WorldWideScience

Sample records for sampling technique called

  1. Sampling phased array a new technique for signal processing and ultrasonic imaging

    OpenAIRE

    Bulavinov, A.; Joneit, D.; Kröning, M.; Bernus, L.; Dalichow, M.H.; Reddy, K.M.

    2006-01-01

    Different signal processing and image reconstruction techniques are applied in ultrasonic non-destructive material evaluation. In recent years, rapid development in the fields of microelectronics and computer engineering lead to wide application of phased array systems. A new phased array technique, called "Sampling Phased Array" has been developed in Fraunhofer Institute for non-destructive testing. It realizes unique approach of measurement and processing of ultrasonic signals. The sampling...

  2. The role of graphene-based sorbents in modern sample preparation techniques.

    Science.gov (United States)

    de Toffoli, Ana Lúcia; Maciel, Edvaldo Vasconcelos Soares; Fumes, Bruno Henrique; Lanças, Fernando Mauro

    2018-01-01

    The application of graphene-based sorbents in sample preparation techniques has increased significantly since 2011. These materials have good physicochemical properties to be used as sorbent and have shown excellent results in different sample preparation techniques. Graphene and its precursor graphene oxide have been considered to be good candidates to improve the extraction and concentration of different classes of target compounds (e.g., parabens, polycyclic aromatic hydrocarbon, pyrethroids, triazines, and so on) present in complex matrices. Its applications have been employed during the analysis of different matrices (e.g., environmental, biological and food). In this review, we highlight the most important characteristics of graphene-based material, their properties, synthesis routes, and the most important applications in both off-line and on-line sample preparation techniques. The discussion of the off-line approaches includes methods derived from conventional solid-phase extraction focusing on the miniaturized magnetic and dispersive modes. The modes of microextraction techniques called stir bar sorptive extraction, solid phase microextraction, and microextraction by packed sorbent are discussed. The on-line approaches focus on the use of graphene-based material mainly in on-line solid phase extraction, its variation called in-tube solid-phase microextraction, and on-line microdialysis systems. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Accurate recapture identification for genetic mark–recapture studies with error-tolerant likelihood-based match calling and sample clustering

    Science.gov (United States)

    Sethi, Suresh; Linden, Daniel; Wenburg, John; Lewis, Cara; Lemons, Patrick R.; Fuller, Angela K.; Hare, Matthew P.

    2016-01-01

    Error-tolerant likelihood-based match calling presents a promising technique to accurately identify recapture events in genetic mark–recapture studies by combining probabilities of latent genotypes and probabilities of observed genotypes, which may contain genotyping errors. Combined with clustering algorithms to group samples into sets of recaptures based upon pairwise match calls, these tools can be used to reconstruct accurate capture histories for mark–recapture modelling. Here, we assess the performance of a recently introduced error-tolerant likelihood-based match-calling model and sample clustering algorithm for genetic mark–recapture studies. We assessed both biallelic (i.e. single nucleotide polymorphisms; SNP) and multiallelic (i.e. microsatellite; MSAT) markers using a combination of simulation analyses and case study data on Pacific walrus (Odobenus rosmarus divergens) and fishers (Pekania pennanti). A novel two-stage clustering approach is demonstrated for genetic mark–recapture applications. First, repeat captures within a sampling occasion are identified. Subsequently, recaptures across sampling occasions are identified. The likelihood-based matching protocol performed well in simulation trials, demonstrating utility for use in a wide range of genetic mark–recapture studies. Moderately sized SNP (64+) and MSAT (10–15) panels produced accurate match calls for recaptures and accurate non-match calls for samples from closely related individuals in the face of low to moderate genotyping error. Furthermore, matching performance remained stable or increased as the number of genetic markers increased, genotyping error notwithstanding.

  4. Pairing call-response surveys and distance sampling for a mammalian carnivore

    Science.gov (United States)

    Hansen, Sara J. K.; Frair, Jacqueline L.; Underwood, Harold B.; Gibbs, James P.

    2015-01-01

    Density estimates accounting for differential animal detectability are difficult to acquire for wide-ranging and elusive species such as mammalian carnivores. Pairing distance sampling with call-response surveys may provide an efficient means of tracking changes in populations of coyotes (Canis latrans), a species of particular interest in the eastern United States. Blind field trials in rural New York State indicated 119-m linear error for triangulated coyote calls, and a 1.8-km distance threshold for call detectability, which was sufficient to estimate a detection function with precision using distance sampling. We conducted statewide road-based surveys with sampling locations spaced ≥6 km apart from June to August 2010. Each detected call (be it a single or group) counted as a single object, representing 1 territorial pair, because of uncertainty in the number of vocalizing animals. From 524 survey points and 75 detections, we estimated the probability of detecting a calling coyote to be 0.17 ± 0.02 SE, yielding a detection-corrected index of 0.75 pairs/10 km2 (95% CI: 0.52–1.1, 18.5% CV) for a minimum of 8,133 pairs across rural New York State. Importantly, we consider this an index rather than true estimate of abundance given the unknown probability of coyote availability for detection during our surveys. Even so, pairing distance sampling with call-response surveys provided a novel, efficient, and noninvasive means of monitoring populations of wide-ranging and elusive, albeit reliably vocal, mammalian carnivores. Our approach offers an effective new means of tracking species like coyotes, one that is readily extendable to other species and geographic extents, provided key assumptions of distance sampling are met.

  5. Sample size estimation and sampling techniques for selecting a representative sample

    Directory of Open Access Journals (Sweden)

    Aamir Omair

    2014-01-01

    Full Text Available Introduction: The purpose of this article is to provide a general understanding of the concepts of sampling as applied to health-related research. Sample Size Estimation: It is important to select a representative sample in quantitative research in order to be able to generalize the results to the target population. The sample should be of the required sample size and must be selected using an appropriate probability sampling technique. There are many hidden biases which can adversely affect the outcome of the study. Important factors to consider for estimating the sample size include the size of the study population, confidence level, expected proportion of the outcome variable (for categorical variables/standard deviation of the outcome variable (for numerical variables, and the required precision (margin of accuracy from the study. The more the precision required, the greater is the required sample size. Sampling Techniques: The probability sampling techniques applied for health related research include simple random sampling, systematic random sampling, stratified random sampling, cluster sampling, and multistage sampling. These are more recommended than the nonprobability sampling techniques, because the results of the study can be generalized to the target population.

  6. Sampling phased array - a new technique for ultrasonic signal processing and imaging

    OpenAIRE

    Verkooijen, J.; Boulavinov, A.

    2008-01-01

    Over the past 10 years, the improvement in the field of microelectronics and computer engineering has led to significant advances in ultrasonic signal processing and image construction techniques that are currently being applied to non-destructive material evaluation. A new phased array technique, called 'Sampling Phased Array', has been developed in the Fraunhofer Institute for Non-Destructive Testing([1]). It realises a unique approach of measurement and processing of ultrasonic signals. Th...

  7. Information systems performance evaluation, introducing a two-level technique: Case study call centers

    Directory of Open Access Journals (Sweden)

    Hesham A. Baraka

    2015-03-01

    The objective of this paper was to introduce a new technique that can support decision makers in the call centers industry to evaluate, and analyze the performance of call centers. The technique presented is derived from the research done on measuring the success or failure of information systems. Two models are mainly adopted namely: the Delone and Mclean model first introduced in 1992 and the Design Reality Gap model introduced by Heeks in 2002. Two indices are defined to calculate the performance of the call center; the success index and the Gap Index. An evaluation tool has been developed to allow call centers managers to evaluate the performance of their call centers in a systematic analytical approach; the tool was applied on 4 call centers from different areas, simple applications such as food ordering, marketing, and sales, technical support systems, to more real time services such as the example of emergency control systems. Results showed the importance of using information systems models to evaluate complex systems as call centers. The models used allow identifying the dimensions for the call centers that are facing challenges, together with an identification of the individual indicators in these dimensions that are causing the poor performance of the call center.

  8. Two sampling techniques for game meat

    OpenAIRE

    van der Merwe, Maretha; Jooste, Piet J.; Hoffman, Louw C.; Calitz, Frikkie J.

    2013-01-01

    A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g) and square centimetres (cm2) for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12) that statistically proved the two measuring units correlated. The two sampling...

  9. Two sampling techniques for game meat

    Directory of Open Access Journals (Sweden)

    Maretha van der Merwe

    2013-03-01

    Full Text Available A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g and square centimetres (cm2 for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12 that statistically proved the two measuring units correlated. The two sampling techniques were conducted on the same game carcasses (n = 13 and analyses performed for aerobic plate count (APC, Escherichia coli and Staphylococcus aureus, for both techniques. A more representative result was obtained by swabbing and no damage was caused to the carcass. Conversely, the excision technique yielded fewer organisms and caused minor damage to the carcass. The recovery ratio from the sampling technique improved 5.4 times for APC, 108.0 times for E. coli and 3.4 times for S. aureus over the results obtained from the excision technique. It was concluded that the sampling methods of excision and swabbing can be used to obtain bacterial profiles from both export and local carcasses and could be used to indicate whether game carcasses intended for the local market are possibly on par with game carcasses intended for the export market and therefore safe for human consumption.

  10. Two sampling techniques for game meat.

    Science.gov (United States)

    van der Merwe, Maretha; Jooste, Piet J; Hoffman, Louw C; Calitz, Frikkie J

    2013-03-20

    A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g) and square centimetres (cm2) for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12) that statistically proved the two measuring units correlated. The two sampling techniques were conducted on the same game carcasses (n = 13) and analyses performed for aerobic plate count (APC), Escherichia coli and Staphylococcus aureus, for both techniques. A more representative result was obtained by swabbing and no damage was caused to the carcass. Conversely, the excision technique yielded fewer organisms and caused minor damage to the carcass. The recovery ratio from the sampling technique improved 5.4 times for APC, 108.0 times for E. coli and 3.4 times for S. aureus over the results obtained from the excision technique. It was concluded that the sampling methods of excision and swabbing can be used to obtain bacterial profiles from both export and local carcasses and could be used to indicate whether game carcasses intended for the local market are possibly on par with game carcasses intended for the export market and therefore safe for human consumption.

  11. Radioisotope Sample Measurement Techniques in Medicine and Biology. Proceedings of the Symposium on Radioisotope Sample Measurement Techniques

    International Nuclear Information System (INIS)

    1965-01-01

    The medical and biological applications of radioisotopes depend on two basically different types of measurements, those on living subjects in vivo and those on samples in vitro. The International Atomic Energy Agency has in the past held several meetings on in vivo measurement techniques, notably whole-body counting and radioisotope scanning. The present volume contains the Proceedings of the first Symposium the Agency has organized to discuss the various aspects of techniques for sample measurement in vitro. The range of these sample measurement techniques is very wide. The sample may weigh a few milligrams or several hundred grams, and may be in the gaseous, liquid or solid state. Its radioactive content may consist of a single, known radioisotope or several unknown ones. The concentration of radioactivity may be low, medium or high. The measurements may be made manually or automatically and any one of the many radiation detectors now available may be used. The 53 papers presented at the Symposium illustrate the great variety of methods now in use for radioactive- sample measurements. The first topic discussed is gamma-ray spectrometry, which finds an increasing number of applications in sample measurements. Other sections of the Proceedings deal with: the use of computers in gamma-ray spectrometry and multiple tracer techniques; recent developments in activation analysis where both gamma-ray spectrometry and computing techniques are applied; thin-layer and paper radio chromatographic techniques for use with low energy beta-ray emitters; various aspects of liquid scintillation counting techniques in the measurement of alpha- and beta-ray emitters, including chemical and colour quenching; autoradiographic techniques; calibration of equipment; and standardization of radioisotopes. Finally, some applications of solid-state detectors are presented; this section may be regarded as a preview of important future developments. The meeting was attended by 203 participants

  12. Sampling phased array, a new technique for ultrasonic signal processing and imaging now available to industry

    OpenAIRE

    Verkooijen, J.; Bulavinov, A.

    2008-01-01

    Over the past 10 years the improvement in the field of microelectronics and computer engineering has led to significant advances in ultrasonic signal processing and image construction techniques that are currently being applied to non-destructive material evaluation. A new phased array technique, called "Sampling Phased Array" has been developed in the Fraunhofer Institute for non-destructive testing [1]. It realizes a unique approach of measurement and processing of ultrasonic signals. The s...

  13. Experimental technique to measure thoron generation rate of building material samples using RAD7 detector

    International Nuclear Information System (INIS)

    Csige, I.; Szabó, Zs.; Szabó, Cs.

    2013-01-01

    Thoron ( 220 Rn) is the second most abundant radon isotope in our living environment. In some dwellings it is present in significant amount which calls for its identification and remediation. Indoor thoron originates mainly from building materials. In this work we have developed and tested an experimental technique to measure thoron generation rate in building material samples using RAD7 radon-thoron detector. The mathematical model of the measurement technique provides the thoron concentration response of RAD7 as a function of the sample thickness. For experimental validation of the technique an adobe building material sample was selected for measuring the thoron concentration at nineteen different sample thicknesses. Fitting the parameters of the model to the measurement results, both the generation rate and the diffusion length of thoron was estimated. We have also determined the optimal sample thickness for estimating the thoron generation rate from a single measurement. -- Highlights: • RAD7 is used for the determination of thoron generation rate (emanation). • The described model takes into account the thoron decay and attenuation. • The model describes well the experimental results. • A single point measurement method is offered at a determined sample thickness

  14. Critical evaluation of sample pretreatment techniques.

    Science.gov (United States)

    Hyötyläinen, Tuulia

    2009-06-01

    Sample preparation before chromatographic separation is the most time-consuming and error-prone part of the analytical procedure. Therefore, selecting and optimizing an appropriate sample preparation scheme is a key factor in the final success of the analysis, and the judicious choice of an appropriate procedure greatly influences the reliability and accuracy of a given analysis. The main objective of this review is to critically evaluate the applicability, disadvantages, and advantages of various sample preparation techniques. Particular emphasis is placed on extraction techniques suitable for both liquid and solid samples.

  15. Newly introduced sample preparation techniques: towards miniaturization.

    Science.gov (United States)

    Costa, Rosaria

    2014-01-01

    Sampling and sample preparation are of crucial importance in an analytical procedure, representing quite often a source of errors. The technique chosen for the isolation of analytes greatly affects the success of a chemical determination. On the other hand, growing concerns about environmental and human safety, along with the introduction of international regulations for quality control, have moved the interest of scientists towards specific needs. Newly introduced sample preparation techniques are challenged to meet new criteria: (i) miniaturization, (ii) higher sensitivity and selectivity, and (iii) automation. In this survey, the most recent techniques introduced in the field of sample preparation will be described and discussed, along with many examples of applications.

  16. Comparison of sampling techniques for use in SYVAC

    International Nuclear Information System (INIS)

    Dalrymple, G.J.

    1984-01-01

    The Stephen Howe review (reference TR-STH-1) recommended the use of a deterministic generator (DG) sampling technique for sampling the input values to the SYVAC (SYstems Variability Analysis Code) program. This technique was compared with Monte Carlo simple random sampling (MC) by taking a 1000 run case of SYVAC using MC as the reference case. The results show that DG appears relatively inaccurate for most values of consequence when used with 11 sample intervals. If 22 sample intervals are used then DG generates cumulative distribution functions that are statistically similar to the reference distribution. 400 runs of DG or MC are adequate to generate a representative cumulative distribution function. The MC technique appears to perform better than DG for the same number of runs. However, the DG predicts higher doses and in view of the importance of generating data in the high dose region this sampling technique with 22 sample intervals is recommended for use in SYVAC. (author)

  17. Arsenic, Antimony, Chromium, and Thallium Speciation in Water and Sediment Samples with the LC-ICP-MS Technique

    Directory of Open Access Journals (Sweden)

    Magdalena Jabłońska-Czapla

    2015-01-01

    Full Text Available Chemical speciation is a very important subject in the environmental protection, toxicology, and chemical analytics due to the fact that toxicity, availability, and reactivity of trace elements depend on the chemical forms in which these elements occur. Research on low analyte levels, particularly in complex matrix samples, requires more and more advanced and sophisticated analytical methods and techniques. The latest trends in this field concern the so-called hyphenated techniques. Arsenic, antimony, chromium, and (underestimated thallium attract the closest attention of toxicologists and analysts. The properties of those elements depend on the oxidation state in which they occur. The aim of the following paper is to answer the question why the speciation analytics is so important. The paper also provides numerous examples of the hyphenated technique usage (e.g., the LC-ICP-MS application in the speciation analysis of chromium, antimony, arsenic, or thallium in water and bottom sediment samples. An important issue addressed is the preparation of environmental samples for speciation analysis.

  18. Proteomic Challenges: Sample Preparation Techniques for Microgram-Quantity Protein Analysis from Biological Samples

    Directory of Open Access Journals (Sweden)

    Peter Feist

    2015-02-01

    Full Text Available Proteins regulate many cellular functions and analyzing the presence and abundance of proteins in biological samples are central focuses in proteomics. The discovery and validation of biomarkers, pathways, and drug targets for various diseases can be accomplished using mass spectrometry-based proteomics. However, with mass-limited samples like tumor biopsies, it can be challenging to obtain sufficient amounts of proteins to generate high-quality mass spectrometric data. Techniques developed for macroscale quantities recover sufficient amounts of protein from milligram quantities of starting material, but sample losses become crippling with these techniques when only microgram amounts of material are available. To combat this challenge, proteomicists have developed micro-scale techniques that are compatible with decreased sample size (100 μg or lower and still enable excellent proteome coverage. Extraction, contaminant removal, protein quantitation, and sample handling techniques for the microgram protein range are reviewed here, with an emphasis on liquid chromatography and bottom-up mass spectrometry-compatible techniques. Also, a range of biological specimens, including mammalian tissues and model cell culture systems, are discussed.

  19. Proteomic Challenges: Sample Preparation Techniques for Microgram-Quantity Protein Analysis from Biological Samples

    Science.gov (United States)

    Feist, Peter; Hummon, Amanda B.

    2015-01-01

    Proteins regulate many cellular functions and analyzing the presence and abundance of proteins in biological samples are central focuses in proteomics. The discovery and validation of biomarkers, pathways, and drug targets for various diseases can be accomplished using mass spectrometry-based proteomics. However, with mass-limited samples like tumor biopsies, it can be challenging to obtain sufficient amounts of proteins to generate high-quality mass spectrometric data. Techniques developed for macroscale quantities recover sufficient amounts of protein from milligram quantities of starting material, but sample losses become crippling with these techniques when only microgram amounts of material are available. To combat this challenge, proteomicists have developed micro-scale techniques that are compatible with decreased sample size (100 μg or lower) and still enable excellent proteome coverage. Extraction, contaminant removal, protein quantitation, and sample handling techniques for the microgram protein range are reviewed here, with an emphasis on liquid chromatography and bottom-up mass spectrometry-compatible techniques. Also, a range of biological specimens, including mammalian tissues and model cell culture systems, are discussed. PMID:25664860

  20. Proteomic challenges: sample preparation techniques for microgram-quantity protein analysis from biological samples.

    Science.gov (United States)

    Feist, Peter; Hummon, Amanda B

    2015-02-05

    Proteins regulate many cellular functions and analyzing the presence and abundance of proteins in biological samples are central focuses in proteomics. The discovery and validation of biomarkers, pathways, and drug targets for various diseases can be accomplished using mass spectrometry-based proteomics. However, with mass-limited samples like tumor biopsies, it can be challenging to obtain sufficient amounts of proteins to generate high-quality mass spectrometric data. Techniques developed for macroscale quantities recover sufficient amounts of protein from milligram quantities of starting material, but sample losses become crippling with these techniques when only microgram amounts of material are available. To combat this challenge, proteomicists have developed micro-scale techniques that are compatible with decreased sample size (100 μg or lower) and still enable excellent proteome coverage. Extraction, contaminant removal, protein quantitation, and sample handling techniques for the microgram protein range are reviewed here, with an emphasis on liquid chromatography and bottom-up mass spectrometry-compatible techniques. Also, a range of biological specimens, including mammalian tissues and model cell culture systems, are discussed.

  1. NAIL SAMPLING TECHNIQUE AND ITS INTERPRETATION

    Directory of Open Access Journals (Sweden)

    TZAR MN

    2011-01-01

    Full Text Available The clinical suspicion of onychomyosis based on appearance of the nails, requires culture for confirmation. This is because treatment requires prolonged use of systemic agents which may cause side effects. One of the common problems encountered is improper nail sampling technique which results in loss of essential information. The unfamiliar terminologies used in reporting culture results may intimidate physicians resulting in misinterpretation and hamper treatment decision. This article provides a simple guide on nail sampling technique and the interpretation of culture results.

  2. Development of sampling techniques for ITER Type B radwaste

    International Nuclear Information System (INIS)

    Hong, Kwon Pyo; Kim, Sung Geun; Jung, Sang Hee; Oh, Wan Ho; Park, Myung Chul; Kim, Hee Moon; Ahn, Sang Bok

    2016-01-01

    There are several difficulties and limitation in sampling activities. As the Type B radwaste components are mostly metallic(mostly stainless steel) and bulk(∼ 1 m in size and ∼ 100 mm in thickness), it is difficult in taking samples from the surface of Type B radwaste by remote operation. But also, sampling should be performed without use of any liquid coolant to avoid the spread of contamination. And all sampling procedures are carried in the hot cell red zone with remote operation. Three kinds of sampling techniques are being developed. They are core sampling, chip sampling, and wedge sampling, which are the candidates of sampling techniques to be applied to ITER hot cell. Object materials for sampling are stainless steel or Cu alloy block in order to simulate ITER Type B radwaste. The best sampling technique for ITER Type B radwaste among the three sampling techniques will be suggested in several months after finishing the related experiment

  3. Development of sampling techniques for ITER Type B radwaste

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Kwon Pyo; Kim, Sung Geun; Jung, Sang Hee; Oh, Wan Ho; Park, Myung Chul; Kim, Hee Moon; Ahn, Sang Bok [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    There are several difficulties and limitation in sampling activities. As the Type B radwaste components are mostly metallic(mostly stainless steel) and bulk(∼ 1 m in size and ∼ 100 mm in thickness), it is difficult in taking samples from the surface of Type B radwaste by remote operation. But also, sampling should be performed without use of any liquid coolant to avoid the spread of contamination. And all sampling procedures are carried in the hot cell red zone with remote operation. Three kinds of sampling techniques are being developed. They are core sampling, chip sampling, and wedge sampling, which are the candidates of sampling techniques to be applied to ITER hot cell. Object materials for sampling are stainless steel or Cu alloy block in order to simulate ITER Type B radwaste. The best sampling technique for ITER Type B radwaste among the three sampling techniques will be suggested in several months after finishing the related experiment.

  4. Boat sampling technique for assessment of ageing of components

    International Nuclear Information System (INIS)

    Kumar, Kundan; Shyam, T.V.; Kayal, J.N.; Rupani, B.B.

    2006-01-01

    Boat sampling technique (BST) is a surface sampling technique, which has been developed for obtaining, in-situ, metal samples from the surface of an operating component without affecting its operating service life. The BST is non-destructive in nature and the sample is obtained without plastic deformation or without thermal degradation of the parent material. The shape and size of the sample depends upon the shape of the cutter and the surface geometry of the parent material. Miniature test specimens are generated from the sample and the specimens are subjected to various tests, viz. Metallurgical Evaluation, Metallographic Evaluation, Micro-hardness Evaluation, sensitisation test, small punch test etc. to confirm the integrity and assessment of safe operating life of the component. This paper highlights design objective of boat sampling technique, description of sampling module, sampling cutter and its performance evaluation, cutting process, boat samples, operational sequence of sampling module, qualification of sampling module, qualification of sampling technique, qualification of scooped region of the parent material, sample retrieval system, inspection, testing and examination to be carried out on the boat samples and scooped region. (author)

  5. Urine sampling techniques in symptomatic primary-care patients

    DEFF Research Database (Denmark)

    Holm, Anne; Aabenhus, Rune

    2016-01-01

    in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. Conclusions: At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However......Background: Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection...... a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. Results: We included...

  6. Non-terminal blood sampling techniques in guinea pigs.

    Science.gov (United States)

    Birck, Malene M; Tveden-Nyborg, Pernille; Lindblad, Maiken M; Lykkesfeldt, Jens

    2014-10-11

    Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical features of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e.g., the saphenous and jugular veins, each technique containing both advantages and disadvantages(4,5). Here, we present four different blood sampling techniques for either conscious or anaesthetized guinea pigs. The procedures are all non-terminal procedures provided that sample volumes and number of samples do not exceed guidelines for blood collection in laboratory animals(6). All the described methods have been thoroughly tested and applied for repeated in vivo blood sampling in studies within our research facility.

  7. Differences in sampling techniques on total post-mortem tryptase.

    Science.gov (United States)

    Tse, R; Garland, J; Kesha, K; Elstub, H; Cala, A D; Ahn, Y; Stables, S; Palmiere, C

    2017-11-20

    The measurement of mast cell tryptase is commonly used to support the diagnosis of anaphylaxis. In the post-mortem setting, the literature recommends sampling from peripheral blood sources (femoral blood) but does not specify the exact sampling technique. Sampling techniques vary between pathologists, and it is unclear whether different sampling techniques have any impact on post-mortem tryptase levels. The aim of this study is to compare the difference in femoral total post-mortem tryptase levels between two sampling techniques. A 6-month retrospective study comparing femoral total post-mortem tryptase levels between (1) aspirating femoral vessels with a needle and syringe prior to evisceration and (2) femoral vein cut down during evisceration. Twenty cases were identified, with three cases excluded from analysis. There was a statistically significant difference (paired t test, p sampling methods. The clinical significance of this finding and what factors may contribute to it are unclear. When requesting post-mortem tryptase, the pathologist should consider documenting the exact blood collection site and method used for collection. In addition, blood samples acquired by different techniques should not be mixed together and should be analyzed separately if possible.

  8. Microextraction sample preparation techniques in biomedical analysis.

    Science.gov (United States)

    Szultka, Malgorzata; Pomastowski, Pawel; Railean-Plugaru, Viorica; Buszewski, Boguslaw

    2014-11-01

    Biologically active compounds are found in biological samples at relatively low concentration levels. The sample preparation of target compounds from biological, pharmaceutical, environmental, and food matrices is one of the most time-consuming steps in the analytical procedure. The microextraction techniques are dominant. Metabolomic studies also require application of proper analytical technique for the determination of endogenic metabolites present in biological matrix on trace concentration levels. Due to the reproducibility of data, precision, relatively low cost of the appropriate analysis, simplicity of the determination, and the possibility of direct combination of those techniques with other methods (combination types on-line and off-line), they have become the most widespread in routine determinations. Additionally, sample pretreatment procedures have to be more selective, cheap, quick, and environmentally friendly. This review summarizes the current achievements and applications of microextraction techniques. The main aim is to deal with the utilization of different types of sorbents for microextraction and emphasize the use of new synthesized sorbents as well as to bring together studies concerning the systematic approach to method development. This review is dedicated to the description of microextraction techniques and their application in biomedical analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Convergence and Efficiency of Adaptive Importance Sampling Techniques with Partial Biasing

    Science.gov (United States)

    Fort, G.; Jourdain, B.; Lelièvre, T.; Stoltz, G.

    2018-04-01

    We propose a new Monte Carlo method to efficiently sample a multimodal distribution (known up to a normalization constant). We consider a generalization of the discrete-time Self Healing Umbrella Sampling method, which can also be seen as a generalization of well-tempered metadynamics. The dynamics is based on an adaptive importance technique. The importance function relies on the weights (namely the relative probabilities) of disjoint sets which form a partition of the space. These weights are unknown but are learnt on the fly yielding an adaptive algorithm. In the context of computational statistical physics, the logarithm of these weights is, up to an additive constant, the free-energy, and the discrete valued function defining the partition is called the collective variable. The algorithm falls into the general class of Wang-Landau type methods, and is a generalization of the original Self Healing Umbrella Sampling method in two ways: (i) the updating strategy leads to a larger penalization strength of already visited sets in order to escape more quickly from metastable states, and (ii) the target distribution is biased using only a fraction of the free-energy, in order to increase the effective sample size and reduce the variance of importance sampling estimators. We prove the convergence of the algorithm and analyze numerically its efficiency on a toy example.

  10. Design and building of a homemade sample changer for automation of the irradiation in neutron activation analysis technique

    International Nuclear Information System (INIS)

    Gago, Javier; Hernandez, Yuri; Baltuano, Oscar; Bedregal, Patricia; Lopez, Yon; Urquizo, Rafael

    2014-01-01

    Because the RP-10 research reactor operates during weekends, it was necessary to design and build a sample changer for irradiation as part of the automation process of neutron activation analysis technique. The device is formed by an aluminum turntable disk which can accommodate 19 polyethylene capsules, containing samples to be sent using the pneumatic transfer system from the laboratory to the irradiation position. The system is operate by a control switchboard to send and return capsules in a variable preset time and by two different ways, allowing the determination of short, medium and long lived radionuclides. Also another mechanism is designed called 'exchange valve' for changing travel paths (pipelines) allowing the irradiated samples to be stored for a longer time in the reactor hall. The system design has allowed complete automation of this technique, enabling the irradiation of samples without the presence of an analyst. The design, construction and operation of the device is described and presented in this article. (authors).

  11. New materials for sample preparation techniques in bioanalysis.

    Science.gov (United States)

    Nazario, Carlos Eduardo Domingues; Fumes, Bruno Henrique; da Silva, Meire Ribeiro; Lanças, Fernando Mauro

    2017-02-01

    The analysis of biological samples is a complex and difficult task owing to two basic and complementary issues: the high complexity of most biological matrices and the need to determine minute quantities of active substances and contaminants in such complex sample. To succeed in this endeavor samples are usually subject to three steps of a comprehensive analytical methodological approach: sample preparation, analytes isolation (usually utilizing a chromatographic technique) and qualitative/quantitative analysis (usually with the aid of mass spectrometric tools). Owing to the complex nature of bio-samples, and the very low concentration of the target analytes to be determined, selective sample preparation techniques is mandatory in order to overcome the difficulties imposed by these two constraints. During the last decade new chemical synthesis approaches has been developed and optimized, such as sol-gel and molecularly imprinting technologies, allowing the preparation of novel materials for sample preparation including graphene and derivatives, magnetic materials, ionic liquids, molecularly imprinted polymers, and much more. In this contribution we will review these novel techniques and materials, as well as their application to the bioanalysis niche. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. The persistent sampling bias in developmental psychology: A call to action.

    Science.gov (United States)

    Nielsen, Mark; Haun, Daniel; Kärtner, Joscha; Legare, Cristine H

    2017-10-01

    Psychology must confront the bias in its broad literature toward the study of participants developing in environments unrepresentative of the vast majority of the world's population. Here, we focus on the implications of addressing this challenge, highlight the need to address overreliance on a narrow participant pool, and emphasize the value and necessity of conducting research with diverse populations. We show that high-impact-factor developmental journals are heavily skewed toward publishing articles with data from WEIRD (Western, educated, industrialized, rich, and democratic) populations. Most critically, despite calls for change and supposed widespread awareness of this problem, there is a habitual dependence on convenience sampling and little evidence that the discipline is making any meaningful movement toward drawing from diverse samples. Failure to confront the possibility that culturally specific findings are being misattributed as universal traits has broad implications for the construction of scientifically defensible theories and for the reliable public dissemination of study findings. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. A comparative study of sampling techniques for monitoring carcass contamination

    NARCIS (Netherlands)

    Snijders, J.M.A.; Janssen, M.H.W.; Gerats, G.E.; Corstiaensen, G.P.

    1984-01-01

    Four bacteriological sampling techniques i.e. the excision, double swab, agar contract and modified agar contact techniques were compared by sampling pig carcasses before and after chilling. As well as assessing the advantages and disadvantages of the techniques particular attention was paid to

  14. Sample preparation for special PIE-techniques at ITU

    International Nuclear Information System (INIS)

    Toscano, E.H.; Manzel, R.

    2002-01-01

    Several sample preparation techniques were developed and installed in hot cells. The techniques were conceived to evaluate the performance of highly burnt fuel rods and include: (a) a device for the removal of the fuel, (b) a method for the preparation of the specimen ends for the welding of new end caps and for the careful cleaning of samples for Transmission Electron Microscopy and Glow Discharge Mass Spectroscopy, (c) a sample pressurisation device for long term creep tests, and (d) a diameter measuring device for creep or burst samples. Examples of the determination of the mechanical properties, the behaviour under transient conditions and for the assessment of the corrosion behaviour of high burnup cladding materials are presented. (author)

  15. New trends in sample preparation techniques for environmental analysis.

    Science.gov (United States)

    Ribeiro, Cláudia; Ribeiro, Ana Rita; Maia, Alexandra S; Gonçalves, Virgínia M F; Tiritan, Maria Elizabeth

    2014-01-01

    Environmental samples include a wide variety of complex matrices, with low concentrations of analytes and presence of several interferences. Sample preparation is a critical step and the main source of uncertainties in the analysis of environmental samples, and it is usually laborious, high cost, time consuming, and polluting. In this context, there is increasing interest in developing faster, cost-effective, and environmentally friendly sample preparation techniques. Recently, new methods have been developed and optimized in order to miniaturize extraction steps, to reduce solvent consumption or become solventless, and to automate systems. This review attempts to present an overview of the fundamentals, procedure, and application of the most recently developed sample preparation techniques for the extraction, cleanup, and concentration of organic pollutants from environmental samples. These techniques include: solid phase microextraction, on-line solid phase extraction, microextraction by packed sorbent, dispersive liquid-liquid microextraction, and QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe).

  16. Non-terminal blood sampling techniques in Guinea pigs

    DEFF Research Database (Denmark)

    Birck, Malene Muusfeldt; Tveden-Nyborg, Pernille; Lindblad, Maiken Marie

    2014-01-01

    Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical features...... of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require...... repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e...

  17. LVQ-SMOTE - Learning Vector Quantization based Synthetic Minority Over-sampling Technique for biomedical data.

    Science.gov (United States)

    Nakamura, Munehiro; Kajiwara, Yusuke; Otsuka, Atsushi; Kimura, Haruhiko

    2013-10-02

    Over-sampling methods based on Synthetic Minority Over-sampling Technique (SMOTE) have been proposed for classification problems of imbalanced biomedical data. However, the existing over-sampling methods achieve slightly better or sometimes worse result than the simplest SMOTE. In order to improve the effectiveness of SMOTE, this paper presents a novel over-sampling method using codebooks obtained by the learning vector quantization. In general, even when an existing SMOTE applied to a biomedical dataset, its empty feature space is still so huge that most classification algorithms would not perform well on estimating borderlines between classes. To tackle this problem, our over-sampling method generates synthetic samples which occupy more feature space than the other SMOTE algorithms. Briefly saying, our over-sampling method enables to generate useful synthetic samples by referring to actual samples taken from real-world datasets. Experiments on eight real-world imbalanced datasets demonstrate that our proposed over-sampling method performs better than the simplest SMOTE on four of five standard classification algorithms. Moreover, it is seen that the performance of our method increases if the latest SMOTE called MWMOTE is used in our algorithm. Experiments on datasets for β-turn types prediction show some important patterns that have not been seen in previous analyses. The proposed over-sampling method generates useful synthetic samples for the classification of imbalanced biomedical data. Besides, the proposed over-sampling method is basically compatible with basic classification algorithms and the existing over-sampling methods.

  18. Application of digital sampling techniques to particle identification

    International Nuclear Information System (INIS)

    Bardelli, L.; Poggi, G.; Bini, M.; Carraresi, L.; Pasquali, G.; Taccetti, N.

    2003-01-01

    An application of digital sampling techniques is presented which can greatly simplify experiments involving sub-nanosecond time-mark determinations and energy measurements with nuclear detectors, used for Pulse Shape Analysis and Time of Flight measurements in heavy ion experiments. In this work a 100 M Sample/s, 12 bit analog to digital converter has been used: examples of this technique applied to Silicon and CsI(Tl) detectors in heavy-ions experiments involving particle identification via Pulse Shape analysis and Time of Flight measurements are presented. The system is suited for applications to large detector arrays and to different kinds of detectors. Some preliminary results regarding the simulation of current signals in Silicon detectors are also discussed. (authors)

  19. Sampling techniques for thrips (Thysanoptera: Thripidae) in preflowering tomato.

    Science.gov (United States)

    Joost, P Houston; Riley, David G

    2004-08-01

    Sampling techniques for thrips (Thysanoptera: Thripidae) were compared in preflowering tomato plants at the Coastal Plain Experiment Station in Tifton, GA, in 2000 and 2003, to determine the most effective method of determining abundance of thrips on tomato foliage early in the growing season. Three relative sampling techniques, including a standard insect aspirator, a 946-ml beat cup, and an insect vacuum device, were compared for accuracy to an absolute method and to themselves for precision and efficiency of sampling thrips. Thrips counts of all relative sampling methods were highly correlated (R > 0.92) to the absolute method. The aspirator method was the most accurate compared with the absolute sample according to regression analysis in 2000. In 2003, all sampling methods were considered accurate according to Dunnett's test, but thrips numbers were lower and sample variation was greater than in 2000. In 2000, the beat cup method had the lowest relative variation (RV) or best precision, at 1 and 8 d after transplant (DAT). Only the beat cup method had RV values <25 for all sampling dates. In 2003, the beat cup method had the lowest RV value at 15 and 21 DAT. The beat cup method also was the most efficient method for all sample dates in both years. Frankliniella fusca (Pergande) was the most abundant thrips species on the foliage of preflowering tomato in both years of study at this location. Overall, the best thrips sampling technique tested was the beat cup method in terms of precision and sampling efficiency.

  20. On some surprising statistical properties of a DNA fingerprinting technique called AFLP

    NARCIS (Netherlands)

    Gort, G.

    2010-01-01

    AFLP is a widely used DNA fingerprinting technique, resulting in band absence - presence profiles, like a bar code. Bands represent DNA fragments, sampled from the genome of an individual plant or other organism. The DNA fragments travel through a lane of an electrophoretic gel or microcapillary

  1. Use of nuclear technique in samples for agricultural purposes

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Kerley A. P. de; Sperling, Eduardo Von, E-mail: kerley@ufmg.br, E-mail: kerleyfisica@yahoo.com.br [Department of Sanitary and Environmental Engineering Federal University of Minas Gerais, Belo Horizonte (Brazil); Menezes, Maria Angela B. C.; Jacomino, Vanusa M.F. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-01-15

    The concern related to environment is growing. Due to this, it is needed to determine chemical elements in a large range of concentration. The neutron activation technique (NAA) determines the elemental composition by the measurement of artificial radioactivity in a sample that was submitted to a neutron flux. NAA is a sensitive and accurate technique with low detection limits. An example of application of NAA was the measurement of concentrations of rare earth elements (REE) in waste samples of phosphogypsum (PG) and cerrado soil samples (clayey and sandy soils). Additionally, a soil reference material of the International Atomic Energy Agency (IAEA) was also analyzed. The REE concentration in PG samples was two times higher than those found in national fertilizers, (total of 4,000 mg kg{sup -1}), 154 times greater than the values found in the sandy soil (26 mg kg{sup -1}) and 14 times greater than the in clayey soil (280 mg kg{sup -1}). The experimental results for the reference material were inside the uncertainty of the certified values pointing out the accuracy of the method (95%). The determination of La, Ce, Pr, Nd, Pm, Sm, Eu, Tb, Dy, Ho, Er, Tm, Yb and Lu in the samples and reference material confirmed the versatility of the technique on REE determination in soil and phosphogypsum samples that are matrices for agricultural interest. (author)

  2. Use of nuclear technique in samples for agricultural purposes

    International Nuclear Information System (INIS)

    Oliveira, Kerley A. P. de; Sperling, Eduardo Von; Menezes, Maria Angela B. C.; Jacomino, Vanusa M.F.

    2013-01-01

    The concern related to environment is growing. Due to this, it is needed to determine chemical elements in a large range of concentration. The neutron activation technique (NAA) determines the elemental composition by the measurement of artificial radioactivity in a sample that was submitted to a neutron flux. NAA is a sensitive and accurate technique with low detection limits. An example of application of NAA was the measurement of concentrations of rare earth elements (REE) in waste samples of phosphogypsum (PG) and cerrado soil samples (clayey and sandy soils). Additionally, a soil reference material of the International Atomic Energy Agency (IAEA) was also analyzed. The REE concentration in PG samples was two times higher than those found in national fertilizers, (total of 4,000 mg kg -1 ), 154 times greater than the values found in the sandy soil (26 mg kg -1 ) and 14 times greater than the in clayey soil (280 mg kg -1 ). The experimental results for the reference material were inside the uncertainty of the certified values pointing out the accuracy of the method (95%). The determination of La, Ce, Pr, Nd, Pm, Sm, Eu, Tb, Dy, Ho, Er, Tm, Yb and Lu in the samples and reference material confirmed the versatility of the technique on REE determination in soil and phosphogypsum samples that are matrices for agricultural interest. (author)

  3. Development of analytical techniques for safeguards environmental samples at JAEA

    International Nuclear Information System (INIS)

    Sakurai, Satoshi; Magara, Masaaki; Usuda, Shigekazu; Watanabe, Kazuo; Esaka, Fumitaka; Hirayama, Fumio; Lee, Chi-Gyu; Yasuda, Kenichiro; Inagawa, Jun; Suzuki, Daisuke; Iguchi, Kazunari; Kokubu, Yoko S.; Miyamoto, Yutaka; Ohzu, Akira

    2007-01-01

    JAEA has been developing, under the auspices of the Ministry of Education, Culture, Sports, Science and Technology of Japan, analytical techniques for ultra-trace amounts of nuclear materials in environmental samples in order to contribute to the strengthened safeguards system. Development of essential techniques for bulk and particle analysis, as well as screening, of the environmental swipe samples has been established as ultra-trace analytical methods of uranium and plutonium. In January 2003, JAEA was qualified, including its quality control system, as a member of the JAEA network analytical laboratories for environmental samples. Since 2004, JAEA has conducted the analysis of domestic and the IAEA samples, through which JAEA's analytical capability has been verified and improved. In parallel, advanced techniques have been developed in order to expand the applicability to the samples of various elemental composition and impurities and to improve analytical accuracy and efficiency. This paper summarizes the trace of the technical development in environmental sample analysis at JAEA, and refers to recent trends of research and development in this field. (author)

  4. Optimizing of verification photographs by using the so-called tangential field technique

    International Nuclear Information System (INIS)

    Proske, H.; Merte, H.; Kratz, H.

    1991-01-01

    When irradiating under high voltage condition, verification photographs prove to be difficult to take if the Gantry position is not aligned to 0deg respectively 180deg, since the patient is being irradiated diagonally. Under these conditions it is extremely difficult to align the X-ray-cartridge vertically to the central beam of the therapeutic radiation. This results in, amongst others, misprojections, so that definite dimensions of portrayed organ structures become practical impossible to determine. This paper describes how we have solved these problems on our high voltage units (tele-gamma cobalt unit and linear-accelerator). By using simple accessories, determination of dimensions of organ structures, as shown on the verification photographs, are made possible. We illustrate our method by using the so-called tangential fields technique when irradiating mamma carcinoma. (orig.) [de

  5. An orientation-space super sampling technique for six-dimensional diffraction contrast tomography

    NARCIS (Netherlands)

    N.R. Viganò (Nicola); K.J. Batenburg (Joost); W. Ludwig (Wolfgang)

    2016-01-01

    textabstractDiffraction contrast tomography (DCT) is an X-ray full-field imaging technique that allows for the non-destructive three-dimensional investigation of polycrystalline materials and the determination of the physical and morphological properties of their crystallographic domains, called

  6. Water sampling techniques for continuous monitoring of pesticides in water

    Directory of Open Access Journals (Sweden)

    Šunjka Dragana

    2017-01-01

    Full Text Available Good ecological and chemical status of water represents the most important aim of the Water Framework Directive 2000/60/EC, which implies respect of water quality standards at the level of entire river basin (2008/105/EC and 2013/39/EC. This especially refers to the control of pesticide residues in surface waters. In order to achieve the set goals, a continuous monitoring program that should provide a comprehensive and interrelated overview of water status should be implemented. However, it demands the use of appropriate analysis techniques. Until now, the procedure for sampling and quantification of residual pesticide quantities in aquatic environment was based on the use of traditional sampling techniques that imply periodical collecting of individual samples. However, this type of sampling provides only a snapshot of the situation in regard to the presence of pollutants in water. As an alternative, the technique of passive sampling of pollutants in water, including pesticides has been introduced. Different samplers are available for pesticide sampling in surface water, depending on compounds. The technique itself is based on keeping a device in water over a longer period of time which varies from several days to several weeks, depending on the kind of compound. In this manner, the average concentrations of pollutants dissolved in water during a time period (time-weighted average concentrations, TWA are obtained, which enables monitoring of trends in areal and seasonal variations. The use of these techniques also leads to an increase in sensitivity of analytical methods, considering that pre-concentration of analytes takes place within the sorption medium. However, the use of these techniques for determination of pesticide concentrations in real water environments requires calibration studies for the estimation of sampling rates (Rs. Rs is a volume of water per time, calculated as the product of overall mass transfer coefficient and area of

  7. Magnetic separation techniques in sample preparation for biological analysis: a review.

    Science.gov (United States)

    He, Jincan; Huang, Meiying; Wang, Dongmei; Zhang, Zhuomin; Li, Gongke

    2014-12-01

    Sample preparation is a fundamental and essential step in almost all the analytical procedures, especially for the analysis of complex samples like biological and environmental samples. In past decades, with advantages of superparamagnetic property, good biocompatibility and high binding capacity, functionalized magnetic materials have been widely applied in various processes of sample preparation for biological analysis. In this paper, the recent advancements of magnetic separation techniques based on magnetic materials in the field of sample preparation for biological analysis were reviewed. The strategy of magnetic separation techniques was summarized. The synthesis, stabilization and bio-functionalization of magnetic nanoparticles were reviewed in detail. Characterization of magnetic materials was also summarized. Moreover, the applications of magnetic separation techniques for the enrichment of protein, nucleic acid, cell, bioactive compound and immobilization of enzyme were described. Finally, the existed problems and possible trends of magnetic separation techniques for biological analysis in the future were proposed. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. The electron transport problem sampling by Monte Carlo individual collision technique

    International Nuclear Information System (INIS)

    Androsenko, P.A.; Belousov, V.I.

    2005-01-01

    The problem of electron transport is of most interest in all fields of the modern science. To solve this problem the Monte Carlo sampling has to be used. The electron transport is characterized by a large number of individual interactions. To simulate electron transport the 'condensed history' technique may be used where a large number of collisions are grouped into a single step to be sampled randomly. Another kind of Monte Carlo sampling is the individual collision technique. In comparison with condensed history technique researcher has the incontestable advantages. For example one does not need to give parameters altered by condensed history technique like upper limit for electron energy, resolution, number of sub-steps etc. Also the condensed history technique may lose some very important tracks of electrons because of its limited nature by step parameters of particle movement and due to weakness of algorithms for example energy indexing algorithm. There are no these disadvantages in the individual collision technique. This report presents some sampling algorithms of new version BRAND code where above mentioned technique is used. All information on electrons was taken from Endf-6 files. They are the important part of BRAND. These files have not been processed but directly taken from electron information source. Four kinds of interaction like the elastic interaction, the Bremsstrahlung, the atomic excitation and the atomic electro-ionization were considered. In this report some results of sampling are presented after comparison with analogs. For example the endovascular radiotherapy problem (P2) of QUADOS2002 was presented in comparison with another techniques that are usually used. (authors)

  9. Solid Phase Microextraction and Related Techniques for Drugs in Biological Samples

    OpenAIRE

    Moein, Mohammad Mahdi; Said, Rana; Bassyouni, Fatma; Abdel-Rehim, Mohamed

    2014-01-01

    In drug discovery and development, the quantification of drugs in biological samples is an important task for the determination of the physiological performance of the investigated drugs. After sampling, the next step in the analytical process is sample preparation. Because of the low concentration levels of drug in plasma and the variety of the metabolites, the selected extraction technique should be virtually exhaustive. Recent developments of sample handling techniques are directed, from o...

  10. Manipulation of biological samples using micro and nano techniques.

    Science.gov (United States)

    Castillo, Jaime; Dimaki, Maria; Svendsen, Winnie Edith

    2009-01-01

    The constant interest in handling, integrating and understanding biological systems of interest for the biomedical field, the pharmaceutical industry and the biomaterial researchers demand the use of techniques that allow the manipulation of biological samples causing minimal or no damage to their natural structure. Thanks to the advances in micro- and nanofabrication during the last decades several manipulation techniques offer us the possibility to image, characterize and manipulate biological material in a controlled way. Using these techniques the integration of biomaterials with remarkable properties with physical transducers has been possible, giving rise to new and highly sensitive biosensing devices. This article reviews the different techniques available to manipulate and integrate biological materials in a controlled manner either by sliding them along a surface (2-D manipulation), by grapping them and moving them to a new position (3-D manipulation), or by manipulating and relocating them applying external forces. The advantages and drawbacks are mentioned together with examples that reflect the state of the art of manipulation techniques for biological samples (171 references).

  11. The electron transport problem sampling by Monte Carlo individual collision technique

    Energy Technology Data Exchange (ETDEWEB)

    Androsenko, P.A.; Belousov, V.I. [Obninsk State Technical Univ. of Nuclear Power Engineering, Kaluga region (Russian Federation)

    2005-07-01

    The problem of electron transport is of most interest in all fields of the modern science. To solve this problem the Monte Carlo sampling has to be used. The electron transport is characterized by a large number of individual interactions. To simulate electron transport the 'condensed history' technique may be used where a large number of collisions are grouped into a single step to be sampled randomly. Another kind of Monte Carlo sampling is the individual collision technique. In comparison with condensed history technique researcher has the incontestable advantages. For example one does not need to give parameters altered by condensed history technique like upper limit for electron energy, resolution, number of sub-steps etc. Also the condensed history technique may lose some very important tracks of electrons because of its limited nature by step parameters of particle movement and due to weakness of algorithms for example energy indexing algorithm. There are no these disadvantages in the individual collision technique. This report presents some sampling algorithms of new version BRAND code where above mentioned technique is used. All information on electrons was taken from Endf-6 files. They are the important part of BRAND. These files have not been processed but directly taken from electron information source. Four kinds of interaction like the elastic interaction, the Bremsstrahlung, the atomic excitation and the atomic electro-ionization were considered. In this report some results of sampling are presented after comparison with analogs. For example the endovascular radiotherapy problem (P2) of QUADOS2002 was presented in comparison with another techniques that are usually used. (authors)

  12. NAIL SAMPLING TECHNIQUE AND ITS INTERPRETATION

    OpenAIRE

    TZAR MN; LEELAVATHI M

    2011-01-01

    The clinical suspicion of onychomyosis based on appearance of the nails, requires culture for confirmation. This is because treatment requires prolonged use of systemic agents which may cause side effects. One of the common problems encountered is improper nail sampling technique which results in loss of essential information. The unfamiliar terminologies used in reporting culture results may intimidate physicians resulting in misinterpretation and hamper treatment decision. This article prov...

  13. Sample preparation techniques for (p, X) spectrometry

    International Nuclear Information System (INIS)

    Whitehead, N.E.

    1985-01-01

    Samples are ashed at low temperature, using oxygen plasma; a rotary evaporator, and freeze drying speeded up the ashing. The new design of apparatus manufactured was only 10 watt but was as efficient as a 200 watt commercial machine; a circuit diagram is included. Samples of hair and biopsy samples of skin were analysed by the technique. A wool standard was prepared for interlaboratory comparison exercises. It was based on New Zealand merino sheep wool and was 2.9 kg in weight. A washing protocol was developed, which preserves most of the trace element content. The wool was ground in liquid nitrogen using a plastic pestle and beaker, driven by a rotary drill press. (author)

  14. Application of the Sampling Selection Technique in Approaching Financial Audit

    Directory of Open Access Journals (Sweden)

    Victor Munteanu

    2018-03-01

    Full Text Available In his professional approach, the financial auditor has a wide range of working techniques, including selection techniques. They are applied depending on the nature of the information available to the financial auditor, the manner in which they are presented - paper or electronic format, and, last but not least, the time available. Several techniques are applied, successively or in parallel, to increase the safety of the expressed opinion and to provide the audit report with a solid basis of information. Sampling is used in the phase of control or clarification of the identified error. The main purpose is to corroborate or measure the degree of risk detected following a pertinent analysis. Since the auditor does not have time or means to thoroughly rebuild the information, the sampling technique can provide an effective response to the need for valorization.

  15. Water stable isotope measurements of Antarctic samples by means of IRMS and WS-CRDS techniques

    Science.gov (United States)

    Michelini, Marzia; Bonazza, Mattia; Braida, Martina; Flora, Onelio; Dreossi, Giuliano; Stenni, Barbara

    2010-05-01

    In the last years in the scientific community there has been an increasing interest for the application of stable isotope techniques to several environmental problems such as drinking water safeguarding, groundwater management, climate change, soils and paleoclimate studies etc. For example, the water stable isotopes, being natural tracers of the hydrological cycle, have been extensively used as tools to characterize regional aquifers and to reconstruct past temperature changes from polar ice cores. Here the need for improvements in analytical techniques: the high request for information calls for technologies that can offer a great quantity of analyses in short times and with low costs. Furthermore, sometimes it is difficult to obtain big amount of samples (as is the case for Antarctic ice cores or interstitial water) preventing the possibility to replicate the analyses. Here, we present oxygen and hydrogen measurements performed on water samples covering a big range of isotopic values (from very negative antarctic precipitation to mid-latitude precipitation values) carried out with both the conventional Isotope Ratio Mass Spectrometry (IRMS) technique and with a new method based on laser absorption techniques, the Wavelenght Scanned Cavity Ringdown Spectroscopy (WS-CRDS). This study is focusing on improving the precision of the measurements carried out with WS-CRDS in order to extensively apply this method to Antarctic ice core paleoclimate studies. The WS-CRDS is a variation of the CRDS developed in 1988 by O'Keef and Deacon. In CRDS a pulse of light goes through a box with high reflective inner surfaces; when there is no sample in the box the light beam doesn't find any obstacle in its path, but the reflectivity of the walls is not perfect so eventually there will be an absorption of the light beam; when the sample is injected in the box there is absorption and the difference between the time of absorption without and with sample is proportional to the quantity

  16. Nuclear analytical techniques and their application to environmental samples

    International Nuclear Information System (INIS)

    Lieser, K.H.

    1986-01-01

    A survey is given on nuclear analytical techniques and their application to environmental samples. Measurement of the inherent radioactivity of elements or radionuclides allows determination of natural radioelements (e.g. Ra), man-made radioelements (e.g. Pu) and radionuclides in the environment. Activation analysis, in particular instrumental neutron activation analysis, is a very reliable and sensitive method for determination of a great number of trace elements in environmental samples, because the most abundant main constituents are not activated. Tracer techniques are very useful for studies of the behaviour and of chemical reactions of trace elements and compounds in the environment. Radioactive sources are mainly applied for excitation of characteristic X-rays (X-ray fluorescence analysis). (author)

  17. Micro and Nano Techniques for the Handling of Biological Samples

    DEFF Research Database (Denmark)

    Micro and Nano Techniques for the Handling of Biological Samples reviews the different techniques available to manipulate and integrate biological materials in a controlled manner, either by sliding them along a surface (2-D manipulation), or by gripping and moving them to a new position (3-D...

  18. Methodological integrative review of the work sampling technique used in nursing workload research.

    Science.gov (United States)

    Blay, Nicole; Duffield, Christine M; Gallagher, Robyn; Roche, Michael

    2014-11-01

    To critically review the work sampling technique used in nursing workload research. Work sampling is a technique frequently used by researchers and managers to explore and measure nursing activities. However, work sampling methods used are diverse making comparisons of results between studies difficult. Methodological integrative review. Four electronic databases were systematically searched for peer-reviewed articles published between 2002-2012. Manual scanning of reference lists and Rich Site Summary feeds from contemporary nursing journals were other sources of data. Articles published in the English language between 2002-2012 reporting on research which used work sampling to examine nursing workload. Eighteen articles were reviewed. The review identified that the work sampling technique lacks a standardized approach, which may have an impact on the sharing or comparison of results. Specific areas needing a shared understanding included the training of observers and subjects who self-report, standardization of the techniques used to assess observer inter-rater reliability, sampling methods and reporting of outcomes. Work sampling is a technique that can be used to explore the many facets of nursing work. Standardized reporting measures would enable greater comparison between studies and contribute to knowledge more effectively. Author suggestions for the reporting of results may act as guidelines for researchers considering work sampling as a research method. © 2014 John Wiley & Sons Ltd.

