strasbourg (France). Lab. de Virologie

    1983-06-01

    The double-antibody sandwich method of ELISA, which allows accurate quantitative determination of plant viruses, was extended to a radiochemical procedure which permits direct measurement of the specific radioactivity of virus labelled in vivo and present in very crude plant homogenates. Evidence is presented showing that 20 to 50% of the virus introduced in the polystyrene wells during the antigen incubation step could be trapped in the sandwich. The percentage of virus bound increased with the concentration of the coating antibody and was almost proportional to the concentration of the antigen and to the incubation time of the antigens. Complete dissociation of the double-antibody sandwich was achieved by incubation with 0.2 M KOH or NaOH (pH 13.3), and the label carried by the virus was measured by scintillation counting of the solubilization fluid. The ratio infected/healthy was much higher for the radiochemical procedure than for the immunosorbent assay itself since binding of the virus to the coating antibody was not accompanied by any nonspecific trapping of radioactive contaminants in the double-antibody sandwich. The procedure was highly sensitive since the background corresponded to the scintillation counting background. The detection of the label carried by tobacco mosaic virus was possible when the tobacco samples contained at least 5 ng of virus carrying a label as low as 40 dpm /sup 3/H or 20 dpm /sup 14/C.

  4. Implementation of microfluidic sandwich ELISA for superior detection of plant pathogens.

    Science.gov (United States)

    Thaitrong, Numrin; Charlermroj, Ratthaphol; Himananto, Orawan; Seepiban, Channarong; Karoonuthaisiri, Nitsara

    2013-01-01

    Rapid and economical screening of plant pathogens is a high-priority need in the seed industry. Crop quality control and disease surveillance demand early and accurate detection in addition to robustness, scalability, and cost efficiency typically required for selective breeding and certification programs. Compared to conventional bench-top detection techniques routinely employed, a microfluidic-based approach offers unique benefits to address these needs simultaneously. To our knowledge, this work reports the first attempt to perform microfluidic sandwich ELISA for Acidovorax citrulli (Ac), watermelon silver mottle virus (WSMoV), and melon yellow spot virus (MYSV) screening. The immunoassay occurs on the surface of a reaction chamber represented by a microfluidic channel. The capillary force within the microchannel draws a reagent into the reaction chamber as well as facilitates assay incubation. Because the underlying pad automatically absorbs excess fluid, the only operation required is sequential loading of buffers/reagents. Buffer selection, antibody concentrations, and sample loading scheme were optimized for each pathogen. Assay optimization reveals that the 20-folds lower sample volume demanded by the microchannel structure outweighs the 2- to 4-folds higher antibody concentrations required, resulting in overall 5-10 folds of reagent savings. In addition to cutting the assay time by more than 50%, the new platform offers 65% cost savings from less reagent consumption and labor cost. Our study also shows 12.5-, 2-, and 4-fold improvement in assay sensitivity for Ac, WSMoV, and MYSV, respectively. Practical feasibility is demonstrated using 19 real plant samples. Given a standard 96-well plate format, the developed assay is compatible with commercial fluorescent plate readers and readily amendable to robotic liquid handling systems for completely hand-free assay automation.

  5. Implementation of microfluidic sandwich ELISA for superior detection of plant pathogens.

    Directory of Open Access Journals (Sweden)

    Numrin Thaitrong

    Full Text Available Rapid and economical screening of plant pathogens is a high-priority need in the seed industry. Crop quality control and disease surveillance demand early and accurate detection in addition to robustness, scalability, and cost efficiency typically required for selective breeding and certification programs. Compared to conventional bench-top detection techniques routinely employed, a microfluidic-based approach offers unique benefits to address these needs simultaneously. To our knowledge, this work reports the first attempt to perform microfluidic sandwich ELISA for Acidovorax citrulli (Ac, watermelon silver mottle virus (WSMoV, and melon yellow spot virus (MYSV screening. The immunoassay occurs on the surface of a reaction chamber represented by a microfluidic channel. The capillary force within the microchannel draws a reagent into the reaction chamber as well as facilitates assay incubation. Because the underlying pad automatically absorbs excess fluid, the only operation required is sequential loading of buffers/reagents. Buffer selection, antibody concentrations, and sample loading scheme were optimized for each pathogen. Assay optimization reveals that the 20-folds lower sample volume demanded by the microchannel structure outweighs the 2- to 4-folds higher antibody concentrations required, resulting in overall 5-10 folds of reagent savings. In addition to cutting the assay time by more than 50%, the new platform offers 65% cost savings from less reagent consumption and labor cost. Our study also shows 12.5-, 2-, and 4-fold improvement in assay sensitivity for Ac, WSMoV, and MYSV, respectively. Practical feasibility is demonstrated using 19 real plant samples. Given a standard 96-well plate format, the developed assay is compatible with commercial fluorescent plate readers and readily amendable to robotic liquid handling systems for completely hand-free assay automation.

  6. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    Directory of Open Access Journals (Sweden)

    Yanil R Parma

    2012-06-01

    Full Text Available Enterohemorrhagic Escherichia coli (EHEC, a subset of Shiga toxin producing E. coli (STEC is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic uremic syndrome (HUS. Regardless of serotype, Shiga toxins (Stx1 and/or Stx2 are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx was developed using anti-Stx2 B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933 and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 400 ng /ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for 2 strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli.

  7. Determination of Aspergillus pathogens in agricultural products by a specific nanobody-polyclonal antibody sandwich ELISA.

    Science.gov (United States)

    Wang, Ting; Li, Peiwu; Zhang, Qi; Zhang, Wen; Zhang, Zhaowei; Wang, Tong; He, Ting

    2017-06-28

    Aspergillus and its poisonous mycotoxins are distributed worldwide throughout the environment and are of particular interest in agriculture and food safety. In order to develop a specific method for rapid detection of Aspergillus flavus to forecast diseases and control aflatoxins, a nanobody, PO8-VHH, highly reactive to A. flavus was isolated from an immunized alpaca nanobody library by phage display. The nanobody was verified to bind to the components of extracellular and intracellular antigen from both A. flavus and A. parasiticus. To construct a sandwich format immunoassay, polyclonal antibodies against Aspergillus were raised with rabbits. Finally, a highly selective nanobody-polyclonal antibody sandwich enzyme-linked immunosorbent assay was optimized and developed. The results revealed that the detection limits of the two fungi were as low as 1 μg mL -1 , and that it is able to detect fungal concentrations below to 2 μg mg -1 of peanut and maize grains in both artificially and naturally contaminated samples. Therefore, we here provided a rapid and simple method for monitoring Aspergillus spp. contamination in agricultural products.

  8. Streptavidin-biotin-based directional double Nanobody sandwich ELISA for clinical rapid and sensitive detection of influenza H5N1.

    Science.gov (United States)

    Zhu, Min; Gong, Xue; Hu, Yonghong; Ou, Weijun; Wan, Yakun

    2014-12-20

    Influenza H5N1 is one subtype of the influenza A virus which can infect human bodies and lead to death. Timely diagnosis before its breakout is vital to the human health. The current clinical biochemical diagnosis for influenza virus are still flawed, and the diagnostic kits of H5N1 are mainly based on traditional monoclonal antibodies that hardly meet the requirements for clinical applications. Nanobody is a promising tool for diagnostics and treatment due to its smallest size, high specificity and stability. In this study, a novel Nanobody-based bioassay was developed for rapid, low-cost and sensitive detection of the influenza H5N1 virus. Nanobodies specific to H5N1 virus were selected from a VHH library by phage display technology. In this system, the biotinylated Nanobody was directionally captured by streptavidin coated on ELISA plate, which can specifically capture the H5N1 virus. Another Nanobody conjugated with HRP was used as a detector. A novel directional enzyme-linked immunosorbent assay for H5N1 using specific Nanobodies was established and compared to the conventional undirected ELISA assay. We have successfully constructed a high quality phage display Nanobody library and isolated two Nanobodies against H5N1 with high affinity and specificity. These two Nanobodies were further used to prepare the biosensor detection system. This streptavidin-biotin-based directional double Nanobodies sandwich ELISA for H5N1 detection showed superiority over the commonly undirectional ELISA protocol. The linear range of detection for standards in this immunoassay was approximately 50-1000 ng/mL and the detection limit was 14.1 ng/mL. The average recoveries of H5N1 virus from human serum samples were in the range from 94.58% to 114.51%, with a coefficient of variation less than 6.5%. Collectively, these results demonstrated that the proposed detection system is an alternative diagnostic tool that enables a rapid, inexpensive, sensitive and specific detection of the

  9. Evaluation of a Commercial Sandwich Enzyme-Linked Immunosorbent Assay for the Quantification of Beta-Casomorphin 7 in Yogurt Using Solid-Phase Extraction Coupled to Liquid Chromatography-Tandem Mass Spectrometry as the "Gold Standard" Method.

    Science.gov (United States)

    Nguyen, Duc Doan; Busetti, Francesco; Johnson, Stuart Keith; Solah, Vicky Ann

    2018-03-01

    This study investigated beta-casomorphin 7 (BCM7) in yogurt by means of LC-tandem MS (MS/MS) and enzyme-linked immunosorbent assay (ELISA) and use LC-MS/MS as the "gold standard" method to evaluate the applicability of a commercial ELISA. The level of BCM7 in milk obtained from ELISA analysis was much lower than that obtained by LC-MS/MS analysis and trended to increase during fermentation and storage of yogurt. Meanwhile, the results obtained from LC-MS/MS showed that BCM7 degraded during stages of yogurt processing, and its degradation may have been caused by X-prolyl dipeptidyl aminopeptidase activity. As a result, the commercial sandwich ELISA kit was not suitable for the quantification of BCM7 in fermented dairy milk.

  10. Exploiting Nanobodies in the Detection and Quantification of Human Growth Hormone via Phage-Sandwich Enzyme-Linked Immunosorbent Assay

    Directory of Open Access Journals (Sweden)

    Hossam Murad

    2017-05-01

    Full Text Available BackgroundMonitoring blood levels of human growth hormone (hGH in most children with short stature deficiencies is crucial for taking a decision of treatment with extended course of daily and expensive doses of recombinant hGH (rhGH or Somatropin®. Besides, misusing of rhGH by sportsmen is banned by the World Anti-Doping Agency and thus sensitive GH-detecting methods are highly welcome in this field. Nanobodies are the tiniest antigen-binding entity derived from camel heavy chain antibodies. They were successfully generated against numerous antigens including hormones.MethodsA fully nanobody-based sandwich ELISA method was developed in this work for direct measurement of GH in biological samples.ResultsTwo major characteristics of nanobody were exploited for this goal: the robust and stable structure of the nanobody (NbGH04 used to capture hGH from tested samples, and the great ability of tailoring, enabling the display of the anti-GH detector nanobody (NbGH07 on the tip of M13-phage. Such huge, stable, and easy-to-prepare phage-Nb was used in ELISA to provide an amplified signal. Previously, NbGH04 was retrieved on immobilized hGH by phage display from a wide “immune” cDNA library prepared from a hGH-immunized camel. Here, and in order to assure epitope heterogeneity, NbGH07 was isolated from the same library using NbGH04-captured hGH as bait. Interaction of both nanobodies with hGH was characterized and compared with different anti-GH nanobodies and antibodies. The sensitivity (~0.5 ng/ml and stability of the nanobody-base sandwich ELISA were assessed using rhGH before testing in the quantification of hGH in blood sera and cell culture supernatants.ConclusionIn regard to all advantages of nanobodies; stability, solubility, production affordability in Escherichia coli, and gene tailoring, nanobody-based phage sandwich ELISA developed here would provide a valuable method for hGH detection and quantification.

  11. Detection and confirmation of PPR virus antigen in sheep and goats by sandwich-ELISA and RT-PCR in Andhra Pradesh, India

    Directory of Open Access Journals (Sweden)

    G. Saritha

    2015-06-01

    Full Text Available Peste des petits ruminants (PPR is a highly contagious disease of domestic and wild small ruminants. Rapid and accurate laboratory assay are essential to enable the implementation of appropriate control strategies to restrict the spread of PPR. The present study was designed to detect the PPR virus (PPRV antigen (N-gene in nasal swabs and tissue samples. A total of 195 samples comprising of 138 nasal swabs from PPR suspected sheep (n=72 and goats (n=66, and 57 tissue samples comprising of lymph nodes from dead sheep (n=39 and goats (n=18 were collected from certain parts of Andhra Pradesh. The samples were subjected to sandwich-ELISA followed by RT-PCR for confirmatory diagnosis. In this study, PPRV could be detected in 27.53% (n=38/138 nasal swabs and 49.12% (n=28/57 tissue samples. Data showed that PPRV infection is widespread in the Andhra Pradesh, India.

  12. An enzyme-linked immunosorbent assay (ELISA) for quantification of human collectin 11 (CL-11, CL-K1)

    DEFF Research Database (Denmark)

    Selman, L; Henriksen, M L; Brandt, J

    2012-01-01

    -associated serine protease 1 (MASP-1) and/or MASP-3 in circulation. Mutation in the CL-11 gene was recently associated with the developmental syndrome 3MC. In the present study, we established and thoroughly validated a sandwich enzyme-linked immunosorbent assay (ELISA) based on two different monoclonal antibodies....... The assay is highly sensitive, specific and shows excellent quantitative characteristics such as reproducibility, dilution linearity and recovery (97.7-104%). The working range is 0.15-34 ng/ml. The CL-11 concentration in two CL-11-deficient individuals affected by the 3MC syndrome was determined...... and thawing to a certain extent did not influence the ELISA. This ELISA offers a convenient and reliable method for studying CL-11 levels in relation to a variety of human diseases and syndromes....

  13. Different conformational forms of serum carnosinase detected by a newly developed sandwich ELISA for the measurements of carnosinase concentrations

    NARCIS (Netherlands)

    Adelmann, Katja; Frey, Dirk; Riedl, Eva; Koeppel, Hannes; Pfister, Frederick; Peters, Verena; Schmitt, Claus P.; Sternik, Paula; Hofmann, Stephanie; Zentgraf, Hans Walter; Navis, Gerjan; van den Born, Jacob; Bakker, Stephan J. L.; Kraemer, Bernhard K.; Yard, Benito A.; Hauske, Sibylle J.

    Serum carnosinase (CN-1) measurements are at present mainly performed by assessing enzyme activity. This method is time-consuming, not well suited for large series of samples and can be discordant to measurements of CN-1 protein concentrations. To overcome these limitations, we developed sandwich

  14. Measurement of the epithermal neutron flux of the Argonauta reactor by the Sandwich method

    International Nuclear Information System (INIS)

    Nascimento, H.M.

    1973-01-01

    A common method of obtaining information about the neutron spectrum in the energy range of 1 eV to a few keV is by using resonance sandwich detectors. A sandwich detector is usually made up of three foils placed one on top of the other, each having the same thickness and being made of the same material which has a pronounced absorption resonance. To make an adequate evaluation, the sandwich method was compared with one using an isolated detector. The results obtained from approximate theoretical calculations were checked experimentally, using In, Au and Mn foils, in an isotropic 1/E flux in the Argonaut Reactor at I.E.N. As practical application of this method, the deviation from a 1/E spectrum of the epithermal neutron flux in the core and external graphite reflector of the Argonaut Reactor has been measured with the sandwich foils previously calibrated in a 1/E spectrum. (author)

  15. Sandwich-dot enzyme-linked immunosorbent assay for the detection of canine distemper virus

    Science.gov (United States)

    Li, Zhi; Zhang, Yanlong; Wang, Huiguo; Jin, Jinhua; Li, Wenzhe

    2013-01-01

    A sandwich-dot enzyme-linked immunosorbent assay (dot ELISA) was developed for the detection of canine distemper virus (CDV). In 56 dogs suspected to have CD the rates of detection of CDV antigen in samples of blood lymphocytes and palpebral conjunctiva by dot ELISA and ELISA were, respectively, 91% (49/54) and 81% (44/54) for the lymphocyte samples and 88% (28/32) and 75% (24/32) for the conjunctival samples. The CDV detection limits were 10 ng/50 μL for dot ELISA and 40 ng/50 μL for ELISA. The reliability of dot ELISA relative to electron microscopy was 96% with 22 samples: all 21 samples in which CDV particles were observed by electron microscopy yielded positive results with dot ELISA; the single sample in which particles were not observed yielded false-positive results with dot ELISA. The results indicate that the dot ELISA developed can serve as a reliable rapid diagnostic test in suspected cases of CD and also be useful for epidemiologic surveillance of the disease. PMID:24124274

  16. The Platelia Aspergillus ELISA in diagnosis of invasive pulmonary aspergilosis (IPA).

    Science.gov (United States)

    Siemann, M; Koch-Dörfler, M

    2001-01-01

    The sensitivity of a sandwich enzyme-linked immunosorbent assay (ELISA) for detecting Aspergillus galactomannan was evaluated with 66 serum samples and 113 specimens of the respiratory tract obtained from 52 patients with pulmonary diseases. The patients were divided into five groups: proven invasive pulmonary aspergillosis (IPA) (five patients), probable IPA (seven patients), Aspergillus colonization (eight patients) or unlikely Aspergillus infection (27 patients). Another five patients with doubtful diagnostic test results are discussed in detail. The results of the Platelia Aspergillus ELISA (Sanofi Pasteur, Freiburg, Germany) in testing specimens of the respiratory tract were 90% sensitivity in proven (serum 38%), 60% in probable (serum 37%) and 71% in Aspergillus colonization (serum 0%). Furthermore, 85% of the Aspergillus spp. from positive cultures of specimens of the respiratory tract were also detected in the ELISA. A total of 57% of the culture negative specimens of patients with a least one positive culture or proven aspergillosis in a series of specimens were positive in the ELISA.

  17. Detection of potato mop-top virus in soils and potato tubers using bait-plant bioassay, ELISA and RT-PCR.

    Science.gov (United States)

    Arif, Muhammad; Ali, Murad; Rehman, Anayatur; Fahim, Muhammad

    2014-01-01

    The hilly region of Northwest of Pakistan is leading seed potato producing areas of the country. Soil and plant samples were collected from the region and tested for PMTV using both conventional and molecular techniques. The bait plants exhibited PMTV-characteristic v-shaped yellow leaf markings in Nicotiana debneyi plants grown in putative viruliferious soils from 20/26 locations. The results were confirmed by back inoculation of sap from both roots and leaves of bait plant on indicator hosts (N. debneyi, Nicotiana benthamiana). The root samples of bait plants grown in soils of 25 locations and leaves of 24 locations reproduced systemic infection on indicator hosts upon back inoculation. The virus was identified in bait plants grown in soils from 25/26 locations using double antibody sandwich-enzyme linked immunosorbent assay (DAS)-ELISA and reverse transcription and polymerase chain reaction (RT-PCR) methods. The products of the 566bp were amplified from coat protein region of PMTV RNA 3 in both root and leaf samples of baited plants. The virus was detected in 10 potato cultivars commercially grown in the region using DAS-ELISA and RT-PCR. The virus was also detected in zoospores of Spongospora subterranea derived from the peels of selected scabby tubers using triple antibody sandwich (TAS)-ELISA. The results indicate that a bait plant bioassay, infectivity assay, ELISA and RT-PCR can detect PMTV in roots and leaves of baited plants, field samples, zoospores of S. subterranea and tubers of 10 potato cultivars commercially grown in the region. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Radioimmunoassays and 2-site immunoradiometric "sandwich" assays: basic principles.

    Science.gov (United States)

    Rodbard, D

    1988-10-01

    The "sandwich" or noncompetitive reagent-excess, 2-site immunoradiometric assay (2-site IRMA), ELISA, USERIA, and related techniques, have several advantages compared with the traditional or competitive radioimmunoassays. IRMAs can provide improved sensitivity and specificity. However, IRMAs present some practical problems with nonspecific binding, increased consumption of antibody, biphasic dose response curve, (high dose hook effect), and may require special techniques for dose response curve analysis. We anticipate considerable growth in the popularity and importance of 2-site IRMA.

  19. Radioimmunoassays and 2-site immunoradiometric 'sandwich' assays: basic principles

    Energy Technology Data Exchange (ETDEWEB)

    Rodbard, D

    1988-10-01

    The 'sandwich' or noncompetitive reagent-excess, 2-site immunoradiometric assay (2-site IRMA), ELISA, USERIA, and related techniques, have several advantages compared with the traditional or competitive radioimmunoassays. IRMAs can provide improved sensitivity and specificity. However, IRMAs present some practical problems with nonspecific binding, increased consumption of antibody, biphasic dose response curve, (high dose hook effect), and may require special techniques for dose response curve analysis. We anticipate considerable growth in the popularity and importance of 2-site IRMA.

  20. Development of monoclonal antibodies and quantitative ELISAs targeting insulin-degrading enzyme

    Directory of Open Access Journals (Sweden)

    Dickson Dennis W

    2009-10-01

    Full Text Available Abstract Background Insulin-degrading enzyme (IDE is a widely studied zinc-metalloprotease implicated in the pathogenesis of type 2 diabetes mellitus, Alzheimer disease (AD and varicella zoster virus infection. Despite more than six decades of research on IDE, progress has been hampered by the lack of well-characterized reagents targeting this biomedically important protease. To address this important need, we generated and characterized new mouse monoclonal antibodies (mAbs targeting natively folded human and rodent IDE. Results Eight monoclonal hybridoma cell lines were derived in house from mice immunized with full-length, natively folded, recombinant human IDE. The mAbs derived from these lines were shown to detect IDE selectively and sensitively by a wide range of methods. Two mAbs in particular—designated 6A1 and 6H9—proved especially selective for IDE in immunocytochemical and immunohistochemical applications. Using a variety of methods, we show that 6A1 selectively detects both human and rodent IDE, while 6H9 selectively detects human, but not rodent, IDE, with both mAbs showing essentially no cross reactivity with other proteins in these applications. Using these novel anti-IDE mAbs, we also developed sensitive and quantitative sandwich ELISAs capable of quantifying IDE levels present in human brain extracts. Conclusion We succeeded in developing novel mAbs that selectively detect rodent and/or human IDE, which we have shown to be suitable for a wide range of applications, including western blotting, immunoprecipitation, immunocytochemistry, immunohistochemistry, and quantitative sandwich ELISAs. These novel anti-IDE mAbs and the assays derived from them constitute important new tools for addressing many unresolved questions about the basic biology of IDE and its role in multiple highly prevalent human diseases.

  1. Development of a monoclonal antibody against the left wing of ciguatoxin CTX1B: thiol strategy and detection using a sandwich ELISA.

    Science.gov (United States)

    Tsumuraya, Takeshi; Takeuchi, Katsutoshi; Yamashita, Shuji; Fujii, Ikuo; Hirama, Masahiro

    2012-09-01

    Ciguatera fish poisoning (CFP) is a form of food poisoning caused by the ingestion of a variety of reef fish that have accumulated trace amounts of ciguatoxins produced by dinoflagellates of the genus Gambierdiscus through the food chain. CFP affects more than 50,000 people each year. The extremely low level of the causative neurotoxins, ciguatoxins, in fish has hampered the preparation of antibodies for detecting the toxins. In this paper, we describe a thiol strategy for synthesizing a keyhole limpet hemocyanin (KLH)-conjugate (20) of the ABCDE-ring fragment of the Pacific ciguatoxins, CTX1B (1) and 54-deoxyCTX1B (4). We succeeded in producing a monoclonal antibody (3G8) against the left wings of these ciguatoxins by immunizing mice with the hapten-KLH conjugate (20) as the synthetic antigen. The most promising mAb, 3G8, does not cross-react with other related marine toxins. Sandwich enzyme-linked immunosorbent assay (ELISA) utilizing 3G8 and the previously prepared monoclonal antibody (8H4) enabled us to detect 1 specifically at less than 0.28 ng/mL. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Immunodiagnosis of Human Fascioliasis by an Enzyme-Linked Immunosorbent Assay (ELISA) and a Micro-ELISA

    OpenAIRE

    Carnevale, Silvana; Rodríguez, Mónica I.; Santillán, Graciela; Labbé, Jorge H.; Cabrera, Marta G.; Bellegarde, Enrique J.; Velásquez, Jorge N.; Trgovcic, Jorge E.; Guarnera, Eduardo A.

    2001-01-01

    Enzyme-linked immunosorbent assay (ELISA) and micro-ELISA were evaluated for their ability to detect anti-Fasciola hepatica antibodies in humans by using excretory-secretory antigen. The sensitivity of each method was 100%, but the specificity was 100% for ELISA and 97% for micro-ELISA. The micro-ELISA could be used as a screening assay and ELISA could be used as a confirmatory method for the serodiagnosis of human fascioliasis.

  3. A novel sandwich enzyme-linked immunosorbent assay with covalently bound monoclonal antibody and gold probe for sensitive and rapid detection of bovine β-lactoglobulin.

    Science.gov (United States)

    He, Shengfa; Li, Xin; Wu, Yong; Wu, Shandong; Wu, Zhihua; Yang, Anshu; Tong, Ping; Yuan, Juanli; Gao, Jinyan; Chen, Hongbing

    2018-06-01

    Bovine milk is a recognized allergenic food source with β-lactoglobulin (BLG) as its major allergen. Reliable detection of BLG epitopes can, therefore, be a useful marker for the presence of milk in processed food products, and for potential allergenicity. At the present, enzyme-linked immunosorbent assays (ELISA) for the detection of BLG are time-consuming and generally not specific to BLG IgE epitopes. In this study, the 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide-activated anti-BLG IgE epitope monoclonal antibody (mAb 1G9) was covalently bound onto the KOH-treated microtiter plate surface. Using this mAb-bound plate in sandwich combination with biotinylated anti-BLG polyclonal antibody-labeled gold nanoparticles, a linear dynamic range between 31.25 and 64 × 10 3  ng mL -1 with a limit of detection for BLG of 0.49 ng mL -1 was obtained, which is 32 times wider and 16 times more sensitive than conventional sandwich ELISA (sELISA). Total recovery of BLG in spiked food samples was found, without matrix effects. Also in partially hydrolyzed infant formulas, the allergenic BLG residues were detected quantitatively. Compared with conventional and commercial BLG detection sELISAs, our sELISA is reliable, highly BLG epitope-specific, user-friendly, and time-saving and allows accurate detection of potentially allergenic residues in different types of processed foods. This improved sELISA protocol can be easily extended to detect other well-identified and characterized food allergens. Graphical abstract IgE epitope mAb-bound plate in sandwich combination with gold probe for sensitive and rapid detection of bovine β-lactoglobulin and its potentially allergenic residues.

  4. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  5. Procollagen type I N-terminal propeptide (PINP) as an indicator of type I collagen metabolism: ELISA development, reference interval, and hypovitaminosis D induced hyperparathyroidism

    DEFF Research Database (Denmark)

    Orum, O; Hansen, M; Jensen, Charlotte Harken

    1996-01-01

    A sandwich enzyme-linked immunosorbent assay (ELISA) for quantification of the N-terminal propeptide of human procollagen type I (PINP) utilizing purified alpha 1-chain specific rabbit antibodies is described. The ELISA measured the content of the alpha 1-chain of PINP independent of the molecular....../mL, these values being significantly different from the normal range (p ELISA was superior to commercially available assays for PICP and osteocalcin in separation between healthy controls and patients with osteomalaci. Udgivelsesdato: 1996-Aug...

  6. Establishment of sandwich ELISA for soluble alpha-Klotho measurement: Age-dependent change of soluble alpha-Klotho levels in healthy subjects.

    Science.gov (United States)

    Yamazaki, Yuji; Imura, Akihiro; Urakawa, Itaru; Shimada, Takashi; Murakami, Junko; Aono, Yukiko; Hasegawa, Hisashi; Yamashita, Takeyoshi; Nakatani, Kimihiko; Saito, Yoshihiko; Okamoto, Nozomi; Kurumatani, Norio; Namba, Noriyuki; Kitaoka, Taichi; Ozono, Keiichi; Sakai, Tomoyuki; Hataya, Hiroshi; Ichikawa, Shoji; Imel, Erik A; Econs, Michael J; Nabeshima, Yo-Ichi

    2010-07-30

    Alpha-Klotho (alphaKl) regulates mineral metabolism such as calcium ion (Ca(2+)) and inorganic phosphate (Pi) in circulation. Defects in mice result in clinical features resembling disorders found in human aging. Although the importance of transmembrane-type alphaKl has been demonstrated, less is known regarding the physiological importance of soluble-type alphaKl (salphaKl) in circulation. The aims of this study were: (1) to establish a sandwich ELISA system enabling detection of circulating serum salphaKl, and (2) to determine reference values for salphaKl serum levels and relationship to indices of renal function, mineral metabolism, age and sex in healthy subjects. We successively developed an ELISA to measure serum salphaKl in healthy volunteers (n=142, males 66) of ages (61.1+/-18.5year). The levels (mean+/-SD) in these healthy control adults were as follows: total calcium (Ca; 9.46+/-0.41mg/dL), Pi (3.63+/-0.51mg/dL), blood urea nitrogen (BUN; 15.7+/-4.3mg/dL), creatinine (Cre; 0.69+/-0.14mg/dL), 1,25 dihydroxyvitamin D (1,25(OH)(2)D; 54.8+/-17.7pg/mL), intact parathyroid hormone (iPTH; 49.2+/-20.6pg/mL), calcitonin (26.0+/-12.3pg/mL) and intact fibroblast growth factor (FGF23; 43.8+/-17.6pg/mL). Serum levels of salphaKl ranged from 239 to 1266pg/mL (mean+/-SD; 562+/-146pg/mL) in normal adults. Although salphaKl levels were not modified by gender or indices of mineral metabolism, salphaKl levels were inversely related to Cre and age. However, salphaKl levels in normal children (n=39, males 23, mean+/-SD; 7.1+/-4.8years) were significantly higher (mean+/-SD; 952+/-282pg/mL) than those in adults (mean+/-SD; 562+/-146, Plevel was notably lower than those of age-matched controls. We established a detection system to measure human serum salphaKl for the first time. Age, Ca and Pi seem to influence serum salphaKl levels in a normal population. This detection system should be an excellent tool for investigating salphaKl functions in mineral metabolism. Copyright

  7. Sound-proof Sandwich Panel Design via Metamaterial Concept

    Science.gov (United States)

    Sui, Ni

    Sandwich panels consisting of hollow core cells and two face-sheets bonded on both sides have been widely used as lightweight and strong structures in practical engineering applications, but with poor acoustic performance especially at low frequency regime. Basic sound-proof methods for the sandwich panel design are spontaneously categorized as sound insulation and sound absorption. Motivated by metamaterial concept, this dissertation presents two sandwich panel designs without sacrificing weight or size penalty: A lightweight yet sound-proof honeycomb acoustic metamateiral can be used as core material for honeycomb sandwich panels to block sound and break the mass law to realize minimum sound transmission; the other sandwich panel design is based on coupled Helmholtz resonators and can achieve perfect sound absorption without sound reflection. Based on the honeycomb sandwich panel, the mechanical properties of the honeycomb core structure were studied first. By incorporating a thin membrane on top of each honeycomb core, the traditional honeycomb core turns into honeycomb acoustic metamaterial. The basic theory for such kind of membrane-type acoustic metamaterial is demonstrated by a lumped model with infinite periodic oscillator system, and the negative dynamic effective mass density for clamped membrane is analyzed under the membrane resonance condition. Evanescent wave mode caused by negative dynamic effective mass density and impedance methods are utilized to interpret the physical phenomenon of honeycomb acoustic metamaterials at resonance. The honeycomb metamaterials can extraordinarily improve low-frequency sound transmission loss below the first resonant frequency of the membrane. The property of the membrane, the tension of the membrane and the numbers of attached membranes can impact the sound transmission loss, which are observed by numerical simulations and validated by experiments. The sandwich panel which incorporates the honeycomb metamateiral as

  8. Comparative Diagnosis of Serum IgG1 and Coproantigen ELISA for Fasciolosis Detection of Goats in Mexico

    Science.gov (United States)

    Molina-Mendoza, Pedro; Hernández-Guzmán, Karina; Olivares-Pérez, Jaime; Sarracent-Pérez, Jorge; Zumaquero-Ríos, José

    2016-01-01

    The objective of present study was to determine the prevalence of natural caprine fasciolosis in the Mixteca region of Mexico using coproantigen and serum IgG1 ELISA tests for comparative purposes. A total of 1070 serum and faecal samples were analyzed for IgG1 antibodies and coproantigens, using ELISA with E/S products as antigen and a monoclonal antibody-based sandwich ELISA. Prevalence of 73.46% was found using the serological ELISA and a percentage of 77.20 was found for coproantigen ELISA. The diagnostic sensitivity and specificity for serum ELISA were 86.7% and 96.4%, and for the coproantigen ELISA they were 93.1% and 97.8%, respectively. The seropositive samples were further categorized as low, medium, or high positivity. Results show a great proportion of low and medium positive goats when the serum ELISA test was used. Correlation coefficients between coproantigens and seropositivity were statistically significant (P < 0.01) for low seropositivity (r = 0.93) and medium seropositivity (r = 0.84). The accuracy of faecal antigen ELISA was higher compared to indirect ELISA serological test. Two ELISAs were shown to be useful for demonstrating the current status of F. hepatica infection in the endemic areas and can be employed in studies on epidemiology as well as anthelmintics treatment for preventing economic loss and the risk of transmission to humans. PMID:27563665

  9. The conformal method and the conformal thin-sandwich method are the same

    International Nuclear Information System (INIS)

    Maxwell, David

    2014-01-01

    The conformal method developed in the 1970s and the more recent Lagrangian and Hamiltonian conformal thin-sandwich methods are techniques for finding solutions of the Einstein constraint equations. We show that they are manifestations of a single conformal method: there is a straightforward way to convert back and forth between the parameters for these methods so that the corresponding solutions of the Einstein constraint equations agree. The unifying idea is the need to clearly distinguish tangent and cotangent vectors to the space of conformal classes on a manifold, and we introduce a vocabulary for working with these objects without reference to a particular representative background metric. As a consequence of these conceptual advantages, we demonstrate how to strengthen previous near-CMC (constant mean curvature) existence and non-existence theorems for the original conformal method to include metrics with scalar curvatures that change sign. (paper)

  10. Structural and failure mechanics of sandwich composites

    CERN Document Server

    Carlsson, LA; Carlsson, Leif A

    2011-01-01

    Focusing on important deformation and failure modes of sandwich structures, this volume describes the mechanics behind fracture processes. The text also reviews test methods developed for the cr, structural integrity, and failure mechanisms of sandwich structures.

  11. ELISA for complexes between urokinase-type plasminogen activator and its receptor in lung cancer tissue extracts

    DEFF Research Database (Denmark)

    de Witte, H; Pappot, H; Brünner, N

    1997-01-01

    A sandwich-type ELISA has been developed for the assessment of complexes between urokinase-type plasminogen activator (uPA) and its receptor (uPAR) in extracts of squamous cell lung carcinomas. The assay is based on a combination of rabbit polyclonal anti-uPA antibodies and a biotinylated mouse...... anti-uPAR monoclonal antibody (MAb). The detection limit of the assay is approximately 0.5 fmol/ml. A linear dose-response is obtained with up to 40 fmol/ml of uPA:uPAR complexes, while uPA and uPAR separately do not cause any response in the ELISA. A buffer which has been used previously for optimal...... extraction of uPAR yields the highest amounts of uPA:uPAR complexes. Absorption of tumor extracts with anti-uPA or anti-uPAR MAbs results in a complete disappearance of the ELISA signal, demonstrating the specificity of the ELISA. The recovery of chemically cross-linked uPA:uPAR complexes added to tumor...

  12. A Colorimetric Enzyme-Linked Immunosorbent Assay (ELISA) Detection Platform for a Point-of-Care Dengue Detection System on a Lab-on-Compact-Disc

    Science.gov (United States)

    Thiha, Aung; Ibrahim, Fatimah

    2015-01-01

    The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings. PMID:25993517

  13. A Colorimetric Enzyme-Linked Immunosorbent Assay (ELISA) Detection Platform for a Point-of-Care Dengue Detection System on a Lab-on-Compact-Disc.

    Science.gov (United States)

    Thiha, Aung; Ibrahim, Fatimah

    2015-05-18

    The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings.

  14. Detection of Antibodies to U.S. Isolates of Avian Pneumovirus by a Recombinant Nucleocapsid Protein-Based Sandwich Enzyme-Linked Immunosorbent Assay

    OpenAIRE

    Gulati, Baldev R.; Munir, Shirin; Patnayak, Devi P.; Goyal, Sagar M.; Kapur, Vivek

    2001-01-01

    The nucleocapsid (N) protein of subgroup C (United States-specific) avian pneumovirus (APV/US) was expressed in Escherichia coli, and antibodies to the recombinant N protein were shown to specifically recognize the ≈47-kDa N protein of APV/US by Western immunoblot analysis. The recombinant APV/US N protein was used in a sandwich-capture enzyme-linked immunosorbent assay (ELISA), and the resulting assay was found to be more sensitive and specific than the routine indirect ELISA for the detecti...

  15. Evaluation of methods to reduce background using the Python-based ELISA_QC program.

    Science.gov (United States)

    Webster, Rose P; Cohen, Cinder F; Saeed, Fatima O; Wetzel, Hanna N; Ball, William J; Kirley, Terence L; Norman, Andrew B

    2018-05-01

    Almost all immunological approaches [immunohistochemistry, enzyme-linked immunosorbent assay (ELISA), Western blot], that are used to quantitate specific proteins have had to address high backgrounds due to non-specific reactivity. We report here for the first time a quantitative comparison of methods for reduction of the background of commercial biotinylated antibodies using the Python-based ELISA_QC program. This is demonstrated using a recombinant humanized anti-cocaine monoclonal antibody. Several approaches, such as adjustment of the incubation time and the concentration of blocking agent, as well as the dilution of secondary antibodies, have been explored to address this issue. In this report, systematic comparisons of two different methods, contrasted with other more traditional methods to address this problem are provided. Addition of heparin (HP) at 1 μg/ml to the wash buffer prior to addition of the secondary biotinylated antibody reduced the elevated background absorbance values (from a mean of 0.313 ± 0.015 to 0.137 ± 0.002). A novel immunodepletion (ID) method also reduced the background (from a mean of 0.331 ± 0.010 to 0.146 ± 0.013). Overall, the ID method generated more similar results at each concentration of the ELISA standard curve to that using the standard lot 1 than the HP method, as analyzed by the Python-based ELISA_QC program. We conclude that the ID method, while more laborious, provides the best solution to resolve the high background seen with specific lots of biotinylated secondary antibody. Copyright © 2018. Published by Elsevier B.V.

  16. An enzyme-linked immunosorbent assay (ELISA) for quantification of mouse surfactant protein D (SP-D)

    DEFF Research Database (Denmark)

    Hansen, Soren; Schmidt, Vivi; Steffensen, Maria Abildgaard

    2008-01-01

    characterized and validated for use in sandwich enzyme-linked immunosorbent assay (ELISA). Based on two of these, we established an ELISA that allows for measurements of mouse SP-D in various body fluids. The final ELISA was optimized and calibrated with a standard of purified recombinant mouse SP-D, which......Surfactant protein D (SP-D) is a pattern recognition molecule of the collectin family of C-type lectins. It is found in the airways and at mucosal surfaces. SP-D is part of the innate immune system where it neutralizes and leads to elimination of microorganisms. It regulates the functions of other...... innate immune cells, such as macrophages and neutrophils. It also modulates the adaptive immune response by interacting with antigen-presenting cells and T cells. Monoclonal anti-mouse-SP-D antibodies were raised from SP-D deficient mice using recombinant SP-D as antigen. Ten monoclonal antibodies were...

  17. Comparison of viral RNA electrophoresis and indirect ELISA methods in the diagnosis of human rotavirus infection

    International Nuclear Information System (INIS)

    Avendano, L.F.; Dubinovsky, S.

    1984-01-01

    A total of 177 stool samples from Chilean diarrhea patients under two years of age were tested for rotavirus by two methods - the indirect enzyme-linked immunosorbent assay (indirect ELISA) and viral RNA electrophoresis in agarose gels (v RNA EPH). Fifty of the specimens came from patients with acute diarrhea and 127 came from patients with protracted diarrhea. The indirect ELISA testing was performed at the National Institutes of Health in the United States: the electrophoretic testing was carried out in Santiago, Chile by the authors. The electrophoretic method detected rotavirus in 36% of the acute samples and 25% of the samples from protracted cases, while the indirect ELISA method detected rotavirus in higher percentages of samples - 46% and 38%, respectively. These results support the conclusion that v RNA EPH is a less sensitive method for detecting rotavirus than the indirect ELISA. Nevertheless, the former method's high specificity, ease of application, and low cost make it a worthwhile alternative to indirect ELISA. Thus, considering the important role played by rotavirus in infant diarrhea and the need for a diagnostic technique that can be incorporated into the routines of medical center laboratories in developing countries, there is good reason to conclude that v RNA EPH is a useful tool for studying rotavirus diarrhea. (author)

  18. AN ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA) METHOD FOR MONITORING 2,4 DICHLOROPHENOXYACETIC ACID (2,4-D) EXPOSURES

    Science.gov (United States)

    Abstract describes a streamlined ELISA method developed to quantitatively measure 2,4-D in human urine samples. Method development steps and comparison with gas chromatography/mass spectrometry are presented. Results indicated that the ELISA method could be used as a high throu...

  19. Quantitative Detection of Horse Contamination in Cooked Meat Products by ELISA.

    Science.gov (United States)

    Thienes, Cortlandt P; Masiri, Jongkit; Benoit, Lora A; Barrios-Lopez, Brianda; Samuel, Santosh A; Cox, David P; Dobritsa, Anatoly P; Nadala, Cesar; Samadpour, Mansour

    2018-05-01

    Concerns about the contamination of meat products with horse meat and new regulations for the declaration of meat adulterants have highlighted the need for a rapid test to detect horse meat adulteration. To address this need, Microbiologique, Inc., has developed a sandwich ELISA that can quantify the presence of horse meat down to 0.1% (w/w) in cooked pork, beef, chicken, goat, and lamb meats. This horse meat authentication ELISA has an analytical sensitivity of 0.000030 and 0.000046% (w/v) for cooked and autoclaved horse meat, respectively, and an analytical range of quantitation of 0.05-0.8% (w/v) in the absence of other meats. The assay is rapid and can be completed in 1 h and 10 min. Moreover, the assay is specific for cooked horse meat and does not demonstrate any cross-reactivity with xenogeneic cooked meat sources.

  20. The Diagnostic Value of ELISA Method for Pertussis in Children

    Directory of Open Access Journals (Sweden)

    O. P. Popova

    2016-01-01

    Full Text Available Because of low effectiveness of laboratory methods for diagnosing pertussis it is important to look for new ways of verification of this infection. The article presents the analysis of the diagnostic value of ELISA method, which involves the identification of antibodies of different isotypes (IgM, IgG, IgA to pertussis toxoid (PT and filamentous haemagglutinin (FHA. The study included 279 children: 114 were under 1 year of age, 165 — older than 1 year. The pertussis was confirmed in 74.3 ± 2.6% of patients by using ELISA method. A significant proportion of seronegative patients (46.1 ± 6.2 per cent was revealed in the group of patients under 1 year. The pattern of production of antibodies in unvaccinated children was different. It depended on the age of the children and timing of illness. A low proportion of diagnostically significant indicators of IgM-antibodies at 2—3 weeks of illness was typical for patients under 1 year of age (e.g. 6.7 ± 6.5% as compared to 20.0 ± 7.9% and 50.0 ± 15.3 — 1—3 and 4—6 years of age. The diagnosis of pertussis in children under 1 year of age was confirmed mainly by the detection of IgG, starting from the 4th week of the disease. In the examination of vaccinated children diagnostically significant levels of IgA and IgG were identified (even in the late stages of the disease. Thus, the results of the analysis show special significance of using ELISA method for the diagnosis of pertussis in vaccinated children.

  1. Comparison of new immunofluorescence method for detection of soy protein in meat products with immunohistochemical, histochemical, and ELISA methods

    Directory of Open Access Journals (Sweden)

    Michaela Petrášová

    2014-01-01

    Full Text Available Soy proteins are commonly used in the food industry thanks to their technological properties. However, soy is, along with cow’s milk, eggs, wheat, peanuts, tree nuts, fish, crustaceans, and molluscs, responsible for around 90% of food allergies, and is also one of the foodstuffs that can cause anaphylaxis. The aim of this work was to compare the immunofluorescence method for the detection of soy protein in meat products purchased from the retail market with other microscopic methods (immunohistochemical and histochemical, with the ELISA reference method and with the confirmatory results. Within the research, 127 meat products purchased in the retail network were examined using the immunofluorescence method used for the detection of soy protein. The method was compared to Enzyme-Linked ImmunoSorbent Assay (ELISA, immunohistochemical, and histochemical methods. According to McNemar’s test, non-compliance between the immunofluorescence method and immunohistochemical method was low. In addition, a significant difference between the fluorescence method and ELISA (P P < 0.01 was found. The immunofluorescence method was also compared with confirmatory results. According to McNemar’s test, non-compliance between the immunofluorescence method and confirmatory results was low. The results showed the possibilities of this new method to detect the content of soy protein in meat products.

  2. Development of an Aquaporin-4 Orthogonal Array of Particle-Based ELISA for Neuromyelitis Optica Autoantibodies Detection.

    Directory of Open Access Journals (Sweden)

    Francesco Pisani

    Full Text Available Serological markers of Nuromyelitis Optica (NMO, an autoimmune disorder of the central nervous system, are autoantibodies targeting the astrocytic water channel aquaporin-4 (AQP4. We have previously demonstrated that the main epitopes for these autoantibodies (AQP4-IgG are generated by the supramolecular arrangement of AQP4 tetramers into an Orthogonal Array of Particles (OAPs. Many tests have been developed to detect AQP4-IgG in patient sera but several procedural issues affect OAP assembly and consequently test sensitivity. To date, the protein based ELISA test shows the lowest sensitivity while representing a valid alternative to the more sensitive cell based assay (CBA, which, however, shows economic, technical and interpretation problems. Here we have developed a high perfomance ELISA in which native OAPs are used as the molecular target. To this aim a native size exclusion chromatography method has been developed to isolate integral, highly pure and AQP4-IgG-recognized OAPs from rat brain. These OAPs were immobilized and oriented on a plastic plate by a sandwich approach and 139 human sera were tested, including 67 sera from NMO patients. The OAP-ELISA showed a 99% specificity and a higher sensitivity (91% compared to the CBA test. A comparative analysis revealed an end-point titer three orders of magnitude higher than the commercial ELISA and six times higher than our in-house CBA test. We show that CNS-extracted OAPs are crucial elements in order to perform an efficient AQP4-IgG test and the OAP-ELISA developed represents a valid alternative to the CBA currently used.

  3. Multi-Laboratory Validation of Estrone (E1) ELISA Methods

    Science.gov (United States)

    This project is a round-robin evaluation of commercially available Enzyme-Linked Immunosorbent Assay (ELISA) technology to quantitatively or qualitatively measure the hormone estrone (E1) in combined animal feeding operation (CAFO) receiving streams. ELISA is meant to be a simpl...

  4. Validation of an enzyme-linked immunosorbent assay (ELISA) for the measurement of canine S100A12.

    Science.gov (United States)

    Heilmann, Romy M; Cranford, Shannon M; Ambrus, Andy; Grützner, Niels; Schellenberg, Stefan; Ruaux, Craig G; Suchodolski, Jan S; Steiner, Jörg M

    2016-03-01

    Canine S100 calcium-binding protein A12 (cS100A12) shows promise as biomarker of inflammation in dogs. A previously developed cS100A12-radioimmunoassay (RIA) requires radioactive tracers and is not sensitive enough for fecal cS100A12 concentrations in 79% of tested healthy dogs. An ELISA assay may be more sensitive than RIA and does not require radioactive tracers. The purpose of the study was to establish a sandwich ELISA for serum and fecal cS100A12, and to establish reference intervals (RI) for normal healthy canine serum and feces. Polyclonal rabbit anti-cS100A12 antibodies were generated and tested by Western blotting and immunohistochemistry. A sandwich ELISA was developed and validated, including accuracy and precision, and agreement with cS100A12-RIA. The RI, stability, and biologic variation in fecal cS100A12, and the effect of corticosteroids on serum cS100A12 were evaluated. Lower detection limits were 5 μg/L (serum) and 1 ng/g (fecal), respectively. Intra- and inter-assay coefficients of variation were ≤ 4.4% and ≤ 10.9%, respectively. Observed-to-expected ratios for linearity and spiking recovery were 98.2 ± 9.8% (mean ± SD) and 93.0 ± 6.1%, respectively. There was a significant bias between the ELISA and the RIA. The RI was 49-320 μg/L for serum and 2-484 ng/g for fecal cS100A12. Fecal cS100A12 was stable for 7 days at 23, 4, -20, and -80°C; biologic variation was negligible but variation within one fecal sample was significant. Corticosteroid treatment had no clinically significant effect on serum cS100A12 concentrations. The cS100A12-ELISA is a precise and accurate assay for serum and fecal cS100A12 in dogs. © 2016 American Society for Veterinary Clinical Pathology.

  5. Novel indirect enzyme-linked immunosorbent assay (ELISA) method to detect Total E. coli in water environment

    International Nuclear Information System (INIS)

    Wang Na; He Miao; Shi Hanchang

    2007-01-01

    In order to establish ELISA (enzyme-linked immunosorbent assay) method to detect Total E. coli in water environment, E. coli multi-characters antigens in water environment were prepared according to the characters of kinds of E. coli serotypes, including antigen of whole cell, antigen of disrupted whole cell, somatic antigen, flagellar antigen and fimbrial antigen. Total E. coli polyclonal antibodies were obtained from the New Zealand rabbits immunized with these five antigens, respectively. Antibodies generated in this research are with high titers and good purity, can conjugate with antigens, specifically, stably and strongly. Indirect ELISA shows the titers of antibody of whole cell and antibody of disrupted whole cell are both over 1 x 10 5 . The cross-reactivity of the antibody is from 12 to 30% which indicate the specificity of the antibody against Total E. coli. Based on these antibodies, we established indirect ELISA method to detect Total E. coli in water environment. The matrix effects were studied and the results show that there is no significant influence by all the factors. The ELISA result shows that the detection limitation could be 10 4 CFU (colony forming units) L -1 . The indirect ELISA method developed in this study is well suited for Total E. coli analysis in real water samples as a rapid screen method

  6. Comparison of viral RNA electrophoresis and indirect ELISA methods in the diagnosis of human rotavirus infection

    Energy Technology Data Exchange (ETDEWEB)

    Avendano, L F; Dubinovsky, S; James, Jr, H D

    1984-01-01

    A total of 177 stool samples from Chilean diarrhea patients under two years of age were tested for rotavirus by two methods - the indirect enzyme-linked immunosorbent assay (indirect ELISA) and viral RNA electrophoresis in agarose gels (v RNA EPH). Fifty of the specimens came from patients with acute diarrhea and 127 came from patients with protracted diarrhea. The indirect ELISA testing was performed at the National Institutes of Health in the United States: the electrophoretic testing was carried out in Santiago, Chile by the authors. The electrophoretic method detected rotavirus in 36% of the acute samples and 25% of the samples from protracted cases, while the indirect ELISA method detected rotavirus in higher percentages of samples - 46% and 38%, respectively. These results support the conclusion that v RNA EPH is a less sensitive method for detecting rotavirus than the indirect ELISA. Nevertheless, the former method's high specificity, ease of application, and low cost make it a worthwhile alternative to indirect ELISA. Thus, considering the important role played by rotavirus in infant diarrhea and the need for a diagnostic technique that can be incorporated into the routines of medical center laboratories in developing countries, there is good reason to conclude that v RNA EPH is a useful tool for studying rotavirus diarrhea. 18 refs, 3 tabs. Also published in the Bol. Oficina Sanit. Panam. (1984) v. 97(1), p. 1-7 (In Spanish).

  7. Rubella virus detection by ELISA method in exposed radiation workers

    International Nuclear Information System (INIS)

    Wu Jianmei; Zhu Bo; Zhu Youming; Shao Jinhui; Wu Weiping; Han Jinxiang

    2005-01-01

    Objective: A rapid diagnosis method was developed to detect Rubella virus infection in radiation workers. Methods: Modified ELISA method was used to detect the level of lgG and lgM antibodies in 514 in Jinan district. Results: 90.47% of 514 cases was shown to be resistant against Rubella virus; 6.42% were sensitive type; 0.78% belonged to be reinfected. Conclusion: Detection of Rubella virus in exposed radiation workers was imperative, and vaccine against Rubella virus was also needed to eliminate the infection risk. (authors)

  8. Sandwich mapping of schistosomiasis risk in Anhui Province, China.

    Science.gov (United States)

    Hu, Yi; Bergquist, Robert; Lynn, Henry; Gao, Fenghua; Wang, Qizhi; Zhang, Shiqing; Li, Rui; Sun, Liqian; Xia, Congcong; Xiong, Chenglong; Zhang, Zhijie; Jiang, Qingwu

    2015-06-03

    Schistosomiasis mapping using data obtained from parasitological surveys is frequently used in planning and evaluation of disease control strategies. The available geostatistical approaches are, however, subject to the assumption of stationarity, a stochastic process whose joint probability distribution does not change when shifted in time. As this is impractical for large areas, we introduce here the sandwich method, the basic idea of which is to divide the study area (with its attributes) into homogeneous subareas and estimate the values for the reporting units using spatial stratified sampling. The sandwich method was applied to map the county-level prevalence of schistosomiasis japonica in Anhui Province, China based on parasitological data collected from sample villages and land use data. We first mapped the county-level prevalence using the sandwich method, then compared our findings with block Kriging. The sandwich estimates ranged from 0.17 to 0.21% with a lower level of uncertainty, while the Kriging estimates varied from 0 to 0.97% with a higher level of uncertainty, indicating that the former is more smoothed and stable compared to latter. Aside from various forms of reporting units, the sandwich method has the particular merit of simple model assumption coupled with full utilization of sample data. It performs well when a disease presents stratified heterogeneity over space.

  9. Development of monoclonal antibodies against Sj29 and its possible application for schistosomiasis diagnosis

    Directory of Open Access Journals (Sweden)

    Cui-Ping Ren

    2017-08-01

    Conclusions: Sj29 double antibody sandwich ELISA was established. The specificity of this method for detecting healthy sera was 100%. Meanwhile, Sj29 sandwich ELISA may have a potential diagnostic capability to distinguish current from past infections and assess drug treatment responses.

  10. A Sandwich HIV p24 Amperometric Immunosensor Based on a Direct Gold Electroplating-Modified Electrode

    Directory of Open Access Journals (Sweden)

    Ning Gan

    2012-05-01

    Full Text Available Acquired immune deficiency syndrome (AIDS is a severe communicable immune deficiency disease caused by the human immune deficiency virus (HIV. The analysis laboratory diagnosis of HIV infection is a crucial aspect of controlling AIDS. The p24 antigen, the HIV-1 capsid protein, is of considerable diagnostic interest because it is detectable several days earlier than host-generated HIV antibodies following HIV exposure. We present herein a new sandwich HIV p24 immunosensor based on directly electroplating an electrode surface with gold nanoparticles using chronoamperometry, which greatly increased the conductivity and reversibility of the electrode. Under optimum conditions, the electrochemical signal showed a linear relationship with the concentration of p24, ranging from 0.01 ng/mL to 100 ng/mL (R > 0.99, and the detection limit was 0.008 ng/mL. Compared with ELISA, this method increased the sensitivity by more than two orders of magnitude (the sensitivity of ELISA for p24 is about 1 ng/mL. This immunosensor may be broadly applied to clinical samples, being distinguished by its ease of use, mild reaction conditions, guaranteed reproducibility, and good anti-interference ability.

  11. A sandwich HIV p24 amperometric immunosensor based on a direct gold electroplating-modified electrode.

    Science.gov (United States)

    Zheng, Lei; Jia, Liyong; Li, Bo; Situ, Bo; Liu, Qinlan; Wang, Qian; Gan, Ning

    2012-05-18

    Acquired immune deficiency syndrome (AIDS) is a severe communicable immune deficiency disease caused by the human immune deficiency virus (HIV). The analysis laboratory diagnosis of HIV infection is a crucial aspect of controlling AIDS. The p24 antigen, the HIV-1 capsid protein, is of considerable diagnostic interest because it is detectable several days earlier than host-generated HIV antibodies following HIV exposure. We present herein a new sandwich HIV p24 immunosensor based on directly electroplating an electrode surface with gold nanoparticles using chronoamperometry, which greatly increased the conductivity and reversibility of the electrode. Under optimum conditions, the electrochemical signal showed a linear relationship with the concentration of p24, ranging from 0.01 ng/mL to 100 ng/mL (R > 0.99), and the detection limit was 0.008 ng/mL. Compared with ELISA, this method increased the sensitivity by more than two orders of magnitude (the sensitivity of ELISA for p24 is about 1 ng/mL). This immunosensor may be broadly applied to clinical samples, being distinguished by its ease of use, mild reaction conditions, guaranteed reproducibility, and good anti-interference ability.

  12. Optimization of composite sandwich cover panels subjected to compressive loadings

    Science.gov (United States)

    Cruz, Juan R.

    1991-01-01

    An analysis and design method is presented for the design of composite sandwich cover panels that include the transverse shear effects and damage tolerance considerations. This method is incorporated into a sandwich optimization computer program entitled SANDOP. As a demonstration of its capabilities, SANDOP is used in the present study to design optimized composite sandwich cover panels for for transport aircraft wing applications. The results of this design study indicate that optimized composite sandwich cover panels have approximately the same structural efficiency as stiffened composite cover panels designed to satisfy individual constraints. The results also indicate that inplane stiffness requirements have a large effect on the weight of these composite sandwich cover panels at higher load levels. Increasing the maximum allowable strain and the upper percentage limit of the 0 degree and +/- 45 degree plies can yield significant weight savings. The results show that the structural efficiency of these optimized composite sandwich cover panels is relatively insensitive to changes in core density. Thus, core density should be chosen by criteria other than minimum weight (e.g., damage tolerance, ease of manufacture, etc.).

  13. Quantification in mass units of group 1 grass allergens by a monoclonal antibody-based sandwich ELISA.

    Science.gov (United States)

    Arilla, M C; Ibarrola, I; Eraso, E; Aguirre, M; Martínez, A; Asturias, J A

    2001-08-01

    Grass pollen extracts currently used for allergy diagnosis and immunotherapy are a complex mixture of proteins of which only a few have allergenic activity. Lol p 1 is one of the most important allergens in grass pollen extracts. To develop a two-site enzyme-linked immunosorbent assay for the quantification of Lol p 1 and other group 1 allergens from grass species, and to assess its suitability for quantifying this group of allergens. Balb/c mice immunized with recombinant Lol p 1 were used for the production of monoclonal antibodies. Screening of hybridomas was performed by direct ELISA, and selected monoclonal antibodies were immobilized on ELISA plates and incubated with samples containing group 1 allergens. Bound allergens were detected by a combination of biotinylated Lol p 1-specific monoclonal antibody and peroxidase-streptavidin conjugate. The assay is based on three Lol p 1-specific monoclonal antibodies with different epitope specificities. The optimized ELISA measured Lol p 1 concentrations ranging from 125 to 1000 ng/mL and could quantify group 1 allergen from grass species belonging to the Pooidea subfamily. The assay does not depend on anti-sera production or availability of human sera and thus reactives can be produced in unlimited amounts. This sensitive and specific Lol p 1 assay will be helpful both for quantifying the group 1 allergen content of Pooideae pollen extracts intended for clinical use and for studying cross-reactivities among pollen extracts.

  14. Research on a Novel Exciting Method for a Sandwich Transducer Operating in Longitudinal-Bending Hybrid Modes

    Directory of Open Access Journals (Sweden)

    Yingxiang Liu

    2017-06-01

    Full Text Available A novel exciting method for a sandwich type piezoelectric transducer operating in longitudinal-bending hybrid vibration modes is proposed and discussed, in which the piezoelectric elements for the excitations of the longitudinal and bending vibrations share the same axial location, but correspond to different partitions. Whole-piece type piezoelectric plates with three separated partitions are used, in which the center partitions generate the first longitudinal vibration, while the upper and lower partitions produce the second bending vibration. Detailed comparisons between the proposed exciting method and the traditional one were accomplished by finite element method (FEM calculations, which were further verified by experiments. Compared with the traditional exciting method using independent longitudinal ceramics and bending ceramics, the proposed method achieves higher electromechanical coupling factors and larger vibration amplitudes, especially for the bending vibration mode. This novel exciting method for longitudinal-bending hybrid vibrations has not changed the structural dimensions of the sandwich transducer, but markedly improves the mechanical output ability, which makes it very helpful and meaningful in designing new piezoelectric actuators operated in longitudinal-bending hybrid vibration modes.

  15. SIGNS The sandwich sign

    African Journals Online (AJOL)

    The sandwich sign is demonstrated on cross-sectional imaging, commonly on CT or ultrasound. It refers to homogeneous soft- tissue masses representing mesenteric lymphadenopathy as the two halves of a sandwich bun, encasing the mesenteric fat and tubular mesenteric vessels that constitute the 'sandwich filling' (Figs ...

  16. Iodoacetyl-functionalized pullulan: A supplemental enhancer for single-domain antibody-polyclonal antibody sandwich enzyme-linked immunosorbent assay for detection of survivin.

    Science.gov (United States)

    Matsushita, Takahiko; Arai, Hidenao; Koyama, Tetsuo; Hatano, Ken; Nemoto, Naoto; Matsuoka, Koji

    2017-11-01

    Survivin, an inhibitor of the apoptosis protein family, is a potent tumor marker for diagnosis and prognosis. The enzyme-linked immunosorbent assay (ELISA) is one of the methods that has been used for detection of survivin. However, ELISA has several disadvantages caused by the use of conventional antibodies, and we have therefore been trying to develop a novel ELISA system using camelid single-domain antibodies (VHHs) as advantageous replacements. Here we report a supplemental approach to improve the VHH-polyclonal antibody sandwich ELISA for survivin detection. Iodoacetyl-functionalized pullulan was synthesized, and its thiol reactivity was characterized by a model reaction with l-cysteine. The thiophilic pullulan was applied to an immunoassay asan additive upon coating of standard assay plates with an anti-survivin VHH fusion protein with C-terminal cysteine. The results showed that the mole ratio of the additive to VHH had a significant effect on the consequent response. Mole ratios of 0.07, 0.7, and 7 led to 90% lower, 15% higher, and 69% lower responses, respectively, than the response of a positive control in which no additive was used. The background levels observed in any additive conditions were as low as that of a negative control lacking both VHH and the additive. These results indicate the applicability of the thiol-reactive pullulan as a response enhancer to VHH-based ELISA. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. A Monoclonal Antibody Based Capture ELISA for Botulinum Neurotoxin Serotype B: Toxin Detection in Food

    Directory of Open Access Journals (Sweden)

    Larry H. Stanker

    2013-11-01

    Full Text Available Botulism is a serious foodborne neuroparalytic disease, caused by botulinum neurotoxin (BoNT, produced by the anaerobic bacterium Clostridium botulinum. Seven toxin serotypes (A–H have been described. The majority of human cases of botulism are caused by serotypes A and B followed by E and F. We report here a group of serotype B specific monoclonal antibodies (mAbs capable of binding toxin under physiological conditions. Thus, they serve as capture antibodies for a sandwich (capture ELISA. The antibodies were generated using recombinant peptide fragments corresponding to the receptor-binding domain of the toxin heavy chain as immunogen. Their binding properties suggest that they bind a complex epitope with dissociation constants (KD’s for individual antibodies ranging from 10 to 48 × 10−11 M. Assay performance for all possible combinations of capture-detector antibody pairs was evaluated and the antibody pair resulting in the lowest level of detection (L.O.D., ~20 pg/mL was determined. Toxin was detected in spiked dairy samples with good recoveries at concentrations as low as 0.5 pg/mL and in ground beef samples at levels as low as 2 ng/g. Thus, the sandwich ELISA described here uses mAb for both the capture and detector antibodies (binding different epitopes on the toxin molecule and readily detects toxin in those food samples tested.

