WorldWideScience

Sample records for sampling units psus

  1. Regional soil erosion assessment based on a sample survey and geostatistics

    Science.gov (United States)

    Yin, Shuiqing; Zhu, Zhengyuan; Wang, Li; Liu, Baoyuan; Xie, Yun; Wang, Guannan; Li, Yishan

    2018-03-01

    Soil erosion is one of the most significant environmental problems in China. From 2010 to 2012, the fourth national census for soil erosion sampled 32 364 PSUs (Primary Sampling Units, small watersheds) with the areas of 0.2-3 km2. Land use and soil erosion controlling factors including rainfall erosivity, soil erodibility, slope length, slope steepness, biological practice, engineering practice, and tillage practice for the PSUs were surveyed, and the soil loss rate for each land use in the PSUs was estimated using an empirical model, the Chinese Soil Loss Equation (CSLE). Though the information collected from the sample units can be aggregated to estimate soil erosion conditions on a large scale; the problem of estimating soil erosion condition on a regional scale has not been addressed well. The aim of this study is to introduce a new model-based regional soil erosion assessment method combining a sample survey and geostatistics. We compared seven spatial interpolation models based on the bivariate penalized spline over triangulation (BPST) method to generate a regional soil erosion assessment from the PSUs. Shaanxi Province (3116 PSUs) in China was selected for the comparison and assessment as it is one of the areas with the most serious erosion problem. Ten-fold cross-validation based on the PSU data showed the model assisted by the land use, rainfall erosivity factor (R), soil erodibility factor (K), slope steepness factor (S), and slope length factor (L) derived from a 1 : 10 000 topography map is the best one, with the model efficiency coefficient (ME) being 0.75 and the MSE being 55.8 % of that for the model assisted by the land use alone. Among four erosion factors as the covariates, the S factor contributed the most information, followed by K and L factors, and R factor made almost no contribution to the spatial estimation of soil loss. The LS factor derived from 30 or 90 m Shuttle Radar Topography Mission (SRTM) digital elevation model (DEM) data

  2. Regional soil erosion assessment based on a sample survey and geostatistics

    Directory of Open Access Journals (Sweden)

    S. Yin

    2018-03-01

    Full Text Available Soil erosion is one of the most significant environmental problems in China. From 2010 to 2012, the fourth national census for soil erosion sampled 32 364 PSUs (Primary Sampling Units, small watersheds with the areas of 0.2–3 km2. Land use and soil erosion controlling factors including rainfall erosivity, soil erodibility, slope length, slope steepness, biological practice, engineering practice, and tillage practice for the PSUs were surveyed, and the soil loss rate for each land use in the PSUs was estimated using an empirical model, the Chinese Soil Loss Equation (CSLE. Though the information collected from the sample units can be aggregated to estimate soil erosion conditions on a large scale; the problem of estimating soil erosion condition on a regional scale has not been addressed well. The aim of this study is to introduce a new model-based regional soil erosion assessment method combining a sample survey and geostatistics. We compared seven spatial interpolation models based on the bivariate penalized spline over triangulation (BPST method to generate a regional soil erosion assessment from the PSUs. Shaanxi Province (3116 PSUs in China was selected for the comparison and assessment as it is one of the areas with the most serious erosion problem. Ten-fold cross-validation based on the PSU data showed the model assisted by the land use, rainfall erosivity factor (R, soil erodibility factor (K, slope steepness factor (S, and slope length factor (L derived from a 1 : 10 000 topography map is the best one, with the model efficiency coefficient (ME being 0.75 and the MSE being 55.8 % of that for the model assisted by the land use alone. Among four erosion factors as the covariates, the S factor contributed the most information, followed by K and L factors, and R factor made almost no contribution to the spatial estimation of soil loss. The LS factor derived from 30 or 90 m Shuttle Radar Topography Mission

  3. An Integrated Start-Up Method for Pumped Storage Units Based on a Novel Artificial Sheep Algorithm

    Directory of Open Access Journals (Sweden)

    Zanbin Wang

    2018-01-01

    Full Text Available Pumped storage units (PSUs are an important storage tool for power systems containing large-scale renewable energy, and the merit of rapid start-up enable PSUs to modulate and stabilize the power system. In this paper, PSU start-up strategies have been studied and a new integrated start-up method has been proposed for the purpose of achieving swift and smooth start-up. A two-phase closed-loop startup strategy, composed of switching Proportion Integration (PI and Proportion Integration Differentiation (PID controller is designed, and an integrated optimization scheme is proposed for a synchronous optimization of the parameters in the strategy. To enhance the optimization performance, a novel meta-heuristic called Artificial Sheep Algorithm (ASA is proposed and applied to solve the optimization task after a sufficient verification with seven popular meta-heuristic algorithms and 13 typical benchmark functions. Simulation model has been built for a China’s PSU and comparative experiments are conducted to evaluate the proposed integrated method. Results show that the start-up performance could be significantly improved on both indices on overshoot and start-up, and up to 34%-time consumption has been reduced under different working condition. The significant improvements on start-up of PSU is interesting and meaning for further application on real unit.

  4. Methodology for Evaluating the Quality of Ecosystem Maps: A Case Study in the Andes

    Directory of Open Access Journals (Sweden)

    Dolors Armenteras

    2016-08-01

    Full Text Available Uncertainty in thematic maps has been tested mainly in maps with discrete or fuzzy classifications based on spectral data. However, many ecosystem maps in tropical countries consist of discrete polygons containing information on various ecosystem properties such as vegetation cover, soil, climate, geomorphology and biodiversity. The combination of these properties into one class leads to error. We propose a probability-based sampling design with two domains, multiple stages, and stratification with selection of primary sampling units (PSUs proportional to the richness of strata present. Validation is undertaken through field visits and fine resolution remote sensing data. A pilot site in the center of the Colombian Andes was chosen to validate a government official ecosystem map. Twenty primary sampling units (PSUs of 10 × 15 km were selected, and the final numbers of final sampling units (FSUs were 76 for the terrestrial domain and 46 for the aquatic domain. Our results showed a confidence level of 95%, with the accuracy in the terrestrial domain varying between 51.8% and 64.3% and in the aquatic domain varying between 75% and 92%. Governments need to account for uncertainty since they rely on the quality of these maps to make decisions and guide policies.

  5. Synthetic Multiple-Imputation Procedure for Multistage Complex Samples

    Directory of Open Access Journals (Sweden)

    Zhou Hanzhi

    2016-03-01

    Full Text Available Multiple imputation (MI is commonly used when item-level missing data are present. However, MI requires that survey design information be built into the imputation models. For multistage stratified clustered designs, this requires dummy variables to represent strata as well as primary sampling units (PSUs nested within each stratum in the imputation model. Such a modeling strategy is not only operationally burdensome but also inferentially inefficient when there are many strata in the sample design. Complexity only increases when sampling weights need to be modeled. This article develops a generalpurpose analytic strategy for population inference from complex sample designs with item-level missingness. In a simulation study, the proposed procedures demonstrate efficient estimation and good coverage properties. We also consider an application to accommodate missing body mass index (BMI data in the analysis of BMI percentiles using National Health and Nutrition Examination Survey (NHANES III data. We argue that the proposed methods offer an easy-to-implement solution to problems that are not well-handled by current MI techniques. Note that, while the proposed method borrows from the MI framework to develop its inferential methods, it is not designed as an alternative strategy to release multiply imputed datasets for complex sample design data, but rather as an analytic strategy in and of itself.

  6. Unit 06 - Sampling the World

    OpenAIRE

    Unit 06, CC in GIS; Parson, Charles; Nyerges, Timothy

    1990-01-01

    This unit begins the section on data acquisition by looking at how the infinite complexity of the real world can be discretized and sampled. It considers sampling techniques and associated issues of accuracy and standards.

  7. 21 CFR 203.38 - Sample lot or control numbers; labeling of sample units.

    Science.gov (United States)

    2010-04-01

    ... numbers; labeling of sample units. (a) Lot or control number required on drug sample labeling and sample... identifying lot or control number that will permit the tracking of the distribution of each drug sample unit... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Sample lot or control numbers; labeling of sample...

  8. Safety analysis report for the mixed waste storage facility and portable storage units at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Peatross, R.

    1997-01-01

    The Mixed Waste Storage Facility (MWSF) including the Portable Storage Units (PSUs) is a government-owned contractor-operated facility located at the Idaho National Engineering Laboratory (INEL). Lockheed Martin Idaho Technologies Company (LMITCO) is the current operating contractor and facility Architect/Engineer as of September 1996. The operating contractor is referred to as open-quotes the Companyclose quotes or open-quotes Companyclose quotes throughout this document. Oversight of MWSF is provided by the Department of Energy Idaho Operations Office (DOE-ID). The MWSF is located in the Power Burst Facility (PBF) Waste Reduction Operations Complex (WROC) Area, approximately 10.6 km (6.6 mi) from the southern INEL boundary and 4 km (2.5 mi) from U.S. Highway 20

  9. 30 CFR 70.207 - Bimonthly sampling; mechanized mining units.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bimonthly sampling; mechanized mining units. 70... MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures § 70.207 Bimonthly sampling; mechanized mining units. (a) Each operator shall take five valid respirable dust samples...

  10. Portable field water sample filtration unit

    International Nuclear Information System (INIS)

    Hebert, A.J.; Young, G.G.

    1977-01-01

    A lightweight back-packable field-tested filtration unit is described. The unit is easily cleaned without cross contamination at the part-per-billion level and allows rapid filtration of boiling hot and sometimes muddy water. The filtration results in samples that are free of bacteria and particulates and which resist algae growth even after storage for months. 3 figures

  11. Redesign of a health science centre: reflections on co-leadership.

    Science.gov (United States)

    MacTavish, M; Norton, P

    1995-01-01

    Since 1988, the Sunnybrook Health Science Centre has been proactive in re-designing its system toward decentralized management, the purpose being to further enhance patient care. This process has involved numerous changes, among which were the establishment of three large clinical units. These clinical units are not defined following the historic medical model, but group patients with similar service and care needs. Subsequently, each of the clinical units defined Patient Service Units (PSUs). The hospital has chosen a co-leadership model for the lead management at each of the unit levels. This paper describes the model for clinical units.

  12. Pacific Northwest National Laboratory Facility Radionuclide Emissions Units and Sampling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, J. Matthew; Brown, Jason H.; Walker, Brian A.

    2012-04-01

    Battelle–Pacific Northwest Division operates numerous research and development (R&D) laboratories in Richland, WA, including those associated with Pacific Northwest National Laboratory (PNNL) on the U.S. Department of Energy (DOE)’s Hanford Site and PNNL Site that have the potential for radionuclide air emissions. The National Emission Standard for Hazardous Air Pollutants (NESHAP 40 CFR 61, Subparts H and I) requires an assessment of all emission units that have the potential for radionuclide air emissions. Potential emissions are assessed annually by PNNL staff members. Sampling, monitoring, and other regulatory compliance requirements are designated based upon the potential-to-emit dose criteria found in the regulations. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission unit system performance, operation, and design information. For sampled systems, a description of the buildings, exhaust units, control technologies, and sample extraction details is provided for each registered emission unit. Additionally, applicable stack sampler configuration drawings, figures, and photographs are provided. Deregistered emission unit details are provided as necessary for up to 5 years post closure.

  13. Analysis of Product Sampling for New Product Diffusion Incorporating Multiple-Unit Ownership

    Directory of Open Access Journals (Sweden)

    Zhineng Hu

    2014-01-01

    Full Text Available Multiple-unit ownership of nondurable products is an important component of sales in many product categories. Based on the Bass model, this paper develops a new model considering the multiple-unit adoptions as a diffusion process under the influence of product sampling. Though the analysis aims to determine the optimal dynamic sampling effort for a firm and the results demonstrate that experience sampling can accelerate the diffusion process, the best time to send free samples is just before the product being launched. Multiple-unit purchasing behavior can increase sales to make more profit for a firm, and it needs more samples to make the product known much better. The local sensitivity analysis shows that the increase of both external coefficients and internal coefficients has a negative influence on the sampling level, but the internal influence on the subsequent multiple-unit adoptions has little significant influence on the sampling. Using the logistic regression along with linear regression, the global sensitivity analysis gives a whole analysis of the interaction of all factors, which manifests the external influence and multiunit purchase rate are two most important factors to influence the sampling level and net present value of the new product, and presents a two-stage method to determine the sampling level.

  14. Accounting for Diversity in Suicide Research: Sampling and Sample Reporting Practices in the United States.

    Science.gov (United States)

    Cha, Christine B; Tezanos, Katherine M; Peros, Olivia M; Ng, Mei Yi; Ribeiro, Jessica D; Nock, Matthew K; Franklin, Joseph C

    2018-04-01

    Research on suicidal thoughts and behaviors (STB) has identified many risk factors, but whether these findings generalize to diverse populations remains unclear. We review longitudinal studies on STB risk factors over the past 50 years in the United States and evaluate the methodological practices of sampling and reporting sample characteristics. We found that articles frequently reported participant age and sex, less frequently reported participant race and ethnicity, and rarely reported participant veteran status or lesbian, gay, bisexual, and transgender status. Sample reporting practices modestly and inconsistently improved over time. Finally, articles predominantly featured White, non-Hispanic, young adult samples. © 2017 The American Association of Suicidology.

  15. Definition of sampling units begets conclusions in ecology: the case of habitats for plant communities

    OpenAIRE

    M?rsdorf, Martin A.; Ravolainen, Virve T.; St?vern, Leif Einar; Yoccoz, Nigel G.; J?nsd?ttir, Ingibj?rg Svala; Br?then, Kari Anne

    2015-01-01

    In ecology, expert knowledge on habitat characteristics is often used to define sampling units such as study sites. Ecologists are especially prone to such approaches when prior sampling frames are not accessible. Here we ask to what extent can different approaches to the definition of sampling units influence the conclusions that are drawn from an ecological study? We do this by comparing a formal versus a subjective definition of sampling units within a study design which is ...

  16. Recombinative generalization of subword units using matching to sample.

    LENUS (Irish Health Repository)

    Mahon, Catherine

    2010-01-01

    The purpose of the current study was to develop and test a computerized matching-to-sample (MTS) protocol to facilitate recombinative generalization of subword units (onsets and rimes) and recognition of novel onset-rime and onset-rime-rime words. In addition, we sought to isolate the key training components necessary for recombinative generalization. Twenty-five literate adults participated. Conditional discrimination training emerged as a crucial training component. These findings support the effectiveness of MTS in facilitating recombinative generalization, particularly when conditional discrimination training with subword units is used.

  17. Operable Unit 3-13, Group 3, Other Surface Soils (Phase II) Field Sampling Plan

    Energy Technology Data Exchange (ETDEWEB)

    G. L. Schwendiman

    2006-07-27

    This Field Sampling Plan describes the Operable Unit 3-13, Group 3, Other Surface Soils, Phase II remediation field sampling activities to be performed at the Idaho Nuclear Technology and Engineering Center located within the Idaho National Laboratory Site. Sampling activities described in this plan support characterization sampling of new sites, real-time soil spectroscopy during excavation, and confirmation sampling that verifies that the remedial action objectives and remediation goals presented in the Final Record of Decision for Idaho Nuclear Technology and Engineering Center, Operable Unit 3-13 have been met.

  18. Definition of sampling units begets conclusions in ecology: the case of habitats for plant communities

    Directory of Open Access Journals (Sweden)

    Martin A. Mörsdorf

    2015-03-01

    Full Text Available In ecology, expert knowledge on habitat characteristics is often used to define sampling units such as study sites. Ecologists are especially prone to such approaches when prior sampling frames are not accessible. Here we ask to what extent can different approaches to the definition of sampling units influence the conclusions that are drawn from an ecological study? We do this by comparing a formal versus a subjective definition of sampling units within a study design which is based on well-articulated objectives and proper methodology. Both approaches are applied to tundra plant communities in mesic and snowbed habitats. For the formal approach, sampling units were first defined for each habitat in concave terrain of suitable slope using GIS. In the field, these units were only accepted as the targeted habitats if additional criteria for vegetation cover were fulfilled. For the subjective approach, sampling units were defined visually in the field, based on typical plant communities of mesic and snowbed habitats. For each approach, we collected information about plant community characteristics within a total of 11 mesic and seven snowbed units distributed between two herding districts of contrasting reindeer density. Results from the two approaches differed significantly in several plant community characteristics in both mesic and snowbed habitats. Furthermore, differences between the two approaches were not consistent because their magnitude and direction differed both between the two habitats and the two reindeer herding districts. Consequently, we could draw different conclusions on how plant diversity and relative abundance of functional groups are differentiated between the two habitats depending on the approach used. We therefore challenge ecologists to formalize the expert knowledge applied to define sampling units through a set of well-articulated rules, rather than applying it subjectively. We see this as instrumental for progress in

  19. Definition of sampling units begets conclusions in ecology: the case of habitats for plant communities.

    Science.gov (United States)

    Mörsdorf, Martin A; Ravolainen, Virve T; Støvern, Leif Einar; Yoccoz, Nigel G; Jónsdóttir, Ingibjörg Svala; Bråthen, Kari Anne

    2015-01-01

    In ecology, expert knowledge on habitat characteristics is often used to define sampling units such as study sites. Ecologists are especially prone to such approaches when prior sampling frames are not accessible. Here we ask to what extent can different approaches to the definition of sampling units influence the conclusions that are drawn from an ecological study? We do this by comparing a formal versus a subjective definition of sampling units within a study design which is based on well-articulated objectives and proper methodology. Both approaches are applied to tundra plant communities in mesic and snowbed habitats. For the formal approach, sampling units were first defined for each habitat in concave terrain of suitable slope using GIS. In the field, these units were only accepted as the targeted habitats if additional criteria for vegetation cover were fulfilled. For the subjective approach, sampling units were defined visually in the field, based on typical plant communities of mesic and snowbed habitats. For each approach, we collected information about plant community characteristics within a total of 11 mesic and seven snowbed units distributed between two herding districts of contrasting reindeer density. Results from the two approaches differed significantly in several plant community characteristics in both mesic and snowbed habitats. Furthermore, differences between the two approaches were not consistent because their magnitude and direction differed both between the two habitats and the two reindeer herding districts. Consequently, we could draw different conclusions on how plant diversity and relative abundance of functional groups are differentiated between the two habitats depending on the approach used. We therefore challenge ecologists to formalize the expert knowledge applied to define sampling units through a set of well-articulated rules, rather than applying it subjectively. We see this as instrumental for progress in ecology as only rules

  20. Sampling and Control Circuit Board for an Inertial Measurement Unit

    Science.gov (United States)

    Chelmins, David T (Inventor); Powis, Richard T., Jr. (Inventor); Sands, Obed (Inventor)

    2016-01-01

    A circuit board that serves as a control and sampling interface to an inertial measurement unit ("IMU") is provided. The circuit board is also configured to interface with a local oscillator and an external trigger pulse. The circuit board is further configured to receive the external trigger pulse from an external source that time aligns the local oscillator and initiates sampling of the inertial measurement device for data at precise time intervals based on pulses from the local oscillator. The sampled data may be synchronized by the circuit board with other sensors of a navigation system via the trigger pulse.

  1. STUDY OF HOME DEMONSTRATION UNITS IN A SAMPLE OF 27 COUNTIES IN NEW YORK STATE, NUMBER 3.

    Science.gov (United States)

    ALEXANDER, FRANK D.; HARSHAW, JEAN

    AN EXPLORATORY STUDY EXAMINED CHARACTERISTICS OF 1,128 HOME DEMONSTRATION UNITS TO SUGGEST HYPOTHESES AND SCOPE FOR A MORE INTENSIVE STUDY OF A SMALL SAMPLE OF UNITS, AND TO PROVIDE GUIDANCE IN SAMPLING. DATA WERE OBTAINED FROM A SPECIALLY DESIGNED MEMBERSHIP CARD USED IN 1962. UNIT SIZE AVERAGED 23.6 MEMBERS BUT THE RANGE WAS FAIRLY GREAT. A NEED…

  2. Data validation report for the 100-HR-3 Operable Unit, fifth round groundwater samples

    International Nuclear Information System (INIS)

    Vukelich, S.E.

    1994-01-01

    The data from the chemical analysis of 68 samples from the 100-HR-3 Operable Unit Third Quarter 1993 Groundwater Sampling Investigation and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at the site. Sample analysis included inorganics and general chemical parameters. Fifty three samples were validated for radiochemical parameters

  3. Data validation report for the 100-D Ponds Operable Unit: 100-D ponds sampling

    International Nuclear Information System (INIS)

    Stankovich, M.T.

    1994-01-01

    Westinghouse-Hanford has requested that 100 percent of the Sample Delivery Groups be validated for the 100-D Ponds Operable Unit Sampling Investigation. Therefore the data from the chemical analysis of all 30 samples from this sampling event and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site

  4. Heel blood sampling in European neonatal intensive care units: compliance with pain management guidelines

    DEFF Research Database (Denmark)

    Losacco, Valentina; Cuttini, Marina; Greisen, Gorm

    2011-01-01

    Objective To describe the use of heel blood sampling and non-pharmacological analgesia in a large representative sample of neonatal intensive care units (NICUs) in eight European countries, and compare their self-reported practices with evidence-based recommendations. Methods Information on use...... of heel blood sampling and associated procedures (oral sweet solutions, non-nutritive sucking, swaddling or positioning, topical anaesthetics and heel warming) were collected through a structured mail questionnaire. 284 NICUs (78% response rate) participated, but only 175 with >/=50 very low birth weight...... admissions per year were included in this analysis. Results Use of heel blood sampling appeared widespread. Most units in the Netherlands, UK, Denmark, Sweden and France predominantly adopted mechanical devices, while manual lance was still in use in the other countries. The two Scandinavian countries...

  5. Study on Quantification for Multi-unit Seismic PSA Model using Monte Carlo Sampling

    International Nuclear Information System (INIS)

    Oh, Kyemin; Han, Sang Hoon; Jang, Seung-cheol; Park, Jin Hee; Lim, Ho-Gon; Yang, Joon Eon; Heo, Gyunyoung

    2015-01-01

    In existing PSA, frequency for accident sequences occurred in single-unit has been estimated. While multi-unit PSA has to consider various combinations because accident sequence in each units can be different. However, it is difficult to quantify all of combination between inter-units using traditional method such as Minimal Cut Upper Bound (MCUB). For this reason, we used Monte Carlo sampling as a method to quantify multi-unit PSA model. In this paper, Monte Carlo method was used to quantify multi-unit PSA model. The advantage of this method is to consider all of combinations by the increase of number of unit and to calculate nearly exact value compared to other method. However, it is difficult to get detailed information such as minimal cut sets and accident sequence. To solve partially this problem, FTeMC was modified. In multi-unit PSA, quantification for both internal and external multi-unit accidents is the significant issue. Although our result above mentioned was one of the case studies to check application of method suggested in this paper, it is expected that this method can be used in practical assessment for multi-unit risk

  6. Data validation summary report for the 100-BC-5 Operable Unit Round 8 Groundwater Sampling

    International Nuclear Information System (INIS)

    Kearney, A.T.

    1996-03-01

    The information provided in this validation summary report includes data from the chemical analyses of samples from the 100-BC-5 Operable Unit Round 8 Groundwater Sampling Investigation. All of the data from this sampling event and their related quality assurance samples were reviewed and validated to verify that the reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site. Sample analyses included metals, general chemistry and radiochemistry

  7. A United States forensic sample for the Gudjonsson Suggestibility Scales.

    Science.gov (United States)

    Frumkin, I Bruce; Lally, Stephen J; Sexton, James E

    2012-01-01

    The Gudjonsson Suggestibility Scales (GSS) is a valuable test to use as part of a comprehensive assessment of psychological and interrogative factors relevant to a defendant's vulnerability to giving a false or involuntary confession. One limitation of the test is that the manual only provides information for samples from Iceland and Great Britain. This report describes the results of 334 individuals in the United States, who were administered the tests as part of an evaluation to assess confession-related issues in a forensic context (i.e., capacity to waive Miranda rights or vulnerability in providing a false or involuntary confession). This forensic sample includes both juveniles and adults. Results are consistent with Gudjonsson's British and Icelandic samples, in which the Yield 1 score is more affected by intellectual and cognitive variables, but Shift and, to a lesser extent, Yield 2 scores are more related to emotional and personality characteristics. Copyright © 2012 John Wiley & Sons, Ltd.

  8. Unit Stratified Sampling as a Tool for Approximation of Stochastic Optimization Problems

    Czech Academy of Sciences Publication Activity Database

    Šmíd, Martin

    2012-01-01

    Roč. 19, č. 30 (2012), s. 153-169 ISSN 1212-074X R&D Projects: GA ČR GAP402/11/0150; GA ČR GAP402/10/0956; GA ČR GA402/09/0965 Institutional research plan: CEZ:AV0Z10750506 Institutional support: RVO:67985556 Keywords : Stochastic programming * approximation * stratified sampling Subject RIV: BB - Applied Statistics, Operational Research http://library.utia.cas.cz/separaty/2013/E/smid-unit stratified sampling as a tool for approximation of stochastic optimization problems.pdf

  9. Sampling and decontamination plan for the Transuranic Storage Area--1/-R container storage unit

    International Nuclear Information System (INIS)

    Barry, G.A.

    1992-11-01

    This document describes the sampling and decontamination of the Transuranic Storage Area (TSA)-l/-R container storage area and the earthen-covered portion of the TSA-2 container storage unit at the Radioactive Waste Management Complex. Stored containers from the earthen-covered asphalt pads will be retrieved from the TSA-l/-R and TSA-2 container storage units. Container retrieval will be conducted under the TSA retrieval enclosure, a fabricated steel building to be constructed over the earthen-covered pad to provide containment and weather protection. Following container retrieval, the TSA retrieval enclosure will be decontaminated to remove radioactive and hazardous contamination. The underlying soils will be sampled and analyzed to determine whether any contaminated soils require removal

  10. Automated Blood Sample Preparation Unit (ABSPU) for Portable Microfluidic Flow Cytometry.

    Science.gov (United States)

    Chaturvedi, Akhil; Gorthi, Sai Siva

    2017-02-01

    Portable microfluidic diagnostic devices, including flow cytometers, are being developed for point-of-care settings, especially in conjunction with inexpensive imaging devices such as mobile phone cameras. However, two pervasive drawbacks of these have been the lack of automated sample preparation processes and cells settling out of sample suspensions, leading to inaccurate results. We report an automated blood sample preparation unit (ABSPU) to prevent blood samples from settling in a reservoir during loading of samples in flow cytometers. This apparatus automates the preanalytical steps of dilution and staining of blood cells prior to microfluidic loading. It employs an assembly with a miniature vibration motor to drive turbulence in a sample reservoir. To validate performance of this system, we present experimental evidence demonstrating prevention of blood cell settling, cell integrity, and staining of cells prior to flow cytometric analysis. This setup is further integrated with a microfluidic imaging flow cytometer to investigate cell count variability. With no need for prior sample preparation, a drop of whole blood can be directly introduced to the setup without premixing with buffers manually. Our results show that integration of this assembly with microfluidic analysis provides a competent automation tool for low-cost point-of-care blood-based diagnostics.

  11. Problematic smartphone use, nature connectedness, and anxiety.

    Science.gov (United States)

    Richardson, Miles; Hussain, Zaheer; Griffiths, Mark D

    2018-03-01

    Background Smartphone use has increased greatly at a time when concerns about society's disconnection from nature have also markedly increased. Recent research has also indicated that smartphone use can be problematic for a small minority of individuals. Methods In this study, associations between problematic smartphone use (PSU), nature connectedness, and anxiety were investigated using a cross-sectional design (n = 244). Results Associations between PSU and both nature connectedness and anxiety were confirmed. Receiver operating characteristic (ROC) curves were used to identify threshold values on the Problematic Smartphone Use Scale (PSUS) at which strong associations with anxiety and nature connectedness occur. The area under the curve was calculated and positive likelihood ratios used as a diagnostic parameter to identify optimal cut-off for PSU. These provided good diagnostic ability for nature connectedness, but poor and non-significant results for anxiety. ROC analysis showed the optimal PSUS threshold for high nature connectedness to be 15.5 (sensitivity: 58.3%; specificity: 78.6%) in response to an LR+ of 2.88. Conclusions The results demonstrate the potential utility for the PSUS as a diagnostic tool, with a level of smartphone use that users may perceive as non-problematic being a significant cut-off in terms of achieving beneficial levels of nature connectedness. Implications of these findings are discussed.

  12. Phase-Contrast Hounsfield Units of Fixated and Non-Fixated Soft-Tissue Samples

    Science.gov (United States)

    Willner, Marian; Fior, Gabriel; Marschner, Mathias; Birnbacher, Lorenz; Schock, Jonathan; Braun, Christian; Fingerle, Alexander A.; Noël, Peter B.; Rummeny, Ernst J.; Pfeiffer, Franz; Herzen, Julia

    2015-01-01

    X-ray phase-contrast imaging is a novel technology that achieves high soft-tissue contrast. Although its clinical impact is still under investigation, the technique may potentially improve clinical diagnostics. In conventional attenuation-based X-ray computed tomography, radiological diagnostics are quantified by Hounsfield units. Corresponding Hounsfield units for phase-contrast imaging have been recently introduced, enabling a setup-independent comparison and standardized interpretation of imaging results. Thus far, the experimental values of few tissue types have been reported; these values have been determined from fixated tissue samples. This study presents phase-contrast Hounsfield units for various types of non-fixated human soft tissues. A large variety of tissue specimens ranging from adipose, muscle and connective tissues to liver, kidney and pancreas tissues were imaged by a grating interferometer with a rotating-anode X-ray tube and a photon-counting detector. Furthermore, we investigated the effects of formalin fixation on the quantitative phase-contrast imaging results. PMID:26322638

  13. Sampling design and procedures for fixed surface-water sites in the Georgia-Florida coastal plain study unit, 1993

    Science.gov (United States)

    Hatzell, H.H.; Oaksford, E.T.; Asbury, C.E.

    1995-01-01

    The implementation of design guidelines for the National Water-Quality Assessment (NAWQA) Program has resulted in the development of new sampling procedures and the modification of existing procedures commonly used in the Water Resources Division of the U.S. Geological Survey. The Georgia-Florida Coastal Plain (GAFL) study unit began the intensive data collection phase of the program in October 1992. This report documents the implementation of the NAWQA guidelines by describing the sampling design and procedures for collecting surface-water samples in the GAFL study unit in 1993. This documentation is provided for agencies that use water-quality data and for future study units that will be entering the intensive phase of data collection. The sampling design is intended to account for large- and small-scale spatial variations, and temporal variations in water quality for the study area. Nine fixed sites were selected in drainage basins of different sizes and different land-use characteristics located in different land-resource provinces. Each of the nine fixed sites was sampled regularly for a combination of six constituent groups composed of physical and chemical constituents: field measurements, major ions and metals, nutrients, organic carbon, pesticides, and suspended sediments. Some sites were also sampled during high-flow conditions and storm events. Discussion of the sampling procedure is divided into three phases: sample collection, sample splitting, and sample processing. A cone splitter was used to split water samples for the analysis of the sampling constituent groups except organic carbon from approximately nine liters of stream water collected at four fixed sites that were sampled intensively. An example of the sample splitting schemes designed to provide the sample volumes required for each sample constituent group is described in detail. Information about onsite sample processing has been organized into a flowchart that describes a pathway for each of

  14. Groundwater-quality data in 12 GAMA study units: Results from the 2006–10 initial sampling period and the 2008–13 trend sampling period, California GAMA Priority Basin Project

    Science.gov (United States)

    Mathany, Timothy M.

    2017-03-09

    The Priority Basin Project (PBP) of the Groundwater Ambient Monitoring and Assessment (GAMA) program was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey in cooperation with the California State Water Resources Control Board. From 2004 through 2012, the GAMA-PBP collected samples and assessed the quality of groundwater resources that supply public drinking water in 35 study units across the State. Selected sites in each study unit were sampled again approximately 3 years after initial sampling as part of an assessment of temporal trends in water quality by the GAMA-PBP. Twelve of the study units, initially sampled during 2006–11 (initial sampling period) and sampled a second time during 2008–13 (trend sampling period) to assess temporal trends, are the subject of this report.The initial sampling was designed to provide a spatially unbiased assessment of the quality of untreated groundwater used for public water supplies in the 12 study units. In these study units, 550 sampling sites were selected by using a spatially distributed, randomized, grid-based method to provide spatially unbiased representation of the areas assessed (grid sites, also called “status sites”). After the initial sampling period, 76 of the previously sampled status sites (approximately 10 percent in each study unit) were randomly selected for trend sampling (“trend sites”). The 12 study units sampled both during the initial sampling and during the trend sampling period were distributed among 6 hydrogeologic provinces: Coastal (Northern and Southern), Transverse Ranges and Selected Peninsular Ranges, Klamath, Modoc Plateau and Cascades, and Sierra Nevada Hydrogeologic Provinces. For the purposes of this trend report, the six hydrogeologic provinces were grouped into two hydrogeologic regions based on location: Coastal and Mountain.The groundwater samples were analyzed for a number of synthetic organic

  15. Mendelian breeding units versus standard sampling strategies: mitochondrial DNA variation in southwest Sardinia

    Directory of Open Access Journals (Sweden)

    Daria Sanna

    2011-01-01

    Full Text Available We report a sampling strategy based on Mendelian Breeding Units (MBUs, representing an interbreeding group of individuals sharing a common gene pool. The identification of MBUs is crucial for case-control experimental design in association studies. The aim of this work was to evaluate the possible existence of bias in terms of genetic variability and haplogroup frequencies in the MBU sample, due to severe sample selection. In order to reach this goal, the MBU sampling strategy was compared to a standard selection of individuals according to their surname and place of birth. We analysed mitochondrial DNA variation (first hypervariable segment and coding region in unrelated healthy subjects from two different areas of Sardinia: the area around the town of Cabras and the western Campidano area. No statistically significant differences were observed when the two sampling methods were compared, indicating that the stringent sample selection needed to establish a MBU does not alter original genetic variability and haplogroup distribution. Therefore, the MBU sampling strategy can be considered a useful tool in association studies of complex traits.

  16. Avalik arvamus ja X Riigikogu meediauuringutes / Juhan Kivirähk

    Index Scriptorium Estoniae

    Kivirähk, Juhan, 1957-

    2004-01-01

    OÜ Uuringukeskus Faktum juhatuse esimehe sõnul on praegune, X Riigikogu pälvinud oma tegevuse algusest peale seniolematut suurt valijaskonna usaldust, mille põhjuseks on ilmselt avaliku arvamuse suurem küpsus. Diagrammid. Graafikud. Tabelid

  17. Data validation report for the 100-HR-3 Operable Unit first quarter 1994 groundwater sampling data

    Energy Technology Data Exchange (ETDEWEB)

    Biggerstaff, R.L.

    1994-06-24

    Westinghouse-Hanford has requested that a minimum of 20% of the total number of Sample Delivery Groups be validated for the 100-HR-3 Operable Unit First Quarter 1994 Groundwater Sampling Investigation. Therefore, the data from the chemical analysis of twenty-four samples from this sampling event and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site. The samples were analyzed by Thermo-Analytic Laboratories (TMA) and Roy F. Weston Laboratories (WESTON) using US Environmental Protection Agency (EPA) CLP protocols. Sample analyses included: inorganics; and general chemical parameters. Forty-two samples were validated for radiochemical parameters by TMA and Teledyne.

  18. Data validation report for the 100-HR-3 Operable Unit first quarter 1994 groundwater sampling data

    International Nuclear Information System (INIS)

    Biggerstaff, R.L.

    1994-01-01

    Westinghouse-Hanford has requested that a minimum of 20% of the total number of Sample Delivery Groups be validated for the 100-HR-3 Operable Unit First Quarter 1994 Groundwater Sampling Investigation. Therefore, the data from the chemical analysis of twenty-four samples from this sampling event and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site. The samples were analyzed by Thermo-Analytic Laboratories (TMA) and Roy F. Weston Laboratories (WESTON) using US Environmental Protection Agency (EPA) CLP protocols. Sample analyses included: inorganics; and general chemical parameters. Forty-two samples were validated for radiochemical parameters by TMA and Teledyne

  19. Data validation report for the 100-FR-3 Operable Unit, third round groundwater samples

    International Nuclear Information System (INIS)

    Ayres, J.M.

    1994-01-01

    Westinghouse-Hanford has requested that a minimum of 20% of the total number of Sample Delivery Groups be validated for the 100-FR-3 operable Unit Third Round Groundwater sampling investigation. Therefore, the data from the chemical analysis of 51 samples from this sampling event and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site. The report is broken down into sections for each chemical analysis and radiochemical analysis type. Each section addresses the data package completeness, holding time adherence, instrument calibration and tuning acceptability, blank results, accuracy, precision, system performance, as well as the compound identification and quantitation. In addition, each section has an overall assessment and summary for the data packages reviewed for the particular chemical/radiochemical analyses. Detailed backup information is provided to the reader by SDG No. and sample number. For each data package, a matrix of chemical analyses per sample number is presented, as well as data qualification summaries

  20. SAMPLING IN EXTERNAL AUDIT - THE MONETARY UNIT SAMPLING METHOD

    Directory of Open Access Journals (Sweden)

    E. Dascalu

    2016-12-01

    Full Text Available This article approaches the general issue of diminishing the evidence investigation space in audit activities, by means of sampling techniques, given that in the instance of a significant data volume an exhaustive examination of the assessed popula¬tion is not possible and/or effective. The general perspective of the presentation involves dealing with sampling risk, in essence, the risk that a selected sample may not be representative for the overall population, in correlation with the audit risk model and with the component parts of this model (inherent risk, control risk and non detection risk and highlights the inter-conditionings between these two models.

  1. Statistical Power and Optimum Sample Allocation Ratio for Treatment and Control Having Unequal Costs Per Unit of Randomization

    Science.gov (United States)

    Liu, Xiaofeng

    2003-01-01

    This article considers optimal sample allocation between the treatment and control condition in multilevel designs when the costs per sampling unit vary due to treatment assignment. Optimal unequal allocation may reduce the cost from that of a balanced design without sacrificing any power. The optimum sample allocation ratio depends only on the…

  2. Sampling and analysis plan for remediation of Operable Unit 100-IU-3 waste site 600-104

    International Nuclear Information System (INIS)

    1997-08-01

    This sampling and analysis plan (SAP) presents the rationale and strategy for the sampling and analysis activities to support remediation of 100-IU-3 Operable Unit waste site 600-104. The purpose of the proposed sampling and analysis activities is to demonstrate that time-critical remediation of the waste site for soil containing 2,4-Dichlorophonoxyacetic acid salts and esters (2,4-D) and dioxin/furan isomers at concentrations that exceed cleanup levels has been effective. This shall be accomplished by sampling various locations of the waste site before and after remediation, analyzing the samples, and comparing the results to action levels set by the Washington State Department of Ecology

  3. Nuclear thermal source transfer unit, post-blast soil sample drying system

    Energy Technology Data Exchange (ETDEWEB)

    Wiser, Ralph S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Valencia, Matthew J [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-03

    Los Alamos National Laboratory states that its mission is “To solve national security challenges through scientific excellence.” The Science Undergraduate Laboratory Internship (SULI) programs exists to engage undergraduate students in STEM work by providing opportunity to work at DOE facilities. As an undergraduate mechanical engineering intern under the SULI program at Los Alamos during the fall semester of 2016, I had the opportunity to contribute to the mission of the Laboratory while developing skills in a STEM discipline. I worked with Technology Applications, an engineering group that supports non-proliferation, counter terrorism, and emergency response missions. This group specializes in tool design, weapons engineering, rapid prototyping, and mission training. I assisted with two major projects during my appointment Los Alamos. The first was a thermal source transportation unit, intended to safely contain a nuclear thermal source during transit. The second was a soil drying unit for use in nuclear postblast field sample collection. These projects have given me invaluable experience working alongside a team of professional engineers. Skills developed include modeling, simulation, group design, product and system design, and product testing.

  4. Nuclear thermal source transfer unit, post-blast soil sample drying system

    International Nuclear Information System (INIS)

    Wiser, Ralph S.; Valencia, Matthew J

    2017-01-01

    Los Alamos National Laboratory states that its mission is ''To solve national security challenges through scientific excellence.'' The Science Undergraduate Laboratory Internship (SULI) programs exists to engage undergraduate students in STEM work by providing opportunity to work at DOE facilities. As an undergraduate mechanical engineering intern under the SULI program at Los Alamos during the fall semester of 2016, I had the opportunity to contribute to the mission of the Laboratory while developing skills in a STEM discipline. I worked with Technology Applications, an engineering group that supports non-proliferation, counter terrorism, and emergency response missions. This group specializes in tool design, weapons engineering, rapid prototyping, and mission training. I assisted with two major projects during my appointment Los Alamos. The first was a thermal source transportation unit, intended to safely contain a nuclear thermal source during transit. The second was a soil drying unit for use in nuclear postblast field sample collection. These projects have given me invaluable experience working alongside a team of professional engineers. Skills developed include modeling, simulation, group design, product and system design, and product testing.

  5. MMPI-2 Characteristics of the Old Order Amish: A Comparison of Clinical, Nonclinical, and United States Normative Samples

    Science.gov (United States)

    Knabb, Joshua J.; Vogt, Ronald G.; Newgren, Kevin P.

    2011-01-01

    In the current study, we investigated Minnesota Multiphasic Personality Inventory-2 (MMPI-2) characteristics in an Old Order Amish nonclinical sample (N = 84), comparing these data with both the United States normative sample (N = 2,600) and a sample of Old Order Amish outpatients (N = 136). Consistent with our hypothesis, the Old Order Amish…

  6. Data validation summary report for the 100-BC-5 Operable Unit Round 9 Groundwater Sampling. Revision 0

    International Nuclear Information System (INIS)

    Kearney, A.T.

    1996-03-01

    The information provided in this validation summary report includes chemical analyses of samples from 100-BC-5 Operable Unit Round 9 Groundwater sampling data. Data from this sampling event and their related quality assurance (QA) samples were reviewed and validated in accordance with Westinghouse Hanford Company (WHC) guidelines at the requested level. Sample analyses included metals, general chemistry, and radiochemistry. Sixty metals samples were analyzed by Quanterra Environmental Services (QES) and Lockheed Analytical Services (LAS). The metals samples were validated using WHC protocols specified in Data Validation Procedures for Chemical Analyses. All qualifiers assigned to the metals data were based on this guidance. The Table 1.1 lists the metals sample delivery group (SDG) that were validated for this sampling event

  7. Boat sampling and inservice inspections of the reactor pressure vessel weld No. 4 at Kozloduy NPP, Unit 1

    International Nuclear Information System (INIS)

    Cvitanovic, M.; Oreb, E.; Mudronja, V.; Zado, V.; Bezlaj, H.; Petkov, M.; Gledatchev, J.; Radomirski, S.; Ribarska, T.; Kroes, B.

    1999-01-01

    The paper deals with reactor pressure vessel (RPV) boat sampling performed at Kozloduy Nuclear Power Plant, Unit 1, from August to November 1996. Kozloduy NPP, Unit 1 has no reactor vessel material surveillance program. Changes in the material fracture toughness resulting from the fast neutron irradiation which cannot be monitored without removal of the vessel material. Therefore, the main objective of the project was to cut samples from the RPV wall in order to obtain samples of the RPV material for further structural analyses. The most critical area, i.e. weld No. 4 was determined as a location for boat sampling. Replication technique was applied in order to obtain precise determination of the weld geometry necessary for positioning of the cutting tool prior to boat sampling, and determination of divot depth left after boat sampling and grinding of sample sites. Boat sampling was performed by electrical discharge machining (EDM). Grinding of sample sites was implemented to minimize stress concentration effects on sample sites, to eliminate surface irregularities resulting from EDM process, and to eliminate recast layer on the surface of the EDM cut. Ultrasonic, liquid penetrant, magnetic particles, and visual examinations were performed after grinding to establish baseline data in the boat sampling area. The project preparation activities, apart from EDM process, and the site organization lead was entrusted to INETEC. The activities were funded by the PHARE program of the European Commission. (orig.)

  8. Sampling and Analysis Plan Update for Groundwater Monitoring 1100-EM-1 Operable Unit

    International Nuclear Information System (INIS)

    DR Newcomer

    1999-01-01

    This document updates the sampling and analysis plan (Department of Energy/Richland Operations--95-50) to reflect current groundwater monitoring at the 1100-EM-1Operable Unit. Items requiring updating included sampling and analysis protocol, quality assurance and quality control, groundwater level measurement procedure, and data management. The plan covers groundwater monitoring, as specified in the 1993 Record of Decision, during the 5-year review period from 1995 through 1999. Following the 5-year review period, groundwater-monitoring data will be reviewed by Environmental Protection Agency to evaluate the progress of natural attenuation of trichloroethylene. Monitored natural attenuation and institutional controls for groundwater use at the inactive Horn Rapids Landfill was the selected remedy specified in the Record of Decision

  9. Soil Sampling to Demonstrate Compliance with Department of Energy Radiological Clearance Requirements for the ALE Unit of the Hanford Reach National Monument

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Brad G.; Dirkes, Roger L.; Napier, Bruce A.

    2007-04-01

    The Hanford Reach National Monument consists of several units, one of which is the Fitzner/Eberhardt Arid Lands Ecology Reserve (ALE) Unit. This unit is approximately 311 km2 of shrub-steppe habitat located to the south and west of Highway 240. To fulfill internal U. S. Department of Energy (DOE) requirements prior to any radiological clearance of land, DOE must evaluate the potential for residual radioactive contamination on this land and determine compliance with the requirements of DOE Order 5400.5. Historical soil monitoring conducted on ALE indicated soil concentrations of radionuclides were well below the Authorized Limits. However, the historical sampling was done at a limited number of sampling locations. Therefore, additional soil sampling was conducted to determine if the concentrations of radionuclides in soil on the ALE Unit were below the Authorized Limits. This report contains the results of 50 additional soil samples. The 50 soil samples collected from the ALE Unit all had concentrations of radionuclides far below the Authorized Limits. The average concentrations for all detectable radionuclides were less than the estimated Hanford Site background. Furthermore, the maximum observed soil concentrations for the radionuclides included in the Authorized Limits would result in a potential annual dose of 0.14 mrem assuming the most probable use scenario, a recreational visitor. This potential dose is well below the DOE 100-mrem per year dose limit for a member of the public. Spatial analysis of the results indicated no observable statistically significant differences between radionuclide concentrations across the ALE Unit. Furthermore, the results of the biota dose assessment screen, which used the ResRad Biota code, indicated that the concentrations of radionuclides in ALE Unit soil pose no significant health risk to biota.

  10. Distribution of muscle fibre conduction velocity for representative samples of motor units in the full recruitment range of the tibialis anterior muscle.

    Science.gov (United States)

    Del Vecchio, A; Negro, F; Felici, F; Farina, D

    2018-02-01

    Motor units are recruited in an orderly manner according to the size of motor neurones. Moreover, because larger motor neurones innervate fibres with larger diameters than smaller motor neurones, motor units should be recruited orderly according to their conduction velocity (MUCV). Because of technical limitations, these relations have been previously tested either indirectly or in small motor unit samples that revealed weak associations between motor unit recruitment threshold (RT) and MUCV. Here, we analyse the relation between MUCV and RT for large samples of motor units. Ten healthy volunteers completed a series of isometric ankle dorsiflexions at forces up to 70% of the maximum. Multi-channel surface electromyographic signals recorded from the tibialis anterior muscle were decomposed into single motor unit action potentials, from which the corresponding motor unit RT, MUCV and action potential amplitude were estimated. Established relations between muscle fibre diameter and CV were used to estimate the fibre size. Within individual subjects, the distributions of MUCV and fibre diameters were unimodal and did not show distinct populations. MUCV was strongly correlated with RT (mean (SD) R 2  = 0.7 (0.09), P motor units), which supported the hypothesis that fibre diameter is associated with RT. The results provide further evidence for the relations between motor neurone and muscle fibre properties for large samples of motor units. The proposed methodology for motor unit analysis has also the potential to open new perspectives in the study of chronic and acute neuromuscular adaptations to ageing, training and pathology. © 2017 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  11. Sample Based Unit Liter Dose Estimates

    International Nuclear Information System (INIS)

    JENSEN, L.

    1999-01-01

    The Tank Waste Characterization Program has taken many core samples, grab samples, and auger samples from the single-shell and double-shell tanks during the past 10 years. Consequently, the amount of sample data available has increased, both in terms of quantity of sample results and the number of tanks characterized. More and better data is available than when the current radiological and toxicological source terms used in the Basis for Interim Operation (BIO) (FDH 1999) and the Final Safety Analysis Report (FSAR) (FDH 1999) were developed. The Nuclear Safety and Licensing (NS and L) organization wants to use the new data to upgrade the radiological and toxicological source terms used in the BIO and FSAR. The NS and L organization requested assistance in developing a statistically based process for developing the source terms. This report describes the statistical techniques used and the assumptions made to support the development of a new radiological source term for liquid and solid wastes stored in single-shell and double-shell tanks

  12. Low-impact sampling under an active solid low-level radioactive waste disposal unit using horizontal drilling technology

    International Nuclear Information System (INIS)

    Puglisi, C.V.; Vold, E.L.

    1995-01-01

    The purpose of this project was to determine the performance of the solid low-level radioactive waste (LLRW) disposal units located on a mesa top at TA-54, Area G, Los Alamos National Laboratory (LANL), Los Alamos, NM, and to provide in-situ (vadose zone) site characterization information to Area G's Performance Assessment. The vadose zone beneath an active disposal unit (DU 37), was accessed by utilizing low-impact, air-rotary horizontal drilling technology. Core samples were pulled, via wire-line core method, in 3 horizontal holes fanning out below DU 37 at approximately 5 foot intervals depending on recovery percentage. Samples were surveyed and prepared in-field following Environmental Restoration (ER) guidelines. Samples were transferred from the field to the CST-9 Radvan for initial radiological screening. Following screening, samples were delivered to CST-3 analytical lab for analyses including moisture content, 23 inorganics, 60 volatile organic compounds (VOC's), 68 semivolatile organic compounds (SVOC's), tritium, lead 210, radium 226 ampersand 228, cesium 137, isotopic plutonium, americium 241, strontium 90, isotopic uranium, and isotopic thorium. Other analyses included matric potential, alpha spectroscopy, gamma spectroscopy, and gross alpha/beta. The overall results of the analysis identified only tritium as having migrated from the DU. Am-241, Eu-152, and Pu-238 were possibly identified above background but the results are not definitive. Of all organics analysed for, only ethyl acetate was tentatively identified slightly above background. All inorganics were found to be well below regulatory limits. Based on the results of the above mentioned analyses, it was determined that Area G's disposal units are performing well and no significant liquid phase migration of contaminants has occurred

  13. Integrated sampling and analysis unit for the determination of sexual pheromones in environmental air using fabric phase sorptive extraction and headspace-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Alcudia-León, M Carmen; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel; Kabir, Abuzar; Furton, Kenneth G

    2017-03-10

    This article presents a novel unit that integrates for the first time air sampling and preconcentration based on the use of fabric phase sorptive extraction principles. The determination of Tuta absoluta sexual pheromone traces in environmental air has been selected as analytical problem. For this aim, a novel laboratory-built unit made up of commercial brass elements as holder of the sol-gel coated fabric extracting phase has been designed and optimized. The performance of the integrated unit was evaluated analyzing environmental air sampled in tomato crops. The unit can work under sampling and analysis mode which eliminates any need for sorptive phase manipulation prior to instrumental analysis. In the sampling mode, the unit can be connected to a sampling pump to pass the air through the sorptive phase at a controlled flow-rate. In the analysis mode, it is placed in the gas chromatograph autosampler without any instrumental modification. It also diminishes the risk of cross contamination between sampling and analysis. The performance of the new unit has been evaluated using the main components of the sexual pheromone of Tuta absoluta [(3E,8Z,11Z)-tetradecatrien-1-yl acetate and (3E,8Z)-tetradecadien-1-yl acetate] as model analytes. The limits of detection for both compounds resulted to be 1.6μg and 0.8μg, respectively, while the precision (expressed as relative standard deviation) was better than 3.7%. Finally, the unit has been deployed in the field to analyze a number of real life samples, some of them were found positive. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Sampling and analysis plan for remediation of Operable Unit 100-IU-3 waste site 600-104. Revision 1

    International Nuclear Information System (INIS)

    1997-08-01

    This sampling and analysis plan presents the rationale and strategy for the sampling and analysis activities to support remediation of 100-IU-3 Operable Unit waste site 600-104. The purpose of the proposed sampling and analysis activities is to demonstrate that time-critical remediation of the waste site for soil containing 2,4-Dichlorophenoxyacetic acid salts and esters (2,4-D) and dioxin/furan isomers at concentrations that exceed cleanup levels has been effective. This shall be accomplished by sampling various locations of the waste site before and after remediation, analyzing the samples, and comparing the results to action levels set by the Washington State Department of Ecology

  15. Sample Based Unit Liter Dose Estimates

    International Nuclear Information System (INIS)

    JENSEN, L.

    2000-01-01

    The Tank Waste Characterization Program has taken many core samples, grab samples, and auger samples from the single-shell and double-shell tanks during the past 10 years. Consequently, the amount of sample data available has increased, both in terms of quantity of sample results and the number of tanks characterized. More and better data is available than when the current radiological and toxicological source terms used in the Basis for Interim Operation (BIO) (FDH 1999a) and the Final Safety Analysis Report (FSAR) (FDH 1999b) were developed. The Nuclear Safety and Licensing (NS and L) organization wants to use the new data to upgrade the radiological and toxicological source terms used in the BIO and FSAR. The NS and L organization requested assistance in producing a statistically based process for developing the source terms. This report describes the statistical techniques used and the assumptions made to support the development of a new radiological source term for liquid and solid wastes stored in single-shell and double-shell tanks. The results given in this report are a revision to similar results given in an earlier version of the document (Jensen and Wilmarth 1999). The main difference between the results in this document and the earlier version is that the dose conversion factors (DCF) for converting μCi/g or μCi/L to Sv/L (sieverts per liter) have changed. There are now two DCFs, one based on ICRP-68 and one based on ICW-71 (Brevick 2000)

  16. Understanding the relationship between proactive and reactive aggression, and cyberbullying across United States and Singapore adolescent samples.

    Science.gov (United States)

    Ang, Rebecca P; Huan, Vivien S; Florell, Dan

    2014-01-01

    This study examined cyberbullying among adolescents across United States and Singapore samples. Specifically, the purpose of the investigation was to study the differential associations between proactive and reactive aggression, and cyberbullying across two cultures. A total of 425 adolescents from the United States (M age = 13 years) and a total of 332 adolescents from Singapore (M age = 14.2 years) participated in the study. Results of the moderator analyses suggested that nationality was not a moderator of the relationship between proactive aggression and cyberbullying, and between reactive aggression and cyberbullying. As expected, findings showed proactive aggression to be positively associated with cyberbullying, after controlling for reactive aggression, across both samples. Likewise, as hypothesized, reactive aggression and cyberbullying was not found to be significant after controlling for proactive aggression across both samples. Implications of these findings were discussed: (a) Proactive aggression is a possible risk factor for both bullying and cyberbullying; (b) proactive and reactive aggression could be argued to be distinct as they have different correlates-only proactive aggression contributed to cyberbullying after controlling for reactive aggression; (c) this research extends previous work and contributes toward cross-cultural work using similar and comparable measures across different samples; and (d) prevention and intervention programs targeted at proactive aggressive adolescents could adopt a two-pronged approach by changing mind sets, and by understanding and adopting a set of rules for Internet etiquette.

  17. Field Sampling Plan for the Operable Units 6-05 and 10-04 Remedial Action, Phase IV

    Energy Technology Data Exchange (ETDEWEB)

    R. Wells

    2006-11-14

    This Field Sampling Plan outlines the collection and analysis of samples in support of Phase IV of the Waste Area Group 10, Operable Units 6-05 and 10-04 remedial action. Phase IV addresses the remedial actions to areas with the potential for unexploded ordnance at the Idaho National Laboratory Site. These areas include portions of the Naval Proving Ground, the Arco High-Altitude Bombing Range, and the Twin Buttes Bombing Range. The remedial action consists of removal and disposal of ordnance by high-order detonation, followed by sampling to determine the extent, if any, of soil that might have been contaminated by the detonation activities associated with the disposal of ordnance during the Phase IV activities and explosives during the Phase II activities.

  18. Influence of management of variables, sampling zones and land units on LR analysis for landslide spatial prevision

    Directory of Open Access Journals (Sweden)

    R. Greco

    2013-09-01

    Full Text Available Several authors, according to different methodological approaches, have employed logistic Regression (LR, a multivariate statistical analysis adopted to assess the spatial probability of landslide, even though its fundamental principles have remained unaltered. This study aims at assessing the influence of some of these methodological approaches on the performance of LR, through a series of sensitivity analyses developed over a test area of about 300 km2 in Calabria (southern Italy. In particular, four types of sampling (1 – the whole study area; 2 – transects running parallel to the general slope direction of the study area with a total surface of about 1/3 of the whole study area; 3 – buffers surrounding the phenomena with a 1/1 ratio between the stable and the unstable area; 4 – buffers surrounding the phenomena with a 1/2 ratio between the stable and the unstable area, two variable coding modes (1 – grouped variables; 2 – binary variables, and two types of elementary land (1 – cells units; 2 – slope units units have been tested. The obtained results must be considered as statistically relevant in all cases (Aroc values > 70%, thus confirming the soundness of the LR analysis which maintains high predictive capacities notwithstanding the features of input data. As for the area under investigation, the best performing methodological choices are the following: (i transects produced the best results (0 P(y ≤ 93.4%; Aroc = 79.5%; (ii as for sampling modalities, binary variables (0 P(y ≤ 98.3%; Aroc = 80.7% provide better performance than ordinated variables; (iii as for the choice of elementary land units, slope units (0 P(y ≤ 100%; Aroc = 84.2% have obtained better results than cells matrix.

  19. Fluid sample collection and distribution system. [qualitative analysis of aqueous samples from several points

    Science.gov (United States)

    Brooks, R. L. (Inventor)

    1979-01-01

    A multipoint fluid sample collection and distribution system is provided wherein the sample inputs are made through one or more of a number of sampling valves to a progressive cavity pump which is not susceptible to damage by large unfiltered particles. The pump output is through a filter unit that can provide a filtered multipoint sample. An unfiltered multipoint sample is also provided. An effluent sample can be taken and applied to a second progressive cavity pump for pumping to a filter unit that can provide one or more filtered effluent samples. The second pump can also provide an unfiltered effluent sample. Means are provided to periodically back flush each filter unit without shutting off the whole system.

  20. Systematic Sampling and Cluster Sampling of Packet Delays

    OpenAIRE

    Lindh, Thomas

    2006-01-01

    Based on experiences of a traffic flow performance meter this papersuggests and evaluates cluster sampling and systematic sampling as methods toestimate average packet delays. Systematic sampling facilitates for exampletime analysis, frequency analysis and jitter measurements. Cluster samplingwith repeated trains of periodically spaced sampling units separated by randomstarting periods, and systematic sampling are evaluated with respect to accuracyand precision. Packet delay traces have been ...

  1. Acrolein and asthma attack prevalence in a representative sample of the United States adult population 2000-2009.

    Science.gov (United States)

    deCastro, B Rey

    2014-01-01

    Acrolein is an air toxic and highly potent respiratory irritant. There is little epidemiology available, but US EPA estimates that outdoor acrolein is responsible for about 75 percent of non-cancer respiratory health effects attributable to air toxics in the United States, based on the Agency's 2005 NATA (National-Scale Air Toxics Assessment) and acrolein's comparatively potent inhalation reference concentration of 0.02 µg/m3. Assess the association between estimated outdoor acrolein exposure and asthma attack reported by a representative cross-sectional sample of the adult United States population. NATA 2005 chronic outdoor acrolein exposure estimates at the census tract were linked with residences oif adults (≥18 years old) in the NHIS (National Health Interview Survey) 2000-2009 (n = 271,348 subjects). A sample-weighted logistic regression model characterized the association between the prevalence of reporting at least one asthma attack in the 12 months prior to survey interview and quintiles of exposure to outdoor acrolein, controlling for potential confounders. In the highest quintile of outdoor acrolein exposure (0.05-0.46 µg/m3), there was a marginally significant increase in the asthma attack pOR (prevalence-odds ratio [95% CI]  = 1.08 [0.98∶1.19]) relative to the lowest quintile. The highest quintile was also associated with a marginally significant increase in prevalence-odds (1.13 [0.98∶1.29]) in a model limited to never smokers (n = 153,820). Chronic exposure to outdoor acrolein of 0.05-0.46 µg/m3 appears to increase the prevalence-odds of having at least one asthma attack in the previous year by 8 percent in a representative cross-sectional sample of the adult United States population.

  2. Acrolein and asthma attack prevalence in a representative sample of the United States adult population 2000-2009.

    Directory of Open Access Journals (Sweden)

    B Rey deCastro

    Full Text Available BACKGROUND: Acrolein is an air toxic and highly potent respiratory irritant. There is little epidemiology available, but US EPA estimates that outdoor acrolein is responsible for about 75 percent of non-cancer respiratory health effects attributable to air toxics in the United States, based on the Agency's 2005 NATA (National-Scale Air Toxics Assessment and acrolein's comparatively potent inhalation reference concentration of 0.02 µg/m3. OBJECTIVES: Assess the association between estimated outdoor acrolein exposure and asthma attack reported by a representative cross-sectional sample of the adult United States population. METHODS: NATA 2005 chronic outdoor acrolein exposure estimates at the census tract were linked with residences oif adults (≥18 years old in the NHIS (National Health Interview Survey 2000-2009 (n = 271,348 subjects. A sample-weighted logistic regression model characterized the association between the prevalence of reporting at least one asthma attack in the 12 months prior to survey interview and quintiles of exposure to outdoor acrolein, controlling for potential confounders. RESULTS: In the highest quintile of outdoor acrolein exposure (0.05-0.46 µg/m3, there was a marginally significant increase in the asthma attack pOR (prevalence-odds ratio [95% CI]  = 1.08 [0.98∶1.19] relative to the lowest quintile. The highest quintile was also associated with a marginally significant increase in prevalence-odds (1.13 [0.98∶1.29] in a model limited to never smokers (n = 153,820. CONCLUSIONS: Chronic exposure to outdoor acrolein of 0.05-0.46 µg/m3 appears to increase the prevalence-odds of having at least one asthma attack in the previous year by 8 percent in a representative cross-sectional sample of the adult United States population.

  3. Sampling in practice

    DEFF Research Database (Denmark)

    Esbensen, Kim Harry; Petersen, Lars

    2005-01-01

    A basic knowledge of the Theory of Sampling (TOS) and a set of only eight sampling unit operations is all the practical sampler needs to ensure representativeness of samples extracted from all kinds of lots: production batches, - truckloads, - barrels, sub-division in the laboratory, sampling...... in nature and in the field (environmental sampling, forestry, geology, biology), from raw materials or manufactory processes etc. We here can only give a brief introduction to the Fundamental Sampling Principle (FSP) and these eight Sampling Unit Operations (SUO’s). Always respecting FSP and invoking only...... the necessary SUO’s (dependent on the practical situation) is the only prerequisite needed for eliminating all sampling bias and simultaneously minimizing sampling variance, and this is in addition a sure guarantee for making the final analytical results trustworthy. No reliable conclusions can be made unless...

  4. Groundwater quality data in 15 GAMA study units: results from the 2006–10 Initial sampling and the 2009–13 resampling of wells, California GAMA Priority Basin Project

    Science.gov (United States)

    Kent, Robert

    2015-08-31

    The Priority Basin Project (PBP) of the Groundwater Ambient Monitoring and Assessment (GAMA) program was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). From May 2004 to March 2012, the GAMA-PBP collected samples from more than 2,300 wells in 35 study units across the State. Selected wells in each study unit were sampled again approximately 3 years after initial sampling as part of an assessment of temporal trends in water quality by the GAMA-PBP. This triennial (every 3 years) trend sampling of GAMA-PBP study units concluded in December 2013. Fifteen of the study units, initially sampled between January 2006 and June 2010 and sampled a second time between April 2009 and April 2013 to assess temporal trends, are the subject of this report.

  5. Household Coverage of Fortified Staple Food Commodities in Rajasthan, India.

    Directory of Open Access Journals (Sweden)

    Grant J Aaron

    Full Text Available A spatially representative statewide survey was conducted in Rajasthan, India to assess household coverage of atta wheat flour, edible oil, and salt. An even distribution of primary sampling units were selected based on their proximity to centroids on a hexagonal grid laid over the survey area. A sample of n = 18 households from each of m = 252 primary sampling units PSUs was taken. Demographic data on all members of these households were collected, and a broader dataset was collected about a single caregiver and a child in the first 2 years of life. Data were collected on demographic and socioeconomic status; education; housing conditions; recent infant and child mortality; water, sanitation, and hygiene practices; food security; child health; infant and young child feeding practices; maternal dietary diversity; coverage of fortified staples; and maternal and child anthropometry. Data were collected from 4,627 households and the same number of caregiver/child pairs. Atta wheat flour was widely consumed across the state (83%; however, only about 7% of the atta wheat flour was classified as fortifiable, and only about 6% was actually fortified (mostly inadequately. For oil, almost 90% of edible oil consumed by households in the survey was classified as fortifiable, but only about 24% was fortified. For salt, coverage was high, with almost 85% of households using fortified salt and 66% of households using adequately fortified salt. Iodized salt coverage was also high; however, rural and poor population groups were less likely to be reached by the intervention. Voluntary fortification of atta wheat flour and edible oil lacked sufficient industry consolidation to cover significant portions of the population. It is crucial that appropriate delivery channels are utilized to effectively deliver essential micronutrients to at-risk population groups. Government distribution systems are likely the best means to accomplish this goal.

  6. Community-level influences on women's experience of intimate partner violence and terminated pregnancy in Nigeria: a multilevel analysis

    Directory of Open Access Journals (Sweden)

    Antai Diddy

    2012-11-01

    Full Text Available Abstract Background Intimate partner violence (IPV is a major public health problem with serious consequences for women’s physical, mental, sexual and reproductive health. Reproductive health outcomes such as unwanted and terminated pregnancies, fetal loss or child loss during infancy, non-use of family planning methods, and high fertility are increasingly recognized. However, little is known about the role of community influences on women's experience of IPV and its effect on terminated pregnancy, given the increased awareness of IPV being a product of social context. This study sought to examine the role of community-level norms and characteristics in the association between IPV and terminated pregnancy in Nigeria. Methods Multilevel logistic regression analyses were performed on nationally-representative cross-sectional data including 19,226 women aged 15–49 years in Nigeria. Data were collected by a stratified two-stage sampling technique, with 888 primary sampling units (PSUs selected in the first sampling stage, and 7,864 households selected through probability sampling in the second sampling stage. Results Women who had experienced physical IPV, sexual IPV, and any IPV were more likely to have terminated a pregnancy compared to women who had not experienced these IPV types. IPV types were significantly associated with factors reflecting relationship control, relationship inequalities, and socio-demographic characteristics. Characteristics of the women aggregated at the community level (mean education, justifying wife beating, mean age at first marriage, and contraceptive use were significantly associated with IPV types and terminated pregnancy. Conclusion Findings indicate the role of community influence in the association between IPV-exposure and terminated pregnancy, and stress the need for screening women seeking abortions for a history of abuse.