  19. Systematic comparison of static and dynamic headspace sampling techniques for gas chromatography.

    Science.gov (United States)

    Kremser, Andreas; Jochmann, Maik A; Schmidt, Torsten C

    2016-09-01

    Six automated, headspace-based sample preparation techniques were used to extract volatile analytes from water with the goal of establishing a systematic comparison between commonly available instrumental alternatives. To that end, these six techniques were used in conjunction with the same gas chromatography instrument for analysis of a common set of volatile organic carbon (VOC) analytes. The methods were thereby divided into three classes: static sampling (by syringe or loop), static enrichment (SPME and PAL SPME Arrow), and dynamic enrichment (ITEX and trap sampling). For PAL SPME Arrow, different sorption phase materials were also included in the evaluation. To enable an effective comparison, method detection limits (MDLs), relative standard deviations (RSDs), and extraction yields were determined and are discussed for all techniques. While static sampling techniques exhibited sufficient extraction yields (approx. 10-20 %) to be reliably used down to approx. 100 ng L(-1), enrichment techniques displayed extraction yields of up to 80 %, resulting in MDLs down to the picogram per liter range. RSDs for all techniques were below 27 %. The choice on one of the different instrumental modes of operation (aforementioned classes) was thereby the most influential parameter in terms of extraction yields and MDLs. Individual methods inside each class showed smaller deviations, and the least influences were observed when evaluating different sorption phase materials for the individual enrichment techniques. The option of selecting specialized sorption phase materials may, however, be more important when analyzing analytes with different properties such as high polarity or the capability of specific molecular interactions. Graphical Abstract PAL SPME Arrow during the extraction of volatile analytes from the headspace of an aqueous sample.

  20. RF Sub-sampling Receiver Architecture based on Milieu Adapting Techniques

    DEFF Research Database (Denmark)

    Behjou, Nastaran; Larsen, Torben; Jensen, Ole Kiel

    2012-01-01

    A novel sub-sampling based architecture is proposed which has the ability of reducing the problem of image distortion and improving the signal to noise ratio significantly. The technique is based on sensing the environment and adapting the sampling rate of the receiver to the best possible...

  1. Improved importance sampling technique for efficient simulation of digital communication systems

    Science.gov (United States)

    Lu, Dingqing; Yao, Kung

    1988-01-01

    A new, improved importance sampling (IIS) approach to simulation is considered. Some basic concepts of IS are introduced, and detailed evolutions of simulation estimation variances for Monte Carlo (MC) and IS simulations are given. The general results obtained from these evolutions are applied to the specific previously known conventional importance sampling (CIS) technique and the new IIS technique. The derivation for a linear system with no signal random memory is considered in some detail. For the CIS technique, the optimum input scaling parameter is found, while for the IIS technique, the optimum translation parameter is found. The results are generalized to a linear system with memory and signals. Specific numerical and simulation results are given which show the advantages of CIS over MC and IIS over CIS for simulations of digital communications systems.

  2. Cone penetrometer tests and HydroPunch sampling: A screening technique for plume definition

    International Nuclear Information System (INIS)

    Smolley, M.; Kappmeyer, J.C.

    1991-01-01

    Cone penetrometer tests and HydroPunch sampling were used to define the extent of volatile organic compounds in ground water. The investigation indicated that the combination of the these techniques is effective for obtaining ground water samples for preliminary plume definition. HydroPunch samples can be collected in unconsolidated sediments and the analytical results obtained from these samples are comparable to those obtained from adjacent monitoring wells. This sampling method is a rapid and cost-effective screening technique for characterizing the extent of contaminant plumes in soft sediment environments. Use of this screening technique allowed monitoring wells to be located at the plume boundary, thereby reducing the number of wells installed and the overall cost of the plume definition program

  3. Chance constrained problems: penalty reformulation and performance of sample approximation technique

    Czech Academy of Sciences Publication Activity Database

    Branda, Martin

    2012-01-01

    Roč. 48, č. 1 (2012), s. 105-122 ISSN 0023-5954 R&D Projects: GA ČR(CZ) GBP402/12/G097 Institutional research plan: CEZ:AV0Z10750506 Keywords : chance constrained problems * penalty functions * asymptotic equivalence * sample approximation technique * investment problem Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.619, year: 2012 http://library.utia.cas.cz/separaty/2012/E/branda-chance constrained problems penalty reformulation and performance of sample approximation technique.pdf

  4. Sampling methods and non-destructive examination techniques for large radioactive waste packages

    International Nuclear Information System (INIS)

    Green, T.H.; Smith, D.L.; Burgoyne, K.E.; Maxwell, D.J.; Norris, G.H.; Billington, D.M.; Pipe, R.G.; Smith, J.E.; Inman, C.M.

    1992-01-01

    Progress is reported on work undertaken to evaluate quality checking methods for radioactive wastes. A sampling rig was designed, fabricated and used to develop techniques for the destructive sampling of cemented simulant waste using remotely operated equipment. An engineered system for the containment of cooling water was designed and manufactured and successfully demonstrated with the drum and coring equipment mounted in both vertical and horizontal orientations. The preferred in-cell orientation was found to be with the drum and coring machinery mounted in a horizontal position. Small powdered samples can be taken from cemented homogeneous waste cores using a hollow drill/vacuum section technique with the preferred subsampling technique being to discard the outer 10 mm layer to obtain a representative sample of the cement core. Cement blends can be dissolved using fusion techniques and the resulting solutions are stable to gelling for periods in excess of one year. Although hydrochloric acid and nitric acid are promising solvents for dissolution of cement blends, the resultant solutions tend to form silicic acid gels. An estimate of the beta-emitter content of cemented waste packages can be obtained by a combination of non-destructive and destructive techniques. The errors will probably be in excess of +/-60 % at the 95 % confidence level. Real-time X-ray video-imaging techniques have been used to analyse drums of uncompressed, hand-compressed, in-drum compacted and high-force compacted (i.e. supercompacted) simulant waste. The results have confirmed the applicability of this technique for NDT of low-level waste. 8 refs., 12 figs., 3 tabs

  5. A Comparison of Soil-Water Sampling Techniques

    Science.gov (United States)

    Tindall, J. A.; Figueroa-Johnson, M.; Friedel, M. J.

    2007-12-01

    The representativeness of soil pore water extracted by suction lysimeters in ground-water monitoring studies is a problem that often confounds interpretation of measured data. Current soil water sampling techniques cannot identify the soil volume from which a pore water sample is extracted, neither macroscopic, microscopic, or preferential flowpath. This research was undertaken to compare values of extracted suction lysimeters samples from intact soil cores with samples obtained by the direct extraction methods to determine what portion of soil pore water is sampled by each method. Intact soil cores (30 centimeter (cm) diameter by 40 cm height) were extracted from two different sites - a sandy soil near Altamonte Springs, Florida and a clayey soil near Centralia in Boone County, Missouri. Isotopically labeled water (O18? - analyzed by mass spectrometry) and bromide concentrations (KBr- - measured using ion chromatography) from water samples taken by suction lysimeters was compared with samples obtained by direct extraction methods of centrifugation and azeotropic distillation. Water samples collected by direct extraction were about 0.25 ? more negative (depleted) than that collected by suction lysimeter values from a sandy soil and about 2-7 ? more negative from a well structured clayey soil. Results indicate that the majority of soil water in well-structured soil is strongly bound to soil grain surfaces and is not easily sampled by suction lysimeters. In cases where a sufficient volume of water has passed through the soil profile and displaced previous pore water, suction lysimeters will collect a representative sample of soil pore water from the sampled depth interval. It is suggested that for stable isotope studies monitoring precipitation and soil water, suction lysimeter should be installed at shallow depths (10 cm). Samples should also be coordinated with precipitation events. The data also indicate that each extraction method be use to sample a different

  6. Can groundwater sampling techniques used in monitoring wells influence methane concentrations and isotopes?

    Science.gov (United States)

    Rivard, Christine; Bordeleau, Geneviève; Lavoie, Denis; Lefebvre, René; Malet, Xavier

    2018-03-06

    Methane concentrations and isotopic composition in groundwater are the focus of a growing number of studies. However, concerns are often expressed regarding the integrity of samples, as methane is very volatile and may partially exsolve during sample lifting in the well and transfer to sampling containers. While issues concerning bottle-filling techniques have already been documented, this paper documents a comparison of methane concentration and isotopic composition obtained with three devices commonly used to retrieve water samples from dedicated observation wells. This work lies within the framework of a larger project carried out in the Saint-Édouard area (southern Québec, Canada), whose objective was to assess the risk to shallow groundwater quality related to potential shale gas exploitation. The selected sampling devices, which were tested on ten wells during three sampling campaigns, consist of an impeller pump, a bladder pump, and disposable sampling bags (HydraSleeve). The sampling bags were used both before and after pumping, to verify the appropriateness of a no-purge approach, compared to the low-flow approach involving pumping until stabilization of field physicochemical parameters. Results show that methane concentrations obtained with the selected sampling techniques are usually similar and that there is no systematic bias related to a specific technique. Nonetheless, concentrations can sometimes vary quite significantly (up to 3.5 times) for a given well and sampling event. Methane isotopic composition obtained with all sampling techniques is very similar, except in some cases where sampling bags were used before pumping (no-purge approach), in wells where multiple groundwater sources enter the borehole.

  7. Development of environmental sample analysis techniques for safeguards

    International Nuclear Information System (INIS)

    Magara, Masaaki; Hanzawa, Yukiko; Esaka, Fumitaka

    1999-01-01

    JAERI has been developing environmental sample analysis techniques for safeguards and preparing a clean chemistry laboratory with clean rooms. Methods to be developed are a bulk analysis and a particle analysis. In the bulk analysis, Inductively-Coupled Plasma Mass Spectrometer or Thermal Ionization Mass Spectrometer are used to measure nuclear materials after chemical treatment of sample. In the particle analysis, Electron Probe Micro Analyzer and Secondary Ion Mass Spectrometer are used for elemental analysis and isotopic analysis, respectively. The design of the clean chemistry laboratory has been carried out and construction will be completed by the end of March, 2001. (author)

  8. Standardization of proton-induced x-ray emission technique for analysis of thick samples

    Science.gov (United States)

    Ali, Shad; Zeb, Johar; Ahad, Abdul; Ahmad, Ishfaq; Haneef, M.; Akbar, Jehan

    2015-09-01

    This paper describes the standardization of the proton-induced x-ray emission (PIXE) technique for finding the elemental composition of thick samples. For the standardization, three different samples of standard reference materials (SRMs) were analyzed using this technique and the data were compared with the already known data of these certified SRMs. These samples were selected in order to cover the maximum range of elements in the periodic table. Each sample was irradiated for three different values of collected beam charges at three different times. A proton beam of 2.57 MeV obtained using 5UDH-II Pelletron accelerator was used for excitation of x-rays from the sample. The acquired experimental data were analyzed using the GUPIXWIN software. The results show that the SRM data and the data obtained using the PIXE technique are in good agreement.

  9. Review of sample preparation techniques for the analysis of pesticide residues in soil.

    Science.gov (United States)

    Tadeo, José L; Pérez, Rosa Ana; Albero, Beatriz; García-Valcárcel, Ana I; Sánchez-Brunete, Consuelo

    2012-01-01

    This paper reviews the sample preparation techniques used for the analysis of pesticides in soil. The present status and recent advances made during the last 5 years in these methods are discussed. The analysis of pesticide residues in soil requires the extraction of analytes from this matrix, followed by a cleanup procedure, when necessary, prior to their instrumental determination. The optimization of sample preparation is a very important part of the method development that can reduce the analysis time, the amount of solvent, and the size of samples. This review considers all aspects of sample preparation, including extraction and cleanup. Classical extraction techniques, such as shaking, Soxhlet, and ultrasonic-assisted extraction, and modern techniques like pressurized liquid extraction, microwave-assisted extraction, solid-phase microextraction and QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) are reviewed. The different cleanup strategies applied for the purification of soil extracts are also discussed. In addition, the application of these techniques to environmental studies is considered.

  10. Laboratory techniques for safe encapsulation of α-emitting powder samples

    International Nuclear Information System (INIS)

    Chamberlain, H.E.; Pottinger, J.S.

    1984-01-01

    Plutonium oxide powder samples can be encapsulated in thin plastic film to prevent spread of contamination in counting and X-ray diffraction equipment. The film has to be thin enough to transmit X-rays and α-particles. Techniques are described for the wrapping process and the precautions necessary to keep the sample processing line free of significant contamination. (author)

  11. Objective assessment of IP video calls with Asterisk

    OpenAIRE

    Kapičák, Lukáš; Nevlud, Pavel; Mikulec, Martin; Zdrálek, Jaroslav

    2012-01-01

    The paper deals with an objective assessment of IP video calls transmission over GSM and UMTS networks. Video transmission is affected by many factors in mobile network. Among these factors belong packet loss, latency and transmission rate of the mobile network. Network properties were simulated by Simena network simulator. Our team have developed a unique technique for finding defects in video appearing in video calls. This technique is built on modified Asterisk SW PBX with enabled video re...

  12. Techniques of sample attack used in soil and mineral analysis. Phase I

    International Nuclear Information System (INIS)

    Chiu, N.W.; Dean, J.R.; Sill, C.W.

    1984-07-01

    Several techniques of sample attack for the determination of radioisotopes are reviewed. These techniques include: 1) digestion with nitric or hydrochloric acid in Parr digestion bomb, 2) digestion with a mixture of nitric and hydrochloric acids, 3) digestion with a mixture of hydrofluoric, nitric and perchloric acids, and 4) fusion with sodium carbonate, potassium fluoride or alkali pyrosulfates. The effectiveness of these techniques to decompose various soils and minerals containing radioisotopes such as lead-210 uranium, thorium and radium-226 are discussed. The combined procedure of potassium fluoride fusion followed by alkali pyrosulfate fusion is recommended for radium-226, uranium and thorium analysis. This technique guarantees the complete dissolution of samples containing refractory materials such as silica, silicates, carbides, oxides and sulfates. For the lead-210 analysis, the procedure of digestion with a mixture of hydrofluoric, nitric and perchloric acids followed by fusion with alkali pyrosulfate is recommended. These two procedures are detailed. Schemes for the sequential separation of the radioisotopes from a dissolved sample solution are outlined. Procedures for radiochemical analysis are suggested

  13. Assessment of Natural Radioactivity in TENORM Samples Using Different Techniques

    International Nuclear Information System (INIS)

    Salman, Kh.A.; Shahein, A.Y.

    2009-01-01

    In petroleum oil industries, technologically-enhanced, naturally occurring radioactive materials are produced. The presence of TENORM constitutes a significant radiological human health hazard. In the present work, liquid scintillation counting technique was used to determine both 222 Rn and 226 Ra concentrations in TENORM samples, by measuring 222 Rn concentrations in the sample at different intervals of time after preparation. The radiation doses from the TENORM samples were estimated using thermoluminenscent detector (TLD-4000). The estimated radiation doses were found to be proportional to both the measured radiation doses in site and natural activity concentration in the samples that measured with LSC

  14. Review of online coupling of sample preparation techniques with liquid chromatography.

    Science.gov (United States)

    Pan, Jialiang; Zhang, Chengjiang; Zhang, Zhuomin; Li, Gongke

    2014-03-07

    Sample preparation is still considered as the bottleneck of the whole analytical procedure, and efforts has been conducted towards the automation, improvement of sensitivity and accuracy, and low comsuption of organic solvents. Development of online sample preparation techniques (SP) coupled with liquid chromatography (LC) is a promising way to achieve these goals, which has attracted great attention. This article reviews the recent advances on the online SP-LC techniques. Various online SP techniques have been described and summarized, including solid-phase-based extraction, liquid-phase-based extraction assisted with membrane, microwave assisted extraction, ultrasonic assisted extraction, accelerated solvent extraction and supercritical fluids extraction. Specially, the coupling approaches of online SP-LC systems and the corresponding interfaces have been discussed and reviewed in detail, such as online injector, autosampler combined with transport unit, desorption chamber and column switching. Typical applications of the online SP-LC techniques have been summarized. Then the problems and expected trends in this field are attempted to be discussed and proposed in order to encourage the further development of online SP-LC techniques. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Cleaning and Cleanliness Verification Techniques for Mars Returned Sample Handling

    Science.gov (United States)

    Mickelson, E. T.; Lindstrom, D. J.; Allton, J. H.; Hittle, J. D.

    2002-01-01

    Precision cleaning and cleanliness verification techniques are examined as a subset of a comprehensive contamination control strategy for a Mars sample return mission. Additional information is contained in the original extended abstract.

  16. Elemental analyses of goundwater: demonstrated advantage of low-flow sampling and trace-metal clean techniques over standard techniques

    Science.gov (United States)

    Creasey, C. L.; Flegal, A. R.

    The combined use of both (1) low-flow purging and sampling and (2) trace-metal clean techniques provides more representative measurements of trace-element concentrations in groundwater than results derived with standard techniques. The use of low-flow purging and sampling provides relatively undisturbed groundwater samples that are more representative of in situ conditions, and the use of trace-element clean techniques limits the inadvertent introduction of contaminants during sampling, storage, and analysis. When these techniques are applied, resultant trace-element concentrations are likely to be markedly lower than results based on standard sampling techniques. In a comparison of data derived from contaminated and control groundwater wells at a site in California, USA, trace-element concentrations from this study were 2-1000 times lower than those determined by the conventional techniques used in sampling of the same wells prior to (5months) and subsequent to (1month) the collections for this study. Specifically, the cadmium and chromium concentrations derived using standard sampling techniques exceed the California Maximum Contaminant Levels (MCL), whereas in this investigation concentrations of both of those elements are substantially below their MCLs. Consequently, the combined use of low-flow and trace-metal clean techniques may preclude erroneous reports of trace-element contamination in groundwater. Résumé L'utilisation simultanée de la purge et de l'échantillonnage à faible débit et des techniques sans traces de métaux permet d'obtenir des mesures de concentrations en éléments en traces dans les eaux souterraines plus représentatives que les résultats fournis par les techniques classiques. L'utilisation de la purge et de l'échantillonnage à faible débit donne des échantillons d'eau souterraine relativement peu perturbés qui sont plus représentatifs des conditions in situ, et le recours aux techniques sans éléments en traces limite l

  17. THE STUDY OF HEAVY METAL FROM ENVIRONMENTAL SAMPLES BY ATOMIC TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Ion V. POPESCU

    2011-05-01

    Full Text Available Using the Atomic Absorption Spectrometry (AAS and Energy Dispersive X-ray spectrometry (EDXRF techniques we analyzed the contents of heavy metals ( Cd, Cr, Ni, Pb, Ti, Sr, Co, Bi from eight wild mushrooms and soil substrate samples (48 samples of eight fungal species and 32 underlying soil samples, collected from ten forest sites of Dambovița County Romania. It was determined that the elements, especially heavy metals, in soil were characteristic of the acidic soils of the Romanian forest lands and are influenced by industrial pollution. Analytical possibilities of AAS and EDXRF analytical techniques have been compared and the heavy metal transfer from substrate to mushrooms has been studied. The coefficient of accumulation of essential and heavy metals has been calculated as well. Heavy metal contents of all analyzed mushrooms were generally higher than previously reported in literature.

  18. Comparison between correlated sampling and the perturbation technique of MCNP5 for fixed-source problems

    International Nuclear Information System (INIS)

    He Tao; Su Bingjing

    2011-01-01

    Highlights: → The performance of the MCNP differential operator perturbation technique is compared with that of the MCNP correlated sampling method for three types of fixed-source problems. → In terms of precision, the MCNP perturbation technique outperforms correlated sampling for one type of problem but performs comparably with or even under-performs correlated sampling for the other two types of problems. → In terms of accuracy, the MCNP perturbation calculations may predict inaccurate results for some of the test problems. However, the accuracy can be improved if the midpoint correction technique is used. - Abstract: Correlated sampling and the differential operator perturbation technique are two methods that enable MCNP (Monte Carlo N-Particle) to simulate small response change between an original system and a perturbed system. In this work the performance of the MCNP differential operator perturbation technique is compared with that of the MCNP correlated sampling method for three types of fixed-source problems. In terms of precision of predicted response changes, the MCNP perturbation technique outperforms correlated sampling for the problem involving variation of nuclide concentrations in the same direction but performs comparably with or even underperforms correlated sampling for the other two types of problems that involve void or variation of nuclide concentrations in opposite directions. In terms of accuracy, the MCNP differential operator perturbation calculations may predict inaccurate results that deviate from the benchmarks well beyond their uncertainty ranges for some of the test problems. However, the accuracy of the MCNP differential operator perturbation can be improved if the midpoint correction technique is used.

  19. A technique for extracting blood samples from mice in fire toxicity tests

    Science.gov (United States)

    Bucci, T. J.; Hilado, C. J.; Lopez, M. T.

    1976-01-01

    The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.

  20. Comparison of sampling techniques for Rift Valley Fever virus ...

    African Journals Online (AJOL)

    We investigated mosquito sampling techniques with two types of traps and attractants at different time for trapping potential vectors for Rift Valley Fever virus. The study was conducted in six villages in Ngorongoro district in Tanzania from September to October 2012. A total of 1814 mosquitoes were collected, of which 738 ...

  1. DNA base-calling from a nanopore using a Viterbi algorithm.

    Science.gov (United States)

    Timp, Winston; Comer, Jeffrey; Aksimentiev, Aleksei

    2012-05-16

    Nanopore-based DNA sequencing is the most promising third-generation sequencing method. It has superior read length, speed, and sample requirements compared with state-of-the-art second-generation methods. However, base-calling still presents substantial difficulty because the resolution of the technique is limited compared with the measured signal/noise ratio. Here we demonstrate a method to decode 3-bp-resolution nanopore electrical measurements into a DNA sequence using a Hidden Markov model. This method shows tremendous potential for accuracy (~98%), even with a poor signal/noise ratio. Copyright © 2012 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  2. A line-based vegetation sampling technique and its application in ...

    African Journals Online (AJOL)

    percentage cover, density and intercept frequency) and also provides plant size distributions, yet requires no more sampling effort than the line-intercept method.. A field test of the three techniques in succulent karoo, showed that the discriminating ...

  3. Comparison of correlation analysis techniques for irregularly sampled time series

    Directory of Open Access Journals (Sweden)

    K. Rehfeld

    2011-06-01

    Full Text Available Geoscientific measurements often provide time series with irregular time sampling, requiring either data reconstruction (interpolation or sophisticated methods to handle irregular sampling. We compare the linear interpolation technique and different approaches for analyzing the correlation functions and persistence of irregularly sampled time series, as Lomb-Scargle Fourier transformation and kernel-based methods. In a thorough benchmark test we investigate the performance of these techniques.

    All methods have comparable root mean square errors (RMSEs for low skewness of the inter-observation time distribution. For high skewness, very irregular data, interpolation bias and RMSE increase strongly. We find a 40 % lower RMSE for the lag-1 autocorrelation function (ACF for the Gaussian kernel method vs. the linear interpolation scheme,in the analysis of highly irregular time series. For the cross correlation function (CCF the RMSE is then lower by 60 %. The application of the Lomb-Scargle technique gave results comparable to the kernel methods for the univariate, but poorer results in the bivariate case. Especially the high-frequency components of the signal, where classical methods show a strong bias in ACF and CCF magnitude, are preserved when using the kernel methods.

    We illustrate the performances of interpolation vs. Gaussian kernel method by applying both to paleo-data from four locations, reflecting late Holocene Asian monsoon variability as derived from speleothem δ18O measurements. Cross correlation results are similar for both methods, which we attribute to the long time scales of the common variability. The persistence time (memory is strongly overestimated when using the standard, interpolation-based, approach. Hence, the Gaussian kernel is a reliable and more robust estimator with significant advantages compared to other techniques and suitable for large scale application to paleo-data.

  4. Application of nuclear and allied techniques for the characterisation of forensic samples

    International Nuclear Information System (INIS)

    Sudersanan, M.; Kayasth, S.R.; Pant, D.R.; Chattopadhyay, N.; Bhattacharyya, C.N.

    2002-01-01

    Full text: Forensic science deals with the application of various techniques for physics, chemistry and biology for crime investigation. The legal implication of such analysis put considerable restriction on the choice of analytical techniques. Moreover, the unknown nature of the materials, the limited availability of samples and the large number of elements to be analysed put considerable strain on the analytical chemist on the selection of the appropriate technique. The availability of nuclear techniques has considerably enhanced the scope of forensic analysis. This paper deals with the recent results on the use of nuclear and allied analytical techniques for forensic applications. One of the important types of samples of forensic importance pertain to the identification of gunshot residues. The use of nuclear techniques has considerably simplified the interpretation of results through the use of appropriate elements like Ba, Cu, Sb, Zn, As and Sn etc. The combination of non-nuclear techniques for elements like Pb and Ni which are not easily amenable to be analysed by NAA and the use of appropriate separation procedure has led to the use of this method as a valid and versatile analytical procedure. In view of the presence of a large amounts of extraneous materials like cloth, body tissues etc in these samples and the limited availability of materials, the procedures for sample collection, dissolution and analysis have been standardized. Analysis of unknown materials like powders, metallic pieces etc. for the possible presence of nuclear materials or as materials in illicit trafficking is becoming important in recent years. The use of multi-technique approach is important in this case. Use of non-destructive techniques like XRF and radioactive counting enables the preliminary identification of materials and for the detection of radioactivity. Subsequent analysis by NAA or other appropriate analytical methods allows the characterization of the materials. Such

  5. Call Forecasting for Inbound Call Center

    Directory of Open Access Journals (Sweden)

    Peter Vinje

    2009-01-01

    Full Text Available In a scenario of inbound call center customer service, the ability to forecast calls is a key element and advantage. By forecasting the correct number of calls a company can predict staffing needs, meet service level requirements, improve customer satisfaction, and benefit from many other optimizations. This project will show how elementary statistics can be used to predict calls for a specific company, forecast the rate at which calls are increasing/decreasing, and determine if the calls may stop at some point.

  6. Determination of palladium in biological samples applying nuclear analytical techniques

    International Nuclear Information System (INIS)

    Cavalcante, Cassio Q.; Sato, Ivone M.; Salvador, Vera L. R.; Saiki, Mitiko

    2008-01-01

    This study presents Pd determinations in bovine tissue samples containing palladium prepared in the laboratory, and CCQM-P63 automotive catalyst materials of the Proficiency Test, using instrumental thermal and epithermal neutron activation analysis and energy dispersive X-ray fluorescence techniques. Solvent extraction and solid phase extraction procedures were also applied to separate Pd from interfering elements before the irradiation in the nuclear reactor. The results obtained by different techniques were compared against each other to examine sensitivity, precision and accuracy. (author)

  7. A new sampling technique for surface exposure dating using a portable electric rock cutter

    Directory of Open Access Journals (Sweden)

    Yusuke Suganuma

    2012-07-01

    Full Text Available Surface exposure dating using in situ cosmogenic nuclides has contributed to our understanding of Earth-surface processes. The precision of the ages estimated by this method is affected by the sample geometry; therefore, high accuracy measurements of the thickness and shape of the rock sample (thickness and shape is crucial. However, it is sometimes diffi cult to meet these requirements by conventional sampling methods with a hammer and chisel. Here, we propose a new sampling technique using a portable electric rock cutter. This sampling technique is faster, produces more precisely shaped samples, and allows for a more precise age interpretation. A simple theoretical modeldemonstrates that the age error due to defective sample geometry increases as the total sample thickness increases, indicating the importance of precise sampling for surface exposure dating.

  8. Mantle biopsy: a technique for nondestructive tissue-sampling of freshwater mussels

    Science.gov (United States)

    David J. Berg; Wendell R. Haag; Sheldon I. Guttman; James B. Sickel

    1995-01-01

    Mantle biopsy is a means of obtaining tissue samples for genetic, physiological, and contaminant studies of bivalves; but the effects of this biopsy on survival have not been determined. We describe a simple technique for obtaining such samples from unionacean bivalves and how we compared survival among biopsied and control organisms in field experiments. Survival was...

  9. A Monte Carlo Sampling Technique for Multi-phonon Processes

    Energy Technology Data Exchange (ETDEWEB)

    Hoegberg, Thure

    1961-12-15

    A sampling technique for selecting scattering angle and energy gain in Monte Carlo calculations of neutron thermalization is described. It is supposed that the scattering is separated into processes involving different numbers of phonons. The number of phonons involved is first determined. Scattering angle and energy gain are then chosen by using special properties of the multi-phonon term.

  10. An empirical analysis of the corporate call decision

    International Nuclear Information System (INIS)

    Carlson, M.D.

    1998-01-01

    An economic study of the the behaviour of financial managers of utility companies was presented. The study examined whether or not an option pricing based model of the call decision does a better job of explaining callable preferred share prices and call decisions compared to other models. In this study, the Rust (1987) empirical technique was extended to include the use of information from preferred share prices in addition to the call decisions. Reasonable estimates were obtained from data of shares of the Pacific Gas and Electric Company (PGE) for the transaction costs associated with a call. It was concluded that the managers of the PGE clearly take into account the value of the option to delay the call when making their call decisions

  11. Evaluation of primary immunization coverage of infants under universal immunization programme in an urban area of bangalore city using cluster sampling and lot quality assurance sampling techniques.

    Science.gov (United States)

    K, Punith; K, Lalitha; G, Suman; Bs, Pradeep; Kumar K, Jayanth

    2008-07-01

    Is LQAS technique better than cluster sampling technique in terms of resources to evaluate the immunization coverage in an urban area? To assess and compare the lot quality assurance sampling against cluster sampling in the evaluation of primary immunization coverage. Population-based cross-sectional study. Areas under Mathikere Urban Health Center. Children aged 12 months to 23 months. 220 in cluster sampling, 76 in lot quality assurance sampling. Percentages and Proportions, Chi square Test. (1) Using cluster sampling, the percentage of completely immunized, partially immunized and unimmunized children were 84.09%, 14.09% and 1.82%, respectively. With lot quality assurance sampling, it was 92.11%, 6.58% and 1.31%, respectively. (2) Immunization coverage levels as evaluated by cluster sampling technique were not statistically different from the coverage value as obtained by lot quality assurance sampling techniques. Considering the time and resources required, it was found that lot quality assurance sampling is a better technique in evaluating the primary immunization coverage in urban area.

  12. TRAN-STAT: statistics for environmental studies, Number 22. Comparison of soil-sampling techniques for plutonium at Rocky Flats

    International Nuclear Information System (INIS)

    Gilbert, R.O.; Bernhardt, D.E.; Hahn, P.B.

    1983-01-01

    A summary of a field soil sampling study conducted around the Rocky Flats Colorado plant in May 1977 is preseted. Several different soil sampling techniques that had been used in the area were applied at four different sites. One objective was to comparethe average 239 - 240 Pu concentration values obtained by the various soil sampling techniques used. There was also interest in determining whether there are differences in the reproducibility of the various techniques and how the techniques compared with the proposed EPA technique of sampling to 1 cm depth. Statistically significant differences in average concentrations between the techniques were found. The differences could be largely related to the differences in sampling depth-the primary physical variable between the techniques. The reproducibility of the techniques was evaluated by comparing coefficients of variation. Differences between coefficients of variation were not statistically significant. Average (median) coefficients ranged from 21 to 42 percent for the five sampling techniques. A laboratory study indicated that various sample treatment and particle sizing techniques could increase the concentration of plutonium in the less than 10 micrometer size fraction by up to a factor of about 4 compared to the 2 mm size fraction

  13. Stratified source-sampling techniques for Monte Carlo eigenvalue analysis

    International Nuclear Information System (INIS)

    Mohamed, A.

    1998-01-01

    In 1995, at a conference on criticality safety, a special session was devoted to the Monte Carlo ''Eigenvalue of the World'' problem. Argonne presented a paper, at that session, in which the anomalies originally observed in that problem were reproduced in a much simplified model-problem configuration, and removed by a version of stratified source-sampling. In this paper, stratified source-sampling techniques are generalized and applied to three different Eigenvalue of the World configurations which take into account real-world statistical noise sources not included in the model problem, but which differ in the amount of neutronic coupling among the constituents of each configuration. It is concluded that, in Monte Carlo eigenvalue analysis of loosely-coupled arrays, the use of stratified source-sampling reduces the probability of encountering an anomalous result over that if conventional source-sampling methods are used. However, this gain in reliability is substantially less than that observed in the model-problem results

  14. Evaluation of primary immunization coverage of infants under universal immunization programme in an urban area of Bangalore city using cluster sampling and lot quality assurance sampling techniques

    Directory of Open Access Journals (Sweden)

    Punith K

    2008-01-01

    Full Text Available Research Question: Is LQAS technique better than cluster sampling technique in terms of resources to evaluate the immunization coverage in an urban area? Objective: To assess and compare the lot quality assurance sampling against cluster sampling in the evaluation of primary immunization coverage. Study Design: Population-based cross-sectional study. Study Setting: Areas under Mathikere Urban Health Center. Study Subjects: Children aged 12 months to 23 months. Sample Size: 220 in cluster sampling, 76 in lot quality assurance sampling. Statistical Analysis: Percentages and Proportions, Chi square Test. Results: (1 Using cluster sampling, the percentage of completely immunized, partially immunized and unimmunized children were 84.09%, 14.09% and 1.82%, respectively. With lot quality assurance sampling, it was 92.11%, 6.58% and 1.31%, respectively. (2 Immunization coverage levels as evaluated by cluster sampling technique were not statistically different from the coverage value as obtained by lot quality assurance sampling techniques. Considering the time and resources required, it was found that lot quality assurance sampling is a better technique in evaluating the primary immunization coverage in urban area.

  15. Analytical techniques for measurement of 99Tc in environmental samples

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Three new methods have been developed for measuring 99 Tc in environmental samples. The most sensitive method is isotope dilution mass spectrometry, which allows measurement of about 1 x 10 -12 grams of 99 Tc. Results on analysis of five samples by this method compare very well with values obtained by a second independent method, which involves counting of beta particles from 99 Tc and internal conversion electrons from /sup 97m/Tc. A third method involving electrothermal atomic absorption has also been developed. Although this method is not as sensitive as the first two techniques, the cost per analysis is expected to be considerably less for certain types of samples

  16. Determination of some trace elements in biological samples using XRF and TXRF techniques

    International Nuclear Information System (INIS)

    Khuder, A.; Karjou, J.; Sawan, M. K.

    2006-07-01

    XRF and TXRF techniques were successfully used for the multi-element determination of trace elements in whole blood and human head hair samples. This was achieved by the direct analysis using XRF technique with different collimation units and by the optimized chemical procedures for TXRF analysis. Light element of S and P were preferably determined by XRF with primary x-ray excitation, while, elements of K, Ca, Fe, and Br were determined with a very good accuracy and precision using XRF with Cu- and Mo-secondary targets. The chemical procedure dependent on the preconcentration of trace elements by APDC was superiorly used for the determination of traces of Ni and Pb in the range of 1.0-1.7 μg/dl and 11-23 μg/dl, respectively, in whole blood samples by TXRF technique; determination of other elements as Cu and Zn was also achievable using this approach. Rb in whole blood samples was determined directly after the digestion of samples using PTFE-bomb for TXRF analysis. (author)

  17. Recent advances in sample preparation techniques and methods of sulfonamides detection - A review.

    Science.gov (United States)

    Dmitrienko, Stanislava G; Kochuk, Elena V; Apyari, Vladimir V; Tolmacheva, Veronika V; Zolotov, Yury A

    2014-11-19

    Sulfonamides (SAs) have been the most widely used antimicrobial drugs for more than 70 years, and their residues in foodstuffs and environmental samples pose serious health hazards. For this reason, sensitive and specific methods for the quantification of these compounds in numerous matrices have been developed. This review intends to provide an updated overview of the recent trends over the past five years in sample preparation techniques and methods for detecting SAs. Examples of the sample preparation techniques, including liquid-liquid and solid-phase extraction, dispersive liquid-liquid microextraction and QuEChERS, are given. Different methods of detecting the SAs present in food and feed and in environmental, pharmaceutical and biological samples are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Symbol synchronization and sampling frequency synchronization techniques in real-time DDO-OFDM systems

    Science.gov (United States)

    Chen, Ming; He, Jing; Cao, Zizheng; Tang, Jin; Chen, Lin; Wu, Xian

    2014-09-01

    In this paper, we propose and experimentally demonstrate a symbol synchronization and sampling frequency synchronization techniques in real-time direct-detection optical orthogonal frequency division multiplexing (DDO-OFDM) system, over 100-km standard single mode fiber (SSMF) using a cost-effective directly modulated distributed feedback (DFB) laser. The experiment results show that the proposed symbol synchronization based on training sequence (TS) has a low complexity and high accuracy even at a sampling frequency offset (SFO) of 5000-ppm. Meanwhile, the proposed pilot-assisted sampling frequency synchronization between digital-to-analog converter (DAC) and analog-to-digital converter (ADC) is capable of estimating SFOs with an accuracy of technique can also compensate SFO effects within a small residual SFO caused by deviation of SFO estimation and low-precision or unstable clock source. The two synchronization techniques are suitable for high-speed DDO-OFDM transmission systems.

  19. ANALYSIS OF MONTE CARLO SIMULATION SAMPLING TECHNIQUES ON SMALL SIGNAL STABILITY OF WIND GENERATOR- CONNECTED POWER SYSTEM

    Directory of Open Access Journals (Sweden)

    TEMITOPE RAPHAEL AYODELE

    2016-04-01

    Full Text Available Monte Carlo simulation using Simple Random Sampling (SRS technique is popularly known for its ability to handle complex uncertainty problems. However, to produce a reasonable result, it requires huge sample size. This makes it to be computationally expensive, time consuming and unfit for online power system applications. In this article, the performance of Latin Hypercube Sampling (LHS technique is explored and compared with SRS in term of accuracy, robustness and speed for small signal stability application in a wind generator-connected power system. The analysis is performed using probabilistic techniques via eigenvalue analysis on two standard networks (Single Machine Infinite Bus and IEEE 16–machine 68 bus test system. The accuracy of the two sampling techniques is determined by comparing their different sample sizes with the IDEAL (conventional. The robustness is determined based on a significant variance reduction when the experiment is repeated 100 times with different sample sizes using the two sampling techniques in turn. Some of the results show that sample sizes generated from LHS for small signal stability application produces the same result as that of the IDEAL values starting from 100 sample size. This shows that about 100 sample size of random variable generated using LHS method is good enough to produce reasonable results for practical purpose in small signal stability application. It is also revealed that LHS has the least variance when the experiment is repeated 100 times compared to SRS techniques. This signifies the robustness of LHS over that of SRS techniques. 100 sample size of LHS produces the same result as that of the conventional method consisting of 50000 sample size. The reduced sample size required by LHS gives it computational speed advantage (about six times over the conventional method.

  20. Modified emission-transmission method for determining trace elements in solid samples using the XRF techniques

    International Nuclear Information System (INIS)

    Poblete, V.; Alvarez, M.; Hermosilla, M.

    2000-01-01

    This is a study of an analysis of trace elements in medium thick solid samples, by the modified transmission emission method, using the energy dispersion X-ray fluorescence technique (EDXRF). The effects of absorption and reinforcement are the main disadvantages of the EDXRF technique for the quantitative analysis of bigger elements and trace elements in solid samples. The implementation of this method and its application to a variety of samples was carried out using an infinitely thick multi-element white sample that calculates the correction factors by absorbing all the analytes in the sample. The discontinuities in the masic absorption coefficients versus energies association for each element, with medium thick and homogenous samples, are analyzed and corrected. A thorough analysis of the different theoretical and test variables are proven by using real samples, including certified material with known concentration. The simplicity of the calculation method and the results obtained show the method's major precision, with possibilities for the non-destructive routine analysis of different solid samples, using the EDXRF technique (author)

  1. Recent Trends in Microextraction Techniques Employed in Analytical and Bioanalytical Sample Preparation

    Directory of Open Access Journals (Sweden)

    Abuzar Kabir

    2017-12-01

    Full Text Available Sample preparation has been recognized as a major step in the chemical analysis workflow. As such, substantial efforts have been made in recent years to simplify the overall sample preparation process. Major focusses of these efforts have included miniaturization of the extraction device; minimizing/eliminating toxic and hazardous organic solvent consumption; eliminating sample pre-treatment and post-treatment steps; reducing the sample volume requirement; reducing extraction equilibrium time, maximizing extraction efficiency etc. All these improved attributes are congruent with the Green Analytical Chemistry (GAC principles. Classical sample preparation techniques such as solid phase extraction (SPE and liquid-liquid extraction (LLE are being rapidly replaced with emerging miniaturized and environmentally friendly techniques such as Solid Phase Micro Extraction (SPME, Stir bar Sorptive Extraction (SBSE, Micro Extraction by Packed Sorbent (MEPS, Fabric Phase Sorptive Extraction (FPSE, and Dispersive Liquid-Liquid Micro Extraction (DLLME. In addition to the development of many new generic extraction sorbents in recent years, a large number of molecularly imprinted polymers (MIPs created using different template molecules have also enriched the large cache of microextraction sorbents. Application of nanoparticles as high-performance extraction sorbents has undoubtedly elevated the extraction efficiency and method sensitivity of modern chromatographic analyses to a new level. Combining magnetic nanoparticles with many microextraction sorbents has opened up new possibilities to extract target analytes from sample matrices containing high volumes of matrix interferents. The aim of the current review is to critically audit the progress of microextraction techniques in recent years, which has indisputably transformed the analytical chemistry practices, from biological and therapeutic drug monitoring to the environmental field; from foods to phyto

  2. Development of core sampling technique for ITER Type B radwaste

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. G.; Hong, K. P.; Oh, W. H.; Park, M. C.; Jung, S. H.; Ahn, S. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Type B radwaste (intermediate level and long lived radioactive waste) imported from ITER vacuum vessel are to be treated and stored in basement of hot cell building. The Type B radwaste treatment process is composed of buffer storage, cutting, sampling/tritium measurement, tritium removal, characterization, pre-packaging, inspection/decontamination, and storage etc. The cut slices of Type B radwaste components generated from cutting process undergo sampling process before and after tritium removal process. The purpose of sampling is to obtain small pieces of samples in order to investigate the tritium content and concentration of Type B radwaste. Core sampling, which is the candidates of sampling technique to be applied to ITER hot cell, is available for not thick (less than 50 mm) metal without use of coolant. Experimented materials were SS316L and CuCrZr in order to simulate ITER Type B radwaste. In core sampling, substantial secondary wastes from cutting chips will be produced unavoidably. Thus, core sampling machine will have to be equipped with disposal system such as suction equipment. Core sampling is considered an unfavorable method for tool wear compared to conventional drilling.

  3. 3D-Laser-Scanning Technique Applied to Bulk Density Measurements of Apollo Lunar Samples

    Science.gov (United States)

    Macke, R. J.; Kent, J. J.; Kiefer, W. S.; Britt, D. T.

    2015-01-01

    In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible

  4. Analysis of pure and malachite green doped polysulfone sample using FT-IR technique

    Science.gov (United States)

    Nayak, Rashmi J.; Khare, P. K.; Nayak, J. G.

    2018-05-01

    The sample of pure and malachite green doped Polysulfone in the form of foil was prepared by isothermal immersion technique. For the preparation of pure sample 4 gm of Polysulfone was dissolved in 50 ml of Dimethyl farmamide (DMF) solvent, while for the preparation of doped sample 10 mg, 50 mg and 100 mg Malachite Green was mixed with 4 gm of Polysulfone respectively. For the study of structural characterization of these pure and doped sample, Fourier Transform Infra-Red Spectroscopy (FT-IR) technique was used. This study shows that the intensity of transmittance decreases as the ratio of doping increases in pure polysulfone. The reduction in intensity of transmittance is clearly apparent in the present case more over the bands were broader which indicates towards charge transfer interaction between the donar and acceptor molecule.

  5. Separation Techniques for Quantification of Radionuclides in Environmental Samples

    Directory of Open Access Journals (Sweden)

    Dusan Galanda

    2009-01-01

    Full Text Available The reliable and quantitative measurement of radionuclides is important in order to determine environmental quality and radiation safety, and to monitor regulatory compliance. We examined soil samples from Podunajske Biskupice, near the city of Bratislava in the Slovak Republic, for the presence of several natural (238U, 232Th, 40K and anthropogenic (137Cs, 90Sr, 239Pu, 240Pu, 241Am radionuclides. The area is adjacent to a refinery and hazardous waste processing center, as well as the municipal incinerator plant, and so might possess an unusually high level of ecotoxic metals. We found that the levels of both naturally occurring and anthropogenic radionuclides fell within the expected ranges, indicating that these facilities pose no radiological threat to the local environment. During the course of our analysis, we modified existing techniques in order to allow us to handle the unusually large and complex samples that were needed to determine the levels of 239Pu, 240Pu, and 241Am activity. We also rated three commercial techniques for the separation of 90Sr from aqueous solutions and found that two of them, AnaLig Sr-01 and Empore Extraction Disks, were suitable for the quantitative and reliable separation of 90Sr, while the third, Sr-Spec Resin, was less so. The main criterion in evaluating these methods was the chemical recovery of 90Sr, which was less than we had expected. We also considered speed of separation and additional steps needed to prepare the sample for separation.

  6. Accelerated Solvent Extraction: An Innovative Sample Extraction Technique for Natural Products

    International Nuclear Information System (INIS)

    Hazlina Ahmad Hassali; Azfar Hanif Abd Aziz; Rosniza Razali

    2015-01-01

    Accelerated solvent extraction (ASE) is one of the novel techniques that have been developed for the extraction of phytochemicals from plants in order to shorten the extraction time, decrease the solvent consumption, increase the extraction yield and enhance the quality of extracts. This technique combines elevated temperatures and pressure with liquid solvents. This paper gives a brief overview of accelerated solvent extraction technique for sample preparation and its application to the extraction of natural products. Through practical examples, the effects of operational parameters such as temperature, volume of solvent used, extraction time and extraction yields on the performance of ASE are discussed. It is demonstrated that ASE technique allows reduced solvent consumption and shorter extraction time, while the extraction yields are even higher than those obtained with conventional methods. (author)

  7. Practical aspects of the resin bead technique for mass spectrometric sample loading

    International Nuclear Information System (INIS)

    Walker, R.L.; Pritchard, C.A.; Carter, J.A.; Smith, D.H.

    1976-07-01

    Using an anion resin bead as a loading vehicle for uranium and plutonium samples which are to be analyzed isotopically in a mass spectrometer has many advantages over conventional techniques. It is applicable to any laboratory routinely performing such analyses, but should be particularly relevant for Safeguards' purposes. Because the techniques required differ markedly from those of conventional methods, this report has been written to describe them in detail to enable those unfamiliar with the technique to master it with a minimum of trouble

  8. Neutron activation analysis of certified samples by the absolute method

    Science.gov (United States)

    Kadem, F.; Belouadah, N.; Idiri, Z.

    2015-07-01

    The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.

  9. A fully blanketed early B star LTE model atmosphere using an opacity sampling technique

    International Nuclear Information System (INIS)

    Phillips, A.P.; Wright, S.L.

    1980-01-01

    A fully blanketed LTE model of a stellar atmosphere with Tsub(e) = 21914 K (thetasub(e) = 0.23), log g = 4 is presented. The model includes an explicit representation of the opacity due to the strongest lines, and uses a statistical opacity sampling technique to represent the weaker line opacity. The sampling technique is subjected to several tests and the model is compared with an atmosphere calculated using the line-distribution function method. The limitations of the distribution function method and the particular opacity sampling method used here are discussed in the light of the results obtained. (author)

  10. Call cultures in orang-utans?

    Directory of Open Access Journals (Sweden)

    Serge A Wich

    Full Text Available BACKGROUND: Several studies suggested great ape cultures, arguing that human cumulative culture presumably evolved from such a foundation. These focused on conspicuous behaviours, and showed rich geographic variation, which could not be attributed to known ecological or genetic differences. Although geographic variation within call types (accents has previously been reported for orang-utans and other primate species, we examine geographic variation in the presence/absence of discrete call types (dialects. Because orang-utans have been shown to have geographic variation that is not completely explicable by genetic or ecological factors we hypothesized that this will be similar in the call domain and predict that discrete call type variation between populations will be found. METHODOLOGY/PRINCIPAL FINDINGS: We examined long-term behavioural data from five orang-utan populations and collected fecal samples for genetic analyses. We show that there is geographic variation in the presence of discrete types of calls. In exactly the same behavioural context (nest building and infant retrieval, individuals in different wild populations customarily emit either qualitatively different calls or calls in some but not in others. By comparing patterns in call-type and genetic similarity, we suggest that the observed variation is not likely to be explained by genetic or ecological differences. CONCLUSION/SIGNIFICANCE: These results are consistent with the potential presence of 'call cultures' and suggest that wild orang-utans possess the ability to invent arbitrary calls, which spread through social learning. These findings differ substantially from those that have been reported for primates before. First, the results reported here are on dialect and not on accent. Second, this study presents cases of production learning whereas most primate studies on vocal learning were cases of contextual learning. We conclude with speculating on how these findings might

  11. Sample preparation techniques based on combustion reactions in closed vessels - A brief overview and recent applications

    International Nuclear Information System (INIS)

    Flores, Erico M.M.; Barin, Juliano S.; Mesko, Marcia F.; Knapp, Guenter

    2007-01-01

    In this review, a general discussion of sample preparation techniques based on combustion reactions in closed vessels is presented. Applications for several kinds of samples are described, taking into account the literature data reported in the last 25 years. The operational conditions as well as the main characteristics and drawbacks are discussed for bomb combustion, oxygen flask and microwave-induced combustion (MIC) techniques. Recent applications of MIC techniques are discussed with special concern for samples not well digested by conventional microwave-assisted wet digestion as, for example, coal and also for subsequent determination of halogens

  12. Turchin's Relation for Call-by-Name Computations: A Formal Approach

    OpenAIRE

    Antonina Nepeivoda

    2016-01-01

    Supercompilation is a program transformation technique that was first described by V. F. Turchin in the 1970s. In supercompilation, Turchin's relation as a similarity relation on call-stack configurations is used both for call-by-value and call-by-name semantics to terminate unfolding of the program being transformed. In this paper, we give a formal grammar model of call-by-name stack behaviour. We classify the model in terms of the Chomsky hierarchy and then formally prove that Turchin's rel...

  13. The application of statistical and/or non-statistical sampling techniques by internal audit functions in the South African banking industry

    Directory of Open Access Journals (Sweden)

    D.P. van der Nest

    2015-03-01

    Full Text Available This article explores the use by internal audit functions of audit sampling techniques in order to test the effectiveness of controls in the banking sector. The article focuses specifically on the use of statistical and/or non-statistical sampling techniques by internal auditors. The focus of the research for this article was internal audit functions in the banking sector of South Africa. The results discussed in the article indicate that audit sampling is still used frequently as an audit evidence-gathering technique. Non-statistical sampling techniques are used more frequently than statistical sampling techniques for the evaluation of the sample. In addition, both techniques are regarded as important for the determination of the sample size and the selection of the sample items

  14. Latin hypercube sampling with inequality constraints

    International Nuclear Information System (INIS)

    Iooss, B.; Petelet, M.; Asserin, O.; Loredo, A.

    2010-01-01

    In some studies requiring predictive and CPU-time consuming numerical models, the sampling design of the model input variables has to be chosen with caution. For this purpose, Latin hypercube sampling has a long history and has shown its robustness capabilities. In this paper we propose and discuss a new algorithm to build a Latin hypercube sample (LHS) taking into account inequality constraints between the sampled variables. This technique, called constrained Latin hypercube sampling (cLHS), consists in doing permutations on an initial LHS to honor the desired monotonic constraints. The relevance of this approach is shown on a real example concerning the numerical welding simulation, where the inequality constraints are caused by the physical decreasing of some material properties in function of the temperature. (authors)

  15. X-ray spectrometry and X-ray microtomography techniques for soil and geological samples analysis

    International Nuclear Information System (INIS)

    Kubala-Kukuś, A.; Banaś, D.; Braziewicz, J.; Dziadowicz, M.; Kopeć, E.; Majewska, U.; Mazurek, M.; Pajek, M.; Sobisz, M.; Stabrawa, I.; Wudarczyk-Moćko, J.; Góźdź, S.

    2015-01-01

    A particular subject of X-ray fluorescence analysis is its application in studies of the multielemental sample of composition in a wide range of concentrations, samples with different matrices, also inhomogeneous ones and those characterized with different grain size. Typical examples of these kinds of samples are soil or geological samples for which XRF elemental analysis may be difficult due to XRF disturbing effects. In this paper the WDXRF technique was applied in elemental analysis concerning different soil and geological samples (therapeutic mud, floral soil, brown soil, sandy soil, calcium aluminum cement). The sample morphology was analyzed using X-ray microtomography technique. The paper discusses the differences between the composition of samples, the influence of procedures with respect to the preparation of samples as regards their morphology and, finally, a quantitative analysis. The results of the studies were statistically tested (one-way ANOVA and correlation coefficients). For lead concentration determination in samples of sandy soil and cement-like matrix, the WDXRF spectrometer calibration was performed. The elemental analysis of the samples was complemented with knowledge of chemical composition obtained by X-ray powder diffraction.

  16. X-ray spectrometry and X-ray microtomography techniques for soil and geological samples analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kubala-Kukuś, A.; Banaś, D.; Braziewicz, J. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Dziadowicz, M.; Kopeć, E. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Majewska, U. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Mazurek, M.; Pajek, M.; Sobisz, M.; Stabrawa, I. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Wudarczyk-Moćko, J. [Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Góźdź, S. [Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Institute of Public Health, Jan Kochanowski University, IX Wieków Kielc 19, 25-317 Kielce (Poland)

    2015-12-01

    A particular subject of X-ray fluorescence analysis is its application in studies of the multielemental sample of composition in a wide range of concentrations, samples with different matrices, also inhomogeneous ones and those characterized with different grain size. Typical examples of these kinds of samples are soil or geological samples for which XRF elemental analysis may be difficult due to XRF disturbing effects. In this paper the WDXRF technique was applied in elemental analysis concerning different soil and geological samples (therapeutic mud, floral soil, brown soil, sandy soil, calcium aluminum cement). The sample morphology was analyzed using X-ray microtomography technique. The paper discusses the differences between the composition of samples, the influence of procedures with respect to the preparation of samples as regards their morphology and, finally, a quantitative analysis. The results of the studies were statistically tested (one-way ANOVA and correlation coefficients). For lead concentration determination in samples of sandy soil and cement-like matrix, the WDXRF spectrometer calibration was performed. The elemental analysis of the samples was complemented with knowledge of chemical composition obtained by X-ray powder diffraction.

  17. Sampling methods for rumen microbial counts by Real-Time PCR techniques

    Directory of Open Access Journals (Sweden)

    S. Puppo

    2010-02-01

    Full Text Available Fresh rumen samples were withdrawn from 4 cannulated buffalo females fed a fibrous diets in order to quantify bacteria concentration in the rumen by Real-Time PCR techniques. To obtain DNA of a good quality from whole rumen fluid, eight (M1-M8 different pre-filtration methods (cheese cloths, glass-fibre and nylon filter in combination with various centrifugation speeds (1000, 5000 and 14,000 rpm were tested. Genomic DNA extraction was performed either on fresh or frozen samples (-20°C. The quantitative bacteria analysis was realized according to Real-Time PCR procedure for Butyrivibrio fibrisolvens reported in literature. M5 resulted the best sampling procedure allowing to obtain a suitable genomic DNA. No differences were revealed between fresh and frozen samples.

  18. Principles, Techniques, and Applications of Tissue Microfluidics

    Science.gov (United States)

    Wade, Lawrence A.; Kartalov, Emil P.; Shibata, Darryl; Taylor, Clive

    2011-01-01

    The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called "tissue microfluidics" because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets.

  19. Random sampling technique for ultra-fast computations of molecular opacities for exoplanet atmospheres

    Science.gov (United States)

    Min, M.

    2017-10-01

    Context. Opacities of molecules in exoplanet atmospheres rely on increasingly detailed line-lists for these molecules. The line lists available today contain for many species up to several billions of lines. Computation of the spectral line profile created by pressure and temperature broadening, the Voigt profile, of all of these lines is becoming a computational challenge. Aims: We aim to create a method to compute the Voigt profile in a way that automatically focusses the computation time into the strongest lines, while still maintaining the continuum contribution of the high number of weaker lines. Methods: Here, we outline a statistical line sampling technique that samples the Voigt profile quickly and with high accuracy. The number of samples is adjusted to the strength of the line and the local spectral line density. This automatically provides high accuracy line shapes for strong lines or lines that are spectrally isolated. The line sampling technique automatically preserves the integrated line opacity for all lines, thereby also providing the continuum opacity created by the large number of weak lines at very low computational cost. Results: The line sampling technique is tested for accuracy when computing line spectra and correlated-k tables. Extremely fast computations ( 3.5 × 105 lines per second per core on a standard current day desktop computer) with high accuracy (≤1% almost everywhere) are obtained. A detailed recipe on how to perform the computations is given.

  20. Sample preparation techniques in trace element analysis by X-ray emission spectroscopy

    International Nuclear Information System (INIS)

    Valkovic, V.