  18. A monoclonal antibody based capture ELISA for botulinum neurotoxin serotype B: toxin detection in food.

    Science.gov (United States)

    Stanker, Larry H; Scotcher, Miles C; Cheng, Luisa; Ching, Kathryn; McGarvey, Jeffery; Hodge, David; Hnasko, Robert

    2013-11-18

    Botulism is a serious foodborne neuroparalytic disease, caused by botulinum neurotoxin (BoNT), produced by the anaerobic bacterium Clostridium botulinum. Seven toxin serotypes (A-H) have been described. The majority of human cases of botulism are caused by serotypes A and B followed by E and F. We report here a group of serotype B specific monoclonal antibodies (mAbs) capable of binding toxin under physiological conditions. Thus, they serve as capture antibodies for a sandwich (capture) ELISA. The antibodies were generated using recombinant peptide fragments corresponding to the receptor-binding domain of the toxin heavy chain as immunogen. Their binding properties suggest that they bind a complex epitope with dissociation constants (KD's) for individual antibodies ranging from 10 to 48 × 10-11 M. Assay performance for all possible combinations of capture-detector antibody pairs was evaluated and the antibody pair resulting in the lowest level of detection (L.O.D.), ~20 pg/mL was determined. Toxin was detected in spiked dairy samples with good recoveries at concentrations as low as 0.5 pg/mL and in ground beef samples at levels as low as 2 ng/g. Thus, the sandwich ELISA described here uses mAb for both the capture and detector antibodies (binding different epitopes on the toxin molecule) and readily detects toxin in those food samples tested.

  19. Sandwich mapping of schistosomiasis risk in Anhui Province, China

    Directory of Open Access Journals (Sweden)

    Yi Hu

    2015-06-01

    Full Text Available Schistosomiasis mapping using data obtained from parasitological surveys is frequently used in planning and evaluation of disease control strategies. The available geostatistical approaches are, however, subject to the assumption of stationarity, a stochastic process whose joint probability distribution does not change when shifted in time. As this is impractical for large areas, we introduce here the sandwich method, the basic idea of which is to divide the study area (with its attributes into homogeneous subareas and estimate the values for the reporting units using spatial stratified sampling. The sandwich method was applied to map the county-level prevalence of schistosomiasis japonica in Anhui Province, China based on parasitological data collected from sample villages and land use data. We first mapped the county-level prevalence using the sandwich method, then compared our findings with block Kriging. The sandwich estimates ranged from 0.17 to 0.21% with a lower level of uncertainty, while the Kriging estimates varied from 0 to 0.97% with a higher level of uncertainty, indicating that the former is more smoothed and stable compared to latter. Aside from various forms of reporting units, the sandwich method has the particular merit of simple model assumption coupled with full utilization of sample data. It performs well when a disease presents stratified heterogeneity over space.

  20. Detection of HBsAg and Anti HBc on donors of a blood bank by IRMA and ELISA methods

    International Nuclear Information System (INIS)

    Freire Martinez, D.Y.

    1985-10-01

    Comparative evaluation of two methods, Immunoradiometric Assay (IRMA) and Enzyme Immunoassay (ELISA), for detecting HBsAg and Anti HBc was made for determining which is the most advantageous and reliable. The study was made on 300 donors of the Hospital San Juan de Dios Blood Bank. In comparison with the reference method (IRMA), ELISA shows 91.67% of sensitivity. The Anti HBc detection by IRMA is more reliable than the HBsAg detection by IRMA and ELISA for determining the carrier state

  1. Measuring Cohesive Laws for Interfaces in Sandwich Structures

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Sørensen, Bent F.; Berggreen, Carl Christian

    2006-01-01

    mixities. The sandwich specimens consists of glass fiber faces and Divinycell H200 foam core with a pre-crack between face and core made with teflon film. Arbitrary stiffening of the sandwich faces with steel bars adhered to the faces reduces rotations and ensures that the method is useable for a wide...

  2. DEVELOPMENT AND EVALUATION OF AN ENZYME-LINKED IMMUNOASSAY (ELISA) METHOD FOR THE MEASUREMENT OF 2,4-DICHLOROPHENOXYACETIC ACID IN HUMAN URINE

    Science.gov (United States)

    This paper describes the development of a 96-microwell high sample capacity ELISA method for measuring 2,4-D in urine; the analysis of 2,4-D in real-world urine samples by both ELISA and GC/MS methods; and compares the ELISA and GC/MS results in several key areas: accuracy, preci...

  3. Development of an ELISA for evaluation of swab recovery efficiencies of bovine serum albumin.

    Directory of Open Access Journals (Sweden)

    Nadja Sparding

    Full Text Available After a potential biological incident the sampling strategy and sample analysis are crucial for the outcome of the investigation and identification. In this study, we have developed a simple sandwich ELISA based on commercial components to quantify BSA (used as a surrogate for ricin with a detection range of 1.32-80 ng/mL. We used the ELISA to evaluate different protein swabbing procedures (swabbing techniques and after-swabbing treatments for two swab types: a cotton gauze swab and a flocked nylon swab. The optimal swabbing procedure for each swab type was used to obtain recovery efficiencies from different surface materials. The surface recoveries using the optimal swabbing procedure ranged from 0-60% and were significantly higher from nonporous surfaces compared to porous surfaces. In conclusion, this study presents a swabbing procedure evaluation and a simple BSA ELISA based on commercial components, which are easy to perform in a laboratory with basic facilities. The data indicate that different swabbing procedures were optimal for each of the tested swab types, and the particular swab preference depends on the surface material to be swabbed.

  4. Elisa Miller | NREL

    Science.gov (United States)

    Elisa Miller Photo of Elisa Miller Elisa Link-Miller Researcher III-Chemistry Elisa.Miller@nrel.gov | 303-384-6777 Dr. Elisa Miller-Link studies the surface of semiconductors that are applicable for , and other nanocrystalline films. Elisa came to NREL in 2013 as an NREL Director's Fellowship recipient

  5. EVALUATION OF ELISA METHOD TO DETECTION OF COW β-LACTOGLOBULIN IN SHEEP MILK AND SHEEP MILK PRODUCTS

    Directory of Open Access Journals (Sweden)

    Juraj Paulov

    2010-11-01

    Full Text Available The aim of work was to optimalize the ELISA method to detect the adulteration of sheep milk and sheep milk products by cow milk in the laboratory. We have focused on laboratory testing of ELISA kit (β-Lactoglobulin ELISA Set, SEDIUM R&D for detection of cow β-Lg in sheep milk order to obtain high-quality, reliable and economically advantageous method suitable for routine use in practice. The results shown that for the quality of adulteration determination  it is necessary to verify the sensitivity of applied kit by the samples dilution in accordance with the producer declared quantification range contained in the manual ELISA kit. The starting point for obtaining of relevant data was to create separate regression curves with high deter­mination coefficient, which allowed to quickly and easily detect the cow milk additions in sheep milk, cloddish sheep and Slovak sheep cheese. doi:10.5219/78  

  6. ELISA for detection of variant rabbit haemorrhagic disease virus RHDV2 antigen in liver extracts.

    Science.gov (United States)

    Dalton, K P; Podadera, A; Granda, V; Nicieza, I; Del Llano, D; González, R; de Los Toyos, J R; García Ocaña, M; Vázquez, F; Martín Alonso, J M; Prieto, J M; Parra, F; Casais, R

    2018-01-01

    The emergence and rapid spread of variant of the rabbit hemorrhagic disease virus (RHDV2) require new diagnostic tools to ensure that efficient control measures are adopted. In the present study, a specific sandwich enzyme-linked immunosorbent assay (ELISA) for detection of RHDV2 antigens in rabbit liver homogenates, based on the use of an RHDV2-specific monoclonal antibody (Mab) 2D9 for antigen capture and an anti-RHDV2 goat polyclonal antibody (Pab), was developed. This ELISA was able to successfully detect RHDV2 and RHDV2 recombinant virions with high sensitivity (100%) and specificity (97.22%). No cross-reactions were detected with RHDV G1 viruses while low cross-reactivity was detected with one of the RHDVa samples analyzed. The ELISA afforded good repeatability and had high analytical sensitivity as it was able to detect a dilution 1:163,640 (6.10ng/mL) of purified RHDV-N11 VLPs, which contained approximately 3.4×10 8 molecules/mL particles. The reliable discrimination between closely related viruses is crucial to understand the epidemiology and the interaction of co-existing pathogens. In the work described here we design and validate an ELISA for laboratory based, specific, sensitive and reliable detection of RHDVb/RHDV2. This ELISA is a valuable, specific virological tool for monitoring virus circulation, which will permit a better control of this disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. DPI-ELISA: a fast and versatile method to specify the binding of plant transcription factors to DNA in vitro

    Directory of Open Access Journals (Sweden)

    Chaban Christina

    2010-11-01

    Full Text Available Abstract Background About 10% of all genes in eukaryote genomes are predicted to encode transcription factors. The specific binding of transcription factors to short DNA-motifs influences the expression of neighbouring genes. However, little is known about the DNA-protein interaction itself. To date there are only a few suitable methods to characterise DNA-protein-interactions, among which the EMSA is the method most frequently used in laboratories. Besides EMSA, several protocols describe the effective use of an ELISA-based transcription factor binding assay e.g. for the analysis of human NFκB binding to specific DNA sequences. Results We provide a unified protocol for this type of ELISA analysis, termed DNA-Protein-Interaction (DPI-ELISA. Qualitative analyses with His-epitope tagged plant transcription factors expressed in E. coli revealed that EMSA and DPI-ELISA result in comparable and reproducible data. The binding of AtbZIP63 to the C-box and AtWRKY11 to the W2-box could be reproduced and validated by both methods. We next examined the physical binding of the C-terminal DNA-binding domains of AtWRKY33, AtWRKY50 and AtWRKY75 to the W2-box. Although the DNA-binding domain is highly conserved among the WRKY proteins tested, the use of the DPI-ELISA discloses differences in W2-box binding properties between these proteins. In addition to these well-studied transcription factor families, we applied our protocol to AtBPC2, a member of the so far uncharacterised plant specific Basic Pentacysteine transcription factor family. We could demonstrate binding to GA/TC-dinucleotide repeat motifs by our DPI-ELISA protocol. Different buffers and reaction conditions were examined. Conclusions We successfully applied our DPI-ELISA protocol to investigate the DNA-binding specificities of three different classes of transcription factors from Arabidopsis thaliana. However, the analysis of the binding affinity of any DNA-binding protein to any given DNA

  8. Comparison of radioimmunoassay and ELISA methods for detection of antibodies to chromatin components

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, E; Cheng, N [North Carolina Univ., Chapel Hill (USA). Dept. of Bacteriology and Immunology

    1983-09-16

    A solid phase radioimmunoassay has been compared with an enzyme-linked immunosorbent assay (ELISA) for efficacy in measuring anti-chromatin antibodies. The low backgrounds achieved with the radioimmunoassay method produced a high signal-to-noise ratio and enabled detection of the human test antiserum at a dilution of 1:102,400. By contrast, the ELISA could detect the same antiserum only at a dilution of 1;3200 and above. The radioimmunoassay was consistently more sensitive than the ELSIA for detection of anti-chromatin antibodies in a number of human and mouse sera and ascites fluid containing a monoclonal antibody. Factors affecting sensitivity in both assays are discussed.

  9. Fundamental study on reactivities of gluten protein types from wheat, rye and barley with five sandwich ELISA test kits.

    Science.gov (United States)

    Lexhaller, Barbara; Tompos, Christine; Scherf, Katharina Anne

    2017-12-15

    Monitoring the compliance of gluten-free foods to the regulatory threshold of 20mg/kg of gluten is essential for celiac disease patients. The different enzyme-linked immunosorbent assays (ELISAs) for gluten detection each have specific characteristics, but there are only a few systematic comparisons. This fundamental study compared the specificities and sensitivities of the R5, G12 and Skerritt monoclonal and two polyclonal antibodies to well-defined gluten protein types (GPT) isolated from wheat, rye and barley flours. Quantitation of protein concentrations by reversed-phase high-performance liquid chromatography provided independent reference values. The ELISA responses showed high variability depending on the type of cereal, the GPT and the antibody used. Overall, ω1,2-gliadins and γ-75k-secalins were most reactive, whereas ω5-gliadins and γ-, B- and D-hordeins were detected with the lowest sensitivities. These results revealed which GPT each antibody is most sensitive to and provided novel insights that will be helpful for appropriate calibration of ELISAs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. An enzyme-linked immunosorbent assay (ELISA) for quantification of human collectin 11 (CL-11, CL-K1)

    Science.gov (United States)

    Selman, L.; Henriksen, M.L.; Brandt, J.; Palarasah, Y.; Waters, A.; Beales, P.L.; Holmskov, U.; Jørgensen, T.J.D.; Nielsen, C.; Skjodt, K.; Hansen, S.

    2012-01-01

    Collectin 11 (CL-11), also referred to as collectin kidney 1 (CL-K1), is a pattern recognition molecule that belongs to the collectin group of proteins involved in innate immunity. It interacts with glycoconjugates on pathogen surfaces and has been found in complex with mannose-binding lectin-associated serine protease 1 (MASP-1) and/or MASP-3 in circulation. Mutation in the CL-11 gene was recently associated with the developmental syndrome 3MC. In the present study, we established and thoroughly validated a sandwich enzyme-linked immunosorbent assay (ELISA) based on two different monoclonal antibodies. The assay is highly sensitive, specific and shows excellent quantitative characteristics such as reproducibility, dilution linearity and recovery (97.7–104%). The working range is 0.15–34 ng/ml. The CL-11 concentration in two CL-11-deficient individuals affected by the 3MC syndrome was determined to be below 2.1 ng/ml. We measured the mean serum CL-11 concentration to 284 ng/ml in 100 Danish blood donors, with a 95% confidence interval of 269–299 ng/ml. There was no significant difference in the CL-11 concentration measured in matched serum and plasma samples. Storage of samples and repeated freezing and thawing to a certain extent did not influence the ELISA. This ELISA offers a convenient and reliable method for studying CL-11 levels in relation to a variety of human diseases and syndromes. PMID:22301270

  11. Universal quantum dot-based sandwich-like immunoassay strategy for rapid and ultrasensitive detection of small molecules using portable and reusable optofluidic nano-biosensing platform

    International Nuclear Information System (INIS)

    Zhou, Liping; Zhu, Anna; Lou, Xuening; Song, Dan; Yang, Rong; Shi, Hanchang; Long, Feng

    2016-01-01

    A universal sandwich-like immunoassay strategy based on quantum-dots immunoprobe (QD-labeled anti-mouse IgG antibody) was developed for rapid and ultrasensitive detection of small molecules. A portable and reusable optofluidic nano-biosensing platform was applied to investigate the sandwich-like immunoassay mechanism and format of small molecules, as well as the binding kinetics between QD immunoprobe and anti-small molecule antibody. A two-step immunoassay method that involves pre-incubation mixture of different concentration of small molecule and anti-small molecule antibody, and subsequent introduction of QD immunoprobe into the optofluidic cell was conducted for small molecule determination. Compared with the one-step immunoassay method, the two-step immunoassay method can obtain higher fluorescence signal and higher sensitivity index, thus improving the nano-biosensing performance. Based on the proposed strategy, two mode targets, namely, microcystin-LR (MC-LR) and Bisphenol A (BPA) were tested with high sensitivity, rapidity, and ease of use. A higher concentration of small molecules in the sample led to less anti-small molecule antibody bound with antigen-carrier protein conjugate immobilized onto the sensor surface, and less QD immunoprobes bound with anti-small molecule antibody. This phenomenon lowered the fluorescence signal detected by nano-biosensing platform. Under optimal operating conditions, MC-LR and BPA exhibited a limit of detection of 0.003 and 0.04 μg/L, respectively. The LODs were better than those of the indirect competitive immunoassay method for small molecules via Cy5.5-labeled anti-small molecule antibody. The proposed QD-based sandwich-like immunoassay strategy was evaluated in spiked water samples, and showed good recovery, precision and accuracy without complicated sample pretreatments. All these results demonstrate that the new detection strategy could be readily applied to the other trace small molecules in real water samples

  12. Universal quantum dot-based sandwich-like immunoassay strategy for rapid and ultrasensitive detection of small molecules using portable and reusable optofluidic nano-biosensing platform

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Liping; Zhu, Anna; Lou, Xuening; Song, Dan; Yang, Rong [School of Environment and Natural Resources, Renmin University of China, Beijing (China); Shi, Hanchang [School of Environment, Tsinghua University, Beijing (China); Long, Feng, E-mail: longf04@ruc.edu.cn [School of Environment and Natural Resources, Renmin University of China, Beijing (China)

    2016-01-28

    A universal sandwich-like immunoassay strategy based on quantum-dots immunoprobe (QD-labeled anti-mouse IgG antibody) was developed for rapid and ultrasensitive detection of small molecules. A portable and reusable optofluidic nano-biosensing platform was applied to investigate the sandwich-like immunoassay mechanism and format of small molecules, as well as the binding kinetics between QD immunoprobe and anti-small molecule antibody. A two-step immunoassay method that involves pre-incubation mixture of different concentration of small molecule and anti-small molecule antibody, and subsequent introduction of QD immunoprobe into the optofluidic cell was conducted for small molecule determination. Compared with the one-step immunoassay method, the two-step immunoassay method can obtain higher fluorescence signal and higher sensitivity index, thus improving the nano-biosensing performance. Based on the proposed strategy, two mode targets, namely, microcystin-LR (MC-LR) and Bisphenol A (BPA) were tested with high sensitivity, rapidity, and ease of use. A higher concentration of small molecules in the sample led to less anti-small molecule antibody bound with antigen-carrier protein conjugate immobilized onto the sensor surface, and less QD immunoprobes bound with anti-small molecule antibody. This phenomenon lowered the fluorescence signal detected by nano-biosensing platform. Under optimal operating conditions, MC-LR and BPA exhibited a limit of detection of 0.003 and 0.04 μg/L, respectively. The LODs were better than those of the indirect competitive immunoassay method for small molecules via Cy5.5-labeled anti-small molecule antibody. The proposed QD-based sandwich-like immunoassay strategy was evaluated in spiked water samples, and showed good recovery, precision and accuracy without complicated sample pretreatments. All these results demonstrate that the new detection strategy could be readily applied to the other trace small molecules in real water samples

  13. A new ELISA for the quantification of equine procalcitonin in plasma as potential inflammation biomarker in horses.

    Science.gov (United States)

    Rieger, Martin; Kochleus, Christian; Teschner, Dana; Rascher, Daniela; Barton, Ann Kristin; Geerlof, Arie; Kremmer, Elisabeth; Schmid, Michael; Hartmann, Anton; Gehlen, Heidrun

    2014-09-01

    In human medicine, procalcitonin (PCT) is a very common and well-established biomarker for sepsis. Even though sepsis is also a leading cause of death in foals and adult horses, up to now, no data about the role of equine PCT in septic horses has been available. Based on monoclonal antibodies targeted against human PCT, we report here the development of a sandwich ELISA for the quantification of equine PCT in equine plasma samples. The ELISA was characterized for intra- and interassay variance and a working range from 25 to 1,000 ng mL(-1) was defined as within this range; both intra- and interassay variances were below 15 %. The target recovery ranged between 73 and 106 %. The ELISA was used to determine the equine PCT concentration in 24 healthy and 5 septic horses to show the potential for clinical evaluation of equine PCT. Significantly different (P = 0.0006) mean equine PCT concentrations were found for the healthy control group and the sepsis group (47 and 8,450 ng mL(-1)).

  14. Entamoeba spp. diagnosis in patients with inflmmatory diarrhea by staining, copro-antigen ELISA and multiplex PCR methods

    Directory of Open Access Journals (Sweden)

    Zahra Gharibi

    2017-10-01

    Full Text Available Objective: To evaluate Entamoeba spp. diagnosis in patients with inflammatory diarrhea by staining, copro-antigen ELISA and multiplex PCR methods. Methods: In this descriptive cross-sectional survey, 200 stool samples were randomly collected during 2015–2016. The stool samples were evaluated microscopically for the presence of the parasite using direct and formalin-ether concentration and trichrome staining methods. Then, the stool samples were examined by copro-antigen ELISA (Biomerica Company and multiplex PCR methods. Results: Of 200 samples, 17, 29 and 23 cases were positive for Entamoeba species by the staining, copro-antigen ELISA and multiplex PCR methods, respectively. Of 23 positive samples in multiplex PCR test, 13 and 10 samples were positive for Entamoeba dispar (E. dispar and Entamoeba histolytica (E. histolytica, respectively. Conclusions: Our finding indicated a relatively high prevalence of Entamoeba species in patients with inflammatory diarrhea in Ahvaz city. Due to the complications of E. histolytica/ dispar infection, the health authorities of the city must pay more attention to control and prevent the transmission of E. histolytica/dispar to individuals.

  15. Setting up of a liquid chromatography-high resolution tandem mass spectrometry method for the detection of caseins in food. A comparison with ELISA method

    Directory of Open Access Journals (Sweden)

    Daniela Gastaldi

    2013-06-01

    Full Text Available Determination of caseins in food matrices is usually performed by using the competitiveenzyme- linked immunosorbent assay (ELISA technique. However such a technique suffers from a number of limitations. Among these, the applicability to a narrow concentration range, a non linear (logarithmic response, a non-negligible cross-reactivity and a high cost per kit. At the time of the completion of this study, in case of ELISA positive feedback, there was poor availability in the literature of finding reliable instrumental methods able to determine both qualitatively and quantitatively this class of substances. In the present study, a liquid chromatography-high resolution tandem mass spectrometry (HPLC-HRMS/MS instrumental method was developed with a high resolution mass spectrometer (Orbitrap. Real samples of sausages in which caseins were detected by ELISA technique were analysed. A casein-free sample of ham was used as a blank. The analytical characteristics of the instrumental method were compared with those of a commercial ELISA test, declared specific for α- and β-casein.

  16. Comparison of Laboratory-Developed and Commercial Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assays for Almond (Prunus dulcis) Detection and Quantification.

    Science.gov (United States)

    Liu, Changqi; Chhabra, Guneet S; Zhao, Jing; Zaffran, Valerie D; Gupta, Sahil; Roux, Kenneth H; Gradziel, Thomas M; Sathe, Shridhar K

    2017-10-01

    A commercially available monoclonal antibody (mAb)-based direct sandwich enzyme-linked immunosorbent assay (ELISA) kit (BioFront Technologies, Tallahassee, Fla., U.S.A.) was compared with an in-house developed mAb 4C10-based ELISA for almond detection. The assays were comparable in sensitivity (limit of detection almond, limit of quantification almond), specificity (no cross-reactivity with 156 tested foods at a concentration of 100000 ppm whole sample), and reproducibility (intra- and interassay variability almond seeds subjected to autoclaving, blanching, frying, microwaving, and dry roasting. The almond recovery ranges for spiked food matrices were 84.3% to 124.6% for 4C10 ELISA and 81.2% to 127.4% for MonoTrace ELISA. The almond recovery ranges for commercial and laboratory prepared foods with declared/known almond amount were 30.9% to 161.2% for 4C10 ELISA and 38.1% to 207.6% for MonoTrace ELISA. Neither assay registered any false-positive or negative results among the tested commercial and laboratory prepared samples. Ability to detect and quantify trace amounts of almonds is important for improving safety of almond sensitive consumers. Two monoclonal antibody-based ELISAs were compared for almond detection. The information is useful to food industry, regulatory agencies, scientific community, and almond consumers. © 2017 Institute of Food Technologists®.

  17. Characterization of ELISA Antibody-Antigen Interaction using Footprinting-Mass Spectrometry and Negative Staining Transmission Electron Microscopy

    Science.gov (United States)

    Lin, Margaret; Krawitz, Denise; Callahan, Matthew D.; Deperalta, Galahad; Wecksler, Aaron T.

    2018-05-01

    We describe epitope mapping data using multiple covalent labeling footprinting-mass spectrometry (MS) techniques coupled with negative stain transmission electron microscopy (TEM) data to analyze the antibody-antigen interactions in a sandwich enzyme-linked immunosorbant assay (ELISA). Our hydroxyl radical footprinting-MS data using fast photochemical oxidation of proteins (FPOP) indicates suppression of labeling across the antigen upon binding either of the monoclonal antibodies (mAbs) utilized in the ELISA. Combining these data with Western blot analysis enabled the identification of the putative epitopes that appeared to span regions containing N-linked glycans. An additional structural mapping technique, carboxyl group footprinting-mass spectrometry using glycine ethyl ester (GEE) labeling, was used to confirm the epitopes. Deglycosylation of the antigen resulted in loss of potency in the ELISA, supporting the FPOP and GEE labeling data by indicating N-linked glycans are necessary for antigen binding. Finally, mapping of the epitopes onto the antigen crystal structure revealed an approximate 90° relative spatial orientation, optimal for a noncompetitive binding ELISA. TEM data shows both linear and diamond antibody-antigen complexes with a similar binding orientation as predicted from the two footprinting-MS techniques. This study is the first of its kind to utilize multiple bottom-up footprinting-MS techniques and TEM visualization to characterize the monoclonal antibody-antigen binding interactions of critical reagents used in a quality control (QC) lot-release ELISA. [Figure not available: see fulltext.

  18. Characterization of ELISA Antibody-Antigen Interaction using Footprinting-Mass Spectrometry and Negative Staining Transmission Electron Microscopy

    Science.gov (United States)

    Lin, Margaret; Krawitz, Denise; Callahan, Matthew D.; Deperalta, Galahad; Wecksler, Aaron T.

    2018-03-01

    We describe epitope mapping data using multiple covalent labeling footprinting-mass spectrometry (MS) techniques coupled with negative stain transmission electron microscopy (TEM) data to analyze the antibody-antigen interactions in a sandwich enzyme-linked immunosorbant assay (ELISA). Our hydroxyl radical footprinting-MS data using fast photochemical oxidation of proteins (FPOP) indicates suppression of labeling across the antigen upon binding either of the monoclonal antibodies (mAbs) utilized in the ELISA. Combining these data with Western blot analysis enabled the identification of the putative epitopes that appeared to span regions containing N-linked glycans. An additional structural mapping technique, carboxyl group footprinting-mass spectrometry using glycine ethyl ester (GEE) labeling, was used to confirm the epitopes. Deglycosylation of the antigen resulted in loss of potency in the ELISA, supporting the FPOP and GEE labeling data by indicating N-linked glycans are necessary for antigen binding. Finally, mapping of the epitopes onto the antigen crystal structure revealed an approximate 90° relative spatial orientation, optimal for a noncompetitive binding ELISA. TEM data shows both linear and diamond antibody-antigen complexes with a similar binding orientation as predicted from the two footprinting-MS techniques. This study is the first of its kind to utilize multiple bottom-up footprinting-MS techniques and TEM visualization to characterize the monoclonal antibody-antigen binding interactions of critical reagents used in a quality control (QC) lot-release ELISA. [Figure not available: see fulltext.

  19. A Simple and Specific Noncompetitive ELISA Method for HT-2 Toxin Detection

    Directory of Open Access Journals (Sweden)

    Henri O. Arola

    2017-04-01

    Full Text Available We developed an HT-2 toxin-specific simple ELISA format with a positive read-out. The assay is based on an anti-immune complex (IC scFv antibody fragment, which is genetically fused with alkaline phosphatase (AP. The anti-IC antibody specifically recognizes the IC between a primary anti-HT-2 toxin Fab fragment and an HT-2 toxin molecule. In the IC ELISA format, the sample is added together with the scFv-AP antibody to the ELISA plate coated with the primary antibody. After 15 min of incubation and a washing step, the ELISA response is read. A competitive ELISA including only the primary antibody recognizes both HT-2 and T-2 toxins. The anti-IC antibody makes the assay specific for HT-2 toxin, and the IC ELISA is over 10 times more sensitive compared to the competitive assay. Three different naturally contaminated matrices: wheat, barley and oats, were used to evaluate the assay performance with real samples. The corresponding limits of detection were 0.3 ng/mL (13 µg/kg, 0.1 ng/mL (4 µg/kg and 0.3 ng/mL (16 µg/kg, respectively. The IC ELISA can be used for screening HT-2 toxin specifically and in relevant concentration ranges from all three tested grain matrices.

  20. Clinical evaluation of the Serum CrossLaps One Step ELISA, a new assay measuring the serum concentration of bone-derived degradation products of type I collagen C-telopeptides

    DEFF Research Database (Denmark)

    Christgau, S; Rosenquist, C; Alexandersen, P

    1998-01-01

    The Serum CrossLaps One Step ELISA is a sandwich assay using two monoclonal antibodies specific for a beta-aspartate form of the epitope EKAHDGGR derived from the carboxy-terminal telopeptide region of type I collagen alpha1-chain. Our objective was to assess the clinical value of the Serum Cross...

  1. Photocatalytic perfermance of sandwich-like BiVO_4 sheets by microwave assisted synthesis

    International Nuclear Information System (INIS)

    Liu, Suqin; Tang, Huiling; Zhou, Huan; Dai, Gaopeng; Wang, Wanqiang

    2017-01-01

    Graphical abstract: Sandwich-like BiVO_4 sheets were successfully synthesized via a facile microwave-assisted method. The as-prepared samples exhibit a high activity for the degradation of methyl orange under visible light irradiation. - Highlights: • Sandwich-like BiVO_4 sheets were synthesized by a facile microwave-assisted method. • The presence of PEG-10000 plays a critical role in the formation of BiVO_4 sheets. • Ostwald ripening is the primary driving force for the formation of sandwich-like BiVO_4. • The sandwich-like BiVO_4 sheets exhibit a high visible-light photocatalytic activity. - Abstract: Sandwich-like BiVO_4 sheets were successfully synthesized in an aqueous solution containing bismuth nitrate, ammonium metavanadate and polyethylene glycol with a molecular weight of 10,000 (PEG-10000) using a facile microwave-assisted method. The as-prepared samples were characterized by scanning electron microscopy, N_2 adsorption-desorption, X-ray diffraction, X-ray photoelectron spectroscopy (XPS), and UV–vis diffuse reflectance spectroscopy. The results show that the presence of PEG-10000 plays a critical role in the formation of BiVO_4 sheets, and Ostwald ripening is the primary driving force for the formation of sandwich-like structures. The sandwich-like BiVO_4 sheets exhibit a high activity for the degradation of methyl orange under visible light irradiation (λ ≥ 420 nm). The enhancement of photocatalytic activity of sandwich-like BiVO_4 sheets can be attributed to its large surface area over the irregular BiVO_4 particles.

  2. Robust and Air-Stable Sandwiched Organo-Lead Halide Perovskites for Photodetector Applications

    KAUST Repository

    Mohammed, Omar F.; Banavoth, Murali; Saidaminov, Makhsud I.; Abdelhady, Ahmed L.; Pan, Jun; Liu, Jiakai; Peng, Wei; Bakr, Osman

    2016-01-01

    We report the simplest possible method to date for fabricating robust, air-stable, sandwiched perovskite photodetectors. Our proposed sandwiched structure is devoid of electron or hole transporting layers and also the expensive electrodes

  3. Dynamic Response of Functionally Graded Carbon Nanotube Reinforced Sandwich Plate

    Science.gov (United States)

    Mehar, Kulmani; Panda, Subrata Kumar

    2018-03-01

    In this article, the dynamic response of the carbon nanotube-reinforced functionally graded sandwich composite plate has been studied numerically with the help of finite element method. The face sheets of the sandwich composite plate are made of carbon nanotube- reinforced composite for two different grading patterns whereas the core phase is taken as isotropic material. The final properties of the structure are calculated using the rule of mixture. The geometrical model of the sandwich plate is developed and discretized suitably with the help of available shell element in ANSYS library. Subsequently, the corresponding numerical dynamic responses computed via batch input technique (parametric design language code in ANSYS) of ANSYS including Newmark’s integration scheme. The stability of the sandwich structural numerical model is established through the proper convergence study. Further, the reliability of the sandwich model is checked by comparison study between present and available results from references. As a final point, some numerical problems have been solved to examine the effect of different design constraints (carbon nanotube distribution pattern, core to face thickness ratio, volume fractions of the nanotube, length to thickness ratio, aspect ratio and constraints at edges) on the time-responses of sandwich plate.

  4. Comparison of four functionalization methods of gold nanoparticles for enhancing the enzyme-linked immunosorbent assay (ELISA

    Directory of Open Access Journals (Sweden)

    Paula Ciaurriz

    2017-01-01

    Full Text Available The enzyme-linked immunosorbent assay (ELISA technique is based on the specific recognition ability of the molecular structure of an antigen (epitope by an antibody and is likely the most important diagnostic technique used today in bioscience. With this methodology, it is possible to diagnose illness, allergies, alimentary fraud, and even to detect small molecules such as toxins, pesticides, heavy metals, etc. For this reason, any procedures that improve the detection limit, sensitivity or reduce the analysis time could have an important impact in several fields. In this respect, many methods have been developed for improving the technique, ranging from fluorescence substrates to methods for increasing the number of enzyme molecules involved in the detection such as the biotin–streptavidin method. In this context, nanotechnology has offered a significant number of proposed solutions, mainly based on the functionalization of nanoparticles from gold to carbon which could be used as antibody carriers as well as reporter enzymes like peroxidase. However, few works have focused on the study of best practices for nanoparticle functionalization for ELISA enhancement. In this work, we use 20 nm gold nanoparticles (AuNPs as a vehicle for secondary antibodies and peroxidase (HRP. The design of experiments technique (DOE and four different methods for biomolecule loading were compared using a rabbit IgG/goat anti-rabbit IgG ELISA model (adsorption, directional, covalent and a combination thereof. As a result, AuNP probes prepared by direct adsorption were the most effective method. AuNPs probes were then used to detect gliadin, one of the main components of wheat gluten, the protein composite that causes celiac disease. With this optimized approach, our data showed a sensitivity increase of at least five times and a lower detection limit with respect to a standard ELISA of at least three times. Additionally, the assay time was remarkably decreased.

  5. Evaluation of a newly designed sandwich enzyme linked immunosorbent assay for the detection of hydatid antigen in serum, urine and cyst fluid for diagnosis of cystic echinococcosis.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2013-07-01

    Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE.

  6. Behavior of sandwich panels in a fire

    Science.gov (United States)

    Chelekova, Eugenia

    2018-03-01

    For the last decades there emerged a vast number of buildings and structures erected with the use of sandwich panels. The field of application for this construction material is manifold, especially in the construction of fire and explosion hazardous buildings. In advanced evacu-ation time calculation methods the coefficient of heat losses is defined with dire regard to fire load features, but without account to thermal and physical characteristics of building envelopes, or, to be exact, it is defined for brick and concrete walls with gross heat capacity. That is why the application of the heat loss coefficient expression obtained for buildings of sandwich panels is impossible because of different heat capacity of these panels from the heat capacities of brick and concrete building envelopes. The article conducts an analysis and calculation of the heal loss coefficient for buildings and structures of three layer sandwich panels as building envelopes.

  7. Comparison of the sensitivity of determining soyeabean allergens by ELISA method and SYBR green I

    Directory of Open Access Journals (Sweden)

    Jozef Golian

    2013-07-01

    Full Text Available Normal 0 false false false SK JA X-NONE The aim of this study was to compare the suitability of two methods for detecting defatted soybean powder; SYBR Green I Real-time PCR and enzyme-linked immunosorbent assay (ELISA. Analysis of 20 artificially contaminated samples prepared by simple dilution with wheat flour revealed that both techniques were able to detect defatted soybean powder, although there were significant differences between the two methods. Wheat flour contamination with defatted soybean powder was detected in samples 1-5, (0.012 %; 120 mg.kg-1, but not in samples with lower contamination with soybean powder saples 6-20 using SYBR Green I real-time PCR. Samples 1-10 could not be quantified by ELISA as the absorbance values were greater than the detection limit, and while samples 11-20 were measured, only the values of samples 16, 17 and 18 were within the guaranteed quantification range specified by the ELISA kit manufacturer. Defatted soybean powder contamination was detected in samples 19 and 20, but absorbance values were highly similar to those of the negative control sample.

  8. Highly graphitized laterally interconnected SWCNT network synthesis via a sandwich-grown method

    International Nuclear Information System (INIS)

    Teng, I-Ju; Chen, Kai-Ling; Wang, Li-Chun; Kuo, Cheng-Tzu; Hsu, Hui-Lin; Jian, Sheng-Rui; Chen, Jung-Hsuan; Wang, Wei-Hsiang

    2011-01-01

    We present a sandwich-grown method for growing laterally interconnected single-walled carbon nanotube (SWCNT) networks with a high degree of graphitization by microwave plasma chemical vapour deposition (MPCVD). An Al 2 O 3 -supported Fe catalyst precursor layer deposited on an oxidized Si substrate with an upper Si cover is first pretreated in pure hydrogen, and then exposed to a gas mixture of methane/hydrogen for growth process at a lower growth temperature and a faster rate. The effects of various parameters, such as catalyst film thickness, gas flow rate, working pressure, growth time and plasma power, on the morphologies and structural characteristics of the SWCNT networks are investigated, and therefore provide the essential conditions for direct growth of laterally interconnected SWCNT networks. Analytical results demonstrate that the SWCNT-based lateral architecture comprises a mixture of graphene-sheet-wrapped catalyst particles and laterally interconnected nanotubes, isolated or branched or assembled into bundles. The results also show that the formation of the laterally interconnected SWCNT networks is related to the sandwich-like stack approach and the addition of an Al 2 O 3 layer in the MPCVD process. The successful growth of lateral SWCNT networks provides new experimental information for simply and efficiently preparing lateral SWCNTs on unpatterned substrates, and opens a pathway to create network-structured nanotube-based devices.

  9. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    OpenAIRE

    Parma, Y. R.; Chacana, P. A.; Lucchesi, P. M. A.; Rogé, A.; Granobles Velandia, C. V.; Krüger, A.; Parma, A. E.; Fernández-Miyakawa, M. E.

    2012-01-01

    Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic-uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-St...

  10. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    OpenAIRE

    Yanil R Parma; Pablo A Chacana; Paula María Alejandra Lucchesi; Ariel eRoge; Claudia V Granobles Velandia; Alejandra eKrüger; Alejandra eKrüger; Alberto E. Parma; Mariano Enrique Fernandez Miyakawa

    2012-01-01

    Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-St...

  11. A simple sandwich ELISA (WELYSSA) for the detection of lyssavirus nucleocapsid in rabies suspected specimens using mouse monoclonal antibodies.

    Science.gov (United States)

    Xu, Gelin; Weber, Patrick; Hu, Qiaoling; Xue, Honggang; Audry, Laurent; Li, Chengping; Wu, Jie; Bourhy, Herve

    2007-10-01

    Monoclonal antibody (MAb)-based capture enzyme-linked immunosorbent assays (ELISA) were developed for the diagnosis of rabies-suspect specimens. A combination of four mouse monoclonal antibodies directed against the rabies virus nucleocapsid was selected and used for the detection. The test was optimized and standardized so that maximum concordance could be maintained with the standard procedures of rabies diagnosis recommended by the WHO expert committee. Using prototype viruses from the different genotypes of lyssavirus and from various geographic origins and phylogenetic lineages, this paper presents a reliable, rapid and transferable diagnostic method, named WELYSSA that readily permits the detection of lyssaviruses belonging to the 7 genotypes of lyssavirus circulating in Europe, Africa, Asia and Oceania. The threshold of detection of lyssavirus nucleocapsids is low (0.8 ng/ml). With a panel of 1030 specimens received for rabies diagnostic testing, this test was found to be highly specific (0.999) and sensitive (0.970) when compared to other recommended rabies diagnostic methods.

  12. Determination of aflatoxins in nuts of Tabriz confectionaries by ELISA and HPLC methods

    Directory of Open Access Journals (Sweden)

    Siahi Shadbad Mohammad Reza

    2012-06-01

    Full Text Available Purpose: Aflatoxins (AFs are a group of mycotoxins and secondary metabolites of various species of Aspergillus. There are various forms of aflatoxins including B1, B2, G1, G2, M1 and M2 types. Aflatoxins cause important health problems and have high potential effect on liver cancer. Therefore, numerous investigations have been conducted during last three decades. The aim of this work is to determine the contamination levels of nuts used by the confectionaries in Tabriz. Methods: A total of 142 samples including 35 almond , 26 walnut, 4 seeds of apricot, 6 sunflower seeds kernel, 6 sesame seed, 6 peanuts , 32 pistachio,13 hazelnuts and 14 cashews samples were collected from Tabriz confectionaries. The ELISA method was employed for the screening of total aflatoxins. Results: In 13 cases (28.1% of pistachios, 5.1% of walnuts and 7.1% of cashews contamination rate of higher than 15 ppb were observed. The HPLC method was applied for the confirmation of ELISA results. Aflatoxin B1 was the highest detected AFs. Conclusion: The overall results of the tested samples indicated that the rate of contamination of pistachios is higher than the other tested samples.

  13. Energy Dissipation in Sandwich Structures During Axial Compression

    DEFF Research Database (Denmark)

    Urban, Jesper

    2002-01-01

    The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full-scale structu......The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full...

  14. Validation of the FAO/IAEA/PANAFTOSA ELISA kit for determination of antibodies against foot-and-mouth disease virus

    International Nuclear Information System (INIS)

    Maradei, E.; Pedemonte, A.

    1998-01-01

    A Liquid phase blocking sandwich ELISA (LPBE) for the detection of foot-and-mouth disease (FMD) antibodies, serotypes O, A and C was validated using sera from bovines free of antibodies and vaccinated bovines. This technique proved to be sensitive and specific for the study of these antibodies. This kit has been prepared by the Pan American Foot-and-Mouth Disease Center (PAHO/WHO) in collaboration with the Animal Production and Health Section of the Joint FAO/IAEA Division, Vienna, Austria and the Institute for Animal Health in Pirbright, United Kingdom. (author)

  15. Photocatalytic perfermance of sandwich-like BiVO{sub 4} sheets by microwave assisted synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Suqin, E-mail: liusuqin888@126.com [Department of Chemical engineering and Food Science, Hubei University of arts and science, Xiangyang 441053 (China); Hubei Key Laboratory of Low Dimensional Optoelectronic Materials and Devices, Xiangyang 441053 (China); Tang, Huiling; Zhou, Huan [Department of Chemical engineering and Food Science, Hubei University of arts and science, Xiangyang 441053 (China); Dai, Gaopeng, E-mail: dgp2000@126.com [Department of Chemical engineering and Food Science, Hubei University of arts and science, Xiangyang 441053 (China); Wang, Wanqiang [Department of Chemical engineering and Food Science, Hubei University of arts and science, Xiangyang 441053 (China)

    2017-01-01

    Graphical abstract: Sandwich-like BiVO{sub 4} sheets were successfully synthesized via a facile microwave-assisted method. The as-prepared samples exhibit a high activity for the degradation of methyl orange under visible light irradiation. - Highlights: • Sandwich-like BiVO{sub 4} sheets were synthesized by a facile microwave-assisted method. • The presence of PEG-10000 plays a critical role in the formation of BiVO{sub 4} sheets. • Ostwald ripening is the primary driving force for the formation of sandwich-like BiVO{sub 4}. • The sandwich-like BiVO{sub 4} sheets exhibit a high visible-light photocatalytic activity. - Abstract: Sandwich-like BiVO{sub 4} sheets were successfully synthesized in an aqueous solution containing bismuth nitrate, ammonium metavanadate and polyethylene glycol with a molecular weight of 10,000 (PEG-10000) using a facile microwave-assisted method. The as-prepared samples were characterized by scanning electron microscopy, N{sub 2} adsorption-desorption, X-ray diffraction, X-ray photoelectron spectroscopy (XPS), and UV–vis diffuse reflectance spectroscopy. The results show that the presence of PEG-10000 plays a critical role in the formation of BiVO{sub 4} sheets, and Ostwald ripening is the primary driving force for the formation of sandwich-like structures. The sandwich-like BiVO{sub 4} sheets exhibit a high activity for the degradation of methyl orange under visible light irradiation (λ ≥ 420 nm). The enhancement of photocatalytic activity of sandwich-like BiVO{sub 4} sheets can be attributed to its large surface area over the irregular BiVO{sub 4} particles.

  16. Detection and determination of Melamine in infant formula by ELISA method

    Directory of Open Access Journals (Sweden)

    A Shakerian

    2012-05-01

    Full Text Available Thirty-six samples of infant formula with different production dates and various brands were purchased from Isfahan city during 2012. The samples were assayed for the presence and quantity of melamine by ELISA screening method. According to the results, in any infant formula melamine contamination was observed above the detection limit of the kit (10 µg/L. Therefore, it was concluded that the infant formula at Isfahan retail is not considered a health hazard from the melamine contamination point of view.

  17. Analytical/Empirical Study on Indentation Behavior of Sandwich Plate with Foam Core and Composite Face Sheets

    Directory of Open Access Journals (Sweden)

    Soheil Dariushi

    2017-07-01

    Full Text Available Sandwich structures are widely used in aerospace, automobile, high speed train and civil applications. Sandwich structures consist of two thin and stiff skins and a thick and light weight core. In this study, the obligatory mandate of a sandwich plate contact constitutes a flexible foam core and composite skins with a hemispherical rigid punch has been studied by an analytical/empirical method. In sandwich structures, calculation of force distribution under the punch nose is complicated, because the core is flexible and the difference between the modulus of elasticity of skin and core is large. In the present study, an exponential correlation between the contact force and indentation is proposed. The coefficient and numerical exponent were calculated using the experimental indentation results. A model based on a high-order sandwich panel theory was used to study the bending behavior of sandwich plate under hemispherical punch load. In the first method, the force distribution under the punch nose was calculated by the proposed method and multiplied to deformation of related point in the loading area to calculate the potential energy of the external loads. In the second method, the punch load was modeled as a point force and multiplied to deformation of maximum indented point. The results obtained from the two methods were compared with the experimental results. Indentation and bending tests were carried out on sandwich plates with glass/epoxy skins and a styrene/acrylonitrile foam core. In the bending test, a simply support condition was set and in the indentation test the sandwich specimens were put on a rigid support. Indeed, in this position the punch movement was equal the indentation. The comparison between the analytical and experimental results showed that the proposed method significantly improved the accuracy of analysis.

  18. New "sandwich" structures conformed from three dimensional

    Directory of Open Access Journals (Sweden)

    Alba, Juan J.

    1996-03-01

    Full Text Available Poor interlaminar properties as well as poor-skin-to-core adhesion properties are very often the common existing problems we find when designing with "sandwich" structures. A new type of 3D-fabric "sandwich" structure is being developed in order to avoid these problems. Although the manufacturing process is very simple, a very complex "sandwich" structure is obtained as a result of the complexity of the 3D-fabric used. This 3D-fabric is a 3D woven glass fabric produced on velvet weaving machines with glass yarns. It is an integrally woven "sandwich" laminate for all kinds of composite products. The strength of the vertical fibers makes, that also after impregnation with a resin matrix, the "sandwich" structure is maintained. The result is a laminate with high strength and stiffness and low weight. On each side of this "sandwich" laminate additional reinforcement materials can be laminated and a synthetic foam can be injected in the hollow structure. This will allow to establish the mechanical properties of a finished product.

    Las pobres propiedades, tanto interlaminares como de adhesión entre piel y núcleo, constituyen uno de los grandes problemas cuando se diseñan estructuras utilizando paneles tipo "sandwich". Un nuevo tipo de panel "sandwich", configurado a partir de tejidos tridimensionales, está siendo desarrollado en la actualidad con el objetivo de eliminar esos problemas. Aunque el proceso de fabricación es muy simple, el panel "sandwich" obtenido es de estructura compleja, como resultado de la complejidad del tejido tridimensional utilizado. Este tejido tridimensional (3D es un tejido de fibra de vidrio producido en máquinas de tejer especializadas. La resistencia de las fibras verticales hace que, después de la impregnación con una resina, se mantenga la configuración tipo "sandwich". El resultado es un laminado de alta resistencia, gran rigidez y bajo peso. Sobre cada uno de los lados del panel "sandwich" se pueden

  19. Monoclonal antibody-based serological methods for detection of Cucumber green mottle mosaic virus

    Directory of Open Access Journals (Sweden)

    Qian Yajuan

    2011-05-01

    Full Text Available Abstract Background Cucumber green mottle mosaic virus (CGMMV, a member of the genus Tobamovirus, can be transmitted by seeds and infects many cucurbit species, causing serious yield losses in cucumber and watermelon plants. In this paper, five serological methods including antigen-coated plate enzyme-linked immunosorbent assay (ACP-ELISA, triple antibody sandwich enzyme-linked immunosorbent assay (TAS-ELISA, Dot-immunobinding assay (DBIA, direct tissue blot immunoassay (DTBIA and immunocapture reverse transcriptase polymerase chain reaction (IC-RT-PCR were described for detection and diagnosis of CGMMV. Results Using the purified CGMMV particles as immunogens, six murine monoclonal antibodies (MAbs were produced. Five serological methods were established using the MAb 4H1 and detection sensitivity was compared using purified preparations and infected-plant tissue extracts. The detection sensitivity of ACP-ELISA was 0.16 ng of purified CGMMV, whereas TAS-ELISA was more sensitive than ACP-ELISA with a minimum detection of 0.04 ng of purified CGMMV. The sensitivities of TAS-ELISA and DBIA were similar for detecting CGMMV in infected-plant tissue extracts, and were four times higher than ACP-ELISA. The IC-RT-PCR was the most sensitive method, which could detect as little as 0.1 pg of purified virus. The detection sensitivity of IC-RT-PCR for CGMMV-infected plant tissues was about 400 times higher than that of TAS-ELISA and DBIA. Conclusions The established ACP-ELISA, TAS-ELISA, DBIA and DTBIA are suitable for routine CGMMV detection of large-scale samples in the field survey, while IC-RT-PCR is more sensitive and suitable for acquiring information about the viral genome.

  20. Sound transmission loss of composite sandwich panels

    Science.gov (United States)

    Zhou, Ran

    Light composite sandwich panels are increasingly used in automobiles, ships and aircraft, because of the advantages they offer of high strength-to-weight ratios. However, the acoustical properties of these light and stiff structures can be less desirable than those of equivalent metal panels. These undesirable properties can lead to high interior noise levels. A number of researchers have studied the acoustical properties of honeycomb and foam sandwich panels. Not much work, however, has been carried out on foam-filled honeycomb sandwich panels. In this dissertation, governing equations for the forced vibration of asymmetric sandwich panels are developed. An analytical expression for modal densities of symmetric sandwich panels is derived from a sixth-order governing equation. A boundary element analysis model for the sound transmission loss of symmetric sandwich panels is proposed. Measurements of the modal density, total loss factor, radiation loss factor, and sound transmission loss of foam-filled honeycomb sandwich panels with different configurations and thicknesses are presented. Comparisons between the predicted sound transmission loss values obtained from wave impedance analysis, statistical energy analysis, boundary element analysis, and experimental values are presented. The wave impedance analysis model provides accurate predictions of sound transmission loss for the thin foam-filled honeycomb sandwich panels at frequencies above their first resonance frequencies. The predictions from the statistical energy analysis model are in better agreement with the experimental transmission loss values of the sandwich panels when the measured radiation loss factor values near coincidence are used instead of the theoretical values for single-layer panels. The proposed boundary element analysis model provides more accurate predictions of sound transmission loss for the thick foam-filled honeycomb sandwich panels than either the wave impedance analysis model or the

  1. Development of ELISA for the detection of transgenic vegetative insecticidal protein in GM crops/produce.

    Science.gov (United States)

    Kumar, R

    2012-01-11

    In the process of the development of insect-resistant genetically modified (GM) crops and also to evaluate the consistency in the expression of toxin under field conditions, immunological assays are commonly being used. An immunoassay was developed to support the labelling of vegetative insecticidal protein (Vip3A)-based GM produce. The developed ELISA for the measurement of Vip3A is a triple antibody sandwich procedure utilising a polyclonal capture antibody (mouse anti-Vip3A) and a polyclonal detection antibody (rabbit anti-Vip3A) followed by use of a third HRP-conjugated anti-species antibody (goat anti-rabbit IgG). The limit of detection limit of the ELISA assay was 16 ng ml(-1) with a linear quantification range from approximately 31 to 500 ng ml(-1) of Vip3A protein. Furthermore, the assay was in-house validated with GM brinjal samples. The assay was specific, sensitive and reproducible, which can be helpful to detect and track down the spread of unapproved and intentionally/unintentionally released GM produce harbouring Vip protein.

  2. Robust and Air-Stable Sandwiched Organo-Lead Halide Perovskites for Photodetector Applications

    KAUST Repository

    Mohammed, Omar F.

    2016-02-25

    We report the simplest possible method to date for fabricating robust, air-stable, sandwiched perovskite photodetectors. Our proposed sandwiched structure is devoid of electron or hole transporting layers and also the expensive electrodes. These simpler architectures may have application in the perovskite-only class of solar cells scaling up towards commercialization.

  3. Synthesis-based approach toward direct sandwich immunoassay for ciguatoxin CTX3C.

    Science.gov (United States)

    Oguri, Hiroki; Hirama, Masahiro; Tsumuraya, Takeshi; Fujii, Ikuo; Maruyama, Megumi; Uehara, Hisatoshi; Nagumo, Yoko

    2003-06-25

    Ciguatoxins are the major causative toxins of ciguatera seafood poisoning. Limited availability of ciguatoxins has hampered the development of a reliable and specific immunoassay for detecting these toxins in contaminated fish. Monoclonal antibodies (mAbs) specific against both ends of ciguatoxin CTX3C were prepared by immunization of mice with protein conjugates of rationally designed synthetic haptens, 3 and 4, in place of the natural toxin. Haptenic groups that possess a surface area larger than 400 A(2) were required to produce mAbs that can bind strongly to CTX3C itself. A direct sandwich enzyme-linked immunosorbent assay (ELISA) using these mAbs was established to detect CTX3C at the ppb level with no cross-reactivity against other related marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, or maitotoxin.

  4. Acoustic wave spread in superconducting-normal-superconducting sandwich

    International Nuclear Information System (INIS)

    Urushadze, G.I.

    2004-01-01

    The acoustic wave spread, perpendicular to the boundaries between superconducting and normal metals in superconducting-normal-superconducting (SNS) sandwich has been considered. The alternate current flow sound induced by the Green function method has been found and the coefficient of the acoustic wave transmission through the junction γ=(S 1 -S 2 )/S 1 , (where S 1 and S 2 are average energy flows formed on the first and second boundaries) as a function of the phase difference between superconductors has been investigated. It is shown that while the SNS sandwich is almost transparent for acoustic waves (γ 0 /τ), n=0,1,2, ... (where τ 0 /τ is the ratio of the broadening of the quasiparticle energy levels in impurity normal metal as a result of scattering of the carriers by impurities 1/τ to the spacing between energy levels 1/τ 0 ), γ=2, (S 2 =-S 1 ), which corresponds to the full reflection of the acoustic wave from SNS sandwich. This result is valid for the limit of a pure normal metal but in the main impurity case there are two amplification and reflection regions for acoustic waves. The result obtained shows promise for the SNS sandwich as an ideal mirror for acoustic wave reflection

  5. Detection of toxoplasma-specific immunoglobulin G in human sera: performance comparison of in house Dot-ELISA with ECLIA and ELISA.

    Science.gov (United States)

    Teimouri, Aref; Modarressi, Mohammad Hossein; Shojaee, Saeedeh; Mohebali, Mehdi; Zouei, Nima; Rezaian, Mostafa; Keshavarz, Hossein

    2018-05-08

    In the current study, performance of electrochemiluminescence immunoassay (ECLIA) in detection of anti-toxoplasma IgG in human sera was compared with that of enzyme-linked immunosorbent assay (ELISA). Furthermore, performance of an in house Dot-ELISA in detection of anti-toxoplasma IgG was compared with that of ECLIA and ELISA. In total, 219 human sera were tested to detect anti-toxoplasma IgG using Dynex DS2® and Roche Cobas® e411 Automated Analyzers. Discordant results rechecked using immunofluorescence assay (IFA). Then, sera were used in an in house Dot-ELISA to assess toxoplasma-specific IgG. Of the 219 samples, two samples were found undetermined using ECLIA but reactive using ELISA. Using IFA, the two sera were reported unreactive. Furthermore, two samples were found reactive using ECLIA and unreactive using ELISA. These samples were reported reactive using IFA. The overall agreement for the two former methods was 98% (rZ0.98.1; P house Dot-ELISA included sensitivity of 79.5, specificity of 78.2, and accuracy of 78.9%, compared to ECLIA and ELISA. Positive and negative predictive values included 82.9 and 74.2%, respectively. A 100% sensitivity was found in in house Dot-ELISA for highly reactive sera in ECLIA and ELISA. ECLIA is appropriate for the first-line serological screening tests and can replace ELISA due to high speed, sensitivity, and specificity, particularly in large laboratories. Dot-ELISA is a rapid, sensitive, specific, cost-effective, user-friendly, and field-portable technique and hence can be used for screening toxoplasmosis, especially in rural fields or less equipped laboratories.

  6. Expression, purification of metallothionein genes from freshwater crab (Sinopotamon yangtsekiense) and development of an anti-metallothionein ELISA

    Science.gov (United States)

    Zhang, Hao; Zhou, Hui

    2017-01-01

    Using the phoA-fusion technology, the recombinant metallothionein (MT) from freshwater crab (Sinopotamon yangtsekiense) has been successfully produced in Escherichia coli. MT purified from the bacterial suspension showed one polypeptide with a molecular weight of 7 kDa by tricine-sodium dodecyl sulfate-polyacrylamide gel electrophoresis (Tricine-SDS-PAGE). Western-blotting confirmed the polypeptides had a specific reactivity with mouse polyclonal MT anti-serum. Based on the purified MT and MT anti-serum, the reaction parameters for an enzyme-linked immunosorbent assay (ELISA) were developed. The direct coating ELISA showed a higher linear relationship compared to antibody sandwich coating ELISA. The optimal dilution rates of purified MT anti-serum and coating period were shown to be 1:160,000 and 12 hours at 4°C. At 37°C, the appropriate reaction duration of the first antibody and the second antibody were 2 hours and 1 hour, respectively. According to these optimal parameters, the standard linear equation, y = 0.0032x + 0.1769 (R2 = 0.9779, x, y representing MT concentration and OD450 value), was established for the determination of MT concentration with a valid range of 3.9–500 ng/ml. In verification experiments, the mean coefficients of variation of the intra-assay and inter-assay were 3.260% and 3.736%, respectively. According to the result of MT recovery, ELISA with an approaching 100% MT recovery was more reliable and sensitive than the Cd saturation assay. In conclusion, the newly developed ELISA of this study was precise, stable and repeatable, and could be used as a biomarker tool to monitor pollution by heavy metals. PMID:28350826

  7. (ELISA) kit for diagnosis copro-antigens of Giardia lamblia

    African Journals Online (AJOL)

    STORAGESEVER

    2010-08-02

    Aug 2, 2010 ... methods based on antigen scanning of parasites such as enzyme linked immunosorbent assay (ELISA), ... samples. To design this method, a pure antibody against parasite as well as an antibody conjugated to a ..... school children in Santiago, Chile by capture ELISA for the detection of fecal Giardia ...

  8. DETERMINATION OF HISTAMINE IN FISH USING ELISA TECHNIQUE

    NARCIS (Netherlands)

    KRUGER, C; SEWING, U; STENGEL, G; KEMA, [No Value; WESTERMANN, J; MANZ, B

    1995-01-01

    The analysis of histamine in fish and fish products via competitive ELISA is described. The advantages of this method are easy sample preparation and handling, screening capabilities, and low costs. Automation enables the performance of the assay with higher series of samples. The Histamine-ELISA is

  9. High temperature structural sandwich panels

    Science.gov (United States)

    Papakonstantinou, Christos G.

    High strength composites are being used for making lightweight structural panels that are being employed in aerospace, naval and automotive structures. Recently, there is renewed interest in use of these panels. The major problem of most commercial available sandwich panels is the fire resistance. A recently developed inorganic matrix is investigated for use in cases where fire and high temperature resistance are necessary. The focus of this dissertation is the development of a fireproof composite structural system. Sandwich panels made with polysialate matrices have an excellent potential for use in applications where exposure to high temperatures or fire is a concern. Commercial available sandwich panels will soften and lose nearly all of their compressive strength temperatures lower than 400°C. This dissertation consists of the state of the art, the experimental investigation and the analytical modeling. The state of the art covers the performance of existing high temperature composites, sandwich panels and reinforced concrete beams strengthened with Fiber Reinforced Polymers (FRP). The experimental part consists of four major components: (i) Development of a fireproof syntactic foam with maximum specific strength, (ii) Development of a lightweight syntactic foam based on polystyrene spheres, (iii) Development of the composite system for the skins. The variables are the skin thickness, modulus of elasticity of skin and high temperature resistance, and (iv) Experimental evaluation of the flexural behavior of sandwich panels. Analytical modeling consists of a model for the flexural behavior of lightweight sandwich panels, and a model for deflection calculations of reinforced concrete beams strengthened with FRP subjected to fatigue loading. The experimental and analytical results show that sandwich panels made with polysialate matrices and ceramic spheres do not lose their load bearing capability during severe fire exposure, where temperatures reach several

  10. Rapid enzyme-linked immunosorbent assay (ELISA) for Aspergillus fumigatus antibodies.

    OpenAIRE

    Richardson, M D; Stubbins, J M; Warnock, D W

    1982-01-01

    A rapid enzyme-linked immunosorbent assay (ELISA) where component incubation periods were shortened to one hour, was compared with agar gel double diffusion (AGDD) and a standard ELISA procedure for detecting antibodies to Aspergillus fumigatus in 28 asthmatic patients with suspected allergic aspergillosis. Using two A fumigatus antigens the rapid ELISA compared well with AGDD and the standard ELISA method. Eleven sera that reacted with both antigens in AGDD were all positive against antigen ...