  7. Acrolein and Asthma Attack Prevalence in a Representative Sample of the United States Adult Population 2000 – 2009

    Science.gov (United States)

    deCastro, B. Rey

    2014-01-01

    Background Acrolein is an air toxic and highly potent respiratory irritant. There is little epidemiology available, but US EPA estimates that outdoor acrolein is responsible for about 75 percent of non-cancer respiratory health effects attributable to air toxics in the United States, based on the Agency's 2005 NATA (National-Scale Air Toxics Assessment) and acrolein's comparatively potent inhalation reference concentration of 0.02 µg/m3. Objectives Assess the association between estimated outdoor acrolein exposure and asthma attack reported by a representative cross-sectional sample of the adult United States population. Methods NATA 2005 chronic outdoor acrolein exposure estimates at the census tract were linked with residences oif adults (≥18 years old) in the NHIS (National Health Interview Survey) 2000 – 2009 (n = 271,348 subjects). A sample-weighted logistic regression model characterized the association between the prevalence of reporting at least one asthma attack in the 12 months prior to survey interview and quintiles of exposure to outdoor acrolein, controlling for potential confounders. Results In the highest quintile of outdoor acrolein exposure (0.05 – 0.46 µg/m3), there was a marginally significant increase in the asthma attack pOR (prevalence-odds ratio [95% CI]  = 1.08 [0.98∶1.19]) relative to the lowest quintile. The highest quintile was also associated with a marginally significant increase in prevalence-odds (1.13 [0.98∶1.29]) in a model limited to never smokers (n = 153,820). Conclusions Chronic exposure to outdoor acrolein of 0.05 – 0.46 µg/m3 appears to increase the prevalence-odds of having at least one asthma attack in the previous year by 8 percent in a representative cross-sectional sample of the adult United States population. PMID:24816802

  8. Assessment of the radionuclide composition of "hot particles" sampled in the Chernobyl nuclear power plant fourth reactor unit.

    Science.gov (United States)

    Bondarkov, Mikhail D; Zheltonozhsky, Viktor A; Zheltonozhskaya, Maryna V; Kulich, Nadezhda V; Maksimenko, Andrey M; Farfán, Eduardo B; Jannik, G Timothy; Marra, James C

    2011-10-01

    Fuel-containing materials sampled from within the Chernobyl Nuclear Power Plant (ChNPP) Unit 4 Confinement Shelter were spectroscopically studied for gamma and alpha content. Isotopic ratios for cesium, europium, plutonium, americium, and curium were identified, and the fuel burn-up in these samples was determined. A systematic deviation in the burn-up values based on the cesium isotopes in comparison with other radionuclides was observed. The studies conducted were the first ever performed to demonstrate the presence of significant quantities of 242Cm and 243Cm. It was determined that there was a systematic underestimation of activities of transuranic radionuclides in fuel samples from inside of the ChNPP Confinement Shelter, starting from 241Am (and going higher) in comparison with the theoretical calculations.

  9. Characteristics of fuel CRUD from Ringhals Unit 4. A comparison of CRUD samples from ultrasonic fuel cleaning and fuel scrape

    International Nuclear Information System (INIS)

    Chen, Jiaxin; Eskhult, Jonas; Marks, Chuck; Dingee, John; Bengtsson, Bernt; Wells, Daniel

    2014-01-01

    The characteristics and behaviour of PWR fuel CRUD are closely related to plant radiation field build-up and the risks of CRUD-Induced Power Shifts (CIPS, previously AOA) and CRUD-Induced Localized Corrosion (CILC). At Ringhals NPP fuel scrape technology has frequently been used to collect fuel CRUD samples as a part of plant water chemistry monitoring programs. In 2012, high efficiency ultrasonic fuel cleaning (HE-UFC) technology was first used at Ringhals Unit 4 to reduce the risk of CIPS, which was expected to increase due to steam generator replacement and a subsequent power uprate. In the HE-UFC system a “first-of-a-kind” CRUD sampling system was installed for collecting fuel CRUD. It is of interest to compare the fuel CRUD samples collected by the two different CRUD sampling methods and to understand if HE-UFC crud sampling could be used to replace or supplement the fuel scrape method. This paper presents some preliminary results on isotopic compositions, elemental compositions, and phase compositions of fuel CRUD samples collected from similar fuel rods and assemblies by both methods during the 2012 refueling outage, one cycle after steam generator replacement at Ringhals Unit 4. The results show that the characteristics of fuel CRUD sampled by HE-UFC and fuel scrape, although not always identical, were similar or correlated to some extent in terms of weight ratios of Ni to Fe and Cr to Fe as well as specific activities of Co-58, Co-60 and Cr-51. However, due to the limited experience with the HE-UFC sampling method, more consideration is required if the statistical significance of the obtained data and indications are to be verified. (author)

  10. Validation of the abbreviated Radon Progeny Integrating Sampling Unit (RPISU) method for Mesa County, Colorado

    International Nuclear Information System (INIS)

    Langner, G.H. Jr.

    1987-06-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center at the DOE Grand Junction, Colorado, Projects Office to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Indoor radon-daughter concentration measurements are made to determine whether a structure is in need of remedial action. The Technical Measurements Center conducted this study to validate an abbreviated Radon Progeny Integrated Sampling Unit (RPISU) method of making indoor radon-daughter measurements to determine whether a structure has a radon-daughter concentration (RDC) below the levels specified in various program standards. The Technical Measurements Center established a criterion against which RDC measurements made using the RPISU sampling method are evaluated to determine if sampling can be terminated or whether further measurements are required. This abbreviated RPISU criterion was tested against 317 actual sets of RPISU data from measurements made over an eight-year period in Mesa County, Colorado. The data from each location were tested against a standard that was assumed to be the same as the actual annual average RDC from that location. At only two locations was the criterion found to fail. Using the abbreviated RPISU method, only 0.6% of locations sampled can be expected to be falsely indicated as having annual average RDC levels below a given standard

  11. Effects of Childhood Adversity on Bullying and Cruelty to Animals in the United States: Findings from a National Sample

    Science.gov (United States)

    Vaughn, Michael G.; Fu, Qiang; Beaver, Kevin M.; DeLisi, Matt; Perron, Brian E.; Howard, Matthew O.

    2011-01-01

    This study examined effects of type of and cumulative burden of childhood adversities on bullying and cruelty to animals in the United States. Data were derived from Waves I and II of the National Epidemiologic Survey on Alcohol and Related Conditions, a nationally representative sample of U.S. adults. Structured psychiatric interviews were…

  12. [New container of sample: role in the reduction of bacterial contamination of standard platelet units].

    Science.gov (United States)

    Fehri, S; Tazi, I; Loukhmass, L; Benchemsi, N

    2006-12-01

    Bacterial contamination of unstable blood products constitutes today the most frequent infectious risk transmitted by blood transfusion. Platelet concentrates are often incrimineted. As responsible germs are in general of cutaneous origin, a sample procedure with diversion of the first 20 ml during blood donation is studied. The aim of this study is to evaluate the results of this technique on bacterial contamination rate of standard platelet units prepared at the regional blood transfusion center in Casablanca. A comparative study of two types of sample pockets is made: 500 Standard Platelet concentrates (CPS) are prepared after collection using standard triple bags (Baxter) (group 1) and 560 pockets of CPS were prepared after collection using triple bags with Sample Diversion Pouch sampling system for elimination of the first 20 ml of donation (Macopharma and Terumo) (group 2). The skin was disinfected in two times with alcohol 70%. The bacteriological study was made in the two groups at the third day of conservation. Six CPS of group 1 were contaminated, of which five were staphylococci coagulase negative and one bacillus sp. Six CPS of group 2 were contaminated, of which five were staphylococci coagulase negative and one staphylococcus aureus. The bacteria isolated were those of cutaneous flora at 100%. Diversion of first 20 ml of blood donation results in a 16.6% reduction in bacterial contamination of CPS (P>0.05). The non-significant reduction in the prevalence of the bacterial infection of CP formulates the problem of the indication of the sampling devices with derivation of first 20 ml during blood collection.

  13. Amphiphilic mediated sample preparation for micro-flow cytometry

    Science.gov (United States)

    Clague, David S [Livermore, CA; Wheeler, Elizabeth K [Livermore, CA; Lee, Abraham P [Irvine, CA

    2009-03-17

    A flow cytometer includes a flow cell for detecting the sample, an oil phase in the flow cell, a water phase in the flow cell, an oil-water interface between the oil phase and the water phase, a detector for detecting the sample at the oil-water interface, and a hydrophobic unit operatively connected to the sample. The hydrophobic unit is attached to the sample. The sample and the hydrophobic unit are placed in an oil and water combination. The sample is detected at the interface between the oil phase and the water phase.

  14. Mobile units to hydro geochemistry characterization

    International Nuclear Information System (INIS)

    Gomez, P.; Martinez, B.; Turrero, M.J.

    1994-01-01

    This report shows the mobile units for hydro geochemical studies. The authors analyze the work of mobile unit and the cars that conform the unit: Sampling car and analysis car: The sampling and equipment are took into account as well

  15. Integrated sampling and analysis plan for samples measuring >10 mrem/hour

    International Nuclear Information System (INIS)

    Haller, C.S.

    1992-03-01

    This integrated sampling and analysis plan was prepared to assist in planning and scheduling of Hanford Site sampling and analytical activities for all waste characterization samples that measure greater than 10 mrem/hour. This report also satisfies the requirements of the renegotiated Interim Milestone M-10-05 of the Hanford Federal Facility Agreement and Consent Order (the Tri-Party Agreement). For purposes of comparing the various analytical needs with the Hanford Site laboratory capabilities, the analytical requirements of the various programs were normalized by converting required laboratory effort for each type of sample to a common unit of work, the standard analytical equivalency unit (AEU). The AEU approximates the amount of laboratory resources required to perform an extensive suite of analyses on five core segments individually plus one additional suite of analyses on a composite sample derived from a mixture of the five core segments and prepare a validated RCRA-type data package

  16. Two sampling techniques for game meat

    OpenAIRE

    van der Merwe, Maretha; Jooste, Piet J.; Hoffman, Louw C.; Calitz, Frikkie J.

    2013-01-01

    A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g) and square centimetres (cm2) for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12) that statistically proved the two measuring units correlated. The two sampling...

  17. Sexual orientation and future parenthood in a 2011-2013 nationally representative United States sample.

    Science.gov (United States)

    Riskind, Rachel G; Tornello, Samantha L

    2017-09-01

    Previous researchers have found evidence for differences in parenting goals between lesbian and gay people and their heterosexual peers. However, no previous research has quantified the parenting goals of bisexual people or evaluated parenting goals as a function of sexual partner gender. In addition, political and social climates for sexual minority people had improved rapidly since the last representative data on lesbian and gay peoples' plans for parenthood were collected. We analyzed data from 3,941 childless lesbian, gay, bisexual, and heterosexual participants from the 2011-2013 National Survey of Family Growth (NSFG; United States Department of Health and Human Services, Centers for Disease Control and Prevention, National Center for Health Statistics, 2014), a nationally representative sample of United States residents aged 15 to 44 years. We found that statistically significant, within-gender sexual orientation differences in parenting plans persist, despite social and legal changes. Consistent with hypotheses, bisexual men's parenting desires and intentions were similar to those of their heterosexual male peers and different from those of their gay male peers, while bisexual women's reports were more mixed. Also consistent with hypotheses, the gender of the most recent sexual partner was a strong predictor of parenting goals. We discuss implications for mental and reproductive health-care providers, attorneys, social workers, and others who interact with sexual minority adults. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. Financial management skills are associated with food insecurity in a sample of households with children in the United States.

    Science.gov (United States)

    Gundersen, Craig G; Garasky, Steven B

    2012-10-01

    Food insecurity is one of the leading public health challenges facing children in the United States today. Reducing food insecurity and its attendant consequences requires an understanding of the determinants of food insecurity. Although previous work has greatly advanced our understanding of these determinants, the role of one of the oft-speculated important determinants of food insecurity, household financial management skills, has not been considered. To address this research lacuna, we use a recently conducted survey, the Survey of Household Finances and Childhood Obesity, that has information on specific financial management practices, impressions of financial management skills, and households' food insecurity. The sample included 904 households with children. Within this sample, 19.3% were food insecure and, for our central financial management skill variable, the mean value was 3.55 on a 5-point scale. Probit regression models estimated the probability of a household being food insecure as conditional on financial management skills and other covariates. We found a large and significant inverse relationship between a respondent's use of specific financial management practices and food insecurity and between a respondent's confidence in his or her financial management skills and food insecurity. That is, households with greater financial management abilities are less likely to be food insecure. This finding also holds when the sample is restricted to households with incomes <200% of the poverty line. These results suggest that improving households' financial management skills has the potential to reduce food insecurity in the United States.

  19. Demonstration/Validation of Incremental Sampling at Two Diverse Military Ranges and Development of an Incremental Sampling Tool

    Science.gov (United States)

    2010-06-01

    Sampling (MIS)? • Technique of combining many increments of soil from a number of points within exposure area • Developed by Enviro Stat (Trademarked...Demonstrating a reliable soil sampling strategy to accurately characterize contaminant concentrations in spatially extreme and heterogeneous...into a set of decision (exposure) units • One or several discrete or small- scale composite soil samples collected to represent each decision unit

  20. 7 CFR 52.775 - Sample unit size.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946... extraneous material—The total contents of each container in the sample. Factors of Quality ...

  1. Aquatic invertebrate sampling at selected outfalls in Operable Unit 1082; Technical areas 9, 11, 16 and 22

    Energy Technology Data Exchange (ETDEWEB)

    Cross, S.

    1995-09-01

    The Ecological Studies Team (EST) of ESH-20 at Los Alamos National Laboratory conducted preliminary aquatic sampling at outfalls within Operable Unit 1082 and nearby natural waterways. Eleven outfalls were sampled a total of eighteen times. Three natural waterways (upper Pajarito Canyon, Starmer`s Gulch, and Bulldog Spring) in the vicinity were sampled a total of six times. At most sites, EST recorded hydrological condition, physico-chemical parameters, wildlife uses, and vegetation. At each outfall with water and each natural waterway, EST collected an aquatic invertebrate sample which was analyzed by taxa composition, Wilhm`s biodiversity index, the community tolerance quotient (CTQ), and density. The physico-chemical parameters at most outfalls and natural waterways fell within the normal range of natural waters in the area. However, the outfalls are characterized by low biodiversity and severely stressed communities composed of a restricted number of taxa. The habitat at the other outfalls could probably support well-developed aquatic communities if sufficient water was available. At present, the hydrology at these outfalls is too slight and/or sporadic to support such a community in the foreseeable future. In contrast to the outfalls, the natural waterways of the area had greater densities of aquatic invertebrates, higher biodiversities, and lower CTQs.

  2. Quantitative portable gamma spectroscopy sample analysis for non-standard sample geometries

    International Nuclear Information System (INIS)

    Enghauser, M.W.; Ebara, S.B.

    1997-01-01

    Utilizing a portable spectroscopy system, a quantitative method for analysis of samples containing a mixture of fission and activation products in nonstandard geometries was developed. The method can be used with various sample and shielding configurations where analysis on a laboratory based gamma spectroscopy system is impractical. The portable gamma spectroscopy method involves calibration of the detector and modeling of the sample and shielding to identify and quantify the radionuclides present in the sample. The method utilizes the intrinsic efficiency of the detector and the unattenuated gamma fluence rate at the detector surface per unit activity from the sample to calculate the nuclide activity and Minimum Detectable Activity (MDA). For a complex geometry, a computer code written for shielding applications (MICROSHIELD) is utilized to determine the unattenuated gamma fluence rate per unit activity at the detector surface. Lastly, the method is only applicable to nuclides which emit gamma rays and cannot be used for pure beta emitters. In addition, if sample self absorption and shielding is significant, the attenuation will result in high MDA's for nuclides which solely emit low energy gamma rays. The following presents the analysis technique and presents verification results demonstrating the accuracy of the method

  3. Uniform Sampling of the Infinite Noncooperative Game on Unit Hypercube and Reshaping Ultimately Multidimensional Matrices of Player’s Payoff Values

    Directory of Open Access Journals (Sweden)

    Romanuke Vadim

    2015-07-01

    Full Text Available The paper suggests a method of obtaining an approximate solution of the infinite noncooperative game on the unit hypercube. The method is based on sampling uniformly the players’ payoff functions with the constant step along each of the hypercube dimensions. The author states the conditions for a sufficiently accurate sampling and suggests the method of reshaping the multidimensional matrix of the player’s payoff values, being the former player’s payoff function before its sampling, into a matrix with minimally possible number of dimensions, where also maintenance of one-to-one indexing has been provided. Requirements for finite NE-strategy from NE (Nash equilibrium solution of the finite game as the initial infinite game approximation are given as definitions of the approximate solution consistency. The approximate solution consistency ensures its relative independence upon the sampling step within its minimal neighborhood or the minimally decreased sampling step. The ultimate reshaping of multidimensional matrices of players’ payoff values to the minimal number of dimensions, being equal to the number of players, stimulates shortened computations.

  4. Prehistoric spatial patterning and subsistence studies: Archaeological investigations at Sample Unit U19arP4, Nevada Test Site, Nye County, Nevada

    International Nuclear Information System (INIS)

    Johnson, W.G.; DuBarton, A.; Edwards, S.; Drollinger, H.

    1992-01-01

    This report documents the methods and results of archaeological investigations at Sample Unit U19arP4 on Pahute Mesa at the Nevada Test Site (NTS). Eight sites were located there: four lithic artifact scatters (26NY1370, 26NY1372, 26NY3666 and 26NY3667), two temporary camps (26NY3665 and 26NY5418), one artifact locality (26NY5419), and one quarry (26NY3664). One of the lithic scatters, 26NY3667, incorporated a previously recorded rock ring, 26NY1371, that could not be relocated during subsequent investigations. Surface artifacts were collected from all but two of the sites, 26NY1370 and 26NY1372. The data retrieved from these investigations include over one thousand artifacts, such as projectile points, bifaces, debitage, groundstone, and pottery. The temporally diagnostic materials indicate periodic use of Sample Unit U19arP4 from the Middle Archaic to the Shoshonean period

  5. 7 CFR 52.38a - Definitions of terms applicable to statistical sampling.

    Science.gov (United States)

    2010-01-01

    ... the number of defects (or defectives), which exceed the sample unit tolerance (“T”), in a series of... accumulation of defects (or defectives) allowed to exceed the sample unit tolerance (“T”) in any sample unit or consecutive group of sample units. (ii) CuSum value. The accumulated number of defects (or defectives) that...

  6. Groundwater-quality data in seven GAMA study units: results from initial sampling, 2004-2005, and resampling, 2007-2008, of wells: California GAMA Program Priority Basin Project

    Science.gov (United States)

    Kent, Robert; Belitz, Kenneth; Fram, Miranda S.

    2014-01-01

    The Priority Basin Project (PBP) of the Groundwater Ambient Monitoring and Assessment (GAMA) Program was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The GAMA-PBP began sampling, primarily public supply wells in May 2004. By the end of February 2006, seven (of what would eventually be 35) study units had been sampled over a wide area of the State. Selected wells in these first seven study units were resampled for water quality from August 2007 to November 2008 as part of an assessment of temporal trends in water quality by the GAMA-PBP. The initial sampling was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within the seven study units. In the 7 study units, 462 wells were selected by using a spatially distributed, randomized grid-based method to provide statistical representation of the study area. Wells selected this way are referred to as grid wells or status wells. Approximately 3 years after the initial sampling, 55 of these previously sampled status wells (approximately 10 percent in each study unit) were randomly selected for resampling. The seven resampled study units, the total number of status wells sampled for each study unit, and the number of these wells resampled for trends are as follows, in chronological order of sampling: San Diego Drainages (53 status wells, 7 trend wells), North San Francisco Bay (84, 10), Northern San Joaquin Basin (51, 5), Southern Sacramento Valley (67, 7), San Fernando–San Gabriel (35, 6), Monterey Bay and Salinas Valley Basins (91, 11), and Southeast San Joaquin Valley (83, 9). The groundwater samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], pesticides, and pesticide degradates), constituents of special interest (perchlorate, N

  7. Large sample NAA of a pottery replica utilizing thermal neutron flux at AHWR critical facility and X-Z rotary scanning unit

    International Nuclear Information System (INIS)

    Acharya, R.; Dasari, K.B.; Pujari, P.K.; Swain, K.K.; Shinde, A.D.; Reddy, A.V.R.

    2013-01-01

    Large sample neutron activation analysis (LSNAA) of a clay pottery replica from Peru was carried out using low neutron flux graphite reflector position of Advanced Heavy Water Reactor (AHWR) critical facility. This work was taken up as a part of inter-comparison exercise under IAEA CRP on LSNAA of archaeological objects. Irradiated large size sample, placed on an X-Z rotary scanning unit, was assayed using a 40% relative efficiency HPGe detector. The k 0 -based internal monostandard NAA (IM-NAA) in conjunction with insitu relative detection efficiency was used to calculate concentration ratios of 12 elements with respect to Na. Analyses of both small and large size samples were carried out to check homogeneity and to arrive at absolute concentrations. (author)

  8. Public Use Microdata Samples (PUMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — Public Use Microdata Samples (PUMS) are computer-accessible files containing records for a sample of housing units, with information on the characteristics of each...

  9. The Association between Mental Health and Violence among a Nationally Representative Sample of College Students from the United States.

    Science.gov (United States)

    Schwartz, Joseph A; Beaver, Kevin M; Barnes, J C

    2015-01-01

    Recent violent attacks on college campuses in the United States have sparked discussions regarding the prevalence of psychiatric disorders and the perpetration of violence among college students. While previous studies have examined the potential association between mental health problems and violent behavior, the overall pattern of findings flowing from this literature remain mixed and no previous studies have examined such associations among college students. The current study makes use of a nationally representative sample of 3,929 college students from the National Epidemiologic Study on Alcohol and Related Conditions (NESARC) to examine the prevalence of seven violent behaviors and 19 psychiatric disorder diagnoses tapping mood, anxiety, personality, and substance use disorders. Associations between individual and composite psychiatric disorder diagnoses and violent behaviors were also examined. Additional analyses were adjusted for the comorbidity of multiple psychiatric diagnoses. The results revealed that college students were less likely to have engaged in violent behavior relative to the non-student sample, but a substantial portion of college students had engaged in violent behavior. Age- and sex-standardized prevalence rates indicated that more than 21% of college students reported at least one violent act. In addition, more than 36% of college students had at least one diagnosable psychiatric disorder. Finally, the prevalence of one or more psychiatric disorders significantly increased the odds of violent behavior within the college student sample. These findings indicate that violence and psychiatric disorders are prevalent on college campuses in the United States, though perhaps less so than in the general population. In addition, college students who have diagnosable psychiatric disorders are significantly more likely to engage in various forms of violent behavior.

  10. Sample Length Affects the Reliability of Language Sample Measures in 3-Year-Olds: Evidence from Parent-Elicited Conversational Samples

    Science.gov (United States)

    Guo, Ling-Yu; Eisenberg, Sarita

    2015-01-01

    Purpose: The goal of this study was to investigate the extent to which sample length affected the reliability of total number of words (TNW), number of different words (NDW), and mean length of C-units in morphemes (MLCUm) in parent-elicited conversational samples for 3-year-olds. Method: Participants were sixty 3-year-olds. A 22-min language…

  11. The influence of sampling unit size and spatial arrangement patterns on neighborhood-based spatial structure analyses of forest stands

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H.; Zhang, G.; Hui, G.; Li, Y.; Hu, Y.; Zhao, Z.

    2016-07-01

    Aim of study: Neighborhood-based stand spatial structure parameters can quantify and characterize forest spatial structure effectively. How these neighborhood-based structure parameters are influenced by the selection of different numbers of nearest-neighbor trees is unclear, and there is some disagreement in the literature regarding the appropriate number of nearest-neighbor trees to sample around reference trees. Understanding how to efficiently characterize forest structure is critical for forest management. Area of study: Multi-species uneven-aged forests of Northern China. Material and methods: We simulated stands with different spatial structural characteristics and systematically compared their structure parameters when two to eight neighboring trees were selected. Main results: Results showed that values of uniform angle index calculated in the same stand were different with different sizes of structure unit. When tree species and sizes were completely randomly interspersed, different numbers of neighbors had little influence on mingling and dominance indices. Changes of mingling or dominance indices caused by different numbers of neighbors occurred when the tree species or size classes were not randomly interspersed and their changing characteristics can be detected according to the spatial arrangement patterns of tree species and sizes. Research highlights: The number of neighboring trees selected for analyzing stand spatial structure parameters should be fixed. We proposed that the four-tree structure unit is the best compromise between sampling accuracy and costs for practical forest management. (Author)

  12. Coupling methods for multistage sampling

    OpenAIRE

    Chauvet, Guillaume

    2015-01-01

    Multistage sampling is commonly used for household surveys when there exists no sampling frame, or when the population is scattered over a wide area. Multistage sampling usually introduces a complex dependence in the selection of the final units, which makes asymptotic results quite difficult to prove. In this work, we consider multistage sampling with simple random without replacement sampling at the first stage, and with an arbitrary sampling design for further stages. We consider coupling ...

  13. Characterization of a clinical unit for digital radiography based on irradiation side sampling technology

    Energy Technology Data Exchange (ETDEWEB)

    Rivetti, Stefano [Fisica Medica, Ospedale di Sassuolo S.p.A., 41049 Sassuolo (Italy); Lanconelli, Nico [Alma Mater Studiorum, Physics Department, University of Bologna, 40127 Bologna (Italy); Bertolini, Marco; Nitrosi, Andrea [Medical Physics Unit, Azienda Ospedaliera ASMN, Istituto di Ricovero e Cura a Carattere Scientifico, 42123 Reggio Emilia (Italy); Burani, Aldo [Ospedale di Sassuolo S.p.A., 41049 Sassuolo (Italy)

    2013-10-15

    Purpose: A characterization of a clinical unit for digital radiography (FUJIFILM FDR D-EVO) is presented. This system is based on the irradiation side sampling (ISS) technology and can be equipped with two different scintillators: one traditional gadolinium-oxysulphide phosphor (GOS) and a needle structured cesium iodide (CsI) phosphor panel.Methods: The characterization was achieved in terms of response curve, modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE), and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). For both scintillation screens the authors accomplished the measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9.Results: At the Nyquist frequency (3.33 lp/mm) the MTF is about 35% and 25% for CsI and GOS detectors, respectively. The CsI scintillator has better noise properties than the GOS screen in almost all the conditions. This is particularly true for low-energy beams, where the noise for the GOS system can go up to a factor 2 greater than that found for CsI. The DQE of the CsI detector reaches a peak of 60%, 60%, 58%, and 50% for the RQA3, RQA5, RQA7, and RQA9 beams, respectively, whereas for the GOS screen the maximum DQE is 40%, 44%, 44%, and 35%. The contrast-detail analysis confirms that in the majority of cases the CsI scintillator is able to provide improved outcomes to those obtained with the GOS screen.Conclusions: The limited diffusion of light produced by the ISS reading makes possible the achievement of very good spatial resolution. In fact, the MTF of the unit with the CsI panel is only slightly lower to that achieved with direct conversion detectors. The combination of very good spatial resolution, together with the good noise properties reached with the CsI screen, allows achieving DQE on average about 1.5 times greater than that obtained with GOS. In fact, the DQE of unit equipped with CsI is comparable to the best

  14. Short communication prevalence of susceptibility to etravirine by genotype and phenotype in samples received for routine HIV type 1 resistance testing in the United States.

    Science.gov (United States)

    Picchio, Gaston; Vingerhoets, Johan; Tambuyzer, Lotke; Coakley, Eoin; Haddad, Mojgan; Witek, James

    2011-12-01

    Abstract The prevalence of susceptibility to etravirine was investigated among clinical samples submitted for routine clinical testing in the United States using two separate weighted genotypic scoring systems. The presence of etravirine mutations and susceptibility to etravirine by phenotype of clinical samples from HIV-1-infected patients, submitted to Monogram Biosciences for routine resistance testing between June 2008 and June 2009, were analyzed. Susceptibility by genotype was determined using the Monogram and Tibotec etravirine-weighted genotypic scoring systems, with scores of ≤3 and ≤2, respectively, indicating full susceptibility. Susceptibility by phenotype was determined using the PhenoSense HIV assay, with lower and higher clinical cut-offs of 2.9 and 10, respectively. The frequency of individual etravirine mutations and the impact of the K103N mutation on susceptibility to etravirine by genotype were also determined. Among the 5482 samples with ≥1 defined nonnucleoside reverse transcriptase inhibitor (NNRTI) mutations associated with resistance, 67% were classed as susceptible to etravirine by genotype by both scoring systems. Susceptibility to etravirine by phenotype was higher (76%). The proportion of first-generation NNRTI-resistant samples with (n=3598) and without (n=1884) K103N with susceptibility to etravirine by genotype was 77% and 49%, respectively. Among samples susceptible to first-generation NNRTIs (n=9458), >99% of samples were susceptible to etravirine by phenotype (FC <2.9); the remaining samples had FC ≥2.9-10. In summary, among samples submitted for routine clinical testing in the United States, a high proportion of samples with first-generation NNRTI resistance was susceptible to etravirine by genotype and phenotype. A higher proportion of NNRTI-resistant samples with K103N than without was susceptible to etravirine.

  15. Proposing an Empirically Justified Reference Threshold for Blood Culture Sampling Rates in Intensive Care Units

    Science.gov (United States)

    Castell, Stefanie; Schwab, Frank; Geffers, Christine; Bongartz, Hannah; Brunkhorst, Frank M.; Gastmeier, Petra; Mikolajczyk, Rafael T.

    2014-01-01

    Early and appropriate blood culture sampling is recommended as a standard of care for patients with suspected bloodstream infections (BSI) but is rarely taken into account when quality indicators for BSI are evaluated. To date, sampling of about 100 to 200 blood culture sets per 1,000 patient-days is recommended as the target range for blood culture rates. However, the empirical basis of this recommendation is not clear. The aim of the current study was to analyze the association between blood culture rates and observed BSI rates and to derive a reference threshold for blood culture rates in intensive care units (ICUs). This study is based on data from 223 ICUs taking part in the German hospital infection surveillance system. We applied locally weighted regression and segmented Poisson regression to assess the association between blood culture rates and BSI rates. Below 80 to 90 blood culture sets per 1,000 patient-days, observed BSI rates increased with increasing blood culture rates, while there was no further increase above this threshold. Segmented Poisson regression located the threshold at 87 (95% confidence interval, 54 to 120) blood culture sets per 1,000 patient-days. Only one-third of the investigated ICUs displayed blood culture rates above this threshold. We provided empirical justification for a blood culture target threshold in ICUs. In the majority of the studied ICUs, blood culture sampling rates were below this threshold. This suggests that a substantial fraction of BSI cases might remain undetected; reporting observed BSI rates as a quality indicator without sufficiently high blood culture rates might be misleading. PMID:25520442

  16. Sampling and analysis plan for treatment water and creek water for the Lower East Fork Poplar Creek Operable Unit, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    This document provides the Environmental Restoration Program with information about the methodology, organizational structure, quality assurance and health and safety practices to be employed during the water sampling and analysis activities associated with the remediation of the Lower East Fork Poplar Creek Operable Unit during remediation of the National Oceanic and Atmospheric Administration and Bruner sites.

  17. Sampling and analysis plan for treatment water and creek water for the Lower East Fork Poplar Creek Operable Unit, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1996-04-01

    This document provides the Environmental Restoration Program with information about the methodology, organizational structure, quality assurance and health and safety practices to be employed during the water sampling and analysis activities associated with the remediation of the Lower East Fork Poplar Creek Operable Unit during remediation of the National Oceanic and Atmospheric Administration and Bruner sites

  18. Efficiency of Executive Function: A Two-Generation Cross-Cultural Comparison of Samples From Hong Kong and the United Kingdom.

    Science.gov (United States)

    Ellefson, Michelle R; Ng, Florrie Fei-Yin; Wang, Qian; Hughes, Claire

    2017-05-01

    Although Asian preschoolers acquire executive functions (EFs) earlier than their Western counterparts, little is known about whether this advantage persists into later childhood and adulthood. To address this gap, in the current study we gave four computerized EF tasks (providing measures of inhibition, working memory, cognitive flexibility, and planning) to a large sample ( n = 1,427) of 9- to 16-year-olds and their parents. All participants lived in either the United Kingdom or Hong Kong. Our findings highlight the importance of combining developmental and cultural perspectives and show both similarities and contrasts across sites. Specifically, adults' EF performance did not differ between the two sites; age-related changes in executive function for both the children and the parents appeared to be culturally invariant, as did a modest intergenerational correlation. In contrast, school-age children and young adolescents in Hong Kong outperformed their United Kingdom counterparts on all four EF tasks, a difference consistent with previous findings from preschool children.

  19. Trends in darunavir resistance-associated mutations and phenotypic resistance in commercially tested United States clinical samples between 2006 and 2012.

    Science.gov (United States)

    Lathouwers, Erkki; Gupta, Soumi; Haddad, Mojgan; Paquet, Agnes; de Meyer, Sandra; Baugh, Bryan

    2015-06-01

    HIV-1 samples submitted by clinicians from the United States for routine drug susceptibility testing (PhenoSense GT) were evaluated for genotypic and phenotypic resistance to darunavir and other protease inhibitors (PIs). Among these samples (Monogram Biosciences database January 2006-June 2012; N=78,843), isolates harboring zero IAS-USA darunavir resistance-associated mutations (RAMs) increased from 77.7% in 2006 to 92.8% through the first half of 2012 (H1 2012; upward trend, p=0.0008); a downward trend seen for samples with three or more darunavir RAMs (7.5% in 2006 and 2.6% in H1 2012; p=0.002). Among samples with any PI resistance (N=15,932), samples harboring zero darunavir RAMs gradually increased (39.9% in 2006 vs. 55.0% in H1 2012; upward trend, p=0.005), but three or more darunavir RAMs did not change over time (21.7% in 2006 and 19.2% in H1 2012; p=0.27). During this period, the frequency of the 11 individual darunavir RAMs (IAS-USA 2011 list) decreased among all samples. The frequency of each darunavir RAM in PI-resistant samples decreased or remained relatively stable. The prevalence of samples with phenotypic resistance to darunavir (partial-to-full) decreased over time in all samples (8.2% in 2006 vs. 2.3% in H1 2012), as did resistance to other PIs (p<0.006 for all PIs). Phenotypic resistance to darunavir and other PIs also decreased in PI-resistant samples (darunavir: 23.9% in 2006 vs. 17.1% in H1 2012; p<0.013 for all PIs). Since approval of darunavir in 2006, there was a significant decrease in prevalence of samples with genotypic and phenotypic resistance to darunavir in commercially tested HIV-1 isolates. Furthermore, the prevalence of phenotypic resistance to darunavir was lower than all other PIs.

  20. An antithetic variate to facilitate upper-stem height measurements for critical height sampling with importance sampling

    Science.gov (United States)

    Thomas B. Lynch; Jeffrey H. Gove

    2013-01-01

    Critical height sampling (CHS) estimates cubic volume per unit area by multiplying the sum of critical heights measured on trees tallied in a horizontal point sample (HPS) by the HPS basal area factor. One of the barriers to practical application of CHS is the fact that trees near the field location of the point-sampling sample point have critical heights that occur...

  1. Community advocacy groups as a means to address the social environment of female sex workers: a case study in Andhra Pradesh, India.

    Science.gov (United States)

    Punyam, Swarup; Pullikalu, Renuka Somanatha; Mishra, Ram Manohar; Sandri, Prashanth; Mutupuru, Balakrishna Prasad; Kokku, Suresh Babu; Parimi, Prabhakar

    2012-10-01

    To examine the association between the presence of community advocacy groups (CAGs) and female sex workers' (FSWs) access to social entitlements and outcomes of police advocacy. Data were used from a cross-sectional survey conducted in 2010-2011 among 1986 FSWs and 104 NGO outreach workers from five districts of Andhra Pradesh. FSWs were recruited using a probability-based sampling from 104 primary sampling units (PSUs). A PSU is a geographical area covered by one outreach worker and is expected to have an active CAG as per community mobilisation efforts. The presence of active CAGs was defined as the presence of an active committee or advocacy group in the area (PSU). Outcome indicators included acquisition of different social entitlements and measures of police response as reported by FSWs. Multivariate linear and logistic regression analyses were used to examine the associations. Areas with active CAGs compared with their counterparts had a significantly higher mean number of FSWs linked to ration cards (12.8 vs 6.8; p<0.01), bank accounts (9.3 vs 5.9; p=0.05) and health insurance (13.1 vs 7.0; p=0.02). A significantly higher percentage of FSWs from areas with active CAGs as compared with others reported that the police treat them more fairly now than a year before (79.7% vs 70.3%; p<0.05) and the police explained the reasons for arrest when arrested the last time (95.7% vs 87%; p<0.05). FSWs from areas with active CAGs were more likely to access certain social entitlements and to receive a fair response from the police, highlighting the contributions of CAGs in community mobilisation.

  2. Quantitative portable gamma-spectroscopy sample analysis for non-standard sample geometries

    International Nuclear Information System (INIS)

    Ebara, S.B.

    1998-01-01

    Utilizing a portable spectroscopy system, a quantitative method for analysis of samples containing a mixture of fission and activation products in nonstandard geometries was developed. This method was not developed to replace other methods such as Monte Carlo or Discrete Ordinates but rather to offer an alternative rapid solution. The method can be used with various sample and shielding configurations where analysis on a laboratory based gamma-spectroscopy system is impractical. The portable gamma-spectroscopy method involves calibration of the detector and modeling of the sample and shielding to identify and quantify the radionuclides present in the sample. The method utilizes the intrinsic efficiency of the detector and the unattenuated gamma fluence rate at the detector surface per unit activity from the sample to calculate the nuclide activity and Minimum Detectable Activity (MDA). For a complex geometry, a computer code written for shielding applications (MICROSHIELD) is utilized to determine the unattenuated gamma fluence rate per unit activity at the detector surface. Lastly, the method is only applicable to nuclides which emit gamma-rays and cannot be used for pure beta or alpha emitters. In addition, if sample self absorption and shielding is significant, the attenuation will result in high MDA's for nuclides which solely emit low energy gamma-rays. The following presents the analysis technique and presents verification results using actual experimental data, rather than comparisons to other approximations such as Monte Carlo techniques, to demonstrate the accuracy of the method given a known geometry and source term. (author)

  3. Surface radiation survey and soil sampling of the 300-FF-1 operable unit, Hanford Site, southeastern Washington: A case study

    International Nuclear Information System (INIS)

    Teel, S.S.; Olsen, K.B.

    1990-10-01

    The methods used for conducting a radiological characterization of the soil surface for the Phase I Remedial Investigation of a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) site is presented via a case study. The study site is an operable unit (300-FF-1) located in and adjacent to the 300 Area of the US Department of Energy's Hanford Site in southeastern Washington State. The operable unit contains liquid and solid waste disposal facilities associated with nuclear fuels fabrication. Continuous surface radiation surveying and soil sampling of selected locations were conducted. Contamination was found in several locations within the operable unit including areas near the liquid and solid waste disposal facilities. Instruments used during surveying included portable beta/gamma (P-11) detectors, and the Ultrasonic Ranging and Data System using an NaI (Tl) detector. Laboratory analyses results indicate that above-background radiation levels were primarily due to the presence of uranium. Both types of field instruments used in the study were effective in detecting surface contamination from radionuclides; however, each had specific advantages. Guidelines are presented for the optimum use of these instruments when performing a radiological characterization of the soil surface. 4 refs., 3 figs., 3 tabs

  4. 30 CFR 71.201 - Sampling; general requirements.

    Science.gov (United States)

    2010-07-01

    ... MINES Sampling Procedures § 71.201 Sampling; general requirements. (a) Each operator shall take... required by this part with a sampling device approved by the Secretary and the Secretary of Health and Human Services under part 74 (Coal Mine Dust Personal Sampler Units) of this title. (b) Sampling devices...

  5. Automatic control unit for neutron transmission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Adib, M.; Abdel-Kawy, A.; Eid, Y.; Ashry, A.; Mostafa, M.; Hamouda, I. (Atomic Energy Establishment, Inshas (Egypt). Reactor and Neutron Physics Dept.)

    1981-01-01

    An automatic transistorized unit has been designed to control the neutron transmission measurements carried out using the time-of-flight spectrometer. The function of the automatic unit is to control the measurements of the neutron counting rate distribution transmitted through a sample at a selected channel group of the time analyzer for a certain preadjusted time period. At the end of this time, the unit removes the sample out of the neutron beam, selects a second equal channel group of the time analyzer and provides the measurement of the neutron counting rate distribution for the same time period as in the case with the sample on. Such a measuring cycle can be repeated as much as the experiment requires. At the end of these cycles the stored information can be immediately obtained through the analyzer read out unit. It is found that the time of removing the sample out of the neutron beam or returning it back does not exceed 20 seconds instead of the five minutes required in case of manual operation. The most important advantages of using such an automatic unit are saving about 20 percent of the reactor operating time avoidng unnecessary radiation exposure of the experimentalists.

  6. The Museum Library in the United States: A Sample

    Science.gov (United States)

    Hull, David; Fearnley, Henry D.

    1976-01-01

    A statistical survey was made of the general condition and problems of the museum library, using a questionnaire sent to a random sample of 856 historical, art, science, and other museum libraries. (Author)

  7. Triangulation based inclusion probabilities: a design-unbiased sampling approach

    OpenAIRE

    Fehrmann, Lutz; Gregoire, Timothy; Kleinn, Christoph

    2011-01-01

    A probabilistic sampling approach for design-unbiased estimation of area-related quantitative characteristics of spatially dispersed population units is proposed. The developed field protocol includes a fixed number of 3 units per sampling location and is based on partial triangulations over their natural neighbors to derive the individual inclusion probabilities. The performance of the proposed design is tested in comparison to fixed area sample plots in a simulation with two forest stands. ...

  8. Characteristics and Sampling Efficiency of Eight-Unit Linear Slot Impactor (EULSI)

    National Research Council Canada - National Science Library

    Kesavan, Jana S

    2006-01-01

    ...%, respectively. The l-mum PSL and Bg particles yielded a sampling efficiency of 2l% + 3 and 17% + 12 respectively. The standard deviation for the measured sampling efficiency of the Bg particles was higher...

  9. Standard guide for sampling radioactive tank waste

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This guide addresses techniques used to obtain grab samples from tanks containing high-level radioactive waste created during the reprocessing of spent nuclear fuels. Guidance on selecting appropriate sampling devices for waste covered by the Resource Conservation and Recovery Act (RCRA) is also provided by the United States Environmental Protection Agency (EPA) (1). Vapor sampling of the head-space is not included in this guide because it does not significantly affect slurry retrieval, pipeline transport, plugging, or mixing. 1.2 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Innovative solutions: sample financial management business plan: neurosurgical intensive care unit.

    Science.gov (United States)

    Villanueva-Baldonado, Analiza; Barrett-Sheridan, Shirley E

    2010-01-01

    This article describes one institution's intention to implement a financial management business plan for a neurosurgical intensive care unit in a level I trauma center. The financial objective of this proposed business plan includes a service increase in the patient population requiring critical care in a way that will help control costs.

  11. Transgender Population Size in the United States: a Meta-Regression of Population-Based Probability Samples

    Science.gov (United States)

    Sevelius, Jae M.

    2017-01-01

    Background. Transgender individuals have a gender identity that differs from the sex they were assigned at birth. The population size of transgender individuals in the United States is not well-known, in part because official records, including the US Census, do not include data on gender identity. Population surveys today more often collect transgender-inclusive gender-identity data, and secular trends in culture and the media have created a somewhat more favorable environment for transgender people. Objectives. To estimate the current population size of transgender individuals in the United States and evaluate any trend over time. Search methods. In June and July 2016, we searched PubMed, Cumulative Index to Nursing and Allied Health Literature, and Web of Science for national surveys, as well as “gray” literature, through an Internet search. We limited the search to 2006 through 2016. Selection criteria. We selected population-based surveys that used probability sampling and included self-reported transgender-identity data. Data collection and analysis. We used random-effects meta-analysis to pool eligible surveys and used meta-regression to address our hypothesis that the transgender population size estimate would increase over time. We used subsample and leave-one-out analysis to assess for bias. Main results. Our meta-regression model, based on 12 surveys covering 2007 to 2015, explained 62.5% of model heterogeneity, with a significant effect for each unit increase in survey year (F = 17.122; df = 1,10; b = 0.026%; P = .002). Extrapolating these results to 2016 suggested a current US population size of 390 adults per 100 000, or almost 1 million adults nationally. This estimate may be more indicative for younger adults, who represented more than 50% of the respondents in our analysis. Authors’ conclusions. Future national surveys are likely to observe higher numbers of transgender people. The large variety in questions used to ask

  12. Final LDRD report : development of sample preparation methods for ChIPMA-based imaging mass spectrometry of tissue samples.

    Energy Technology Data Exchange (ETDEWEB)

    Maharrey, Sean P.; Highley, Aaron M.; Behrens, Richard, Jr.; Wiese-Smith, Deneille

    2007-12-01

    The objective of this short-term LDRD project was to acquire the tools needed to use our chemical imaging precision mass analyzer (ChIPMA) instrument to analyze tissue samples. This effort was an outgrowth of discussions with oncologists on the need to find the cellular origin of signals in mass spectra of serum samples, which provide biomarkers for ovarian cancer. The ultimate goal would be to collect chemical images of biopsy samples allowing the chemical images of diseased and nondiseased sections of a sample to be compared. The equipment needed to prepare tissue samples have been acquired and built. This equipment includes an cyro-ultramicrotome for preparing thin sections of samples and a coating unit. The coating unit uses an electrospray system to deposit small droplets of a UV-photo absorbing compound on the surface of the tissue samples. Both units are operational. The tissue sample must be coated with the organic compound to enable matrix assisted laser desorption/ionization (MALDI) and matrix enhanced secondary ion mass spectrometry (ME-SIMS) measurements with the ChIPMA instrument Initial plans to test the sample preparation using human tissue samples required development of administrative procedures beyond the scope of this LDRD. Hence, it was decided to make two types of measurements: (1) Testing the spatial resolution of ME-SIMS by preparing a substrate coated with a mixture of an organic matrix and a bio standard and etching a defined pattern in the coating using a liquid metal ion beam, and (2) preparing and imaging C. elegans worms. Difficulties arose in sectioning the C. elegans for analysis and funds and time to overcome these difficulties were not available in this project. The facilities are now available for preparing biological samples for analysis with the ChIPMA instrument. Some further investment of time and resources in sample preparation should make this a useful tool for chemical imaging applications.

  13. 30 CFR 70.201 - Sampling; general requirements.

    Science.gov (United States)

    2010-07-01

    ...; general requirements. (a) Each operator shall take respirable dust samples of the concentration of respirable dust in the active workings of the mine as required by this part with a sampling device approved... Personal Sampler Units) of this title. (b) Sampling devices shall be worn or carried directly to and from...

  14. SamplingStrata: An R Package for the Optimization of Strati?ed Sampling

    Directory of Open Access Journals (Sweden)

    Giulio Barcaroli

    2014-11-01

    Full Text Available When designing a sampling survey, usually constraints are set on the desired precision levels regarding one or more target estimates (the Ys. If a sampling frame is available, containing auxiliary information related to each unit (the Xs, it is possible to adopt a stratified sample design. For any given strati?cation of the frame, in the multivariate case it is possible to solve the problem of the best allocation of units in strata, by minimizing a cost function sub ject to precision constraints (or, conversely, by maximizing the precision of the estimates under a given budget. The problem is to determine the best stratification in the frame, i.e., the one that ensures the overall minimal cost of the sample necessary to satisfy precision constraints. The Xs can be categorical or continuous; continuous ones can be transformed into categorical ones. The most detailed strati?cation is given by the Cartesian product of the Xs (the atomic strata. A way to determine the best stratification is to explore exhaustively the set of all possible partitions derivable by the set of atomic strata, evaluating each one by calculating the corresponding cost in terms of the sample required to satisfy precision constraints. This is una?ordable in practical situations, where the dimension of the space of the partitions can be very high. Another possible way is to explore the space of partitions with an algorithm that is particularly suitable in such situations: the genetic algorithm. The R package SamplingStrata, based on the use of a genetic algorithm, allows to determine the best strati?cation for a population frame, i.e., the one that ensures the minimum sample cost necessary to satisfy precision constraints, in a multivariate and multi-domain case.

  15. The Self-perception of Text-message Dependency Scale (STDS): Psychometric update based on a United States sample.

    Science.gov (United States)

    Liese, Bruce S; Benau, Erik M; Atchley, Paul; Reed, Derek; Becirevic, Amel; Kaplan, Brent

    2018-05-14

    Some have suggested that text messaging is an addictive behavior. However, this characterization is uncertain, partly due to lack of well-validated measures of text messaging attitudes and behaviors. One standard instrument for measuring text messaging attitudes and behaviors is the Self-perception of Text-message Dependency Scale (STDS), though the psychometric properties of this scale have only been examined with a sample of Japanese youth. The primary objective of this study was to evaluate the STDS in the United States to determine its utility as a measure of text messaging dependence. We were interested in examining the factor structure and determining the extent to which this scale would correlate with two important outcome measures: motor vehicle accidents (MVAs) and moving violations. We analyzed data from 468 adults (age 18-74; 274 women) recruited via Amazon's Mechanical Turk (mTurk) service. Participants completed the STDS and provided information about their driving-related incidents in the past year. First we performed a confirmatory factor analysis, which supported the instrument's original factor structure. Then we tested the relationship between scores on the STDS and two important variables, MVAs and moving violations. We found that the STDS significantly correlated with both MVAs and moving violations. The present study confirms that the STDS is a potentially useful instrument for studying texting dependence in the United States and with adults of all ages. The instrument may be particularly useful in predicting motor vehicle outcomes.

  16. Get on Board the Underground Railroad: A Sample Unit for Fifth-Grade History Students.

    Science.gov (United States)

    Ferguson, Phyllis M.; Young, Terrell A.

    1996-01-01

    Reviews the materials and procedures used in a fifth-grade history unit on the Underground Railroad. The unit integrated a variety of teaching methods and materials making extensive use of historical literature, K-W-L (what we Know, what we Want to find out, what we Learned) charts, and activities aimed at different learning styles. (MJP)

  17. A wall-free climate unit for acoustic levitators.

    Science.gov (United States)

    Schlegel, M C; Wenzel, K-J; Sarfraz, A; Panne, U; Emmerling, F

    2012-05-01

    Acoustic levitation represents the physical background of trapping a sample in a standing acoustic wave with no contact to the wave generating device. For the last three decades, sample holders based on this effect have been commonly used for contact free handling of samples coupled with a number of analytical techniques. In this study, a wall-free climate unit is presented, which allows the control of the environmental conditions of suspended samples. The insulation is based on a continuous cold/hot gas flow around the sample and thus does not require any additional isolation material. This provides a direct access to the levitated sample and circumvents any influence of the climate unit material to the running analyses.

  18. 7 CFR 42.143 - Operating Characteristic (OC) curves for on-line sampling and inspection.

    Science.gov (United States)

    2010-01-01

    ...=Number of sample units in a subgroup. T=Subgroup tolerance.L=Acceptance limit.S=Starting value. EC02SE91... ng=Number of sample units in a subgroup. T=Subgroup tolerance. L=Acceptance limit. S=Starting value... of sample units in a subgroup. T=Subgroup tolerance. L=Acceptance limit. S=Starting value. EC02SE91...

  19. 7 CFR 201.43 - Size of sample.

    Science.gov (United States)

    2010-01-01

    ... units. Coated seed for germination test only shall consist of at least 1,000 seed units. [10 FR 9950... of samples of agricultural seed, vegetable seed and screenings to be submitted for analysis, test, or..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) FEDERAL SEED ACT FEDERAL SEED ACT...

  20. Gendered motivational processes affecting high school mathematics participation, educational aspirations, and career plans: a comparison of samples from Australia, Canada, and the United States.

    Science.gov (United States)

    Watt, Helen M G; Shapka, Jennifer D; Morris, Zoe A; Durik, Amanda M; Keating, Daniel P; Eccles, Jacquelynne S

    2012-11-01

    In this international, longitudinal study, we explored gender differences in, and gendered relationships among, math-related motivations emphasized in the Eccles (Parsons) et al. (1983) expectancy-value framework, high school math participation, educational aspirations, and career plans. Participants were from Australia, Canada, and the United States (Ns = 358, 471, 418, respectively) in Grades 9/10 at Time 1 and Grades 11/12 at Time 2. The 3 samples came from suburban middle to upper-middle socioeconomic backgrounds, primarily of Anglo-European descent. Multivariate analyses of variance revealed stereotypic gender differences in educational and occupational outcomes only among the Australian sample. Multigroup structural equation models identified latent mean differences where male adolescents held higher intrinsic value for math in the Australian sample and higher ability/success expectancy in both North American samples. Ability/success expectancy was a key predictor in the North American samples, in contrast to intrinsic value in the Australian sample. Attainment/utility ("importance") values were more important for female adolescents' career choices, except in the Australian sample. Findings are interpreted in relation to gender socialization practices, degree and type of early choice, and specialization across settings. Implications are discussed for long-term math engagement and career selection for female and male adolescents. (PsycINFO Database Record (c) 2012 APA, all rights reserved).

  1. Sample preparation composite and replicate strategy for assay of solid oral drug products.

    Science.gov (United States)

    Harrington, Brent; Nickerson, Beverly; Guo, Michele Xuemei; Barber, Marc; Giamalva, David; Lee, Carlos; Scrivens, Garry

    2014-12-16

    In pharmaceutical analysis, the results of drug product assay testing are used to make decisions regarding the quality, efficacy, and stability of the drug product. In order to make sound risk-based decisions concerning drug product potency, an understanding of the uncertainty of the reportable assay value is required. Utilizing the most restrictive criteria in current regulatory documentation, a maximum variability attributed to method repeatability is defined for a drug product potency assay. A sampling strategy that reduces the repeatability component of the assay variability below this predefined maximum is demonstrated. The sampling strategy consists of determining the number of dosage units (k) to be prepared in a composite sample of which there may be a number of equivalent replicate (r) sample preparations. The variability, as measured by the standard error (SE), of a potency assay consists of several sources such as sample preparation and dosage unit variability. A sampling scheme that increases the number of sample preparations (r) and/or number of dosage units (k) per sample preparation will reduce the assay variability and thus decrease the uncertainty around decisions made concerning the potency of the drug product. A maximum allowable repeatability component of the standard error (SE) for the potency assay is derived using material in current regulatory documents. A table of solutions for the number of dosage units per sample preparation (r) and number of replicate sample preparations (k) is presented for any ratio of sample preparation and dosage unit variability.

  2. Summary evaluation of Yucca Mountain surface transects with implications for downhole sampling. Yucca Mountain Site Characterization Project

    International Nuclear Information System (INIS)

    Mckenna, S.A.; Rautman, C.A.

    1995-06-01

    The results of previously completed vertical outcrop sampling transacts are summarized with respect to planning downhole sampling. The summary includes statistical descriptions and descriptions of the spatial variability of the sampled parameters. Descriptions are made on each individual transect, each thermal/mechanical unit and each previously defined geohydrologic unit. Correlations between parameters indicate that saturated hydraulic conductivity is not globally correlated to porosity. The correlation between porosity and saturated hydraulic conductivity is both spatially and lithologically dependent. Currently, there are not enough saturated hydraulic conductivity and sorptivity data to define relationships between these properties and porosity on a unit by unit basis. Also, the Prow Pass member of the Crater Flat Tuff and stratigraphically lower units have gone essentially unsampled in these outcrop transacts. The vertical correlation length for hydrologic properties is not constant across the area of the transacts. The average sample spacing within the transacts ranges from 1.25 to 2.1 meters. It appears that, with the exception of the Topopah Spring member units, a comparable sample spacing will give adequate results in the downhole sampling campaign even with the nonstationarity of the vertical correlation. The properties within the thermal/mechanical units and geohydrologic units of the Topopah Spring member appear to have a spatial correlation range less than or equal to the current sample spacing within these units. For the downhole sampling, a sample spacing of less than 1.0 meters may be necessary within these units

  3. Shuttle Kit Freezer Refrigeration Unit Conceptual Design

    Science.gov (United States)

    Copeland, R. J.

    1975-01-01

    The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

  4. Operability test procedure for PFP wastewater sampling facility

    International Nuclear Information System (INIS)

    Hirzel, D.R.

    1995-01-01

    Document provides instructions for performing the Operability Test of the 225-WC Wastewater Sampling Station which monitors the discharge to the Treated Effluent Disposal Facility from the Plutonium Finishing Plant. This Operability Test Procedure (OTP) has been prepared to verify correct configuration and performance of the PFP Wastewater sampling system installed in Building 225-WC located outside the perimeter fence southeast of the Plutonium Finishing Plant (PFP). The objective of this test is to ensure the equipment in the sampling facility operates in a safe and reliable manner. The sampler consists of two Manning Model S-5000 units which are rate controlled by the Milltronics Ultrasonic flowmeter at manhole No.C4 and from a pH measuring system with the sensor in the stream adjacent to the sample point. The intent of the dual sampling system is to utilize one unit to sample continuously at a rate proportional to the wastewater flow rate so that the aggregate tests are related to the overall flow and thereby eliminate isolated analyses. The second unit will only operate during a high or low pH excursion of the stream (hence the need for a pH control). The major items in this OTP include testing of the Manning Sampler System and associated equipment including the pH measuring and control system, the conductivity monitor, and the flow meter

  5. WIPP Sampling and Analysis Plan for Solid Waste Management Units and Areas of Concern

    International Nuclear Information System (INIS)

    2000-01-01

    This Sampling and Analysis Plan (SAP) has been prepared to fulfill requirements of Module VII, Section VII.M.2 and Table VII.1, requirement 4 of the Waste Isolation Pilot Plant (WIPP) Hazardous Waste Permit, NM4890139088-TSDF (the Permit); (NMED [New Mexico Environment Department], 1999a). This SAP describes the approach for investigation of the Solid Waste Management Units (SWMU) and Areas of Concern (AOC) specified in the Permit. This SAP addresses the current Permit requirements for a RCRA Facility Investigation(RFI) investigation of SWMUs and AOCs. It uses the results of previous investigations performed at WIPP and expands the investigations as required by the Permit. As an alternative to the RFI specified in Module VII of the Permit, current NMED guidance identifies an Accelerated Corrective Action Approach (ACAA) that may be used for any SWMU or AOC (NMED, 1998). This accelerated approach is used to replace the standard RFI work plan and report sequence with a more flexible decision-making approach. The ACAA process allows a facility to exit the schedule of compliance contained in the facility's Hazardous and Solid Waste Amendments (HSWA) permit module and proceed on an accelerated time frame. Thus, the ACAA process can beentered either before or after a RFI work plan. According to NMED's guidance, a facility can prepare a RFI work plan or SAP for any SWMU or AOC (NMED, 1998).

  6. Legionella spp. in dental unit waterlines.

    Science.gov (United States)

    Sedlata Juraskova, E; Sedlackova, H; Janska, J; Holy, O; Lalova, I; Matouskova, I

    2017-01-01

    To determine the current presence of Legionella spp. in the output water of dental unit waterlines (DUWLs) and examine its mitigation by disinfection at the Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc. The first stage of our survey involved collecting samples of DUWL output water from 50 dental chair units (DCUs), and 2 samples of the incoming potable water. In October 2015, a one-time disinfection (1 % Stabimed) of DUWLs was conducted. This was followed by collecting 10 control samples (survey stage 2). From the total of 50 samples (survey stage 1), 18 samples (36.0 %) tested positive for Legionella spp. Following the disinfection, nine of the ten samples no longer showed any presence of Legionella. Based on culture results, the one-time disinfection (1 % Stabimed) was effective. We are unable to comment on the duration of positive effect of disinfection on the occurrence of Legionella spp. in the outlet water. It was a one-time survey (Tab. 2, Ref. 32).

  7. 19 CFR 151.70 - Method of sampling by Customs.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Method of sampling by Customs. 151.70 Section 151... THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.70 Method of sampling by Customs. A general sample shall be taken from each sampling unit, unless it is not...

  8. Impact of Systematic Sampling on Causality in the presence of Unit Roots

    OpenAIRE

    Rajaguru GULASEKARAN

    2002-01-01

    Quite contrary to the stationary case where systematic sampling preserves the direction of Granger causality, this paper shows that systematic sampling of integrated series may induce spurious causality, even if they are used in differenced form.

  9. Samples in applied psychology: over a decade of research in review.

    Science.gov (United States)

    Shen, Winny; Kiger, Thomas B; Davies, Stacy E; Rasch, Rena L; Simon, Kara M; Ones, Deniz S

    2011-09-01

    This study examines sample characteristics of articles published in Journal of Applied Psychology (JAP) from 1995 to 2008. At the individual level, the overall median sample size over the period examined was approximately 173, which is generally adequate for detecting the average magnitude of effects of primary interest to researchers who publish in JAP. Samples using higher units of analyses (e.g., teams, departments/work units, and organizations) had lower median sample sizes (Mdn ≈ 65), yet were arguably robust given typical multilevel design choices of JAP authors despite the practical constraints of collecting data at higher units of analysis. A substantial proportion of studies used student samples (~40%); surprisingly, median sample sizes for student samples were smaller than working adult samples. Samples were more commonly occupationally homogeneous (~70%) than occupationally heterogeneous. U.S. and English-speaking participants made up the vast majority of samples, whereas Middle Eastern, African, and Latin American samples were largely unrepresented. On the basis of study results, recommendations are provided for authors, editors, and readers, which converge on 3 themes: (a) appropriateness and match between sample characteristics and research questions, (b) careful consideration of statistical power, and (c) the increased popularity of quantitative synthesis. Implications are discussed in terms of theory building, generalizability of research findings, and statistical power to detect effects. PsycINFO Database Record (c) 2011 APA, all rights reserved

  10. Two sampling techniques for game meat

    Directory of Open Access Journals (Sweden)

    Maretha van der Merwe

    2013-03-01

    Full Text Available A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g and square centimetres (cm2 for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12 that statistically proved the two measuring units correlated. The two sampling techniques were conducted on the same game carcasses (n = 13 and analyses performed for aerobic plate count (APC, Escherichia coli and Staphylococcus aureus, for both techniques. A more representative result was obtained by swabbing and no damage was caused to the carcass. Conversely, the excision technique yielded fewer organisms and caused minor damage to the carcass. The recovery ratio from the sampling technique improved 5.4 times for APC, 108.0 times for E. coli and 3.4 times for S. aureus over the results obtained from the excision technique. It was concluded that the sampling methods of excision and swabbing can be used to obtain bacterial profiles from both export and local carcasses and could be used to indicate whether game carcasses intended for the local market are possibly on par with game carcasses intended for the export market and therefore safe for human consumption.

  11. Two sampling techniques for game meat.

    Science.gov (United States)

    van der Merwe, Maretha; Jooste, Piet J; Hoffman, Louw C; Calitz, Frikkie J

    2013-03-20

    A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g) and square centimetres (cm2) for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12) that statistically proved the two measuring units correlated. The two sampling techniques were conducted on the same game carcasses (n = 13) and analyses performed for aerobic plate count (APC), Escherichia coli and Staphylococcus aureus, for both techniques. A more representative result was obtained by swabbing and no damage was caused to the carcass. Conversely, the excision technique yielded fewer organisms and caused minor damage to the carcass. The recovery ratio from the sampling technique improved 5.4 times for APC, 108.0 times for E. coli and 3.4 times for S. aureus over the results obtained from the excision technique. It was concluded that the sampling methods of excision and swabbing can be used to obtain bacterial profiles from both export and local carcasses and could be used to indicate whether game carcasses intended for the local market are possibly on par with game carcasses intended for the export market and therefore safe for human consumption.

  12. Sampling and analysis plan for the site characterization of the waste area Grouping 1 groundwater operable unit at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    1994-11-01

    Waste Area Grouping (WAG) 1 at Oak Ridge National Laboratory (ORNL) includes all of the former ORNL radioisotope research, production, and maintenance facilities; former waste management areas; and some former administrative buildings. Site operations have contaminated groundwater, principally with radiological contamination. An extensive network of underground pipelines and utilities have contributed to the dispersal of contaminants to a known extent. In addition, karst geology, numerous spills, and pipeline leaks, together with the long and varied history of activities at specific facilities at ORNL, complicate contaminant migration-pathway analysis and source identification. To evaluate the extent of contamination, site characterization activity will include semiannual and annual groundwater sampling, as well as monthly water level measurements (both manual and continuous) at WAG 1. This sampling and analysis plan provides the methods and procedures to conduct site characterization for the Phase 1 Remedial Investigation of the WAG 1 Groundwater Operable Unit

  13. Statistical issues in reporting quality data: small samples and casemix variation.

    Science.gov (United States)

    Zaslavsky, A M

    2001-12-01

    To present two key statistical issues that arise in analysis and reporting of quality data. Casemix variation is relevant to quality reporting when the units being measured have differing distributions of patient characteristics that also affect the quality outcome. When this is the case, adjustment using stratification or regression may be appropriate. Such adjustments may be controversial when the patient characteristic does not have an obvious relationship to the outcome. Stratified reporting poses problems for sample size and reporting format, but may be useful when casemix effects vary across units. Although there are no absolute standards of reliability, high reliabilities (interunit F > or = 10 or reliability > or = 0.9) are desirable for distinguishing above- and below-average units. When small or unequal sample sizes complicate reporting, precision may be improved using indirect estimation techniques that incorporate auxiliary information, and 'shrinkage' estimation can help to summarize the strength of evidence about units with small samples. With broader understanding of casemix adjustment and methods for analyzing small samples, quality data can be analysed and reported more accurately.

  14. Controlling a sample changer using the integrated counting system

    International Nuclear Information System (INIS)

    Deacon, S.; Stevens, M.P.

    1985-06-01

    Control of the Sample Changer from a counting system can be achieved by using a Scaler Timer type 6255 and Sample Changer Control Interface type 6263. The interface used, however, has quite complex circuitry. The application therefore lends itself to the use of another 6000 Series module the Integrated Counting System (ICS). Using this unit control is carried out through a control program written in BASIC for the Commodore PET (or any other device with an IEEE-488 interface). The ICS then controls the sample changer through an interface unit which is relatively simple. A brief description of how ICS controls the sample changer is given. The control program is then described, firstly the running options are given, followed by a program description listing and flowchart. (author)

  15. Controlling a sample changer using the integrated counting system

    Energy Technology Data Exchange (ETDEWEB)

    Deacon, S; Stevens, M P

    1985-06-01

    Control of the Sample Changer from a counting system can be achieved by using a Scaler Timer type 6255 and Sample Changer Control Interface type 6263. The interface used, however, has quite complex circuitry. The application therefore lends itself to the use of another 6000 Series module-the Integrated Counting System (ICS). Using this unit control is carried out through a control program written in BASIC for the Commodore PET (or any other device with an IEEE-488 interface). The ICS then controls the sample changer through an interface unit which is relatively simple. A brief description of how ICS controls the sample changer is given. The control program is then described; first the running options are given, followed by a program description listing and flowchart.