    1983-11-01

    The report, written under a research contract with the IAEA, contains a detailed presentation of the most difficult problem encountered in the trace element analysis by methods of the X-ray emission spectroscopy, namely the sample preparation techniques. The following items are covered. Sampling - with specific consideration of aerosols, water, soil, biological materials, petroleum and its products, storage of samples and their handling. Pretreatment of samples - preconcentration, ashing, solvent extraction, ion exchange and electrodeposition. Sample preparations for PIXE - analysis - backings, target uniformity and homogeneity, effects of irradiation, internal standards and specific examples of preparation (aqueous, biological, blood serum and solid samples). Sample preparations for radioactive sources or tube excitation - with specific examples (water, liquid and solid samples, soil, geological, plants and tissue samples). Finally, the problem of standards and reference materials, as well as that of interlaboratory comparisons, is discussed

  1. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis

    Science.gov (United States)

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-01

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH4+ strategy for ethylene and SO2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO2 from fruits. It was satisfied that trace ethylene and SO2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO2 during the entire LVCC sampling process were proved to be samples were achieved in range of 95.0-101% and 97.0-104% respectively. It is expected that portable LVCC sampling technique would pave the way for rapid on-site analysis of accurate concentrations of trace gas targets from real samples by SERS.

  2. Classification of sand samples according to radioactivity content by the use of euclidean and rough sets techniques

    International Nuclear Information System (INIS)

    Abd El-Monsef, M.M.; Kozae, A.M.; Seddeek, M.K.; Medhat, T.; Sharshar, T.; Badran, H.M.

    2004-01-01

    Form the geological point of view, the origin and transport of black and normal sands is particularly important. Black and normal sands came to their places along the Mediterranean-sea coast after transport by some natural process. Both types of sands have different radiological properties. This study is, therefore, attempts to use mathematical methods to classify Egyptian sand samples collected from 42 locations in an area of 40 x 19 km 2 based on their radioactivity contents. The use of all information resulted from the experimental measurements of radioactivity contents as well as some other parameters can be a time and effort consuming task. So that the process of eliminating unnecessary attributes is of prime importance. This elimination process of the superfluous attributes that cannot affect the decision was carried out. Some topological techniques to classify the information systems resulting from the radioactivity measurements were then carried out. These techniques were applied in Euclidean and quasi-discrete topological cases. While there are some applications in environmental radioactivity of the former case, the use of the quasi-discrete in the so-called rough set information analysis is new in such a study. The mathematical methods are summarized and the results and their radiological implications are discussed. Generally, the results indicate no radiological anomaly and it supports the hypothesis previously suggested about the presence of two types of sand in the studied area

  3. Turchin's Relation for Call-by-Name Computations: A Formal Approach

    Directory of Open Access Journals (Sweden)

    Antonina Nepeivoda

    2016-07-01

    Full Text Available Supercompilation is a program transformation technique that was first described by V. F. Turchin in the 1970s. In supercompilation, Turchin's relation as a similarity relation on call-stack configurations is used both for call-by-value and call-by-name semantics to terminate unfolding of the program being transformed. In this paper, we give a formal grammar model of call-by-name stack behaviour. We classify the model in terms of the Chomsky hierarchy and then formally prove that Turchin's relation can terminate all computations generated by the model.

  4. Reducing juvenile delinquency with automated cell phone calls.

    Science.gov (United States)

    Burraston, Bert O; Bahr, Stephen J; Cherrington, David J

    2014-05-01

    Using a sample of 70 juvenile probationers (39 treatment and 31 controls), we evaluated the effectiveness of a rehabilitation program that combined cognitive-behavioral training and automated phone calls. The cognitive-behavioral training contained six 90-min sessions, one per week, and the phone calls occurred twice per day for the year following treatment. Recidivism was measured by whether they were rearrested and the total number of rearrests during the 1st year. To test the impact of the phone calls, those who received phone calls were divided into high and low groups depending on whether they answered more or less than half of their phone calls. Those who completed the class and answered at least half of their phone calls were less likely to have been arrested and had fewer total arrests.

  5. Ion-trap tandem mass spectrometry. A reliable technique for the analysis of PCDD/Fs and dioxin-like PCBs in food and feed samples

    Energy Technology Data Exchange (ETDEWEB)

    Santos, F J; Malavia, J; Galceran, M T [Barcelona Univ. (Spain). Dept. of Analytical Chemistry; Abalos, M; Abad, E; Rivera, J [Mass Spectrometry Laboratory, Dept. of Ecotechnologies, IIQAB-CSIC, Barcelona (Spain)

    2004-09-15

    The recent establishment of maximum residue limits for polychlorodibenzo-pdioxins (PCDDs) and dibenzofurans (PCDFs) in food and feed samples by the European Community and the future inclusion of dioxin-like polychlorinated biphenyls (dl-PCBs) in these values at the end of 2006, has led to an important increase on the routine analysis of these compounds. Therefore, there is a clear need to have powerful sensitive and selective methods for the analysis of these compounds at low concentration levels. Actually, gas chromatography coupled with high resolution mass spectrometry (GC-HRMS) is the technique of reference for the determination of these analytes in environmental and food samples due to its high sensitivity and selectivity. Nevertheless, this technique is relatively expensive and requires qualifier personnel. Therefore, the development of more economical but reliable methods that can deliver results comparable to GC-HRMS is required. During the last years, gas chromatography coupled with ion trap mass spectrometry (GC-ITMS) working in MS/MS mode has become an interesting alternative technique to GC-HRMS for the analysis of PCDD/Fs and dl-PCBs. The aim of the present work is to demonstrate the ability of the gas chromatography coupled with ion-trap tandem mass spectrometry (GC-ITMS/MS) for the analysis of PCDD/Fs and dl-PCBs in food and feed samples. This work was performed on the framework of the European research project called DIFFERENCE (Dioxins in Food and Feed - Reference methods and New Certified Reference Materials) with the objective to validate the GC-ITMS/MS method as alternative to HRMS in order to reduce the cost of dioxin analysis. The results and conclusions of the evaluation study are presented here.

  6. Two-compartment, two-sample technique for accurate estimation of effective renal plasma flow: Theoretical development and comparison with other methods

    International Nuclear Information System (INIS)

    Lear, J.L.; Feyerabend, A.; Gregory, C.

    1989-01-01

    Discordance between effective renal plasma flow (ERPF) measurements from radionuclide techniques that use single versus multiple plasma samples was investigated. In particular, the authors determined whether effects of variations in distribution volume (Vd) of iodine-131 iodohippurate on measurement of ERPF could be ignored, an assumption implicit in the single-sample technique. The influence of Vd on ERPF was found to be significant, a factor indicating an important and previously unappreciated source of error in the single-sample technique. Therefore, a new two-compartment, two-plasma-sample technique was developed on the basis of the observations that while variations in Vd occur from patient to patient, the relationship between intravascular and extravascular components of Vd and the rate of iodohippurate exchange between the components are stable throughout a wide range of physiologic and pathologic conditions. The new technique was applied in a series of 30 studies in 19 patients. Results were compared with those achieved with the reference, single-sample, and slope-intercept techniques. The new two-compartment, two-sample technique yielded estimates of ERPF that more closely agreed with the reference multiple-sample method than either the single-sample or slope-intercept techniques

  7. SNP calling using genotype model selection on high-throughput sequencing data

    KAUST Repository

    You, Na

    2012-01-16

    Motivation: A review of the available single nucleotide polymorphism (SNP) calling procedures for Illumina high-throughput sequencing (HTS) platform data reveals that most rely mainly on base-calling and mapping qualities as sources of error when calling SNPs. Thus, errors not involved in base-calling or alignment, such as those in genomic sample preparation, are not accounted for.Results: A novel method of consensus and SNP calling, Genotype Model Selection (GeMS), is given which accounts for the errors that occur during the preparation of the genomic sample. Simulations and real data analyses indicate that GeMS has the best performance balance of sensitivity and positive predictive value among the tested SNP callers. © The Author 2012. Published by Oxford University Press. All rights reserved.

  8. Neutron activation analysis technique and X-ray fluorescence in bovine liver sample

    International Nuclear Information System (INIS)

    Maihara, V.A.; Favaro, D.I.T.; Vasconcellos, M.B.A.; Sato, I.M.; Salvador, V.L.

    2002-01-01

    Many analytical techniques have been used in food and diet analysis in order to determine a great number of nutritional elements, ranging from percentage to ng g -1 , with high sensitivity and accuracy. Instrumental Neutron activation Analysis (INAA) has been employed to certificate many trace elements in biological reference materials. More recently, the X-Ray Fluorescence (FRX-WD) has been also used to determine some essential elements in food samples. The INAA has been applied in nutrition studies in our laboratory at IPEN since the 80 s. For the development of analytical methodologies the use of the reference materials with the same characteristics of the sample analyzed is essential. Several Brazilian laboratories do not have conditions to use these materials due their high cost.In this paper preliminary results of commercial bovine liver sample analyses obtained by INAA and WD-XRF methods are presented. This sample was prepared to be a Brazilian candidate of reference material for a group of laboratories participating in a research project sponsored by FAPESP. The concentrations of some elements like Cl, K, Na, P, S and trace elements Br, Ca, Co, Cu, Fe, Mg, Mn, Mo, Rb, Se and Zn were determined by INAA and WD-XFR. For validation methodology of both techniques, NIST SRM 1577b Bovine Liver reference material was analyzed and the detection limits were calculated. The concentrations of elements determined by both analytical techniques were compared by using the Student's t-test and for Cl, Cu, Fe, K, Mg, Na, Rn and Zn the results do show no statistical difference for 95% significance level. (author)

  9. Improved mesh based photon sampling techniques for neutron activation analysis

    International Nuclear Information System (INIS)

    Relson, E.; Wilson, P. P. H.; Biondo, E. D.

    2013-01-01

    The design of fusion power systems requires analysis of neutron activation of large, complex volumes, and the resulting particles emitted from these volumes. Structured mesh-based discretization of these problems allows for improved modeling in these activation analysis problems. Finer discretization of these problems results in large computational costs, which drives the investigation of more efficient methods. Within an ad hoc subroutine of the Monte Carlo transport code MCNP, we implement sampling of voxels and photon energies for volumetric sources using the alias method. The alias method enables efficient sampling of a discrete probability distribution, and operates in 0(1) time, whereas the simpler direct discrete method requires 0(log(n)) time. By using the alias method, voxel sampling becomes a viable alternative to sampling space with the 0(1) approach of uniformly sampling the problem volume. Additionally, with voxel sampling it is straightforward to introduce biasing of volumetric sources, and we implement this biasing of voxels as an additional variance reduction technique that can be applied. We verify our implementation and compare the alias method, with and without biasing, to direct discrete sampling of voxels, and to uniform sampling. We study the behavior of source biasing in a second set of tests and find trends between improvements and source shape, material, and material density. Overall, however, the magnitude of improvements from source biasing appears to be limited. Future work will benefit from the implementation of efficient voxel sampling - particularly with conformal unstructured meshes where the uniform sampling approach cannot be applied. (authors)

  10. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis.

    Science.gov (United States)

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-05

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH 4 + strategy for ethylene and SO 2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO 2 from fruits. It was satisfied that trace ethylene and SO 2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO 2 during the entire LVCC sampling process were proved to be gas targets from real samples by SERS. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. SNP calling using genotype model selection on high-throughput sequencing data

    KAUST Repository

    You, Na; Murillo, Gabriel; Su, Xiaoquan; Zeng, Xiaowei; Xu, Jian; Ning, Kang; Zhang, ShouDong; Zhu, Jian-Kang; Cui, Xinping

    2012-01-01

    calling SNPs. Thus, errors not involved in base-calling or alignment, such as those in genomic sample preparation, are not accounted for.Results: A novel method of consensus and SNP calling, Genotype Model Selection (GeMS), is given which accounts

  12. Optical transmission testing based on asynchronous sampling techniques: images analysis containing chromatic dispersion using convolutional neural network

    Science.gov (United States)

    Mrozek, T.; Perlicki, K.; Tajmajer, T.; Wasilewski, P.

    2017-08-01

    The article presents an image analysis method, obtained from an asynchronous delay tap sampling (ADTS) technique, which is used for simultaneous monitoring of various impairments occurring in the physical layer of the optical network. The ADTS method enables the visualization of the optical signal in the form of characteristics (so called phase portraits) that change their shape under the influence of impairments such as chromatic dispersion, polarization mode dispersion and ASE noise. Using this method, a simulation model was built with OptSim 4.0. After the simulation study, data were obtained in the form of images that were further analyzed using the convolutional neural network algorithm. The main goal of the study was to train a convolutional neural network to recognize the selected impairment (distortion); then to test its accuracy and estimate the impairment for the selected set of test images. The input data consisted of processed binary images in the form of two-dimensional matrices, with the position of the pixel. This article focuses only on the analysis of images containing chromatic dispersion.

  13. Application of digital sampling techniques to particle identification in scintillation detectors

    International Nuclear Information System (INIS)

    Bardelli, L.; Bini, M.; Poggi, G.; Taccetti, N.

    2002-01-01

    In this paper, the use of a fast digitizing system for identification of fast charged particles with scintillation detectors is discussed. The three-layer phoswich detectors developed in the framework of the FIASCO experiment for the detection of light charged particles (LCP) and intermediate mass fragments (IMF) emitted in heavy-ion collisions at Fermi energies are briefly discussed. The standard analog electronics treatment of the signals for particle identification is illustrated. After a description of the digitizer designed to perform a fast digital sampling of the phoswich signals, the feasibility of particle identification on the sampled data is demonstrated. The results obtained with two different pulse shape discrimination analyses based on the digitally sampled data are compared with the standard analog signal treatment. The obtained results suggest, for the present application, the replacement of the analog methods with the digital sampling technique

  14. Uranium content measurement in drinking water samples using track etch technique

    International Nuclear Information System (INIS)

    Kumar, Mukesh; Kumar, Ajay; Singh, Surinder; Mahajan, R.K.; Walia, T.P.S.

    2003-01-01

    The concentration of uranium has been assessed in drinking water samples collected from different locations in Bathinda district, Punjab, India. The water samples are taken from hand pumps and tube wells. Uranium is determined using fission track technique. Uranium concentration in the water samples varies from 1.65±0.06 to 74.98±0.38 μg/l. These values are compared with safe limit values recommended for drinking water. Most of the water samples are found to have uranium concentration above the safe limit. Analysis of some heavy metals (Zn, Cd, Pb and Cu) in water is also done in order to see if some correlation exists between the concentration of uranium and these heavy metals. A weak positive correlation has been observed between the concentration of uranium and heavy metals of Pb, Cd and Cu

  15. Attempts to develop a new nuclear measurement technique of β-glucuronidase levels in biological samples

    International Nuclear Information System (INIS)

    Unak, T.; Avcibasi, U.; Yildirim, Y.; Cetinkaya, B.

    2003-01-01

    β-Glucuronidase is one of the most important hydrolytic enzymes in living systems and plays an essential role in the detoxification pathway of toxic materials incorporated into the metabolism. Some organs, especially liver and some tumour tissues, have high level of β-glucuronidase activity. As a result the enzymatic activity of some kind of tumour cells, the radiolabelled glucuronide conjugates of cytotoxic, as well as radiotoxic compounds have potentially very valuable diagnostic and therapeutic applications in cancer research. For this reason, a sensitive measurement of β-glucuronidase levels in normal and tumour tissues is a very important step for these kinds of applications. According to the classical measurement method of β-glucuronidase activity, in general, the quantity of phenolphthalein liberated from its glucuronide conjugate, i.e. phenolphthalein-glucuronide, by β-glucuronidase has been measured by use of the spectrophotometric technique. The lower detection limit of phenolphthalein by the spectrophotometric technique is about 1-3 mg. This means that the β-glucuronidase levels could not be detected in biological samples having lower levels of β-glucuronidase activity and therefore the applications of the spectrophotometric technique in cancer research are very seriously limited. Starting from this consideration, we recently attempted to develop a new nuclear technique to measure much lower concentrations of β-glucuronidase in biological samples. To improve the detection limit, phenolphthalein-glucuronide and also phenyl-N-glucuronide were radioiodinated with 131 I and their radioactivity was measured by use of the counting technique. Therefore, the quantity of phenolphthalein or aniline radioiodinated with 131 I and liberated by the deglucuronidation reactivity of β-glucuronidase was used in an attempt to measure levels lower than the spectrophotometric measurement technique. The results obtained clearly verified that 0.01 pg level of

  16. Attenuation of species abundance distributions by sampling

    Science.gov (United States)

    Shimadzu, Hideyasu; Darnell, Ross

    2015-01-01

    Quantifying biodiversity aspects such as species presence/ absence, richness and abundance is an important challenge to answer scientific and resource management questions. In practice, biodiversity can only be assessed from biological material taken by surveys, a difficult task given limited time and resources. A type of random sampling, or often called sub-sampling, is a commonly used technique to reduce the amount of time and effort for investigating large quantities of biological samples. However, it is not immediately clear how (sub-)sampling affects the estimate of biodiversity aspects from a quantitative perspective. This paper specifies the effect of (sub-)sampling as attenuation of the species abundance distribution (SAD), and articulates how the sampling bias is induced to the SAD by random sampling. The framework presented also reveals some confusion in previous theoretical studies. PMID:26064626

  17. Development of Large Sample Neutron Activation Technique for New Applications in Thailand

    International Nuclear Information System (INIS)

    Laoharojanaphand, S.; Tippayakul, C.; Wonglee, S.; Channuie, J.

    2018-01-01

    The development of the Large Sample Neutron Activation Analysis (LSNAA) in Thailand is presented in this paper. The technique had been firstly developed with rice sample as the test subject. The Thai Research Reactor-1/Modification 1 (TRR-1/M1) was used as the neutron source. The first step was to select and characterize an appropriate irradiation facility for the research. An out-core irradiation facility (A4 position) was first attempted. The results performed with the A4 facility were then used as guides for the subsequent experiments with the thermal column facility. The characterization of the thermal column was performed with Cu-wire to determine spatial distribution without and with rice sample. The flux depression without rice sample was observed to be less than 30% while the flux depression with rice sample increased to within 60%. The flux monitors internal to the rice sample were used to determine average flux over the rice sample. The gamma selfshielding effect during gamma measurement was corrected using the Monte Carlo simulation. The ratio between the efficiencies of the volume source and the point source for each energy point was calculated by the MCNPX code. The research team adopted the k0-NAA methodology to calculate the element concentration in the research. The k0-NAA program which developed by IAEA was set up to simulate the conditions of the irradiation and measurement facilities used in this research. The element concentrations in the bulk rice sample were then calculated taking into account the flux depression and gamma efficiency corrections. At the moment, the results still show large discrepancies with the reference values. However, more research on the validation will be performed to identify sources of errors. Moreover, this LS-NAA technique was introduced for the activation analysis of the IAEA archaeological mock-up. The results are provided in this report. (author)

  18. Investigating CALL in the Classroom: Situational Variables to Consider

    Directory of Open Access Journals (Sweden)

    Darlene Liutkus

    2012-01-01

    Full Text Available A new paradigm in second language pedagogy has Computer Assisted Language Learning (CALL playing a significant role. Much of the literature to-date claims that CALL can have a positive impact on students’ second language acquisition (SLA. Mixed method of research produces data to investigate if CALL positively affects student language proficiency, motivation and autonomy. Classroom observation of participants in their natural environment is a qualitative technique used but has situational variables that could skew results if not structured. A questionnaire is a quantitative tool that can offer insight regarding participants’ perception of performance but can contradict what the researcher has observed. This paper will take an in-depth look at variables such as: instructor’s pedagogical application; blending CALL into the curriculum; types of CALL implemented; feedback received and their implications for design of the data collection tools

  19. System health monitoring using multiple-model adaptive estimation techniques

    Science.gov (United States)

    Sifford, Stanley Ryan

    Monitoring system health for fault detection and diagnosis by tracking system parameters concurrently with state estimates is approached using a new multiple-model adaptive estimation (MMAE) method. This novel method is called GRid-based Adaptive Parameter Estimation (GRAPE). GRAPE expands existing MMAE methods by using new techniques to sample the parameter space. GRAPE expands on MMAE with the hypothesis that sample models can be applied and resampled without relying on a predefined set of models. GRAPE is initially implemented in a linear framework using Kalman filter models. A more generalized GRAPE formulation is presented using extended Kalman filter (EKF) models to represent nonlinear systems. GRAPE can handle both time invariant and time varying systems as it is designed to track parameter changes. Two techniques are presented to generate parameter samples for the parallel filter models. The first approach is called selected grid-based stratification (SGBS). SGBS divides the parameter space into equally spaced strata. The second approach uses Latin Hypercube Sampling (LHS) to determine the parameter locations and minimize the total number of required models. LHS is particularly useful when the parameter dimensions grow. Adding more parameters does not require the model count to increase for LHS. Each resample is independent of the prior sample set other than the location of the parameter estimate. SGBS and LHS can be used for both the initial sample and subsequent resamples. Furthermore, resamples are not required to use the same technique. Both techniques are demonstrated for both linear and nonlinear frameworks. The GRAPE framework further formalizes the parameter tracking process through a general approach for nonlinear systems. These additional methods allow GRAPE to either narrow the focus to converged values within a parameter range or expand the range in the appropriate direction to track the parameters outside the current parameter range boundary

  20. Direct sampling technique of bees on Vriesea philippocoburgii (Bromeliaceae, Tillandsioideae flowers

    Directory of Open Access Journals (Sweden)

    Afonso Inácio Orth

    2004-11-01

    Full Text Available In our study on Vriesea philippocoburgii Wawra pollination, due to the small proportion of flowers in anthesis on a single day and the damage caused to inflorescences when netting directly on flowers, we used the direct sampling technique (DST of bees on flowers. This technique was applied to 40 flowering plants and resulted in the capture of 160 specimens, belonging to nine genera of Apoidea and separated into 19 morph species. As DST maintains the integrity of flowers for later Bees’ visits, it can enhance the survey’s performance, constituting an alternative methodology for the collection of bees visiting flowering plants.

  1. Identification of unknown sample using NAA, EDXRF, XRD techniques

    International Nuclear Information System (INIS)

    Dalvi, Aditi A.; Swain, K.K.; Chavan, Trupti; Remya Devi, P.S.; Wagh, D.N.; Verma, R.

    2015-01-01

    Analytical Chemistry Division (ACD), Bhabha Atomic Research Centre (BARC) receives samples from law enforcement agencies such as Directorate of Revenue Intelligence, Customs for analysis. Five unknown grey powdered samples were received for identification and were suspected to be Iridium (Ir). Identification of unknown sample is always a challenging task and suitable analytical techniques have to be judiciously utilized for arriving at the conclusion. Qualitative analysis was carried out using Jordan Valley, EX-3600 M Energy dispersive X-ray fluorescence (EDXRF) spectrometer at ACD, BARC. A SLP series LEO Si (Li) detector (active area: 30 mm 2 ; thickness: 3.5 mm; resolution: 140 eV at 5.9 keV of Mn K X-ray) was used during the measurement and only characteristic X-rays of Ir (Lα: 9.17 keV and Lβ: 10.70 keV) was seen in the X-ray spectrum. X-ray diffraction (XRD) measurement results indicated that the Ir was in the form of metal. To confirm the XRD data, neutron activation analysis (NAA) was carried out by irradiating samples and elemental standards (as comparator) in graphite reflector position of Advanced Heavy Water Reactor Critical Facility (AHWR CF) reactor, BARC, Mumbai. After suitable decay period, gamma activity measurements were carried out using 45% HPGe detector coupled to 8 k multi channel analyzer. Characteristic gamma line at 328.4 keV of the activation product 194 Ir was used for quantification of iridium and relative method of NAA was used for concentration calculations. NAA results confirmed that all the samples were Iridium metal. (author)

  2. Development of SYVAC sampling techniques

    International Nuclear Information System (INIS)

    Prust, J.O.; Dalrymple, G.J.

    1985-04-01

    This report describes the requirements of a sampling scheme for use with the SYVAC radiological assessment model. The constraints on the number of samples that may be taken is considered. The conclusions from earlier studies using the deterministic generator sampling scheme are summarised. The method of Importance Sampling and a High Dose algorithm, which are designed to preferentially sample in the high dose region of the parameter space, are reviewed in the light of experience gained from earlier studies and the requirements of a site assessment and sensitivity analyses. In addition the use of an alternative numerical integration method for estimating risk is discussed. It is recommended that the method of Importance Sampling is developed and tested for use with SYVAC. An alternative numerical integration method is not recommended for investigation at this stage but should be the subject of future work. (author)

  3. SNPMClust: Bivariate Gaussian Genotype Clustering and Calling for Illumina Microarrays

    Directory of Open Access Journals (Sweden)

    Stephen W. Erickson

    2016-07-01

    Full Text Available SNPMClust is an R package for genotype clustering and calling with Illumina microarrays. It was originally developed for studies using the GoldenGate custom genotyping platform but can be used with other Illumina platforms, including Infinium BeadChip. The algorithm first rescales the fluorescent signal intensity data, adds empirically derived pseudo-data to minor allele genotype clusters, then uses the package mclust for bivariate Gaussian model fitting. We compared the accuracy and sensitivity of SNPMClust to that of GenCall, Illumina's proprietary algorithm, on a data set of 94 whole-genome amplified buccal (cheek swab DNA samples. These samples were genotyped on a custom panel which included 1064 SNPs for which the true genotype was known with high confidence. SNPMClust produced uniformly lower false call rates over a wide range of overall call rates.

  4. Nonactivation interaction techniques in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.

    1986-01-01

    Nonactivation interaction analytical methods are based on the interaction processes of nuclear and X-ray radiation with a sample, leading to their absorption and backscattering, to the ionization of gases or excitation of fluorescent X-ray by radiation, but not to the activation of determined elements. From the point of view of environmental analysis, the most useful nonactivation interaction techniques are X-ray fluorescence by photon or charged particle excitation, ionization of gases by nuclear radiation, elastic scattering of charged particles and backscattering of beta radiation. The significant advantage of these methods is that they are nondestructive. (author)

  5. Thorium content of a mineral ore from Morro do Ferro by fission track technique

    International Nuclear Information System (INIS)

    Oliveira, C.A.N. de.

    1980-10-01

    The feasibility to determine thorium concentrations by fission track technique in samples of mineral ore has been demonstrated. The literature registers only the application of the fission track technique to mineral ore in the case where the fissionable element is uranium. The technique was applied to determine the thorium concentration of an ore sample from Morro do Ferro, taking advantage of the high thorium to uranium ratio in that mineral. The sample analysed presented a thorium concentration of 2467 +- 400 mg Th/Kg ore. The so called wet method was adopted by using the Bayer made Makrofol KG 10μm thick, as the detector foil, immersed in the thorium solution. The technique is also useful to determine thorium concentrations in environmental samples because of the following aspects: high sensitivity; fast chemical separation of interfering elements; low cost; and operational simplicity. (Author) [pt

  6. SNP calling, genotype calling, and sample allele frequency estimation from new-generation sequencing data

    DEFF Research Database (Denmark)

    Nielsen, Rasmus; Korneliussen, Thorfinn Sand; Albrechtsen, Anders

    2012-01-01

    We present a statistical framework for estimation and application of sample allele frequency spectra from New-Generation Sequencing (NGS) data. In this method, we first estimate the allele frequency spectrum using maximum likelihood. In contrast to previous methods, the likelihood function is cal...... be extended to various other cases including cases with deviations from Hardy-Weinberg equilibrium. We evaluate the statistical properties of the methods using simulations and by application to a real data set....

  7. Comparison of Techniques for Sampling Adult Necrophilous Insects From Pig Carcasses.

    Science.gov (United States)

    Cruise, Angela; Hatano, Eduardo; Watson, David W; Schal, Coby

    2018-02-06

    Studies of the pre-colonization interval and mechanisms driving necrophilous insect ecological succession depend on effective sampling of adult insects and knowledge of their diel and successional activity patterns. The number of insects trapped, their diversity, and diel periodicity were compared with four sampling methods on neonate pigs. Sampling method, time of day and decomposition age of the pigs significantly affected the number of insects sampled from pigs. We also found significant interactions of sampling method and decomposition day, time of sampling and decomposition day. No single method was superior to the other methods during all three decomposition days. Sampling times after noon yielded the largest samples during the first 2 d of decomposition. On day 3 of decomposition however, all sampling times were equally effective. Therefore, to maximize insect collections from neonate pigs, the method used to sample must vary by decomposition day. The suction trap collected the most species-rich samples, but sticky trap samples were the most diverse, when both species richness and evenness were factored into a Shannon diversity index. Repeated sampling during the noon to 18:00 hours period was most effective to obtain the maximum diversity of trapped insects. The integration of multiple sampling techniques would most effectively sample the necrophilous insect community. However, because all four tested methods were deficient at sampling beetle species, future work should focus on optimizing the most promising methods, alone or in combinations, and incorporate hand-collections of beetles. © The Author(s) 2018. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Multi-element analysis of lubricant oil by WDXRF technique using thin-film sample preparation

    International Nuclear Information System (INIS)

    Scapin, M. A.; Salvador, V. L. R.; Lopes, C. D.; Sato, I. M.

    2006-01-01

    The quantitative analysis of the chemical elements in matrices like oils or gels represents a challenge for the analytical chemists. The classics methods or instrumental techniques such as atomic absorption spectrometry (AAS) and plasma optical emission spectrometry (ICP-OES) need chemical treatments, mainly sample dissolution and degradation processes. X-ray fluorescence technique allows a direct and multi-element analysis without previous sample treatments. In this work, a sensible method for the determination of elements Mg, Al, Si, P, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Mo, Ag, Sn, Ba and Pb in lubricating oil is presented. The x-ray fluorescence (WDXRF) technique using linear regression method and thin film sample preparation was used. The validation of the methodology (repeatability and accuracy) was obtained by the analysis of the standard reference materials SRM Alpha AESAR lot 703527D, applying the Chauvenet, Cochrane, ANOVA and Z-score statistical tests. The method presents a relative standard deviation lower than 10% for all the elements, except for Pb determination (RSD Pb 15%). The Z-score values for all the elements were in the range -2 < Z < 2, indicating a very good accuracy.(Full text)

  9. Human mixed lymphocyte cultures. Evaluation of microculture technique utilizing the multiple automated sample harvester (MASH)

    Science.gov (United States)

    Thurman, G. B.; Strong, D. M.; Ahmed, A.; Green, S. S.; Sell, K. W.; Hartzman, R. J.; Bach, F. H.

    1973-01-01

    Use of lymphocyte cultures for in vitro studies such as pretransplant histocompatibility testing has established the need for standardization of this technique. A microculture technique has been developed that has facilitated the culturing of lymphocytes and increased the quantity of cultures feasible, while lowering the variation between replicate samples. Cultures were prepared for determination of tritiated thymidine incorporation using a Multiple Automated Sample Harvester (MASH). Using this system, the parameters that influence the in vitro responsiveness of human lymphocytes to allogeneic lymphocytes have been investigated. PMID:4271568

  10. [Influence of Natural Dissolved Organic Matter on the Passive Sampling Technique and its Application].

    Science.gov (United States)

    Yu, Shang-yun; Zhou, Yan-mei

    2015-08-01

    This paper studied the effects of different concentrations of natural dissolved organic matter (DOM) on the passive sampling technique. The results showed that the presence of DOM affected the organic pollutant adsorption ability of the membrane. For lgK(OW), 3-5, DOM had less impact on the adsorption of organic matter by the membrane; for lgK(OW), > 5.5, DOM significantly increased the adsorption capacity of the membrane. Meanwhile, LDPE passive sampling technique was applied to monitor PAHs and PAEs in pore water of three surface sediments in Taizi River. All of the target pollutants were detected in varying degrees at each sampling point. Finally, the quotient method was used to assess the ecological risks of PAHs and PAEs. The results showed that fluoranthene exceeded the reference value of the aquatic ecosystem, meaning there was a big ecological risk.

  11. Detecting reactive islands using Lagrangian descriptors and the relevance to transition path sampling.

    Science.gov (United States)

    Patra, Sarbani; Keshavamurthy, Srihari

    2018-02-14

    It has been known for sometime now that isomerization reactions, classically, are mediated by phase space structures called reactive islands (RI). RIs provide one possible route to correct for the nonstatistical effects in the reaction dynamics. In this work, we map out the reactive islands for the two dimensional Müller-Brown model potential and show that the reactive islands are intimately linked to the issue of rare event sampling. In particular, we establish the sensitivity of the so called committor probabilities, useful quantities in the transition path sampling technique, to the hierarchical RI structures. Mapping out the RI structure for high dimensional systems, however, is a challenging task. Here, we show that the technique of Lagrangian descriptors is able to effectively identify the RI hierarchy in the model system. Based on our results, we suggest that the Lagrangian descriptors can be useful for detecting RIs in high dimensional systems.

  12. Design and building of a homemade sample changer for automation of the irradiation in neutron activation analysis technique; Diseno y construccion de un prototipo de intercambiador para la automatizacion de la tecnica de analisis por activacion neutronica

    Energy Technology Data Exchange (ETDEWEB)

    Gago, Javier; Hernandez, Yuri; Baltuano, Oscar; Bedregal, Patricia [Direccion de Investigacion y Desarrollo, Instituto Peruano de Energia Nuclear, Lima (Peru); Lopez, Yon [Universidad Nacional de Ingenieria, Lima (Peru); Urquizo, Rafael [Universidad Tecnologica del Peru, Lima (Peru)

    2014-07-01

    Because the RP-10 research reactor operates during weekends, it was necessary to design and build a sample changer for irradiation as part of the automation process of neutron activation analysis technique. The device is formed by an aluminum turntable disk which can accommodate 19 polyethylene capsules, containing samples to be sent using the pneumatic transfer system from the laboratory to the irradiation position. The system is operate by a control switchboard to send and return capsules in a variable preset time and by two different ways, allowing the determination of short, medium and long lived radionuclides. Also another mechanism is designed called 'exchange valve' for changing travel paths (pipelines) allowing the irradiated samples to be stored for a longer time in the reactor hall. The system design has allowed complete automation of this technique, enabling the irradiation of samples without the presence of an analyst. The design, construction and operation of the device is described and presented in this article. (authors).

  13. Optimal sampling strategy for data mining

    International Nuclear Information System (INIS)

    Ghaffar, A.; Shahbaz, M.; Mahmood, W.

    2013-01-01

    Latest technology like Internet, corporate intranets, data warehouses, ERP's, satellites, digital sensors, embedded systems, mobiles networks all are generating such a massive amount of data that it is getting very difficult to analyze and understand all these data, even using data mining tools. Huge datasets are becoming a difficult challenge for classification algorithms. With increasing amounts of data, data mining algorithms are getting slower and analysis is getting less interactive. Sampling can be a solution. Using a fraction of computing resources, Sampling can often provide same level of accuracy. The process of sampling requires much care because there are many factors involved in the determination of correct sample size. The approach proposed in this paper tries to find a solution to this problem. Based on a statistical formula, after setting some parameters, it returns a sample size called s ufficient sample size , which is then selected through probability sampling. Results indicate the usefulness of this technique in coping with the problem of huge datasets. (author)

  14. Heating and thermal control of brazing technique to break contamination path for potential Mars sample return

    Science.gov (United States)

    Bao, Xiaoqi; Badescu, Mircea; Sherrit, Stewart; Bar-Cohen, Yoseph; Campos, Sergio

    2017-04-01

    The potential return of Mars sample material is of great interest to the planetary science community, as it would enable extensive analysis of samples with highly sensitive laboratory instruments. It is important to make sure such a mission concept would not bring any living microbes, which may possibly exist on Mars, back to Earth's environment. In order to ensure the isolation of Mars microbes from Earth's Atmosphere, a brazing sealing and sterilizing technique was proposed to break the Mars-to-Earth contamination path. Effectively, heating the brazing zone in high vacuum space and controlling the sample temperature for integrity are key challenges to the implementation of this technique. The break-thechain procedures for container configurations, which are being considered, were simulated by multi-physics finite element models. Different heating methods including induction and resistive/radiation were evaluated. The temperature profiles of Martian samples in a proposed container structure were predicted. The results show that the sealing and sterilizing process can be controlled such that the samples temperature is maintained below the level that may cause damage, and that the brazing technique is a feasible approach to breaking the contamination path.

  15. Calling and Life Satisfaction: It's Not about Having It, It's about Living It

    Science.gov (United States)

    Duffy, Ryan D.; Allan, Blake A.; Autin, Kelsey L.; Bott, Elizabeth M.

    2013-01-01

    The present study examined the relation of career calling to life satisfaction among a diverse sample of 553 working adults, with a specific focus on the distinction between perceiving a calling (sensing a calling to a career) and living a calling (actualizing one's calling in one's current career). As hypothesized, the relation of perceiving a…

  16. Texture investigation in aluminium and iron - silicon samples by neutron diffraction technique

    International Nuclear Information System (INIS)

    Pugliese, R.; Yamasaki, J.M.

    1988-09-01

    By means of the neutron diffraction technique the texture of 5% and 98% rolled-aluminium and of iron-silicon steel used in the core of electric transformers, have been determined. The measurements were performed by using a neutron diffractometer installed at the IEA-R1 Nuclear Research Reactor, in the Beam-Hole n 0 . 6. To avoid corrections such as neutron absorption and sample luminosity the geometric form of the samples were approximated to spheric or octagonal prism, and its dimensions do not exceed that of the neutron beam. The texture of the samples were analysed with the help of a computer programme that analyses the intensity of the diffracted neutron beam and plot the pole figures. (author) [pt

  17. The particle analysis based on FT-TIMS technique for swipe sample under the frame of nuclear safeguard

    International Nuclear Information System (INIS)

    Yang Tianli; Liu Xuemei; Liu Zhao; Tang Lei; Long Kaiming

    2008-06-01

    Under the frame of nuclear safeguard, the particles analysis for swipe sample is an advance mean to detect the undeclared uranium enriched facilities and undeclared uranium enriched activity. The technique of particle analysis based on fission track-thermal ionization mass spectrometry (FT-TIMS) for swipe sample have been built. The reliability and the experimental background for selecting particles consisting of uranium from swipe sample by FT method have been verified. In addition, the utilization coefficient of particles on the surface of swipe sample have also been tested. These works have provided the technique support for application in the area of nuclear verification. (authors)

  18. Addressee Errors in ATC Communications: The Call Sign Problem

    Science.gov (United States)

    Monan, W. P.

    1983-01-01

    Communication errors involving aircraft call signs were portrayed in reports of 462 hazardous incidents voluntarily submitted to the ASRS during an approximate four-year period. These errors resulted in confusion, disorder, and uncoordinated traffic conditions and produced the following types of operational anomalies: altitude deviations, wrong-way headings, aborted takeoffs, go arounds, runway incursions, missed crossing altitude restrictions, descents toward high terrain, and traffic conflicts in flight and on the ground. Analysis of the report set resulted in identification of five categories of errors involving call signs: (1) faulty radio usage techniques, (2) call sign loss or smearing due to frequency congestion, (3) confusion resulting from similar sounding call signs, (4) airmen misses of call signs leading to failures to acknowledge or readback, and (5) controller failures regarding confirmation of acknowledgements or readbacks. These error categories are described in detail and several associated hazard mitigating measures that might be aken are considered.

  19. Refinement of NMR structures using implicit solvent and advanced sampling techniques.

    Science.gov (United States)

    Chen, Jianhan; Im, Wonpil; Brooks, Charles L

    2004-12-15

    NMR biomolecular structure calculations exploit simulated annealing methods for conformational sampling and require a relatively high level of redundancy in the experimental restraints to determine quality three-dimensional structures. Recent advances in generalized Born (GB) implicit solvent models should make it possible to combine information from both experimental measurements and accurate empirical force fields to improve the quality of NMR-derived structures. In this paper, we study the influence of implicit solvent on the refinement of protein NMR structures and identify an optimal protocol of utilizing these improved force fields. To do so, we carry out structure refinement experiments for model proteins with published NMR structures using full NMR restraints and subsets of them. We also investigate the application of advanced sampling techniques to NMR structure refinement. Similar to the observations of Xia et al. (J.Biomol. NMR 2002, 22, 317-331), we find that the impact of implicit solvent is rather small when there is a sufficient number of experimental restraints (such as in the final stage of NMR structure determination), whether implicit solvent is used throughout the calculation or only in the final refinement step. The application of advanced sampling techniques also seems to have minimal impact in this case. However, when the experimental data are limited, we demonstrate that refinement with implicit solvent can substantially improve the quality of the structures. In particular, when combined with an advanced sampling technique, the replica exchange (REX) method, near-native structures can be rapidly moved toward the native basin. The REX method provides both enhanced sampling and automatic selection of the most native-like (lowest energy) structures. An optimal protocol based on our studies first generates an ensemble of initial structures that maximally satisfy the available experimental data with conventional NMR software using a simplified

  20. The experience sampling method: Investigating students' affective experience

    Science.gov (United States)

    Nissen, Jayson M.; Stetzer, MacKenzie R.; Shemwell, Jonathan T.

    2013-01-01

    Improving non-cognitive outcomes such as attitudes, efficacy, and persistence in physics courses is an important goal of physics education. This investigation implemented an in-the-moment surveying technique called the Experience Sampling Method (ESM) [1] to measure students' affective experience in physics. Measurements included: self-efficacy, cognitive efficiency, activation, intrinsic motivation, and affect. Data are presented that show contrasts in students' experiences (e.g., in physics vs. non-physics courses).

  1. Dosimetric characterization of BeO samples in alpha, beta and X radiation beams using luminescent techniques

    International Nuclear Information System (INIS)

    Groppo, Daniela Piai

    2013-01-01

    In the medical field, the ionizing radiation is used both for therapeutic and diagnostic purposes, in a wide range of radiation doses. In order to ensure that the objective is achieved in practice, detailed studies of detectors and devices in different types of radiations beams are necessary. In this work a dosimetric characterization of BeO samples was performed using the techniques of thermoluminescence (TL) and optically stimulated luminescence (OSL) by a comparison of their response for alpha, beta and X radiations and the establishment of an appropriated system for use in monitoring of these radiations beams. The main results are: the high sensitivity to beta radiation for both techniques, good reproducibility of TL and OSL response (coefficients of variation lower than 5%), maximum energy dependence of the X radiation of 28% for the TL technique, and only 7% for the OSL technique, within the studied energy range. The dosimetric characteristics obtained in this work show the possibility of applying BeO samples to dosimetry of alpha, beta and X radiations, considering the studied dose ranges, using the TL and OSL techniques. From the results obtained, the samples of BeO showed their potential use for beam dosimetry in diagnostic radiology and radiotherapy. (author)

  2. Control-flow analysis of function calls and returns by abstract interpretation

    DEFF Research Database (Denmark)

    Midtgaard, Jan; Jensen, Thomas P.

    2012-01-01

    Abstract interpretation techniques are used to derive a control-flow analysis for a simple higher-order functional language. The analysis approximates the interprocedural control-flow of both function calls and returns in the presence of first-class functions and tail-call optimization. In additi...... a rational reconstruction of a constraint-based CFA from abstract interpretation principles....

  3. Pan-cancer analysis reveals technical artifacts in TCGA germline variant calls.

    Science.gov (United States)

    Buckley, Alexandra R; Standish, Kristopher A; Bhutani, Kunal; Ideker, Trey; Lasken, Roger S; Carter, Hannah; Harismendy, Olivier; Schork, Nicholas J

    2017-06-12

    Cancer research to date has largely focused on somatically acquired genetic aberrations. In contrast, the degree to which germline, or inherited, variation contributes to tumorigenesis remains unclear, possibly due to a lack of accessible germline variant data. Here we called germline variants on 9618 cases from The Cancer Genome Atlas (TCGA) database representing 31 cancer types. We identified batch effects affecting loss of function (LOF) variant calls that can be traced back to differences in the way the sequence data were generated both within and across cancer types. Overall, LOF indel calls were more sensitive to technical artifacts than LOF Single Nucleotide Variant (SNV) calls. In particular, whole genome amplification of DNA prior to sequencing led to an artificially increased burden of LOF indel calls, which confounded association analyses relating germline variants to tumor type despite stringent indel filtering strategies. The samples affected by these technical artifacts include all acute myeloid leukemia and practically all ovarian cancer samples. We demonstrate how technical artifacts induced by whole genome amplification of DNA can lead to false positive germline-tumor type associations and suggest TCGA whole genome amplified samples be used with caution. This study draws attention to the need to be sensitive to problems associated with a lack of uniformity in data generation in TCGA data.

  4. Long-term monitoring of the Danube river-Sampling techniques, radionuclide metrology and radioecological assessment

    International Nuclear Information System (INIS)

    Maringer, F.J.; Gruber, V.; Hrachowitz, M.; Baumgartner, A.; Weilner, S.; Seidel, C.

    2009-01-01

    Sampling techniques and radiometric methods, developed and applied in a comprehensive radioecological study of the Danube River are presented. Results and radiometric data of sediment samples, collected by sediment traps in Austria and additionally by grab sampling in the Danube during research cruises between Germany and the delta (Black sea) are shown and discussed. Goal of the investigation is the protection of public and environment, especially the sustainable use and conservation of human freshwater resources against harmful radioactive exposure.

  5. Separation of arsenic species by capillary electrophoresis with sample-stacking techniques

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zu Liang; Naidu, Ravendra [Adelaide Laboratory, CSIRO Land and Water, PMB2, 5064, Glen Osmond, SA (Australia); Lin, Jin-Ming [Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, 100085, Beijing (China)

    2003-03-01

    A simple capillary zone electrophoresis procedure was developed for the separation of arsenic species (AsO{sub 2}{sup 2-}, AsO{sub 4}{sup 2-}, and dimethylarsinic acid, DMA). Both counter-electroosmotic and co-electroosmotic (EOF) modes were investigated for the separation of arsenic species with direct UV detection at 185 nm using 20 mmol L{sup -1} sodium phosphate as the electrolyte. The separation selectivity mainly depends on the separation modes and electrolyte pH. Inorganic anions (Cl{sup -}, NO{sub 2}{sup -}, NO{sub 3}{sup -} and SO{sub 4}{sup 2-}) presented in real samples did not interfere with arsenic speciation in either separation mode. To improve the detection limits, sample-stacking techniques, including large-volume sample stacking (LVSS) and field-amplified sample injection (FASI), were investigated for the preconcentration of As species in co-CZE mode. Less than 1 {mu}mol L{sup -1} of detection limits for As species were achieved using FASI. The proposed method was demonstrated for the separation and detection of As species in water. (orig.)

  6. Decomposition and (importance) sampling techniques for multi-stage stochastic linear programs

    Energy Technology Data Exchange (ETDEWEB)

    Infanger, G.

    1993-11-01

    The difficulty of solving large-scale multi-stage stochastic linear programs arises from the sheer number of scenarios associated with numerous stochastic parameters. The number of scenarios grows exponentially with the number of stages and problems get easily out of hand even for very moderate numbers of stochastic parameters per stage. Our method combines dual (Benders) decomposition with Monte Carlo sampling techniques. We employ importance sampling to efficiently obtain accurate estimates of both expected future costs and gradients and right-hand sides of cuts. The method enables us to solve practical large-scale problems with many stages and numerous stochastic parameters per stage. We discuss the theory of sharing and adjusting cuts between different scenarios in a stage. We derive probabilistic lower and upper bounds, where we use importance path sampling for the upper bound estimation. Initial numerical results turned out to be promising.

  7. Monitoring of persistent organic pollutants in seawater of the Pearl River Estuary with rapid on-site active SPME sampling technique

    International Nuclear Information System (INIS)

    Huang, Siming; He, Shuming; Xu, Hao; Wu, Peiyan; Jiang, Ruifen; Zhu, Fang; Luan, Tiangang; Ouyang, Gangfeng

    2015-01-01

    An on-site active solid-phase microextraction (SPME) sampling technique coupled with gas chromatography-mass spectrometry (GC–MS) for sampling and monitoring 16 polycyclic aromatic hydrocarbons (PAHs) and 8 organochlorine pesticides (OCPs) in seawater was developed. Laboratory experiments demonstrated that the sampling-rate calibration method was practical and could be used for the quantification of on-site sampling. The proposed method was employed for field tests which covered large amounts of water samples in the Pearl River Estuary in rainy and dry seasons. The on-site SPME sampling method can avoid the contamination of sample, the losses of analytes during sample transportation, as well as the usage of solvent and time-consuming sample preparation process. Results indicated that the technique with the designed device can address the requirement of modern environment water analysis. In addition, the sources, bioaccumulation and potential risk to human of the PAHs and OCPs in seawater of the Pearl River Estuary were discussed. - Highlights: • SPME on-site active sampling technique was developed and validated. • The technique was employed for field tests in the Pearl River Estuary. • 16 PAHs and 8 OCPs in the seawater of Pearl River Estuary were monitored. • The potential risk of the PAHs and OCPs in Pearl River Estuary were discussed. - An on-site active SPME sampling technique was developed and successfully applied for sampling and monitoring 16 PAHs and 8 OCPs in the Pearl River Estuary

  8. Prompt Gamma Activation Analysis (PGAA): Technique of choice for nondestructive bulk analysis of returned comet samples

    International Nuclear Information System (INIS)

    Lindstrom, D.J.; Lindstrom, R.M.

    1989-01-01

    Prompt gamma activation analysis (PGAA) is a well-developed analytical technique. The technique involves irradiation of samples in an external neutron beam from a nuclear reactor, with simultaneous counting of gamma rays produced in the sample by neutron capture. Capture of neutrons leads to excited nuclei which decay immediately with the emission of energetic gamma rays to the ground state. PGAA has several advantages over other techniques for the analysis of cometary materials: (1) It is nondestructive; (2) It can be used to determine abundances of a wide variety of elements, including most major and minor elements (Na, Mg, Al, Si, P, K, Ca, Ti, Cr, Mn, Fe, Co, Ni), volatiles (H, C, N, F, Cl, S), and some trace elements (those with high neutron capture cross sections, including B, Cd, Nd, Sm, and Gd); and (3) It is a true bulk analysis technique. Recent developments should improve the technique's sensitivity and accuracy considerably

  9. Telephone calls by individuals with cancer.

    Science.gov (United States)

    Flannery, Marie; McAndrews, Leanne; Stein, Karen F

    2013-09-01

    To describe symptom type and reporting patterns found in spontaneously initiated telephone calls placed to an ambulatory cancer center practice. Retrospective, descriptive. Adult hematology oncology cancer center. 563 individuals with a wide range of oncology diagnoses who initiated 1,229 telephone calls to report symptoms. Raw data were extracted from telephone forms using a data collection sheet with 23 variables obtained for each phone call, using pre-established coding criteria. A literature-based, investigator-developed instrument was used for the coding criteria and selection of which variables to extract. Symptom reporting, telephone calls, pain, and symptoms. A total of 2,378 symptoms were reported by telephone during the four months. At least 10% of the sample reported pain (38%), fatigue (16%), nausea (16%), swelling (12%), diarrhea (12%), dyspnea (10%), and anorexia (10%). The modal response was to call only one time and to report only one symptom (55%). Pain emerged as the symptom that most often prompted an individual to pick up the telephone and call. Although variation was seen in symptom reporting, an interesting pattern emerged with an individual reporting on a solitary symptom in a single telephone call. The emergence of pain as the primary symptom reported by telephone prompted educational efforts for both in-person clinic visit management of pain and prioritizing nursing education and protocol management of pain reported by telephone. Report of symptoms by telephone can provide nurses unique insight into patient-centered needs. Although pain has been an important focus of education and research for decades, it remains a priority for individuals with cancer. A wide range in symptom reporting by telephone was evident.

  10. Experimental study of laser ablation as sample introduction technique for inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Van Winckel, S.

    2001-01-01

    The contribution consists of an abstract of a PhD thesis. In the PhD study, several complementary applications of laser-ablation were investigated in order to characterise experimentally laser ablation (LA) as a sample introduction technique for ICP-MS. Three applications of LA as a sample introduction technique are discussed: (1) the microchemical analysis of the patina of weathered marble; (2) the possibility to measure isotope ratios (in particular Pb isotope ratios in archaeological bronze artefacts); and (3) the determination of Si in Al as part of a dosimetric study of the BR2 reactor vessel

  11. Electropyroelectric technique for measurement of the thermal effusivity of liquids

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, R; Moreno, I; Araujo, C [Facultad de Fisica, Universidad Autonoma de Zacatecas, Calz. Solidaridad Esquina Paseo de la Bufa s/n, C. P. 98060, Zacatecas, Zac. (Mexico); Marin, E, E-mail: emarin63@yahoo.e, E-mail: emarinm@ipn.m [Centro de Investigacion en Ciencia Aplicada y TecnologIa Avanzada, Instituto Politecnico Nacional, LegarIa 694, Colonia Irrigacion, C. P. 11500, Mexico D. F. (Mexico)

    2010-06-09

    The photopyroelectric method has been recognized as a reliable and useful tool for the measurement of the thermal properties of condensed matter samples. Usually the photothermal signal is generated using intensity modulated light beams, whose amplitudes are difficult to maintain stable. In this paper we describe a variant of this technique that uses amplitude modulated electrical current as excitation source, via Joule heating of the metal contact on one side of the pyroelectric sensor. The possibilities of this method, called by us the electropyroelectric technique, for thermal effusivity measurements of liquid samples are shown using test samples of distilled water, ethanol and glycerine. The results obtained for this parameter agree well with the values reported in the literature. Our measurement uncertainties are about 3%, a fact that opens several possible applications.

  12. Electropyroelectric technique for measurement of the thermal effusivity of liquids

    International Nuclear Information System (INIS)

    Ivanov, R; Moreno, I; Araujo, C; Marin, E

    2010-01-01

    The photopyroelectric method has been recognized as a reliable and useful tool for the measurement of the thermal properties of condensed matter samples. Usually the photothermal signal is generated using intensity modulated light beams, whose amplitudes are difficult to maintain stable. In this paper we describe a variant of this technique that uses amplitude modulated electrical current as excitation source, via Joule heating of the metal contact on one side of the pyroelectric sensor. The possibilities of this method, called by us the electropyroelectric technique, for thermal effusivity measurements of liquid samples are shown using test samples of distilled water, ethanol and glycerine. The results obtained for this parameter agree well with the values reported in the literature. Our measurement uncertainties are about 3%, a fact that opens several possible applications.

  13. Detection and Classification of Baleen Whale Foraging Calls Combining Pattern Recognition and Machine Learning Techniques

    Science.gov (United States)

    2016-12-01

    for a call is also a time- consuming task. None of these chores bothers the analyst when applying the selection algorithm. With help from the...1365- 2907.2007.00106.x. Castellote, M., C. W. Clark, and M. O. Lammers, 2012: Acoustic and behavioural changes by fin whales (Balaenoptera physalus...separation of blue whale call types on a southern California feeding ground. Animal Behaviour , 74, 881–894, doi:10.1016/j.anbehav.2007.01.022. Rocha, R

  14. Determination of metals in air samples using X-Ray fluorescence associated the APDC preconcentration technique

    Energy Technology Data Exchange (ETDEWEB)

    Nardes, Raysa C.; Santos, Ramon S.; Sanches, Francis A.C.R.A.; Gama Filho, Hamilton S.; Oliveira, Davi F.; Anjos, Marcelino J., E-mail: rc.nardes@gmail.com, E-mail: ramonziosp@yahoo.com.br, E-mail: francissanches@gmail.com, E-mail: hamiltongamafilho@hotmail.com, E-mail: davi.oliveira@uerj.br, E-mail: marcelin@uerj.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Instituto de Fisica. Departamento de Fisica Aplicada e Termodinamica

    2015-07-01

    Air pollution has become one of the leading quality degradation factors of life for people in large urban centers. Studies indicate that the suspended particulate matter in the atmosphere is directly associated with risks to public health, in addition, it can cause damage to fauna, flora and public / cultural patrimonies. The inhalable particulate materials can cause the emergence and / or worsening of chronic diseases related to respiratory system and other diseases, such as reduced physical strength. In this study, we propose a new method to measure the concentration of total suspended particulate matter (TSP) in the air using an impinger as an air cleaning apparatus, preconcentration with APDC and Total Reflection X-ray Fluorescence technique (TXRF) to analyze the heavy metals present in the air. The samples were collected from five random points in the city of Rio de Janeiro/Brazil. Analyses of TXRF were performed at the Brazilian Synchrotron Light Laboratory (LNLS). The technique proved viable because it was able to detect five important metallic elements to environmental studies: Cr, Fe, Ni, Cu and Zn. This technique presented substantial efficiency in determining the elementary concentration of air pollutants, in addition to low cost. It can be concluded that the metals analysis technique in air samples using an impinger as sample collection instrument associated with a complexing agent (APDC) was viable because it is a low-cost technique, moreover, it was possible the detection of five important metal elements in environmental studies associated with industrial emissions and urban traffic. (author)

  15. Determination of metals in air samples using X-Ray fluorescence associated the APDC preconcentration technique

    International Nuclear Information System (INIS)

    Nardes, Raysa C.; Santos, Ramon S.; Sanches, Francis A.C.R.A.; Gama Filho, Hamilton S.; Oliveira, Davi F.; Anjos, Marcelino J.