  11. Antibody-nanoparticle conjugates to enhance the sensitivity of ELISA-based detection methods.

    Directory of Open Access Journals (Sweden)

    Margaret M Billingsley

    Full Text Available Accurate antigen detection is imperative for clinicians to diagnose disease, assess treatment success, and predict patient prognosis. The most common technique used for the detection of disease-associated biomarkers is the enzyme linked immunosorbent assay (ELISA. In an ELISA, primary antibodies are incubated with biological samples containing the biomarker of interest. Then, detectible secondary antibodies conjugated with horseradish peroxidase (HRP bind the primary antibodies. Upon addition of a color-changing substrate, the samples provide a colorimetric signal that directly correlates to the targeted biomarker concentration. While ELISAs are effective for analyzing samples with high biomarker content, they lack the sensitivity required to analyze samples with low antigen levels. We hypothesized that the sensitivity of ELISAs could be enhanced by replacing freely delivered primary antibodies with antibody-nanoparticle conjugates that provide excess binding sites for detectible secondary antibodies, ultimately leading to increased signal. Here, we investigated the use of nanoshells (NS decorated with antibodies specific to epidermal growth factor receptor (EGFR as a model system (EGFR-NS. We incubated one healthy and two breast cancer cell lines, each expressing different levels of EGFR, with EGFR-NS, untargeted NS, or unconjugated EGFR antibodies, as well as detectable secondary antibodies. We found that EGFR-NS consistently increased signal intensity relative to unconjugated EGFR antibodies, with a substantial 13-fold enhancement from cells expressing high levels of EGFR. Additionally, 40x more unconjugated antibodies were required to detect EGFR compared to those conjugated to NS. Our results demonstrate that antibody-nanoparticle conjugates lower the detection limit of traditional ELISAs and support further investigation of this strategy with other antibodies and nanoparticles. Owing to their enhanced sensitivity, we anticipate that

  12. Applications of thin-film sandwich crystallization platforms

    Energy Technology Data Exchange (ETDEWEB)

    Axford, Danny, E-mail: danny.axford@diamond.ac.uk; Aller, Pierre; Sanchez-Weatherby, Juan; Sandy, James [Diamond Light Source, Harwell Oxford, Didcot OX11 0DE (United Kingdom)

    2016-03-24

    Crystallization via sandwiches of thin polymer films is presented and discussed. Examples are shown of protein crystallization in, and data collection from, solutions sandwiched between thin polymer films using vapour-diffusion and batch methods. The crystallization platform is optimal for both visualization and in situ data collection, with the need for traditional harvesting being eliminated. In wells constructed from the thinnest plastic and with a minimum of aqueous liquid, flash-cooling to 100 K is possible without significant ice formation and without any degradation in crystal quality. The approach is simple; it utilizes low-cost consumables but yields high-quality data with minimal sample intervention and, with the very low levels of background X-ray scatter that are observed, is optimal for microcrystals.

  13. Analysis of fenbendazole residues in bovine milk by ELISA.

    Science.gov (United States)

    Brandon, David L; Bates, Anne H; Binder, Ronald G; Montague, William C; Whitehand, Linda C; Barker, Steven A

    2002-10-09

    Fenbendazole residues in bovine milk were analyzed by ELISAs using two monoclonal antibodies. One monoclonal antibody (MAb 587) bound the major benzimidazole anthelmintic drugs, including fenbendazole, oxfendazole, and fenbendazole sulfone. The other (MAb 591) was more specific for fenbendazole, with 13% cross-reactivity with the sulfone and no significant binding to the sulfoxide metabolite. The limit of detection of the ELISA method in the milk matrix was 7 ppb for MAb 587 and 3 ppb for MAb 591. Fenbendazole was administered in feed, drench, and paste form to three groups of dairy cattle. Milk was collected immediately before dosing and then every 12 h for 5 days. The ELISA indicated that residue levels varied widely among individual cows in each group. Fenbendazole levels peaked at approximately 12-24 h and declined rapidly thereafter. Metabolites were detected at much higher levels than the parent compound, peaked at approximately 24-36 h, and declined gradually. Residue levels were undetectable by 72 h. The ELISA data correlated well with the total residues determined by chromatographic analysis, but the use of the two separate ELISAs did not afford an advantage over ELISA with the single, broadly reactive MAb 587. The ELISA method could be used to flag high-residue samples in on-site monitoring of fenbendazole in milk and is a potential tool for studying drug pharmacokinetics.

  14. ELISA-BASE: an integrated bioinformatics tool for analyzing and tracking ELISA microarray data

    OpenAIRE

    White, Amanda M.; Collett, James R.; Seurynck-Servoss, Shannon L.; Daly, Don S.; Zangar, Richard C.

    2009-01-01

    Summary:ELISA-BASE is an open source database for capturing, organizing and analyzing enzyme-linked immunosorbent assay (ELISA) microarray data. ELISA-BASE is an extension of the BioArray Software Environment (BASE) database system.

  15. Quantification of alpha-tubulin isotypes by sandwich ELISA with signal amplification through biotinyl-tyramide or immuno-PCR

    Czech Academy of Sciences Publication Activity Database

    Dráberová, Eduarda; Stegurová, Lucie; Sulimenko, Vadym; Hájková, Zuzana; Dráber, Petr; Dráber, Pavel

    2013-01-01

    Roč. 395, 1-2 (2013), s. 63-70 ISSN 0022-1759 R&D Projects: GA AV ČR KAN200520701; GA ČR GAP302/12/1673; GA ČR GPP302/11/P709; GA ČR GAP302/10/1759; GA ČR GA301/09/1826; GA MŠk(CZ) LD13015; GA MŠk LD12073 Institutional support: RVO:68378050 Keywords : alpha-tubulin isotypes * biotinyl-tyramide * ELISA * immuno-PCR * mast cells Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.005, year: 2013

  16. Comparison of DNA probe, PCR amplification, ELISA and culture methods for the rapid detection of Salmonella in poultry

    International Nuclear Information System (INIS)

    Qasem, J.A.; Al-Mouqati, S.; Rajkumar, G.

    2005-01-01

    The identification of Salmonella spp. from poultry meat was studied by comparing bacterial detection using the Gene-Trak colorimetric hybridization method, a PCR amplification kit and an Enzyme Linked Immunosorbent Assay (ELISA), and these methods were compared with the conventional methodology proposed by the United States Food and Drug Administration (US FDA) for detection of Salmonella in food samples. Forty positive and negative samples were studied. The three methods yielded similar results with levels of Salmonella greater than 10 CFU per sample, even when the samples were highly contaminated with competing bacteria. In contrast, 20 CFU of seed inoculum per sample was the lowest level of Salmonella detectable with all three methods and the standard culture method. The detection limits of the PCR and ELISA assays were 5 CFU/g after enrichment at 37 deg. C for 6 and 9 hours, respectively. Compared with conventional bacteriology, all three methods here demonstrated high sensitivity and specificity for Salmonella. (author)

  17. Creep of sandwich beams with metallic foam cores

    International Nuclear Information System (INIS)

    Kesler, O.; Crews, L.K.; Gibson, L.J.

    2003-01-01

    The steady state creep deflection rates of sandwich beams with metallic foam cores were measured and compared with analytical and numerical predictions of the creep behavior. The deflection rate depends on the geometry of the sandwich beam, the creep behavior of the foam core and the loading conditions (stress state, temperature). Although there was a considerable scatter in the creep data (both of the foams and of the sandwich beams made using them), the data for the sandwich beams were fairly well described by the analysis

  18. Creep of sandwich beams with metallic foam cores

    Energy Technology Data Exchange (ETDEWEB)

    Kesler, O.; Crews, L.K.; Gibson, L.J

    2003-01-20

    The steady state creep deflection rates of sandwich beams with metallic foam cores were measured and compared with analytical and numerical predictions of the creep behavior. The deflection rate depends on the geometry of the sandwich beam, the creep behavior of the foam core and the loading conditions (stress state, temperature). Although there was a considerable scatter in the creep data (both of the foams and of the sandwich beams made using them), the data for the sandwich beams were fairly well described by the analysis.

  19. Effect of microencapsulated phase change material in sandwich panels

    Energy Technology Data Exchange (ETDEWEB)

    Castellon, Cecilia; Medrano, Marc; Roca, Joan; Cabeza, Luisa F. [GREA Innovacio Concurrent, Edifici CREA, Universitat de Lleida, Pere de Cabrera s/n, 25001 Lleida (Spain); Navarro, Maria E.; Fernandez, Ana I. [Departamento de Ciencias de los Materiales e Ingenieria Metalurgica, Universitat de Barcelona, Marti i Franques 1, 08028 Barcelona (Spain); Lazaro, Ana; Zalba, Belen [Instituto de Investigacion en Ingenieria de Aragon, I3A, Grupo de Ingenieria Termica y Sistemas Energeticos (GITSE), Dpto. Ingenieria Mecanica, Area de Maquinas y Motores Termicos, Universidad de Zaragoza, Campus Politecnico Rio Ebro, Edificio ' ' Agustin de Betancourt,' ' Maria de Luna s/n, 50018 Zaragoza (Spain)

    2010-10-15

    Sandwich panels are a good option as building materials, as they offer excellent characteristics in a modular system. The goal of this study was to demonstrate the feasibility of using the microencapsulated PCM (Micronal BASF) in sandwich panels to increase their thermal inertia and to reduce the energy demand of the final buildings. In this paper, to manufacture the sandwich panel with microencapsulated PCM three different methods were tested. In case 1, the PCM was added mixing the microencapsulated PCM with one of the components of the polyurethane. In the other two cases, the PCM was added either a step before (case 2) or a step after (case 3) to the addition of the polyurethane to the metal sheets. The results show that in case 1 the effect of PCM was overlapped by a possible increase in thermal conductivity, but an increase of thermal inertia was found in case 3. In case 2, different results were obtained due to the poor distribution of the PCM. Some samples showed the effect of the PCM (higher thermal inertia), and other samples results were similar to the conventional sandwich panel. In both cases (2 and 3), it is required to industrialize the process to improve the results. (author)

  20. Transferability of antibody pairs from ELISA to fiber optic surface plasmon resonance for infliximab detection

    Science.gov (United States)

    Van Stappen, Thomas; Lu, Jiadi; Bloemen, Maarten; Geukens, Nick; Spasic, Dragana; Delport, Filip; Verbiest, Thierry; Lammertyn, Jeroen; Gils, Ann

    2015-03-01

    Tumor necrosis factor (TNF)-alpha is a pleiotropic cytokine up-regulated in inflammatory bowel disease, rheumatoid arthritis and psoriasis. The introduction of anti-TNF drugs such as infliximab has revolutionized the treatment of these diseases. Recently, therapeutic drug monitoring (TDM) of infliximab has been introduced in clinical decision making to increase cost-efficiency. Nowadays, TDM is performed using radio-immunoassays, homogeneous mobility shift assays or ELISA. Unfortunately, these assays do not allow for in situ treatment optimization, because of the required sample transportation to centralized laboratories and the subsequent assay execution time. In this perspective, we evaluated the potential of fiber optic-surface plasmon resonance (FO-SPR). To achieve this goal, a panel of 55 monoclonal anti-infliximab antibodies (MA-IFX) was developed and characterized in-house, leading to the identification of nine different clusters. Based on this high diversity, 22 antibody pairs were selected and tested for their reactivity towards IFX, using one MA-IFX as capture and one MA-IFX for detection, in a sandwich type ELISA and FO-SPR. This study showed that the reactivity towards IFX of each antibody pair in ELISA is highly similar to its reactivity on FO-SPR, indicating that antibody pairs are easily transferable between both platforms. Given the fact that FO-SPR shows the potential for miniaturization and fast assay time, it can be considered a highly promising platform for on-site infliximab monitoring.

  1. Tailoring Sandwich Face/Core Interfaces for Improved Damage Tolerance

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Berggreen, Christian; Carlsson, Leif A.

    2010-01-01

    Various modifications of the face/core interface in foam core sandwich specimens are examined in a series of two papers. This paper constitutes part I and describes the finite element analysis of a sandwich test specimen, i.e. a DCB specimen loaded by uneven bending moments (DCB-UBM). Using...... this test almost any mode-mixity between pure mode I and mode II can be obtained. A cohesive zone model of the mixed mode fracture process involving large-scale bridging is developed. Results from the analysis are used in Part II, which describes methods and results of a series of experiments....

  2. High performance sandwich structured Si thin film anodes with LiPON coating

    Science.gov (United States)

    Luo, Xinyi; Lang, Jialiang; Lv, Shasha; Li, Zhengcao

    2018-04-01

    The sandwich structured silicon thin film anodes with lithium phosphorus oxynitride (LiPON) coating are synthesized via the radio frequency magnetron sputtering method, whereas the thicknesses of both layers are in the nanometer range, i.e. between 50 and 200 nm. In this sandwich structure, the separator simultaneously functions as a flexible substrate, while the LiPON layer is regarded as a protective layer. This sandwich structure combines the advantages of flexible substrate, which can help silicon release the compressive stress, and the LiPON coating, which can provide a stable artificial solidelectrolyte interphase (SEI) film on the electrode. As a result, the silicon anodes are protected well, and the cells exhibit high reversible capacity, excellent cycling stability and good rate capability. All the results demonstrate that this sandwich structure can be a promising option for high performance Si thin film lithium ion batteries.

  3. Comparison of IgM Capture Enzyme- Linked Immunosorbent Assay (ELISA) using Inhouse method and commercially available MRL kit for serological confirmation of dengue infection

    International Nuclear Information System (INIS)

    Hapugoda, D.M.; De Silva R, Nilanthi; Abeywickreme, W.; Gunasena, Sunethra; Prithimala, L.D.; Jayawardene, S.L.G.J.; Kumari, Thamara

    2003-01-01

    Laboratory diagnosis of dengue infection is important for the management of the patients. In this study igM capture ELISA using an inhouse method and commercially available kit (MRL diagnostics,USA) was compared to detect diagnostic capability of Inhouse IgM ELISA for provision of diagnostic facilities to the public at an affordable cost. Eighty acute and convalescent serum samples were collected from serologically confirmed dengue patients. Serological confirmation of patients were performed by Haemagglutination Inhibition (HI) assay, gold standard assay for dengue on paired serum samples. All collected acute and convalescent sera were tested by IgM ELISA using the inhouse method and MRL kit. Antigen and conjugate for the inhouse IgM method were prepared in the laboratory. A cocktail of four dengue antigens containing 25 Antigen ELISA units of each type was prepared and used as the assay antigen. Conjugate was prepared using a serum sample with high dengue Anti flavi IgG antibody titre conjugated with Horseradish peroxidase. A prospective study of both IgM ELISA assays were performed using 113 acute sera collected from dengue suspected cases. Overall results showed that 46% and 52% acute sera collected from dengue confirmed patients were positive by inhouse ELISA assay and MRL kits respectively. In the prospective study done using acute sera collected from dengue suspected patients showed that 44% and 52% were positive by inhouse ELISA assay and MRL kits. There was no significant difference in positivity between these two assays. (P=0.18). Inhouse IgM ELISA can be used for provision of laboratory diagnosis of dengue virus infection more than 5 days. The assay is 10 times less costly than using MRL kits as assay antigen and conjugate can be prepared easily in the laboratory

  4. Advanced Mechanical Testing of Sandwich Materials

    DEFF Research Database (Denmark)

    Hayman, Brian; Berggreen, Christian; Jenstrup, Claus

    2008-01-01

    An advanced digital optical system has been used to measure surface strains on sandwich face and core specimens tested in a project concerned with improved criteria for designing sandwich X-joints. The face sheet specimens were of glass reinforced polyester and were tested in tension. The core sp...

  5. A Rapid ELISA Method for 17, 20b-dihydroxy-4-pregenen-3-one (17,20bP Hormone Using Acetylcholinesterase Enzyme as Tracer

    Directory of Open Access Journals (Sweden)

    M Ebrahimi

    2004-06-01

    Full Text Available Background: During the past 15 years Enzyme Linked ImmunoSorbent Assay (ELISA has been described as an alternative to radioimmunoassay for steroid detection. In addition to gonads, sperm itself is capable of producing reduced progesterone metabolites. In this study we introduced a method to extend the applicability of previous measures by describing a general preparation procedure for the enzyme label which is applicable to any steroid hormone. Methods: A simple and rapid Enzyme Linked Immunosorbant Assay (ELISA is described and validated for 17,20β- dihydroxy-4-pregnen-3-one (17,20βP. A general procedure for preparation of the acetylcholinesterase labelled steroid is described which is applicable to any steroid. Results: Use of acetylcholinesterase tracer increased the sensitivity of assay so that reliable measurements of each steroid could be achieved with only 10 µl of plasma. ELISA was applied to measure of 17,20βP steroid production by sperm of trout which has sufficient amount of potent and active 20βHSD enzyme to convert 17α-hydroxy-4-pregnen-3-one (17αP substrate to 17,20βP product. The results showed that a clear shift in 17,20βP production was found with increase in substrate concentration in all in vitro incubations. Conclusion: ELISA method presented in this study has greater sensitivity and accuracy compared to previously described method that uses radiolabelled substances. Keywords: Immunoassay, ELISA, Steroids, Hormone, Assay

  6. Development of monoclonal antibodies to pre-haptoglobin 2 and their use in an enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Flanagan, J J; Arjomandi, A; Delanoy, M L; Du Paty, E; Galea, P; Laune, D; Rieunier, F; Walker, R P; Binder, S R

    2014-04-01

    Haptoglobins (HPs) are alpha 2-globulin proteins that bind free hemoglobin in plasma to prevent oxidative damage. HPs are produced as preproteins that are proteolytically cleaved in the ER into alpha and beta chains prior to forming mature, functional tetramers. Two alleles exist in humans (HP1 and HP2), therefore three genotypes are present in the population, i.e., HP1-1, HP2-1, and HP2-2. A biochemical role for nascent haptoglobin 2 (pre-haptoglobin 2 or pre-HP2) as the only known modulator of intestinal permeability has been established. In addition, elevated levels of serum pre-HP2 have been detected in multiple conditions including celiac disease and type I diabetes, which are believed to result in part through dysregulation of the intestinal barrier. In this study, we report the development of a monoclonal antibody that is specific for pre-HP2 with a binding affinity in the nanomolar range. Additional antibodies with specificities for preHP but not mature haptoglobin were also characterized. A sandwich enzyme-linked immunosorbent assay (ELISA) was established and validated. The ELISA showed high specificity for pre-HP2 even in the presence of excess pre-HP1 or mature haptoglobins, and has excellent linearity and inter- and intra-assay reproducibility with a working range from 3.1ng/mL to 200ng/mL. Testing of sera from 76 healthy patients revealed a non-Gaussian distribution of pre-HP2 levels with a mean concentration of 221.2ng/mL (95% CI: 106.5-335.9ng/mL) and a median value of 23.9ng/mL. Compared to current approaches, this ELISA offers a validated, monoclonal-based method with high sensitivity and specificity for measuring pre-HP2 in human serum. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Low Velocity Impact Properties of Aluminum Foam Sandwich Structural Composite

    Directory of Open Access Journals (Sweden)

    ZHAO Jin-hua

    2018-01-01

    Full Text Available Sandwich structural composites were prepared by aluminum foam as core materials with basalt fiber(BF and ultra-high molecular weight polyethylene(UHMWPE fiber composite as faceplate. The effect of factors of different fiber type faceplates, fabric layer design and the thickness of the corematerials on the impact properties and damage mode of aluminum foam sandwich structure was studied. The impact properties were also analyzed to compare with aluminum honeycomb sandwich structure. The results show that BF/aluminum foam sandwich structural composites has bigger impact damage load than UHMWPE/aluminum foam sandwich structure, but less impact displacement and energy absorption. The inter-layer hybrid fabric design of BF and UHMWPE has higher impact load and energy absorption than the overlay hybrid fabric design faceplate sandwich structure. With the increase of the thickness of aluminum foam,the impact load of the sandwich structure decreases, but the energy absorption increases. Aluminum foam sandwich structure has higher impact load than the aluminum honeycomb sandwich structure, but smaller damage energy absorption; the damage mode of aluminum foam core material is mainly the fracture at the impact area, while aluminum honeycomb core has obvious overall compression failure.

  8. Novel sandwich structure adsorptive membranes for removal of 4-nitrotoluene from water

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Yuexin [College of Chemistry, Beijing Normal University, Beijing 100875 (China); School of Pharmacy, North China University of Science and Technology, Tangshan 063000 (China); Jia, Zhiqian, E-mail: zhqjia@bnu.edu.cn [College of Chemistry, Beijing Normal University, Beijing 100875 (China)

    2016-11-05

    Highlights: • Novel sandwich PES-SPES/PS-PDVB/PTFE adsorptive membranes were prepared. • The removal efficiency for 4-nitrotoluene is greater than 95% after five recycles. • The membrane showed higher adsorption capacity than that of mixed matrix membrane. - Abstract: Novel sandwich PES-SPES/PS-PDVB/PTFE adsorptive membranes were prepared by a filtration/immersion precipitation method and employed for the removal of 4-nitrotoluene from water. The static adsorption thermodynamics, kinetics, dynamic adsorption/desorption and membrane reusability were investigated. The results showed that the Freundlich model describes the adsorption isotherm satisfactorily. With increased PS-PDVB content, the maximum static adsorption capacity, partition coefficient, apparent adsorption rate constant, and dynamic adsorption capacity all significantly increased. The sandwich membranes showed much higher removal efficiency and adsorption capacity than those of mixed matrix membranes. With respect to dynamics adsorption/desorption, the sandwich membranes exhibited excellent reusability, with a removal efficiency greater than 95% even after five recycles.

  9. Production of monoclonal antibodies for sandwich immunoassay detection of Pacific ciguatoxins.

    Science.gov (United States)

    Tsumuraya, Takeshi; Fujii, Ikuo; Hirama, Masahiro

    2010-10-01

    Ciguatoxins are the major causative toxins of ciguatera seafood poisoning. Limited availability of ciguatoxins has hampered the development of a reliable and specific immunoassay for detecting these toxins in contaminated fish. Monoclonal antibodies (mAbs) specific against both ends of Pacific ciguatoxins CTX3C and 51-hydroxyCTX3C were prepared by immunization of mice with the protein conjugates of rationally designed synthetic haptens in place of the natural toxin. Haptenic groups that possess a surface area larger than 400 A(2) were required to produce mAbs that can bind strongly to CTX3C or 51-hydroxyCTX3C. A direct sandwich enzyme-linked immunosorbent assay (ELISA) using these mAbs was established to detect CTX3C and 51-hydroxyCTX3C at the ppb level with no cross-reactivity against the other marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, or maitotoxin. Copyright 2009 Elsevier Ltd. All rights reserved.

  10. Technological features of installation of transformable low-rise buildings from sandwich panels

    Directory of Open Access Journals (Sweden)

    Pleshivtsev Aleksandr Aleksandrovich

    2018-04-01

    Full Text Available Subject of research: organizational and technological solutions are considered in the construction of transformable low-rise residential buildings using sandwich panels. Aims: rational choice of organizational and technological solutions for the rhythmic construction of the underground and above-ground part of the transformable low-rise buildings in order to reduce labor costs and construction time. Materials and methods: methods of computer modeling of the technological processes are used to determine the duration of the construction of the low-rise buildings. Results: rational methods for erecting a complex of transformable low-rise buildings are defined, parameters of technological processes are established, an analysis of technological operations is provided for the construction of transformable low-rise residential buildings using sandwich panels. Conclusions: now organizational and technological solutions for the construction of transformable low-rise residential buildings with the use of sandwich panels reduce labour costs, increase the construction pace and as well as the using of improved technological processes in the construction of such buildings leads to a reduction in construction time.

  11. Micro-vibration response of a stochastically excited sandwich beam with a magnetorheological elastomer core and mass

    International Nuclear Information System (INIS)

    Ying, Z G; Ni, Y Q

    2009-01-01

    Magnetorheological (MR) elastomers are used to construct a smart sandwich beam for micro-vibration control. The micro-vibration response of a clamped–free sandwich beam with an MR elastomer core and a supplemental mass under stochastic support micro-motion excitation is studied. The dynamic behavior of MR elastomer as a smart viscoelastic material is described by a complex modulus which is controllable by external magnetic field. The sixth-order partial differential equation of motion of the sandwich beam is derived from the dynamic equilibrium, constitutive and geometric relations. A frequency-domain solution method for the stochastic micro-vibration response of the sandwich beam is developed by using the frequency-response function, power spectral density function and spatial eigensolution. The root-mean-square velocity response in terms of the one-third octave frequency band is calculated, and then the response reduction capacity through optimizing the complex modulus of the core is analyzed. Numerical results illustrate the influences of the MR elastomer core parameters on the root-mean-square velocity response and the high response reduction capacity of the sandwich beam. The developed analysis method is applicable to sandwich beams with arbitrary cores described by complex shear moduli under arbitrary stochastic excitations described by power spectral density functions

  12. Lab-on-chip system combining a microfluidic-ELISA with an array of amorphous silicon photosensors for the detection of celiac disease epitopes

    Directory of Open Access Journals (Sweden)

    Francesca Costantini

    2015-12-01

    Full Text Available This work presents a lab-on-chip system, which combines a glass-polydimethilsiloxane microfluidic network and an array of amorphous silicon photosensors for the diagnosis and follow-up of Celiac disease. The microfluidic chip implements an on-chip enzyme-linked immunosorbent assay (ELISA, relying on a sandwich immunoassay between antibodies against gliadin peptides (GPs and a secondary antibody marked with horseradish peroxidase (Ig-HRP. This enzyme catalyzes a chemiluminescent reaction, whose light intensity is detected by the amorphous silicon photosensors and transduced into an electrical signal that can be processed to recognize the presence of antibodies against GPs in the serum of people affected by Celiac syndrome.The correct operation of the developed lab-on-chip has been demonstrated using rabbit serum in the microfluidic ELISA. In particular, optimizing the dilution factors of both sera and Ig-HRP samples in the flowing solutions, the specific and non-specific antibodies against GPs can be successfully distinguished, showing the suitability of the presented device to effectively screen celiac disease epitopes. Keywords: Lab-on-chip, Celiac disease, Microfluidics, On-chip detection, ELISA, Amorphous silicon photosensors

  13. Thermal conductivity of newspaper sandwiched aerated lightweight concrete panel

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Soon-Ching; Low, Kaw-Sai [Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Jalan Genting Kelang, Setapak, 53300 Kuala Lumpur, Wilayah Persekutuan (Malaysia)

    2010-12-15

    Investigation on the thermal conductivity of newspaper sandwiched aerated lightweight concrete (ALC) panels is the main purpose of this study. Various densities of ALC panels ranging from 1700, 1400 and 1100 kg/m{sup 3} with three different aerial intensities of newspaper sandwiched were produced. Investigation was limited to the effect of aerial intensity of newspaper sandwiched and the effect of density of ALC on thermal conductivity. It is found that the thermal conductivity of newspaper sandwiched ALC panels reduced remarkably compared to control ALC panels. The reduction was recorded at 18.0%, 21.8% and 20.7% correspond to densities of 1700, 1400 and 1100 kg/m{sup 3} with just a mere 0.05 g/cm{sup 2} aerial intensity of newspaper sandwiched. Newspaper sandwiched has a significant impact on the performance of thermal conductivity of ALC panels based on regression analysis. (author)

  14. Predicting safe sandwich production

    DEFF Research Database (Denmark)

    Birk, Tina; Duan, Zhi; Møller, Cleide Oliveira de Almeida

    2014-01-01

    Time and temperature control is crucial to avoid growth of pathogens during production and serving of cold ready-to-eat meals. The Danish guidelines state that chilled foods, such as sandwiches, should not be outside the cold chain for more than 3 hours including the time for preparation...... and serving. However, Danish sandwich producing companies find it challenging to comply with this and have expressed a need for more flexibility. The Danish guidelines do allow for a prolongation of the acceptable time outside the cold chain, if the safety of the specific production can be documented...

  15. Numerical simulation of the hole-flanging process for steel-polymer sandwich sheets

    Science.gov (United States)

    Griesel, Dominic; Keller, Marco C.; Groche, Peter

    2018-05-01

    In light of increasing demand for lightweight structures, hybrid materials are frequently used in load-optimized parts. Sandwich structures like metal-polymer sandwich sheets provide equal bending stiffness as their monolithic counterparts at a drastically reduced weight. In addition, sandwich sheets have noise-damping properties, thus they are well-suited for a large variety of parts, e.g. façade and car body panels, but also load-carrying components. However, due to the creep tendency and low heat resistance of the polymer cores, conventional joining technologies are only applicable to a limited degree. Through hole-flanging it is possible to create branches in sandwich sheets to be used as reinforced joints. While it is state of the art for monolithic materials, hole-flanging of sandwich sheets has not been investigated yet. In order to simulate this process for different material combinations and tool geometries, an axisymmetric model has been developed in the FE software Abaqus/CAE. In the present paper, various modeling strategies for steel-polymer sandwich sheets are examined, including volume elements, shell elements and combinations thereof. Different methods for joining the distinct layers in the FE model are discussed. By comparison with CT scans and optical 3D measurements of experimentally produced hole-flanges, the feasibility of the presented models is evaluated. Although a good agreement of the numerical and experimental results has been achieved, it becomes clear that the classical forming limit diagram (FLD) does not adequately predict failure of the steel skins.

  16. Development of Aircraft Sandwich Parts

    Directory of Open Access Journals (Sweden)

    J. Křena

    2000-01-01

    Full Text Available The presented paper shows the design and development process of sandwich parts. A spoiler plate and a main landing gear door are developed. Sandwich parts are made of C/E composite facings and a foam core. FE models have been used for optimization of structures. Emphasis has been placed on deformations of parts under a few load cases. Experimental tests have been used for a verification of structure parts loaded by concentrated forces.

  17. ITO-TiN-ITO Sandwiches for Near-Infrared Plasmonic Materials.

    Science.gov (United States)

    Chen, Chaonan; Wang, Zhewei; Wu, Ke; Chong, Haining; Xu, Zemin; Ye, Hui

    2018-05-02

    Indium tin oxide (ITO)-based sandwich structures with the insertion of ultrathin (ITO layers show TiN-thickness-dependent properties, which lead to moderate and tunable effective permittivities for the sandwiches. The surface plasmon polaritons (SPP) of the ITO-TiN-ITO sandwich at the telecommunication window (1480-1570 nm) are activated by prism coupling using Kretschmann configuration. Compared with pure ITO films or sandwiches with metal insertion, the reflectivity dip for sandwiches with TiN is relatively deeper and wider, indicating the enhanced coupling ability in plasmonic materials for telecommunications. The SPP spatial profile, penetration depth, and degree of confinement, as well as the quality factors, demonstrate the applicability of such sandwiches for NIR plasmonic materials in various devices.

  18. Improved methods for urinary atrazine mercapturate analysis-Assessment of an enzyme-linked immunosorbent assay (ELISA) and a novel liquid chromatography-mass spectrometry (LC-MS) method utilizing online solid phase extraction (SPE)

    International Nuclear Information System (INIS)

    Koivunen, Marja E.; Dettmer, Katja; Vermeulen, Roel; Bakke, Berit; Gee, Shirley J.; Hammock, Bruce D.

    2006-01-01

    Elimination of interfering substances in urine by solid phase extraction (SPE) prior to analysis resulted in 10-fold improvement in the sensitivity of atrazine mercapturate (AM) enzyme-linked immunosorbent assay (ELISA) compared to previous reports. Of the two tested SPE systems, Oasis[reg] HLB and MCX, the mixed-mode MCX gave good recoveries (82%) of AM in spiked samples measured by ELISA, whereas the reverse-phase HLB phase was not compatible with the immunochemical method. At relatively high concentrations of urinary AM (>20 ng mL -1 ), sample dilution was effective enough for the elimination of interfering substances. The new liquid chromatography-mass spectrometry (LC-MS) method developed for AM utilizes online-SPE with Oasis[reg] HLB, column switching and a stable-isotope internal standard. The limit of quantification (0.05 ng mL -1 ) indicates improved sensitivity compared with most previously published LC-MS methods for AM. Validation of all three methods, LC-MS, ELISA + SPE and ELISA + dilution with spiked urine samples showed good correlation between the known and measured concentrations with R 2 values of 0.996, 0.957 and 0.961, respectively. When a set (n = 70 plus 12 blind duplicates) of urine samples from farmers exposed to atrazine was analyzed, there was a good agreement (R 2 = 0.917) between the log normalized data obtained by ELISA + SPE and LC-MS. High correlation among the data obtained by the two tested methods and the LC-MS method by the Center of Disease Control and Prevention (CDC), together with low variability among the blind duplicates, suggests that both methods reported here would be suitable for the analysis of urinary AM as a biomarker for human exposure of atrazine

  19. Intrant ELISA: A Novel Approach to Fabrication of Electrospun Fiber Mat-Assisted Biosensor Platforms and Their Integration within Standard Analytical Well Plates

    Directory of Open Access Journals (Sweden)

    Samira Hosseini

    2016-11-01

    Full Text Available A combination of far-field electrospinning (FFES and free-radical polymerization has been used to fabricate coated electrospun polymer fiber mats as a new type of biosensor platform. Poly (3-hydroxybutyrate-co-3-hydroxyvalerate (PHBV electrospun fibers were dip-coated with different compositions of poly methyl methacrylate-co-methacrylic acid (poly(MMA-co-MAA. This synergistic approach utilizes large specific surface area of PHBV fibers and co-polymer coatings that feature an optimum concentration of surface carboxyl (–COOH groups. The platform surface morphology, porosity and tunable hydrophobicity enhance biomolecular interactions via plurality of molecular forces. These customized fiber mats have been integrated into a newly designed 96-well plate called an “intrant enzyme-linked immunosorbent assay” or i-ELISA. I-ELISA allows colorimetric sandwich assay to be carried out without any modifications or additional steps in ELISA methodology. By introducing the fiber mats in fabrication of i-ELISA via extensions on the lid, we address some of the limitations of the previous designs while demonstrating an enhanced signal intensity up to 12 times higher than that of conventional assays. With improved sensitivity, specificity and accuracy in the detection of dengue virus, i-ELISA has proven to be a reliable platform for biomolecular recognition. The proposed fiber mat-assisted well plate in this study holds great potential as a universal approach for integration of different types of fiber mats with pre-designed specific properties in order to enhance the detection sensitivity of the assay.

  20. Experimental formability analysis of bondal sandwich sheet

    Science.gov (United States)

    Kami, Abdolvahed; Banabic, Dorel

    2018-05-01

    Metal/polymer/metal sandwich sheets have recently attracted the interests of industries like automotive industry. These sandwich sheets have superior properties over single-layer metallic sheets including good sound and vibration damping and light weight. However, the formability of these sandwich sheets should be enhanced which requires more research. In this paper, the formability of Bondal sheet (DC06/viscoelastic polymer/DC06 sandwich sheet) was studied through different types of experiments. The mechanical properties of Bondal were determined by uniaxial tensile tests. Hemispherical punch stretching and hydraulic bulge tests were carried out to determine the forming limit diagram (FLD) of Bondal. Furthermore, cylindrical and square cup drawing tests were performed in dry and oil lubricated conditions. These tests were conducted at different blank holding forces (BHFs). An interesting observation about Bondal sheet deep drawing was obtaining of higher drawing depths at dry condition in comparison with oil-lubricated condition.

  1. Vibro-acoustics of lightweight sandwich structures

    CERN Document Server

    Lu, Tianjian

    2014-01-01

    Vibro-Acoustics of Lightweight Sandwich Structures introduces the study of the coupled vibration and acoustic behavior of lightweight sandwich structures in response to harmonic force and sound pressure. This book focuses on the theoretical modeling and experimental investigation of lightweight sandwich structures in order to provide a predictive framework for vibro-acoustic characteristics of typical engineering structures. Furthermore, by developing solution tools, it concentrates on the influence of key systematic parameters leading to effective guidance for optimal structure design toward lightweight, high-stiffness and superior sound insulation capability. This book is intended for researchers, scientists, engineers and graduate students in mechanical engineering especially in structural mechanics, mechanics and acoustics. Fengxian Xin and Tianjian Lu both work at the School of Aerospace, Xi’an Jiaotong University.

  2. Pistachio (Pistacia vera L.) Detection and Quantification Using a Murine Monoclonal Antibody-Based Direct Sandwich Enzyme-Linked Immunosorbent Assay.

    Science.gov (United States)

    Liu, Changqi; Chhabra, Guneet S; Sathe, Shridhar K

    2015-10-21

    A commercially available direct sandwich enzyme-linked immunosorbent assay (ELISA) (BioFront Technologies, Tallahassee, FL, USA) using murine anti-pistachio monoclonal antibodies (mAbs) as capture and detection antibodies was evaluated. The assay was sensitive (limit of detection = 0.09 ± 0.02 ppm full fat pistachio, linear detection range = 0.5-36 ppm, 50% maximum signal concentration = 7.9 ± 0.7 ppm), reproducible (intra- and inter-assay variability pistachio seeds subjected to autoclaving (121 °C, 15 psi, 15, 30 min), blanching (100 °C, 5, 10 min), frying (191 °C, 1 min), microwaving (500, 1000 W, 3 min), and dry roasting (140 °C, 30 min; 168 °C, 12 min). No cross-reactivity was observed in 156 food matrices, each tested at 100,000 ppm, suggesting the ELISA to be pistachio specific. The pistachio recovery ranges for spiked (10 ppm) and incurred (10-50000 ppm) food matrices were 93.1-125.6% and 35.7-112.2%, respectively. The assay did not register any false-positive or -negative results among the tested commercial and laboratory prepared samples.

  3. Non-linear Behavior of Curved Sandwich Panels

    DEFF Research Database (Denmark)

    Berggreen, Carl Christian; Jolma, P.; Karjalainen, J. P.

    2003-01-01

    In this paper the non-linear behavior of curved sandwich panels is investigated both numerically and experimentally. Focus is on various aspects of finite element modeling and calculation procedures. A simply supported, singly curved, CFRP/PVC sandwich panel is analyzed under uniform pressure loa...

  4. Fracture Characterization of Sandwich Face/Core Interfaces

    DEFF Research Database (Denmark)

    Manca, Marcello

    of load transfer between the faces and the core layer is lost, the debonds are considered as primary damage initiators. Under fatigue loading the debonds may evolve into cracks that cause a reduction in structural performance and consequent failure. At present most structural design is based on “life-time...... of sandwich structures is defects that are introduced in the manufacturing process. It is inevitable that areas of the face sheets will not fully adhere to the core resulting in defects known as “debonds”. Debonds can also be induced in-service due to e.g. localised impact loading or overloading. As the means...... such result it is important to devise new experimental and analytical techniques to establish the multi-mode fracture characteristics of sandwich plate structures and accordingly develop methods to inhibit defect propagation. This thesis deals with characterization of fracture between face and core...

  5. Fracture Characterization of PVC Foam Core Sandwich Specimen Using the DCB-UBM Test Method

    DEFF Research Database (Denmark)

    Saseendran, Vishnu; Berggreen, Christian; Carlsson, Leif A.

    coupled with experimental validation is paramount to determine the fracture resistance of the face/core interface. In this paper, the test-rig exploiting the double cantilever beam with uneven bending moments (DCB-UBM) concept is used to determine the fracture toughness of PVC foam core sandwich......Face/core debond failure in sandwich composites is a critical failure mode. Lack of cohesion between face and core will lead to loss of structural integrity. The estimation of interface fracture toughness especially at the face/core interface is extremely challenging, provided the dissimilarity...... composites. The DCB-UBM test enables fracture testing over a large range of mode-mixities as expressed by a phase angle (ψ) which is a measure of the amount of shear loading at the crack tip. A desired phase angle may be achieved by changing the moment-ratio (MR = Md/Ms)....

  6. Development and evaluation of aerogel-filled BMI sandwich panels for thermal barrier applications

    Directory of Open Access Journals (Sweden)

    A. Dineshkumar

    2016-07-01

    Full Text Available This study details a fabrication methodology envisaged to manufacture Glass/BMI honeycomb core aerogel-filled sandwich panels. Silica aerogel granules are used as core fillers to provide thermal insulation properties with little weight increase. Experimental heat transfer studies are conducted on these panels to study the temperature distribution between their two surfaces. Numerical studies are also carried out to validate the results. Despite exhibiting good thermal shielding capabilities, the Glass/BMI sandwich panels are found to oxidise at 180 ºC if exposed directly to heat. In order to increase the temperature bearing capacity and the operating temperature range for these panels, a way of coating them from outside with high temperature spray paint was tried. With a silicone-based coating, the temperature sustainability of these sandwich panels is found to increase to 350 ºC. This proved the effectiveness of the formed manufacturing process, selected high temperature coating, the coating method as well as the envisaged sandwich panel concept.

  7. FaceSheet Push-off Tests to Determine Composite Sandwich Toughness at Cryogenic Temperatures

    Science.gov (United States)

    Gates, Thomas S.; Herring, Helen M.

    2001-01-01

    A new novel test method, associated analysis, and experimental procedures are developed to investigate the toughness of the facesheet-to-core interface of a sandwich material at cryogenic temperatures. The test method is designed to simulate the failure mode associated with facesheet debonding from high levels of gas pressure in the sandwich core. The effects of specimen orientation are considered, and the results of toughness measurements are presented. Comparisons are made between room and liquid nitrogen (-196 C) test temperatures. It was determined that the test method is insensitive to specimen facesheet orientation and strain energy release rate increases with a decrease in the test temperature.

  8. Nonglobal proof of the thin--sandwich conjecture

    International Nuclear Information System (INIS)

    Pereira, C.M.

    1981-01-01

    A gravitational thin--sandwich conjecture was first proposed by Wheeler and coworkers during the period 1962--4. The present paper contains a proof of the nonglobal form of this gravitational thin--sandwich conjecture. The proof (a) applies for arbitrary choices of the spatial metric and its time derivative; and (b) demonstrates the existence on a spacelike three-surface of solutions which satisfy conditions of continuity known to be sufficient to obtain existence and uniqueness of solutions to Einstein's equations off the three-surface and existence and uniqueness of geodesics. Riquier's existence theorem plays an important role in the proof. The relationship of the present results to previous work is discussed. Some global questions associated with the thin--sandwich conjecture are clarified. Some aspects of the relationship of the thin--sandwich conjecture to the problem of the quantization of the gravitational field are noted. Both the vacuum case and the case of a nonviscous fluid are included. The discussion allows for an arbitrary equation of state p = p

  9. Development of ELISA kit for rat albumin

    International Nuclear Information System (INIS)

    Yuan Zhigang; Han Shiquan; Liu Yibing; Xu Wenge; Jia Juanjuan

    2009-01-01

    The Anti-rat albumin serum was prepared by immunized the sheep with rat albumin. A ELISA method was established for rat albumin. The measurement range of the assay was 1-50 mg/L, sensitivity of the assay was 0.42 mg/L, recovery rate was 85.0%-106.0%. Intra-and inter-assay variation coefficients were <8.9% and <12.8% respectively. The correlation coefficients between measured and expected values were 0.999 after serial dilution of the urine samples with high concentrations of rat albumin. A good correlation was observed between the ELISA and RIA methods, and the kit for rat albumin might provide a convenience in exploitation of renal drugs and experimental injury of the kidney. (authors)

  10. Sandwich immunoassay for alpha-fetoprotein in human sera using gold nanoparticle and magnetic bead labels along with resonance Rayleigh scattering readout

    International Nuclear Information System (INIS)

    Lu, Yao; Huang, Xiangyi; Ren, Jicun

    2013-01-01

    We describe a sensitive sandwich immunoassay for alpha-fetoprotein (AFP). It is making use of gold nanoparticles (GNPs) and magnetic beads (MBs) as labels, and of resonance Rayleigh scattering for detection. Two antibodies were labeled with GNPs and MBs, respectively, and MB-antigen-GNP complexes were formed in the presence of antigens. The MB labels also serve as solid phase carriers that can be used to magnetically separate the immuno complex. The GNP labels are used as optical probes, and Rayleigh scattering was used to determine the concentration of free GNPs-antibody after separation of the MB-antigen-GNP complexes. The concentration of AFP is related to the intensity of light scattered by free GNPs in the 13.6 pM to 436 pM concentration range, and the limit of detection is 13.6 pM. The method was applied to the determination of AFP in sera of cancer patients, and the results agree well with those obtained by conventional ELISA. (author)

  11. Characterization of sandwich panels for indentation and impact

    International Nuclear Information System (INIS)

    Shazly, M; Salem, S; Bahei-El-Din, Y

    2013-01-01

    The integrity of sandwich structures which are susceptible to impact may deteriorate significantly due to collapse of the core material and delamination of the face sheets. The integration of a thin polyurethane interlayer between the composite face sheet and foam core is known to protect the core material and substantially improve the resistance to impact. The objective of the present work is to characterize the response of sandwich panels, as well as that of the constituents to impact. In particular, the response of polyurethane and foam samples under a range of quasi-static and dynamic loading rates is determined experimentally. Furthermore, the response of sandwich panels to quasi-static indentation and low velocity impact is examined to quantify the extent of damage and how it is affected by the integration of polyurethane interlayers in their construction. This information is useful in the modelling of high velocity impact of sandwich panels; an effort which is currently underway. The results illustrate the benefit of using polyurethane interlayers within the construction of sandwich panels in enhancing their performance under quasi-static indentation and impact loads

  12. Development and application of radioimmunoassays and enzyme immunoassays in microbiological and immunological diagnosis. 2. Comparative studies for the detection of toxoplasma antibodies with ELISA, RIA and other serological methods

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, W A; Struy, H; Holzwarth, F [Medizinische Akademie, Magdeburg (German Democratic Republic)

    1982-06-01

    Comparative studies of indirect immunofluorescence test (IT), complement binding reaction (CBR), enzyme- and radioimmunoassay (ELISA, RIA) for the detection of toxoplasma antibodies in sera of 513 patients are reported. The precision dependent on time, showed coefficients of variation from 3% to 12% (IFT 3%, CBR 10%, ELISA 12%, RIA 7%). The correlation of IFT and ELISA as well as RIA was relatively unfavourable (coefficient of correlation IFT/ELISA r = 0.52, IFT/RIA r = 0.54, RIA/ELISA r = 0.60). The ELISA is the most sensitive method for the detection of antibodies. The specificity of the Toxo-ELISA has to be improved by application of suitable fractions of antigens.

  13. Flexural Behavior of Aluminum Honeycomb Core Sandwich Structure

    Science.gov (United States)

    Matta, Vidyasagar; Kumar, J. Suresh; Venkataraviteja, Duddu; Reddy, Guggulla Bharath Kumar

    2017-05-01

    and has more strength. By the power press used as forming method we fabricate the honey comb core and stacking the sheets with adhesive as epoxy resin or laser beam welding and sandwich structure will form with two face sheets. Then the specimen is taken to be tested to know the flexural behaviour by the flexural test as 3 point and 4 pont bend test. After testing of two different tests then we get the force vs displacement curve by this we can know the maximum force and by loading configurations and its displacement or deflection then we can calculate flexural stiffness and core shear modulus by the variation of three parameters. Our ultimate aim is to achieve maximum strength by minimum weight.

  14. Frequency of antiphospholipid antibodies in patients with infectious diseases using three different ELISA methods Freqüência de anticorpos antifosfolípides em pacientes com doenças infecciosas usando três diferentes testes de ELISA

    Directory of Open Access Journals (Sweden)

    Mittermayer Barreto Santiago

    2006-02-01

    Full Text Available OBJECTIVE: The standard enzyme-linked immunosorbent assay (ELISA for anticardiolipin (aCL antibodies is the most important test for the diagnosis of antiphospholipid syndrome (APS. However, the test is also positive in some infectious diseases and other non-related syndromes. It has been suggested that the detection of antibodies to a mixture of phospholipids or to beta2-glycoprotein I (beta2-GP I has higher specificity for APS than the standard aCL ELISA. The aim of the present work is to compare the diagnostic specificity of three different antiphospholipid (aPL assays in patients with infectious diseases. METHODS: Antiphospholipid antibodies were searched by three ELISA techniques, namely standard aCL, APhL® ELISA kit and anti-beta2-GP I, in sera of patients with infectious diseases, including syphilis (69, leptospirosis (33 and visceral leishmaniasis (30. RESULTS: The frequency of positivity of IgG aPL in patients with syphilis, leptospirosis and Kala-azar was 13/69 (19%, 9/33 (27% and 2/30 (6%, respectively, using standard ELISA, versus only 1/69 (1.4%, 0/33 (0% and 0/30 (0% positivity by the APhL® ELISA kit. The positivity of the isotype IgM aPL was 10/69 (14%, 4/33 (12% and 1/30 (3%, respectively, by the standard ELISA, and 1/69 (1.4%, 0/33 (0% and 0/30 (0% by the APhL® ELISA kit. The presence of significant levels of IgG anti-beta2GPI was observed in 14/69 cases of syphilis (20%, 6/33 cases of leptospirosis (18% and 16/30 cases of Kala-azar (53%. The APhL® ELISA kit had superior performance showing the highest specificity: 97% (95% CI: 92%-99% for IgG compared to 81% (95% CI: 74%-87% for standard ELISA and 72% (95% CI: 64%-79% for anti-beta2 GPI assay. CONCLUSIONS: The APhL® ELISA kit proved to be significantly more specific than the aCL standard ELISA and the anti-beta2GPI ELISA, and it should be used to help in the diagnosis and confirmation of APS.OBJETIVO: O ensaio de enzyme-linked immunosorbent assay (ELISA para a pesquisa de

  15. Development and evaluation of an ELISA for human trefoil factor 3

    DEFF Research Database (Denmark)

    Vestergaard, Else Marie; Poulsen, Steen Seier; Grønbaek, Henning

    2002-01-01

    are warranted. METHODS: An ELISA was developed that uses two antibodies from rabbits immunized with recombinant human TFF3 and a calibrator (3-100 pmol/L) prepared from recombinant human TFF3. RESULTS: The ELISA had a detection limit of 3.0 pmol/L. The imprecision (CV) was 5-9% for mean concentrations of 13...... exacerbation of chronic inflammatory bowel disease restricted to the colon, normal concentrations and only minor variations during treatment and tapering were observed. CONCLUSIONS: The ELISA measures TFF3 in human serum and represents a specific and precise method for measurement of TFF3, which...

  16. Failure Predictions of Out-of-Autoclave Sandwich Joints with Delaminations Under Flexure Loads

    Science.gov (United States)

    Nordendale, Nikolas A.; Goyal, Vinay K.; Lundgren, Eric C.; Patel, Dhruv N.; Farrokh, Babak; Jones, Justin; Fischetti, Grace; Segal, Kenneth N.

    2015-01-01

    An analysis and a test program was conducted to investigate the damage tolerance of composite sandwich joints. The joints contained a single circular delamination between the face-sheet and the doubler. The coupons were fabricated through out-of-autoclave (OOA) processes, a technology NASA is investigating for joining large composite sections. The four-point bend flexure test was used to induce compression loading into the side of the joint where the delamination was placed. The compression side was chosen since it tends to be one of the most critical loads in launch vehicles. Autoclave cure was used to manufacture the composite sandwich sections, while the doubler was co-bonded onto the sandwich face-sheet using an OOA process after sandwich panels were cured. A building block approach was adopted to characterize the mechanical properties of the joint material, including the fracture toughness between the doubler and face-sheet. Twelve four-point-bend samples were tested, six in the sandwich core ribbon orientation and six in sandwich core cross-ribbon direction. Analysis predicted failure initiation and propagation at the pre-delaminated location, consistent with experimental observations. A building block approach using fracture analyses methods predicted failure loads in close agreement with tests. This investigation demonstrated a small strength reduction due to a flaw of significant size compared to the width of the sample. Therefore, concerns of bonding an OOA material to an in-autoclave material was mitigated for the geometries, materials, and load configurations considered.

  17. Evaluation of accuracy and uncertainty of ELISA assays for the determination of interleukin-4, interleukin-5, interferon-gamma and tumor necrosis factor-alpha

    DEFF Research Database (Denmark)

    Borg, Lone; Kristiansen, Jesper; Christensen, Jytte M

    2002-01-01

    . However, models for establishing the traceability and uncertainty of immunoassay results are lacking. Sandwich enzyme-linked immunosorbent assays (ELISAs) were developed for determination of the human cytokines interleukin-4 (IL-4), interleukin-5 (IL-5), interferon-y (IFN-gamma) and tumor necrosis factor-alpha...... (TNF-alpha). The accuracy of each of the assays was evaluated in the ranges of 1-15 microg/l (IL-4), 0.001-1 microg/l (IL-5), 0.5-2.5 microg/l (IFN-T) and 0.14-2.2 microg/l (TNF-alpha). Other evaluated performance characteristics were the limit of detection (LOD), immunological specificity......) of the assessed ELISAs was found to be in the range of 11-18%, except for IL-5 where RSDA increased at decreasing concentrations. The LOD was 0.12 microg/l, 0.0077 microg/l, 0.0069 microg/l and 0.0063 microg/l for IL-4, IL-5, IFN-gamma and TNF-alpha, respectively. Traceability to the WHO IS was established...

  18. Analysis of Grid-Scored Sandwich Structures of Different Curvatures and Grid Sizes For Wind Turbine Blades

    DEFF Research Database (Denmark)

    Laustsen, Steffen; Thomsen, Ole Thybo; Lund, Erik

    2012-01-01

    The stress and strain field developed locally in-situ the core of grid-scored sandwich structures in wind turbine blades is investigated. Due to the many singularities occurring from the “tri-material corners”, a full 3D analysis of the sandwich structure in terms of the Finite Element Method is ...

  19. Food allergen analysis for processed food using a novel extraction method to eliminate harmful reagents for both ELISA and lateral-flow tests.

    Science.gov (United States)

    Ito, Kaori; Yamamoto, Takayuki; Oyama, Yuriko; Tsuruma, Rieko; Saito, Eriko; Saito, Yoshikazu; Ozu, Takeshi; Honjoh, Tsutomu; Adachi, Reiko; Sakai, Shinobu; Akiyama, Hiroshi; Shoji, Masahiro

    2016-09-01

    Enzyme-linked immunosorbent assay (ELISA) is commonly used to determine food allergens in food products. However, a significant number of ELISAs give an erroneous result, especially when applied to highly processed food. Accordingly, an improved ELISA, which utilizes an extraction solution comprising the surfactant sodium lauryl sulfate (SDS) and reductant 2-mercaptoethanol (2-ME), has been specially developed to analyze food allergens in highly processed food by enhancing analyte protein extraction. Recently, however, the use of 2-ME has become undesirable. In the present study, a new extraction solution containing a human- and eco-friendly reductant, which is convenient to use at the food manufacturing site, has been established. Among three chemicals with different reducing properties, sodium sulfite, tris(3-hydroxypropyl)phosphine, and mercaptoethylamine sodium sulfite was selected as a 2-ME substitute. The protein extraction ability of SDS/0.1 M sodium sulfite solution was comparable to that of SDS/2-ME solution. Next, the ELISA performance for egg, milk, wheat, peanut, and buckwheat was evaluated by using model-processed foods and commercially available food products. The data showed that the SDS/0.1 M sulfite ELISA significantly correlated with the SDS/2-ME ELISA for all food allergens examined (p analysis of food allergens in processed food, showing consistency with the SDS/0.1 M sulfite ELISA results. Accordingly, a harmonized analysis system for processed food comprising a screening LF test and a quantitative ELISA with identical extraction solution has been established. The ELISA based on the SDS/0.1 M sulfite extraction solution has now been authorized as the revised official method for food allergen analysis in Japan.

  20. The evaluation of GM6-based ELISA and ICT as diagnostic methods on a Mongolian farm with an outbreak of non-tsetse transmitted horse trypanosomosis.

    Science.gov (United States)

    Davaasuren, Batdorj; Amgalanbaatar, Tovuu; Musinguzi, Simon Peter; Suganuma, Keisuke; Otgonsuren, Davaajav; Mossaad, Ehab; Narantsatsral, Sandagdorj; Battur, Banzragch; Battsetseg, Badgar; Xuan, Xuenan; Inoue, Noboru

    2017-09-15

    Trypanosoma equiperdum, which is the etiological agent of dourine, spreads through sexual intercourse in equines. Dourine (T. equiperdum) has been reported in Mongolia, where it is considered an economically important disease of horses. T. evansi has also been reported in Mongolian domestic animals. The objective of this study was to evaluate the potential application of recombinant T. evansi GM6 (rTeGM6-4r)-based diagnostic methods on a farm with an outbreak of non-tsetse transmitted horse trypanosomosis. Ninety-seven percent homology was found between the amino acid sequences of T. equiperdum GM6 and the GM6 of another Trypanozoon, which also shared the same cellular localization. This finding suggests the utility of rTeGM6-4r-based serodiagnostic methods for epidemiological studies and the diagnosis of both surra and dourine in Equidae. Fifty blood samples were examined from a herd of horses. The diagnostic value of an rTeGM6-4r-based ELISA and an rTeGM6-4r-based immunochromatographic test (ICT) were measured in comparison to a T. evansi crude antigen-based ELISA, which is a diagnostic method recommended by the OIE. However, this is not a perfect diagnostic method for trypanosomosis. Positive serum samples were detected in 46%, 42% and 28% of the tested horses using an rTeGM6-4r-based ELISA, crude antigen-based ELISA and rTeGM6-4r-based ICT, respectively. The sensitivity of rTeGM6-based ELISA was 81%, the specificity was 79%, and the agreement was moderate. We conclude that rTeGM6-4r-based ELISA and ICT represent alternative options for baseline epidemiological studies and the on-site diagnosis of horse trypanosomoses in the field, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Design and manufacturing of bio-based sandwich structures

    CSIR Research Space (South Africa)

    John, Maya J

    2017-03-01

    Full Text Available The aim of this chapter is to discuss the design and manufacturing of bio-based sandwich structures. As the economic advantages of weight reduction have become mandatory for many advanced industries, bio-based sandwich panels have emerged...

  2. 2004 National Atrazine Occurrence Monitoring Program using the Abraxis ELISA method.

    Science.gov (United States)

    Graziano, Nicole; McGuire, Michael J; Roberson, Alan; Adams, Craig; Jiang, Hua; Blute, Nicole

    2006-02-15

    The goal of this project was to gain a better understanding of atrazine occurrence in the United States by surveying drinking water utilities' sources and finished water for atrazine on a weekly basis for seven months. Atrazine is a contaminant of interest because the United States Environmental Protection Agency (USEPA) has found short-term atrazine exposure above the drinking water maximum contaminant level (MCL) to potentially cause heart, lung, and kidney congestion, low blood pressure, muscle spasms, weight loss, and damage to the adrenal glands. Long-term exposure to atrazine concentrations above the drinking water MCL has been linked to weight loss, cardiovascular damage, retinal and muscle degeneration, and cancer. This survey effort improved upon previously conducted atrazine surveys through intensive, high frequency sampling (participating plants sampled their raw and finished water on a weekly basis for approximately seven months). Such an intensive effort allowed the authors to gain a better understanding of short-term atrazine occurrence and its variability in drinking water sources. This information can benefit the drinking water industry by facilitating (1) better atrazine occurrence management (i.e., awareness when plants may be more susceptible to atrazine), (2) more efficient atrazine control (e.g., effective treatment alternatives and more effective response to atrazine occurrence), and (3) treatment cost reduction (e.g., efficient atrazine control can result in substantial cost savings). Forty-seven drinking watertreatment plants located primarily in the Midwestern United States participated in the survey and sampled their raw and finished water on a weekly basis from March through October. Samples were analyzed using the Abraxis enzyme-linked immunosorbent assay (ELISA) test kit. Confirmation samples for quality assurance/quality control (QA/QC) purposes were analyzed using solid-phase extraction (SPE) followed by gas chromatography mass

  3. Sandwiched Thin-Film Anode of Chemically Bonded Black Phosphorus/Graphene Hybrid for Lithium-Ion Battery.

    Science.gov (United States)

    Liu, Hanwen; Zou, Yuqin; Tao, Li; Ma, Zhaoling; Liu, Dongdong; Zhou, Peng; Liu, Hongbo; Wang, Shuangyin

    2017-09-01

    A facile vacuum filtration method is applied for the first time to construct sandwich-structure anode. Two layers of graphene stacks sandwich a composite of black phosphorus (BP), which not only protect BP from quickly degenerating but also serve as current collector instead of copper foil. The BP composite, reduced graphene oxide coated on BP via chemical bonding, is simply synthesized by solvothermal reaction at 140 °C. The sandwiched film anode used for lithium-ion battery exhibits reversible capacities of 1401 mAh g -1 during the 200th cycle at current density of 100 mA g -1 indicating superior cycle performance. Besides, this facile vacuum filtration method may also be available for other anode material with well dispersion in N-methyl pyrrolidone (NMP). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. The sandwich sign | Mahomed | SA Journal of Radiology

    African Journals Online (AJOL)

    The sandwich sign refers to the sandwiching of mesenteric vessels and fat by enlarged mesenteric nodes on cross-sectional imaging, commonly occurring in lymphoma, but not specific to lymphoma. The sign is radiologically indistinguishable from post-transplant lymphoproliferative disorders. The radiological significance ...

  5. Optimal design of sandwich ribbed flat baffle plates of a circular cylindrical tank

    International Nuclear Information System (INIS)

    Malinowski, Marek; Magnucki, Krzysztof

    2005-01-01

    The subject of this paper is a sandwich ribbed flat baffle plate of a circular cylindrical tank. The paper deals with a problem of optimal thickness of this construction with a soft core. The construction is distinguished by a local axisymmetric pre-springing. The mathematical description is based on the theory of shells with analysis of disturbance of the stress membrane state. The sandwich ribbed flat baffle plate divides the tank into two chambers. One of them is loaded by uniform pressure, while the other is empty and unloaded. Dimensions of ribs, faces and the entire baffle plate have been determined with a view to minimize the mass under strength constraints. The effect of optimal thickness of this sandwich plate has been examined by means of the finite element method

  6. DETECTION OF SERIAL SERUM P-185 LEVEL IN PATIENTS WITH MALIGNANCY USING ELISA

    Institute of Scientific and Technical Information of China (English)

    ZHANG Zhi-hui; WU Ping; LI Li; MIAO Yi-meng; LI Jun

    2006-01-01

    Objective: To investigate P-185 contents in serum of the normal person and cancer patients and it's the significance on prognosis of diseases. Methods: We used ELISA method to evaluate P-185 levels in 193 normal persons, 133 malignancies and 34 hepatocirrhosises were evaluated using ELISA method. Results: Normal person had lower expression of P-185. However, malignancy and hepatocirrhosis patients had a significantly higher expression level of P-185 than normal (P<0.05). Conclusion: ELISA method is an easy and reliable way to measure the level of P-185 in serum. Being a cancer marker, P-185 overexpression can be used for early diagnosis and prognosis of cancer patients.

  7. Feasibility study of a SiC sandwich neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jian, E-mail: caepwujian@163.com [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province (China); Lei, Jiarong, E-mail: jiarong_lei@163.com [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province (China); Jiang, Yong; Chen, Yu; Rong, Ru; Zou, Dehui; Fan, Xiaoqiang [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province (China); Chen, Gang; Li, Li; Bai, Song [Nanjing Electronic Devices Institute, Nanjing 210016 (China)

    2013-04-21

    Semiconductor sandwich neutron spectrometers are suitable for in-pile measurements of fast reactor spectra thanks to their compact and relatively simple design. We have assembled and tested a sandwich neutron spectrometer based on 4H-silicon carbide (4H-SiC) Schottky diodes. The SiC diodes detect neutrons via neutron-induced charged particles (tritons and alpha particles) produced by {sup 6}Li(n,α){sup 3}H reaction. {sup 6}LiF neutron converter layers are deposited on the front surface of Schottky diodes by magnetron sputtering. The responses of SiC diodes to charged particles were investigated with an {sup 241}Am alpha source. A sandwich neutron spectrometer was assembled with two SiC Schottky diodes selected based on the charged-particle-response experimental results. The low-energy neutron response of the sandwich spectrometer was measured in the neutron field of the Chinese Fast Burst Reactor-II (CFBR-II). Spectra of alpha particles and tritons from {sup 6}Li(n,α){sup 3}H reaction were obtained with two well-resolved peaks. The energy resolution of the sum spectrum was 8.8%. The primary experimental results confirmed the 4H-SiC sandwich neutron spectrometer's feasibility. -- Highlights: ► Sandwich neutron spectrometer employing 4H-SiC as a detecting material has been developed for the first time. ► {sup 6}LiF neutron converter has been deposited on the surface of 4H-SiC Schottky diode. ► Preliminary testing results obtained with the 4H-SiC sandwich neutron spectrometer are presented.