  16. WIPP Sampling and Analysis Plan for Solid Waste Management Units and Areas of Concern

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2000-05-23

    This Sampling and Analysis Plan (SAP) has been prepared to fulfill requirements of Module VII, Section VII.M.2 and Table VII.1, requirement 4 of the Waste Isolation Pilot Plant (WIPP) Hazardous Waste Permit, NM4890139088-TSDF (the Permit); (NMED [New Mexico Environment Department], 1999a). This SAP describes the approach for investigation of the Solid Waste Management Units (SWMU) and Areas of Concern (AOC) specified in the Permit. This SAP addresses the current Permit requirements for a RCRA Facility Investigation(RFI) investigation of SWMUs and AOCs. It uses the results of previous investigations performed at WIPP and expands the investigations as required by the Permit. As an alternative to the RFI specified in Module VII of the Permit, current NMED guidance identifies an Accelerated Corrective Action Approach (ACAA) that may be used for any SWMU or AOC (NMED, 1998). This accelerated approach is used to replace the standard RFI work plan and report sequence with a more flexible decision-making approach. The ACAA process allows a facility to exit the schedule of compliance contained in the facility's Hazardous and Solid Waste Amendments (HSWA) permit module and proceed on an accelerated time frame. Thus, the ACAA process can beentered either before or after a RFI work plan. According to NMED's guidance, a facility can prepare a RFI work plan or SAP for any SWMU or AOC (NMED, 1998).

  17. Associations among unit leadership and unit climates for implementation in acute care: a cross-sectional study.

    Science.gov (United States)

    Shuman, Clayton J; Liu, Xuefeng; Aebersold, Michelle L; Tschannen, Dana; Banaszak-Holl, Jane; Titler, Marita G

    2018-04-25

    Nurse managers have a pivotal role in fostering unit climates supportive of implementing evidence-based practices (EBPs) in care delivery. EBP leadership behaviors and competencies of nurse managers and their impact on practice climates are widely overlooked in implementation science. The purpose of this study was to examine the contributions of nurse manager EBP leadership behaviors and nurse manager EBP competencies in explaining unit climates for EBP implementation in adult medical-surgical units. A multi-site, multi-unit cross-sectional research design was used to recruit the sample of 24 nurse managers and 553 randomly selected staff nurses from 24 adult medical-surgical units from 7 acute care hospitals in the Northeast and Midwestern USA. Staff nurse perceptions of nurse manager EBP leadership behaviors and unit climates for EBP implementation were measured using the Implementation Leadership Scale and Implementation Climate Scale, respectively. EBP competencies of nurse managers were measured using the Nurse Manager EBP Competency Scale. Participants were emailed a link to an electronic questionnaire and asked to respond within 1 month. The contributions of nurse manager EBP leadership behaviors and competencies in explaining unit climates for EBP implementation were estimated using mixed-effects models controlling for nurse education and years of experience on current unit and accounting for the variability across hospitals and units. Significance level was set at α < .05. Two hundred sixty-four staff nurses and 22 nurse managers were included in the final sample, representing 22 units in 7 hospitals. Nurse manager EBP leadership behaviors (p < .001) and EBP competency (p = .008) explained 52.4% of marginal variance in unit climate for EBP implementation. Leadership behaviors uniquely explained 45.2% variance. The variance accounted for by the random intercepts for hospitals and units (p < .001) and years of nursing experience in current unit

  18. A Comparison of Hazard Prediction and Assessment Capability (HPAC) Software Dose-Rate Contour Plots to a Sample of Local Fallout Data From Test Detonations in the Continental United States, 1945 - 1962

    National Research Council Canada - National Science Library

    Chancellor, Richard W

    2005-01-01

    A comparison of Hazard Prediction and Assessment Capability (HPAC) software dose-rate contour plots to a sample of local nuclear fallout data from test detonations in the continental United States, 1945 - 1962, is performed...

  19. Gamma: A C++ Sound Synthesis Library Further Abstracting the Unit Generator

    DEFF Research Database (Denmark)

    Putnam, Lance Jonathan

    2014-01-01

    Gamma is a C++ library for sound synthesis that was created to address some of the limitations of existing sound synthesis libraries. The first limitation is that unit generators cannot easily be organized into separate sampling domains. This makes it difficult to use unit generators with different...... sample rates and in other domains, namely the frequency domain. The second limitation is that certain internal unit generator algorithms, such as interpolation, cannot be customized. This tends to lead to closed architectures consisting of multiple unit generators with only slight algorithmic differences...

  20. Radon measurement in Malaysia water samples

    International Nuclear Information System (INIS)

    Ibrahim, A.B.; Rosli Mahat; Yusof Md Amin

    1995-01-01

    This paper reported the results of the measurement of radon in local water. The water samples collected were rainwater, river water, seawater, well water or ground water at area of State of Selangor and Kuala Lumpur. The samples were collected in scintillation cell ZnS(Ag) through Radon Degassing Unit RDU 200. Alpha activity was counted with scintillation counters RD 200 at energy 5.5 MeV. (author)

  1. A profile of acute care in an aging America: snowball sample identification and characterization of United States geriatric emergency departments in 2013.

    Science.gov (United States)

    Hogan, Teresita M; Olade, Tolulope Oyeyemi; Carpenter, Christopher R

    2014-03-01

    The aging of America poses a challenge to emergency departments (EDs). Studies show that elderly patients have poor outcomes despite increased testing, prolonged periods of observation, and higher admission rates. In response, emergency medicine (EM) leaders have implemented strategies for improved ED elder care, enhancing expertise, equipment, policies, and protocols. One example is the development of geriatric EDs gaining in popularity nationwide. To the authors' knowledge, this is the first research to systematically identify and qualitatively characterize the existence, locations, and features of geriatric EDs across the United States. The primary objective was to determine the number, distribution, and characteristics of geriatric EDs in the United States in 2013. This was a survey with potential respondents identified via a snowball sampling of known geriatric EDs, EM professional organizations' geriatric interest groups, and a structured search of the Internet using multiple search engines. Sites were contacted by telephone, and those confirming geriatric EDs presence received the survey via e-mail. Category questions included date of opening, location, volumes, staffing, physical plant changes, screening tools, policies, and protocols. Categories were reported based on general interest to those seeking to understand components of a geriatric ED. Thirty-six hospitals confirmed geriatric ED existence and received surveys. Thirty (83%) responded to the survey and confirmed presence or plans for geriatric EDs: 24 (80%) had existing geriatric EDs, and six (20%) were planning to open geriatric EDs by 2014. The majority of geriatric EDs are located in the Midwest (46%) and Northeast (30%) regions of the United States. Eighty percent serve from 5,000 to 20,000 elder patients annually. Seventy percent of geriatric EDs are attached to the main ED, and 66% have from one to 10 geriatric beds. Physical plant changes include modifications to beds (96%), lighting (90

  2. PFP Wastewater Sampling Facility

    International Nuclear Information System (INIS)

    Hirzel, D.R.

    1995-01-01

    This test report documents the results obtained while conducting operational testing of the sampling equipment in the 225-WC building, the PFP Wastewater Sampling Facility. The Wastewater Sampling Facility houses equipment to sample and monitor the PFP's liquid effluents before discharging the stream to the 200 Area Treated Effluent Disposal Facility (TEDF). The majority of the streams are not radioactive and discharges from the PFP Heating, Ventilation, and Air Conditioning (HVAC). The streams that might be contaminated are processed through the Low Level Waste Treatment Facility (LLWTF) before discharging to TEDF. The sampling equipment consists of two flow-proportional composite samplers, an ultrasonic flowmeter, pH and conductivity monitors, chart recorder, and associated relays and current isolators to interconnect the equipment to allow proper operation. Data signals from the monitors are received in the 234-5Z Shift Office which contains a chart recorder and alarm annunciator panel. The data signals are also duplicated and sent to the TEDF control room through the Local Control Unit (LCU). Performing the OTP has verified the operability of the PFP wastewater sampling system. This Operability Test Report documents the acceptance of the sampling system for use

  3. Variability of pesticide residues in eggplant units collected from a field trial and marketplaces in Greece.

    Science.gov (United States)

    Prodhan, Mohammad Dalower Hossain; Papadakis, Emmanouil-Nikolaos; Papadopoulou-Mourkidou, Euphemia

    2018-04-01

    Variability of pesticide residues among food items is very important when assessing the risks and food safety for the consumers. Therefore, the present study was undertaken to estimate the unit-to-unit residue variability factors for eggplant. In total, 120 samples from a trial field and 142 samples from different marketplaces in Thessaloniki, Greece, were collected to estimate the variability of pesticide residues in eggplant units. They were extracted by the QuEChERS method and the residues were determined by LC-MS/MS. For the field samples, the unit-to-unit variability factors (VFs) obtained for cypermethrin and deltamethrin residues were 2.54 and 2.51, respectively. The mean residue levels of both pesticides were higher in the composite samples than in the individual samples. The average VFs for the marketplace samples was 3.89. The eggplant units exposed to pesticides were higher in residues than the non-exposed units. The variability factors obtained in the marketplace samples were higher than those in the samples collected from the field trial. A default VF value of 3 for field trials is appropriate for use when assessing the acute dietary intake but a VF for the marketplace samples should be reconsidered with a larger data. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  4. Validation of a High Sampling Rate Inertial Measurement Unit for Acceleration During Running.

    Science.gov (United States)

    Provot, Thomas; Chiementin, Xavier; Oudin, Emeric; Bolaers, Fabrice; Murer, Sébastien

    2017-08-25

    The musculo-skeletal response of athletes to various activities during training exercises has become a critical issue in order to optimize their performance and minimize injuries. However, dynamic and kinematic measures of an athlete's activity are generally limited by constraints in data collection and technology. Thus, the choice of reliable and accurate sensors is crucial for gathering data in indoor and outdoor conditions. The aim of this study is to validate the use of the accelerometer of a high sampling rate ( 1344 Hz ) Inertial Measurement Unit (IMU) in the frame of running activities. To this end, two validation protocols are imposed: a classical one on a shaker, followed by another one during running, the IMU being attached to a test subject. For each protocol, the response of the IMU Accelerometer (IMUA) is compared to a calibrated industrial accelerometer, considered as the gold standard for dynamic and kinematic data collection. The repeatability, impact of signal frequency and amplitude (on shaker) as well as the influence of speed (while running) are investigated. Results reveal that the IMUA exhibits good repeatability. Coefficient of Variation CV is 1 % 8.58 ± 0.06 m / s 2 on the shaker and 3 % 26.65 ± 0.69 m / s 2 while running. However, the shaker test shows that the IMUA is affected by the signal frequency (error exceeds 10 % beyond 80 Hz ), an observation confirmed by the running test. Nevertheless, the IMUA provides a reliable measure in the range 0-100 Hz, i.e., the most relevant part in the energy spectrum over the range 0-150 Hz during running. In our view, these findings emphasize the validity of IMUs for the measurement of acceleration during running.

  5. Coordination of Conditional Poisson Samples

    Directory of Open Access Journals (Sweden)

    Grafström Anton

    2015-12-01

    Full Text Available Sample coordination seeks to maximize or to minimize the overlap of two or more samples. The former is known as positive coordination, and the latter as negative coordination. Positive coordination is mainly used for estimation purposes and to reduce data collection costs. Negative coordination is mainly performed to diminish the response burden of the sampled units. Poisson sampling design with permanent random numbers provides an optimum coordination degree of two or more samples. The size of a Poisson sample is, however, random. Conditional Poisson (CP sampling is a modification of the classical Poisson sampling that produces a fixed-size πps sample. We introduce two methods to coordinate Conditional Poisson samples over time or simultaneously. The first one uses permanent random numbers and the list-sequential implementation of CP sampling. The second method uses a CP sample in the first selection and provides an approximate one in the second selection because the prescribed inclusion probabilities are not respected exactly. The methods are evaluated using the size of the expected sample overlap, and are compared with their competitors using Monte Carlo simulation. The new methods provide a good coordination degree of two samples, close to the performance of Poisson sampling with permanent random numbers.

  6. 9 CFR 113.3 - Sampling of biological products.

    Science.gov (United States)

    2010-01-01

    ... into the United States as prescribed in this section. Additional samples may be purchased in the open market by a Animal and Plant Health Inspection Service representative. (a) Either an employee of the... operation. Bulk containers of completed product may be sampled when authorized by the Administrator. (iii...

  7. A Novel Analysis Method for Paired-Sample Microbial Ecology Experiments.

    Science.gov (United States)

    Olesen, Scott W; Vora, Suhani; Techtmann, Stephen M; Fortney, Julian L; Bastidas-Oyanedel, Juan R; Rodríguez, Jorge; Hazen, Terry C; Alm, Eric J

    2016-01-01

    Many microbial ecology experiments use sequencing data to measure a community's response to an experimental treatment. In a common experimental design, two units, one control and one experimental, are sampled before and after the treatment is applied to the experimental unit. The four resulting samples contain information about the dynamics of organisms that respond to the treatment, but there are no analytical methods designed to extract exactly this type of information from this configuration of samples. Here we present an analytical method specifically designed to visualize and generate hypotheses about microbial community dynamics in experiments that have paired samples and few or no replicates. The method is based on the Poisson lognormal distribution, long studied in macroecology, which we found accurately models the abundance distribution of taxa counts from 16S rRNA surveys. To demonstrate the method's validity and potential, we analyzed an experiment that measured the effect of crude oil on ocean microbial communities in microcosm. Our method identified known oil degraders as well as two clades, Maricurvus and Rhodobacteraceae, that responded to amendment with oil but do not include known oil degraders. Our approach is sensitive to organisms that increased in abundance only in the experimental unit but less sensitive to organisms that increased in both control and experimental units, thus mitigating the role of "bottle effects".

  8. Jazz Listening Activities: Children's Literature and Authentic Music Samples.

    Science.gov (United States)

    McDonald, Nan L.; Fisher, Douglas; Helzer, Rick

    2002-01-01

    Describes a unit that is appropriate for upper elementary and middle school students that focuses on jazz music using biographies about jazz musicians. Discusses the five sections of the unit. Includes a list of "Suggested Jazz Listening Samples," jazz videos, and a bibliography of resources related to jazz music. (CMK)

  9. Antifungal efficacy of hydrogen peroxide in dental unit waterline disinfection.

    Science.gov (United States)

    Szymańska, Jolanta

    2006-01-01

    The concentration and composition of fungal flora in dental unit waterlines (DUWL) were evaluated. For this purpose, water samples from unit reservoirs and high-speed handpieces, and biofilm samples from the waterline walls from units were collected. Subsequently, analogous samples from DUWL were taken before and after disinfection using agent containing hydrogen peroxide. In the examined samples, the yeast-like fungi Candida albicans and Candida curvata were found. The following species of mould were also identified: Aspergillus amstelodami, Aspergillus fumigatus, Aspergillus glaucus group, Aspergillus (=Eurotium herbariorum) repens, Citromyces spp., Geotrichum candidum, Penicillium (glabrum) frequentans, Penicillium pusillum, Penicillium turolense and Sclerotium sclerotiorum (Sclerotinia sclerotiorum). Before disinfection, Candida curvata and Candida albicans constituted the greatest proportion of the total fungi in the reservoirs water; in the water of handpieces--Candida albicans and Aspergillus glaucus group; and in the biofilm samples--Aspergillus glaucus group and Candida albicans. After disinfection, in all 3 kinds of samples, Candida albicans prevailed, constituting from 31.2-85.7 % of the total fungi. The application of agent containing hydrogen peroxide caused a significant decrease both in the number of total fungi and individual fungal species, which confirms the product effectiveness in fungal decontamination of DUWL.

  10. A Psychometric Investigation of the Academic Motivation Scale Using a United States Sample.

    Science.gov (United States)

    Cokley, Kevin O.; Bernard, Naijean; Cunningham, Dana; Motoike, Janice

    2001-01-01

    Examines the factor structure of the Academic Motivation Scale with a United States student population. There was some support for a 7-factor structure. Evidence of construct validity examining the relationship with academic self concept and academic achievement is mixed. Discusses ethnic and gender differences in motivation. (Contains 37…

  11. Geochemical surveys in the United States in relation to health

    Energy Technology Data Exchange (ETDEWEB)

    Tourtelot, H A

    1979-12-11

    Geochemical surveys in relation to health may be classified as having one, two or three dimensions. One-dimensional surveys examine relations between concentrations of elements such as Pb in soils and other media and burdens of the same elements in humans, at a given time. The spatial distributions of element concentrations are not investigated. The primary objective of two-dimensional surveys is to map the distributions of element concentrations, commonly according to stratified random sampling designs based on either conceptual landscape units or artificial sampling strata, but systematic sampling intervals have also been used. Political units have defined sample areas that coincide with the units used to accumulate epidemiological data. Element concentrations affected by point sources have also been mapped. Background values, location of natural or technological anomalies and the geographic scale of variation for several elements often are determined. Three-dimensional surveys result when two-dimensional surveys are repeated to detect environmental changes.

  12. SI units in biomedical dosimetry

    International Nuclear Information System (INIS)

    Liden, K.

    1975-01-01

    The International commission on radiation units and measurements (ICRU), during the period from 1953 to 1962 presented its definitions of the quantities absorbed dose, exposure, activity, and dose equivalent and the corresponding special units the rad, the roentgen, the curie, and the rem. At the same time an international practical system of units was developed, Le Systeme International d'Unites (SI). It was adopted by the 11th Conference Generale des Poids et Mesures (CGPM) in 1960 and is now officially introduced in almost all countries. The general implementation of the SI means difficulties for the future use of the special radiation units, because the numerical factors involved prevent their adoption as SI units. In view of this, and after having sampled the opinion in the radiological field, the ICRU prepared a Statement on Units in July, 1974 which was forwarded to the Comite International des Poids et Mesures (CIPM) and its Comite Consultatif des Unites (CCU) for consideration. As a result of this statement the CIPM has now proposed, that the 15rh CGPM adopt special names for two SI units, namely the becquerel, symbol Bq, for the unit of activity of radionuclides equal to the reciprocal second, s 1- , and the gray, symbol Gy, for the unit of absorbed dose equal to the joule per kilogram, J/kg. The 15th CGPM will consider this matter in May, 1975. (author)

  13. Age, sex, and racial differences in harsh physical punishment: results from a nationally representative United States sample.

    Science.gov (United States)

    Taillieu, Tamara L; Afifi, Tracie O; Mota, Natalie; Keyes, Katherine M; Sareen, Jitender

    2014-12-01

    The purpose of this research was to examine age, sex, and racial differences in the prevalence of harsh physical punishment in childhood in a nationally representative sample of the United States. Data were from the National Epidemiologic Survey on Alcohol and Related Conditions (NESARC) collected in 2004 and 2005 (n=34,653). Logistic regression analyses were conducted to examine age, sex, and racial differences in the prevalence of harsh physical punishment. Results suggest that the prevalence of harsh physical punishment has been decreasing among more recently born age groups; however, there appear to be sex and racial differences in this trend over time. The magnitude of the decrease appears to be stronger for males than for females. By race, the decrease in harsh physical punishment over time is only apparent among Whites; Black participants demonstrate little change over time, and harsh physical punishment seems to be increasing over time among Hispanics. Prevention and intervention efforts that educate about the links of physical punishment to negative outcomes and alternative non-physical discipline strategies may be particularly useful in reducing the prevalence of harsh physical punishment over time. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. The effects of unit morale and interpersonal relations on conflict in the nursing unit.

    Science.gov (United States)

    Cox, K B

    2001-07-01

    Health care organizations face major changes, and these changes are likely to increase conflict in organizations. Although numerous studies have focused on conflict management, few have considered causes and effect of conflict in nursing units. The investigation tested a structural equation that examined the relationships among individual and contextual variables and intragroup conflict, job satisfaction, team performance effectiveness, and anticipated turnover. The nonrandom sample consisted of 141 nurses employed on 13 inpatient units at a state-supported, 597-bed academic medical centre in a southeastern city. Intragroup conflict was higher on smaller units with a higher ratio of RNs to total staff. Intragroup conflict was not associated with satisfaction with pay or anticipated turnover. In the final model, the unit morale and interpersonal relations dimension of team performance effectiveness was negatively associated with intragroup conflict and anticipated turnover, and positively associated with satisfaction with pay. High perceptions of unit morale and interpersonal relations buffered the effect of unit size and skill mix on intragroup conflict. Goodness of fit statistics indicated a good fit of the model to data. The findings have implications for nursing educators and administrators, and provide direction for future research.

  15. Sampling pig farms at the abattoir in a cross-sectional study − Evaluation of a sampling method

    DEFF Research Database (Denmark)

    Birkegård, Anna Camilla; Hisham Beshara Halasa, Tariq; Toft, Nils

    2017-01-01

    slaughter pigs. It was not possible to visit farms within the designated timeframe. Therefore, it was decided to use convenience sampling at the abattoir. Our approach was carried out in three steps: 1) planning: using data from meat inspection to plan at which abattoirs and how many farms to sample; 2......A cross-sectional study design is relatively inexpensive, fast and easy to conduct when compared to other study designs. Careful planning is essential to obtaining a representative sample of the population, and the recommended approach is to use simple random sampling from an exhaustive list...... of units in the target population. This approach is rarely feasible in practice, and other sampling procedures must often be adopted. For example, when slaughter pigs are the target population, sampling the pigs on the slaughter line may be an alternative to on-site sampling at a list of farms. However...

  16. Analysis of Novo-Voronezh NPP unit 3 radiation lifetime of the WWER-440 reactor pressure vessel given samplings

    International Nuclear Information System (INIS)

    Kiselyov, V.; Korinets, A.; Maksimov, Yu.; Piminov, V.

    1997-01-01

    The analysis of the residual radiation lifetime of the Novo-Voronezh NPP Unit 3 reactor pressure vessel which had spherical samplings after annealing was performed for the spectrum of the 'worst' modes of the emergency situation category. For the residual radiation lifetime estimation within the given study, two approaches to determine stress intensity factors, K I , have been used simultaneously. The first approach included a direct numeric modelling of postulated cracks in the cut-out zone with the use of the 3D finite element method. The second approach included K 1 calculation using 3D weight functions calculated with the use of the boundary element method. For K I , calculation flaws have been postulated as surface longitudinal semielliptical flaws located in the deepest point of a cut-out. The results of K I calculations obtained using different methods were practically the same. The allowable critical brittleness temperature was determined as 175 C that permitted the extension of the radiation lifetime by up to 6 years after annealing. (orig.)

  17. Physico-chemical characteristics of water sample from Aiba Stream ...

    African Journals Online (AJOL)

    This study aimed at assessing the effectiveness of solar distillation in purification of water. The water sample collected from Aiba stream was subjected to double slope solar water distillation unit. The physico- chemical characteristics of the raw sample and the distillate were determined using standard methods. The.

  18. Examinations of fuel debris samples from Three Mile Island Unit 2

    International Nuclear Information System (INIS)

    Nagase, Fumihisa

    2012-01-01

    In the accident at the Fukushima-Daiichi nuclear power plants, fuels were molten due to loss of coolant and heat-up of the reactor core. Information on properties of molten fuels (debris) is important to analyze progress of the accident, estimate the status inside the damaged reactors and work on a plan for debris removal. Extensive examinations for properties of debris have been conducted after the accident at the Three Mile Island Unit 2 in 1979. The Japan Atomic Energy Agency conducted a part of the examinations in the frame of the OECD/NEA Three Mile Island Vessel Investigation Program. This issue report outline and main results of the TMI-2 debris examination programs. (author)

  19. Stability of carboxyhemoglobin in stored and mailed blood samples.

    Science.gov (United States)

    Hampson, Neil B

    2008-02-01

    Elevated blood carboxyhemoglobin (COHb) levels are used to confirm a clinical diagnosis of exposure to carbon monoxide (CO) and, in some instances, assess severity of poisoning. However, many hospital laboratories cannot measure COHb because they do not have CO-oximeters. In such instances, blood samples are often sent to outside laboratories or with a transported patient for measurement at the receiving hospital. This study was conducted to assess the stability of COHb in stored and mailed blood samples anticoagulated with heparin. Adult human blood was drawn into standard sample tubes anticoagulated with sodium heparin. Carbon monoxide gas was infused to raise the COHb level to 25% to 35%. Samples were then refrigerated or stored at room temperature, and serial COHb determinations were performed for 28 days. Additional samples were measured after being mailed locally or across the United States and back. No significant changes in COHb levels were seen in samples stored either in refrigeration or at room temperature over a period of 28 days or in samples shipped without refrigeration locally or across the United States. Carboxyhemoglobin levels in whole blood samples anticoagulated with heparin are stable with or without refrigeration for up to 4 weeks. If COHb measurement capability is not available, such samples may be shipped or transported with patients with confidence that the COHb level will be stable when measured at a later time.

  20. 40 CFR 62.14525 - Can my combustion unit be exempt from this subpart?

    Science.gov (United States)

    2010-07-01

    ....2558. (o) Laboratory units. Units that burn samples of materials for the purpose of chemical or... POLLUTANTS Federal Plan Requirements for Commercial and Industrial Solid Waste Incineration Units That... specified in this section and in § 62.14531. (a) Pathological waste incineration units. Incineration units...

  1. Attitudes toward Bisexual Men and Women among a Nationally Representative Probability Sample of Adults in the United States.

    Science.gov (United States)

    Dodge, Brian; Herbenick, Debby; Friedman, M Reuel; Schick, Vanessa; Fu, Tsung-Chieh Jane; Bostwick, Wendy; Bartelt, Elizabeth; Muñoz-Laboy, Miguel; Pletta, David; Reece, Michael; Sandfort, Theo G M

    2016-01-01

    As bisexual individuals in the United States (U.S.) face significant health disparities, researchers have posited that these differences may be fueled, at least in part, by negative attitudes, prejudice, stigma, and discrimination toward bisexual individuals from heterosexual and gay/lesbian individuals. Previous studies of individual and social attitudes toward bisexual men and women have been conducted almost exclusively with convenience samples, with limited generalizability to the broader U.S. Our study provides an assessment of attitudes toward bisexual men and women among a nationally representative probability sample of heterosexual, gay, lesbian, and other-identified adults in the U.S. Data were collected from the 2015 National Survey of Sexual Health and Behavior (NSSHB), via an online questionnaire with a probability sample of adults (18 years and over) from throughout the U.S. We included two modified 5-item versions of the Bisexualities: Indiana Attitudes Scale (BIAS), validated sub-scales that were developed to measure attitudes toward bisexual men and women. Data were analyzed using descriptive statistics, gamma regression, and paired t-tests. Gender, sexual identity, age, race/ethnicity, income, and educational attainment were all significantly associated with participants' attitudes toward bisexual individuals. In terms of responses to individual scale items, participants were most likely to "neither agree nor disagree" with all attitudinal statements. Across sexual identities, self-identified other participants reported the most positive attitudes, while heterosexual male participants reported the least positive attitudes. As in previous research on convenience samples, we found a wide range of demographic characteristics were related with attitudes toward bisexual individuals in our nationally-representative study of heterosexual, gay/lesbian, and other-identified adults in the U.S. In particular, gender emerged as a significant characteristic

  2. 7 CFR 51.308 - Methods of sampling and calculation of percentages.

    Science.gov (United States)

    2010-01-01

    ..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples Methods of Sampling and Calculation of Percentages § 51.308 Methods of sampling and calculation of percentages. (a) When the numerical... 7 Agriculture 2 2010-01-01 2010-01-01 false Methods of sampling and calculation of percentages. 51...

  3. UMTRA project water sampling and analysis plan, Mexican Hat, Utah

    International Nuclear Information System (INIS)

    1994-04-01

    The Mexican Hat, Utah, Uranium Mill Tailings Remedial Action (UMTRA) Project site is a former uranium mill that is undergoing surface remediation in the form of on-site tailings stabilization. Contaminated surface materials from the Monument Valley, Arizona, UMTRA Project site have been transported to the Mexican Hat site and are being consolidated with the Mexican Hat tailings. The scheduled completion of the tailings disposal cell is August 1995. Water is found in two geologic units at the site: the Halgaito Shale Formation and the Honaker Trail Formation. The tailings rest on the Halgaito Shale, and water contained in that unit is a result of milling activities and, to a lesser extent, water released from the tailings from compaction during remedial action construction of the disposal cell. Water in the Halgaito Shale flows through fractures and discharges at seeps along nearby arroyos. Flow from the seeps will diminish as water drains from the unit. Ground water in the lower unit, the Honaker Trail Formation, is protected from contamination by an upward hydraulic gradient. There are no nearby water supply wells because of widespread poor background ground water quality and quantity, and the San Juan River shows no impacts from the site. This water sampling and analysis plan (WSAP) recommends sampling six seeps and one upgradient monitor well compared in the Honaker Trail Formation. Samples will be taken in April 1994 (representative of high group water levels) and September 1994 (representative of low ground water levels). Analyses will be performed on filtered samples for plume indicator parameters

  4. Contaminant Attenuation and Transport Characterization of 200-DV-1 Operable Unit Sediment Samples

    Energy Technology Data Exchange (ETDEWEB)

    Truex, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Szecsody, James E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Qafoku, Nikolla [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Strickland, Christopher E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Moran, James J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lee, Brady D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Snyder, Michelle M.V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lawter, Amanda R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Resch, Charles T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gartman, Brandy N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhong, Lirong [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Nims, Megan K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Saunders, Danielle L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Williams, Benjamin D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Horner, Jacob A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Leavy, Ian I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Baum, Steven R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Christiansen, Beren B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Clayton, Ray E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McElroy, Erin M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Appriou, Delphine [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tyrrell, Kimberly J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Striluk, Miranda L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-05-15

    A laboratory study was conducted to quantify contaminant attenuation processes and associated contaminant transport parameters that are needed to evaluate transport of contaminants through the vadose zone to the groundwater. The laboratory study information, in conjunction with transport analyses, can be used as input to evaluate the feasibility of Monitored Natural Attenuation and other remedies for the 200-DV-1 Operable Unit at the Hanford Site.

  5. A simple nonstationary-volatility robust panel unit root test

    NARCIS (Netherlands)

    Demetrescu, Matei; Hanck, Christoph

    2012-01-01

    We propose an IV panel unit root test robust to nonstationary error volatility. Its finite-sample performance is convincing even for many units and strong cross-correlation. An application to GDP prices illustrates the inferential impact of nonstationary volatility. (C) 2012 Elsevier B.V. All rights

  6. Age-related motor unit remodeling in the Tibialis Anterior.

    Science.gov (United States)

    Siddiqi, Ariba; Kumar, Dinesh; Arjunan, Sridhar

    2015-01-01

    Limited studies exist on the use of surface electromyogram (EMG) signal features to detect age-related motor unit remodeling in the Tibialis Anterior. Motor unit remodeling leads to declined muscle strength and force steadiness during submaximal contractions which are factors for risk of falls in the elderly. This study investigated the remodeling phenomena in the Tibialis Anterior using sample entropy and higher order statistics. Eighteen young (26.1 ± 2.9 years) and twelve elderly (68.7 ± 9.0 years) participants performed isometric dorsiflexion of the ankle at 20% maximal voluntary contraction (MVC) and their Tibialis Anterior (TA) EMG was recorded. Sample entropy, Gaussianity and Linearity Test statistics were calculated from the recorded EMG for each MVC. Shapiro-Wilk test was used to determine normality, and either a two-tail student t-test or Wilcoxon rank sum test was performed to determine significant difference in the EMG features between the young and old cohorts. Results show age-related motor unit remodeling to be depicted by decreased sample entropy (p <; 0.1), increased non-Gaussianity (p <; 0.05) and lesser degree of linearity in the elderly. This is due to the increased sparsity of the MUAPs as a result of the denervation-reinnervation process, and the decrease in total number of motor units.

  7. Phase 2 Sampling Plan for Chestnut Ridge Operable Unit 2 (Filled Coal Ash Pond/Upper McCoy Branch) at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1993-01-01

    CDM Federal Programs Corporation (CDM Federal) was contracted by Energy Systems to prepare a Phase II Sampling Plan to describe the field investigation work necessary to address regulatory agency review comments on the Remedial Investigation of the Filled Coal Ash Pond (FCAP)/Upper McCoy Branch, Chestnut Ridge Operable Unit 2 at the Y-12 Plant, conducted by CH2M Hill in 1990. The scope and approach of the field investigation described in this plan specifically focus on deficiencies noted by the regulators in discussions at the comment resolution meeting of May 8, 1992, in Oak Ridge, Tennessee. This Phase II Sampling Plan includes a field sampling plan, a field and laboratory quality assurance project plan, a health and safety plan, a waste management plan, and appendixes providing an update to the applicable or relevant and appropriate requirements for this site and field and laboratory testing methods and procedures

  8. On some common practices of systematic sampling

    OpenAIRE

    Zhang, Li-Chun

    2006-01-01

    With permission from Statistics Sweden. The original publication is available at http://www.jos.nu/Contents/jos_online.asp Artikkelen er også utgitt i Statistisk sentralbyrås serie Særtrykk/Reprints nr 325. Systematic sampling is widely used technique in survey sampling. It is easy to execute, whether the units are to be selected with equal probability or with probabilities proportional to auxiliary sizes. It can be very efficient if one manage to achieve favourable stratification effect...

  9. [Survival strategy of photosynthetic organisms. 1. Variability of the extent of light-harvesting pigment aggregation as a structural factor optimizing the function of oligomeric photosynthetic antenna. Model calculations].

    Science.gov (United States)

    Fetisova, Z G

    2004-01-01

    In accordance with our concept of rigorous optimization of photosynthetic machinery by a functional criterion, this series of papers continues purposeful search in natural photosynthetic units (PSU) for the basic principles of their organization that we predicted theoretically for optimal model light-harvesting systems. This approach allowed us to determine the basic principles for the organization of a PSU of any fixed size. This series of papers deals with the problem of structural optimization of light-harvesting antenna of variable size controlled in vivo by the light intensity during the growth of organisms, which accentuates the problem of antenna structure optimization because optimization requirements become more stringent as the PSU increases in size. In this work, using mathematical modeling for the functioning of natural PSUs, we have shown that the aggregation of pigments of model light-harvesting antenna, being one of universal optimizing factors, furthermore allows controlling the antenna efficiency if the extent of pigment aggregation is a variable parameter. In this case, the efficiency of antenna increases with the size of the elementary antenna aggregate, thus ensuring the high efficiency of the PSU irrespective of its size; i.e., variation in the extent of pigment aggregation controlled by the size of light-harvesting antenna is biologically expedient.

  10. Detrital zircons from samples of five Neo proterozoic sandstone units deposited on Uruguay and Argentina: about evolution of paleographic Rio de la Plata craton

    International Nuclear Information System (INIS)

    Gaucher, C.; Poire, D.G.; Pamoukaghlian, K.; Gomez Peral, L.; Finney, S.; Valencia, V.; Blanco, G.

    2007-01-01

    We report U-Pb ages of detrital zircons from samples of five Neoproterozoic sandstone units deposited on the Rio de la Plata Craton (RPC) in Uruguay and Argentina. Quartz-arenites of the Piedras de Afilar Formation show typical Transamazonian ages, with peaks at 2.00-2.07, 1.87 and 1.78 Ga. However, the most important zircon population is Mesoproterozoic, showing maxima at 1.49, 1.35, 1.25 and 1.0 Ga. Zircons recovered from two sandstone levels in the Arroyo del Soldado Group (Yerbal and Cerros San Francisco formations) are mostly Archean in age, with maxima at 3.2 and 2.7 Ga. Palaeoproterozoic zircons are also prominent in this unit, with peaks at 2.45 and 2.18, with the latter a typical Transamazonian age. Two samples from the Sierras Bayas Group in Tandilia (Argentina) show different age spectra. Sandstones of the Villa Monica Formation show a unimodal zircon population of Transamazonian age (peak at 2.13 Ga). Sandstones of the Cerro Largo Formation are characterized by a dominant Transamazonian zircon population (peaks at 2.15, 2.0 and 1.79), but also important Archean-lowermost Palaeoproterozoic (3.33, 2.99, 2.7, 2.47 Ga) and Mesoproterozoic peaks (1.55, 1.23 and 1.06). The abundance of Mesoproterozoic detrital zircons is surprising. A proto-Andean, Mesoproterozoic belt is suggested as the source of the Mesoproterozoic detritus. Archean rocks of the RPC crop out only in the Nico Perez Terrane in Uruguay, suggesting that the Nico Perez Terrane was much closer to Tandilia than it is today. The sinistral reactivation of the Sarandi del Yi Shear Zone in the Cambrian, as a result of tangential collision of the Cuchilla Dionisio-Pelotas Terrane, may explain this observations. The absence of Neoproterozoic zircons shows that the studied units were deposited in a stable continental margin opening to the East and South. These Neoproterozoic basins had obviously no contribution whatsoever from Brasiliano-Pan African belts, supporting the idea of Cambrian terrane

  11. Household pesticide usage in the United States.

    Science.gov (United States)

    Savage, E P; Keefe, T J; Wheeler, H W; Mounce, L; Helwic, L; Applehans, F; Goes, E; Goes, T; Mihlan, G; Rench, J; Taylor, D K

    1981-01-01

    A total of 10,000 U.S. households in 25 standard metropolitan statistical areas and 25 counties were included in the United States. More than 8,200 households granted an interview. Nine of every ten households in the United States used some types of pesticide in their house, garden, or yard. Households in the southeastern United States used the most pesticides. Although more than 500 different pesticide formulations were used by the sampled households, 15 pesticides accounted for 65.5% of all pesticides reported in this study. Thirteen of these 15 pesticides were insecticides, one was a herbicide, and one was a rodenticide.

  12. [Molecular epidemiology and antifungal susceptibility of Candida species isolated from urine samples of patients in intensive care unit].

    Science.gov (United States)

    Yüksekkaya, Serife; Fındık, Duygu; Arslan, Uğur

    2011-01-01

    The aims of this study were to analyse the amphotericin B and fluconazole susceptibility and molecular epidemiology of Candida strains (Candida albicans, Candida tropicalis and Candida glabrata) isolated from the urine samples of patients hospitalized in the intensive care unit. Identification of the isolates was done according to microscopic morphology (chlamydospor, blastospor, pseudohyphae and true hyphae) on cornmeal agar, germ tube formation and carbohydrate assimilation patterns (API ID 32C bioMérieux, France). Antifungal susceptibilities of the isolates were determined by in vitro broth microdilution method recommended by Clinical and Laboratory Standards Institute (CLSI). To investigate the clonal relationship of the isolates, randomly amplified polymorphic DNA (RAPD) analysis was performed by using Cnd3 primer. Of the 56 Candida isolates minimum inhibitory concentration (MIC) ranges, MIC50 and MIC90 values for amphotericin B were 0.125-1 µg/ml, 0.125 and 0.5 µg/ml for C.albicans, 0.125-1 µg/ml, 0.25 and 1 µg/ml for C.tropicalis and 0.125-1 µg/ml, 0.25 and 1 µg/ml for C.glabrata, respectively. Fluconazole MIC ranges, MIC50 and MIC90 values were 0.25-4 µg/ml, 0.25 and 0.5 µg/ml for C.albicans, 0.25-16 µg/ml, 0.5 and 1 µg/ml for C.tropicalis and 0.5-64 µg/ml, 8 and 16 µg/ml for C.glabrata, respectively. For amphotericin B, none of the isolates had high MIC values (MIC > 1 µg/ml). While one of the C.glabrata isolates was resistant to fluconazole (MIC ≥ 64 µg/ml), one C.tropicalis and two C.glabrata isolates were dose-dependent susceptible (MIC: 16-32 µg/ml). The results of RAPD analysis indicated an exogenous spread from two clones for C.albicans, one clone for C.glabrata and one clone for C.tropicalis. This study underlines the importance of molecular epidemiological analysis of clinical samples together with hospital environmental samples in terms of Candida spp. To determine the exogenous origin for the related strains and to prevent

  13. Determination of beta-adrenergic receptor blocking pharmaceuticals in united states wastewater effluent

    Energy Technology Data Exchange (ETDEWEB)

    Huggett, D.B.; Khan, I.A.; Foran, C.M.; Schlenk, D

    2003-02-01

    This is the first report of beta-adrenergic receptor antagonist pharmaceuticals in United States wastewater effluent. - Beta adrenergic receptor antagonists ({beta}-Blockers) are frequently prescribed medications in the United States and have been identified in European municipal wastewater effluent, however no studies to date have investigated these compounds in United States wastewater effluent. Municipal wastewater effluent was collected from treatment facilities in Mississippi, Texas, and New York to investigate the occurrence of metoprolol, nadolol, and propranolol. Propranolol was identified in all wastewater samples analyzed (n=34) at concentrations {<=}1.9 {mu}g/l. Metoprolol and nadolol were identified in {>=}71% of the samples with concentrations of metoprolol {<=}1.2 {mu}g/l and nadolol {<=}0.36 {mu}g/l. Time course studies at both Mississippi plants and the Texas plant indicate that concentrations of propranolol, metoprolol, and nadolol remain relatively constant at each sampling period. This study indicates that {beta}-Blockers are present in United States wastewater effluent in the ng/l to {mu}g/l range.

  14. The Effect of Self-Control on Unit and Item Nonresponse in an Adolescent Sample

    Science.gov (United States)

    Watkins, Adam M.; Melde, Chris

    2007-01-01

    In "A General Theory of Crime", Gottfredson and Hirschi dispute whether valid self-report data can be collected among respondents lacking self-control. This research tests this argument by examining two processes that undermine the validity of self-report data: unit and item nonresponse. Specifically, this research addresses two questions: Within…

  15. Attitudes toward Bisexual Men and Women among a Nationally Representative Probability Sample of Adults in the United States

    Science.gov (United States)

    Herbenick, Debby; Friedman, M. Reuel; Schick, Vanessa; Fu, Tsung-Chieh (Jane); Bostwick, Wendy; Bartelt, Elizabeth; Muñoz-Laboy, Miguel; Pletta, David; Reece, Michael; Sandfort, Theo G. M.

    2016-01-01

    As bisexual individuals in the United States (U.S.) face significant health disparities, researchers have posited that these differences may be fueled, at least in part, by negative attitudes, prejudice, stigma, and discrimination toward bisexual individuals from heterosexual and gay/lesbian individuals. Previous studies of individual and social attitudes toward bisexual men and women have been conducted almost exclusively with convenience samples, with limited generalizability to the broader U.S. population. Our study provides an assessment of attitudes toward bisexual men and women among a nationally representative probability sample of heterosexual, gay, lesbian, and other-identified adults in the U.S. Data were collected from the 2015 National Survey of Sexual Health and Behavior (NSSHB), via an online questionnaire with a probability sample of adults (18 years and over) from throughout the U.S. We included two modified 5-item versions of the Bisexualities: Indiana Attitudes Scale (BIAS), validated sub-scales that were developed to measure attitudes toward bisexual men and women. Data were analyzed using descriptive statistics, gamma regression, and paired t-tests. Gender, sexual identity, age, race/ethnicity, income, and educational attainment were all significantly associated with participants' attitudes toward bisexual individuals. In terms of responses to individual scale items, participants were most likely to “neither agree nor disagree” with all attitudinal statements. Across sexual identities, self-identified other participants reported the most positive attitudes, while heterosexual male participants reported the least positive attitudes. As in previous research on convenience samples, we found a wide range of demographic characteristics were related with attitudes toward bisexual individuals in our nationally-representative study of heterosexual, gay/lesbian, and other-identified adults in the U.S. In particular, gender emerged as a significant

  16. Mathematics beliefs and achievement of a national sample of Native American students: results from the Trends in International Mathematics and Science Study (TIMSS) 2003 United States assessment.

    Science.gov (United States)

    House, J Daniel

    2009-04-01

    Recent mathematics assessment findings indicate that Native American students tend to score below students of the ethnic majority. Findings suggest that students' beliefs about mathematics are significantly related to achievement outcomes. This study examined relations between self-beliefs and mathematics achievement for a national sample of 130 Grade 8 Native American students from the Trends in International Mathematics and Science Study (TIMSS) 2003 United States sample of (M age = 14.2 yr., SD = 0.5). Multiple regression indicated several significant relations of mathematics beliefs with achievement and accounted for 26.7% of the variance in test scores. Students who earned high test scores tended to hold more positive beliefs about their ability to learn mathematics quickly, while students who earned low scores expressed negative beliefs about their ability to learn new mathematics topics.

  17. Sexual behaviors, relationships, and perceived health among adult men in the United States: results from a national probability sample.

    Science.gov (United States)

    Reece, Michael; Herbenick, Debby; Schick, Vanessa; Sanders, Stephanie A; Dodge, Brian; Fortenberry, J Dennis

    2010-10-01

    To provide a foundation for those who provide sexual health services and programs to men in the United States, the need for population-based data that describes men's sexual behaviors and their correlates remains. The purpose of this study was to, in a national probability survey of men ages 18-94 years, assess the occurrence and frequency of sexual behaviors and their associations with relationship status and health status. A national probability sample of 2,522 men aged 18 to 94 completed a cross-sectional survey about their sexual behaviors, relationship status, and health. Relationship status; health status; experience of solo masturbation, partnered masturbation, giving oral sex, receiving oral sex, vaginal intercourse and anal intercourse, in the past 90 days; frequency of solo masturbation, vaginal intercourse and anal intercourse in the past year. Masturbation, oral intercourse, and vaginal intercourse are prevalent among men throughout most of their adult life, with both occurrence and frequency varying with age and as functions of relationship type and physical health status. Masturbation is prevalent and frequent across various stages of life and for both those with and without a relational partner, with fewer men with fair to poor health reporting recent masturbation. Patterns of giving oral sex to a female partner were similar to those for receiving oral sex. Vaginal intercourse in the past 90 days was more prevalent among men in their late 20s and 30s than in the other age groups, although being reported by approximately 50% of men in the sixth and seventh decades of life. Anal intercourse and sexual interactions with other men were less common than all other sexual behaviors. Contemporary men in the United States engage in diverse solo and partnered sexual activities; however, sexual behavior is less common and more infrequent among older age cohorts. © 2010 International Society for Sexual Medicine.

  18. Self Inflicted Injuries among Children in United States - estimates from a nationwide emergency department sample.

    Directory of Open Access Journals (Sweden)

    Naseem Sulyman

    Full Text Available OBJECTIVE: The objectives of the current study are to provide nationally representative estimates of hospital based emergency department visits (ED attributed to self inflicted injuries and attempted suicides among children in United States; and to identify potential methods of such intentional self inflicted injuries and attempted suicides. METHODS: The Nationwide Emergency Department Sample (year 2007 was used. All ED visits occurring among children (aged ≤18 years with an External Cause of Injury for any of self inflicted injuries were selected. Outcomes examined include hospital ED charges and hospitalization charges. All estimates were projected to national levels. RESULTS: 77,420 visits to hospital based emergency departments were attributed to self inflicted injuries among children (26,045 males and 51,370 females. The average age of the ED visits was 15.7 years. 134 patients died in ED's (106 males and 28 females and 93 died in hospitals following in-patient admission (75 males and 18 females. A greater proportion of male ED visits were discharged routinely as opposed to female ED visits (51.1% versus 44%. A greater proportion of male ED visits also died in the emergency departments compared to female visits (0.4% versus 0.05%. 17,965 ED visits necessitated admission into same hospital. The mean charge for each ED visit was $1,874. Self inflicted injuries by poisoning were the most frequently reported sources accounting for close to 70% of all ED visits. CONCLUSIONS: Females comprise a greater proportion of ED visits attributed to self inflicted injuries. 227 children died either in the ED's or in hospitals. The current study results highlight the burden associated with such injuries among children.

  19. Experimental study of glass sampling devices

    International Nuclear Information System (INIS)

    Jouan, A.; Moncouyoux, J.P.; Meyere, A.

    1992-01-01

    Two high-level liquid waste containment glass sampling systems have been designed and built. The first device fits entirely inside a standard glass storage canister, and may thus be used in facilities not initially designed for this function. It has been tested successfully in the nonradioactive prototype unit at Marcoule. The work primarily covered the design and construction of an articulated arm supporting the sampling vessel, and the mechanisms necessary for filling the vessel and recovering the sample. System actuation and operation are fully automatic, and the resulting sample is representative of the glass melt. Implementation of the device is delicate however, and its reliability is estimated at about 75%. A second device was designed specifically for new vitrification facilities. It is installed directly on the glass melting furnace, and meets process operating and quality control requirements. Tests conducted at the Marcoule prototype vitrification facility demonstrated the feasibility of the system. Special attention was given to the sampling vessel transfer mechanisms, with two filling and controlled sample cooling options

  20. Fallout Concentration Various Environmental Samples in Indonesia

    International Nuclear Information System (INIS)

    Sutarman

    2001-01-01

    The testing of nuclear weapons have been carried out by the advanced countries, such as United States, Russian Federation, United Kingdom, France, China, India and Pakistan, since about 1945 until 1998. Nuclear weapons tests were conducted at various locations, on and above the earth's surface or underground or on and under the ocean's surface. Nuclear explosions caused the radionuclides of fission product, such as 131 l, 89 Sr, 90 Sr, 134 Cs, 137 Cs, and 239 Pu released to the atmospheric layer. In the atmospheric layer, the long-lived radionuclides, i.e, 90 Sr dan 137 Cs will be distributed into the environment as the fallout radionuclides, and deposited in the various environmental samples (soil, water, and biota). In general, at several locations in Indonesia the 90 Sr and 137 Cs in the various environmental samples still can be detected. The data of measurement results of 90 Sr and 137 Cs concentrations were generally lower than that from some countries in the northern hemisphere. (author)

  1. Apollo 15 mare units and their petrogenesis

    International Nuclear Information System (INIS)

    Binder, A.A.

    1985-01-01

    Samples from 12 different mare sites were identified and classified among the Apollo 15 samples. The genesis of the Apollo 15 mare units is summarized given the general model of mare basalt source regions and of more basalt genesis derived from a synthesis of the major oxide/major mineral, compatible siderophile, and incompatible trace element data and isotopic ratios of the Rb/Sr and Sm/Nd systems

  2. The Prevalence of ADHD-Like Symptoms in a Community Sample

    Science.gov (United States)

    Alloway, Tracy; Elliott, Julian; Holmes, Joni

    2010-01-01

    Objective: The aim of the present study was to explore the prevalence of ADHD symptoms in a community sample of children in the United Kingdom. Method: There were 964 ten year olds (55% boys; M = 10.4 years; SD = 0.6) from mainstream schools in the United Kingdom in this study. The ADHD Rating Scale-IV, which provides ratings on the frequency of…

  3. Confirmatory Sampling and Analysis Plan for the Lower East Fork Poplar Creek operable unit, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1996-04-01

    On December 21, 1989, the EPA placed the US Department of Energy's (DOE's) Oak Ridge Reservation (ORR) on the National Priorities List (NPL). On January 1, 1992, a Federal Facilities Agreement (FFA) between the DOE Field Office in Oak Ridge (DOE-OR), EPA Region IV, and the Tennessee Department of Environment and Conservation (TDEC) went into effect. This FFA establishes the procedural framework and schedule by which DOE-OR will develop, coordinate, implement and monitor environmental restoration activities on the ORR in accordance with applicable federal and state environmental regulations. The DOE-OR Environmental Restoration Program for the ORR addresses the remediation of areas both within and outside the ORR boundaries. This sampling and analysis plan focuses on confirming the cleanup of the stretch of EFPC flowing from Lake Reality at the Y-12 Plant through the City of Oak Ridge, to Poplar Creek on the ORR and its associated floodplain. Both EFPC and its floodplain have been contaminated by releases from the Y-12 Plant since the mid-1950s. Because the EFPC site-designated as an ORR operable unit (OU) under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) is included on the NPL, its remediation must follow the specific procedures mandated by CERCLA, as amended by the Superfund Amendments and Reauthorization Act in 1986

  4. Confirmatory Sampling and Analysis Plan for the Lower East Fork Poplar Creek operable unit, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    On December 21, 1989, the EPA placed the US Department of Energy`s (DOE`s) Oak Ridge Reservation (ORR) on the National Priorities List (NPL). On January 1, 1992, a Federal Facilities Agreement (FFA) between the DOE Field Office in Oak Ridge (DOE-OR), EPA Region IV, and the Tennessee Department of Environment and Conservation (TDEC) went into effect. This FFA establishes the procedural framework and schedule by which DOE-OR will develop, coordinate, implement and monitor environmental restoration activities on the ORR in accordance with applicable federal and state environmental regulations. The DOE-OR Environmental Restoration Program for the ORR addresses the remediation of areas both within and outside the ORR boundaries. This sampling and analysis plan focuses on confirming the cleanup of the stretch of EFPC flowing from Lake Reality at the Y-12 Plant through the City of Oak Ridge, to Poplar Creek on the ORR and its associated floodplain. Both EFPC and its floodplain have been contaminated by releases from the Y-12 Plant since the mid-1950s. Because the EFPC site-designated as an ORR operable unit (OU) under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) is included on the NPL, its remediation must follow the specific procedures mandated by CERCLA, as amended by the Superfund Amendments and Reauthorization Act in 1986.

  5. Unit type differences in RN workgroup job satisfaction.

    Science.gov (United States)

    Boyle, Diane K; Miller, Peggy A; Gajewski, Byron J; Hart, Sara E; Dunton, Nancy

    2006-10-01

    Using cross-sectional data from the 2004 National Database of Nursing Quality Indicators (NDNQI) RN Satisfaction Survey, differences in RN workgroup job satisfaction were examined among 10 unit types--medical-surgical, step-down, critical care, pediatric, maternal-newborn, psychiatric, emergency department, rehabilitation, surgical services, and outpatient clinics and labs. The national sample included RN workgroups in 2,900 patient care units (55,516 RNs; 206 hospitals in 44 states). Workgroup satisfaction across all unit types was moderate. RN workgroups in pediatric units were the most satisfied, whereas those in surgical services and emergency department unit types were least satisfied. A consistent finding across all unit types was high satisfaction with the specific domains of nurse-to-nurse interaction, professional status, and professional development versus much lower satisfaction with task, decision making, and pay. Findings can be used to inform and develop investigations that examine specific aspects of the work environment for RN workgroups in various unit types.

  6. Hanford Site Environmental Surveillance Master Sampling Schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1999-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, ''General Environmental protection Program,'' and DOE Order 5400.5, ''Radiation Protection of the Public and the Environment.'' The sampling methods are described in the Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office, DOE/RL-91-50, Rev.2, U.S. Department of Energy, Richland, Washington. This document contains the CY1999 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes the sampling location, sample type, and analyses to be performed on the sample. In some cases, samples are scheduled on a rotating basis and may not be collected in 1999 in which case the anticipated year for collection is provided. In addition, a map is included for each media showing approximate sampling locations

  7. Estimation of Finite Population Mean in Multivariate Stratified Sampling under Cost Function Using Goal Programming

    Directory of Open Access Journals (Sweden)

    Atta Ullah

    2014-01-01

    Full Text Available In practical utilization of stratified random sampling scheme, the investigator meets a problem to select a sample that maximizes the precision of a finite population mean under cost constraint. An allocation of sample size becomes complicated when more than one characteristic is observed from each selected unit in a sample. In many real life situations, a linear cost function of a sample size nh is not a good approximation to actual cost of sample survey when traveling cost between selected units in a stratum is significant. In this paper, sample allocation problem in multivariate stratified random sampling with proposed cost function is formulated in integer nonlinear multiobjective mathematical programming. A solution procedure is proposed using extended lexicographic goal programming approach. A numerical example is presented to illustrate the computational details and to compare the efficiency of proposed compromise allocation.

  8. Description of work for 100-DR-2 Operable Unit Vadose Drilling/test pits

    International Nuclear Information System (INIS)

    Naiknimbalkar, N.

    1993-01-01

    This report describes the scope of work for the boreholes/test pits of the 100-DR-2 Operable Unit. Sampling and field activities include: Soil screening; geologic sampling; soil sampling (physical property); analytical sampling and depths; and geophysical logging

  9. Evaluation of bacterial contamination of dental unit waterlines and use of a newly designed measurement device to assess retraction of a dental chair unit.

    Science.gov (United States)

    Ji, Xue-Yue; Fei, Chun-Nan; Zhang, Ying; Zhang, Wei; Liu, Jun; Dong, Jie

    2016-08-01

    Dental unit waterline (DUWL) output water is delivered through instruments of a dental chair unit (DCU) to irrigate and cool teeth. However, these waterlines can be heavily contaminated with bacteria. The purpose of the present study was to assess retraction and investigate the contamination level and prevalence of bacteria in DUWL output water. Fifty-eight DCUs were randomly selected from 30 hospitals in 10 districts of Tianjin, one of the four special municipalities of China. A unique sampling connector was used in place of the dental handpiece to collect water samples. Evaluation of retraction was accomplished using a retraction measurement device designed in accordance with the International Standard ISO 7494-2:2015(E). A total of 263 water samples were collected, and the highest concentration of bacteria [1.8 × 10(6) colony-forming units (CFU)/mL] was found in the handpiece group. Thirty (51.72%) water samples in the handpiece group and 21 (36.21%) in the air/water syringe groups were cultured, yielding colony counts of > 500 CFU/mL. Potential infectious agents, such as Bacillus cereus, Kocuria kristinae and Pseudomonas fluorescens, were isolated from the water samples. Thirty (51.72%) DCUs failed the retraction evaluation. There was a significant, positive correlation (P < 0.05) between the concentration of bacteria in the water sample and the retracted volume. It is of paramount importance to increase compliance with the standards for controlling DUWL contamination. Routine microbial monitoring and evaluation of retraction are necessary to provide high-quality water for use in dental treatment. © 2016 FDI World Dental Federation.

  10. Determination of beta-adrenergic receptor blocking pharmaceuticals in united states wastewater effluent

    International Nuclear Information System (INIS)

    Huggett, D.B.; Khan, I.A.; Foran, C.M.; Schlenk, D.

    2003-01-01

    This is the first report of beta-adrenergic receptor antagonist pharmaceuticals in United States wastewater effluent. - Beta adrenergic receptor antagonists (β-Blockers) are frequently prescribed medications in the United States and have been identified in European municipal wastewater effluent, however no studies to date have investigated these compounds in United States wastewater effluent. Municipal wastewater effluent was collected from treatment facilities in Mississippi, Texas, and New York to investigate the occurrence of metoprolol, nadolol, and propranolol. Propranolol was identified in all wastewater samples analyzed (n=34) at concentrations ≤1.9 μg/l. Metoprolol and nadolol were identified in ≥71% of the samples with concentrations of metoprolol ≤1.2 μg/l and nadolol ≤0.36 μg/l. Time course studies at both Mississippi plants and the Texas plant indicate that concentrations of propranolol, metoprolol, and nadolol remain relatively constant at each sampling period. This study indicates that β-Blockers are present in United States wastewater effluent in the ng/l to μg/l range

  11. The relationship of motor unit size, firing rate and force.

    Science.gov (United States)

    Conwit, R A; Stashuk, D; Tracy, B; McHugh, M; Brown, W F; Metter, E J

    1999-07-01

    Using a clinical electromyographic (EMG) protocol, motor units were sampled from the quadriceps femoris during isometric contractions at fixed force levels to examine how average motor unit size and firing rate relate to force generation. Mean firing rates (mFRs) and sizes (mean surface-detected motor unit action potential (mS-MUAP) area) of samples of active motor units were assessed at various force levels in 79 subjects. MS-MUAP size increased linearly with increased force generation, while mFR remained relatively constant up to 30% of a maximal force and increased appreciably only at higher force levels. A relationship was found between muscle force and mS-MUAP area (r2 = 0.67), mFR (r2 = 0.38), and the product of mS-MUAP area and mFR (mS-MUAP x mFR) (r2 = 0.70). The results support the hypothesis that motor units are recruited in an orderly manner during forceful contractions, and that in large muscles only at higher levels of contraction ( > 30% MVC) do mFRs increase appreciably. MS-MUAP and mFR can be assessed using clinical EMG techniques and they may provide a physiological basis for analyzing the role of motor units during muscle force generation.

  12. Portable tester for determining gas content within a core sample

    Science.gov (United States)

    Garcia, F. Jr.; Schatzel, S.J.

    1998-04-21

    A portable tester is provided for reading and displaying the pressure of a gas released from a rock core sample stored within a sealed container and for taking a sample of the released pressurized gas for chemical analysis thereof for subsequent use in a modified direct method test which determines the volume of gas and specific type of gas contained within the core sample. The portable tester includes a pair of low and high range electrical pressure transducers for detecting a gas pressure; a pair of low and high range display units for displaying the pressure of the detected gas; a selector valve connected to the low and high range pressure transducers and a selector knob for selecting gas flow to one of the flow paths; control valve having an inlet connection to the sealed container; and outlets connected to: a sample gas canister, a second outlet port connected to the selector valve means for reading the pressure of the gas from the sealed container to either the low range or high range pressure transducers, and a connection for venting gas contained within the sealed container to the atmosphere. A battery is electrically connected to and supplies the power for operating the unit. The pressure transducers, display units, selector and control valve means and the battery is mounted to and housed within a protective casing for portable transport and use. 5 figs.

  13. A compact XRF unit for determining total sulphur content in coals

    International Nuclear Information System (INIS)

    Sumitra, T.; Chankow, N.; Punnachaiya, S.; Srisatit, S.

    1994-01-01

    A microcomputer based x-ray fluorescence (XRF) unit was developed for off-line determination of total sulphur content in coal samples. The unit consisted of the x-ray exciting/measuring set and the microcomputer with a plug-in interface card. An Fe-55 radioisotope was used as the exciting source while a krypton-filled proportional counter was used to measure x-rays from the samples. The x-ray spectrum was simultaneously displayed on the microcomputer screen. For quantitative determination of sulphur, the intensities of sulphur K x-rays as well as calcium K x-rays and scattered x-rays were taken into account. The unit was tested with finely-ground, dried and compressed lignite, subbituminous and bituminous samples. If was found that for low-calcium coals, the results were in good agreement with those obtained from the standard chemical analysis method within ± 0.2% and within ± 0.5%S for high-calcium coals. 2 refs., 2 tabs., 3 figs

  14. Discrete Optimization of Internal Part Structure via SLM Unit Structure-Performance Database

    Directory of Open Access Journals (Sweden)

    Li Tang

    2018-01-01

    Full Text Available The structural optimization of the internal structure of parts based on three-dimensional (3D printing has been recognized as being important in the field of mechanical design. The purpose of this paper is to present a creation of a unit structure-performance database based on the selective laser melting (SLM, which contains various structural units with different functions and records their structure and performance characteristics so that we can optimize the internal structure of parts directly, according to the database. The method of creating the unit structure-performance database was introduced in this paper and several structural units of the unit structure-performance database were introduced. The bow structure unit was used to show how to create the structure-performance database of the unit as an example. Some samples of the bow structure unit were designed and manufactured by SLM. These samples were tested in the WDW-100 compression testing machine to obtain their performance characteristics. After this, the paper collected all data regarding unit structure parameters, weight, performance characteristics, and other data; and, established a complete set of data from the bow structure unit for the unit structure-performance database. Furthermore, an aircraft part was reconstructed conveniently to be more lightweight according to the unit structure-performance database. Its weight was reduced by 36.8% when compared with the original structure, while the strength far exceeded the requirements.

  15. Recruiting hard-to-reach United States population sub-groups via adaptations of snowball sampling strategy

    Science.gov (United States)

    Sadler, Georgia Robins; Lee, Hau-Chen; Seung-Hwan Lim, Rod; Fullerton, Judith

    2011-01-01

    Nurse researchers and educators often engage in outreach to narrowly defined populations. This article offers examples of how variations on the snowball sampling recruitment strategy can be applied in the creation of culturally appropriate, community-based information dissemination efforts related to recruitment to health education programs and research studies. Examples from the primary author’s program of research are provided to demonstrate how adaptations of snowball sampling can be effectively used in the recruitment of members of traditionally underserved or vulnerable populations. The adaptation of snowball sampling techniques, as described in this article, helped the authors to gain access to each of the more vulnerable population groups of interest. The use of culturally sensitive recruitment strategies is both appropriate and effective in enlisting the involvement of members of vulnerable populations. Adaptations of snowball sampling strategies should be considered when recruiting participants for education programs or subjects for research studies when recruitment of a population based sample is not essential. PMID:20727089

  16. High explosive spot test analyses of samples from Operable Unit (OU) 1111

    Energy Technology Data Exchange (ETDEWEB)

    McRae, D.; Haywood, W.; Powell, J.; Harris, B.

    1995-01-01

    A preliminary evaluation has been completed of environmental contaminants at selected sites within the Group DX-10 (formally Group M-7) area. Soil samples taken from specific locations at this detonator facility were analyzed for harmful metals and screened for explosives. A sanitary outflow, a burn pit, a pentaerythritol tetranitrate (PETN) production outflow field, an active firing chamber, an inactive firing chamber, and a leach field were sampled. Energy dispersive x-ray fluorescence (EDXRF) was used to obtain semi-quantitative concentrations of metals in the soil. Two field spot-test kits for explosives were used to assess the presence of energetic materials in the soil and in items found at the areas tested. PETN is the major explosive in detonators manufactured and destroyed at Los Alamos. No measurable amounts of PETN or other explosives were detected in the soil, but items taken from the burn area and a high-energy explosive (HE)/chemical sump were contaminated. The concentrations of lead, mercury, and uranium are given.

  17. Hanford Site Environmental Surveillance Master Sampling Schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    2000-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, General Environmental Protection Program: and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The sampling design is described in the Operations Office, Environmental Monitoring Plan, United States Department of Energy, Richland DOE/RL-91-50, Rev.2, U.S. Department of Energy, Richland, Washington. This document contains the CY 2000 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes sampling locations, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2000 in which case the anticipated year for collection is provided. In addition, a map showing approximate sampling locations is included for each media scheduled for collection

  18. Prospective Elementary Teachers' Conceptions of Unitizing with Whole Numbers and Fractions

    Science.gov (United States)

    Tobias, Jennifer M.; Roy, George J.; Safi, Farshid

    2015-01-01

    This article examines prospective elementary teachers' conceptions of unitizing with whole numbers and fraction concepts and operations throughout a semester-long mathematics content course. Student work samples and classroom conversations are used to illustrate the types of unitizing understandings that prospective teachers bring to teacher…

  19. Sexual behaviors, relationships, and perceived health status among adult women in the United States: results from a national probability sample.

    Science.gov (United States)

    Herbenick, Debby; Reece, Michael; Schick, Vanessa; Sanders, Stephanie A; Dodge, Brian; Fortenberry, J Dennis

    2010-10-01

    Past surveys of sexual behavior have demonstrated that female sexual behavior is influenced by medical and sociocultural changes. To be most attentive to women and their sexual lives, it is important to have an understanding of the continually evolving sexual behaviors of contemporary women in the United States. The purpose of this study, the National Survey of Sexual Health and Behavior (NSSHB), was to, in a national probability survey of women ages 18-92, assess the proportion of women in various age cohorts who had engaged in solo and partnered sexual activities in the past 90 days and to explore associations with participants' sexual behavior and their relationship and perceived health status. Past year frequencies of masturbation, vaginal intercourse, and anal intercourse were also assessed. A national probability sample of 2,523 women ages 18 to 92 completed a cross-sectional internet based survey about their sexual behavior. Relationship status; perceived health status; experience of solo masturbation, partnered masturbation, giving oral sex, receiving oral sex, vaginal intercourse, anal intercourse, in the past 90 days; frequency of solo masturbation, vaginal intercourse, and anal intercourse in the past year. Recent solo masturbation, oral sex, and vaginal intercourse were prevalent among women, decreased with age, and varied in their associations with relationship and perceived health status. Recent anal sex and same-sex oral sex were uncommonly reported. Solo masturbation was most frequent among women ages 18 to 39, vaginal intercourse was most frequent among women ages 18 to 29 and anal sex was infrequently reported. Contemporary women in the United States engage in a diverse range of solo and partnered sexual activities, though sexual behavior is less common and more infrequent among older age cohorts. © 2010 International Society for Sexual Medicine.