    2015-01-01

    Air pollution has become one of the leading quality degradation factors of life for people in large urban centers. Studies indicate that the suspended particulate matter in the atmosphere is directly associated with risks to public health, in addition, it can cause damage to fauna, flora and public / cultural patrimonies. The inhalable particulate materials can cause the emergence and / or worsening of chronic diseases related to respiratory system and other diseases, such as reduced physical strength. In this study, we propose a new method to measure the concentration of total suspended particulate matter (TSP) in the air using an impinger as an air cleaning apparatus, preconcentration with APDC and Total Reflection X-ray Fluorescence technique (TXRF) to analyze the heavy metals present in the air. The samples were collected from five random points in the city of Rio de Janeiro/Brazil. Analyses of TXRF were performed at the Brazilian Synchrotron Light Laboratory (LNLS). The technique proved viable because it was able to detect five important metallic elements to environmental studies: Cr, Fe, Ni, Cu and Zn. This technique presented substantial efficiency in determining the elementary concentration of air pollutants, in addition to low cost. It can be concluded that the metals analysis technique in air samples using an impinger as sample collection instrument associated with a complexing agent (APDC) was viable because it is a low-cost technique, moreover, it was possible the detection of five important metal elements in environmental studies associated with industrial emissions and urban traffic. (author)

  16. A radioanalytical technique using (n,2n) reaction for the elemental analysis of samples

    International Nuclear Information System (INIS)

    Labor, M.

    1985-11-01

    A technique to determine elemental composition of samples is reported. The principle of the technique employs the internal standard method and involves the resolution of complex annihilation spectra. The technique has been applied to the determination of the mass of nitrogen, msub(N), and that of potassium, msub(K), in known masses of potassium nitrate. The percentage difference between the calculated mass and actual masses in 2g and 3g of potassium nitrate is 1.0 and 0.7 respectively for potassium, and 1.0 for nitrogen. The use of more simultaneous equations than necessary in solving for msub(N) and msub(K) offers one of the advantages of the technique. (author)

  17. Blended call center with idling times during the call service

    NARCIS (Netherlands)

    Legros, Benjamin; Jouini, Oualid; Koole, Ger

    We consider a blended call center with calls arriving over time and an infinitely backlogged amount of outbound jobs. Inbound calls have a non-preemptive priority over outbound jobs. The inbound call service is characterized by three successive stages where the second one is a break; i.e., there is

  18. Development of pulsation technique for single ion hit system

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Takuro; Hamano, Tsuyoshi; Hirao, Toshio; Kamiya, Tomihiro [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1996-12-01

    When a high energy heavy ion enters into a substance, high density of ionization and excitement occurrs along its flying trace. Especially, when such an ion enters into a semiconductor cell, a bit inversion called single event is occurred or a phenomenon destroyed element itself on case of the worst is formed. The present semiconductor cell is made in a size of some micron square, as different from its accumulated degree. In order to analyze the single event phenomenon formed by entering ion into such fine region in detail, a technique possible enter heavy ion beam with space resolution under 1 micron to each sample is necessary. In order to develop this technique, a static type high speed beam switch for control of entering a beam into a sample and a single ion detector for detecting entrance of ion into the sample were installed to heavy ion microbeam forming apparatus. The single ion hit system in Takasaki Radiation Chemistry Research Establishment, JAERI succeeded in detection and control technique of the single ion and control of noise due to pulsization and finished development of basic technique of the single ion hit, since now. After today, it is planned to hit actually the single ion onto the sample and evaluate its accuracy. (G.K.)

  19. A novel non-invasive diagnostic sampling technique for cutaneous leishmaniasis.

    Directory of Open Access Journals (Sweden)

    Yasaman Taslimi

    2017-07-01

    Full Text Available Accurate diagnosis of cutaneous leishmaniasis (CL is important for chemotherapy and epidemiological studies. Common approaches for Leishmania detection involve the invasive collection of specimens for direct identification of amastigotes by microscopy and the culturing of promastigotes from infected tissues. Although these techniques are highly specific, they require highly skilled health workers and have the inherent risks of all invasive procedures, such as pain and risk of bacterial and fungal super-infection. Therefore, it is essential to reduce discomfort, potential infection and scarring caused by invasive diagnostic approaches especially for children. In this report, we present a novel non-invasive method, that is painless, rapid and user-friendly, using sequential tape strips for sampling and isolation of DNA from the surface of active and healed skin lesions of CL patients. A total of 119 patients suspected of suffering from cutaneous leishmaniasis with different clinical manifestations were recruited and samples were collected both from their lesions and from uninfected areas. In addition, 15 fungal-infected lesions and 54 areas of healthy skin were examined. The duration of sampling is short (less than one minute and species identification by PCR is highly specific and sensitive. The sequential tape stripping sampling method is a sensitive, non-invasive and cost-effective alternative to traditional diagnostic assays and it is suitable for field studies as well as for use in health care centers.

  20. Multidisciplinary Responses to the Sexual Victimization of Children: Use of Control Phone Calls.

    Science.gov (United States)

    Canavan, J William; Borowski, Christine; Essex, Stacy; Perkowski, Stefan

    2017-10-01

    This descriptive study addresses the question of the value of one-party consent phone calls regarding the sexual victimization of children. The authors reviewed 4 years of experience with children between the ages of 3 and 18 years selected for the control phone calls after a forensic interview by the New York State Police forensic interviewer. The forensic interviewer identified appropriate cases for control phone calls considering New York State law, the child's capacity to make the call, the presence of another person to make the call and a supportive residence. The control phone call process has been extremely effective forensically. Offenders choose to avoid trial by taking a plea bargain thereby dramatically speeding up the criminal judicial and family court processes. An additional outcome of the control phone call is the alleged offender's own words saved the child from the trauma of testifying in court. The control phone call reduced the need for children to repeat their stories to various interviewers. A successful control phone call gives the child a sense of vindication. This technique is the only technique that preserves the actual communication pattern between the alleged victim and the alleged offender. This can be of great value to the mental health professionals working with both the child and the alleged offender. Cautions must be considered regarding potential serious adverse effects on the child. The multidisciplinary team members must work together in the control phone call. The descriptive nature of this study did not allow the authors adequate demographic data, a subject that should be addressed in future prospective study.

  1. Use of X-ray diffraction technique and chemometrics to aid soil sampling strategies in traceability studies.

    Science.gov (United States)

    Bertacchini, Lucia; Durante, Caterina; Marchetti, Andrea; Sighinolfi, Simona; Silvestri, Michele; Cocchi, Marina

    2012-08-30

    Aim of this work is to assess the potentialities of the X-ray powder diffraction technique as fingerprinting technique, i.e. as a preliminary tool to assess soil samples variability, in terms of geochemical features, in the context of food geographical traceability. A correct approach to sampling procedure is always a critical issue in scientific investigation. In particular, in food geographical traceability studies, where the cause-effect relations between the soil of origin and the final foodstuff is sought, a representative sampling of the territory under investigation is certainly an imperative. This research concerns a pilot study to investigate the field homogeneity with respect to both field extension and sampling depth, taking also into account the seasonal variability. Four Lambrusco production sites of the Modena district were considered. The X-Ray diffraction spectra, collected on the powder of each soil sample, were treated as fingerprint profiles to be deciphered by multivariate and multi-way data analysis, namely PCA and PARAFAC. The differentiation pattern observed in soil samples, as obtained by this fast and non-destructive analytical approach, well matches with the results obtained by characterization with other costly analytical techniques, such as ICP/MS, GFAAS, FAAS, etc. Thus, the proposed approach furnishes a rational basis to reduce the number of soil samples to be collected for further analytical characterization, i.e. metals content, isotopic ratio of radiogenic element, etc., while maintaining an exhaustive description of the investigated production areas. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Using Load Balancing to Scalably Parallelize Sampling-Based Motion Planning Algorithms

    KAUST Repository

    Fidel, Adam; Jacobs, Sam Ade; Sharma, Shishir; Amato, Nancy M.; Rauchwerger, Lawrence

    2014-01-01

    Motion planning, which is the problem of computing feasible paths in an environment for a movable object, has applications in many domains ranging from robotics, to intelligent CAD, to protein folding. The best methods for solving this PSPACE-hard problem are so-called sampling-based planners. Recent work introduced uniform spatial subdivision techniques for parallelizing sampling-based motion planning algorithms that scaled well. However, such methods are prone to load imbalance, as planning time depends on region characteristics and, for most problems, the heterogeneity of the sub problems increases as the number of processors increases. In this work, we introduce two techniques to address load imbalance in the parallelization of sampling-based motion planning algorithms: an adaptive work stealing approach and bulk-synchronous redistribution. We show that applying these techniques to representatives of the two major classes of parallel sampling-based motion planning algorithms, probabilistic roadmaps and rapidly-exploring random trees, results in a more scalable and load-balanced computation on more than 3,000 cores. © 2014 IEEE.

  3. Using Load Balancing to Scalably Parallelize Sampling-Based Motion Planning Algorithms

    KAUST Repository

    Fidel, Adam

    2014-05-01

    Motion planning, which is the problem of computing feasible paths in an environment for a movable object, has applications in many domains ranging from robotics, to intelligent CAD, to protein folding. The best methods for solving this PSPACE-hard problem are so-called sampling-based planners. Recent work introduced uniform spatial subdivision techniques for parallelizing sampling-based motion planning algorithms that scaled well. However, such methods are prone to load imbalance, as planning time depends on region characteristics and, for most problems, the heterogeneity of the sub problems increases as the number of processors increases. In this work, we introduce two techniques to address load imbalance in the parallelization of sampling-based motion planning algorithms: an adaptive work stealing approach and bulk-synchronous redistribution. We show that applying these techniques to representatives of the two major classes of parallel sampling-based motion planning algorithms, probabilistic roadmaps and rapidly-exploring random trees, results in a more scalable and load-balanced computation on more than 3,000 cores. © 2014 IEEE.

  4. Sample preparation for large-scale bioanalytical studies based on liquid chromatographic techniques.

    Science.gov (United States)

    Medvedovici, Andrei; Bacalum, Elena; David, Victor

    2018-01-01

    Quality of the analytical data obtained for large-scale and long term bioanalytical studies based on liquid chromatography depends on a number of experimental factors including the choice of sample preparation method. This review discusses this tedious part of bioanalytical studies, applied to large-scale samples and using liquid chromatography coupled with different detector types as core analytical technique. The main sample preparation methods included in this paper are protein precipitation, liquid-liquid extraction, solid-phase extraction, derivatization and their versions. They are discussed by analytical performances, fields of applications, advantages and disadvantages. The cited literature covers mainly the analytical achievements during the last decade, although several previous papers became more valuable in time and they are included in this review. Copyright © 2017 John Wiley & Sons, Ltd.

  5. Gotta Go, Mom’s Calling: Dolphin (Tursiops truncatus Mothers Use Individually Distinctive Acoustic Signals To Call Their Calves

    Directory of Open Access Journals (Sweden)

    Stan A. Kuczaj II

    2015-02-01

    Full Text Available Dolphin calves often wander away from their mothers, which can compromise their safety and survival. Mothers can retrieve their calves by actively pursuing them or by signaling their wandering calves to return. However, little is known about the retrieval techniques employed by mothers in specific calf recall contexts. We experimentally investigated maternal calf retrieval methods by assessing behavioral and acoustic strategies employed by three Atlantic bottlenose dolphin mothers to elicit their calf’s return in a controlled, non-threatening setting. Three mothers were asked to retrieve their calves on cue in this setting, and could do so however they chose. Mothers were much more likely to use energetically less costly acoustic signals than physical retrievals. Each mother produced individually distinctive calls that incorporated the mother’s signature whistle but often also involved additional whistles and clicks. The dolphin mothers’ use of individually distinctive calls to request a calf’s return is consistent with the notion that other dolphins can distinguish such calls and provides additional support for the notion that dolphin communication is flexible rather than fixed.

  6. Use of an oscillation technique to measure effective cross-sections of fissionable samples in critical assemblies

    International Nuclear Information System (INIS)

    Tretiakoff, O.; Vidal, R.; Carre, J.C.; Robin, M.

    1964-01-01

    The authors describe the technique used to measure the effective absorption and neutron-yield cross-sections of a fissionable sample. These two values are determined by analysing the signals due to the variation in reactivity (over-all signal) and the local perturbation in the flux (local signal) produced by the oscillating sample. These signals are standardized by means of a set of samples containing quantities of fissionable material ( 235 U) and an absorber, boron, which are well known. The measurements are made for different neutron spectra characterized by lattice parameters which constitute the central zone within which the sample moves. This technique is used to study the effective cross-sections of uranium-plutonium alloys for different heavy-water and graphite lattices in the MINERVE and MARIUS critical assemblies. The same experiments are carried out on fuel samples of different irradiations in order to determine the evolution of effective cross-sections as a function of the spectrum and the irradiations. (authors) [fr

  7. Inorganic elements determination in human and animal whole blood samples by X-ray fluorescence technique (EDXRF)

    International Nuclear Information System (INIS)

    Redigolo, Marcelo Miyada

    2011-01-01

    Blood is a suspension of cells contained in a complex liquid called plasma. The term 'whole blood' refers to samples with both solid and liquid parts. Inorganic elements are responsible for essential functions, such as osmotic regulation, cardiac frequency and contractibility, blood clotting and neuromuscular excitability. The determination of inorganic elements in corporeal fluids such as blood, serum, plasma, tissue and urine is used as a monitor for a part or the whole organism. In this work, the X-Ray fluorescence technique (EDXRF) was used for the determination of inorganic elements in whole blood samples from humans and animals (golden hamsters, Mesocricetus auratus and crioula breed horses, Equus caballus). The reference intervals of Na (1788 - 1826 μg g'- 1 ), Mg (63 - 75 μg g -1 ), P (602 - 676 μg g -1 ), S (1519 - 1718 μg g -1 ), Cl (2743 - 2867 μg g -1 ), K (1508 - 1630 μg g -1 ), Ca (214 - 228 μg g'- 1 ), Cu (4 -6 μg g -1 ) e Zn (1 - 3 μg g'- 1 ) were determined for human blood. The reference intervals, for golden hamster blood were found to be: Na (1714 - 1819 μg g -1 ), Mg (51 - 79 μg g -1 ), P (970 - 1080 μg g -1 ), S (1231 - 1739 μg g -1 ), Cl (2775 - 2865 μg g -1 ), K (1968 - 2248 μg g -1 ), Ca (209 - 257 μg g-1), Cu (4 - 6 μg g -1 ) e Zn (3 - 5 μg g -1 ). The reference intervals, for crioula breed horse blood, showed to be: Na (1955 - 2013 μg g -1 ), Mg (51 - 75 μg g -1 ), P (443 - 476 μg g -1 ), S (1038 - 1140 μg g - '1), Cl (2388 - 2574 μg g -1 ), K (1678 - 1753 μg g -1 ), Ca (202 - 213 μg g -1 ), Cu (4,1 - 4,5 μg g -1 ) e Zn (2,0 - 2,2 μg g -1 ). Comparative study between NAA and EDXRF, both techniques showed the same performance for the analyses of biological matrices. The results contribute for the establishment of reference intervals for the Brazilian healthy population and the referred animal species. (author)

  8. Toward greener analytical techniques for the absolute quantification of peptides in pharmaceutical and biological samples.

    Science.gov (United States)

    Van Eeckhaut, Ann; Mangelings, Debby

    2015-09-10

    Peptide-based biopharmaceuticals represent one of the fastest growing classes of new drug molecules. New reaction types included in the synthesis strategies to reduce the rapid metabolism of peptides, along with the availability of new formulation and delivery technologies, resulted in an increased marketing of peptide drug products. In this regard, the development of analytical methods for quantification of peptides in pharmaceutical and biological samples is of utmost importance. From the sample preparation step to their analysis by means of chromatographic or electrophoretic methods, many difficulties should be tackled to analyze them. Recent developments in analytical techniques emphasize more and more on the use of green analytical techniques. This review will discuss the progresses in and challenges observed during green analytical method development for the quantification of peptides in pharmaceutical and biological samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Statistical sampling applied to the radiological characterization of historical waste

    Directory of Open Access Journals (Sweden)

    Zaffora Biagio

    2016-01-01

    Full Text Available The evaluation of the activity of radionuclides in radioactive waste is required for its disposal in final repositories. Easy-to-measure nuclides, like γ-emitters and high-energy X-rays, can be measured via non-destructive nuclear techniques from outside a waste package. Some radionuclides are difficult-to-measure (DTM from outside a package because they are α- or β-emitters. The present article discusses the application of linear regression, scaling factors (SF and the so-called “mean activity method” to estimate the activity of DTM nuclides on metallic waste produced at the European Organization for Nuclear Research (CERN. Various statistical sampling techniques including simple random sampling, systematic sampling, stratified and authoritative sampling are described and applied to 2 waste populations of activated copper cables. The bootstrap is introduced as a tool to estimate average activities and standard errors in waste characterization. The analysis of the DTM Ni-63 is used as an example. Experimental and theoretical values of SFs are calculated and compared. Guidelines for sampling historical waste using probabilistic and non-probabilistic sampling are finally given.

  10. A cost-effective technique for integrating personal radiation dose assessment with personal gravimetric sampling

    International Nuclear Information System (INIS)

    Strydom, R.; Rolle, R.; Van der Linde, A.

    1992-01-01

    During recent years there has been an increasing awareness internationally of radiation levels in the mining and milling of radioactive ores, including those from non-uranium mines. A major aspect of radiation control is concerned with the measurement of radiation levels and the assessment of radiation doses incurred by individual workers. Current techniques available internationally for personnel monitoring of radiation exposures are expensive and there is a particular need to reduce the cost of personal radiation monitoring in South African gold mines because of the large labour force employed. In this regard the obvious benefits of integrating personal radiation monitoring with existing personal monitoring systems already in place in South African gold mines should be exploited. A system which can be utilized for this purpose is personal gravimetric sampling. A new cost-effective technique for personal radiation monitoring, which can be fully integrated with the personal gravimetric sampling strategy being implemented on mines, has been developed in South Africa. The basic principles of this technique and its potential in South African mines are described. 9 refs., 7 figs

  11. 238U And 232Th Concentration In Rock Samples using Alpha Autoradiography and Gamma Spectroscopy Techniques

    International Nuclear Information System (INIS)

    Hafez, A.F.; El-Farrash, A.H.; Yousef, H.A.

    2009-01-01

    The activity concentrations of uranium and thorium were measured for some rock samples selected from Dahab region in the south tip of Sinai. In order to detect any harmful radiation that would affect on the tourists and is becoming economic resource because Dahab have open fields of tourism in Egypt. The activity concentration of uranium and thorium in rocks samples was measured using two techniques. The first is .-autoradiography technique with LR-115 and CR-39 detectors and the second is gamma spectroscopic technique with NaI(Tl) detector. It was found that the average activity concentrations of uranium and thorium using .-autoradiography technique ranged from 6.41-49.31 Bqkg-1, 4.86- 40.87 Bqkg-1 respectively and by gamma detector are ranged from 6.70- 49.50 Bqkg-1, 4.47- 42.33 Bqkg-1 respectively. From the obtained data we can conclude that there is no radioactive healthy hazard for human and living beings in the area under investigation. It was found that there are no big differences between the calculated thorium to uranium ratios in both techniques

  12. Atmospheric pressure surface sampling/ionization techniques for direct coupling of planar separations with mass spectrometry.

    Science.gov (United States)

    Pasilis, Sofie P; Van Berkel, Gary J

    2010-06-18

    Planar separations, which include thin layer chromatography and gel electrophoresis, are in widespread use as important and powerful tools for conducting separations of complex mixtures. To increase the utility of planar separations, new methods are needed that allow in situ characterization of the individual components of the separated mixtures. A large number of atmospheric pressure surface sampling and ionization techniques for use with mass spectrometry have emerged in the past several years, and several have been investigated as a means for mass spectrometric read-out of planar separations. In this article, we review the atmospheric pressure surface sampling and ionization techniques that have been used for the read-out of planar separation media. For each technique, we briefly explain the operational basics and discuss the analyte type for which it is appropriate and some specific applications from the literature. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  13. Waste minimization in analytical chemistry through innovative sample preparation techniques

    International Nuclear Information System (INIS)

    Smith, L. L.

    1998-01-01

    water samples. In this SPME technique, a fused-silica fiber coated with a polymeric film is exposed to the sample, extraction is allowed to take place, and then the analytes are thermally desorbed for GC analysis. Unlike liquid-liquid extraction or solid-phase extraction, SPME consumes all of the extracted sample in the analysis, significantly reducing the required sample volume

  14. High-throughput droplet analysis and multiplex DNA detection in the microfluidic platform equipped with a robust sample-introduction technique

    International Nuclear Information System (INIS)

    Chen, Jinyang; Ji, Xinghu; He, Zhike

    2015-01-01

    In this work, a simple, flexible and low-cost sample-introduction technique was developed and integrated with droplet platform. The sample-introduction strategy was realized based on connecting the components of positive pressure input device, sample container and microfluidic chip through the tygon tubing with homemade polydimethylsiloxane (PDMS) adaptor, so the sample was delivered into the microchip from the sample container under the driving of positive pressure. This sample-introduction technique is so robust and compatible that could be integrated with T-junction, flow-focus or valve-assisted droplet microchips. By choosing the PDMS adaptor with proper dimension, the microchip could be flexibly equipped with various types of familiar sample containers, makes the sampling more straightforward without trivial sample transfer or loading. And the convenient sample changing was easily achieved by positioning the adaptor from one sample container to another. Benefiting from the proposed technique, the time-dependent concentration gradient was generated and applied for quantum dot (QD)-based fluorescence barcoding within droplet chip. High-throughput droplet screening was preliminarily demonstrated through the investigation of the quenching efficiency of ruthenium complex to the fluorescence of QD. More importantly, multiplex DNA assay was successfully carried out in the integrated system, which shows the practicability and potentials in high-throughput biosensing. - Highlights: • A simple, robust and low-cost sample-introduction technique was developed. • Convenient and flexible sample changing was achieved in microfluidic system. • Novel strategy of concentration gradient generation was presented for barcoding. • High-throughput droplet screening could be realized in the integrated platform. • Multiplex DNA assay was successfully carried out in the droplet platform

  15. High-throughput droplet analysis and multiplex DNA detection in the microfluidic platform equipped with a robust sample-introduction technique

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jinyang; Ji, Xinghu [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); He, Zhike, E-mail: zhkhe@whu.edu.cn [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); Suzhou Institute of Wuhan University, Suzhou 215123 (China)

    2015-08-12

    In this work, a simple, flexible and low-cost sample-introduction technique was developed and integrated with droplet platform. The sample-introduction strategy was realized based on connecting the components of positive pressure input device, sample container and microfluidic chip through the tygon tubing with homemade polydimethylsiloxane (PDMS) adaptor, so the sample was delivered into the microchip from the sample container under the driving of positive pressure. This sample-introduction technique is so robust and compatible that could be integrated with T-junction, flow-focus or valve-assisted droplet microchips. By choosing the PDMS adaptor with proper dimension, the microchip could be flexibly equipped with various types of familiar sample containers, makes the sampling more straightforward without trivial sample transfer or loading. And the convenient sample changing was easily achieved by positioning the adaptor from one sample container to another. Benefiting from the proposed technique, the time-dependent concentration gradient was generated and applied for quantum dot (QD)-based fluorescence barcoding within droplet chip. High-throughput droplet screening was preliminarily demonstrated through the investigation of the quenching efficiency of ruthenium complex to the fluorescence of QD. More importantly, multiplex DNA assay was successfully carried out in the integrated system, which shows the practicability and potentials in high-throughput biosensing. - Highlights: • A simple, robust and low-cost sample-introduction technique was developed. • Convenient and flexible sample changing was achieved in microfluidic system. • Novel strategy of concentration gradient generation was presented for barcoding. • High-throughput droplet screening could be realized in the integrated platform. • Multiplex DNA assay was successfully carried out in the droplet platform.

  16. The novel programmable riometer for in-depth ionospheric and magnetospheric observations (PRIAMOS) using direct sampling DSP techniques

    OpenAIRE

    Dekoulis, G.; Honary, F.

    2005-01-01

    This paper describes the feasibility study and simulation results for the unique multi-frequency, multi-bandwidth, Programmable Riometer for in-depth Ionospheric And Magnetospheric ObservationS (PRIAMOS) based on direct sampling digital signal processing (DSP) techniques. This novel architecture is based on sampling the cosmic noise wavefront at the antenna. It eliminates the usage of any intermediate frequency (IF) mixer stages (-6 dB) and the noise balancing technique (-3 dB), providing a m...

  17. Laser-Assisted Sampling Techniques in Combination with ICP-MS: A Novel Approach for Particle Analysis at the IAEA Environmental Samples Laboratory

    International Nuclear Information System (INIS)

    Dzigal, N.; Chinea-Cano, E.

    2015-01-01

    Researchers have found many applications for lasers. About two decades ago, scientists started using lasers as sample introduction instruments for mass spectrometry measurements. Similarly, lasers as micro-dissection tools have also been increasingly on demand in the fields of life sciences, materials science, forensics, etc. This presentation deals with the interception of these aforementioned laser-assisted techniques to the field of particle analysis. Historically, the use of a nanosecond laser to ablate material has been used in materials science. Recently, it has been proven that in the analysis of particulate materials the disadvantages associated with the utilization of nanosecond lasers such as overheating and melting of the sample are suppressed when using femtosecond lasers. Further, due to the length of a single laser shot, fs-LA allows a more controlled ablation to occur and therefore the sample plasma is more homogeneous and less mass-fractionation events are detected. The use of laser micro-dissection devices enables the physical segmentation of microsized artefacts previously performed by a laborious manual procedure. By combining the precision of the laser cutting inherent to the LMD technique together with a particle identification methodology, one can increase the efficiency of single particle isolation. Further, besides the increase in throughput of analyses, this combination enhances the signal-to-noise ratio by removing matrix particles effectively. Specifically, this contribution describes the use of an Olympus+MMI laser microdissection device in improving the sample preparation of environmental swipe samples and the installation of an Applied Spectra J200 fs-LA/LIBS (laser ablation/laser inducedbreakdown spectroscopy) system as a sample introduction device to a quadrupole mass spectrometer, the iCap Q from Thermofisher Scientific at the IAEA Environmental Samples Laboratory are explored. Preliminary results of the ongoing efforts for the

  18. Thermophilic Campylobacter spp. in turkey samples: evaluation of two automated enzyme immunoassays and conventional microbiological techniques

    DEFF Research Database (Denmark)

    Borck, Birgitte; Stryhn, H.; Ersboll, A.K.

    2002-01-01

    Aims: To determine the sensitivity and specificity of two automated enzyme immunoassays (EIA), EiaFoss and Minividas, and a conventional microbiological culture technique for detecting thermophilic Campylobacter spp. in turkey samples. Methods and Results: A total of 286 samples (faecal, meat...

  19. Solving mercury (Hg) speciation in soil samples by synchrotron X-ray microspectroscopic techniques.

    Science.gov (United States)

    Terzano, Roberto; Santoro, Anna; Spagnuolo, Matteo; Vekemans, Bart; Medici, Luca; Janssens, Koen; Göttlicher, Jörg; Denecke, Melissa A; Mangold, Stefan; Ruggiero, Pacifico

    2010-08-01

    Direct mercury (Hg) speciation was assessed for soil samples with a Hg concentration ranging from 7 up to 240 mg kg(-1). Hg chemical forms were identified and quantified by sequential extractions and bulk- and micro-analytical techniques exploiting synchrotron generated X-rays. In particular, microspectroscopic techniques such as mu-XRF, mu-XRD and mu-XANES were necessary to solve bulk Hg speciation, in both soil fractions soil samples were metacinnabar (beta-HgS), cinnabar (alpha-HgS), corderoite (Hg(3)S(2)Cl(2)), and an amorphous phase containing Hg bound to chlorine and sulfur. The amount of metacinnabar and amorphous phases increased in the fraction soil components was observed. All the observed Hg-species originated from the slow weathering of an inert Hg-containing waste material (K106, U.S. EPA) dumped in the area several years ago, which is changing into a relatively more dangerous source of pollution. Copyright 2010 Elsevier Ltd. All rights reserved.

  20. Efficiently sampling conformations and pathways using the concurrent adaptive sampling (CAS) algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Surl-Hee; Grate, Jay W.; Darve, Eric F.

    2017-08-21

    Molecular dynamics (MD) simulations are useful in obtaining thermodynamic and kinetic properties of bio-molecules but are limited by the timescale barrier, i.e., we may be unable to efficiently obtain properties because we need to run microseconds or longer simulations using femtoseconds time steps. While there are several existing methods to overcome this timescale barrier and efficiently sample thermodynamic and/or kinetic properties, problems remain in regard to being able to sample un- known systems, deal with high-dimensional space of collective variables, and focus the computational effort on slow timescales. Hence, a new sampling method, called the “Concurrent Adaptive Sampling (CAS) algorithm,” has been developed to tackle these three issues and efficiently obtain conformations and pathways. The method is not constrained to use only one or two collective variables, unlike most reaction coordinate-dependent methods. Instead, it can use a large number of collective vari- ables and uses macrostates (a partition of the collective variable space) to enhance the sampling. The exploration is done by running a large number of short simula- tions, and a clustering technique is used to accelerate the sampling. In this paper, we introduce the new methodology and show results from two-dimensional models and bio-molecules, such as penta-alanine and triazine polymer

  1. Coherent optical adaptive technique improves the spatial resolution of STED microscopy in thick samples

    Science.gov (United States)

    Yan, Wei; Yang, Yanlong; Tan, Yu; Chen, Xun; Li, Yang; Qu, Junle; Ye, Tong

    2018-01-01

    Stimulated emission depletion microscopy (STED) is one of far-field optical microscopy techniques that can provide sub-diffraction spatial resolution. The spatial resolution of the STED microscopy is determined by the specially engineered beam profile of the depletion beam and its power. However, the beam profile of the depletion beam may be distorted due to aberrations of optical systems and inhomogeneity of specimens’ optical properties, resulting in a compromised spatial resolution. The situation gets deteriorated when thick samples are imaged. In the worst case, the sever distortion of the depletion beam profile may cause complete loss of the super resolution effect no matter how much depletion power is applied to specimens. Previously several adaptive optics approaches have been explored to compensate aberrations of systems and specimens. However, it is hard to correct the complicated high-order optical aberrations of specimens. In this report, we demonstrate that the complicated distorted wavefront from a thick phantom sample can be measured by using the coherent optical adaptive technique (COAT). The full correction can effectively maintain and improve the spatial resolution in imaging thick samples. PMID:29400356

  2. Multiple sensitive estimation and optimal sample size allocation in the item sum technique.

    Science.gov (United States)

    Perri, Pier Francesco; Rueda García, María Del Mar; Cobo Rodríguez, Beatriz

    2018-01-01

    For surveys of sensitive issues in life sciences, statistical procedures can be used to reduce nonresponse and social desirability response bias. Both of these phenomena provoke nonsampling errors that are difficult to deal with and can seriously flaw the validity of the analyses. The item sum technique (IST) is a very recent indirect questioning method derived from the item count technique that seeks to procure more reliable responses on quantitative items than direct questioning while preserving respondents' anonymity. This article addresses two important questions concerning the IST: (i) its implementation when two or more sensitive variables are investigated and efficient estimates of their unknown population means are required; (ii) the determination of the optimal sample size to achieve minimum variance estimates. These aspects are of great relevance for survey practitioners engaged in sensitive research and, to the best of our knowledge, were not studied so far. In this article, theoretical results for multiple estimation and optimal allocation are obtained under a generic sampling design and then particularized to simple random sampling and stratified sampling designs. Theoretical considerations are integrated with a number of simulation studies based on data from two real surveys and conducted to ascertain the efficiency gain derived from optimal allocation in different situations. One of the surveys concerns cannabis consumption among university students. Our findings highlight some methodological advances that can be obtained in life sciences IST surveys when optimal allocation is achieved. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Sampling and sample preparation development for analytical and on-line measurement techniques of process liquids; Naeytteenoton ja kaesittelyn kehittaeminen prosessinesteiden analytiikan ja on-line mittaustekniikan tarpeisiin - MPKT 11

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, K. [Oulu Univ. (Finland)

    1998-12-31

    Main goal of the research project is to develop sampling and sample handling methods and techniques for pulp and paper industry to be used for analysis and on-line purposes. The research focus specially on the research and development of the classification and separation methods and techniques needed for liquid and colloidal substances as well as in ion analysis. (orig.)

  4. Sampling and sample preparation development for analytical and on-line measurement techniques of process liquids; Naeytteenoton ja kaesittelyn kehittaeminen prosessinesteiden analytiikan ja on-line mittaustekniikan tarpeisiin - MPKT 11

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, K [Oulu Univ. (Finland)

    1999-12-31

    Main goal of the research project is to develop sampling and sample handling methods and techniques for pulp and paper industry to be used for analysis and on-line purposes. The research focus specially on the research and development of the classification and separation methods and techniques needed for liquid and colloidal substances as well as in ion analysis. (orig.)

  5. Wireless recording of the calls of Rousettus aegyptiacus and their reproduction using electrostatic transducers

    International Nuclear Information System (INIS)

    Whiteley, S M; Hayward, G; Pierce, S G; Waters, D A; Farr, I

    2010-01-01

    Bats are capable of imaging their surroundings in great detail using echolocation. To apply similar methods to human engineering systems requires the capability to measure and recreate the signals used, and to understand the processing applied to returning echoes. In this work, the emitted and reflected echolocation signals of Rousettus aegyptiacus are recorded while the bat is in flight, using a wireless sensor mounted on the bat. The sensor is designed to replicate the acoustic gain control which bats are known to use, applying a gain to returning echoes that is dependent on the incurred time delay. Employing this technique allows emitted and reflected echolocation calls, which have a wide dynamic range, to be recorded. The recorded echoes demonstrate the complexity of environment reconstruction using echolocation. The sensor is also used to make accurate recordings of the emitted calls, and these calls are recreated in the laboratory using custom-built wideband electrostatic transducers, allied with a spectral equalization technique. This technique is further demonstrated by recreating multi-harmonic bioinspired FM chirps. The ability to record and accurately synthesize echolocation calls enables the exploitation of biological signals in human engineering systems for sonar, materials characterization and imaging.

  6. Use of SCGE method for detection of DNA comet in irradiated samples of poultry and shrimp

    International Nuclear Information System (INIS)

    Rajaei, R.; Hosseini, S.L.

    2005-01-01

    DNA in food may sustain damage by gamma irradiation.This damage can be detected by a sensitive technique, called single cell gel electrophoresis. This is a simple and low-cost technique for rapid screening of the cells of irradiated foodstuffs. For this purpose, poultry and shrimp samples were irradiated by the 60 Co gamma radiation. The radiation doses for poultry were 2,5 and 7 kGy and for shrimp were 3 and 7kGy, respectively. The irradiation samples were compared with those of unirradiated types (control). In addition, the effects of shelf-life and temperature were considered on the poultry samples only. We have found that this technique is easily applicable for identification of irradiated from unirradiated samples and it is found to be irrespective of the applied dose. It is worth mentioning that any DNA change arising from any source, for example temperature fluctuation, may be detected by the single cell gel electrophoresis technique

  7. Estimation of trace levels of plutonium in urine samples by fission track technique

    International Nuclear Information System (INIS)

    Sawant, P.D.; Prabhu, S.; Pendharkar, K.A.; Kalsi, P.C.

    2009-01-01

    Individual monitoring of radiation workers handling Pu in various nuclear installations requires the detection of trace levels of plutonium in bioassay samples. It is necessary to develop methods that can detect urinary excretion of Pu in fraction of mBq range. Therefore, a sensitive method such as fission track analysis has been developed for the measurement of trace levels of Pu in bioassay samples. In this technique, chemically separated plutonium from the sample and a Pu standard were electrodeposited on planchettes and covered with Lexan solid state nuclear track detector (SSNTD) and irradiated with thermal neutrons in APSARA reactor of Bhabha Atomic Research Centre, India. The fission track densities in the Lexan films of the sample and the standard were used to calculate the amount of Pu in the sample. The minimum amount of Pu that can be analyzed by this method using doubly distilled electronic grade (E. G.) reagents is about 12 μBq/L. (author)

  8. Fabrication Techniques of Stretchable and Cloth Electroadhesion Samples for Implementation on Devices with Space Application

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of this study is to determine materials and fabrication techniques for efficient space-rated electroadhesion (EA) samples. Liquid metals, including...

  9. Insights into N-calls of mitochondrial DNA sequencing using MitoChip v2.0

    Directory of Open Access Journals (Sweden)

    Blakely Emma L

    2011-10-01

    Full Text Available Abstract Background Developments in DNA resequencing microarrays include mitochondrial DNA (mtDNA sequencing and mutation detection. Failure by the microarray to identify a base, compared to the reference sequence, is designated an 'N-call.' This study re-examined the N-call distribution of mtDNA samples sequenced by the Affymetrix MitoChip v.2.0, based on the hypothesis that N-calls may represent insertions or deletions (indels in mtDNA. Findings We analysed 16 patient mtDNA samples using MitoChip. N-calls by the proprietary GSEQ software were significantly reduced when either of the freeware on-line algorithms ResqMi or sPROFILER was utilized. With sPROFILER, this decrease in N-calls had no effect on the homoplasmic or heteroplasmic mutation levels compared to GSEQ software, but ResqMi produced a significant change in mutation load, as well as producing longer N-cell stretches. For these reasons, further analysis using ResqMi was not attempted. Conventional DNA sequencing of the longer N-calls stretches from sPROFILER revealed 7 insertions and 12 point mutations. Moreover, analysis of single-base N-calls of one mtDNA sample found 3 other point mutations. Conclusions Our study is the first to analyse N-calls produced from GSEQ software for the MitoChipv2.0. By narrowing the focus to longer stretches of N-calls revealed by sPROFILER, conventional sequencing was able to identify unique insertions and point mutations. Shorter N-calls also harboured point mutations, but the absence of deletions among N-calls suggests that probe confirmation affects binding and thus N-calling. This study supports the contention that the GSEQ is more capable of assigning bases when used in conjunction with sPROFILER.

  10. A review of analytical techniques for the determination of carbon-14 in environmental samples

    International Nuclear Information System (INIS)

    Milton, G.M.; Brown, R.M.

    1993-11-01

    This report contains a brief summary of analytical techniques commonly used for the determination of radiocarbon in a variety of environmental samples. Details of the applicable procedures developed and tested in the Environmental Research Branch at Chalk River Laboratories are appended

  11. Techniques for the detection of pathogenic Cryptococcus species in wood decay substrata and the evaluation of viability in stored samples

    Directory of Open Access Journals (Sweden)

    Christian Alvarez

    2013-02-01

    Full Text Available In this study, we evaluated several techniques for the detection of the yeast form of Cryptococcus in decaying wood and measured the viability of these fungi in environmental samples stored in the laboratory. Samples were collected from a tree known to be positive for Cryptococcus and were each inoculated on 10 Niger seed agar (NSA plates. The conventional technique (CT yielded a greater number of positive samples and indicated a higher fungal density [in colony forming units per gram of wood (CFU.g-1] compared to the humid swab technique (ST. However, the difference in positive and false negative results between the CT-ST was not significant. The threshold of detection for the CT was 0.05.10³ CFU.g-1, while the threshold for the ST was greater than 0.1.10³ CFU-1. No colonies were recovered using the dry swab technique. We also determined the viability of Cryptococcus in wood samples stored for 45 days at 25ºC using the CT and ST and found that samples not only continued to yield a positive response, but also exhibited an increase in CFU.g-1, suggesting that Cryptococcus is able to grow in stored environmental samples. The ST.1, in which samples collected with swabs were immediately plated on NSA medium, was more efficient and less laborious than either the CT or ST and required approximately 10 min to perform; however, additional studies are needed to validate this technique.

  12. Mobile telephones: a comparison of radiated power between 3G VoIP calls and 3G VoCS calls.

    Science.gov (United States)

    Jovanovic, Dragan; Bragard, Guillaume; Picard, Dominique; Chauvin, Sébastien

    2015-01-01

    The purpose of this study is to assess the mean RF power radiated by mobile telephones during voice calls in 3G VoIP (Voice over Internet Protocol) using an application well known to mobile Internet users, and to compare it with the mean power radiated during voice calls in 3G VoCS (Voice over Circuit Switch) on a traditional network. Knowing that the specific absorption rate (SAR) is proportional to the mean radiated power, the user's exposure could be clearly identified at the same time. Three 3G (High Speed Packet Access) smartphones from three different manufacturers, all dual-band for GSM (900 MHz, 1800 MHz) and dual-band for UMTS (900 MHz, 1950 MHz), were used between 28 July and 04 August 2011 in Paris (France) to make 220 two-minute calls on a mobile telephone network with national coverage. The places where the calls were made were selected in such a way as to describe the whole range of usage situations of the mobile telephone. The measuring equipment, called "SYRPOM", recorded the radiation power levels and the frequency bands used during the calls with a sampling rate of 20,000 per second. In the framework of this study, the mean normalised power radiated by a telephone in 3G VoIP calls was evaluated at 0.75% maximum power of the smartphone, compared with 0.22% in 3G VoCS calls. The very low average power levels associated with use of 3G devices with VoIP or VoCS support the view that RF exposure resulting from their use is far from exceeding the basic restrictions of current exposure limits in terms of SAR.

  13. Investigation of CPD and HMDS Sample Preparation Techniques for Cervical Cells in Developing Computer-Aided Screening System Based on FE-SEM/EDX

    Science.gov (United States)

    Ng, Siew Cheok; Abu Osman, Noor Azuan

    2014-01-01

    This paper investigated the effects of critical-point drying (CPD) and hexamethyldisilazane (HMDS) sample preparation techniques for cervical cells on field emission scanning electron microscopy and energy dispersive X-ray (FE-SEM/EDX). We investigated the visualization of cervical cell image and elemental distribution on the cervical cell for two techniques of sample preparation. Using FE-SEM/EDX, the cervical cell images are captured and the cell element compositions are extracted for both sample preparation techniques. Cervical cell image quality, elemental composition, and processing time are considered for comparison of performances. Qualitatively, FE-SEM image based on HMDS preparation technique has better image quality than CPD technique in terms of degree of spread cell on the specimen and morphologic signs of cell deteriorations (i.e., existence of plate and pellet drying artifacts and membrane blebs). Quantitatively, with mapping and line scanning EDX analysis, carbon and oxygen element compositions in HMDS technique were higher than the CPD technique in terms of weight percentages. The HMDS technique has shorter processing time than the CPD technique. The results indicate that FE-SEM imaging, elemental composition, and processing time for sample preparation with the HMDS technique were better than CPD technique for cervical cell preparation technique for developing computer-aided screening system. PMID:25610902

  14. Dynamic call center routing policies using call waiting and agent idle times

    NARCIS (Netherlands)

    Chan, W.; Koole, G.M.; L'Ecuyer, P.

    2014-01-01

    We study call routing policies for call centers with multiple call types and multiple agent groups. We introduce new weight-based routing policies where each pair (call type, agent group) is given a matching priority defined as an affine combination of the longest waiting time for that call type and

  15. Clinical application of microsampling versus conventional sampling techniques in the quantitative bioanalysis of antibiotics: a systematic review.

    Science.gov (United States)

    Guerra Valero, Yarmarly C; Wallis, Steven C; Lipman, Jeffrey; Stove, Christophe; Roberts, Jason A; Parker, Suzanne L

    2018-03-01

    Conventional sampling techniques for clinical pharmacokinetic studies often require the removal of large blood volumes from patients. This can result in a physiological or emotional burden, particularly for neonates or pediatric patients. Antibiotic pharmacokinetic studies are typically performed on healthy adults or general ward patients. These may not account for alterations to a patient's pathophysiology and can lead to suboptimal treatment. Microsampling offers an important opportunity for clinical pharmacokinetic studies in vulnerable patient populations, where smaller sample volumes can be collected. This systematic review provides a description of currently available microsampling techniques and an overview of studies reporting the quantitation and validation of antibiotics using microsampling. A comparison of microsampling to conventional sampling in clinical studies is included.

  16. Elemental analysis of brazing alloy samples by neutron activation technique

    International Nuclear Information System (INIS)

    Eissa, E.A.; Rofail, N.B.; Hassan, A.M.; El-Shershaby, A.; Walley El-Dine, N.

    1996-01-01

    Two brazing alloy samples (C P 2 and C P 3 ) have been investigated by Neutron activation analysis (NAA) technique in order to identify and estimate their constituent elements. The pneumatic irradiation rabbit system (PIRS), installed at the first egyptian research reactor (ETRR-1) was used for short-time irradiation (30 s) with a thermal neutron flux of 1.6 x 10 1 1 n/cm 2 /s in the reactor reflector, where the thermal to epithermal neutron flux ratio is 106. Long-time irradiation (48 hours) was performed at reactor core periphery with thermal neutron flux of 3.34 x 10 1 2 n/cm 2 /s, and thermal to epithermal neutron flux ratio of 79. Activation by epithermal neutrons was taken into account for the (1/v) and resonance neutron absorption in both methods. A hyper pure germanium detection system was used for gamma-ray acquisitions. The concentration values of Al, Cr, Fe, Co, Cu, Zn, Se, Ag and Sb were estimated as percentages of the sample weight and compared with reported values. 1 tab

  17. Elemental analysis of brazing alloy samples by neutron activation technique

    Energy Technology Data Exchange (ETDEWEB)

    Eissa, E A; Rofail, N B; Hassan, A M [Reactor and Neutron physics Department, Nuclear Research Centre, Atomic Energy Authority, Cairo (Egypt); El-Shershaby, A; Walley El-Dine, N [Physics Department, Faculty of Girls, Ain Shams Universty, Cairo (Egypt)

    1997-12-31

    Two brazing alloy samples (C P{sup 2} and C P{sup 3}) have been investigated by Neutron activation analysis (NAA) technique in order to identify and estimate their constituent elements. The pneumatic irradiation rabbit system (PIRS), installed at the first egyptian research reactor (ETRR-1) was used for short-time irradiation (30 s) with a thermal neutron flux of 1.6 x 10{sup 1}1 n/cm{sup 2}/s in the reactor reflector, where the thermal to epithermal neutron flux ratio is 106. Long-time irradiation (48 hours) was performed at reactor core periphery with thermal neutron flux of 3.34 x 10{sup 1}2 n/cm{sup 2}/s, and thermal to epithermal neutron flux ratio of 79. Activation by epithermal neutrons was taken into account for the (1/v) and resonance neutron absorption in both methods. A hyper pure germanium detection system was used for gamma-ray acquisitions. The concentration values of Al, Cr, Fe, Co, Cu, Zn, Se, Ag and Sb were estimated as percentages of the sample weight and compared with reported values. 1 tab.

  18. Calling behavior of mass-reared and wild Anastrepha serpentina (Diptera: Tephritidae).

    Science.gov (United States)

    Castrejón-Gómez, Victor R; Lascares, Shaila; Malo, Edi A; Toledo, Jorge; Rojas, Julio C

    2007-08-01

    The calling behavior of mass-reared and wild males of Anastrepha serpentina (Wiedemann) (Diptera: Tephritidae) was studied both in the laboratory and in field cage tests. In the laboratory, density (1, 5, and 10 males per container), age, and hour of day significantly affected calling behavior. Mass-reared males called independently of density, whereas wild males only called at densities of 5 and 10 individuals. Males of both strains started calling when they were 5-7 d old. The daily pattern of male calling was similar in both strains, starting at 0730 hours, and reaching a peak at 1330-1630 hours. Field cage tests showed that mass-reared males started calling when they were 5d old; the period of peak calling was when males were 8-9 d old. In contrast, wild males began calling when they were 10 d old, reaching peaks when males were 13, 15, and 18 d old. Wild males tended to form leks to call during each day of the experiment, whereas mass-reared males only formed leks during 2 d, both strains displaying very low levels. During field cage tests, males, independently of strain, displayed two calling peaks, one peak in the morning and one peak in the afternoon, whereas males observed in the laboratory only showed a single calling peak. The results are discussed in view of the effects of mass rearing A. serpentina males in relation to potential use of the sterile insect technique.

  19. Trace uranium analysis in geological sample by isotope dilution-alpha spectrometry and comparison with other techniques

    International Nuclear Information System (INIS)

    Shihomatsu, H.M.; Iyer, S.S.

    1988-12-01

    Establishment of uranium determination in geological samples by alpha spectrometric isotope dilution technique using 233 U tracer is described in the present work. The various steps involved in the method namely, preparation of the sample, electrodeposition, alpha spectrometry, isotope dilution, calculation of the concentration and error statistics are discussed in detail. The experimental parameters for the electrodeposition of uranium, like current density, pH concentration of the electrolyte solution, deposition time, electrode distance were all optimised based on the efficiency of the deposition. The total accuracy and precision of the IDAS using 233 U tracer in the determination of uranium in mineral and granite samples were of the order of 1 to 2% for the concentration range of 50-1500 ppm of U. Our results are compared with those obtained by others workers using similar and different techniques. (author) [pt

  20. The job demands-resources model of work engagement in South African call centres

    OpenAIRE

    Yolandi Janse van Rensburg; Billy Boonzaier; Michèle Boonzaier

    2013-01-01

    Orientation: A ‘sacrificial human resource strategy’ is practised in call centres, resulting in poor employee occupational health. Consequently, questions are posed in terms of the consequences of call centre work and which salient antecedent variables impact the engagement and wellbeing of call centre representatives. Research purpose: Firstly, to gauge the level of employee engagement amongst a sample of call centre representatives in South Africa and, secondly, to track the paths throu...

  1. Comparison of mobile and stationary spore-sampling techniques for estimating virulence frequencies in aerial barley powdery mildew populations

    DEFF Research Database (Denmark)

    Hovmøller, M.S.; Munk, L.; Østergård, Hanne

    1995-01-01

    Gene frequencies in samples of aerial populations of barley powdery mildew (Erysiphe graminis f.sp. hordei), which were collected in adjacent barley areas and in successive periods of time, were compared using mobile and stationary sampling techniques. Stationary samples were collected from trap ...

  2. Preparation of quality control samples for thyroid hormones T3 and T4 in radioimmunoassay techniques

    International Nuclear Information System (INIS)

    Ahmed, F.O.A.

    2006-03-01

    Today, the radioimmunoassay becomes one of the best techniques for quantitative analysis of very low concentration of different substances. RIA is being widely used in medical and research laboratories. To maintain high specificity and accuracy in RIA and other related techniques the quality controls must be introduced. In this dissertation quality control samples for thyroid hormones (Triiodothyronine T3 and Thyroxin T4), using RIA techniques. Ready made chinese T4, T3 RIA kits were used. IAEA statistical package were selected.(Author)

  3. Improved sample preparation and counting techniques for enhanced tritium measurement sensitivity

    Science.gov (United States)

    Moran, J.; Aalseth, C.; Bailey, V. L.; Mace, E. K.; Overman, C.; Seifert, A.; Wilcox Freeburg, E. D.

    2015-12-01

    Tritium (T) measurements offer insight to a wealth of environmental applications including hydrologic tracking, discerning ocean circulation patterns, and aging ice formations. However, the relatively short half-life of T (12.3 years) limits its effective age dating range. Compounding this limitation is the decrease in atmospheric T content by over two orders of magnitude (from 1000-2000 TU in 1962 to testing in the 1960's. We are developing sample preparation methods coupled to direct counting of T via ultra-low background proportional counters which, when combined, offer improved T measurement sensitivity (~4.5 mmoles of H2 equivalent) and will help expand the application of T age dating to smaller sample sizes linked to persistent environmental questions despite the limitations above. For instance, this approach can be used to T date ~ 2.2 mmoles of CH4 collected from sample-limited systems including microbial communities, soils, or subsurface aquifers and can be combined with radiocarbon dating to distinguish the methane's formation age from C age in a system. This approach can also expand investigations into soil organic C where the improved sensitivity will permit resolution of soil C into more descriptive fractions and provide direct assessments of the stability of specific classes of organic matter in soils environments. We are employing a multiple step sample preparation system whereby organic samples are first combusted with resulting CO2 and H2O being used as a feedstock to synthesize CH4. This CH4 is mixed with Ar and loaded directly into an ultra-low background proportional counter for measurement of T β decay in a shallow underground laboratory. Analysis of water samples requires only the addition of geologic CO2 feedstock with the sample for methane synthesis. The chemical nature of the preparation techniques enable high sample throughput with only the final measurement requiring T decay with total sample analysis time ranging from 2 -5 weeks

  4. Performance evaluation of an importance sampling technique in a Jackson network

    Science.gov (United States)

    brahim Mahdipour, E.; Masoud Rahmani, Amir; Setayeshi, Saeed

    2014-03-01

    Importance sampling is a technique that is commonly used to speed up Monte Carlo simulation of rare events. However, little is known regarding the design of efficient importance sampling algorithms in the context of queueing networks. The standard approach, which simulates the system using an a priori fixed change of measure suggested by large deviation analysis, has been shown to fail in even the simplest network settings. Estimating probabilities associated with rare events has been a topic of great importance in queueing theory, and in applied probability at large. In this article, we analyse the performance of an importance sampling estimator for a rare event probability in a Jackson network. This article carries out strict deadlines to a two-node Jackson network with feedback whose arrival and service rates are modulated by an exogenous finite state Markov process. We have estimated the probability of network blocking for various sets of parameters, and also the probability of missing the deadline of customers for different loads and deadlines. We have finally shown that the probability of total population overflow may be affected by various deadline values, service rates and arrival rates.

  5. The Relationship of On-Call Work with Fatigue, Work-Home Interference, and Perceived Performance Difficulties.

    Science.gov (United States)

    Ziebertz, Carla M; van Hooff, Madelon L M; Beckers, Debby G J; Hooftman, Wendela E; Kompier, Michiel A J; Geurts, Sabine A E

    2015-01-01

    This study examined the relationship between on-call duty exposure (active and total on-call hours a month, number of calls per duty) and employees' experiences of being on-call (stress due to unpredictability, ability to relax during inactive on-call periods, restrictions during on-call duties, on-call work demands, and satisfaction with compensation for on-call duties) on the one hand and fatigue, strain-based and time-based work-home interference (WHI), and perceived on-call performance difficulties (PPD) on the other hand. Cross-sectional survey data were collected among a large heterogeneous sample of Dutch employees (N = 5437). The final sample consisted of 157 on-call workers (23-69 years, 71% males). Data were analyzed by means of hierarchical regression analyses (controlling for age and job characteristics). Differences in on-call work exposure were not systematically related to fatigue, WHI, and PPD (all p's >0.50). The experience of being on-call explained a medium proportion of the variation in fatigue and strain-based WHI and a medium to large proportion of the variation in time-based WHI and PPD over and above the control variables. Our results suggest that it is employees' experience of being on-call, especially the experience of stress due to the unpredictability, rather than the amount of exposure, that is related to fatigue, WHI, and perceived on-call performance difficulties.

  6. The job demands-resources model of work engagement in South African call centres

    Directory of Open Access Journals (Sweden)

    Yolandi Janse van Rensburg

    2013-09-01

    Full Text Available Orientation: A ‘sacrificial human resource strategy’ is practised in call centres, resulting in poor employee occupational health. Consequently, questions are posed in terms of the consequences of call centre work and which salient antecedent variables impact the engagement and wellbeing of call centre representatives. Research purpose: Firstly, to gauge the level of employee engagement amongst a sample of call centre representatives in South Africa and, secondly, to track the paths through which salient personal and job resources affect this engagement. More specifically, the relationships between sense of coherence, leadership effectiveness, team effectiveness and engagement were investigated, thus testing the Job Demands-Resources model of work engagement. Motivation for the study: To present an application of the Job Demands-Resources model of work engagement in a call centre environment in order to diagnose current ills and consequently propose remedies. Research design: A cross-sectional survey design was used and a non-probability convenient sample of 217 call centre representatives was selected. The measuring instruments comprise the Utrecht Work Engagement Scale to measure engagement, the Team Diagnostic Survey to measure team effectiveness, the leadership practices inventory to gauge leadership effectiveness, and the Orientation to Life Questionnaire to measure sense of coherence. A series of structural equation modelling analyses were performed. Main findings: Contrary to the ‘electronic sweatshop’ image attached to call centre jobs depicted in the literature, results show a high level of employee engagement for call centre representatives in the sample. Also, personal resources such as sense of coherence and job resources such as team effectiveness related significantly to engagement. A non-significant relationship exists between leadership effectiveness and engagement. Practical/managerial implications: Both the content and

  7. The job demands-resources model of work engagement in South African call centres

    Directory of Open Access Journals (Sweden)

    Yolandi Janse van Rensburg

    2013-09-01

    Full Text Available Orientation: A ‘sacrificial human resource strategy’ is practised in call centres, resulting in poor employee occupational health. Consequently, questions are posed in terms of the consequences of call centre work and which salient antecedent variables impact the engagement and wellbeing of call centre representatives.Research purpose: Firstly, to gauge the level of employee engagement amongst a sample of call centre representatives in South Africa and, secondly, to track the paths through which salient personal and job resources affect this engagement. More specifically, the relationships between sense of coherence, leadership effectiveness, team effectiveness and engagement were investigated, thus testing the Job Demands-Resources model of work engagement.Motivation for the study: To present an application of the Job Demands-Resources model of work engagement in a call centre environment in order to diagnose current ills and consequently propose remedies.Research design: A cross-sectional survey design was used and a non-probability convenient sample of 217 call centre representatives was selected. The measuring instruments comprise the Utrecht Work Engagement Scale to measure engagement, the Team Diagnostic Survey to measure team effectiveness, the leadership practices inventory to gauge leadership effectiveness, and the Orientation to Life Questionnaire to measure sense of coherence. A series of structural equation modelling analyses were performed.Main findings: Contrary to the ‘electronic sweatshop’ image attached to call centre jobs depicted in the literature, results show a high level of employee engagement for call centre representatives in the sample. Also, personal resources such as sense of coherence and job resources such as team effectiveness related significantly to engagement. A non-significant relationship exists between leadership effectiveness and engagement.Practical/managerial implications: Both the content and

  8. Beyond simple small-angle X-ray scattering: developments in online complementary techniques and sample environments.

    Science.gov (United States)

    Bras, Wim; Koizumi, Satoshi; Terrill, Nicholas J

    2014-11-01

    Small- and wide-angle X-ray scattering (SAXS, WAXS) are standard tools in materials research. The simultaneous measurement of SAXS and WAXS data in time-resolved studies has gained popularity due to the complementary information obtained. Furthermore, the combination of these data with non X-ray based techniques, via either simultaneous or independent measurements, has advanced understanding of the driving forces that lead to the structures and morphologies of materials, which in turn give rise to their properties. The simultaneous measurement of different data regimes and types, using either X-rays or neutrons, and the desire to control parameters that initiate and control structural changes have led to greater demands on sample environments. Examples of developments in technique combinations and sample environment design are discussed, together with a brief speculation about promising future developments.