  8. Theoretical prediction on corrugated sandwich panels under bending loads

    Science.gov (United States)

    Shu, Chengfu; Hou, Shujuan

    2018-05-01

    In this paper, an aluminum corrugated sandwich panel with triangular core under bending loads was investigated. Firstly, the equivalent material parameters of the triangular corrugated core layer, which could be considered as an orthotropic panel, were obtained by using Castigliano's theorem and equivalent homogeneous model. Secondly, contributions of the corrugated core layer and two face panels were both considered to compute the equivalent material parameters of the whole structure through the classical lamination theory, and these equivalent material parameters were compared with finite element analysis solutions. Then, based on the Mindlin orthotropic plate theory, this study obtain the closed-form solutions of the displacement for a corrugated sandwich panel under bending loads in specified boundary conditions, and parameters study and comparison by the finite element method were executed simultaneously.

  9. The Effect of Different Methods of Fermentation on the Detection of Milk Protein Residues in Retail Cheese by Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Ivens, Katherine O; Baumert, Joseph L; Hutkins, Robert L; Taylor, Steve L

    2017-11-01

    Milk and milk products are among the most important allergenic food ingredients, both in the United States and throughout the world; cheeses are among the most important of these milk products. Milk contains several major antigenic proteins, each with differing susceptibilities to proteolytic enzymes. The extent of proteolysis in cheese varies as a result of conditions during manufacture and ripening. Proteolysis has the potential to degrade antigenic and allergenic epitopes that are important for residue detection and elicitation of allergic reactions. Commercial enzyme-linked immunosorbent assays (ELISAs) are not currently validated for use in detecting residues in hydrolyzed or fermented food products. Eighteen retail cheeses produced using 5 different styles of fermentation were investigated for detectable milk protein residues with 4 commercial ELISA kits. Mozzarella, Swiss, Blue, Limburger, and Brie cheeses were assessed. The Neogen Veratox® Casein and Neogen Veratox® Total Milk kits were capable of detecting milk residues in most cheeses evaluated, including blue-veined cheeses that exhibit extensive proteolysis. The other 2 ELISA kits evaluated, r-Biopharm® Fast Casein and ELISA Systems™ Casein, can detect milk residues in cheeses other than blue-veined varieties. ELISA results cannot be quantitatively compared among kits. The quantitative reliability of ELISA results in detection of cheese residues is questionable, but some methods are sufficiently robust to use as a semi-quantitative indication of proper allergen control for the validation of cleaning programs in industry settings. Many commercially available enzyme-linked immunosorbent assays (ELISAs) are not validated for detection of allergenic residues in fermented or hydrolyzed products. This research seeks to determine if commercial milk ELISAs can detect milk residues in varieties of cheese that have undergone different styles of fermentation and different degrees of proteolysis. Only certain

  10. The current preference for the immuno-analytical ELISA method for quantitation of steroid hormones (endocrine disruptor compounds) in wastewater in South Africa.

    Science.gov (United States)

    Manickum, Thavrin; John, Wilson

    2015-07-01

    The availability of national test centers to offer a routine service for analysis and quantitation of some selected steroid hormones [natural estrogens (17-β-estradiol, E2; estrone, E1; estriol, E3), synthetic estrogen (17-α-ethinylestradiol, EE2), androgen (testosterone), and progestogen (progesterone)] in wastewater matrix was investigated; corresponding internationally used chemical- and immuno-analytical test methods were reviewed. The enzyme-linked immunosorbent assay (ELISA) (immuno-analytical technique) was also assessed for its suitability as a routine test method to quantitate the levels of these hormones at a sewage/wastewater treatment plant (WTP) (Darvill, Pietermaritzburg, South Africa), over a 2-year period. The method performance and other relevant characteristics of the immuno-analytical ELISA method were compared to the conventional chemical-analytical methodology, like gas/liquid chromatography-mass spectrometry (GC/LC-MS), and GC-LC/tandem mass spectrometry (MSMS), for quantitation of the steroid hormones in wastewater and environmental waters. The national immuno-analytical ELISA technique was found to be sensitive (LOQ 5 ng/L, LOD 0.2-5 ng/L), accurate (mean recovery 96%), precise (RSD 7-10%), and cost-effective for screening and quantitation of these steroid hormones in wastewater and environmental water matrix. A survey of the most current international literature indicates a fairly equal use of the LC-MS/MS, GC-MS/MS (chemical-analytical), and ELISA (immuno-analytical) test methods for screening and quantitation of the target steroid hormones in both water and wastewater matrix. Internationally, the observed sensitivity, based on LOQ (ng/L), for the steroid estrogens E1, E2, EE2, is, in decreasing order: LC-MSMS (0.08-9.54) > GC-MS (1) > ELISA (5) (chemical-analytical > immuno-analytical). At the national level, the routine, unoptimized chemical-analytical LC-MSMS method was found to lack the required sensitivity for meeting environmental

  11. The equivalent thermal conductivity of lattice core sandwich structure: A predictive model

    International Nuclear Information System (INIS)

    Cheng, Xiangmeng; Wei, Kai; He, Rujie; Pei, Yongmao; Fang, Daining

    2016-01-01

    Highlights: • A predictive model of the equivalent thermal conductivity was established. • Both the heat conduction and radiation were considered. • The predictive results were in good agreement with experiment and FEM. • Some methods for improving the thermal protection performance were proposed. - Abstract: The equivalent thermal conductivity of lattice core sandwich structure was predicted using a novel model. The predictive results were in good agreement with experimental and Finite Element Method results. The thermal conductivity of the lattice core sandwich structure was attributed to both core conduction and radiation. The core conduction caused thermal conductivity only relied on the relative density of the structure. And the radiation caused thermal conductivity increased linearly with the thickness of the core. It was found that the equivalent thermal conductivity of the lattice core sandwich structure showed a highly dependent relationship on temperature. At low temperatures, the structure exhibited a nearly thermal insulated behavior. With the temperature increasing, the thermal conductivity of the structure increased owing to radiation. Therefore, some attempts, such as reducing the emissivity of the core or designing multilayered structure, are believe to be of benefit for improving the thermal protection performance of the structure at high temperatures.

  12. Conversion of a Capture ELISA to a Luminex xMAP Assay using a Multiplex Antibody Screening Method

    Science.gov (United States)

    Baker, Harold N.; Murphy, Robin; Lopez, Erica; Garcia, Carlos

    2012-01-01

    consumables necessary for coupling beads to the capture antibody of interest. (See Materials section for a detailed list of kit contents.) In this experiment, we convert a pre-optimized ELISA assay for TNF-alpha cytokine to the xMAP platform and compare the performance of the two methods 7-11. TNF-alpha is a biomarker used in the measurement of inflammatory responses in patients with autoimmune disorders. We begin by coupling four candidate capture antibodies to four different microsphere sets or regions. When mixed together, these four sets allow for the simultaneous testing of all four candidates with four separate detection antibodies to determine the best antibody pair, saving reagents, sample and time. Two xMAP assays are then constructed with the two most optimal antibody pairs and their performance is compared to that of the original ELISA assay in regards to signal strength, dynamic range, and sensitivity. PMID:22806215

  13. Residual Strength Prediction of Debond Damaged Sandwich Panels

    DEFF Research Database (Denmark)

    Berggreen, Carl Christian

    followed by debond growth. The developed theoretical procedure is an extension of the Crack Surface Displacement method, here denoted the Crack Surface Displacement Extrapolation method. The method is first developed in 2D and then extended to 3D by use of a number of realistic assumptions...... for the considered configurations. Comparison of the theoretical predictions to two series of large-scale experiments with loadings (uniform and non-uniform in-plane compression) comparable with real life loading scenarios for sandwich ships shows that the model is indeed able to predict the failure modes...

  14. ANALISA TEKNIS DAN EKONOMIS PENGGUNAAN COREMAT UNTUK KONSTRUKSI FRP (FIBERGLASS REINFORCED PLASTIC SANDWICH PADA BADAN KAPAL

    Directory of Open Access Journals (Sweden)

    Parlindungan Manik

    2012-02-01

    Full Text Available Planning of ship construction is make its having good effectivity value and efficiency. Composite as materialalternative to changes of steel feedstock and wood has many applied named FRP (fiberglass reinforcedplastics single skin. The weakness of this FRP was heavy construction and requires many production time.Therefore, will be checked comparison between single skin with sandwich constructions for shell.In this research, the way for making composite is hand lay up method with three various thickness of skinthere are : t, t/2, and t/4. To know strength comparison from the various skin of sandwich with single skin,must be test, consist of tensile test.. The result is analyzed then compared by BKI (Biro Klasifikasi Indonesiarules for the fiberglass ship.Based on the result, indicates that optimization skin thickness of sandwich construction applies Corematwhich tensile strength it is equivalent with Single Skin at 2/3t and usage of Sandwich construction causes23,12 % lighter. In economic analyze, advantage from low weight is compensation of addition 23,12 % DWT.Material cost for Sandwich about 11,35% bigger than Single Skin construction.

  15. Highly efficient construction of oriented sandwich structures for surface-enhanced Raman scattering

    International Nuclear Information System (INIS)

    Guo Hongyun; Xu Weiqing; Xu Shuping; Zhou Ji; Lombardi, John R

    2013-01-01

    The purpose of this study is to solve the problem of low achievement in fabricating sandwich surface-enhanced Raman scattering (SERS) substrates. We demonstrated a highly efficient sandwich structure by the oriented assembly of metal nanoparticles (NPs) on a periodic hexagonal array of metal nanoprisms with 1,4-benzenedithiol (1,4-BDT) as linkers. The metal nanoprism array was prepared by vacuum deposition of metal on a close-packed polystyrene nanosphere pre-patterned substrate. The metal nanoprism array presents different surface properties from the pits left from the removal of polystyrene nanospheres, which causes linkers to selectively adsorb on the metal nanoprism array and sequentially leads to the oriented immobilization of the second-layer metal NPs, avoiding mismatched orientation. These sandwich SERS substrates were characterized by extinction spectroscopy and atomic force microscopy and their enhancement activity was evaluated under different excitation wavelengths. The sandwich structure greatly increases the achievement of ‘hot spots’ to almost 100% of all the metal nanoprisms and enables a large amplification of SERS signals by a factor of ten. This method has the advantages of simplicity, high efficiency, high throughput, controllability and high reproducibility. It has significance in both the study of SERS substrates and the development of plasmonic devices. (paper)

  16. Density functional study of isoguanine tetrad and pentad sandwich complexes with alkali metal ions.

    Science.gov (United States)

    Meyer, Michael; Steinke, Thomas; Sühnel, Jürgen

    2007-02-01

    Isoguanine tetraplexes and pentaplexes contain two or more stacked polyads with intercalating metal ions. We report here the results of a density functional study of sandwiched isoguanine tetrad and pentad complexes consisting of two polyads with Na(+), K(+) and Rb(+) ions at the B3LYP level. In comparison to single polyad metal ion complexes, there is a trend towards increased non-planarity of the polyads in the sandwich complexes. In general, the pentad sandwiches have relatively planar polyad structures, whereas the tetrad complexes contain highly non-planar polyad building blocks. As in other sandwich complexes and in metal ion complexes with single polyads, the metal ion-base interaction energy plays an essential role. In iG sandwich structures, this interaction energy is slightly larger than in the corresponding guanine sandwich complexes. Because the base-base interaction energy is even more increased in passing from guanine to isoguanine, the isoguanine sandwiches are thus far the only examples where the base-base interaction energy is larger than the base-metal ion interaction energy. Stacking interactions have been studied in smaller models consisting of two bases, retaining the geometry from the complete complex structures. From the data obtained at the B3LYP and BH&H levels and with Møller-Plesset perturbation theory, one can conclude that the B3LYP method overestimates the repulsion in stacked base dimers. For the complexes studied in this work, this is only of minor importance because the direct inter-tetrad or inter-pentad interaction is supplemented by a strong metal ion-base interaction. Using a microsolvation model, the metal ion preference K(+) approximately Rb(+) > Na(+) is found for tetrad complexes. On the other hand, for pentads the ordering is Rb(+) > K(+) > Na(+). In the latter case experimental data are available that agree with this prediction.

  17. Field trial of brucellosis competitive ELISA

    International Nuclear Information System (INIS)

    Perez, B.; Rojas, M.

    1998-01-01

    2990 sera samples from cattle were tested for antibodies to Brucella abortus using 8 serological tests for. The tests used were Rose Bengal (RBT), Buffer Plate Agglutination Test (BPAT), Complement Fixation (CFT), 2 Indirect and 2 Competitive Enzyme Linked Immunosorbent Assays (ELISA). Bacteriological evaluation from milk was done also. All tests were compared with respect to diagnostic specificity in vaccinated herds which were considered to be Brucella-free. The diagnostic specificity of the Indirect and Competitive ELISA was greater than 99,8%. Estimates of relative sensitivity were obtained from infected herds. The diagnostic sensitivity of the Indirect ELISA was greater than 95,8% and for the Competitive ELISA between 98,8 and 100 %, the last value refers to the Competitive ELISA Prototype II (SLPS antigen/M84 Mab), which was found highly suitable to differentiate vaccinated from brucella-infected cattle. The use of C-ELISA II for monitoring bovine populations under an eradication programme is recommended. (author)

  18. Fracture Analysis of Debonded Sandwich Columns Under Axial Compression

    DEFF Research Database (Denmark)

    May, A.; Avilés, F.; Berggreen, Christian

    A sandwich structure consists of two strong and stiff face sheets bonded to a weak low density core. The large separation between the face sheets provides increased bending rigidity and strength at low weight cost. Thus, sandwich structures frequently present better mechanical properties than...... monolithic structures of the same weight. The vast range of applications of such materials includes wind turbines, marine, and aerospace industries. In this work, geometrically nonlinear finite element analysis is conducted to investigate the fracture parameters and debond propagation of sandwich columns...

  19. Porous Sandwiched Graphene/Silicon Anodes for Lithium Storage

    International Nuclear Information System (INIS)

    Wei, Liangming; Hou, Zhongyu; Wei, Hao

    2017-01-01

    Highlights: • In situ hydrolysis of tetraethoxysilane within the confined galleries region of graphite oxide. • New porous sandwiched graphene/Si nanocomposites were prepared by magnesium thermal reduction. • The Si nanostructure was compactly sandwiched between two neighboring graphenes. • The Si/graphene anodes deliver large reversible capacity with excellent cycling stability. - Abstract: Porous sandwiched graphene/Si nanocomposites (PG-Si) are prepared by in situ hydrolysis of tetraethoxysilane within the confined gallery region of graphite oxide, and then magnesium thermal reduction of the intra-gallery SiO 2 to Si nanocrystals. The Si nanostructures are in situ formed within the confined gallery region of graphite, and they are compactly sandwiched between two neighboring graphene sheets. This compactly sandwiched structure affords enhanced electron conductivity, and prevents Si nanoparticles from aggregation. Meanwhile, the free voids between neighboring Si nanocrystals alleviate the volume change of Si during cycling. As a consequence, the resulting PG-Si nanocomposites are high-performance anode materials for lithium-ion batteries which show long cycle life (>500 cycles) and high specific charge capacity (1464 mAh g −1 at a current density of 200 mA/g, 920 mAh g −1 at a current density of 1.68A/g after 500 cycles). The Li + diffusion kinetics in PG-Si is also discussed.

  20. Production of monoclonal antibodies for sandwich immunoassay detection of ciguatoxin 51-hydroxyCTX3C.

    Science.gov (United States)

    Tsumuraya, Takeshi; Fujii, Ikuo; Inoue, Masayuki; Tatami, Atsushi; Miyazaki, Keisuke; Hirama, Masahiro

    2006-09-01

    Every year, more than 50,000 people in subtropical and tropical regions suffer from ciguatera seafood poisoning. The extremely low level of the causative neurotoxins (ciguatoxins) in fish has hampered the preparation of antibodies for detection of the toxins. In this study, we produced a monoclonal antibody (8H4) against the right end of ciguatoxin CTX1B (1) and 51-hydroxyCTX3C (3) by immunizing mice with the keyhole limpet hemocyanin-conjugate of the synthetic HIJKLM ring fragment (10). We used 8H4 and another previously reported monoclonal antibody (10C9) that recognizes the left end of 3 to develop a sandwich enzyme-linked immunosorbent assay (ELISA) to detect 3. The assay could detect 3 down to the ppb level and lacked cross-reactivity with other related marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, and maitotoxin.

  1. AA, sandwich line with magnetic horn

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    The magnetic horn, focusing the antiprotons emanating from the target, was affixed to a sandwich line through which the 150 kA pulses were supplied. Expecting to have to change from time to time the fragile horn (inner conductor only 0.7 mm thick), the assembly was designed for quick exchange. At the lower end of the sandwich line we see the connectors for the high-current cables, at the upper end the magnet horn. It has just been lifted from the V-supports which held it aligned downstream of the target. Continue with 8010293.

  2. Buckling driven debonding in sandwich columns

    DEFF Research Database (Denmark)

    Østergaard, Rasmus Christian

    2008-01-01

    results from two mechanisms: (a) interaction of local debond buckling and global buckling and (b) the development of a damaged zone at the debond crack tip. Based on the pronounced imperfection sensitivity, the author predicts that an experimental measurement of the strength of sandwich structures may......A compression loaded sandwich column that contains a debond is analyzed using a geometrically non-linear finite element model. The model includes a cohesive zone along one face sheet/core interface whereby the debond can extend by interface crack growth. Two geometrical imperfections are introduced...

  3. Development and application of triple antibody sandwich enzyme-linked immunosorbent assays for begomovirus detection using monoclonal antibodies against Tomato yellow leaf curl Thailand virus.

    Science.gov (United States)

    Seepiban, Channarong; Charoenvilaisiri, Saengsoon; Warin, Nuchnard; Bhunchoth, Anjana; Phironrit, Namthip; Phuangrat, Bencharong; Chatchawankanphanich, Orawan; Attathom, Supat; Gajanandana, Oraprapai

    2017-05-30

    Tomato yellow leaf curl Thailand virus, TYLCTHV, is a begomovirus that causes severe losses of tomato crops in Thailand as well as several countries in Southeast and East Asia. The development of monoclonal antibodies (MAbs) and serological methods for detecting TYLCTHV is essential for epidemiological studies and screening for virus-resistant cultivars. The recombinant coat protein (CP) of TYLCTHV was expressed in Escherichia coli and used to generate MAbs against TYLCTHV through hybridoma technology. The MAbs were characterized and optimized to develop triple antibody sandwich enzyme-linked immunosorbent assays (TAS-ELISAs) for begomovirus detection. The efficiency of TAS-ELISAs for begomovirus detection was evaluated with tomato, pepper, eggplant, okra and cucurbit plants collected from several provinces in Thailand. Molecular identification of begomoviruses in these samples was also performed through PCR and DNA sequence analysis of the CP gene. Two MAbs (M1 and D2) were generated and used to develop TAS-ELISAs for begomovirus detection. The results of begomovirus detection in 147 field samples indicated that MAb M1 reacted with 2 begomovirus species, TYLCTHV and Tobacco leaf curl Yunnan virus (TbLCYnV), whereas MAb D2 reacted with 4 begomovirus species, TYLCTHV, TbLCYnV, Tomato leaf curl New Delhi virus (ToLCNDV) and Squash leaf curl China virus (SLCCNV). Phylogenetic analyses of CP amino acid sequences from these begomoviruses revealed that the CP sequences of begomoviruses recognized by the narrow-spectrum MAb M1 were highly conserved, sharing 93% identity with each other but only 72-81% identity with MAb M1-negative begomoviruses. The CP sequences of begomoviruses recognized by the broad-spectrum MAb D2 demonstrated a wider range of amino acid sequence identity, sharing 78-96% identity with each other and 72-91% identity with those that were not detected by MAb D2. TAS-ELISAs using the narrow-specificity MAb M1 proved highly efficient for the detection of

  4. A chromogranin A ELISA absent of an apparent high-dose hook effect observed in other chromogranin A ELISAs.

    Science.gov (United States)

    Erickson, J Alan; Grenache, David G

    2016-01-15

    Routine testing for chromogranin A (CgA) using an established commercial ELISA revealed an apparent high-dose hook effect in approximately 15% of specimens. Investigations found the same effect in two additional ELISAs. We hypothesized that a CgA derived peptide(s) at high concentrations was responsible but experiments were inconclusive. Here we describe the analytical performance characteristics of the Chromoa™ CgA ELISA that did not display the apparent high-dose hook effect. Performance characteristics of the Chromoa ELISA were assessed. The reference interval was established utilizing healthy volunteers. Specimens producing the apparent high-dose hook effect in other assays were evaluated using the Chromoa ELISA. The limit of detection was 8ng/ml. Linearity was acceptable (slope=1.04, intercept=18.1 and r(2)=0.997). CVs were ≤4.6 and ≤9.3% for repeatability and within-laboratory imprecision, respectively. CgA was stable at ambient and refrigerated temperatures for a minimum of two and 14days, respectively. An upper reference interval limit of 95ng/ml was established. Specimens demonstrating the apparent high-dose hook effect in other ELISAs did not exhibit the phenomenon using the Chromoa ELISA. The Chromoa ELISA demonstrates acceptable performance for quantifying serum CgA. The apparent high-dose hook effect exhibited in other ELISAs was absent using the Chromoa assay. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Development of ELISA-based methods to measure the anti-malarial drug chloroquine in plasma and in pharmaceutical formulations

    Directory of Open Access Journals (Sweden)

    Ronn Anita

    2011-08-01

    Full Text Available Abstract Background In Central and South America and Eastern and Southern Africa, Plasmodium vivax infections accounts for 71-81% and 5% of malaria cases, respectively. In these areas, chloroquine (CQ remains the treatment of choice for P. vivax malaria. In addition, CQ has recently proven to be an effective HIV-1 therapeutic agent. There is a dire need to continue monitoring quality of CQ as there is a major influx of substandard and fake formulations into malaria-endemic countries. The use of fake/substandard drugs will result in sub-therapeutic levels endangering the patient and possibly select for parasite resistance. The aim of this study was to develop an inexpensive, simple antibody-based ELISA to measure CQ concentrations in tablets and in plasma. Methods A monoclonal antibody (MAb that reacts with the N-side chain of the CQ molecule was prepared by use of a CQ analogue. A specific and reliable ELISA for detection of CQ was developed. The developed assay was validated by measuring CQ in tablets sold in Denmark, India and Sudan. Furthermore, kinetics of CQ concentrations in plasma of four volunteers, who ingested two tablets of Malarex® containing, 250 mg CQ base, were measured before drug intake, three hours later and thereafter at days 1, 3, 7, 14, 21 and 28. The same plasma samples were simultaneously measured by high performance liquid chromatography (HPLC. Results The ELISA proved an easy-to-handle and very sensitive tool for the detection of CQ with a lower limit of detection at 3.9 ng/ml. ELISA levels of CQ in plasma showed high agreement with the levels obtained by HPLC (r = 0.98. The specificity in the negative control group was 100%. Conclusion The developed ELISA can be used for quality screening of CQ in pharmaceutical formulations and for drug monitoring in malaria and in other infectious diseases, such as HIV, where CQ proved to be an effective therapeutic agent. The methodology has been exploited to develop monoclonal

  6. Effect of nanomodified polyester resin on hybrid sandwich laminates

    International Nuclear Information System (INIS)

    Anbusagar, NRR.; Giridharan, P.K.; Palanikumar, K.

    2014-01-01

    Highlights: • Effect of nanomodified polyester resin on hybrid sandwich laminates is evaluated. • The hybrid sandwich laminates are fabricated with varying wt% of nanoclay. • Flexural, impact and moisture absorbtion properties are evaluated for hybrid composites. • Scanning electron microscopy is utilized to analyze the dispersion of clay and fractured surfaces of the nanocomposites. - Abstract: Effect of nanoclay modified polyester resin on flexural, impact, hardness and water absorption properties of untreated woven jute and glass fabric hybrid sandwich laminates have been investigated experimentally. The hybrid sandwich laminates are prepared by hand lay-up manufacturing technique (HL) for investigation. All hybrid sandwich laminates are fabricated with a total of 10 layers, by varying the extreme layers and wt% of nanoclay in polyester resin so as to obtain four different combinations of hybrid sandwich laminates. For comparison of the composite with hybrid composite, jute fiber reinforced composite laminate also fabricated. X-ray diffraction (XRD) results obtained from samples with nanoclay indicated that intergallery spacing of the layered clay increases with matrix. Scanning electron microscopy (SEM) gave a morphological picture of the cross-sections and energy dispersive X-ray spectroscopy (EDS) allowed investigating the elemental composition of matrix in composites. The testing results indicated that the flexural properties are greatly increased at 4% of nanoclay loading while impact, hardness and water absorption properties are increased at 6% of nanoclay loading. A plausible explanation for high increase of properties has also been discussed

  7. AN ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA) METHOD FOR THE URINARY BIOMONITORING OF 2,4-DICHLOROPHRENOCYACETIC ACID (2,4-D)

    Science.gov (United States)

    An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline, 0.05% Tween 20, with 0.02% sodium azide, and analyzed by a 96-microwekk pl...

  8. Can a combination of the conformal thin-sandwich and puncture methods yield binary black hole solutions in quasiequilibrium?

    International Nuclear Information System (INIS)

    Hannam, Mark D.; Evans, Charles R.; Cook, Gregory B.; Baumgarte, Thomas W.

    2003-01-01

    We consider combining two important methods for constructing quasiequilibrium initial data for binary black holes: the conformal thin-sandwich formalism and the puncture method. The former seeks to enforce stationarity in the conformal three-metric and the latter attempts to avoid internal boundaries, like minimal surfaces or apparent horizons. We show that these two methods make partially conflicting requirements on the boundary conditions that determine the time slices. In particular, it does not seem possible to construct slices that are quasistationary and that avoid physical singularities while simultaneously are connected by an everywhere positive lapse function, a condition which must be obtained if internal boundaries are to be avoided. Some relaxation of these conflicting requirements may yield a soluble system, but some of the advantages that were sought in combining these approaches will be lost

  9. A Debonded Sandwich Specimen Under Mixed Mode Bending (MMB)

    DEFF Research Database (Denmark)

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, Leif A.

    2008-01-01

    Face/core interface crack propagation in sandwich specimens is analyzed. A thorough analysis of the typical failure modes in sandwich composites was performed in order to design the MMB specimen to promote face/core debond fracture. Displacement, compliance and energy release rate expressions...... for the MMB specimen were derived from a superposition analysis. An experimental verification of the methodology proposed was performed using MMB sandwich specimens with H100 PVC foam core and E-glass/polyester non-crimp quadro-axial [0/45/90/-45]s DBLT-850 faces. Different mixed mode loadings were applied...

  10. Ultrasensitive and accelerated detection of ciguatoxin by capillary electrophoresis via on-line sandwich immunoassay with rotating magnetic field and nanoparticles signal enhancement.

    Science.gov (United States)

    Zhang, Zhaoxiang; Zhang, Chaoying; Luan, Wenxiu; Li, Xiufeng; Liu, Ying; Luo, Xiliang

    2015-08-12

    A sensitive and rapid on-line immunoassay for the determination of ciguatoxin CTX3C was developed based on a capillary mixing system, which was integrated with capillary electrophoresis (CE) separation and electrochemical (EC) detection. In the sandwich immunoassay system, anti-CTX3C-functionalized magnetic nanoparticles were used as immunosensing probes, and horseradish peroxidase (HRP) and anti-CTX3C antibody were bound onto the surface of gold nanoparticles (AuNPs) and used as recognition elements. Online formation of immunocomplex was realized in capillary inlet end with an external rotating magnetic field. Compared with classical HPLC-MS and ELISA, the assay adopting AuNPs as multienzyme carriers and online sandwich immunoassay format with rotating magnetic field exhibited higher sensitivity and shorter assay time. The linear range of the assay for CTX3C was from 0.6 to 150 ng/L with a correlation coefficient of 0.9948 (n = 2), and the detection limit (S/N = 3) was 0.09 ng/L. The developed assay showed satisfying reproducibility and stability, and it was successfully applied for the quantification of CTX3C in fish samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Mycotoxin determination using RIA and ELISA methods

    Energy Technology Data Exchange (ETDEWEB)

    Fukal, L; Sova, Z

    1985-12-01

    Experience is summed up of various authors with the determination of some mycotoxins (aflatoxin, ochratoxin A, T-2 toxin, rubratoxin, zearalenon, sterigmatocystine) using radioimmunoassay and enzyme immunoassay. For RIA purposes, tritium or sometimes iodine 125 is frequently used for labelling mycotoxins. Mycotoxins do not show immunogenic properties and must thus be conjugated with a high-molecular compound (serum albumin, polylysine) prior to immunozation. Factors are discussed making mycotoxin determination in foods difficult. Specificity of the obtained antisera is total between the individual mycotoxin groups while cross reactions are always recorded within the groups. RIA makes it possible to determine down to 200 pg (labelled with /sup 3/H) or 5 pg (labelled with /sup 125/I) of mycotoxins in a standard solution. In addition to high sensitivity and specificity, immunoassays of mycotoxins minimize the quantities of samples and solvents needed for extraction. Large series of samples can be processed using automatic analyzers. ELISA generally is more advantageous than RIA.

  12. Mechanical evaluation with fe analysis of sandwich panels for wind turbine blade

    Energy Technology Data Exchange (ETDEWEB)

    Yasaswi, M.; Naveen, P.N.E.; Prasad, R.V. [GIET. Dept. of Mechanical Engineering, Rajahmundry (India)

    2012-07-01

    Sandwich panels are notable for their structural efficiency and are used as load bearing components in various branches of engineering, especially in aerospace and marine industries. The objective of the present work is to perform computer-aided analysis on sandwich panels. The analysis of sandwich panel with truss core are compared with other four types of sandwich panel with continuous corrugated core, top hat core, zed core and channel core. The basic reason to use sandwich structure is to save weight, however smooth skins and excellent fatigue resistance are also attributes of a sandwich structure. A sandwich is comprised of two layered composite materials formed by bonding two or more thin facings or face sheets to relatively thick core materials. In this type of construction the facings resist nearly all of the in-plane loads and out-of-plane bending moments. The thin facings provide nearly all of the bending stiffness because they are generally of a much higher modulus material is located at a greatest distance from the neutral axis of the component. The basic concept of sandwich panel is that the facings carry the bending loads and the core carries the shear loads. The main function of the core material is to distribute local loads and stresses over large areas. From all this analysis it is concluded that the truss core Sandwich panels can be used in wind turbine blade design. (Author)

  13. Rapid Detection of Food Allergens by Microfluidics ELISA-Based Optical Sensor

    Directory of Open Access Journals (Sweden)

    Xuan Weng

    2016-06-01

    Full Text Available The risks associated with the presence of hidden allergens in food have increased the need for rapid, sensitive, and reliable methods for tracing food allergens in commodities. Conventional enzyme immunosorbent assay (ELISA has usually been performed in a centralized lab, requiring considerable time and sample/reagent consumption and expensive detection instruments. In this study, a microfluidic ELISA platform combined with a custom-designed optical sensor was developed for the quantitative analysis of the proteins wheat gluten and Ara h 1. The developed microfluidic ELISA biosensor reduced the total assay time from hours (up to 3.5 h to 15–20 min and decreased sample/reagent consumption to 5–10 μL, compared to a few hundred microliters in commercial ELISA kits, with superior sensitivity. The quantitative capability of the presented biosensor is a distinctive advantage over the commercially available rapid methods such as lateral flow devices (LFD and dipstick tests. The developed microfluidic biosensor demonstrates the potential for sensitive and less-expensive on-site determination for rapidly detecting food allergens in a complex sample system.

  14. ANALISA TEKNIS DAN EKONOMIS PENGGUNAAN COREMAT UNTUK KONSTRUKSI FRP (FIBERGLASS REINFORCED PLASTIC SANDWICH PADA BADAN KAPAL

    Directory of Open Access Journals (Sweden)

    Parlindungan Manik

    2012-04-01

    Full Text Available Planning of ship construction is make its having good effectivity value and efficiency. Composite as material alternative to changes of steel feedstock and wood has many applied named FRP (fiberglass reinforced plastics single skin. The weakness of this FRP was heavy construction and requires many production time. Therefore, will be checked comparison between single skin with sandwich constructions for shell. In this research, the way for making composite is hand lay up method with three various thickness of skin there are : t, t/2, and t/4. To know strength comparison from the various skin of sandwich with single skin, must be test, consist of tensile test.. The result is analyzed then compared by BKI (Biro Klasifikasi Indonesia rules for the fiberglass ship. Based on the result, indicates that optimization skin thickness of sandwich construction applies Coremat which tensile strength it is equivalent with Single Skin at 2/3t and usage of Sandwich construction causes 23,12 % lighter. In economic analyze, advantage from low weight is compensation of addition 23,12 % DWT. Material cost for Sandwich about 11,35% bigger than Single Skin construction.

  15. Buckling analysis of SMA bonded sandwich structure – using FEM

    Science.gov (United States)

    Katariya, Pankaj V.; Das, Arijit; Panda, Subrata K.

    2018-03-01

    Thermal buckling strength of smart sandwich composite structure (bonded with shape memory alloy; SMA) examined numerically via a higher-order finite element model in association with marching technique. The excess geometrical distortion of the structure under the elevated environment modeled through Green’s strain function whereas the material nonlinearity counted with the help of marching method. The system responses are computed numerically by solving the generalized eigenvalue equations via a customized MATLAB code. The comprehensive behaviour of the current finite element solutions (minimum buckling load parameter) is established by solving the adequate number of numerical examples including the given input parameter. The current numerical model is extended further to check the influence of various structural parameter of the sandwich panel on the buckling temperature including the SMA effect and reported in details.

  16. Fatigue characterization of Poly Vinyl Chloride (PVC) foam core sandwich composite using the G-control method

    DEFF Research Database (Denmark)

    Manca, Marcello; Berggreen, Christian; Carlsson, Leif A.

    2016-01-01

    This paper presents experimental results from cyclic crack propagation tests performed on sandwich specimens with glass/epoxy face sheets and Poly Vinyl Chloride (PVC) foam cores using the G-controlled cyclic energy release rate (ΔG) test procedure. The face material was tested in tension......, compression and shear to determine in-plane and out-of-plane mechanical properties, such as Young’s modulus, Poisson’s ratio and shear modulus. These properties were then used in an analytical model of the mixed-mode bending sandwich specimen to calculate compliance and energy release rate. Finite element...... on tested specimens, highlighting the influence of mode mixity and foam density on the crack path. Crack propagation diagrams showing da/dN versus ΔG curves were obtained to establish the Paris-Erdogan relation for each material combination tested at the two mode-mixities. Results showed constant crack...

  17. Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodies

    Directory of Open Access Journals (Sweden)

    Elza FT Belo

    Full Text Available Dot-ELISA using the outer membrane complex antigens of Neisseria meningitidis as a target was standardized for rapid detection of meningococcal-specific antibodies in human serum. We investigated the level of meningococcal-specific IgG, IgA, and IgM in serum using dot-ELISA with outer membrane antigens prepared from Neisseria meningitidis serotype B:4.19:P1.15,3,7,9 (a strain isolated from a Brazilian epidemic. The dot-ELISA is based on the same principles as the standard ELISA and is useful for detection of anti-N. meningitidis B antibodies in serum of patients with meningococcal infections. For the assay, outer membrane complexes (OMCs were absorbed by nitrocellulose membrane and blocked with a 5% skim milk solution. Serum samples were drawn upon hospital admission and during convalescence from patients with meningococcal septicemia, and single samples were drawn from uninfected controls. We retrospectively examined a total of 57 serum samples: 35 from patients infected with N. meningitidis B, 12 from patients infected with Haemophilus influenzae b, and 10 from health individuals. When performed at room temperature, dot-ELISA took approximately four hours to perform, and the optimum antigen concentration was 0.42 µg per dot. The specificity of IgG, IgM, and IgA demonstrates that dot-ELISA using OMCs from N. meningitidis B as a target is suitable for serologic verification of clinically suspected meningococcal disease in patients and for titer determination of antibodies produced during different phases of natural infection. Furthermore, the sensitivity of dot-ELISA was comparable to that of standard ELISA. Overall, dot-ELISA is simple to perform, rapid, and low cost. Further validation of the test as a screening tool is required.

  18. Development and Validation of an ELISA at Acidic pH for the Quantitative Determination of IL-13 in Human Plasma and Serum

    Directory of Open Access Journals (Sweden)

    Julie Doucet

    2013-01-01

    Full Text Available A novel sandwich ELISA for the quantitative and sensitive determination of IL-13 in human serum and plasma was established. The assay employs an incubation step at acidic pH, which was shown to decrease nonspecific binding and interference from IL-13 binding proteins. The assay was validated and was shown to be accurate and precise over the entire quantification range (0.59 to 68.4 pg/mL in human EDTA plasma. The validated assay was successfully applied to samples from healthy volunteers and patients with atopic seasonal rhinitis. The assay is suitable for use in clinical trials to monitor efficacy or pharmacodynamic effects of drug candidates.

  19. Adhesion aspects of polyurethane foam sandwich panels.

    OpenAIRE

    Ng, Simon L.

    2016-01-01

    Sandwich panels, polyurethane foam sandwiched between two sheets of steel, form the walls and roofs in the construction of buildings. ArcelorMittal is a manufacturer of the steel as well as these finished panels. For this project they combined with a supplier of the polyurethane foams, Huntsman Polyurethanes, to joint-fund a research project investigating the fundamental mechanisms of adhesion, as well as the causes of failures in the product which manifests primarily in two different ways...

  20. Detecting Pathogens of Verticillium Wilt in Winter Oilseed Rape Using ELISA and PCR – Comparison of the Two Methods and With Visual Stand Evaluation

    Directory of Open Access Journals (Sweden)

    Tomáš Spitzer

    2017-01-01

    Full Text Available During 2013–2015, oilseed rape samples from various locations in the Czech Republic were analysed for the presence of Verticillium wilt. Samples were evaluated in the lab using ELISA and PCR as well as by visual evaluation during the samples collection. A comparison of detection match in individual methods also was made. ELISA and PCR matched in detecting Verticillium wilt in 60 % of cases. For practical use, a higher match rate would be necessary in cases where samples were to be analysed in various laboratories using only one of these techniques. The possibility was demonstrated to use kits as well as primers not targeted specifically to just Verticillium longisporum but recording both main species on oilseed rape (V. longisporum and V. dahliae. The match rates of lab analyses with visual evaluation of stand infection were surprisingly high at 62 % for ELISA and 77 % for PCR. All three stand evaluation methods matched in 56 % of cases.

  1. Comparative evaluation of competitive ELISA test in Colombian cattle

    International Nuclear Information System (INIS)

    Marino, O.; Rueda, E.; Sedano, L.; Zuniga, I.; Calderon, C.; Ortega, A.; Puentes, A.

    1998-01-01

    hypothesis that the ELISA methodology designed for brucellosis will provide more precise and standardised method for diagnosis and for the support of control and eradication campaigns. (author)

  2. Impact properties of aluminium - glass fiber reinforced plastics sandwich panels

    Directory of Open Access Journals (Sweden)

    Mathivanan Periasamy

    2012-06-01

    Full Text Available Aluminium - glass fiber reinforced plastics (GFRP sandwich panels are hybrid laminates consisting of GFRP bonded with thin aluminum sheets on either side. Such sandwich materials are increasingly used in airplane and automobile structures. Laminates with varying aluminium thickness fractions, fiber volume fractions and orientation in the layers of GFRP were fabricated by hand lay up method and evaluated for their impact performance by conducting drop weight tests under low velocity impacts. The impact energy required for initiating a crack in the outer aluminium layer as well as the energy required for perforation was recorded. The impact load-time history was also recorded to understand the failure behavior. The damage depth and the damage area were measured to evaluate the impact resistance. Optical photography and scanning electron micrographs were taken to visualize the crack and the damage zone. The bidirectional cross-ply hybrid laminate (CPHL has been found to exhibit better impact performance and damage resistance than the unidirectional hybrid laminate (UDHL. Increase in aluminium thickness fraction (Al tf and fiber volume fraction (Vf resulted in an increase in the impact energy required for cracking and perforation. On an overall basis, the sandwich panels exhibited better impact performance than the monolithic aluminium.

  3. The Thoc1 Ribonucleoprotein as a Novel Biomarker for Prostate Cancer Treatment Assignment

    Science.gov (United States)

    2016-10-01

    successfully developed (PI Goodrich). A sandwich ELISA assay has been developed for detecting Thoc1 protein in serum samples. Recombinant Thoc1... protein was produced in E.coli and purified by affinity chromatography. This control 5 protein was used to develop the sandwich ELISA assay , and a...standard curve using the assay is shown in figure 4. An indirect ELISA assay was developed for detecting autoantibodies against Thoc1 protein in serum

  4. Rapid screening for glucose-6-phosphate dehydrogenase deficiency and haemoglobin polymorphisms in Africa by a simple high-throughput SSOP-ELISA method

    DEFF Research Database (Denmark)

    Enevold, Anders; Vestergaard, Lasse S; Lusingu, John

    2005-01-01

    was available. METHODS: A simple and rapid technique was developed to detect the most prominent single nucleotide polymorphisms (SNPs) in the HbB and G6PD genes. The method is able to detect the different haemoglobin polymorphisms A, S, C and E, as well as G6PD polymorphisms B, A and A- based on PCR......-amplification followed by a hybridization step using sequence-specific oligonucleotide probes (SSOPs) specific for the SNP variants and quantified by ELISA. RESULTS: The SSOP-ELISA method was found to be specific, and compared well to the commonly used PCR-RFLP technique. Identical results were obtained in 98......% (haemoglobin) and 95% (G6PD) of the tested 90 field samples from a high-transmission area in Tanzania, which were used to validate the new technique. CONCLUSION: The simplicity and accuracy of the new methodology makes it suitable for application in settings where resources are limited. It would serve...

  5. SIMPLIFIED DIAGNOSIS OF MALARIA INFECTION: GFM/PCR/ELISA A SIMPLIFIED NUCLEIC ACID AMPLIFICATION TECHNIQUE BY PCR/ELISA

    Directory of Open Access Journals (Sweden)

    Ricardo Luiz Dantas MACHADO

    1998-09-01

    Full Text Available We report an adaptation of a technique for the blood sample collection (GFM as well as for the extraction and amplification of Plasmodium DNA for the diagnosis of malaria infection by the PCR/ELISA. The method of blood sample collection requires less expertise and saves both time and money, thus reducing the cost by more than half. The material is also suitable for genetic analysis in either fresh or stored specimens prepared by this method.Relatamos a adaptação de uma técnica para coleta de amostras (MFV e outra para extração, amplificação de DNA de parasitas da malária para diagnóstico por PCR/ELISA. O método de coleta de amostras requer menos habilidade e economisa tempo e dinheiro, assim reduzindo a mais da metade o custo. O material é também adequado para análise genética em especimens frescos ou estocados, preparados por este método.

  6. Enhanced electrochemical performance from 3DG/LiFePO4/G sandwich cathode material

    Science.gov (United States)

    Du, Yahui; Tang, Yufeng; Chang, Chengkang

    2017-08-01

    In this paper, we have successfully synthesized a three dimensional graphene/LiFePO4/graphene (3DG/LFP/G) sandwich composite by an in-situ hydrothermal method, in which chemical vapor deposited 3D graphene acts as the high conductivity supporting framework, while the LiFePO4 nanoparticles are anchored onto the 3D graphene framework covered by graphene sheets. XRD and SEM results confirmed the formation of the 3DG/LFP/G sandwich composite. Cyclic Voltammetry curve of the sandwich composite shows sharper redox peaks and reduced voltage separation when compared to the reference electrodes, suggesting high specific capacity and good rate performance. Further charge/discharge measurements presented high capacity of 164 mAh g-1 at 0.2 C and 124 mAh g-1 at 10 C (75.7% of its initial capacity) for the sandwich composite, with capacity retention of 95.7% after 100 cycles, implying potential application in lithium ion battery at high rates. The EIS investigation suggests that both the electronic conductivity and the Li ion diffusion are promoted by the underlined 3D graphene framework, which is regarded as the reason for the enhanced electrochemical performance.

  7. The use of enzyme-linked immunosorbent assay (ELISA) for the diagnosis and monitoring of foot-and-mouth disease in the Philippines

    International Nuclear Information System (INIS)

    Verin, B.C.; Arvesu, R.M.

    2000-01-01

    The establishment and use of the indirect sandwich ELISA for the detection of foot-and-mouth disease (FMD) virus antigen sero-types O, A and C and the liquid phase blocking ELISA (LPB-ELISA) for antibody levels against similar FMD sero-types has been adopted for routine diagnosis at the FMD diagnostic laboratory, PAHC. A total of 552 epithelial samples and 4401 serum samples were tested starting 1995 to 1998. Out of 552, 84 (17.9%) were found negative and 468 (84.78%) diagnosed as positive for sero-types O and C (42% of the total positives). Within 4 years, 62 representative samples were sent to WRL for FMD for confirmation diagnosis. From 62 samples sent 54 (87%) were diagnosed as positive and 8 (12.9%) were negative. Serum samples received were either for diagnosis (71 samples), surveillance (3002 serum), post vaccination titre (1303 serum) and for the FAO/IAEA external quality assurance programme (25 samples) by the FAO/IAEA Co-ordinated Research Project on FMD. The assay has been a useful tool in the fast diagnosis and confirmation of FMD suspect cases and in the measurement of antibodies against FMDV in serum samples from all animals either vaccinated or infected. In the future, the assay will be use for potency testing of imported vaccines and for monitoring and surveillance purposes to show freedom from disease for the support documentation from OIE. (author)

  8. High sensitivity, high surface area Enzyme-linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Singh, Harpal; Morita, Takahiro; Suzuki, Yuma; Shimojima, Masayuki; Le Van, An; Sugamata, Masami; Yang, Ming

    2015-01-01

    Enzyme-linked immunosorbent assays (ELISA) are considered the gold standard in the demonstration of various immunological reactions with an application in the detection of infectious diseases such as during outbreaks or in patient care. This study aimed to produce an ELISA-based diagnostic with an increased sensitivity of detection compared to the standard 96-well method in the immunologic diagnosis of infectious diseases. A '3DStack' was developed using readily available, low cost fabrication technologies namely nanoimprinting and press stamping with an increased surface area of 4 to 6 times more compared to 96-well plates. This was achieved by stacking multiple nanoimprinted polymer sheets. The flow of analytes between the sheets was enhanced by rotating the 3DStack and confirmed by Finite-Element (FE) simulation. An Immunoglobulin G (IgG) ELISA for the detection of antibodies in human serum raised against Rubella virus was performed for validation. An improved sensitivity of up to 1.9 folds higher was observed using the 3DStack compared to the standard method. The increased surface area of the 3DStack developed using nanoimprinting and press stamping technologies, and the flow pattern between sheets generated by rotating the 3DStack were potential contributors to a more sensitive ELISA-based diagnostic device.

  9. DEPIVIH 2: Use of three HIV testing methods in French primary care settings - ELISA laboratory screening versus two rapid point-of-care HIV tests.

    Science.gov (United States)

    Papadima, D; Gauthier, R; Prévoteau du Clary, F; Bouée, S; Conort, G; Livrozet, J-M; Taulera, O; Wajsbrot, A; Majerholc, C; Peter, J-M; Aubert, J-P

    2018-03-01

    The primary endpoint was to evaluate the use of HIV testing methods by French primary care providers: Elisa laboratory screening, instant result HIV diagnostic test and rapid result HIV diagnostic test. The secondary endpoints were the population screening rate of unknown HIV status consulting during the study period, reasons for screening and for choosing the specific screening method, the investigators' satisfaction with the rapid diagnostic test (RDT) and problems encountered. National prospective interventional study with French family physicians (FP) from December 2013 to December 2014. FPs enrolled all consenting adults consulting for an HIV screening test during a 6-month period: the choice was an Elisa laboratory test or one of the two RDTs. During the study period, 43 FPs included 981 patients. HIV screening was performed for the first time for 31.6% of patients; 767 (78.2%) Elisa laboratory test prescriptions and 214 (21.8%) RDTs were performed, leading to a screening rate of 1.3%. For 120 (15.7%) of the Elisa laboratory tests, the result was not reported and six RDTs were not valid. Nine patients were diagnosed as HIV-infected (0.9%): five with Elisa laboratory test and four with RDT. Almost 90% of FPs were willing to keep on using RDTs in their daily practice. In general practice, RDTs may be an important additional tool to traditional HIV screening. They could account for one in five tests prescribed in this context. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. Occurrence of Foodborne Pathogens in Chickens Sandwiches Distributed in Different Supermarkets of Tehran Province, Iran

    Directory of Open Access Journals (Sweden)

    Zohreh Mashak

    2014-07-01

    Full Text Available Background: Increasing urbanization, immigration and tourism has changed the human lifestyle. This modern lifestyle has demanded safety, quality, and fast availability of ready to eat (RTE foods like chicken sandwiches. Objectives: For presentation of proper solutions regarding food safety, identification of pathogens in different foods is necessary. Therefore, the present study was carried out to assess the microbiological quality of chicken sandwiches distributed in Tehran province, Iran. Materials and Methods: A total of 200 chicken sandwich samples (chicken sausage, chicken fillet, minced chicken fillet were purchased from different supermarkets in Tehran city randomly during 2013 and transported to the laboratory of food hygiene of Islamic Azad University, Karaj branch under temperature-controlled conditions for bacteriological examination by American Public Health Association (APHA method. Results: The average count ± standard error (and percent of unacceptable samples of S. aureus, B. cereus and Coliform were 1.6 ± 0.56 (28%, 2.0 ± 0.62 (10%, 4.2 ± 1.12 (50% CFU/g, respectively. Moreover, E. coli and Salmonella spp. were identified in 21% of chicken sandwich samples. Conclusions: The large number of foodborne pathogens detected in this study, represented a potential health hazard to consumers. Thus, it is necessary to employ Good Hygiene Practices (GHP and Hazard Analysis and Critical Control Points (HACCP in order to minimize the risk caused by secondary contamination.

  11. Detection of Plasmodium Aldolase Using a Smartphone and Microfluidic Enzyme Linked Immunosorbent Assay

    Directory of Open Access Journals (Sweden)

    Nikhil S. Gopal

    2017-01-01

    Full Text Available Background. Malaria control efforts are limited in rural areas. A low-cost system to monitor response without the use of electricity is needed. Plasmodium aldolase is a malaria biomarker measured using enzyme linked immunosorbent assay (ELISA techniques. A three-part system using ELISA was developed consisting of a microfluidic chip, hand crank centrifuge, and a smartphone. Methods. A circular microfluidic chip was fabricated using clear acrylic and a CO2 laser. A series of passive valves released reagents at precise times based upon centrifugal force. Color change was measured via smartphone camera using an application programmed in Java. The microchip was compared to a standard 96-well sandwich ELISA. Results. Results from standard ELISA were compared to microchip at varying concentrations (1–10 ng/mL. Over 15 different microfluidic patterns were tested, and a final prototype of the chip was created. The prototype microchip was compared to standard sandwich ELISA (n=20 using samples of recombinant aldolase. Color readings of standard ELISA and microfluidic microchip showed similar results. Conclusion. A low-cost microfluidic system could detect and follow therapeutic outcomes in rural areas and identify resistant strains.

  12. Analysis of syntactic foam – GFRP sandwich composites for flexural loads

    Science.gov (United States)

    Paul, Daniel; Velmurugan, R.; Jayaganthan, R.; Gupta, N. K.; Manzhirov, A. V.

    2018-04-01

    The use of glass microballoon (GMB) — epoxy syntactic foams as a sandwich core material is studied. The skins and foam core are fabricated and joined instantaneously unlike the procedures followed in the previous studies. Each successive layer of the sandwich is fabricated when the previous layer is in a semi-gelled state. These sandwich samples are characterized for their properties under flexural loading. The failure modes and mechanical properties are carefully investigated. The change in fabrication technique results in a significant increase in the load bearing pattern of the sandwich. In earlier studies, debonding was found to occur prematurely since the bonding between the skins and core is the weakest plane. Using the current technique, core cracking occurs first, followed by skin fiber breaking and debonding happens at the end. This ensures that the load carrying phase of the structure is extended considerably. The sandwich is also analytically studied using Reddy’s higher order shear deformation theory. A higher order theory is selected as the sandwich can no longer be considered as a thin beam and thus shear effects also need to be considered in addition to bending effects.

  13. Finite element formulation of viscoelastic sandwich beams using fractional derivative operators

    Science.gov (United States)

    Galucio, A. C.; Deü, J.-F.; Ohayon, R.

    This paper presents a finite element formulation for transient dynamic analysis of sandwich beams with embedded viscoelastic material using fractional derivative constitutive equations. The sandwich configuration is composed of a viscoelastic core (based on Timoshenko theory) sandwiched between elastic faces (based on Euler-Bernoulli assumptions). The viscoelastic model used to describe the behavior of the core is a four-parameter fractional derivative model. Concerning the parameter identification, a strategy to estimate the fractional order of the time derivative and the relaxation time is outlined. Curve-fitting aspects are focused, showing a good agreement with experimental data. In order to implement the viscoelastic model into the finite element formulation, the Grünwald definition of the fractional operator is employed. To solve the equation of motion, a direct time integration method based on the implicit Newmark scheme is used. One of the particularities of the proposed algorithm lies in the storage of displacement history only, reducing considerably the numerical efforts related to the non-locality of fractional operators. After validations, numerical applications are presented in order to analyze truncation effects (fading memory phenomena) and solution convergence aspects.

  14. A comparison of ELISA methods for the determination of human serum antibodies to Haemophilus influenzae type b

    NARCIS (Netherlands)

    van Gageldonk PGM; Mariani M; Berbers GAM; LVO-BI; Centro Ricerche; CHIRON S.p.A.; Siena; Italy/Laboratorio di Immunochimica e Sierologia Sperimentale/Departimento Immunologia

    1998-01-01

    Een vergelijking tussen de non-competitieve ELISA van Phipps et al., de klassieke radio-antigeen bindings assay (RABA) en de nieuw ontwikkelde Chiron competitieve ELISA voor de bepaling van anti-Hib polysaccharide (HibPs) antistof concentraties in humane sera wordt beschreven in het rapport. Voor

  15. A J Integral Approach for Measuring Cohesive Laws Using a Modified DCB Sandwich Specimen

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Berggreen, Christian; Sørensen, Bent F.

    2007-01-01

    mode mixities. The sandwich specimen consists of glass fiber faces and Divinycell H200 foam core. Arbitrary stiffening of the sandwich specimen with steel bars adhered to the faces reduces rotations and ensures that the method is useable for a wide range of materials. The J integral is employed...... and the opening of the pre-crack tip is recorded by a commercial digital photogrammetry measurement system. Cohesive laws are extracted by differentiating J with respect to the normal and tangential opening of the pre-crack tip. Some results are presented and discussed....

  16. Active structural health monitoring of composite plates and sandwiches

    Directory of Open Access Journals (Sweden)

    Sadílek P.

    2013-12-01

    Full Text Available The aim of presented work is to design, assemble and test a functional system, that is able to reveal damage from impact loading. This is done by monitoring of change of spectral characteristics on a damaged structure that is caused by change of mechanical properties of material or by change of structure’s geometry. Excitation and monitoring of structures was done using piezoelectric patches. Unidirectional composite plate was tested for eigenfrequencies using chirp signal. The eigenfrequencies were compared to results from experiments with an impact hammer and consequently with results from finite element method. Same method of finding eigenfrequencies was used on a different unidirectional composite specimen. Series of impacts were performed. Spectrum of eigenfrequencies was measured on undamaged plate and then after each impact. Measurements of the plate with different level of damage were compared. Following experiments were performed on sandwich materials where more different failures may happen. Set of sandwich beams (cut out from one plate made of two outer composite layers and a foam core was investigated and subjected to several impacts. Several samples were impacted in the same manner to get comparable results. The impacts were performed with growing impact energy.

  17. Biotin/avidin sandwich enzyme-linked immunosorbent assay for Culicidae mosquito blood meal identification

    Directory of Open Access Journals (Sweden)

    A. M. Marassá

    2008-01-01

    Full Text Available The knowledge of mosquitoes Culicidae host feeding patterns is basic to understand the roles of different species and to indicate their importance in the epidemiology of arthropod-borne diseases. A laboratory assay was developed aiming at standardizing the biotin-avidin sandwich enzyme-linked immunosorbent assay, which was unprecedented for mosquito blood meal identification. The enzyme-linked immunosorbent assay (ELISA activity was evaluated by the detection of titers on each sample of the 28 blood-fed Culex quinquefasciatus. In light of the high sensitivity that the technique permits, by means of small quantities of specific antibodies commercially provided and phosphatase substrate which reinforces additional dilutions, human and rat blood meals were readily identified in all laboratory-raised Culex quinquefasciatus tested. The assay was effective to detect human blood meal dilutions up to 1:4,096, which enables the technique to be applied in field studies. Additionally, the present results indicate a significant difference between the detection patterns recorded from human blood meal which corroborate the results of host feeding patterns.

  18. Probabilistic fatigue life of balsa cored sandwich composites subjected to transverse shear

    DEFF Research Database (Denmark)

    Dimitrov, Nikolay Krasimirov; Berggreen, Christian

    2015-01-01

    A probabilistic fatigue life model for end-grain balsa cored sandwich composites subjectedto transverse shear is proposed. The model is calibrated to measured three-pointbending constant-amplitude fatigue test data using the maximum likelihood method. Some possible applications of the probabilistic...

  19. Ultra-tiny ZnMn2O4 nanoparticles encapsulated in sandwich-like carbon nanosheets for high-performance supercapacitors

    Science.gov (United States)

    Guan, Yongxin; Feng, Yangyang; Mu, Yanping; Fang, Ling; Zhang, Huijuan; Wang, Yu

    2016-11-01

    Known as an excellent energy storage material, ZnMn2O4 has a wide range of applications in supercapacitors. In this report, a special sandwich-like structure of ZnMn2O4/C has been first designed and synthesized via a simple hydrothermal method and subsequent calcinations. The designed special sandwich-like structure can benefit ion exchange and remit the probable volume changes during a mass of electrochemical reactions. Furthermore, the porous carbon nanosheets, derived from low-cost glucose, can effectively increase ion flux. Therefore, the novel sandwich-like ZnMn2O4 nanoparticles encapsulated in carbon nanosheets can undoubtedly demonstrate an exceptional electrochemical performance for SCs. In this work, the composite material with porous sandwich-like structure exhibits excellent cyclic stability for 5000 cycles (˜5% loss) and high specific capacitance of 1786 F g-1.

  20. Advantages of bioconjugated silica-coated nanoparticles as an innovative diagnosis for human toxoplasmosis.

    Science.gov (United States)

    Aly, Ibrahim; Taher, Eman E; El Nain, Gehan; El Sayed, Hoda; Mohammed, Faten A; Hamad, Rabab S; Bayoumy, Elsayed M

    2018-01-01

    Nanotechnology is a promising arena for generating new applications in Medicine. To successfully functionalised nanoparticles for a given biomedical application, a wide range of chemical, physical and biological factors have to be taken into account. Silica-coated nanoparticles, (SiO2NP) exhibit substantial diagnostic activity owing to their large surface to volume ratios and crystallographic surface structure. This work aimed to evaluate the advantage of bioconjugation of SiO2NP with PAb against Toxoplasma lyzate antigen (TLA) as an innovative diagnostic method for human toxoplasmosis. This cross-sectional study included 120 individuals, divided into Group I: 70 patients suspected for Toxoplasma gondii based on the presence of clinical manifestation. Group II: 30 patients harboring other parasites than T. gondii Group III: 20 apparently healthy individuals free from toxoplasmosis and other parasitic infections served as negative control. Detection of circulating Toxoplasma antigen was performed by Sandwich ELISA and Nano-sandwich ELISA on sera and pooled urine of human samples. Using Sandwich ELISA, 10 out of 70 suspected Toxoplasma-infected human serum samples showed false negative and 8 out of 30 of other parasites groups were false positive giving 85.7% sensitivity and 84.0% specificity, while the sensitivity and specificity were 78.6% and 70% respectively in urine samples. Using Nano-Sandwich ELISA, 7 out of 70 suspected Toxoplasma-infected human samples showed false negative results and the sensitivity of the assay was 90.0%, while 4 out of 30 of other parasites groups were false positive giving 92.0% specificity, while the sensitivity and specificity were 82.6% and 80% respectively in urine samples. In conclusion, our data demonstrated that loading SiO2 nanoparticles with pAb increased the sensitivity and specificity of Nano-sandwich ELISA for detection of T.gondii antigens in serum and urine samples, thus active (early) and light infections could be easily

  1. Detection of Fusarium verticillioides by PCR-ELISA based on FUM21 gene.

    Science.gov (United States)

    Omori, Aline Myuki; Ono, Elisabete Yurie Sataque; Bordini, Jaqueline Gozzi; Hirozawa, Melissa Tiemi; Fungaro, Maria Helena Pelegrinelli; Ono, Mario Augusto

    2018-08-01

    Fusarium verticillioides is a primary corn pathogen and fumonisin producer which is associated with toxic effects in humans and animals. The traditional methods for detection of fungal contamination based on morphological characteristics are time-consuming and show low sensitivity and specificity. Therefore, the objective of this study was to develop a PCR-ELISA based on the FUM21 gene for F. verticillioides detection. The DNA of the F. verticillioides, Fusarium sp., Aspergillus sp. and Penicillium sp. isolates was analyzed by conventional PCR and PCR-ELISA to determine the specificity. The PCR-ELISA was specific to F. verticillioides isolates, showed a 2.5 pg detection limit and was 100-fold more sensitive than conventional PCR. In corn samples inoculated with F. verticillioides conidia, the detection limit of the PCR-ELISA was 1 × 10 4 conidia/g and was also 100-fold more sensitive than conventional PCR. Naturally contaminated corn samples were analyzed by PCR-ELISA based on the FUM21 gene and PCR-ELISA absorbance values correlated positively (p PCR-ELISA developed in this study can be useful for F. verticillioides detection in corn samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Diagnostic potential of Fasciola gigantica-derived 14.5 kDa fatty acid binding protein in the immunodiagnosis of bubaline fascioliasis.

    Science.gov (United States)

    Allam, G; Bauomy, I R; Hemyeda, Z M; Diab, T M; Sakran, T F

    2013-06-01

    The 14.5 kDa fatty acid binding protein (FABP) was isolated from the crude extract of adult Fasciola gigantica worms. Polyclonal anti-FABP IgG was generated in rabbits immunized with prepared FABP antigen. Sandwich enzyme-linked immunosorbent assay (ELISA) was applied to detect coproantigen in stools and circulating Fasciola antigen (CA) in sera of 126 water buffaloes by using purified and horseradish peroxidase (HRP)-conjugated anti-FABP IgG. Sandwich ELISA sensitivity was 96.97% and 94.95%; while specificity was 94.12% and 82.35% for coproantigen and CA detection, respectively. However, sensitivity and specificity of the Kato-Katz technique was 73.74% and 100%, respectively. The diagnostic efficacy of sandwich ELISA was 96.55% and 93.1% for coproantigen and CA detection, respectively. In contrast, the diagnostic efficacy of the Kato-Katz technique was 77.59%. In conclusion, these results demonstrate that the purified 14.5 kDa FABP provides a more suitable antigen for immunodiagnosis of early and current bubaline fascioliasis by using sandwich ELISA.