  20. Decontamination and concrete core sampling by teleoperated robot at Fukushima Daiichi reactor buildings

    International Nuclear Information System (INIS)

    Watanabe, Masaru; Onitsuka, Hironori; Shimonabe, Noriaki; Fujita, Jun; Matsumura, Takumi; Okumura, Atsushi

    2015-01-01

    For decommissioning of Fukushima daiichi nuclear power station, reduction of the dose equivalent rates inside the reactor buildings is an important issue. Concrete core sampling from the buildings to investigate the contamination is necessary for study about effective decontamination. However, dose rate inside the reactor buildings is very high. For example, dose rate of 1st floor on the Unit 1 is 1.2 - 1820 [mSv / h], the Unit 2 is 2.5 - 220 [mSv / h] and Unit 3 is 2.2 - 4780 [mSv / h]. So it is difficult for workers to work long hours. Therefore, a teleoperated robot, named 'MHI-MEISTeR (Mitsubishi Heavy Industries - Maintenance Equipment Integrated System of Telecontrol Robot)', has been developed to conduct operations like concrete core samples from the reactor buildings. Actually, some concrete core samples from Fukushima daiichi were taken by MHI-MEISTeR. In addition, MHI-MEISTeR is designed as a versatile robot, and so it can conduct suction / blast decontamination works as well as concrete core sampling. The above operations were performed by MHI-MEISTeR in Fukushima daiichi nuclear power station. (author)

  1. Nutrition surveillance using a small open cohort: experience from Burkina Faso

    Directory of Open Access Journals (Sweden)

    Mathias Altmann

    2016-11-01

    Full Text Available Abstract Background Nutritional surveillance remains generally weak and early warning systems are needed in areas with high burden of acute under-nutrition. In order to enhance insight into nutritional surveillance, a community-based sentinel sites approach, known as the Listening Posts (LP Project, was piloted in Burkina Faso by Action Contre la Faim (ACF. This paper presents ACF’s experience with the LP approach and investigates potential selection and observational biases. Methods Six primary sampling units (PSUs were selected in each livelihood zone using the centric systematic area sampling methodology. In each PSU, 22 children aged between 6 and 24 months were selected by proximity sampling. The prevalence of GAM for each month from January 2011 to December 2013 was estimated using a Bayesian normal–normal conjugate analysis followed by PROBIT estimation. To validate the LP approach in detecting changes over time, the time trends of MUAC from LP and from five cross-sectional surveys were modelled using polynomial regression and compared by using a Wald test. The differences between prevalence estimates from the two data sources were used to assess selection and observational biases. Results The 95 % credible interval around GAM prevalence estimates using LP approach ranged between +6.5 %/−6.0 % on a prevalence of 36.1 % and +3.5 %/−2.9 % on a prevalence of 10.8 %. LP and cross-sectional surveys time trend models were well correlated (p = 0.6337. Although LP showed a slight but significant trend for GAM to decrease over time at a rate of −0.26 %/visit, the prevalence estimates from the two data sources showed good agreement over a 3-year period. Conclusions The LP methodology has proved to be valid in following trends of GAM prevalence for a period of 3 years without selection bias. However, a slight observational bias was observed, requiring a periodical reselection of the sentinel sites. This kind of surveillance

  2. Nutrition surveillance using a small open cohort: experience from Burkina Faso.

    Science.gov (United States)

    Altmann, Mathias; Fermanian, Christophe; Jiao, Boshen; Altare, Chiara; Loada, Martin; Myatt, Mark

    2016-01-01

    Nutritional surveillance remains generally weak and early warning systems are needed in areas with high burden of acute under-nutrition. In order to enhance insight into nutritional surveillance, a community-based sentinel sites approach, known as the Listening Posts (LP) Project, was piloted in Burkina Faso by Action Contre la Faim (ACF). This paper presents ACF's experience with the LP approach and investigates potential selection and observational biases. Six primary sampling units (PSUs) were selected in each livelihood zone using the centric systematic area sampling methodology. In each PSU, 22 children aged between 6 and 24 months were selected by proximity sampling. The prevalence of GAM for each month from January 2011 to December 2013 was estimated using a Bayesian normal-normal conjugate analysis followed by PROBIT estimation. To validate the LP approach in detecting changes over time, the time trends of MUAC from LP and from five cross-sectional surveys were modelled using polynomial regression and compared by using a Wald test. The differences between prevalence estimates from the two data sources were used to assess selection and observational biases. The 95 % credible interval around GAM prevalence estimates using LP approach ranged between +6.5 %/-6.0 % on a prevalence of 36.1 % and +3.5 %/-2.9 % on a prevalence of 10.8 %. LP and cross-sectional surveys time trend models were well correlated (p = 0.6337). Although LP showed a slight but significant trend for GAM to decrease over time at a rate of -0.26 %/visit, the prevalence estimates from the two data sources showed good agreement over a 3-year period. The LP methodology has proved to be valid in following trends of GAM prevalence for a period of 3 years without selection bias. However, a slight observational bias was observed, requiring a periodical reselection of the sentinel sites. This kind of surveillance project is suited to use in areas with high burden of acute under

  3. Automated Sampling and Extraction of Krypton from Small Air Samples for Kr-85 Measurement Using Atom Trap Trace Analysis

    International Nuclear Information System (INIS)

    Hebel, S.; Hands, J.; Goering, F.; Kirchner, G.; Purtschert, R.

    2015-01-01

    Atom-Trap-Trace-Analysis (ATTA) provides the capability of measuring the Krypton-85 concentration in microlitre amounts of krypton extracted from air samples of about 1 litre. This sample size is sufficiently small to allow for a range of applications, including on-site spot sampling and continuous sampling over periods of several hours. All samples can be easily handled and transported to an off-site laboratory for ATTA measurement, or stored and analyzed on demand. Bayesian sampling methodologies can be applied by blending samples for bulk measurement and performing in-depth analysis as required. Prerequisite for measurement is the extraction of a pure krypton fraction from the sample. This paper introduces an extraction unit able to isolate the krypton in small ambient air samples with high speed, high efficiency and in a fully automated manner using a combination of cryogenic distillation and gas chromatography. Air samples are collected using an automated smart sampler developed in-house to achieve a constant sampling rate over adjustable time periods ranging from 5 minutes to 3 hours per sample. The smart sampler can be deployed in the field and operate on battery for one week to take up to 60 air samples. This high flexibility of sampling and the fast, robust sample preparation are a valuable tool for research and the application of Kr-85 measurements to novel Safeguards procedures. (author)

  4. Using Environmental Variables for Studying of the Quality of Sampling in Soil Mapping

    Directory of Open Access Journals (Sweden)

    A. Jafari

    2016-02-01

    profiles, which were then described, sampled, analyzed and classified according to the USDA soil classification system (16. The basic rationale is to set up a hypercube, the axes of which are the quantiles of rasters of environmental covariates, e.g., digital elevation model. Sampling evaluation was made using the HELS algorithm. This algorithm was written based on the study of Carre et al., 2007 (3 and run in R. Results and Discussion: The covariate dataset is represented by elevation, slope and wetness index (Table 2. All data layers were interpolated to a common grid of 30 m resolution. The size of the raster layer is 421 by 711 grid cells. Each of the three covariates is divided into four quantiles (Table 2. The hypercube character space has 43, i.e. 64 strata (Figure 5. The average number of grid cells within each stratum is therefore 4677 grid cells. The map of the covariate index (Figure 6 shows some patterns representative of the covariate variability. The values of the covariate index range between 0.0045 and 5.95. This means that some strata are very dense compared to others. This index allows us to explain if high or low relative weight of the sampling units (see below is due to soil sampling or covariate density. The strata with the highest density are in the areas with high geomorphology diversity. It means that geomorphology processes can cause the diversity and variability and it is in line with the geomorphology map (Figure 2. Of the 64 strata, 30.4% represent under-sampling, 60.2% represent adequate sampling and 9.4% represent over-sampling. Regarding the covariate index, most of the under-sampling appears in the high covariate index, where soil covariates are then highly variable. Actually, it is difficult to collect field samples in these highly variable areas (Figure 7. Also, most of the over-sampling was observed in areas with alow covariate index (Figure 7. We calculated the weights of all the sampling units and showed the results in Figure 8. One 64

  5. Measuring Radionuclides in the environment: radiological quantities and sampling designs

    International Nuclear Information System (INIS)

    Voigt, G.

    1998-10-01

    One aim of the workshop was to support and provide an ICRU report committee (International Union of Radiation Units) with actual information on techniques, data and knowledge of modern radioecology when radionuclides are to be measured in the environment. It has been increasingly recognised that some studies in radioecology, especially those involving both field sampling and laboratory measurements, have not paid adequate attention to the problem of obtaining representative, unbiased samples. This can greatly affect the quality of scientific interpretation, and the ability to manage the environment. Further, as the discipline of radioecology has developed, it has seen a growth in the numbers of quantities and units used, some of which are ill-defined and which are non-standardised. (orig.)

  6. Widespread Rotavirus H in Commercially Raised Pigs, United States

    Science.gov (United States)

    Rossow, Kurt; Culhane, Marie; Goyal, Sagar; Collins, Jim; Matthijnssens, Jelle; Nelson, Martha; Ciarlet, Max

    2014-01-01

    We investigated the presence in US pigs of rotavirus H (RVH), identified in pigs in Japan and Brazil. From 204 samples collected during 2006–2009, we identified RVH in 15% of fecal samples from 10 US states, suggesting that RVH has circulated in the United States since 2002, but probably longer. PMID:24960190

  7. Sexual behavior in the United States: results from a national probability sample of men and women ages 14-94.

    Science.gov (United States)

    Herbenick, Debby; Reece, Michael; Schick, Vanessa; Sanders, Stephanie A; Dodge, Brian; Fortenberry, J Dennis

    2010-10-01

    Despite a demonstrated relationship between sexual behaviors and health, including clinical risks, little is known about contemporary sexual behavior. To assess the rates of sexual behavior among adolescents and adults in the United States. We report the recent (past month, past year) and lifetime prevalence of sexual behaviors in a nationally representative probability sample of 5,865 men and women ages 14 to 94 in the United States (2,936 men, 2,929 women). Behaviors assessed included solo masturbation, partnered masturbation, giving and receiving oral sex, vaginal intercourse, and anal intercourse. Masturbation was common throughout the lifespan and more common than partnered sexual activities during adolescence and older age (70+). Although uncommon among 14- to 15-year olds, in the past year 18.3% of 16- to 17-year-old males and 22.4% of 16- to 17-year-old females performed oral sex with an other-sex partner. Also in the past year, more than half of women and men ages 18 to 49 engaged in oral sex. The proportion of adults who reported vaginal sex in the past year was highest among men ages 25-39 and for women ages 20-29, then progressively declined among older age groups. More than 20% of men ages 25-49 and women ages 20-39 reported anal sex in the past year. Same-sex sexual behaviors occurring in the past year were uncommonly reported. Men and women engage in a diverse range of solo and partnered sexual behaviors throughout the life course. The rates of contemporary sexual behavior provided in this report will be valuable to those who develop, implement, and evaluate programs that seek to improve societal knowledge related to the prevalence of sexual behaviors and to sexual health clinicians whose work to improve sexual health among the population often requires such rates of behavior. © 2010 International Society for Sexual Medicine.

  8. Limited field investigation report for the 100-KR-4 Operable Unit

    International Nuclear Information System (INIS)

    1994-07-01

    This limited field investigation (LFI) was conducted to optimize the use of interim remedial measures (IRM) for expediting clean up while maintaining a technically sound and cost-effective program. The 100-KR-4 Operable Unit is one of four operable units associated with the 100 K Area. Operable units KR-1, KR-2 and KR-3 address contaminant sources while 100-KR-4 addresses contamination present in the underlying groundwater. The IRM decision process for groundwater operable units is based on three aspects: (1) Is the concentration greater than Hanford background? (2) Does the concentration present a medium or high human-health risk? (3) Does the concentration exceed an ecologically based applicable, relevant and appropriate requirements (ARAR) or present an environmental hazard quotient > I? The primary methods of investigation used during this LFI were the installation of monitoring wells and sampling of groundwater. The samples collected from the groundwater and soils were submitted for laboratory analysis. Boreholes were surveyed for radiological contamination using downhole geophysical techniques to further delineate the location and degree of contamination. All soil samples were screened to ascertain the presence of volatile organic compounds and radionuclides. Analytical data were subjected to validation; all first round and a minimum of 10% of subsequent round data were validated

  9. Potabilization of brackish water by electrodialysis. Study of natural samples with a laboratory unit

    International Nuclear Information System (INIS)

    Sainz Sastre, J. A.; Alonso-Lopez, J.

    1972-01-01

    Potabilization of brackish waters from Ciguela (Toledo) and Riansares (Toledo) rivers, and from wells 1 and 2 at Torre Pacheco (Murcia), as well as of sea water diluted to 5,000 ppm has been studied in process conditions optimized from experiments with synthetic solutions. The study includes: removal of suspended and organic matter, determination of limit current density, power requirements, ion selectivity and daily maximum output of the unit. (Author) 8 refs

  10. Hospitalizations for Suicide-Related Drug Poisonings and Co-Occurring Alcohol Overdoses in Adolescents (Ages 12-17) and Young Adults (Ages 18-24) in the United States, 1999-2008: Results from the Nationwide Inpatient Sample

    Science.gov (United States)

    White, Aaron M.; MacInnes, Erin; Hingson, Ralph W.; Pan, I-Jen

    2013-01-01

    Drug poisoning is the leading method of suicide-related deaths among females and third among males in the United States. Alcohol can increase the severity of drug poisonings, yet the prevalence of alcohol overdoses in suicide-related drug poisonings (SRDP) remains unclear. Data from the Nationwide Inpatient Sample was examined to determine rates…

  11. Patient and family/friend satisfaction in a sample of Jordanian Critical Care Units.

    Science.gov (United States)

    Mosleh, S; Alja'afreh, M; Lee, A J

    2015-12-01

    The aim of the study was to assess the validity of family members/friends as proxies by comparing perceptions of satisfaction with care and decision making between critically ill patients and their family/friends. A comparative, descriptive cross-sectional study. Seven Critical Care Units across four public and military hospitals in the centre and southern regions of Jordan. A modified version of the Family Satisfaction-ICU (FS-ICU) questionnaire was distributed to Critical Care Unit (CCU) patients before hospital discharge. In addition, up to two family members/close friends were also asked to complete the questionnaire. A total of 213 patients (response rate 72%) and 246 family members/friends (response rate 79%) completed and returned the questionnaire. Although the majority of family members/friends and patients were satisfied with overall care, patients were generally significantly less satisfied (mean (SD) care subscale 75.6 (17.8) and 70.9 (17.3), respectively, (p=0.005). When individual items were examined, significant differences in nursing care (family/friends 80.1 (20.7) versus patient 75.9 (22.2), p=0.038) and inclusion in decision making (family/friends 53.9 (33.2) versus patient 62.0 (34.2), p=0.010) were found. The study showed a degree of congruence between patients and their family members/friends in relation to their satisfaction with the CCU experience. Thus, views of family/friends may serve as a proxy in assessing care and decision making processes of critically ill patients. Appropriate training of the critical care team and provision of strategies to address the concerns of patients' families are needed to improve overall patient satisfaction. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Sampling and analysis plan for the 100-D Ponds voluntary remediation project

    International Nuclear Information System (INIS)

    1996-08-01

    This Sampling and Analysis Plan (SAP) describes the sampling and analytical activities which will be performed to support closure of the 100-D Ponds Resource Conservation and Recovery Act (RCRA) treatment, storage, and/or disposal (TSD) unit. This SAP includes the Field Sampling Plan (FSP) presented in Section 2.0, and the Quality Assurance Project Plan (QAPjP) described in Section 3.0. The FSP defines the sampling and analytical methodologies to be performed, and the QAPjP provides or includes information on the requirements for precision, accuracy, representativeness, comparability, and completeness of the analytical data. This sampling and analysis plan was developed using the Environmental Protection Agency's Seven-Step Data Quality Objectives (DQO) Guidance (EPA, 1994). The purpose of the DQO meetings was (1) to identify the contaminants of concern and their cleanup levels under the Washington State Model Toxics Control Act (MTCA, WAC-173-340) Method B, and (2) to determine the number and locations of samples necessary to verify that the 100-D Ponds meet the cleanup criteria. The data collected will be used to support RCRA closure of this TSD unit

  13. Hanford site environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1998-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1 open-quotes General Environmental Protection Program,close quotes and DOE Order 5400.5, open-quotes Radiation Protection of the Public and the Environment.close quotes The sampling methods are described in the Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office, DOE/RL91-50, Rev. 2, U.S. Department of Energy, Richland, Washington. This document contains the 1998 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section of this document describes the planned sampling schedule for a specific media (air, surface water, biota, soil and vegetation, sediment, and external radiation). Each section includes the sample location, sample type, and analyses to be performed on the sample. In some cases, samples are scheduled on a rotating basis and may not be planned for 1998 in which case the anticipated year for collection is provided. In addition, a map is included for each media showing sample locations

  14. Estimating HIES Data through Ratio and Regression Methods for Different Sampling Designs

    Directory of Open Access Journals (Sweden)

    Faqir Muhammad

    2007-01-01

    Full Text Available In this study, comparison has been made for different sampling designs, using the HIES data of North West Frontier Province (NWFP for 2001-02 and 1998-99 collected from the Federal Bureau of Statistics, Statistical Division, Government of Pakistan, Islamabad. The performance of the estimators has also been considered using bootstrap and Jacknife. A two-stage stratified random sample design is adopted by HIES. In the first stage, enumeration blocks and villages are treated as the first stage Primary Sampling Units (PSU. The sample PSU’s are selected with probability proportional to size. Secondary Sampling Units (SSU i.e., households are selected by systematic sampling with a random start. They have used a single study variable. We have compared the HIES technique with some other designs, which are: Stratified Simple Random Sampling. Stratified Systematic Sampling. Stratified Ranked Set Sampling. Stratified Two Phase Sampling. Ratio and Regression methods were applied with two study variables, which are: Income (y and Household sizes (x. Jacknife and Bootstrap are used for variance replication. Simple Random Sampling with sample size (462 to 561 gave moderate variances both by Jacknife and Bootstrap. By applying Systematic Sampling, we received moderate variance with sample size (467. In Jacknife with Systematic Sampling, we obtained variance of regression estimator greater than that of ratio estimator for a sample size (467 to 631. At a sample size (952 variance of ratio estimator gets greater than that of regression estimator. The most efficient design comes out to be Ranked set sampling compared with other designs. The Ranked set sampling with jackknife and bootstrap, gives minimum variance even with the smallest sample size (467. Two Phase sampling gave poor performance. Multi-stage sampling applied by HIES gave large variances especially if used with a single study variable.

  15. Improving Sampling, Analysis, and Data Management for Site Investigation and Cleanup

    Science.gov (United States)

    The United States Environmental Protection Agency (EPA) supports the adoption of streamlined approaches to sampling, analysis, and data management activities conducted during site assessment, characterization, and cleanup.

  16. International cooperation for Mars exploration and sample return

    Science.gov (United States)

    Levy, Eugene H.; Boynton, William V.; Cameron, A. G. W.; Carr, Michael H.; Kitchell, Jennifer H.; Mazur, Peter; Pace, Norman R.; Prinn, Ronald G.; Solomon, Sean C.; Wasserburg, Gerald J.

    1990-01-01

    The National Research Council's Space Studies Board has previously recommended that the next major phase of Mars exploration for the United States involve detailed in situ investigations of the surface of Mars and the return to earth for laboratory analysis of selected Martian surface samples. More recently, the European space science community has expressed general interest in the concept of cooperative Mars exploration and sample return. The USSR has now announced plans for a program of Mars exploration incorporating international cooperation. If the opportunity becomes available to participate in Mars exploration, interest is likely to emerge on the part of a number of other countries, such as Japan and Canada. The Space Studies Board's Committee on Cooperative Mars Exploration and Sample Return was asked by the National Aeronautics and Space Administration (NASA) to examine and report on the question of how Mars sample return missions might best be structured for effective implementation by NASA along with international partners. The committee examined alternatives ranging from scientific missions in which the United States would take a substantial lead, with international participation playing only an ancillary role, to missions in which international cooperation would be a basic part of the approach, with the international partners taking on comparably large mission responsibilities. On the basis of scientific strategies developed earlier by the Space Studies Board, the committee considered the scientific and technical basis of such collaboration and the most mutually beneficial arrangements for constructing successful cooperative missions, particularly with the USSR.

  17. Latex Rubber Gloves as a Sampling Dosimeter Using a Novel Surrogate Sampling Device.

    Science.gov (United States)

    Sankaran, Gayatri; Lopez, Terry; Ries, Steve; Ross, John; Vega, Helen; Eastmond, David A; Krieger, Robert I

    2015-01-01

    Pesticide exposure during harvesting of crops occurs primarily to the workers' hands. When harvesters wear latex rubber gloves for personal safety and hygiene harvesting reasons, gloves accumulate pesticide residues. Hence, characterization of the gloves' properties may be useful for pesticide exposure assessments. Controlled field studies were conducted using latex rubber gloves to define the factors that influence the transfer of pesticides to the glove and that would affect their use as a residue monitoring device. A novel sampling device called the Brinkman Contact Transfer Unit (BCTU) was constructed to study the glove characteristics and residue transfer and accumulation under controlled conditions on turf. The effectiveness of latex rubber gloves as sampling dosimeters was evaluated by measuring the transferable pesticide residues as a function of time. The validation of latex rubber gloves as a residue sampling dosimeter was performed by comparing pesticide transfer and dissipation from the gloves, with the turf transferable residues sampled using the validated California (CA) Roller, a standard measure of residue transfer. The observed correlation (Pearson's correlation coefficient R(2)) between the two methods was .84 for malathion and .96 for fenpropathrin, indicating that the BCTU is a useful, reliable surrogate tool for studying available residue transfer to latex rubber gloves under experimental conditions. Perhaps more importantly, these data demonstrate that latex gloves worn by workers may be useful quantifiable matrices for measuring pesticide exposure.

  18. Effect of mobile laminar airflow units on airborne bacterial contamination during neurosurgical procedures.

    Science.gov (United States)

    von Vogelsang, A-C; Förander, P; Arvidsson, M; Löwenhielm, P

    2018-03-24

    Surgical site infections (SSIs) after neurosurgery are potentially life-threatening and entail great costs. SSIs may occur from airborne bacteria in the operating room, and ultraclean air is desired during infection-prone cleaning procedures. Door openings and the number of persons present in the operating room affect the air quality. Mobile laminar airflow (MLAF) units, with horizontal laminar airflow, have previously been shown to reduce airborne bacterial contamination. To assess the effect of MLAF units on airborne bacterial contamination during neurosurgical procedures. In a quasi-experimental design, bacteria-carrying particles (colony-forming units: cfu) during neurosurgical procedures were measured with active air-sampling in operating rooms with conventional turbulent ventilation, and with additional MLAF units. The MLAF units were shifted between operating rooms monthly. Colony-forming unit count and bacterial species detection were conducted after incubation. Data was collected for a period of 18 months. A total of 233 samples were collected during 45 neurosurgical procedures. The use of MLAF units significantly reduced the numbers of cfu in the surgical site area (P neurosurgery to ultraclean air levels. MLAF units are valuable when the main operating room ventilation system is unable to produce ultraclean air in infection-prone clean neurosurgery. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  19. Sample Adaptive Offset Optimization in HEVC

    Directory of Open Access Journals (Sweden)

    Yang Zhang

    2014-11-01

    Full Text Available As the next generation of video coding standard, High Efficiency Video Coding (HEVC adopted many useful tools to improve coding efficiency. Sample Adaptive Offset (SAO, is a technique to reduce sample distortion by providing offsets to pixels in in-loop filter. In SAO, pixels in LCU are classified into several categories, then categories and offsets are given based on Rate-Distortion Optimization (RDO of reconstructed pixels in a Largest Coding Unit (LCU. Pixels in a LCU are operated by the same SAO process, however, transform and inverse transform makes the distortion of pixels in Transform Unit (TU edge larger than the distortion inside TU even after deblocking filtering (DF and SAO. And the categories of SAO can also be refined, since it is not proper for many cases. This paper proposed a TU edge offset mode and a category refinement for SAO in HEVC. Experimental results shows that those two kinds of optimization gets -0.13 and -0.2 gain respectively compared with the SAO in HEVC. The proposed algorithm which using the two kinds of optimization gets -0.23 gain on BD-rate compared with the SAO in HEVC which is a 47 % increase with nearly no increase on coding time.

  20. The WIPP Water Quality Sampling Program

    International Nuclear Information System (INIS)

    Uhland, D.; Morse, J.G.; Colton, D.

    1986-01-01

    The Waste Isolation Pilot Plant (WIPP), a Department of Energy facility, will be used for the underground disposal of wastes. The Water Quality Sampling Program (WQSP) is designed to obtain representative and reproducible water samples to depict accurate water composition data for characterization and monitoring programs in the vicinity of the WIPP. The WQSP is designed to input data into four major programs for the WIPP project: Geochemical Site Characterization, Radiological Baseline, Environmental Baseline, and Performance Assessment. The water-bearing units of interest are the Culebra and Magneta Dolomite Members of the Rustler Formation, units in the Dewey Lake Redbeds, and the Bell Canyon Formation. At least two chemically distinct types of water occur in the Culebra, one being a sodium/potassium chloride water and the other being a calcium/magnesium sulfate water. Water from the Culebra wells to the south of the WIPP site is distinctly fresher and tends to be of the calcium/magnesium sulfate type. Water in the Culebra in the north and around the WIPP site is distinctly fresher and tends to be of the sodium/potassium chloride type and is much higher in total dissolved solids. The program, which is currently 1 year old, will continue throughout the life of the facility as part of the Environmental Monitoring Program

  1. Support for Restorative Justice in a Sample of U.S. University Students.

    Science.gov (United States)

    Ahlin, Eileen M; Gibbs, Jennifer C; Kavanaugh, Philip R; Lee, Joongyeup

    2017-02-01

    Theories of restorative justice suggest that the practice works best when offenders are enmeshed in multiple interdependencies or attachments to others and belong to a culture that facilitates communitarianism instead of individualism. Restorative justice principles and practices are thus believed to be incongruent with the individualistic culture and legal system of the United States, especially compared with that of nations like Australia and Japan. Using a nonprobability convenience sample of students enrolled in a large public university in the United States, our study examines attitudes toward restorative justice as a fair and just process for reintegrating offenders and meeting the needs of victims. Results indicate that our sample holds less punitive attitudes than citizens in either Australia or Japan. Our findings are discussed in light of recent policy shifts in the United States that suggest a concerted move toward decarceration following the 2008 recession.

  2. Assessing the Performance of Business Unit Managers

    NARCIS (Netherlands)

    Bouwens, J.F.M.G.; van Lent, L.A.G.M.

    2006-01-01

    Using a sample of 140 managers, we investigate the use of various performance metrics in determining the periodic assessment, bonus decisions, and career paths of business unit managers.We show that the weight on accounting return measures is associated with the authority of these managers, and we

  3. Electron accelerating unit for streak image tubes

    Indian Academy of Sciences (India)

    The simulation results show that the accelerating unit improves both the spatial and temporal .... This electron emission process is simulated as a statistical sample in terms of Monte ... solver using above method in MATLAB language. First the .... semiconductors and insulators: Models and measurements. J. Phys. Rev.

  4. Vanishing auxiliary variables in PPS sampling - with applications in microscopy

    DEFF Research Database (Denmark)

    Andersen, Ina Trolle; Hahn, Ute; Jensen, Eva B. Vedel

    Recently, non-uniform sampling has been suggested in microscopy to increase efficiency. More precisely, sampling proportional to size (PPS) has been introduced where the probability of sampling a unit in the population is proportional to the value of an auxiliary variable. Unfortunately, vanishing...... auxiliary variables are a common phenomenon in microscopy and, accordingly, part of the population is not accessible, using PPS sampling. We propose a modification of the design, for which an optimal solution can be found, using a model assisted approach. The optimal design has independent interest...... in sampling theory. We verify robustness of the new approach by numerical results, and we use real data to illustrate the applicability....

  5. Effect of unit size on thermal fatigue behavior of hot work steel repaired by a biomimetic laser remelting process

    Science.gov (United States)

    Cong, Dalong; Li, Zhongsheng; He, Qingbing; Chen, Dajun; Chen, Hanbin; Yang, Jiuzhou; Zhang, Peng; Zhou, Hong

    2018-01-01

    AISI H13 hot work steel with fatigue cracks was repaired by a biomimetic laser remelting (BLR) process in the form of lattice units with different sizes. Detailed microstructural studies and microhardness tests were carried out on the units. Studies revealed a mixed microstructure containing martensite, retained austenite and carbide particles with ultrafine grain size in units. BLR samples with defect-free units exhibited superior thermal fatigue resistance due to microstructure strengthening, and mechanisms of crack tip blunting and blocking. In addition, effects of unit size on thermal fatigue resistance of BLR samples were discussed.

  6. Racialized risk environments in a large sample of people who inject drugs in the United States.

    Science.gov (United States)

    Cooper, Hannah L F; Linton, Sabriya; Kelley, Mary E; Ross, Zev; Wolfe, Mary E; Chen, Yen-Tyng; Zlotorzynska, Maria; Hunter-Jones, Josalin; Friedman, Samuel R; Des Jarlais, Don; Semaan, Salaam; Tempalski, Barbara; DiNenno, Elizabeth; Broz, Dita; Wejnert, Cyprian; Paz-Bailey, Gabriela

    2016-01-01

    Substantial racial/ethnic disparities exist in HIV infection among people who inject drugs (PWID) in many countries. To strengthen efforts to understand the causes of disparities in HIV-related outcomes and eliminate them, we expand the "Risk Environment Model" to encompass the construct "racialized risk environments," and investigate whether PWID risk environments in the United States are racialized. Specifically, we investigate whether black and Latino PWID are more likely than white PWID to live in places that create vulnerability to adverse HIV-related outcomes. As part of the Centers for Disease Control and Prevention's National HIV Behavioral Surveillance, 9170 PWID were sampled from 19 metropolitan statistical areas (MSAs) in 2009. Self-reported data were used to ascertain PWID race/ethnicity. Using Census data and other administrative sources, we characterized features of PWID risk environments at four geographic scales (i.e., ZIP codes, counties, MSAs, and states). Means for each feature of the risk environment were computed for each racial/ethnic group of PWID, and were compared across racial/ethnic groups. Almost universally across measures, black PWID were more likely than white PWID to live in environments associated with vulnerability to adverse HIV-related outcomes. Compared to white PWID, black PWID lived in ZIP codes with higher poverty rates and worse spatial access to substance abuse treatment and in counties with higher violent crime rates. Black PWID were less likely to live in states with laws facilitating sterile syringe access (e.g., laws permitting over-the-counter syringe sales). Latino/white differences in risk environments emerged at the MSA level (e.g., Latino PWID lived in MSAs with higher drug-related arrest rates). PWID risk environments in the US are racialized. Future research should explore the implications of this racialization for racial/ethnic disparities in HIV-related outcomes, using appropriate methods. Copyright © 2015

  7. Computational methods and modeling. 1. Sampling a Position Uniformly in a Trilinear Hexahedral Volume

    International Nuclear Information System (INIS)

    Urbatsch, Todd J.; Evans, Thomas M.; Hughes, H. Grady

    2001-01-01

    Monte Carlo particle transport plays an important role in some multi-physics simulations. These simulations, which may additionally involve deterministic calculations, typically use a hexahedral or tetrahedral mesh. Trilinear hexahedrons are attractive for physics calculations because faces between cells are uniquely defined, distance-to-boundary calculations are deterministic, and hexahedral meshes tend to require fewer cells than tetrahedral meshes. We discuss one aspect of Monte Carlo transport: sampling a position in a tri-linear hexahedron, which is made up of eight control points, or nodes, and six bilinear faces, where each face is defined by four non-coplanar nodes in three-dimensional Cartesian space. We derive, code, and verify the exact sampling method and propose an approximation to it. Our proposed approximate method uses about one-third the memory and can be twice as fast as the exact sampling method, but we find that its inaccuracy limits its use to well-behaved hexahedrons. Daunted by the expense of the exact method, we propose an alternate approximate sampling method. First, calculate beforehand an approximate volume for each corner of the hexahedron by taking one-eighth of the volume of an imaginary parallelepiped defined by the corner node and the three nodes to which it is directly connected. For the sampling, assume separability in the parameters, and sample each parameter, in turn, from a linear pdf defined by the sum of the four corner volumes at each limit (-1 and 1) of the parameter. This method ignores the quadratic portion of the pdf, but it requires less storage, has simpler sampling, and needs no extra, on-the-fly calculations. We simplify verification by designing tests that consist of one or more cells that entirely fill a unit cube. Uniformly sampling complicated cells that fill a unit cube will result in uniformly sampling the unit cube. Unit cubes are easily analyzed. The first problem has four wedges (or tents, or A frames) whose

  8. The development and validation of the Male Genital Self-Image Scale: results from a nationally representative probability sample of men in the United States.

    Science.gov (United States)

    Herbenick, Debby; Schick, Vanessa; Reece, Michael; Sanders, Stephanie A; Fortenberry, J Dennis

    2013-06-01

    Numerous factors may affect men's sexual experiences, including their health status, past trauma or abuse, medication use, relationships, mood, anxiety, and body image. Little research has assessed the influence of men's genital self-image on their sexual function or behaviors and none has done so in a nationally representative sample. The purpose of this study was to, in a nationally representative probability sample of men ages 18 to 60, assess the reliability and validity of the Male Genital Self-Image Scale (MGSIS), and to examine the relationship between scores on the MGSIS and men's scores on the International Index of Erectile Function (IIEF). The MGSIS was developed in two stages. Phase One involved a review of the literature and an analysis of cross-sectional survey data. Phase Two involved an administration of the scale items to a nationally representative sample of men in the United States ages 18 to 60. Measures include demographic items, the IIEF, and the MGSIS. Overall, most men felt positively about their genitals. However, 24.6% of men expressed some discomfort letting a healthcare provider examine their genitals and about 20% reported dissatisfaction with their genital size. The MGSIS was found to be reliable and valid, with the MGSIS-5 (consisting of five items) being the best fit to the data. The MGSIS was found to be a reliable and valid measure. In addition, men's scores on the MGSIS-5 were found to be positively related to men's scores on the IIEF. © 2013 International Society for Sexual Medicine.

  9. A method for determination of mass per unit area inhomogeneity of thin samples in XRF analysis

    International Nuclear Information System (INIS)

    Sitko, R.; Jurczyk, J.

    1999-01-01

    The authors have presented a simple method for the determination of possible inhomogeneity of thin samples in a wavedispersive XRF analysis after previous examination of intensity distribution of exciting radiation on sample's surface. Investigations were carried out using as an example microsamples of mono- and polycrystals. Samples were prepared by digesting an analysed material directly on the substrate. The obtained results have been presented in a graphical way. (author)

  10. Data validation report for the 100-KR-4 operable unit first quarter, 1994

    International Nuclear Information System (INIS)

    Krug, A.D.

    1994-01-01

    Samples were obtained from the 100-KR-4 Operable Unit first Quarter 1994 Groundwater Sampling event. The data from the chemical analysis of fifty-eight samples from this sampling event and their related quality assurance samples were reviewed and validated to verify that reported samples results were of sufficient quality to support decisions regarding remedial actions performed at this site. Information fro the sampling event and the information validation processes are presented in this document

  11. The beliefs in the inheritance of risk factors for suicide scale (BIRFSS): cross-cultural validation in Estonia, Malaysia, Romania, the United Kingdom, and the United States.

    Science.gov (United States)

    Voracek, Martin; Loibl, Lisa Mariella; Swami, Viren; Vintilă, Mona; Kõlves, Kairi; Sinniah, Dhachayani; Pillai, Subash Kumar; Ponnusamy, Subramaniam; Sonneck, Gernot; Furnham, Adrian; Lester, David

    2008-12-01

    The genetics of suicide is increasingly recognized and relevant for mental health literacy, but actual beliefs may lag behind current knowledge. We examined such beliefs in student samples (total N = 686) from Estonia, Malaysia, Romania, the United Kingdom, and the United States with the Beliefs in the Inheritance of Risk Factors for Suicide Scale. Cultural effects were small, those of key demographics nil. Several facets of construct validity were demonstrated. Marked differences in perceived plausibility of evidence about the genetics of suicide according to research design, observed in all samples, may be of general interest for investigating lay theories of abnormal behavior and communicating behavioral and psychiatric genetic research findings.

  12. A comparison of two sampling approaches for assessing the urban forest canopy cover from aerial photography.

    Science.gov (United States)

    Ucar Zennure; Pete Bettinger; Krista Merry; Jacek Siry; J.M. Bowker

    2016-01-01

    Two different sampling approaches for estimating urban tree canopy cover were applied to two medium-sized cities in the United States, in conjunction with two freely available remotely sensed imagery products. A random point-based sampling approach, which involved 1000 sample points, was compared against a plot/grid sampling (cluster sampling) approach that involved a...

  13. The relationship between orbital, earth-based, and sample data for lunar landing sites

    Science.gov (United States)

    Clark, P. E.; Hawke, B. R.; Basu, A.

    1990-01-01

    Results are reported of a detailed examination of data available for the Apollo lunar landing sites, including the Apollo orbital measurements of six major elements derived from XRF and gamma-ray instruments and geochemical parameters derived from earth-based spectral reflectivity data. Wherever orbital coverage for Apollo landing sites exist, the remote data were correlated with geochemical data derived from the soil sample averages for major geological units and the major rock components associated with these units. Discrepancies were observed between the remote and the soil-anlysis elemental concentration data, which were apparently due to the differences in the extent of exposure of geological units, and, hence, major rock eomponents, in the area sampled. Differences were observed in signal depths between various orbital experiments, which may provide a mechanism for explaining differences between the XRF and other landing-site data.

  14. Maintaining continuity of knowledge on safeguards samples

    International Nuclear Information System (INIS)

    Franssen, F.; Islam, A.B.M.N.; Sonnier, C.; Schoeneman, J.L.; Baumann, M.

    1992-01-01

    The conclusions of the vulnerability test on VOPAN (verification of Operator's Analysis) as conducted at Safeguards Analytical Laboratory (ASA) at Seibersdorf, Austria in October 1990 and documented in STR-266, indicate that ''whenever samples are taken for safeguards purposes extreme care must be taken to ensure that they have not been interfered with during the sample taking, transportation, storage or sample preparation process.'' Indeed there exist a number of possibilities to alter the content of a safeguards sample vial from the moment of sampling up to the arrival of the treated (or untreated) sample at SAL. The time lapse between these two events can range from a few days up to months. The sample history over this period can be subdivided into three main sub-periods: (1) the period from when the sampling activities are commenced up to the treatment in the operator's laboratory, (2) during treatment of samples in the operator's laboratory, and finally, (3) the period between that treatment and the arrival of the sample at SAL. A combined effort between the Agency and the United States Support Program to the Agency (POTAS) has resulted in two active tasks and one proposed task to investigate improving the maintenance of continuity of knowledge on safeguards samples during the entire period of their existence. This paper describes the use of the Sample Vial Secure Container (SVSC), of the Authenticated Secure Container System (ASCS), and of the Secure Container for Storage and Transportation of samples (SCST) to guarantee that a representative portion of the solution sample will be received at SAL

  15. Background noise characteristics of field effect transistors for X-ray detection units

    International Nuclear Information System (INIS)

    Gostilo, V.V.

    1990-01-01

    Energy equivalent for noise of experimental samples of field-effect transistors for X-ray detection units is investigated. Resolution of 160 eV for lines of 5.9 keV is obtained in detection unit with drain feedback using the Si(Li)-detector of 25 mm 2 by square

  16. Measurements of plutonium in environmental samples

    International Nuclear Information System (INIS)

    D'Alberti, F.; Risposi, L.

    1996-01-01

    Within the activities connected with the start up of the PETRA Laboratory (Processo per l'Estrazione di Terre Rare ed Attinidi, i.e. process for extraction of rare earths and actinides), the Radiation Protection Unit of the J.R.C.-Ispra has carried out a well planned set of experimental measurements aimed at evaluating the zero point of the isotopes of plutonium in environmental samples by alfa spectrometry. After the International Moratorium in 1963, no release of plutonium has occurred in the environment apart from the burn up of SNAP 9A satellite in April 1964. Since then the plutonium concentration in air and in fallout samples has been continuously decreasing requiring, therefore, optimization of both instrumentation and experimental measurement procedures in order to obtain better sensibilities. In this work, the experimental methodology followed at the J.R.C.-Ispra for measurements of plutonium concentration in air, deposition and soil is described and the plutonium behaviour in these samples is reported and discussed starting from 1961

  17. Measurements of plutonium in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    D' Alberti, F; Risposi, L [Instituto di Fisica Applicata, University of Milan, Milan (Italy)

    1996-01-01

    Within the activities connected with the start up of the PETRA Laboratory (Processo per l'Estrazione di Terre Rare ed Attinidi, i.e. process for extraction of rare earths and actinides), the Radiation Protection Unit of the J.R.C.-Ispra has carried out a well planned set of experimental measurements aimed at evaluating the zero point of the isotopes of plutonium in environmental samples by alfa spectrometry. After the International Moratorium in 1963, no release of plutonium has occurred in the environment apart from the burn up of SNAP 9A satellite in April 1964. Since then the plutonium concentration in air and in fallout samples has been continuously decreasing requiring, therefore, optimization of both instrumentation and experimental measurement procedures in order to obtain better sensibilities. In this work, the experimental methodology followed at the J.R.C.-Ispra for measurements of plutonium concentration in air, deposition and soil is described and the plutonium behaviour in these samples is reported and discussed starting from 1961.

  18. Microbiological Sampling Methods and Sanitation of Edible Plants Grown on ISS

    Science.gov (United States)

    Parrish, Charles H. II; Khodadad, Christina L.; Garland, Nathaniel T.; Larson, Brian D.; Hummreick, Mary E.

    2013-01-01

    Pathogenic microbes on the surfaces of salad crops and growth chambers pose a threat to the health of crew on International Space Station. For astronauts to safely consume spacegrown vegetables produced in NASA's new vegetable production unit, VEGGIE, three technical challenges must be overcome: real-time sampling, microbiological analysis, and sanitation. Raphanus sativus cultivar Cherry Bomb II and Latuca sativa cultivar Outredgeous, two saled crops to be grown in VEGGIE, were inoculated with Salmonella enterica serovar Typhimurium (S. Typhimurium), a bacterium known to cause food-borne illness Tape- and swab-based sampling techniques were optimized for use in microgravity and assessed for effectiveness in recovery of bacteria from crop surfaces: Rapid pathogen detection and molecular analyses were performed via quantitative real-time polymerase chain reactiop using LightCycler® 480 and RAZOR® EX, a scaled-down instrument that is undergoing evaluation and testing for future flight hardware. These methods were compared with conventional, culture-based methods for the recovery of S. Typhimurium colonies. A sterile wipe saturated with a citric acid-based, food-grade sanitizer was applied to two different surface materials used in VEGGIE flight hardware that had been contaminated with the bacterium Pseudomonas aeruginosa,. another known human pathogen. To sanitize surfaces, wipes were saturated with either the sanitizer or sterile deionized water and applied to each surface. Colony forming units of P. aeruginosa grown on tryptic soy agar plates were enumerated from surface samples after sanitization treatments. Depending on the VEGGIE hardware material, 2- to 4.5-log10 reductions in colony-forming units were observed after sanitization. The difference in recovery of S. Typhimurium between tape- and swab- based sampling techniques was insignificant. RAZOR® EX rapidly detected S. Typhimurium present in both raw culture and extracted DNA samples.

  19. An efficient continuous flow helium cooling unit for Moessbauer experiments

    International Nuclear Information System (INIS)

    Herbert, I.R.; Campbell, S.J.

    1976-01-01

    A Moessbauer continuous flow cooling unit for use with liquid helium over the temperature range 4.2 to 300K is described. The cooling unit can be used for either absorber or source studies in the horizontal plane and it is positioned directly on top of a helium storage vessel. The helium transfer line forms an integral part of the cooling unit and feeds directly into the storage vessel so that helium losses are kept to the minimum. The helium consumption is 0.12 l h -1 at 4.2 K decreasing to 0.055 l h -1 at 40 K. The unit is top loading and the exchange gas cooled samples can be changed easily and quickly. (author)

  20. Preparation of higher-actinide burnup and cross section samples

    International Nuclear Information System (INIS)

    Adair, H.L.; Kobisk, E.H.; Quinby, T.C.; Thomas, D.K.; Dailey, J.M.

    1981-01-01

    A joint research program involving the United States and the United Kingdom was instigated about four years ago for the purpose of studying burnup of higher actinides using in-core irradiation in the fast reactor at Dounreay, Scotland. Simultaneously, determination of cross sections of a wide variety of higher actinide isotopes was proposed. Coincidental neutron flux and energy spectral measurements were to be made using vanadium encapsulated dosimetry materials in the immediate region of the burnup and cross section samples. The higher actinide samples chosen for the burnup study were 241 Am and 244 Cm in the forms of Am 2 O 3 , Cm 2 O 3 , and Am 6 Cm(RE) 7 O 21 , where (RE) represents a mixture of lanthanide sesquioxides. It is the purpose of this paper to describe technology development and its application in the preparation of the fuel specimens and the cross section specimens that are being used in this cooperative program

  1. Sample Size for Tablet Compression and Capsule Filling Events During Process Validation.

    Science.gov (United States)

    Charoo, Naseem Ahmad; Durivage, Mark; Rahman, Ziyaur; Ayad, Mohamad Haitham

    2017-12-01

    During solid dosage form manufacturing, the uniformity of dosage units (UDU) is ensured by testing samples at 2 stages, that is, blend stage and tablet compression or capsule/powder filling stage. The aim of this work is to propose a sample size selection approach based on quality risk management principles for process performance qualification (PPQ) and continued process verification (CPV) stages by linking UDU to potential formulation and process risk factors. Bayes success run theorem appeared to be the most appropriate approach among various methods considered in this work for computing sample size for PPQ. The sample sizes for high-risk (reliability level of 99%), medium-risk (reliability level of 95%), and low-risk factors (reliability level of 90%) were estimated to be 299, 59, and 29, respectively. Risk-based assignment of reliability levels was supported by the fact that at low defect rate, the confidence to detect out-of-specification units would decrease which must be supplemented with an increase in sample size to enhance the confidence in estimation. Based on level of knowledge acquired during PPQ and the level of knowledge further required to comprehend process, sample size for CPV was calculated using Bayesian statistics to accomplish reduced sampling design for CPV. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  2. Tank 241-Z-361 vapor sampling and analysis plan

    Energy Technology Data Exchange (ETDEWEB)

    BANNING, D.L.

    1999-02-23

    Tank 241-Z-361 is identified in the Hanford Federal Facility Agreement and Consent Order (commonly referred to as the Tri-Party Agreement), Appendix C, (Ecology et al. 1994) as a unit to be remediated under the authority of the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). As such, the U.S. Environmental Protection Agency will serve as the lead regulatory agency for remediation of this tank under the CERCLA process. At the time this unit was identified as a CERCLA site under the Tri-Party Agreement, it was placed within the 200-ZP-2 Operable Unit. In 1997, The Tri-parties redefined 200 Area Operable Units into waste groupings (Waste Site Grouping for 200 Areas Soils Investigations [DOE-RL 1992 and 1997]). A waste group contains waste sites that share similarities in geological conditions, function, and types of waste received. Tank 241-Z-361 is identified within the CERCLA Plutonium/Organic-rich Process Condensate/Process Waste Group (DOE-RL 1992). The Plutonium/Organic-rich Process Condensate/Process Waste Group has been prioritized for remediation beginning in the year 2004. Results of Tank 216-Z-361 sampling and analysis described in this Sampling and Analysis Plan (SAP) and in the SAP for sludge sampling (to be developed) will determine whether expedited response actions are required before 2004 because of the hazards associated with tank contents. Should data conclude that remediation of this tank should occur earlier than is planned for the other sites in the waste group, it is likely that removal alternatives will be analyzed in a separate Engineering Evaluation/Cost Analysis (EE/CA). Removal actions would proceed after the U.S. Environmental Protection Agency (EPA) signs an Action Memorandum describing the selected removal alternative for Tank 216-Z-361. If the data conclude that there is no immediate threat to human health and the environment from this tank, remedial actions for the tank will be defined in a

  3. Transportable aerosol sampling station with fixed volume (15 l) DMPA-15

    International Nuclear Information System (INIS)

    Giolu, G.; Guta, V.

    1999-01-01

    The mobile installation is used for air-sampling operations with fixed intake volumes, to be analysed by laboratories of routine environmental air monitoring. The station consists of several units, installed on a two-wheel mobile carriage-type platform: - a double - diaphragm pump (ensuring oil separation) that provides air intake and its evacuation to the air-analysers. The sampling and control unit has the following functions: - intake ensured by the pump that aspirates fixed volumes of air from the ambient atmosphere and feeding with it an inflatable rubber chamber. Air intake is automatically stopped as the cushion is filled up completely. A separation clamp is provided to seal up the cushion; - exhaust - allows the residual air to be evacuated from the cushion, ensuring its 'self-cleaning'; - shut down, manually operated; - analyse, the aerosol containing sample is aspirated from the inflatable rubber chamber and evacuated through a flow regulator to the analyser; - stop, canceling any previous commands. A relay unit controls the pneumatic lines and a pressure relay provides automatic stop of air intake process. The following technical features are given: - The fixed air volume in the chamber, 15 l - the air flow at the exit from the flow-meter, 0 - 15 l/min; - power requirements, 220 V/ 50 Hz; - power consumption, max. 1,5 kW; - overall dimensions, 460 x 500 x 820 mm; - weight, 53 kg. (authors)

  4. Evaluation of mycological contamination of dental unit waterlines.

    Science.gov (United States)

    Szymańska, Jolanta

    2005-01-01

    The quality of dental unit water is of great importance since patients and dental staff are regularly exposed to water from aerosols generated during work. The main purpose of this investigation was mycological evaluation of dental unit waterlines (DUWL). The author determined the number and species of fungi present in the water from a unit reservoir which is the source of water for a dental unit, in the water flowing from a high-speed handpiece of a unit, and in the swab sample collected from the wall of a waterline connecting a unit reservoir and dental handpieces. The following mould fungi were identified: Aspergillus amstelodami, Aspergillus fumigatus, Aspergillus spp. from Aspergillus glaucus group, Aspergillus repens, Citromyces spp., Geotrichum candidum, Penicillium aspergilliforme, Penicillium pusillum, Penicillium turolense, Sclerotium sclerotiorum; yeast-like fungi: Candida albicans, Candida curvata and other yeasts. Some of them, in certain circumstances, especially in people with immunological disorders, may be a cause of opportunistic infections. Thus, it is necessary that the DUWL should be submitted to a decontamination protocol and to routine microbial monitoring to guarantee an appropriate quality of water used in dental treatment.

  5. 200-BP-5 operable unit Technical Baseline report

    International Nuclear Information System (INIS)

    Jacques, I.D.; Kent, S.K.

    1991-10-01

    This report supports development of a remedial investigation/feasibility study work plan for the 200-BP-5 operable unit. The report summarizes baseline information for waste sites and unplanned release sites located in the 200-BP-5 operable unit. The sites were investigated by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (Westinghouse Hanford). The investigation consisted of review and evaluation of current and historical Hanford Site reports, drawings, and photographs, and was supplemented with recent inspections of the Hanford Site and employee interviews. No field investigations or sampling were conducted

  6. Crosshole investigations - physical properties of core samples from boreholes F1 and F2

    International Nuclear Information System (INIS)

    Magnusson, K.A.; Carlsten, S.; Olsson, O.

    1987-06-01

    The geology and physical properties have been studied of roughly 100 core samples from the boreholes F1 and F2 drilled at the Crosshole site, located at the 360 m level in the Stripa mine. The granitic rock has been divided into two classes: Fracture zones (also called major units) and a rock mass which is relatively undeformed. Samples from the major units have lower resistivity, higher porosity and dielectric constant than the samples from the less deformed rock mass. The electrical properties of the core samples have been measured over a frequency interval ranging from 1 Hz to 70 MHz. The conductivity of the samples increases with frequency, approximately with the frequency raised to the power 0.38. The dielectric constant decreases with frequency but is essentially constant above 3 MHz. These results show that the Hanai-Bruggeman equation can be used to describe the electrical bulk properties of the Stripa granite. The electrical conductivity of the samples is well correlated to the water content of the samples. The granite has a small contents of electrically conductive minerals which could influence the electrical bulk properties. (orig.)

  7. Effects of systematic sampling on satellite estimates of deforestation rates

    International Nuclear Information System (INIS)

    Steininger, M K; Godoy, F; Harper, G

    2009-01-01

    Options for satellite monitoring of deforestation rates over large areas include the use of sampling. Sampling may reduce the cost of monitoring but is also a source of error in estimates of areas and rates. A common sampling approach is systematic sampling, in which sample units of a constant size are distributed in some regular manner, such as a grid. The proposed approach for the 2010 Forest Resources Assessment (FRA) of the UN Food and Agriculture Organization (FAO) is a systematic sample of 10 km wide squares at every 1 deg. intersection of latitude and longitude. We assessed the outcome of this and other systematic samples for estimating deforestation at national, sub-national and continental levels. The study is based on digital data on deforestation patterns for the five Amazonian countries outside Brazil plus the Brazilian Amazon. We tested these schemes by varying sample-unit size and frequency. We calculated two estimates of sampling error. First we calculated the standard errors, based on the size, variance and covariance of the samples, and from this calculated the 95% confidence intervals (CI). Second, we calculated the actual errors, based on the difference between the sample-based estimates and the estimates from the full-coverage maps. At the continental level, the 1 deg., 10 km scheme had a CI of 21% and an actual error of 8%. At the national level, this scheme had CIs of 126% for Ecuador and up to 67% for other countries. At this level, increasing sampling density to every 0.25 deg. produced a CI of 32% for Ecuador and CIs of up to 25% for other countries, with only Brazil having a CI of less than 10%. Actual errors were within the limits of the CIs in all but two of the 56 cases. Actual errors were half or less of the CIs in all but eight of these cases. These results indicate that the FRA 2010 should have CIs of smaller than or close to 10% at the continental level. However, systematic sampling at the national level yields large CIs unless the

  8. Phase 2 Sampling Plan for Chestnut Ridge Operable Unit 2 (Filled Coal Ash Pond/Upper McCoy Branch) at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1992-08-01

    CDM Federal Programs Corporation (CDM Federal) was contracted by Martin Marietta Energy Systems, Inc. to prepare a Phase H Sampling Plan to describe field investigation work necessary to address regulatory agency review comments on the Remedial Investigation of Filled Coal Ash Pond (FCAP)/Upper McCoy Branch, Chestnut Ridge Operable Unit 2 at the Y-12 Plant, conducted by CH2M Hill in 1990. The scope and approach of the field investigation described in this plan specifically focus on deficiencies noted by the regulators in discussions at the comment resolution meeting of May 8, 1992, in Oak Ridge, Tennessee. This Phase II Sampling Plan includes a field sampling plan, a field and laboratory quality assurance project plan, a health and safety plan, a waste management plan, and appendixes providing an update to applicable or relevant and appropriate requirements for this site and field and laboratory testing methods and procedures. To address deficiencies noted by the regulators, the following activities will be conducted: Background surface soil and surface water/sediment samples will be collected based on statistical considerations for comparison to site data. Existing and new data to be collected will be used to support a human health risk assessment that includes the future homesteader scenario. Biological surveys, samples, and measurements will be collected/conducted to augment existing data and support an ecological risk assessment. Another round of groundwater sampling will be conducted, including on-site wells and the wells on Chestnut Ridge downgradient of the Security Pits. Borings will be completed in the FCAP to collect samples from below the surface depth to describe the chemical characteristics and volume of the ash. The volume of ash associated with sluice channel on Chestnut Ridge will be determined. Soil samples will be corrected below the coal ash in the FCAP and adjacent to sluice channel to evaluate soil contamination and migration of contaminants

  9. Frequency of Cannabis Use and Medical Cannabis Use Among Persons Living With HIV in the United States: Findings From a Nationally Representative Sample.

    Science.gov (United States)

    Pacek, Lauren R; Towe, Sheri L; Hobkirk, Andrea L; Nash, Denis; Goodwin, Renee D

    2018-04-01

    Little is known about cannabis use frequency, medical cannabis use, or correlates of use among persons living with HIV (PLWH) in United States nationally representative samples. Data came from 626 PLWH from the 2005-2015 National Survey on Drug Use and Health. Logistic regression identified characteristics associated with frequency of cannabis use. Chi-squares identified characteristics associated with medial cannabis use. Non-daily and daily cannabis use was reported by 26.9% and 8.0%. Greater perceived risk of cannabis use was negatively associated with daily and non-daily use. Younger age, substance use, and binge drinking were positively associated with non-daily cannabis use. Smoking and depression were associated with non-daily and daily use. One-quarter reported medical cannabis use. Medical users were more likely to be White, married, and nondrinkers. Cannabis use was common among PLWH. Findings help to differentiate between cannabis users based on frequency of use and medical versus recreational use.

  10. Ischemic Optic Neuropathy in Cardiac Surgery: Incidence and Risk Factors in the United States from the National Inpatient Sample 1998 to 2013.

    Science.gov (United States)

    Rubin, Daniel S; Matsumoto, Monica M; Moss, Heather E; Joslin, Charlotte E; Tung, Avery; Roth, Steven

    2017-05-01

    Ischemic optic neuropathy is the most common form of perioperative visual loss, with highest incidence in cardiac and spinal fusion surgery. To date, potential risk factors have been identified in cardiac surgery by only small, single-institution studies. To determine the preoperative risk factors for ischemic optic neuropathy, the authors used the National Inpatient Sample, a database of inpatient discharges for nonfederal hospitals in the United States. Adults aged 18 yr or older admitted for coronary artery bypass grafting, heart valve repair or replacement surgery, or left ventricular assist device insertion in National Inpatient Sample from 1998 to 2013 were included. Risk of ischemic optic neuropathy was evaluated by multivariable logistic regression. A total of 5,559,395 discharges met inclusion criteria with 794 (0.014%) cases of ischemic optic neuropathy. The average yearly incidence was 1.43 of 10,000 cardiac procedures, with no change during the study period (P = 0.57). Conditions increasing risk were carotid artery stenosis (odds ratio, 2.70), stroke (odds ratio, 3.43), diabetic retinopathy (odds ratio, 3.83), hypertensive retinopathy (odds ratio, 30.09), macular degeneration (odds ratio, 4.50), glaucoma (odds ratio, 2.68), and cataract (odds ratio, 5.62). Female sex (odds ratio, 0.59) and uncomplicated diabetes mellitus type 2 (odds ratio, 0.51) decreased risk. The incidence of ischemic optic neuropathy in cardiac surgery did not change during the study period. Development of ischemic optic neuropathy after cardiac surgery is associated with carotid artery stenosis, stroke, and degenerative eye conditions.

  11. BioSAXS Sample Changer: a robotic sample changer for rapid and reliable high-throughput X-ray solution scattering experiments.

    Science.gov (United States)

    Round, Adam; Felisaz, Franck; Fodinger, Lukas; Gobbo, Alexandre; Huet, Julien; Villard, Cyril; Blanchet, Clement E; Pernot, Petra; McSweeney, Sean; Roessle, Manfred; Svergun, Dmitri I; Cipriani, Florent

    2015-01-01

    Small-angle X-ray scattering (SAXS) of macromolecules in solution is in increasing demand by an ever more diverse research community, both academic and industrial. To better serve user needs, and to allow automated and high-throughput operation, a sample changer (BioSAXS Sample Changer) that is able to perform unattended measurements of up to several hundred samples per day has been developed. The Sample Changer is able to handle and expose sample volumes of down to 5 µl with a measurement/cleaning cycle of under 1 min. The samples are stored in standard 96-well plates and the data are collected in a vacuum-mounted capillary with automated positioning of the solution in the X-ray beam. Fast and efficient capillary cleaning avoids cross-contamination and ensures reproducibility of the measurements. Independent temperature control for the well storage and for the measurement capillary allows the samples to be kept cool while still collecting data at physiological temperatures. The Sample Changer has been installed at three major third-generation synchrotrons: on the BM29 beamline at the European Synchrotron Radiation Facility (ESRF), the P12 beamline at the PETRA-III synchrotron (EMBL@PETRA-III) and the I22/B21 beamlines at Diamond Light Source, with the latter being the first commercial unit supplied by Bruker ASC.

  12. Comparison of Sample and Detection Quantification Methods for Salmonella Enterica from Produce

    Science.gov (United States)

    Hummerick, M. P.; Khodadad, C.; Richards, J. T.; Dixit, A.; Spencer, L. M.; Larson, B.; Parrish, C., II; Birmele, M.; Wheeler, Raymond

    2014-01-01

    The purpose of this study was to identify and optimize fast and reliable sampling and detection methods for the identification of pathogens that may be present on produce grown in small vegetable production units on the International Space Station (ISS), thus a field setting. Microbiological testing is necessary before astronauts are allowed to consume produce grown on ISS where currently there are two vegetable production units deployed, Lada and Veggie.

  13. Antibodies against MERS coronavirus in dromedary camels, United Arab Emirates, 2003 and 2013.

    Science.gov (United States)

    Meyer, Benjamin; Müller, Marcel A; Corman, Victor M; Reusken, Chantal B E M; Ritz, Daniel; Godeke, Gert-Jan; Lattwein, Erik; Kallies, Stephan; Siemens, Artem; van Beek, Janko; Drexler, Jan F; Muth, Doreen; Bosch, Berend-Jan; Wernery, Ulrich; Koopmans, Marion P G; Wernery, Renate; Drosten, Christian

    2014-04-01

    Middle East respiratory syndrome coronavirus (MERS-CoV) has caused an ongoing outbreak of severe acute respiratory tract infection in humans in the Arabian Peninsula since 2012. Dromedary camels have been implicated as possible viral reservoirs. We used serologic assays to analyze 651 dromedary camel serum samples from the United Arab Emirates; 151 of 651 samples were obtained in 2003, well before onset of the current epidemic, and 500 serum samples were obtained in 2013. Recombinant spike protein-specific immunofluorescence and virus neutralization tests enabled clear discrimination between MERS-CoV and bovine CoV infections. Most (632/651, 97.1%) camels had antibodies against MERS-CoV. This result included all 151 serum samples obtained in 2003. Most (389/651, 59.8%) serum samples had MERS-CoV-neutralizing antibody titers >1,280. Dromedary camels from the United Arab Emirates were infected at high rates with MERS-CoV or a closely related, probably conspecific, virus long before the first human MERS cases.

  14. The capital asset pricing model versus the three factor model: A United Kingdom Perspective

    Directory of Open Access Journals (Sweden)

    Chandra Shekhar Bhatnagar

    2013-07-01

    Full Text Available The Sharpe (1964, Lintner (1965 and Black (1972 Capital Asset Pricing Model (CAPM postulates that the equilibrium rates of return on all risky assets are a linear function of their covariance with the market portfolio. Recent work by Fama and French (1996, 2006 introduce a Three Factor Model that questions the “real world application” of the CAPM Theorem and its ability to explain stock returns as well as value premium effects in the United States market. This paper provides an out-of-sample perspective to the work of Fama and French (1996, 2006. Multiple regression is used to compare the performance of the CAPM, a split sample CAPM and the Three Factor Model in explaining observed stock returns and value premium effects in the United Kingdom market. The methodology of Fama and French (2006 was used as the framework for this study. The findings show that the Three Factor Model holds for the United Kingdom Market and is superior to the CAPM and the split sample CAPM in explaining both stock returns and value premium effects. The “real world application” of the CAPM is therefore not supported by the United Kingdom data.

  15. Occupational therapy students' attitudes towards inclusion education in Australia, United Kingdom, United States and Taiwan.

    Science.gov (United States)

    Mu, Keli; Brown, Ted; Peyton, Claudia G; Rodger, Sylvia; Huang, Yan-Hua; Wu, Chin-Yu; Watson, Callie; Stagnitti, Karen; Hutton, Eve; Casey, Jackie; Hong, Chia Swee

    2010-03-01

    This international, cross-cultural study investigated the attitudes of occupational therapy students from Australia, United Kingdom, United States and Taiwan towards inclusive education for students with disabilities. The possible impact of professional education on students' attitudes was also explored. A total of 485 students from 11 entry-level occupational therapy education programmes from Australia, the United Kingdom, the United States and Taiwan participated in the study. Among them, 264 were freshmen (first-year students) and 221 were seniors (final-year students). Data collected from a custom-designed questionnaire were analysed both quantitatively and qualitatively. In general, the occupational therapy students reported having positive attitudes towards inclusion. Considerable differences, however, existed among the student groups from the four countries. Professional education appeared to have a significant impact on students' attitudes towards inclusion from first year to senior year. Although students were in favour of inclusion, they also cautioned that their support for inclusive practices depended on various factors such as adequate preparation, support and assistance to students with disabilities. Limitations of the study included the small, convenience sample and different degree structures of the participating programmes. Future research studies need to compare occupational therapy students' attitudes with students from other health care professions. A longitudinal study on the impact of the professional education programme on students' attitudes towards inclusive education is warranted.

  16. Sampling and analysis methods for geothermal fluids and gases

    Energy Technology Data Exchange (ETDEWEB)

    Shannon, D. W.

    1978-01-01

    The data obtained for the first round robin sample collected at Mesa 6-2 wellhead, East Mesa Test Site, Imperial Valley are summarized. Test results are listed by method used for cross reference to the analytic methods section. Results obtained for radioactive isotopes present in the brine sample are tabulated. The data obtained for the second round robin sample collected from the Woolsey No. 1 first stage flash unit, San Diego Gas and Electric Niland Test Facility are presented in the same manner. Lists of the participants of the two round robins are given. Data from miscellaneous analyses are included. Summaries of values derived from the round robin raw data are presented. (MHR)

  17. Prospective Associations between Religiousness/Spirituality and Depression and Mediating Effects of Forgiveness in a Nationally Representative Sample of United States Adults.