  9. Fluid approximation analysis of a call center model with time-varying arrivals and after-call work

    Directory of Open Access Journals (Sweden)

    Yosuke Kawai

    2015-12-01

    Full Text Available Important features to be included in queueing-theoretic models of the call center operation are multiple servers, impatient customers, time-varying arrival process, and operator’s after-call work (ACW. We propose a fluid approximation technique for the queueing model with these features by extending the analysis of a similar model without ACW recently developed by Liu and Whitt (2012. Our model assumes that the service for each quantum of fluid consists of a sequence of two stages, the first stage for the conversation with a customer and the second stage for the ACW. When the duration of each stage has exponential, hyperexponential or hypo-exponential distribution, we derive the time-dependent behavior of the content of fluid in each stage of service as well as that in the waiting room. Numerical examples are shown to illustrate the system performance for the cases in which the input rate and/or the number of servers vary in sinusoidal fashion as well as in adaptive ways and in stationary cases.

  10. Determination of trace elements in plant samples using XRF, PIXE and ICP-OES techniques

    International Nuclear Information System (INIS)

    Ahmed, Hassan Elzain Hassan

    2014-07-01

    The purpose of this study is to determine trace element concentration (Ca, Cu, Cr, K,Fe, Mn,Sr, and Za) in some sudanese wild plants namely, Ziziphus Abyssinica and Grewia Tenax. X-ray fluorescence ( X RF), particle-induced x-ray emission ( PIXE) and inductively coupled plasma-optical emission spectroscopy (ICP-OES) techniques were used for element determination. A series of plants standard references materials were used to check the reliability of the different employed techniques as well as to estimate possible factors for correcting the concentration of some elements that deviated significantly from their actual concentration. The results showed that, X RF, PIXE and ICP-OES are equally competitive methods for measuring Ca,K, Fe, Sr and Zn elements. Unlikely to ICP-OES seems to be superior techniques tend to be appropriate methods for Cu determination in plant samples however, for Mn element PIXE and ICP-OES are advisable techniques for measuring this element rather than X RF method. On the other hand, ICP-OES seems to be the superior techniques over PIXE and X RF methods for Cr and Ni determination in plant samples. The effect of geographical location on trace elements concentration in plants has been examined through determination of element in different species of Grewia Tenax than collected from different location. Most of measured elements showed similarity indicating there is no significant impact of locations on the difference of element contents. In addition, two plants with different genetic families namely, Ziziphus Spina Christi and Ziziphus Abyssinica were collected from the same location and screened for their trace element content. It was found that there were no difference between the two plants for Ca, K, Cu, Fe, and Sr element. However, significant variations were observed for Mn and Zn concentrations implying the possibility of using of those two elements for plant taxonomy purposes.(Author)

  11. Feasibility of self-sampled dried blood spot and saliva samples sent by mail in a population-based study.

    Science.gov (United States)

    Sakhi, Amrit Kaur; Bastani, Nasser Ezzatkhah; Ellingjord-Dale, Merete; Gundersen, Thomas Erik; Blomhoff, Rune; Ursin, Giske

    2015-04-11

    In large epidemiological studies it is often challenging to obtain biological samples. Self-sampling by study participants using dried blood spots (DBS) technique has been suggested to overcome this challenge. DBS is a type of biosampling where blood samples are obtained by a finger-prick lancet, blotted and dried on filter paper. However, the feasibility and efficacy of collecting DBS samples from study participants in large-scale epidemiological studies is not known. The aim of the present study was to test the feasibility and response rate of collecting self-sampled DBS and saliva samples in a population-based study of women above 50 years of age. We determined response proportions, number of phone calls to the study center with questions about sampling, and quality of the DBS. We recruited women through a study conducted within the Norwegian Breast Cancer Screening Program. Invitations, instructions and materials were sent to 4,597 women. The data collection took place over a 3 month period in the spring of 2009. Response proportions for the collection of DBS and saliva samples were 71.0% (3,263) and 70.9% (3,258), respectively. We received 312 phone calls (7% of the 4,597 women) with questions regarding sampling. Of the 3,263 individuals that returned DBS cards, 3,038 (93.1%) had been packaged and shipped according to instructions. A total of 3,032 DBS samples were sufficient for at least one biomarker analysis (i.e. 92.9% of DBS samples received by the laboratory). 2,418 (74.1%) of the DBS cards received by the laboratory were filled with blood according to the instructions (i.e. 10 completely filled spots with up to 7 punches per spot for up to 70 separate analyses). To assess the quality of the samples, we selected and measured two biomarkers (carotenoids and vitamin D). The biomarker levels were consistent with previous reports. Collecting self-sampled DBS and saliva samples through the postal services provides a low cost, effective and feasible

  12. 47 CFR 22.921 - 911 call processing procedures; 911-only calling mode.

    Science.gov (United States)

    2010-10-01

    ... programming in the mobile unit that determines the handling of a non-911 call and permit the call to be... CARRIER SERVICES PUBLIC MOBILE SERVICES Cellular Radiotelephone Service § 22.921 911 call processing procedures; 911-only calling mode. Mobile telephones manufactured after February 13, 2000 that are capable of...

  13. Sample application of sensitivity/uncertainty analysis techniques to a groundwater transport problem. National Low-Level Waste Management Program

    International Nuclear Information System (INIS)

    Seitz, R.R.; Rood, A.S.; Harris, G.A.; Maheras, S.J.; Kotecki, M.

    1991-06-01

    The primary objective of this document is to provide sample applications of selected sensitivity and uncertainty analysis techniques within the context of the radiological performance assessment process. These applications were drawn from the companion document Guidelines for Sensitivity and Uncertainty Analyses of Low-Level Radioactive Waste Performance Assessment Computer Codes (S. Maheras and M. Kotecki, DOE/LLW-100, 1990). Three techniques are illustrated in this document: one-factor-at-a-time (OFAT) analysis, fractional factorial design, and Latin hypercube sampling. The report also illustrates the differences in sensitivity and uncertainty analysis at the early and latter stages of the performance assessment process, and potential pitfalls that can be encountered when applying the techniques. The emphasis is on application of the techniques as opposed to the actual results, since the results are hypothetical and are not based on site-specific conditions

  14. Low-mass molecular dynamics simulation: A simple and generic technique to enhance configurational sampling

    Energy Technology Data Exchange (ETDEWEB)

    Pang, Yuan-Ping, E-mail: pang@mayo.edu

    2014-09-26

    Highlights: • Reducing atomic masses by 10-fold vastly improves sampling in MD simulations. • CLN025 folded in 4 of 10 × 0.5-μs MD simulations when masses were reduced by 10-fold. • CLN025 folded as early as 96.2 ns in 1 of the 4 simulations that captured folding. • CLN025 did not fold in 10 × 0.5-μs MD simulations when standard masses were used. • Low-mass MD simulation is a simple and generic sampling enhancement technique. - Abstract: CLN025 is one of the smallest fast-folding proteins. Until now it has not been reported that CLN025 can autonomously fold to its native conformation in a classical, all-atom, and isothermal–isobaric molecular dynamics (MD) simulation. This article reports the autonomous and repeated folding of CLN025 from a fully extended backbone conformation to its native conformation in explicit solvent in multiple 500-ns MD simulations at 277 K and 1 atm with the first folding event occurring as early as 66.1 ns. These simulations were accomplished by using AMBER forcefield derivatives with atomic masses reduced by 10-fold on Apple Mac Pros. By contrast, no folding event was observed when the simulations were repeated using the original AMBER forcefields of FF12SB and FF14SB. The results demonstrate that low-mass MD simulation is a simple and generic technique to enhance configurational sampling. This technique may propel autonomous folding of a wide range of miniature proteins in classical, all-atom, and isothermal–isobaric MD simulations performed on commodity computers—an important step forward in quantitative biology.

  15. Review of cleaning techniques and their effects on the chemical composition of foliar samples

    Energy Technology Data Exchange (ETDEWEB)

    Rossini Oliva, S.; Raitio, H.

    2003-07-01

    Chemical foliar analysis is a tool widely used to study tree nutrition and to monitor the impact and extent of air pollutants. This paper reviews a number of cleaning methods, and the effects of cleaning on foliar chemistry. Cleaning may include mechanical techniques such as the use of dry or moistened tissues, shaking, blowing, and brushing, or use various washing techniques with water or other solvents. Owing to the diversity of plant species, tissue differences, etc., there is no standard procedure for all kinds of samples. Analysis of uncleaned leaves is considered a good method for assessing the degree of air contamination because it provides an estimate of the element content of the deposits on leaf surfaces or when the analysis is aimed at the investigation of transfer of elements along the food chain. Sample cleaning is recommended in order (1) to investigate the transfer rate of chemical elements from soil to plants, (2) to qualify the washoff of dry deposition from foliage and (3) to separate superficially absorbed and biomass-incorporated elements. Since there is not a standard cleaning procedure for all kinds of samples and aims, it is advised to conduct a pilot study in order to be able to establish a cleaning procedure to provide reliable foliar data. (orig.)

  16. Detection of equine herpesvirus in horses with idiopathic keratoconjunctivitis and comparison of three sampling techniques.

    Science.gov (United States)

    Hollingsworth, Steven R; Pusterla, Nicola; Kass, Philip H; Good, Kathryn L; Brault, Stephanie A; Maggs, David J

    2015-09-01

    To determine the role of equine herpesvirus (EHV) in idiopathic keratoconjunctivitis in horses and to determine whether sample collection method affects detection of EHV DNA by quantitative polymerase chain reaction (qPCR). Twelve horses with idiopathic keratoconjunctivitis and six horses without signs of ophthalmic disease. Conjunctival swabs, corneal scrapings, and conjunctival biopsies were collected from 18 horses: 12 clinical cases with idiopathic keratoconjunctivitis and six euthanized controls. In horses with both eyes involved, the samples were taken from the eye judged to be more severely affected. Samples were tested with qPCR for EHV-1, EHV-2, EHV-4, and EHV-5 DNA. Quantity of EHV DNA and viral replicative activity were compared between the two populations and among the different sampling techniques; relative sensitivities of the sampling techniques were determined. Prevalence of EHV DNA as assessed by qPCR did not differ significantly between control horses and those with idiopathic keratoconjunctivitis. Sampling by conjunctival swab was more likely to yield viral DNA as assessed by qPCR than was conjunctival biopsy. EHV-1 and EHV-4 DNA were not detected in either normal or IKC-affected horses; EHV-2 DNA was detected in two of 12 affected horses but not in normal horses. EHV-5 DNA was commonly found in ophthalmically normal horses and horses with idiopathic keratoconjunctivitis. Because EHV-5 DNA was commonly found in control horses and in horses with idiopathic keratoconjunctivitis, qPCR was not useful for the etiological diagnosis of equine keratoconjunctivitis. Conjunctival swabs were significantly better at obtaining viral DNA samples than conjunctival biopsy in horses in which EHV-5 DNA was found. © 2015 American College of Veterinary Ophthalmologists.

  17. An anonymization technique using intersected decision trees

    Directory of Open Access Journals (Sweden)

    Sam Fletcher

    2015-07-01

    Full Text Available Data mining plays an important role in analyzing the massive amount of data collected in today’s world. However, due to the public’s rising awareness of privacy and lack of trust in organizations, suitable Privacy Preserving Data Mining (PPDM techniques have become vital. A PPDM technique provides individual privacy while allowing useful data mining. We present a novel noise addition technique called Forest Framework, two novel data quality evaluation techniques called EDUDS and EDUSC, and a security evaluation technique called SERS. Forest Framework builds a decision forest from a dataset and preserves all the patterns (logic rules of the forest while adding noise to the dataset. We compare Forest Framework to its predecessor, Framework, and another established technique, GADP. Our comparison is done using our three evaluation criteria, as well as Prediction Accuracy. Our experimental results demonstrate the success of our proposed extensions to Framework and the usefulness of our evaluation criteria.

  18. Beyond simple small-angle X-ray scattering: developments in online complementary techniques and sample environments

    Directory of Open Access Journals (Sweden)

    Wim Bras

    2014-11-01

    Full Text Available Small- and wide-angle X-ray scattering (SAXS, WAXS are standard tools in materials research. The simultaneous measurement of SAXS and WAXS data in time-resolved studies has gained popularity due to the complementary information obtained. Furthermore, the combination of these data with non X-ray based techniques, via either simultaneous or independent measurements, has advanced understanding of the driving forces that lead to the structures and morphologies of materials, which in turn give rise to their properties. The simultaneous measurement of different data regimes and types, using either X-rays or neutrons, and the desire to control parameters that initiate and control structural changes have led to greater demands on sample environments. Examples of developments in technique combinations and sample environment design are discussed, together with a brief speculation about promising future developments.

  19. Calling songs of some South African cicadas (Homoptera: Cicadidae)

    African Journals Online (AJOL)

    1987-07-13

    Jul 13, 1987 ... Figure 11 Posture of male cicadas during calling song, illustrated by a specimen ... parameters of the smaller samples falls within that of the largest conspecific ... under the control of the neuromuscular system (Pringle. 1954b).

  20. Low-Complexity Lossless and Near-Lossless Data Compression Technique for Multispectral Imagery

    Science.gov (United States)

    Xie, Hua; Klimesh, Matthew A.

    2009-01-01

    This work extends the lossless data compression technique described in Fast Lossless Compression of Multispectral- Image Data, (NPO-42517) NASA Tech Briefs, Vol. 30, No. 8 (August 2006), page 26. The original technique was extended to include a near-lossless compression option, allowing substantially smaller compressed file sizes when a small amount of distortion can be tolerated. Near-lossless compression is obtained by including a quantization step prior to encoding of prediction residuals. The original technique uses lossless predictive compression and is designed for use on multispectral imagery. A lossless predictive data compression algorithm compresses a digitized signal one sample at a time as follows: First, a sample value is predicted from previously encoded samples. The difference between the actual sample value and the prediction is called the prediction residual. The prediction residual is encoded into the compressed file. The decompressor can form the same predicted sample and can decode the prediction residual from the compressed file, and so can reconstruct the original sample. A lossless predictive compression algorithm can generally be converted to a near-lossless compression algorithm by quantizing the prediction residuals prior to encoding them. In this case, since the reconstructed sample values will not be identical to the original sample values, the encoder must determine the values that will be reconstructed and use these values for predicting later sample values. The technique described here uses this method, starting with the original technique, to allow near-lossless compression. The extension to allow near-lossless compression adds the ability to achieve much more compression when small amounts of distortion are tolerable, while retaining the low complexity and good overall compression effectiveness of the original algorithm.

  1. The Relationship of On-Call Work with Fatigue, Work-Home Interference, and Perceived Performance Difficulties

    Directory of Open Access Journals (Sweden)

    Carla M. Ziebertz

    2015-01-01

    Full Text Available Objectives. This study examined the relationship between on-call duty exposure (active and total on-call hours a month, number of calls per duty and employees’ experiences of being on-call (stress due to unpredictability, ability to relax during inactive on-call periods, restrictions during on-call duties, on-call work demands, and satisfaction with compensation for on-call duties on the one hand and fatigue, strain-based and time-based work-home interference (WHI, and perceived on-call performance difficulties (PPD on the other hand. Methods. Cross-sectional survey data were collected among a large heterogeneous sample of Dutch employees (N=5437. The final sample consisted of 157 on-call workers (23–69 years, 71% males. Data were analyzed by means of hierarchical regression analyses (controlling for age and job characteristics. Results. Differences in on-call work exposure were not systematically related to fatigue, WHI, and PPD (all p’s >0.50. The experience of being on-call explained a medium proportion of the variation in fatigue and strain-based WHI and a medium to large proportion of the variation in time-based WHI and PPD over and above the control variables. Conclusions. Our results suggest that it is employees’ experience of being on-call, especially the experience of stress due to the unpredictability, rather than the amount of exposure, that is related to fatigue, WHI, and perceived on-call performance difficulties.

  2. Determination of trace element contents in grass samples for cattle feeding using NAA techniques

    Energy Technology Data Exchange (ETDEWEB)

    Yusof, Alias Mohamad; Jagir Singh, Jasbir Kaur

    1987-09-01

    An investigation on trace elements contents in six types of grass samples used for cattle feeding have been carried out using NAA techniques. The grass samples, Mardi Digit, African Star, Signal, Guinea, Setaria and Setaria Splendida were found to contain at least 19 trace elements in varying concentrations. The results were compared to the figures obtained from available sources to ascertain the status as to whether the grass samples studied would satisfy the minimum requirements of trace elements present in grass for cattle feeding or otherwise. Preference made on the suitability of the grass samples for cattle feeding was based on the availability and abundance of the trace elements, taking into account factors such as the degree of toxicity, inadequate amounts and contamination due to the presence of other trace elements not essential for cattle feeding.

  3. Determination of trace element contents in grass samples for cattle feeding using NAA techniques

    International Nuclear Information System (INIS)

    Alias Mohamad Yusof; Jasbir Kaur Jagir Singh

    1987-01-01

    An investigation on trace elements contents in six types of grass samples used for cattle feeding have been carried out using NAA techniques. The grass samples, Mardi Digit, African Star, Signal, Guinea, Setaria and Setaria Splendida were found to contain at least 19 trace elements in varying concentrations. The results were compared to the figures obtained from available sources to ascertain the status as to whether the grass samples studied would satisfy the minimum requirements of trace elements present in grass for cattle feeding or otherwise. Preference made on the suitability of the grass samples for cattle feeding was based on the availability and abundance of the trace elements, taking into account factors such as the degree of toxicity, inadequate amounts and contamination due to the presence of other trace elements not essential for cattle feeding. (author)

  4. Trace uranium analysis in Indian coal samples using the fission track technique

    International Nuclear Information System (INIS)

    Jojo, P.J.; Rawat, A.; Kumar, Ashavani; Prasad, Rajendra

    1993-01-01

    The ever-growing demand for energy has resulted in the extensive use of fossil fuels, especially coal, for power generation. Coal and its by-products often contain significant amounts of radionuclides, including uranium, which is the ultimate source of the radioactive gas Radon-222. The present study gives the concentration of uranium in coal samples of different collieries in India, collected from various thermal power plants in the state of Uttar Pradesh. The estimates were made using the fission track technique. Latent damage tracks were not found to be uniformly distributed but showed sun bursts and clusters. Non-uniform distributions of trace elements are a very common phenomenon in rocks. The levels of uranium in the coal samples were found to vary from 2.0 to 4.9 ppm in uniform distributions and from 21.3 to 41.0 ppm in non-uniform distributions. Measurements were also made on fly ash samples where the average uranium concentration was found to be 8.4 and 49.3 ppm in uniform and non-uniform distributions, respectively. (author)

  5. Tracking urban human activity from mobile phone calling patterns.

    Science.gov (United States)

    Monsivais, Daniel; Ghosh, Asim; Bhattacharya, Kunal; Dunbar, Robin I M; Kaski, Kimmo

    2017-11-01

    Timings of human activities are marked by circadian clocks which in turn are entrained to different environmental signals. In an urban environment the presence of artificial lighting and various social cues tend to disrupt the natural entrainment with the sunlight. However, it is not completely understood to what extent this is the case. Here we exploit the large-scale data analysis techniques to study the mobile phone calling activity of people in large cities to infer the dynamics of urban daily rhythms. From the calling patterns of about 1,000,000 users spread over different cities but lying inside the same time-zone, we show that the onset and termination of the calling activity synchronizes with the east-west progression of the sun. We also find that the onset and termination of the calling activity of users follows a yearly dynamics, varying across seasons, and that its timings are entrained to solar midnight. Furthermore, we show that the average mid-sleep time of people living in urban areas depends on the age and gender of each cohort as a result of biological and social factors.

  6. Tracking urban human activity from mobile phone calling patterns.

    Directory of Open Access Journals (Sweden)

    Daniel Monsivais

    2017-11-01

    Full Text Available Timings of human activities are marked by circadian clocks which in turn are entrained to different environmental signals. In an urban environment the presence of artificial lighting and various social cues tend to disrupt the natural entrainment with the sunlight. However, it is not completely understood to what extent this is the case. Here we exploit the large-scale data analysis techniques to study the mobile phone calling activity of people in large cities to infer the dynamics of urban daily rhythms. From the calling patterns of about 1,000,000 users spread over different cities but lying inside the same time-zone, we show that the onset and termination of the calling activity synchronizes with the east-west progression of the sun. We also find that the onset and termination of the calling activity of users follows a yearly dynamics, varying across seasons, and that its timings are entrained to solar midnight. Furthermore, we show that the average mid-sleep time of people living in urban areas depends on the age and gender of each cohort as a result of biological and social factors.

  7. Callings, work role fit, psychological meaningfulness and work ...

    African Journals Online (AJOL)

    Our aim in this study was to investigate the relationships among a calling orientation, work role fit, psychological meaningfulness and work engagement of teachers in Zambia. A quantitative approach was followed and a cross-sectional survey was used. The sample (n = 150) included 75 basic and 75 secondary school ...

  8. Single-particle characterization of ice-nucleating particles and ice particles residuals sampled by three different techniques

    Science.gov (United States)

    Kandler, Konrad; Worringen, Annette; Benker, Nathalie; Dirsch, Thomas; Mertes, Stephan; Schenk, Ludwig; Kästner, Udo; Frank, Fabian; Nillius, Björn; Bundke, Ulrich; Rose, Diana; Curtius, Joachim; Kupiszewski, Piotr; Weingartner, Ernest; Vochezer, Paul; Schneider, Johannes; Schmidt, Susan; Weinbruch, Stephan; Ebert, Martin

    2015-04-01

    During January/February 2013, at the High Alpine Research Station Jungfraujoch a measurement campaign was carried out, which was centered on atmospheric ice-nucleating particles (INP) and ice particle residuals (IPR). Three different techniques for separation of INP and IPR from the non-ice-active particles are compared. The Ice Selective Inlet (ISI) and the Ice Counterflow Virtual Impactor (Ice-CVI) sample ice particles from mixed phase clouds and allow for the analysis of the residuals. The combination of the Fast Ice Nucleus Chamber (FINCH) and the Ice Nuclei Pumped Counterflow Virtual Impactor (IN-PCVI) provides ice-activating conditions to aerosol particles and extracts the activated INP for analysis. Collected particles were analyzed by scanning electron microscopy and energy-dispersive X-ray microanalysis to determine size, chemical composition and mixing state. All INP/IPR-separating techniques had considerable abundances (median 20 - 70 %) of instrumental contamination artifacts (ISI: Si-O spheres, probably calibration aerosol; Ice-CVI: Al-O particles; FINCH+IN-PCVI: steel particles). Also, potential sampling artifacts (e.g., pure soluble material) occurred with a median abundance of separated by all three techniques. Soot was a minor contributor. Lead was detected in less than 10 % of the particles, of which the majority were internal mixtures with other particle types. Sea-salt and sulfates were identified by all three methods as INP/IPR. Most samples showed a maximum of the INP/IPR size distribution at 400 nm geometric diameter. In a few cases, a second super-micron maximum was identified. Soot/carbonaceous material and metal oxides were present mainly in the submicron range. ISI and FINCH yielded silicates and Ca-rich particles mainly with diameters above 1 µm, while the Ice-CVI also separated many submicron IPR. As strictly parallel sampling could not be performed, a part of the discrepancies between the different techniques may result from

  9. Extraction of Plutonium From Spiked INEEL Soil Samples Using the Ligand-Assisted Supercritical Fluid Extraction (LA-SFE) Technique

    International Nuclear Information System (INIS)

    Fox, R.V.; Mincher, B.J.; Holmes, R.G.G.

    1999-01-01

    In order to investigate the effectiveness of ligand-assisted supercritical fluid extraction for the removal of transuranic contaminations from soils an Idaho National Engineering and Environmental Laboratory (INEEL) silty-clay soil sample was obtained from near the Radioactive Waste Management Complex area and subjected to three different chemical preparations before being spiked with plutonium. The spiked INEEL soil samples were subjected to a sequential aqueous extraction procedure to determine radionuclide portioning in each sample. Results from those extractions demonstrate that plutonium consistently partitioned into the residual fraction across all three INEEL soil preparations whereas americium partitioned 73% into the iron/manganese fraction for soil preparation A, with the balance partitioning into the residual fraction. Plutonium and americium were extracted from the INEEL soil samples using a ligand-assisted supercritical fluid extraction technique. Initial supercritical fluid extraction runs produced plutonium extraction technique. Initial supercritical fluid extraction runs produced plutonium extraction efficiencies ranging from 14% to 19%. After a second round wherein the initial extraction parameters were changed, the plutonium extraction efficiencies increased to 60% and as high as 80% with the americium level in the post-extracted soil samples dropping near to the detection limits. The third round of experiments are currently underway. These results demonstrate that the ligand-assisted supercritical fluid extraction technique can effectively extract plutonium from the spiked INEEL soil preparations

  10. Instrument calls and real-time code for laboratory automation

    International Nuclear Information System (INIS)

    Taber, L.; Ames, H.S.; Yamauchi, R.K.; Barton, G.W. Jr.

    1978-01-01

    These programs are the result of a joint Lawrence Livermore Laboratory and Environmental Protection Agency project to automate water quality laboratories. They form the interface between the analytical instruments and the BASIC language programs for data reduction and analysis. They operate on Data General NOVA 840's at Cincinnati and Chicago and on a Data General ECLIPSE C330 at Livermore. The operating system consists of unmodified RDOS, Data General's disk operating system, and Data General's multiuser BASIC modified to provide the instrument CALLs and other functions described. Instruments automated at various laboratories include Technicon AutoAnalyzers, atomic absorption spectrophotometers, total organic carbon analyzers, an emission spectrometer, an electronic balance, sample changers, and an optical spectrophotometer. Other instruments may be automated using these same CALLs, or new CALLs may be written as described

  11. A novel in-situ sampling and VFA sensor technique for anaerobic systems

    DEFF Research Database (Denmark)

    Pind, Peter Frode; Angelidaki, Irini; Ahring, Birgitte Kiær

    2002-01-01

    A key information for understanding and controlling the anaerobic biogas process is the concentration of Volatile Fatty Acids (VFA). However, access to this information has so far been limited to off-line measurements by manual time and labour consuming methods. We have developed a new technique ...... than 1000 samples on both a fullscale biogas plant and lab-scale reactors. The measuring range covers specific measurements of acetate, propionate, iso-/n-butyrate and iso-/n-valerate from 0.1 to 50 mM (6–3,000 mg)....

  12. [Work-family conflict in call center].

    Science.gov (United States)

    Ghislieri, Chiara; Ricotta, Simona; Colombo, Lara

    2012-01-01

    The working environment of call centers, which have seen a significant growth in recent years, has been the subject of several studies aiming at understanding its specific dynamics, with particular attention to the possible causes of stress and discomfort. Despite the fact that the work-family conflict is considered a source of stress responsible for undermining workers' well-being, and as such has been explored in many work environments, there is still very little research specific to call centers. This study had the following aims: to explore work-family conflict perceived by call-center operators taking account of any differences related to respondents'professional and personal characteristics; to understand which demands and resources can have an impact on work-family conflict in this context. The study was carried out on a sample of 898 call center operators in a telecommunications company through the administration of a self-reporting questionnaire. Data analysis included: t-test, one-way analysis of variance, linear correlations and multiple regressions. A higher perception of work-family conflict among workers having a full-time contract was observed compared to those having part-time contracts. Multiple regression analysis identified as sources of influence on work-family conflict: emotional dissonance, uneasiness due customer dissatisfaction, workload, avoidance coping and working hours. Work-family conflict in the context studied is not particularly critical: it is in part influenced by professional and personal characteristics of respondents and primarily caused by work demands. Managerial implications are discussed, especially referred to training activities.

  13. An Electromagnetic Gauge Technique for Measuring Shocked Particle Velocity in Electrically Conductive Samples

    Science.gov (United States)

    Cheng, David; Yoshinaka, Akio

    2014-11-01

    Electromagnetic velocity (EMV) gauges are a class of film gauges which permit the direct in-situ measurement of shocked material flow velocity. The active sensing element, typically a metallic foil, requires exposure to a known external magnetic field in order to produce motional electromotive force (emf). Due to signal distortion caused by mutual inductance between sample and EMV gauge, this technique is typically limited to shock waves in non-conductive materials. In conductive samples, motional emf generated in the EMV gauge has to be extracted from the measured signal which results from the combined effects of both motional emf and voltage changes from induced currents. An electromagnetic technique is presented which analytically models the dynamics of induced current between a copper disk moving as a rigid body with constant 1D translational velocity toward an EMV gauge, where both disk and gauge are exposed to a uniform external static magnetic field. The disk is modelled as a magnetic dipole loop where its Foucault current is evaluated from the characteristics of the fields, whereas the EMV gauge is modelled as a circuit loop immersed in the field of the magnetic dipole loop, the intensity of which is calculated as a function of space and, implicitly, time. Equations of mutual induction are derived and the current induced in the EMV gauge loop is solved, allowing discrimination of the motional emf. Numerical analysis is provided for the step response of the induced EMV gauge current with respect to the Foucault current in the moving copper sample.

  14. Active sampling technique to enhance chemical signature of buried explosives

    Science.gov (United States)

    Lovell, John S.; French, Patrick D.

    2004-09-01

    Deminers and dismounted countermine engineers commonly use metal detectors, ground penetrating radar and probes to locate mines. Many modern landmines have a very low metal content, which severely limits the effectiveness of metal detectors. Canines have also been used for landmine detection for decades. Experiments have shown that canines smell the explosives which are known to leak from most types of landmines. The fact that dogs can detect landmines indicates that vapor sensing is a viable approach to landmine detection. Several groups are currently developing systems to detect landmines by "sniffing" for the ultra-trace explosive vapors above the soil. The amount of material that is available to passive vapor sensing systems is limited to no more than the vapor in equilibrium with the explosive related chemicals (ERCs) distributed in the surface soils over and near the landmine. The low equilibrium vapor pressure of TNT in the soil/atmosphere boundary layer and the limited volume of the boundary layer air imply that passive chemical vapor sensing systems require sensitivities in the picogram range, or lower. ADA is working to overcome many of the limitations of passive sampling methods, by the use of an active sampling method that employs a high-powered (1,200+ joules) strobe lamp to create a highly amplified plume of vapor and/or ERC-bearing fine particulates. Initial investigations have demonstrated that this approach can amplify the detectability of TNT by two or three orders of magnitude. This new active sampling technique could be used with any suitable explosive sensor.

  15. Calling, Vocational Development, and Well Being: A Longitudinal Study of Medical Students

    Science.gov (United States)

    Duffy, Ryan D.; Manuel, R. Stephen; Borges, Nicole J.; Bott, Elizabeth M.

    2011-01-01

    The present study investigated the relation of calling to the vocational development and well-being of a sample of medical students. Students were surveyed at two time points: prior to beginning the first year of medical school and prior to beginning the third year of medical school. At each time point, calling moderately correlated with positive…

  16. Determination of multi-element in marine sediment samples collected in Angola by the k0-NAA technique

    International Nuclear Information System (INIS)

    Teixeira, M.C.P.; Ho Manh Dung; Cao Dong Vu; Nguyen Thi Sy; Nguyen Thanh Binh; Vuong Huu Tan

    2006-01-01

    The marine sediment samples were designed to collect in Angola for marine environmental pollution study. The k 0 -standardization method of neutron activation analysis (k 0 -NAA) on Dalat research reactor has been developed to determine of multi-element in the Angola marine sediment samples. The samples were irradiated in cell 7-1 for short- and middle-lived nuclides and rotary specimen rack for long-lived nuclides. The irradiation facilities were characterized for neutron spectrum parameters and post-activated samples were measured on the calibrated gamma-ray spectrometers using HPGe detectors. The analytical results for 9 marine sediment samples with 27 elements: Al, As, Br, Ca, Ce,Cl, Co, Cs, Dy, Fe, Hf, I, K, Mg, Mn, Na, Rb, Sb, Sc, Se, Sm, Th, Ti, U, V and Zn in term of mean concentration, standard deviation and their content range are shown in the report. The analytical quality assurance was done by analysis of a Japan's certified reference material namely marine sediment NMIJ-CRM-7302a. These preliminary results revealed that the k 0 -NAA technique on the Dalat research reactor is a good analytical technique for determination of multi-element in the marine sediment samples. Some heavy metals and trace elements determined in this work possibly connected to the human activities at the sampling region. (author)

  17. Characterization of Some Iraqi Archaeological Samples Using IBA, Analytical X-ray and Other Complementary Techniques

    International Nuclear Information System (INIS)

    Al-Sarraj, Ziyad Shihab; Damboos, Hassan I; Roumie, Mohamad

    2012-01-01

    The present work aimed at investigating the compositions and microstructures of some archaeological samples which dated back to various periods of the ancient Iraqi civilizations using PIXE, XRF, XRD, and SEM techniques. The models selected for the study (ceramics, glaze, etc.) were diverse in size and nature, therefore a limited number of samples were then butted from them by a small diamond wheel. Conventional powder metallurgy method was then used to prepare the samples. Dried samples were then coated with a thin layer of carbon, and analyzed using the ion beam accelerator of the LAEC. Three other groups of samples were also prepared for the purpose of analysis by X-ray fluorescence (XRF), X-ray diffraction (XRD), and scanning electron microscope (SEM). Analysis results of the chemical composition showed good agreement between the various techniques as well as for phases, while the fine structure analysis obtained by optical and scanning microscopy exhibited features of a structure where it got an intensified densification in the final stage of sintering and accompanied by quasi-homogeneous distribution of the closed pores. This will lead to the conclusion that the temperature used for sintering by ancient Iraqi was sufficient and it may fall in the range between 950-1200°C, also the mixes and the forming methods used by them, were both suitable to obtain good sintered bodies with even distribution of pores. A ring-shaped trace noticed in SEM micrographs need more work and study to explain what it is?

  18. Analysis of soil samples from Gebeng area using NAA technique

    Science.gov (United States)

    Elias, Md Suhaimi; Wo, Yii Mei; Hamzah, Mohd Suhaimi; Shukor, Shakirah Abd; Rahman, Shamsiah Ab; Salim, Nazaratul Ashifa Abdullah; Azman, Muhamad Azfar; Hashim, Azian

    2017-01-01

    Rapid development and urbanization will increase number of residence and industrial area. Without proper management and control of pollution, these will give an adverse effect to environment and human life. The objective of this study to identify and quantify key contaminants into the environment of the Gebeng area as a result of industrial and human activities. Gebeng area was gazetted as one of the industrial estate in Pahang state. Assessment of elemental pollution in soil of Gebeng area base on level of concentration, enrichment factor and geo-accumulation index. The enrichment factors (EFs) were determined by the elemental rationing method, whilst the geo-accumulation index (Igeo) by comparing of current to continental crustal average concentration of element. Twenty-seven of soil samples were collected from Gebeng area. Soil samples were analysed by using Neutron Activation Analyses (NAA) technique. The obtained data showed higher concentration of iron (Fe) due to abundance in soil compared to other elements. The results of enrichment factor showed that Gebeng area have enrich with elements of As, Br, Hf, Sb, Th and U. Base on the geo-accumulation index (Igeo) classification, the soil quality of Gebeng area can be classified as class 0, (uncontaminated) to Class 3, (moderately to heavily contaminated).

  19. Advances in modern sample preparation techniques using microwaves assisted chemistry for metal species determination (W1)

    International Nuclear Information System (INIS)

    Ponard, O.F.X.

    2002-01-01

    Full text: Sample preparation has long been the bottleneck of environmental analysis for both total and species specific analysis. Digestion, extraction and preparation of the analytes are relying on a series of chemical reactions. The introduction of microwave assisted sample preparation has first been viewed as a mean to accelerate the kinetics of digestion of the matrix for total elements and fast samples preparation procedures. However, the extensive development and success of microwave digestion procedures in total elemental analysis has now allowed to have a larger insight of the perspectives offered by this technique. Microwave technologies now offer to have a precise control of the temperature and indirectly control the reaction kinetics taking place during the sample preparation procedures. Microwave assisted chemistry permits to perform simultaneously the fundamental steps required for metal species extraction and derivatization. The number of sample preparation steps used for organotin or organomercury species have been reduced to one and the total time of sample preparation brought down for a few hours to some minutes. Further, the developments of GC/ICP/MS techniques allow to routinely use speciated isotopic dilution methods has internal probe of the chemical reactions. These new approaches allow us to use the addition of the labeled species for isotopic dilution as a mean to evaluate and follow the chemical processes taking place during the extraction procedure. These procedures will help us to understand and check for the stability of the analytes during the chemistry of the sample preparation procedure and bring some insights of the chemistry taking place during the extraction. Understanding the different mechanisms involved in the sample preparation steps will allow us in return to further improve all theses procedures and bring us to the horizon of 'on-line sample preparation and detection'. (author)

  20. Reconstructing the temporal ordering of biological samples using microarray data.

    Science.gov (United States)

    Magwene, Paul M; Lizardi, Paul; Kim, Junhyong

    2003-05-01

    Accurate time series for biological processes are difficult to estimate due to problems of synchronization, temporal sampling and rate heterogeneity. Methods are needed that can utilize multi-dimensional data, such as those resulting from DNA microarray experiments, in order to reconstruct time series from unordered or poorly ordered sets of observations. We present a set of algorithms for estimating temporal orderings from unordered sets of sample elements. The techniques we describe are based on modifications of a minimum-spanning tree calculated from a weighted, undirected graph. We demonstrate the efficacy of our approach by applying these techniques to an artificial data set as well as several gene expression data sets derived from DNA microarray experiments. In addition to estimating orderings, the techniques we describe also provide useful heuristics for assessing relevant properties of sample datasets such as noise and sampling intensity, and we show how a data structure called a PQ-tree can be used to represent uncertainty in a reconstructed ordering. Academic implementations of the ordering algorithms are available as source code (in the programming language Python) on our web site, along with documentation on their use. The artificial 'jelly roll' data set upon which the algorithm was tested is also available from this web site. The publicly available gene expression data may be found at http://genome-www.stanford.edu/cellcycle/ and http://caulobacter.stanford.edu/CellCycle/.

  1. Sub-sampling-based 2D localization of an impulsive acoustic source in reverberant environments

    KAUST Repository

    Omer, Muhammad

    2014-07-01

    This paper presents a robust method for two-dimensional (2D) impulsive acoustic source localization in a room environment using low sampling rates. The proposed method finds the time delay from the room impulse response (RIR) which makes it robust against room reverberations. We consider the RIR as a sparse phenomenon and apply a recently proposed sparse signal reconstruction technique called orthogonal clustering (OC) for its estimation from the sub-sampled received signal. The arrival time of the direct path signal at a pair of microphones is identified from the estimated RIR, and their difference yields the desired time delay estimate (TDE). Low sampling rates reduces the hardware and computational complexity and decreases the communication between the microphones and the centralized location. Simulation and experimental results of an actual hardware setup are presented to demonstrate the performance of the proposed technique.

  2. Sub-sampling-based 2D localization of an impulsive acoustic source in reverberant environments

    KAUST Repository

    Omer, Muhammad; Quadeer, Ahmed A; Sharawi, Mohammad S; Al-Naffouri, Tareq Y.

    2014-01-01

    This paper presents a robust method for two-dimensional (2D) impulsive acoustic source localization in a room environment using low sampling rates. The proposed method finds the time delay from the room impulse response (RIR) which makes it robust against room reverberations. We consider the RIR as a sparse phenomenon and apply a recently proposed sparse signal reconstruction technique called orthogonal clustering (OC) for its estimation from the sub-sampled received signal. The arrival time of the direct path signal at a pair of microphones is identified from the estimated RIR, and their difference yields the desired time delay estimate (TDE). Low sampling rates reduces the hardware and computational complexity and decreases the communication between the microphones and the centralized location. Simulation and experimental results of an actual hardware setup are presented to demonstrate the performance of the proposed technique.

  3. Somatic point mutation calling in low cellularity tumors.

    Directory of Open Access Journals (Sweden)

    Karin S Kassahn

    Full Text Available Somatic mutation calling from next-generation sequencing data remains a challenge due to the difficulties of distinguishing true somatic events from artifacts arising from PCR, sequencing errors or mis-mapping. Tumor cellularity or purity, sub-clonality and copy number changes also confound the identification of true somatic events against a background of germline variants. We have developed a heuristic strategy and software (http://www.qcmg.org/bioinformatics/qsnp/ for somatic mutation calling in samples with low tumor content and we show the superior sensitivity and precision of our approach using a previously sequenced cell line, a series of tumor/normal admixtures, and 3,253 putative somatic SNVs verified on an orthogonal platform.

  4. A cost-saving statistically based screening technique for focused sampling of a lead-contaminated site

    International Nuclear Information System (INIS)

    Moscati, A.F. Jr.; Hediger, E.M.; Rupp, M.J.

    1986-01-01

    High concentrations of lead in soils along an abandoned railroad line prompted a remedial investigation to characterize the extent of contamination across a 7-acre site. Contamination was thought to be spotty across the site reflecting its past use in battery recycling operations at discrete locations. A screening technique was employed to delineate the more highly contaminated areas by testing a statistically determined minimum number of random samples from each of seven discrete site areas. The approach not only quickly identified those site areas which would require more extensive grid sampling, but also provided a statistically defensible basis for excluding other site areas from further consideration, thus saving the cost of additional sample collection and analysis. The reduction in the number of samples collected in ''clean'' areas of the site ranged from 45 to 60%

  5. Large Sample Neutron Activation Analysis of Heterogeneous Samples

    International Nuclear Information System (INIS)

    Stamatelatos, I.E.; Vasilopoulou, T.; Tzika, F.

    2018-01-01

    A Large Sample Neutron Activation Analysis (LSNAA) technique was developed for non-destructive analysis of heterogeneous bulk samples. The technique incorporated collimated scanning and combining experimental measurements and Monte Carlo simulations for the identification of inhomogeneities in large volume samples and the correction of their effect on the interpretation of gamma-spectrometry data. Corrections were applied for the effect of neutron self-shielding, gamma-ray attenuation, geometrical factor and heterogeneous activity distribution within the sample. A benchmark experiment was performed to investigate the effect of heterogeneity on the accuracy of LSNAA. Moreover, a ceramic vase was analyzed as a whole demonstrating the feasibility of the technique. The LSNAA results were compared against results obtained by INAA and a satisfactory agreement between the two methods was observed. This study showed that LSNAA is a technique capable to perform accurate non-destructive, multi-elemental compositional analysis of heterogeneous objects. It also revealed the great potential of the technique for the analysis of precious objects and artefacts that need to be preserved intact and cannot be damaged for sampling purposes. (author)

  6. Single-particle characterization of ice-nucleating particles and ice particle residuals sampled by three different techniques

    Science.gov (United States)

    Worringen, A.; Kandler, K.; Benker, N.; Dirsch, T.; Mertes, S.; Schenk, L.; Kästner, U.; Frank, F.; Nillius, B.; Bundke, U.; Rose, D.; Curtius, J.; Kupiszewski, P.; Weingartner, E.; Vochezer, P.; Schneider, J.; Schmidt, S.; Weinbruch, S.; Ebert, M.

    2015-04-01

    In the present work, three different techniques to separate ice-nucleating particles (INPs) as well as ice particle residuals (IPRs) from non-ice-active particles are compared. The Ice Selective Inlet (ISI) and the Ice Counterflow Virtual Impactor (Ice-CVI) sample ice particles from mixed-phase clouds and allow after evaporation in the instrument for the analysis of the residuals. The Fast Ice Nucleus Chamber (FINCH) coupled with the Ice Nuclei Pumped Counterflow Virtual Impactor (IN-PCVI) provides ice-activating conditions to aerosol particles and extracts the activated particles for analysis. The instruments were run during a joint field campaign which took place in January and February 2013 at the High Alpine Research Station Jungfraujoch (Switzerland). INPs and IPRs were analyzed offline by scanning electron microscopy and energy-dispersive X-ray microanalysis to determine their size, chemical composition and mixing state. Online analysis of the size and chemical composition of INP activated in FINCH was performed by laser ablation mass spectrometry. With all three INP/IPR separation techniques high abundances (median 20-70%) of instrumental contamination artifacts were observed (ISI: Si-O spheres, probably calibration aerosol; Ice-CVI: Al-O particles; FINCH + IN-PCVI: steel particles). After removal of the instrumental contamination particles, silicates, Ca-rich particles, carbonaceous material and metal oxides were the major INP/IPR particle types obtained by all three techniques. In addition, considerable amounts (median abundance mostly a few percent) of soluble material (e.g., sea salt, sulfates) were observed. As these soluble particles are often not expected to act as INP/IPR, we consider them as potential measurement artifacts. Minor types of INP/IPR include soot and Pb-bearing particles. The Pb-bearing particles are mainly present as an internal mixture with other particle types. Most samples showed a maximum of the INP/IPR size distribution at 200

  7. Microwave Heating of Synthetic Skin Samples for Potential Treatment of Gout Using the Metal-Assisted and Microwave-Accelerated Decrystallization Technique.

    Science.gov (United States)

    Toker, Salih; Boone-Kukoyi, Zainab; Thompson, Nishone; Ajifa, Hillary; Clement, Travis; Ozturk, Birol; Aslan, Kadir

    2016-11-30

    Physical stability of synthetic skin samples during their exposure to microwave heating was investigated to demonstrate the use of the metal-assisted and microwave-accelerated decrystallization (MAMAD) technique for potential biomedical applications. In this regard, optical microscopy and temperature measurements were employed for the qualitative and quantitative assessment of damage to synthetic skin samples during 20 s intermittent microwave heating using a monomode microwave source (at 8 GHz, 2-20 W) up to 120 s. The extent of damage to synthetic skin samples, assessed by the change in the surface area of skin samples, was negligible for microwave power of ≤7 W and more extensive damage (>50%) to skin samples occurred when exposed to >7 W at initial temperature range of 20-39 °C. The initial temperature of synthetic skin samples significantly affected the extent of change in temperature of synthetic skin samples during their exposure to microwave heating. The proof of principle use of the MAMAD technique was demonstrated for the decrystallization of a model biological crystal (l-alanine) placed under synthetic skin samples in the presence of gold nanoparticles. Our results showed that the size (initial size ∼850 μm) of l-alanine crystals can be reduced up to 60% in 120 s without damage to synthetic skin samples using the MAMAD technique. Finite-difference time-domain-based simulations of the electric field distribution of an 8 GHz monomode microwave radiation showed that synthetic skin samples are predicted to absorb ∼92.2% of the microwave radiation.

  8. Microwave Heating of Synthetic Skin Samples for Potential Treatment of Gout Using the Metal-Assisted and Microwave-Accelerated Decrystallization Technique

    Science.gov (United States)

    2016-01-01

    Physical stability of synthetic skin samples during their exposure to microwave heating was investigated to demonstrate the use of the metal-assisted and microwave-accelerated decrystallization (MAMAD) technique for potential biomedical applications. In this regard, optical microscopy and temperature measurements were employed for the qualitative and quantitative assessment of damage to synthetic skin samples during 20 s intermittent microwave heating using a monomode microwave source (at 8 GHz, 2–20 W) up to 120 s. The extent of damage to synthetic skin samples, assessed by the change in the surface area of skin samples, was negligible for microwave power of ≤7 W and more extensive damage (>50%) to skin samples occurred when exposed to >7 W at initial temperature range of 20–39 °C. The initial temperature of synthetic skin samples significantly affected the extent of change in temperature of synthetic skin samples during their exposure to microwave heating. The proof of principle use of the MAMAD technique was demonstrated for the decrystallization of a model biological crystal (l-alanine) placed under synthetic skin samples in the presence of gold nanoparticles. Our results showed that the size (initial size ∼850 μm) of l-alanine crystals can be reduced up to 60% in 120 s without damage to synthetic skin samples using the MAMAD technique. Finite-difference time-domain-based simulations of the electric field distribution of an 8 GHz monomode microwave radiation showed that synthetic skin samples are predicted to absorb ∼92.2% of the microwave radiation. PMID:27917407

  9. A comparative study of 232Th and 238U activity estimation in soil samples by gamma spectrometry and neutron activation analysis technique

    International Nuclear Information System (INIS)

    Anilkumar, Rekha; Anilkumar, S.; Narayani, K.; Babu, D.A.R.; Sharma, D.N.

    2012-01-01

    Neutron activation analysis (NAA) is a well-established analytical technique. It has many advantages as compared to the other commonly used techniques. NAA can be performed in a variety of ways depending on the element, its activity level in the sample, interference from the sample matrix and other elements, etc. This technique is used to get high analytical sensitivity and low detection limits (ppm to ppb). The high sensitivity is due to the irradiation at high neutron flux available from the research reactors and the activity measurement is done using high resolution HPGe detectors. In this paper, the activity estimation of soil samples using neutron activation and direct gamma spectrometry methods are compared. Even though the weights of samples considered and samples preparation methods are different for these two methods, the estimated activity values are comparable. (author)

  10. Detection, characterization and quantification of inorganic engineered nanomaterials: A review of techniques and methodological approaches for the analysis of complex samples

    Energy Technology Data Exchange (ETDEWEB)

    Laborda, Francisco, E-mail: flaborda@unizar.es; Bolea, Eduardo; Cepriá, Gemma; Gómez, María T.; Jiménez, María S.; Pérez-Arantegui, Josefina; Castillo, Juan R.

    2016-01-21

    The increasing demand of analytical information related to inorganic engineered nanomaterials requires the adaptation of existing techniques and methods, or the development of new ones. The challenge for the analytical sciences has been to consider the nanoparticles as a new sort of analytes, involving both chemical (composition, mass and number concentration) and physical information (e.g. size, shape, aggregation). Moreover, information about the species derived from the nanoparticles themselves and their transformations must also be supplied. Whereas techniques commonly used for nanoparticle characterization, such as light scattering techniques, show serious limitations when applied to complex samples, other well-established techniques, like electron microscopy and atomic spectrometry, can provide useful information in most cases. Furthermore, separation techniques, including flow field flow fractionation, capillary electrophoresis and hydrodynamic chromatography, are moving to the nano domain, mostly hyphenated to inductively coupled plasma mass spectrometry as element specific detector. Emerging techniques based on the detection of single nanoparticles by using ICP-MS, but also coulometry, are in their way to gain a position. Chemical sensors selective to nanoparticles are in their early stages, but they are very promising considering their portability and simplicity. Although the field is in continuous evolution, at this moment it is moving from proofs-of-concept in simple matrices to methods dealing with matrices of higher complexity and relevant analyte concentrations. To achieve this goal, sample preparation methods are essential to manage such complex situations. Apart from size fractionation methods, matrix digestion, extraction and concentration methods capable of preserving the nature of the nanoparticles are being developed. This review presents and discusses the state-of-the-art analytical techniques and sample preparation methods suitable for

  11. Detection, characterization and quantification of inorganic engineered nanomaterials: A review of techniques and methodological approaches for the analysis of complex samples

    International Nuclear Information System (INIS)

    Laborda, Francisco; Bolea, Eduardo; Cepriá, Gemma; Gómez, María T.; Jiménez, María S.; Pérez-Arantegui, Josefina; Castillo, Juan R.

    2016-01-01

    The increasing demand of analytical information related to inorganic engineered nanomaterials requires the adaptation of existing techniques and methods, or the development of new ones. The challenge for the analytical sciences has been to consider the nanoparticles as a new sort of analytes, involving both chemical (composition, mass and number concentration) and physical information (e.g. size, shape, aggregation). Moreover, information about the species derived from the nanoparticles themselves and their transformations must also be supplied. Whereas techniques commonly used for nanoparticle characterization, such as light scattering techniques, show serious limitations when applied to complex samples, other well-established techniques, like electron microscopy and atomic spectrometry, can provide useful information in most cases. Furthermore, separation techniques, including flow field flow fractionation, capillary electrophoresis and hydrodynamic chromatography, are moving to the nano domain, mostly hyphenated to inductively coupled plasma mass spectrometry as element specific detector. Emerging techniques based on the detection of single nanoparticles by using ICP-MS, but also coulometry, are in their way to gain a position. Chemical sensors selective to nanoparticles are in their early stages, but they are very promising considering their portability and simplicity. Although the field is in continuous evolution, at this moment it is moving from proofs-of-concept in simple matrices to methods dealing with matrices of higher complexity and relevant analyte concentrations. To achieve this goal, sample preparation methods are essential to manage such complex situations. Apart from size fractionation methods, matrix digestion, extraction and concentration methods capable of preserving the nature of the nanoparticles are being developed. This review presents and discusses the state-of-the-art analytical techniques and sample preparation methods suitable for

  12. Training Opportunities and Employee Exhaustion in Call Centres: Mediation by Psychological Contract Fulfilment

    Science.gov (United States)

    Chambel, Maria Jose; Castanheira, Filipa

    2012-01-01

    The aim of this study is to analyse psychological contract fulfilment as a mechanism through which training affects stress in call centres. The hypotheses were tested on a sample of 412 call centre operators, using structural equation modelling to analyse their survey responses. Our results demonstrated that training is negatively related to…

  13. Nuclear techniques for trace element analysis. PIXE and its applications to biomedical samples

    International Nuclear Information System (INIS)

    Cata-Danil, I.; Moro, R.; Gialanella, G.

    1996-01-01

    Problems in understanding the role of trace elements in the functioning of life processes are discussed. A brief review of the state of the PIXE technique is given. Principles and recent advances in beam systems, instrumentation and sample handling are covered. A rather comprehensive list of references regarding varies methodological aspects and biomedical applications is given. Some applications are discussed. In particular, preliminary results of an investigation regarding pediatric obesity are presented. (author) 5 tabs., 21 refs

  14. Determination of elements in industrial waste sample and TENORM using XRF Technique in Nuclear Malaysia

    International Nuclear Information System (INIS)

    Paulus, W.; Sarimah Mahat; Meor Yusoff Meor Sulaiman

    2011-01-01

    Industrial waste such as aluminium dross and TENORM waste, oil sludge has been used as sample in this research. Determination of main elements by using X-Ray Fluorescence (XRF) in Material Technology Group, Malaysian Nuclear Agency. Results shows that main elements in these samples, aluminium and silicon, respectively. Thereby, this research shows that XRF can be considered as one of the techniques that can be used in waste characterization and furthermore, it can help researchers and engineer in the research related to waste treatment especially radioactive waste. (author)

  15. Effect of sample preparation techniques on the concentrations and distributions of elements in biological tissues using µSRXRF: a comparative study

    International Nuclear Information System (INIS)

    Al-Ebraheem, A; Dao, E; Desouza, E; McNeill, F E; Farquharson, M J; Li, C; Wainman, B C

    2015-01-01

    Routine tissue sample preparation using chemical fixatives is known to preserve the morphology of the tissue being studied. A competitive method, cryofixation followed by freeze drying, involves no chemical agents and maintains the biological function of the tissue. The possible effects of both sample preparation techniques in terms of the distribution of bio-metals (calcium (Ca), copper (Cu) zinc (Zn), and iron (Fe) specifically) in human skin tissue samples was investigated. Micro synchrotron radiation x-ray fluorescence (μSRXRF) was used to map bio-metal distribution in epidermal and dermal layers of human skin samples from various locations of the body that have been prepared using both techniques. For Ca, Cu and Zn, there were statistically significant differences between the epidermis and dermis using the freeze drying technique (p = 0.02, p < 0.01, and p < 0.01, respectively). Also using the formalin fixed, paraffin embedded technique the levels of Ca, Cu and Zn, were significantly different between the epidermis and dermis layers (p = 0.03, p < 0.01, and p < 0.01, respectively). However, the difference in levels of Fe between the epidermis and dermis was unclear and further analysis was required. The epidermis was further divided into two sub-layers, one mainly composed of the stratum corneum and the other deeper layer, the stratum basale. It was found that the difference between the distribution of Fe in the two epidermal layers using the freeze drying technique resulted in a statistically significant difference (p = 0.012). This same region also showed a difference in Fe using the formalin fixed, paraffin embedded technique (p < 0.01). The formalin fixed, paraffin embedded technique also showed a difference between the deeper epidermal layer and the dermis (p < 0.01). It can be concluded that studies involving Ca, Cu and Zn might show similar results using both sample preparation techniques, however studies involving Fe would need more

  16. Perceiving a calling, living a calling, and job satisfaction: testing a moderated, multiple mediator model.

    Science.gov (United States)

    Duffy, Ryan D; Bott, Elizabeth M; Allan, Blake A; Torrey, Carrie L; Dik, Bryan J

    2012-01-01

    The current study examined the relation between perceiving a calling, living a calling, and job satisfaction among a diverse group of employed adults who completed an online survey (N = 201). Perceiving a calling and living a calling were positively correlated with career commitment, work meaning, and job satisfaction. Living a calling moderated the relations of perceiving a calling with career commitment and work meaning, such that these relations were more robust for those with a stronger sense they were living their calling. Additionally, a moderated, multiple mediator model was run to examine the mediating role of career commitment and work meaning in the relation of perceiving a calling and job satisfaction, while accounting for the moderating role of living a calling. Results indicated that work meaning and career commitment fully mediated the relation between perceiving a calling and job satisfaction. However, the indirect effects of work meaning and career commitment were only significant for individuals with high levels of living a calling, indicating the importance of living a calling in the link between perceiving a calling and job satisfaction. Implications for research and practice are discussed. (c) 2012 APA, all rights reserved.