  3. A sensitive enzyme-linked immunosorbent assay for the determination of fish protein in processed foods.

    Science.gov (United States)

    Shibahara, Yusuke; Uesaka, Yoshihiko; Wang, Jun; Yamada, Shoichi; Shiomi, Kazuo

    2013-01-15

    Fish is one of the most common causes of food allergy and its major allergen is parvalbumin, a 12 kDa muscular protein. In this study, a sandwich enzyme-linked immunosorbent assay (ELISA) for the determination of fish protein in processed foods was developed using a polyclonal antibody raised against Pacific mackerel parvalbumin. The developed sandwich ELISA showed 22.6-99.0% reactivity (based on the reactivity to Pacific mackerel parvalbumin) to parvalbumins from various species of fish. The limits of detection and quantitation were estimated to be 0.23 and 0.70 μg protein per g of food, respectively. When the sandwich ELISA was subjected to inter-laboratory validation, spiked fish protein was recovered from five model processed foods in the range of 69.4-84.8% and the repeatability and reproducibility relative standard deviations were satisfactorily low (≤ 10.5%). Thus, the sandwich ELISA was judged to be a useful tool to determine fish protein in processed foods. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Salads, Sandwiches and Desserts.

    Science.gov (United States)

    Marine Corps Inst., Washington, DC.

    Developed as part of the Marine Corps Institute (MCI) correspondence training program, this course on salads, sandwiches, and desserts is designed to provide Marine food service personnel with a general background in the proper techniques for the preparation of these items. Introductory materials include specific information for MCI students and a…

  5. 3D Energy Absorption Diagram Construction of Paper Honeycomb Sandwich Panel

    Directory of Open Access Journals (Sweden)

    Dongmei Wang

    2018-01-01

    Full Text Available Paper honeycomb sandwich panel is an environment-sensitive material. Its cushioning property is closely related to its structural factors, the temperature and humidity, random shocks, and vibration events in the logistics environment. In order to visually characterize the cushioning property of paper honeycomb sandwich panel in different logistics conditions, the energy absorption equation of per unit volume of paper honeycomb sandwich panel was constructed by piecewise function. The three-dimensional (3D energy absorption diagram of paper honeycomb sandwich panel was constructed by connecting the inflexion of energy absorption curve. It takes into account the temperature, humidity, strain rate, and characteristics of the honeycomb structure. On the one hand, this diagram breaks through the limitation of the static compression curve of paper honeycomb sandwich panel, which depends on the test specimen and is applicable only to the standard condition. On the other hand, it breaks through the limitation of the conventional 2D energy absorption diagram which has less information. Elastic modulus was used to normalize the plateau stress and energy absorption per unit volume. This makes the 3D energy absorption diagram universal for different material sandwich panels. It provides a new theoretical basis for packaging optimized design.

  6. Finite element simulation of low velocity impact loading on a sandwich composite

    Directory of Open Access Journals (Sweden)

    Vishwas M.

    2018-01-01

    Full Text Available Sandwich structure offer more advantage in bringing flexural stiffness and energy absorption capabilities in the application of automobile and aerospace components. This paper presents comparison study and analysis of two types of composite sandwich structures, one having Jute Epoxy skins with rubber core and the other having Glass Epoxy skins with rubber core subjected to low velocity normal impact loading. The behaviour of sandwich structure with various parameters such as energy absorption, peak load developed, deformation and von Mises stress and strain, are analyzed using commercially available analysis software. The results confirm that sandwich composite with jute epoxy skin absorbs approximately 20% more energy than glass epoxy skin. The contact force developed in jute epoxy skin is approximately 2.3 times less when compared to glass epoxy skin. von Mises stress developed is less in case of jute epoxy. The sandwich with jute epoxy skin deforms approximately 1.6 times more than that of same geometry of sandwich with glass epoxy skin. Thus exhibiting its elastic nature and making it potential candidate for low velocity impact application.

  7. Preparation and Characteristic of Dextran-BSA Antibody and Establishment of its ELISA Immunoassay.

    Science.gov (United States)

    Xie, Zhen-ming; Yu, Lin; Fang, Li-sha

    2015-01-01

    The enzyme-linked immunosorbent assay (ELISA) is a potential tool for the determination of dextran. In this study, dextran neoglycoprotein antigens were prepared by Reductive Amination method, and were confirmed by SDS-PAGE and free amino detection. The impact factors such as different oxidation degree of dextran, the conjugate reaction time to BSA were investigated. The best preparation conditions were obtained (n(dextran)/n(oxidant) of NaIO4 = 1/120, the reaction time of 24 h), and the antigen with best combination with standard was obtained. The antigens interacted with standard antibody and were evaluated through ELISA. The immunogen was immunized with white rabbits to obtained antibody, respectively. A general and broad class-specific ELISA immunoassay was developed for dextran detection according to ELISA theory. The optimized conditions of assay used coating antigen at 10 μg/mL, reaction time of antibody and rabbit-anti-bovine IgG in 45 min, blocking reagents with 5% calf serum. The developed ELISA detection method with good linear and accuracy was put to use for quantitative analysis of dextran T40 in commercial sugarpractical for detection of dextran.

  8. Investigation of enrofloxacin residues in broiler tissues using ELISA and LC-MS/MS.

    Science.gov (United States)

    Panzenhagen, Pedro Henrique N; Aguiar, Waldemir S; Gouvêa, Raquel; de Oliveira, Andréa M G; Barreto, Fabiano; Pereira, Virgínia L A; Aquino, Maria Helena C

    2016-01-01

    This study investigated the efficiency of an enrofloxacin ELISA test kit to detect the presence of enrofloxacin residues in broiler tissues compared with LC-MS/MS. Broiler tissues from 72 samples consisting of 60 breast muscle, six pools of livers (500 g each) and six pools of kidneys (500 g each) were obtained from six different slaughterhouses. Breast muscle from 10 carcasses and pools of livers and kidneys from approximately 200 carcasses of the same flock were collected from each slaughterhouse. ELISA and HPLC were used to identify and quantify the contamination of the samples with enrofloxacin. A total of 72% of the analysed samples contained enrofloxacin residues detected by the ELISA and 22.2% were detected by LC-MS/MS. The mean values of enrofloxacin contamination found in chicken breast by ELISA and HPLC were 8.63 and 12.25 μg kg(-1), respectively. None of the samples exceeded the maximum limit of 100 μg kg(-1) by both methods set by the European Union as well as the Brazilian Agriculture Ministry. All positive samples for enrofloxacin residues detected by LC-MS/MS were also positive by ELISA. These data confirm the efficiency of the ELISA test, and suggest its use as a screening method for enrofloxacin residues in poultry tissues due to its quick results, low price and ease of applicability.

  9. His-tag ELISA for the detection of humoral tumor-specific immunity

    Directory of Open Access Journals (Sweden)

    Disis Mary L

    2008-05-01

    Full Text Available Abstract Background The application of high throughput molecular techniques such as SEREX are resulting in the identification of a multitude of tumor associated antigens. As newly identified antigens are incorporated into a variety of clinical trials, standardization of immunologic monitoring methods becomes increasingly important. We questioned whether mammalian cell expression of a histadine-linked human protein could be used to produce antigen suitable for detecting tumor-specific humoral immunity and whether such an assay could be amenable to standardization for clinical use. Methods We designed a his-tagged capture ELISA based on lysate from genetically engineered CHO cells for detection of antibodies to insulin-like growth factor binding protein 2, a novel tumor antigen. We performed technical and preliminary clinical validation studies, including comparison to a standard indirect ELISA based on commercially prepared recombinant antigen. Results The his-tagged capture ELISA could be standardized. Precision experiments resulted in CVs 2 values of 0.99. In comparison to Western blot analysis, his-tag and indirect ELISA accurately identified 88% and 93% of samples, respectively. Sample concordance between capture and indirect assays was highly significant (p = 0.003. Furthermore, significantly greater levels of IGFBP-2 antibody immunity were found in cancer patients compared to normal controls (p = 0.008. Conclusion A genetically engineered cell lysate based ELISA can be amenable to standardization and can detect increased levels of antibody immunity to tumor-associated antigen in cancer patients compared to non tumor-bearing healthy controls.

  10. Canine specific ELISA for coagulation factor VII

    DEFF Research Database (Denmark)

    Knudsen, Tom; Kjelgaard-Hansen, Mads; Tranholm, Mikael

    2011-01-01

    available to date. In this study, a canine specific ELISA for measurement of FVII:Ag in plasma was developed and validated. The FVII:Ag ELISA correctly diagnosed homozygous and heterozygous hereditary FVII deficiency. Together with activity based assays, such as FVII:C, the FVII:Ag ELISA should be valuable...

  11. Impact damage in aircraft composite sandwich panels

    Science.gov (United States)

    Mordasky, Matthew D.

    An experimental study was conducted to develop an improved understanding of the damage caused by runway debris and environmental threats on aircraft structures. The velocities of impacts for stationary aircraft and aircraft under landing and takeoff speeds was investigated. The impact damage by concrete, asphalt, aluminum, hail and rubber sphere projectiles was explored in detail. Additionally, a kinetic energy and momentum experimental study was performed to look at the nature of the impacts in more detail. A method for recording the contact force history of the impact by an instrumented projectile was developed and tested. The sandwich composite investigated was an IM7-8552 unidirectional prepreg adhered to a NOMEXRTM core with an FM300K film adhesive. Impact experiments were conducted with a gas gun built in-house specifically for delivering projectiles to a sandwich composite target in this specic velocity regime (10--140 m/s). The effect on the impact damage by the projectile was investigated by ultrasonic C-scan, high speed camera and scanning electron and optical microscopy. Ultrasonic C-scans revealed the full extent of damage caused by each projectile, while the high speed camera enabled precise projectile velocity measurements that were used for striking velocity, kinetic energy and momentum analyses. Scanning electron and optical images revealed specific features of the panel failure and manufacturing artifacts within the lamina and honeycomb core. The damage of the panels by different projectiles was found to have a similar damage area for equivalent energy levels, except for rubber which had a damage area that increased greatly with striking velocity. Further investigation was taken by kinetic energy and momentum based comparisons of 19 mm diameter stainless steel sphere projectiles in order to examine the dominating damage mechanisms. The sandwich targets were struck by acrylic, aluminum, alumina, stainless steel and tungsten carbide spheres of the

  12. Investigation on Wall Panel Sandwiched With Lightweight Concrete

    Science.gov (United States)

    Lakshmikandhan, K. N.; Harshavardhan, B. S.; Prabakar, J.; Saibabu, S.

    2017-08-01

    The rapid population growth and urbanization have made a massive demand for the shelter and construction materials. Masonry walls are the major component in the housing sector and it has brittle characteristics and exhibit poor performance against the uncertain loads. Further, the structure requires heavier sections for carrying the dead weight of masonry walls. The present investigations are carried out to develop a simple, lightweight and cost effective technology for replacing the existing wall systems. The lightweight concrete is developed for the construction of sandwich wall panel. The EPS (Expanded Polystyrene) beads of 3 mm diameter size are mixed with concrete and developed a lightweight concrete with a density 9 kN/m3. The lightweight sandwich panel is cast with a lightweight concrete inner core and ferrocement outer skins. This lightweight wall panel is tested for in-plane compression loading. A nonlinear finite element analysis with damaged plasticity model is carried out with both material and geometrical nonlinearities. The experimental and analytical results were compared. The finite element study predicted the ultimate load carrying capacity of the sandwich panel with reasonable accuracy. The present study showed that the lightweight concrete is well suitable for the lightweight sandwich wall panels.

  13. Label-free super sandwich electrogenerated chemiluminescence biosensor for the determination of the HIV gene

    International Nuclear Information System (INIS)

    Ruan, Sanpeng; Li, Zhejian; Qi, Honglan; Gao, Qiang; Zhang, Chengxiao

    2014-01-01

    We describe a highly sensitive electrochemiluminescence (ECL) based method for the determination of the human immunodeficiency virus-1 (HIV-1) gene. A long-range self-assembled double strand DNA (ds-DNA) is used as a carrier, and the ruthenium complex Ru(phen) 3 2+ as an ECL indicator for signal amplification. The thiolated ss-DNA serving as a capture probe is firstly self-assembled on the surface of a gold electrode. After the target HIV-1 gene is completely hybridized with the capture probe, two previously hybridized auxiliary probes are hybridized with the target HIV-1 gene to form long-range super sandwich ds-DNA polymers on the surface of the electrode. Finally, the ECL indicator is intercalated into the super sandwich ds-DNA grooves. This results in a strongly increased ECL in tripropylamine solution because a large fraction of the intercalator is intercalated into super sandwich ds-DNA. The results showed that the increased ECL intensity is directly related to the logarithm of the concentration of the HIV-1 gene in the range from 0.1 pM to 0.1 nM, with a detection limit of 0.022 pM and using only 10 μL of analyte samples. The method can effectively discriminate target HIV-1 gene (a perfectly matched ss-DNA) from a 2-base mismatched ss-DNA. This work demonstrates that the high sensitivity and selectivity of an ECL DNA biosensor can be largely improved by using super sandwich ds-DNA along with ECL indicators. (author)

  14. Design Analysis of the Mixed Mode Bending Sandwich Specimen

    DEFF Research Database (Denmark)

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, Leif A.

    2010-01-01

    A design analysis of the mixed mode bending (MMB) sandwich specimen for face–core interface fracture characterization is presented. An analysis of the competing failure modes in the foam cored sandwich specimens is performed in order to achieve face–core debond fracture prior to other failure modes...... for the chosen geometries and mixed mode loading conditions....

  15. Titration ELISA as a Method to Determine the Dissociation Constant of Receptor Ligand Interaction.

    Science.gov (United States)

    Eble, Johannes A

    2018-02-15

    The dissociation constant describes the interaction between two partners in the binding equilibrium and is a measure of their affinity. It is a crucial parameter to compare different ligands, e.g., competitive inhibitors, protein isoforms and mutants, for their binding strength to a binding partner. Dissociation constants are determined by plotting concentrations of bound versus free ligand as binding curves. In contrast, titration curves, in which a signal that is proportional to the concentration of bound ligand is plotted against the total concentration of added ligand, are much easier to record. The signal can be detected spectroscopically and by enzyme-linked immunosorbent assay (ELISA). This is exemplified in a protocol for a titration ELISA that measures the binding of the snake venom-derived rhodocetin to its immobilized target domain of α2β1 integrin. Titration ELISAs are versatile and widely used. Any pair of interacting proteins can be used as immobilized receptor and soluble ligand, provided that both proteins are pure, and their concentrations are known. The difficulty so far has been to determine the dissociation constant from a titration curve. In this study, a mathematical function underlying titration curves is introduced. Without any error-prone graphical estimation of a saturation yield, this algorithm allows processing of the raw data (signal intensities at different concentrations of added ligand) directly by mathematical evaluation via non-linear regression. Thus, several titration curves can be recorded simultaneously and transformed into a set of characteristic parameters, among them the dissociation constant and the concentration of binding-active receptor, and they can be evaluated statistically. When combined with this algorithm, titration ELISAs gain the advantage of directly presenting the dissociation constant. Therefore, they may be used more efficiently in the future.

  16. Two dimensional dynamic analysis of sandwich plates with gradient foam cores

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Lin; Xiao, Deng Bao; Zhao, Guiping [State Key Laboratory for Mechanical structure Strength and Vibration, School of AerospaceXi' an Jiaotong University, Xi' an (China); Cho, Chong Du [Dept. of Mechanical Engineering, Inha University, Inchon (Korea, Republic of)

    2016-09-15

    Present investigation is concerned about dynamic response of composite sandwich plates with the functionally gradient foam cores under time-dependent impulse. The analysis is based on a model of the gradient sandwich plate, in which the face sheets and the core adopt the Kirchhoff theory and a [2, 1]-order theory, respectively. The material properties of the gradient foam core vary continuously along the thickness direction. The gradient plate model is validated with the finite element code ABAQUS®. And the results show that the proposed model can predict well the free vibration of composite sandwich plates with gradient foam cores. The influences of gradient foam cores on the natural frequency, deflection and energy absorbing of the sandwich plates are also investigated.

  17. Face/core debond fatigue crack growth characterization using the sandwich mixed mode bending specimen

    DEFF Research Database (Denmark)

    Manca, Marcello; Quispitupa, Amilcar; Berggreen, Christian

    2012-01-01

    Face/core fatigue crack growth in foam-cored sandwich composites is examined using the mixed mode bending (MMB) test method. The mixed mode loading at the debond crack tip is controlled by changing the load application point in the MMB test fixture. Sandwich specimens were manufactured using H45...... and H100 PVC foam cores and E-glass/polyester face sheets. All specimens were pre-cracked in order to define a sharp crack front. The static debond fracture toughness for each material configuration was measured at different mode-mixity phase angles. Fatigue tests were performed at 80% of the static...

  18. Magnetic properties of sandwiches based on Nd-Co and Y-Co amorphous alloys

    International Nuclear Information System (INIS)

    Ndjaka, J.M.B.; Givord, D.

    1996-01-01

    Y-Co/Nd-Co/Y-Co and Nd-Co/Y-Co/Nd-Co amorphous sandwiches have been prepared by d.c. triode sputtering. The chemical composition of the constituent layers is R 0.33 Co 0.67 (R=Y, Nd). In such systems, the Co moments are coupled parallel through the whole sandwich thickness by strong positive 3d-3d exchange interactions. But, the coercive fields of the constituent layers taken separately differ. In the sandwiches as well, the reversal of magnetization in the different layers occurs at different values of the applied magnetic field. This phenomenon has been analysed qualitatively in terms of creation and annihilation of walls at the interfaces between layers for sandwiches where the thicknesses of the constituent layers are about 1000 A. In sandwiches where the thickness of the constituent layers is 100 A, the wall width available is very weak and the value of the applied magnetic field necessary for the creation of such a wall is higher than the coercive field of the entire sandwich system. As a result, the magnetization of the sandwich system reverses as a whole like in homogeneous systems. (orig.)

  19. Sandwich design for ships and railway wagons

    Energy Technology Data Exchange (ETDEWEB)

    Olsson, K.-A. [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Aeronautics

    2000-07-01

    In Sweden we have long experience of different types of vehicles and ships in sandwich construction, especially for Navy ships, such as minesweepers, mine-counter-measure-vessels and corvettes. As face materials mostly GRP and FRP have been used, but also metallic materials of Al-alloys, coated carbon steel and stainless steel. Core materials have usually been cellular plastic foams of cross-linked PVC, but also extruded PS, PUR, PEI and PMI. A lot of different continuous and discontinuous manufacturing processes are used. Vacuum assisted infusion is used in the last years, because it is a closed process, gives high fibre content and a good quality of the laminates. Sandwich design has mainly been used in the transportation area, where lightweight design is needed to give higher performance and load bearing capacity. The use of sandwich will give high stiffness- and strength-to weight ratio. These are in most cases not enough from economic point of view, but even other integrated functions must be considered, i.e. insulation, energy consumption, damping, less components, lower manufacturing costs, low maintenance, signature effects (military) etc. (orig.)

  20. Study on the sandwich piezoelectric ceramic ultrasonic transducer in thickness vibration

    International Nuclear Information System (INIS)

    Lin Shuyu; Tian Hua

    2008-01-01

    A sandwich piezoelectric ceramic ultrasonic transducer in thickness vibration is studied. The transducer consists of front and back metal masses, and coaxially segmented, thickness polarized piezoelectric ceramic thin rings. For this kind of sandwich piezoelectric transducers in thickness vibration, it is required that the lateral dimension of the transducer is sufficiently large compared with its longitudinal dimension so that no lateral displacements in the transducer can occur (laterally clamped). In this paper, the thickness vibration of the piezoelectric ceramic stack consisting of a number of identical piezoelectric ceramic thin rings is analysed and its electro-mechanical equivalent circuit is obtained. The resonance frequency equation for the sandwich piezoelectric ceramic ultrasonic transducer in thickness vibration is derived. Based on the frequency equation, two sandwich piezoelectric ceramic ultrasonic transducers are designed and manufactured, and their resonance frequencies are measured. It is shown that the measured resonance frequencies are in good agreement with the theoretical results. This kind of sandwich piezoelectric ultrasonic transducer is expected to be used in megasonic ultrasonic cleaning and sonochemistry where high power and high frequency ultrasound is needed

  1. Detection of Trypanosoma congolense type savannah in field samples of buffy coats of bovins using PCR-ELISA

    International Nuclear Information System (INIS)

    Sidibe, I.

    2007-01-01

    PCR-ELISA was set up to detect strain of Trypanosoma congolense type savannah in field samples of buffy coats. Results of PCR-ELISA and PCR were compared and the sensibility and specificity of both techniques were also compared with those of the method of Murray [1] for the detection of TCS in 257 samples. The PCR products were labelling with DIG-dUTP during amplification cycles of the repetitive satellite DNA. A DNA biotinyled capture probe was used to detect the amplicon by ELISA in streptavidine coated microplates. Both of PCR-ELISA and PCR were more sensible and more specific than the method of Murray. Indeed, for the 257 samples analysed by the three techniques, PCR-ELISA and PCR have detected TCS in 98 and 97 samples respectively, whereas the method of Murray has detected TCS in only 39 samples. In addition, PCRELISA and PCR had almost the same sensibility and specificity. So, PCR-ELISA and PCR have respectively detected TCS in 38.62% and 39.22% of all the 334 samples analysed by both techniques during this study. At the end of this study, the cost of analyse by PCR-ELISA of a sample of buffy coat, was evaluated at 1993 FCFA or Euro 3,04. (author) [fr

  2. Insert Design and Manufacturing for Foam-Core Composite Sandwich Structures

    Science.gov (United States)

    Lares, Alan

    Sandwich structures have been used in the aerospace industry for many years. The high strength to weight ratios that are possible with sandwich constructions makes them desirable for airframe applications. While sandwich structures are effective at handling distributed loads such as aerodynamic forces, they are prone to damage from concentrated loads at joints or due to impact. This is due to the relatively thin face-sheets and soft core materials typically found in sandwich structures. Carleton University's Uninhabited Aerial Vehicle (UAV) Project Team has designed and manufactured a UAV (GeoSury II Prototype) which features an all composite sandwich structure fuselage structure. The purpose of the aircraft is to conduct geomagnetic surveys. The GeoSury II Prototype serves as the test bed for many areas of research in advancing UAV technologies. Those areas of research include: low cost composite materials manufacturing, geomagnetic data acquisition, obstacle detection, autonomous operations and magnetic signature control. In this thesis work a methodology for designing and manufacturing inserts for foam-core sandwich structures was developed. The results of this research work enables a designer wishing to design a foam-core sandwich airframe structure, a means of quickly manufacturing optimized inserts for the safe introduction of discrete loads into the airframe. The previous GeoSury II Prototype insert designs (v.1 & v.2) were performance tested to establish a benchmark with which to compare future insert designs. Several designs and materials were considered for the new v.3 inserts. A plug and sleeve design was selected, due to its ability to effectively transfer the required loads to the sandwich structure. The insert material was chosen to be epoxy, reinforced with chopped carbon fibre. This material was chosen for its combination of strength, low mass and also compatibility with the face-sheet material. The v.3 insert assembly is 60% lighter than the

  3. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    Science.gov (United States)

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

  4. Heterojunction photodetector based on graphene oxide sandwiched between ITO and p-Si

    Science.gov (United States)

    Ahmad, H.; Tajdidzadeh, M.; Thandavan, T. M. K.

    2018-02-01

    The drop casting method is utilized on indium tin oxide (ITO)-coated glass in order to prepare a sandwiched ITO/graphene oxide (ITO/GO) with silicon dioxide/p-type silicon (SiO2/p-Si) heterojunction photodetector. The partially sandwiched GO layer with SiO2/p-Si substrate exhibits dual characteristics as it showed good sensitivity towards the illumination of infrared (IR) laser at wavelength of 974 nm. Excellent photoconduction is also observed for current-voltage (I-V) characteristics at various laser powers. An external quantum efficiency greater than 1 for a direct current bias voltage of 0 and 3 V reveals significant photoresponsivity of the photodetector at various laser frequency modulation at 1, 5 and 9 Hz. The rise times are found to be 75, 72 and 70 μs for 1, 5 and 9 Hz while high fall times 455, 448 and 426 are measured for the respective frequency modulation. The fabricated ITO/GO-SiO2/p-Si sandwiched heterojunction photodetector can be considered as a good candidate for applications in the IR regions that do not require a high-speed response.

  5. Sandwich radioimmunolabeling for the study of surface properties of bone marrow lymphocytes

    International Nuclear Information System (INIS)

    Yoshida, Y.; Uchino, H.; Kuribayashi, K.; Shimizu, S.; Konda, S.

    1980-01-01

    A modification of sandwich radioautographic method was applied to the study of surface immunoglobulin and/or specific antigens on small lymphocytes in mouse and human bone marrow. After incubation of marrow cell suspensions at 37 0 C, cells were reacted at 0 0 C for 30 min with graded dilutions of rabbit anti-mouse or anti-human immunoglobulin followed by further reaction with a sheep anti-rabbit immunoglobulin labeled with 125 I. Detectable surface immunoglobulin was demonstrated in approximately one-third of mouse marrow lymphocytes and 20-25% of human marrow lymphocytes. The densities of surface immunoglobulin as assessed by grain counts on individual labeled lymphocytes tended to be lower in the marrow than in spleen or peripheral blood. When the same rabbit antiserum was used to compare the sensitivity of the sandwich method with that of the direct radioautography, the former was found sufficiently sensitive to give a plateau level of labeling without seriously increasing background grains. The advantages of the method are discussed with reference to studies on T and B cell specific antigens on human bone marrow lymphocytes. (Auth.)

  6. Nanocrystalline Aluminum Truss Cores for Lightweight Sandwich Structures

    Science.gov (United States)

    Schaedler, Tobias A.; Chan, Lisa J.; Clough, Eric C.; Stilke, Morgan A.; Hundley, Jacob M.; Masur, Lawrence J.

    2017-12-01

    Substitution of conventional honeycomb composite sandwich structures with lighter alternatives has the potential to reduce the mass of future vehicles. Here we demonstrate nanocrystalline aluminum-manganese truss cores that achieve 2-4 times higher strength than aluminum alloy 5056 honeycombs of the same density. The scalable fabrication approach starts with additive manufacturing of polymer templates, followed by electrodeposition of nanocrystalline Al-Mn alloy, removal of the polymer, and facesheet integration. This facilitates curved and net-shaped sandwich structures, as well as co-curing of the facesheets, which eliminates the need for extra adhesive. The nanocrystalline Al-Mn alloy thin-film material exhibits high strength and ductility and can be converted into a three-dimensional hollow truss structure with this approach. Ultra-lightweight sandwich structures are of interest for a range of applications in aerospace, such as fairings, wings, and flaps, as well as for the automotive and sports industries.

  7. Blast-Resistant Improvement of Sandwich Armor Structure with Aluminum Foam Composite

    OpenAIRE

    Yang, Shu; Qi, Chang

    2013-01-01

    Sandwich armor structures with aluminum foam can be utilized to protect a military vehicle from harmful blast load such as a landmine explosion. In this paper, a system-level dynamic finite element model is developed to simulate the blast event and to evaluate the blast-resistant performance of the sandwich armor structure. It is found that a sandwich armor structure with only aluminum foam is capable of mitigating crew injuries under a moderate blast load. However, a severe blast load causes...

  8. Validation of a digital photographic method for assessment of dietary quality of school lunch sandwiches brought from home

    DEFF Research Database (Denmark)

    Sabinsky, Marianne; Toft, Ulla; Andersen, Klaus K

    2013-01-01

    Background: It is a challenge to assess children’s dietary intake. The digital photographic method (DPM) may be an objective method that can overcome some of these challenges. Objective: The aim of this study was to evaluate the validity and reliability of a DPM to assess the quality of dietary....... The lunches were photographed using a standardised DPM. From the digital images, the dietary components were estimated by a trained image analyst using weights or household measures and the dietary quality was assessed using a validated Meal Index of Dietary Quality (Meal IQ). The dietary components...... and the Meal IQ obtained from the digital images were validated against the objective weighed foods of the school lunch sandwiches. To determine interrater reliability, the digital images were evaluated by a second image analyst. Results: Correlation coefficients between the DPM and the weighed foods ranged...

  9. Analysis and Behaviour of Sandwich Panels with Profiled Metal Facings under Transverse Load

    Directory of Open Access Journals (Sweden)

    M. Budescu

    2004-01-01

    Full Text Available Sandwich panels with thin steel facings and polyurethane core combine the load-carrying capacity of metal facings and protection functions with core properties. The core separates the two facings and keeps them in a stable condition, transmits shear between external layers, provides most of the shear rigidity and occasionally makes of useful contribution to the bending stiffness of the sandwich construction as a whole [1]. An experimental program on sandwich panels has been organized to prove that the mechanical properties of core and interface satisfy the load-carrying requirements for structural sandwich panels. The analysis of sandwich panels with deep profiles facings for cladding elements, respectively the roof constructions, has been carried out according to the European design norms [1], [5].

  10. Effect of varying geometrical parameters of trapezoidal corrugated-core sandwich structure

    Directory of Open Access Journals (Sweden)

    Zaid N.Z.M.

    2017-01-01

    Full Text Available Sandwich structure is an attractive alternative that increasingly used in the transportation and aerospace industry. Corrugated-core with trapezoidal shape allows enhancing the damage resistance to the sandwich structure, but on the other hand, it changes the structural response of the sandwich structure. The aim of this paper is to study the effect of varying geometrical parameters of trapezoidal corrugated-core sandwich structure under compression loading. The corrugated-core specimen was fabricated using press technique, following the shape of trapezoidal shape. Two different materials were used in the study, glass fibre reinforced plastic (GFRP and carbon fibre reinforced plastic (CFRP. The result shows that the mechanical properties of the core in compression loading are sensitive to the variation of a number of unit cells and the core thickness.

  11. Long sandwich modules for photon veto detectors

    International Nuclear Information System (INIS)

    Yershov, N.; Khabibullin, M.; Kudenko, Yu.; Littenberg, L.; Mayatski, V.; Mineev, O.

    2005-01-01

    Long lead-scintillator sandwich modules developed for the BNL experiment KOPIO are described. The individual 4 m long module consists of 15 layers of 7 mm thick extruded scintillator and 15 layers of 1 mm lead absorber. Readout is implemented via WLS fibers glued into grooves in a scintillator with 7 mm spacing and viewed from both ends by the phototubes. Time resolution of 300 ps for cosmic MIPs was obtained. Light output stability monitored for 2 years shows no degradation beyond the measurement errors. A 4 m long C-bent sandwich module was also manufactured and tested

  12. Consistency of direct microscopic examination and ELISA in detection of Giardia in stool specimen among children

    Directory of Open Access Journals (Sweden)

    Zohreh Torabi

    2014-09-01

    Full Text Available Objective: To investigate the consistency of direct microscopic examination and ELISA for determination of Giadia in stool specimen. Method: Study population consisted of children with any clinical symptoms of Giardia infestation since last two weeks. Fresh stool specimen was collected from each child. The stools specimens were assessed by two methods of direct microscopic examination and ELISA.The degree of agreement between direct stool exam and ELISA was calculated by Cohen's kappa coefficient. Results: In this study, 124 children with age range 2-12 years were investigated. A total of 64 (61.7% and 79 (65.7% of children had Giardia by direct stool exam and ELISA test respectively. There was association between frequency of constipation and Giardia infection (P=0.036. The Cohen's kappa coefficient calculated for degree of agreement between direct stool exam and ELISA showed κ=0.756 (P<0.001. Conclusions: The frequency of Giardia infection in symptomatic children was high and there was high agreement rate between ELISA and direct stool smear.

  13. Application of fibre reinforced plastic sandwich structures for automotive crashworthiness applications

    NARCIS (Netherlands)

    Lukaszewicz, D.; Blok, L.G.; Kratz, J.; Ward, C.; Kassapoglou, C.; Elmarakbi, A.; Araújo, A.L.

    2016-01-01

    In this work the application of fibre reinforced plastic (FRP) sandwich
    structures, with particular focus on aramid fibre tufted sandwiches is being studied for
    automotive crashworthiness applications using impact testing and numerical simulation.

  14. Mobile phone based ELISA (MELISA).

    Science.gov (United States)

    Zhdanov, Arsenii; Keefe, Jordan; Franco-Waite, Luis; Konnaiyan, Karthik Raj; Pyayt, Anna

    2018-04-30

    Enzyme-linked immunosorbent assay (ELISA) is one of the most important technologies for biochemical analysis critical for diagnosis and monitoring of many diseases. Traditional systems for ELISA incubation and reading are expensive and bulky, thus cannot be used at point-of-care or in the field. Here, we propose and demonstrate a new miniature mobile phone based system for ELISA (MELISA). This system can be used to complete all steps of the assay, including incubation and reading. It weighs just 1 pound, can be fabricated at low cost, portable, and can transfer test results via mobile phone. We successfully demonstrated how MELISA can be calibrated for accurate measurements of progesterone and demonstrated successful measurements with the calibrated system. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Application of Load Carrying Sandwich Elements in Wind Turbine Blades

    DEFF Research Database (Denmark)

    Jensen, Jacob Fisker; Schultz, Jacob Pagh; Berggreen, Carl Christian

    2005-01-01

    The present work investigates the possibilities and drawbacks when applying sandwich as opposed to single skin composites in the flanges of the load carrying spar in a future 180 m wind turbine rotor. FEA is applied to investigate two basic designs with single skin and sandwich flanges respectively...

  16. Compressive Behaviour and Energy Absorption of Aluminium Foam Sandwich

    Science.gov (United States)

    Endut, N. A.; Hazza, M. H. F. Al; Sidek, A. A.; Adesta, E. T. Y.; Ibrahim, N. A.

    2018-01-01

    Development of materials in automotive industries plays an important role in order to retain the safety, performance and cost. Metal foams are one of the idea to evolve new material in automotive industries since it can absorb energy when it deformed and good for crash management. Recently, new technology had been introduced to replace metallic foam by using aluminium foam sandwich (AFS) due to lightweight and high energy absorption behaviour. Therefore, this paper provides reliable data that can be used to analyze the energy absorption behaviour of aluminium foam sandwich by conducting experimental work which is compression test. Six experiments of the compression test were carried out to analyze the stress-strain relationship in terms of energy absorption behavior. The effects of input variables include varying the thickness of aluminium foam core and aluminium sheets on energy absorption behavior were evaluated comprehensively. Stress-strain relationship curves was used for energy absorption of aluminium foam sandwich calculation. The result highlights that the energy absorption of aluminium foam sandwich increases from 12.74 J to 64.42 J respectively with increasing the foam and skin thickness.

  17. Performance of microscopy and ELISA for diagnosing Giardia duodenalis infection in different pediatric groups.

    Science.gov (United States)

    Silva, Renata K N R; Pacheco, Flávia T F; Martins, Adson S; Menezes, Joelma F; Costa-Ribeiro, Hugo; Ribeiro, Tereza C M; Mattos, Ângela P; Oliveira, Ricardo R; Soares, Neci M; Teixeira, Márcia C A

    2016-12-01

    Techniques for Giardia diagnosis based on microscopy are usually applied as routine laboratory testing; however, they typically exhibit low sensitivity. This study aimed to evaluate Giardia duodenalis and other intestinal parasitic infections in different pediatric groups, with an emphasis on the comparison of Giardia diagnostic techniques. Feces from 824 children from different groups (diarrheic, malnourished, with cancer and from day care) were examined by microscopy and ELISA for Giardia, Cryptosporidium sp. and Entamoeba histolytica coproantigen detection. Giardia-positive samples from day-care children, identified by either microscopy or ELISA, were further tested by PCR targeting of the β-giardin and Gdh genes. Statistically significant differences (Psp. in diarrheic and malnourished groups; infections by Entamoeba histolytica were found only in children with diarrhea. Considering positivity for Giardia by at least one method, ELISA was found to be more sensitive than microscopy (97% versus 55%). To examine discrepancies among the diagnostic methods, 71 Giardia-positive stool samples from day-care children were tested by PCR; of these, DNA was amplified from 51 samples (77.4%). Concordance of positivity between microscopy and ELISA was found for 48 samples, with 43 confirmed by PCR. Parasite DNA was amplified from eleven of the 20 Giardia samples (55%) identified only by ELISA. This study shows the higher sensitivity of ELISA over microscopy for Giardia diagnosis when a single sample is analyzed and emphasizes the need for methods based on coproantigen detection to identify this parasite in diarrheic fecal samples. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. The use of filter paper plasticized with polyvinyl alcohol-glutaraldehyde in ELISA

    Directory of Open Access Journals (Sweden)

    G.H.T.S. Barbosa

    2000-07-01

    Full Text Available F1-antigen purified from Yersinia pestis was covalently linked to 5-mm diameter filter paper discs plasticized with polyvinyl alcohol-glutaraldehyde. These discs were used both for ELISA and dot-ELISA for the detection of anti-F1 IgG in rabbits. The best conditions were achieved using 1.25 µg of F1 antigen/disc, 3% w/v skim milk in PBS as blocking agent, anti-IgG peroxidase conjugate diluted 12,000 times, and serum from rabbits immunized or not against Y. pestis, diluted 6,400 times. The absorbance values obtained from the comparative study between this procedure and conventional ELISA were not significantly different but the low cost of the reagents employed in ELISA using the filter paper discs plasticized with polyvinyl alcohol-glutaraldehyde makes this method economically attractive.

  19. A new ELISA for determination of potency in snake antivenoms.

    Science.gov (United States)

    Rial, A; Morais, V; Rossi, S; Massaldi, H

    2006-09-15

    A competitive ELISA for potency determination of bothropic equine antivenom was developed and compared to the conventional in vivo ED(50) assay, with the aim of partially substituting the in vivo assay in the monitoring of antivenom immunoglobulin levels. On this purpose, blood samples were taken at different times during and after the immunization protocol of the lot of horses used for production of snake antivenom at the Instituto de Higiene, Uruguay. Both the competitive ELISA and the ED(50) assay were performed on those samples. In addition, a group of five commercial pepsin-digested antivenoms were tested by both methods. A significant (P<0.001) correlation (Pearson's r=0.957) was found between the ELISA titres and the corresponding ED(50) values, indicating that the in vitro test can estimate the neutralizing antibody capacity of the sera as well as the in vivo assay. By means of this new ELISA, it was found that the immunized animals maintained good venom antibody titres, in the order of 20-50% of the maximum achieved, even 10 month after the end of the immunization schedule. The main advantage of our ELISA design is its ability to correctly estimate the neutralization capacity of crude hyperimmune plasma and antivenom sera independently of their antibody composition in terms of whole IgG or F(ab')(2) fragment.

  20. High affinity γPNA sandwich hybridization assay for rapid detection of short nucleic acid targets with single mismatch discrimination.

    Science.gov (United States)

    Goldman, Johnathan M; Zhang, Li Ang; Manna, Arunava; Armitage, Bruce A; Ly, Danith H; Schneider, James W

    2013-07-08

    Hybridization analysis of short DNA and RNA targets presents many challenges for detection. The commonly employed sandwich hybridization approach cannot be implemented for these short targets due to insufficient probe-target binding strengths for unmodified DNA probes. Here, we present a method capable of rapid and stable sandwich hybridization detection for 22 nucleotide DNA and RNA targets. Stable hybridization is achieved using an n-alkylated, polyethylene glycol γ-carbon modified peptide nucleic acid (γPNA) amphiphile. The γPNA's exceptionally high affinity enables stable hybridization of a second DNA-based probe to the remaining bases of the short target. Upon hybridization of both probes, an electrophoretic mobility shift is measured via interaction of the n-alkane modification on the γPNA with capillary electrophoresis running buffer containing nonionic surfactant micelles. We find that sandwich hybridization of both probes is stable under multiple binding configurations and demonstrate single base mismatch discrimination. The binding strength of both probes is also stabilized via coaxial stacking on adjacent hybridization to targets. We conclude with a discussion on the implementation of the proposed sandwich hybridization assay as a high-throughput microRNA detection method.

  1. Easy instrumental analysis

    International Nuclear Information System (INIS)

    Ko, Myeong Su; Kim, Tae Hwa; Park, Gyu Hyeon; Yang, Jong Beom; Oh, Chang Hwan; Lee, Kyoung Hye

    2010-04-01

    This textbook describes instrument analysis in easy way with twelve chapters. The contents of the book are pH measurement on principle, pH meter, pH measurement, examples of the experiments, centrifugation, Absorptiometry, Fluorescent method, Atomic absorption analysis, Gas-chromatography, Gas chromatography-mass spectrometry, High performance liquid chromatography liquid chromatograph-mass spectrometry, Electrophoresis on practical case and analysis of the result and examples, PCR on principle, device, application and examples and Enzyme-linked immunosorbent assay with indirect ELISA, sandwich ELISA and ELISA reader.

  2. Easy instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Myeong Su; Kim, Tae Hwa; Park, Gyu Hyeon; Yang, Jong Beom; Oh, Chang Hwan; Lee, Kyoung Hye

    2010-04-15

    This textbook describes instrument analysis in easy way with twelve chapters. The contents of the book are pH measurement on principle, pH meter, pH measurement, examples of the experiments, centrifugation, Absorptiometry, Fluorescent method, Atomic absorption analysis, Gas-chromatography, Gas chromatography-mass spectrometry, High performance liquid chromatography liquid chromatograph-mass spectrometry, Electrophoresis on practical case and analysis of the result and examples, PCR on principle, device, application and examples and Enzyme-linked immunosorbent assay with indirect ELISA, sandwich ELISA and ELISA reader.

  3. Sandwiched Rényi divergence satisfies data processing inequality

    International Nuclear Information System (INIS)

    Beigi, Salman

    2013-01-01

    Sandwiched (quantum) α-Rényi divergence has been recently defined in the independent works of Wilde et al. [“Strong converse for the classical capacity of entanglement-breaking channels,” preprint http://arxiv.org/abs/arXiv:1306.1586 (2013)] and Müller-Lennert et al. [“On quantum Rényi entropies: a new definition, some properties and several conjectures,” preprint http://arxiv.org/abs/arXiv:1306.3142v1 (2013)]. This new quantum divergence has already found applications in quantum information theory. Here we further investigate properties of this new quantum divergence. In particular, we show that sandwiched α-Rényi divergence satisfies the data processing inequality for all values of α > 1. Moreover we prove that α-Holevo information, a variant of Holevo information defined in terms of sandwiched α-Rényi divergence, is super-additive. Our results are based on Hölder's inequality, the Riesz-Thorin theorem and ideas from the theory of complex interpolation. We also employ Sion's minimax theorem

  4. Multi-objective optimal design of sandwich panels using a genetic algorithm

    Science.gov (United States)

    Xu, Xiaomei; Jiang, Yiping; Pueh Lee, Heow

    2017-10-01

    In this study, an optimization problem concerning sandwich panels is investigated by simultaneously considering the two objectives of minimizing the panel mass and maximizing the sound insulation performance. First of all, the acoustic model of sandwich panels is discussed, which provides a foundation to model the acoustic objective function. Then the optimization problem is formulated as a bi-objective programming model, and a solution algorithm based on the non-dominated sorting genetic algorithm II (NSGA-II) is provided to solve the proposed model. Finally, taking an example of a sandwich panel that is expected to be used as an automotive roof panel, numerical experiments are carried out to verify the effectiveness of the proposed model and solution algorithm. Numerical results demonstrate in detail how the core material, geometric constraints and mechanical constraints impact the optimal designs of sandwich panels.

  5. Design Considerations for Thermally Insulating Structural Sandwich Panels for Hypersonic Vehicles

    Science.gov (United States)

    Blosser, Max L.

    2016-01-01

    Simplified thermal/structural sizing equations were derived for the in-plane loading of a thermally insulating structural sandwich panel. Equations were developed for the strain in the inner and outer face sheets of a sandwich subjected to uniaxial mechanical loads and differences in face sheet temperatures. Simple equations describing situations with no viable solution were developed. Key design parameters, material properties, and design principles are identified. A numerical example illustrates using the equations for a preliminary feasibility assessment of various material combinations and an initial sizing for minimum mass of a sandwich panel.

  6. Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Konstantinou, George N

    2017-01-01

    Food allergy is a public health concern especially after recognizing its constantly increased prevalence and severity. Despite careful reading of food ingredient statements, food allergic individuals may experience reactions caused by "hidden", "masked", or "contaminated" proteins that are known major allergens. Many techniques have been developed to detect even small traces of food allergens, for clinical or laboratory purposes. Enzyme-linked immunosorbent assay (ELISA) is one of the best validated and most routinely used immunoassay in allergy research, in allergy diagnosis in allergy-related quality control in various industries. Although as a technique it has been implemented for the last 45 years, the evolution in biochemistry allowed the development of ultrasensitive ELISA variations that are capable of measuring quantities in the scale of picograms, rendering ELISA attractive, robust, and very famous.

  7. The Planar Sandwich and Other 1D Planar Heat Flow Test Problems in ExactPack

    Energy Technology Data Exchange (ETDEWEB)

    Singleton, Jr., Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-24

    This report documents the implementation of several related 1D heat flow problems in the verification package ExactPack [1]. In particular, the planar sandwich class defined in Ref. [2], as well as the classes PlanarSandwichHot, PlanarSandwichHalf, and other generalizations of the planar sandwich problem, are defined and documented here. A rather general treatment of 1D heat flow is presented, whose main results have been implemented in the class Rod1D. All planar sandwich classes are derived from the parent class Rod1D.

  8. Abuelgassim and Al-Showayman Afr J Tradit Complement Altern ...

    African Journals Online (AJOL)

    AJTCAM

    C reactive protein (CRP) levels in serum were determined by the sandwich ELISA ... of diluted samples was assayed by Biuret method (Gornall et al., 1949). ... The data presented in this investigation are expressed as means ± standard error ...

  9. Buckling Analysis of Edge Cracked Sandwich Plate

    Directory of Open Access Journals (Sweden)

    Rasha Mohammed Hussein

    2016-07-01

    Full Text Available This work presents mainly the buckling load of sandwich plates with or without crack for different cases. The buckling loads are analyzed experimentally and numerically by using ANSYS 15. The experimental investigation was to fabricate the cracked sandwich plate from stainless steel and PVC to find mechanical properties of stainless steel and PVC such as young modulus. The buckling load for different aspect ratio, crack length, cracked location and plate without crack found. The experimental results were compared with that found from ANSYS program. Present of crack is decreased the buckling load and that depends on crack size, crack location and aspect ratio.

  10. Behavior of composite sandwich panels with several core designs at different impact velocities

    Science.gov (United States)

    Jiga, Gabriel; Stamin, Ştefan; Dinu, Gabriela

    2018-02-01

    A sandwich composite represents a special class of composite materials that is manufactured by bonding two thin but stiff faces to a low density and low strength but thick core. The distance between the skins given by the core increases the flexural modulus of the panel with a low mass increase, producing an efficient structure able to resist at flexural and buckling loads. The strength of sandwich panels depends on the size of the panel, skins material and number or density of the cells within it. Sandwich composites are used widely in several industries, such as aerospace, automotive, medical and leisure industries. The behavior of composite sandwich panels with different core designs under different impact velocities are analyzed in this paper by numerical simulations performed on sandwich panels. The modeling was done in ANSYS and the analysis was performed through LS-DYNA.

  11. Pengaruh perlakuan serat tapis kelapa terhadap kekuatan lentur skin komposit sandwich

    Directory of Open Access Journals (Sweden)

    I Made Astika

    2018-01-01

    polyester resin, albasia wood, NaOH and 1% concentration hardener. Skin of composite sandwich consists of the fibers without treatment and 2 hours alkali treatment. Composite sandwich composed of two skins with a core in the middle and production method by hydraulic molding press. Lamina composite as a skin made of 30% volume fraction and 15 mm fiber length Flexural specimens and testing procedures based on ASTM C 393 standards. The results showed that fibers get 2 hours NaOH alkaline treatment resulted in a higher flexural strength. This is because the alkali treatment on coconut filter fiber can clean the wax layer (lignin and dirt on the surface of the fiber resulting in better mechanical interlocking between the fibers with polyester matrix. Keywords: composite sandwich, coconut filter fiber, NaOH alkaline treatment, flexural strength

  12. Methodology for determination of plasma cortisol in fish using Competitive Enzyme-Linked Immunosorbent Assay (ELISA)

    DEFF Research Database (Denmark)

    Velasco-Santamaría, Yohana M.; Cruz-Casallas, Pablo E.

    2007-01-01

    Objective. To determine plasma cortisol procedure in fish using competitive enzymelinked immunosorbent assay (ELISA). Materials and methods. Two plasma samples of juveniles rainbow trout Oncorhynchus mykiss were analized by using ELISA human kit for cortisol assay. For standard curve calibration...

  13. Diagnosis of Caprine Arthritis Encephalitis Virus infection in dairy goats by ELISA, PCR and Viral Culture.

    Science.gov (United States)

    Panneum, S; Rukkwamsuk, T

    2017-03-01

    For preventive and control strategies of Caprine Arthritis Encephalitis Virus (CAEV) infection in dairy goats, performance of the available diagnostic tests was described as one of the most important and necessary aspects. The study aimed at evaluating the diagnostic test performance, including PCR, ELISA and viral culture, for CAEV infection in dairy goats in Thailand. Blood samples of 29 dairy goats from five low- to medium-prevalence herds and one very low-prevalence herd were collected for PCR and ELISA methods. The performance of these two diagnostic methods was evaluated by comparing with cytopathic effects (CPE) in the co-cultivation of CAEV and primary synovial cells. Results indicated that sensitivity, specificity were, respectively, 69.6%, 100%, for PCR; and 95.7%, 83.3% for ELISA. The PCR assay tended to have lower sensitivity and higher specificity than ELISA. When multiple tests were applied, parallel testing provided sensitivity and specificity of 98.7% and 83.3%, while series testing showed sensitivity and specificity of 66.6% and 100% respectively. These results indicated that combination of ELISA and PCR provided some advantages and possibly offered optimal methods to detect CAEV-infected goats. Kappa value of the agreement between PCR and ELISA test was 0.34, indicating fair agreement. Regarding the possibility of antigenic variation between CAEV strains used in both PCR and ELISA assays, the actual circulating CAEV strain should be reviewed in order to develop and enhance the diagnostic tests using the CAE viral antigens derived from specific local strains of Thailand.

  14. One-pot synthesis of Ag-SiO2-Ag sandwich nanostructures

    International Nuclear Information System (INIS)

    Li Chaorong; Mei Jie; Li Shuwen; Lu Nianpeng; Wang Lina; Chen Benyong; Dong Wenjun

    2010-01-01

    Ag-SiO 2 -Ag sandwich nanostructures were prepared by a facile one-pot synthesis method. The Ag core, SiO 2 shell and Ag nanoparticle shell were all synthesized with polyvinylpyrrolidone, catalysed by ammonia, in the one-pot reaction. The polyvinylpyrrolidone, acting as a smart reducing agent, reduced the Ag + to Ag cores and Ag shells separately. Furthermore, the polyvinylpyrrolidone served as a protective agent to prevent the silver cores from aggregating. The SiO 2 shell and outer layer Ag nanoparticles were obtained when tetraethyl orthosilicate and ammonia were added to the silver core solution. Ammonia, acting as the catalyst, accelerated the hydrolysis of the tetraethyl orthosilicate to SiO 2 , which coated the silver cores. Furthermore, Ag(NH 3 ) 2 + ions were formed when aqueous ammonia was added to the solution, which increased the reduction capability. Then the polyvinylpyrrolidone reduced the Ag(NH 3 ) 2 + ions to small Ag nanoparticles on the surface of the Ag-SiO 2 and formed Ag-SiO 2 -Ag sandwich structures with a standard deviation of less than 4%. This structure effectively prevented the Ag nanoparticles on the silica surface from aggregating. Furthermore, the Ag-SiO 2 -Ag sandwich structures showed good catalysis properties due to the large surface area/volume value and activity of surface atoms of Ag particles.

  15. Bayesian estimation of sensitivity and specificity of Coxiella burnetii antibody ELISA tests in bovine blood and milk

    DEFF Research Database (Denmark)

    Paul, Suman; Toft, Nils; Agerholm, Jørgen S.

    2013-01-01

    Serological tests for Coxiella burnetii (the causative agent of Q fever) antibodies are usually based on enzyme linked immunosorbent assay (ELISA) although this method is not thoroughly evaluated. The objective of this study was to determine the sensitivity and specificity of an ELISA for detection...... lactating cows is relatively easy, non-invasive and inexpensive and hence milk ELISA may be a better option for screening lactating cows. But, blood ELISA is an option for screening non-lactating cattle....

  16. Parametric study on nonlinear vibration of composite truss core sandwich plate with internal resonance

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jia Nen; Liu, Jun [Tianjin Key Laboratory of the Design and Intelligent Control of the Advanced Mechatronical System, Tianjin University of Technology, Tianjin (China); Zhang, Wei; Yao, Ming Hui [College of Mechanical Engineering, Beijing University of Technology, Beijing (China); Sun, Min [School of Science, Tianjin Chengjian University, Tianjin (China)

    2016-09-15

    Nonlinear vibrations of carbon fiber reinforced composite sandwich plate with pyramidal truss core are investigated. The governing equation of motion for the sandwich plate is derived by using a Zig-Zag theory under consideration of geometrically nonlinear. The natural frequencies of sandwich plates with different dimensions are calculated and compared with those obtained from the classic laminated plate theory and Reddy's third-order shear deformation plate theory. The frequency responses and waveforms of the sandwich plate when 1:3 internal resonance occurs are obtained, and the characteristics of the internal resonance are discussed. The influences of layer number of face sheet, strut radius, core height and inclination angle on the nonlinear responses of the sandwich plate are analyzed. The results demonstrate that the strut radius and inclination angle mainly affect the resonance frequency band of the sandwich plate, and the layer number and core height not only influence the resonance frequency band but also significantly affect the response amplitude.

  17. [Effect evaluation of three ELISA kits in detection of fasciolasis].

    Science.gov (United States)

    Ai, Lin; Chen, Mu-Xin; Chen, Shao-Hong; Chu, Yan-Hong; Cai, Yu-Chun; Zhou, Xiao-Nong; Chen, Jia-Xu

    2013-04-01

    To evaluate the effect of 3 ELISA kits on detection of human fasciolasis. Twenty-six serum samples from patients with fasciolasis, 180 serum samples from patients with other parasitic diseases as well as 26 serum samples from healthy people were detected by ELISA kits which using soluble antigen of Fasciola gigantica, Fasciola hepatica (Fg-ELISA and Fh-ELISA) as well as IgG antigen ELISA detection kits made by DRG company in Germany. The effects of the 3 kits were evaluated. The sensitivities of Fg-ELISA, Fh-ELISA, and DRG-ELISA were 100.0%, 80.8% (95% CI: 65.7%-95.9%) and 100.0%, respectively; the specificities of the three were 87.9% (95% CI: 83.5%-92.4%), 85.0%(95% CI: 80.1%-89.9%) and 83.5% (95% CI: 78.4%-88.6%), respectively, and Youden indexes of them were 0.88, 0.66 and 0.84, respectively. The detection rate of Fg-ELISA (100%) was significantly higher than that of Fh-ELISA (80.8%) (P DRG-ELISA for clinical sample tests as well as massive screening in fasciolasis endemic areas in southwest China.

  18. E.L.I.S.A. en coccidioidomicosis humana E.L.I.S.A. in human coccidioidomycosis

    Directory of Open Access Journals (Sweden)

    Iris Nora Tiraboschi

    1991-08-01

    Full Text Available Se realizó E.L.I.S.A. con exoantígeno de Coccidioides immitis para la detectión de anticuerpos, en 67 sueros humanos diluidos 1/1000, 1/2000, 1/4000 y 1/8000. De los 18 sueros de enfermos de coccidioidomicosis comprobada por examen directo, cultivo y/o histología, 5 fueron negativos, en otros 13 fueron positivos en una o varias diluciones. 3/26 sueros de personas sanas, coccidioidino positivas, fueron positivos en títulos de 1/1000 y el resto no tuvo anticuerpos detectables. No presentaron reacciones positivas ninguno de los sueros controles de personas sanas, pero sí lo hicieron 4/8 pacientes con otras micosis. Se concluye que E.L.I.S.A. es útil para la detección de mínimas cantidades de anticuerpos o en sueros que no pueden ser procesados por fijación de complemento. No es recomendable el uso de la técnica en forma aislada por al presencia de reacciones cruzadas.An E.L.I.S.A. test for antibody detection, with an exo-antigen of Coccidioides immitis was standardized in 67 humans sera diluited in 1/1000, 1/2000, 1/4000 and 1/8000. Eightheen sera from mycologically proved cases of coccidioidomycosis were studied: 5 were negative and 13 were positive in some dilutions. 3/26 sera of healthy persons who presented positive skin tests with coccidioidin were positive and the other 23 sera did not have positive reactions. None of the 15 sera of healthy human exhibited positive E.L.I.S.A. Serum samples of 8 patients suffering other deep mycosis were studied, 4 of them presented cross-reactions in E.L.I.S.A. tests. E.L.I.S.A. test seems to be a useful Serologic technique for antibody detection in anticomplementary serum samples or when a low concentration of antibodies should be detected. As it is very sensitive, cross-reactions with other mycoses are frequent, thus the use other more specific serologic technique together E.L.I.S.A. is recommended.

  19. Enhancing the imaging quality and fabrication efficiency of bionic compound eyes using a sandwich structure

    Science.gov (United States)

    Luo, Jiasai; Guo, Yongcai; Wang, Xin

    2018-06-01

    This paper puts forward a novel method for fabrication of sandwich-structured BCE using a detachable micro-hole array (MHA) prepared by 3D printing. Compared with most traditional methods, 3D printing enables effective implementation of direct micro-fabrication for curved BCE without the pattern transfer and substrate reshaping process. This 3D fabrication method allows rapid fabrication of the curved BCE and automatic assembly of the detachable MHA using a custom-built mold under negative pressure. The formation of a multi-focusing micro-lens array (MLA) was realized by adjusting the parameters of the curved detachable MHA. The imaging performance was effectively enhanced by the sandwich structure that consist of the multi-focusing MLA, the outer detachable MHA and the inner solidified MHA. This method is suitable for mass production due to its advantages as a time-saving, cost-effective and simple process. Optical design software was used to analyze the optical properties, and an imaging simulation was performed.

  20. Detection of tetracosactide in plasma by enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Martin, Laurent; Chaabo, Ayman; Lasne, Françoise

    2015-06-01

    As a synthetic analogue of adrenocorticotropic hormone (ACTH), tetracosactide is prohibited in sport by the World Anti-Doping Agency (WADA). An enzyme-linked immunosorbent assay (ELISA) method is proposed for detection of this drug in plasma. Since its structure corresponds to the 24 N-terminal of the 39 amino acids of the natural endogenous peptide ACTH, tetracosactide can be detected with a commercial ELISA kit for ACTH that uses antibodies, the epitopes of which are located in the 1-24 part of ACTH. However, an essential condition for detection specificity is the preliminary total clearance of endogenous ACTH in the plasma samples. This is achieved by a preparative step based on cation-exchange chromatography before ELISA. The method is specific and sensitive (LOD: 30 pg/mL) and may be used as a screening analysis in anti-doping control. The pre-analytical conditions are shown to be of the upmost importance and recommendations for blood collection (EDTA tubes), sample transport (4 °C) and plasma sample storage (-20 °C) are presented. Copyright © 2014 John Wiley & Sons, Ltd.

  1. Failure Investigation of Debonded Sandwich Columns: An Experimental and Numerical Study

    DEFF Research Database (Denmark)

    Moslemian, Ramin; Berggreen, Christian; Carlsson, Leif A.

    2009-01-01

    Failure of compression loaded sandwich columns with an implanted through-width face/core debond is examined. Compression tests were conducted on sandwich columns containing implemented face/core debonds. The strains and out-of-plane displacements of the debonded region were monitored using the di...

  2. ANALYSIS OF SOIL AND DUST SAMPLES FOR POLYCHLORINATED BIPHENYLS BY ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)

    Science.gov (United States)

    An inhibition enzyme-linked immunosorbent assay (ELISA) was used to determine polychlorinated biphenyls (PCBs) in house dust and soil. Soil and house dust samples were analyzed for PCB by both gas chromatography/electron capture detection (GC/ECD) and ELISA methods. A correlati...

  3. Design and test of lightweight sandwich T-joint for naval ships

    DEFF Research Database (Denmark)

    Toftegaard, H.; Lystrup, Aa.

    2005-01-01

    Within the EUCLID project, 'Survivability, Durability and Performance of Naval Composite Structures', one task is to develop improved fibre composite joints for naval ship super structures. One type of joint in such a super structure is a T-joint between sandwich panels. An existing design consists...... of panels joined by filler and overlaminates of the same thickness as the skin laminates. Various improved T-joints have been designed and investigated. Some with focus on improved strength (survivability), and others with focus on reduced weight. This paper describes the design and test of a sandwich T...... triangles). A method for a finite element (FE) parameter study is developed and used for selection of a promising (strong) configuration of the T-joint. Tensile (pull-out) tests are performed to load the core triangles and filler in tension and the strength and failure mode are compared both with the FE...

  4. A novel indirect ELISA for diagnosis of dengue fever

    Directory of Open Access Journals (Sweden)

    Rohan Narayan

    2016-01-01

    Full Text Available Background & objectives: Dengue fever (DF is associated with significant morbidity and mortality in the tropical and sub-tropical regions of the world. Since there are no effective antiviral drugs for treatment, clinicians often rely on the accurate diagnosis of dengue fever to begin supportive therapy at early stages of the illness. The objective of this study was to develop an in-house dengue virus serotype 2 (DENV-2 non-structural protein- 5 (NS5 based indirect ELISA. Methods: DENV-2 was raised in Vero cells and the viral proteins were separated and subsequently the NS5 protein was eluted. Serum samples from primary and secondary dengue fever patients; and acute and convalescent samples from Japanese encephalitis (JE and West Nile virus (WNV cases were used to validate the ELISA. Results: The assay was found to be 100 per cent specific in detecting DENV-2 specific antibodies from patient′s serum. However, in terms of sensitivity, the assay could detect IgM antibodies only from 90 per cent of the primary dengue samples. The IgM/IgG ratio of the primary and secondary samples was 7.24 and 0.64, respectively. Interpretation & conclusions: The results indicate that the DENV-2 NS5 ELISA is dengue group specific and can be used to differentiate dengue infection from other circulating Flavivirus infections. This NS5 ELISA can also be used to distinguish between primary and secondary dengue fever on the basis of IgM/IgG ratios. Further studies with larger sample sizes and different DENV serotypes are required to validate the ELISA.