    Science.gov (United States)

    Toussaint, Loren L; Marschall, Justin C; Williams, David R

    2012-01-01

    The present investigation examines the prospective associations of religiousness/spirituality with depression and the extent to which various dimensions of forgiveness act as mediating mechanisms of these associations. Data are from a nationally representative sample of United States adults who were first interviewed in 1998 and reinterviewed six months later. Measures of religiousness/spirituality, forgiveness, and various sociodemographics were collected. Depression was assessed using the Composite International Diagnostic Interview administered by trained interviewers. Results showed that religiousness/spirituality, forgiveness of oneself and others, and feeling forgiven by God were associated, both cross-sectionally and longitudinally, with depressive status. After controlling for initial depressive status, only forgiveness of oneself and others remained statistically significant predictors of depression. Path analyses revealed that religiousness/spirituality conveyed protective effects, prospectively, on depression by way of an indirect path through forgiveness of others but not forgiveness of oneself. Hence, forgiveness of others acts as a mechanism of the salutary effect of religiousness/spirituality, but forgiveness of oneself is an independent predictor. Conclusions regarding the continued development of this type of research and for the treatment of clients with depression are offered.

  18. Transuranic Storage Area (TSA)-3 container storage unit RCRA closure plan

    International Nuclear Information System (INIS)

    Barry, G.A.; Lodman, D.L.; Spry, M.J.; Poor, K.J.

    1992-11-01

    This document describes the proposed plan for closure of the Transuranic Storage Area (TSA)-3 container storage unit at the Idaho National Engineering Laboratory in accordance with the Resource Conservation and Recovery Act closure requirements. The location, size, capacity, history, and current status of the unit are described. The unit will be closed by decontaminating structures and equipment that may have contacted waste. Sufficient sampling and documentation of all activities will be performed to demonstrate clean closure. A tentative schedule is provided in the form of a milestone chart

  19. The Economics of an Admissions Holding Unit.

    Science.gov (United States)

    Schreyer, Kraftin E; Martin, Richard

    2017-06-01

    With increasing attention to the actual cost of delivering care, return-on-investment calculations take on new significance. Boarded patients in the emergency department (ED) are harmful to clinical care and have significant financial opportunity costs. We hypothesize that investment in an admissions holding unit for admitted ED patients not only captures opportunity cost but also significantly lowers direct cost of care. This was a three-phase study at a busy urban teaching center with significant walkout rate. We first determined the true cost of maintaining a staffed ED bed for one patient-hour and compared it to alternative settings. The opportunity cost for patients leaving without being seen was then conservatively estimated. Lastly, a convenience sample of admitted patients boarding in the ED was observed continuously from one hour after decision-to-admit until physical departure from the ED to capture a record of every interaction with a nurse or physician. Personnel costs per patient bed-hour were $58.20 for the ED, $24.80 for an inpatient floor, $19.20 for the inpatient observation unit, and $10.40 for an admissions holding area. An eight-bed holding unit operating at practical capacity would free 57.4 hours of bed space in the ED and allow treatment of 20 additional patients. This could yield increased revenues of $27,796 per day and capture opportunity cost of $6.09 million over 219 days, in return for extra staffing costs of $218,650. Analysis of resources used for boarded patients was determined by continuous observation of a convenience sample of ED-boarded patients, which found near-zero interactions with both nursing and physicians during the boarding interval. Resource expense per ED bed-hour is more than twice that in non-critical care inpatient units. Despite the high cost of available resources, boarded non-critical patients receive virtually no nursing or physician attention. An admissions holding unit is remarkably effective in avoiding the

  20. The Economics of an Admissions Holding Unit

    Directory of Open Access Journals (Sweden)

    Kraftin E. Schreyer

    2017-05-01

    Full Text Available Introduction: With increasing attention to the actual cost of delivering care, return-on-investment calculations take on new significance. Boarded patients in the emergency department (ED are harmful to clinical care and have significant financial opportunity costs. We hypothesize that investment in an admissions holding unit for admitted ED patients not only captures opportunity cost but also significantly lowers direct cost of care. Methods: This was a three-phase study at a busy urban teaching center with significant walkout rate. We first determined the true cost of maintaining a staffed ED bed for one patient-hour and compared it to alternative settings. The opportunity cost for patients leaving without being seen was then conservatively estimated. Lastly, a convenience sample of admitted patients boarding in the ED was observed continuously from one hour after decision-to-admit until physical departure from the ED to capture a record of every interaction with a nurse or physician. Results: Personnel costs per patient bed-hour were $58.20 for the ED, $24.80 for an inpatient floor, $19.20 for the inpatient observation unit, and $10.40 for an admissions holding area. An eight-bed holding unit operating at practical capacity would free 57.4 hours of bed space in the ED and allow treatment of 20 additional patients. This could yield increased revenues of $27,796 per day and capture opportunity cost of $6.09 million over 219 days, in return for extra staffing costs of $218,650. Analysis of resources used for boarded patients was determined by continuous observation of a convenience sample of ED-boarded patients, which found near-zero interactions with both nursing and physicians during the boarding interval. Conclusion: Resource expense per ED bed-hour is more than twice that in non-critical care inpatient units. Despite the high cost of available resources, boarded non-critical patients receive virtually no nursing or physician attention. An

  1. Observations of radiation fog chemistry in the Eastern United States

    Science.gov (United States)

    Straub, D.; Hutchings, J.; Herckes, P.

    2010-07-01

    The chemical composition of radiation fog in the Mid-Atlantic region of the United States has been the focus of an ongoing field campaign based in Selinsgrove, PA. This field study was established to provide a long term record that can be used to identify the effects of meteorology and air mass source regions on fog composition and to shed light on the role that fog can play in the production of secondary inorganic and organic aerosol mass. In the United States, studies that focus on radiation fog have been relatively rare. For the most part, they have been limited geographically to the Central Valley of California, though individual studies have also been conducted in the Central United States and along the Texas-Louisiana Gulf Coast. Sample collection for the current study began during the fall of 2007. Through 2009, samples from 25 radiation fog events have been obtained. A Caltech Heated Rod Cloudwater Collector (CHRCC) having a Dp50 of approximately 8 microns was used to collect one fog sample per event. Samples were typically collected between 2:00 AM and 7:00 AM under conditions of light winds, clear skies, and recent rainfall. Sample volumes ranged from 2.9 ml to 150 ml. Following collection, samples were analyzed for pH and then one of the following: major inorganic ions, dissolved total organic carbon, N-nitrosodimethylamine (NDMA), metals, or organic speciation. Through 2009, sample pH varied between 4.28 and 6.86 and averaged 5.03 based on H+ concentration. Ammonium and sulfate were found to be the most abundant ionic species in the fog samples. Sufficient ammonium was detected in nearly every sample to fully neutralize nitrate and sulfate. The concentrations of sulfate, nitrate, and ammonium observed in this study were lower than values reported in the literature for most other cloud and fog studies conducted in the US. Due to significant ammonium input, pH in the current study was higher than most other studies. Concentrations of total organic carbon

  2. Atmospheric aerosol studies using the 'Gent' stacked filter unit and other aerosol collectors, with multi-elemental analysis of the samples by nuclear-related analytical techniques. Appendix 4

    International Nuclear Information System (INIS)

    Maenhaut, Willy; Francois, Filip; Cafmeyer, Jan; Okunade, Olusola

    1995-01-01

    Our research within the core programme of the Co-ordinated Research Programme (CRP) on Air Pollution is described. This included the analysis of the analytical quality control Nuclepore filter samples, work on the calibration of the PM10 inlet of the 'Gent' stacked filter unit (SFU) sampler, and an aerosol study with this SFU sampler at an urban residential site in Gent. The calibration of the Gent PM10 inlet was done through intercomparisons with commercially available PM10 samplers, and quite reasonable agreement was obtained. For the study at the urban residential site, a total of 118 SFU samples were collected. The samples were analyzed for the particulate mass, black carbon and up to 29 elements. The elements were measured by PIXE and short-irradiation INAA. Median atmospheric concentrations and enrichment factors were calculated for the fine and coarse size fractions, and average FINE/COARSE ratios were derived. The median concentrations were compared with those from a study, done at the same site in the fall of 1986. The levels of the automotive elements Pb and Br had decreased by a factor of about three relative to 1986, but most other elements exhibited very similar concentrations. A brief overview is given of the status in our various regional and global scale aerosol studies. Finally, our plans for future work are given. (author)

  3. 200-BP-11 operable unit and 216-B-3 main pond work/closure plan, Hanford Site, Richland, Washington. Volume 1: Field investigation and sampling strategy

    International Nuclear Information System (INIS)

    1994-09-01

    This document coordinates a Resource Conservation and Recovery Act (RCRA) past-practice work plan for the 200-BP-11 Operable Unit and a RCRA closure/postclosure plan for the 216-B-3 Main Pond and 216-B-3-3 Ditch [treatment, storage, and/or disposal (TSD) unit]. Both RCRA TSD and past-practice waste management units are contained within the 200-BP-11 Operable Unit. The 200-BP-11 Operable Unit is a source operable unit located on the east side of the B Plant Source Aggregate Area in the 200 East Area of the Hanford Site. The operable unit lies just east of the 200 East Area perimeter fence and encompass approximately 476 hectares (1,175 acres). Source operable units include waste management units that are potential sources of radioactive and/or hazardous substance contamination. Source waste management units are categorized in the Hanford Federal Facility Agreement and Consent Order as either RCRA TSD, RCRA past-practice, or Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) past-practice. As listed below and in the Tri-Party Agreement, the 200-BP-11 Operable Unit contains five RCRA past-practice and five RCRA TSD waste management units. Additionally, for RCRA TSD permitting purposes, the RCRA TSD waste management units are subdivided into two RCRA TSD units

  4. Methods for Sampling and Measurement of Compressed Air Contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Stroem, L

    1976-10-15

    In order to improve the technique for measuring oil and water entrained in a compressed air stream, a laboratory study has been made of some methods for sampling and measurement. For this purpose water or oil as artificial contaminants were injected in thin streams into a test loop, carrying dry compressed air. Sampling was performed in a vertical run, down-stream of the injection point. Wall attached liquid, coarse droplet flow, and fine droplet flow were sampled separately. The results were compared with two-phase flow theory and direct observation of liquid behaviour. In a study of sample transport through narrow tubes, it was observed that, below a certain liquid loading, the sample did not move, the liquid remaining stationary on the tubing wall. The basic analysis of the collected samples was made by gravimetric methods. Adsorption tubes were used with success to measure water vapour. A humidity meter with a sensor of the aluminium oxide type was found to be unreliable. Oil could be measured selectively by a flame ionization detector, the sample being pretreated in an evaporation- condensation unit

  5. Methods for Sampling and Measurement of Compressed Air Contaminants

    International Nuclear Information System (INIS)

    Stroem, L.

    1976-10-01

    In order to improve the technique for measuring oil and water entrained in a compressed air stream, a laboratory study has been made of some methods for sampling and measurement. For this purpose water or oil as artificial contaminants were injected in thin streams into a test loop, carrying dry compressed air. Sampling was performed in a vertical run, down-stream of the injection point. Wall attached liquid, coarse droplet flow, and fine droplet flow were sampled separately. The results were compared with two-phase flow theory and direct observation of liquid behaviour. In a study of sample transport through narrow tubes, it was observed that, below a certain liquid loading, the sample did not move, the liquid remaining stationary on the tubing wall. The basic analysis of the collected samples was made by gravimetric methods. Adsorption tubes were used with success to measure water vapour. A humidity meter with a sensor of the aluminium oxide type was found to be unreliable. Oil could be measured selectively by a flame ionization detector, the sample being pretreated in an evaporation- condensation unit

  6. Umbilical cord blood units for public storage donors screening for markers of infectious agents

    Directory of Open Access Journals (Sweden)

    A. B. Smolyaninov

    2012-01-01

    Full Text Available The screening of 3515 cord blood samples which had entered bank for public use for presence of markers of infectious agents was carried out. It was established that majority of cord blood units contain markers of cytomegalovirus and Toxoplasma (81% that is not a contraindication for storage and subsequent use of these samples. In 4.6% of cases umbilical cord blood units were subjected to disposal because of identification of viral hepatitis B and C, as well as Tr. pallidum markers, moreover, the largest share of the discarded units contained antibodies to HbscorAg – 71,3%. Inclusion of analysis on the presence of Anti-HBcor in the required laboratory screening of mothers-donors CB was proposed in order to reduce the percentage of discarded umbilical cord blood units for the public inventory.

  7. Limited field investigation report for the 100-HR-3 operable unit

    International Nuclear Information System (INIS)

    1994-09-01

    This limited field investigation (LFI) was conducted to assess the applicability of interim remedial measures (IRM) for reducing human health and environmental risks within the 100-HR-3 Groundwater Operable Unit. The 100-HR-3 Operable Unit is comprised of three subareas; the 100 D Area, the 100 H Area and those portions of the 600 Area between the two reactor areas. The operable unit is one of seven operable units associated with the 100 D and H Areas. Operable units 100-DR-1, 100-DR-2, 100-DR-3, 100-HR-1, 100-HR-2 and 100-IU-4 address contaminant sources while 100-HR-3 addresses contamination present in the underlying groundwater. The primary method of field investigation used during this LFI was the installation and sampling of monitoring wells. Samples were collected from the groundwater and soils, and submitted for laboratory analysis. Boreholes were surveyed for radiological contamination using downhole geophysical techniques to further delineate the locations and levels of contaminants. All samples were screened to ascertain the presence of volatile organic compounds and radionuclides. Analytical data were subjected to validation; all round one, two and three and a minimum of 10% of round four data associated with the LFI were validated. A screening method was used to identify contaminants of potential concern (COPC). This screening method eliminated from further consideration, constituents that were below background. Constituents which are considered non-toxic to humans were eliminated from the human health evaluation. Data consistency and blank contamination were also evaluated in the screening process. These COPC were then evaluated further in the qualitative risk assessment (QRA). A human health QRA was performed using conservative (maximum equilibrated contaminant levels from the LFI) analyses

  8. Assessment of land use change in the coterminous United States and Alaska for global assessment of forest loss conducted by the food and agricultural organization of the United Nations

    Science.gov (United States)

    Tanushree Biswas; Mike Walterman; Paul Maus; Kevin A. Megown; Sean P. Healey; Kenneth Brewer

    2012-01-01

    The Food and Agricultural Organization (FAO) of the United Nations conducted a global assessment for forest change in 2010 using satellite imagery from 1990, 2000, and 2005. The U.S. Forest Service was responsible for assessing forest change in the United States. A polygon-based, stratified sampling design developed by FAO was used to assess change in forest area...

  9. The distribution of selected elements and minerals in soil of the conterminous United States

    Science.gov (United States)

    Woodruff, Laurel G.; Cannon, William F.; Smith, David; Solano, Federico

    2015-01-01

    In 2007, the U.S. Geological Survey initiated a low-density (1 site per 1600 km2, 4857 sites) geochemical and mineralogical survey of soil of the conterminous United States as part of the North American Soil Geochemical Landscapes Project. Three soil samples were collected, if possible, from each site; (1) a sample from a depth of 0 to 5 cm, (2) a composite of the soil A-horizon, and (3) a deeper sample from the soil C-horizon or, if the top of the C-horizon was at a depth greater than 100 cm, from a depth of approximately 80–100 cm. The The major mineralogical components in samples from the soil A- and C-horizons were determined by a quantitative X-ray diffraction method using Rietveld refinement. Sampling ended in 2010 and chemical and mineralogical analyses were completed in May 2013. Maps of the conterminous United States showing predicted element and mineral concentrations were interpolated from actual soil data for each soil sample type by an inverse distance weighted (IDW) technique using ArcGIS software. Regional- and national-scale map patterns for selected elements and minerals apparent in interpolated maps are described here in the context of soil-forming factors and possible human inputs. These patterns can be related to (1) soil parent materials, for example, in the distribution of quartz, (2) climate impacts, for example, in the distribution of feldspar and kaolinite, (3) soil age, for example, in the distribution of carbonate in young glacial deposits, and (4) possible anthropogenic loading of phosphorus (P) and lead (Pb) to surface soil. This new geochemical and mineralogical data set for the conterminous United States represents a major step forward from prior national-scale soil geochemistry data and provides a robust soil data framework for the United States now and into the future.

  10. Sampling pig farms at the abattoir in a cross-sectional study - Evaluation of a sampling method.

    Science.gov (United States)

    Birkegård, Anna Camilla; Halasa, Tariq; Toft, Nils

    2017-09-15

    A cross-sectional study design is relatively inexpensive, fast and easy to conduct when compared to other study designs. Careful planning is essential to obtaining a representative sample of the population, and the recommended approach is to use simple random sampling from an exhaustive list of units in the target population. This approach is rarely feasible in practice, and other sampling procedures must often be adopted. For example, when slaughter pigs are the target population, sampling the pigs on the slaughter line may be an alternative to on-site sampling at a list of farms. However, it is difficult to sample a large number of farms from an exact predefined list, due to the logistics and workflow of an abattoir. Therefore, it is necessary to have a systematic sampling procedure and to evaluate the obtained sample with respect to the study objective. We propose a method for 1) planning, 2) conducting, and 3) evaluating the representativeness and reproducibility of a cross-sectional study when simple random sampling is not possible. We used an example of a cross-sectional study with the aim of quantifying the association of antimicrobial resistance and antimicrobial consumption in Danish slaughter pigs. It was not possible to visit farms within the designated timeframe. Therefore, it was decided to use convenience sampling at the abattoir. Our approach was carried out in three steps: 1) planning: using data from meat inspection to plan at which abattoirs and how many farms to sample; 2) conducting: sampling was carried out at five abattoirs; 3) evaluation: representativeness was evaluated by comparing sampled and non-sampled farms, and the reproducibility of the study was assessed through simulated sampling based on meat inspection data from the period where the actual data collection was carried out. In the cross-sectional study samples were taken from 681 Danish pig farms, during five weeks from February to March 2015. The evaluation showed that the sampling

  11. Mission Statements of Christian Elementary Schools in the United States and the Netherlands

    Science.gov (United States)

    Zandstra, Anne M.

    2012-01-01

    This study compares the mission statements of a small sample of Christian elementary schools in the United States and the Netherlands. In the United States, Christian schools are private schools, while in the Netherlands Christian schools receive state funding, just like public schools. Content analysis of mission statements revealed similarities…

  12. Sampling scales define occupancy and underlying occupancy-abundance relationships in animals.

    Science.gov (United States)

    Steenweg, Robin; Hebblewhite, Mark; Whittington, Jesse; Lukacs, Paul; McKelvey, Kevin

    2018-01-01

    Occupancy-abundance (OA) relationships are a foundational ecological phenomenon and field of study, and occupancy models are increasingly used to track population trends and understand ecological interactions. However, these two fields of ecological inquiry remain largely isolated, despite growing appreciation of the importance of integration. For example, using occupancy models to infer trends in abundance is predicated on positive OA relationships. Many occupancy studies collect data that violate geographical closure assumptions due to the choice of sampling scales and application to mobile organisms, which may change how occupancy and abundance are related. Little research, however, has explored how different occupancy sampling designs affect OA relationships. We develop a conceptual framework for understanding how sampling scales affect the definition of occupancy for mobile organisms, which drives OA relationships. We explore how spatial and temporal sampling scales, and the choice of sampling unit (areal vs. point sampling), affect OA relationships. We develop predictions using simulations, and test them using empirical occupancy data from remote cameras on 11 medium-large mammals. Surprisingly, our simulations demonstrate that when using point sampling, OA relationships are unaffected by spatial sampling grain (i.e., cell size). In contrast, when using areal sampling (e.g., species atlas data), OA relationships are affected by spatial grain. Furthermore, OA relationships are also affected by temporal sampling scales, where the curvature of the OA relationship increases with temporal sampling duration. Our empirical results support these predictions, showing that at any given abundance, the spatial grain of point sampling does not affect occupancy estimates, but longer surveys do increase occupancy estimates. For rare species (low occupancy), estimates of occupancy will quickly increase with longer surveys, even while abundance remains constant. Our results

  13. Selecting a sampling method to aid in vegetation management decisions in loblolly pine plantations

    Science.gov (United States)

    David R. Weise; Glenn R. Glover

    1993-01-01

    Objective methods to evaluate hardwood competition in young loblolly pine (Pinustaeda L.) plantations are not widely used in the southeastern United States. Ability of common sampling rules to accurately estimate hardwood rootstock attributes at low sampling intensities and across varying rootstock spatial distributions is unknown. Fixed area plot...

  14. The development of neutron activation, sample transportation and γ-ray counting routine system for numbers of geological samples

    International Nuclear Information System (INIS)

    Shibata Shin-nosuke; Tanaka, Tsuyoshi; Minami, Masayo

    2001-01-01

    A new gamma-ray counting and data processing system for non-destructive neutron activation analysis has been set up in Radioisotope Center in Nagoya University. The system carry out gamma-ray counting, sample change and data processing automatically, and is able to keep us away from parts of complicated operations in INAA. In this study, we have arranged simple analytical procedure that makes practical works easier than previous. The concrete flow is described from the reparation of powder rock samples to gamma-ray counting and data processing by the new INAA system. Then it is run over that the analyses used two Geological Survey of Japan rock reference samples JB-1a and JG-1a in order to evaluate how the new analytical procedure give any speediness and accuracy for analyses of geological materials. Two United States Geological Survey reference samples BCR-1 and G-2 used as the standard respectively. Twenty two elements for JB-1a and 25 elements for JG-1a were analyzed, the uncertainty are <5% for Na, Sc, Fe, Co, La, Ce, Sm, Eu, Yb, Lu, Hf, Ta and Th, and of <10% for Cr, Zn, Cs, Ba, Nd, Tb and U. This system will enable us to analyze more than 1500 geologic samples per year. (author)

  15. Suggestions for a competency-based orientation for an orthopaedic unit.

    Science.gov (United States)

    Bryant, G A

    1997-01-01

    Effective orientation programs should provide new RN and LPN employees with very specific performance expectations. Competency-based orientation provides such a structure. This approach not only decreases the orientee's anxiety, but it also acts as a basis for establishing competencies specific to that unit. Because the existing staff members are intimately involved in the process, socialization within the unit and cohesiveness of purpose are enhanced. Adult learning theory, educational principles, self-paced learning modules, and the use of preceptors and check-off lists are employed in this Competency-Based Orientation (CBO) program for an adult orthopaedic unit. Samples of various aspects of a CBO are included.

  16. Calculation of upper confidence bounds on not-sampled vegetation types using a systematic grid sample: An application to map unit definition for existing vegetation maps

    Science.gov (United States)

    Paul L. Patterson; Mark Finco

    2009-01-01

    This paper explores the information FIA data can produce regarding forest types that were not sampled and develops the equations necessary to define the upper confidence bounds on not-sampled forest types. The problem is reduced to a Bernoulli variable. This simplification allows the upper confidence bounds to be calculated based on Cochran (1977). Examples are...

  17. Variabilidade horizontal da fertilidade do solo de uma unidade de amostragem em sistema plantio direto Horizontal variability of soil fertility in a sampling unit under no-till system

    Directory of Open Access Journals (Sweden)

    V. H. Alvarez V.

    2003-04-01

    com pá de corte. A variabilidade foi baixa para pH, P-rem e H + Al e alta para P, Al3+, Mg2+, K e Ca2+. Dez amostras simples coletadas com pá de corte ou 27 amostras simples coletadas de forma localizada com trado de caneca (cinco amostras coletadas no sulco de plantio, nove coletadas a 10 cm do sulco e 13 coletadas no ponto médio entre sulcos foram necessárias à formação de amostras compostas representativas. As análises das amostras compostas, tanto de pá de corte quanto de trado, apresentaram valores semelhantes às médias das análises das respectivas amostras simples, caracterizando corretamente a fertilidade média da unidade de amostragem.Sampling soil with the auger hole is simpler and faster than with the cutting shovel. The last is frequently used in no till systems to obtain soil samples for fertility analyses. This study had the following objectives: comparison of two different localized soil sampling systems concerning the horizontal variability of chemical soil characteristics; determination of the necessary unit number to compose a representative sample of the area, and the demonstration that mean fertility values obtained from the composite sample are the same as the obtained from the arithmetic mean of single samplings. The study was carried out in an area under no till system since 15 years. The localized sampling systems were: cutting shovel (24 single samples collected perpendicularly to the furrow and in the middle of the space between two furrows and auger hole (20 single samples collected in the planting furrow (Ts, 20 single samples collected 10 cm beside the furrow (T10, and 20 single samples collected 40 cm beside the furrow (T40.Representative sub-samples of both methods were randomly chosen from the single ones, and mixed to make up respective composite samples. P, K, Ca2+, Mg2+, and Al3+, and the values of pH, H + Al, and P-rem were determined in the single and composite samples, and their means, standard deviation, and variation

  18. Plasma as alternatively sample to quantify tetanus antitoxin

    Directory of Open Access Journals (Sweden)

    Ariel Menéndez-Barrios

    2015-08-01

    Full Text Available Tetanus antitoxin is quantified in Cuba at blood banks, from the serum of immunized donors, to produce aspecific human gamma globulin. A heterogeneous indirect immunoenzymatic assay is used, using the serum as analytical sample. The possible use of plasma obtained from plasmapheresis as alternative sample was evaluated in this research, to minimize the volume of total blood extracted to the donors. One hundred plasma donors who came to donate between October and November 2013 were selected by simple random sampling. Serum sample was obtained for extraction of 5 mL of blood, deposited in dry glass tube. While the other sample took 1.5 mL of plasma in a plastic tube with cover, at the end of the donation directly of the unit of plasma collected. Comparison of the difference between the means of both groups was done using SPSS for Windows. It was found that the values obtained in serum were bigger than those obtained in plasma. Difference between the means of both groups was statistically significant (p 0.00. It is not advisable to use the obtained plasma of the plasmapheresis as analytic sample in this assay.

  19. Mare Crisium - Regional stratigraphy and geologic history. [from spectral reflectivities of Lunik 24 samples

    Science.gov (United States)

    Adams, J. B.; Head, J. W., III; Mccord, T. B.; Pieters, C.; Zisk, S.

    1978-01-01

    Spectral reflectance measurements of five Luna 24 samples and new telescopic reflectance spectra of 10-20 km areas of seven sites in Mare Crisium have been used to calibrate multispectral images of mare units. Based on these data, three major mare units are defined in the Crisium basin and their stratigraphy is interpreted. The oldest mare unit is exposed in the ejecta of the craters Picard and Peirce and along the outer edge of the southeastern part of the basin. The next younger unit includes the Luna 24 site and generally follows a topographic annulus along the basin margin. The youngest mare unit occupies the central part of the basin. It is concluded that subsidence occurred throughout the emplacement of mare units, including extensive warping and downfaulting of the inner part of the Crisium basin.

  20. SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-13-189, MCU-13-190, AND MCU-13-191: QUARTERLY SAMPLE FROM SEPTEMBER 2013

    Energy Technology Data Exchange (ETDEWEB)

    Fondeur, F.; Taylor-Pashow, K.

    2013-10-31

    Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-13-189, MCU-13-190, and MCU-13-191 received on September 4, 2013 are reported. The results show that the solvent (remaining heel in the SHT tank) at MCU contains excess Isopar L and a deficit concentration of modifier and trioctylamine when compared to the standard MCU solvent. As with the previous solvent sample results, these analyses indicate that the solvent does not require Isopar L trimming at this time. Since MCU is switching to NGS, there is no need to add TOA nor modifier. SRNL also analyzed the SHT sample for {{sup 137}Cs content and determined the measured value is within tolerance and the value has returned to levels observed in 2011.

  1. Analysis of polonium-210 in food samples

    International Nuclear Information System (INIS)

    Bueno, Luciana; Cunha, Ieda Irma Lamas

    1999-01-01

    This paper presents the polonium levels in food products. The analysis procedure consisted of acid leaching of the samples, solution evaporation, addition of hydrochloric acid, spontaneous deposition of polonium on a silver disk counting by alpha spectroscopy. The method was applied in reference materials and in foodstuffs, resulting in the following values: tea samples 0.4 to 1.7 Bq/unit; fish = 0.17 to 0.40 Bq/Kg, fruits = 0.048 to 0.067 Bq/kg, vegetables = 0.12 to 0.31 Bq/kg, cereal = 0.036 to 0.042 Bq/kg and legumes = 0.024 to 0.51 Bq/kg. The results are very important for public health due to the possible effects to the human organism by the ingestion of contaminated foodstuffs. (author)

  2. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2008

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2008-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by Pacific Northwest National Laboratory for the U.S. Department of Energy. Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 450.1, "Environmental Protection Program," and DOE Order 5400.5, "Radiation Protection of the Public and the Environment." The environmental surveillance sampling design is described in the "Hanford Site Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office." This document contains the calendar year 2008 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2008, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2008.

  3. Computerized nursing process in the Intensive Care Unit: ergonomics and usability

    OpenAIRE

    Almeida,Sônia Regina Wagner de; Sasso,Grace Teresinha Marcon Dal; Barra,Daniela Couto Carvalho

    2016-01-01

    Abstract OBJECTIVE Analyzing the ergonomics and usability criteria of the Computerized Nursing Process based on the International Classification for Nursing Practice in the Intensive Care Unit according to International Organization for Standardization(ISO). METHOD A quantitative, quasi-experimental, before-and-after study with a sample of 16 participants performed in an Intensive Care Unit. Data collection was performed through the application of five simulated clinical cases and an evalua...

  4. Assessment of the Microbiological Safety of Precut Fruit from Retail and Catering Premises in the United Kingdom.

    Science.gov (United States)

    Willis, Caroline; McLauchlin, Jim; Amar, Corinne; Sadler-Reeves, Lorraine; Elviss, Nicola; Aird, Heather; Fox, Andrew; Kaye, Moira

    2016-04-01

    Fresh fruit has been associated with a number of foodborne outbreaks in recent years. In particular, a large outbreak of listeriosis in the United States in 2011 was associated with consumption of cantaloupe melon, and an outbreak of Salmonella Newport in the United Kingdom and Europe (also in 2011) was linked to watermelon consumption. A study of precut fruit products from catering and retail premises in the United Kingdom was, therefore, carried out to assess their microbiological safety. Between January and March 2012, samples (1,188) of ready-to-eat precut fruit were collected from retail and catering premises in the United Kingdom, and 99% were of satisfactory microbiological quality. However, four samples (0.3%) were of an unsatisfactory quality (one with 800 CFU/g Listeria monocytogenes and three with >100 CFU/g Escherichia coli), and five samples (0.4%) were of a borderline quality owing to the presence of E. coli (two samples with a level of 20 CFU/g), Staphylococcus aureus (two samples with levels of >50 CFU/g), or L. monocytogenes (one sample with a level of 80 CFU/g). L. monocytogenes or other Listeria species were detected in a further 54 samples (4.5%) at levels below the threshold considered to be borderline or unsatisfactory. A significantly larger proportion of samples from one national supermarket chain was contaminated with L. monocytogenes than other supermarkets, and two types were, in this study, unique to this supermarket. This study shows that overall, the microbiological quality of ready-to-eat precut fruit was good. However, the presence of Listeria species in 5% of samples highlights the need for good hygiene during preparation and satisfactory temperature and time control during storage of these food products.

  5. Effect of biomimetic non-smooth unit morphology on thermal fatigue behavior of H13 hot-work tool steel

    Science.gov (United States)

    Meng, Chao; Zhou, Hong; Cong, Dalong; Wang, Chuanwei; Zhang, Peng; Zhang, Zhihui; Ren, Luquan

    2012-06-01

    The thermal fatigue behavior of hot-work tool steel processed by a biomimetic coupled laser remelting process gets a remarkable improvement compared to untreated sample. The 'dowel pin effect', the 'dam effect' and the 'fence effect' of non-smooth units are the main reason of the conspicuous improvement of the thermal fatigue behavior. In order to get a further enhancement of the 'dowel pin effect', the 'dam effect' and the 'fence effect', this study investigated the effect of different unit morphologies (including 'prolate', 'U' and 'V' morphology) and the same unit morphology in different sizes on the thermal fatigue behavior of H13 hot-work tool steel. The results showed that the 'U' morphology unit had the optimum thermal fatigue behavior, then the 'V' morphology which was better than the 'prolate' morphology unit; when the unit morphology was identical, the thermal fatigue behavior of the sample with large unit sizes was better than that of the small sizes.

  6. Jaguar taxonomy and genetic diversity for southern Arizona, United States, and Sonora, Mexico

    Science.gov (United States)

    Culver, Melanie; Hein, Alexander Ochoa

    2016-06-28

    Executive SummaryThe jaguar is the largest Neotropical felid and the only extant representative of the genus Panthera in the Americas. In recorded history, the jaguars range has extended from the Southern United States, throughout Mexico, to Central and South America, and they occupy a wide variety of habitats. A previous jaguar genetic study found high historical levels of gene flow among jaguar populations over broad areas but did not include any samples of jaguar from the States of Arizona, United States, or Sonora, Mexico. Arizona and Sonora have been part of the historical distribution of jaguars; however, poaching and habitat fragmentation have limited their distribution until they were declared extinct in the United States and endangered in Sonora. Therefore, a need was apparent to have this northernmost (Arizona/Sonora) jaguar population included in an overall jaguar molecular taxonomy and genetic diversity analyses. In this study, we used molecular genetic markers to examine diversity and taxonomy for jaguars in the Northwestern Jaguar Recovery Unit (NJRU; Sonora, Sinaloa, and Jalisco, Mexico; and southern Arizona and New Mexico, United States) relative to jaguars in other parts of the jaguar range (Central and South America). The objectives of this study were to:Collect opportunistic jaguar samples (hide, blood, hair, saliva, and scat), from historical and current individuals, that originated in NJRU areas of Arizona, New Mexico, and Sonora;Use these samples to assess molecular taxonomy of NJRU jaguars compared to data from a previous study of jaguars rangewide; andDevelop suggestions for conservation of NJRU jaguars based on the results.

  7. Sampling for stereology in lungs

    Directory of Open Access Journals (Sweden)

    J. R. Nyengaard

    2006-12-01

    Full Text Available The present article reviews the relevant stereological estimators for obtaining reliable quantitative structural data from the lungs. Stereological sampling achieves reliable, quantitative information either about the whole lung or complete lobes, whilst minimising the workload. Studies have used systematic random sampling, which has fixed and constant sampling probabilities on all blocks, sections and fields of view. For an estimation of total lung or lobe volume, the Cavalieri principle can be used, but it is not useful in estimating individual cell volume due to various effects from over- or underprojection. If the number of certain structures is required, two methods can be used: the disector and the fractionator. The disector method is a three-dimensional stereological probe for sampling objects according to their number. However, it may be affected on tissue deformation and, therefore, the fractionator method is often the preferred sampling principle. In this method, a known and predetermined fraction of an object is sampled in one or more steps, with the final step estimating the number. Both methods can be performed in a physical and optical manner, therefore enabling cells and larger lung structure numbers (e.g. number of alveoli to be estimated. Some estimators also require randomisation of orientation, so that all directions have an equal chance of being chosen. Using such isotropic sections, surface area, length, and diameter can be estimated on a Cavalieri set of sections. Stereology can also illustrate the potential for transport between two compartments by analysing the barrier width. Estimating the individual volume of cells can be achieved by local stereology using a two-step procedure that first samples lung cells using the disector and then introduces individual volume estimation of the sampled cells. The coefficient of error of most unbiased stereological estimators is a combination of variance from blocks, sections, fields

  8. Biodiversity of indigenous staphylococci of naturally fermented dry sausages and manufacturing environments of small-scale processing units.

    Science.gov (United States)

    Leroy, Sabine; Giammarinaro, Philippe; Chacornac, Jean-Paul; Lebert, Isabelle; Talon, Régine

    2010-04-01

    The staphylococcal community of the environments of nine French small-scale processing units and their naturally fermented meat products was identified by analyzing 676 isolates. Fifteen species were accurately identified using validated molecular methods. The three prevalent species were Staphylococcus equorum (58.4%), Staphylococcus saprophyticus (15.7%) and Staphylococcus xylosus (9.3%). S. equorum was isolated in all the processing units in similar proportion in meat and environmental samples. S. saprophyticus was also isolated in all the processing units with a higher percentage in environmental samples. S. xylosus was present sporadically in the processing units and its prevalence was higher in meat samples. The genetic diversity of the strains within the three species isolated from one processing unit was studied by PFGE and revealed a high diversity for S. equorum and S. saprophyticus both in the environment and the meat isolates. The genetic diversity remained high through the manufacturing steps. A small percentage of the strains of the two species share the two ecological niches. These results highlight that some strains, probably introduced by the meat, will persist in the manufacturing environment, while other strains are more adapted to the meat products.

  9. Specific detection of Aspergillus fumigatus in sputum sample of ...

    African Journals Online (AJOL)

    We developed a two-step PCR assay that specifically amplifies a region of the 18S rRNA gene that is highly conserved in Aspergillus fumigatus. This assay allows direct and rapid detection of down to 10 fg of Aspergillus fumigatus DNA corresponding to 1 to 5 colony forming unit (CFU) per ml of sputum sample of pulmonary ...

  10. BioSAXS Sample Changer: a robotic sample changer for rapid and reliable high-throughput X-ray solution scattering experiments

    Energy Technology Data Exchange (ETDEWEB)

    Round, Adam, E-mail: around@embl.fr; Felisaz, Franck [European Molecular Biology Laboratory, Grenoble Outstation, 71 Avenue des Martyrs, CS 90181, 38042 Grenoble (France); Université Grenoble Alpes–EMBL–CNRS, 71 Avenue des Martyrs, CS 90181, 38042 Grenoble (France); Fodinger, Lukas; Gobbo, Alexandre [European Molecular Biology Laboratory, Grenoble Outstation, 71 Avenue des Martyrs, CS 90181, 38042 Grenoble (France); Huet, Julien [European Molecular Biology Laboratory, Grenoble Outstation, 71 Avenue des Martyrs, CS 90181, 38042 Grenoble (France); Université Grenoble Alpes–EMBL–CNRS, 71 Avenue des Martyrs, CS 90181, 38042 Grenoble (France); Villard, Cyril [European Molecular Biology Laboratory, Grenoble Outstation, 71 Avenue des Martyrs, CS 90181, 38042 Grenoble (France); Blanchet, Clement E., E-mail: around@embl.fr [EMBL c/o DESY, Notkestrasse 85, 22603 Hamburg (Germany); Pernot, Petra; McSweeney, Sean [ESRF, 6 Rue Jules Horowitz, 38000 Grenoble (France); Roessle, Manfred; Svergun, Dmitri I. [EMBL c/o DESY, Notkestrasse 85, 22603 Hamburg (Germany); Cipriani, Florent, E-mail: around@embl.fr [European Molecular Biology Laboratory, Grenoble Outstation, 71 Avenue des Martyrs, CS 90181, 38042 Grenoble (France); Université Grenoble Alpes–EMBL–CNRS, 71 Avenue des Martyrs, CS 90181, 38042 Grenoble (France)

    2015-01-01

    A robotic sample changer for solution X-ray scattering experiments optimized for speed and to use the minimum amount of material has been developed. This system is now in routine use at three high-brilliance European synchrotron sites, each capable of several hundred measurements per day. Small-angle X-ray scattering (SAXS) of macromolecules in solution is in increasing demand by an ever more diverse research community, both academic and industrial. To better serve user needs, and to allow automated and high-throughput operation, a sample changer (BioSAXS Sample Changer) that is able to perform unattended measurements of up to several hundred samples per day has been developed. The Sample Changer is able to handle and expose sample volumes of down to 5 µl with a measurement/cleaning cycle of under 1 min. The samples are stored in standard 96-well plates and the data are collected in a vacuum-mounted capillary with automated positioning of the solution in the X-ray beam. Fast and efficient capillary cleaning avoids cross-contamination and ensures reproducibility of the measurements. Independent temperature control for the well storage and for the measurement capillary allows the samples to be kept cool while still collecting data at physiological temperatures. The Sample Changer has been installed at three major third-generation synchrotrons: on the BM29 beamline at the European Synchrotron Radiation Facility (ESRF), the P12 beamline at the PETRA-III synchrotron (EMBL@PETRA-III) and the I22/B21 beamlines at Diamond Light Source, with the latter being the first commercial unit supplied by Bruker ASC.

  11. Zeroing and testing units developed for Gerdien atmospheric ion detectors

    International Nuclear Information System (INIS)

    Kolarz, P.; Marinkovic, B.P.; Filipovic, D.M.

    2005-01-01

    Low current measurements in atmospheric ion detection using a Gerdien condenser are subjected to numerous sources of error. Zeroing and testing units described in this article, connected as modules to this type of detector, enable some of these errors to be found and eliminated. The zeroing unit provides digital compensation of the zero drift with a digital sample and hold circuit of 12-bit resolution. It overcomes difficulties related to zero drift and techniques used in the zero conductivity determination when the accelerating potential or airflow rate are zero. The testing unit is a current reference of nominally 10 -12 A intended for testing and correcting the system on current leakage and other measuring deviations due to changes in atmospheric parameters. This unit is an independent battery-powered module, which provides a charge of 10 -12 C per cycle (frequency of order 1 Hz) to the collecting electrode. The control of Gerdien devices is substantially simplified using the zeroing and testing units realized here. Both units are used during 'zero conductivity' regime only

  12. Organizational effects on patient satisfaction in hospital medical-surgical units.

    Science.gov (United States)

    Bacon, Cynthia Thornton; Mark, Barbara

    2009-05-01

    The purpose of this study was to examine the relationships between hospital context, nursing unit structure, and patient characteristics and patients' satisfaction with nursing care in hospitals. Although patient satisfaction has been widely researched, our understanding of the relationship between hospital context and nursing unit structure and their impact on patient satisfaction is limited. The data source for this study was the Outcomes Research in Nursing Administration Project, a multisite organizational study conducted to investigate relationships among nurse staffing, organizational context and structure, and patient outcomes. The sample for this study was 2,720 patients and 3,718 RNs in 286 medical-surgical units in 146 hospitals. Greater availability of nursing unit support services and higher levels of work engagement were associated with higher levels of patient satisfaction. Older age, better health status, and better symptom management were also associated with higher levels of patient satisfaction. Organizational factors in hospitals and nursing units, particularly support services on the nursing unit and mechanisms that foster nurses' work engagement and effective symptom management, are important influences on patient satisfaction.

  13. Student Teaching in the United States. Executive Summary

    Science.gov (United States)

    National Council on Teacher Quality, 2011

    2011-01-01

    In an effort to understand what makes a student teaching experience strong, the National Council on Teacher Quality (NCTQ) has undertaken this comprehensive review. Over a period of two years, NCTQ researchers examined the student teaching programs of a stratified random sample of 134 higher education institutions across the United States, with at…

  14. Development of a sample environment for neutron diffraction at low temperature

    International Nuclear Information System (INIS)

    Lee, Jeong Soo; Lee, Chang Hee; Choi, Yong Nam

    2000-06-01

    This report contains the development of low temperature sample environment for the neutron diffraction and its utilization techniques. With this research, a low temperature experimental facility of T=10-300 K was developed. We measured magnetic peak of La 1 .4Sr 1 .6Mn 2 O 7 due to low temperature phase transition successfully by this unit installed at the sample table of HRPD. Therefore, the research capability for various materials under the low temperature was expanded

  15. Complications of cesarean deliveries among HIV-infected women in the United States

    Science.gov (United States)

    Kourtis, Athena P.; Ellington, Sascha; Pazol, Karen; Flowers, Lisa; Haddad, Lisa; Jamieson, Denise J.

    2015-01-01

    Objective To compare rates of complications associated with cesarean delivery in HIV-infected and HIV-uninfected women in the United States and to investigate trends in such complications across four study cycles spanning the implementation of HAART in the United States (1995–1996, 2000–2001, 2005–2006, 2010–2011). Design The Nationwide Inpatient Sample from the Healthcare Cost and Utilization Project is the largest all-payer hospital inpatient care database in the United States; when weighted to account for the complex sampling design, nationally representative estimates are derived. After restricting the study sample to women aged 15–49 years, our study sample consisted of approximately 1 090 000 cesarean delivery hospitalizations annually. Methods Complications associated with cesarean deliveries were categorized as infection, hemorrhage, or surgical trauma, based on groups of specific International Classification of Diseases 9th revision codes. Length of hospitalization, hospital charges, and in-hospital deaths were also examined. Results The rate of complications significantly decreased during the study periods for HIV-infected and HIV-uninfected women. However, rates of infectious complications and surgical trauma associated with cesarean deliveries remained higher among HIV-infected, compared with HIV-uninfected women in 2010–2011, as did prolonged hospital stay and in-hospital deaths. Length of hospitalization decreased over time for cesarean deliveries of HIV-infected women to a greater extent compared with HIV-uninfected women. Conclusion In the United States, rates of cesarean delivery complications decreased from 1995 to 2011. However, rates of infection, surgical trauma, hospital deaths, and prolonged hospitalization are still higher among HIV-infected women. Clinicians should remain alert to this persistently increased risk of cesarean delivery complications among HIV-infected women. PMID:25574961

  16. A census-weighted, spatially-stratified household sampling strategy for urban malaria epidemiology

    Directory of Open Access Journals (Sweden)

    Slutsker Laurence

    2008-02-01

    Full Text Available Abstract Background Urban malaria is likely to become increasingly important as a consequence of the growing proportion of Africans living in cities. A novel sampling strategy was developed for urban areas to generate a sample simultaneously representative of population and inhabited environments. Such a strategy should facilitate analysis of important epidemiological relationships in this ecological context. Methods Census maps and summary data for Kisumu, Kenya, were used to create a pseudo-sampling frame using the geographic coordinates of census-sampled structures. For every enumeration area (EA designated as urban by the census (n = 535, a sample of structures equal to one-tenth the number of households was selected. In EAs designated as rural (n = 32, a geographically random sample totalling one-tenth the number of households was selected from a grid of points at 100 m intervals. The selected samples were cross-referenced to a geographic information system, and coordinates transferred to handheld global positioning units. Interviewers found the closest eligible household to the sampling point and interviewed the caregiver of a child aged Results 4,336 interviews were completed in 473 of the 567 study area EAs from June 2002 through February 2003. EAs without completed interviews were randomly distributed, and non-response was approximately 2%. Mean distance from the assigned sampling point to the completed interview was 74.6 m, and was significantly less in urban than rural EAs, even when controlling for number of households. The selected sample had significantly more children and females of childbearing age than the general population, and fewer older individuals. Conclusion This method selected a sample that was simultaneously population-representative and inclusive of important environmental variation. The use of a pseudo-sampling frame and pre-programmed handheld GPS units is more efficient and may yield a more complete sample than

  17. Incidence of constipation in an intensive care unit.

    Science.gov (United States)

    Guerra, Tatiana Lopes de Souza; Mendonça, Simone Sotero; Marshall, Norma Guimarães

    2013-01-01

    To evaluate the incidence of constipation in critical patients on enteral nutrition in a hospital intensive care unit and to correlate this incidence with the variables found for critical patients. The present investigation was a retrospective analytical study conducted in the intensive care unit of Hospital Regional da Asa Norte (DF) via the analysis of medical records of patients admitted during the period from January to December 2011. Data on the incidence of constipation and enteral nutritional support, gastrointestinal changes, stool frequency, ventilatory support, and outcomes were collected and analyzed. The initial sample consisted of 127 patients admitted to the unit during the period from January to December 2011. Eighty-four patients were excluded, and the final sample consisted of 43 patients. The incidence of constipation, defined as no bowel movement during the first 4 days of hospitalization, was 72% (n=31). The patients were divided into a control group and a constipated group. The group of constipated patients reached the caloric target, on average, at 6.5 days, and the control group reached the caloric target in 5.6 days (p=0.51). Constipation was not associated with the length of hospital stay, suspension of nutritional support, or outcome of hospitalization. There was an association between evacuation during hospitalization and a longer duration of hospitalization for a subgroup of patients who did not evacuate during the entire period (p=0.009). The incidence of constipation in the unit studied was 72%. Only the absence of evacuation during hospitalization was associated with longer hospital stays. Constipation was not associated with the length of hospital stay, suspension of nutritional support, or outcome of hospitalization.

  18. Job stress and locus of control in teachers: comparisons between samples from the United States and Zimbabwe

    Science.gov (United States)

    Crothers, Laura M.; Kanyongo, Gibbs Y.; Kolbert, Jered B.; Lipinski, John; Kachmar, Steven P.; Koch, Gary D.

    2010-12-01

    This study examines the relationship between educators' locus of control and job stress using samples from the US and Zimbabwe. Multiple regression analyses are used to identify significant relationships in the US sample between teachers' external locus of control and the severity of the job stress that they experience, coupled with the perceived degree of organisational support received. However, this relationship between the locus of control and stress indices could not be identified for the Zimbabwean sample. Significant differences between the two samples were noted in terms of educators' perceptions of the frequency of poor organisational support, with the Zimbabwean teachers reporting greater dissatisfaction. To explain these differences, a qualitative approach was utilised to illuminate the contextual stressors that educators face in Zimbabwe. The implications for teacher preparation measures are discussed.

  19. Nations United: The United Nations, the United States, and the Global Campaign Against Terrorism. A Curriculum Unit & Video for Secondary Schools.

    Science.gov (United States)

    Houlihan, Christina; McLeod, Shannon

    This curriculum unit and 1-hour videotape are designed to help students understand the purpose and functions of the United Nations (UN) and explore the relationship between the United Nations and the United States. The UN's role in the global counterterrorism campaign serves as a case study for the unit. The students are asked to develop a basic…

  20. 31 CFR 515.321 - United States; continental United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 515.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including the Trust Territory of...

  1. 31 CFR 500.321 - United States; continental United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 500.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including U.S. trust territories...

  2. 31 CFR 535.321 - United States; continental United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 535.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof including the Trust Territory of...

  3. Data report: western United States

    International Nuclear Information System (INIS)

    Cook, J.R.; Fay, W.M.

    1982-04-01

    This abbreviated summary data report, presents results of ground water and stream surface sediment reconnaissance in the western United States. Surface sediment samples were collected at 67,741 sites, at a target sampling density of one site per 13 square kilometers. Ground water samples were collected at 13,979 sites, and surface water samples were collected at 2,958 sites. Neutron activaton analysis results are given for uranium and 16 other elements in sediments, and for uranium and 9 other elements in waters. Mass spectrometry results are given for helium in ground waters. Supplemental analyses of the sediments for extractable uranium and 22 other elements are given where they are available. Supplemental analyses of water samples for 33 additional elements are also reported where they are available. Analytical data and field measurements are presented in tables on microfiche. Data from ground water sites (on microfiche in pocket) include (1) water chemistry measurements (pH, conductivity, and alkalinity), (2) physical measurements where applicable (water temperature, well description, and scintillometer reading), and (3) elemental analyses (U, Al, Br Cl, Dy, F, Mg, Mn, Na, and V by neutron activation and Ag, Al, As, B, Ba, Be, Ca, Ce, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Nb, Ni, P, Sc, Se, Si, Sr, Th, Ti, V, Y, Zn, and Zr by spectrophotometry). Helium analyses are given for ground water

  4. Further observations on comparison of immunization coverage by lot quality assurance sampling and 30 cluster sampling.

    Science.gov (United States)

    Singh, J; Jain, D C; Sharma, R S; Verghese, T

    1996-06-01

    Lot Quality Assurance Sampling (LQAS) and standard EPI methodology (30 cluster sampling) were used to evaluate immunization coverage in a Primary Health Center (PHC) where coverage levels were reported to be more than 85%. Of 27 sub-centers (lots) evaluated by LQAS, only 2 were accepted for child coverage, whereas none was accepted for tetanus toxoid (TT) coverage in mothers. LQAS data were combined to obtain an estimate of coverage in the entire population; 41% (95% CI 36-46) infants were immunized appropriately for their ages, while 42% (95% CI 37-47) of their mothers had received a second/ booster dose of TT. TT coverage in 149 contemporary mothers sampled in EPI survey was also 42% (95% CI 31-52). Although results by the two sampling methods were consistent with each other, a big gap was evident between reported coverage (in children as well as mothers) and survey results. LQAS was found to be operationally feasible, but it cost 40% more and required 2.5 times more time than the EPI survey. LQAS therefore, is not a good substitute for current EPI methodology to evaluate immunization coverage in a large administrative area. However, LQAS has potential as method to monitor health programs on a routine basis in small population sub-units, especially in areas with high and heterogeneously distributed immunization coverage.

  5. Improving the reliability of GUB-20000 gamma unit for large laboratory animals irradiation

    International Nuclear Information System (INIS)

    Videnskij, V.G.

    1994-01-01

    GUB-20000 gamma unit for large laboratory animals irradiation is described and results of investigation into its reliability improvement are considered. Cables of superstrength high-modular (SSHM) polymer fibre and capron fiber were tested to establish their applicability in the above unit. Samples were exposed to gamma-radiation and fast electrons and were tested for tensile properties. Application of SSHM-fiber cables to modernize the GUB-20000 unit was found to be perspective due to superhigh radiation strength. 5 refs., 1 tab

  6. The Living, Dynamic and Complex Environment Care in Intensive Care Unit.

    Science.gov (United States)

    Backes, Marli Terezinha Stein; Erdmann, Alacoque Lorenzini; Büscher, Andreas

    2015-01-01

    to understand the meaning of the Adult Intensive Care Unit environment of care, experienced by professionals working in this unit, managers, patients, families and professional support services, as well as build a theoretical model about the Adult Intensive Care Unit environment of care. Grounded Theory, both for the collection and for data analysis. Based on theoretical sampling, we carried out 39 in-depth interviews semi-structured from three different Adult Intensive Care Units. built up the so-called substantive theory "Sustaining life in the complex environment of care in the Intensive Care Unit". It was bounded by eight categories: "caring and continuously monitoring the patient" and "using appropriate and differentiated technology" (causal conditions); "Providing a suitable environment" and "having relatives with concern" (context); "Mediating facilities and difficulties" (intervenienting conditions); "Organizing the environment and managing the dynamics of the unit" (strategy) and "finding it difficult to accept and deal with death" (consequences). confirmed the thesis that "the care environment in the Intensive Care Unit is a living environment, dynamic and complex that sustains the life of her hospitalized patients".

  7. ANALISIS KEPUASAN SATUAN KERJA PERANGKAT DAERAH (SKPD DAN REKANAN TERHADAP KINERJA UNIT LAYANAN PENGADAAN (ULP PEMERINTAH KABUPATEN BADUNG

    Directory of Open Access Journals (Sweden)

    Putu Budayasa

    2016-01-01

    Full Text Available Abstract:Based on Presidential Decree Number 54 Year 2010 concerning Government Procurement of Goods / Services. Procurement process carried out by a unit called the Procurement Service Unit (PSU. In Government of Badung Regency, PSU was formed in 2011wich often get a negative presumption of those associated with the Unit is the Regional Work Unit and Partner Company when carry out the procurement process. Under these conditions it is necessary to evaluate the services given. The research aimed to determine the level of satisfaction Regional Work Unit and Partner Company of the performance of the Procurement Unit of Badung Regency and to investigate the influence of the five dimensions of service quality and satisfaction levels  wich is Tangible, Reliability, Responsiveness, Assurance and Empathy.Sampling using simple random sampling with a sample of 30 of Regional Work Unit and 71 of the Partner Company. Measuring the level of satisfaction is done by comparing the scores of hope with a score of respondents' perceptions of reality services received. While to know the factors that influence satisfaction of Partner company and regional work unit done by searching multiple linear regression model. The analysis was conducted to determine the effect or the relationship between variables, either partially or simultaneously.The results of descriptive analysis expressed Regional Work Unit satisfaction level is 86.28%, which factors most influence satisfaction is Assurance. Partner Company satisfaction level is 86.4% which factors most influence satisfaction is Tangible. Results inferential analysis states that the fifth dimension is influenced simultaneously and partially on both Regional Work Unit and Partner Company satisfaction .

  8. Rest lifetime evaluation and ageing management in NPP 'Kozloduy' unit 1-4

    International Nuclear Information System (INIS)

    Erve, M.; Heck, R.; Schmidt, J.; Daum, G.; Bataklieva, L.; Stoev, M.

    1999-01-01

    In 1992 as a result of an IAEA SRM review the 'WANO 6-month program' has been issued to improve operation, maintenance nad safety culture for the four WWER 440/230 units at the NPP 'Kozloduy' Siemens has awarded 3 contracts related to RTL evaluation of the main equipment, integrity of reactor pressure vessel and to the leak-before-break behaviour of the main piping od unit 2. It is pursuit an overall strategy that allows to: implement on the basis of RTL evaluation a long term ageing management program (AMAP) for Kozloduy's units 1-4 to assure their operation until the end of their design life; identify those components and equipment for which from the safety point of view urgent and immediate actions have to be performed; increase step by step the safety and reliability according to the Western standards and to internationally accepted safety culture; keep open the possibility of life extension as far as this would be technically feasible and acceptable and economically reasonable. Under the technical leadership of Siemens studies have been performed related to the subject of integrity and RTL, such as: reirradiation of RPV samples from Unit 1 and 2; evaluation of PV embrittlement of Unit 1; transfer of the results of LBB assessment of Unit 2 to Units 1, 3 and 4; transfer of results of RTL evaluation of Unit 2 to Units 1, 3 and 4; PTS analysis of RPV of Unit 1, 2,3 and 4. The main remarkable results are: no life-limiting mechanisms detected, requiring immediate actions, except for RPVs; residual lifetime determined for RPVs on reliable basis of advanced modern PTS analysis and sample testing; necessary activities in monitoring of ageing and in-service inspection clearly identified successful proof of lBB for main primary piping after slight modification of supports; international experts agreement reached (e.g. Risk Audit, successful IAEA experts meetings and OSART missions)

  9. Groundwater-Quality Data in the South Coast Range-Coastal Study Unit, 2008: Results from the California GAMA Program

    Science.gov (United States)

    Mathany, Timothy M.; Burton, Carmen A.; Land, Michael; Belitz, Kenneth

    2010-01-01

    Groundwater quality in the approximately 766-square-mile South Coast Range-Coastal (SCRC) study unit was investigated from May to December 2008, as part of the Priority Basins Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basins Project was developed in response to legislative mandates (Supplemental Report of the 1999 Budget Act 1999-00 Fiscal Year; and, the Groundwater Quality Monitoring Act of 2001 [Sections 10780-10782.3 of the California Water Code, Assembly Bill 599]) to assess and monitor the quality of groundwater in California, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The SCRC study unit was the 25th study unit to be sampled as part of the GAMA Priority Basins Project. The SCRC study unit was designed to provide a spatially unbiased assessment of untreated groundwater quality in the primary aquifer systems and to facilitate statistically consistent comparisons of untreated groundwater quality throughout California. The primary aquifer systems (hereinafter referred to as primary aquifers) were defined as that part of the aquifer corresponding to the perforation interval of wells listed in the California Department of Public Health (CDPH) database for the SCRC study unit. The quality of groundwater in shallow or deep water-bearing zones may differ from the quality of groundwater in the primary aquifers; shallow groundwater may be more vulnerable to surficial contamination. In the SCRC study unit, groundwater samples were collected from 70 wells in two study areas (Basins and Uplands) in Santa Barbara and San Luis Obispo Counties. Fifty-five of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells), and 15 wells were selected to aid in evaluation of specific water-quality issues (understanding wells). In addition to

  10. Groundwater-quality data for the Sierra Nevada study unit, 2008: Results from the California GAMA program

    Science.gov (United States)

    Shelton, Jennifer L.; Fram, Miranda S.; Munday, Cathy M.; Belitz, Kenneth

    2010-01-01

    Groundwater quality in the approximately 25,500-square-mile Sierra Nevada study unit was investigated in June through October 2008, as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Sierra Nevada study was designed to provide statistically robust assessments of untreated groundwater quality within the primary aquifer systems in the study unit, and to facilitate statistically consistent comparisons of groundwater quality throughout California. The primary aquifer systems (hereinafter, primary aquifers) are defined by the depth of the screened or open intervals of the wells listed in the California Department of Public Health (CDPH) database of wells used for public and community drinking-water supplies. The quality of groundwater in shallower or deeper water-bearing zones may differ from that in the primary aquifers; shallow groundwater may be more vulnerable to contamination from the surface. In the Sierra Nevada study unit, groundwater samples were collected from 84 wells (and springs) in Lassen, Plumas, Butte, Sierra, Yuba, Nevada, Placer, El Dorado, Amador, Alpine, Calaveras, Tuolumne, Madera, Mariposa, Fresno, Inyo, Tulare, and Kern Counties. The wells were selected on two overlapping networks by using a spatially-distributed, randomized, grid-based approach. The primary grid-well network consisted of 30 wells, one well per grid cell in the study unit, and was designed to provide statistical representation of groundwater quality throughout the entire study unit. The lithologic grid-well network is a secondary grid that consisted of the wells in the primary grid-well network plus 53 additional wells and was designed to provide statistical representation of groundwater quality in each of the four major lithologic units in the Sierra

  11. Glove box adaptation, installation and commissioning of an assembled modular type atomic absorption unit with GF atomizer

    International Nuclear Information System (INIS)

    Gupta, Santosh Kumar; Thulasidas, S.K.; Goyal, Neelam; Godbole, S.V.

    2013-09-01

    The report describes glove box adaptation of an in-house developed AAS unit with GF as atomization source for determination of trace metallic elements in Pu bearing samples. In order to replace the old Varian Techtron GF-AAS which was utilized for analysis of Pu bearing samples for the last thirty seven years, and as of late was giving too many practical problems, a new GF-AAS was designed and reassembled. The original compact flame AAS unit available with M/s. Thermo Fisher India Pvt. Ltd, Nashik, was converted into separated modular unit viz. Hollow Cathode Lamp unit, Atomizer unit and Monochromator - Detector - Readout unit. In addition, these modular units were modified with respect to their dimensions so as to enable their use with existing glove box facility developed earlier in 1980 for glove box incorporation. These units were separated from each other at their factory site so as to enable us to incorporate atomizer unit alone in the glove box. Glove box adapted GF-AAS is essential for Radiochemistry Division to provide analytical services to Chemical Quality Control of Pu bearing nuclear and related materials and also as an analytical support to the R and D activities of the Radiochemistry Division, BARC. (author)

  12. The Nature, Origin, and Importance of Carbonate-Bearing Samples at the Final Three Candidate Mars 2020 Landing Sites

    Science.gov (United States)

    Horgan, B.; Anderson, R. B.; Ruff, S. W.

    2018-04-01

    All three candidate Mars 2020 landing sites contain similar regional olivine/carbonate units, and a carbonate unit of possible lacustrine origin is also present at Jezero. Carbonates are critical for Mars Sample Return as records of climate and biosignatures.

  13. Mitochondrial DNA diversity of honey bees (Apis mellifera) from unmanaged colonies and swarms in the United States.

    Science.gov (United States)

    Magnus, Roxane M; Tripodi, Amber D; Szalanski, Allen L

    2014-06-01

    To study the genetic diversity of honey bees (Apis mellifera L.) from unmanaged colonies in the United States, we sequenced a portion of the mitochondrial DNA COI-COII region. From the 530 to 1,230 bp amplicon, we observed 23 haplotypes from 247 samples collected from 12 states, representing three of the four A. mellifera lineages known to have been imported into the United States (C, M, and O). Six of the 13 C lineage haplotypes were not found in previous queen breeder studies in the United States. The O lineage accounted for 9% of unmanaged colonies which have not yet been reported in queen breeder studies. The M lineage accounted for a larger portion of unmanaged samples (7%) than queen breeder samples (3%). Based on our mitochondrial DNA data, the genetic diversity of unmanaged honey bees in the United States differs significantly from that of queen breeder populations (p < 0.00001). The detection of genetically distinct maternal lineages of unmanaged honey bees suggests that these haplotypes may have existed outside the managed honey bee population for a long period.

  14. Extending laboratory automation to the wards: effect of an innovative pneumatic tube system on diagnostic samples and transport time.

    Science.gov (United States)

    Suchsland, Juliane; Winter, Theresa; Greiser, Anne; Streichert, Thomas; Otto, Benjamin; Mayerle, Julia; Runge, Sören; Kallner, Anders; Nauck, Matthias; Petersmann, Astrid

    2017-02-01

    The innovative pneumatic tube system (iPTS) transports one sample at a time without the use of cartridges and allows rapid sending of samples directly into the bulk loader of a laboratory automation system (LAS). We investigated effects of the iPTS on samples and turn-around time (TAT). During transport, a mini data logger recorded the accelerations in three dimensions and reported them in arbitrary area under the curve (AUC) units. In addition representative quantities of clinical chemistry, hematology and coagulation were measured and compared in 20 blood sample pairs transported by iPTS and courier. Samples transported by iPTS were brought to the laboratory (300 m) within 30 s without adverse effects on the samples. The information retrieved from the data logger showed a median AUC of 7 and 310 arbitrary units for courier and iPTS transport, respectively. This is considerably below the reported limit for noticeable hemolysis of 500 arbitrary units. iPTS reduces TAT by reducing the hands-on time and a fast transport. No differences in the measurement results were found for any of the investigated 36 analytes between courier and iPTS transport. Based on these findings the iPTS was cleared for clinical use in our hospital.