  17. Call Center Capacity Planning

    DEFF Research Database (Denmark)

    Nielsen, Thomas Bang

    in order to relate the results to the service levels used in call centers. Furthermore, the generic nature of the approximation is demonstrated by applying it to a system incorporating a dynamic priority scheme. In the last paper Optimization of overflow policies in call centers, overflows between agent......The main topics of the thesis are theoretical and applied queueing theory within a call center setting. Call centers have in recent years become the main means of communication between customers and companies, and between citizens and public institutions. The extensively computerized infrastructure...... in modern call centers allows for a high level of customization, but also induces complicated operational processes. The size of the industry together with the complex and labor intensive nature of large call centers motivates the research carried out to understand the underlying processes. The customizable...

  18. Application of neutron activation analysis technique in elemental determination of lichen samples

    International Nuclear Information System (INIS)

    Djoko Prakoso Dwi Atmodjo; Syukria Kurniawati; Woro Yatu Niken Syahfitri; Nana Suherman; Dadang Supriatna

    2010-01-01

    Lichen is one of the biological materials as pollution monitor that can give information about level, direction, and history of various pollutants in environment. Small sample weights and elemental content of lichens is on the order of ppm, so that its characterization requires advanced analytical techniques that has high sensitivity and capable of analyzing samples with weight of - 25 mg, such as neutron activation analysis. In this research, determination of elements was done in lichen samples obtained from Kiaracondong and Holis areas in Bandung city, to understanding the difference of industrial exposure level on surrounding environment. Samples were irradiated in RSG GA Siwabessy, Serpong, at 15 MW for 1-2 and 60 minutes for short irradiation and long irradiation, respectively. The samples were then counted using HPGe detector with GENIE 2000 software. The level of element in lichen for Kiaracondong area were Co, Cr, Cs, Fe, Mg, Mn, Sb, Sc, and V in the range of 0.55-0.86, 1.47-2.57, 0.87-1.19, 540-1005, 949-1674, 34.91-45.94, 0.08-0.14, 0.16-0.31, and ≤ 2.33 mg/kg, respectively, while for Holis area were 1.04-2.37, 4.41-10.36, 0.41-0.89, 3166-709, 1131-1422, 40.97-72.51, 0.33-0.50, 0.98-2.18, and 5.30-13.05 mg/kg respectively. From these results, it is known that pollution exposure from the semi industrial area Holis provide greater influence than in the semi industrial area Kiaracondong. (author)

  19. Feasibility of self-sampled dried blood spot and saliva samples sent by mail in a population-based study

    International Nuclear Information System (INIS)

    Sakhi, Amrit Kaur; Bastani, Nasser Ezzatkhah; Ellingjord-Dale, Merete; Gundersen, Thomas Erik; Blomhoff, Rune; Ursin, Giske

    2015-01-01

    In large epidemiological studies it is often challenging to obtain biological samples. Self-sampling by study participants using dried blood spots (DBS) technique has been suggested to overcome this challenge. DBS is a type of biosampling where blood samples are obtained by a finger-prick lancet, blotted and dried on filter paper. However, the feasibility and efficacy of collecting DBS samples from study participants in large-scale epidemiological studies is not known. The aim of the present study was to test the feasibility and response rate of collecting self-sampled DBS and saliva samples in a population–based study of women above 50 years of age. We determined response proportions, number of phone calls to the study center with questions about sampling, and quality of the DBS. We recruited women through a study conducted within the Norwegian Breast Cancer Screening Program. Invitations, instructions and materials were sent to 4,597 women. The data collection took place over a 3 month period in the spring of 2009. Response proportions for the collection of DBS and saliva samples were 71.0% (3,263) and 70.9% (3,258), respectively. We received 312 phone calls (7% of the 4,597 women) with questions regarding sampling. Of the 3,263 individuals that returned DBS cards, 3,038 (93.1%) had been packaged and shipped according to instructions. A total of 3,032 DBS samples were sufficient for at least one biomarker analysis (i.e. 92.9% of DBS samples received by the laboratory). 2,418 (74.1%) of the DBS cards received by the laboratory were filled with blood according to the instructions (i.e. 10 completely filled spots with up to 7 punches per spot for up to 70 separate analyses). To assess the quality of the samples, we selected and measured two biomarkers (carotenoids and vitamin D). The biomarker levels were consistent with previous reports. Collecting self-sampled DBS and saliva samples through the postal services provides a low cost, effective and feasible

  20. Effect of DNA extraction methods and sampling techniques on the apparent structure of cow and sheep rumen microbial communities.

    Directory of Open Access Journals (Sweden)

    Gemma Henderson

    Full Text Available Molecular microbial ecology techniques are widely used to study the composition of the rumen microbiota and to increase understanding of the roles they play. Therefore, sampling and DNA extraction methods that result in adequate yields of microbial DNA that also accurately represents the microbial community are crucial. Fifteen different methods were used to extract DNA from cow and sheep rumen samples. The DNA yield and quality, and its suitability for downstream PCR amplifications varied considerably, depending on the DNA extraction method used. DNA extracts from nine extraction methods that passed these first quality criteria were evaluated further by quantitative PCR enumeration of microbial marker loci. Absolute microbial numbers, determined on the same rumen samples, differed by more than 100-fold, depending on the DNA extraction method used. The apparent compositions of the archaeal, bacterial, ciliate protozoal, and fungal communities in identical rumen samples were assessed using 454 Titanium pyrosequencing. Significant differences in microbial community composition were observed between extraction methods, for example in the relative abundances of members of the phyla Bacteroidetes and Firmicutes. Microbial communities in parallel samples collected from cows by oral stomach-tubing or through a rumen fistula, and in liquid and solid rumen digesta fractions, were compared using one of the DNA extraction methods. Community representations were generally similar, regardless of the rumen sampling technique used, but significant differences in the abundances of some microbial taxa such as the Clostridiales and the Methanobrevibacter ruminantium clade were observed. The apparent microbial community composition differed between rumen sample fractions, and Prevotellaceae were most abundant in the liquid fraction. DNA extraction methods that involved phenol-chloroform extraction and mechanical lysis steps tended to be more comparable. However

  1. Calle Blanco

    Directory of Open Access Journals (Sweden)

    Gonzalo Cerda Brintrup

    1988-06-01

    Full Text Available Importante arteria, que comunica el sector del puerto con la plaza. Las más imponentes construcciones se sucedían de un modo continuo, encaramándose a ambos lados de la empinada calle. Antes del gran incendio de 1936 grandes casonas de madera destacaban en calle Irarrázabal y en la esquina de ésta con calle Blanco, la más hermosa construcción pertenecía a don Alberto Oyarzún y la casa vecina hacia Blanco era de don Mateo Miserda, limitada por arriba con la casa de don Augusto Van Der Steldt y ésta era seguida de la casa de don David Barrientos provista de cuatro cúpulas en las esquinas y de un amplio corredor en el frontis. Todas estas construcciones de madera fueron destruidas en el gran incendio de 1936.

  2. Investigation of an egyptian phosphate ore sample by neutron activation analysis technique

    International Nuclear Information System (INIS)

    Eissa, E.A.; Aly, R.A.; Rofail, N.B.; Hassan, A.M.

    1995-01-01

    A domestic phosphate ore sample has been analysed by means of prompt and delayed gamma-ray spectrometry following the activation by thermal neutron capture technique. The rabbit pneumatic transfer system (RPTS), long irradiation facility and two Pu/Be (2,5 Ci each) neutron sources set-Pu for prompt (n,gamma) were applied. The high purity germanium (HPGe) gamma-ray spectrometer with a personal computer analyzer (PCA) system were used for spectrum measurements. Programmes on the VAX computer were utilized for estimating the elemental concentrations of 22 out of 36 elements identified in this work. 2 tabs

  3. Time delay estimation in a reverberant environment by low rate sampling of impulsive acoustic sources

    KAUST Repository

    Omer, Muhammad

    2012-07-01

    This paper presents a new method of time delay estimation (TDE) using low sample rates of an impulsive acoustic source in a room environment. The proposed method finds the time delay from the room impulse response (RIR) which makes it robust against room reverberations. The RIR is considered a sparse phenomenon and a recently proposed sparse signal reconstruction technique called orthogonal clustering (OC) is utilized for its estimation from the low rate sampled received signal. The arrival time of the direct path signal at a pair of microphones is identified from the estimated RIR and their difference yields the desired time delay. Low sampling rates reduce the hardware and computational complexity and decrease the communication between the microphones and the centralized location. The performance of the proposed technique is demonstrated by numerical simulations and experimental results. © 2012 IEEE.

  4. Localisation and identification of radioactive particles in solid samples by means of a nuclear track technique

    International Nuclear Information System (INIS)

    Boehnke, Antje; Treutler, Hanns-Christian; Freyer, Klaus; Schubert, Michael; Holger Weiss

    2005-01-01

    This study is aimed to develop a generally applicable methodology of investigation that can be used for the localisation of single alpha-active particles in solid samples, such as industrial dust or natural soils, sediments and rocks by autoradiography using solid-state nuclear track detectors. The developed technique allows the detection of local enrichments of alpha-emitters in any solid material. The results of such an investigation are of interest from technical, biological and environmental points of view. The idea behind the methodology is to locate the position of alpha-active spots in a sample by attaching the track detector to the sample in a defined manner, thoroughly described in the paper. The located alpha-active particles are subsequently analysed by an electron microscope and an electron microprobe. An example of the application of this methodology is also given. An ultra-fine -grained ore-processing residue, which causes serious environmental pollution in the respective mining district and thus limits possible land use and affects quality of life in the area, was examined using the described technique. The investigation revealed considerable amounts of alpha-active particles in this material

  5. Coacervative extraction as a green technique for sample preparation for the analysis of organic compounds.

    Science.gov (United States)

    Melnyk, A; Wolska, L; Namieśnik, J

    2014-04-25

    One of the present trends in analytical chemistry is miniaturization, which is one of the methods of green analytical chemistry application. A particular emphasis is placed on the elimination of the use of large amounts of organic solvents which are toxic and harmful to the environment, maintaining high efficiency of the extraction process, high recovery values and low values of quantification (LOQ) and detection (LOD) limits. These requirements are fulfilled by coacervative extraction (CAE) technique. In this review, theoretical aspects of the coacervation process are presented along with environmental and bioanalytical applications of this technique, its advantages, limitations and competitiveness with other techniques. Due to its simplicity and rapidity, CAE is an excellent alternative for currently practiced procedures of sample preparation for the analysis of organic compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Sampling and examination methods used for TMI-2 samples

    International Nuclear Information System (INIS)

    Marley, A.W.; Akers, D.W.; McIsaac, C.V.

    1988-01-01

    The purpose of this paper is to summarize the sampling and examination techniques that were used in the collection and analysis of TMI-2 samples. Samples ranging from auxiliary building air to core debris were collected and analyzed. Handling of the larger samples and many of the smaller samples had to be done remotely and many standard laboratory analytical techniques were modified to accommodate the extremely high radiation fields associated with these samples. The TMI-2 samples presented unique problems with sampling and the laboratory analysis of prior molten fuel debris. 14 refs., 8 figs

  7. Amorphous and liquid samples structure and density measurements at high pressure - high temperature using diffraction and imaging techniques

    Science.gov (United States)

    Guignot, N.; King, A.; Clark, A. N.; Perrillat, J. P.; Boulard, E.; Morard, G.; Deslandes, J. P.; Itié, J. P.; Ritter, X.; Sanchez-Valle, C.

    2016-12-01

    Determination of the density and structure of liquids such as iron alloys, silicates and carbonates is a key to understand deep Earth structure and dynamics. X-ray diffraction provided by large synchrotron facilities gives excellent results as long as the signal scattered from the sample can be isolated from its environment. Different techniques already exist; we present here the implementation and the first results given by the combined angle- and energy-dispersive structural analysis and refinement (CAESAR) technique introduced by Wang et al. in 2004, that has never been used in this context. It has several advantages in the study of liquids: 1/ the standard energy-dispersive technique (EDX), fast and compatible with large multi-anvil presses frames, is used for fast analysis free of signal pollution from the sample environment 2/ some limitations of the EDX technique (homogeneity of the sample, low resolution) are irrelevant in the case of liquid signals, others (wrong intensities, escape peaks artifacts, background subtraction) are solved by the CAESAR technique 3/ high Q data (up to 15 A-1 and more) can be obtained in a few hours (usually less than 2). We present here the facilities available on the PSICHE beamline (SOLEIL synchrotron, France) and a few results obtained using a Paris-Edinburgh (PE) press and a 1200 tons load capacity multi-anvil press with a (100) DIA compression module. X-ray microtomography, used in conjunction with a PE press featuring rotating anvils (RotoPEc, Philippe et al., 2013) is also very effective, by simply measuring the 3D volume of glass or liquid spheres at HPHT, thus providing density. This can be done in conjunction with the CAESAR technique and we illustrate this point. Finally, absorption profiles can be obtained via imaging techniques, providing another independent way to measure the density of these materials. References Y. Wang et al., A new technique for angle-dispersive powder diffraction using an energy

  8. Perceiving a Calling, Living a Calling, and Job Satisfaction: Testing a Moderated, Multiple Mediator Model

    Science.gov (United States)

    Duffy, Ryan D.; Bott, Elizabeth M.; Allan, Blake A.; Torrey, Carrie L.; Dik, Bryan J.

    2012-01-01

    The current study examined the relation between perceiving a calling, living a calling, and job satisfaction among a diverse group of employed adults who completed an online survey (N = 201). Perceiving a calling and living a calling were positively correlated with career commitment, work meaning, and job satisfaction. Living a calling moderated…

  9. Reverse sample genome probing, a new technique for identification of bacteria in environmental samples by DNA hybridization, and its application to the identification of sulfate-reducing bacteria in oil field samples

    International Nuclear Information System (INIS)

    Voordouw, G.; Voordouw, J.K.; Karkhoff-Schweizer, R.R.; Fedorak, P.M.; Westlake, D.W.S.

    1991-01-01

    A novel method for identification of bacteria in environmental samples by DNA hybridization is presented. It is based on the fact that, even within a genus, the genomes of different bacteria may have little overall sequence homology. This allows the use of the labeled genomic DNA of a given bacterium (referred to as a standard) to probe for its presence and that of bacteria with highly homologous genomes in total DNA obtained from an environmental sample. Alternatively, total DNA extracted from the sample can be labeled and used to probe filters on which denatured chromosomal DNA from relevant bacterial standards has been spotted. The latter technique is referred to as reverse sample genome probing, since it is the reverse of the usual practice of deriving probes from reference bacteria for analyzing a DNA sample. Reverse sample genome probing allows identification of bacteria in a sample in a single step once a master filter with suitable standards has been developed. Application of reverse sample genome probing to the identification of sulfate-reducing bacteria in 31 samples obtained primarily from oil fields in the province of Alberta has indicated that there are at least 20 genotypically different sulfate-reducing bacteria in these samples

  10. Issues in the analyze of low content gold mining samples by fire assay technique

    Science.gov (United States)

    Cetean, Valentina

    2016-04-01

    The classic technique analyze of samples with low gold content - below 0.1 g/t (=100 ppb = parts per billion), either ore or gold sediments, involves the preparation of sample by fire assay extraction, followed by the chemical attack with aqua regia (hydrochloric and nitric acid) and measuring the gold content by atomic absorption spectrometry or inductively coupled mass spectrometry. The issues raised by this analysis are well known for the world laboratories, commercial or research ones. The author's knowledge regarding this method of determining the gold content, accumulated in such laboratory from Romania (with more than 40 years of experience, even if not longer available from 2014) confirms the obtaining of reliable results required a lot of attention, amount of work and the involving of an experienced fire assayer specialist. The analytical conclusion for a research laboratory is that most reliable and statistically valid results are till reached for samples with more than 100 ppb gold content; the degree of confidence below this value is lower than 90%. Usually, for samples below 50 ppb, it does not exceed 50-70 %, unless without very strictly control of each stage, that involve additional percentage of hours allocated for successive extracting tests and knowing more precisely the other compounds that appear in the sample (Cu, Sb, As, sulfur / sulphides, Te, organic matter, etc.) or impurities. The most important operation is the preparation, namely: - grinding and splitting of sample (which can cause uneven distribution of gold flakes in the double samples for analyzed); - pyro-metallurgical recovery of gold = fire assay stage, involving the more precise temperature control in furnace during all stages (fusion and cupellation) and adjusting of the fire assay flux components to produce a successful fusion depending of the sample matrix and content; - reducing the sample weight to decrease the amount of impurities that can be concentrated in the lead button

  11. Soil sampling

    International Nuclear Information System (INIS)

    Fortunati, G.U.; Banfi, C.; Pasturenzi, M.

    1994-01-01

    This study attempts to survey the problems associated with techniques and strategies of soil sampling. Keeping in mind the well defined objectives of a sampling campaign, the aim was to highlight the most important aspect of representativeness of samples as a function of the available resources. Particular emphasis was given to the techniques and particularly to a description of the many types of samplers which are in use. The procedures and techniques employed during the investigations following the Seveso accident are described. (orig.)

  12. Quantification of rutile in anatase by means of X-ray diffraction technique

    International Nuclear Information System (INIS)

    Macias B, L.R.; Palacios G, J.; Garcia C, R.M.

    1999-01-01

    In this work, making use of the X-ray diffraction technique, it was determined the quantification of two phases which are mixed in a crystalline sample of rutile and anatase also it is indicated the method to proceed in its evaluation, so that in the end it will be had as result of a semi-quantitative analysis of the phases that are found in the sample. The conclusion is that this method performs in samples which are presented as powders and since the different parameters with which they must be fulfilled then this should not be called quantitative but semi-quantitative and it has a margin of error in its evaluation. (Author)

  13. Behavioral Preferences for Individual Securities : The Case for Call Warrants and Call Options

    NARCIS (Netherlands)

    Ter Horst, J.R.; Veld, C.H.

    2002-01-01

    Since 1998, large investment banks have flooded the European capital markets with issues of call warrants.This has led to a unique situation in the Netherlands, where now call warrants, traded on the stock exchange, and long-term call options, traded on the options exchange, exist.Both entitle their

  14. Relaxation techniques for stress

    Science.gov (United States)

    ... raise your heart rate. This is called the stress response. Relaxation techniques can help your body relax and lower your blood pressure ... also many other types of breathing techniques you can learn. In many cases, you do not need much ... including those that cause stress. Meditation has been practiced for thousands of years, ...

  15. Technique for preparation of transmission electron microscope specimens from wire samples of Al and Al-Al2O3 alloys

    DEFF Research Database (Denmark)

    Lindbo, Jørgen

    1966-01-01

    A technique for thinning 1 mm wire samples of aluminium and aluminium-alumina alloys for transmission electron microscopy is described. The essential feature of the technique, which involves spark machining and electropolishing in a polytetrafluoroethylene holder followed by chemical polishing...

  16. Non destructive multi elemental analysis using prompt gamma neutron activation analysis techniques: Preliminary results for concrete sample

    Energy Technology Data Exchange (ETDEWEB)

    Dahing, Lahasen Normanshah [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia and Malaysian Nuclear Agency (Nuklear Malaysia), Bangi 43000, Kajang (Malaysia); Yahya, Redzuan [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia); Yahya, Roslan; Hassan, Hearie [Malaysian Nuclear Agency (Nuklear Malaysia), Bangi 43000, Kajang (Malaysia)

    2014-09-03

    In this study, principle of prompt gamma neutron activation analysis has been used as a technique to determine the elements in the sample. The system consists of collimated isotopic neutron source, Cf-252 with HPGe detector and Multichannel Analysis (MCA). Concrete with size of 10×10×10 cm{sup 3} and 15×15×15 cm{sup 3} were analysed as sample. When neutrons enter and interact with elements in the concrete, the neutron capture reaction will occur and produce characteristic prompt gamma ray of the elements. The preliminary result of this study demonstrate the major element in the concrete was determined such as Si, Mg, Ca, Al, Fe and H as well as others element, such as Cl by analysis the gamma ray lines respectively. The results obtained were compared with NAA and XRF techniques as a part of reference and validation. The potential and the capability of neutron induced prompt gamma as tool for multi elemental analysis qualitatively to identify the elements present in the concrete sample discussed.

  17. Evaluation of the Use of Two Teaching Techniques in Engineering

    Directory of Open Access Journals (Sweden)

    Jose Antonio Alvarez Salas

    2014-06-01

    Full Text Available This paper presents an analysis of the practical implementation of two teaching techniques so-called Problem-Based Learning and Cooperative Learning. These techniques were applied to some courses in the Department of Mechanical and Electrical Engineering and evaluated through assessment rubrics. In a sample of students and teachers, the assessment rubrics were applied to numerically evaluate the proportion of each course, in which the teacher uses traditional teaching versus teaching for meaningful learning. The results of the presented analysis allow to verify the use of these teaching techniques by professors of the Department of Mechanical and Electrical Engineering. This activity was developed as a part of the work established by the Institutional Development Plan of the Faculty of Engineering, which includes the strategic objective of developing an innovative educational model in the following ten years.

  18. Staff Scheduling for Inbound Call and Customer Contact Centers

    OpenAIRE

    Fukunaga, Alex; Hamilton, Ed; Fama, Jason; Andre, David; Matan, Ofer; Nourbakhsh, Illah

    2002-01-01

    The staff scheduling problem is a critical problem in the call center (or, more generally, customer contact center) industry. This article describes DIRECTOR, a staff scheduling system for contact centers. DIRECTOR is a constraint-based system that uses AI search techniques to generate schedules that satisfy and optimize a wide range of constraints and service-quality metrics. DIRECTOR has successfully been deployed at more than 800 contact centers, with significant measurable benefits, some ...

  19. Application of Cognitive and Socio-Cultural Theories in CALL

    Directory of Open Access Journals (Sweden)

    Mustafa Akın Güngör

    2011-06-01

    Full Text Available Since it is quite difficult in traditional learning atmospheres for the learners to be exposed to the target language adequately in foreign language acquisition, CALL in which virtual environment is designed in more appropriate way has given rise. Two main paradigms, cognitive model and socio-cultural theory, have also been adopted in CALL. Moreover, rather than applying one theory, combination of these paradigms is unavoidable. However, application of this combination is challenging in practice, as these two theories have different principles. Furthermore, when it comes to online education, it turns into more challenging process. In this poster this combination is presented with the help of sample applications from Gazi University.

  20. Mental, physical and social health problems of call centre workers

    Directory of Open Access Journals (Sweden)

    P Bhuyar

    2008-01-01

    Full Text Available Background: Call centre workers in BPO face unique occupational hazards - mental, physical and psychosocial. Material & Method: A sample 100 call centre workers of both sexes and from two cities Pune and Mumbai were surveyed by both qualitative and quantitative methods for the above health problems. Results: A high proportion of workers faced sleep disturbances and associated mental stress and anxiety. Sleep disturbance and anxiety was significantly more in international call centres compared to domestic. There was also disturbance in circadian rhythms due to night shift. Physical problems such as musculoskeletal disorders, obesity, eye, and hearing problems were also present. Psychosocial problems included disruption in family life, use of tobacco and alcohol, and faulty eating habits. Conclusion: Better personal management, health education and more research is indicated to study the health problems in this emerging occupation.

  1. Decomposition techniques

    Science.gov (United States)

    Chao, T.T.; Sanzolone, R.F.

    1992-01-01

    Sample decomposition is a fundamental and integral step in the procedure of geochemical analysis. It is often the limiting factor to sample throughput, especially with the recent application of the fast and modern multi-element measurement instrumentation. The complexity of geological materials makes it necessary to choose the sample decomposition technique that is compatible with the specific objective of the analysis. When selecting a decomposition technique, consideration should be given to the chemical and mineralogical characteristics of the sample, elements to be determined, precision and accuracy requirements, sample throughput, technical capability of personnel, and time constraints. This paper addresses these concerns and discusses the attributes and limitations of many techniques of sample decomposition along with examples of their application to geochemical analysis. The chemical properties of reagents as to their function as decomposition agents are also reviewed. The section on acid dissolution techniques addresses the various inorganic acids that are used individually or in combination in both open and closed systems. Fluxes used in sample fusion are discussed. The promising microwave-oven technology and the emerging field of automation are also examined. A section on applications highlights the use of decomposition techniques for the determination of Au, platinum group elements (PGEs), Hg, U, hydride-forming elements, rare earth elements (REEs), and multi-elements in geological materials. Partial dissolution techniques used for geochemical exploration which have been treated in detail elsewhere are not discussed here; nor are fire-assaying for noble metals and decomposition techniques for X-ray fluorescence or nuclear methods be discussed. ?? 1992.

  2. Evaluation of diesel particulate matter sampling techniques

    CSIR Research Space (South Africa)

    Pretorius, CJ

    2011-09-01

    Full Text Available The study evaluated diesel particulate matter (DPM) sampling methods used in the South African mining industry. The three-piece cassette respirable, open face and stopper sampling methods were compared with the SKC DPM cassette method to find a...

  3. A simple technique for measuring the superconducting critical temperature of small (>= 10 μg) samples

    International Nuclear Information System (INIS)

    Pereira, R.F.R.; Meyer, E.; Silveira, M.F. da.

    1983-01-01

    A simple technique for measuring the superconducting critical temperature of small (>=10μg) samples is described. The apparatus is built in the form of a probe, which can be introduced directly into a liquid He storage dewar and permits the determination of the critical temperature, with an imprecision of +- 0.05 K above 4.2 K, in about 10 minutes. (Author) [pt

  4. Sampling practices and analytical techniques used in the monitoring of steam and water in CEGB nuclear boilers

    International Nuclear Information System (INIS)

    Goodfellow, G.I.

    1978-01-01

    The steam and water in CEGB Magnox and AGR nuclear boilers are continuously monitored, using both laboratory techniques and on-line instrumentation, in order to maintain the chemical quality within pre-determined limits. The sampling systems in use and some of the difficulties associated with sampling requirements are discussed. The relative merits of chemical instruments installed either locally in various parts of the plant or in centralized instrument rooms are reviewed. The quality of water in nuclear boilers, as with all high-pressure steam-raising plant, is extremely high; consequently very sensitive analytical procedures are required, particularly for monitoring the feed-water of 'once-through boiler' systems. Considerable progress has been made in this field and examples are given of some of the techniques developed for analyses at the 'μ/kg' level together with some of the current problems.(author)

  5. Statistical sampling techniques as applied to OSE inspections

    International Nuclear Information System (INIS)

    Davis, J.J.; Cote, R.W.

    1987-01-01

    The need has been recognized for statistically valid methods for gathering information during OSE inspections; and for interpretation of results, both from performance testing and from records reviews, interviews, etc. Battelle Columbus Division, under contract to DOE OSE has performed and is continuing to perform work in the area of statistical methodology for OSE inspections. This paper represents some of the sampling methodology currently being developed for use during OSE inspections. Topics include population definition, sample size requirements, level of confidence and practical logistical constraints associated with the conduct of an inspection based on random sampling. Sequential sampling schemes and sampling from finite populations are also discussed. The methods described are applicable to various data gathering activities, ranging from the sampling and examination of classified documents to the sampling of Protective Force security inspectors for skill testing

  6. Techniques for sampling nuclear waste tank contents and in situ measurement of activity

    International Nuclear Information System (INIS)

    Lawrence, R.C.

    1978-04-01

    A study was conducted to develop suitable sampling equipment and techniques for characterizing the mechanical properties of nuclear wastes; identifying effective means of measuring radiation levels, temperatures, and neutron fluxes in situ in wastes; and developing a waste core sampler. A portable, stainless steel probe was developed which is placed in the tank through a riser. This probe is built for the insertion of instrumentation that can measure the contents of the tank at any level and take temperature, radiation, and neutron activation readings with reliable accuracy. A simple and reliable instrument for the in situ extraction of waste materials ranging from liquid to concrete-like substances was also developed. This portable, stainless steel waste core sampler can remove up to one liter of radioactive waste from tanks for transportation to hot cell laboratories for analysis of hardness, chemical form, and isotopic content. A cask for transporting the waste samples from the tanks to the laboratory under radiation-protected conditions was also fabricated. This cask was designed with a ''boot'' or inner-seal liner to contain any radioactive wastes that might remain on the outside of the waste core sampling device

  7. The development and use of parametric sampling techniques for probabilistic risk assessment

    International Nuclear Information System (INIS)

    Dalrymple, G.J.; Broyd, T.W.

    1987-01-01

    In order to enable evaluation to be made of proposals for the underground disposal of low and intermediate level radioactive wastes in the United Kingdom, the Department of the Environment (DoE) research programme includes development of computer-based methods for use in a multistage assessment process. To test the adequacy of the various methods of data acquisitions and radiological assessment a mock assessment exercise is currently being conducted by the department. This paper outlines the proposed methodology which provides for the use of probabilistic modelling based upon the Atomic Energy of Canada Ltd SYVAC variability analysis approach using new models (SYVAC 'A') and data appropriate to UK conditions for a deep horizontal tunnel repository concept. This chapter describes the choice of a suitable technique for the sampling of data input to the SYVAC 'A' model and techniques for analysing the predictions of dose and risk made by the model. The sensitivity of the model predictions (risk and dose to man) to the input parameters was compared for four different methods. All four methods identified the same geological parameters as the most important. (author)

  8. X-Ray Micro-Computed Tomography of Apollo Samples as a Curation Technique Enabling Better Research

    Science.gov (United States)

    Ziegler, R. A.; Almeida, N. V.; Sykes, D.; Smith, C. L.

    2014-01-01

    X-ray micro-computed tomography (micro-CT) is a technique that has been used to research meteorites for some time and many others], and recently it is becoming a more common tool for the curation of meteorites and Apollo samples. Micro-CT is ideally suited to the characterization of astromaterials in the curation process as it can provide textural and compositional information at a small spatial resolution rapidly, nondestructively, and without compromising the cleanliness of the samples (e.g., samples can be scanned sealed in Teflon bags). This data can then inform scientists and curators when making and processing future sample requests for meteorites and Apollo samples. Here we present some preliminary results on micro-CT scans of four Apollo regolith breccias. Methods: Portions of four Apollo samples were used in this study: 14321, 15205, 15405, and 60639. All samples were 8-10 cm in their longest dimension and approximately equant. These samples were micro-CT scanned on the Nikon HMXST 225 System at the Natural History Museum in London. Scans were made at 205-220 kV, 135-160 microamps beam current, with an effective voxel size of 21-44 microns. Results: Initial examination of the data identify a variety of mineral clasts (including sub-voxel FeNi metal grains) and lithic clasts within the regolith breccias. Textural information within some of the lithic clasts was also discernable. Of particular interest was a large basalt clast (approx.1.3 cc) found within sample 60639, which appears to have a sub-ophitic texture. Additionally, internal void space, e.g., fractures and voids, is readily identifiable. Discussion: It is clear from the preliminary data that micro-CT analyses are able to identify important "new" clasts within the Apollo breccias, and better characterize previously described clasts or igneous samples. For example, the 60639 basalt clast was previously believed to be quite small based on its approx.0.5 sq cm exposure on the surface of the main mass

  9. Lot quality assurance sampling techniques in health surveys in developing countries: advantages and current constraints.

    Science.gov (United States)

    Lanata, C F; Black, R E

    1991-01-01

    Traditional survey methods, which are generally costly and time-consuming, usually provide information at the regional or national level only. The utilization of lot quality assurance sampling (LQAS) methodology, developed in industry for quality control, makes it possible to use small sample sizes when conducting surveys in small geographical or population-based areas (lots). This article describes the practical use of LQAS for conducting health surveys to monitor health programmes in developing countries. Following a brief description of the method, the article explains how to build a sample frame and conduct the sampling to apply LQAS under field conditions. A detailed description of the procedure for selecting a sampling unit to monitor the health programme and a sample size is given. The sampling schemes utilizing LQAS applicable to health surveys, such as simple- and double-sampling schemes, are discussed. The interpretation of the survey results and the planning of subsequent rounds of LQAS surveys are also discussed. When describing the applicability of LQAS in health surveys in developing countries, the article considers current limitations for its use by health planners in charge of health programmes, and suggests ways to overcome these limitations through future research. It is hoped that with increasing attention being given to industrial sampling plans in general, and LQAS in particular, their utilization to monitor health programmes will provide health planners in developing countries with powerful techniques to help them achieve their health programme targets.

  10. Salivary alpha amylase in on-call from home fire and emergency service personnel

    Directory of Open Access Journals (Sweden)

    Sarah J Hall

    2017-10-01

    Full Text Available The effect of working on-call from home on the sympatho-adrenal medullary system activity is currently unknown. This study had two aims, Aim 1: examine salivary alpha amylase awakening response (AAR and diurnal salivary alpha amylase (sAA profile in fire and emergency service workers who operate on-call from home following a night on-call with a call (NIGHT-CALL, a night on-call without a call (NO-CALL and an off-call night (OFF-CALL, and Aim 2: explore whether there was an anticipatory effect of working on-call from home (ON compared to when there was an off-call (OFF on the diurnal sAA profile. Participants wore activity monitors, completed sleep and work diaries and collected seven saliva samples a day for one week. AAR area under the curve with respect to ground (AUCG, AAR area under the curve with respect to increase (AUCI, AAR reactivity, diurnal sAA slope, diurnal sAA AUCG and mean 12-h sAA concentrations were calculated. Separate generalised estimating equation models were constructed for each variable of interest for each aim. For Aim 1, there were no differences between NIGHT-CALL or NO-CALL and OFF-CALL for any response variable. For Aim 2, there was no difference between any response variable of interest when ON the following night compared to when OFF the following night (n = 14. These findings suggest that there is no effect of working on-call from home on sAA, but should be interpreted with caution, as overnight data were not collected. Future research, using overnight heart rate monitoring, could help confirm these findings.

  11. Calibrated Phase-Shifting Digital Holographic Microscope Using a Sampling Moiré Technique

    Directory of Open Access Journals (Sweden)

    Peng Xia

    2018-05-01

    Full Text Available A calibrated phase-shifting digital holographic microscope system capable of improving the quality of reconstructed images is proposed. Phase-shifting errors are introduced in phase-shifted holograms for numerous reasons, such as the non-linearity of piezoelectric transducers (PZTs, wavelength fluctuations in lasers, and environmental disturbances, leading to poor-quality reconstructions. In our system, in addition to the camera used to record object information, an extra camera is used to record interferograms, which are used to analyze phase-shifting errors using a sampling Moiré technique. The quality of the reconstructed object images can be improved by the phase-shifting error compensation algorithm. Both the numerical simulation and experiment demonstrate the effectiveness of the proposed system.

  12. Model-based quality assessment and base-calling for second-generation sequencing data.

    Science.gov (United States)

    Bravo, Héctor Corrada; Irizarry, Rafael A

    2010-09-01

    Second-generation sequencing (sec-gen) technology can sequence millions of short fragments of DNA in parallel, making it capable of assembling complex genomes for a small fraction of the price and time of previous technologies. In fact, a recently formed international consortium, the 1000 Genomes Project, plans to fully sequence the genomes of approximately 1200 people. The prospect of comparative analysis at the sequence level of a large number of samples across multiple populations may be achieved within the next five years. These data present unprecedented challenges in statistical analysis. For instance, analysis operates on millions of short nucleotide sequences, or reads-strings of A,C,G, or T's, between 30 and 100 characters long-which are the result of complex processing of noisy continuous fluorescence intensity measurements known as base-calling. The complexity of the base-calling discretization process results in reads of widely varying quality within and across sequence samples. This variation in processing quality results in infrequent but systematic errors that we have found to mislead downstream analysis of the discretized sequence read data. For instance, a central goal of the 1000 Genomes Project is to quantify across-sample variation at the single nucleotide level. At this resolution, small error rates in sequencing prove significant, especially for rare variants. Sec-gen sequencing is a relatively new technology for which potential biases and sources of obscuring variation are not yet fully understood. Therefore, modeling and quantifying the uncertainty inherent in the generation of sequence reads is of utmost importance. In this article, we present a simple model to capture uncertainty arising in the base-calling procedure of the Illumina/Solexa GA platform. Model parameters have a straightforward interpretation in terms of the chemistry of base-calling allowing for informative and easily interpretable metrics that capture the variability in

  13. Exploring antecedents and consequences of burnout in a call centre

    Directory of Open Access Journals (Sweden)

    Willie A. Visser

    2008-10-01

    Full Text Available The aim of this study was to investigate the relationship between six characteristics of call centre work environments, burnout, affective commitment and turnover intentions. These characteristics were competing management goals, work overload, electronic performance monitoring, lack of career opportunities, lack of skill variety and emotional labour. A convenient sample of employees (N = 146 was obtained from a call centre. Multiple regression analysis showed that work overload, lack of career opportunities, skill variety and emotional labour were the most important predictors of burnout. Burnout had a direct effect on turnover intentions. Affective commitment partially mediated the relationship between burnout and turnover intention.

  14. Call Centre- Computer Telephone Integration

    Directory of Open Access Journals (Sweden)

    Dražen Kovačević

    2012-10-01

    Full Text Available Call centre largely came into being as a result of consumerneeds converging with enabling technology- and by the companiesrecognising the revenue opportunities generated by meetingthose needs thereby increasing customer satisfaction. Regardlessof the specific application or activity of a Call centre, customersatisfaction with the interaction is critical to the revenuegenerated or protected by the Call centre. Physical(v, Call centreset up is a place that includes computer, telephone and supervisorstation. Call centre can be available 24 hours a day - whenthe customer wants to make a purchase, needs information, orsimply wishes to register a complaint.

  15. Voltammetric technique, a panacea for analytical examination of environmental samples

    International Nuclear Information System (INIS)

    Zahir, E.; Mohiuddin, S.; Naqvi, I.I.

    2012-01-01

    Voltammetric methods for trace metal analysis in environmental samples of marine origin like mangrove, sediments and shrimps are generally recommended. Three different electro-analytical techniques i.e. polarography, anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (ADSV) have been used. Cd/sub 2/+, Pb/sub 2/+, Cu/sub 2/+ and Mn/sub 2/+ were determined through ASV, Cr/sub 6/+ was analyzed by ADSV and Fe/sub 2/+, Zn/sub 2/+, Ni/sub 2/+ and Co/sub 2/+ were determined through polarography. Out of which pairs of Fe/sub 2/+Zn/sub 2/+ and Ni/sub 2/+Co/sub 2/+ were determined in two separate runs while Cd/sub 2/+, Pb/sub 2/+, Cu/sub 2/+ were analyzed in single run of ASV. Sensitivity and speciation capabilities of voltammetric methods have been employed. Analysis conditions were optimized that includes selection of supporting electrolyte, pH, working electrodes, sweep rate etc. Stripping voltammetry was adopted for analysis at ultra trace levels. Statistical parameters for analytical method development like selectivity factor, interference, repeatability (0.0065-0.130 macro g/g), reproducibility (0.08125-1.625 macro g/g), detection limits (0.032-5.06 macro g/g), limits of quantification (0.081-12.652 macro g/g), sensitivities (5.636-2.15 nA mL macro g-1) etc. were also determined. The percentage recoveries were found in between 95-105% using certified reference materials. Real samples of complex marine environment from Karachi coastline were also analyzed. The standard addition method was employed where any matrix effect was evidenced. (author)

  16. [Amanitine determination as an example of peptide analysis in the biological samples with HPLC-MS technique].

    Science.gov (United States)

    Janus, Tomasz; Jasionowicz, Ewa; Potocka-Banaś, Barbara; Borowiak, Krzysztof

    Routine toxicological analysis is mostly focused on the identification of non-organic and organic, chemically different compounds, but generally with low mass, usually not greater than 500–600 Da. Peptide compounds with atomic mass higher than 900 Da are a specific analytical group. Several dozen of them are highly-toxic substances well known in toxicological practice, for example mushroom toxin and animal venoms. In the paper the authors present an example of alpha-amanitin to explain the analytical problems and different original solutions in identifying peptides in urine samples with the use of the universal LC MS/MS procedure. The analyzed material was urine samples collected from patients with potential mushroom intoxication, routinely diagnosed for amanitin determination. Ultra filtration with centrifuge filter tubes (limited mass cutoff 3 kDa) was used. Filtrate fluid was directly injected on the chromatographic column and analyzed with a mass detector (MS/MS). The separation of peptides as organic, amphoteric compounds from biological material with the use of the SPE technique is well known but requires dedicated, specific columns. The presented paper proved that with the fast and simple ultra filtration technique amanitin can be effectively isolated from urine, and the procedure offers satisfactory sensitivity of detection and eliminates the influence of the biological matrix on analytical results. Another problem which had to be solved was the non-characteristic fragmentation of peptides in the MS/MS procedure providing non-selective chromatograms. It is possible to use higher collision energies in the analytical procedure, which results in more characteristic mass spectres, although it offers lower sensitivity. The ultra filtration technique as a procedure of sample preparation is effective for the isolation of amanitin from the biological matrix. The monitoring of selected mass corresponding to transition with the loss of water molecule offers

  17. Microextraction Techniques Coupled to Liquid Chromatography with Mass Spectrometry for the Determination of Organic Micropollutants in Environmental Water Samples

    Directory of Open Access Journals (Sweden)

    Mª Esther Torres Padrón

    2014-07-01

    Full Text Available Until recently, sample preparation was carried out using traditional techniques, such as liquid–liquid extraction (LLE, that use large volumes of organic solvents. Solid-phase extraction (SPE uses much less solvent than LLE, although the volume can still be significant. These preparation methods are expensive, time-consuming and environmentally unfriendly. Recently, a great effort has been made to develop new analytical methodologies able to perform direct analyses using miniaturised equipment, thereby achieving high enrichment factors, minimising solvent consumption and reducing waste. These microextraction techniques improve the performance during sample preparation, particularly in complex water environmental samples, such as wastewaters, surface and ground waters, tap waters, sea and river waters. Liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS and time-of-flight mass spectrometric (TOF/MS techniques can be used when analysing a broad range of organic micropollutants. Before separating and detecting these compounds in environmental samples, the target analytes must be extracted and pre-concentrated to make them detectable. In this work, we review the most recent applications of microextraction preparation techniques in different water environmental matrices to determine organic micropollutants: solid-phase microextraction SPME, in-tube solid-phase microextraction (IT-SPME, stir bar sorptive extraction (SBSE and liquid-phase microextraction (LPME. Several groups of compounds are considered organic micropollutants because these are being released continuously into the environment. Many of these compounds are considered emerging contaminants. These analytes are generally compounds that are not covered by the existing regulations and are now detected more frequently in different environmental compartments. Pharmaceuticals, surfactants, personal care products and other chemicals are considered micropollutants. These

  18. Sample-interpolation timing: an optimized technique for the digital measurement of time of flight for γ rays and neutrons at relatively low sampling rates

    International Nuclear Information System (INIS)

    Aspinall, M D; Joyce, M J; Mackin, R O; Jarrah, Z; Boston, A J; Nolan, P J; Peyton, A J; Hawkes, N P

    2009-01-01

    A unique, digital time pick-off method, known as sample-interpolation timing (SIT) is described. This method demonstrates the possibility of improved timing resolution for the digital measurement of time of flight compared with digital replica-analogue time pick-off methods for signals sampled at relatively low rates. Three analogue timing methods have been replicated in the digital domain (leading-edge, crossover and constant-fraction timing) for pulse data sampled at 8 GSa s −1 . Events arising from the 7 Li(p, n) 7 Be reaction have been detected with an EJ-301 organic liquid scintillator and recorded with a fast digital sampling oscilloscope. Sample-interpolation timing was developed solely for the digital domain and thus performs more efficiently on digital signals compared with analogue time pick-off methods replicated digitally, especially for fast signals that are sampled at rates that current affordable and portable devices can achieve. Sample interpolation can be applied to any analogue timing method replicated digitally and thus also has the potential to exploit the generic capabilities of analogue techniques with the benefits of operating in the digital domain. A threshold in sampling rate with respect to the signal pulse width is observed beyond which further improvements in timing resolution are not attained. This advance is relevant to many applications in which time-of-flight measurement is essential

  19. Analytical Techniques and Pharmacokinetics of Gastrodia elata Blume and Its Constituents.

    Science.gov (United States)

    Wu, Jinyi; Wu, Bingchu; Tang, Chunlan; Zhao, Jinshun

    2017-07-08

    Gastrodia elata Blume ( G. elata ), commonly called Tianma in Chinese, is an important and notable traditional Chinese medicine (TCM), which has been used in China as an anticonvulsant, analgesic, sedative, anti-asthma, anti-immune drug since ancient times. The aim of this review is to provide an overview of the abundant efforts of scientists in developing analytical techniques and performing pharmacokinetic studies of G. elata and its constituents, including sample pretreatment methods, analytical techniques, absorption, distribution, metabolism, excretion (ADME) and influence factors to its pharmacokinetics. Based on the reported pharmacokinetic property data of G. elata and its constituents, it is hoped that more studies will focus on the development of rapid and sensitive analytical techniques, discovering new therapeutic uses and understanding the specific in vivo mechanisms of action of G. elata and its constituents from the pharmacokinetic viewpoint in the near future. The present review discusses analytical techniques and pharmacokinetics of G. elata and its constituents reported from 1985 onwards.

  20. Solving mercury (Hg) speciation in soil samples by synchrotron X-ray microspectroscopic techniques

    International Nuclear Information System (INIS)

    Terzano, Roberto; Santoro, Anna; Spagnuolo, Matteo; Vekemans, Bart; Medici, Luca; Janssens, Koen; Goettlicher, Joerg; Denecke, Melissa A.; Mangold, Stefan; Ruggiero, Pacifico

    2010-01-01

    Direct mercury (Hg) speciation was assessed for soil samples with a Hg concentration ranging from 7 up to 240 mg kg -1 . Hg chemical forms were identified and quantified by sequential extractions and bulk- and micro-analytical techniques exploiting synchrotron generated X-rays. In particular, microspectroscopic techniques such as μ-XRF, μ-XRD and μ-XANES were necessary to solve bulk Hg speciation, in both soil fractions 3 S 2 Cl 2 ), and an amorphous phase containing Hg bound to chlorine and sulfur. The amount of metacinnabar and amorphous phases increased in the fraction <2 μm. No interaction among Hg-species and soil components was observed. All the observed Hg-species originated from the slow weathering of an inert Hg-containing waste material (K106, U.S. EPA) dumped in the area several years ago, which is changing into a relatively more dangerous source of pollution. - Direct mercury (Hg) speciation in chlor-alkali plant contaminated soils enabled the identification of potentially dangerous Hg-S/Cl amorphous species.

  1. Improved abdominal MRI in non-breath-holding children using a radial k-space sampling technique

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Hyuk; Choi, Young Hun; Cheon, Jung Eun; Lee, So Mi; Cho, Hyun Hae; Kim, Woo Sun; Kim, In One [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Shin, Su Mi [SMG-SNU Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of)

    2015-06-15

    Radial k-space sampling techniques have been shown to reduce motion artifacts in adult abdominal MRI. To compare a T2-weighted radial k-space sampling MRI pulse sequence (BLADE) with standard respiratory-triggered T2-weighted turbo spin echo (TSE) in pediatric abdominal imaging. Axial BLADE and respiratory-triggered turbo spin echo sequences were performed without fat suppression in 32 abdominal MR examinations in children. We retrospectively assessed overall image quality, the presence of respiratory, peristaltic and radial artifact, and lesion conspicuity. We evaluated signal uniformity of each sequence. BLADE showed improved overall image quality (3.35 ± 0.85 vs. 2.59 ± 0.59, P < 0.001), reduced respiratory motion artifact (0.51 ± 0.56 vs. 1.89 ± 0.68, P < 0.001), and improved lesion conspicuity (3.54 ± 0.88 vs. 2.92 ± 0.77, P = 0.006) compared to respiratory triggering turbo spin-echo (TSE) sequences. The bowel motion artifact scores were similar for both sequences (1.65 ± 0.77 vs. 1.79 ± 0.74, P = 0.691). BLADE introduced a radial artifact that was not observed on the respiratory triggering-TSE images (1.10 ± 0.85 vs. 0, P < 0.001). BLADE was associated with diminished signal variation compared with respiratory triggering-TSE in the liver, spleen and air (P < 0.001). The radial k-space sampling technique improved the quality and reduced respiratory motion artifacts in young children compared with conventional respiratory-triggered turbo spin-echo sequences. (orig.)

  2. Call-related factors influencing output power from mobile phones.

    Science.gov (United States)

    Hillert, Lena; Ahlbom, Anders; Neasham, David; Feychting, Maria; Järup, Lars; Navin, Roshan; Elliott, Paul

    2006-11-01

    Mobile phone use is increasing but there is also concern for adverse health effects. Well-designed prospective studies to assess several health outcomes are required. In designing a study of mobile phone use, it is important to assess which factors need to be considered in classifying the exposure to radiofrequency fields (RF). A pilot study was performed in Sweden and in the UK 2002 to 2003 to test the feasibility of recruiting a cohort of mobile phone users from a random population sample and from mobile phone subscription lists for a prospective study. As one part of this pilot study, different factors were evaluated regarding possible influence on the output power of the phones. By local switch logging, information on calls made from predefined subscriptions or dedicated handsets were obtained and the output power of phones during calls made indoors and outdoors, in moving and stationary mode, and in rural as well in urban areas were compared. In this experiment, calls were either 1, 1.5 or 5 min long. The results showed that high mobile phone output power is more frequent in rural areas whereas the other factors (length of call, moving/stationary, indoor/outdoor) were of less importance. Urban and rural area should be considered in an exposure index for classification of the exposure to RF from mobile phones and may be assessed by first base station during mobile phone calls or, if this information is not available, possibly by using home address as a proxy.

  3. An evaluation of sampling methods and supporting techniques for tackling lead in drinking water in Aberta Province

    Science.gov (United States)

    A collaborative project commenced in August 2013 with the aim of demonstrating a range of techniques that can be used in tackling the problems of lead in drinking water. The main project was completed in March 2014, with supplementary sampling exercises in mid-2014. It involved t...

  4. Facility and application of nuclear and supplementary analytical techniques at Dalat Nuclear Research Institute

    International Nuclear Information System (INIS)

    Nguyen Mong Sinh; Ho Manh Dung; Nguyen Thanh Binh

    2006-01-01

    The main applications of the nuclear and supplementary analytical techniques (N and SATs) in the Dalat Nuclear Research Institute (DNRI) and the facilities for the techniques are presented. The NATs in DNRI include the neutron activation analysis (NAA) with instrumental, radiochemical and prompt gamma methods (INAA, RNAA, PGNAA), the X-ray fluorescence analysis (XRFA) and the low-level counting and spectrometry. The sample irradiation sites for NAA, the automatic and manual pneumatic transfer systems, were installed at channels 7-1 and 13-2 and rotary rack on the Dalat research reactor. An ORTEC automatic sample changer (model ASC2) for γ-ray counting was equipped. A computer software for NAA based on the k 0 -standardization method for calculation of elemental concentration was developed. The low-level counting and spectrometry techniques have been setup. The devices required for sampling, sample preparation and data processing have also been equipped. The applications of N and SATs for determination of elemental composition, particularly important in providing data so-called trace elements, radionuclides and multi-element have been enlarged for objects of geology, archaeology, bio-agriculture, health-nutrition and environment. The implementation a quality system for N and SATs has been planned and initiated. (author)

  5. Huffman-based code compression techniques for embedded processors

    KAUST Repository

    Bonny, Mohamed Talal

    2010-09-01

    The size of embedded software is increasing at a rapid pace. It is often challenging and time consuming to fit an amount of required software functionality within a given hardware resource budget. Code compression is a means to alleviate the problem by providing substantial savings in terms of code size. In this article we introduce a novel and efficient hardware-supported compression technique that is based on Huffman Coding. Our technique reduces the size of the generated decoding table, which takes a large portion of the memory. It combines our previous techniques, Instruction Splitting Technique and Instruction Re-encoding Technique into new one called Combined Compression Technique to improve the final compression ratio by taking advantage of both previous techniques. The instruction Splitting Technique is instruction set architecture (ISA)-independent. It splits the instructions into portions of varying size (called patterns) before Huffman coding is applied. This technique improves the final compression ratio by more than 20% compared to other known schemes based on Huffman Coding. The average compression ratios achieved using this technique are 48% and 50% for ARM and MIPS, respectively. The Instruction Re-encoding Technique is ISA-dependent. It investigates the benefits of reencoding unused bits (we call them reencodable bits) in the instruction format for a specific application to improve the compression ratio. Reencoding those bits can reduce the size of decoding tables by up to 40%. Using this technique, we improve the final compression ratios in comparison to the first technique to 46% and 45% for ARM and MIPS, respectively (including all overhead that incurs). The Combined Compression Technique improves the compression ratio to 45% and 42% for ARM and MIPS, respectively. In our compression technique, we have conducted evaluations using a representative set of applications and we have applied each technique to two major embedded processor architectures

  6. A comparative study of 232Th and 238U activity estimation in soil samples by gamma spectrometry and Neutron Activation Analysis (NAA) technique

    International Nuclear Information System (INIS)

    Rekha, A.K.; Anilkumar, S.; Narayani, K.; Babu, D.A.R.

    2012-01-01

    Radioactivity in the environment is mainly due to the naturally occurring radionuclides like uranium, thorium with their daughter products and potassium. Even though Gamma spectrometry is the most commonly used non destructive method for the quantification of these naturally occurring radionuclides, Neutron Activation Analysis (NAA), a well established analytical technique, can also be used. But the NAA technique is a time consuming process and needs proper standards, proper sample preparation etc. In this paper, the 232 Th and 238 U activity estimated using gamma ray spectrometry and NAA technique are compared. In the case of direct gamma spectrometry method, the samples were analysed after sealing in a 250 ml container. Whereas for the NAA, about 300 mg of each sample, after irradiation were subjected to gamma spectrometry. The 238 U and 232 Th activities (in Bq/kg) in samples were estimated after the proper efficiency correction and were compared. The estimated activities by these two methods are in good agreement. The variation in 238 U and 232 Th activity values are within ± 15% which are acceptable for environmental samples

  7. Gridsampler – A Simulation Tool to Determine the Required Sample Size for Repertory Grid Studies

    OpenAIRE

    Heckmann, Mark; Burk, Lukas

    2017-01-01

    The repertory grid is a psychological data collection technique that is used to elicit qualitative data in the form of attributes as well as quantitative ratings. A common approach for evaluating multiple repertory grid data is sorting the elicited bipolar attributes (so called constructs) into mutually exclusive categories by means of content analysis. An important question when planning this type of study is determining the sample size needed to a) discover all attribute categories relevant...

  8. Probabilistic techniques using Monte Carlo sampling for multi- component system diagnostics

    International Nuclear Information System (INIS)

    Aumeier, S.E.; Lee, J.C.; Akcasu, A.Z.

    1995-01-01

    We outline the structure of a new approach at multi-component system fault diagnostics which utilizes detailed system simulation models, uncertain system observation data, statistical knowledge of system parameters, expert opinion, and component reliability data in an effort to identify incipient component performance degradations of arbitrary number and magnitude. The technique involves the use of multiple adaptive Kalman filters for fault estimation, the results of which are screened using standard hypothesis testing procedures to define a set of component events that could have transpired. Latin Hypercube sample each of these feasible component events in terms of uncertain component reliability data and filter estimates. The capabilities of the procedure are demonstrated through the analysis of a simulated small magnitude binary component fault in a boiling water reactor balance of plant. The results show that the procedure has the potential to be a very effective tool for incipient component fault diagnosis

  9. Use of a multigrid technique to study effects of limited sampling of heterogeneity on transport prediction

    International Nuclear Information System (INIS)

    Cole, C.R.; Foote, H.P.