  5. Natural cork agglomerate employed as an environmentally friendly solution for quiet sandwich composites.

    Science.gov (United States)

    Sargianis, James; Kim, Hyung-ick; Suhr, Jonghwan

    2012-01-01

    Carbon fiber-synthetic foam core sandwich composites are widely used for many structural applications due to their superior mechanical performance and low weight. Unfortunately these structures typically have very poor acoustic performance. There is increasingly growing demand in mitigating this noise issue in sandwich composite structures. This study shows that marrying carbon fiber composites with natural cork in a sandwich structure provides a synergistic effect yielding a noise-free sandwich composite structure without the sacrifice of mechanical performance or weight. Moreover the cork-core sandwich composites boast a 250% improvement in damping performance, providing increased durability and lifetime operation. Additionally as the world seeks environmentally friendly materials, the harvesting of cork is a natural, renewable process which reduces subsequent carbon footprints. Such a transition from synthetic foam cores to natural cork cores could provide unprecedented improvements in acoustic and vibrational performance in applications such as aircraft cabins or wind turbine blades.

  6. Flexural wave attenuation in a sandwich beam with viscoelastic periodic cores

    Science.gov (United States)

    Guo, Zhiwei; Sheng, Meiping; Pan, Jie

    2017-07-01

    The flexural-wave attenuation performance of traditional constraint-layer damping in a sandwich beam is improved by using periodic constrained-layer damping (PCLD), where the monolithic viscoelastic core is replaced with two periodically alternating viscoelastic cores. Closed-form solutions of the wave propagation constants of the infinite periodic sandwich beam and the forced response of the corresponding finite sandwich structure are theoretically derived, providing computational support on the analysis of attenuation characteristics. In a sandwich beam with PCLD, the flexural waves can be attenuated by both Bragg scattering effect and damping effect, where the attenuation level is mainly dominated by Bragg scattering in the band-gaps and by damping in the pass-bands. Affected by these two effects, when the parameters of periodic cores are properly selected, a sandwich beam with PCLD can effectively reduce vibrations of much lower frequencies than that with traditional constrained-layer damping. The effects of the parameters of viscoelastic periodic cores on band-gap properties are also discussed, showing that the average attenuation in the desired frequency band can be maximized by tuning the length ratio and core thickness to proper values. The research in this paper could possibly provide useful information for the researches and engineers to design damping structures.

  7. A novel SERRS sandwich-hybridization assay to detect specific DNA target.

    Directory of Open Access Journals (Sweden)

    Cécile Feuillie

    Full Text Available In this study, we have applied Surface Enhanced Resonance Raman Scattering (SERRS technology to the specific detection of DNA. We present an innovative SERRS sandwich-hybridization assay that allows specific DNA detection without any enzymatic amplification, such as is the case with Polymerase Chain Reaction (PCR. In some substrates, such as ancient or processed remains, enzymatic amplification fails due to DNA alteration (degradation, chemical modification or to the presence of inhibitors. Consequently, the development of a non-enzymatic method, allowing specific DNA detection, could avoid long, expensive and inconclusive amplification trials. Here, we report the proof of concept of a SERRS sandwich-hybridization assay that leads to the detection of a specific chamois DNA. This SERRS assay reveals its potential as a non-enzymatic alternative technology to DNA amplification methods (particularly the PCR method with several applications for species detection. As the amount and type of damage highly depend on the preservation conditions, the present SERRS assay would enlarge the range of samples suitable for DNA analysis and ultimately would provide exciting new opportunities for the investigation of ancient DNA in the fields of evolutionary biology and molecular ecology, and of altered DNA in food frauds detection and forensics.

  8. Interfacial Crack Arrest in Sandwich Panels with Embedded Crack Stoppers Subjected to Fatigue Loading

    DEFF Research Database (Denmark)

    Martakos, G.; Andreasen, J. H.; Berggreen, Christian

    2017-01-01

    A novel crack arresting device has been implemented in sandwich panels and tested using a special rig to apply out-of-plane loading on the sandwich panel face-sheets. Fatigue crack propagation was induced in the face-core interface of the sandwich panels which met the crack arrester. The effect o...

  9. LDRD final report on microencapsulated immunoreagents for development of one-step ELISA

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, C.C.; Singh, A.K.

    1997-08-01

    Microencapsulation of biological macromolecules was investigated as a method for incorporating the necessary immunoreagents into an improved enzyme-linked immunosorbant assay (ELISA) package that would self-develop. This self-contained ELISA package would eliminate the need for a trained technician to perform multiple additions of immunoreagent to the assay. Microencapsulation by insolution drying was selected from the many available microencapsulation methods, and two satisfactory procedures for microencapsulation of proteins were established. The stability and potential for rapid release of protein from these microencapsulates was then evaluated. The results suggest that the chosen method for protein entrapment produces microcapsules with a considerable amount of protein in the walls making these particular microcapsules unsuitable for their intended use.

  10. Archetypal sandwich-structured CuO for high performance non-enzymatic sensing of glucose

    Science.gov (United States)

    Meher, Sumanta Kumar; Rao, G. Ranga

    2013-02-01

    In the quest to enhance the selectivity and sensitivity of novel structured metal oxides for electrochemical non-enzymatic sensing of glucose, we report here a green synthesis of unique sandwich-structured CuO on a large scale under microwave mediated homogeneous precipitation conditions. The physicochemical studies carried out by XRD and BET methods show that the monoclinic CuO formed via thermal decomposition of Cu2(OH)2CO3 possesses monomodal channel-type pores with largely improved surface area (~43 m2 g-1) and pore volume (0.163 cm3 g-1). The fascinating surface morphology and pore structure of CuO is formulated due to homogeneous crystallization and microwave induced self assembly during synthesis. The cyclic voltammetry and chronoamperometry studies show diffusion controlled glucose oxidation at ~0.6 V (vs. Ag/AgCl) with extremely high sensitivity of 5342.8 μA mM-1 cm-2 and respective detection limit and response time of ~1 μM and ~0.7 s, under a wide dynamic concentration range of glucose. The chronoamperometry measurements demonstrate that the sensitivity of CuO to glucose is unaffected by the absence of dissolved oxygen and presence of poisoning chloride ions in the reaction medium, which essentially implies high poison resistance activity of the sandwich-structured CuO. The sandwich-structured CuO also shows insignificant interference/significant selectivity to glucose, even in the presence of high concentrations of other sugars as well as reducing species. In addition, the sandwich-structured CuO shows excellent reproducibility (relative standard deviation of ~2.4% over ten identically fabricated electrodes) and outstanding long term stability (only ~1.3% loss in sensitivity over a period of one month) during non-enzymatic electrochemical sensing of glucose. The unique microstructure and suitable channel-type pore architecture provide structural stability and maximum accessible electroactive surface for unimpeded mobility of glucose as well as the

  11. ELISA reader does not interfere by mobile phone radiofrequency radiation

    Science.gov (United States)

    Mortazavi, Seyyed Mohammad Javad; Baradaran-Ghahfarokhi, Hamid Reza; Abdi, Mohammad Reza; Baradaran-Ghahfarokhi, Milad; Mostafavi, Nayyer Sadat; Mahmoudi, Golshan; Berenjkoub, Nafiseh; Akmali, Zahra; Hossein-Beigi, Fahimeh; Arsang, Vajiheh

    2016-01-01

    Background: The increasing number of mobile phones can physically cause electromagnetic interference (EMI) in medical environments; can also cause errors in immunoassays in laboratories. The ELISA readers are widely used as a useful diagnostic tool for Enzymun colorimetric assay in medicine. The aim of this study was to investigate whether the ELISA reader could be interfered by the exposure to the 900 MHz cell phones in the laboratory. Materials and Methods: Human serum samples were collected from 14 healthy donors (9 women and 5 men) and each sample was divided into four aliquots and was placed into four batches for the in-vitro quantitative determination of human chorionic gonadotropin (hCG). During colorimetric reading of the first, second, and third batches, the ELISA reader (Stat Fax 2100, Awareness Technology, Inc., USA) was exposed to 0.5, 1.0, and 2.0 W exposure of 900 MHz radiation, respectively. For the forth batch (control group), no radiation was applied. All experiments were performed comparing ELISA read out results of the I, II, and III batches with the control batch, using the Wilcoxon test with criterion level of P = 0.050. Results: The final scores in the exposed batches I, II, and III were not statistically significant relative to the control batch (P > 0.05). The results showed that 900 MHz radiation exposure did not alter the ELISA measured levels of hCG hormone in I (P = 0.219), II (P = 0.909), and III (P = 0.056) batches compared to the control batch. Conclusion: This study showed that ELISA reader does not interfere by mobile phone RF radiation at a closed contact (less than 5 cm distance). However, we recommend that medical institutions discuss these issues in the context of their specific use of technologies and frame a policy that is clear and straightforward to guide staff, patients, and visitors. PMID:27376040

  12. Tailoring Sandwich Face/Core Interfaces for Improved Damage Tolerance

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Berggreen, Christian; Carlsson, Leif A.

    2010-01-01

    A face/core debond in a sandwich structure may propagate in the interface or kink into either the face or core. It is found that certain modifications of the face/core interface region influence the kinking behavior, which is studied experimentally in the present paper. A sandwich double cantilever....... The transition points where the crack kinks are identified and the influence of four various interface design modifications on the propagation path and fracture resistance are investigated....

  13. Effect of Different Concentration of Sodium Hydroxide [NaOH] on Kenaf Sandwich Structures

    Science.gov (United States)

    Aziz, M.; Halim, Z.; Othman, M.

    2018-01-01

    Sandwich panels are structures that made of three layers, low-density core inserted in between thin skin layers. This structures allow the achievement of excellent mechanical performance with low weight, thus this characteristic fulfil requirement to be use in aircraft application. In recent time, sandwich structures have been studied due to it has multifunction properties and lightweight. The aim of this study is to fabricate a composite sandwich structures with biodegradable material for face sheet [skin] where the fibre being treat with different concentration of sodium hydroxide [NaOH] with 10 and 20 hours of soaking time. Kenaf fibre [treated] reinforced epoxy will be used as skins and Nomex honeycomb is chosen to perform as core for this sandwich composite structure. The mechanical properties that are evaluated such as flexural strength and impact energy of kenaf fibre-reinforced epoxy sandwich structures. For flexural test, the optimum flexural strength is 13.4 MPa and impact strength is 18.3 J.

  14. The comparison of numerical models of a sandwich panel in the context of the core deformations at the supports

    Science.gov (United States)

    Pozorska, Jolanta; Pozorski, Zbigniew

    2018-01-01

    The paper presents the problem of static structural behavior of sandwich panels at the supports. The panels have a soft core and correspond to typical structures applied in civil engineering. To analyze the problem, five different 3-D numerical models were created. The results were compared in the context of core compression and stress redistribution. The numerical solutions verify methods of evaluating the capacity of the sandwich panel that are known from the literature.

  15. Elisa Studio showroom = Elisa Studio showroom / Jan Joonas Graps ; kommenteerinud Tiina Kuusisto

    Index Scriptorium Estoniae

    Graps, Jan Joonas, 1972-

    2015-01-01

    Elisa Studio showroom Helsingis Lasiplatsi, Mannerheimintie 22-24. Sisekujunduse autorid Jan Joonas Graps, Ken-Kristjan Ruut, Anne Määrmann (JanKen Wisespace). Lühidalt loovstuudiost JanKen Wisespace

  16. Fracture Behaviours in Compression-loaded Triangular Corrugated Core Sandwich Panels

    Directory of Open Access Journals (Sweden)

    Zaid N.Z.M.

    2016-01-01

    Full Text Available The failure modes occurring in sandwich panels based on the corrugations of aluminium alloy, carbon fibre-reinforced plastic (CFRP and glass fibre-reinforced plastic (GFRP are analysed in this work. The fracture behaviour of these sandwich panels under compressive stresses is determined through a series of uniform lateral compression performed on samples with different cell wall thicknesses. Compression test on the corrugated-core sandwich panels were conducted using an Instron series 4505 testing machine. The post-failure examinations of the corrugated-core in different cell wall thickness were conducted using optical microscope. Load-displacement graphs of aluminium alloy, GFRP and CFRP specimens were plotted to show progressive damage development with five unit cells. Four modes of failure were described in the results: buckling, hinges, delamination and debonding. Each of these failure modes may dominate under different cell wall thickness or loading condition, and they may act in combination. The results indicate that thicker composites corrugated-core panels tend can recover more stress and retain more stiffness. This analysis provides a valuable insight into the mechanical behaviour of corrugated-core sandwich panels for use in lightweight engineering applications.

  17. Energy absorption capabilities of composite sandwich panels under blast loads

    Science.gov (United States)

    Sankar Ray, Tirtha

    As blast threats on military and civilian structures continue to be a significant concern, there remains a need for improved design strategies to increase blast resistance capabilities. The approach to blast resistance proposed here is focused on dissipating the high levels of pressure induced during a blast through maximizing the potential for energy absorption of composite sandwich panels, which are a competitive structural member type due to the inherent energy absorption capabilities of fiber reinforced polymer (FRP) composites. Furthermore, the middle core in the sandwich panels can be designed as a sacrificial layer allowing for a significant amount of deformation or progressive failure to maximize the potential for energy absorption. The research here is aimed at the optimization of composite sandwich panels for blast mitigation via energy absorption mechanisms. The energy absorption mechanisms considered include absorbed strain energy due to inelastic deformation as well as energy dissipation through progressive failure of the core of the sandwich panels. The methods employed in the research consist of a combination of experimentally-validated finite element analysis (FEA) and the derivation and use of a simplified analytical model. The key components of the scope of work then includes: establishment of quantified energy absorption criteria, validation of the selected FE modeling techniques, development of the simplified analytical model, investigation of influential core architectures and geometric parameters, and investigation of influential material properties. For the parameters that are identified as being most-influential, recommended values for these parameters are suggested in conceptual terms that are conducive to designing composite sandwich panels for various blast threats. Based on reviewing the energy response characteristic of the panel under blast loading, a non-dimensional parameter AET/ ET (absorbed energy, AET, normalized by total energy

  18. Microcapillary blood sampling for serological examinations by radioimmunoassay (RIA) and enzyme immunoassay (ELISA)

    Energy Technology Data Exchange (ETDEWEB)

    Rodak, L; Smid, B; Valicek, L; Jurak, E [Vyzkumny Ustav Veterinarniho Lekarstvi, Brno-Medlanky (Czechoslovakia)

    1984-01-01

    Methods were tested of sampling blood and blood serum for serological examinations on filtration paper and into heparinized glass capillaries with transfer into the dilution solution of the given composition. Samples were also examined for ACH virus antibodies. The suitability of the sampling was verified by an examination of samples using ELISA and RIA methods. The results showed the suitability of sampling using microcapillaries. The titres of virus antibodies found using the ELISA and RIA methods were identical and the sensitivity of antibody detection was not reduced even after the sample had been stored for 60 days at a temperature of 20 degC.

  19. Microcapillary blood sampling for serological examinations by radioimmunoassay (RIA) and enzyme immunoassay (ELISA)

    International Nuclear Information System (INIS)

    Rodak, L.; Smid, B.; Valicek, L.; Jurak, E.

    1984-01-01

    Methods were tested of sampling blood and blood serum for serological examinations on filtration paper and into heparinized glass capillaries with transfer into the dilution solution of the given composition. Samples were also examined for ACH virus antibodies. The suitability of the sampling was verified by an examination of samples usiOg ELISA and RIA methods. The results showed the suitability of sampling using microcapillaries. The titres of virus antibodies found using the ELISA and RIA methods were identical and the sensitivity of antibody detection was not reduced even after the sample had been stored for 60 days at a temperature of 20 degC. (B.S.)

  20. Galactic binaries with eLISA

    OpenAIRE

    Nelemans, G.

    2013-01-01

    I review what eLISA will see from Galactic binaries -- double stars with orbital periods less than a few hours and white dwarf (or neutron star/black hole) components. I discuss the currently known binaries that are guaranteed (or verification) sources and explain why the expected total number of eLISA Galactic binaries is several thousand, even though there are large uncertainties in our knowledge of this population, in particular that of the interacting AM CVn systems. I very briefly sketch...

  1. Nanoparticle-based sandwich electrochemical immunoassay for carbohydrate antigen 125 with signal enhancement using enzyme-coated nanometer-sized enzyme-doped silica beads.

    Science.gov (United States)

    Tang, Dianping; Su, Biling; Tang, Juan; Ren, Jingjing; Chen, Guonan

    2010-02-15

    A novel nanoparticle-based electrochemical immunoassay of carbohydrate antigen 125 (CA125) as a model was designed to couple with a microfluidic strategy using anti-CA125-functionalized magnetic beads as immunosensing probes. To construct the immunoassay, thionine-horseradish peroxidase conjugation (TH-HRP) was initially doped into nanosilica particles using the reverse micelle method, and then HRP-labeled anti-CA125 antibodies (HRP-anti-CA125) were bound onto the surface of the synthesized nanoparticles, which were used as recognition elements. Different from conventional nanoparticle-based electrochemical immunoassays, the recognition elements of the immunoassay simultaneously contained electron mediator and enzyme labels and simplified the electrochemical measurement process. The sandwich-type immunoassay format was used for the online formation of the immunocomplex in an incubation cell and captured in the detection cell with an external magnet. The electrochemical signals derived from the carried HRP toward the reduction of H(2)O(2) using the doped thionine as electron mediator. Under optimal conditions, the electrochemical immunoassay exhibited a wide working range from 0.1 to 450 U/mL with a detection limit of 0.1 U/mL CA125. The precision, reproducibility, and stability of the immunoassay were acceptable. The assay was evaluated for clinical serum samples, receiving in excellent accordance with results obtained from the standard enzyme-linked immunosorbent assay (ELISA) method. Concluding, the nanoparticle-based assay format provides a promising approach in clinical application and thus represents a versatile detection method.

  2. Vibration and Acoustic Response of Rectangular Sandwich Plate under Thermal Environment

    Directory of Open Access Journals (Sweden)

    Yuan Liu

    2013-01-01

    Full Text Available In this paper, we focus on the vibration and acoustic response of a rectangular sandwich plate which is subjected to a concentrated harmonic force under thermal environment. The critical buckling temperature is obtained to decide the thermal load. The natural frequencies and modes as well as dynamic responses are acquired by using the analytical formulations based on equivalent non-classical theory, in which the effects of shear deformation and rotational inertia are taken into account. The rise of thermal load decreases the natural frequencies and moves response peaks to the low-frequency range. The specific features of sandwich plates with different formations are discussed subsequently. As the thickness ratio of facing to core increases, the natural frequencies are enlarged, and the response peaks float to the high-frequency region. Raising the Young's modulus of the core can cause the similar trends. The accuracy of the theoretical method is verified by comparing its results with those computed by the FEM/BEM.

  3. Direct Competitive Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Kohl, Thomas O; Ascoli, Carl A

    2017-07-05

    The competitive enzyme-linked immunosorbent assay (ELISA) (cELISA; also called an inhibition ELISA) is designed so that purified antigen competes with antigen in the test sample for binding to an antibody that has been immobilized in microtiter plate wells. The same concept works if the immobilized molecule is antigen and the competing molecules are purified labeled antibody versus antibody in a test sample. Direct cELISAs incorporate labeled antigen or antibody, whereas indirect assay configurations use reporter-labeled secondary antibodies. The cELISA is very useful for determining the concentration of small-molecule antigens in complex sample mixtures. In the direct cELISA, antigen-specific capture antibody is adsorbed onto the microtiter plate before incubation with either known standards or unknown test samples. Enzyme-linked antigen (i.e., labeled antigen) is also added, which can bind to the capture antibody only when the antibody's binding site is not occupied by either the antigen standard or antigen in the test samples. Unbound labeled and unlabeled antigens are washed away and substrate is added. The amount of antigen in the standard or the test sample determines the amount of reporter-labeled antigen bound to antibody, yielding a signal that is inversely proportional to antigen concentration within the sample. Thus, the higher the antigen concentration in the test sample, the less labeled antigen is bound to the capture antibody, and hence the weaker is the resultant signal. © 2017 Cold Spring Harbor Laboratory Press.

  4. Finite element method calculations of GMI in thin films and sandwiched structures: Size and edge effects

    International Nuclear Information System (INIS)

    Garcia-Arribas, A.; Barandiaran, J.M.; Cos, D. de

    2008-01-01

    The impedance values of magnetic thin films and magnetic/conductor/magnetic sandwiched structures with different widths are computed using the finite element method (FEM). The giant magneto-impedance (GMI) is calculated from the difference of the impedance values obtained with high and low permeability of the magnetic material. The results depend considerably on the width of the sample, demonstrating that edge effects are decisive for the GMI performance. It is shown that, besides the usual skin effect that is responsible for GMI, an 'unexpected' increase of the current density takes place at the lateral edge of the sample. In magnetic thin films this effect is dominant when the permeability is low. In the trilayers, it is combined with the lack of shielding of the central conductor at the edge. The resulting effects on GMI are shown to be large for both kinds of samples. The conclusions of this study are of great importance for the successful design of miniaturized GMI devices

  5. Gravity sag of sandwich panel assemblies as applied to precision cathode strip chamber structural design

    International Nuclear Information System (INIS)

    Horvath, J.

    1993-01-01

    The relationship between gravity sag of a precision cathode strip chamber and its sandwich panel structural design is explored parametrically. An algorithm for estimating the dominant component of gravity sag is defined. Graphs of normalized gravity sag as a function of gap frame width and material, sandwich core edge filler width and material, panel skin thickness, gap height, and support location are calculated using the gravity sag algorithm. The structural importance of the sandwich-to-sandwich ''gap frame'' connection is explained

  6. Functional grading of metal foam cores for yield-limited lightweight sandwich beams

    International Nuclear Information System (INIS)

    Conde, Yves; Pollien, Arnaud; Mortensen, Andreas

    2006-01-01

    We show that grading the porosity in a bent metal skin/metal foam core sandwich can generate significant weight savings in yield-limited design when, and only when, there is a gradient in the applied moment along the sandwich beam

  7. Behaviour of glued fibre composite sandwich structure in flexure: Experiment and Fibre Model Analysis

    International Nuclear Information System (INIS)

    Manalo, Allan; Aravinthan, Thiru

    2012-01-01

    Highlights: ► Fibre Model Analysis is used to examine the flexural behaviour of sandwich beams. ► Theoretical prediction using FMA is in good agreement with the experiment. ► Using the constituent materials in FMA predicted accurately the beam’s behaviour. ► FMA can be used for analysing sandwich beams with high-strength core in flexure. -- Abstract: The behaviour of glued composite sandwich beams in flexure was investigated with a view of using this material for structural and civil engineering applications. The building block of this glue-laminated beam is a new generation composite sandwich structure made up of glass fibre reinforced polymer skins and a high strength phenolic core material. A simplified Fibre Model Analysis (FMA) usually used to analyse a concrete beam section is adopted to theoretically describe the flexural behaviour of the innovative sandwich beam structure. The analysis included the flexural behaviour of the glued sandwich beams in the flatwise and the edgewise positions. The FMA accounted for the non-linear behaviour of the phenolic core in compression, the cracking of the core in tension and the linear elastic behaviour of the fibre composite skin. The results of the FMA showed a good agreement with the experimental data showing the efficiency and practical applications of the simplified FMA in analysing and designing sandwich structures with high strength core material.

  8. Research on Effective Electric-Mechanical Coupling Coefficient of Sandwich Type Piezoelectric Ultrasonic Transducer Using Bending Vibration Mode

    Directory of Open Access Journals (Sweden)

    Qiang Zhang

    2015-01-01

    Full Text Available An analytical model on electromechanical coupling coefficient and the length optimization of a bending piezoelectric ultrasonic transducer are proposed. The piezoelectric transducer consists of 8 PZT elements sandwiched between four thin electrodes, and the PZT elements are clamped by a screwed connection between fore beam and back beam. Firstly, bending vibration model of the piezoelectric transducer is built based on the Timoshenko beam theory. Secondly, the analytical model of effective electromechanical coupling coefficient is built based on the bending vibration model. Energy method and electromechanical equivalent circuit method are involved in the modelling process. To validate the analytical model, sandwich type piezoelectric transducer example in second order bending vibration mode is analysed. Effective electromechanical coupling coefficient of the transducer is optimized with simplex reflection technique, and the optimized ratio of length of the transducers is obtained. Finally, experimental prototypes of the sandwich type piezoelectric transducers are fabricated. Bending vibration mode and impedance of the experimental prototypes are tested, and electromechanical coupling coefficient is obtained according to the testing results. Results show that the analytical model is in good agreement with the experimental model.

  9. High renewable content sandwich structures based on flax-basalt hybrids and biobased epoxy polymers

    Science.gov (United States)

    Colomina, S.; Boronat, T.; Fenollar, O.; Sánchez-Nacher, L.; Balart, R.

    2014-05-01

    In the last years, a growing interest in the development of high environmental efficiency materials has been detected and this situation is more accentuated in the field of polymers and polymer composites. In this work, green composite sandwich structures with high renewable content have been developed with core cork materials. The base resin for composites was a biobased epoxy resin derived from epoxidized vegetable oils. Hybrid basalt-flax fabrics have been used as reinforcements for composites and the influence of the stacking sequence has been evaluated in order to optimize the appropriate laminate structure for the sandwich bases. Core cork materials with different thickness have been used to evaluate performance of sandwich structures thus leading to high renewable content composite sandwich structures. Results show that position of basalt fabrics plays a key role in flexural fracture of sandwich structures due to differences in stiffness between flax and basalt fibers.

  10. Combined-load buckling behavior of metal-matrix composite sandwich panels under different thermal environments

    Science.gov (United States)

    Ko, William L.; Jackson, Raymond H.

    1991-01-01

    Combined compressive and shear buckling analysis was conducted on flat rectangular sandwich panels with the consideration of transverse shear effects of the core. The sandwich panel is fabricated with titanium honeycomb core and laminated metal matrix composite face sheets. The results show that the square panel has the highest combined load buckling strength, and that the buckling strength decreases sharply with the increases of both temperature and panel aspect ratio. The effect of layup (fiber orientation) on the buckling strength of the panels was studied in detail. The metal matrix composite sandwich panel was much more efficient than the sandwich panel with nonreinforced face sheets and had the same specific weight.

  11. ELISA indireto para detecção de IgG antivírus da doença de Newcastle em soro de codorna Indirect ELISA for the detection of IgG specific to Newcastle disease virus in quail serum

    Directory of Open Access Journals (Sweden)

    D.D. Oliveira

    2007-10-01

    Full Text Available An indirect ELISA for the detection of japanese quail IgG specific to Newcastle disease virus (NDV was developed. The secondary anti-quail IgG was produced in Balb/c mice, by inoculating Freund's complete adjuvant emulsified japanese quail-IgG extract. The purification of IgG was achieved using the caprilic acid method. The ELISA was compared to the haemagglutination-inhibition (HI test for antibodies to NDV. ELISA cut-off point was established through TG-ROC analysis. Total correlation was observed between the ELISA and the HI, being the ELISA efficient in the identification of positive and negative sera, with high sensitivity and specificity (100%. These results validate the use of the indirect ELISA as an alternative for the detection of NDV-specific IgG in japanese quail sera, with the advantage of high sensitivity and automation.

  12. The use of enzyme-linked immunosorbent assay systems for the serology and antigen detection in parvovirus, coronavirus and rotavirus infections in dogs in The Netherlands.

    NARCIS (Netherlands)

    G.F. Rimmelzwaan (Guus); J. Groen (Jan); H.F. Egberink (Herman); G.H.A. Borst (Gerrit); F.G.C.M. Uytdehaag (Fons); A.D.M.E. Osterhaus (Albert)

    1991-01-01

    textabstractComplex trapping blocking (CTB) enzyme-linked immunosorbent assays (ELISAs) and indirect ELISAs for the detection of antibodies to canine parvovirus (CPV), canine coronavirus (CCV) and rotavirus in sera of dogs were established. Double antibody sandwich ELISAs for the detection of CPV-,

  13. Identification of material properties of sandwich structure with piezoelectric patches

    Directory of Open Access Journals (Sweden)

    Zemčík R.

    2008-11-01

    Full Text Available The work focuses on light-weight sandwich structures made of carbon-epoxy skins and foam core which have unique bending stiffness compared to conventional materials. The skins are manufactured by vacuum autoclave technology from unidirectional prepregs and the sandwich is then glued together. The resulting material properties of the structure usually differ from those provided by manufacturer or even those obtained from experimental tests on separate materials, which makes computational models unreliable. Therefore, the properties are identified using the combination of experimental analysis of the sandwich with attached piezoelectric transducer and corresponding static and modal finite element analyses. Simple mathematical optimization with repetitive finite element solution is used. The model is then verified by transient analysis when the piezoelectric patch is excited by harmonic signals covering the first two eigen-frequencies and the induced oscillations are measured by laser sensor.

  14. Natural fabric sandwich laminate composites: development and ...

    Indian Academy of Sciences (India)

    3Department of Production Technology, MIT Campus, Anna University, Chennai 600044, India. MS received ... In this work, eco-friendly natural fabric sandwich laminate (NFSL) composites are formulated using ... and eco-friendly quality [22].

  15. Numerical Study on the Projectile Impact Resistance of Multi-Layer Sandwich Panels with Cellular Cores

    Directory of Open Access Journals (Sweden)

    Liming Chen

    Full Text Available Abstract The projectile impact resistance of sandwich panels with cellular cores with different layer numbers has been numerically investigated by perpendicular impact of rigid blunt projectile in ABAQUS/Explicit. These panels with corrugation, hexagonal honeycomb and pyramidal truss cores are impacted at velocities between 50 m/s and 202 m/s while the relative density ranges from 0.001 to 0.15 The effects of core configuration and layer number on projectile impact resistance of sandwich panels with cellular cores are studied. At low impact velocity, sandwich panels with cellular cores outperform the corresponding solid ones and non-montonicity between relative density and projectile resistance of sandwich panels is found and analyzed. Multiplying layer can reduce the maximum central deflection of back face sheet of the above three sandwich panels except pyramidal truss ones in high relative density. Hexagonal honeycomb sandwich panel is beneficial to increasing layer numbers in lowering the contact force and prolonging the interaction time. At high impact velocity, though corrugation and honeycomb sandwich panels are inferior to the equal-weighted solid panels, pyramidal truss ones with high relative density outperform the corresponding solid panels. Multiplying layer is not the desirable way to improve high-velocity projectile resistance.

  16. A materials selection procedure for sandwiched beams via parametric optimization with applications in automotive industry

    International Nuclear Information System (INIS)

    Aly, Mohamed F.; Hamza, Karim T.; Farag, Mahmoud M.

    2014-01-01

    Highlights: • Sandwich panels optimization model. • Sandwich panels design procedure. • Study of sandwich panels for automotive vehicle flooring. • Study of sandwich panels for truck cabin exterior. - Abstract: The future of automotive industry faces many challenges in meeting increasingly strict restrictions on emissions, energy usage and recyclability of components alongside the need to maintain cost competiveness. Weight reduction through innovative design of components and proper material selection can have profound impact towards attaining such goals since most of the lifecycle energy usage occurs during the operation phase of a vehicle. In electric and hybrid vehicles, weight reduction has another important effect of extending the electric mode driving range between stops or gasoline mode. This paper adopts parametric models for design optimization and material selection of sandwich panels with the objective of weight and cost minimization subject to structural integrity constraints such as strength, stiffness and buckling resistance. The proposed design procedure employs a pre-compiled library of candidate sandwich panel material combinations, for which optimization of the layered thicknesses is conducted and the best one is reported. Example demonstration studies from the automotive industry are presented for the replacement of Aluminum and Steel panels with polypropylene-filled sandwich panel alternatives

  17. A quantitative exposure model simulating human norovirus transmission during preparation of deli sandwiches.

    Science.gov (United States)

    Stals, Ambroos; Jacxsens, Liesbeth; Baert, Leen; Van Coillie, Els; Uyttendaele, Mieke

    2015-03-02

    Human noroviruses (HuNoVs) are a major cause of food borne gastroenteritis worldwide. They are often transmitted via infected and shedding food handlers manipulating foods such as deli sandwiches. The presented study aimed to simulate HuNoV transmission during the preparation of deli sandwiches in a sandwich bar. A quantitative exposure model was developed by combining the GoldSim® and @Risk® software packages. Input data were collected from scientific literature and from a two week observational study performed at two sandwich bars. The model included three food handlers working during a three hour shift on a shared working surface where deli sandwiches are prepared. The model consisted of three components. The first component simulated the preparation of the deli sandwiches and contained the HuNoV reservoirs, locations within the model allowing the accumulation of NoV and the working of intervention measures. The second component covered the contamination sources being (1) the initial HuNoV contaminated lettuce used on the sandwiches and (2) HuNoV originating from a shedding food handler. The third component included four possible intervention measures to reduce HuNoV transmission: hand and surface disinfection during preparation of the sandwiches, hand gloving and hand washing after a restroom visit. A single HuNoV shedding food handler could cause mean levels of 43±18, 81±37 and 18±7 HuNoV particles present on the deli sandwiches, hands and working surfaces, respectively. Introduction of contaminated lettuce as the only source of HuNoV resulted in the presence of 6.4±0.8 and 4.3±0.4 HuNoV on the food and hand reservoirs. The inclusion of hand and surface disinfection and hand gloving as a single intervention measure was not effective in the model as only marginal reductions of HuNoV levels were noticeable in the different reservoirs. High compliance of hand washing after a restroom visit did reduce HuNoV presence substantially on all reservoirs. The

  18. Aptamer-conjugated silver nanoparticles for electrochemical dual-aptamer-based sandwich detection of staphylococcus aureus.

    Science.gov (United States)

    Abbaspour, Abdolkarim; Norouz-Sarvestani, Fatemeh; Noori, Abolhassan; Soltani, Noushin

    2015-06-15

    Staphylococcus aureus (S. aureus) is one of the most important human pathogens and causes numerous illnesses. In this study, we report a sensitive and highly selective dual-aptamer-based sandwich immunosensor for the detection of S. aureus. In this bioassay system, a biotinylated primary anti-S.aureus aptamer was immobilized on streptavidin coated magnetic beads (MB), which serves as a capture probe. A secondary anti-S.aureus aptamer was conjugated to silver nanoparticles (Apt-AgNP) that sensitively reports the detection of the target. In the presence of target bacterium, an Apt/S.aureus/apt-AgNP sandwich complex is formed on the MB surface and the electrochemical signal of AgNPs followed through anodic stripping voltammetry. The proposed sandwich assay benefits from advantageous of a sandwich assay for increased specificity, MB as carriers of affinity ligands for solution-phase recognition and fast magnetic separation, AgNPs for signal amplification, and an electrochemical stripping voltammetry read-out as a simple and sensitive detection. The electrochemical immunosensor shows an extended dynamic range from 10 to 1×10(6) cfu/mL with a low detection limit of 1.0 cfu/mL (S/N=3). Furthermore, the possible interference of other analog bacteria was studied. To assess the general applicability of this sensor, we investigated the quantification of S. aureus in real water samples. The results were compared to the experimental results obtained from a plate counting method, which demonstrated an acceptable consistency. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Microchip ELISA coupled with cell phone to detect ovarian cancer HE4 biomarker in urine.

    Science.gov (United States)

    Wang, ShuQi; Akbas, Ragip; Demirci, Utkan

    2015-01-01

    Ovarian cancer is a leading cause of death from gynecologic cancers in the USA, and early diagnosis can potentially increase 5-year survival rate. Detection of biomarkers derived from hyperplasia of epithelial tissue by enzyme-linked immunosorbent assay (ELISA) proves to be a practical way of early diagnosis of ovarian cancer. However, ELISA is commonly performed in a laboratory setting, and it cannot be used in a clinical setting for on-site consultation. We have shown a microchip ELISA that detects HE4, an ovarian cancer biomarker, from urine using a cell phone integrated with a mobile application for imaging and data analysis. In microchip ELISA, HE4 from urine was first absorbed on the surface; the primary and secondary antibodies were subsequently anchored on the surface via immuno-reaction; and addition of substrate led to color development because of enzymatic labeling. The microchip after color development was imaged using a cell phone, and the color intensity was analyzed by an integrated mobile application. By comparing with an ELISA standard curve, the concentration of HE4 was reported on the cell phone screen. The presented microchip ELISA coupled with a cell phone is portable as opposed to traditional ELISA, and this method can facilitate the detection of ovarian cancer at the point-of-care (POC).

  20. Factors Influencing the Measurement of Plasma/Serum Surfactant Protein D Levels by ELISA

    OpenAIRE

    Bratcher, Preston E.; Gaggar, Amit

    2014-01-01

    BACKGROUND: Extensive variations in human surfactant protein D (SP-D) levels in circulation as measured by ELISA exist in the published literature. In order to determine the source of these variations, factors influencing the measurement by ELISA were explored. MATERIALS AND METHODS: Peripheral blood from healthy individuals was collected into various vacutainers during the same blood draw. Recombinant SP-D was diluted into different matrices and used for a standard curve. Samples were analyz...

  1. Magnet-assisted device-level alignment for the fabrication of membrane-sandwiched polydimethylsiloxane microfluidic devices

    International Nuclear Information System (INIS)

    Lu, J-C; Liao, W-H; Tung, Y-C

    2012-01-01

    Polydimethylsiloxane (PDMS) microfluidic device is one of the most essential techniques that advance microfluidics research in recent decades. PDMS is broadly exploited to construct microfluidic devices due to its unique and advantageous material properties. To realize more functionalities, PDMS microfluidic devices with multi-layer architectures, especially those with sandwiched membranes, have been developed for various applications. However, existing alignment methods for device fabrication are mainly based on manual observations, which are time consuming, inaccurate and inconsistent. This paper develops a magnet-assisted alignment method to enhance device-level alignment accuracy and precision without complicated fabrication processes. In the developed alignment method, magnets are embedded into PDMS layers at the corners of the device. The paired magnets are arranged in symmetric positions at each PDMS layer, and the magnetic attraction force automatically pulls the PDMS layers into the aligned position during assembly. This paper also applies the method to construct a practical microfluidic device, a tunable chaotic micromixer. The results demonstrate the successful operation of the device without failure, which suggests the accurate alignment and reliable bonding achieved by the method. Consequently, the fabrication method developed in this paper is promising to be exploited to construct various membrane-sandwiched PDMS microfluidic devices with more integrated functionalities to advance microfluidics research. (paper)

  2. Detection of HIV-1 p24 Gag in plasma by a nanoparticle-based bio-barcode-amplification method.

    Science.gov (United States)

    Kim, Eun-Young; Stanton, Jennifer; Korber, Bette T M; Krebs, Kendall; Bogdan, Derek; Kunstman, Kevin; Wu, Samuel; Phair, John P; Mirkin, Chad A; Wolinsky, Steven M

    2008-06-01

    Detection of HIV-1 in patients is limited by the sensitivity and selectivity of available tests. The nanotechnology-based bio-barcode-amplification method offers an innovative approach to detect specific HIV-1 antigens from diverse HIV-1 subtypes. We evaluated the efficacy of this protein-detection method in detecting HIV-1 in men enrolled in the Chicago component of the Multicenter AIDS Cohort Study (MACS). The method relies on magnetic microparticles with antibodies that specifically bind the HIV-1 p24 Gag protein and nanoparticles that are encoded with DNA and antibodies that can sandwich the target protein captured by the microparticle-bound antibodies. The aggregate sandwich structures are magnetically separated from solution, and treated to remove the conjugated barcode DNA. The DNA barcodes (hundreds per target) were identified by a nanoparticle-based detection method that does not rely on PCR. Of 112 plasma samples from HIV-1-infected subjects, 111 were positive for HIV-1 p24 Gag protein (range: 0.11-71.5 ng/ml of plasma) by the bio-barcode-amplification method. HIV-1 p24 Gag protein was detected in only 23 out of 112 men by the conventional ELISA. A total of 34 uninfected subjects were negative by both tests. Thus, the specificity of the bio-barcode-amplification method was 100% and the sensitivity 99%. The bio-barcode-amplification method detected HIV-1 p24 Gag protein in plasma from all study subjects with less than 200 CD4(+) T cells/microl of plasma (100%) and 19 out of 20 (95%) HIV-1-infected men who had less than 50 copies/ml of plasma of HIV-1 RNA. In a separate group of 60 diverse international isolates, representative of clades A, B, C and D and circulating recombinant forms CRF01_AE and CRF02_AG, the bio-barcode-amplification method identified the presence of virus correctly. The bio-barcode-amplification method was superior to the conventional ELISA assay for the detection of HIV-1 p24 Gag protein in plasma with a breadth of coverage for diverse

  3. Phospho-SMC1 in-Cell ELISA based Detection of Ataxia Telangiectasia

    Directory of Open Access Journals (Sweden)

    Majid Zaki dizaji

    2016-12-01

    Full Text Available BackgroundAtaxia telangiectasia (A-T is a common genetically inherited cause of early childhood-onset ataxia. The infrequency of this disease, vast phenotype variation, disorders with features similar to those of A-T, and lack of definite laboratory test, make diagnosis difficult.  In addition, there is no rapid reliable laboratory method for identifying A-T heterozygotes, who susceptible to ionizing radiation (IR, atherosclerosis, diabetes, and cancers. We used SMC1pSer966 (pSMC1 in-cell colorimetric ELISA to diagnosis and screen in A-T families.Materials and Methods: With informed consent, 2cc peripheral blood was collected from the 15 A-T patients, their parents, and 24 healthy controls with no family history of malignancy, diabetes, and atherosclerosis. Extracted peripheral blood mononuclear cells (PBMCs were cultured in poly-L-Lysine treated 96-well plate with density of 70,000 cells per well. SMC1 phosphorylation was evaluated with cell-based ELISA kit 1 hour after 5 Gy IR and the pSMC1data normalized with Glyceraldehyde-3-phosphate dehydrogenase (GAPDH.Results: SMC1 phosphorylation was significantly low in A-T`s PBMC (mean + standard deviation [SD]: 0.075 + 0.034 in comparison to carriers (mean + SD: 0.190 + 0.060 and healthy controls (mean + SD: 0.312 +0.081, but unluckily could only discriminate A-T patients (Area Under the Curve -receiver operating characteristic [AUC-ROC]: 1.00, 1.00-1.00. This method in spite of rapidness and simplicity showed poor imprecision (22.49% coefficient of variation [CV] for intraday imprecision.Conclusion: It seems pSMC1 assessment by in-cell ELISA can be used for detection of A-T patients, but it may not sensitive enough for identification of carriers. This ELISA test is very simple, rapid, and requires less than 2cc blood. Thus it may be proposed for the early differential diagnosis of A-T as an alternative method.

  4. Harmonic Differential Quadrature Analysis of Soft-Core Sandwich Panels under Locally Distributed Loads

    Directory of Open Access Journals (Sweden)

    Xinwei Wang

    2016-11-01

    Full Text Available Sandwich structures are widely used in practice and thus various engineering theories adopting simplifying assumptions are available. However, most engineering theories of beams, plates and shells cannot recover all stresses accurately through their constitutive equations. Therefore, the soft-core is directly modeled by two-dimensional (2D elasticity theory without any pre-assumption on the displacement field. The top and bottom faces act like the elastic supports on the top and bottom edges of the core. The differential equations of the 2D core are then solved by the harmonic differential quadrature method (HDQM. To circumvent the difficulties in dealing with the locally distributed load by point discrete methods such as the HDQM, a general and rigorous way is proposed to treat the locally distributed load. Detailed formulations are provided. The static behavior of sandwich panels under different locally distributed loads is investigated. For verification, results are compared with data obtained by ABAQUS with very fine meshes. A high degree of accuracy on both displacement and stress has been observed.

  5. Mechanical Property Evaluation of Palm/Glass Sandwiched Fiber Reinforced Polymer Composite in Comparison with few natural composites

    Science.gov (United States)

    Raja Dhas, J. Edwin; Pradeep, P.

    2017-10-01

    Natural fibers available plenty can be used as reinforcements in development of eco friendly polymer composites. The less utilized palm leaf stalk fibers sandwiched with artificial glass fibers was researched in this work to have a better reinforcement in preparing a green composite. The commercially available polyester resin blend with coconut shell filler in nano form was used as matrix to sandwich these composites. Naturally available Fibers of palm leaf stalk, coconut leaf stalk, raffia and oil palm were extracted and treated with potassium permanganate solution which enhances the properties. For experimentation four different plates were fabricated using these fibers adopting hand lay-up method. These sandwiched composite plates are further machined to obtain ASTM standards Specimens which are mechanically tested as per standards. Experimental results reveal that the alkali treated palm leaf stalk fiber based polymer composite shows appreciable results than the others. Hence the developed composite can be recommended for fabrication of automobile parts.

  6. A Simple ELISA Exercise for Undergraduate Biology.

    Science.gov (United States)

    Baker, William P.; Moore, Cathy R.

    Understanding of immunological techniques such as the Enzyme Linked Immuno Sorbent Assay (ELISA) is an important part of instructional units in human health, developmental biology, microbiology, and biotechnology. This paper describes a simple ELISA exercise for undergraduate biology that effectively simulates the technique using a paper model.…

  7. Specificity of Toxocara ELISA in tropical populations.

    Science.gov (United States)

    Lynch, N R; Wilkes, L K; Hodgen, A N; Turner, K J

    1988-05-01

    The diagnosis of human infection by Toxocara canis relies heavily upon serological tests, the specificity of which can be inadequate in regions of endemic helminthiasis. When different population groups of tropical Venezuela were evaluated using ELISA based upon Toxocara excretory-secretory antigen (TcESA), solid-phase adsorption of the sera with extracts of a wide variety of non-homologous parasites revealed the existence of significant cross-reactivity. This was effectively and conveniently overcome when the test sera were incubated in the presence of the soluble parasite extracts in a competitive inhibition ELISA. The mean reduction of ELISA values caused by pre-adsorption of the sera tested was 32.2%, and that caused by competitive inhibition was 42.3%, the effects of these two procedures being strongly correlated (r = 0.83). The magnitude of the reduction was inversely proportional to the actual ELISA value (r = -0.55), and ranged from a mean of 68.0% in sera from apparently healthy individuals of medium-high socio-economic level, down to 28.1% in heavily parasitized Amazon indians. Ascaris showed the greatest degree of cross-reactivity in these tests, although under conditions of competitive inhibition even sera with high levels of antibody against this parasite could be negative in Toxocara ELISA. Western blotting revealed a major 81,400 D component that was shared between Ascaris and TcESA. Our results indicate that the competitive inhibition of cross-reactivity by soluble non-homologous parasite extracts provides a convenient and economical means of increasing the specificity of ELISA for the determination of the seroprevalence of toxocariasis in tropical populations.

  8. Diagnosis of theileria equi infections in horses in the Azores using cELISA and nested PCR

    Science.gov (United States)

    Equine piroplasmosis is a tick-borne disease of equids that is often caused by the parasite Theileria equi. We applied competitive ELISA (cELISA) and nested PCR diagnostic methods to detect this parasite in horses by screening 162 samples from mainland Portugal where the parasite is endemic, and 143...

  9. Quantum mechanical design and structures of hexanuclear sandwich complex and its multidecker sandwich clusters (Li6)n([18]annulene)n+1 (n = 1-3).

    Science.gov (United States)

    Wang, Shu-Jian; Li, Ying; Wu, Di; Wang, Yin-Feng; Li, Zhi-Ru

    2012-09-13

    By means of density functional theory, a hexanuclear sandwich complex [18]annulene-Li6-[18]annulene which consists of a central Li6 hexagon ring and large face-capping ligands, [18]annulene, is designed and investigated. The large interaction energy and HOMO-LUMO gap suggest that this novel charge-separated complex is highly stable and may be experimentally synthesized. In addition, the stability found in the [18]annulene-Li6-[18]annulene complex extends to multidecker sandwich clusters (Li6)n([18]annulene)n+1 (n = 2-3). The energy gain upon addition of a [18]annulene-Li6 unit to (Li6)n-1([18]annulene)n is pretty large (96.97-98.22 kcal/mol), indicating that even larger multideckers will also be very stable. Similar to ferrocene, such a hexanuclear sandwich complex could be considered as a versatile building block to find potential applications in different areas of chemistry, such as nanoscience and material science.

  10. Size-dependent analysis of a sandwich curved nanobeam integrated with piezomagnetic face-sheets

    Directory of Open Access Journals (Sweden)

    Ashraf M. Zenkour

    Full Text Available The aim of this research is to develop nonlocal transient magneto-electro-elastic formulation of a sandwich curved nanobeam including a nano-core and two piezo-magnetic face-sheets subjected to transverse mechanical loads and applied electric and magnetic potentials rest on Pasternak’s foundation. Nonlocal magneto-electro-elastic relations and Hamilton’s principle are used for derivation of the governing equations of motion. The analytical solution based on Fourier solution is presented for a simply-supported sandwich curved nanobeam. The numerical results are presented to investigate influence of significant parameters such as nonlocal parameter, radius of curvature, applied electric and magnetic potentials and two parameters of Pasternak's foundation on the dynamic responses of sandwich curved nanobeam. Keywords: Sandwich curved nanobeam, Dynamic responses, Piezo-magnetic face-sheets, Pasternak’s foundation, Radius of curvature, Nonlocal parameter

  11. Modal analysis and acoustic transmission through offset-core honeycomb sandwich panels

    Science.gov (United States)

    Mathias, Adam Dustin

    The work presented in this thesis is motivated by an earlier research that showed that double, offset-core honeycomb sandwich panels increased thermal resistance and, hence, decreased heat transfer through the panels. This result lead to the hypothesis that these panels could be used for acoustic insulation. Using commercial finite element modeling software, COMSOL Multiphysics, the acoustical properties, specifically the transmission loss across a variety of offset-core honeycomb sandwich panels, is studied for the case of a plane acoustic wave impacting the panel at normal incidence. The transmission loss results are compared with those of single-core honeycomb panels with the same cell sizes. The fundamental frequencies of the panels are also computed in an attempt to better understand the vibrational modes of these particular sandwich-structured panels. To ensure that the finite element analysis software is adequate for the task at hand, two relevant benchmark problems are solved and compared with theory. Results from these benchmark results compared well to those obtained from theory. Transmission loss results from the offset-core honeycomb sandwich panels show increased transmission loss, especially for large cell honeycombs when compared to single-core honeycomb panels.

  12. Comparison of new ELISA method with established SDS-PAGE method for determination of muscle myosin heavy chain isoforms

    Czech Academy of Sciences Publication Activity Database

    Říčný, Jan; Soukup, Tomáš

    2011-01-01

    Roč. 60, č. 6 (2011), s. 899-904 ISSN 0862-8408 R&D Projects: GA ČR(CZ) GA304/08/0256 Grant - others:EC(XE) LSH-CT-2004-511978 Institutional research plan: CEZ:AV0Z50110509 Keywords : muscle fiber types * myosin heavy chains * SDS - PAGE * immunoreactions * thyroid hormones * ELISA Subject RIV: EA - Cell Biology Impact factor: 1.555, year: 2011

  13. Evaluation of two commercially available ELISA kits for the determination of melatonin concentrations in amniotic fluid throughout pregnancy.

    Science.gov (United States)

    Bagci, Soyhan; Altuntas, Özlem; Katzer, David; Berg, Christoph; Willruth, Arne; Reutter, Heiko; Bartmann, Peter; Müller, Andreas; Zur, Berndt

    2017-01-01

    Background The aim of the present study is to evaluate the utility of extraction versus non-extraction-based commercial melatonin ELISA kits for determining the melatonin concentration in amniotic fluid obtained in early and late pregnancy. Methods Pregnancy duration less than 28 weeks was defined as early and from 28 weeks until delivery as late gestation. Nine samples were obtained in early and 18 in late pregnancy. Two commercially available melatonin ELISA kits (melatonin ELISA RE54021, including methanol-based extraction and direct saliva melatonin ELISA RE 54041, not including an extraction step, both from IBL-International, Germany) were used to determine melatonin concentrations in amniotic fluid. Results The mean melatonin concentration in ELISAs assayed by the non-extraction was significantly lower than those assayed after extraction. Subgroup analysis showed that there was no significant difference between melatonin concentration measured by non-extraction versus extraction ELISA in early pregnancy (11.2 ± 7.4 vs. 12.2 ± 7.7, respectively, P = 0.463) but that the mean melatonin concentration in late pregnancy was significantly lower when assayed by non-extraction ELISA than when assayed by extraction ELISA (14.8 ± 9.3 vs. 145.1 ± 179.3, respectively; P pregnancy was rather poor (r 2  = 0.271, P = 0.022), as opposed to the good correlation found in early pregnancy (r 2  = 0.929, P melatonin assay without an extraction step, such as direct saliva ELISA, does not seem to be a valid method to determine the melatonin concentration of amniotic fluid, especially in late gestation.

  14. Comparação entre diversos antígenos para o diagnóstico de Anaplasma marginale por ELISA Comparison between several antigens for diagnosis of Anaplasma marginale by ELISA

    Directory of Open Access Journals (Sweden)

    Carlos A.N. Ramos

    2010-01-01

    Full Text Available Anaplasmose bovina é uma doença com grande importância nas regiões tropicais e subtropicais do mundo por determinar perdas econômicas devido à mortalidade e redução da produtividade. É causada por Anaplasma marginale, uma riquétsia intraeritrocítica obrigatória cujo controle requer, além de uma vacina eficiente, uma acurada identificação de bovinos cronicamente infectados. Apesar de existirem atualmente diversos métodos de diagnóstico dessa riquétsia, os métodos sorológicos, em particular o ensaio de imunoadsorção enzimática-ELISAs, são os mais utilizados devido à sua versatilidade e praticidade. No entanto, devido ao grande número de antígenos disponíveis, atualmente torna-se necessária uma avaliação para definir quais antígenos apresentam um melhor desempenho no diagnóstico da anaplasmose. Soros de bovinos positivos e negativos para A. marginale por PCR, e soros de animais provenientes do Brasil e Costa Rica, foram testados em ELISAs baseados em MSP1a, MSP2 e MSP5 recombinantes, um pool das três proteínas recombinantes, e antígeno de lisado de corpúsculos iniciais da riquétsia (CI. Utilizando soro de bovinos positivos para A. marginale por PCR, uma maior sensibilidade foi observada no ELISA CI. No entanto, uma maior especificidade, com soro de bovinos negativos a PCR, foi observada com os ELISAs recombinantes. O porcentual de bovinos positivos do Brasil e Costa Rica foi maior com ELISA CI. Razões para essas diferenças são discutidas.Bovine anaplasmosis is a major disease in tropical and subtropical regions of the world by determine economical loss due mortality and productive reduction. The disease is caused by Anaplasma marginale, an intraerythrocytic rickettsia whose control requires, besides an efficient vaccine, the accurate identification of chronically infected cattle. Although the existence of diverse methods of diagnosis of this rickettsia, the serological methods, in particular the enzyme

  15. Optimal locations of piezoelectric patches for supersonic flutter control of honeycomb sandwich panels, using the NSGA-II method

    International Nuclear Information System (INIS)

    Nezami, M; Gholami, B

    2016-01-01

    The active flutter control of supersonic sandwich panels with regular honeycomb interlayers under impact load excitation is studied using piezoelectric patches. A non-dominated sorting-based multi-objective evolutionary algorithm, called non-dominated sorting genetic algorithm II (NSGA-II) is suggested to find the optimal locations for different numbers of piezoelectric actuator/sensor pairs. Quasi-steady first order supersonic piston theory is employed to define aerodynamic loading and the p-method is applied to find the flutter bounds. Hamilton’s principle in conjunction with the generalized Fourier expansions and Galerkin method are used to develop the dynamical model of the structural systems in the state-space domain. The classical Runge–Kutta time integration algorithm is then used to calculate the open-loop aeroelastic response of the system. The maximum flutter velocity and minimum voltage applied to actuators are calculated according to the optimal locations of piezoelectric patches obtained using the NSGA-II and then the proportional feedback is used to actively suppress the closed loop system response. Finally the control effects, using the two different controllers, are compared. (paper)

  16. X-joints in composite sandwich panels

    NARCIS (Netherlands)

    Vredeveldt, A.W.; Janssen, G.Th.M.

    1998-01-01

    The small structural weight of fast large ships such as fast mono hulls or catamaran type of ships is of extreme importance to their success. One possible light weight structural solution is the sandwich panel with fibre reinforced laminates and a balsa, honeycomb or foam core. A severe obstacle for

  17. Friction stir welding (FSW of aluminium foam sandwich panels

    Directory of Open Access Journals (Sweden)

    M. Bušić

    2016-07-01

    Full Text Available The article focuses on the influence of welding speed and tool tilt angle upon the mechanical properties at the friction stir welding of aluminium foam sandwich panels. Double side welding was used for producing butt welds of aluminium sandwich panels applying insertion of extruded aluminium profile. Such insertion provided lower pressure of the tool upon the aluminium panels, providing also sufficient volume of the material required for the weldment formation. Ultimate tensile strength and flexural strength for three-point bending test have been determined for samples taken from the welded joints. Results have confirmed anticipated effects of independent variables.

  18. Three different signal amplification strategies for the impedimetric sandwich detection of thrombin

    Energy Technology Data Exchange (ETDEWEB)

    Ocaña, Cristina; Valle, Manel del, E-mail: manel.delvalle@uab.cat

    2016-03-17

    In this work, we report a comparative study on three highly specific amplification strategies for the ultrasensitive detection of thrombin with the use of aptamer sandwich protocol. The protocol consisted on the use of a first thrombin aptamer immobilized on the electrode surface, the recognition of thrombin protein, and the reaction with a second biotinylated thrombin aptamer forming the sandwich. Through the exposed biotin end, three variants have been tested to amplify the electrochemical impedance signal. The strategies included (a) silver enhancement treatment, (b) gold enhancement treatment and (c) insoluble product produced by the combination of the enzyme horseradish peroxidase (HRP) and 3-amino-9-ethylcarbazole (AEC). The properties of the sensing surface were probed by electrochemical impedance measurements in the presence of the ferrocyanide/ferricyanide redox marker. Insoluble product strategy and silver enhancement treatment resulted in the lowest detection limit (0.3 pM), while gold enhancement method resulted in the highest reproducibility, 8.8% RSD at the pM thrombin concentration levels. Results of silver and gold enhancement treatment also permitted direct inspection by scanning electron microscopy (SEM). - Highlights: • Aptasensor to detect thrombin reaching the femtomolar level. • Biosensing protocol employs two thrombin aptamers in a sandwich capture scheme. • Use of second biotinylated aptamer allows many amplification and detection variants. • Precipitation reaction provides the highest signal amplification of ca. 3 times. • Double recognition event improves remarkably selectivity for thrombin detection.

  19. Three different signal amplification strategies for the impedimetric sandwich detection of thrombin

    International Nuclear Information System (INIS)

    Ocaña, Cristina; Valle, Manel del

    2016-01-01

    In this work, we report a comparative study on three highly specific amplification strategies for the ultrasensitive detection of thrombin with the use of aptamer sandwich protocol. The protocol consisted on the use of a first thrombin aptamer immobilized on the electrode surface, the recognition of thrombin protein, and the reaction with a second biotinylated thrombin aptamer forming the sandwich. Through the exposed biotin end, three variants have been tested to amplify the electrochemical impedance signal. The strategies included (a) silver enhancement treatment, (b) gold enhancement treatment and (c) insoluble product produced by the combination of the enzyme horseradish peroxidase (HRP) and 3-amino-9-ethylcarbazole (AEC). The properties of the sensing surface were probed by electrochemical impedance measurements in the presence of the ferrocyanide/ferricyanide redox marker. Insoluble product strategy and silver enhancement treatment resulted in the lowest detection limit (0.3 pM), while gold enhancement method resulted in the highest reproducibility, 8.8% RSD at the pM thrombin concentration levels. Results of silver and gold enhancement treatment also permitted direct inspection by scanning electron microscopy (SEM). - Highlights: • Aptasensor to detect thrombin reaching the femtomolar level. • Biosensing protocol employs two thrombin aptamers in a sandwich capture scheme. • Use of second biotinylated aptamer allows many amplification and detection variants. • Precipitation reaction provides the highest signal amplification of ca. 3 times. • Double recognition event improves remarkably selectivity for thrombin detection.

  20. The Response of Clamped Shallow Sandwich Arches with Metallic Foam Cores to Projectile Impact Loading

    Directory of Open Access Journals (Sweden)

    Yanping Fan

    Full Text Available Abstract The dynamic response and energy absorption capabilities of clamped shallow sandwich arches with aluminum foam core were numerically investigated by impacting the arches at mid-span with metallic foam projectiles. The typical deformation modes, deflection response, and core compression of sandwich arches obtained from the tests were used to validate the computation model. The resistance to impact loading was quantified by the permanent transverse deflection at mid-span of the arches as a function of projectile momentum. The sandwich arches have a higher shock resistance than the monolithic arches of equal mass, and shock resistance could be significantly enhanced by optimizing geometrical configurations. Meanwhile, decreasing the face-sheet thickness and curvature radius could enhance the energy absorption capability of the sandwich arches. Finite element calculations indicated that the ratio of loading time to structural response time ranged from 0.1 to 0.4. The projectile momentum, which was solely used to quantify the structural response of sandwich arches, was insufficient. These findings could provide guidance in conducting further theoretical studies and producing the optimal design of metallic sandwich structures subjected to impact loading.

  1. Comparison of four HTLV-I and HTLV-I + II ELISAs

    NARCIS (Netherlands)

    Vrielink, H.; Reesink, H.; Habibuw, M.; Schuller, M.; van der Meer, C.; Lelie, P.

    1999-01-01

    BACKGROUND: Various countries require blood donor screening using assays applying specific HTLV-I and HTLV-II antigens. We evaluated the sensitivity and specificity of 4 anti-HTLV-I + II ELISAs (Abbott, Murex, Organon Teknika and Ortho). METHODS: Panel A consisted of HTLV-I-positive individuals (n =

  2. Generation of Elliptically Polarized Terahertz Waves from Antiferromagnetic Sandwiched Structure.

    Science.gov (United States)

    Zhou, Sheng; Zhang, Qiang; Fu, Shu-Fang; Wang, Xuan-Zhang; Song, Yu-Ling; Wang, Xiang-Guang; Qu, Xiu-Rong

    2018-04-01

    The generation of elliptically polarized electromagnetic wave of an antiferromagnetic (AF)/dielectric sandwiched structure in the terahertz range is studied. The frequency and external magnetic field can change the AF optical response, resulting in the generation of elliptical polarization. An especially useful geometry with high levels of the generation of elliptical polarization is found in the case where an incident electromagnetic wave perpendicularly illuminates the sandwiched structure, the AF anisotropy axis is vertical to the wave-vector and the external magnetic field is pointed along the wave-vector. In numerical calculations, the AF layer is FeF2 and the dielectric layers are ZnF2. Although the effect originates from the AF layer, it can be also influenced by the sandwiched structure. We found that the ZnF2/FeF2/ZnF2 structure possesses optimal rotation of the principal axis and ellipticity, which can reach up to about thrice that of a single FeF2 layer.

  3. Assessment of foam fracture in sandwich beams using thermoelastic stress analysis

    DEFF Research Database (Denmark)

    Dulieu-Barton, J.M.; Berggreen, Christian; Mettemberg, C.

    2009-01-01

    Thermoelastic Stress Analysis (TSA) has been well established for determining crack-tip parameters in metallic materials. This paper examines its ability to determine accurately the crack-tip parameters for PVC foam used in sandwich structures.......Thermoelastic Stress Analysis (TSA) has been well established for determining crack-tip parameters in metallic materials. This paper examines its ability to determine accurately the crack-tip parameters for PVC foam used in sandwich structures....