  15. Malaria Surveillance - United States, 2014.

    Science.gov (United States)

    Mace, Kimberly E; Arguin, Paul M

    2017-05-26

    Malaria in humans is caused by intraerythrocytic protozoa of the genus Plasmodium. These parasites are transmitted by the bite of an infective female Anopheles mosquito. The majority of malaria infections in the United States occur among persons who have traveled to regions with ongoing malaria transmission. However, malaria is occasionally acquired by persons who have not traveled out of the country through exposure to infected blood products, congenital transmission, laboratory exposure, or local mosquitoborne transmission. Malaria surveillance in the United States is conducted to identify episodes of local transmission and to guide prevention recommendations for travelers. This report summarizes cases in persons with onset of illness in 2014 and trends during previous years. Malaria cases diagnosed by blood film, polymerase chain reaction, or rapid diagnostic tests are reported to local and state health departments by health care providers or laboratory staff. Case investigations are conducted by local and state health departments, and reports are transmitted to CDC through the National Malaria Surveillance System, National Notifiable Diseases Surveillance System, or direct CDC consultations. CDC conducts antimalarial drug resistance marker testing on blood samples submitted by health care providers or local or state health departments. Data from these reporting systems serve as the basis for this report. CDC received reports of 1,724 confirmed malaria cases, including one congenital case and two cryptic cases, with onset of symptoms in 2014 among persons in the United States. The number of confirmed cases in 2014 is consistent with the number of confirmed cases reported in 2013 (n = 1,741; this number has been updated from a previous publication to account for delayed reporting for persons with symptom onset occurring in late 2013). Plasmodium falciparum, P. vivax, P. ovale, and P. malariae were identified in 66.1%, 13.3%, 5.2%, and 2.7% of cases, respectively

  16. Human resource management and unit performance in knowledge-intensive work.

    Science.gov (United States)

    Kehoe, Rebecca R; Collins, Christopher J

    2017-08-01

    To clarify the potential value of a targeted system of human resource (HR) practices, we explore the unique effects of a relationship-oriented HR system and the more commonly studied high commitment HR system on unit performance in the context of knowledge-intensive work. We develop theoretical arguments suggesting that the high commitment HR system contributes to unit performance through its positive effects on employees' collective organizational commitment, general and firm-specific human capital, and access to knowledge. We argue that the relationship-oriented HR system contributes to unit performance through its positive effects on employees' collective access to knowledge by fostering a social context and interpersonal exchange conditions which support employees' ongoing access to knowledge flows within and outside their unit and broader organization. Based on unit-level data collected from a matched sample of employees and managers in 128 units in the science and engineering division of a large hydroelectric power organization, our results suggest that the targeted, relationship-oriented HR system is related to firm performance and may complement a broader, high commitment approach to managing knowledge workers. Specifically, the positive relationship between the high commitment HR system and unit performance is mediated by employees' collective organizational commitment, firm-specific human capital, and access to knowledge in other organizational units; whereas the positive relationship between the relationship-oriented HR system and unit performance is mediated by units' access to knowledge within the unit, in other units, and outside the organization. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  17. Single blood-Hg samples can result in exposure misclassification: temporal monitoring within the Japanese community (United States

    Directory of Open Access Journals (Sweden)

    Tsuchiya Ami

    2012-06-01

    Full Text Available Abstract Background The most prominent non-occupational source of exposure to methylmercury is the consumption of fish. In this study we examine a fish consuming population to determine the extent of temporal exposure and investigate the extent to which single time estimates of methylmercury exposure based on blood-Hg concentration can provide reliable estimates of longer-term average exposure. Methods Blood-mercury levels were obtained from a portion of the Arsenic Mercury Intake Biometric Study (AMIBS cohort. Specifically, 56 Japanese women residing in the Puget Sound area of Washington State, US were sampled on three occasions across a one-year period. Results An average of 135 days separated samples, with mean blood-mercury levels for the visits being 5.1, 6.6 and 5.0 μg/l and geometric means being 2.7, 4.5 and 3.1 μg/l. The blood-mercury levels in this group exceed national averages with geometric means for two of the visits being between the 90th and 95th percentiles of nationally observed levels and the lowest geometric mean being between the 75th and 90th percentile. Group means were not significantly different across sampling periods suggesting that exposure of combined subjects remained relatively constant. Comparing intra-individual results over time did not reveal a strong correlation among visits (r = 0.19, 0.50, 0.63 between 1st and 2nd, 2nd and 3rd, and 1st and 3rd sample results, respectively. In comparing blood-mercury levels across two sampling interval combinations (1st and 2nd, 2nd and 3rd, and 1st and 3rd visits, respectively, 58% (n = 34, 53% (n = 31 and 29% (n = 17 of the individuals had at least a 100% difference in blood-Hg levels. Conclusions Point estimates of blood-mercury, when compared with three sample averages, may not reflect temporal variability and individual exposures estimated on the basis of single blood samples should be treated with caution as indicators of long-term exposure

  18. Towards diagnostic metagenomics of Campylobacter in fecal samples

    DEFF Research Database (Denmark)

    Andersen, Sandra Christine; Kiil, Kristoffer; Harder, Christoffer Bugge

    2017-01-01

    The development of diagnostic metagenomics is driven by the need for universal, culture-independent methods for detection and characterization of pathogens to substitute the time-consuming, organism-specific, and often culture-based laboratory procedures for epidemiological source-tracing. Some...... of the challenges in diagnostic metagenomics are, that it requires a great next-generation sequencing depth and unautomated data analysis. DNA from human fecal samples spiked with 7.75 × 101-7.75 × 107 colony forming unit (CFU)/ml Campylobacter jejuni and chicken fecal samples spiked with 1 × 102-1 × 106 CFU...... Campylobacter in all the clinical samples. Sensitivity in diagnostic metagenomics is improving and has reached a clinically relevant level. There are still challenges to overcome before real-time diagnostic metagenomics can replace quantitative polymerase chain reaction (qPCR) or culture-based surveillance...

  19. Nursing workload in a trauma intensive care unit

    Directory of Open Access Journals (Sweden)

    Luana Loppi Goulart

    2014-06-01

    Full Text Available Severely injured patients with multiple and conflicting injuries present themselves to nursing professionals at critical care units faced with care management challenges. The goal of the present study is to evaluate nursing workload and verify the correlation between workload and the APACHE II severity index. It is a descriptive study, conducted in the Trauma Intensive Care Unit of a teaching hospital. We used the Nursing Activities Score and APACHE II as instruments. The sample comprised 32 patients, of which most were male, young adults, presenting polytrauma, coming from the Reference Emergency Unit, in surgical treatment, and discharged from the ICU. The average obtained on the Nursing Activities Score instrument was 72% during hospitalization periods. The data displayed moderate correlation between workload and patient severity. In other words, the higher the score, the higher the patient’s mortality risk. doi: 10.5216/ree.v16i2.22922.

  20. Lifetime management of the nuclear units in France

    International Nuclear Information System (INIS)

    Combes, J-P.; Godin, R.

    1994-01-01

    A systematic design study entitled 'Lifetime Project' has been initiated at Electricite de France, to estimate, plan, and maximize the life span of the French PWR plants. It is estimated that the present units will have a lifetime of 30 to 50 years. The life of a unit will be determined by that of its components, by economic considerations (whether it is cheaper to repair or replace the unit), and by safety considerations, which may be affected by changing safety standards. A 'periodic safety reassessment' takes place about every ten years. A list of 18 critical components can be summarized by saying that the main concerns are: radiation embrittlement of and within the reactor vessel, the steam generators, the concrete containment (which can not be replaced), instrumentation and control. Examination of samples from decommissioned plants, such as Chooz A, will provide valuable evidence of mechanisms of degradation due to aging

  1. Test plan for core sampling drill bit temperature monitor

    International Nuclear Information System (INIS)

    Francis, P.M.

    1994-01-01

    At WHC, one of the functions of the Tank Waste Remediation System division is sampling waste tanks to characterize their contents. The push-mode core sampling truck is currently used to take samples of liquid and sludge. Sampling of tanks containing hard salt cake is to be performed with the rotary-mode core sampling system, consisting of the core sample truck, mobile exhauster unit, and ancillary subsystems. When drilling through the salt cake material, friction and heat can be generated in the drill bit. Based upon tank safety reviews, it has been determined that the drill bit temperature must not exceed 180 C, due to the potential reactivity of tank contents at this temperature. Consequently, a drill bit temperature limit of 150 C was established for operation of the core sample truck to have an adequate margin of safety. Unpredictable factors, such as localized heating, cause this buffer to be so great. The most desirable safeguard against exceeding this threshold is bit temperature monitoring . This document describes the recommended plan for testing the prototype of a drill bit temperature monitor developed for core sampling by Sandia National Labs. The device will be tested at their facilities. This test plan documents the tests that Westinghouse Hanford Company considers necessary for effective testing of the system

  2. The use of mini-samples in palaeomagnetism

    Science.gov (United States)

    Böhnel, Harald; Michalk, Daniel; Nowaczyk, Norbert; Naranjo, Gildardo Gonzalez

    2009-10-01

    Rock cores of ~25 mm diameter are widely used in palaeomagnetism. Occasionally smaller diameters have been used as well which represents distinct advantages in terms of throughput, weight of equipment and core collections. How their orientation precision compares to 25 mm cores, however, has not been evaluated in detail before. Here we compare the site mean directions and their statistical parameters for 12 lava flows sampled with 25 mm cores (standard samples, typically 8 cores per site) and with 12 mm drill cores (mini-samples, typically 14 cores per site). The site-mean directions for both sample sizes appear to be indistinguishable in most cases. For the mini-samples, site dispersion parameters k on average are slightly lower than for the standard samples reflecting their larger orienting and measurement errors. Applying the Wilcoxon signed-rank test the probability that k or α95 have the same distribution for both sizes is acceptable only at the 17.4 or 66.3 per cent level, respectively. The larger mini-core numbers per site appears to outweigh the lower k values yielding also slightly smaller confidence limits α95. Further, both k and α95 are less variable for mini-samples than for standard size samples. This is interpreted also to result from the larger number of mini-samples per site, which better averages out the detrimental effect of undetected abnormal remanence directions. Sampling of volcanic rocks with mini-samples therefore does not present a disadvantage in terms of the overall obtainable uncertainty of site mean directions. Apart from this, mini-samples do present clear advantages during the field work, as about twice the number of drill cores can be recovered compared to 25 mm cores, and the sampled rock unit is then more widely covered, which reduces the contribution of natural random errors produced, for example, by fractures, cooling joints, and palaeofield inhomogeneities. Mini-samples may be processed faster in the laboratory, which is of

  3. Reemergence of Mycobacterium chimaera in Heater-Cooler Units despite Intensified Cleaning and Disinfection Protocol.

    Science.gov (United States)

    Schreiber, Peter W; Kuster, Stefan P; Hasse, Barbara; Bayard, Cornelia; Rüegg, Christian; Kohler, Philipp; Keller, Peter M; Bloemberg, Guido V; Maisano, Francesco; Bettex, Dominique; Halbe, Maximilian; Sommerstein, Rami; Sax, Hugo

    2016-10-01

    Invasive Mycobacterium chimaera infections after open-heart surgery have been reported internationally. These devastating infections result from aerosols generated by contaminated heater-cooler units used with extracorporeal circulation during surgery. Despite intensified cleaning and disinfection, surveillance samples from factory-new units acquired during 2014 grew nontuberculous mycobacteria after a median of 174 days.

  4. Composition calculations by the KARATE code system for the spent-fuel samples from the Novovoronezh reactor

    International Nuclear Information System (INIS)

    Hordosy, G.

    2006-01-01

    KARATE is a code system developed in KFKI AERI. It is routinely used for core calculation. Its depletion module are now tested against the radiochemical measurements of spent fuel samples from the Novovoronezh Unit IV, performed in RIAR, Dimitrovgrad. Due to the insufficient knowledge of operational history of the unit, the irradiation history of the samples was taken from formerly published Russian calculations. The calculation of isotopic composition was performed by the MULTICEL module of program system. The agreement between the calculated and measured values of the concentration of the most important actinides and fission products is investigated (Authors)

  5. Influence of light-curing units and restorative materials on the micro hardness of resin cements

    Directory of Open Access Journals (Sweden)

    Kuguimiya Rosiane

    2010-01-01

    Full Text Available Aim: The aim of this study was to evaluate the effect of indirect restorative materials (IRMs and light-curing units (LCUs on the micro hardness of dual-cured resin cement. Materials and Methods: A total of 36 cylindrical samples (2 mm thick were prepared with dual-cured resin cement (Relyx ARC photo-activated with either a QTH (Optilight Plus for 40s or a LED (Radii light-curing unit for 65s. Photo-activation was performed through the 2-mm- thick IRMs and the samples were divided into six groups (n=6 according to the combination of veneering materials (without, ceramic and indirect resin and LCUs (QTH and LED. In the control group, the samples were light-cured with a QTH unit without the interposition of any restorative material. Vickers micro hardness test was performed on the top and bottom surfaces of each sample (load of 50 g for 15 secs. The data were statistically analyzed using a three-way ANOVA followed by Tukey x s post-hoc test ( P < 0.05. Results: There were no statistically significant differences on the top surface between the light curing-units ( P > 0.05; however, the LED provided greater hardness on the bottom surface when a ceramic material was used ( P < 0.05. The mean hardness in photo-activated samples, in which there was no interposition of indirect materials, was significantly greater ( P < 0.01. Conclusions: It may be concluded that the interposition of the restorative material decreased the micro hardness in the deeper cement layer. Such decrease, however, was lower when the ceramic was interposed and the cement light-cured with LED.

  6. Total Factor Productivity Convergence in Africa: Panel Unit Root ...

    African Journals Online (AJOL)

    The study tested absolute and conditional convergence of Total Factor Productivity in Africa using a sample of 23 countries and TFP data covering the period between 1960 and 2003 while deploying the panel unit root methodology. Countries that have experienced sustained economic growth rate are found to have ...

  7. Determinants Of Rural Agricultural Financing By The United Bank ...

    African Journals Online (AJOL)

    This study examined the determinants of rural agricultural financing by the United Bank for Africa (UBA) and the need for extension services in Imo State, Nigeria. Eighty (80) rural farmer loan beneficiaries from the UBA were sampled and administered with structured questionnaire. Results showed that the major significant ...

  8. Waste Area Group 10, Operable Unit 10-08, Remedial Investigation/Feasibility Study Annual Status Report for Fiscal Year 2006

    Energy Technology Data Exchange (ETDEWEB)

    R. P. Wells

    2007-05-09

    This report provides a status of the progress made in Fiscal Year 2006 on tasks identified in the Waste Area Group 10, Operable Unit 10-08, Remedial Investigation/Feasibility Study Work Plan. Major accomplishments include: (1) groundwater sampling and review of the groundwater monitoring data, (2) installation of a Sitewide groundwater-level monitoring network, (3) update of the Groundwater Monitoring and Field Sampling Plan of Operable Unit 10-08, (4) re-evaluation of the risk at Site TSF-08, (5) progress on the Operable Unit 10-08 Sitewide Groundwater Model.

  9. Novelly formed products of the interaction of fuel with construction materials of the 4th unit of Chernobyl NPP

    International Nuclear Information System (INIS)

    Borovoj, A.A.; Galkin, B.Ya.; Krinitsyn, A.P.; Pazukhin, Eh.M.; Kheruvimov, A.N.; Chechcherov, K.P.; Anderson, E.B.

    1991-01-01

    Radiation environment and map of sampling route in the steam distributing collector of the 4th unit of the Chernobyl NPP are described. The results of gamma- and alpha radiometric analyses as well as chemical analysis are presented. Samples of core materials taken from the depth of fuel-containing masses by drilling through reactor vault wall of the damaged power unit are described

  10. Depression and Suicidality among Bisexual Youth: A Nationally Representative Sample

    Science.gov (United States)

    Taliaferro, Lindsay A.; Gloppen, Kari M.; Muehlenkamp, Jennifer J.; Eisenberg, Marla E.

    2018-01-01

    To address gaps in the literature on bisexual youth, we used the first nationally representative sample of high school students from the United States to determine profiles of behaviors related to depressive symptoms, a suicide attempt, and a medically-serious attempt. We examined the data from 922 bisexual students in grades 9-12 who completed…

  11. Dispersion and sampling of adult Dermacentor andersoni in rangeland in Western North America.

    Science.gov (United States)

    Rochon, K; Scoles, G A; Lysyk, T J

    2012-03-01

    A fixed precision sampling plan was developed for off-host populations of adult Rocky Mountain wood tick, Dermacentor andersoni (Stiles) based on data collected by dragging at 13 locations in Alberta, Canada; Washington; and Oregon. In total, 222 site-date combinations were sampled. Each site-date combination was considered a sample, and each sample ranged in size from 86 to 250 10 m2 quadrats. Analysis of simulated quadrats ranging in size from 10 to 50 m2 indicated that the most precise sample unit was the 10 m2 quadrat. Samples taken when abundance mean-variance relationships were fit and used to predict sample sizes for a fixed level of precision. Sample sizes predicted using the Taylor model tended to underestimate actual sample sizes, while sample sizes estimated using the Iwao model tended to overestimate actual sample sizes. Using a negative binomial with common k provided estimates of required sample sizes closest to empirically calculated sample sizes.

  12. Bioenergetics of photoheterotrophic bacteria in the oceans.

    Science.gov (United States)

    Kirchman, David L; Hanson, Thomas E

    2013-04-01

    Photoheterotrophic microbes, such as proteorhodopsin (PR)-based phototrophic (PRP) and aerobic anoxygenic phototrophic (AAP) bacteria, are well known to be abundant in the oceans, potentially playing unique roles in biogeochemical cycles. However, the contribution of phototrophy to the energy requirements of these bacteria has not been quantitatively examined to date. To better understand the implications of photoheterophy in the oceans, we calculated energy benefits and costs of phototrophy and compared net benefits with maintenance costs. Benefits depend on the number of photosynthetic units (PSUs), absorption cross-section area of each PSU as function of wavelength, the in situ light quality, and the energy yield per absorbed photon. For costs we considered the energy required for the synthesis of pigments, amino acids and proteins in each PSU. Our calculations indicate that AAP bacteria harvest more light energy than do PRP bacteria, but the costs of phototrophy are much higher for AAP bacteria. Still, the net energy gained by AAP bacteria is often sufficient to meet maintenance costs, while that is not the case for PRP bacteria except with high light intensities and large numbers of proteorhodopsin molecules per cell. The low costs and simplicity of PR-based phototrophy explain the high abundance of proteorhodopsin genes in the oceans. However, even for AAP bacteria, the net energy yield of phototrophy is apparently too low to influence the distribution of photoheterotrophic bacteria among various marine systems. © 2012 Society for Applied Microbiology and Blackwell Publishing Ltd.

  13. Latent spatial models and sampling design for landscape genetics

    Science.gov (United States)

    Hanks, Ephraim M.; Hooten, Mevin B.; Knick, Steven T.; Oyler-McCance, Sara J.; Fike, Jennifer A.; Cross, Todd B.; Schwartz, Michael K.

    2016-01-01

    We propose a spatially-explicit approach for modeling genetic variation across space and illustrate how this approach can be used to optimize spatial prediction and sampling design for landscape genetic data. We propose a multinomial data model for categorical microsatellite allele data commonly used in landscape genetic studies, and introduce a latent spatial random effect to allow for spatial correlation between genetic observations. We illustrate how modern dimension reduction approaches to spatial statistics can allow for efficient computation in landscape genetic statistical models covering large spatial domains. We apply our approach to propose a retrospective spatial sampling design for greater sage-grouse (Centrocercus urophasianus) population genetics in the western United States.

  14. Robotic sample preparation for radiochemical plutonium and americium analyses

    International Nuclear Information System (INIS)

    Stalnaker, N.; Beugelsdijk, T.; Thurston, A.; Quintana, J.

    1985-01-01

    A Zymate robotic system has been assembled and programmed to prepare samples for plutonium and americium analyses by radioactivity counting. The system performs two procedures: a simple dilution procedure and a TTA (xylene) extraction of plutonium. To perform the procedures, the robotic system executes 11 unit operations such as weighing, pipetting, mixing, etc. Approximately 150 programs, which require 64 kilobytes of memory, control the system. The system is now being tested with high-purity plutonium metal and plutonium oxide samples. Our studies indicate that the system can give results that agree within 5% at the 95% confidence level with determinations performed manually. 1 ref., 1 fig., 1 tab

  15. Targeted surveillance for highly pathogenic avian influenza in migratory waterfowl across the conterminous United States: chapter 12

    Science.gov (United States)

    Farnsworth, Matthew L.; Kendall, William L.; Doherty, Paul F.; Miller, Ryan S.; White, Gary C.; Nichols, James D.; Burnham, Kenneth P.; Franklin, Alan B.; Majumdar, S.; Brenner, F.J.; Huffman, J.E.; McLean, R.G.; Panah, A.I.; Pietrobon, P.J.; Keeler, S.P.; Shive, S.

    2011-01-01

    Introduction of Asian strain H5N1 Highly Pathogenic avian influenca via waterfowl migration is one potential route of entry into the United States. In conjunction with state, tribe, and laboratory partners, the United States Department of Agriculture collected and tested 124,603 wild bird samples in 2006 as part of a national surveillance effort. A sampling plan was devised to increase the probability fo detecting Asian strain H5N1 at a national scale. Band recovery data were used to identify and prioritize sampling for wild migratory waterfowl, resulting in spatially targeted sampling recommendations focused on reads with high numbers of recoveries. We also compared the spatial and temporal distribution of the 2006 cloacal and fecal waterfowl sampling effort to the bird banding recovery data and found concordance between the two .Finally, we present improvements made to the 2007 fecal sampling component of the surveillance plan and suggest further improvements for future sampling.

  16. Reemergence of Mycobacterium chimaera in Heater–Cooler Units despite Intensified Cleaning and Disinfection Protocol

    Science.gov (United States)

    Schreiber, Peter W.; Kuster, Stefan P.; Hasse, Barbara; Bayard, Cornelia; Rüegg, Christian; Kohler, Philipp; Keller, Peter M.; Bloemberg, Guido V.; Maisano, Francesco; Bettex, Dominique; Halbe, Maximilian; Sommerstein, Rami

    2016-01-01

    Invasive Mycobacterium chimaera infections after open-heart surgery have been reported internationally. These devastating infections result from aerosols generated by contaminated heater–cooler units used with extracorporeal circulation during surgery. Despite intensified cleaning and disinfection, surveillance samples from factory-new units acquired during 2014 grew nontuberculous mycobacteria after a median of 174 days. PMID:27649345

  17. Automatic control unit for A neutron diffraction crystal spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Adib, M.; Abbas, Y.; Mostafa, M.; Hamouda, I.

    1982-01-01

    An automatic transistorized unit has been designed and constructed to control the operation of the double axis crystal spectrometer installed in front of one of the horizontal channels of the ET-RR-1 reactor. The function of the automatic unit is to store the diffracted neutrons at a certain angle with respect to the direction of the incident neutron beam in a selected channel of a 1024-multichannel analyzer for a certain preadjusted time period. AT the end of this time period the unit rotates the spectrometer's arm to another angle, selects the next channel of the MCA and provides the measurement of the diffracted neutron for the same time period. Such a sequence is repeated automatically over all angles required for the neutron diffraction pattern of the sample under investigation. As a result, the stored information at the MCA provides the neutron diffraction pattern as a function of channel number, where each channel corresponds to a certain scattering angle. The stored distribution at MCA can be obtained through the analyzer read out unit. The designed automatic unit has the possibility of providing the neutron diffraction pattern using a 6-digit scaler and a printer.

  18. Guidelines for the processing and quality assurance of benthic invertebrate samples collected as part of the National Water-Quality Assessment Program

    Science.gov (United States)

    Cuffney, T.F.; Gurtz, M.E.; Meador, M.R.

    1993-01-01

    Benthic invertebrate samples are collected as part of the U.S. Geological Survey's National Water-Quality Assessment Program. This is a perennial, multidisciplinary program that integrates biological, physical, and chemical indicators of water quality to evaluate status and trends and to develop an understanding of the factors controlling observed water quality. The Program examines water quality in 60 study units (coupled ground- and surface-water systems) that encompass most of the conterminous United States and parts of Alaska and Hawaii. Study-unit teams collect and process qualitative and semi-quantitative invertebrate samples according to standardized procedures. These samples are processed (elutriated and subsampled) in the field to produce as many as four sample components: large-rare, main-body, elutriate, and split. Each sample component is preserved in 10-percent formalin, and two components, large-rare and main-body, are sent to contract laboratories for further processing. The large-rare component is composed of large invertebrates that are removed from the sample matrix during field processing and placed in one or more containers. The main-body sample component consists of the remaining sample materials (sediment, detritus, and invertebrates) and is subsampled in the field to achieve a volume of 750 milliliters or less. The remaining two sample components, elutriate and split, are used for quality-assurance and quality-control purposes. Contract laboratories are used to identify and quantify invertebrates from the large-rare and main-body sample components according to the procedures and guidelines specified within this document. These guidelines allow the use of subsampling techniques to reduce the volume of sample material processed and to facilitate identifications. These processing procedures and techniques may be modified if the modifications provide equal or greater levels of accuracy and precision. The intent of sample processing is to

  19. Sample size estimation and sampling techniques for selecting a representative sample

    Directory of Open Access Journals (Sweden)

    Aamir Omair

    2014-01-01

    Full Text Available Introduction: The purpose of this article is to provide a general understanding of the concepts of sampling as applied to health-related research. Sample Size Estimation: It is important to select a representative sample in quantitative research in order to be able to generalize the results to the target population. The sample should be of the required sample size and must be selected using an appropriate probability sampling technique. There are many hidden biases which can adversely affect the outcome of the study. Important factors to consider for estimating the sample size include the size of the study population, confidence level, expected proportion of the outcome variable (for categorical variables/standard deviation of the outcome variable (for numerical variables, and the required precision (margin of accuracy from the study. The more the precision required, the greater is the required sample size. Sampling Techniques: The probability sampling techniques applied for health related research include simple random sampling, systematic random sampling, stratified random sampling, cluster sampling, and multistage sampling. These are more recommended than the nonprobability sampling techniques, because the results of the study can be generalized to the target population.

  20. A Literature Unit for "Dragon's Gate" by Laurence Yep.

    Science.gov (United States)

    Thomas-Vallens, Mary

    Intended as a an aid to classroom teachers, this 52-page handbook presents a literature unit based on the children and young people's book, "Dragon's Gate" by Laurence Yep. It begins with sample lesson plans, pre-reading activities, author information, a book summary, vocabulary lists and suggested vocabulary activities. Next, chapters…

  1. Condom use during most recent vaginal intercourse event among a probability sample of adults in the United States.

    Science.gov (United States)

    Sanders, Stephanie A; Reece, Michael; Herbenick, Debby; Schick, Vanessa; Dodge, Brian; Fortenberry, J Dennis

    2010-10-01

    Correct and consistent condom use remains the most effective way to reduce sexually transmissible infection/HIV transmission during sex and is a highly effective contraceptive method. Understanding correlates of condom use is vital to public health programs. To explore sociodemographic, event characteristics, and experiential correlates of condom use at last penile-vaginal intercourse (PVI). Survey data were collected from a nationally representative probability sample of adults in the United States as part of the National Survey of Sexual Health and Behavior. Condom use/non-use at most recent PVI was the main outcome. Logistic regression analyses predicted condom use from sociodemographic variables (i.e., age, education, race/ethnicity, sexual orientation, health status, type of relationship with sexual partner) and event characteristics (i.e., location of sexual encounter, prior intercourse experience with partner, whether partner had other sex partners in the 6 months prior to sex with the participant; other contraceptive use, alcohol use, marijuana use, and for men, erection medication use). Logistic regression analyses examined evaluations of the sexual aspects of the experience (pleasure, arousal, erection/lubrication difficulty, participant orgasm, partner orgasm) in light of condom use. Condom-protected PVI was significantly greater among younger people, blacks and Hispanics, and those having PVI with a nonrelationship partner. Statistically adjusting for these differences, condom use was significantly associated with fewer previous intercourse experiences with the partner and not using other forms of contraception. The sexual aspects of experience were evaluated similarly regardless of whether or not a condom was used. Public health programs among youths and minorities may underlie higher condom use rates among these groups. Condom use may be further improved by continuing such programs and also expanding outreach to older persons and whites, suggesting

  2. Sampling and analysis of 100 Area springs

    International Nuclear Information System (INIS)

    1992-02-01

    This report is submitted in fulfillment of Hanford Federal Facility Agreement and Consent Order Milestone M-30-01, submit a report to EPA and Ecology evaluating the impact to the Columbia River from contaminated springs and seeps as described in the operable unit work plans listed in M-30-03. Springs, seeps, sediments, and the Columbia River were sampled for chemical and radiological analyses during the period September 16 through October 21, 1991. A total of 26 locations were sampled. Results of these analyses show that radiological and nonradiological contaminants continue to enter the Columbia River from the retired reactor areas of the 100 Area via the springs. The primary contaminants in the springs are strontium-90, tritium, and chromium. These contaminants were detected in concentrations above drinking water standards. Analysis of total organic carbon were run on all water samples collected; there is no conclusive evidence that organic constituents are entering the river through the springs. Total organic carbon analyses were generally higher for the surface water than for the springs. The results of this study will be used to develop a focused, yet flexible, long-term spring sampling program. Analysis of Columbia River water samples collected at the Hanford Townsite (i.e., downstream of the reactor areas) did not detect any Hanford-specific contaminants

  3. Time recording unit for a neutron time of flight spectrometer

    International Nuclear Information System (INIS)

    Puranik, Praful; Ajit Kiran, S.; Chandak, R.M.; Poudel, S.K.; Mukhopadhyay, R.

    2011-01-01

    Here the architecture and design of Time Recording Unit for a Neutron Time of Flight Spectrometer have been described. The Spectrometer would have an array of 50 Nos. of one meter long linear Position Sensitive Detector (PSD) placed vertically around the sample at a distance of 2000 mm. The sample receives periodic pulsed neutron beam coming through a Fermi chopper. The time and zone of detection of a scattered neutron in a PSD gives information of its flight time and path length, which will be used to calculate its energy. A neutron event zone (position) and time detection module for each PSD provides a 2 bit position/zone code and an event timing pulse. The path length assigned to a neutron detected in a zone (Z1, Z2 etc) in the PSD is the mean path length seen by the neutrons detected in that zone of the PSD. A Time recording unit described here receives event zone code and timing pulse for all the 50 detectors, tags a proper time window code to it, before streaming it to computer for calculation of the energy distribution of neutrons scattered from the sample

  4. Job Stress and Locus of Control in Teachers: Comparisons between Samples from the United States and Zimbabwe

    Science.gov (United States)

    Crothers, Laura M.; Kanyongo, Gibbs Y.; Kolbert, Jered B.; Lipinski, John; Kachmar, Steven P.; Koch, Gary D.

    2010-01-01

    This study examines the relationship between educators' locus of control and job stress using samples from the US and Zimbabwe. Multiple regression analyses are used to identify significant relationships in the US sample between teachers' external locus of control and the severity of the job stress that they experience, coupled with the perceived…

  5. Does size matter? Animal units and animal unit months

    Science.gov (United States)

    Lamar Smith; Joe Hicks; Scott Lusk; Mike Hemmovich; Shane Green; Sarah McCord; Mike Pellant; John Mitchell; Judith Dyess; Jim Sprinkle; Amanda Gearhart; Sherm Karl; Mike Hannemann; Ken Spaeth; Jason Karl; Matt Reeves; Dave Pyke; Jordan Spaak; Andrew Brischke; Del Despain; Matt Phillippi; Dave Weixelmann; Alan Bass; Jessie Page; Lori Metz; David Toledo; Emily Kachergis

    2017-01-01

    The concepts of animal units, animal unit months, and animal unit equivalents have long been used as standards for range management planning, estimating stocking rates, reporting actual use, assessing grazing fees, ranch appraisal, and other purposes. Increasing size of cattle on rangelands has led some to suggest that the definition of animal units and animal unit...

  6. Evaluation of the Financial and Operating Performance of Fertilizers and Chemical & Pharmaceutical Sectors of Indian Public Sector Enterprises After Disinvestment

    Directory of Open Access Journals (Sweden)

    DR. GAGAN SINGH

    2014-04-01

    Full Text Available After 1991 the Government of India is following a policy of economic liberalisation and concept of disinvestment has been more or less accepted by at least all the parties whenever they are Government Disinvestment involves the sale of equity and bond capital invested by the government in PSUs. The failure of the public sector to fulfill the role assigned to it resulted in the protest become louder and more articulate. The main focus of the present paper is to examine the impact of disinvestment on the financial and operating performance of fertilizers and chemical & pharmaceutical sectors of Indian Public sector enterprises. April 2009 onwards, there are fourteen enterprises in which government has undertaken disinvestment recently. After partial disinvestment of both fertilizers and chemical & pharmaceutical sectors of Indian Public sector enterprises, their dependence on the outsiders’ funds has been increased+

  7. June 2012 Groundwater Sampling at the Central Nevada Test Area (Data Validation Package)

    International Nuclear Information System (INIS)

    2013-01-01

    The U.S. Department of Energy Office of Legacy Management conducted annual sampling at the Central Nevada Test Area (CNTA) on June 26-27, 2012, in accordance with the 2004 Correction Action Decision Document/Corrective Action Plan for Corrective Action Unit 443: Central Nevada Test Area (CNTA)-Subsurface and the addendum to the 'Corrective Action Decision Document/Corrective Action Plan' completed in 2008. Sampling and analysis were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PLN/S04351), continually updated).

  8. May 2011 Groundwater Sampling at the Central Nevada Test Area (Data Validation Package)

    International Nuclear Information System (INIS)

    2011-01-01

    The U.S. Department of Energy Office of Legacy Management conducted annual sampling at the Central Nevada Test Area (CNTA) on May 10-11, 2011, in accordance with the 2004 Correction Action Decision Document/Corrective Action Plan for Corrective Action Unit 443: Central Nevada Test Area (CNTA)-Subsurface and the addendum to the 'Corrective Action Decision Document/Corrective Action Plan' completed in 2008. Sampling and analysis were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PLN/S04351), continually updated)

  9. The Living, Dynamic and Complex Environment Care in Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Marli Terezinha Stein Backes

    2015-06-01

    Full Text Available OBJECTIVE: to understand the meaning of the Adult Intensive Care Unit environment of care, experienced by professionals working in this unit, managers, patients, families and professional support services, as well as build a theoretical model about the Adult Intensive Care Unit environment of care.METHOD: Grounded Theory, both for the collection and for data analysis. Based on theoretical sampling, we carried out 39 in-depth interviews semi-structured from three different Adult Intensive Care Units.RESULTS: built up the so-called substantive theory "Sustaining life in the complex environment of care in the Intensive Care Unit". It was bounded by eight categories: "caring and continuously monitoring the patient" and "using appropriate and differentiated technology" (causal conditions; "Providing a suitable environment" and "having relatives with concern" (context; "Mediating facilities and difficulties" (intervenienting conditions; "Organizing the environment and managing the dynamics of the unit" (strategy and "finding it difficult to accept and deal with death" (consequences.CONCLUSION: confirmed the thesis that "the care environment in the Intensive Care Unit is a living environment, dynamic and complex that sustains the life of her hospitalized patients".

  10. Rapanos v. United States & Carabell v. United States

    Science.gov (United States)

    Documents associated with guidance for implementing the definition of waters of the United States under the Clean Water Act following the Rapanos v. United States, and Carabell v. United States Supreme Court decision.

  11. Periodontal Disease and Oral Hygiene Among Children. United States.

    Science.gov (United States)

    National Center for Health Statistics (DHEW/PHS), Hyattsville, MD.

    Statistical data presented on periodontal disease and oral hygiene among noninstitutionalized children, aged 6-11, in the United States are based on a probability sample of approximately 7,400 children involved in a national health survey during 1963-65. The report contains estimates of the Periodontal Index (PI) and the Simplified Oral Hygiene…

  12. Microstructural controls on the macroscopic behavior of geo-architected rock samples

    Science.gov (United States)

    Mitchell, C. A.; Pyrak-Nolte, L. J.

    2017-12-01

    Reservoir caprocks, are known to span a range of mechanical behavior from elastic granitic units to visco-elastic shale units. Whether a rock will behave elastically, visco-elastically or plastically depends on both the compositional and textural or microsctructural components of the rock, and how these components are spatially distributed. In this study, geo-architected caprock fabrication was performed to develop synthetic rock to study the role of rock rheology on fracture deformations, fluid flow and geochemical alterations. Samples were geo-architected with Portland Type II cement, Ottawa sand, and different clays (kaolinite, illite, and Montmorillonite). The relative percentages of these mineral components are manipulated to generate different rock types. With set protocols, the mineralogical content, texture, and certain structural aspects of the rock were controlled. These protocols ensure that identical samples with the same morphological and mechanical characteristics are constructed, thus overcoming issues that may arise in the presence of heterogeneity and high anisotropy from natural rock samples. Several types of homogeneous geo-architected rock samples were created, and in some cases the methods were varied to manipulate the physical parameters of the rocks. Characterization of rocks that the samples exhibit good repeatability. Rocks with the same mineralogical content generally yielded similar compressional and shear wave velocities, UCS and densities. Geo-architected rocks with 10% clay in the matrix had lower moisture content and effective porosities than rocks with no clay. The process by which clay is added to the matrix can strongly affect the resulting compressive strength and physical properties of the geo-architected sample. Acknowledgment: This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Geosciences Research Program under Award Number (DE-FG02-09ER16022).

  13. The work-family interface in the United States and Singapore: conflict across cultures.

    Science.gov (United States)

    Galovan, Adam M; Fackrell, Tamara; Buswell, Lydia; Jones, Blake L; Hill, E Jeffrey; Carroll, Sarah June

    2010-10-01

    This article examines the work-family interface in a cross-cultural comparison between two nationally representative samples from the United States (n = 1,860) and Singapore (n = 1,035) with emphasis on work-family conflict. Family-to-work conflict was negatively related to marital satisfaction in both Singapore and the United States, although the effect was stronger in the United States. Similarly, family-to-work conflict was positively related to job satisfaction in the United States but was negatively related in Singapore. As expected, schedule flexibility was negatively related to depression in the United States, but in Singapore the relationship was positive. These findings suggest that theoretical relationships in the work-family interface developed in the more culturally individualistic West may need to be adapted when studying populations in the more collectivist East.

  14. Assessing RN-to-RN peer review on clinical units.

    Science.gov (United States)

    Pfeiffer, Judith A; Wickline, Mary A; Deetz, Jill; Berry, Elise S

    2012-04-01

    The primary purpose of this study was to measure informal registered nurse (RN)-to-RN peer review (defined as collegial communication about the quality of nursing care) at the work-unit level. Survey design with cluster sampling of 28 hospital or ambulatory care units (n = 541 respondents). Results were compared with existing patient safety and satisfaction data. A chi-squared test was used to compare responses against nurse characteristics. Nurses agreed that RN-to-RN peer review takes place on their units, but no correlation with patient safety and satisfaction data was found. Misunderstandings about the meaning of peer review were evident. Open-ended comments revealed barriers to peer review: fear of retribution, language barriers and lack of professionalism. Nurses need clarification of peer review. Issues with common language in a professional environment need to be addressed and nurses can learn collaboration from each other's cultures. Managers should support RN-to-RN peer review on clinical units. Methods used here may be useful to assess current departmental nurse peer review. © 2011 Blackwell Publishing Ltd.

  15. SAMPL5: 3D-RISM partition coefficient calculations with partial molar volume corrections and solute conformational sampling

    Science.gov (United States)

    Luchko, Tyler; Blinov, Nikolay; Limon, Garrett C.; Joyce, Kevin P.; Kovalenko, Andriy

    2016-11-01

    Implicit solvent methods for classical molecular modeling are frequently used to provide fast, physics-based hydration free energies of macromolecules. Less commonly considered is the transferability of these methods to other solvents. The Statistical Assessment of Modeling of Proteins and Ligands 5 (SAMPL5) distribution coefficient dataset and the accompanying explicit solvent partition coefficient reference calculations provide a direct test of solvent model transferability. Here we use the 3D reference interaction site model (3D-RISM) statistical-mechanical solvation theory, with a well tested water model and a new united atom cyclohexane model, to calculate partition coefficients for the SAMPL5 dataset. The cyclohexane model performed well in training and testing (R=0.98 for amino acid neutral side chain analogues) but only if a parameterized solvation free energy correction was used. In contrast, the same protocol, using single solute conformations, performed poorly on the SAMPL5 dataset, obtaining R=0.73 compared to the reference partition coefficients, likely due to the much larger solute sizes. Including solute conformational sampling through molecular dynamics coupled with 3D-RISM (MD/3D-RISM) improved agreement with the reference calculation to R=0.93. Since our initial calculations only considered partition coefficients and not distribution coefficients, solute sampling provided little benefit comparing against experiment, where ionized and tautomer states are more important. Applying a simple pK_{ {a}} correction improved agreement with experiment from R=0.54 to R=0.66, despite a small number of outliers. Better agreement is possible by accounting for tautomers and improving the ionization correction.

  16. SAMPL5: 3D-RISM partition coefficient calculations with partial molar volume corrections and solute conformational sampling.

    Science.gov (United States)

    Luchko, Tyler; Blinov, Nikolay; Limon, Garrett C; Joyce, Kevin P; Kovalenko, Andriy

    2016-11-01

    Implicit solvent methods for classical molecular modeling are frequently used to provide fast, physics-based hydration free energies of macromolecules. Less commonly considered is the transferability of these methods to other solvents. The Statistical Assessment of Modeling of Proteins and Ligands 5 (SAMPL5) distribution coefficient dataset and the accompanying explicit solvent partition coefficient reference calculations provide a direct test of solvent model transferability. Here we use the 3D reference interaction site model (3D-RISM) statistical-mechanical solvation theory, with a well tested water model and a new united atom cyclohexane model, to calculate partition coefficients for the SAMPL5 dataset. The cyclohexane model performed well in training and testing ([Formula: see text] for amino acid neutral side chain analogues) but only if a parameterized solvation free energy correction was used. In contrast, the same protocol, using single solute conformations, performed poorly on the SAMPL5 dataset, obtaining [Formula: see text] compared to the reference partition coefficients, likely due to the much larger solute sizes. Including solute conformational sampling through molecular dynamics coupled with 3D-RISM (MD/3D-RISM) improved agreement with the reference calculation to [Formula: see text]. Since our initial calculations only considered partition coefficients and not distribution coefficients, solute sampling provided little benefit comparing against experiment, where ionized and tautomer states are more important. Applying a simple [Formula: see text] correction improved agreement with experiment from [Formula: see text] to [Formula: see text], despite a small number of outliers. Better agreement is possible by accounting for tautomers and improving the ionization correction.

  17. 200-ZP-1 operable unit borehole summary report for FY 1995 and FY 1996

    International Nuclear Information System (INIS)

    Darrach, M.E.

    1996-10-01

    This document details the well construction, sampling, analyses, and geologic character of the Ringold Formation fluvial unit E gravels as encountered in 16 boreholes in the 200-ZP-1 Operable Unit. These boreholes were drilled by Water Development Hanford Corporation during fiscal years 1995 and 1996. Two of the sixteen boreholes were abandoned; the remaining 14 boreholes were completed as functioning production and compliance wells. The borehole logs and well summary sheets included as Appendices A and B of this document, respectively, depict and describe the vadose zone stratigraphic units encountered during the course of drilling. Appendix C contains the results of sieve analyses conducted on samples obtained via resonant sonic coring and standard split-spoon methods. The sieve analyses were the driver behind the majority of the well designs. Also, for completeness, Appendices D and E contain the well design calculations and the well development process

  18. Potential impacts of year-round sampling on monitoring presence- absence of invasive flora in the southern United States

    Science.gov (United States)

    Christopher M. Oswalt; Sonja N. Oswalt; W. Keith Moser

    2012-01-01

    Studies suggest that the southern United States is an area of primary concern with regards to the spread of nonnative invasive plant species. Recent data show that species such as Japanese honeysuckle (Lonicera japonica) and Nepalese browntop (Microstegium vimineum) are invading forests and displacing native species throughout the...

  19. Child maltreatment and eating disorders among men and women in adulthood: Results from a nationally representative United States sample.

    Science.gov (United States)

    Afifi, Tracie O; Sareen, Jitender; Fortier, Janique; Taillieu, Tamara; Turner, Sarah; Cheung, Kristene; Henriksen, Christine A

    2017-11-01

    Child maltreatment is associated with an increased likelihood of having mood disorders, anxiety disorders, post-traumatic stress disorder, substance use disorders, and personality disorders, but far less is known about eating disorders. The objective of the current study was to examine the associations between child maltreatment, including harsh physical punishment, physical abuse, sexual abuse, emotional abuse, emotional neglect, physical neglect, and exposure to intimate partner violence, and eating disorders in adulthood among men and women. Data were from the National Epidemiologic Survey on Alcohol and Related Conditions wave 3 (NESARC-III) collected in 2012-2013. The sample was nationally representative of the United States adult population (N = 36,309). Lifetime eating disorders (anorexia nervosa [AN], bulimia nervosa [BN], and binge-eating disorder [BED]) were assessed using diagnostic and statistical manual of mental disorders, fifth edition (DSM-5) criteria and the alcohol use disorder and associated disabilities interview schedule-5 (AUDADIS-5). The prevalence of any lifetime eating disorder was 1.7% (0.8% among men and 2.7% among women). All child maltreatment types were associated with AN, BN, and BED with notable differences among men and women. Overall, the types of child maltreatment with the strongest relationships with any eating disorder were sexual abuse and physical neglect among men and sexual abuse and emotional abuse among women. Clinicians should be mindful that child maltreatment experiences are associated with increased odds of eating disorders including AN, BED, and BN. Such relationships are significant among men and women although notable gender differences in these relationships exist. Abstract word count = 248. © 2017 The Authors International Journal of Eating Disorders Published by Wiley Periodicals, Inc.

  20. Inpatient Financial Burden of Atopic Dermatitis in the United States

    DEFF Research Database (Denmark)

    Narla, Shanthi; Hsu, Derek Y; Thyssen, Jacob P

    2017-01-01

    Little is known about the inpatient burden of atopic dermatitis (AD). We sought to determine the risk factors and financial burden of hospitalizations for AD in the United States. Data were analyzed from the 2002-2012 National Inpatient Sample, including a 20% representative sample of all...... hospitalizations in the United States. Hospitalization rates for AD or eczema were highest in the northeast during the winter and south during the summer. Geometric mean cost of care (95% confidence interval) was lower for a primary diagnosis of AD or eczema versus no AD or eczema in adults ($3,502 [$3......,360-$3,651] vs. $6,849 [$6,775-$6,925]; P = 0.0004) and children ($2,716 [$2,542-$2,903] vs. $4,488 [$4,302-$4,682]; P = 0.0004). However, the high prevalence of hospitalization resulted in total inpatient costs of $8,288,083 per year for adults and $3,333,868 per year for children. In conclusion...

  1. Modeling Forest Succession among Ecological Land Units in Northern Minnesota

    Directory of Open Access Journals (Sweden)

    George Host

    1998-12-01

    Full Text Available Field and modeling studies were used to quantify potential successional pathways among fine-scale ecological classification units within two geomorphic regions of north-central Minnesota. Soil and overstory data were collected on plots stratified across low-relief ground moraines and undulating sand dunes. Each geomorphic feature was sampled across gradients of topography or soil texture. Overstory conditions were sampled using five variable-radius point samples per plot; soil samples were analyzed for carbon and nitrogen content. Climatic, forest composition, and soil data were used to parameterize the sample plots for use with LINKAGES, a forest growth model that simulates changes in composition and soil characteristics over time. Forest composition and soil properties varied within and among geomorphic features. LINKAGES simulations were using "bare ground" and the current overstory as starting conditions. Northern hardwoods or pines dominated the late-successional communities of morainal and dune landforms, respectively. The morainal landforms were dominated by yellow birch and sugar maple; yellow birch reached its maximum abundance in intermediate landscape positions. On the dune sites, pine was most abundant in drier landscape positions, with white spruce increasing in abundance with increasing soil moisture and N content. The differences in measured soil properties and predicted late-successional composition indicate that ecological land units incorporate some of the key variables that govern forest composition and structure. They further show the value of ecological classification and modeling for developing forest management strategies that incorporate the spatial and temporal dynamics of forest ecosystems.

  2. Solid recovered fuels in the cement industry--semi-automated sample preparation unit as a means for facilitated practical application.

    Science.gov (United States)

    Aldrian, Alexia; Sarc, Renato; Pomberger, Roland; Lorber, Karl E; Sipple, Ernst-Michael

    2016-03-01

    One of the challenges for the cement industry is the quality assurance of alternative fuel (e.g., solid recovered fuel, SRF) in co-incineration plants--especially for inhomogeneous alternative fuels with large particle sizes (d95⩾100 mm), which will gain even more importance in the substitution of conventional fuels due to low production costs. Existing standards for sampling and sample preparation do not cover the challenges resulting from these kinds of materials. A possible approach to ensure quality monitoring is shown in the present contribution. For this, a specially manufactured, automated comminution and sample divider device was installed at a cement plant in Rohožnik. In order to prove its practical suitability with methods according to current standards, the sampling and sample preparation process were validated for alternative fuel with a grain size >30 mm (i.e., d95=approximately 100 mm), so-called 'Hotdisc SRF'. Therefore, series of samples were taken and analysed. A comparison of the analysis results with the yearly average values obtained through a reference investigation route showed good accordance. Further investigations during the validation process also showed that segregation or enrichment of material throughout the comminution plant does not occur. The results also demonstrate that compliance with legal standards regarding the minimum sample amount is not sufficient for inhomogeneous and coarse particle size alternative fuels. Instead, higher sample amounts after the first particle size reduction step are strongly recommended in order to gain a representative laboratory sample. © The Author(s) 2016.

  3. Interface unit

    NARCIS (Netherlands)

    Keyson, D.V.; Freudenthal, A.; De Hoogh, M.P.A.; Dekoven, E.A.M.

    2001-01-01

    The invention relates to an interface unit comprising at least a display unit for communication with a user, which is designed for being coupled with a control unit for at least one or more parameters in a living or working environment, such as the temperature setting in a house, which control unit

  4. Standard practice for sampling special nuclear materials in multi-container lots

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1987-01-01

    1.1 This practice provides an aid in designing a sampling and analysis plan for the purpose of minimizing random error in the measurement of the amount of nuclear material in a lot consisting of several containers. The problem addressed is the selection of the number of containers to be sampled, the number of samples to be taken from each sampled container, and the number of aliquot analyses to be performed on each sample. 1.2 This practice provides examples for application as well as the necessary development for understanding the statistics involved. The uniqueness of most situations does not allow presentation of step-by-step procedures for designing sampling plans. It is recommended that a statistician experienced in materials sampling be consulted when developing such plans. 1.3 The values stated in SI units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standar...

  5. Threshold-dependent sample sizes for selenium assessment with stream fish tissue

    Science.gov (United States)

    Hitt, Nathaniel P.; Smith, David R.

    2015-01-01

    Natural resource managers are developing assessments of selenium (Se) contamination in freshwater ecosystems based on fish tissue concentrations. We evaluated the effects of sample size (i.e., number of fish per site) on the probability of correctly detecting mean whole-body Se values above a range of potential management thresholds. We modeled Se concentrations as gamma distributions with shape and scale parameters fitting an empirical mean-to-variance relationship in data from southwestern West Virginia, USA (63 collections, 382 individuals). We used parametric bootstrapping techniques to calculate statistical power as the probability of detecting true mean concentrations up to 3 mg Se/kg above management thresholds ranging from 4 to 8 mg Se/kg. Sample sizes required to achieve 80% power varied as a function of management thresholds and Type I error tolerance (α). Higher thresholds required more samples than lower thresholds because populations were more heterogeneous at higher mean Se levels. For instance, to assess a management threshold of 4 mg Se/kg, a sample of eight fish could detect an increase of approximately 1 mg Se/kg with 80% power (given α = 0.05), but this sample size would be unable to detect such an increase from a management threshold of 8 mg Se/kg with more than a coin-flip probability. Increasing α decreased sample size requirements to detect above-threshold mean Se concentrations with 80% power. For instance, at an α-level of 0.05, an 8-fish sample could detect an increase of approximately 2 units above a threshold of 8 mg Se/kg with 80% power, but when α was relaxed to 0.2, this sample size was more sensitive to increasing mean Se concentrations, allowing detection of an increase of approximately 1.2 units with equivalent power. Combining individuals into 2- and 4-fish composite samples for laboratory analysis did not decrease power because the reduced number of laboratory samples was compensated for by increased

  6. Groundwater-quality data in the Klamath Mountains study unit, 2010: results from the California GAMA Program

    Science.gov (United States)

    Mathany, Timothy M.; Belitz, Kenneth

    2014-01-01

    Groundwater quality in the 8,806-square-mile Klamath Mountains (KLAM) study unit was investigated by the U.S. Geological Survey (USGS) from October to December 2010, as part of the California State Water Resources Control Board (SWRCB) Groundwater Ambient Monitoring and Assessment (GAMA) Program’s Priority Basin Project (PBP). The GAMA-PBP was developed in response to the California Groundwater Quality Monitoring Act of 2001 and is being conducted in collaboration with the SWRCB and Lawrence Livermore National Laboratory (LLNL). The KLAM study unit was the thirty-third study unit to be sampled as part of the GAMA-PBP. The GAMA Klamath Mountains study was designed to provide a spatially unbiased assessment of untreated-groundwater quality in the primary aquifer system and to facilitate statistically consistent comparisons of untreated-groundwater quality throughout California. The primary aquifer system is defined by the perforation intervals of wells listed in the California Department of Public Health (CDPH) database for the KLAM study unit. Groundwater quality in the primary aquifer system may differ from the quality in the shallower or deeper water-bearing zones; shallower groundwater may be more vulnerable to surficial contamination. In the KLAM study unit, groundwater samples were collected from sites in Del Norte, Siskiyou, Humboldt, Trinity, Tehama, and Shasta Counties, California. Of the 39 sites sampled, 38 were selected by using a spatially distributed, randomized grid-based method to provide statistical representation of the primary aquifer system in the study unit (grid sites), and the remaining site was non-randomized (understanding site). The groundwater samples were analyzed for basic field parameters, organic constituents (volatile organic compounds [VOCs] and pesticides and pesticide degradates), inorganic constituents (trace elements, nutrients, major and minor ions, total dissolved solids [TDS]), radon-222, gross alpha and gross beta

  7. Water-quality assessment of south-central Texas : comparison of water quality in surface-water samples collected manually and by automated samplers

    Science.gov (United States)

    Ging, Patricia B.

    1999-01-01

    Surface-water sampling protocols of the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program specify samples for most properties and constituents to be collected manually in equal-width increments across a stream channel and composited for analysis. Single-point sampling with an automated sampler (autosampler) during storms was proposed in the upper part of the South-Central Texas NAWQA study unit, raising the question of whether property and constituent concentrations from automatically collected samples differ significantly from those in samples collected manually. Statistical (Wilcoxon signed-rank test) analyses of 3 to 16 paired concentrations for each of 26 properties and constituents from water samples collected using both methods at eight sites in the upper part of the study unit indicated that there were no significant differences in concentrations for dissolved constituents, other than calcium and organic carbon.

  8. Assessment Of Nurses Performance During Cardiopulmonary Resuscitation In Intensive Care Unit And Cardiac Care Unit At The Alexandria Main University Hospital.

    Directory of Open Access Journals (Sweden)

    Dr. Nagla Hamdi Kamal Khalil El- Meanawi

    2015-08-01

    Full Text Available Abstract Background Cardiopulmonary resuscitation one of the most emergency management the nurse has a pivotal role and should be highly qualified in performing these procedures. The aim of the study is to assess performance of nurses during Cardio pulmonary resuscitation for patient with cardiac arrest In Intensive Care Unit and Cardiac Care Unit at the Alexandria main university hospital. To answer the question what are the most common area of satisfactory and area of neglection in nurses performance during Cardio Pulmonary Resuscitation. The sample consists of 53 staff nurses working in Intensive care unit amp cardiac care unit at Alexandria main university hospital. The tools of data collection were structured of questionnaire sheet and observational cheek list. The results showed that unsatisfactory performance between nurses in both units. The study concluded that all nurses need to improve their performance during cardiopulmonary resuscitation for patient with cardiac arrest it is crucial for nursing staff to participate in CPR courses in order to refresh and update their theoretical knowledge and performance skills and consequently to improve the safety and effectiveness of care. The study recommended that continuous evaluation of nurses knowledge and performance is essential the optimal frequency with which CPR training should be implemented at least every 6 months in order to avoid deterioration in nurses CPR knowledge and skills.

  9. Automatic setting of the distance between sample and detector in gamma-ray spectroscopy

    International Nuclear Information System (INIS)

    Andeweg, A.H.

    1980-01-01

    An apparatus has been developed that automatically sets the distance from the sample to the detector according to the radioactivity of the sample. The distance-setting unit works in conjuction with an automatic sample changer, and is interconnected with other components so that the counting head automatically moves to the optimum distance for the analysis of a particular sample. The distance, which is indicated digitally in increments of 0,01 mm, can be set between 18 and 995 mm at count rates that can be preset between 1000 and 10 000 counts per second. On being tested, the instrument performed well within the desired range and accuracy. Under routine conditions, the spectra were much more accurate than before, especially when samples of different radioactivity were counted

  10. Determination of radioactivity concentrations in soil samples and dose assessment for Rize Province, Turkey

    Directory of Open Access Journals (Sweden)

    Ayşe Durusoy

    2017-10-01

    The activity concentrations of radionuclides in soil samples were compared to the international values reported by United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR, 2000 and previous studies on the area.

  11. Online mixted sampling: An application in hidden populations Muestreo mixto online: Una aplicación en poblaciones ocultas Online mixted sampling: An application in hidden populations

    Directory of Open Access Journals (Sweden)

    María Tatiana Gorjup

    2012-04-01

    inmigrante argentino y utilizando como fuentes de información los grupos virtuales.Purpose: The objective of the article is to explore the possibilities offered by new technologies and virtual social networks for the recruitment of sampling units in hidden populations and as a support of the use of mixed methods.Design/methodology: The objective was to identify Argentinean entrepreneurs who start their business in Spain. The observation unit has the characteristics of a hidden population: 1 high geographic dispersion which makes it difficult to localize them; 2 underestimation of the size of Argentinean residents in the official statistics; 3 Argentinean residents in illegal situation; and, 4 in some cases, the factors that led the emigration were negative, making them reluctant to answer. In this context, the researchers used (1 an online virtual sampling and, (2 the traditional snowball sampling. The online virtual sampling was carried out by using a social network (Facebook through which 52 virtual groups of ‘Argentinean living in Spain’ were identified. Subsequently, each member was contacted by an individual message which explained the aim of the research and invited them to participate in the study. Findings: Through the development of this study, it was possible to prove that the use of virtual groups in social networks led to detect observation units that are not registered officially (administrative register, census, etc.. This finding contributed to increase the scope and size of the sample, it favoured the design of the qualitative sample and the triangulation of the results. Therefore, it increased the validity of the hidden population.Originality/value: The article presents an experience of application of virtual sampling and mixed methods in the study of hidden populations. In particular, it analysed Argentinean immigrant entrepreneurs by using virtual groups as a source of information.Purpose: The objective of the article is to explore the possibilities

  12. Molecular surveillance of low pathogenic avian influenza viruses in wild birds across the United States: inferences from the hemagglutinin gene.

    Directory of Open Access Journals (Sweden)

    Antoinette J Piaggio

    Full Text Available A United States interagency avian influenza surveillance plan was initiated in 2006 for early detection of highly pathogenic avian influenza viruses (HPAIV in wild birds. The plan included a variety of wild bird sampling strategies including the testing of fecal samples from aquatic areas throughout the United States from April 2006 through December 2007. Although HPAIV was not detected through this surveillance effort we were able to obtain 759 fecal samples that were positive for low pathogenic avian influenza virus (LPAIV. We used 136 DNA sequences obtained from these samples along with samples from a public influenza sequence database for a phylogenetic assessment of hemagglutinin (HA diversity in the United States. We analyzed sequences from all HA subtypes except H5, H7, H14 and H15 to examine genetic variation, exchange between Eurasia and North America, and geographic distribution of LPAIV in wild birds in the United States. This study confirms intercontinental exchange of some HA subtypes (including a newly documented H9 exchange event, as well as identifies subtypes that do not regularly experience intercontinental gene flow but have been circulating and evolving in North America for at least the past 20 years. These HA subtypes have high levels of genetic diversity with many lineages co-circulating within the wild birds of North America. The surveillance effort that provided these samples demonstrates that such efforts, albeit labor-intensive, provide important information about the ecology of LPAIV circulating in North America.

  13. Nevada National Security Site Integrated Groundwater Sampling Plan, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Marutzky, Sam; Farnham, Irene

    2014-10-01

    The purpose of the Nevada National Security Site (NNSS) Integrated Sampling Plan (referred to herein as the Plan) is to provide a comprehensive, integrated approach for collecting and analyzing groundwater samples to meet the needs and objectives of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) Underground Test Area (UGTA) Activity. Implementation of this Plan will provide high-quality data required by the UGTA Activity for ensuring public protection in an efficient and cost-effective manner. The Plan is designed to ensure compliance with the UGTA Quality Assurance Plan (QAP). The Plan’s scope comprises sample collection and analysis requirements relevant to assessing the extent of groundwater contamination from underground nuclear testing. This Plan identifies locations to be sampled by corrective action unit (CAU) and location type, sampling frequencies, sample collection methodologies, and the constituents to be analyzed. In addition, the Plan defines data collection criteria such as well-purging requirements, detection levels, and accuracy requirements; identifies reporting and data management requirements; and provides a process to ensure coordination between NNSS groundwater sampling programs for sampling of interest to UGTA. This Plan does not address compliance with requirements for wells that supply the NNSS public water system or wells involved in a permitted activity.

  14. [Medication errors in Spanish intensive care units].

    Science.gov (United States)

    Merino, P; Martín, M C; Alonso, A; Gutiérrez, I; Alvarez, J; Becerril, F

    2013-01-01

    To estimate the incidence of medication errors in Spanish intensive care units. Post hoc study of the SYREC trial. A longitudinal observational study carried out during 24 hours in patients admitted to the ICU. Spanish intensive care units. Patients admitted to the intensive care unit participating in the SYREC during the period of study. Risk, individual risk, and rate of medication errors. The final study sample consisted of 1017 patients from 79 intensive care units; 591 (58%) were affected by one or more incidents. Of these, 253 (43%) had at least one medication-related incident. The total number of incidents reported was 1424, of which 350 (25%) were medication errors. The risk of suffering at least one incident was 22% (IQR: 8-50%) while the individual risk was 21% (IQR: 8-42%). The medication error rate was 1.13 medication errors per 100 patient-days of stay. Most incidents occurred in the prescription (34%) and administration (28%) phases, 16% resulted in patient harm, and 82% were considered "totally avoidable". Medication errors are among the most frequent types of incidents in critically ill patients, and are more common in the prescription and administration stages. Although most such incidents have no clinical consequences, a significant percentage prove harmful for the patient, and a large proportion are avoidable. Copyright © 2012 Elsevier España, S.L. and SEMICYUC. All rights reserved.

  15. Accuracy assessment of the National Forest Inventory map of Mexico: sampling designs and the fuzzy characterization of landscapes

    Directory of Open Access Journals (Sweden)

    Stéphane Couturier

    2009-10-01

    Full Text Available There is no record so far in the literature of a comprehensive method to assess the accuracy of regional scale Land Cover/ Land Use (LCLU maps in the sub-tropical belt. The elevated biodiversity and the presence of highly fragmented classes hamper the use of sampling designs commonly employed in previous assessments of mainly temperate zones. A sampling design for assessing the accuracy of the Mexican National Forest Inventory (NFI map at community level is presented. A pilot study was conducted on the Cuitzeo Lake watershed region covering 400 000 ha of the 2000 Landsat-derived map. Various sampling designs were tested in order to find a trade-off between operational costs, a good spatial distribution of the sample and the inclusion of all scarcely distributed classes (‘rare classes’. A two-stage sampling design where the selection of Primary Sampling Units (PSU was done under separate schemes for commonly and scarcely distributed classes, showed best characteristics. A total of 2 023 punctual secondary sampling units were verified against their NFI map label. Issues regarding the assessment strategy and trends of class confusions are devised.

  16. Use of Physio-Hydrological Units for SMOS Validation at the Valencia Anchor Station Study Area

    Science.gov (United States)

    Millán-Scheiding, C.; Antolín, C.; Marco, J.; Soriano, M. P.; Torre, E.; Requena, F.; Carbó, E.; Cano, A.; Lopez-Baeza, E.

    2009-04-01

    The SMOS space mission will soil moisture over the continents and ocean surface salinity with the sufficient resolution to be used in global climate change studies. With the aim of validating SMOS land data and products at the Valencia Anchor Station site (VAS) in a Mediterranean Ecosystem area of Spain, we have designed a sample methodology using a subdivision of the landscape in environmental units related to the spatial variability of soil moisture (Millán-Scheiding, 2006; Lopez-Baeza, et al. 2008). These physio-hydrological units are heterogeneously structured entities which present a certain degree of internal uniformity of hydrological parameters. The units are delimited by integrating areas with the same physio-morphology, soil type, vegetation, geology and topography (Flugel, et al 2003; Millán-Scheiding et al, 2007). Each of these units presented over the same pedological characteristics, vegetation cover, and landscape position should have a certain degree of internal uniformity in its hydrological parameters and therefore similar soil moisture (SM). The main assumption for each unit is that the dynamical variation of the hydrological parameters within one unit should be minimum compared to the dynamics of another unit. This methodology will hopefully provide an effective sampling design consisting of a reduced number of measuring points, sparsely distributed over the area, or alternatively, using SM validation networks where each sampling point is located where it is representative of the mean soil moisture of a complete unit area. The Experimental Plan for the SMOS Validation Rehearsal Campaign at the VAS area of April-May 2008 used this environmental subdivision in the selection and sampling of over 21.000 soil moisture points in a control area of 10 x 10 km2. The ground measurements were carried out during 4 nights corresponding to a drying out period of the soil. The sampling consisted of 700 plots with 4 volumetric SM cylinders and 7 Delta-T Theta

  17. Mercury contamination in bats from the central United States.

    Science.gov (United States)

    Korstian, Jennifer M; Chumchal, Matthew M; Bennett, Victoria J; Hale, Amanda M

    2018-01-01

    Mercury (Hg) is a highly toxic metal that has detrimental effects on wildlife. We surveyed Hg concentrations in 10 species of bats collected at wind farms in the central United States and found contamination in all species. Mercury concentration in fur was highly variable both within and between species (range: 1.08-10.52 µg/g). Despite the distance between sites (up to 1200 km), only 2 of the 5 species sampled at multiple locations had fur Hg concentrations that differed between sites. Mercury concentrations observed in the present study all fell within the previously reported ranges for bats collected from the northeastern United States and Canada, although many of the bats we sampled had lower maximum Hg concentrations. Juvenile bats had lower concentrations of Hg in fur compared with adult bats, and we found no significant effect of sex on Hg concentrations in fur. For a subset of 2 species, we also measured Hg concentration in muscle tissue; concentrations were much higher in fur than in muscle, and Hg concentrations in the 2 tissue types were weakly correlated. Abundant wind farms and ongoing postconstruction fatality surveys offer an underutilized opportunity to obtain tissue samples that can be used to assess Hg contamination in bats. Environ Toxicol Chem 2018;37:160-165. © 2018 SETAC. © 2017 SETAC.

  18. Parental involvement and kangaroo care in European neonatal intensive care units

    DEFF Research Database (Denmark)

    Pallás-Alonso, Carmen R; Losacco, Valentina; Maraschini, Alice

    2012-01-01

    To compare, in a large representative sample of European neonatal intensive care units, the policies and practices regarding parental involvement and holding babies in the kangaroo care position as well as differences in the tasks mothers and fathers are allowed to carry out....

  19. Strain, negative emotions, and juvenile delinquency: the United States versus taiwan.

    Science.gov (United States)

    Lin, Wen-Hsu; Dembo, Richard; Sellers, Christine S; Cochran, John; Mieczkowski, Thomas

    2014-04-01

    General strain theory (GST) is an established criminological theory. Although the theory has been examined by many and enjoys empirical support, some limitations of previous studies need to be addressed. Many previous studies rely heavily on samples from Western countries, mostly the United States; thus, possible cultural influences are ignored. Although a few studies have moved forward by using subjects from Asia (e.g., China, Korea), these studies only provide empirical results regarding whether GST is applicable in other cultures. However, these studies do not directly compare Western and Eastern countries. The present study used two samples from the United States and Taiwan to directly compare and contrast central GST propositions. Although most of the GST propositions are found to be similar between the U.S. and Taiwanese juveniles, some differences were also discovered. Explanation of these similarities and differences from their cultural perspectives are offered in this study.

  20. Possible conservation units of the sun bear (Helarctos malayanus) in Sarawak based on variation of mtDNA control region.

    Science.gov (United States)

    Onuma, Manabu; Suzuki, Masatsugu; Ohtaishi, Noriyuki

    2006-11-01

    The mitochondrial DNA control region of the sun bear (Helarctos malayanus) was sequenced using 21 DNA samples collected from confiscated sun bears to identify conservation units, such as evolutionarily significant units and management units, in Sarawak, Borneo Island. A total of 10 haplotypes were observed, indicating the presence of at least two lineages in the sun bear population in Sarawak. Presumably, these two lineages could represent evolutionarily significant units. However, the geographical distributions of the two lineages remained unknown due to the lack of information regarding the exact capture locations of the confiscated sun bears. It is essential to elucidate the geographical distributions of these lineages in order to create a proper conservation plan for the sun bears in Sarawak. Therefore, further studies examining the haplotype distributions using DNA samples from known localities are essential.