    1987-02-01

    Reliable ground water transport prediction requires accurate spatial and temporal characterization of a hydrogeologic system. However, cost constraints and the desire to maintain site integrity by minimizing drilling can restrict the amount of spatial sampling that can be obtained to resolve the flow parameter variability associated with heterogeneities. This study quantifies the errors in subsurface transport predictions resulting from incomplete characterization of hydraulic conductivity heterogeneity. A multigrid technique was used to simulate two-dimensional flow velocity fields with high resolution. To obtain these velocity fields, the finite difference code MGRID, which implements a multigrid solution technique, was applied to compute stream functions on a 256-by-256 grid for a variety of hypothetical systems having detailed distributions of hydraulic conductivity. Spatial variability in hydraulic conductivity distributions was characterized by the components in the spectrum of spatial frequencies. A low-pass spatial filtering technique was applied to the base case hydraulic conductivity distribution to produce a data set with lower spatial frequency content. Arrival time curves were then calculated for filtered hydraulic conductivity distribution and compared to base case results to judge the relative importance of the higher spatial frequency components. Results indicate a progression from multimode to single-mode arrival time curves as the number and extent of distinct flow pathways are reduced by low-pass filtering. This relationship between transport predictions and spatial frequencies was used to judge the consequences of sampling the hydraulic conductivity with reduced spatial resolution. 22 refs., 17 figs

  10. Manipulation of biological samples using micro and nano techniques

    DEFF Research Database (Denmark)

    Castillo, Jaime; Dimaki, Maria; Svendsen, Winnie Edith

    2009-01-01

    to their natural structure. Thanks to the advances in micro- and nanofabrication during the last decades several manipulation techniques offer us the possibility to image, characterize and manipulate biological material in a controlled way. Using these techniques the integration of biomaterials with remarkable...

  11. Development of analytical techniques for water and environmental samples (2)

    Energy Technology Data Exchange (ETDEWEB)

    Eum, Chul Hun; Jeon, Chi Wan; Jung, Kang Sup; Song, Kyung Sun; Kim, Sang Yeon [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    The purpose of this study is to develop new analytical methods with good detection limit for toxic inorganic and organic compounds. The analyses of CN, organic acids, particulate materials in environmental samples have been done using several methods such as Ion Chromatography, SPE, SPME, GC/MS, GC/FID, SPLITT (split-flow thin cell fractionation) during the second year of this project. Advantage and disadvantage of several distillation method (by KS, JIS, EPA) for CN analysis in wastewater were investigated. As the results, we proposed new distillation apparatus for CN analysis, which was proved to be simpler, faster and to get better recovery than conventional apparatus. And ion chromatograph/pulsed amperometric detector (IC/PAD) system instead of colorimetry for CN detection was setup to solve matrix interference. And SPE(solid phase extraction) and SPME (solid phase micro extraction) as liquid-solid extraction technique were applied to the analysis of phenols in wastewater. Optimum experimental conditions and factors influencing analytical results were determined. From these results, It could be concluded that C{sub 18} cartridge and polystyrene-divinylbenzene disk in SPE method, polyacrylate fiber in SPME were proper solid phase adsorbent for phenol. Optimum conditions to analyze phenol derivatives simultaneously were established. Also, Continuous SPLITT (Split-flow thin cell) Fractionation (CSF) is a new preparative separation technique that is useful for fractionation of particulate and macromolecular materials. CSF is carried out in a thin ribbon-like channel equipped with two splitters at both inlet and outlet of the channel. In this work, we set up a new CSF system, and tested using polystyrene latex standard particles. And then we fractionated particles contained in air and underground water based on their sedimentation coefficients using CSF. (author). 27 refs., 13 tabs., 31 figs.

  12. The difficult medical emergency call

    DEFF Research Database (Denmark)

    Møller, Thea Palsgaard; Kjærulff, Thora Majlund; Viereck, Søren

    2017-01-01

    BACKGROUND: Pre-hospital emergency care requires proper categorization of emergency calls and assessment of emergency priority levels by the medical dispatchers. We investigated predictors for emergency call categorization as "unclear problem" in contrast to "symptom-specific" categories and the ......BACKGROUND: Pre-hospital emergency care requires proper categorization of emergency calls and assessment of emergency priority levels by the medical dispatchers. We investigated predictors for emergency call categorization as "unclear problem" in contrast to "symptom-specific" categories...... and the effect of categorization on mortality. METHODS: Register-based study in a 2-year period based on emergency call data from the emergency medical dispatch center in Copenhagen combined with nationwide register data. Logistic regression analysis (N = 78,040 individuals) was used for identification...

  13. BUSINESS MODELS FOR EXTENDING OF 112 EMERGENCY CALL CENTER CAPABILITIES WITH E-CALL FUNCTION INSERTION

    Directory of Open Access Journals (Sweden)

    Pop Dragos Paul

    2010-12-01

    Full Text Available The present article concerns present status of implementation in Romania and Europe of eCall service and the proposed business models regarding eCall function implementation in Romania. eCall system is used for reliable transmission in case of crush between In Vehicle System and Public Service Answering Point, via the voice channel of cellular and Public Switched Telephone Network (PSTN. eCall service could be initiated automatically or manual the driver. All data presented in this article are part of researches made by authors in the Sectorial Contract Implementation study regarding eCall system, having as partners ITS Romania and Electronic Solution, with the Romanian Ministry of Communication and Information Technology as beneficiary.

  14. Characterization technique for detection of atom-size crystalline defects and strains using two-dimensional fast-Fourier-transform sampling Moiré method

    Science.gov (United States)

    Kodera, Masako; Wang, Qinghua; Ri, Shien; Tsuda, Hiroshi; Yoshioka, Akira; Sugiyama, Toru; Hamamoto, Takeshi; Miyashita, Naoto

    2018-04-01

    Recently, we have developed a two-dimensional (2D) fast-Fourier-transform (FFT) sampling Moiré technique to visually and quantitatively determine the locations of minute defects in a transmission electron microscopy (TEM) image. We applied this technique for defect detection with GaN high electron mobility transistor (HEMT) devices, and successfully and clearly visualized atom-size defects in AlGaN/GaN crystalline structures. The defect density obtained in the AlGaN/GaN structures is ∼1013 counts/cm2. In addition, we have successfully confirmed that the distribution and number of defects closely depend on the process conditions. Thus, this technique is quite useful for a device development. Moreover, the strain fields in an AlGaN/GaN crystal were effectively calculated with nm-scale resolution using this method. We also demonstrated that this sampling Moiré technique is applicable to silicon devices, which have principal directions different from those of AlGaN/GaN crystals. As a result, we believe that the 2D FFT sampling Moiré method has great potential applications to the discovery of new as yet unknown phenomena occurring between the characteristics of a crystalline material and device performance.

  15. Comparison of sampling techniques for Bayesian parameter estimation

    Science.gov (United States)

    Allison, Rupert; Dunkley, Joanna

    2014-02-01

    The posterior probability distribution for a set of model parameters encodes all that the data have to tell us in the context of a given model; it is the fundamental quantity for Bayesian parameter estimation. In order to infer the posterior probability distribution we have to decide how to explore parameter space. Here we compare three prescriptions for how parameter space is navigated, discussing their relative merits. We consider Metropolis-Hasting sampling, nested sampling and affine-invariant ensemble Markov chain Monte Carlo (MCMC) sampling. We focus on their performance on toy-model Gaussian likelihoods and on a real-world cosmological data set. We outline the sampling algorithms themselves and elaborate on performance diagnostics such as convergence time, scope for parallelization, dimensional scaling, requisite tunings and suitability for non-Gaussian distributions. We find that nested sampling delivers high-fidelity estimates for posterior statistics at low computational cost, and should be adopted in favour of Metropolis-Hastings in many cases. Affine-invariant MCMC is competitive when computing clusters can be utilized for massive parallelization. Affine-invariant MCMC and existing extensions to nested sampling naturally probe multimodal and curving distributions.

  16. Recent advances in periodontal microbiology: An update on cultivation techniques

    Directory of Open Access Journals (Sweden)

    Kishore G Bhat

    2014-01-01

    Full Text Available Microbial members of the subgingival plaque community play a major role in the initiation and progression of periodontal diseases. Majority of these bacteria are anaerobic in nature and several anaerobic systems have been used for their cultivation. Among them anaerobic jars are the most popular and are routinely used for the detection of periodontal pathogens from clinical samples. Despite best efforts, a significant portion of oral microbes have not yet been cultivated and several hypotheses have been put forth to explain this anomaly. This has led to renewed efforts to cultivate the oral bacteria so far identified only by their molecular signatures resulting in improvisation of existing culture techniques and devising novel methods of isolation. Several devices have been used on environmental samples successfully: One method called "minitrap" has been successfully adapted to oral cavity and has shown great promise in isolation of not yet cultivated oral bacterial species. These newer techniques are sure to shed more light on the role of microbes in the etiology of periodontal diseases.

  17. Use of the electrodeposition technique in the preparation of samples of 237Np and its determination by alpha spectrometry

    International Nuclear Information System (INIS)

    Mertzig, W.; Matsuda, H.T.; Araujo, B.F. de; Araujo, J.A. de.

    1981-05-01

    The electroplating technique to prepare 237 Np source and its determination by alpha spectrometry is presented. The samples were prepared using a lucite-eletrolitic cell manufactured at IPEN, specially to trace amounts of actinides. A polished brass disk coated with Ni film has been used as cathodo and a fixed Pt wire as anode. The electroplated samples were alpha counted using a surface barrier detector. The optimum conditions to obtain the quantitative deposition of 237 Np have been achieved by studying the effects of some parameters as current density, pH and concentration of eletrolitic solution and time of eletrodeposition, using a carrier technique. After preliminary purification, the method is applied to control trace amounts of 237 Np in the Purex process solutions. (Author) [pt

  18. [A comparison of convenience sampling and purposive sampling].

    Science.gov (United States)

    Suen, Lee-Jen Wu; Huang, Hui-Man; Lee, Hao-Hsien

    2014-06-01

    Convenience sampling and purposive sampling are two different sampling methods. This article first explains sampling terms such as target population, accessible population, simple random sampling, intended sample, actual sample, and statistical power analysis. These terms are then used to explain the difference between "convenience sampling" and purposive sampling." Convenience sampling is a non-probabilistic sampling technique applicable to qualitative or quantitative studies, although it is most frequently used in quantitative studies. In convenience samples, subjects more readily accessible to the researcher are more likely to be included. Thus, in quantitative studies, opportunity to participate is not equal for all qualified individuals in the target population and study results are not necessarily generalizable to this population. As in all quantitative studies, increasing the sample size increases the statistical power of the convenience sample. In contrast, purposive sampling is typically used in qualitative studies. Researchers who use this technique carefully select subjects based on study purpose with the expectation that each participant will provide unique and rich information of value to the study. As a result, members of the accessible population are not interchangeable and sample size is determined by data saturation not by statistical power analysis.

  19. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  20. Analysis of boron utilization in sample preparation for microorganisms detection by neutron radiography technique

    International Nuclear Information System (INIS)

    Wacha, Reinaldo; Crispim, Verginia R.

    2000-01-01

    The neutron radiography technique applied to the microorganisms detection is the study of a new and faster alternative for diagnosis of infectious means. This work presents the parameters and the effects involved in the use of the boron as a conversion agent, that convert neutrons in a particles, capable ones of generating latent tracks in a solid state nuclear tracks detector, CR-39. The collected samples are doped with the boron by the incubation method, propitiating an interaction microorganisms/boron, that will guarantee the identification of the images of those microorganisms, through your morphology. (author)

  1. Q-Technique and Graphics Research.

    Science.gov (United States)

    Kahle, Roger R.

    Because Q-technique is as appropriate for use with visual and design items as for use with words, it is not stymied by the topics one is likely to encounter in graphics research. In particular Q-technique is suitable for studying the so-called "congeniality" of typography, for various copytesting usages, and for multivariate graphics research. The…

  2. Assessing call centers’ success:

    Directory of Open Access Journals (Sweden)

    Hesham A. Baraka

    2013-07-01

    This paper introduces a model to evaluate the performance of call centers based on the Delone and McLean Information Systems success model. A number of indicators are identified to track the call center’s performance. Mapping of the proposed indicators to the six dimensions of the D&M model is presented. A Weighted Call Center Performance Index is proposed to assess the call center performance; the index is used to analyze the effect of the identified indicators. Policy-Weighted approach was used to assume the weights with an analysis of different weights for each dimension. The analysis of the different weights cases gave priority to the User satisfaction and net Benefits dimension as the two outcomes from the system. For the input dimensions, higher priority was given to the system quality and the service quality dimension. Call centers decision makers can use the tool to tune the different weights in order to reach the objectives set by the organization. Multiple linear regression analysis was used in order to provide a linear formula for the User Satisfaction dimension and the Net Benefits dimension in order to be able to forecast the values for these two dimensions as function of the other dimensions

  3. Self-Regulatory Processes Mediating between Career Calling and Perceived Employability and Life Satisfaction in Emerging Adults

    Science.gov (United States)

    Praskova, Anna; Creed, Peter A.; Hood, Michelle

    2015-01-01

    We tested a cross-sectional, mediation model of career calling, in which career calling was associated positively with life satisfaction and perceptions of future employability, and these relationships were explained by the self-regulatory mechanisms of work effort, career strategies, and emotional regulation. Using a sample of 664 emerging adults…

  4. 78 FR 76218 - Rural Call Completion

    Science.gov (United States)

    2013-12-17

    ... calls to rural areas, and enforce restrictions against blocking, choking, reducing, or restricting calls... to alert the Commission of systemic problems receiving calls from a particular originating long... associated with completing calls to rural areas. These rules will also enhance our ability to enforce...

  5. Long-distance calls in Neotropical primates

    Directory of Open Access Journals (Sweden)

    Oliveira Dilmar A.G.

    2004-01-01

    Full Text Available Long-distance calls are widespread among primates. Several studies concentrate on such calls in just one or in few species, while few studies have treated more general trends within the order. The common features that usually characterize these vocalizations are related to long-distance propagation of sounds. The proposed functions of primate long-distance calls can be divided into extragroup and intragroup ones. Extragroup functions relate to mate defense, mate attraction or resource defense, while intragroup functions involve group coordination or alarm. Among Neotropical primates, several species perform long-distance calls that seem more related to intragroup coordination, markedly in atelines. Callitrichids present long-distance calls that are employed both in intragroup coordination and intergroup contests or spacing. Examples of extragroup directed long-distance calls are the duets of titi monkeys and the roars and barks of howler monkeys. Considerable complexity and gradation exist in the long-distance call repertoires of some Neotropical primates, and female long-distance calls are probably more important in non-duetting species than usually thought. Future research must focus on larger trends in the evolution of primate long-distance calls, including the phylogeny of calling repertoires and the relationships between form and function in these signals.

  6. Alarm Fatigue vs User Expectations Regarding Context-Aware Alarm Handling in Hospital Environments Using CallMeSmart.

    Science.gov (United States)

    Solvoll, Terje; Arntsen, Harald; Hartvigsen, Gunnar

    2017-01-01

    Surveys and research show that mobile communication systems in hospital settings are old and cause frequent interruptions. In the quest to remedy this, an Android based communication system called CallMeSmart tries to encapsulate most of the frequent communication into one hand held device focusing on reducing interruptions and at the same time make the workday easier for healthcare workers. The objective of CallMeSmart is to use context-awareness techniques to automatically monitor the availability of physicians' and nurses', and use this information to prevent or route phone calls, text messages, pages and alarms that would otherwise compromise patient care. In this paper, we present the results from interviewing nurses on alarm fatigue and their expectations regarding context-aware alarm handling using CallMeSmart.

  7. Comparison of Two Surface Contamination Sampling Techniques Conducted for the Characterization of Two Pajarito Site Manhattan Project National Historic Park Properties

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Tammy Ann [Montana Tech of the Univ. of Montana, Butte, MT (United States); Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-29

    Technical Area-18 (TA-18), also known as Pajarito Site, is located on Los Alamos National Laboratory property and has historic buildings that will be included in the Manhattan Project National Historic Park. Characterization studies of metal contamination were needed in two of the four buildings that are on the historic registry in this area, a “battleship” bunker building (TA-18-0002) and the Pond cabin (TA-18-0029). However, these two buildings have been exposed to the elements, are decades old, and have porous and rough surfaces (wood and concrete). Due to these conditions, it was questioned whether standard wipe sampling would be adequate to detect surface dust metal contamination in these buildings. Thus, micro-vacuum and surface wet wipe sampling techniques were performed side-by-side at both buildings and results were compared statistically. A two-tail paired t-test revealed that the micro-vacuum and wet wipe techniques were statistically different for both buildings. Further mathematical analysis revealed that the wet wipe technique picked up more metals from the surface than the microvacuum technique. Wet wipes revealed concentrations of beryllium and lead above internal housekeeping limits; however, using an yttrium normalization method with linear regression analysis between beryllium and yttrium revealed a correlation indicating that the beryllium levels were likely due to background and not operational contamination. PPE and administrative controls were implemented for National Park Service (NPS) and Department of Energy (DOE) tours as a result of this study. Overall, this study indicates that the micro-vacuum technique may not be an efficient technique to sample for metal dust contamination.

  8. Diurnal activity of four species of thrips (Thysanoptera: Thripidae) and efficiencies of three nondestructive sampling techniques for thrips in mango inflorescences.

    Science.gov (United States)

    Aliakbarpour, H; Rawi, Che Salmah Md

    2010-06-01

    Thrips cause considerable economic loss to mango, Mangifera indica L., in Penang, Malaysia. Three nondestructive sampling techniques--shaking mango panicles over a moist plastic tray, washing the panicles with ethanol, and immobilization of thrips by using CO2--were evaluated for their precision to determine the most effective technique to capture mango flower thrips (Thysanoptera: Thripidae) in an orchard located at Balik Pulau, Penang, Malaysia, during two flowering seasons from December 2008 to February 2009 and from August to September 2009. The efficiency of each of the three sampling techniques was compared with absolute population counts on whole panicles as a reference. Diurnal flight activity of thrips species was assessed using yellow sticky traps. All three sampling methods and sticky traps were used at two hourly intervals from 0800 to 1800 hours to get insight into diurnal periodicity of thrips abundance in the orchard. Based on pooled data for the two seasons, the CO2 method was the most efficient procedure extracting 80.7% adults and 74.5% larvae. The CO2 method had the lowest relative variation and was the most accurate procedure compared with the absolute method as shown by regression analysis. All collection techniques showed that the numbers of all thrips species in mango panicles increased after 0800 hours, reaching a peak between 1200 and 1400 hours. Adults thrips captured on the sticky traps were the most abundant between 0800-1000 and 1400-1600 hours. According to results of this study, the CO2 method is recommended for sampling of thrips in the field. It is a nondestructive sampling procedure that neither damages flowers nor diminishes fruit production. Management of thrips populations in mango orchards with insecticides would be more effectively carried out during their peak population abundance on the flower panicles at midday to 1400 hours.

  9. Rapidly Mixing Gibbs Sampling for a Class of Factor Graphs Using Hierarchy Width.

    Science.gov (United States)

    De Sa, Christopher; Zhang, Ce; Olukotun, Kunle; Ré, Christopher

    2015-12-01

    Gibbs sampling on factor graphs is a widely used inference technique, which often produces good empirical results. Theoretical guarantees for its performance are weak: even for tree structured graphs, the mixing time of Gibbs may be exponential in the number of variables. To help understand the behavior of Gibbs sampling, we introduce a new (hyper)graph property, called hierarchy width . We show that under suitable conditions on the weights, bounded hierarchy width ensures polynomial mixing time. Our study of hierarchy width is in part motivated by a class of factor graph templates, hierarchical templates , which have bounded hierarchy width-regardless of the data used to instantiate them. We demonstrate a rich application from natural language processing in which Gibbs sampling provably mixes rapidly and achieves accuracy that exceeds human volunteers.

  10. Importance sampling techniques and treatment of electron transport in MCNP 4A

    International Nuclear Information System (INIS)

    Ueki, K.

    1994-01-01

    The continuous energy Monte Carlo code MCNP was developed by the Radiation Transport Group at Los Alamos National Laboratory and the MCNP 4A version is available, now. The MCNP 4A is able to do the coupled neutron-secondary gamma-ray-electron-bremsstrahlung calculation. The calculated results, such as energy spectra, tally fluctuation chart, and geometrical input data can be displayed by using a work station. The document of the MCNP 4A code has no description on the subroutines, except few ones of 'SOURCE', 'TALLYX'. However, when we want to improve the MCNP Monte Carlo sampling techniques to get more accuracy or efficiency results for some problems, some subroutines are required or needed to revised. Three subroutines have been revised and built in the MCNP 4A code. (author)

  11. Determination of elemental in soil samples from Gebeng area using NAA technique

    International Nuclear Information System (INIS)

    Md Suhaimi Elias; Wo, Y.M.; Mohd Suhaimi Hamzah

    2016-01-01

    Rapid development and urbanization will increase number of residence and industrial area. Without proper management and control of pollution, these will give an adverse effect to environment and human life. The objective of this study to identify and quantify key contaminants into the environment of the Gebeng area as a result of industrial and human activities. Gebeng area was gazetted as one of the industrial estate in Pahang state. Assessment of elemental pollution in soil of Gebeng area base on level of concentration, enrichment factor and geo-accumulation index. The enrichment factors (EFs) were determined by the elemental rationing method, whilst the geo-accumulation index (I_g_e_o) by comparing of current to continental crustal average concentration of element. Twenty-seven of soil samples were collected from Gebeng area. Soil samples were analysed by using Neutron Activation Analyses (NAA) technique. The obtained data showed higher concentration of iron (Fe) due to abundance in soil compared to other elements. The results of enrichment factor showed that Gebeng area have enrich with elements of As, Br, Hf, Sb, Th and U. Base on the geo-accumulation index (I_g_e_o) classification, the soil quality of Gebeng area can be classified as class 0, (uncontaminated) to Class 3, (moderately to heavily contaminated). (author)

  12. A Novel Semi-Supervised Electronic Nose Learning Technique: M-Training

    Directory of Open Access Journals (Sweden)

    Pengfei Jia

    2016-03-01

    Full Text Available When an electronic nose (E-nose is used to distinguish different kinds of gases, the label information of the target gas could be lost due to some fault of the operators or some other reason, although this is not expected. Another fact is that the cost of getting the labeled samples is usually higher than for unlabeled ones. In most cases, the classification accuracy of an E-nose trained using labeled samples is higher than that of the E-nose trained by unlabeled ones, so gases without label information should not be used to train an E-nose, however, this wastes resources and can even delay the progress of research. In this work a novel multi-class semi-supervised learning technique called M-training is proposed to train E-noses with both labeled and unlabeled samples. We employ M-training to train the E-nose which is used to distinguish three indoor pollutant gases (benzene, toluene and formaldehyde. Data processing results prove that the classification accuracy of E-nose trained by semi-supervised techniques (tri-training and M-training is higher than that of an E-nose trained only with labeled samples, and the performance of M-training is better than that of tri-training because more base classifiers can be employed by M-training.

  13. The three dimensional X-ray diffraction technique

    DEFF Research Database (Denmark)

    Juul Jensen, Dorte; Poulsen, Henning Friis

    2012-01-01

    This introductory tutorial describes the so called 3 dimensional X-ray diffraction (3DXRD) technique, which allows bulk non-destructive structural characterizations of crystalline materials. The motivations and history behind the development of this technique are described and its potentials...

  14. Application of the spectrometric and radiochemical techniques in analyzing environmental samples from the Bulgarian Black Sea region

    International Nuclear Information System (INIS)

    Veleva, B.S.; Mungov, G.; Galabov, N.; Kolarova, M.; Guenchev, T.

    1999-01-01

    Development of the appropriate methods and techniques for marine and atmospheric radioactivity measurements in the NIMH-BAS during the last 5 years is presented. Approaches for pre-concentration of the radionuclides from the atmosphere and sea water samples followed with reliable radiochemical methods for radionuclides separation and low level counting are discussed. Dissolved radiocesium concentrations measured in a period of time starting in 1993 show some decrease with years and spatial variations probably due to the hydrophysical features of the sampling sides - the lower measured concentrations during 1995 and 1998 correspond to the lower salinity. Application of the radiochemical separation of Plutonium, Thorium, 90 Sr and Americium on the samples from the Bulgarian Black Sea coastal region is reported. (author)

  15. Stressful Demands or Helpful Guidance? The Role of Display Rules in Indian Call Centers

    Science.gov (United States)

    Little, Laura M.; Nelson, Debra L.; Quade, Matthew J.; Ward, Andrew

    2011-01-01

    This paper utilizes conservation of resources (COR) theory and two of Hofstede's (1980) dimensions of culture (individualism and power distance) to examine the impact of display rules on job satisfaction and performance in an Indian call center sample. Contrary to findings in an American sample (Wilk & Moynihan, 2005), we proposed that due to…

  16. Sleep Quality of Call Handlers Employed in International Call Centers in National Capital Region of Delhi, India.

    Science.gov (United States)

    Raja, J D; Bhasin, S K

    2016-10-01

    Call center sector in India is a relatively new and fast growing industry driving employment and growth in modern India today. Most international call centers in National Capital Region (NCR) of Delhi operate at odd work hours corresponding to a time suitable fortheir international customers. The sleep quality of call handlers employed in these call centers is in jeopardy owing to their altered sleep schedule. To assess the sleep quality and determine its independent predictors among call handlers employed in international call centers in NCR of Delhi. A cross-sectional questionnaire-based study was conducted on 375 call handlers aged 18-39 years employed in international call centers in NCR of Delhi. Sleep quality was assessed using Athens Insomnia scale along with a pre-tested, structured questionnaire. The mean age of respondents was 24.6 (SD 2.4) years. 78% of participants were male. 83.5% of respondents were unmarried. 44.3% of call handlers were cigarette smokers. Physical ailments were reported by 37% call handlers. 77.6% of call handlers had somesuspicion of insomnia or suspected insomnia; the rest had no sleep problem. Smoking, poor social support, heavy workload, lack of relaxation facility at office, and prolonged travel time to office were independent predictors of sleep quality (pSafeguarding their health becomes an occupational health challenge to public health specialists.

  17. Elemental analysis of water and soil environmental samples in Tabuk area by neutron capture gamma-ray spectroscopy techniques

    International Nuclear Information System (INIS)

    Al-Aseery, Sh.M.; Alamoudi, Z.; Hassan, A.M.

    2006-01-01

    The prompt and delayed gamma-rays due to neutron capture in the nuclei of the constituent elements of three soil samples and one drinking water sample have been measured. The 252 Cf and 226 Ra/Be isotopic neutron sources are used for neutron irradiation. Also, the hyper pure germanium detection system is used. The soil samples were from Astra, Tadco and El-Gammaz farms, while the water sample was taken from Tabuk city. In case of prompt gamma-ray analysis, a total of 16 elements were identified and the concentration percentage values by weight were calculated for: C, Na, Mg, Al, Si, S, Cl,, Ca, Ti, Cr, Mn, Fe, Co, Zn, Sr ad Pb elements. A comparative study between the results obtained in this work and the results obtained by ICP-MS and EDX-Ray techniques for the same samples is given

  18. Determination of heavy metals at traces level in leached samples by energy dispersive x-ray fluorescence technique

    International Nuclear Information System (INIS)

    Simabuco, Silvana M.; Nascimento Filho, Virgilio F. do; Inacio, Graziela R.; Navarro, Angela N.

    1996-01-01

    In landfill solid residues are disposed in the soil. When made based on technical criteria and specifically operation patterns a safe confinement is warranted according to environmental and public health protection. However, when the disposal is made by a random and unsuitable way serious problems can be caused as groundwater and superficial water contamination through leach action, indicating the usefulness of monitoring landfills. In this way energy dispersive X-ray fluorescence analysis with radioisotopic excitation was applied to evaluate the concentrations of heavy metals at trace levels in leached samples from the Americana City Landfill with pre-concentration of the elements by a non-specific precipitating agent, called ammonium pyrrolidine dithiocarbamate (APDC). (author)

  19. Celebrating variability and a call to limit systematisation: the example of the Behaviour Change Technique Taxonomy and the Behaviour Change Wheel.

    Science.gov (United States)

    Ogden, Jane

    2016-09-01

    Within any discipline there is always a degree of variability. For medicine it takes the form of Health Professional's behaviour, for education it's the style and content of the classroom, and for health psychology, it can be found in patient's behaviour, the theories used and clinical practice. Over recent years, attempts have been made to reduce this variability through the use of the Behaviour Change Technique Taxonomy, the COM-B and the Behaviour Change Wheel. This paper argues that although the call for better descriptions of what is done is useful for clarity and replication, this systematisation may be neither feasible nor desirable. In particular, it is suggested that the gaps inherent in the translational process from coding a protocol to behaviour will limit the effectiveness of reducing patient variability, that theory variability is necessary for the health and well-being of a discipline and that practice variability is central to the professional status of our practitioners. It is therefore argued that we should celebrate rather than remove this variability in order for our discipline to thrive and for us to remain as professionals rather than as technicians.

  20. Microfabricated Devices for Sample Extraction, Concentrations, and Related Sample Processing Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Gang; Lin, Yuehe

    2006-12-01

    This is an invited book chapter. As with other analytical techniques, sample pretreatments, sample extraction, sample introduction, and related techniques are of extreme importance for micro-electro-mechanical systems (MEMS). Bio-MEMS devices and systems start with a sampling step. The biological sample then usually undergoes some kinds of sample preparation steps before the actual analysis. These steps may involve extracting the target sample from its matrix, removing interferences from the sample, derivatizing the sample to detectable species, or performing a sample preconcentration step. The integration of the components for sample pretreatment into microfluidic devices represents one of the remaining the bottle-neck towards achieving true miniaturized total analysis systems (?TAS). This chapter provides a thorough state-of-art of the developments in this field to date.

  1. Callings and Organizational Behavior

    Science.gov (United States)

    Elangovan, A. R.; Pinder, Craig C.; McLean, Murdith

    2010-01-01

    Current literature on careers, social identity and meaning in work tends to understate the multiplicity, historical significance, and nuances of the concept of calling(s). In this article, we trace the evolution of the concept from its religious roots into secular realms and develop a typology of interpretations using occupation and religious…

  2. Uncertain call likelihood negatively affects sleep and next-day cognitive performance while on-call in a laboratory environment.

    Science.gov (United States)

    Sprajcer, Madeline; Jay, Sarah M; Vincent, Grace E; Vakulin, Andrew; Lack, Leon; Ferguson, Sally A

    2018-05-11

    On-call working arrangements are employed in a number of industries to manage unpredictable events, and often involve tasks that are safety- or time-critical. This study investigated the effects of call likelihood during an overnight on-call shift on self-reported pre-bed anxiety, sleep and next-day cognitive performance. A four-night laboratory-based protocol was employed, with an adaptation, a control and two counterbalanced on-call nights. On one on-call night, participants were instructed that they would definitely be called during the night, while on the other on-call night they were told they may be called. The State-Trait Anxiety Inventory form x-1 was used to investigate pre-bed anxiety, and sleep was assessed using polysomnography and power spectral analysis of the sleep electroencephalographic analysis. Cognitive performance was assessed four times daily using a 10-min psychomotor vigilance task. Participants felt more anxious before bed when they were definitely going to be called, compared with the control and maybe conditions. Conversely, participants experienced significantly less non-rapid eye movement and stage two sleep and poorer cognitive performance when told they may be called. Further, participants had significantly more rapid eye movement sleep in the maybe condition, which may be an adaptive response to the stress associated with this on-call condition. It appears that self-reported anxiety may not be linked with sleep outcomes while on-call. However, this research indicates that it is important to take call likelihood into consideration when constructing rosters and risk-management systems for on-call workers.

  3. Teknik Sampling Snowball dalam Penelitian Lapangan

    Directory of Open Access Journals (Sweden)

    Nina Nurdiani

    2014-12-01

    Full Text Available Field research can be associated with both qualitative and quantitative research methods, depending on the problems faced and the goals to be achieved. The success of data collection in the field research depends on the determination of the appropriate sampling technique, to obtain accurate data, and reliably. In studies that have problems related to specific issues, requiring a non-probability sampling techniques one of which is the snowball sampling technique. This technique is useful for finding, identifying, selecting and taking samples in a network or chain of relationships. Phased implementation procedures performed through interviews and questionnaires. Snowball sampling technique has strengths and weaknesses in its application. Field research housing sector become the case study to explain this sampling technique.

  4. Longitudinal Examination of the Bullying-Sexual Violence Pathway across Early to Late Adolescence: Implicating Homophobic Name-Calling.

    Science.gov (United States)

    Espelage, Dorothy L; Basile, Kathleen C; Leemis, Ruth W; Hipp, Tracy N; Davis, Jordan P

    2018-03-02

    The Bully-Sexual Violence Pathway theory has indicated that bullying perpetration predicts sexual violence perpetration among males and females over time in middle school, and that homophobic name-calling perpetration moderates that association among males. In this study, the Bully-Sexual Violence Pathway theory was tested across early to late adolescence. Participants included 3549 students from four Midwestern middle schools and six high schools. Surveys were administered across six time points from Spring 2008 to Spring 2013. At baseline, the sample was 32.2% White, 46.2% African American, 5.4% Hispanic, and 10.2% other. The sample was 50.2% female. The findings reveal that late middle school homophobic name-calling perpetration increased the odds of perpetrating sexual violence in high school among early middle school bullying male and female perpetrators, while homophobic name-calling victimization decreased the odds of high school sexual violence perpetration among females. The prevention of bullying and homophobic name-calling in middle school may prevent later sexual violence perpetration.

  5. Sample preparation technique for transmission electron microscopy anodized Al-Li-SiC metal matrix composite

    International Nuclear Information System (INIS)

    Shahid, M.; Thomson, G.E.

    1997-01-01

    Along with improved mechanical properties, metal matrix composites (MMC) have a disadvantage of enhanced corrosion susceptibility in aggressive environments. Recent studies on corrosion behaviour of an Al-alloy 8090/SiC MMC, revealed considerably high corrosion rates of the MMC in near neutral solutions containing chloride ions. Anodizing is one of the potential surface treatment for the MMC to provide protective coating against corrosion. The surface and cross section of the anodized MMC can easily be observed using scanning electron microscope. The anodizing behaviour of the MMC can be understood further if the anodized cross section in examined under transmission electron microscope (TEM). However, it is relatively difficult to prepare small (3 mm diameter) electron transparent specimens of the MMC supporting an anodic film. In the present study a technique has been developed for preparing thin electron transparent specimens of the anodized MMC. This technique employed conventional ion beam thinning process but the preparation of small discs was a problem. A MMMC consisting of Al-alloy 8090 with 20 % (by weight) SiC particulate with an average size of 5 Mu m, was anodized and observed in TEM after preparing the samples using the above mentioned techniques. (author)

  6. Non-destructive high-resolution thermal imaging techniques to evaluate wildlife and delicate biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Lavers, C; Franklin, P; Franklin, P; Plowman, A; Sayers, G; Bol, J; Shepard, D; Fields, D, E-mail: brnc-radarcomms1@nrta.mod.u [Sensors Team, Plymouth University at Britannia Royal Naval College, Dartmouth, Devon (United Kingdom) and Paignton Zoological Park, Paignton, Devon (United Kingdom); Thermal Wave Imaging, Inc., 845 Livernoise St, Ferndale, MI (United States); Buckfast Butterfly and Otter Sanctuary, Buckfast, Devon (United Kingdom)

    2009-07-01

    Thermal imaging cameras now allows routine monitoring of dangerous yet endangered wildlife in captivity. This study looks at the potential applications of radiometrically calibrated thermal data to wildlife, as well as providing parameters for future materials applications. We present a non-destructive active testing technique suitable for enhancing imagery contrast of thin or delicate biological specimens yielding improved thermal contrast at room temperature, for analysis of sample thermal properties. A broad spectrum of animals is studied with different textured surfaces, reflective and emissive properties in the infra red part of the electromagnetic spectrum. Some surface features offer biomimetic materials design opportunities.

  7. Non-destructive high-resolution thermal imaging techniques to evaluate wildlife and delicate biological samples

    International Nuclear Information System (INIS)

    Lavers, C; Franklin, P; Franklin, P; Plowman, A; Sayers, G; Bol, J; Shepard, D; Fields, D

    2009-01-01

    Thermal imaging cameras now allows routine monitoring of dangerous yet endangered wildlife in captivity. This study looks at the potential applications of radiometrically calibrated thermal data to wildlife, as well as providing parameters for future materials applications. We present a non-destructive active testing technique suitable for enhancing imagery contrast of thin or delicate biological specimens yielding improved thermal contrast at room temperature, for analysis of sample thermal properties. A broad spectrum of animals is studied with different textured surfaces, reflective and emissive properties in the infra red part of the electromagnetic spectrum. Some surface features offer biomimetic materials design opportunities.

  8. Endodontic pathogens causing deep neck space infections: clinical impact of different sampling techniques and antibiotic susceptibility.

    Science.gov (United States)

    Poeschl, Paul W; Crepaz, Valentina; Russmueller, Guenter; Seemann, Rudolf; Hirschl, Alexander M; Ewers, Rolf

    2011-09-01

    The aims of the present study were to compare microbial populations in patients suffering from deep neck space abscesses caused by primary endodontic infections by sampling the infections with aspiration or swabbing techniques and to determine the susceptibility rates of the isolated bacteria to commonly used antibiotics. A total of 89 patients with deep neck space abscesses caused by primary endodontic infections requiring extraoral incision and drainage under general anesthesia were included. Either aspiration or swabbing was used to sample microbial pus specimens. The culture of the microbial specimens and susceptibility testing were performed following standard procedures. A total of 142 strains were recovered from 76 patients. In 13 patients, no bacteria were found. The predominant bacteria observed were streptococci (36%), staphylococci (13%), Prevotella (8%), and Peptostreptococcus (6%). A statistically significant greater number of obligate anaerobes were found in the aspiration group. The majority of patients presented a mixed aerobic-anaerobic population of bacterial flora (62%). The antibiotic resistance rates for the predominant bacteria were 10% for penicillin G, 9% for amoxicillin, 0% for amoxicillin clavulanate, 24% for clindamycin, and 24% for erythromycin. The results of our study indicated that a greater number of anaerobes were found when sampling using the aspiration technique. Penicillin G and aminopenicillins alone are not always sufficient for the treatment of severe deep neck space abscesses; beta-lactamase inhibitor combinations are more effective. Bacteria showed significant resistant rates to clindamycin. Thus, its single use in penicillin-allergic patients has to be carefully considered. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. More Poop, More Precision: Improving Epidemiologic Surveillance of Soil-Transmitted Helminths with Multiple Fecal Sampling using the Kato-Katz Technique.

    Science.gov (United States)

    Liu, Chengfang; Lu, Louise; Zhang, Linxiu; Bai, Yu; Medina, Alexis; Rozelle, Scott; Smith, Darvin Scott; Zhou, Changhai; Zang, Wei

    2017-09-01

    Soil-transmitted helminths, or parasitic intestinal worms, are among the most prevalent and geographically widespread parasitic infections in the world. Accurate diagnosis and quantification of helminth infection are critical for informing and assessing deworming interventions. The Kato-Katz thick smear technique, the most widely used laboratory method to quantitatively assess infection prevalence and infection intensity of helminths, has often been compared with other methods. Only a few small-scale studies, however, have considered ways to improve its diagnostic sensitivity. This study, conducted among 4,985 school-age children in an area of rural China with moderate prevalence of helminth infection, examines the effect on diagnostic sensitivity of the Kato-Katz technique when two fecal samples collected over consecutive days are examined and compared with a single sample. A secondary aim was to consider cost-effectiveness by calculating an estimate of the marginal costs of obtaining an additional fecal sample. Our findings show that analysis of an additional fecal sample led to increases of 23%, 26%, and 100% for Ascaris lumbricoides, Trichuris trichiura , and hookworm prevalence, respectively. The cost of collecting a second fecal sample for our study population was approximately USD4.60 per fecal sample. Overall, the findings suggest that investing 31% more capital in fecal sample collection prevents an underestimation of prevalence by about 21%, and hence improves the diagnostic sensitivity of the Kato-Katz method. Especially in areas with light-intensity infections of soil-transmitted helminths and limited public health resources, more accurate epidemiological surveillance using multiple fecal samples will critically inform decisions regarding infection control and prevention.

  10. Dual-tip magnetic force microscopy with suppressed influence on magnetically soft samples

    International Nuclear Information System (INIS)

    Precner, Marián; Fedor, Ján; Šoltýs, Ján; Cambel, Vladimír

    2015-01-01

    Standard magnetic force microscopy (MFM) is considered as a powerful tool used for magnetic field imaging at nanoscale. The method consists of two passes realized by the magnetic tip. Within the first one, the topography pass, the magnetic tip directly touches the magnetic sample. Such contact perturbs the magnetization of the sample explored. To avoid the sample touching the magnetic tip, we present a new approach to magnetic field scanning by segregating the topological and magnetic scans with two different tips located on a cut cantilever. The approach minimizes the disturbance of sample magnetization, which could be a major problem in conventional MFM images of soft magnetic samples. By cutting the cantilever in half using the focused ion beam technique, we create one sensor with two different tips—one tip is magnetized, and the other one is left non-magnetized. The non-magnetized tip is used for topography and the magnetized one for the magnetic field imaging. The method developed we call dual-tip magnetic force microscopy (DT-MFM). We describe in detail the dual-tip fabrication process. In the experiments, we show that the DT-MFM method reduces significantly the perturbations of the magnetic tip as compared to the standard MFM method. The present technique can be used to investigate microscopic magnetic domain structures in a variety of magnetic samples and is relevant in a wide range of applications, e.g., data storage and biomedicine. (paper)

  11. Sampling technique for collection of expired COsub(2) in studies using naturally labelled sup(13)C in calves

    International Nuclear Information System (INIS)

    Chevalier, R.; Pelletier, G.; Gagnon, M.

    1984-01-01

    Natural isotopic labelling of animal metabolic processes presents great advantages over the use of artificially enriched compounds. These advantages include the use of natural diets, low cost and easiness of handling, sampling and disposal. Changes in the sup(13)C/sup(12)C ratio of expired COsub(2) after ingestion of a test meal containing a variable proportion of Csub(3) and/or Csub(4) plant-derived products permits measurements of the immediate oxidation of dietary carbohydrates. A breathing device for collection of expired COsub(2) and purification techniques are described. The breath-sampling device is composed of a polypropylene enclosure and a rubber bag. The rubber bag is blown up by the animal and a sample of the expired gas is transferred to a sampling glass holder in which a vacuum had been previously achieved. Sample purification of expired COsub(2) is done by differential freezing

  12. Vitis phylogenomics: hybridization intensities from a SNP array outperform genotype calls.

    Directory of Open Access Journals (Sweden)

    Allison J Miller

    Full Text Available Understanding relationships among species is a fundamental goal of evolutionary biology. Single nucleotide polymorphisms (SNPs identified through next generation sequencing and related technologies enable phylogeny reconstruction by providing unprecedented numbers of characters for analysis. One approach to SNP-based phylogeny reconstruction is to identify SNPs in a subset of individuals, and then to compile SNPs on an array that can be used to genotype additional samples at hundreds or thousands of sites simultaneously. Although powerful and efficient, this method is subject to ascertainment bias because applying variation discovered in a representative subset to a larger sample favors identification of SNPs with high minor allele frequencies and introduces bias against rare alleles. Here, we demonstrate that the use of hybridization intensity data, rather than genotype calls, reduces the effects of ascertainment bias. Whereas traditional SNP calls assess known variants based on diversity housed in the discovery panel, hybridization intensity data survey variation in the broader sample pool, regardless of whether those variants are present in the initial SNP discovery process. We apply SNP genotype and hybridization intensity data derived from the Vitis9kSNP array developed for grape to show the effects of ascertainment bias and to reconstruct evolutionary relationships among Vitis species. We demonstrate that phylogenies constructed using hybridization intensities suffer less from the distorting effects of ascertainment bias, and are thus more accurate than phylogenies based on genotype calls. Moreover, we reconstruct the phylogeny of the genus Vitis using hybridization data, show that North American subgenus Vitis species are monophyletic, and resolve several previously poorly known relationships among North American species. This study builds on earlier work that applied the Vitis9kSNP array to evolutionary questions within Vitis vinifera

  13. Care and calls

    DEFF Research Database (Denmark)

    Paasch, Bettina Sletten

    -centred care through the use of tactile resources and embodied orientations while they attend to the phone call. Experienced nurses Thus perform multiactivity by distributing attention towards both the patient and the phone, and the analysis shows that their concrete ways of doing so depend on the complex...... they are telephoned during interactions with patients are not universal. Indeed different strategies have evolved in other hospital departments. Not only does this thesis contribute insights into the way nurses manage phone calls during interactions with patients, but by subscribing to a growing body of embodied...... of human interaction....

  14. Innovative hybrid pile oscillator technique in the Minerve reactor: open loop vs. closed loop

    Science.gov (United States)

    Geslot, Benoit; Gruel, Adrien; Bréaud, Stéphane; Leconte, Pierre; Blaise, Patrick

    2018-01-01

    Pile oscillator techniques are powerful methods to measure small reactivity worth of isotopes of interest for nuclear data improvement. This kind of experiments has long been implemented in the Mineve experimental reactor, operated by CEA Cadarache. A hybrid technique, mixing reactivity worth estimation and measurement of small changes around test samples is presented here. It was made possible after the development of high sensitivity miniature fission chambers introduced next to the irradiation channel. A test campaign, called MAESTRO-SL, took place in 2015. Its objective was to assess the feasibility of the hybrid method and investigate the possibility to separate mixed neutron effects, such as fission/capture or scattering/capture. Experimental results are presented and discussed in this paper, which focus on comparing two measurements setups, one using a power control system (closed loop) and another one where the power is free to drift (open loop). First, it is demonstrated that open loop is equivalent to closed loop. Uncertainty management and methods reproducibility are discussed. Second, results show that measuring the flux depression around oscillated samples provides valuable information regarding partial neutron cross sections. The technique is found to be very sensitive to the capture cross section at the expense of scattering, making it very useful to measure small capture effects of highly scattering samples.

  15. On-line hydrogen-isotope measurements of organic samples using elemental chromium: An extension for high temperature elemental-analyzer techniques

    Science.gov (United States)

    Gehre, Matthias; Renpenning, Julian; Gilevska, Tetyana; Qi, Haiping; Coplen, Tyler B.; Meijer, Harro A.J.; Brand, Willi A.; Schimmelmann, Arndt

    2015-01-01

    The high temperature conversion (HTC) technique using an elemental analyzer with a glassy carbon tube and filling (temperature conversion/elemental analysis, TC/EA) is a widely used method for hydrogen isotopic analysis of water and many solid and liquid organic samples with analysis by isotope-ratio mass spectrometry (IRMS). However, the TC/EA IRMS method may produce inaccurate δ2H results, with values deviating by more than 20 mUr (milliurey = 0.001 = 1‰) from the true value for some materials. We show that a single-oven, chromium-filled elemental analyzer coupled to an IRMS substantially improves the measurement quality and reliability for hydrogen isotopic compositions of organic substances (Cr-EA method). Hot chromium maximizes the yield of molecular hydrogen in a helium carrier gas by irreversibly and quantitatively scavenging all reactive elements except hydrogen. In contrast, under TC/EA conditions, heteroelements like nitrogen or chlorine (and other halogens) can form hydrogen cyanide (HCN) or hydrogen chloride (HCl) and this can cause isotopic fractionation. The Cr-EA technique thus expands the analytical possibilities for on-line hydrogen-isotope measurements of organic samples significantly. This method yielded reproducibility values (1-sigma) for δ2H measurements on water and caffeine samples of better than 1.0 and 0.5 mUr, respectively. To overcome handling problems with water as the principal calibration anchor for hydrogen isotopic measurements, we have employed an effective and simple strategy using reference waters or other liquids sealed in silver-tube segments. These crimped silver tubes can be employed in both the Cr-EA and TC/EA techniques. They simplify considerably the normalization of hydrogen-isotope measurement data to the VSMOW-SLAP (Vienna Standard Mean Ocean Water-Standard Light Antarctic Precipitation) scale, and their use improves accuracy of the data by eliminating evaporative loss and associated isotopic fractionation while

  16. On-line hydrogen-isotope measurements of organic samples using elemental chromium: an extension for high temperature elemental-analyzer techniques.

    Science.gov (United States)

    Gehre, Matthias; Renpenning, Julian; Gilevska, Tetyana; Qi, Haiping; Coplen, Tyler B; Meijer, Harro A J; Brand, Willi A; Schimmelmann, Arndt

    2015-01-01

    The high temperature conversion (HTC) technique using an elemental analyzer with a glassy carbon tube and filling (temperature conversion/elemental analysis, TC/EA) is a widely used method for hydrogen isotopic analysis of water and many solid and liquid organic samples with analysis by isotope-ratio mass spectrometry (IRMS). However, the TC/EA IRMS method may produce inaccurate δ(2)H results, with values deviating by more than 20 mUr (milliurey = 0.001 = 1‰) from the true value for some materials. We show that a single-oven, chromium-filled elemental analyzer coupled to an IRMS substantially improves the measurement quality and reliability for hydrogen isotopic compositions of organic substances (Cr-EA method). Hot chromium maximizes the yield of molecular hydrogen in a helium carrier gas by irreversibly and quantitatively scavenging all reactive elements except hydrogen. In contrast, under TC/EA conditions, heteroelements like nitrogen or chlorine (and other halogens) can form hydrogen cyanide (HCN) or hydrogen chloride (HCl) and this can cause isotopic fractionation. The Cr-EA technique thus expands the analytical possibilities for on-line hydrogen-isotope measurements of organic samples significantly. This method yielded reproducibility values (1-sigma) for δ(2)H measurements on water and caffeine samples of better than 1.0 and 0.5 mUr, respectively. To overcome handling problems with water as the principal calibration anchor for hydrogen isotopic measurements, we have employed an effective and simple strategy using reference waters or other liquids sealed in silver-tube segments. These crimped silver tubes can be employed in both the Cr-EA and TC/EA techniques. They simplify considerably the normalization of hydrogen-isotope measurement data to the VSMOW-SLAP (Vienna Standard Mean Ocean Water-Standard Light Antarctic Precipitation) scale, and their use improves accuracy of the data by eliminating evaporative loss and associated isotopic fractionation while

  17. Martian regolith geochemistry and sampling techniques

    Science.gov (United States)

    Clark, B. C.

    Laboratory study of samples of the intermediate and fine-grained regolith, including duricrust peds, is a fundamental prerequisite for understanding the types of physical and chemical weathering processes on Mars. The extraordinary importance of such samples is their relevance to understanding past changes in climate, availability (and possible physical state) of water, eolian forces, the thermal and chemical influences of volcanic and impact processes, and the inventory and fates of Martian volatiles. Fortunately, this regolith material appears to be ubiquitous over the Martian surface, and should be available at many different landing sites. Viking data has been interpreted to indicate a smectite-rich regolith material, implying extensive weathering involving aqueous activity and geochemical alteration. An all-igneous source of the Martian fines has also been proposed. The X-ray fluorescence measurement data set can now be fully explained in terms of a simple two-component model. The first component is silicate, having strong geochemical similarities with Shergottites, but not other SNC meteorites. The second component is salt. Variations in these components could produce silicate and salt-rich beds, the latter being of high potential importance for microenvironments in which liquid water (brines) could exist. It therefore would be desirable to scan the surface of the regolith for such prospects.

  18. Martian regolith geochemistry and sampling techniques

    Science.gov (United States)

    Clark, B. C.

    1988-01-01

    Laboratory study of samples of the intermediate and fine-grained regolith, including duricrust peds, is a fundamental prerequisite for understanding the types of physical and chemical weathering processes on Mars. The extraordinary importance of such samples is their relevance to understanding past changes in climate, availability (and possible physical state) of water, eolian forces, the thermal and chemical influences of volcanic and impact processes, and the inventory and fates of Martian volatiles. Fortunately, this regolith material appears to be ubiquitous over the Martian surface, and should be available at many different landing sites. Viking data has been interpreted to indicate a smectite-rich regolith material, implying extensive weathering involving aqueous activity and geochemical alteration. An all-igneous source of the Martian fines has also been proposed. The X-ray fluorescence measurement data set can now be fully explained in terms of a simple two-component model. The first component is silicate, having strong geochemical similarities with Shergottites, but not other SNC meteorites. The second component is salt. Variations in these components could produce silicate and salt-rich beds, the latter being of high potential importance for microenvironments in which liquid water (brines) could exist. It therefore would be desirable to scan the surface of the regolith for such prospects.

  19. Bat calls while preying: A method for reconstructing the signal emitted by a directional sound source

    DEFF Research Database (Denmark)

    Guarato, Francesco; Hallam, John

    2010-01-01

    Understanding and modeling bat biosonar behavior should take into account what the bat actually emitted while exploring the surrounding environment. Recording of the bat calls could be performed by means of a telemetry system small enough to sit on the bat head, though filtering due to bat...... directivity affects recordings and not all bat species are able to carry such a device. Instead, remote microphone recordings of the bat calls could be processed by means of a mathematical method that estimates bat head orientation as a first step before calculating the amplitudes of each call for each...... and discussed. A further improvement of the method is necessary as its performance for call reconstruction strongly depends on correct choice of the sample at which the recorded call is thought to start in each microphone data set....

  20. TCP-Call Admission Control Interaction in Multiplatform Space Architectures

    Directory of Open Access Journals (Sweden)

    Georgios Theodoridis

    2007-06-01

    Full Text Available The implementation of efficient call admission control (CAC algorithms is useful to prevent congestion and guarantee target quality of service (QoS. When TCP protocol is adopted, some inefficiencies can arise due to the peculiar evolution of the congestion window. The development of cross-layer techniques can greatly help to improve efficiency and flexibility for wireless networks. In this frame, the present paper addresses the introduction of TCP feedback into the CAC procedures in different nonterrestrial wireless architectures. CAC performance improvement is shown for different space-based architectures, including both satellites and high altitude platform (HAP systems.

  1. TCP-Call Admission Control Interaction in Multiplatform Space Architectures

    Directory of Open Access Journals (Sweden)

    Roseti Cesare

    2007-01-01

    Full Text Available The implementation of efficient call admission control (CAC algorithms is useful to prevent congestion and guarantee target quality of service (QoS. When TCP protocol is adopted, some inefficiencies can arise due to the peculiar evolution of the congestion window. The development of cross-layer techniques can greatly help to improve efficiency and flexibility for wireless networks. In this frame, the present paper addresses the introduction of TCP feedback into the CAC procedures in different nonterrestrial wireless architectures. CAC performance improvement is shown for different space-based architectures, including both satellites and high altitude platform (HAP systems.

  2. Whole arm manipulation planning based on feedback velocity fields and sampling-based techniques.

    Science.gov (United States)

    Talaei, B; Abdollahi, F; Talebi, H A; Omidi Karkani, E

    2013-09-01

    Changing the configuration of a cooperative whole arm manipulator is not easy while enclosing an object. This difficulty is mainly because of risk of jamming caused by kinematic constraints. To reduce this risk, this paper proposes a feedback manipulation planning algorithm that takes grasp kinematics into account. The idea is based on a vector field that imposes perturbation in object motion inducing directions when the movement is considerably along manipulator redundant directions. Obstacle avoidance problem is then considered by combining the algorithm with sampling-based techniques. As experimental results confirm, the proposed algorithm is effective in avoiding jamming as well as obstacles for a 6-DOF dual arm whole arm manipulator. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  3. Yield strength, shear stress and toughness of YBCO samples textured by Bridgman technique

    International Nuclear Information System (INIS)

    Roa, J J; Capdevila, X G; Martinez, M; Segarra, M; Jimenez-Pique, E

    2008-01-01

    Mechanical properties of the orthorhombic phase of YBa 2 Cu 3 O 7-δ (Y-123) at room temperature have been investigated at different applied loads using nanoindentation technique. The study was carried out for several monodomains on the (001) planes for textured Bridgman samples with dispersed Y 2 BaCuO 5 (Y-211) particles as pinning centers. The yield strength (σ ys ), shear stress (τ m ) and toughness (K IC ) of Y123/Y211composite was determined at different applied loads. First and second mechanical properties have been calculated though the Hertz equations and the last one with Lawn et al. equations. Finally, the ultra-low imprints obtained by nanoindentation have been correlated with parameters obtained by Field Emission Scanning Electron Microscope (FE-SEM)

  4. Evaluation of dry blood spot technique for quantification of an Anti-CD20 monoclonal antibody drug in human blood samples.