  4. Influence of baking time and matrix effects on the detection of milk allergens in cookie model food system by ELISA.

    Science.gov (United States)

    Monaci, Linda; Brohée, Marcel; Tregoat, Virginie; van Hengel, Arjon

    2011-07-15

    Milk allergens are common allergens occurring in foods, therefore raising concern in allergic consumers. Enzyme-linked immunosorbent assay (ELISA) is, to date, the method of choice for the detection of food allergens by the food industry although, the performance of ELISA might be compromised when severe food processing techniques are applied to allergen-containing foods. In this paper we investigated the influence of baking time on the detection of milk allergens by using commercial ELISA kits. Baked cookies were chosen as a model food system and experiments were set up to study the impact of spiking a matrix food either before, or after the baking process. Results revealed clear analytical differences between both spiking methods, which stress the importance of choosing appropriate spiking methodologies for method validation purposes. Finally, since the narrow dynamic range of quantification of ELISA implies that dilution of samples is required, the impact of sample dilution on the quantitative results was investigated. All parameters investigated were shown to impact milk allergen detection by means of ELISA. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Effects of thermal processing on the enzyme-linked immunosorbent assay (ELISA) detection of milk residues in a model food matrix.

    Science.gov (United States)

    Downs, Melanie L; Taylor, Steve L

    2010-09-22

    Food products and ingredients are frequently tested for the presence of undeclared allergenic food residues (including milk) using commercial enzyme-linked immunosorbent assays (ELISAs). However, little is understood about the efficacy of these kits with thermally processed foods. This study evaluated the performance of three milk ELISA kits with a model food processed by several methods. A model food (pastry dough squares) was spiked with nonfat dry milk at several concentrations. The pastry squares were processed by boiling (100 °C for 2 min), baking (190 °C for 30 min), frying (190 °C for 2 min), and retorting (121 °C for 20 min with 17 psi overpressure). Samples were analyzed with three commercial ELISA kits: Neogen Veratox Total Milk, ELISA Systems β-lactoglobulin, and ELISA Systems casein. The detection of milk residues depended upon the type of processing applied to the food and the specific milk analyte targeted by the ELISA kit. Poor recoveries were obtained in all processed samples (2-10% of expected values) using the β-lactoglobulin kit. Better recoveries were obtained in boiled samples (44 and 59%, respectively) using the total milk and casein kits. However, these kits performed poorly with baked (9 and 21%) and fried (7 and 18%) samples. Moderate recoveries were observed in retorted samples (23 and 28%). The decreased detection in processed samples is likely due to protein modifications, including aggregation and Maillard reactions, which affect the solubility and immunoreactivity of the antigens detected by the ELISA methods. The observed decreases in ELISA detection of milk are dramatic enough to affect risk-assessment decisions. However, a lower detection of milk residues does not necessarily indicate decreased allergenicity. These ELISA kits are not acceptable for all applications, and users should understand the strengths and limitations of each method.

  6. An Evidence-Based Approach to Detection by DASI-ELISA and RT-PCR in Dormant Period

    Directory of Open Access Journals (Sweden)

    Antonio Olmos

    2008-01-01

    Full Text Available An evidence-based approach, such as those developed in clinical and veterinary medicine, was applied to the detection of Plum pox virus (PPV during the dormant period. A standardized methodology was used for the calculation of parameters of the operational capacity of DASI-ELISA and RT-PCR in wintertime. These methods are routinely handled to test the sanitary status of plants in national or international trading and in those cases concerning export-import of plant materials. Diagnosis often has to be performed during the dormant period, when plant material is commercialized. Some guidelines to interpret diagnostic results of wintertime are provided in an attempt to minimize risks associated with the methods and over-reliance on the binary outcome of a single assay. In order to evaluate if a complementary test increased the confidence of PPV diagnosis when discordant results between DASI-ELISA and RT-PCR are obtained, NASBA-FH also was included. Likelihood ratios of each method were estimated based on the sensitivity and specificity obtained in wintertime. Subsequently, a Bayesian approach was performed to calculate post-test probability of PPV infection in spring. Results of evidence-based approach show that different PPV prevalences require different screening tests. Thus, at very low PPV prevalence levels DASI-ELISA should be used as the election method, whilst at the highest PPV prevalence levels RT-PCR should be performed. NASBA-FH could be used at medium prevalences to clarify discordances between DASI-ELISA and RT-PCR.

  7. Efficacy demonstration of tetanus vaccines by double antigen ELISA.

    Science.gov (United States)

    Rosskopf, U; Noeske, K; Werner, E

    2005-09-01

    This paper describes a double antigen ELISA (DAE) for rapid, specific and reliable assessment of the antitetanus immune status of horses and sheep. Compared with the indirect ELISA, the double antigen ELISA has the advantage of species-independent testing of sera. Thanks to its test design, it is more specific since the detected antibodies are forced to bind tetanus toxoid twice. In addition, it is very sensitive to tetanus antibodies, enabling the detection of low antibody titres, in range which is relevant for the assessment of the protective status (tetanus toxin neutralising antibodies). The detection limit of the DAE for tetanus antibodies is in the order of 10(-4) EU/ml. A comparison of in vitro results of individual sera with in vivo titres showed that horse sera with titres of 0.04 and 0.05 EU/ml in the DAE showed titres of > 0.05 IU and 0.034 IU/ml respectively during in vivo testing thus indicating good agreement. For tested sheep sera which were rated > 0.05 IU/ml in vivo, the corresponding titre in the DAE was 0.24 EU/ml. Clear tetanus antitoxin establishment of protective ELISA limits requires further comparative examination of sera with low titres (tetanus vaccines ad us. vet. As a consequence, the toxin neutralisation test (still being the standard method of choice for quantifying tetanus toxin neutralising antitoxin titres) could be replaced, since it requires too great a number of animals per test and involves considerable suffering for the animals. The test described here reduces the use of mice and guinea pigs within vaccine efficacy testing. In addition, it involves less exposure of the laboratory personnel to toxin.

  8. AA, sandwich line with magnetic horn

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    Continuation from 8010293: Finally, the sandwich line with the horn is placed on the ground, for the horn to be inspected and, if needed, exchanged for a new one. The whole procedure was trained with several members of the AA team, for quick and safe handling, and to share the radiation dose amongst them.

  9. Properties of polyurethane foam/coconut coir fiber as a core material and as a sandwich composites component

    Science.gov (United States)

    Azmi, M. A.; Abdullah, H. Z.; Idris, M. I.

    2013-12-01

    This research focuses on the fabrication and characterization of sandwich composite panels using glass fiber composite skin and polyurethane foam reinforced coconut coir fiber core. The main objectives are to characterize the physical and mechanical properties and to elucidate the effect of coconut coir fibers in polyurethane foam cores and sandwich composite panels. Coconut coir fibers were used as reinforcement in polyurethane foams in which later were applied as the core in sandwich composites ranged from 5 wt% to 20 wt%. The physical and mechanical properties found to be significant at 5 wt% coconut coir fiber in polyurethane foam cores as well as in sandwich composites. It was found that composites properties serve better in sandwich composites construction.

  10. Properties of polyurethane foam/coconut coir fiber as a core material and as a sandwich composites component

    International Nuclear Information System (INIS)

    Azmi, M A; Abdullah, H Z; Idris, M I

    2013-01-01

    This research focuses on the fabrication and characterization of sandwich composite panels using glass fiber composite skin and polyurethane foam reinforced coconut coir fiber core. The main objectives are to characterize the physical and mechanical properties and to elucidate the effect of coconut coir fibers in polyurethane foam cores and sandwich composite panels. Coconut coir fibers were used as reinforcement in polyurethane foams in which later were applied as the core in sandwich composites ranged from 5 wt% to 20 wt%. The physical and mechanical properties found to be significant at 5 wt% coconut coir fiber in polyurethane foam cores as well as in sandwich composites. It was found that composites properties serve better in sandwich composites construction

  11. Sandwich Hologram Interferometry For Determination Of Sacroiliac Joint Movements

    Science.gov (United States)

    Vukicevic, S.; Vinter, I.; Vukicevic, D.

    1983-12-01

    Investigations were carried out on embalmed and fresh specimens of human pelvisis with preserved lumbar spines, hip joints and all the ligaments. Specimens were tested under static vertical loading by pulsed laser interferometry. The deformations and behaviour of particular pelvic parts were interpreted by providing computer interferogram models. Results indicate rotation and tilting of the sacrum in the dorso-ventral direction and small but significant movements in the cranio-caudal direction. Sandwich holography proved to be the only applicable method when there is a combination of translation and tilt in the range of 200 μm to 1.5 mm.

  12. Biomimetic ELISA detection of malachite green based on magnetic molecularly imprinted polymers.

    Science.gov (United States)

    Li, Lu; Lin, Zheng-Zhong; Peng, Ai-Hong; Zhong, Hui-Ping; Chen, Xiao-Mei; Huang, Zhi-Yong

    2016-11-01

    A direct competitive enzyme-linked immunosorbent assay (ELISA) method was used for the detection of malachite green (MG) with a high sensitivity and selectivity using magnetic molecularly imprinted polymers (MMIPs) as a bionic antibody. MMIPs were prepared through emulsion polymerization using Fe 3 O 4 nanoparticles as magnetic nuclei, MG as a template, methacrylic acid (MAA) as a functional monomer, ethylene glycol dimethacrylate (EGDMA) as a crosslinking agent and span-80/tween-80 as mixed emulsifiers. The MMIPs were characterized by scanning electron micrographs (SEM), thermal-gravimetric analyzer (TGA), Fourier transform infrared spectrometer (FT-IR) and vibrating sample magnetometer (VSM), respectively. A high magnetic saturation value of 54.1emug -1 was obtained, resulting in rapid magnetic separation of MMIPs with an external magnet. The IC 50 of the established ELISA method was 20.1μgL -1 and the detection limit (based on IC 85 ) was 0.1μgL -1 . The MMIPs exhibited high selective binding capacity for MG with cross-reactivities less than 3.9% for MG structural analogues. The MG spiking recoveries were 85.0%-106% with the relative standard deviations less than 4.7%. The results showed that the biomimetic ELISA method by using MMIPs as bionic antibody could be used to detect MG rapidly in fish samples with a high sensitivity and accuracy. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Self-healing sandwich structures incorporating an interfacial layer with vascular network

    International Nuclear Information System (INIS)

    Chen, Chunlin; Peters, Kara; Li, Yulong

    2013-01-01

    A self-healing capability specifically targeted for sandwich composite laminates based on interfacial layers with built-in vascular networks is presented. The self-healing occurs at the facesheet–core interface through an additional interfacial layer to seal facesheet cracks and rebond facesheet–core regions. The efficacy of introducing the self-healing system at the facesheet–core interface is evaluated through four-point bend and edgewise compression testing of representative foam core sandwich composite specimens with impact induced damage. The self-healing interfacial layer partially restored the specific initial stiffness, doubling the residual initial stiffness as compared to the control specimen after the impact event. The restoration of the ultimate specific skin strength was less successful. The results also highlight the critical challenge in self-healing of sandwich composites, which is to rebond facesheets which have separated from the core material. (paper)

  14. A numerical simulation of metallic cylindrical sandwich shells subjected to air blast loading

    Directory of Open Access Journals (Sweden)

    Lin Jing

    Full Text Available The dynamic response of cylindrical sandwich shells with aluminum foam cores subjected to air blast loading was investigated numerically in this paper. According to KNR theory, the nonlinear compressibility of the air and finite shock conditions were taken into account in the finite element model. Numerical simulation results show that the compression strain, which plays a key role on energy absorption, increases approximately linearly with normalized impulse, and reduces with increasing relative density or the ratio of face-sheet thickness and core thickness. An increase of the impulse will delay the equalization of top and bottom face-sheet velocities of sandwich shell, but there is a maximum value in the studied bound. A limited study of weight optimization was carried out for sandwich shells with respect to the respective geometric parameters, including face-sheet thickness, core thickness and core relative density. These numerical results are of worth to theoretical prediction and engineering application of cellular metal sandwich structures.

  15. DETECTION OF HUMAN BLOODSTAINS BY ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA

    Directory of Open Access Journals (Sweden)

    GHOLAM-HOSSEIN EDRISSIAN

    1982-07-01

    Full Text Available The microplate method of e nzyme-l i nke d i rnmuno s o r be n t a s s ay (ELISA , usi ng alkaline phosphatase anti-human I gG conj ugate , was modified and appl ied in t he dete c t i on of the human b lood specimens among the blood samples prep a r ed fr om human and laborat or y anima l s i n t he form of small dr ied b loodst a i ns on f ilt e r paper . The modi f i e d ELISA t e chnique wa s compa red wit h t he agar double d i f f us ion me t hod of prec ipitin test ."nThe results of this primary study showed t ha t the ELISA i n compare to gel diffusi o n t e st is sensitive and specific. It is also enough repr oducible and practical t o be consider as a competent technique for i de nt i f i c ation o f human bloodstains in medicolegal laboratories .

  16. Evaluation of SD BIOLINE H. pylori Ag rapid test against double ELISA with SD H. pylori Ag ELISA and EZ-STEP H. pylori Ag ELISA tests.

    Science.gov (United States)

    Negash, Markos; Kassu, Afework; Amare, Bemnet; Yismaw, Gizachew; Moges, Beyene

    2018-01-01

    Helicobacter pylori antibody titters fall very slowly even after successful treatment. Therefore, tests detecting H. pylori antibody lack specificity and sensitivity. On the other hand, H. pylori stool antigen tests are reported as an alternative assay because of their reliability and simplicity. However, the comparative performance of H. pylori stool antigen tests for detecting the presence of the bacterium in clinical specimens in the study area is not assessed. Therefore, in this study we evaluated the performance of SD BIOLINE H. pylori Ag rapid test with reference to the commercially available EZ- STEP ELISA and SD BIOLINE H. pylori Ag ELISA tests. Stool samples were collected to analyse the diagnostic performance of SD BIOLINE H. pylori Ag rapid test kit using SD H. pylori Ag ELISA kit and EZ- STEP ELISA tests as a gold standard. Serum samples were also collected from each patient to test for the presence of H. pylori antibodies using dBest H. pylori Test Disk. Sensitivity, specificity, predictive values and kappa value are assessed. P values H. pylori Ag rapid test were: 95.6% (95% CI, 88.8-98.8), 92.5% (95%CI, 89-94.1%), 86.7% (95% CI, 80.5-89.6), and 97.6% (95% CI, 993.9-99.3) respectively. The performance of SD BIOLINE H. pylori Ag rapid test was better than the currently available antibody test in study area. Therefore, the SD BIOLINE Ag rapid stool test could replace and be used to diagnose active H. pylori infection before the commencement of therapy among dyspeptic patients.

  17. Impact damage detection in light composite sandwich panels using piezo-based nonlinear vibro-acoustic modulations

    International Nuclear Information System (INIS)

    Pieczonka, L; Ukowski, P; Klepka, A; Staszewski, W J; Uhl, T; Aymerich, F

    2014-01-01

    The nonlinear vibro-acoustic modulation technique is used for impact damage detection in light composite sandwich panels. The method utilizes piezo-based low-frequency vibration and high-frequency ultrasonic excitations. The work presented focuses on the analysis of modulation intensity. The results show that the method can be used for impact damage detection reliably separating damage-related from vibro-acoustic modulations from other intrinsic nonlinear modulations. (paper)

  18. Sensory Evaluation and Feasibility Report of Plantain Sandwich for Nigerian Market

    OpenAIRE

    Olu Malomo; E.O. Uche; E.A. Alamu

    2015-01-01

    Protein-energy malnutrition is a common nutritional disorder in developing countries and constitutes a major public health problem in young children and elderly people. This project is aimed at evaluating the acceptability of plantain-peanut sandwich and roasted at different temperatures. A plantain-peanut sandwich consists of minced protein stuffed into a carbohydrate source made into a roll as a food product. The plantain was roasted at two different temperatures than later enriched with 5%...

  19. Numerical analysis of sandwich beam with corrugated core under three-point bending

    Energy Technology Data Exchange (ETDEWEB)

    Wittenbeck, Leszek [Poznan University of Technology, Institute of Mathematics Piotrowo Street No. 5, 60-965 Poznan (Poland); Grygorowicz, Magdalena; Paczos, Piotr [Poznan University of Technology, Institute of Applied Mechanics Jana Pawla IIStreet No. 24, 60-965 Poznan (Poland)

    2015-03-10

    The strength problem of sandwich beam with corrugated core under three-point bending is presented.The beam are made of steel and formed by three mutually orthogonal corrugated layers. The finite element analysis (FEA) of the sandwich beam is performed with the use of the FEM system - ABAQUS. The relationship between the applied load and deflection in three-point bending is considered.

  20. Calculation of dynamic stresses in viscoelastic sandwich beams using oma

    DEFF Research Database (Denmark)

    Pelayo, F.; Aenlle, M. L.; Ismael, G.

    2017-01-01

    The mechanical response of sandwich elements with viscoelastic core is time and temperature dependent. Laminated glass is a sandwich element where the mechanical behavior of the glass layers is usually considered linear-elastic material whereas the core is made of an amorphous thermoplastic which...... data. In simple structures, analytical mode shapes can be used alternatively to the numerical ones. In this paper, the dynamic stresses on the glass layers of a laminated glass beam have estimated using the experimental acceleration responses measured at 7 points of the beam, and the experimental mode...

  1. Study of low-velocity impact response of sandwich panels with shear-thickening gel cores

    Science.gov (United States)

    Wang, Yunpeng; Gong, Xinglong; Xuan, Shouhu

    2018-06-01

    The low-velocity impact response of sandwich panels with shear-thickening gel cores was studied. The impact tests indicated that the sandwich panels with shear-thickening gel cores showed excellent properties of energy dissipation and stress distribution. In comparison to the similar sandwich panels with chloroprene rubber cores and ethylene-propylene-diene monomer cores, the shear-thickening gel cores led to the obviously smaller contact forces and the larger energy absorptions. Numerical modelling with finite element analysis was used to investigate the stress distribution of the sandwich panels with shear-thickening gel cores and the results agreed well with the experimental results. Because of the unique mechanical property of the shear-thickening gel, the concentrated stress on the front facesheets were distributed to larger areas on the back facesheets and the peak stresses were reduced greatly.

  2. Effects of thermal annealing on electrical characteristics of Cd/CdS/n-Si/Au-Sb sandwich structure

    International Nuclear Information System (INIS)

    Saglam, M.; Ates, A.; Guezeldir, B.; Astam, A.; Yildirim, M.A.

    2009-01-01

    In general, at the metal-semiconductor contacts, interfacial layers have been fabricated by different methods such as molecular beam epitaxy, metal organic chemical vapor deposition, sputtering and vacuum evaporation. However, all of these techniques have encountered various difficulties in the deposited films. Instead of these methods, since Successive Ionic Layer Adsorption and Reaction (SILAR) method is simple, fast, sensitive, and less costly to prepare interfacial layer, we have first employed this method in order to prepare Cd/CdS/n-Si/Au-Sb sandwich structure. For this reason, the CdS thin film has been directly formed on n-type Si substrate by means of SILAR method. The Cd/CdS/n-Si/Au-Sb sandwich structure has demonstrated clearly rectifying behaviour by the current-voltage (I-V) curves studied at room temperature. In order to observe the effect of the thermal annealing, this structure has been annealed at temperatures from 50 to 300 deg. C for 3 min in N 2 atmosphere. The characteristic parameters such as barrier height, ideality factor and series resistance of this structure have been calculated from the forward bias I-V characteristics as a function of annealing temperature with different methods. The values of n, Φ b and mean R s of the initial Cd/CdS/n-Si/Au-Sb sandwich structure were found to be 2.31, 0.790 eV and 1.86 kΩ respectively. After annealing at 300 deg. C, these values were changed to 1.89, 0.765 eV and 0.48 kΩ. It has been seen that the barrier height, ideality factor and series resistance have slightly changed with increasing annealing temperature up to 300 deg. C.

  3. Evaluation of commercial ELISA kits for detection of antibodies against bovine atypical pestivirus

    DEFF Research Database (Denmark)

    Larska, Magdalena; Polak, Mirosław P.; Uttenthal, Åse

    A group of emerging bovine pestiviruses becomes a possible threat to Bovine Viral diarrhea virus (BVDV) control and eradication programs in the countries of their origin and in the new continents due to the lack of validated detection methods. The use of ELISA kits may be acheaper, time saving...... and less laborious option allowing screening for antibodies in large populations. Since test specific for emerging and new BVDV strains are still under preparation, the purpose of this work was to evaluate available BVDV antibody ELISA assays for their ability to detect antibodies against Hobi-like viruses....... Analysis of a panel of sera obtained from calves experimentally inoculated with Hobi-like virus (isolated from a calf from Thailand) and BVDV type 1 strain using five different ELISA kits in comparison to neutralization test was performed. The specificity and sensitivity of the tests depended greatly...

  4. PSpice Modeling of a Sandwich Piezoelectric Ceramic Ultrasonic Transducer in Longitudinal Vibration.

    Science.gov (United States)

    Wei, Xiaoyuan; Yang, Yuan; Yao, Wenqing; Zhang, Lei

    2017-09-30

    Sandwiched piezoelectric transducers are widely used, especially in high power applications. For more convenient analysis and design, a PSpice lossy model of sandwiched piezoelectric ultrasonic transducers in longitudinal vibration is proposed by means of the one-dimensional wave and transmission line theories. With the proposed model, the resonance and antiresonance frequencies are obtained, and it is shown that the simulations and measurements have good consistency. For the purpose of further verification the accuracy and application of the PSpice model, a pitch-catch setup and an experimental platform are built. They include two sandwiched piezoelectric ultrasonic transducers and two aluminum cylinders whose lengths are 20 mm and 100 mm respectively. Based on this pitch-catch setup, the impedance and transient analysis are performed. Compared with the measured results, it is shown that the simulated results have good consistency. In addition, the conclusion can be drawn that the optimal excitation frequency for the pitch-catch setup is not necessarily the resonance frequency of ultrasonic transducers, because the resonance frequency is obtained under no load. The proposed PSpice model of the sandwiched piezoelectric transducer is more conveniently applied to combine with other circuits such as driving circuits, filters, amplifiers, and so on.

  5. Viewpoints of working sandwich generation women and occupational therapists on role balance strategies.

    Science.gov (United States)

    Evans, Kiah L; Girdler, Sonya J; Falkmer, Torbjorn; Richmond, Janet E; Wagman, Petra; Millsteed, Jeannine; Falkmer, Marita

    2017-09-01

    Occupational therapists need to be cognizant of evidence-based role balance advice and strategies that women with multigenerational caring responsibilities can implement independently or with minimal assistance, as role balance may not be the primary goal during many encounters with this population. Hence, this study aimed to identify the viewpoints on the most helpful role balance strategies for working sandwich generation women, both from their own perspectives and from the perspective of occupational therapists. This was achieved through a Q methodology study, where 54 statements were based on findings from interviews, sandwich generation literature and occupational therapy literature. In total, 31 working sandwich generation women and 42 occupational therapists completed the Q sort through either online or paper administration. The data were analysed using factor analysis with varimax rotation and were interpreted through collaboration with experts in the field. The findings revealed similarities between working sandwich generation women and occupational therapists, particularly in terms of advocating strategies related to sleep, rest and seeking practical assistance from support networks. Differences were also present, with working sandwich generation women viewpoints tending to emphasize strategies related to coping with a busy lifestyle attending to multiple responsibilities. In contrast, occupational therapy viewpoints prioritized strategies related to the occupational therapy process, such as goal setting, activity focused interventions, monitoring progress and facilitating sustainable outcomes.

  6. Radiant heating tests of several liquid metal heat-pipe sandwich panels

    International Nuclear Information System (INIS)

    Camarda, C.J.; Basiulis, A.

    1983-08-01

    Integral heat pipe sandwich panels, which synergistically combine the thermal efficiency of heat pipes and the structural efficiency of honeycomb sandwich construction, were conceived as a means of alleviating thermal stress problems in the Langley Scramjet Engine. Test panels which utilized two different wickable honeycomb cores, facesheets with screen mesh sintered to the internal surfaces, and a liquid metal working fluid (either sodium or potassium) were tested by radiant heating at various heat load levels. The heat pipe panels reduced maximum temperature differences by 31 percent with sodium working fluid and 45 percent with potassium working fluid. Results indicate that a heat pipe sandwich panel is a potential, simple solution to the engine thermal stress problem. Other interesting applications of the concept include: cold plates for electronic component and circuit card cooling, radiators for large space platforms, low distortion large area structures (e.g., space antennas) and laser mirrors

  7. Face/core interface fracture characterization of mixed mode bending sandwich specimens

    DEFF Research Database (Denmark)

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, L.A.

    2011-01-01

    and PVC H45, H100 and H250 foam core materials were evaluated. A methodology to perform precracking on fracture specimens in order to achieve a sharp and representative crack front is outlined. The mixed mode loading was controlled in the mixed mode bending (MMB) test rig by changing the loading......Debonding of the core from the face sheets is a critical failure mode in sandwich structures. This paper presents an experimental study on face/core debond fracture of foam core sandwich specimens under a wide range of mixed mode loading conditions. Sandwich beams with E‐glass fibre face sheets...... application point (lever arm distance). Finite element analysis was performed to determine the mode‐mixity at the crack tip. The results showed that the face/core interface fracture toughness increased with increased mode II loading. Post failure analysis of the fractured specimens revealed that the crack...

  8. Evaluation of a rabies ELISA as an alternative method to seroneutralisation tests in the context of international trade of domestic carnivores.

    Science.gov (United States)

    Wasniewski, M; Labbe, A; Tribout, L; Rieder, J; Labadie, A; Schereffer, J L; Cliquet, F

    2014-01-01

    For several years, international movements with pets have greatly increased. Most countries have relaxed their quarantine measures and adopted a scheme combining vaccination of pets against rabies followed by a serological test to check the efficacy of vaccination. This new scheme has been strongly supported by the OIE, WHO and the European Commission to facilitate the free movement of people and pets around the world. Currently, only two reference methods are recognised and prescribed (the FAVN test and the RFFIT) to measure rabies antibody levels in serum samples for international trade. They are reliable and valuable methods of assessing the efficacy of rabies vaccination but they are time-consuming and require well-trained people and specialised laboratory facilities. A few years ago, an ELISA (Platelia™ Rabies II kit ad usum Veterinarium) was developed for domestic carnivores and wildlife. To our knowledge, this ELISA is the only one certified and prescribed by the OIE. Following its marketing, one task of the EURL for rabies serology was to evaluate the performance of laboratories using this new kit. The results revealed that 26% of the participants, which were already approved laboratories for rabies serology, failed the inter-laboratory trial. Such unsatisfactory results have never been observed during any of the previous proficiency tests organised annually since 2000 by the EURL for rabies serology using reference methods. More investigations were undertaken through internal and collaborative studies to assess the performance of this newly marketed ELISA kit. The results of the internal study revealed that even with a specificity of 100%, the sensitivity evaluated on 593 samples of domestic carnivores came to 78.2%. An issue regarding the underestimation of serum titres was also revealed during the study. The results of a collaborative study involving 23 international laboratories reinforced the preliminary conclusions regarding lack of sensitivity

  9. Sound insulation of composite cylindrical shells: a comparison between a laminated and a sandwich cylinder

    OpenAIRE

    Yuan, Chongxin; Roozen, Bert; Bergsma, Otto; Beukers, Adriaan

    2012-01-01

    The fuselages of aircraft are modeled as a cylinder in this paper, and the sound insulations of a sandwich cylinder and a laminated cylinder are studied both experimentally and numerically. The cylinders are excited by an acoustic pressure and a mechanical force respectively. Results show that under acoustic excitation, the sandwich cylinder and the laminated one have a similar sound insulation below 3000 Hz, but the sandwich cylinder has a much larger sound insulation at higher frequencies. ...

  10. AN EVALUATION STUDY OF ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA USING RECOMBINANT PROTEIN GRA1 FOR DETECTION OF IGG ANTIBODIES AGAINTS TOXOPLASMA GONDII INFECTIONS

    Directory of Open Access Journals (Sweden)

    Nina Difla Muflikhah

    2017-08-01

    Full Text Available Toxoplasmosis is an infectious disease caused by Toxoplasma gondii, an intracellular protozoan parasite that live inside the cells of the reticulo endothelial and parenchymal cells of human and animals (mammals and birds. Some cases of toxoplasmosis usually have no symptoms, but in any cases caused severe symptoms, such as hydrocephalus, microcephalus, intracranial calcification, retinal damage, brain abscess, mental retardation, lymphadenopathy, and others. Its severe symptoms usually showed a long time after first exposure, except symptoms showed by congenital transmission caused by infected mother. Early diagnosis is important to prevent the illness but methods for toxoplasmosis screening are still too expensive for developing country. Enzyme-linked immunosorbent assay (ELISA allow the testing of a large number samples within short time frame and based on antibody or antigen detection. This study aimed to know the sensitivity and specificity of recombinat protein GRA1 as antigen using ELISA methods. We tested the sensitivity and spesificity of GRA1 protein as antigen in ELISA methods to diagnose toxoplasmosis and compared with ELISA Kit Commercial. Reliable laboratory testing is important to detect Toxoplasma gondii infection, and focused to improving the low cost and easy-to-use diagnostic instrument. Seventy sera collected and tested using both indirect ELISA, commercial ELISA kit and GRA1 protein coated as antigen. Fourty eight and fifty one samples showed positive IgG antibody result of ELISA-GRA1 and ELISA kit. Negative sample tested by ELISA-GRA1 was 22 samples and 19 sample tested by ELISA Kit. The sensitivity and specificity of GRA1-based on ELISA were 100% and 86.36%, positive prediction value (ppv was 94.11%. These data indicate that the recombinant protein GRA1 is a highly immunogenic protein in human toxoplasmosis and become a promising marker for the screening of toxoplasmosis.

  11. Comparative study of the enzyme linked immunosorbent assay (ELISA) and two radioimmunoassays (RIA'S) for in-sulin

    Energy Technology Data Exchange (ETDEWEB)

    Klimes, I; Jurcovicova, J; Palkovic, M [Slovenska Akademia Vied, Bratislava (Czechoslovakia). Ustav Experimentalnej Endokrinologie

    1978-06-30

    The results of the quality control tests for enzyme linked immunosorbent assay (ELISA) were compared with the results of two different radioimmunoassays (RIA'S) for insulin. Using the manufacturer's procedure for the ELISA kit we found that the analytical variables such as assay sensitivity, recovery study and the 50% binding intercept were in good agreement with those obtained with the RIA method.

  12. Comportamento do método quimioluminescente-ELISA em relação a resultados considerados discordantes por meio de três técnicas convencionais para diagnóstico da doença de Chagas Behavior of the chemiluminescent ELISA method in relation to results considered discordant via three conventional techniques for diagnosing Chagas disease

    Directory of Open Access Journals (Sweden)

    Cláudia Regina De Marchi

    2007-02-01

    Full Text Available Quando utilizadas, em conjunto, a hemaglutinação indireta, a imunofluorescência indireta e ELISA para diagnóstico sorológico da doença de Chagas por vezes ocorrem resultados considerados discordantes, por não haver concordância entre o que indicam essas técnicas. A disponibilidade do método quimioluminescente-ELISA permitiu executá-lo com 200 soros que examinados pelos três testes citados que motivaram a obtenção de resultados discordantes. Com o método quimioluminescente-ELISA sucederam 193 negativos e sete positivos. O emprego desse novo procedimento trouxe mais um subsídio para compreensão do assunto, mas avanço mais concreto dependerá de documentação com soros de pessoas infectadas ou não pelo Trypanosoma cruzi conforme comprovação parasitológica.When indirect hemagglutination, indirect immunofluorescence and enzyme-linked immunosorbent assay are used together for serologically diagnosing Chagas disease, results that are considered discordant sometimes occur because there is disagreement between what these tests indicate. The availability of the chemiluminescent ELISA method enabled tests on 200 serum samples that had previously produced discordant results from the three abovementioned methods. CL-ELISA revealed that 193 of these samples were negative and seven were positive. The use of this new procedure provides further support for understanding this subject, but more concrete advances will depend on documentation with blood analyses from people previously demonstrated to be unquestionably infected or uninfected with Trypanosoma cruzi.

  13. Damage Tolerance of Resin Transfer Molded Composite Sandwich Constructions

    National Research Council Canada - National Science Library

    Vaidya, U

    1999-01-01

    .... The sandwich composite concepts considered in this study possessed the feasibility to improve the transverse stiffness, provide enhanced damage resistance/tolerance to impact and functionality...

  14. An ELISA test for the detection of antibodies to Legionella pneumophila.

    OpenAIRE

    Wreghitt, T G; Nagington, J; Gray, J

    1982-01-01

    An enzyme-linked immunosorbent assay (ELISA) test has been developed to detect antibodies to Legionella pneumophila serogroup 1. There is good correlation between indirect fluorescent antibody (IFA) and ELISA titres but ELISA is more sensitive.

  15. AN ELISA ASSAY FOR HEME OXYGENASE (HO-1)

    Science.gov (United States)

    An ELISA assay for heme oxygenase (HO-l ) Abstract A double antibody capture ELISA for the HO-l protein has been developed to separately quantitate HO-I protein. The use of 2.5% NP40 detergent greatly assists in freeing HO-l protein from membranes and/or other cel...

  16. Validation and implementation of sandwich structure bottom plate to rib weld joint in the base section of ITER Cryostat

    Energy Technology Data Exchange (ETDEWEB)

    Prajapati, Rajnikant, E-mail: rajnikant@iter-india.org [ITER-India, Institute For Plasma Research, A-29, GIDC Electronics Estate, Sector-25, Gandhinagar 382016 (India); Bhardwaj, Anil K.; Gupta, Girish; Joshi, Vaibhav; Patel, Mitul; Bhavsar, Jagrut; More, Vipul; Jindal, Mukesh; Bhattacharya, Avik; Jogi, Gaurav; Palaliya, Amit; Jha, Saroj; Pandey, Manish [ITER-India, Institute For Plasma Research, A-29, GIDC Electronics Estate, Sector-25, Gandhinagar 382016 (India); Jadhav, Pandurang; Desai, Hemal [Larsen & Toubro Limited, Heavy Engineering, Hazira Manufacturing Complex, Gujarat (India)

    2016-11-01

    Highlights: • ITER Cryostat base section sandwich structure bottom plate to rib weld joint is qualified through mock-up. • Established welding sequence was successfully implemented on all six sectors of cryostat base section. • Each layer liquid penetrant examination has been carried out for these weld joints and found satisfactory. - Abstract: Cryostat is a large stainless steel vacuum vessel providing vacuum environment to ITER machine components. The cryostat is ∼30 m in diameter and ∼30 m in height having variable thickness from 25 mm to 180 mm. Sandwich structure of cryostat base section withstands vacuum loading and limits the deformation under service conditions. Sandwich structure consists of top and bottom plates internally strengthened with radial and circular ribs. In current work, sandwich structure bottom plate to rib weld joint has been designed with full penetration joint as per ITER Vacuum Handbook requirement considering nondestructive examinations and welding feasibility. Since this joint was outside the scope of ASME Section VIII Div. 2, it was decided to validate through mock-up of bottom plate to rib joint. Welding sequence was established to control the distortion. Tensile test, macro-structural examination and layer by layer LPE were carried out for validation of this weld joint. However possibility of ultrasonic examination method was also investigated. The test results from the welded joint mock-up were found to confirm all code and specification requirements. The same was implemented in first sector (0–60°) of base section sandwich structure.

  17. Dynamic Failure of Composite and Sandwich Structures

    CERN Document Server

    Abrate, Serge; Rajapakse, Yapa D S

    2013-01-01

    This book presents a broad view of the current state of the art regarding the dynamic response of composite and sandwich structures subjected to impacts and explosions. Each chapter combines a thorough assessment of the literature with original contributions made by the authors.  The first section deals with fluid-structure interactions in marine structures.  The first chapter focuses on hull slamming and particularly cases in which the deformation of the structure affects the motion of the fluid during the water entry of flexible hulls. Chapter 2 presents an extensive series of tests underwater and in the air to determine the effects of explosions on composite and sandwich structures.  Full-scale structures were subjected to significant explosive charges, and such results are extremely rare in the open literature.  Chapter 3 describes a simple geometrical theory of diffraction for describing the interaction of an underwater blast wave with submerged structures. The second section addresses the problem of...

  18. Experimental and Theoretical Deflections of Hybrid Composite Sandwich Panel under Four-point Bending Load

    Directory of Open Access Journals (Sweden)

    Jauhar Fajrin

    2017-03-01

    Full Text Available This paper presents a comparison of theoretical and experimental deflection of a hybrid sandwich panel under four-point bending load. The paper initially presents few basic equations developed under three-point load, followed by development of model under four-point bending load and a comparative analysis between theoretical and experimental results. It was found that the proposed model for predicting the deflection of hybrid sandwich panels provided fair agreement with the experimental values. Most of the sandwich panels showed theoretical deflection values higher than the experimental values, which is desirable in the design. It was also noticed that the introduction of intermediate layer does not contribute much to reduce the deflection of sandwich panel as the main contributor for the total deflection was the shear deformation of the core that mostly determined by the geometric of the samples and the thickness of the core.

  19. Using a silver-enhanced microarray sandwich structure to improve SERS sensitivity for protein detection.

    Science.gov (United States)

    Gu, Xuefang; Yan, Yuerong; Jiang, Guoqing; Adkins, Jason; Shi, Jian; Jiang, Guomin; Tian, Shu

    2014-03-01

    A simple and sensitive method, based on surface-enhanced Raman scattering (SERS), for immunoassay and label-free protein detection is reported. A series of bowl-shaped silver cavity arrays were fabricated by electrodeposition using a self-assembled polystyrene spheres template. The reflection spectra of these cavity arrays were recorded as a function of film thickness, and then correlated with SERS enhancement using sodium thiophenolate as the probe molecule. The results reveal that SERS enhancement can be maximized when the frequency of both the incident laser and the Raman scattering approach the frequency of the localized surface plasmon resonance. The optimized array was then used as the bottom layer of a silver nanoparticle-protein-bowl-shaped silver cavity array sandwich. The second layer of silver was introduced by the interactions between the proteins in the middle layer of the sandwich architecture and silver nanoparticles. Human IgG bound to the surface of this microcavity array can retain its recognition function. With the Raman reporter molecules labeled on the antibody, a detection limit down to 0.1 ng mL(-1) for human IgG is easily achieved. Furthermore, the SERS spectra of label-free proteins (catalase, cytochrome C, avidin and lysozyme) from the assembled sandwich have excellent reproducibility and high quality. The results reveal that the proposed approach has potential for use in qualitative and quantitative detection of biomolecules.

  20. A novel Python program for implementation of quality control in the ELISA.

    Science.gov (United States)

    Wetzel, Hanna N; Cohen, Cinder; Norman, Andrew B; Webster, Rose P

    2017-09-01

    The use of semi-quantitative assays such as the enzyme-linked immunosorbent assay (ELISA) requires stringent quality control of the data. However, such quality control is often lacking in academic settings due to unavailability of software and knowledge. Therefore, our aim was to develop methods to easily implement Levey-Jennings quality control methods. For this purpose, we created a program written in Python (a programming language with an open-source license) and tested it using a training set of ELISA standard curves quantifying the Fab fragment of an anti-cocaine monoclonal antibody in mouse blood. A colorimetric ELISA was developed using a goat anti-human anti-Fab capture method. Mouse blood samples spiked with the Fab fragment were tested against a standard curve of known concentrations of Fab fragment in buffer over a period of 133days stored at 4°C to assess stability of the Fab fragment and to generate a test dataset to assess the program. All standard curves were analyzed using our program to batch process the data and to generate Levey-Jennings control charts and statistics regarding the datasets. The program was able to identify values outside of two standard deviations, and this identification of outliers was consistent with the results of a two-way ANOVA. This program is freely available, which will help laboratories implement quality control methods, thus improving reproducibility within and between labs. We report here successful testing of the program with our training set and development of a method for quantification of the Fab fragment in mouse blood. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Therapeutic Results of Radiotherapy in Rectal Carcinoma -Comparison of Sandwich Technique Radiotherapy with Postoperative Radiotherapy

    International Nuclear Information System (INIS)

    Huh, Gil Cha; Suh, Hyun Suk; Lee, Hyuk Sang; Kim, Re Hwe; Kim, Chul Soo; Kim, Hong Yong; Kim, Sung Rok

    1996-01-01

    Purpose : To evaluate the potential advantage for 'sandwich' technique radiotherapy compared to postoperative radiotherapy in respectable rectal cancer. Between January 1989 and May 1994, 60 patients with respectable rectal cancer were treated at Inje University Seoul and Sanggye Paik Hospital.Fifty one patients were available for analysis : 20 patients were treated with sandwich technique radiotherapy and 31 patients were treated with postoperative radiotherapy. In sandwich technique radiotherapy(RT), patients were treated with preoperative RT 1500 cGy/5fx followed by immediate curative resection. Patients staged as Astler-Coller B2, C were considered for postoperative RT with 2500-4500 cGy. In postoperative RT, total radiation dose of 4500-6120 cGy, 180 cGy daily at 4-6 weeks was delivered. Patients were followed for median period of 25 months. Results : The overall 5-year survival rates for sandwich technique RT group and postoperative RT group were 60% and 71%, respectively(p>0.05). The 5-year disease free survival rates for each group were 63%. There was no difference in local failure rate between two groups(11% versus 7%). Incidence of distant metastasis was 11%(2/20) in the sandwich technique RT group and 20%(6/31) in the postoperative RT group(p>0.05). The frequencies of acute and chronic complications were comparable in both groups. Conclusion : The sandwich technique radiotherapy group shows local recurrence and survival similar to those of postoperative RT alone group but reduced distant metastasis compared to postoperative RT group. But long term follow-up and large number of patients is needed to make an any firm conclusion regarding the value of this sandwich technique RT

  2. The Fluid-Solid Interaction Dynamics between Underwater Explosion Bubble and Corrugated Sandwich Plate

    Directory of Open Access Journals (Sweden)

    Hao Wang

    2016-01-01

    Full Text Available Lightweight sandwich structures with highly porous 2D cores or 3D (three-dimensional periodic cores can effectively withstand underwater explosion load. In most of the previous studies of sandwich structure antiblast dynamics, the underwater explosion (UNDEX bubble phase was neglected. As the UNDEX bubble load is one of the severest damage sources that may lead to structure large plastic deformation and crevasses failure, the failure mechanisms of sandwich structures might not be accurate if only shock wave is considered. In this paper, detailed 3D finite element (FE numerical models of UNDEX bubble-LCSP (lightweight corrugated sandwich plates interaction are developed by using MSC.Dytran. Upon the validated FE model, the bubble shape, impact pressure, and fluid field velocities for different stand-off distances are studied. Based on numerical results, the failure modes of LCSP and the whole damage process are obtained. It is demonstrated that the UNDEX bubble collapse jet local load plays a more significant role than the UNDEX shock wave load especially in near-field underwater explosion.

  3. Sandwich panels with high performance concrete thin plates at elevated temperatures

    DEFF Research Database (Denmark)

    Hulin, Thomas; Hodicky, Kamil; Schmidt, Jacob Wittrup

    2015-01-01

    concerned HMT modelling and elastic stress analysis with nonlinear temperature effects of a full size loaded sandwich wall, qualitatively assessing the location of critically stressed zones. Modelling output was compared to published experimental results. The model reproduced experimental temperature...... recordings satisfactorily, except phase changes of water at low heating rates. It was suggested that the function governing moisture evolution with temperature and pressure should be updated for HPC. Pore pressure was found critical for sandwich structures due their higher temperatures. Adding polypropylene...

  4. Veterans' informal caregivers in the "sandwich generation": a systematic review toward a resilience model.

    Science.gov (United States)

    Smith-Osborne, Alexa; Felderhoff, Brandi

    2014-01-01

    Social work theory advanced the formulation of the construct of the sandwich generation to apply to the emerging generational cohort of caregivers, most often middle-aged women, who were caring for maturing children and aging parents simultaneously. This systematic review extends that focus by synthesizing the literature on sandwich generation caregivers for the general aging population with dementia and for veterans with dementia and polytrauma. It develops potential protective mechanisms based on empirical literature to support an intervention resilience model for social work practitioners. This theoretical model addresses adaptive coping of sandwich- generation families facing ongoing challenges related to caregiving demands.

  5. Failure analysis of bolted joints in foam-core sandwich composites

    DEFF Research Database (Denmark)

    Zabihpoor, M.; Moslemian, Ramin; Afshin, M.

    2008-01-01

    This study represents an effort to predict the bearing strength, failure modes, and failure load of bolted joints in foam-core sandwich composites. The studied joints have been used in a light full composite airplane. By using solid laminates, a new design for the joint zone is developed. These s......This study represents an effort to predict the bearing strength, failure modes, and failure load of bolted joints in foam-core sandwich composites. The studied joints have been used in a light full composite airplane. By using solid laminates, a new design for the joint zone is developed...

  6. Sensitive radioimmunosorbent assay for the detection of plant viruses. [Cauliflower mosaic virus, lettuce mosaic virus

    Energy Technology Data Exchange (ETDEWEB)

    Ghabrial, S A; Shepherd, R J [Kentucky Univ., Lexington (USA); California Univ., Davis (USA))

    1980-06-01

    A simple and highly sensitive radioimmunosorbent assay (RISA) for the detection of plant viruses is described. The RISA procedure is a microplate method based on the principle of 'double-antibody sandwich' and follows essentially the protocol of the enzyme-linked immunosorbent assay (ELISA) (Clark and Adams, 1977), with the exception that /sup 125/I-labelled ..gamma..-globulin is substituted for the ..gamma..-globulin enzyme conjugate; the bound /sup 125/I-..gamma..-globulin is dissociated by acidification from the double-antibody sandwich. The radioactivity is proportional to virus concentration, and cauliflower mosaic virus (CaMV) and lettuce mosaic virus (LMV) could be detected at concentrations as low as 5 and 2 ng/ml, respectively. Direct evidence of the adverse effects of conjugation with enzyme on the binding abilities of antibodies is presented. The RISA procedure should prove valuable with viruses for which the ELISA values are too low to be dependable.

  7. A sensitive radioimmunosorbent assay for the detection of plant viruses

    International Nuclear Information System (INIS)

    Ghabrial, S.A.; Shepherd, R.J.

    1980-01-01

    A simple and highly sensitive radioimmunosorbent assay (RISA) for the detection of plant viruses is described. The RISA procedure is a microplate method based on the principle of 'double-antibody sandwich' and follows essentially the protocol of the enzyme-linked immunosorbent assay (ELISA) (Clark and Adams, 1977), with the exception that 125 I-labelled γ-globulin is substituted for the γ-globulin enzyme conjugate; the bound 125 I-γ-globulin is dissociated by acidification from the double-antibody sandwich. The radioactivity is proportional to virus concentration, and cauliflower mosaic virus (CaMV) and lettuce mosaic virus (LMV) could be detected at concentrations as low as 5 and 2 ng/ml, respectively. Direct evidence of the adverse effects of conjugation with enzyme on the binding abilities of antibodies is presented. The RISA procedure should prove valuable with viruses for which the ELISA values are too low to be dependable. (author)

  8. Electrical switching and memory phenomena observed in redox-gradient dendrimer sandwich devices

    OpenAIRE

    Li, JianChang; Blackstock, Silas C.; Szulczewski, Greg J.

    2005-01-01

    We report on the fabrication of dendrimer sandwich devices with electrical switching and memory properties. The storage media is consisted of a redox-gradient dendrimer layer sandwiched in organic barrier thin films. The dendrimer layer acts as potential well where redox-state changes and consequent electrical transitions of the embedded dendrimer molecules are expected to be effectively triggered and retained, respectively. Experimental results indicated that electrical switching could be re...

  9. Comparison of DOT-ELISA and Standard-ELISA for Detection of the Vibrio cholerae Toxin in Culture Supernatants of Bacteria Isolated from Human and Environmental Samples.

    Science.gov (United States)

    Meza-Lucas, Antonio; Pérez-Villagómez, María-Fernanda; Martínez-López, José-Patricio; García-Rodea, Ricardo; Martínez-Castelán, María-Guadalupe; Escobar-Gutiérrez, Alejandro; de-la-Rosa-Arana, Jorge-Luis; Villanueva-Zamudio, Altagracia

    2016-09-01

    A comparison of DOT-ELISA and Standard-ELISA was made for detection of Vibrio cholerae toxin in culture supernatants of bacteria isolated from human and environmental samples. A total of 293 supernatants were tested in a double blind assay. A correlation of 100 % was obtained between both techniques. The cholera toxin was found in 20 Inaba and 3 Ogawa strains. Positive samples were from seafood (17 samples), potable water (1 sample) and sewage (5 samples). The DOT-ELISA was useful as the standard-ELISA to confirm the presence of cholera toxin in the environmental samples.

  10. FINITE ELEMENT MODELING OF THIN CIRCULAR SANDWICH PLATES DEFLECTION

    Directory of Open Access Journals (Sweden)

    K. S. Kurachka

    2014-01-01

    Full Text Available A mathematical model of a thin circular sandwich plate being under the vertical load is proposed. The model employs the finite element method and takes advantage of an axisymmetric finite element that leads to the small dimension of the resulting stiffness matrix and sufficient accuracy for practical calculations. The analytical expressions for computing local stiffness matrices are found, which can significantly speed up the process of forming the global stiffness matrix and increase the accuracy of calculations. A software is under development and verification. The discrepancy between the results of the mathematical model and those of analytical formulas for homogeneous thin circularsandwich plates does not exceed 7%.

  11. Testing of the scintillation sandwich prototype

    International Nuclear Information System (INIS)

    Vashkevich, V.

    1995-06-01

    The 3 m 2 prototype of the surface detector using optical fiber readout was completely prepared for testing measurements in February 1995 at Fermilab. Two 25 mm thick, 3 m 2 acrylic scintillation plates (1.2 x 2.5 m 2 ) are used for light collection in the upper (above the 25 mm steel plate) and lower (below the steel) counters of the sandwich. The light is collected with the help of 1 mm diameter wavelength shifter fiber loops 3 m long inserted in the grooves on the top surface of the scintillator, 3 fibers per groove. We used Kurary Y11, 200 ppm of shifter dye, and double clad fibers. 1.5 m of clear fibers spliced to each end of the shifter fiber transport the light to the phototube. Spacing between the grooves is 5 cm. The counter's edges were painted with BICRON (BC620) white reflective paint. The scintillation plates were wrapped with Dupont Tyvek. The glued bundle of fibers is connected to an EMI-9902KB 38 mm phototube through the simple light mixer bar. Used PM has a ''green extended'' rubidium bialkali photocathode. The report contains information on the testing of the scintillation sandwich

  12. Cornelius Elisa Bertus Bremekamp

    NARCIS (Netherlands)

    Lanjouw, J.

    1969-01-01

    Cornelis Elisa Bertus Bremekamp was born at Dordrecht on February 7th 1888. He is therefore now just past eighty, and he has been a member of the Koninklijke Nederlandse Botanische Vereniging for sixty years. He studied at the Utrecht State University and, like many of his contemporaries, was

  13. The Effect of Face Sheet Wrinkle Defects on the Strength of FRP Sandwich Structures

    DEFF Research Database (Denmark)

    Hayman, Brian; Berggreen, Christian; Pettersson, Robert

    2007-01-01

    . In the studies reported here, the influence of wrinkle defects on the in-plane compressive strength of quasi-isotropic carbon fiber reinforced plastic (CFRP) laminates used in PVC foam-cored sandwich panels has been investigated by three approaches: testing of sandwich beam specimens in four-point bending...

  14. Changing Welfare States and the “Sandwich Generation” : Increasing Burden for the Next Generation?

    Directory of Open Access Journals (Sweden)

    Harald Künemund

    2006-12-01

    Full Text Available The burden placed on individuals aged 40 to 59 – especially on women – by competing demands from work and both older and younger family members is often addressed using the metaphor of the „sandwich gen-eration“. Based on a systematization of the definitions used in the litera-ture, empirical evidence on the frequency of such generational constella-tions and on their impact on the well-being of sandwiched adults will be presented. Analysing the second wave of the German Aging Survey shows that being sandwiched – defined as a generational constellation – is very common, but simultaneous care activities for both older and younger family members are rare, especially in combination with labour force participation, and that life satisfaction is not systematically related to being sandwiched. Implications for further research and future devel-opments will be discussed, especially with respect to changes in family structure (e.g. the beanpole family and changes in the amount of welfare state spending for the aged.

  15. A novel sandwich Fe-Mn damping alloy with ferrite shell prepared by vacuum annealing

    Science.gov (United States)

    Qian, Bingnan; Peng, Huabei; Wen, Yuhua

    2018-04-01

    To improve the corrosion resistance of high strength Fe-Mn damping alloys, we fabricated a novel sandwich Fe-17.5Mn damping alloy with Mn-depleted ferrite shell by vacuum annealing at 1100 °C. The formation behavior of the ferrite shell obeys the parabolic law for the vacuum annealed Fe-17.5Mn alloy at 1100 °C. The sandwich Fe-17.5Mn alloy with ferrite shell exhibits not only better corrosion resistance but also higher damping capacity than the conventional annealed Fe-17.5Mn alloy under argon atmosphere. The existence of only ferrite shell on the surface accounts for the better corrosion in the sandwich Fe-17.5Mn alloy. The better damping capacity in the sandwich Fe-17.5Mn alloy is owed to more stacking faults inside both ɛ martensite and γ austenite induced by the stress from ferrite shell. Vacuum annealing is a new way to improve the corrosion resistance and damping capacity of Fe-Mn damping alloys.

  16. Laser cutting sandwich structure glass-silicon-glass wafer with laser induced thermal-crack propagation

    Science.gov (United States)

    Cai, Yecheng; Wang, Maolu; Zhang, Hongzhi; Yang, Lijun; Fu, Xihong; Wang, Yang

    2017-08-01

    Silicon-glass devices are widely used in IC industry, MEMS and solar energy system because of their reliability and simplicity of the manufacturing process. With the trend toward the wafer level chip scale package (WLCSP) technology, the suitable dicing method of silicon-glass bonded structure wafer has become necessary. In this paper, a combined experimental and computational approach is undertaken to investigate the feasibility of cutting the sandwich structure glass-silicon-glass (SGS) wafer with laser induced thermal-crack propagation (LITP) method. A 1064 nm semiconductor laser cutting system with double laser beams which could simultaneously irradiate on the top and bottom of the sandwich structure wafer has been designed. A mathematical model for describing the physical process of the interaction between laser and SGS wafer, which consists of two surface heating sources and two volumetric heating sources, has been established. The temperature stress distribution are simulated by using finite element method (FEM) analysis software ABAQUS. The crack propagation process is analyzed by using the J-integral method. In the FEM model, a stationary planar crack is embedded in the wafer and the J-integral values around the crack front edge are determined using the FEM. A verification experiment under typical parameters is conducted and the crack propagation profile on the fracture surface is examined by the optical microscope and explained from the stress distribution and J-integral value.

  17. Compressive properties of sandwiches with functionally graded

    Indian Academy of Sciences (India)

    The compressive behaviour of a new class of sandwich composite made up of jute fiber reinforced epoxy skins and piece-wise linear fly ash reinforced functionally graded (FG) rubber core is investigated in flat-wise mode. FG samples are prepared using conventional casting technique. Presence of gradation is quantified ...

  18. Detection of carcinoembryonic antigen using functional magnetic and fluorescent nanoparticles in magnetic separators

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, H. Y., E-mail: annetsai@csmu.edu.tw [Chung Shan Medical University, Department of Applied Chemistry (China); Chang, C. Y.; Li, Y. C.; Chu, W. C.; Viswanathan, K.; Bor Fuh, C., E-mail: cbfuh@ncnu.edu.tw [National Chi Nan University, Department of Applied Chemistry (China)

    2011-06-15

    We combined a sandwich immunoassay, anti-CEA/CEA/anti-CEA, with functional magnetic ({approx}80 nm) and fluorescent ({approx}180 nm) nanoparticles in magnetic separators to demonstrate a detection method for carcinoembryonic antigen (CEA). Determination of CEA in serum can be used in clinical diagnosis and monitoring of tumor-related diseases. The CEA concentrations in samples were deduced and determined based on the reference plot using the measured fluorescent intensity of sandwich nanoparticles from the sample. The linear range of CEA detection was from 18 ng/mL to 1.8 pg/mL. The detection limit of CEA was 1.8 pg/mL. In comparison with most other detection methods, this method had advantages of lower detection limit and wider linear range. The recovery was higher than 94%. The CEA concentrations of two serum samples were determined to be 9.0 and 55 ng/mL, which differed by 6.7% (9.6 ng/mL) and 9.1% (50 ng/mL) from the measurements of enzyme-linked immunosorbent assay (ELISA), respectively. The analysis time can be reduced to one third of ELISA. This method has good potential for other biomarker detections and biochemical applications.

  19. PSpice Modeling of a Sandwich Piezoelectric Ceramic Ultrasonic Transducer in Longitudinal Vibration

    Directory of Open Access Journals (Sweden)

    Xiaoyuan Wei

    2017-09-01

    Full Text Available Sandwiched piezoelectric transducers are widely used, especially in high power applications. For more convenient analysis and design, a PSpice lossy model of sandwiched piezoelectric ultrasonic transducers in longitudinal vibration is proposed by means of the one-dimensional wave and transmission line theories. With the proposed model, the resonance and antiresonance frequencies are obtained, and it is shown that the simulations and measurements have good consistency. For the purpose of further verification the accuracy and application of the PSpice model, a pitch-catch setup and an experimental platform are built. They include two sandwiched piezoelectric ultrasonic transducers and two aluminum cylinders whose lengths are 20 mm and 100 mm respectively. Based on this pitch-catch setup, the impedance and transient analysis are performed. Compared with the measured results, it is shown that the simulated results have good consistency. In addition, the conclusion can be drawn that the optimal excitation frequency for the pitch-catch setup is not necessarily the resonance frequency of ultrasonic transducers, because the resonance frequency is obtained under no load. The proposed PSpice model of the sandwiched piezoelectric transducer is more conveniently applied to combine with other circuits such as driving circuits, filters, amplifiers, and so on.

  20. Cystatin capture elisa immunodiagnosis of human fasciolosis at Chupaca-Junin Province

    International Nuclear Information System (INIS)

    Cornejo, W.; Alva, P.; Sevilla, C.; Huiza, A.; Universidad Nacional Mayor de San Marcos, Lima

    2003-01-01

    To determine the prevalence of human fasciolosis in an endemic area by means of an Enzyme-Linked Immunosorbent Assay (ELISA) using cystatin as a capture agent for the detection of specific antibodies to fasciola hepatica cysteine proteinases. An ELISA plate was sensitized with cystatin, incubated with excretory-secretory products of adult flukes, and followed by standard ELISA procedures. Clinical applicability of the cystatin capture ELISA for the immunodiagnosis of fasciolosis was tested with 200 serum samples of children and adults from an endemic area in Chupaca province, Junin department. Serum samples from the endemic area tested by cystatin capture ELISA showed 27/200 (13,5%) of positive cases. Fasciolosis remains a major health problem at Chupaca province, Junin department

  1. Experimental study of the mechanical behaviour of pin reinforced foam core sandwich materials under shear load

    International Nuclear Information System (INIS)

    Dimassi, M A; Brauner, C; Herrmann, A S

    2016-01-01

    Sandwich structures with a lightweight closed cell hard foam core have the potential to be used in primary structures of commercial aircrafts. Compared to honeycomb core sandwich, the closed cell foam core sandwich overcomes the issue of moisture take up and makes the manufacturing of low priced and highly integrated structures possible. However, lightweight foam core sandwich materials are prone to failure by localised external loads like low velocity impacts. Invisible cracks could grow in the foam core and threaten the integrity of the structure. In order to enhance the out-of-plane properties of foam core sandwich structures and to improve the damage tolerance (DT) dry fibre bundles are inserted in the foam core. The pins are infused with resin and co-cured with the dry fabric face sheets in an out-of-autoclave process. This study presents the results obtained from shear tests following DIN 53294-standard, on flat sandwich panels. All panels were manufactured with pin-reinforcement manufactured with the Tied Foam Core Technology (TFC) developed by Airbus. The effects of pin material (CFRP and GFRP) and pin volume fraction on the shear properties of the sandwich structure and the crack propagation were investigated and compared to a not pinned reference. It has been concluded that the pin volume fraction has a remarkable effect on the shear properties and damage tolerance of the observed structure. Increasing the pin volume fraction makes the effect of crack redirection more obvious and conserves the integrity of the structure after crack occurrence. (paper)

  2. Comparison of RT-PCR-Dot blot hybridization based on radioisotope 32P with conventional RT-PCR and commercial ELISA Assays for blood screening of HIV-1

    International Nuclear Information System (INIS)

    Maria Lina R; Andi Yasmon

    2011-01-01

    There are many commercial ELISA and rapid test kits that have been used for blood screening; however, the kits can give false positive and negative results. Therefore, RT-PCR (Reverse Transcription Polymerase Chain Reaction) - Dot Blot Hybridization based on radioisotope 32 P (RDBR) method was developed in this research, to compare the method with the conventional RT-PCR and commercial ELISA Enzyme-Linked lmmunosorbent Assay) kit. This method is efficient for screening of large blood specimens and surveillance study. Eighty seven samples were used and serum of the samples were tested by ELISA to detect HIV-1. The HIV-l RNA genome was extracted from plasma samples and tested using the RT-PCR and RDBR methods. Of 87 samples that were tested, the rates of positive testing of the RT-PCR, the RDBR, and the ELISA were 71.26%, 74.71%, and 80.46%, respectively. The RDBR (a combination of RTPCR and dot blot hybridization) was more sensitive than conventional RT-PCR by showing 3.45% in increase number of positive specimens. The results showed that of 9 samples (10.34%) were negative RDBR and positive ELISA, while 4 samples (4.60%) were negative ELISA and positive RDBR. The two methods showed slightly difference in the results but further validation is still needed. However, RDBR has high potential as an alternative method for screening of blood in large quantities when compared to method of conventional RT-PCR and ELISA. (author)

  3. Detection of alpha-fetoprotein in magnetic immunoassay of thin channels using biofunctional nanoparticles

    Science.gov (United States)

    Tsai, H. Y.; Gao, B. Z.; Yang, S. F.; Li, C. S.; Fuh, C. Bor

    2014-01-01

    This paper presents the use of fluorescent biofunctional nanoparticles (10-30 nm) to detect alpha-fetoprotein (AFP) in a thin-channel magnetic immunoassay. We used an AFP model biomarker and s-shaped deposition zones to test the proposed detection method. The results show that the detection using fluorescent biofunctional nanoparticle has a higher throughput than that of functional microparticle used in previous experiments on affinity reactions. The proposed method takes about 3 min (versus 150 min of previous method) to detect 100 samples. The proposed method is useful for screening biomarkers in clinical applications, and can reduce the run time for sandwich immunoassays to less than 20 min. The detection limits (0.06 pg/ml) and linear ranges (0.068 pg/ml-0.68 ng/ml) of AFP using fluorescent biofunctional nanoparticles are the same as those of using functional microparticles within experimental errors. This detection limit is substantially lower and the linear range is considerably wider than those of enzyme-linked immunosorbent assay (ELISA) and other methods in sandwich immunoassay methods. The differences between this method and an ELISA in AFP measurements of serum samples were less than 12 %. The proposed method provides simple, fast, and sensitive detection with a high throughput for biomarkers.