  1. Longitudinal effects of violent video games on aggression in Japan and the United States.

    Science.gov (United States)

    Anderson, Craig A; Sakamoto, Akira; Gentile, Douglas A; Ihori, Nobuko; Shibuya, Akiko; Yukawa, Shintaro; Naito, Mayumi; Kobayashi, Kumiko

    2008-11-01

    Youth worldwide play violent video games many hours per week. Previous research suggests that such exposure can increase physical aggression. We tested whether high exposure to violent video games increases physical aggression over time in both high- (United States) and low- (Japan) violence cultures. We hypothesized that the amount of exposure to violent video games early in a school year would predict changes in physical aggressiveness assessed later in the school year, even after statistically controlling for gender and previous physical aggressiveness. In 3 independent samples, participants' video game habits and physically aggressive behavior tendencies were assessed at 2 points in time, separated by 3 to 6 months. One sample consisted of 181 Japanese junior high students ranging in age from 12 to 15 years. A second Japanese sample consisted of 1050 students ranging in age from 13 to 18 years. The third sample consisted of 364 United States 3rd-, 4th-, and 5th-graders ranging in age from 9 to 12 years. RESULTS. Habitual violent video game play early in the school year predicted later aggression, even after controlling for gender and previous aggressiveness in each sample. Those who played a lot of violent video games became relatively more physically aggressive. Multisample structure equation modeling revealed that this longitudinal effect was of a similar magnitude in the United States and Japan for similar-aged youth and was smaller (but still significant) in the sample that included older youth. These longitudinal results confirm earlier experimental and cross-sectional studies that had suggested that playing violent video games is a significant risk factor for later physically aggressive behavior and that this violent video game effect on youth generalizes across very different cultures. As a whole, the research strongly suggests reducing the exposure of youth to this risk factor.

  2. Molecular Detection of Avian Influenza Virus from Sediment Samples in Waterfowl Habitats on the Delmarva Peninsula, United States.

    Science.gov (United States)

    Densmore, C L; Iwanowicz, D D; Ottinger, C A; Hindman, L J; Bessler, A M; Iwanowicz, L R; Prosser, D J; Whitbeck, M; Driscoll, C P

    2017-12-01

    Avian influenza viruses (AIV) affect many species of birds including waterfowl and may persist in sediment in aquatic habitats. Sediment samples were collected from two areas representative of prime migration and overwintering waterfowl habitat in Dorchester County, Maryland in the fall and winter of 2013-2014. Samples were screened for the presence of AIV via reverse transcriptase-quantitative PCR targeting the matrix gene. Although 13.6% of sediment samples were positive for the AIV matrix gene across all collection dates and locations, differences in detection were noted with location and collection season. Percentage of AIV-positive sediment samples recovered corresponded to trends in waterfowl abundance at collection sites both temporally and spatially. These findings provide further support for the assertion that the presence of AIV in the aquatic environment is likely affected by the total number, site-specific density, and array of waterfowl species.

  3. An automatic control unit for A neutron diffraction crystal spectrometer

    International Nuclear Information System (INIS)

    Adib, M.; Abbas, Y.; Mostafa, M.; Hamouda, I.

    1982-01-01

    An automatic transistorized unit has been designed and constructed to control the operation of the double axis crystal spectrometer installed in front of one of the horizontal channels of the ET-RR-1 reactor. The function of the automatic unit is to store the diffracted neutrons at a certain angle with respect to the direction of the incident neutron beam in a selected channel of a 1024-multichannel analyzer for a certain preadjusted time period. AT the end of this time period the unit rotates the spectrometer's arm to another angle, selects the next channel of the MCA and provides the measurement of the diffracted neutron for the same time period. Such a sequence is repeated automatically over all angles required for the neutron diffraction pattern of the sample under investigation. As a result, the stored information at the MCA provides the neutron diffraction pattern as a function of channel number, where each channel corresponds to a certain scattering angle. The stored distribution at MCA can be obtained through the analyzer read out unit. The designed automatic unit has the possibility of providing the neutron diffraction pattern using a 6-digit scaler and a printer

  4. SALTSTONE VAULT CLASSIFICATION SAMPLES MODULAR CAUSTIC SIDE SOLVENT EXTRACTION UNIT/ACTINIDE REMOVAL PROCESS WASTE STREAM APRIL 2011

    Energy Technology Data Exchange (ETDEWEB)

    Eibling, R.

    2011-09-28

    Savannah River National Laboratory (SRNL) was asked to prepare saltstone from samples of Tank 50H obtained by SRNL on April 5, 2011 (Tank 50H sampling occurred on April 4, 2011) during 2QCY11 to determine the non-hazardous nature of the grout and for additional vault classification analyses. The samples were cured and shipped to Babcock & Wilcox Technical Services Group-Radioisotope and Analytical Chemistry Laboratory (B&W TSG-RACL) to perform the Toxic Characteristic Leaching Procedure (TCLP) and subsequent extract analysis on saltstone samples for the analytes required for the quarterly analysis saltstone sample. In addition to the eight toxic metals - arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver - analytes included the underlying hazardous constituents (UHC) antimony, beryllium, nickel, and thallium which could not be eliminated from analysis by process knowledge. Additional inorganic species determined by B&W TSG-RACL include aluminum, boron, chloride, cobalt, copper, fluoride, iron, lithium, manganese, molybdenum, nitrate/nitrite as Nitrogen, strontium, sulfate, uranium, and zinc and the following radionuclides: gross alpha, gross beta/gamma, 3H, 60Co, 90Sr, 99Tc, 106Ru, 106Rh, 125Sb, 137Cs, 137mBa, 154Eu, 238Pu, 239/240Pu, 241Pu, 241Am, 242Cm, and 243/244Cm. B&W TSG-RACL provided subsamples to GEL Laboratories, LLC for analysis for the VOCs benzene, toluene, and 1-butanol. GEL also determines phenol (total) and the following radionuclides: 147Pm, 226Ra and 228Ra. Preparation of the 2QCY11 saltstone samples for the quarterly analysis and for vault classification purposes and the subsequent TCLP analyses of these samples showed that: (1) The saltstone waste form disposed of in the Saltstone Disposal Facility in 2QCY11 was not characteristically hazardous for toxicity. (2) The concentrations of the eight RCRA metals and UHCs identified as possible in the saltstone waste form were present at levels below the UTS. (3) Most of the

  5. Units of measurement past, present and future international system of units

    CERN Document Server

    Gupta, S V

    2010-01-01

    It is for the first time that the subject of quantities and their respective units is dealt this much in detail a glimpse of units of measurements of base quantities of length, time, mass and volume is given for ancient India three and four dimensional systems of measurement units are critically examined establishment of the fact that only four base units are needed to describe a system of units the basics to arrive at the unit of a derived quantity are explained basic, derived and dimensionless quantities including quantity calculus are introduced life history of scientists concerned with measurements units are presented to be inspiring to working metrologists and students. The International System of Units including, Metre Convention Treaty and its various organs including International National of Weights and Measure are described. The realisation of base units is given in detail. Classes of derived units within the SI, units permitted for time to come, units outside SI but used in special fields of measur...

  6. Coronary Atherectomy in the United States (from a Nationwide Inpatient Sample).

    Science.gov (United States)

    Arora, Shilpkumar; Panaich, Sidakpal S; Patel, Nilay; Patel, Nileshkumar J; Savani, Chirag; Patel, Samir V; Thakkar, Badal; Sonani, Rajesh; Jhamnani, Sunny; Singh, Vikas; Lahewala, Sopan; Patel, Achint; Bhatt, Parth; Shah, Harshil; Jaiswal, Radhika; Gupta, Vishal; Deshmukh, Abhishek; Kondur, Ashok; Schreiber, Theodore; Badheka, Apurva O; Grines, Cindy

    2016-02-15

    Contemporary real-world data on clinical outcomes after utilization of coronary atherectomy are sparse. The study cohort was derived from Healthcare Cost and Utilization Project Nationwide Inpatient Sample database from year 2012. Percutaneous coronary interventions including atherectomy were identified using appropriate International Classification of Diseases, 9th Revision diagnostic and procedural codes. Two-level hierarchical multivariate mixed models were created. The primary outcome was a composite of in-hospital mortality and periprocedural complications; the secondary outcome was in-hospital mortality. Hospitalization costs were also assessed. A total of 107,131 procedures were identified in 2012. Multivariate analysis revealed that atherectomy utilization was independently predictive of greater primary composite outcome of in-hospital mortality and complications (odds ratio 1.34, 95% confidence interval 1.22 to 1.47, p atherectomy utilization was again associated with a higher rate of complications (12.88% vs 10.99%, p = 0.001), in-hospital mortality +a ny complication (13.69% vs 11.91%, p = 0.003) with a nonsignificant difference in terms of in-hospital mortality alone (3.45% vs 2.88%, p = 0.063) and higher hospitalization costs ($25,341 ± 353 vs $21,984 ± 87, p Atherectomy utilization during percutaneous coronary intervention is associated with a higher rate of postprocedural complications without any significant impact on in-hospital mortality. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Study of the efficiency of some water treatment unit that present in houses in Erbil city-Iraq

    Science.gov (United States)

    Toma, Janan. Jabbar.; Hanna, Aveen. Matti.

    2017-09-01

    Many people in Erbil city started more than two decade to put special treatment units in their houses to purified water to become safer for drinking uses. The aim of this study was determine the efficiency of six kind water treatment units which include (two replicate of Crystal Water Purifier, So-Safe Water Filter, R O Water Purifier, Kontec Water Purified and Al-Kawther Purified Water). Water samples were collected in two sites one before and other after treatment unit. Each sample was collect with three replication during May to October-2016. Analyzed for Major cations concentration (calcium, magnesium, sodium and potassium), anions concentration (nitrate and chloride) and hydrogen ion concentration (pH), electrical conductivity (EC), total dissolved solids (TDS), alkalinity and total hardness by using standard methods. The water quality index values for all raw water sample befor and after treatment was good and excellent respectively for drinking purposes. Efficiency of So-Safe Water Filter was 66.32% it means was more efficiency than others special water treatment units while in RO Water Purifier was 27.14%, means less efficiency than other water purifier water under this study. Values for major cations, anions and others chemicals characteristics in the water samples after treatment became lower concentrations than befor treatment, likely an indication that these were removed by treatment. According to guideline of world health organization all of variables except total hardness befor treatment are safe and suitable for drinking purposes.

  8. Unitized solid phase immunoassay kit and method

    International Nuclear Information System (INIS)

    1975-01-01

    A unitized solid phase kit for radioimmunoassay is disclosed. All of the necessary assay reagents are incorporated into a single tube wherein all phases of the assay procedure are performed, requiring only the addition of the patient's sample. Antibody is bound to the tube surface while labelled antigen is also present but unbound. Storage in the absence of air and water results in the stabilization of the reagents such that the system can be stored for long periods

  9. Efektivitas Unit Produksi sebagai Sumber Belajar Kewirausahaan di SMK Kota Yogyakarta

    Directory of Open Access Journals (Sweden)

    Yuliansah Yuliansah

    2016-01-01

    Full Text Available The objective of this study was to determine how production units can be used effectively as an entreprenuership learning resource to increase the entrepreneurial learning motivation, to clarify the content of the entrepreneurial learning materials and to provide direct experiences for the Vocational High Schools students in Yogyakarta. This study is survey research with quantitative approach. The population of this study were 1.995 students of grade XI and grade XII at 17 Vocational High School in Yogyakarta. 333 students were selected as the sample. Questionnaires and documentation were used for collecting the data. The data was analysed through quantitative descriptive analysis using the Microsoft Excel software. The result of this study indicated that: (1 Production units were effective to increase the intrinsic entrepreneurial learning motivation of the students (2 Production units were ineffective to increase the extrinsic entrepreneurial learning motivation of the students (3 Production units were ineffective to clarify the entrepreneurial learning materials (4 Production units were ineffective to provide direct experiences for the students.

  10. A qualitative study of work-life balance amongst specialist orthodontists in the United Kingdom

    OpenAIRE

    Cunningham, S. J.; Bateman, L. E.; Collins, J. M.

    2016-01-01

    Objective: To identify factors affecting work-life balance amongst male and female orthodontists in the United Kingdom. Design: A qualitative interview-based study with a cross-sectional design. Subjects: Specialist orthodontists working in specialist practice and the hospital service in the United Kingdom were selected by purposive sampling. Methods: In-depth semi-structured interviews were conducted with eighteen orthodontic specialists. Interview transcripts were analysed using Framework A...

  11. Sampling and Analysis Plan for N-Springs ERA pump-and-treat waste media

    International Nuclear Information System (INIS)

    Stankovich, M.T.

    1996-07-01

    This Sampling and Analysis Plan details the administrative procedures to be used to conduct sampling activities for characterization of spent ion-exchange resin, clinoptilolite, generated from the N-Springs pump-and-treat expedited response action. N-Springs (riverbank seeps) is located in the 100-N Area of the Hanford Site. Groundwater contained in the 100-NR-2 Operable Unit is contaminated with various radionuclides derived from wastewater disposal practices and spills associated with 100-N Reactor Operations

  12. Delineating demographic units of woodland caribou (Rangifer tarandus caribou in Ontario: cautions and insights

    Directory of Open Access Journals (Sweden)

    Jennifer L. Shuter

    2012-03-01

    Full Text Available Delineating demographic structure across an organism’s range can reveal the extent to which population dynamics in different geographic areas are driven by local or external factors and can be crucial for effective conservation and management. Obtaining optimal data for such analyses can be time and resource-intensive and impending development and resource extraction pressures may necessitate the examination of existing data, even when they are less than ideal. We analyzed a historic telemetry dataset containing satellite radio-collar locations of 73 forest-dwelling woodland caribou in northern Ontario to determine demographic structure. We applied several clustering methods (i.e., agglomerative, divisive and fuzzy k-means to median seasonal locations. Results were used to distinguish demographic units and minimum convex polygons and fixed-kernel density estimates were used to delineate unit boundaries and core areas. For areas where sampling was considered representative of the distribution of caribou on the landscape, we assessed demographic distinctness by evaluating intra-individual variation in cluster membership, membership strength and distance between boundaries and core areas of adjacent units. The number and composition of clusters identified was similar among methods and caribou were grouped into 6 general clusters. The distinctions between the three clusters identified in the central portion of the province (i.e., Lac Seul, Wabakimi, Geraldton and the two clusters identified in the eastern portion of the province (i.e., Cochrane and Cochrane-Quebec were determined to represent demographic structuring. Additional distinctions in other areas (i.e., between The Red Lake and Lac Seul clusters in the west and between the central and eastern clusters may just be artifacts of the original sampling effort. Amongst demographic units, there was no evidence of individual flexibility in cluster membership and average membership strength was

  13. Streamlined Approach for Environmental Restoration Work Plan for Corrective Action Unit 461: Joint Test Assembly Sites and Corrective Action Unit 495: Unconfirmed Joint Test Assembly Sites Tonopah Test Range, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Jeff Smith

    1998-08-01

    This Streamlined Approach for Environmental Restoration plan addresses the action necessary for the clean closure of Corrective Action Unit 461 (Test Area Joint Test Assembly Sites) and Corrective Action Unit 495 (Unconfirmed Joint Test Assembly Sites). The Corrective Action Units are located at the Tonopah Test Range in south central Nevada. Closure for these sites will be completed by excavating and evaluating the condition of each artillery round (if found); detonating the rounds (if necessary); excavating the impacted soil and debris; collecting verification samples; backfilling the excavations; disposing of the impacted soil and debris at an approved low-level waste repository at the Nevada Test Site

  14. 200-UP-2 Operable Unit technical baseline report

    International Nuclear Information System (INIS)

    Deford, D.H.

    1991-02-01

    This report is prepared in support of the development of a Remedial Investigation/Feasibility Study (RI/FS) Work Plan for the 200-UP-2 Operable Unit by EBASCO Environmental, Incorporated. It provides a technical baseline of the 200-UP-2 Operable Unit and results from an environmental investigation undertaken by the Technical Baseline Section of the Environmental Engineering Group, Westinghouse Hanford Company (Westinghouse Hanford). The 200-UP-2 Operable Unit Technical Baseline Report is based on review and evaluation of numerous Hanford Site current and historical reports, Hanford Site drawings and photographs and is supplemented with Hanford Site inspections and employee interviews. No field investigations or sampling were conducted. Each waste site in the 200-UP-2 Operable Unit is described separately. Close relationships between waste units, such as overflow from one to another, are also discussed. The 200-UP-2 Operable Unit consists of liquid-waste disposal sites in the vicinity of, and related to, U Plant operations in the 200 West Area of the Hanford Site. The ''U Plant'' refers to the 221-U Process Canyon Building, a chemical separations facility constructed during World War 2. It also includes the Uranium Oxide (UO 3 ) Plant, which was constructed at the same time and, like the 221-U Process Canyon Building, was later converted for other missions. Waste sites in the 200-UP-2 Operable Unit are associated with the U Plant Uranium Metal Recovery Program mission that occurred between 1952 and 1958 and the UO 3 Plant's ongoing uranium oxide mission and include one or more cribs, reverse wells, french drains, septic tanks and drain fields, trenches, catch tanks, settling tanks, diversion boxes, waste vaults, and the lines and encasements that connect them. 11 refs., 1 tab

  15. The Beautiful Brain: A Unit for Grades 5-9 with Further Explorations for Gifted and Talented.

    Science.gov (United States)

    Struve, Nancy

    The unit provides information on the study of the human brain for students in grades 5-9 with suggestions for extending the lessons for gifted and talented students. Learning activities are offered for ten lessons (sample subtopics in parentheses); introduction to the unit (student pretest and posttest); brain growth; medulla-oblongata-reptilian…

  16. Corrective Action Investigation Plan for Corrective Action Unit 428: Area 3 Septic Waste Systems 1 and 5, Tonopah Test Range, Nevada

    International Nuclear Information System (INIS)

    ITLV

    1999-01-01

    The Corrective Action Investigation Plan for Corrective Action Unit 428, Area 3 Septic Waste Systems 1 and 5, has been developed in accordance with the Federal Facility Agreement and Consent Order that was agreed to by the U. S. Department of Energy, Nevada Operations Office; the State of Nevada Division of Environmental Protection; and the U. S. Department of Defense. Corrective Action Unit 428 consists of Corrective Action Sites 03- 05- 002- SW01 and 03- 05- 002- SW05, respectively known as Area 3 Septic Waste System 1 and Septic Waste System 5. This Corrective Action Investigation Plan is used in combination with the Work Plan for Leachfield Corrective Action Units: Nevada Test Site and Tonopah Test Range, Nevada , Rev. 1 (DOE/ NV, 1998c). The Leachfield Work Plan was developed to streamline investigations at leachfield Corrective Action Units by incorporating management, technical, quality assurance, health and safety, public involvement, field sampling, and waste management information common to a set of Corrective Action Units with similar site histories and characteristics into a single document that can be referenced. This Corrective Action Investigation Plan provides investigative details specific to Corrective Action Unit 428. A system of leachfields and associated collection systems was used for wastewater disposal at Area 3 of the Tonopah Test Range until a consolidated sewer system was installed in 1990 to replace the discrete septic waste systems. Operations within various buildings at Area 3 generated sanitary and industrial wastewaters potentially contaminated with contaminants of potential concern and disposed of in septic tanks and leachfields. Corrective Action Unit 428 is composed of two leachfield systems in the northern portion of Area 3. Based on site history collected to support the Data Quality Objectives process, contaminants of potential concern for the site include oil/ diesel range total petroleum hydrocarbons, and Resource Conservation

  17. Thermal unit availability modeling in a regional simulation model

    International Nuclear Information System (INIS)

    Yamayee, Z.A.; Port, J.; Robinett, W.

    1983-01-01

    The System Analysis Model (SAM) developed under the umbrella of PNUCC's System Analysis Committee is capable of simulating the operation of a given load/resource scenario. This model employs a Monte-Carlo simulation to incorporate uncertainties. Among uncertainties modeled is thermal unit availability both for energy simulation (seasonal) and capacity simulations (hourly). This paper presents the availability modeling in the capacity and energy models. The use of regional and national data in deriving the two availability models, the interaction between the two and modifications made to the capacity model in order to reflect regional practices is presented. A sample problem is presented to show the modification process. Results for modeling a nuclear unit using NERC-GADS is presented

  18. Sampled data CT system including analog filter and compensating digital filter

    International Nuclear Information System (INIS)

    Glover, G. H.; DallaPiazza, D. G.; Pelc, N. J.

    1985-01-01

    A CT scanner in which the amount of x-ray information acquired per unit time is substantially increased by using a continuous-on x-ray source and a sampled data system with the detector. An analog filter is used in the sampling system for band limiting the detector signal below the highest frequency of interest, but is a practically realizable filter and is therefore non-ideal. A digital filter is applied to the detector data after digitization to compensate for the characteristics of the analog filter, and to provide an overall filter characteristic more nearly like the ideal

  19. Acinetobacter Infection and Resistance Profile of Intensive Care Units In a City of Northwestern Anatolia

    Directory of Open Access Journals (Sweden)

    İsa Yıldız

    2016-09-01

    Full Text Available INTRODUCTION: Determination of suitable antibiotics in treatment of Acinetobacter infections is through the hospital ascertaining the resistance state to bacteria causing the problem. In this study, the evaluation of antibiotics sensitivity of Acinetobacter strains isolated as infection factor in patients hospitalized in intensive care units is aimed. METHODS: Acinetobacter strains isolated from the samples of patients hospitalized in the 2nd and 3rd Stage adult intensive care units of a province in in northwestern Anatolia have been studied. RESULTS: A total of 165 patients were included in the study. The most isolated samples were respiratory tract samples, blood and urine. The antibiotics which the factors were most sensitive were cholistin (66,1% gentamicin (22,4% and trimethoprim sulfamethoxazole (18,2%. DISCUSSION AND CONCLUSION: We face increasing resistance ratios in Acinetobacter strains. Necessary precautions should be taken for this.

  20. Visual Sample Plan (VSP) Software: Designs and Data Analyses for Sampling Contaminated Buildings

    International Nuclear Information System (INIS)

    Pulsipher, Brent A.; Wilson, John E.; Gilbert, Richard O.; Nuffer, Lisa L.; Hassig, Nancy L.

    2005-01-01

    A new module of the Visual Sample Plan (VSP) software has been developed to provide sampling designs and data analyses for potentially contaminated buildings. An important application is assessing levels of contamination in buildings after a terrorist attack. This new module, funded by DHS through the Combating Terrorism Technology Support Office, Technical Support Working Group, was developed to provide a tailored, user-friendly and visually-orientated buildings module within the existing VSP software toolkit, the latest version of which can be downloaded from http://dqo.pnl.gov/vsp. In case of, or when planning against, a chemical, biological, or radionuclide release within a building, the VSP module can be used to quickly and easily develop and visualize technically defensible sampling schemes for walls, floors, ceilings, and other surfaces to statistically determine if contamination is present, its magnitude and extent throughout the building and if decontamination has been effective. This paper demonstrates the features of this new VSP buildings module, which include: the ability to import building floor plans or to easily draw, manipulate, and view rooms in several ways; being able to insert doors, windows and annotations into a room; 3-D graphic room views with surfaces labeled and floor plans that show building zones that have separate air handing units. The paper will also discuss the statistical design and data analysis options available in the buildings module. Design objectives supported include comparing an average to a threshold when the data distribution is normal or unknown, and comparing measurements to a threshold to detect hotspots or to insure most of the area is uncontaminated when the data distribution is normal or unknown

  1. How serious a problem is subsoil compaction in the Netherlands? A survey based on probability sampling

    Science.gov (United States)

    Brus, Dick J.; van den Akker, Jan J. H.

    2018-02-01

    Although soil compaction is widely recognized as a soil threat to soil resources, reliable estimates of the acreage of overcompacted soil and of the level of soil compaction parameters are not available. In the Netherlands data on subsoil compaction were collected at 128 locations selected by stratified random sampling. A map showing the risk of subsoil compaction in five classes was used for stratification. Measurements of bulk density, porosity, clay content and organic matter content were used to compute the relative bulk density and relative porosity, both expressed as a fraction of a threshold value. A subsoil was classified as overcompacted if either the relative bulk density exceeded 1 or the relative porosity was below 1. The sample data were used to estimate the means of the two subsoil compaction parameters and the overcompacted areal fraction. The estimated global means of relative bulk density and relative porosity were 0.946 and 1.090, respectively. The estimated areal fraction of the Netherlands with overcompacted subsoils was 43 %. The estimates per risk map unit showed two groups of map units: a low-risk group (units 1 and 2, covering only 4.6 % of the total area) and a high-risk group (units 3, 4 and 5). The estimated areal fraction of overcompacted subsoil was 0 % in the low-risk unit and 47 % in the high-risk unit. The map contains no information about where overcompacted subsoils occur. This was caused by the poor association of the risk map units 3, 4 and 5 with the subsoil compaction parameters and subsoil overcompaction. This can be explained by the lack of time for recuperation.

  2. Analytical results from salt batch 9 routine DSSHT and SEHT monthly samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-01

    Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 9 have been analyzed for 238Pu, 90Sr, 137Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Cs removal continues to be acceptable, with decontamination factors (DF) averaging 25700 (107% RSD). The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior, other than lacking the anticipated degree of dilution that is calculated to occur during Modular Caustic-Side Solvent Extraction Unit (MCU) processing.

  3. Unit and internal chain profiles of maca amylopectin.

    Science.gov (United States)

    Zhang, Ling; Li, Guantian; Yao, Weirong; Zhu, Fan

    2018-03-01

    Unit chain length distributions of amylopectin and its φ, β-limit dextrins, which reflect amylopectin internal structure from three maca starches, were determined by high-performance anion-exchange chromatography with pulsed amperometric detection after debranching, and the samples were compared with maize starch. The amylopectins exhibited average chain lengths ranging from 16.72 to 17.16, with ranges of total internal chain length, external chain length, and internal chain length of the maca amylopectins at 12.49 to 13.68, 11.24 to 11.89, and 4.27 to 4.48. The average chain length, external chain length, internal chain length, and total internal chain length were comparable in three maca amylopectins. Amylopectins of the three maca genotypes studied here presented no significant differences in their unit chain length profiles, but did show significant differences in their internal chain profiles. Additional genetic variations between different maca genotypes need to be studied to provide unit- and internal chain profiles of maca amylopectin. Copyright © 2017. Published by Elsevier Ltd.

  4. Gamma ray spectrometry results from core samples collected for RESUME 95

    International Nuclear Information System (INIS)

    Sanderson, D.C.W.; Allyson, J.D.; Toivonen, H.; Honkamaa, T.

    1997-01-01

    Field sampling of an airfield at Vesivehmaa, near Vaeaeksy, Finland (Area I) was carried out between 26-29 May 1995, to establish the radionuclide deposition and inventory of Chernobyl derived 137 Cs, and natural radionuclides. The objective was to establish a common calibration site for in-situ and airborne gamma spectrometers, for Exercise RESUME 95 conducted in August 1995. The report presents the sampling details, handling and treatment. The analyses are discussed with particular emphasis given to 137 Ca, 134 Cs, 40 K, 214 Bi and 208 radionuclides, and the quantification of their respective deposition and inventories. The results have been used to estimate the effective concentrations of nuclides at the calibration site for in-situ and airborne gamma spectrometry, and the depth distribution. For 137 Cs the weighted mean activity per unit area takes on values of 50.7±5.2 kBq m -2 at 1 m ground clearance, 51.1±6.9 kBq m -2 at 50 m height and 47.9±8.5 kBq m -2 at 100 m. The similarity of these values confirms the suitability of the Vesivehmaa site for comparison of in-situ and airborne results despite variations of a factor of two between results from individual cores. The mean α/ρ value for 137 Cs in Area I is 0.77±0.10 cm 2 g -1 (relaxation mass per unit area, β 1.31±0.15 gcm -2 ). Additional soil sampling across parts of Area II (a 6x3 km area selected for mapping Chernobyl deposition) was carried out. The mean level of 137 Cs activity from these samples was 92.4±63 kBq m -2 , a sample taken near Laihansuo showing the largest value obtained at 172 kBq m -2 . (EG)

  5. Automated cleaning of fan coil units with a natural detergent-disinfectant product

    Directory of Open Access Journals (Sweden)

    Di Onofrio Valeria

    2010-10-01

    Full Text Available Abstract Background Air conditioning systems represent one important source of microbial pollutants for indoor air. In the past few years, numerous strategies have been conceived to reduce the contamination of air conditioners, mainly in hospital settings. The biocidal detergent BATT2 represents a natural product obtained through extraction from brown seaweeds, that has been tested previously on multidrug-resistant microorganisms. Methods BATT2 has been utilized for the disinfection of fan coil units from four air conditioning systems located in hospital environments with a mean degree of risk. Samples were collected from the air supplied by the conditioning systems and from the surfaces of fan coil units, before and after sanitization procedures. Total microbial counts at 37°C and 22°C and mycotic count at 32°C were evaluated. Staphylococci and Pseudomonas aeruginosa were also detected on surfaces samples. Results The biodetergent was able to reduce up 50% of the microbial pollution of fan coil units surfaces and air supplied by the air conditioners. Conclusions BATT2 could be considered for cleaning/disinfection of air conditioning systems, that should be performed on the basis of accurate and verifiable sanitization protocols.

  6. Results of toxicity tests and chemical analyses conducted on sediments collected from the TNX Outfall Delta Operable Unit, July 1999

    International Nuclear Information System (INIS)

    Specht, W.L.

    2000-01-01

    In order to provide unit specific toxicity data that will be used to address critical uncertainty in the ecological risk assessment (ERA) for the TNX Outfall Delta Operable Unit (TNXOD OU), sediments were collected from eight locations in the Inner Swamp portion of the operable unit and two unit specific background locations. These samples were analyzed for total mercury, total uranium, and sediment toxicity

  7. Role of impact cratering for Mars sample return

    International Nuclear Information System (INIS)

    Schultz, P.H.

    1988-01-01

    The preserved cratering record of Mars indicates that impacts play an important role in deciphering Martian geologic history, whether as a mechanism to modify the lithosphere and atmosphere or as a tool to sample the planet. The various roles of impact cratering in adding a broader understanding of Mars through returned samples are examined. Five broad roles include impact craters as: (1) a process in response to a different planetary localizer environment; (2) a probe for excavating crustal/mantle materials; (3) a possible localizer of magmatic and hydrothermal processes; (4) a chronicle of changes in the volcanic, sedimentary, atmospheric, and cosmic flux history; and (5) a chronometer for extending the geologic time scale to unsampled regions. The evidence for Earth-like processes and very nonlunar styles of volcanism and tectonism may shift the emphasis of a sampling strategy away from equally fundamental issues including crustal composition, unit ages, and climate history. Impact cratering not only played an important active role in the early Martian geologic history, it also provides an important tool for addressing such issues

  8. Horizontal and vertical individualism and collectivism among college students in the United States, Taiwan, and Argentina.

    Science.gov (United States)

    Chiou, J S

    2001-10-01

    Among college students in the United States, Taiwan, and Argentina, the author examined the strength of 4 cultural patterns (horizontal collectivism, vertical collectivism, horizontal individualism, vertical individualism; H. C. Triandis, 1995). A 3-group confirmatory factor analysis established the measurement equivalence among the 3 samples before the comparison. The Taiwanese and the Argentine samples were more vertically collectivist than the U.S. sample. The U.S. and the Taiwanese samples were more vertically individualistic than the Argentine sample. The U.S. sample was more horizontally individualistic than the Argentine sample, which, in turn, was more horizontally individualistic than the Taiwanese sample.

  9. Task-Contingent Conscientiousness as a Unit of Personality at Work

    Science.gov (United States)

    Minbashian, Amirali; Wood, Robert E.; Beckmann, Nadin

    2010-01-01

    The present study examined the viability of incorporating task-contingent units into the study of personality at work, using conscientiousness as an illustrative example. We used experience-sampling data from 123 managers to show that (a) momentary conscientiousness at work is contingent on the difficulty and urgency demands of the tasks people…

  10. Role of Social Protection Unit District Cilacap

    Directory of Open Access Journals (Sweden)

    Gunawan

    2015-12-01

    Full Text Available Implementation of security and peace, order and protection of the people especially those who are within the settlement is the duty and responsibility of member units of community protection (Satlinmas, and what happens when members Satlinmas in carrying out its duties and functions not supported by the human resources of adequate quality and quantity , so the expectations and desires of the community to get security and peace, order and public protection are not met in full and result in (Satlinmas presence cannot be felt by the community. The method used in this study using qualitative research with descriptive analysis, the data obtained through documentation, observation, and interviews, sample locations were selected based on purposive sample of Cilacap, Cilacap is a district that has accommodated the institutional Linmas the organizational structure of Civil Service Police Unit and a barometer for other regions in the implementation of the enforcement of local regulations. The purpose of the study wanted to know how far Satlinmas can act in accordance with its duties and functions. Research results that Satlinmas role in organizing disaster management, the handling of security, peace and order, protection of the public at the district level are generally already be implemented, but at the neighbourhood level and harmonious citizens tasks and functions are yet to be implemented optimally.

  11. Designing an enhanced groundwater sample collection system

    International Nuclear Information System (INIS)

    Schalla, R.

    1994-10-01

    As part of an ongoing technical support mission to achieve excellence and efficiency in environmental restoration activities at the Laboratory for Energy and Health-Related Research (LEHR), Pacific Northwest Laboratory (PNL) provided guidance on the design and construction of monitoring wells and identified the most suitable type of groundwater sampling pump and accessories for monitoring wells. The goal was to utilize a monitoring well design that would allow for hydrologic testing and reduce turbidity to minimize the impact of sampling. The sampling results of the newly designed monitoring wells were clearly superior to those of the previously installed monitoring wells. The new wells exhibited reduced turbidity, in addition to improved access for instrumentation and hydrologic testing. The variable frequency submersible pump was selected as the best choice for obtaining groundwater samples. The literature references are listed at the end of this report. Despite some initial difficulties, the actual performance of the variable frequency, submersible pump and its accessories was effective in reducing sampling time and labor costs, and its ease of use was preferred over the previously used bladder pumps. The surface seals system, called the Dedicator, proved to be useful accessory to prevent surface contamination while providing easy access for water-level measurements and for connecting the pump. Cost savings resulted from the use of the pre-production pumps (beta units) donated by the manufacturer for the demonstration. However, larger savings resulted from shortened field time due to the ease in using the submersible pumps and the surface seal access system. Proper deployment of the monitoring wells also resulted in cost savings and ensured representative samples

  12. Reactions to Graphic Health Warnings in the United States

    Science.gov (United States)

    Nonnemaker, James M.; Choiniere, Conrad J.; Farrelly, Matthew C.; Kamyab, Kian; Davis, Kevin C.

    2015-01-01

    This study reports consumer reactions to the graphic health warnings selected by the Food and Drug Administration to be placed on cigarette packs in the United States. We recruited three sets of respondents for an experimental study from a national opt-in e-mail list sample: (i) current smokers aged 25 or older, (ii) young adult smokers aged 18-24…

  13. Sample Curation in Support of the OSIRIS-REx Asteroid Sample Return Mission

    Science.gov (United States)

    Righter, Kevin; Nakamura-Messenger, Keiko

    2017-01-01

    The OSIRIS-REx asteroid sample return mission launched to asteroid Bennu Sept. 8, 2016. The spacecraft will arrive at Bennu in late 2019, orbit and map the asteroid, and perform a touch and go (TAG) sampling maneuver in July 2020. After sample is stowed and confirmed the spacecraft will return to Earth, and the sample return capsule (SRC) will land in Utah in September 2023. Samples will be recovered from Utah [2] and then transported and stored in a new sample cleanroom at NASA Johnson Space Center in Houston [3]. The materials curated for the mission are described here. a) Materials Archive and Witness Plate Collection: The SRC and TAGSAM were built between March 2014 and Summer of 2015, and instruments (OTES,OVIRS, OLA, OCAMS, REXIS) were integrated from Summer 2015 until May 2016. A total of 395 items were received for the materials archive at NASA-JSC, with archiving finishing 30 days after launch (with the final archived items being related to launch operations)[4]. The materials fall into several general categories including metals (stainless steel, aluminum, titanium alloys, brass and BeCu alloy), epoxies, paints, polymers, lubricants, non-volatile-residue samples (NVR), sapphire, and various miscellaneous materials. All through the ATLO process (from March 2015 until late August 2016) contamination knowledge witness plates (Si wafer and Al foil) were deployed in the various cleanrooms in Denver and KSC to provide an additional record of particle counts and volatiles that is archived for current and future scientific studies. These plates were deployed in roughly monthly increments with each unit containing 4 Si wafers and 4 Al foils. We archived 128 individual witness plates (64 Si wafers and 64 Al foils); one of each witness plate (Si and Al) was analyzed immediately by the science team after archiving, while the remaining 3 of each are archived indefinitely. Information about each material archived is stored in an extensive database at NASA-JSC, and key

  14. Measurements of {sup 55}Fe activity in activated steel samples with GEMPix

    Energy Technology Data Exchange (ETDEWEB)

    Curioni, A. [CERN, 1211 Geneva 23 (Switzerland); Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Dinar, N. [CERN, 1211 Geneva 23 (Switzerland); Université de Paris VII, 5 rue Thomas-Mann, 75013 Paris (France); La Torre, F.P. [CERN, 1211 Geneva 23 (Switzerland); Leidner, J., E-mail: johannes.leidner@cern.ch [CERN, 1211 Geneva 23 (Switzerland); RWTH Aachen, Templergraben 55, 52056 Aachen (Germany); Murtas, F. [CERN, 1211 Geneva 23 (Switzerland); INFN-LNF, Via E. Fermi 40, 00044 Frascati (Italy); Puddu, S.; Silari, M. [CERN, 1211 Geneva 23 (Switzerland)

    2017-03-21

    In this paper we present a novel method, based on the recently developed GEMPix detector, to measure the {sup 55}Fe content in samples of metallic material activated during operation of CERN accelerators and experimental facilities. The GEMPix, a gas detector with highly pixelated read-out, has been obtained by coupling a triple Gas Electron Multiplier (GEM) to a quad Timepix ASIC. Sample preparation, measurements performed on 45 samples and data analysis are described. The calibration factor (counts per second per unit specific activity) has been obtained via measurements of the {sup 55}Fe activity determined by radiochemical analysis of the same samples. Detection limit and sensitivity to the current Swiss exemption limit are calculated. Comparison with radiochemical analysis shows inconsistency for the sensitivity for only two samples, most likely due to underestimated uncertainties of the GEMPix analysis. An operative test phase of this technique is already planned at CERN.

  15. Archaeological investigations at a toolstone source area and temporary camp: Sample Unit 19-25, Nevada Test Site, Nye County, Nevada. Technical report No. 77

    Energy Technology Data Exchange (ETDEWEB)

    Jones, R.C.; DuBarton, A.; Edwards, S.; Pippin, L.C.; Beck, C.M.

    1993-12-31

    Archaeological investigations were initiated at Sample Unit 19--25 to retrieve information concerning settlement and subsistence data on the aboriginal hunter and gatherers in the area. Studies included collection and mapping of 35.4 acres at site 26NY1408 and excavation and mapping of 0.02 acres at site 26NY7847. Cultural resources include two rock and brush structures and associated caches and a large lithic toolstone source area and lithic artifact scatter. Temporally diagnostic artifacts indicate periodic use throughout the last 12,000 years; however dates associated with projectile points indicate most use was in the Middle and Late Archaic. Radiocarbon dates from the rock and brush structures at site 26NY7847 indicate a construction date of A.D. 1640 and repair between A.D. 1800 and 1950 for feature 1 and between A.D. 1330 and 1390 and repair at A.D. 1410 for feature 2. The dates associated with feature 2 place its construction significantly earlier than similar structures found elsewhere on Pahute Mesa. Activity areas appear to reflect temporary use of the area for procurement of available lithic and faunal resources and the manufacture of tools.

  16. Sequential sampling and biorational chemistries for management of lepidopteran pests of vegetable amaranth in the Caribbean.

    Science.gov (United States)

    Clarke-Harris, Dionne; Fleischer, Shelby J

    2003-06-01

    Although vegetable amaranth, Amaranthus viridis L. and A. dubius Mart. ex Thell., production and economic importance is increasing in diversified peri-urban farms in Jamaica, lepidopteran herbivory is common even during weekly pyrethroid applications. We developed and validated a sampling plan, and investigated insecticides with new modes of action, for a complex of five species (Pyralidae: Spoladea recurvalis (F.), Herpetogramma bipunctalis (F.), Noctuidae: Spodoptera exigua (Hubner), S. frugiperda (J. E. Smith), and S. eridania Stoll). Significant within-plant variation occurred with H. bipunctalis, and a six-leaf sample unit including leaves from the inner and outer whorl was selected to sample all species. Larval counts best fit a negative binomial distribution. We developed a sequential sampling plan using a threshold of one larva per sample unit and the fitted distribution with a k(c) of 0.645. When compared with a fixed plan of 25 plants, sequential sampling recommended the same management decision on 87.5%, additional samples on 9.4%, and gave inaccurate recommendations on 3.1% of 32 farms, while reducing sample size by 46%. Insecticide frequency was reduced 33-60% when management decisions were based on sampled data compared with grower-standards, with no effect on crop damage. Damage remained high or variable (10-46%) with pyrethroid applications. Lepidopteran control was dramatically improved with ecdysone agonists (tebufenozide) or microbial metabolites (spinosyns and emamectin benzoate). This work facilitates resistance management efforts concurrent with the introduction of newer modes of action for lepidopteran control in leafy vegetable production in the Caribbean.

  17. Multivariate survivorship analysis using two cross-sectional samples.

    Science.gov (United States)

    Hill, M E

    1999-11-01

    As an alternative to survival analysis with longitudinal data, I introduce a method that can be applied when one observes the same cohort in two cross-sectional samples collected at different points in time. The method allows for the estimation of log-probability survivorship models that estimate the influence of multiple time-invariant factors on survival over a time interval separating two samples. This approach can be used whenever the survival process can be adequately conceptualized as an irreversible single-decrement process (e.g., mortality, the transition to first marriage among a cohort of never-married individuals). Using data from the Integrated Public Use Microdata Series (Ruggles and Sobek 1997), I illustrate the multivariate method through an investigation of the effects of race, parity, and educational attainment on the survival of older women in the United States.

  18. Biobank Report: United Kingdom.

    Science.gov (United States)

    Kaye, Jane; Bell, Jessica; Briceno, Linda; Mitchell, Colin

    2016-03-01

    The United Kingdom is a leader in genomics research, and the presence of numerous types of biobanks and the linking of health data and research within the UK evidences the importance of biobank-based research in the UK. There is no biobank-specific law in the UK and research on biobank materials is governed by a confusing set of statutory law, common law, regulations, and guidance documents. Several layers of applicable law, from European to local, further complicate an understanding of privacy protections. Finally, biobanks frequently contain data in addition to the samples; the legal framework in the UK generally differentiates between data and samples and the form of the data affects the applicability of legal provisions. Biobanks must be licensed by the Human Tissue Authority; certain projects must be reviewed by Research Ethics Committees, and all projects are encouraged to be reviewed by them. Data Access Committees in biobanks are also common in the UK. While this confusing array of legal provisions leaves privacy protections in biobanking somewhat unclear, changes at the EU level may contribute to harmonization of approaches to privacy. © 2016 American Society of Law, Medicine & Ethics.

  19. Pattern of alcohol use by users of a family health unit

    Directory of Open Access Journals (Sweden)

    Renata Gomes Sanches Verardino

    2014-08-01

    Full Text Available Background: Within the context of drugs, alcoholism is one of the major problems in public health. Objective: To identify the pattern of consumption of alcoholic beverages by users of a Family Health Unit in São Paulo state during reception. Method: Exploratory cross-sectionalstudy of quantitative methodology with the use of Alcohol Use Disorder Identification Test (AUDIT in 100 adult users of a Primary Health Care network. Descriptive statistical analysis was carried out. Results: Of the total sample, (74% were women, (85% made use of alcoholic beverages at low risk, and (19% were young adults; binge drinking was reported by a minority of the interviewees. The Catholics in the sample (42% reported never using alcohol excessively, followed by the Evangelicals with 22%. Conclusions: Health professionals need to have knowledge of the alcohol consumption pattern of the residents from the territory of their unit, so that they can develop prevention and health promotion programs.

  20. Electronic gaming machines and gambling disorder: a cross-cultural comparison between Brazil and the United States

    Science.gov (United States)

    Medeiros, Gustavo Costa; Leppink, Eric W.; Yaemi, Ana; Mariani, Mirella; Tavares, Hermano; Grant, Jon E.

    2015-01-01

    Aims The objective of this paper is to perform a cross-cultural comparison of gambling disorder (GD) due to electronic gaming machines (EGM), a form of gambling that may have a high addictive potential. Our goal is to investigate two treatment-seeking samples of adults collected in Brazil and the United States, countries with different socio-cultural backgrounds. This comparison may lead to a better understanding of cultural influences on GD. Methods The total studied sample involved 733 treatment-seeking subjects: 353 men and 380 women (average age = 45.80, standard deviation ±10.9). The Brazilian sample had 517 individuals and the American sample 216. Subjects were recruited by analogous strategies. Results We found that the Brazilian sample was younger, predominantly male, less likely to be Caucasian, more likely to be partnered, had a faster progression from recreational gambling to GD, and were more likely to endorse chasing losses. Conclusion This study demonstrated that there are significant differences between treatment-seeking samples of adults presenting GD due to EGM in Brazil and in the United States. These findings suggest that cultural aspects may have a relevant role in GD due to EGM. PMID:26474662

  1. Assessment of emerging contaminants including organophosphate esters and pyrethroids during DISCOVER-AQ in Houston, Texas, United States.

    Science.gov (United States)

    Usenko, Sascha; Clark, Addie; Sheesley, Rebecca

    2015-04-01

    DISCOVER-AQ (Deriving Information on Surface conditions from Column and Vertically Resolved Observations Relevant to Air Quality) is a NASA-funded air quality research program that focused on Houston, Texas, United States in September 2013. In conjunction with DISCOVER-AQ, particulate matter was collected for the month of September from four ground-based sampling sites across the Houston metropolitan area. The Houston metropolitan area is one of the most populous cities in the United States. Sampling sites included an upwind and downwind site as well as an urban (i.e. downtown) and industrial/port areas (i.e. Houston Ship Channel). Particulate matter samples were collected to examine both spatial and temporal trends (including day versus night). Particulate matter was collected on quartz fiber filters, which were analyzed for emerging classes of concern including organophosphate esters (OPEs; including flame retardants) and pyrethroids. OPEs have in recent years increased in both use and production as they replaced polybrominated diphenyl ethers flame retardants. Permethrin is one of the most commonly used mosquito adulticides in the United States.

  2. From SED HI concept to Pleiades FM detection unit measurements

    Science.gov (United States)

    Renard, Christophe; Dantes, Didier; Neveu, Claude; Lamard, Jean-Luc; Oudinot, Matthieu; Materne, Alex

    2017-11-01

    The first flight model PLEIADES high resolution instrument under Thales Alenia Space development, on behalf of CNES, is currently in integration and test phases. Based on the SED HI detection unit concept, PLEIADES detection unit has been fully qualified before the integration at telescope level. The main radiometric performances have been measured on engineering and first flight models. This paper presents the results of performances obtained on the both models. After a recall of the SED HI concept, the design and performances of the main elements (charge coupled detectors, focal plane and video processing unit), detection unit radiometric performances are presented and compared to the instrument specifications for the panchromatic and multispectral bands. The performances treated are the following: - video signal characteristics, - dark signal level and dark signal non uniformity, - photo-response non uniformity, - non linearity and differential non linearity, - temporal and spatial noises regarding system definitions PLEIADES detection unit allows tuning of different functions: reference and sampling time positioning, anti-blooming level, gain value, TDI line number. These parameters are presented with their associated criteria of optimisation to achieve system radiometric performances and their sensitivities on radiometric performances. All the results of the measurements performed by Thales Alenia Space on the PLEIADES detection units demonstrate the high potential of the SED HI concept for Earth high resolution observation system allowing optimised performances at instrument and satellite levels.

  3. Cross-Cultural Validity of the Ruminative Responses Scale in Argentina and the United States.

    Science.gov (United States)

    Arana, Fernán G; Rice, Kenneth G

    2017-09-01

    Although frequently used in the United States, the Ruminative Response Scale (RRS) has not been extensively studied in cross-cultural samples. The present study evaluated the factor structure of Treynor et al.'s 10-item version of the RRS in samples from Argentina ( N = 308) and the United States ( N = 371). In addition to testing measurement invariance between the countries, we evaluated whether the maladaptive implications of rumination were weaker for the Argentinians than for the U.S. group. Self-critical perfectionism was the criterion in those tests. Partial scalar invariance supported an 8-item version of the RRS. There were no differences in factor means or factor correlations in RRS dimensions between countries. Brooding and Reflection were positively correlated with self-critical perfectionism in both countries, with no significant differences in the sizes of these relations between the two samples. Results are discussed in terms of psychometric and cross-cultural implications for rumination.

  4. Entropic sampling of simple polymer models within Wang-Landau algorithm

    International Nuclear Information System (INIS)

    Vorontsov-Velyaminov, P N; Volkov, N A; Yurchenko, A A

    2004-01-01

    In this paper we apply a new simulation technique proposed in Wang and Landau (WL) (2001 Phys. Rev. Lett. 86 2050) to sampling of three-dimensional lattice and continuous models of polymer chains. Distributions obtained by homogeneous (unconditional) random walks are compared with results of entropic sampling (ES) within the WL algorithm. While homogeneous sampling gives reliable results typically in the range of 4-5 orders of magnitude, the WL entropic sampling yields them in the range of 20-30 orders and even larger with comparable computer effort. A combination of homogeneous and WL sampling provides reliable data for events with probabilities down to 10 -35 . For the lattice model we consider both the athermal case (self-avoiding walks, SAWs) and the thermal case when an energy is attributed to each contact between nonbonded monomers in a self-avoiding walk. For short chains the simulation results are checked by comparison with the exact data. In WL calculations for chain lengths up to N = 300 scaling relations for SAWs are well reproduced. In the thermal case distribution over the number of contacts is obtained in the N-range up to N = 100 and the canonical averages - internal energy, heat capacity, excess canonical entropy, mean square end-to-end distance - are calculated as a result in a wide temperature range. The continuous model is studied in the athermal case. By sorting conformations of a continuous phantom freely joined N-bonded chain with a unit bond length over a stochastic variable, the minimum distance between nonbonded beads, we determine the probability distribution for the N-bonded chain with hard sphere monomer units over its diameter a in the complete diameter range, 0 ≤ a ≤ 2, within a single ES run. This distribution provides us with excess specific entropy for a set of diameters a in this range. Calculations were made for chain lengths up to N = 100 and results were extrapolated to N → ∞ for a in the range 0 ≤ a ≤ 1.25

  5. Dynamics of acoustically levitated disk samples.

    Science.gov (United States)

    Xie, W J; Wei, B

    2004-10-01

    The acoustic levitation force on disk samples and the dynamics of large water drops in a planar standing wave are studied by solving the acoustic scattering problem through incorporating the boundary element method. The dependence of levitation force amplitude on the equivalent radius R of disks deviates seriously from the R3 law predicted by King's theory, and a larger force can be obtained for thin disks. When the disk aspect ratio gamma is larger than a critical value gamma(*) ( approximately 1.9 ) and the disk radius a is smaller than the critical value a(*) (gamma) , the levitation force per unit volume of the sample will increase with the enlargement of the disk. The acoustic levitation force on thin-disk samples ( gammaacoustic field for stable levitation of a large water drop is to adjust the reflector-emitter interval H slightly above the resonant interval H(n) . The simulation shows that the drop is flattened and the central parts of its top and bottom surface become concave with the increase of sound pressure level, which agrees with the experimental observation. The main frequencies of the shape oscillation under different sound pressures are slightly larger than the Rayleigh frequency because of the large shape deformation. The simulated translational frequencies of the vertical vibration under normal gravity condition agree with the theoretical analysis.

  6. Simulation of motor unit recruitment and microvascular unit perfusion: spatial considerations.

    Science.gov (United States)

    Fuglevand, A J; Segal, S S

    1997-10-01

    Muscle fiber activity is the principal stimulus for increasing capillary perfusion during exercise. The control elements of perfusion, i.e., microvascular units (MVUs), supply clusters of muscle fibers, whereas the control elements of contraction, i.e., motor units, are composed of fibers widely scattered throughout muscle. The purpose of this study was to examine how the discordant spatial domains of MVUs and motor units could influence the proportion of open capillaries (designated as perfusion) throughout a muscle cross section. A computer model simulated the locations of perfused MVUs in response to the activation of up to 100 motor units in a muscle with 40,000 fibers and a cross-sectional area of 100 mm2. The simulation increased contraction intensity by progressive recruitment of motor units. For each step of motor unit recruitment, the percentage of active fibers and the number of perfused MVUs were determined for several conditions: 1) motor unit fibers widely dispersed and motor unit territories randomly located (which approximates healthy human muscle), 2) regionalized motor unit territories, 3) reversed recruitment order of motor units, 4) densely clustered motor unit fibers, and 5) increased size but decreased number of motor units. The simulations indicated that the widespread dispersion of motor unit fibers facilitates complete capillary (MVU) perfusion of muscle at low levels of activity. The efficacy by which muscle fiber activity induced perfusion was reduced 7- to 14-fold under conditions that decreased the dispersion of active fibers, increased the size of motor units, or reversed the sequence of motor unit recruitment. Such conditions are similar to those that arise in neuromuscular disorders, with aging, or during electrical stimulation of muscle, respectively.

  7. Automatic sampling technology in wide belt conveyor with big volume of coal flow

    Energy Technology Data Exchange (ETDEWEB)

    Liu, J. [China Coal Research Institute, Beijing (China)

    2008-06-15

    The principle and technique of sampling in a wide belt conveyor with high coal flow was studied. The design method of the technology, the key parameters, the collection efficiency, the mechanical unit, power supply and control system and worksite facility were ascertained. 3 refs., 5 figs.

  8. DEVELOPMENT AND EVALUATION OF INSTRUCTIONAL UNITS FOR TEACHING PROFIT-MAXIMIZING PRINCIPLES IN VOCATIONAL AGRICULTURE. FINAL REPORT.

    Science.gov (United States)

    BARKER, RICHARD L.

    THE WRITING, EVALUATION, AND REVISION OF THE INSTRUCTIONAL UNITS WERE COMPLETED ON SCHEDULE AND A SUMMARY OF THE STUDY WILL BE PUBLISHED IN THE LOCAL "RESEARCH SERIES IN AGRICULTURAL EDUCATION" TO BE SENT TO ALL STATES. THE DEVELOPMENT AND FINDINGS OF THE STUDY WILL BE INCLUDED IN "AGRICULTURAL EDUCATION MAGAZINE." SAMPLE COPIES OF THE UNIT WERE…

  9. Advanced sampling techniques for hand-held FT-IR instrumentation

    Science.gov (United States)

    Arnó, Josep; Frunzi, Michael; Weber, Chris; Levy, Dustin

    2013-05-01

    FT-IR spectroscopy is the technology of choice to identify solid and liquid phase unknown samples. The challenging ConOps in emergency response and military field applications require a significant redesign of the stationary FT-IR bench-top instruments typically used in laboratories. Specifically, field portable units require high levels of resistance against mechanical shock and chemical attack, ease of use in restrictive gear, extreme reliability, quick and easy interpretation of results, and reduced size. In the last 20 years, FT-IR instruments have been re-engineered to fit in small suitcases for field portable use and recently further miniaturized for handheld operation. This article introduces the HazMatID™ Elite, a FT-IR instrument designed to balance the portability advantages of a handheld device with the performance challenges associated with miniaturization. In this paper, special focus will be given to the HazMatID Elite's sampling interfaces optimized to collect and interrogate different types of samples: accumulated material using the on-board ATR press, dispersed powders using the ClearSampler™ tool, and the touch-to-sample sensor for direct liquid sampling. The application of the novel sample swipe accessory (ClearSampler) to collect material from surfaces will be discussed in some detail. The accessory was tested and evaluated for the detection of explosive residues before and after detonation. Experimental results derived from these investigations will be described in an effort to outline the advantages of this technology over existing sampling methods.

  10. A longitudinal field multiple sampling ionization chamber for RIBLL2

    International Nuclear Information System (INIS)

    Tang Shuwen; Ma Peng; Lu Chengui; Duan Limin; Sun Zhiyu; Yang Herun; Zhang Jinxia; Hu Zhengguo; Xu Shanhu

    2012-01-01

    A longitudinal field MUltiple Sampling Ionization Chamber (MUSIC), which makes multiple measurements of energy loss for very high energy heavy ions at RIBLL2, has been constructed and tested with 3 constituent α source ( 239 Pu : 3.435 MeV, 241 Am : 3.913 MeV, 244 Cm : 4.356 MeV). The voltage plateau curve has been plotted and-500 V is determined as a proper work voltage. The energy resolution is 271.4 keV FWHM for the sampling unit when 3.435 MeV energy deposited. A Geant4 Monte Carlo simulation is made and it indicates the detector can provide unique particle identification for ions Z≥4. (authors)

  11. A flexible system to capture sample vials in a storage box - the box vial scanner.

    Science.gov (United States)

    Nowakowski, Steven E; Kressin, Kenneth R; Deick, Steven D

    2009-01-01

    Tracking sample vials in a research environment is a critical task and doing so efficiently can have a large impact on productivity, especially in high volume laboratories. There are several challenges to automating the capture process, including the variety of containers used to store samples. We developed a fast and robust system to capture the location of sample vials being placed in storage that allows the laboratories the flexibility to use sample containers of varying dimensions. With a single scan, this device captures the box identifier, the vial identifier and the location of each vial within a freezer storage box. The sample vials are tracked through a barcode label affixed to the cap while the boxes are tracked by a barcode label on the side of the box. Scanning units are placed at the point of use and forward data to a sever application for processing the scanned data. Scanning units consist of an industrial barcode reader mounted in a fixture positioning the box for scanning and providing lighting during the scan. The server application transforms the scan data into a list of storage locations holding vial identifiers. The list is then transferred to the laboratory database. The box vial scanner captures the IDs and location information for an entire box of sample vials into the laboratory database in a single scan. The system accommodates a wide variety of vials sizes by inserting risers under the sample box and a variety of storage box layouts are supported via the processing algorithm on the server.

  12. 76 FR 31575 - United States Standards for Grades of Frozen Onions

    Science.gov (United States)

    2011-06-01

    ... processors of frozen onions in the United States. The petition provided information on style, sample size... change in the style designations for minced style, and a correction to the text. The members agreed with the proposed section concerning requirements for Styles, Type I, Whole onions and Type II, Pearl...

  13. Variability of pesticide residues in cauliflower units collected from a field trial and market places in Greece.

    Science.gov (United States)

    Prodhan, M D H; Papadakis, Emmanouil-N; Papadopoulou-Mourkidou, Euphemia

    2016-09-01

    To estimate the variability of pesticide residue levels present in cauliflower units, a total of 142 samples were collected from a field trial of a cooperative farmer, and 120 samples were collected from different market places in Thessaloniki, Greece. The collected samples were extracted using the quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction technique, and the residues were determined by liquid chromatography-tandem mass spectrometry. The developed method was validated by evaluating the accuracy, precision, linearity, limit of detection (LOD), and limit of quantification (LOQ). The average recoveries for all the analytes, derived from the data of control samples fortified at 0.01, 0.05, 0.1, and 0.2 mg/kg, ranged from 74 to 110% with a relative standard deviation of ≤8%. The correlation coefficient (R(2)) was ≥0.997 for all the analytes using matrix-matched calibration standards. The LOD values ranged from 0.001 to 0.003 mg/kg, and the LOQ was determined at 0.01 mg/kg for all the sought analytes. The matrix effect was found to be at a considerable level, especially for cypermethrin and deltamethrin, amounting to +90% and +145%, respectively. For the field samples, the unit-to-unit variability factors (VFs) calculated for cypermethrin and deltamethrin were 2.38 and 2.32, respectively, while the average VF for the market basket samples was 5.11. In the market basket samples, residues of cypermethrin, deltamethrin, chlorpyrifos, and indoxacarb were found at levels ≥LOQ and their respective VFs were 7.12, 5.67, 5.28, and 2.40.

  14. Particle System Based Adaptive Sampling on Spherical Parameter Space to Improve the MDL Method for Construction of Statistical Shape Models

    Directory of Open Access Journals (Sweden)

    Rui Xu

    2013-01-01

    Full Text Available Minimum description length (MDL based group-wise registration was a state-of-the-art method to determine the corresponding points of 3D shapes for the construction of statistical shape models (SSMs. However, it suffered from the problem that determined corresponding points did not uniformly spread on original shapes, since corresponding points were obtained by uniformly sampling the aligned shape on the parameterized space of unit sphere. We proposed a particle-system based method to obtain adaptive sampling positions on the unit sphere to resolve this problem. Here, a set of particles was placed on the unit sphere to construct a particle system whose energy was related to the distortions of parameterized meshes. By minimizing this energy, each particle was moved on the unit sphere. When the system became steady, particles were treated as vertices to build a spherical mesh, which was then relaxed to slightly adjust vertices to obtain optimal sampling-positions. We used 47 cases of (left and right lungs and 50 cases of livers, (left and right kidneys, and spleens for evaluations. Experiments showed that the proposed method was able to resolve the problem of the original MDL method, and the proposed method performed better in the generalization and specificity tests.

  15. Accessibility of hypertensive users to health units and treatment adherence

    Directory of Open Access Journals (Sweden)

    Natasha Marques Frota

    2013-09-01

    Full Text Available We aimed to analyze the accessibility of hypertensive users to the health system with focus on treatment adherence. A cross-sectional study with quantitative approach was conducted in four Family Health Basic Units of Fortaleza-CE, Brazil. The sample consisted of 400 users. Data collection happened through a form applied from May to August 2011. About 97.5% of users were older than 40 years, and 67.2% were female. The accessibility to the referral service occurred in 47.2% of users to secondary care, of which 101 (25.2% were referred to Emergency Units, and 88 (22.0% were admitted to Inpatient Units. Most hypertensive patients adhered to healthy habits, except the use of dietetic sweeteners (36.0% and physical exercise (35.0%. The hypertensive patients had good treatment adherence and difficulty in accessibility regarding counter-referral services to secondary and tertiary care services.

  16. Regional and global atmospheric aerosol studies using the ''Gent'' stacked filter unit sampler and other aerosol collectors, with multi-elemental analysis of the samples by nuclear-related analytical techniques

    International Nuclear Information System (INIS)

    Maenhaut, W.; Francois, F.; Salma, I.; Cafmeyer, J.; Gilot, C.

    1994-01-01

    The ''Gent'' staked filter unit sampler and other collection devices are used in regional and global scale studies on the tropospheric atmospheric aerosols, its composition, sources and fate. The aerosol samples are analyzed by particle-induced X-ray emission analysis, instrumental neutron activation analysis, ion chromatography, a light reflectance technique (for determining black carbon), and gravimetry (for measuring the particular mass). In evaluating the data, use is made of receptor modelling techniques, transport models and wind sector analysis, and also of air mass trajectories and other meteorological information. Preliminary results from a long-term study in southern Norway are presented. It is suggested that the anthropogenic and soil dust aerosol components are mainly adverted to southern Norway by long-range transport and that the major fraction of the submicrometer particle mass is from anthropogenic origin. Preliminary results are also presented for an intensive study in southern Africa. On the basis of the data for two sites (about 40 km apart) in the Kruger National Park it was concluded that regionally representative aerosol samples were collected and that the biomass burning products account for more than 50% of the fine particle mass. Finally, our plans for future work are given. (author). 70 refs, 4 figs, 1 tab

  17. User violence towards nursing professionals in mental health services and emergency units

    Directory of Open Access Journals (Sweden)

    Bartolomé Llor-Esteban

    2017-01-01

    Full Text Available Workplace violence is present in many work sectors, but in the area of mental health, nurses have a higher risk due to the close relationship they have with users. This study analyzed hostile user statements against nursing professionals of Mental Health Services and Emergency Units in Health Service (MHS hospitals in Murcia, Spain, and determined the frequency of exposure to the different violent user behaviors. The study was carried out with a sample of 518 nursing professionals from four hospital services: Mental Health, Emergency Units, Medical Hospitalization, and Maternal-and-Child. The nursing staff of Mental Health and Emergency Units was the most exposed to violence. Non-physical violence was more frequent in Emergency Units, whereas physical violence was more frequent in Mental Health. Among the consequences of exposure to non-physical violence are workers’ emotional exhaustion and the presence of psychological distress.

  18. WTP Waste Feed Qualification: Glass Fabrication Unit Operation Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Stone, M. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Hanford Missions Programs; Newell, J. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Process Technology Programs; Johnson, F. C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Engineering Process Development; Edwards, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Engineering Process Development

    2016-07-14

    The waste feed qualification program is being developed to protect the Hanford Tank Waste Treatment and Immobilization Plant (WTP) design, safety basis, and technical basis by assuring waste acceptance requirements are met for each staged waste feed campaign prior to transfer from the Tank Operations Contractor to the feed receipt vessels inside the Pretreatment Facility. The Waste Feed Qualification Program Plan describes the three components of waste feed qualification: 1. Demonstrate compliance with the waste acceptance criteria 2. Determine waste processability 3. Test unit operations at laboratory scale. The glass fabrication unit operation is the final step in the process demonstration portion of the waste feed qualification process. This unit operation generally consists of combining each of the waste feed streams (high-level waste (HLW) and low-activity waste (LAW)) with Glass Forming Chemicals (GFCs), fabricating glass coupons, performing chemical composition analysis before and after glass fabrication, measuring hydrogen generation rate either before or after glass former addition, measuring rheological properties before and after glass former addition, and visual observation of the resulting glass coupons. Critical aspects of this unit operation are mixing and sampling of the waste and melter feeds to ensure representative samples are obtained as well as ensuring the fabrication process for the glass coupon is adequate. Testing was performed using a range of simulants (LAW and HLW simulants), and these simulants were mixed with high and low bounding amounts of GFCs to evaluate the mixing, sampling, and glass preparation steps in shielded cells using laboratory techniques. The tests were performed with off-the-shelf equipment at the Savannah River National Laboratory (SRNL) that is similar to equipment used in the SRNL work during qualification of waste feed for the Defense Waste Processing Facility (DWPF) and other waste treatment facilities at the

  19. Reasons that lead mothers looking for a pre-hospital unit as a first option for attendance - Sorocaba/SP

    Directory of Open Access Journals (Sweden)

    Thais Helena Campos

    2015-06-01

    Full Text Available Objective: to verify the reasons lead mothers to seek the Pre- hospital Unit of Sorocaba Western Zone (UPH-ZO as first option of attendance and quantify the inappropriate motives for this search. Method: it is an exploratory study with quantitative analyze performed at UPH-ZO through the emergence bulletin (BE and the mothers or guardians interview. Results: nine hundred mothers and guardians were interviewed. Four reasons prevailed as motivation for search the UPH-ZO by first option: better and quick resolution with technological resources provided; restrict period for attendance at the Basic Health Unit (UBS; delay for appointment in the UBS; lack of Pediatrician in this Unit. The prevalent diagnostic hypothesis in the sample was acute gastroenterocolitis and superior aerial way infections. Conclusions: for the 68.8% of the sample the looking for UPH-ZO was adequate; 31.2% referred reasons that could be solved at the UBS. This Unit must just be the entrance for the users of the Health Unique System (SUS.