  4. Evaluation of the Impact Resistance of Various Composite Sandwich Beams by Vibration Tests

    Directory of Open Access Journals (Sweden)

    Amir Shahdin

    2011-01-01

    Full Text Available Impact resistance of different types of composite sandwich beams is evaluated by studying vibration response changes (natural frequency and damping ratio. This experimental works will help aerospace structural engineer in assess structural integrity using classification of impact resistance of various composite sandwich beams (entangled carbon and glass fibers, honeycomb and foam cores. Low velocity impacts are done below the barely visible impact damage (BVID limit in order to detect damage by vibration testing that is hardly visible on the surface. Experimental tests are done using both burst random and sine dwell testing in order to have a better confidence level on the extracted modal parameters. Results show that the entangled sandwich beams have a better resistance against impact as compared to classical core materials.

  5. Effect of Reinforced Hybrid Palm Shells on Mechanical Properties of Polyurethane-Jute Woven/ Vinyl Ester Sandwich Board

    International Nuclear Information System (INIS)

    Cheng, T.S.; Nurul Ain Nanyan; Lan, D.N.U.; Leng, T.P.

    2014-01-01

    A natural fiber sandwich was constructed from palm shells/polyurethane core and jute woven/vinyl ester face sheets by the in-situ sandwich process (core and panel prepared simultaneously). The polyurethane sandwich core was reinforced by hybrid shell systems of dried palm shell (DPS) and palm kernel shell (PKS) (50P-50D, 25P-75D), and single shell system of PKS (100P) as well as 20 phr empty fruit bunch (EFB) based on hundred part of polyurethane. The sandwich face sheets are prepared by using two jute woven layers and impregnated by vinyl ester. Interlocking between DPS and polyurethane matrix was formed, which hence enhanced the mechanical properties. The interfacial adhesion between DPS, PKS, and EFB with the polyurethane binder played the important role to achieve high mechanical properties. It was found that hybrid shells exhibited high reinforcement for sandwich's performance resulting better compression (50P-50D) and flexural (25P-75D) properties. The single shell 100P showed only improvement on flexural modulus.The fracture surface morphology of sandwich under mechanical test was performed by using optical microscopy. (author)

  6. ELISA validation and determination of cut-off level for chloramphenicol residues in honey

    Directory of Open Access Journals (Sweden)

    Biernacki Bogumił

    2015-09-01

    Full Text Available An analytical validation of a screening ELISA for detection of chloramphenicol (CAP in honey was conducted according to the Commission Decision 2002/657/EC and Guidelines for the Validation of Screening Methods for Residues of Veterinary Medicines. The analyte was extracted from honey with a water and ethyl acetate mixture, and CAP concentrations were measured photometrically at 450 nm. The recovery rate of the analyte from spiked samples was 79%. The cut-off level of CAP in honey as the minimum recovery (0.17 units was established. Detection capability (CCβ was fixed at 0.25 μg kg−1. No relevant interferences between matrix effects and structurally related substances including florfenicol and thiamphenicol were observed. The ELISA method should be useful for determination of CAP residues in honey monitoring.

  7. Anti-signal recognition particle autoantibody ELISA validation and clinical associations.

    Science.gov (United States)

    Aggarwal, Rohit; Oddis, Chester V; Goudeau, Danielle; Fertig, Noreen; Metes, Ilinca; Stephens, Chad; Qi, Zengbiao; Koontz, Diane; Levesque, Marc C

    2015-07-01

    The aim of this study was to develop and validate a quantitative anti-signal recognition particle (SRP) autoantibody serum ELISA in patients with myositis and longitudinal association with myositis disease activity. We developed a serum ELISA using recombinant purified full-length human SRP coated on ELISA plates and a secondary antibody that bound human IgG to detect anti-SRP binding. Protein immunoprecipitation was used as the gold standard for the presence of anti-SRP. Serum samples from three groups were analysed: SRP(+) myositis subjects by immunoprecipitation, SRP(-) myositis subjects by immunoprecipitation and non-myositis controls. The ELISA's sensitivity, specificity, positive predictive value and negative predictive value were evaluated. Percentage agreement and test-retest reliability were assessed. Serial samples from seven SRP immunoprecipitation-positive subjects were also tested, along with serum muscle enzymes and manual muscle testing. Using immunoprecipitation, we identified 26 SRP(+) myositis patients and 77 SRP(-) controls (including 38 patients with necrotizing myopathy). Non-myositis control patients included SLE (n = 4) and SSc (n = 7) patients. Anti-SRP positivity by ELISA showed strong agreement (97.1%) with immunoprecipitation (κ = 0.94). The sensitivity, specificity, positive predictive value, and negative predictive value of the anti-SRP ELISA were 88, 100, 100 and 96, respectively. The area under the curve was 0.94, and test-retest reliability was strong (r = 0.91, P < 0.001). Serial samples showed that anti-SRP levels paralleled changes in muscle enzymes and manual muscle testing. We developed a quantitative ELISA for detecting serum anti-SRP autoantibodies and validated the assay in myositis. Longitudinal assessment of SRP levels by ELISA may be a useful biomarker for disease activity. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions

  8. Analysis of a ceramic filled bio-plastic composite sandwich structure

    International Nuclear Information System (INIS)

    Habib Ullah, M.; Islam, M. T.

    2013-01-01

    Design and analysis of a ceramic-filled bio-plastic composite sandwich structure is presented. This proposed high-dielectric structure is used as a substrate for patch antennas. A meandered-strip line-fed fractal-shape patch antenna is designed and fabricated on a copper-laminated sandwich-structured substrate. Measurement results of this antenna show 44% and 20% of bandwidths with maximum gains of 3.45 dBi and 5.87 dBi for the lower and upper bands, respectively. The half-power beam widths of 104° and 78° have been observed from the measured radiation pattern at the two resonance frequencies 0.9 GHz and 2.5 GHz

  9. Analysis of a ceramic filled bio-plastic composite sandwich structure

    Energy Technology Data Exchange (ETDEWEB)

    Habib Ullah, M. [Institute of Space Science (ANGKASA), Universiti Kebangsaan Malaysia, Bangi Selangor 43600 (Malaysia); Department of Electrical, Electronic and System Engineering, Universiti Kebangsaan Malaysia, Bangi 43600 (Malaysia); Islam, M. T. [Institute of Space Science (ANGKASA), Universiti Kebangsaan Malaysia, Bangi Selangor 43600 (Malaysia)

    2013-11-25

    Design and analysis of a ceramic-filled bio-plastic composite sandwich structure is presented. This proposed high-dielectric structure is used as a substrate for patch antennas. A meandered-strip line-fed fractal-shape patch antenna is designed and fabricated on a copper-laminated sandwich-structured substrate. Measurement results of this antenna show 44% and 20% of bandwidths with maximum gains of 3.45 dBi and 5.87 dBi for the lower and upper bands, respectively. The half-power beam widths of 104° and 78° have been observed from the measured radiation pattern at the two resonance frequencies 0.9 GHz and 2.5 GHz.

  10. Influence of reinforcement type on the mechanical behavior and fire response of hybrid composites and sandwich structures

    Science.gov (United States)

    Giancaspro, James William

    Lightweight composites and structural sandwich panels are commonly used in marine and aerospace applications. Using carbon, glass, and a host of other high strength fiber types, a broad range of laminate composites and sandwich panels can be developed. Hybrid composites can be constructed by laminating multiple layers of varying fiber types while sandwich panels are manufactured by laminating rigid fiber facings onto a lightweight core. However, the lack of fire resistance of the polymers used for the fabrication remains a very important problem. The research presented in this dissertation deals with an inorganic matrix (Geopolymer) that can be used to manufacture laminate composites and sandwich panels that are resistant up to 1000°C. This dissertation deals with the influence of fiber type on the mechanical behavior and the fire response of hybrid composites and sandwich structures manufactured using this resin. The results are categorized into the following distinct studies. (i) High strength carbon fibers were combined with low cost E-glass fibers to obtain hybrid laminate composites that are both economical and strong. The E-glass fabrics were used as a core while the carbon fibers were placed on the tension face and on both tension and compression faces. (ii) Structural sandwich beams were developed by laminating various types of reinforcement onto the tension and compression faces of balsa wood cores. The flexural behavior of the beams was then analyzed and compared to beams reinforced with organic composite. The effect of core density was evaluated using oak beams reinforced with inorganic composite. (iii) To measure the fire response, balsa wood sandwich panels were manufactured using a thin layer of a fire-resistant paste to serve for fire protection. Seventeen sandwich panels were fabricated and tested to measure the heat release rates and smoke-generating characteristics. The results indicate that Geopolymer can be effectively used to fabricate both

  11. Measurement of shear strength resistance in flexion test on PUR sandwich panels: analysis of difficulties and finite element method simulation

    Directory of Open Access Journals (Sweden)

    J. M. Chillón Moreno

    2017-09-01

    Full Text Available The use of the composite construction elements combining different materials with complementary characteristics, it has spread increasingly. The sandwich panels composed by external metallic sheets that they contributes resistance and core of rigid insulating thermal foam, that provides qualities that improve the thermal comfort inside all kinds of constructions. They are in use in closings and covers that shape the surrounding one of the buildings. Of the different quality controls to which they have to surrender. In this article one proposes an improvement to the indicated one in the procedure for the determination of the resistance to the shear strength, Managing to avoid many anomalous results obtained by the utilization of rigid plates in the supports. Finally, so much the problem observed as the proposed solution, they are modeled and simulate by means of the method of finite elements.

  12. Numerical and Experimental Low-Velocity Impact Behaivor of Sandwich Plates with Viscoelastic Core

    Directory of Open Access Journals (Sweden)

    Soroush Sadeghnejad

    2016-03-01

    Full Text Available A numerical and experimental low-velocity impact behavior of sandwich plates have been presently studied with regard to the compressibility and viscoelasticity features of their cores. Face sheets were assumed to be anisotropic composites or isotropic aluminum materials and a viscoelastic behavior has been considered for core. The boundary conditions are assumed to be simply supported or rigid. Abaqus, as FEM software, and its python script programming feature, have been used to model the specimens. To model hyper-viscoelastic nonlinear behavior of the core, Ogden hyper-foam elasticity and Prony series approach are manipulated. To solve the numerical problem, dynamic explicit solver option with sufficient solving amplitude has been used. Prony series have been used to model the core time-dependent behavior. In conjunction with a simple indentation experiment, FEM used to formulate a novel method for finding the Prony series coefficients. By performing some low-velocity impact experiments, the impact force and displacement of the composite sandwich plates have been investigated. The results indicate that increasing the structural damping increases the contact time and missing energy and decreases the stored energy of the system. The structures with composite face sheets have a minimum ratio of upper face sheet displacement to lower face sheet displacement in comparison to those with the isotropic face sheets. Impact behavior of isotropic face sheet specimens are more flattened than that of the composite face sheets. In addition, the specific energy stored in the sandwich plates with composite face sheets, on different supports, is greater than that stored in the aluminum face sheets.

  13. Application of sandwich honeycomb carbon/glass fiber-honeycomb composite in the floor component of electric car

    Science.gov (United States)

    Sukmaji, I. C.; Wijang, W. R.; Andri, S.; Bambang, K.; Teguh, T.

    2017-01-01

    Nowadays composite is a superior material used in automotive component due to its outstanding mechanical behavior. The sandwich polypropylene honeycomb core with carbon/glass fiber composite skin (SHCG) as based material in a floor component of electric car application is investigated in the present research. In sandwich structure form, it can absorb noise better compare with the conventional material [1]. Also in present paper, Finite Element Analysis (FEA) of SHCG as based material for floor component of the electric car is analyzed. The composite sandwich is contained with a layer uniform carbon fiber and mixing non-uniform carbon-glass fiber in upper and lower skin. Between skins of SHCG are core polypropylene honeycomb that it have good flexibility to form following dies profile. The variables of volume fraction ratio of carbon/glass fiber in SHCG skin are 20/80%, 30/70%, and 50/50%. The specimen of SHCG is tested using the universal testing machine by three points bending method refers to ASTM C393 and ASTM C365. The cross point between tensile strength to the volume fraction the mixing carbon/glass line and ratio cost line are the searched material with good mechanical performance and reasonable cost. The point is 30/70 volume fraction of carbon/glass fiber. The result of the testing experiment is become input properties of model structure sandwich in FEA simulation. FEA simulation approach is conducted to find critical strength and factor of complex safety geometry against varied distributed passenger loads of a floor component the electric car. The passenger loads variable are 80, 100, 150, 200, 250 and 300 kg.

  14. Determination of Peroxide Value of Edible Oils Used in Confectionary, Restaurants and Sandwich Shops in Gorgan in 2011

    Directory of Open Access Journals (Sweden)

    H RahimzadehBarzoki

    2014-05-01

    Conclusion: The findings show that Peroxide value in sandwich and fast food shops, restaurants, and confectionary shop are higher than the standard, so its seems that having educational plan for staff about nutrition and the correct methods of frying food is necessary.

  15. An ELISA using recombinant TmHSP70 for the diagnosis of Taenia multiceps infections in goats.

    Science.gov (United States)

    Wang, Yu; Nie, Huaming; Gu, Xiaobin; Wang, Tao; Huang, Xing; Chen, Lin; Lai, Weimin; Peng, Xuerong; Yang, Guangyou

    2015-09-15

    Infections with the tapeworm Taenia multiceps are problematic for ruminant farming worldwide. Here we develop a novel and rapid method for serodiagnosis of T. multiceps infections via an indirect ELISA (iELISA) that uses a heat shock protein, namely, TmHSP70. We extracted the total RNA of T. multiceps from the protoscoleces of cysts dissected from the brains of infected goats. Subsequently, we successfully amplified, cloned and expressed the TmHSP70 gene in Escherichia coli BL21 (DE3). Western blot analysis showed that the recombinant protein (∼34 kDa molecular weight) was recognized by the coenurosis positive serum. Given these initial, robust immunogenic properties for recombinant TmHSP protein, we assessed the ELISA-based serodiagnostic potential of this gene. The indirect ELISA was then optimized to 2.70 μg/well dilution for antigen and 1:80 dilution for serum,while the cut-off value is 0.446. We report that our novel TmHSP ELISA detected T. multiceps sera with a sensitivity of 1:10240 and a specificity of 83.3% (5/6). In a preliminary application, this assay correctly confirmed T. multiceps infection in 30 infected goats, consistent with the clinical examination. This study has revealed that our novel iELISA, which uses the rTmHSP protein, provides a rapid test for diagnosing coenurosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Sandwich veto detector at COMPASS experiment

    International Nuclear Information System (INIS)

    Sarkar, S.; Dasgupta, S.S.; Calcutta-COMPASS group

    2010-01-01

    This paper presents the newly build Sandwich Detector for 190 GeV hadron run of COMPASS Experiment at CERN. The technical details and the testing procedures are included to highlight the physics objective of the installation. Single electron detection techniques has been developed and used to scale the performance of the detector. This analysis can predict the number of single electrons per MIP at the scintillation detector. (author)

  17. Sandwich-structured hollow fiber membranes for osmotic power generation

    KAUST Repository

    Fu, Feng Jiang; Zhang, Sui; Chung, Neal Tai-Shung

    2015-01-01

    In this work, a novel sandwich-structured hollow fiber membrane has been developed via a specially designed spinneret and optimized spinning conditions. With this specially designed spinneret, the outer layer, which is the most crucial part of the sandwich-structured membrane, is maintained the same as the traditional dual-layer membrane. The inner substrate layer is separated into two layers: (1) an ultra-thin middle layer comprising a high molecular weight polyvinylpyrrolidone (PVP) additive to enhance integration with the outer polybenzimidazole (PBI) selective layer, and (2) an inner-layer to provide strong mechanical strength for the membrane. Experimental results show that a high water permeability and good mechanical strength could be achieved without the expensive post treatment process to remove PVP which was necessary for the dual-layer pressure retarded osmosis (PRO) membranes. By optimizing the composition, the membrane shows a maximum power density of 6.23W/m2 at a hydraulic pressure of 22.0bar when 1M NaCl and 10mM NaCl are used as the draw and feed solutions, respectively. To our best knowledge, this is the best phase inversion hollow fiber membrane with an outer selective PBI layer for osmotic power generation. In addition, this is the first work that shows how to fabricate sandwich-structured hollow fiber membranes for various applications. © 2015 Elsevier B.V.

  18. Sandwich-structured hollow fiber membranes for osmotic power generation

    KAUST Repository

    Fu, Feng Jiang

    2015-11-01

    In this work, a novel sandwich-structured hollow fiber membrane has been developed via a specially designed spinneret and optimized spinning conditions. With this specially designed spinneret, the outer layer, which is the most crucial part of the sandwich-structured membrane, is maintained the same as the traditional dual-layer membrane. The inner substrate layer is separated into two layers: (1) an ultra-thin middle layer comprising a high molecular weight polyvinylpyrrolidone (PVP) additive to enhance integration with the outer polybenzimidazole (PBI) selective layer, and (2) an inner-layer to provide strong mechanical strength for the membrane. Experimental results show that a high water permeability and good mechanical strength could be achieved without the expensive post treatment process to remove PVP which was necessary for the dual-layer pressure retarded osmosis (PRO) membranes. By optimizing the composition, the membrane shows a maximum power density of 6.23W/m2 at a hydraulic pressure of 22.0bar when 1M NaCl and 10mM NaCl are used as the draw and feed solutions, respectively. To our best knowledge, this is the best phase inversion hollow fiber membrane with an outer selective PBI layer for osmotic power generation. In addition, this is the first work that shows how to fabricate sandwich-structured hollow fiber membranes for various applications. © 2015 Elsevier B.V.

  19. ELISA Cut-off Point for the Diagnosis of Human Brucellosis; a Comparison with Serum Agglutination Test

    Directory of Open Access Journals (Sweden)

    Anahita Sanaei Dashti

    2012-03-01

    Full Text Available Background: Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum agglutination test (SAT is the most-widely used test for diagnosing brucellosis. The enzyme linked immunosorbent assay (ELISA can also determine specific antibody classes against brucella. It is a sensitive, simple and rapid test, which could be an acceptable alternative to SAT with fewer limitations, however, like any other new test it should be further evaluated and standardized for various populations. This study was planned to determine an optimal cut-off point, for ELISA which would offer maximum sensitivity and specificity for the test when compared to SAT.Methods: Four hundred and seven patients with fever and other compatible symptoms of brucellosis were enrolled in the study. Serum agglutination test, 2-Mercaptoethanol test, and ELISA were performed on their sera. Results: The cut-off point of 53 IU/ml of ELISA-IgG yielded the maximal sensitivity and specificity comparing to the other levels of ELISA-IgG, and was considered the best cut off-point of ELISA-IgG to diagnose acute brucellosis. At this cut-off, the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were 84.09%, 85.38%, 62.20, 94.90, 5.75, 0.18, respectively.Conclusion: The best cut-off point of ELISA-IgG is 53 IU/ml, which yields the maximal sensitivity and specificity to diagnose acute brucellosis.

  20. Improved detection of canine Angiostrongylus vasorum infection using real-time PCR and indirect ELISA.

    Science.gov (United States)

    Jefferies, Ryan; Morgan, Eric R; Helm, Jenny; Robinson, Matthew; Shaw, Susan E

    2011-12-01

    This study reports the development of a real-time PCR assay and an indirect ELISA to improve on current detection of canine Angiostrongylus vasorum infection. A highly specific fluorescent probe-based, real-time PCR assay was developed to target the A. vasorum second internal transcribed spacer region and detected DNA in EDTA blood, lung tissue, broncho-alveolar larvage fluid, endotracheal mucus, pharyngeal swabs and faecal samples. PCR was fast (∼1 h), highly efficient when using EDTA blood samples, consistently detected a single molecule of parasite DNA and did not amplify DNA from other parasitic nematodes or definitive host species. An indirect ELISA was also developed using the soluble protein fraction from adult A. vasorum worms. Some cross-reactive antigen recognition was observed when tested against sera from dogs infected with Crenosoma vulpis (n = 8), Toxocara canis (n = 5) and Dirofilaria immitis (n = 5). This was largely overcome by setting the cut-off for a positive result at an appropriately high level. Field evaluation of the real-time PCR and ELISA was conducted by testing sera and EDTA blood from dogs with suspected A. vasorum infection (n = 148) and compared with the Baermann's larval migration test in faeces. Thirty-one dogs were positive by at least one test. Of these, 20 (65%) were detected by the Baermann method, 18 (58%) by blood PCR, 24 (77%) by ELISA and 28 (90%) by blood PCR and ELISA together. Combined testing using real-time PCR and ELISA therefore improved the detection rate of A. vasorum infection and holds promise for improved clinical diagnosis and epidemiological investigation.

  1. Predicting the cross-reactivities of polycyclic aromatic hydrocarbons in ELISA by regression analysis and CoMFA methods

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yan-Feng; Dai, Shu-Gui [College of Environmental Science and Engineering, Nankai University, Key Laboratory for Pollution Process and Environmental Criteria of Ministry of Education, Tianjin (China); Ma, Yi [College of Chemistry, Nankai University, Institute of Elemento-Organic Chemistry, Tianjin (China); Gao, Zhi-Xian [Institute of Hygiene and Environmental Medicine, Tianjin (China)

    2010-07-15

    Immunoassays have been regarded as a possible alternative or supplement for measuring polycyclic aromatic hydrocarbons (PAHs) in the environment. Since there are too many potential cross-reactants for PAH immunoassays, it is difficult to determine all the cross-reactivities (CRs) by experimental tests. The relationship between CR and the physical-chemical properties of PAHs and related compounds was investigated using the CR data from a commercial enzyme-linked immunosorbent assay (ELISA) kit test. Two quantitative structure-activity relationship (QSAR) techniques, regression analysis and comparative molecular field analysis (CoMFA), were applied for predicting the CR of PAHs in this ELISA kit. Parabolic regression indicates that the CRs are significantly correlated with the logarithm of the partition coefficient for the octanol-water system (log K{sub ow}) (r{sup 2}=0.643, n=23, P<0.0001), suggesting that hydrophobic interactions play an important role in the antigen-antibody binding and the cross-reactions in this ELISA test. The CoMFA model obtained shows that the CRs of the PAHs are correlated with the 3D structure of the molecules (r{sub cv}{sup 2}=0.663, r{sup 2}=0.873, F{sub 4,32}=55.086). The contributions of the steric and electrostatic fields to CR were 40.4 and 59.6%, respectively. Both of the QSAR models satisfactorily predict the CR in this PAH immunoassay kit, and help in understanding the mechanisms of antigen-antibody interaction. (orig.)

  2. Radiolinja, Vodafone või Elisa

    Index Scriptorium Estoniae

    2004-01-01

    Jüri Kaljundi, Tarvo Ulejev ning Anne Mere vastavad küsimusele, kas Radiolinja peaks jätma alles olemasoleva nime, võtma nimeks Soomes peagi Radiolinjat asendama hakkava Elisa või rahvusvaheliselt tuntud kaubamärgi Vodafone

  3. Effects of Core Softness and Bimodularity of Fibreglass Layers on Flexural Stiffness of Polymer Sandwich Structures

    Directory of Open Access Journals (Sweden)

    Šuba Oldřich

    2017-01-01

    Full Text Available This paper deals with the study of the flexural stiffness of the sandwich structures based on fibreglass and polymeric foams. The influence of geometrical and material parameters on the resulting effective flexural stiffness of the sandwich structure is being studied experimentally, analytically and by using FEM models. The effective modulus of elasticity of the sandwich-structured element is being studied and its theoretical and model dependencies on the flexibility of the foam core and bimodularity of the fibreglass layers are being investigated. The achieved results are compared with the experimentally observed values. This study shows that it is necessary to pay special attention to the issue of flexural stiffness of the walls when designing sandwich shell products in order to prevent possible failures in the practical applications of these types of structures.

  4. Size-dependent free vibration and dynamic analyses of piezo-electro-magnetic sandwich nanoplates resting on viscoelastic foundation

    Science.gov (United States)

    Arefi, Mohammad; Zenkour, Ashraf M.

    2017-09-01

    In this paper, size-dependent free vibration analysis of a sandwich nanoplate is presented. The sandwich nanoplate is including an elastic nano core and two piezo-electro-magnetic face-sheets as sensor and actuator actuated by electric and magnetic potentials. The sandwich nanoplate is resting on visco-Pasternak's foundation. Hamilton's principle is employed to derive the governing equations of motion based on Kirchhoff plate and nonlocal elasticity theory. The numerical results are presented to study the influence of important parameters of the problem such as applied electric and magnetic potentials, nonlocal parameter and visco-Pasternak's parameters. Furthermore, the influence of various boundary conditions is discussed on the vibration characteristics of the sandwich nanoplate.

  5. Development of a blocking ELISA for detection of Mycoplasma hyopneumoniae infection based on a monoclonal antibody against protein P65.

    Science.gov (United States)

    Liu, Maojun; DU, Gaimei; Zhang, Yue; Wu, Yuzi; Wang, Haiyan; Li, Bin; Bai, Yun; Feng, Zhixin; Xiong, Qiyan; Bai, Fangfang; Browning, Glenn F; Shao, Guoqing

    2016-09-01

    Mycoplasma hyopneumoniae causes porcine enzootic pneumonia, an economically important disease of swine. A more sensitive and reliable method for detection of serum antibodies is needed for epidemiological investigations and to evaluate the effect of immunization. We expressed the M. hyopneumoniae protein P65 in Escherichia coli and produced a monoclonal antibody (mAb) that bound specifically to recombinant P65. Using this mAb, a blocking enzyme linked immunosorbent assay (ELISA) was developed. The blocking ELISA had similar specificity to and sensitivity with the commercial ELISA produced by IDEXX. Thus, this blocking ELISA is a useful test for serological confirmation of M. hyopneumoniae infection.

  6. Enhanced detection levels in a semi-automated sandwich ...

    African Journals Online (AJOL)

    A peptide nucleic acid (PNA) signal probe was tested as a replacement for a typical DNA oligonucleotidebased signal probe in a semi-automated sandwich hybridisation assay designed to detect the harmful phytoplankton species Alexandrium tamarense. The PNA probe yielded consistently higher fluorescent signal ...

  7. Performance improvement of organic thin film transistors by using active layer with sandwich structure

    Science.gov (United States)

    Ni, Yao; Zhou, Jianlin; Kuang, Peng; Lin, Hui; Gan, Ping; Hu, Shengdong; Lin, Zhi

    2017-08-01

    We report organic thin film transistors (OTFTs) with pentacene/fluorinated copper phthalo-cyanine (F16CuPc)/pentacene (PFP) sandwich configuration as active layers. The sandwich devices not only show hole mobility enhancement but also present a well control about threshold voltage and off-state current. By investigating various characteristics, including current-voltage hysteresis, organic film morphology, capacitance-voltage curve and resistance variation of active layers carefully, it has been found the performance improvement is mainly attributed to the low carrier traps and the higher conductivity of the sandwich active layer due to the additional induced carriers in F16CuPc/pentacene. Therefore, using proper multiple active layer is an effective way to gain high performance OTFTs.

  8. Smart FRP Composite Sandwich Bridge Decks in Cold Regions

    Science.gov (United States)

    2011-07-01

    In this study, new and integrated Smart honeycomb Fiber-Reinforced Polymer (S-FRP) : sandwich materials for various transportation construction applications, with particular emphasis : on highway bridge decks in cold regions, were developed and teste...

  9. Anomalous photoluminescence thermal quenching of sandwiched single layer MoS_2

    KAUST Repository

    Tangi, Malleswararao

    2017-09-22

    We report an unusual thermal quenching of the micro-photoluminescence (µ-PL) intensity for a sandwiched single-layer (SL) MoS2. For this study, MoS2 layers were chemical vapor deposited on molecular beam epitaxial grown In0.15Al0.85N lattice matched templates. Later, to accomplish air-stable sandwiched SL-MoS2, a thin In0.15Al0.85N cap layer was deposited on the MoS2/In0.15Al0.85N heterostructure. We confirm that the sandwiched MoS2 is a single layer from optical and structural analyses using µ-Raman spectroscopy and scanning transmission electron microscopy, respectively. By using high-resolution X-ray photoelectron spectroscopy, no structural phase transition of MoS2 is noticed. The recombination processes of bound and free excitons were analyzed by the power-dependent µ-PL studies at 77 K and room temperature (RT). The temperature-dependent micro photoluminescence (TDPL) measurements were carried out in the temperature range of 77 – 400 K. As temperature increases, a significant red-shift is observed for the free-exciton PL peak, revealing the delocalization of carriers. Further, we observe unconventional negative thermal quenching behavior, the enhancement of the µ-PL intensity with increasing temperatures up to 300K, which is explained by carrier hopping transitions that take place between shallow localized states to the band-edges. Thus, this study renders a fundamental insight into understanding the anomalous thermal quenching of µ-PL intensity of sandwiched SL-MoS2.

  10. Anomalous photoluminescence thermal quenching of sandwiched single layer MoS_2

    KAUST Repository

    Tangi, Malleswararao; Shakfa, Mohammad Khaled; Mishra, Pawan; Li, Ming-Yang; Chiu, Ming-Hui; Ng, Tien Khee; Li, Lain-Jong; Ooi, Boon S.

    2017-01-01

    We report an unusual thermal quenching of the micro-photoluminescence (µ-PL) intensity for a sandwiched single-layer (SL) MoS2. For this study, MoS2 layers were chemical vapor deposited on molecular beam epitaxial grown In0.15Al0.85N lattice matched templates. Later, to accomplish air-stable sandwiched SL-MoS2, a thin In0.15Al0.85N cap layer was deposited on the MoS2/In0.15Al0.85N heterostructure. We confirm that the sandwiched MoS2 is a single layer from optical and structural analyses using µ-Raman spectroscopy and scanning transmission electron microscopy, respectively. By using high-resolution X-ray photoelectron spectroscopy, no structural phase transition of MoS2 is noticed. The recombination processes of bound and free excitons were analyzed by the power-dependent µ-PL studies at 77 K and room temperature (RT). The temperature-dependent micro photoluminescence (TDPL) measurements were carried out in the temperature range of 77 – 400 K. As temperature increases, a significant red-shift is observed for the free-exciton PL peak, revealing the delocalization of carriers. Further, we observe unconventional negative thermal quenching behavior, the enhancement of the µ-PL intensity with increasing temperatures up to 300K, which is explained by carrier hopping transitions that take place between shallow localized states to the band-edges. Thus, this study renders a fundamental insight into understanding the anomalous thermal quenching of µ-PL intensity of sandwiched SL-MoS2.

  11. Evaluation of serum and milk ELISAs for paratuberculosis in Danish dairy cattle

    DEFF Research Database (Denmark)

    Klausen, Joan; Huda, A.; Ekeroth, Lars

    2003-01-01

    concurrently from six dairy herds infected with MAP and from two dairy herds without history of infection with MAP. A cut-off value of 7 OD% was used in the ELISAs. At this cut-off value, all six culture-positive herds were positive in the serum ELISA but one was negative in the milk ELISA. All six culture......-positive herds were positive in the CFT. In the two culture-negative herds, the serum and the milk ELISA deemed all serum samples negative at this cut-off value, whereas four serum samples from one of these herds were positive in the CFT. The highest cut-off value enabling the milk ELISA to record all six...... culture-positive herds as positive was 4 OD%. The highest cut-off value enabling the serum ELISA to record all six culture-positive herds as positive was 17 OD%. Individual-sample relative sensitivities of the ELISAs ranged from 49 to 64% and relative specificities were 80-96% at the cut-off values of 4...

  12. Enhancing Photocatalytic Activity on (MnO@TNTAs):Mn2+ with a Hierarchical Sandwich-Like Nanostructure via a Two-Step Procedure

    Science.gov (United States)

    Kong, Junhan; Zhang, Wei; Zhang, Yubo; Xia, Minghao; Wu, Xiuling; Wang, Yongqian

    2018-02-01

    Several semiconductor nanomaterial devices are increasingly being applied in a variety of fields, especially in the treating of environmental pollutants. We have fabricated (MnO@TNTAs):Mn2+ with sandwich-like nanostructures composed of TiO2 nanotube arrays (TNTAs), Mn-doped TNTAs and MnO. The experimental procedure was a two-step synthesis: first, using anodic oxidation methods and then hydrothermal methods. We carried out many characterizations of the "sandwiches" in the nanoscale. From the field emission scanning electron microscopy images we found nanofibers lying on the highly-ordered nanotube arrays. The diameter of the nanotubes was about 50 nm but the size of the nanofibers varied. Energy dispersive spectroscopy demonstrated that the nanofibers contained a manganese element and x-ray diffraction patterns showed the peak of the manganosite phase. From ultraviolet-visible light spectra, it was found that the nanostructures had strong absorption activities under both ultraviolet and visible light radiation, while pure TNTAs had absorption only under ultraviolet light. The photodegradation experiments proved that the sandwich-like nanostructures had an excellent photocatalytic activity (92.5% after 240 min), which was a great improvement compared with pure TNTAs. In this way, the structures as a device at the nanoscale have a huge potential in controlling environmental pollution.

  13. Failure of uniformly compression loaded debond damaged sandwich panels — An experimental and numerical study

    DEFF Research Database (Denmark)

    Moslemian, Ramin; Quispitupa, Amilcar; Berggreen, Christian

    2012-01-01

    This paper deals with the failure of compression-loaded sandwich panels with an implanted circular face/core debond. Uniform compression tests were conducted on intact sandwich panels with three different types of core material (H130, H250 and PMI) and on similar panels with circular face...

  14. A multi-purpose ultrasonic streaming mixer for integrated magnetic bead ELISAs

    International Nuclear Information System (INIS)

    Brandhoff, Lukas; Lang, Walter; Vellekoop, Michael J; Zirath, Helene; Peham, Johannes; Wiesinger-Mayr, Herbert; Salas, Mariugenia; Haller, Anna; Spittler, Andreas; Schnetz, Guntram

    2015-01-01

    We present an ultrasonic streaming mixer for disposable and on-chip magnetic bead ELISAs. The ultrasonic transducer is placed at system-level to keep cost per chip as low as possible, and is coupled to the chip by means of a solid ultrasonic horn. The system provides mixing of liquids, as well as dispersion of the superparamagnetic beads in the ELISA. Additionally it can be used clean the chamber surface from nonspecifically bound proteins during the washing steps in the ELISA protocol. Using our system the time for the ELISA protocol has been greatly reduced down to 30 min. (paper)

  15. Polyisocyanurate systems for insulating and sandwich elements; Polyisocyanurat-Systeme fuer Daemm- und Sandwichelemente

    Energy Technology Data Exchange (ETDEWEB)

    Malotki, P. von [Elastogran GmbH, Lemfoerde (Germany)

    2000-07-01

    PUR rigid foam plates are laminated with flexible Al films, paper or glass non-wovens, or may be processed into sandwich elements with metallic top-layers via coil-coating. Dependence of heat insulation efficiency, dimensional stability and fire behavior of the foam on chemical composition and the blowing agents is considered and compared with polyisocyanurate foams. Recipes for the production of PIR heat insulation elements and sandwich elements are given.

  16. ELISA-PLA: A novel hybrid platform for the rapid, highly sensitive and specific quantification of proteins and post-translational modifications.

    Science.gov (United States)

    Tong, Qing-He; Tao, Tao; Xie, Li-Qi; Lu, Hao-Jie

    2016-06-15

    Detection of low-abundance proteins and their post-translational modifications (PTMs) remains a great challenge. A conventional enzyme-linked immunosorbent assay (ELISA) is not sensitive enough to detect low-abundance PTMs and suffers from nonspecific detection. Herein, a rapid, highly sensitive and specific platform integrating ELISA with a proximity ligation assay (PLA), termed ELISA-PLA, was developed. Using ELISA-PLA, the specificity was improved by the simultaneous and proximate recognition of targets through multiple probes, and the sensitivity was significantly improved by rolling circle amplification (RCA). For GFP, the limit of detection (LOD) was decreased by two orders of magnitude compared to that of ELISA. Using site-specific phospho-antibody and pan-specific phospho-antibody, ELISA-PLA was successfully applied to quantify the phosphorylation dynamics of ERK1/2 and the overall tyrosine phosphorylation level of ERK1/2, respectively. ELISA-PLA was also used to quantify the O-GlcNAcylation of AKT, c-Fos, CREB and STAT3, which is faster and more sensitive than the conventional immunoprecipitation and western blotting (IP-WB) method. As a result, the sample consumption of ELISA-PLA was reduced 40-fold compared to IP-WB. Therefore, ELISA-PLA could be a promising platform for the rapid, sensitive and specific detection of proteins and PTMs. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. The use of polyvinyl alcohol glutaraldehyde as solid-phase in ELISA for plague

    Directory of Open Access Journals (Sweden)

    Aureci Maria Araujo

    1996-04-01

    Full Text Available Discs of polyvinyl alcohol cross-linked with glutaraldehyde were synthesized under acid catalysis (H2SO4. Then, the antigen F1 purified from Yersinia pestis was covalently linked to this modified polymer. Afterwards, an enzyme-linked immunosorbent assay (ELISA was established for the diagnosis of plague in rabbit and human. The best conditions for the method were achieved by using 1.3 ¼g of F1 prepared in 0.067 M phosphate buffer, pH 7.2, containing 1 M NaCl (PBS; anti-IgG peroxidase conjugate diluted 6,000 times and as a blocking agent 3% w/v skim milk in PBS. The titration of positive rabbit serum according to this procedure detected antibody concentrations up to 1:12,800 times. The present method, the conventional ELISA and passive haemagglutination assay are compared.

  18. A Study on Flexural Properties of Sandwich Structures with Fiber/Metal Laminate Face Sheets

    Science.gov (United States)

    Dariushi, S.; Sadighi, M.

    2013-10-01

    In this work, a new family of sandwich structures with fiber metal laminate (FML) faces is investigated. FMLs have benefits over both metal and fiber reinforced composites. To investigate the bending properties of sandwich beams with FML faces and compare with similar sandwich beams with fibrous composite faces, 6 groups of specimen with different layer arrangements were made and tested. Results show that FML faces have good resistance against transverse local loads and minimize stress concentration and local deformations of skin and core under the loading tip. In addition, FML faces have a good integrity even after plateau region of foam cores and prevent from catastrophic failures, which cannot be seen in fibrous composite faces. Also, FML faces are lighter than metal faces and have better connection with foam cores. Sandwich beams with FML faces have a larger elastic region because of simultaneous deformation of top and bottom faces and larger failure strain thanks to good durability of FMLs. A geometrical nonlinear classical theory is used to predict force-deflection behavior. In this model an explicit formula between symmetrical sandwich beams deflections and applied force which can be useful for designers, is derived. Good agreement is obtained between the analytical predictions and experimental results. Also, analytical results are compared with small deformation solution in a parametric study, and the effects of geometric parameters on difference between linear and nonlinear results are discussed.

  19. Failure modes of composite sandwich beams

    OpenAIRE

    Gdoutos E.; Daniel I.M.

    2008-01-01

    A thorough investigation of failure behavior of composite sandwich beams under three-and four-point bending was undertaken. The beams were made of unidirectional carbon/epoxy facings and a PVC closed-cell foam core. The constituent materials were fully characterized and in the case of the foam core, failure envelopes were developed for general two-dimensional states of stress. Various failure modes including facing wrinkling, indentation failure and core failure were observed and compared wit...

  20. Fatigue Debond Growth in Sandwich Structures Loaded in Mixed Mode Bending (MMB)

    DEFF Research Database (Denmark)

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, Leif A.

    2008-01-01

    Static and cyclic debond growth in sandwich specimens loaded in mixed mode bending (MMB) is examined. The MMB sandwich specimens were manufactured using H100 PVC foam core and E-glass/polyester non-crimp quadro-axial [0/45/90/-45]s DBLT-850 face sheets. Static test were performed to determine...... the fracture toughness of the debonded sandwich specimens at different mixed mode loadings. The mixed mode ratio (mode I to mode II) was controlled by changing the lever arm distance of the MMB test rig. Compliance technique and visual inspection was employed to measure the crack length during fatigue. Fatigue...... tests were performed at 90% of the static fracture toughness at a loading ratio of R=0.1. Fatigue results revealed higher debond crack growth rates when the lever arm distance was increased. For some specimens, the crack propagated just below the face/core interface in the foam core and for others...

  1. Examination of Sandwich Materials Using Air-Coupled Ultrasonics

    DEFF Research Database (Denmark)

    Borum, K.K.; Berggreen, Carl Christian

    2004-01-01

    The air-coupled ultrasonic techniques have been improved drastically in recent years. Better equipment has made this technique much more useful. This paper focuses on the examination of sandwich materials used in naval ships. It is more convenient to be able to make the measurements directly...

  2. Jatobal virus antigenic characterization by ELISA and neutralization test using EIA as indicator, on tissue culture

    Directory of Open Access Journals (Sweden)

    Luiz Tadeu M. Figueiredo

    1988-06-01

    Full Text Available A virus antigenic characterization methodology using an indirect method of antibody detection ELISA with virus-infected cultured cells as antigen and a micro virus neutralisation test using EIA (NT-EIA as an aid to reading were used for antigenic characterization of Jatobal (BeAn 423380. Jatobal virus was characterized as a Bunyaviridae, Bunyavirus genus, Simbu serogroup virus. ELISA using infected cultured cells as antigen is a sensitive and reliable method for identification of viruses and has many advantages over conventional antibody capture ELISA's and other tests: it eliminates solid phase coating with virus and laborious antigen preparation; it permits screening of large numbers of virus antisera faster and more easily than by CF, HAI, or plaque reduction NT. ELISA and NT using EIA as an aid to reading can be applicable to viruses which do not produce cytopathogenic effect. Both techniques are applicable to identification of viruses which grow in mosquito cells.A caracterização antigênica do vírus Jatobal (BeAn 423380 foi efetuada utilizando uma técnica de ELISA para deteccão de anticorpos que utiliza culturas celulares infectadas como antígeno e um micro teste de neutralização para vírus que utiliza o método imunoenzimático como auxiliar para a leitura dos resultados (NT-EIA. O vírus Jatobal foi caracterizado como um Bunyaviridae, gênero Bunyavirus, pertencente ao sorogrupo Simbu. A técnica de ELISA, utilizando culturas celulares infectadas como antígeno, trata-se de método sensível e confiável na identificação de agentes virais, possuindo muitas vantagens sobre ELISA convencionais e outros testes: elimina a preparação laboriosa de antígenos para o revestimento em fase sólida; permite que se teste de forma mais rápida e fácil que por CF, HAI e neutralização por redução de plaques um grande número de antisoros de vírus. ELISA e NT-EIA podem ser utilizados para a classificação de vírus que não produzem

  3. Biomimetic ELISA detection of malachite green based on molecularly imprinted polymer film.

    Science.gov (United States)

    Li, Lu; Peng, Ai-Hong; Lin, Zheng-Zhong; Zhong, Hui-Ping; Chen, Xiao-Mei; Huang, Zhi-Yong

    2017-08-15

    A highly selective and sensitive enzyme-linked immunosorbent assay (ELISA) was developed for the detection of malachite green (MG) using a molecularly imprinted polymer (MIP) film as bionic antibody. The MIP film, based on the self-polymerization of dopamine, was fabricated on the surfaces of a 96-well microplate. It showed specific recognition for MG in aqueous solution. A direct competitive ELISA method was established with the sensitivity reaching 10.31μgL -1 and the detection limit being 0.3μgL -1 . The cross-reactivity of two structural analogues to MG was less than 10%. The average recovery tested by MG standard spiking was 88.8% for bass and 90.4% for water, and the relative standard deviations were less than 3.6%. All the above results indicated that the developed method could be used to detect MG in fish and water samples rapidly, specifically and accurately. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Rationalizing and advancing the 3-MPBA SERS sandwich assay for rapid detection of bacteria in environmental and food matrices.

    Science.gov (United States)

    Pearson, Brooke; Mills, Alexander; Tucker, Madeline; Gao, Siyue; McLandsborough, Lynne; He, Lili

    2018-06-01

    Bacterial foodborne illness continues to be a pressing issue in our food supply. Rapid detection methods are needed for perishable foods due to their short shelf lives and significant contribution to foodborne illness. Previously, a sensitive and reliable surface-enhanced Raman spectroscopy (SERS) sandwich assay based on 3-mercaptophenylboronic acid (3-MBPA) as a capturer and indicator molecule was developed for rapid bacteria detection. In this study, we explored the advantages and constraints of this assay over the conventional aerobic plate count (APC) method and further developed methods for detection in real environmental and food matrices. The SERS sandwich assay was able to detect environmental bacteria in pond water and on spinach leaves at higher levels than the APC method. In addition, the SERS assay appeared to have higher sensitivity to quantify bacteria in the stationary phase. On the other hand, the APC method was more sensitive to cell viability. Finally, a method to detect bacteria in a challenging high-sugar juice matrix was developed to enhance bacteria capture. This study advanced the SERS technique for real applications in environment and food matrices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. A novel electrochemical aptamer-antibody sandwich assay for lysozyme detection.

    Science.gov (United States)

    Ocaña, Cristina; Hayat, Akhtar; Mishra, Rupesh; Vasilescu, Alina; del Valle, Manel; Marty, Jean-Louis

    2015-06-21

    In this paper, we have reported a novel electrochemical aptamer-antibody based sandwich biosensor for the detection of lysozyme. In the sensing strategy, an anti-lysozyme aptamer was immobilized onto the carbon electrode surface by covalent binding via diazonium salt chemistry. After incubating with a target protein (lysozyme), a biotinylated antibody was used to complete the sandwich format. The subsequent additions of avidin-alkaline phosphatase as an enzyme label, and a 1-naphthyl phosphate substrate (1-NPP) allowed us to determine the concentration of lysozyme (Lys) via Differential Pulse Voltammetry (DPV) of the generated enzyme reaction product, 1-naphthol. Using this strategy, a wide detection range from 5 fM to 5 nM was obtained for a target lysozyme, with a detection limit of 4.3 fM. The control experiments were carried out by using bovine serum albumin (BSA), cytochrome c and casein. The results showed that the proposed biosensor had good specificity, stability and reproducibility for lysozyme analysis. In addition, the biosensor was applied for detecting lysozyme in spiked wine samples, and very good recovery rates were obtained in the range from 95.2 to 102.0% for lysozyme detection. This implies that the proposed sandwich biosensor is a promising analytical tool for the analysis of lysozyme in real samples.

  6. Effect of a magnetic field on the excess resistance of SNS sandwiches

    International Nuclear Information System (INIS)

    Logvenov, G.Y.; Ryazanov, V.V.

    1983-01-01

    The contribution of superconducting plates to the resistance of Ta--Cu--Ta sandwiches in the presence of a magnetic field of up to 170 Ge is investigated. Near the superconducting transition temperature T/sub c/H, the Ta used was in a mixed (vortical) state. It is shown that the presence of gradients of the order parameter near the Abrikosov vortices appreciably changes the penetration depth of a longitudinal electric field into the superconductor and leads to a corresponding change in the excess resistance of SNS sandwiches

  7. Dot-ELISA affinity test: an easy, low-cost method to estimate binding activity of monoclonal antibodies

    Czech Academy of Sciences Publication Activity Database

    Svobodová, Z.; Jankovičová, B.; Horák, Daniel; Bílková, Z.

    2013-01-01

    Roč. 4, č. 3 (2013), 1000168_1-1000168_5 ISSN 2155-9872 R&D Projects: GA MŠk 7E12053; GA MŠk 7E09109 EU Projects: European Commission(XE) 246513 - NADINE; European Commission(XE) 228980 - CAMINEMS Institutional support: RVO:61389013 Keywords : dot-ELISA * affinity * monoclonal antibody Subject RIV: CD - Macromolecular Chemistry

  8. Laser welded steel sandwich panel bridge deck development : finite element analysis and stake weld strength tests.

    Science.gov (United States)

    2009-09-01

    This report summarizes the analysis of laser welded steel sandwich panels for use in bridge structures and : static testing of laser stake welded lap shear coupons. Steel sandwich panels consist of two face sheets : connected by a relatively low-dens...

  9. Evaluation of dengue NS1 antigen rapid tests and ELISA kits using clinical samples.

    Directory of Open Access Journals (Sweden)

    Subhamoy Pal

    Full Text Available Early diagnosis of dengue virus (DENV infection can improve clinical outcomes by ensuring close follow-up, initiating appropriate supportive therapies and raising awareness to the potential of hemorrhage or shock. Non-structural glycoprotein-1 (NS1 has proven to be a useful biomarker for early diagnosis of dengue. A number of rapid diagnostic tests (RDTs and enzyme-linked immunosorbent assays (ELISAs targeting NS1 antigen (Ag are now commercially available. Here we evaluated these tests using a well-characterized panel of clinical samples to determine their effectiveness for early diagnosis.Retrospective samples from South America were used to evaluate the following tests: (i "Dengue NS1 Ag STRIP" and (ii "Platelia Dengue NS1 Ag ELISA" (Bio-Rad, France, (iii "Dengue NS1 Detect Rapid Test (1st Generation" and (iv "DENV Detect NS1 ELISA" (InBios International, United States, (v "Panbio Dengue Early Rapid (1st generation" (vi "Panbio Dengue Early ELISA (2nd generation" and (vii "SD Bioline Dengue NS1 Ag Rapid Test" (Alere, United States. Overall, the sensitivity of the RDTs ranged from 71.9%-79.1% while the sensitivity of the ELISAs varied between 85.6-95.9%, using virus isolation as the reference method. Most tests had lower sensitivity for DENV-4 relative to the other three serotypes, were less sensitive in detecting secondary infections, and appeared to be most sensitive on Day 3-4 post symptom onset. The specificity of all evaluated tests ranged from 95%-100%.ELISAs had greater overall sensitivity than RDTs. In conjunction with other parameters, the performance data can help determine which dengue diagnostics should be used during the first few days of illness, when the patients are most likely to present to a clinic seeking care.

  10. Influence of the inter-layer adhesion on the structural strength of sandwich pipes; Influencia da adesao entre camadas na resistencia estrutural de dutos sanduiche

    Energy Technology Data Exchange (ETDEWEB)

    Castello, Xavier; Estefen, Segen [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Oceanica

    2005-07-01

    Sandwich pipes composed of two steel layers separated by a polypropylene annulus can be used for the transport of oil and gas in deep waters, combining high structural resistance with thermal insulation in order to prevent blockage by paraffin and hydrates. In this work, sandwich pipes with typical inner diameters of those employed in the offshore production are analyzed numerically regarding to the influence of the inter-layer adhesion of steel pipes and polymer on the limit strength under external pressure and longitudinal bending as well as the bending and straightening process representative of the reeling installation method. The numerical model incorporates geometric and material non-linearity, which had been based on previous works of the authors. Tests of specimens under tension and segments of sandwich pipes are carried through to evaluate the maximum shear stresses of the interfaces metal-polymer. The adhesion is modeled by contact adopting a maximum shear stress value to allow the relative displacement between the layers. It was observed that the structural resistance of the sandwich pipe is strongly dependent on the shear stress acting at the interface, occurring the collapse of the pipe when the maximum shear stress is reached. The results obtained are analyzed to determine the minimum shear strength at the union which provides adequate structural resistance for the sandwich pipe under representative conditions of the installation and operation loading phases. (author)

  11. Homologous ELISA for detection of oligomeric human TNF: properties of the assay.

    Science.gov (United States)

    Petyovka, N; Lyach, L; Voitenok, N N

    1995-10-26

    In order to quantify oligomeric human tumor necrosis factor-alpha (TNF), we have developed a sensitive homologous enzyme-linked immunosorbent assay (Hm-ELISA) using the same monoclonal antibody (MoAb) for both solid and liquid phase. Different anti-TNF MoAb have been compared in terms of their efficacy in the Hm-ELISA, affinity, neutralization capacity and epitope specificity. The data suggest, that effectiveness in the Hm-ELISA may represent a novel characteristic of MoAb. Of the MoAbs tested, 5 N was capable of recognizing oligomeric TNF in the Hm-ELISA with a detection limit of 15 pg/ml. Furthermore, using Hm-ELISA against human TNF, interleukin-8 (IL-8) and lymphotoxin, we have demonstrated that these cytokines are oligomeric in physiological solutions, but are converted into monomeric forms in the presence of the non-ionic detergent Tween 20. High salt buffer was employed to abrogate a nonspecific false positive reaction in the Hm-ELISA found in nearly half of the plasma samples obtained from healthy subjects. Finally, a good correlation between the Hm-ELISA and the L929 bioassay was observed for natural and recombinant TNF measured in human plasma.

  12. Suppression of MMP activity in bovine cartilage explants cultures has little if any effect on the release of aggrecanase-derived aggrecan fragments

    Directory of Open Access Journals (Sweden)

    Sondergaard Bodil-Cecilie

    2009-12-01

    Full Text Available Abstract Background Progressive loss of articular cartilage is a central hallmark in many joint disease, however, the relative importance of individual proteolytic pathways leading to cartilage erosion is at present unknown. We therefore investigated the time-dependant release ex vivo of MMP- and aggrecanase-derived fragments of aggrecan and type II collagen into the supernatant of bovine cartilage explants cultures using neo-epitope specific immunoassays, and to associate the release of these fragments with the activity of proteolytic enzymes using inhibitors. Findings Bovine cartilage explants were cultured in the presence or absence of the catabolic cytokines oncostatin M (OSM and tumor necrosis factor alpha (TNFα. In parallel, explants were co-cultured with protease inhibitors such as GM6001, TIMP1, TIMP2 and TIMP3. Fragments released into the supernatant were determined using a range of neo-epitope specific immunoassays; (1 sandwich 342FFGVG-G2 ELISA, (2 competition NITEGE373ELISA (3 sandwich G1-NITEGE373 ELISA (4 competition 374ARGSV ELISA, and (5 sandwich 374ARGSV-G2 ELISA all detecting aggrecan fragments, and (6 sandwich CTX-II ELISA, detecting C-telopeptides of type II collagen. We found that (1 aggrecanase-derived aggrecan fragments are released in the early (day 2-7 and mid phase (day 9-14 into the supernatant from bovine explants cultures stimulated with catabolic cytokines, (2 the release of NITEGE373 neo-epitopes are delayed compared to the corresponding 374ARGSV fragments, (3 the MMP inhibitor GM6001 did not reduce the release of aggrecanase-derived fragment, but induced a further delay in the release of these fragments, and finally (4 the MMP-derived aggrecan and type II collagen fragments were released in the late phase (day 16-21 only. Conclusion Our data support the model, that aggrecanases and MMPs act independently in the processing of the aggrecan molecules, and furthermore that suppression of MMP-activity had little if

  13. Research And Practice: Quantification Of Raw And Heat-Treated Cow Milk in Sheep Milk, Cheese And Bryndza By ELISA Method

    Directory of Open Access Journals (Sweden)

    Lucia Zeleňáková

    2016-01-01

    Full Text Available The aim of this study was to test the reliability of commercial ELISA tests (RC-bovino within raw and heat treated cow milk detection in sheep milk and cheese in order to obtain a high-quality, reliable and economically beneficial method suitable for routine application in practice. These tests were subsequently used for quantification of cow milk in commercial "Bryndza". Raw sheep milk, cow milk and heat-treated cow milk (pasteurisation at 72 °C for 15 sec or at 85 °C for 3 sec were mixed in precisely defined proportions (0 - 100% cow milk in sheep milk. The milk mixtures were sampled to detect adulteration and subsequently cheese was made. By ELISA tests was possible to determine these amounts of raw cow milk in sheep milk: 0.5% (0.2%, 5 % (4.81%, 50% (42.08% and 75% (56.52%. The pasteurized samples in different combinations gave lower optical density responses than those prepared from raw milk (by approximately 60%. In context with the above mentioned, the relationship between the real and detected amount of cow milk (% in different production stages (milk, cheese using a regression analysis was examined. However, a lower reliability of the detection was indicated by R2 values, which ranged from 0.4058 (cheese to 0.5175 (milk. In practice this means that although individual percentage (% of cow milk in the sample can be detected, but in the unknown sample it can not be clearly confirm whether the cow milk was raw or heat-treated. In this context, the results can be inaccurate and may not correspond to the real situation. Within monitoring phase of this research, 9 samples of bryndza were analysed with the results of detected cow milk ranged from 11.56% to 14.3%. The obtained results confirm that the appropriate selection of ELISA tests can become an important factor in the setting of analytical capabilities for the detection of milk and cheese adulteration.

  14. Enhanced Performance of Sandwich Structures by Improved Damage Tolerance

    DEFF Research Database (Denmark)

    Martakos, Georgios

    are embedded in both sandwich beam and panel specimens. The experimental observations form the basis for evaluating the efficiency of the proposed crack stopping inserts. For the experiments, Digital Image Correlation (DIC) was used to characterize the measure the local strain fields and overall deformation...... behaviour around the new crack stopper elements. In support for the experimental investigations, a Finite Element (FE) analysis based methodology, including fracture mechanics analysis and the so-called ‘cycle jump’ technique, was developed to predict the progression of damage in sandwich specimens...... concentrations in the foam core material on the back side of the peel stopper. By use of the developed numerical fracture mechanics based modelling tools, both fatigue crack growth and crack arrest in the specimens were simulated. It was shown that the strains responsible for crack re-initiation can...

  15. Performance of an ELISA and Indirect Immunofluorescence Assay in Serological Diagnosis of Zoonotic Cutaneous Leishmaniasis in Iran

    Directory of Open Access Journals (Sweden)

    Bahador Sarkari

    2014-01-01

    Full Text Available Serological assays have been extensively evaluated for diagnosis of visceral leishmaniasis (VL and considered as a routine method for diagnosis of VL while these methods are not properly evaluated for diagnosis of cutaneous leishmaniasis (CL. This study aimed to assess the performance of indirect immunofluorescent-antibody test (IFA and enzyme-linked immunosorbent assay (ELISA for serodiagnosis of cutaneous leishmaniasis in Iran. Sixty-one sera samples from parasitologically confirmed CL patients and 50 sera from healthy controls along with 50 sera from non-CL patients were collected. Antigen was prepared from promastigotes and amastigotes of Leishmania major. IFA was used to detect anti-Leishmania IgG while ELISA was used to detect anti-Leishmania IgM, total IgG, or IgG subclasses (IgG1 and 4. ELISA, for detection of total IgG and IgM, showed sensitivity of 83.6% and 84.7% and specificity of 62.7% and 54.6%, respectively. Sensitivity and specificity of ELISA for detecting IgG1 and IgG4 were 64%, 75% and 85%, 49%, respectively. Sensitivity and specificity of IFA were 91.6% and 81%. Conclusion. Findings of this study demonstrated that serological test, especially IFA, can be used for proper diagnosis of CL.

  16. Vibration Characteristics of Axially Moving Titanium- Polymer Nanocomposite Faced Sandwich Plate Under Initial Tension

    Directory of Open Access Journals (Sweden)

    Ali Ghorbanpour Arani

    2017-07-01

    Full Text Available In the present research, vibration and instability of axially moving sandwich plate made of soft core and composite face sheets under initial tension is investigated. Single-walled carbon nano-tubes (SWCNTs are selected as a reinforcement of composite face sheets inside Poly methyl methacrylate (PMMA matrix. Higher order shear deformation theory (HSDT is utilized due to its accuracy of polynomial functions than other plate theories. Based on extended rule of mixture, the structural properties of composite face sheets are taken into consideration. Motion equations are obtained by means of Hamilton’s principle and solved analytically. Influences of various parameters such as axially moving speed, volume fraction of CNTs, pre-tension, thickness and aspect ratio of sandwich plate on the vibration characteristics of moving system are discussed in details. The results indicated that the critical speed of moving sandwich plate is strongly dependent on the volume fraction of CNTs. Therefore, the critical speed of moving sandwich plate can be improved by adding appropriate values of CNTs. The results of this investigation can be used in design and manufacturing of marine vessels and aircrafts.

  17. Mechanical and vibro-acoustic aspects of composite sandwich cylinders

    NARCIS (Netherlands)

    Yuan, C.

    2013-01-01

    Designing a fuselage involves many considerations such as strength and stability, fatigue, damage tolerance, fire and lightning resistance, thermal and acoustic insulation, production, inspection, maintenance and repair. In the background of the application of composite sandwich structures on the

  18. Preparation of Ultrahigh Molecular Weight Polyethylene/Graphene Nanocomposite In situ Polymerization via Spherical and Sandwich Structure Graphene/Sio2 Support

    Science.gov (United States)

    Su, Enqi; Gao, Wensheng; Hu, Xinjun; Zhang, Caicai; Zhu, Bochao; Jia, Junji; Huang, Anping; Bai, Yongxiao

    2018-04-01

    Reduced graphene oxide/SiO2 (RGO/SiO2) serving as a novel spherical support for Ziegler-Natta (Z-N) catalyst is reported. The surface and interior of the support has a porous architecture formed by RGO/SiO2 sandwich structure. The sandwich structure is like a brick wall coated with a graphene layer of concreted as skeleton which could withstand external pressures and endow the structure with higher support stabilities. After loading the Z-N catalyst, the active components anchor on the surface and internal pores of the supports. When the ethylene molecules meet the active centers, the molecular chains grow from the surface and internal catalytic sites in a regular and well-organized way. And the process of the nascent molecular chains filled in the sandwich structure polymerization could ensure the graphene disperse uniformly in the polymer matrix. Compared with traditional methods, the porous spherical graphene support of this strategy has far more advantages and could maintain an intrinsic graphene performance in the nanocomposites.

  19. Hypervelocity Impact Performance of Open Cell Foam Core Sandwich Panel Structures

    Science.gov (United States)

    Ryan, S.; Ordonez, E.; Christiansen, E. L.; Lear, D. M.

    2010-01-01

    Open cell metallic foam core sandwich panel structures are of interest for application in spacecraft micrometeoroid and orbital debris shields due to their novel form and advantageous structural and thermal performance. Repeated shocking as a result of secondary impacts upon individual foam ligaments during the penetration process acts to raise the thermal state of impacting projectiles ; resulting in fragmentation, melting, and vaporization at lower velocities than with traditional shielding configurations (e.g. Whipple shield). In order to characterize the protective capability of these structures, an extensive experimental campaign was performed by the Johnson Space Center Hypervelocity Impact Technology Facility, the results of which are reported in this paper. Although not capable of competing against the protection levels achievable with leading heavy shields in use on modern high-risk vehicles (i.e. International Space Station modules), metallic foam core sandwich panels are shown to provide a substantial improvement over comparable structural panels and traditional low weight shielding alternatives such as honeycomb sandwich panels and metallic Whipple shields. A ballistic limit equation, generalized in terms of panel geometry, is derived and presented in a form suitable for application in risk assessment codes.

  20. Detection of IgE in the sera of rodents: comparison of the applicability of ELISA and RIA

    Energy Technology Data Exchange (ETDEWEB)

    Reiner, G; Zahner, H [Institut fuer Parasitologie der Justus-Liebig-Universitaet Giessen, Germany, F.R.; Haque, A [Institut Pasteur, 59 - Lille (France). Centre d' Immunologie et de Biologie Parasitaire

    1984-04-13

    RIA and ELISA were compared for their ability to detect IgE in different rodent species. With a sheep anti-rat IgE antibody good correlation (P < 0.001) between the 2 assay methods for IgE was found in rats. RIA failed to detect the IgE of Mastomys natalensis while ELISA proved to be a suitable test. However, both tests failed to measure IgE in sera of Nile rats.