  20. Correction for the absorption of plutonium alpha particles in filter paper used for dust sampling

    Energy Technology Data Exchange (ETDEWEB)

    Simons, J G

    1956-01-01

    This sample of air-borne dust collected on a filter paper when laboratory air is monitored for plutonium with the 1195 portable dust sampling unit may be regarded, for counting purposes, as a thick source with a non-uniform distribution of alpha-active plutonium. Experiments have been carried out to determine a correction factor to be applied to the observed count on the filter paper sample to correct for internal absorption in the paper and on the dust layer. From the results obtained it is recommended that a correction factor of 2 be used.

  1. Number of core samples: Mean concentrations and confidence intervals

    International Nuclear Information System (INIS)

    Jensen, L.; Cromar, R.D.; Wilmarth, S.R.; Heasler, P.G.

    1995-01-01

    This document provides estimates of how well the mean concentration of analytes are known as a function of the number of core samples, composite samples, and replicate analyses. The estimates are based upon core composite data from nine recently sampled single-shell tanks. The results can be used when determining the number of core samples needed to ''characterize'' the waste from similar single-shell tanks. A standard way of expressing uncertainty in the estimate of a mean is with a 95% confidence interval (CI). The authors investigate how the width of a 95% CI on the mean concentration decreases as the number of observations increase. Specifically, the tables and figures show how the relative half-width (RHW) of a 95% CI decreases as the number of core samples increases. The RHW of a CI is a unit-less measure of uncertainty. The general conclusions are as follows: (1) the RHW decreases dramatically as the number of core samples is increased, the decrease is much smaller when the number of composited samples or the number of replicate analyses are increase; (2) if the mean concentration of an analyte needs to be estimated with a small RHW, then a large number of core samples is required. The estimated number of core samples given in the tables and figures were determined by specifying different sizes of the RHW. Four nominal sizes were examined: 10%, 25%, 50%, and 100% of the observed mean concentration. For a majority of analytes the number of core samples required to achieve an accuracy within 10% of the mean concentration is extremely large. In many cases, however, two or three core samples is sufficient to achieve a RHW of approximately 50 to 100%. Because many of the analytes in the data have small concentrations, this level of accuracy may be satisfactory for some applications

  2. Role of intraocular Leptospira infections in the pathogenesis of Equine Recurrent Uveitis in the Southern United States

    Science.gov (United States)

    To investigate the role of intraocular leptospiral infections in horses with Equine Recurrent Uveitis (ERU) in the southern United States, blood and ocular fluid samples were collected from horses with a history and ocular findings consistent with ERU. Samples were also obtained from control horses ...

  3. Passive sampling in regulatory chemical monitoring of nonpolar organic compounds in the aquatic environment

    NARCIS (Netherlands)

    Booij, K.; Robinson, C.D.; Burgess, R.M.; Mayer, P.; Roberts, C.A.; Ahrens, L.; Allan, I.J.; Brant, J.; Jones, L.; Kraus, U.R.; Larsen, M.M.; Lepom, P.; Petersen, J.; Pröfrock, D.; Roose, P.; Schäfer, S.; Smedes, F.; Tixier, C.; Vorkamp, K.; Whitehouse, P.

    2016-01-01

    We reviewed compliance monitoring requirements in the EuropeanUnion, the United States, and the Oslo-Paris Convention for the protection of themarine environment of the North-East Atlantic, and evaluated if these are met bypassive sampling methods for nonpolar compounds. The strengths

  4. Nurse-Patient Communication Interactions in the Intensive Care Unit

    Science.gov (United States)

    Happ, Mary Beth; Garrett, Kathryn; Thomas, Dana DiVirgilio; Tate, Judith; George, Elisabeth; Houze, Martin; Radtke, Jill; Sereika, Susan

    2011-01-01

    Background The inability to speak during critical illness is a source of distress for patients, yet nurse-patient communication in the intensive care unit has not been systematically studied or measured. Objectives To describe communication interactions, methods, and assistive techniques between nurses and nonspeaking critically ill patients in the intensive care unit. Methods Descriptive observational study of the nonintervention/usual care cohort from a larger clinical trial of nurse-patient communication in a medical and a cardiothoracic surgical intensive care unit. Videorecorded interactions between 10 randomly selected nurses (5 per unit) and a convenience sample of 30 critically ill adults (15 per unit) who were awake, responsive, and unable to speak because of respiratory tract intubation were rated for frequency, success, quality, communication methods, and assistive communication techniques. Patients self-rated ease of communication. Results Nurses initiated most (86.2%) of the communication exchanges. Mean rate of completed communication exchange was 2.62 exchanges per minute. The most common positive nurse act was making eye contact with the patient. Although communication exchanges were generally (>70%) successful, more than one-third (37.7%) of communications about pain were unsuccessful. Patients rated 40% of the communication sessions with nurses as somewhat difficult to extremely difficult. Assistive communication strategies were uncommon, with little to no use of assistive communication materials (eg, writing supplies, alphabet or word boards). Conclusions Study results highlight specific areas for improvement in communication between nurses and nonspeaking patients in the intensive care unit, particularly in communication about pain and in the use of assistive communication strategies and communication materials. PMID:21362711

  5. Malaria Surveillance - United States, 2015.

    Science.gov (United States)

    Mace, Kimberly E; Arguin, Paul M; Tan, Kathrine R

    2018-05-04

    Malaria in humans is caused by intraerythrocytic protozoa of the genus Plasmodium. These parasites are transmitted by the bite of an infective female Anopheles species mosquito. The majority of malaria infections in the United States occur among persons who have traveled to regions with ongoing malaria transmission. However, malaria is occasionally acquired by persons who have not traveled out of the country through exposure to infected blood products, congenital transmission, laboratory exposure, or local mosquitoborne transmission. Malaria surveillance in the United States is conducted to provide information on its occurrence (e.g., temporal, geographic, and demographic), guide prevention and treatment recommendations for travelers and patients, and facilitate transmission control measures if locally acquired cases are identified. This report summarizes confirmed malaria cases in persons with onset of illness in 2015 and summarizes trends in previous years. Malaria cases diagnosed by blood film microscopy, polymerase chain reaction, or rapid diagnostic tests are reported to local and state health departments by health care providers or laboratory staff members. Case investigations are conducted by local and state health departments, and reports are transmitted to CDC through the National Malaria Surveillance System (NMSS), the National Notifiable Diseases Surveillance System (NNDSS), or direct CDC consultations. CDC reference laboratories provide diagnostic assistance and conduct antimalarial drug resistance marker testing on blood samples submitted by health care providers or local or state health departments. This report summarizes data from the integration of all NMSS and NNDSS cases, CDC reference laboratory reports, and CDC clinical consultations. CDC received reports of 1,517 confirmed malaria cases, including one congenital case, with an onset of symptoms in 2015 among persons who received their diagnoses in the United States. Although the number of

  6. Maternal outcomes of term breech presentation delivery: impact of successful external cephalic version in a nationwide sample of delivery admissions in the United States.

    Science.gov (United States)

    Weiniger, Carolyn F; Lyell, Deirdre J; Tsen, Lawrence C; Butwick, Alexander J; Shachar, BatZion; Callaghan, William M; Creanga, Andreea A; Bateman, Brian T

    2016-07-08

    We aimed to define the frequency and predictors of successful external cephalic version in a nationally-representative cohort of women with breech presentations and to compare maternal outcomes associated with successful external cephalic version versus persistent breech presentation. Using the Nationwide Inpatient Sample, a United States healthcare utilization database, we identified delivery admissions between 1998 and 2011 for women who had successful external cephalic version or persistent breech presentation (including unsuccessful or no external cephalic version attempt) at term. Multivariable logistic regression identified patient and hospital-level factors associated with successful external cephalic version. Maternal outcomes were compared between women who had successful external cephalic version versus persistent breech. Our study cohort comprised 1,079,576 delivery admissions with breech presentation; 56,409 (5.2 %) women underwent successful external cephalic version and 1,023,167 (94.8 %) women had persistent breech presentation at the time of delivery. The rate of cesarean delivery was lower among women who had successful external cephalic version compared to those with persistent breech (20.2 % vs. 94.9 %; p external cephalic version were also less likely to experience several measures of significant maternal morbidity including endometritis (adjusted Odds Ratio (aOR) = 0.36, 95 % Confidence Interval (CI) 0.24-0.52), sepsis (aOR = 0.35, 95 % CI 0.24-0.51) and length of stay > 7 days (aOR = 0.53, 95 % CI 0.40-0.70), but had a higher risk of chorioamnionitis (aOR = 1.83, 95 % CI 1.54-2.17). Overall a low proportion of women with breech presentation undergo successful external cephalic version, and it is associated with significant reduction in the frequency of cesarean delivery and a number of measures of maternal morbidity. Increased external cephalic version use may be an important approach to mitigate the high rate of

  7. Aerosol container-related eye injuries in the United States: 1997-2009.

    Science.gov (United States)

    Seidman, Carly J; Linakis, James G; Mello, Michael J; Greenberg, Paul B

    2011-06-01

    To quantify and characterize eye injuries related to aerosol container consumer products treated in United States hospital emergency departments (EDs) from 1997 through 2009. Retrospective study. Descriptive analysis of aerosol container-related eye injury data derived from the National Electronic Injury Surveillance System, a stratified probability sample of hospital-affiliated United States EDs. Data collected included demographic variables (gender and age), locale, diagnoses, and hospital disposition associated with aerosol container-related eye injuries treated in United States EDs from 1997 through 2009. Products associated with injury and mechanisms of injury also were extracted and analyzed. There were an estimated 10 765 (95% confidence interval [CI], 9842 to 11 688) visits to United States EDs for aerosol container-related eye injuries during the study period; 6756 (95% CI, 5771 to 7742; 63%) patients were male; 5927 (95% CI, 4956 to 6897; 55%) injuries occurred in children (age container-related eye injuries in the United States occur in men and children and that self-inflicted spray to the eye is the most common mechanism of injury. Further research is needed to devise effective prevention strategies for these types of injuries. Published by Elsevier Inc.

  8. Aquatic studies at the 100-HR-3 and 100-NR-1 operable units

    International Nuclear Information System (INIS)

    Cushing, C.E.

    1993-04-01

    Pacific Northwest Laboratory initiated a program to characterize selected aquatic biological populations to determine (1) existing levels of inorganic chemical and radionuclide contamination, and (2) the populations' suitability as indicators of chemical releases during cleanup activities at the US Department of Energy's Hanford Site. Following work plans for the ground-water operable units, lower trophic levels in the aquatic habitat (periphyton and caddisfly larvae) were evaluated for contaminants at the 100-HR-3 Operable Unit and 100-NR-1 Operable Unit. The results were evaluated to determine the need for further sampling. If the results showed no significant contamination compared to upriver levels, sampling would be discontinued. The periphyton community appears to be suitable for determining contamination levels. Baseline concentrations for stable chromium were established and will be useful for comparing samples collected when contaminant release is expected. Concentrations of 60 Co, 90 Sr, and 137 Cs in periphyton were essentially below detectable limits, which will also make this community useful in detecting potential releases of radionuclides during cleanup activities. Levels for both stable chromium and radionuclides were essentially below detection limits for caddisfly larvae. Thus, these organisms may be used to monitor suspected contaminant releases from cleanup activities; if concentrations exceed detection limits, they may be related to these activities. Two candidate threatened and endangered species of molluscs occur in the Hanford Reach of the Columbia River. These are the shortface lanx (Fisherola nuttalli), which is a Washington State candidate species, and the Columbia pebblesnail (Fluminicola columbiana), which is both a state and federal candidate species. Specimens of the shortface lanx were observed in the vicinity of N Springs (100-NR-1 Operable Unit); they likely occur throughout this area

  9. Aerosol Sampling System for Collection of Capstone Depleted Uranium Particles in a High-Energy Environment

    International Nuclear Information System (INIS)

    Holmes, Thomas D.; Guilmette, Raymond A.; Cheng, Yung-Sung; Parkhurst, MaryAnn; Hoover, Mark D.

    2009-01-01

    The Capstone Depleted Uranium Aerosol Study was undertaken to obtain aerosol samples resulting from a kinetic-energy cartridge with a large-caliber depleted uranium (DU) penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post-impact, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used to achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the vehicle commander, loader, gunner, and driver. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for depleted uranium concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol

  10. Reactions to Hill End Adolescent Unit: Interviews with 20 Ex-Patients.

    Science.gov (United States)

    Stuart-Smith, Sue

    1994-01-01

    Interviewed 20 adolescents recently discharged from Hill End Adolescent Unit. Over one-half of sample described some benefit, most notably from drama therapy, family therapy, and peer group support. Areas of difficulty included objections to video recording and one-way mirrors; dislike of being on grounds of psychiatric hospital; inadequate…

  11. Severe Visual Impairments in Infants and Toddlers in the United States

    Science.gov (United States)

    Hatton, Deborah D.; Ivy, Sarah E.; Boyer, Charles

    2013-01-01

    Introduction: This article describes the most prevalent visual conditions and other demographic characteristics of 5,931 young children with severe visual impairments in 28 states in the United States, the largest sample reported to date. The information presented in this article can assist in planning and implementing programs. Method: The data…

  12. A new chemical formulation for control of dental unit water line contamination: An 'in vitro' and clinical 'study'

    Directory of Open Access Journals (Sweden)

    Dolci Giovanni

    2002-02-01

    Full Text Available Abstract Background Water delivered by dental units during routine dental practice is highly contaminated. The aim of this study is to evaluate the efficacy of a new chemical solution flushed through Dental Unit Water Lines (DUWL for the control of contamination inside dental units. Materials and methods Six old dental units equipped with a device designed to automatically flush disinfecting solutions through the water system (Castellini Autosteril were selected. Water samples from DUWL effluents were collected in each dental unit for 10 randomly selected days, before and after a 5 minute DUWL disinfecting cycle with TetraAcetylEthileneDiamine (TAED and persalt (Ster4spray produced by Farmec spa, and distributed by Castellini spa. Water samples were plated in R2A Agar and cultured at room temperature for 7 days, and the total number of heterotrophic microorganisms counted and expressed in Log10 CFU/mL A general linear model was fitted and multiple regression ANOVA for repeated measures was used for the statistical analysis. Results The mean contamination in DUWL effluent at baseline was 5.45 ± 0.35 CFU/mL (range 4.79 to 5.93 CFU/mL. When water samples were tested "in vitro" against the chemical, no growth of heterotrophic bacteria was detected after a 5 minute contact in any of the water samples tested. After undergoing a 5 minute disinfecting cycle with the chemical, DUWL mean contamination in water effluents was 2.01 ± 0.32 CFU/mL (range 1.30 to 2.74 CFU/mL (significant difference with respect to baseline. Conclusions An inbetween patient disinfecting procedure consisting of flushing DUWL with TAED and persalt equivalent to 0.26% peracetic acid could be useful in routine dental practice for cross-contamination control.

  13. Can qualitatively similar temperature-histories be obtained in different pilot HP units?

    NARCIS (Netherlands)

    Landfeld, A.; Matser, A.M.; Strohalm, J.; Oey, I.; Plancken, van der I.; Grauwet, T.; Hendrickx, M.; Moates, G.; Furfaro, M.E.; Waldron, K.W.; Betz, M.; Halama, R.; Houska, M.

    2011-01-01

    An experimental protocol to harmonize the pressure and temperature-histories of model samples treated in different individual high pressure pilot units was developed. This protocol was based on the endpoint strategy. Step zero of this protocol consisted of an exploratory measurement of the pressure,

  14. A quantitative method to detect explosives and selected semivolatiles in soil samples by Fourier transform infrared spectroscopy

    International Nuclear Information System (INIS)

    Clapper-Gowdy, M.; Dermirgian, J.; Robitaille, G.

    1995-01-01

    This paper describes a novel Fourier transform infrared (FTIR) spectroscopic method that can be used to rapidly screen soil samples from potentially hazardous waste sites. Samples are heated in a thermal desorption unit and the resultant vapors are collected and analyzed in a long-path gas cell mounted in a FTIR. Laboratory analysis of a soil sample by FTIR takes approximately 10 minutes. This method has been developed to identify and quantify microgram concentrations of explosives in soil samples and is directly applicable to the detection of selected volatile organics, semivolatile organics, and pesticides

  15. Liquid chromatography detection unit, system, and method

    Science.gov (United States)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  16. Transuranic Storage Area (TSA)-2 container storage unit RCRA closure plan

    International Nuclear Information System (INIS)

    Lodman, D.W.; Spry, M.J.; Nolte, E.P.; Barry, G.A.

    1992-11-01

    This document describes the proposed plans for closure of the Transuranic Storage Area (TSA)-2 container storage unit at the Idaho National Engineering Laboratory in accordance with the Resource Conservation and Recovery Act closure requirements. The location, size, capacity, history, and current status of the unit are described. Future plans for the unit include incorporating the earthen-covered portion of the TSA-2 pad into a TSA retrieval enclosure along with the TSA-1 and TSAR pads, and closure of the portion of the TSA-2 pad under the Air Support Weather Shield (ASWS-2). This plan addresses closure of the ASWS-2 by decontaminating structures and equipment that may have contacted the waste. Sufficient sampling and documentation of all closure activities will be performed to demonstrate clean closure. A tentative schedule is provided in the form of a milestone chart

  17. Data Validation Package - June 2015 Groundwater and Surface Water Sampling at the Green River, Utah, Disposal Site

    Energy Technology Data Exchange (ETDEWEB)

    Linard, Joshua [USDOE Office of Legacy Management, Washington, DC (United States); Price, Jeffrey [Navarro Research and Engineering, Inc., Las Vegas, NV (United States)

    2015-08-01

    Groundwater samples were collected during the 2015 sampling event from point-of-compliance (POC) wells 0171, 0173, 0176, 0179, 0181, and 0813 to monitor the disposition of contaminants in the middle sandstone unit of the Cedar Mountain Formation. Groundwater samples also were collected from alluvium monitoring wells 0188, 0189, 0192, 0194, and 0707, and basal sandstone monitoring wells 0182, 0184, 0185, and 0588 as a best management practice. Surface locations 0846 and 0847 were sampled to monitor for degradation of water quality in the backwater area of Brown’s Wash and in the Green River immediately downstream of Brown’s Wash. The Green River location 0801 is upstream from the site and is sampled to determine background-threshold values (BTVs). Sampling and analyses were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). Water levels were measured at each sampled well. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. All six POC wells are completed in the middle sandstone unit of the Cedar Mountain Formation and are monitored to measure contaminant concentrations for comparison to proposed alternate concentration limits (ACLs), as provided in Table 1. Contaminant concentrations in the POC wells remain below their respective ACLs.

  18. Patient Safety Culture in Intensive Care Units from the Perspective of Nurses: A Cross-Sectional Study.

    Science.gov (United States)

    Farzi, Sedigheh; Moladoost, Azam; Bahrami, Masoud; Farzi, Saba; Etminani, Reza

    2017-01-01

    One of the goals of nursing is providing safe care, prevention of injury, and health promotion of patients. Patient safety in intensive care units is threatened for various reasons. This study aimed to survey patient safety culture from the perspective of nurses in intensive care units. This cross-sectional study was conducted in 2016. Sampling was done using the convenience method. The sample consisted of 367 nurses working in intensive care units of teaching hospitals affiliated to Isfahan University of Medical Sciences. Data collection was performed using a two-part questionnaire that included demographic and hospital survey on Patient Safety Culture (HSOPSC) questionnaire. Data analysis was done using descriptive statistics (mean and standard deviation). Among the 12 dimensions of safety culture, the nurses assigned the highest score to "team work within units" (97.3%) and "Organizational learning-continuous improvement" (84%). They assigned the least score to "handoffs and transitions"(21.1%), "non-punitive response to errors" (24.7%), "Staffing" (35.6%), "Communication openness" (47.5%), and "Teamwork across units" (49.4%). The patient safety culture dimensions have low levels that require adequate attention and essential measures of health care centers including facilitating teamwork, providing adequate staff, and developing a checklist of handoffs and transitions. Furthermore, to increase reporting error and to promote a patient safety culture in intensive care units, some strategies should be adopted including a system-based approach to deal with the error.

  19. Novel Sample Preparation Method for Safe and Rapid Detection of Bacillus anthracis Spores in Environmental Powders and Nasal Swabs

    OpenAIRE

    Luna, Vicki A.; King, Debra; Davis, Carisa; Rycerz, Tony; Ewert, Matthew; Cannons, Andrew; Amuso, Philip; Cattani, Jacqueline

    2003-01-01

    Bacillus anthracis spores have been used as a biological weapon in the United States. We wanted to develop a safe, rapid method of sample preparation that provided safe DNA for the detection of spores in environmental and clinical specimens. Our method reproducibly detects B. anthracis in samples containing

  20. Neutron emission from impacted solid LiD samples

    International Nuclear Information System (INIS)

    Kaushik, T.C.; Shyam, A.; Kulkarni, L.V.; Srinivasan, M.

    1993-01-01

    Nylon projectiles with 0.1 g to 0.3 g mass, accelerated to velocities of 0.2-1 km/s using a 60 cm long electromagnetic accelerator (railgun), have been impacted upon solid lithium deuteride (LiD) samples of 3 proportional counters. The output from the BF 3 set-up is monitored in several ways to characterize the possible neutron emission from the target. This includes a simple technique of counting the single channel analyser (SCA) output through a dead-time unit to identify bursts of < 100 μs duration. Counting is started after a delay of ∼ 1 ms to avoid the initial interference from the capacitor bank discharge. The signal is also recorded in a storage oscilloscope from the start of projectile acceleration along with a time marker just before the impact. From a number of shots taken with and without the samples, a significant evidence of neutron emission from the LiD samples appears to emerge. The experiments suggest that approximately 100 neutrons might be generated during every such impact in a duration of < 4 ms. (author). 7 refs., 3 figs

  1. Associations among School Characteristics and Foodservice Practices in a Nationally Representative Sample of United States Schools

    Science.gov (United States)

    Thomson, Jessica L.; Tussing-Humphreys, Lisa M.; Martin, Corby K.; LeBlanc, Monique M.; Onufrak, Stephen J.

    2012-01-01

    Objective: Determine school characteristics associated with healthy/unhealthy food service offerings or healthy food preparation practices. Design: Secondary analysis of cross-sectional data. Setting: Nationally representative sample of public and private elementary, middle, and high schools. Participants: Data from the 2006 School Health Policies…

  2. Sampling and analyses report for June 1992 semiannual postburn sampling at the RM1 UCG site, Hanna, Wyoming

    International Nuclear Information System (INIS)

    Lindblom, S.R.

    1992-08-01

    The Rocky Mountain 1 (RMl) underground coal gasification (UCG) test was conducted from November 16, 1987 through February 26, 1988 (United Engineers and Constructors 1989) at a site approximately one mile south of Hanna, Wyoming. The test consisted of dual module operation to evaluate the controlled retracting injection point (CRIP) technology, the elongated linked well (ELW) technology, and the interaction of closely spaced modules operating simultaneously. The test caused two cavities to be formed in the Hanna No. 1 coal seam and associated overburden. The Hanna No. 1 coal seam is approximately 30 ft thick and lays at depths between 350 ft and 365 ft below the surface in the test area. The coal seam is overlain by sandstones, siltstones and claystones deposited by various fluvial environments. The groundwater monitoring was designed to satisfy the requirements of the Wyoming Department of Environmental Quality (WDEQ) in addition to providing research data toward the development of UCG technology that minimizes environmental impacts. The June 1992 semiannual groundwater.sampling took place from June 10 through June 13, 1992. This event occurred nearly 34 months after the second groundwater restoration at the RM1 site and was the fifteenth sampling event since UCG operations ceased. Samples were collected for analyses of a limited suite set of parameters as listed in Table 1. With a few exceptions, the groundwater is near baseline conditions. Data from the field measurements and analysis of samples are presented. Benzene concentrations in the groundwater were below analytical detection limits

  3. Accounting for sampling patterns reverses the relative importance of trade and climate for the global sharing of exotic plants

    Science.gov (United States)

    Sofaer, Helen R.; Jarnevich, Catherine S.

    2017-01-01

    AimThe distributions of exotic species reflect patterns of human-mediated dispersal, species climatic tolerances and a suite of other biotic and abiotic factors. The relative importance of each of these factors will shape how the spread of exotic species is affected by ongoing economic globalization and climate change. However, patterns of trade may be correlated with variation in scientific sampling effort globally, potentially confounding studies that do not account for sampling patterns.LocationGlobal.Time periodMuseum records, generally from the 1800s up to 2015.Major taxa studiedPlant species exotic to the United States.MethodsWe used data from the Global Biodiversity Information Facility (GBIF) to summarize the number of plant species with exotic occurrences in the United States that also occur in each other country world-wide. We assessed the relative importance of trade and climatic similarity for explaining variation in the number of shared species while evaluating several methods to account for variation in sampling effort among countries.ResultsAccounting for variation in sampling effort reversed the relative importance of trade and climate for explaining numbers of shared species. Trade was strongly correlated with numbers of shared U.S. exotic plants between the United States and other countries before, but not after, accounting for sampling variation among countries. Conversely, accounting for sampling effort strengthened the relationship between climatic similarity and species sharing. Using the number of records as a measure of sampling effort provided a straightforward approach for the analysis of occurrence data, whereas species richness estimators and rarefaction were less effective at removing sampling bias.Main conclusionsOur work provides support for broad-scale climatic limitation on the distributions of exotic species, illustrates the need to account for variation in sampling effort in large biodiversity databases, and highlights the

  4. Frequency of candidemias in a tertiary care intensive care unit

    International Nuclear Information System (INIS)

    Yaqub, K.M.; Usman, J.; Zaidi, S.B.H.; Khalil, A.; Noor, N.; Gill, M.M.

    2013-01-01

    Objective: To determine the frequency of fungal infections in intensive care unit (ICU) of Military Hospital, Rawalpindi, a tertiary care health facility. Study Design: Cross sectional study. Place and Duration of Study: Intensive Care Department of Military Hospital Rawalpindi from 01 Jan 2012 to 30 Jun 2012. Methodology: A total of 89 patients were screened with stay of more than 5 days in intensive care unit. Thirty cases were enrolled in the study for investigation of fungal infections that had fever even after 05 days of being on broad spectrum antibiotics. Culture was done on blood, urine and catheter tip samples as per clinical condition of a patient. Results: Candida infection was found in 23.4% of study cases. The mean age of study patients was 41.2 +- 20.0 years while 63.4% were female patients as compared to 36.7% males. Conclusion: Fungal infections especially candidemias are quite frequent in the intensive care units. (author)

  5. Investigation reactor D-2201 polypropylene production unit using nuclear technique

    International Nuclear Information System (INIS)

    Wibisono; Sugiharto; Jefri Simanjuntak

    2016-01-01

    D-2201 reactor is a unit in the polypropylene production process at Pertamina Refinery Unit III Plaju. Reactor with a capacity of 45 kilo liter is not operated in normal operation condition. The validity of liquid level indicator on the unit is doubtful when refers to the production quality. Gamma source of 150 mCi Cobalt-60 and a scintillation detector had been used to scan the outer wall of the reactor to detect the liquid level during operation with a capacity of 40 %. Measurements were made along the reactor walls with 25 mm scan resolution and 5 seconds time sampling. Experiment result shows that the liquid level at the position of 40 % and at normal level position are not observed. Investigation did not find the liquid level above normal. D-2201 is diagnose not normal operating condition diagnosed with liquid abundant passed the recommended limits. Investigation advised to repair or to calibrate the liquid level indicator which is currently installed. (author)

  6. Method for Hot Real-Time Sampling of Gasification Products

    Energy Technology Data Exchange (ETDEWEB)

    Pomeroy, Marc D [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-29

    The Thermochemical Process Development Unit (TCPDU) at the National Renewable Energy Laboratory (NREL) is a highly instrumented half-ton/day pilot scale plant capable of demonstrating industrially relevant thermochemical technologies from lignocellulosic biomass conversion, including gasification. Gasification creates primarily Syngas (a mixture of Hydrogen and Carbon Monoxide) that can be utilized with synthesis catalysts to form transportation fuels and other valuable chemicals. Biomass derived gasification products are a very complex mixture of chemical components that typically contain Sulfur and Nitrogen species that can act as catalysis poisons for tar reforming and synthesis catalysts. Real-time hot online sampling techniques, such as Molecular Beam Mass Spectrometry (MBMS), and Gas Chromatographs with Sulfur and Nitrogen specific detectors can provide real-time analysis providing operational indicators for performance. Sampling typically requires coated sampling lines to minimize trace sulfur interactions with steel surfaces. Other materials used inline have also shown conversion of sulfur species into new components and must be minimized. Sample line Residence time within the sampling lines must also be kept to a minimum to reduce further reaction chemistries. Solids from ash and char contribute to plugging and must be filtered at temperature. Experience at NREL has shown several key factors to consider when designing and installing an analytical sampling system for biomass gasification products. They include minimizing sampling distance, effective filtering as close to source as possible, proper line sizing, proper line materials or coatings, even heating of all components, minimizing pressure drops, and additional filtering or traps after pressure drops.

  7. Systematic sampling with errors in sample locations

    DEFF Research Database (Denmark)

    Ziegel, Johanna; Baddeley, Adrian; Dorph-Petersen, Karl-Anton

    2010-01-01

    analysis using point process methods. We then analyze three different models for the error process, calculate exact expressions for the variances, and derive asymptotic variances. Errors in the placement of sample points can lead to substantial inflation of the variance, dampening of zitterbewegung......Systematic sampling of points in continuous space is widely used in microscopy and spatial surveys. Classical theory provides asymptotic expressions for the variance of estimators based on systematic sampling as the grid spacing decreases. However, the classical theory assumes that the sample grid...... is exactly periodic; real physical sampling procedures may introduce errors in the placement of the sample points. This paper studies the effect of errors in sample positioning on the variance of estimators in the case of one-dimensional systematic sampling. First we sketch a general approach to variance...

  8. Characterization of the Three Mile Island Unit-2 reactor building atmosphere prior to the reactor building purge

    International Nuclear Information System (INIS)

    Hartwell, J.K.; Mandler, J.W.; Duce, S.W.; Motes, B.G.

    1981-05-01

    The Three Mile Island Unit-2 reactor building atmosphere was sampled prior to the reactor building purge. Samples of the containment atmosphere were obtained using specialized sampling equipment installed through penetration R-626 at the 358-foot (109-meter) level of the TMI-2 reactor building. The samples were subsequently analyzed for radionuclide concentration and for gaseous molecular components (O 2 , N 2 , etc.) by two independent laboratories at the Idaho National Engineering Laboratory (INEL). The sampling procedures, analysis methods, and results are summarized

  9. United States National Waste Terminal Storage argillaceous rock studies

    International Nuclear Information System (INIS)

    Brunton, G.D.

    1981-01-01

    The past and present argillaceous rock studies for the US National Waste Terminal Storage Program consist of: (1) evaluation of the geological characteristics of several widespread argillaceous formations in the United States; (2) laboratory studies of the physical and chemical properties of selected argillaceous rock samples; and (3) two full-scale in situ surface heater experiments that simulate the emplacement of heat-generating radioactive waste in argillaceous rock

  10. United States National Waste Terminal Storage argillaceous rock studies

    International Nuclear Information System (INIS)

    Brunton, G.D.

    1979-01-01

    The past and present argillaceous rock studies for the US National Waste Terminal Storage Program consist of: (1) evaluation of the geological characteristics of several widespread argillaceous formations in the United States; (2) laboratory studies of the physical and chemical properties of selected argillaceous rock samples; and (3) two full-scale in-situ surface heater experiments that simulate the emplacement of heat-generating radioactive waste in argillaceous rock

  11. Efficiency comparisons of fish sampling gears for a lentic ecosystem health assessments in Korea

    Directory of Open Access Journals (Sweden)

    Jeong-Ho Han

    2016-12-01

    Full Text Available The key objective of this study was to analyze the sampling efficiency of various fish sampling gears for a lentic ecosystem health assessment. A fish survey for the lentic ecosystem health assessment model was sampled twice from 30 reservoirs during 2008–2012. During the study, fishes of 81 species comprising 53,792 individuals were sampled from 30 reservoirs. A comparison of sampling gears showed that casting nets were the best sampling gear with high species richness (69 species, whereas minnow traps were the worst gear with low richness (16 species. Fish sampling efficiency, based on the number of individual catch per unit effort, was best in fyke nets (28,028 individuals and worst in minnow traps (352 individuals. When we compared trammel nets and kick nets versus fyke nets and casting nets, the former were useful in terms of the number of fish individuals but not in terms of the number of fish species.

  12. [A comparison of convenience sampling and purposive sampling].

    Science.gov (United States)

    Suen, Lee-Jen Wu; Huang, Hui-Man; Lee, Hao-Hsien

    2014-06-01

    Convenience sampling and purposive sampling are two different sampling methods. This article first explains sampling terms such as target population, accessible population, simple random sampling, intended sample, actual sample, and statistical power analysis. These terms are then used to explain the difference between "convenience sampling" and purposive sampling." Convenience sampling is a non-probabilistic sampling technique applicable to qualitative or quantitative studies, although it is most frequently used in quantitative studies. In convenience samples, subjects more readily accessible to the researcher are more likely to be included. Thus, in quantitative studies, opportunity to participate is not equal for all qualified individuals in the target population and study results are not necessarily generalizable to this population. As in all quantitative studies, increasing the sample size increases the statistical power of the convenience sample. In contrast, purposive sampling is typically used in qualitative studies. Researchers who use this technique carefully select subjects based on study purpose with the expectation that each participant will provide unique and rich information of value to the study. As a result, members of the accessible population are not interchangeable and sample size is determined by data saturation not by statistical power analysis.

  13. The nurse work environment, job satisfaction and turnover rates in rural and urban nursing units.

    Science.gov (United States)

    Baernholdt, Marianne; Mark, Barbara A

    2009-12-01

    The aim of the present study was to determine whether there are differences in hospital characteristics, nursing unit characteristics, the nurse work environment, job satisfaction and turnover rates in rural and urban nursing units. Research in urban hospitals has found an association between the nurse work environment and job satisfaction and turnover rates, but this association has not been examined in rural hospitals. Rural and urban nursing units were compared in a national random sample of 97 United States hospitals (194 nursing units) with between 99 and 450 beds. Significant differences were found between hospital and nursing unit characteristics and the nurse work environment in rural and urban nursing units. Both nursing unit characteristics and the work environment were found to have a significant influence on nurse job satisfaction and turnover rates. Job satisfaction and turnover rates in rural and urban nursing units are associated with both nursing unit characteristics and the work environment. Both rural and urban hospitals can improve nurse job satisfaction and turnover rates by changing unit characteristics, such as creating better support services and a work environment that supports autonomous nursing practice. Rural hospitals can also improve the work environment by providing nurses with more educational opportunities.

  14. An automated blood sampling system used in positron emission tomography

    International Nuclear Information System (INIS)

    Eriksson, L.; Bohm, C.; Kesselberg, M.

    1988-01-01

    Fast dynamic function studies with positron emission tomography (PET), has the potential to give accurate information of physiological functions of the brain. This capability can be realised if the positron camera system accurately quantitates the tracer uptake in the brain with sufficiently high efficiency and in sufficiently short time intervals. However, in addition, the tracer concentration in blood, as a function of time, must be accurately determined. This paper describes and evaluates an automated blood sampling system. Two different detector units are compared. The use of the automated blood sampling system is demonstrated in studies of cerebral blood flow, in studies of the blood-brain barrier transfer of amino acids and of the cerebral oxygen consumption. 5 refs.; 7 figs

  15. Molecular epidemiology of a hepatitis C virus outbreak in a hemodialysis unit.

    Science.gov (United States)

    Bracho, Maria Alma; Gosalbes, María José; Blasco, David; Moya, Andrés; González-Candelas, Fernando

    2005-06-01

    We analyzed a hepatitis C virus (HCV) transmission case in the hemodialysis unit of a private clinic by sequencing two genome regions of virus isolates from a number of patients attending this unit and some external controls. The analysis of 337 nucleotides (nt) in the NS5B region did not provide enough resolution to ascertain which patients were actually involved in the outbreak and the potential source. Nevertheless, this region allowed the exclusion of several patients as putative sources of the transmission case based on their genotypes and phylogenetic relationships. On the other hand, the analysis of several 472-nt-long clone sequences per sample in a more rapidly evolving region of the HCV genome, coding for the envelope proteins and encompassing hypervariable region 1, allowed us to establish the existence of at least two independent transmission events involving two different source patients and three recipients. The direction of the transmissions was further corroborated by different measures of genetic variability within and among samples.

  16. Steam generator replacement in Bruce A Unit 1 and Unit 2

    International Nuclear Information System (INIS)

    Hart, R.S.

    2006-01-01

    The Bruce A Generating Station consists of four 900 MW class CANDU units. The reactor and Primary Heat Transport System for each Unit are housed within a reinforced concrete reactor vault. A large duct running below the reactor vaults accommodates the shared fuel handling system, and connects the four reactor vaults to the vacuum building. The reactor vaults, fuelling system duct and the vacuum building constitute the station vacuum containment system. Bruce A Unit 2 was shut down in 1995 and Bruce A Units 1, 3 and 4 were shutdown in 1997. Bruce A Units 3 and 4 were returned to service in late 2003 and are currently operating. Units 1 and 2 remain out of service. Bruce Power is currently undertaking a major rehabilitation of Bruce A Unit 1 and Units 2 that will extend the in-service life of these units by at least 25 years. Replacement of the Steam Generators (eight in each unit) is required; this work was awarded to SNC-Lavalin Nuclear (SLN). The existing steam drums (which house the steam separation and drying equipment) will be retained. Unit 2 is scheduled to be synchronized with the grid in 2009, followed by Unit 1 in 2009. Each Bruce A unit has two steam generating assemblies, one located above and to each end of the reactor. Each steam generating assembly consists of a horizontal cylindrical steam drum and four vertical Steam Generators. The vertical Steam Generators connect to individual nozzles that are located on the underside of the Steam Drum (SD). The steam drums are located in concrete shielding structures (steam drum enclosures). The lower sections of the Steam Generators penetrate the top of the reactor vaults: the containment pressure boundary is established by bellows assemblies that connect between the reactor vault roof slab and the Steam Generators. Each Steam Generators is supported from the bottom by a trapeze that is suspended from the reactor vault top structure. The Steam Generator Replacement (SGR) methodology developed by SLN for Unit 1

  17. High-resolution X-ray diffraction with no sample preparation.

    Science.gov (United States)

    Hansford, G M; Turner, S M R; Degryse, P; Shortland, A J

    2017-07-01

    It is shown that energy-dispersive X-ray diffraction (EDXRD) implemented in a back-reflection geometry is extremely insensitive to sample morphology and positioning even in a high-resolution configuration. This technique allows high-quality X-ray diffraction analysis of samples that have not been prepared and is therefore completely non-destructive. The experimental technique was implemented on beamline B18 at the Diamond Light Source synchrotron in Oxfordshire, UK. The majority of the experiments in this study were performed with pre-characterized geological materials in order to elucidate the characteristics of this novel technique and to develop the analysis methods. Results are presented that demonstrate phase identification, the derivation of precise unit-cell parameters and extraction of microstructural information on unprepared rock samples and other sample types. A particular highlight was the identification of a specific polytype of a muscovite in an unprepared mica schist sample, avoiding the time-consuming and difficult preparation steps normally required to make this type of identification. The technique was also demonstrated in application to a small number of fossil and archaeological samples. Back-reflection EDXRD implemented in a high-resolution configuration shows great potential in the crystallographic analysis of cultural heritage artefacts for the purposes of scientific research such as provenancing, as well as contributing to the formulation of conservation strategies. Possibilities for moving the technique from the synchrotron into museums are discussed. The avoidance of the need to extract samples from high-value and rare objects is a highly significant advantage, applicable also in other potential research areas such as palaeontology, and the study of meteorites and planetary materials brought to Earth by sample-return missions.

  18. 19 CFR 10.69 - Samples to Great Britain and Ireland under reciprocal agreement.

    Science.gov (United States)

    2010-04-01

    ... the United States and one for the use of the foreign customs authorities. The latter copy must have... 19 Customs Duties 1 2010-04-01 2010-04-01 false Samples to Great Britain and Ireland under reciprocal agreement. 10.69 Section 10.69 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF...

  19. Emotional display rules as work unit norms: a multilevel analysis of emotional labor among nurses.

    Science.gov (United States)

    Diefendorff, James M; Erickson, Rebecca J; Grandey, Alicia A; Dahling, Jason J

    2011-04-01

    Emotional labor theory has conceptualized emotional display rules as shared norms governing the expression of emotions at work. Using a sample of registered nurses working in different units of a hospital system, we provided the first empirical evidence that display rules can be represented as shared, unit-level beliefs. Additionally, controlling for the influence of dispositional affectivity, individual-level display rule perceptions, and emotion regulation, we found that unit-level display rules are associated with individual-level job satisfaction. We also showed that unit-level display rules relate to burnout indirectly through individual-level display rule perceptions and emotion regulation strategies. Finally, unit-level display rules also interacted with individual-level dispositional affectivity to predict employee use of emotion regulation strategies. We discuss how future research on emotional labor and display rules, particularly in the health care setting, can build on these findings.

  20. Case Study of Multi-Unit Risk: Multi-Unit Station Black-Out

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Kyemin; Jang, Seung-cheol [KAERI, Daejeon (Korea, Republic of); Heo, Gyunyoung [Kyung Hee University, Yongin (Korea, Republic of)

    2015-05-15

    After Fukushima Daiichi Accident, importance and public concern for Multi-Unit Risk (MUR) or Probabilistic Safety Assessment (PSA) have been increased. Most of nuclear power plant sites in the world have more than two units. These sites have been facing the problems of MUR or accident such as Fukushima. In case of South Korea, there are generally more than four units on the same site and even more than ten units are also expected. In other words, sites in South Korea also have been facing same problems. Considering number of units on the same site, potential of these problems may be larger than other countries. The purpose of this paper is to perform case study based on another paper submitted in the conference. MUR is depended on various site features such as design, shared systems/structures, layout, environmental condition, and so on. Considering various dependencies, we assessed Multi-Unit Station Black-out (MSBO) accident based on Hanul Unit 3 and 4 model. In this paper, case study for multi-unit risk or PSA had been performed. Our result was incomplete to assess total multi-unit risk because of two challenging issues. First, economic impact had not been evaluated to estimate multi-unit risk. Second, large uncertainties were included in our result because of various assumptions. These issues must be resolved in the future.

  1. Case Study of Multi-Unit Risk: Multi-Unit Station Black-Out

    International Nuclear Information System (INIS)

    Oh, Kyemin; Jang, Seung-cheol; Heo, Gyunyoung

    2015-01-01

    After Fukushima Daiichi Accident, importance and public concern for Multi-Unit Risk (MUR) or Probabilistic Safety Assessment (PSA) have been increased. Most of nuclear power plant sites in the world have more than two units. These sites have been facing the problems of MUR or accident such as Fukushima. In case of South Korea, there are generally more than four units on the same site and even more than ten units are also expected. In other words, sites in South Korea also have been facing same problems. Considering number of units on the same site, potential of these problems may be larger than other countries. The purpose of this paper is to perform case study based on another paper submitted in the conference. MUR is depended on various site features such as design, shared systems/structures, layout, environmental condition, and so on. Considering various dependencies, we assessed Multi-Unit Station Black-out (MSBO) accident based on Hanul Unit 3 and 4 model. In this paper, case study for multi-unit risk or PSA had been performed. Our result was incomplete to assess total multi-unit risk because of two challenging issues. First, economic impact had not been evaluated to estimate multi-unit risk. Second, large uncertainties were included in our result because of various assumptions. These issues must be resolved in the future

  2. 11 th fuel reload of the Unit 1, leadership with results

    International Nuclear Information System (INIS)

    Serrano, R.H.

    2006-01-01

    At the moment the companies with world class, the formation of intellectual capital is a strategy to reach the excellence; the Management of Nucleo electric Centrals (GCN), aware of this strategy to achieve the mission commended, it establishes that it is decisive the leadership among their collaborators for the achievement of the goals. The obtained results in the 11 th reload of the Unit 1 are a sample of as how the leaders and collaborators when making work in team they have achieved the best results (collective dose and reload duration), until today in what is the history of the commercial operation of the Unit 1. (Author)

  3. Groundwater-quality data in the Santa Barbara study unit, 2011: results from the California GAMA Program

    Science.gov (United States)

    Davis, Tracy A.; Kulongoski, Justin T.; Belitz, Kenneth

    2013-01-01

    Groundwater quality in the 48-square-mile Santa Barbara study unit was investigated by the U.S. Geological Survey (USGS) from January to February 2011, as part of the California State Water Resources Control Board (SWRCB) Groundwater Ambient Monitoring and Assessment (GAMA) Program’s Priority Basin Project (PBP). The GAMA-PBP was developed in response to the California Groundwater Quality Monitoring Act of 2001 and is being conducted in collaboration with the SWRCB and Lawrence Livermore National Laboratory (LLNL). The Santa Barbara study unit was the thirty-fourth study unit to be sampled as part of the GAMA-PBP. The GAMA Santa Barbara study was designed to provide a spatially unbiased assessment of untreated-groundwater quality in the primary aquifer system, and to facilitate statistically consistent comparisons of untreated-groundwater quality throughout California. The primary aquifer system is defined as those parts of the aquifers corresponding to the perforation intervals of wells listed in the California Department of Public Health (CDPH) database for the Santa Barbara study unit. Groundwater quality in the primary aquifer system may differ from the quality in the shallower or deeper water-bearing zones; shallow groundwater may be more vulnerable to surficial contamination. In the Santa Barbara study unit located in Santa Barbara and Ventura Counties, groundwater samples were collected from 24 wells. Eighteen of the wells were selected by using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells), and six wells were selected to aid in evaluation of water-quality issues (understanding wells). The groundwater samples were analyzed for organic constituents (volatile organic compounds [VOCs], pesticides and pesticide degradates, and pharmaceutical compounds); constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]); naturally occurring inorganic constituents (trace

  4. Teamwork as a nursing competence at Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Silvia Helena Henriques Camelo

    2013-03-01

    Full Text Available Objective. The aim in this study was to identify how Intensive Care Unit nurses perceive professional competences in thecare team. Methodology. Qualitative multiple case study with an exploratory focus. The sample consisted of 24 nurses from Intensive Care Units (ICU at two large hospitals. To collect the information, direct observation and - structured, non-structuredand participant - interviews were used. Results. Ninety-six percent of the participants were women, 79% were less than 40 years old, and 63% possessed less than five years of professional experience in ICU. Data analysis revealed three study categories: teamwork as a nursing management tool, improving teamwork, and interpersonal communication for teamwork. Conclusion. At the ICU where the nurses work, a teamwork strategy is observed, which demands cooperation and participation by other disciplines.

  5. The UK Biobank sample handling and storage validation studies.

    Science.gov (United States)

    Peakman, Tim C; Elliott, Paul

    2008-04-01

    and aims UK Biobank is a large prospective study in the United Kingdom to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. It involves the collection of blood and urine from 500 000 individuals aged between 40 and 69 years. How the samples are collected, processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. A series of validation studies was recommended to test the robustness of the draft sample handling and storage protocol. Samples of blood and urine were collected from 40 healthy volunteers and either processed immediately according to the protocol or maintained at specified temperatures (4 degrees C for all tubes with the exception of vacutainers containing acid citrate dextrose that were maintained at 18 degrees C) for 12, 24 or 36 h prior to processing. A further sample was maintained for 24 h at 4 degrees C, processed and the aliquots frozen at -80 degrees C for 20 days and then thawed under controlled conditions. The stability of the samples was compared for the different times in a wide variety of assays. The samples maintained at 4 degrees C were stable for at least 24 h after collection for a wide range of assays. Small but significant changes were observed in metabonomic studies in samples maintained at 4 degrees C for 36 h. There was no degradation of the samples for a range of biochemical assays after short-term freezing and thawing under controlled conditions. Whole blood maintained at 18 degrees C for 24 h in vacutainers containing acid citrate dextrose is suitable for viral immortalization techniques. The validation studies reported in this supplement provide justification for the sample handling and storage procedures adopted in the UK Biobank project.

  6. Results of initial analyses of the salt (macro) batch 11 Tank 21H qualification samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-23

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 11 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 11 composite sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amounts of solids, or unusual colors. Further sample results will be reported in a future document. This memo satisfies part of Deliverable 3 of the Technical Task Request (TTR).

  7. Evaluation of laser phosphorimetry for the analysis of uranium in biological samples from laboratory animal studies

    International Nuclear Information System (INIS)

    Gray, D.; Eidsom, A.F.

    1985-01-01

    Laser phosphorimetry has been used for uranium analyses in a variety of sample matrices, including environmental and human bioassay samples. The Scientrex-UA-3 Uranium Analyzer has been used at ITRI to acquire data on the applicability of laser phosphorimetry to analyses of uranium in the highly concentrated solutions resulting from chemical processing of biological comparisons of results with those obtained from conventional fluorometry. These comparisons have been very favorable for many sample types. Results of these comparisons and an evaluation of the data obtained with the Scintrex unit are presented

  8. Gamma ray spectrometry results from core samples collected for RESUME 95

    Energy Technology Data Exchange (ETDEWEB)

    Sanderson, D.C.W.; Allyson, J.D. [SURRC, East Kilbride, Scotland (United Kingdom); Toivonen, H.; Honkamaa, T. [STUK, Helsinki (Finland)

    1997-12-31

    Field sampling of an airfield at Vesivehmaa, near Vaeaeksy, Finland (Area I) was carried out between 26-29 May 1995, to establish the radionuclide deposition and inventory of Chernobyl derived {sup 137}Cs, and natural radionuclides. The objective was to establish a common calibration site for in-situ and airborne gamma spectrometers, for Exercise RESUME 95 conducted in August 1995. The report presents the sampling details, handling and treatment. The analyses are discussed with particular emphasis given to {sup 137}Ca, {sup 134}Cs, {sup 40}K, {sup 214}Bi and {sup 208} radionuclides, and the quantification of their respective deposition and inventories. The results have been used to estimate the effective concentrations of nuclides at the calibration site for in-situ and airborne gamma spectrometry, and the depth distribution. For {sup 137}Cs the weighted mean activity per unit area takes on values of 50.7{+-}5.2 kBq m{sup -2} at 1 m ground clearance, 51.1{+-}6.9 kBq m{sup -2} at 50 m height and 47.9{+-}8.5 kBq m{sup -2} at 100 m. The similarity of these values confirms the suitability of the Vesivehmaa site for comparison of in-situ and airborne results despite variations of a factor of two between results from individual cores. The mean {alpha}/{rho} value for {sup 137}Cs in Area I is 0.77{+-}0.10 cm{sup 2}g{sup -1} (relaxation mass per unit area, {beta} 1.31{+-}0.15 gcm{sup -2}). Additional soil sampling across parts of Area II (a 6x3 km area selected for mapping Chernobyl deposition) was carried out. The mean level of {sup 137}Cs activity from these samples was 92.4{+-}63 kBq m{sup -2}, a sample taken near Laihansuo showing the largest value obtained at 172 kBq m{sup -2}. (EG). 17 refs.

  9. Gamma ray spectrometry results from core samples collected for RESUME 95

    Energy Technology Data Exchange (ETDEWEB)

    Sanderson, D C.W.; Allyson, J D [SURRC, East Kilbride, Scotland (United Kingdom); Toivonen, H; Honkamaa, T [STUK, Helsinki (Finland)

    1998-12-31

    Field sampling of an airfield at Vesivehmaa, near Vaeaeksy, Finland (Area I) was carried out between 26-29 May 1995, to establish the radionuclide deposition and inventory of Chernobyl derived {sup 137}Cs, and natural radionuclides. The objective was to establish a common calibration site for in-situ and airborne gamma spectrometers, for Exercise RESUME 95 conducted in August 1995. The report presents the sampling details, handling and treatment. The analyses are discussed with particular emphasis given to {sup 137}Ca, {sup 134}Cs, {sup 40}K, {sup 214}Bi and {sup 208} radionuclides, and the quantification of their respective deposition and inventories. The results have been used to estimate the effective concentrations of nuclides at the calibration site for in-situ and airborne gamma spectrometry, and the depth distribution. For {sup 137}Cs the weighted mean activity per unit area takes on values of 50.7{+-}5.2 kBq m{sup -2} at 1 m ground clearance, 51.1{+-}6.9 kBq m{sup -2} at 50 m height and 47.9{+-}8.5 kBq m{sup -2} at 100 m. The similarity of these values confirms the suitability of the Vesivehmaa site for comparison of in-situ and airborne results despite variations of a factor of two between results from individual cores. The mean {alpha}/{rho} value for {sup 137}Cs in Area I is 0.77{+-}0.10 cm{sup 2}g{sup -1} (relaxation mass per unit area, {beta} 1.31{+-}0.15 gcm{sup -2}). Additional soil sampling across parts of Area II (a 6x3 km area selected for mapping Chernobyl deposition) was carried out. The mean level of {sup 137}Cs activity from these samples was 92.4{+-}63 kBq m{sup -2}, a sample taken near Laihansuo showing the largest value obtained at 172 kBq m{sup -2}. (EG). 17 refs.

  10. [Bacterial contamination of the indoor air in a transplant unit].

    Science.gov (United States)

    Matoušková, Ivanka; Holý, Ondřej

    2013-12-01

    For one year (August 2010 to July 2011), microbial contamination of the indoor air in the Transplant Unit of the Haemato-Oncology Clinic, Olomouc University Hospital was monitored monthly. Twenty sampling sites were singled out and a total of 240 indoor air samples were collected. An MAS-100 air sampler (Merck, GER) was used, air flow rate of 100 liters per minute, 1 minute. The measured values of indoor air temperature were stable. The relative air humidity ranged from 17% to 68%. The highest average value of microbial air contamination was found in the "staff entry room" (1170 CFU/m3). The lowest microbial air contamination (150-250 CFU/m3) was measured in the patient isolation units. The most frequently isolated bacterial strains were coagulase-negative staphylococci (94.3%), followed by Micrococcus spp. (67%) and Bacillus subtilis (11%). It can be assumed that the -source of these airborne bacterial strains are both patients and medical staff. They are classified as -opportunistic pathogens and as such can cause hospital infections among haemato-oncology patients.

  11. Results and analysis of saltstone cores taken from saltstone disposal unit cell 2A

    Energy Technology Data Exchange (ETDEWEB)

    Reigel, M. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hill, K. A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-03-01

    As part of an ongoing Performance Assessment (PA) Maintenance Plan, Savannah River Remediation (SRR) has developed a sampling and analyses strategy to facilitate the comparison of field-emplaced samples (i.e., saltstone placed and cured in a Saltstone Disposal Unit (SDU)) with samples prepared and cured in the laboratory. The primary objectives of the Sampling and Analyses Plan (SAP) are; (1) to demonstrate a correlation between the measured properties of laboratory-prepared, simulant samples (termed Sample Set 3), and the field-emplaced saltstone samples (termed Sample Set 9), and (2) to validate property values assumed for the Saltstone Disposal Facility (SDF) PA modeling. The analysis and property data for Sample Set 9 (i.e. six core samples extracted from SDU Cell 2A (SDU2A)) are documented in this report, and where applicable, the results are compared to the results for Sample Set 3. Relevant properties to demonstrate the aforementioned objectives include bulk density, porosity, saturated hydraulic conductivity (SHC), and radionuclide leaching behavior.

  12. Determination of exposure to respirable quartz in the stone crushing units at Azendarian-West of Iran.

    Science.gov (United States)

    Bahrami, Abdul Rahman; Golbabai, Faridah; Mahjub, Hossien; Qorbani, Farshid; Aliabadi, Mohsan; Barqi, Mohamadali

    2008-08-01

    The purpose of this study is to describe the personal exposure to respirable dust and quartz and in stone crushing units located at west of Iran. A size of 40 personal samples and 40 stationary samples were obtained and analysis was done by X-ray diffraction (XRD). The results of personal sampling were shown the concentrations of respirable dust exposure level in workers of process, hopper and drivers were 1.90, 2.22, 1.41 times greater than Occupational Safety and Health Administration permissible exposure limit (OSHA PEL). The average value of total dust and respirable dust emission from stationary sources was 9.46 mg/m(3), 1.24 mg/m(3) respectively, showing that 13.8 % of total dust is respirable. The efficiency of local exhaust ventilation (LEV) to control of particles inside of industrial units was greater than 99%. It is concluded from this research the particulate generated from stone crushing activities contain a significant amount of respirable particle. The amount of free silica in stone quartz is 85 to 97 percent that emission of particles effect to health workers. LEV has important effect in the removal of silica particles in stone crushing units. The worker of hoppers still exposed to silica more than standard limits.

  13. 1:250,000-scale Hydrologic Units of the United States

    Science.gov (United States)

    Steeves, Peter; Nebert, Douglas

    1994-01-01

    The Geographic Information Retrieval and Analysis System (GIRAS) was developed in the mid 70s to put into digital form a numberof data layers which were of interest to the USGS. One of these data layers was the Hydrologic Units. The map is based on the Hydrologic Unit Maps published by the U.S. Geological Survey Office of Water Data Coordination, together with the list descriptions and name of region, subregion, accounting units, and cataloging unit. The hydrologic units are encoded with an eight-digit number that indicates the hydrologic region (first two digits), hydrologic subregion (second two digits), accounting unit (third two digits), and cataloging unit (fourth two digits). The data produced by GIRAS was originally collected at a scale of 1:250K. Some areas, notably major cities in the west, were recompiled at a scale of 1:100K. In order to join the data together and use the data in a geographic information system (GIS) the data were processed in the ARC/INFO GUS software package. Within the GIS, the data were edgematched and the neatline boundaries between maps were removed to create a single data set for the conterminous

  14. Prevalence and Correlates of Elopement in a Nationally Representative Sample of Children with Developmental Disabilities in the United States.

    Directory of Open Access Journals (Sweden)

    Bridget Kiely

    Full Text Available Despite increased awareness and concern about children with developmental disabilities wandering away from adult supervision, there is a paucity of research about elopement. This is the first study to examine and report the prevalence and correlates of elopement in a nationally representative sample of school-age children in the United States with an autism spectrum disorder (ASD and/or cognitive impairment. Data were obtained from the CDC's "Pathways" Survey, a follow-up telephone survey of the parents of 4,032 children with a developmental condition. 3,518 children that had ASD, intellectual disability (ID, and/or developmental delay (DD at the time of survey administration were included for analysis. Children were divided into three condition groups: ASD-only; ID/DD-only; ASD+ID/DD. Logistic regression analyses were used to compare the prevalence of elopement and rates of preventive measure use (barriers and/or electronic devices across condition groups, and to examine the clinical and demographic correlates of elopement. T-tests were also performed to compare scores on the Children's Social Behavior Questionnaire (CSBQ between wanderers and non-wanderers. Overall, 26.7% of children had reportedly eloped within the previous year, most commonly from public places. Children with ASD-only and ASD+ID/DD were more likely to have eloped than those with ID/DD-only. Across all groups, wanderers scored higher than non-wanderers on five out of six CSBQ subscales; they were more likely not to realize when there is danger, to have difficulty distinguishing between strangers and familiar people, to show sudden mood changes, to over-react to everything/everyone, to get angry quickly, to get lost easily, and to panic in new situations or if change occurs. Even after controlling for elopement history, parents of children in the ASD+ID/DD group were more likely than those in the other condition groups to report using physical or electronic measures to prevent

  15. Soil sampling and analysis plan for the 3718-F Alkali Metal Treatment and Storage Facility closure activities

    Energy Technology Data Exchange (ETDEWEB)

    Sonnichsen, J.C.

    1997-05-01

    Amendment V.13.B.b to the approved closure plan (DOE-RL 1995a) requires that a soil sampling and analysis plan be prepared and submitted to the Washington State Department of Ecology (Ecology) for review and approval. Amendment V.13.B.c requires that a diagram of the 3718-F Alkali Metal Treatment and Storage Facility unit (the treatment, storage, and disposal [TSD] unit) boundary that is to be closed, including the maximum extent of operation, be prepared and submitted as part is of the soil sampling and analysis plan. This document describes the sampling and analysis that is to be performed in response to these requirements and amends the closure plan. Specifically, this document supersedes Section 6.2, lines 43--46, and Section 7.3.6 of the closure plan. Results from the analysis will be compared to cleanup levels identified in the closure plan. These cleanup levels will be established using residential exposure assumptions in accordance with the Model Toxics Control Act (MTCA) Cleanup Regulation (Washington Administrative Code [WAC] 173-340) as required in Amendment V.13.B.I. Results of all sampling, including the raw analytical data, a summary of analytical results, a data validation package, and a narrative summary with conclusions will be provided to Ecology as specified in Amendment V.13.B.e. The results and process used to collect and analyze the soil samples will be certified by a licensed professional engineer. These results and a certificate of closure for the balance of the TSD unit, as outlined in Chapter 7.0 of the approved closure plan (storage shed, concrete pad, burn building, scrubber, and reaction tanks), will provide the basis for a closure determination.

  16. Soil sampling and analysis plan for the 3718-F Alkali Metal Treatment and Storage Facility closure activities

    International Nuclear Information System (INIS)

    Sonnichsen, J.C.

    1997-01-01

    Amendment V.13.B.b to the approved closure plan (DOE-RL 1995a) requires that a soil sampling and analysis plan be prepared and submitted to the Washington State Department of Ecology (Ecology) for review and approval. Amendment V.13.B.c requires that a diagram of the 3718-F Alkali Metal Treatment and Storage Facility unit (the treatment, storage, and disposal [TSD] unit) boundary that is to be closed, including the maximum extent of operation, be prepared and submitted as part is of the soil sampling and analysis plan. This document describes the sampling and analysis that is to be performed in response to these requirements and amends the closure plan. Specifically, this document supersedes Section 6.2, lines 43--46, and Section 7.3.6 of the closure plan. Results from the analysis will be compared to cleanup levels identified in the closure plan. These cleanup levels will be established using residential exposure assumptions in accordance with the Model Toxics Control Act (MTCA) Cleanup Regulation (Washington Administrative Code [WAC] 173-340) as required in Amendment V.13.B.I. Results of all sampling, including the raw analytical data, a summary of analytical results, a data validation package, and a narrative summary with conclusions will be provided to Ecology as specified in Amendment V.13.B.e. The results and process used to collect and analyze the soil samples will be certified by a licensed professional engineer. These results and a certificate of closure for the balance of the TSD unit, as outlined in Chapter 7.0 of the approved closure plan (storage shed, concrete pad, burn building, scrubber, and reaction tanks), will provide the basis for a closure determination

  17. Variation in the annual unsatisfactory rates of selected pathogens and indicators in ready-to-eat food sampled from the point of sale or service in Wales, United Kingdom.

    Science.gov (United States)

    Meldrum, R J; Garside, J; Mannion, P; Charles, D; Ellis, P

    2012-12-01

    The Welsh Food Microbiological Forum "shopping basket" survey is a long running, structured surveillance program examining ready-to-eat food randomly sampled from the point of sale or service in Wales, United Kingdom. The annual unsatisfactory rates for selected indicators and pathogens for 1998 through 2008 were examined. All the annual unsatisfactory rates for the selected pathogens were <0.5%, and no pattern with the annual rate was observed. There was also no discernible trend observed for the annual rates of Listeria spp. (not moncytogenes), with all rates <0.5%. However, there was a trend observed for Esherichia coli, with a decrease in rate between 1998 and 2003, rapid in the first few years, and then a gradual increase in rate up to 2008. It was concluded that there was no discernible pattern to the annual unsatisfactory rates for Listeria spp. (not monocytogenes), L. monocytogenes, Staphylococcus aureus, and Bacillus cereus, but that a definite trend had been observed for E. coli.

  18. Evaluation of biological samples for specimen banking and biomonitoring by nuclear methods

    International Nuclear Information System (INIS)

    Stone, S.F.; Zeisler, R.

    1984-01-01

    In a pilot program for environmental specimen banking, human livers and marine mussels (Mytilus edulis) were sampled, analyzed and banked. Nuclear methods played a major role in the evaluation of the samples by providing concentration data for up to 37 major, mineral, and trace elements. Instrumental neutron activation analysis was complemented by neutron-capture prompt gamma activation analysis, radiochemical separations and, for the mussels, by instrumental X-ray fluorescence analysis. A cryogenic homogenization procedure was applied for sample preparation and evaluated. Assessment of accuracy was made by analyzing Standard Reference Materials and by intercomparing the techniques. Results are reported for 66 individual human liver specimens, collected at three locations in the United States, and for batches of 65 mussels from a collection made at Narragansett Bay, RI. 19 references, 23 figures, 4 tables

  19. UMTRA project water sampling and analysis plan, Monument Valley, Arizona

    International Nuclear Information System (INIS)

    1994-04-01

    The Monument Valley Uranium Mill Tailings Remedial Action (UMTRA) Project site in Cane Valley is a former uranium mill that has undergone surface remediation in the form of tailings and contaminated materials removal. Contaminated materials from the Monument Valley (Arizona) UMTRA Project site have been transported to the Mexican Hat (Utah) UMTRA Project site for consolidation with the Mexican Hat tailings. Tailings removal was completed in February 1994. Three geologic units at the site contain water: the unconsolidated eolian and alluvial deposits (alluvial aquifer), the Shinarump Conglomerate (Shinarump Member), and the De Chelly Sandstone. Water quality analyses indicate the contaminant plume has migrated north of the site and is mainly in the alluvial aquifer. An upward hydraulic gradient in the De Chelly Sandstone provides some protection to that aquifer. This water sampling and analysis plan recommends sampling domestic wells, monitor wells, and surface water in April and September 1994. The purpose of sampling is to continue periodic monitoring for the surface program, evaluate changes to water quality for site characterization, and provide data for the baseline risk assessment. Samples taken in April will be representative of high ground water levels and samples taken in September will be representative of low ground water levels. Filtered and nonfiltered samples will be analyzed for plume indicator parameters and baseline risk assessment parameters

  20. STATISTICAL LANDMARKS AND PRACTICAL ISSUES REGARDING THE USE OF SIMPLE RANDOM SAMPLING IN MARKET RESEARCHES

    Directory of Open Access Journals (Sweden)

    CODRUŢA DURA

    2010-01-01

    Full Text Available The sample represents a particular segment of the statistical populationchosen to represent it as a whole. The representativeness of the sample determines the accuracyfor estimations made on the basis of calculating the research indicators and the inferentialstatistics. The method of random sampling is part of probabilistic methods which can be usedwithin marketing research and it is characterized by the fact that it imposes the requirementthat each unit belonging to the statistical population should have an equal chance of beingselected for the sampling process. When the simple random sampling is meant to be rigorouslyput into practice, it is recommended to use the technique of random number tables in order toconfigure the sample which will provide information that the marketer needs. The paper alsodetails the practical procedure implemented in order to create a sample for a marketingresearch by generating random numbers using the facilities offered by Microsoft Excel.