    Science.gov (United States)

    Lin, Yong-Qing; Zhang, Yilu; Li, Connie; Li, Louis; Zhang, Kelley; Li, Shawn

    2012-01-01

    To evaluate the dried blood spot (DBS) technique in ELISA quantification of larger biomolecular drugs, an anti-CD20 monoclonal antibody drug was used as an example. A method for the quantification of the anti-CD20 drug in human DBS was developed and validated. The drug standard and quality control samples prepared in fresh human blood were spotted on DBS cards and then extracted. A luminescent ELISA was used for quantification of the drug from DBS samples. The assay range of the anti-CD20 drug standards in DBS was 100-2500ng/mL. The intra-assay precision (%CV) ranged from 0.4% to 10.1%, and the accuracy (%Recovery) ranged from 77.9% to 113.9%. The inter assay precision (%CV) ranged from 5.9% to 17.4%, and the accuracy ranged from 81.5% to 110.5%. The DBS samples diluted 500 and 50-fold yielded recovery of 88.7% and 90.7%, respectively. The preparation of DBS in higher and lower hematocrit (53% and 35%) conditions did not affect the recovery of the drug. Furthermore, the storage stability of the anti-CD20 drug on DBS cards was tested at various conditions. It was found that the anti-CD20 drug was stable for one week in DBS stored at room temperature. However, it was determined that the stability was compro]mised in DBS stored at high humidity, high temperature (55°C), and exposed to direct daylight for a week, as well as for samples stored at room temperature and high humidity conditions for a month. Stability did not change significantly in samples that underwent 3 freeze/thaw cycles. Our results demonstrated a successful use of DBS technique in ELISA quantification of an anti-CD20 monoclonal antibody drug in human blood. The stability data provides information regarding sample storage and shipping for future clinical studies. It is, therefore, concluded that the DBS technique is applicable in the quantification of other large biomolecule drugs or biomarkers. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Study of uranium mineralization in rock samples from marwat range bannu basin by fission track analysis technique

    International Nuclear Information System (INIS)

    Qureshi, A.Z.; Ullah, K.; Ullah, N.; Akram, M.

    2004-07-01

    The Geophysics Division, Atomic Energy Minerals Centre (AEMC), Lahore has planned a uranium exploration program in Marwat Range, Bannu Basin. In this connection 30 thin sections of rock samples, collected from four areas; namely, Darra Tang, Simukili, Karkanwal and Sheikhillah from Marwat Range, and one from Salt Range were provided to Nuclear Geology Group of Physics Research Division, PINSTECH for the study of nature and mechanism of uranium mineralization These studies are aimed to help in designing uranium exploration strategy by providing the loci of uranium sources in the Marwat and Salt Ranges. The samples have been studied using fission track analysis technique. (author)

  6. Direct Trace Element Analysis of Liquid Blood Samples by In-Air Ion Beam Analytical Techniques (PIXE-PIGE).

    Science.gov (United States)

    Huszank, Robert; Csedreki, László; Török, Zsófia

    2017-02-07

    There are various liquid materials whose elemental composition is of interest in various fields of science and technology. In many cases, sample preparation or the extraction can be complicated, or it would destroy the original environment before the analysis (for example, in the case of biological samples). However, multielement direct analysis of liquid samples can be realized by an external PIXE-PIGE measurement system. Particle-induced X-ray and gamma-ray emission spectroscopy (PIXE, PIGE) techniques were applied in external (in-air) microbeam configuration for the trace and main element determination of liquid samples. The direct analysis of standard solutions of several metal salts and human blood samples (whole blood, blood serum, blood plasma, and formed elements) was realized. From the blood samples, Na, P, S, Cl, K, Ca, Fe, Cu, Zn, and Br elemental concentrations were determined. The focused and scanned ion beam creates an opportunity to analyze very small volume samples (∼10 μL). As the sample matrix consists of light elements, the analysis is possible at ppm level. Using this external beam setup, it was found that it is possible to determine elemental composition of small-volume liquid samples routinely, while the liquid samples do not require any preparation processes, and thus, they can be analyzed directly. In the case of lower concentrations, the method is also suitable for the analysis (down to even ∼1 ppm level) but with less accuracy and longer measurement times.

  7. SLIM-MAUD - a computer based technique for human reliability assessment

    International Nuclear Information System (INIS)

    Embrey, D.E.

    1985-01-01

    The Success Likelihood Index Methodology (SLIM) is a widely applicable technique which can be used to assess human error probabilities in both proceduralized and cognitive tasks (i.e. those involving decision making, problem solving, etc.). It assumes that expert assessors are able to evaluate the relative importance (or weights) of different factors called Performance Shaping Factors (PSFs), in determining the likelihood of error for the situations being assessed. Typical PSFs are the extent to which good procedures are available, operators are adequately trained, the man-machine interface is well designed, etc. If numerical ratings are made of the PSFs for the specific tasks being evaluated, these can be combined with the weights to give a numerical index, called the Success Likelihood Index (SLI). The SLI represents, in numerical form, the overall assessment of the experts of the likelihood of task success. The SLI can be subsequently transformed to a corresponding human error probability (HEP) estimate. The latest form of the SLIM technique is implemented using a microcomputer based system called MAUD (Multi-Attribute Utility Decomposition), the resulting technique being called SLIM-MAUD. A detailed description of the SLIM-MAUD technique and case studies of applications are available. An illustrative example of the application of SLIM-MAUD in probabilistic risk assessment is given

  8. Macro elemental analysis of food samples by nuclear analytical technique

    Science.gov (United States)

    Syahfitri, W. Y. N.; Kurniawati, S.; Adventini, N.; Damastuti, E.; Lestiani, D. D.

    2017-06-01

    Energy-dispersive X-ray fluorescence (EDXRF) spectrometry is a non-destructive, rapid, multi elemental, accurate, and environment friendly analysis compared with other detection methods. Thus, EDXRF spectrometry is applicable for food inspection. The macro elements calcium and potassium constitute important nutrients required by the human body for optimal physiological functions. Therefore, the determination of Ca and K content in various foods needs to be done. The aim of this work is to demonstrate the applicability of EDXRF for food analysis. The analytical performance of non-destructive EDXRF was compared with other analytical techniques; neutron activation analysis and atomic absorption spectrometry. Comparison of methods performed as cross checking results of the analysis and to overcome the limitations of the three methods. Analysis results showed that Ca found in food using EDXRF and AAS were not significantly different with p-value 0.9687, whereas p-value of K between EDXRF and NAA is 0.6575. The correlation between those results was also examined. The Pearson correlations for Ca and K were 0.9871 and 0.9558, respectively. Method validation using SRM NIST 1548a Typical Diet was also applied. The results showed good agreement between methods; therefore EDXRF method can be used as an alternative method for the determination of Ca and K in food samples.

  9. An intercomparison of sampling techniques among five European laboratories for measurements of radiocaesium in upland pasture and soil

    International Nuclear Information System (INIS)

    Nielsen, S.P.; Aarkrog, A.; Colgan, P.A.; McGee, E.; Synnott, H.J.; Johansson, K.J.; Horrill, A.D.; Kennedy, V.H.; Barbayiannis, N.

    1992-02-01

    An intercomparison of sampling procedures used by five European laboratories for the determination of radiocaesium in vegetation and peaty soil was carried out at two locations in Cumbria. The soil sampling procedures included th ecollection of depth profiles in order to obtain information on the vertical distribution of radiocaesium in addition to the total deposition. The number of samples taken by each laboratory varied from one to five. The multiple sampling has given information on the homogeneity of the parameters studied at each location. The parameters comprise soil bulk densities, total deposition of 137 Cs, deposition of 137 Cs in three soil layers, biomass densities, concentrations of 137 Cs in pasture, and activity ratios ( 134 Cs/ 137 Cs) in soil and vegetation. The determination of total deposition of 137 Cs gave no indication of differences between the laboratories. The total depositions of 134 Cs and 137 Cs observed at one site were compared with levels obtained from another study and the two sets of data were found to be in good agreement. The results from the soil profiles do indicate significant differences between laboratories. This covers the vertical distributions of 137 Cs deposition including the 134 Cs/ 137 Cs-activity ratios as well as the soil bulk densities. One laboratory using a coring technique observed difficulties during sampling due to compression of the soil. The coring technique should thus be avoided or applied with extreme care for the sampling of depth profiles in peaty soil. The results from the sampling of pasture show no indication of differences between the laboratories. For the parameters studied the observed variabilities across soil depths and locations range from 10% to 82% in terms of relative standard deviations. A comparison across all results at the two locations indicate a 50% higher field variability at one of the sites relative to the other. (au) (24 tabs., 9 ills., 3 refs.)

  10. Psychological capital, work engagement and organisational commitment amongst call centre employees in South Africa

    Directory of Open Access Journals (Sweden)

    Janet C. Simons

    2013-11-01

    Research purpose: The purpose of the research was to determine the relationship between psychological capital, work engagement and organisational commitment amongst call centre employees; and further, to determine whether psychological capital and work engagement hold predictive value for the organisational commitment of call centre employees. Motivation for the study: There is a gap in research in understanding and enabling positive resource capacities in highly stressful work contexts such as call centres. Research design, approach and method: A cross-sectional survey design was used. A sample of 106 call centre employees from a South African organisation participated in the research. The measuring instruments included a demographic questionnaire, the Psychological Capital Questionnaire (PCQ, the Utrecht Work Engagement Scale (UWES and the Organisational Commitment Questionnaire (OCQ. Main findings: Significant positive relationships were found between psychological capital, work engagement and organisational commitment. The results showed work engagement as being the only significant predictor of organisational commitment. Practical/managerial implications: Call centre employers need to develop and implement workplace interventions that would increase the psychological capital of call centre employees. Contribution/value-add: The research findings will benefit both call centre employees and management. The study highlighted the importance of the role of optimism as a subdimension of psychological capital in developing work engagement and organisational commitment amongst call centre employees.

  11. XRF and TXRF techniques for multi-element determination of trace elements in whole blood and human hair samples

    International Nuclear Information System (INIS)

    Khuder, A.; Karjou, J.; Sawan, M.Kh.; Bakir, M.A.

    2007-01-01

    XRF and TXRF were established as useful techniques for multi-element analysis of whole blood and human head hair samples. Direct-XRF with different collimation units and different X-ray excitation modes was successfully used for the determination of S, P, K, Ca, Fe, and Br elements in blood samples and K, Ca, Mn, Fe elements in human hair samples. Direct analysis by TXRF was used for the determination of Rb and Sr in digested blood and human hair samples, respectively, while, the co-precipitation method using APDC for TXRF analysis was used for the determination of Ni, Cu, Zn, and Pb elements in both matrices. As a result, the improved XRF and TXRF methods were applied for multi-element determination of elements in whole blood and human hair samples in non-occupational exposed population living in Damascus city. The mean concentrations of analyzed elements in both matrices were on the reported range values for non-occupational population in other countries. (author)

  12. XRF and TXRF techniques for multi-element determination of trace elements in whole blood and human hair samples

    International Nuclear Information System (INIS)

    Khuder, A.; Karjou, J.; Sawan, M.Kh.; Bakir, M.A.

    2008-01-01

    XRF and TXRF were established as useful techniques for multi-element analysis of whole blood and human head hair samples. Direct-XRF with different collimation units and different X-ray excitation modes was successfully used for the determination of S, P, K, Ca, Fe, and Br elements in blood samples and K, Ca, Mn, Fe elements in human hair samples. Direct analysis by TXRF was used for the determination of Rb and Sr in digested blood and human hair samples, respectively, while, the co-precipitation method using APDC for TXRF analysis was used for the determination of Ni, Cu, Zn, and Pb elements in both matrices. As a result, the improved XRF and TXRF methods were applied for multi-element determination of elements in whole blood and human hair samples in non-occupational exposed population living in Damascus city. The mean concentrations of analyzed elements in both matrices were on the reported range values for non-occupational population in other countries. (author)

  13. How to call the Fire Brigade

    CERN Multimedia

    2003-01-01

    The telephone numbers for the CERN Fire Brigade are: 74444 for emergency calls 74848 for other calls Note The number 112 will stay in use for emergency calls from "wired" telephones, however, from mobile phones it leads to non-CERN emergency services.

  14. Seven-hour fluorescence in situ hybridization technique for enumeration of Enterobacteriaceae in food and environmental water sample.

    Science.gov (United States)

    Ootsubo, M; Shimizu, T; Tanaka, R; Sawabe, T; Tajima, K; Ezura, Y

    2003-01-01

    A fluorescent in situ hybridization (FISH) technique using an Enterobacteriaceae-specific probe (probe D) to target 16S rRNA was improved in order to enumerate, within a single working day, Enterobacteriaceae present in food and environmental water samples. In order to minimize the time required for the FISH procedure, each step of FISH with probe D was re-evaluated using cultured Escherichia coli. Five minutes of ethanol treatment for cell fixation and hybridization were sufficient to visualize cultured E. coli, and FISH could be performed within 1 h. Because of the difficulties in detecting low levels of bacterial cells by FISH without cultivation, a FISH technique for detecting microcolonies on membrane filters was investigated to improve the bacterial detection limit. FISH with probe D following 6 h of cultivation to grow microcolonies on a 13 mm diameter membrane filter was performed, and whole Enterobacteriaceae microcolonies on the filter were then detected and enumerated by manual epifluorescence microscopic scanning at magnification of x100 in ca 5 min. The total time for FISH with probe D following cultivation (FISHFC) was reduced to within 7 h. FISHFC can be applied to enumerate cultivable Enterobacteriaceae in food (above 100 cells g-1) and environmental water samples (above 1 cell ml-1). Cultivable Enterobacteriaceae in food and water samples were enumerated accurately within 7 h using the FISHFC method. A FISHFC method capable of evaluating Enterobacteriaceae contamination in food and environmental water within a single working day was developed.

  15. MUP, CEC-DES, STRADE. Codes for uncertainty propagation, experimental design and stratified random sampling techniques

    International Nuclear Information System (INIS)

    Amendola, A.; Astolfi, M.; Lisanti, B.

    1983-01-01

    The report describes the how-to-use of the codes: MUP (Monte Carlo Uncertainty Propagation) for uncertainty analysis by Monte Carlo simulation, including correlation analysis, extreme value identification and study of selected ranges of the variable space; CEC-DES (Central Composite Design) for building experimental matrices according to the requirements of Central Composite and Factorial Experimental Designs; and, STRADE (Stratified Random Design) for experimental designs based on the Latin Hypercube Sampling Techniques. Application fields, of the codes are probabilistic risk assessment, experimental design, sensitivity analysis and system identification problems

  16. Petrosal sinus sampling: technique and rationale.

    Science.gov (United States)

    Miller, D L; Doppman, J L

    1991-01-01

    Bilateral simultaneous sampling of the inferior petrosal sinuses is an extremely sensitive, specific, and accurate test for diagnosing Cushing disease and distinguishing between that entity and the ectopic ACTH syndrome. It is also valuable for lateralizing small hormone-producing adenomas within the pituitary gland. The inferior petrosal sinuses connect the cavernous sinuses with the ipsilateral internal jugular veins. The anatomy of the anastomoses between the inferior petrosal sinus, the internal jugular vein, and the venous plexuses at the base of the skull varies, but it is almost always possible to catheterize the inferior petrosal sinus. In addition, variations in size and anatomy are often present between the two inferior petrosal sinuses in a patient. Advance preparation is required for petrosal sinus sampling. Teamwork is a critical element, and each member of the staff should know what he or she will be doing during the procedure. The samples must be properly labeled, processed, and stored. Specific needles, guide wires, and catheters are recommended for this procedure. The procedure is performed with specific attention to the three areas of potential technical difficulty: catheterization of the common femoral veins, crossing the valve at the base of the left internal jugular vein, and selective catheterization of the inferior petrosal sinuses. There are specific methods for dealing with each of these areas. The sine qua non of correct catheter position in the inferior petrosal sinus is demonstration of reflux of contrast material into the ipsilateral cavernous sinus. Images must always be obtained to document correct catheter position. Special attention must be paid to two points to prevent potential complications: The patient must be given an adequate dose of heparin, and injection of contrast material into the inferior petrosal sinuses and surrounding veins must be done gently and carefully. When the procedure is performed as outlined, both inferior

  17. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    Directory of Open Access Journals (Sweden)

    Helena Prosen

    2014-05-01

    Full Text Available Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc. published in the last decade. Several innovative liquid-phase microextraction (LPME techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME, hollow fiber-liquid phase microextraction (HF-LPME, dispersive liquid-liquid microextraction (DLLME. Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  18. Applications of liquid-phase microextraction in the sample preparation of environmental solid samples.

    Science.gov (United States)

    Prosen, Helena

    2014-05-23

    Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc.) published in the last decade. Several innovative liquid-phase microextraction (LPME) techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME). Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  19. Product-selective blot: a technique for measuring enzyme activities in large numbers of samples and in native electrophoresis gels

    International Nuclear Information System (INIS)

    Thompson, G.A.; Davies, H.M.; McDonald, N.

    1985-01-01

    A method termed product-selective blotting has been developed for screening large numbers of samples for enzyme activity. The technique is particularly well suited to detection of enzymes in native electrophoresis gels. The principle of the method was demonstrated by blotting samples from glutaminase or glutamate synthase reactions into an agarose gel embedded with ion-exchange resin under conditions favoring binding of product (glutamate) over substrates and other substances in the reaction mixture. After washes to remove these unbound substances, the product was measured using either fluorometric staining or radiometric techniques. Glutaminase activity in native electrophoresis gels was visualized by a related procedure in which substrates and products from reactions run in the electrophoresis gel were blotted directly into a resin-containing image gel. Considering the selective-binding materials available for use in the image gel, along with the possible detection systems, this method has potentially broad application

  20. Microwave Heating of Synthetic Skin Samples for Potential Treatment of Gout Using the Metal-Assisted and Microwave-Accelerated Decrystallization Technique

    OpenAIRE

    Toker, Salih; Boone-Kukoyi, Zainab; Thompson, Nishone; Ajifa, Hillary; Clement, Travis; Ozturk, Birol; Aslan, Kadir

    2016-01-01

    Physical stability of synthetic skin samples during their exposure to microwave heating was investigated to demonstrate the use of the metal-assisted and microwave-accelerated decrystallization (MAMAD) technique for potential biomedical applications. In this regard, optical microscopy and temperature measurements were employed for the qualitative and quantitative assessment of damage to synthetic skin samples during 20 s intermittent microwave heating using a monomode microwave source (at 8 G...

  1. Using Semantic Similarity In Automated Call Quality Evaluator For Call Centers

    Directory of Open Access Journals (Sweden)

    Ria A. Sagum

    2015-08-01

    Full Text Available Conversation between the agent and client are being evaluated manually by a quality assurance officer QA. This job is only one of the responsibilities being done by a QA and particularly eat ups a lot of time for them which lead to late evaluation results that may cause untimely response of the company to concerns raised by their clients. This research developed an application software that automates and evaluates the quality assurance in business process outsourcing companies or customer service management implementing sentence similarity. The developed system includes two modules speaker diarization which includes transcription and question and answer extraction and similarity checker which checks the similarity between the extracted answer and the answer of the call center agent to a question. The system was evaluated for Correctness of the extracted answers and accurateness of the evaluation for a particular call. Audio conversations were tested for the accuracy of the transcription module which has an accuracy of 27.96. The Precision Recall and F-measure of the extracted answer was tested as 78.03 96.26 and 86.19 respectively. The Accuracy of the system in evaluating a call is 70.

  2. Determination of organically bound Tritium in environmental samples by application of the oxidizing plasma technique

    International Nuclear Information System (INIS)

    Strack, S.; Koenig, L.A.

    1981-12-01

    The low-temperature oxidizing plasma technique with a suitable system for trapping the water formed in the oxidation process can be used to determine T bound organically in low-level samples. First, the samples are freeze-dried and the tissue water obtained in this way is measured, after distillation, in a liquid scintillation spectrometer. The residual dry matter is ashed in the reactor chamber of the plasma system. Oxidation takes place at temperatures not exceeding 200 0 C in an oxygen flow of about 40 ml/min. The water of oxidation is collected in a cold trap installed behind the reactor chamber. A volume of about 10 ml of water is sufficient to measure the tritium activity without enrichment. The oxidation behavior of various organic materials has been tested. Some first results of T concentrations in tissue water and the organic dry matter from food and plant samples collected in the vicinity of the Nuclear Research Center are presented. The method has the advantage that a commercially available instrument can be used requiring only little additional equipment. Handling is much less dangerous and contamination effects by atmospheric T can be easily kept at a minimum. (orig./HP) [de

  3. General principles governing sampling and measurement techniques for monitoring radioactive effluents from nuclear facilities

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1978-01-01

    An explanation is given of the need to monitor the release of radioactive gases and liquid effluents from nuclear facilities, with particular emphasis on the ICRP recommendations and on the interest in this problem shown by the larger international organizations. This is followed by a description of the classes of radionuclides that are normally monitored in this way. The characteristics of monitoring 'in line' and 'by sample taking' are described; the disadvantages of in line monitoring and the problem of sample representativity are discussed. There follows an account of the general principles for measuring gaseous and liquid effluents that are applied in the techniques normally employed at nuclear facilities. Standards relating to the specifications for monitoring instruments are at present being devised by the International Electrotechnical Commission, and there are still major differences in national practices, at least as far as measurement thresholds are concerned. In conclusion, it is shown that harmonization of practices and standardization of equipment would probably help to make international relations in the field more productive. (author)

  4. The alkali halide disk technique in infra-red spectrometry : Anomalous behaviour of some samples dispersed in alkali halide disks

    NARCIS (Netherlands)

    Tolk, A.

    1961-01-01

    Some difficulties encountered in the application of the alkali halide disk technique in infra-red spectrometry are discussed. Complications due to interaction of the sample with the alkali halide have been studied experimentally. It was found that the anomalous behaviour of benzoic acid, succinic

  5. Calling in Work: Secular or Sacred?

    Science.gov (United States)

    Steger, Michael F.; Pickering, N. K.; Shin, J. Y.; Dik, B. J.

    2010-01-01

    Recent scholarship indicates that people who view their work as a calling are more satisfied with their work and their lives. Historically, calling has been regarded as a religious experience, although modern researchers frequently have adopted a more expansive and secular conceptualization of calling, emphasizing meaning and personal fulfillment…

  6. Occupational voice demands and their impact on the call-centre industry

    Directory of Open Access Journals (Sweden)

    Duffy OM

    2009-04-01

    Full Text Available Abstract Background Within the last decade there has been a growth in the call-centre industry in the UK, with a growing awareness of the voice as an important tool for successful communication. Occupational voice problems such as occupational dysphonia, in a business which relies on healthy, effective voice as the primary professional communication tool, may threaten working ability and occupational health and safety of workers. While previous studies of telephone call-agents have reported a range of voice symptoms and functional vocal health problems, there have been no studies investigating the use and impact of vocal performance in the communication industry within the UK. This study aims to address a significant gap in the evidence-base of occupational health and safety research. The objectives of the study are: 1. to investigate the work context and vocal communication demands for call-agents; 2. to evaluate call-agents' vocal health, awareness and performance; and 3. to identify key risks and training needs for employees and employers within call-centres. Methods and design This is an occupational epidemiological study, which plans to recruit call-centres throughout the UK and Ireland. Data collection will consist of three components: 1. interviews with managers from each participating call-centre to assess their communication and training needs; 2. an online biopsychosocial questionnaire will be administered to investigate the work environment and vocal demands of call-agents; and 3. voice acoustic measurements of a random sample of participants using the Multi-dimensional Voice Program (MDVP. Qualitative content analysis from the interviews will identify underlying themes and issues. A multivariate analysis approach will be adopted using Structural Equation Modelling (SEM, to develop voice measurement models in determining the construct validity of potential factors contributing to occupational dysphonia. Quantitative data will be

  7. Thermal Characterization of Edible Oils by Using Photopyroelectric Technique

    Science.gov (United States)

    Lara-Hernández, G.; Suaste-Gómez, E.; Cruz-Orea, A.; Mendoza-Alvarez, J. G.; Sánchez-Sinéncio, F.; Valcárcel, J. P.; García-Quiroz, A.

    2013-05-01

    Thermal properties of several edible oils such as olive, sesame, and grape seed oils were obtained by using the photopyroelectric technique. The inverse photopyroelectric configuration was used in order to obtain the thermal effusivity of the oil samples. The theoretical equation for the photopyroelectric signal in this configuration, as a function of the incident light modulation frequency, was fitted to the experimental data in order to obtain the thermal effusivity of these samples. Also, the back photopyroelectric configuration was used to obtain the thermal diffusivity of these oils; this thermal parameter was obtained by fitting the theoretical equation for this configuration, as a function of the sample thickness (called the thermal wave resonator cavity), to the experimental data. All measurements were done at room temperature. A complete thermal characterization of these edible oils was achieved by the relationship between the obtained thermal diffusivities and thermal effusivities with their thermal conductivities and volumetric heat capacities. The obtained results are in agreement with the thermal properties reported for the case of the olive oil.

  8. Sampling Polya-Gamma random variates: alternate and approximate techniques

    OpenAIRE

    Windle, Jesse; Polson, Nicholas G.; Scott, James G.

    2014-01-01

    Efficiently sampling from the P\\'olya-Gamma distribution, ${PG}(b,z)$, is an essential element of P\\'olya-Gamma data augmentation. Polson et. al (2013) show how to efficiently sample from the ${PG}(1,z)$ distribution. We build two new samplers that offer improved performance when sampling from the ${PG}(b,z)$ distribution and $b$ is not unity.

  9. Hornbills can distinguish between primate alarm calls.

    Science.gov (United States)

    Rainey, Hugo J.; Zuberbühler, Klaus; Slater, Peter J. B.

    2004-01-01

    Some mammals distinguish between and respond appropriately to the alarm calls of other mammal and bird species. However, the ability of birds to distinguish between mammal alarm calls has not been investigated. Diana monkeys (Cercopithecus diana) produce different alarm calls to two predators: crowned eagles (Stephanoaetus coronatus) and leopards (Panthera pardus). Yellow-casqued hornbills (Ceratogymna elata) are vulnerable to predation by crowned eagles but are not preyed on by leopards and might therefore be expected to respond to the Diana monkey eagle alarm call but not to the leopard alarm call. We compared responses of hornbills to playback of eagle shrieks, leopard growls, Diana monkey eagle alarm calls and Diana monkey leopard alarm calls and found that they distinguished appropriately between the two predator vocalizations as well as between the two Diana monkey alarm calls. We discuss possible mechanisms leading to these responses. PMID:15209110

  10. Comparative study of modern extraction techniques for the determination of environmental samples (M14)

    International Nuclear Information System (INIS)

    Gfrerer, M.; Lankmayr, E.

    2002-01-01

    Full text: The aim of any extraction method in analytical chemistry is, to effectively separate the analytes from the matrix. The whole step should be fast and quantitative with minimal solvent and time required. The classical Soxhlet extraction usually requires large volumes (up to 200 ml) of solvent to be refluxed through the solid samples for several hours. Therefore, in the last decades, alternatives for this extraction method have been presented and investigated such as ultrasonic extraction (UE), supercritical fluid extraction (SFE), accelerated solvent extraction (ASE), microwave-assisted extraction (MAE) and fluidized-bed extraction (FBE). The actual choice for analytical application is frequently the initial capital cost, operating costs, simplicity of operation, amount of organic solvent required and sample throughput. Since sample preparation is a critical step in the analytical cycle, special care has to be taken for an accurate choice and optimization of extraction techniques and clean-up procedures. Therefore, MAE and FBE were investigated for their influential extraction parameters and these parameters were optimized for the extraction of organochlorine biocides, polychlorinated biphenyls and polycyclic aromatic hydrocarbons from environmental matrices like soil, sediment and sewage sludge. The extraction yields were compared with those obtained by Soxhlet extraction performed following DIN-methods. Finally, the optimized modern methods were validated by systematic experiments with certified reference materials. Refs. 3 (author)

  11. The use of ICP-MS and LA-ICP-MS techniques for uranium analysis in real-life swipe samples for safeguards purposes

    Energy Technology Data Exchange (ETDEWEB)

    Pestana, Rafael C.B.; Sarkis, Jorge E.S.; Carvalho, Elita F.U., E-mail: rcbpestana@gmail.com, E-mail: jesarkis@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Abreu Junior, Cassio H. [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil)

    2013-07-01

    Environmental swipe sampling for safeguards purposes is a powerful tool to detect undeclared materials and activities, and has been used by the International Atomic Energy Agency since 1997. This work describes the utilization of the inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for determining uranium isotopic ratios in a real-life swipe samples collected in a conversion plant at IPEN/CNEN, Brazil. Uncertainties were estimated by following the International Organization for Standardization - Guide to the Expression of Uncertainties in Measurement (ISO GUM), with a confidence level of 95%. The major uncertainties percentage for n({sup 235}U)/n({sup 238}U) ratio for ICP-MS was 3% and for LA-ICP-MS was 30% The values of uranium isotopic ratios obtained for each technique demonstrate the viability of these analytical techniques as an alternative tool for uranium analysis in swipe samples for safeguards purposes. (author)

  12. The use of ICP-MS and LA-ICP-MS techniques for uranium analysis in real-life swipe samples for safeguards purposes

    International Nuclear Information System (INIS)

    Pestana, Rafael C.B.; Sarkis, Jorge E.S.; Carvalho, Elita F.U.; Abreu Junior, Cassio H.

    2013-01-01

    Environmental swipe sampling for safeguards purposes is a powerful tool to detect undeclared materials and activities, and has been used by the International Atomic Energy Agency since 1997. This work describes the utilization of the inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for determining uranium isotopic ratios in a real-life swipe samples collected in a conversion plant at IPEN/CNEN, Brazil. Uncertainties were estimated by following the International Organization for Standardization - Guide to the Expression of Uncertainties in Measurement (ISO GUM), with a confidence level of 95%. The major uncertainties percentage for n( 235 U)/n( 238 U) ratio for ICP-MS was 3% and for LA-ICP-MS was 30% The values of uranium isotopic ratios obtained for each technique demonstrate the viability of these analytical techniques as an alternative tool for uranium analysis in swipe samples for safeguards purposes. (author)

  13. Sampling free energy surfaces as slices by combining umbrella sampling and metadynamics.

    Science.gov (United States)

    Awasthi, Shalini; Kapil, Venkat; Nair, Nisanth N

    2016-06-15

    Metadynamics (MTD) is a very powerful technique to sample high-dimensional free energy landscapes, and due to its self-guiding property, the method has been successful in studying complex reactions and conformational changes. MTD sampling is based on filling the free energy basins by biasing potentials and thus for cases with flat, broad, and unbound free energy wells, the computational time to sample them becomes very large. To alleviate this problem, we combine the standard Umbrella Sampling (US) technique with MTD to sample orthogonal collective variables (CVs) in a simultaneous way. Within this scheme, we construct the equilibrium distribution of CVs from biased distributions obtained from independent MTD simulations with umbrella potentials. Reweighting is carried out by a procedure that combines US reweighting and Tiwary-Parrinello MTD reweighting within the Weighted Histogram Analysis Method (WHAM). The approach is ideal for a controlled sampling of a CV in a MTD simulation, making it computationally efficient in sampling flat, broad, and unbound free energy surfaces. This technique also allows for a distributed sampling of a high-dimensional free energy surface, further increasing the computational efficiency in sampling. We demonstrate the application of this technique in sampling high-dimensional surface for various chemical reactions using ab initio and QM/MM hybrid molecular dynamics simulations. Further, to carry out MTD bias reweighting for computing forward reaction barriers in ab initio or QM/MM simulations, we propose a computationally affordable approach that does not require recrossing trajectories. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. Analytical dual-energy microtomography: A new method for obtaining three-dimensional mineral phase images and its application to Hayabusa samples

    Science.gov (United States)

    Tsuchiyama, A.; Nakano, T.; Uesugi, K.; Uesugi, M.; Takeuchi, A.; Suzuki, Y.; Noguchi, R.; Matsumoto, T.; Matsuno, J.; Nagano, T.; Imai, Y.; Nakamura, T.; Ogami, T.; Noguchi, T.; Abe, M.; Yada, T.; Fujimura, A.

    2013-09-01

    We developed a novel technique called "analytical dual-energy microtomography" that uses the linear attenuation coefficients (LACs) of minerals at two different X-ray energies to nondestructively obtain three-dimensional (3D) images of mineral distribution in materials such as rock specimens. The two energies are above and below the absorption edge energy of an abundant element, which we call the "index element". The chemical compositions of minerals forming solid solution series can also be measured. The optimal size of a sample is of the order of the inverse of the LAC values at the X-ray energies used. We used synchrotron-based microtomography with an effective spatial resolution of >200 nm to apply this method to small particles (30-180 μm) collected from the surface of asteroid 25143 Itokawa by the Hayabusa mission of the Japan Aerospace Exploration Agency (JAXA). A 3D distribution of the minerals was successively obtained by imaging the samples at X-ray energies of 7 and 8 keV, using Fe as the index element (the K-absorption edge of Fe is 7.11 keV). The optimal sample size in this case is of the order of 50 μm. The chemical compositions of the minerals, including the Fe/Mg ratios of ferromagnesian minerals and the Na/Ca ratios of plagioclase, were measured. This new method is potentially applicable to other small samples such as cosmic dust, lunar regolith, cometary dust (recovered by the Stardust mission of the National Aeronautics and Space Administration [NASA]), and samples from extraterrestrial bodies (those from future sample return missions such as the JAXA Hayabusa2 mission and the NASA OSIRIS-REx mission), although limitations exist for unequilibrated samples. Further, this technique is generally suited for studying materials in multicomponent systems with multiple phases across several research fields.

  15. From nestling calls to fledgling silence: adaptive timing of change in response to aerial alarm calls.

    Science.gov (United States)

    Magrath, Robert D; Platzen, Dirk; Kondo, Junko

    2006-09-22

    Young birds and mammals are extremely vulnerable to predators and so should benefit from responding to parental alarm calls warning of danger. However, young often respond differently from adults. This difference may reflect: (i) an imperfect stage in the gradual development of adult behaviour or (ii) an adaptation to different vulnerability. Altricial birds provide an excellent model to test for adaptive changes with age in response to alarm calls, because fledglings are vulnerable to a different range of predators than nestlings. For example, a flying hawk is irrelevant to a nestling in a enclosed nest, but is dangerous to that individual once it has left the nest, so we predict that young develop a response to aerial alarm calls to coincide with fledging. Supporting our prediction, recently fledged white-browed scrubwrens, Sericornis frontalis, fell silent immediately after playback of their parents' aerial alarm call, whereas nestlings continued to calling despite hearing the playback. Young scrubwrens are therefore exquisitely adapted to the changing risks faced during development.

  16. Staffing to Maximize Profit for Call Centers with Impatient and Repeat-Calling Customers

    Directory of Open Access Journals (Sweden)

    Jun Gong

    2015-01-01

    Full Text Available Motivated by call center practice, we study the optimal staffing of many-server queues with impatient and repeat-calling customers. A call center is modeled as an M/M/s+M queue, which is developed to a behavioral queuing model in which customers come and go based on their satisfaction with waiting time. We explicitly take into account customer repeat behavior, which implies that satisfied customers might return and have an impact on the arrival rate. Optimality is defined as the number of agents that maximize revenues net of staffing costs, and we account for the characteristic that revenues are a direct function of staffing. Finally, we use numerical experiments to make certain comparisons with traditional models that do not consider customer repeat behavior. Furthermore, we indicate how managers might allocate staffing optimally with various customer behavior mechanisms.

  17. Effect of postmortem sampling technique on the clinical significance of autopsy blood cultures.

    Science.gov (United States)

    Hove, M; Pencil, S D

    1998-02-01

    Our objective was to investigate the value of postmortem autopsy blood cultures performed with an iodine-subclavian technique relative to the classical method of atrial heat searing and antemortem blood cultures. The study consisted of a prospective autopsy series with each case serving as its own control relative to subsequent testing, and a retrospective survey of patients coming to autopsy who had both autopsy blood cultures and premortem blood cultures. A busy academic autopsy service (600 cases per year) at University of Texas Medical Branch Hospitals, Galveston, Texas, served as the setting for this work. The incidence of non-clinically relevant (false-positive) culture results were compared using different methods for collecting blood samples in a prospective series of 38 adult autopsy specimens. One hundred eleven adult autopsy specimens in which both postmortem and antemortem blood cultures were obtained were studied retrospectively. For both studies, positive culture results were scored as either clinically relevant or false positives based on analysis of the autopsy findings and the clinical summary. The rate of false-positive culture results obtained by an iodine-subclavian technique from blood drawn soon after death were statistically significantly lower (13%) than using the classical method of obtaining blood through the atrium after heat searing at the time of the autopsy (34%) in the same set of autopsy subjects. When autopsy results were compared with subjects' antemortem blood culture results, there was no significant difference in the rate of non-clinically relevant culture results in a paired retrospective series of antemortem blood cultures and postmortem blood cultures using the iodine-subclavian postmortem method (11.7% v 13.5%). The results indicate that autopsy blood cultures obtained using the iodine-subclavian technique have reliability equivalent to that of antemortem blood cultures.

  18. Advanced analytical techniques

    International Nuclear Information System (INIS)

    Mrochek, J.E.; Shumate, S.E.; Genung, R.K.; Bahner, C.T.; Lee, N.E.; Dinsmore, S.R.

    1976-01-01

    The development of several new analytical techniques for use in clinical diagnosis and biomedical research is reported. These include: high-resolution liquid chromatographic systems for the early detection of pathological molecular constituents in physiologic body fluids; gradient elution chromatography for the analysis of protein-bound carbohydrates in blood serum samples, with emphasis on changes in sera from breast cancer patients; electrophoretic separation techniques coupled with staining of specific proteins in cellular isoenzymes for the monitoring of genetic mutations and abnormal molecular constituents in blood samples; and the development of a centrifugal elution chromatographic technique for the assay of specific proteins and immunoglobulins in human blood serum samples

  19. Rural water tanks with HFB technique: technical guide

    CSIR Research Space (South Africa)

    Solsona, F

    1991-03-01

    Full Text Available This technical guide describes a very simple technique for water tank construction called H-F-B (heart filled blocks). The technique makes use of a simple mould (which can be made even in rural areas) for the manufacture of concrete building blocks...

  20. Attitudes of Jordanian Undergraduate Students towards Using Computer Assisted Language Learning (CALL

    Directory of Open Access Journals (Sweden)

    Farah Jamal Abed Alrazeq Saeed

    2018-01-01

    Full Text Available The study aimed at investigating the attitudes of Jordanian undergraduate students towards using computer assisted -language learning (CALL and its effectiveness in the process of learning the English language.  In order to fulfill the study’s objective, the researchers used a questionnaire to collect data, followed-up with semi-structured interviews to investigate the students’ beliefs towards CALL. Twenty- one of Jordanian BA students majoring in English language and literature were selected according to simple random sampling. The results revealed positive attitudes towards CALL in facilitating the process of writing assignments, gaining information; making learning enjoyable; improving their creativity, productivity, academic achievement, critical thinking skills, and enhancing their knowledge about vocabulary grammar, and culture. Furthermore, they believed that computers can motivate them to learn English language and help them to communicate and interact with their teachers and colleagues. The researchers recommended conducting a research on the same topic, taking into consideration the variables of age, gender, experience in using computers, and computer skills.

  1. Advanced sampling techniques for hand-held FT-IR instrumentation

    Science.gov (United States)

    Arnó, Josep; Frunzi, Michael; Weber, Chris; Levy, Dustin

    2013-05-01

    FT-IR spectroscopy is the technology of choice to identify solid and liquid phase unknown samples. The challenging ConOps in emergency response and military field applications require a significant redesign of the stationary FT-IR bench-top instruments typically used in laboratories. Specifically, field portable units require high levels of resistance against mechanical shock and chemical attack, ease of use in restrictive gear, extreme reliability, quick and easy interpretation of results, and reduced size. In the last 20 years, FT-IR instruments have been re-engineered to fit in small suitcases for field portable use and recently further miniaturized for handheld operation. This article introduces the HazMatID™ Elite, a FT-IR instrument designed to balance the portability advantages of a handheld device with the performance challenges associated with miniaturization. In this paper, special focus will be given to the HazMatID Elite's sampling interfaces optimized to collect and interrogate different types of samples: accumulated material using the on-board ATR press, dispersed powders using the ClearSampler™ tool, and the touch-to-sample sensor for direct liquid sampling. The application of the novel sample swipe accessory (ClearSampler) to collect material from surfaces will be discussed in some detail. The accessory was tested and evaluated for the detection of explosive residues before and after detonation. Experimental results derived from these investigations will be described in an effort to outline the advantages of this technology over existing sampling methods.

  2. A rapid method of radium-226 analysis in water samples using an alpha spectroscopic technique

    International Nuclear Information System (INIS)

    Lim, T.P.

    1981-01-01

    A fast, reliable and accurate method for radium-226 determination in environmental water samples has been devised, using an alpha spectroscopic technique. The correlation between barium-133 and radium-226 in the barium-radium sulphate precipitation mechanism was studied and in the limited experimental recovery range, the coefficient of correlation was r = 0.986. A self-absorption study for various barium carrier concentrations was also undertaken to obtain the least broadening of alpha energy line widths. An optimum value of 0.3 mg barium carrier was obtained for chemical recovery in the range of 85 percent. (auth)

  3. An extension of command shaping methods for controlling residual vibration using frequency sampling

    Science.gov (United States)

    Singer, Neil C.; Seering, Warren P.

    1992-01-01

    The authors present an extension to the impulse shaping technique for commanding machines to move with reduced residual vibration. The extension, called frequency sampling, is a method for generating constraints that are used to obtain shaping sequences which minimize residual vibration in systems such as robots whose resonant frequencies change during motion. The authors present a review of impulse shaping methods, a development of the proposed extension, and a comparison of results of tests conducted on a simple model of the space shuttle robot arm. Frequency shaping provides a method for minimizing the impulse sequence duration required to give the desired insensitivity.

  4. Avoiding escalation from play to aggression in adult male rats: The role of ultrasonic calls.

    Science.gov (United States)

    Burke, Candace J; Kisko, Theresa M; Pellis, Sergio M; Euston, David R

    2017-11-01

    Play fighting is most commonly associated with juvenile animals, but in some species, including rats, it can continue into adulthood. Post-pubertal engagement in play fighting is often rougher and has an increased chance of escalation to aggression, making the use of play signals to regulate the encounter more critical. During play, both juvenile and adult rats emit many 50-kHz calls and some of these may function as play facilitating signals. In the present study, unfamiliar adult male rats were introduced in a neutral enclosure and their social interactions were recorded. While all pairs escalated their playful encounters to become rougher, only the pairs in which one member was devocalized escalated to serious biting. A Monte Carlo shuffling technique was used for the analysis of the correlations between the overt playful and aggressive actions performed and the types and frequencies of various 50-kHz calls that were emitted. The analysis revealed that lower frequency (20-30kHz) calls with a flat component maybe particularly critical for de-escalating encounters and so allowing play to continue. Moreover, coordinating calls reciprocally, with either the same call mimicked in close, temporal association or with complementary calls emitted by participants as they engage in complementary actions (e.g., attacking the nape, being attacked on the nape), appeared to be ways with which calls could be potentially used to avoid escalation to aggression and so sustain playful interactions. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. [Comparison of the determination of cyclosporin-A in blood samples collected on filter paper and by the ordinary technique].

    Science.gov (United States)

    Azevedo, L S; Manrique, R; Sabbaga, E

    1995-01-01

    Monitoring cyclosporin-A (CsA) blood levels is of utmost importance for the rational use of this drug. Although many centers perform transplants, in Brazil there are few laboratories able to measure CsA blood levels. Therefore making blood samples reach the laboratory emerged as a problem. Collection of blood on filter paper has been a technique used for a long time in special cases. PURPOSE--To confirm the usefulness of measuring CsA blood levels in blood samples collected on filter paper and in the usual way. METHOD--We studied twenty renal cadaver kidney recipients who were receiving CsA, azathioprine and prednisone. Ninety five blood samples were collected and divided into two aliquots. One of them was sent routinely to one laboratory to perform whole blood CsA measurements. From the other aliquot, 20 microliters were pipetted on filter paper. When dried they were mailed to the other laboratory, where, after elution, CsA was measured. In both cases radioimmunoassay with polyclonal antibody was used. RESULTS--Linear correlation between both measurements revealed r = 0.81 with no statistical difference. CONCLUSION--The technique showed to be useful in clinical practice. In countries with continental size, as Brazil, it may be very helpful.

  6. Survey research with a random digit dial national mobile phone sample in Ghana: Methods and sample quality

    Science.gov (United States)

    Sefa, Eunice; Adimazoya, Edward Akolgo; Yartey, Emmanuel; Lenzi, Rachel; Tarpo, Cindy; Heward-Mills, Nii Lante; Lew, Katherine; Ampeh, Yvonne

    2018-01-01

    Introduction Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample. Materials and methods The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census. Results The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample. Conclusions The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in

  7. Survey research with a random digit dial national mobile phone sample in Ghana: Methods and sample quality.

    Science.gov (United States)

    L'Engle, Kelly; Sefa, Eunice; Adimazoya, Edward Akolgo; Yartey, Emmanuel; Lenzi, Rachel; Tarpo, Cindy; Heward-Mills, Nii Lante; Lew, Katherine; Ampeh, Yvonne

    2018-01-01

    Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample. The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census. The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample. The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in comparison to household surveys. Random digit dialing of mobile

  8. Survey research with a random digit dial national mobile phone sample in Ghana: Methods and sample quality.

    Directory of Open Access Journals (Sweden)

    Kelly L'Engle

    Full Text Available Generating a nationally representative sample in low and middle income countries typically requires resource-intensive household level sampling with door-to-door data collection. High mobile phone penetration rates in developing countries provide new opportunities for alternative sampling and data collection methods, but there is limited information about response rates and sample biases in coverage and nonresponse using these methods. We utilized data from an interactive voice response, random-digit dial, national mobile phone survey in Ghana to calculate standardized response rates and assess representativeness of the obtained sample.The survey methodology was piloted in two rounds of data collection. The final survey included 18 demographic, media exposure, and health behavior questions. Call outcomes and response rates were calculated according to the American Association of Public Opinion Research guidelines. Sample characteristics, productivity, and costs per interview were calculated. Representativeness was assessed by comparing data to the Ghana Demographic and Health Survey and the National Population and Housing Census.The survey was fielded during a 27-day period in February-March 2017. There were 9,469 completed interviews and 3,547 partial interviews. Response, cooperation, refusal, and contact rates were 31%, 81%, 7%, and 39% respectively. Twenty-three calls were dialed to produce an eligible contact: nonresponse was substantial due to the automated calling system and dialing of many unassigned or non-working numbers. Younger, urban, better educated, and male respondents were overrepresented in the sample.The innovative mobile phone data collection methodology yielded a large sample in a relatively short period. Response rates were comparable to other surveys, although substantial coverage bias resulted from fewer women, rural, and older residents completing the mobile phone survey in comparison to household surveys. Random digit

  9. Peafowl antipredator calls encode information about signalers.

    Science.gov (United States)

    Yorzinski, Jessica L

    2014-02-01

    Animals emit vocalizations that convey information about external events. Many of these vocalizations, including those emitted in response to predators, also encode information about the individual that produced the call. The relationship between acoustic features of antipredator calls and information relating to signalers (including sex, identity, body size, and social rank) were examined in peafowl (Pavo cristatus). The "bu-girk" antipredator calls of male and female peafowl were recorded and 20 acoustic parameters were automatically extracted from each call. Both the bu and girk elements of the antipredator call were individually distinctive and calls were classified to the correct signaler with over 90% and 70% accuracy in females and males, respectively. Females produced calls with a higher fundamental frequency (F0) than males. In both females and males, body size was negatively correlated with F0. In addition, peahen rank was related to the duration, end mean frequency, and start harmonicity of the bu element. Peafowl antipredator calls contain detailed information about the signaler and can potentially be used by receivers to respond to dangerous situations.

  10. Equipment and techniques for remote sampling of stored radioactive waste

    International Nuclear Information System (INIS)

    Nance, T.A.

    1996-01-01

    Several tools have been developed at the Savannah River Site (SRS) to remotely sample stored radioactive waste. These sampling tools have been developed to determine the chemical characteristics of the waste prior to processing. The processing of waste material varies according to the chemical characteristics of the waste, which change due to additions, settling, mixing, and chemical reactions during storage. Once the waste has been sampled to identify its characteristics, the chemical composition of the waste can then be altered if needed to prepare for processing. Various types of waste material in several types of containment must be sampled at SRS. Stored waste materials consist of liquids, floating organics, sludge, salt and solids. Waste is stored in four basic types of tanks with different means of access and interior obstructions. The waste tanks can only be accessed by small openings: access ports, risers and downcomers. Requirements for sampling depend on the type of tank being accessed, the waste within the tank, and the particular location in the tank desired for taking the sample. Sampling devices have been developed to sample all of the waste material forms found in the SRS tank farms. The fluid type samplers are capable of sampling surface liquid, subsurface liquid at varying depth, surface sludge, subsurface sludge, and floating organics. The solid type samplers are capable of sampling salt, sampling a solid layer on the bottom of the tank, and capturing a small solid mass on the tank bottom. The sampling devices are all designed to access the tanks through small access ports. The samplers are reusable and are designed to allow quick transfer of the samples to shielded packaging for transport, reducing the amount of radiation exposure to sampling personnel. The samplers weigh less than 100 lb. and are designed in sections to allow easy disassembly for storage and transport by personnel. (Abstract Truncated)

  11. BUFO PARDALIS (ANURA: BUFONIDAE): MATING CALL AND ...

    African Journals Online (AJOL)

    the calls of one of these species, Bufo pardalis. Hewitt, were not analysed by Tandy & Keith. (1972). Furthennore there is some confusion in the literature regarding the mating call of this species. For these reasons this mating call is here clarified. The mating call of B. pardaiis was first described by Ranger (in Hewitt 1935) as ...

  12. Evaluating organochlorine pesticide residues in the aquatic environment of the Lake Naivasha River basin using passive sampling techniques.

    Science.gov (United States)

    Abbasi, Yasser; Mannaerts, Chris M

    2018-05-18

    Passive sampling techniques can improve the discovery of low concentrations by continuous collecting the contaminants, which usually go undetected with classic and once-off time-point grab sampling. The aim of this study was to evaluate organochlorine pesticide (OCP) residues in the aquatic environment of the Lake Naivasha river basin (Kenya) using passive sampling techniques. Silicone rubber sheet and Speedisk samplers were used to detect residues of α-HCH, β-HCH, γ-HCH, δ-HCH, heptachlor, aldrin, heptachlor epoxide, pp-DDE, endrin, dieldrin, α-endosulfan, β-endosulfan, pp-DDD, endrin aldehyde, pp-DDT, endosulfan sulfate, and methoxychlor in the Malewa River and Lake Naivasha. After solvent extraction from the sampling media, the residues were analyzed using gas chromatography electron capture detection (GC-ECD) for the OCPs and gas chromatography-mass spectrometry (GC-MS) for the PCB reference compounds. Measuring the OCP residues using the silicone rubber samplers revealed the highest concentration of residues (∑OCPs of 81 (± 18.9 SD) μg/L) to be at the Lake site, being the ultimate accumulation environment for surficial hydrological, chemical, and sediment transport through the river basin. The total OCP residue sums changed to 71.5 (± 11.3 SD) μg/L for the Middle Malewa and 59 (± 12.5 SD) μg/L for the Upper Malewa River sampling sites. The concentration sums of OCPs detected using the Speedisk samplers at the Upper Malewa, Middle Malewa, and the Lake Naivasha sites were 28.2 (± 4.2 SD), 31.3 (± 1.8 SD), and 34.2 (± 6.4 SD) μg/L, respectively. An evaluation of the different pesticide compound variations identified at the three sites revealed that endosulfan sulfate, α-HCH, methoxychlor, and endrin aldehyde residues were still found at all sampling sites. However, the statistical analysis of one-way ANOVA for testing the differences of ∑OCPs between the sampling sites for both the silicone rubber sheet and Speedisk samplers

  13. CoVaCS: a consensus variant calling system.

    Science.gov (United States)

    Chiara, Matteo; Gioiosa, Silvia; Chillemi, Giovanni; D'Antonio, Mattia; Flati, Tiziano; Picardi, Ernesto; Zambelli, Federico; Horner, David Stephen; Pesole, Graziano; Castrignanò, Tiziana

    2018-02-05

    The advent and ongoing development of next generation sequencing technologies (NGS) has led to a rapid increase in the rate of human genome re-sequencing data, paving the way for personalized genomics and precision medicine. The body of genome resequencing data is progressively increasing underlining the need for accurate and time-effective bioinformatics systems for genotyping - a crucial prerequisite for identification of candidate causal mutations in diagnostic screens. Here we present CoVaCS, a fully automated, highly accurate system with a web based graphical interface for genotyping and variant annotation. Extensive tests on a gold standard benchmark data-set -the NA12878 Illumina platinum genome- confirm that call-sets based on our consensus strategy are completely in line with those attained by similar command line based approaches, and far more accurate than call-sets from any individual tool. Importantly our system exhibits better sensitivity and higher specificity than equivalent commercial software. CoVaCS offers optimized pipelines integrating state of the art tools for variant calling and annotation for whole genome sequencing (WGS), whole-exome sequencing (WES) and target-gene sequencing (TGS) data. The system is currently hosted at Cineca, and offers the speed of a HPC computing facility, a crucial consideration when large numbers of samples must be analysed. Importantly, all the analyses are performed automatically allowing high reproducibility of the results. As such, we believe that CoVaCS can be a valuable tool for the analysis of human genome resequencing studies. CoVaCS is available at: https://bioinformatics.cineca.it/covacs .

  14. Impact of mobility on call block, call drops and optimal cell size in small cell networks

    OpenAIRE

    Ramanath , Sreenath; Voleti , Veeraruna Kavitha; Altman , Eitan

    2011-01-01

    We consider small cell networks and study the impact of user mobility. Assuming Poisson call arrivals at random positions with random velocities, we discuss the characterization of handovers at the boundaries. We derive explicit expressions for call block and call drop probabilities using tools from spatial queuing theory. We also derive expressions for the average virtual server held up time. These expressions are used to derive optimal cell sizes for various profile of velocities in small c...

  15. Three Proposed Compendia for Genesis Solar Wind Samples: Science Results, Collector Materials Characterization and Cleaning Techniques

    Science.gov (United States)

    Allton, J. H.; Calaway, M. J.; Nyquist, L. E.; Jurewicz, A. J. G.; Burnett, D. S.

    2018-01-01

    Final Paper and not the abstract is attached. Introduction: Planetary material and cosmochemistry research using Genesis solar wind samples (including the development and implementation of cleaning and analytical techniques) has matured sufficiently that compilations on several topics, if made publically accessible, would be beneficial for researchers and reviewers. We propose here three compendia based on content, organization and source of documents (e.g. published peer-reviewed, published, internal memos, archives). For planning purposes, suggestions are solicited from potential users of Genesis solar wind samples for the type of science content and/or organizational style that would be most useful to them. These compendia are proposed as living documents, periodically updated. Similar to the existing compendia described below, the curation compendia are like library or archival finding aids, they are guides to published or archival documents and should not be cited as primary sources.

  16. Innovative hybrid pile oscillator technique in the Minerve reactor: open loop vs. closed loop

    Directory of Open Access Journals (Sweden)

    Geslot Benoit

    2018-01-01

    Full Text Available Pile oscillator techniques are powerful methods to measure small reactivity worth of isotopes of interest for nuclear data improvement. This kind of experiments has long been implemented in the Mineve experimental reactor, operated by CEA Cadarache. A hybrid technique, mixing reactivity worth estimation and measurement of small changes around test samples is presented here. It was made possible after the development of high sensitivity miniature fission chambers introduced next to the irradiation channel. A test campaign, called MAESTRO-SL, took place in 2015. Its objective was to assess the feasibility of the hybrid method and investigate the possibility to separate mixed neutron effects, such as fission/capture or scattering/capture. Experimental results are presented and discussed in this paper, which focus on comparing two measurements setups, one using a power control system (closed loop and another one where the power is free to drift (open loop. First, it is demonstrated that open loop is equivalent to closed loop. Uncertainty management and methods reproducibility are discussed. Second, results show that measuring the flux depression around oscillated samples provides valuable information regarding partial neutron cross sections. The technique is found to be very sensitive to the capture cross section at the expense of scattering, making it very useful to measure small capture effects of highly scattering samples.

  17. Comparison and evaluation of two exome capture kits and sequencing platforms for variant calling.

    Science.gov (United States)

    Zhang, Guoqiang; Wang, Jianfeng; Yang, Jin; Li, Wenjie; Deng, Yutian; Li, Jing; Huang, Jun; Hu, Songnian; Zhang, Bing

    2015-08-05

    To promote the clinical application of next-generation sequencing, it is important to obtain accurate and consistent variants of target genomic regions at low cost. Ion Proton, the latest updated semiconductor-based sequencing instrument from Life Technologies, is designed to provide investigators with an inexpensive platform for human whole exome sequencing that achieves a rapid turnaround time. However, few studies have comprehensively compared and evaluated the accuracy of variant calling between Ion Proton and Illumina sequencing platforms such as HiSeq 2000, which is the most popular sequencing platform for the human genome. The Ion Proton sequencer combined with the Ion TargetSeq Exome Enrichment Kit together make up TargetSeq-Proton, whereas SureSelect-Hiseq is based on the Agilent SureSelect Human All Exon v4 Kit and the HiSeq 2000 sequencer. Here, we sequenced exonic DNA from four human blood samples using both TargetSeq-Proton and SureSelect-HiSeq. We then called variants in the exonic regions that overlapped between the two exome capture kits (33.6 Mb). The rates of shared variant loci called by two sequencing platforms were from 68.0 to 75.3% in four samples, whereas the concordance of co-detected variant loci reached 99%. Sanger sequencing validation revealed that the validated rate of concordant single nucleotide polymorphisms (SNPs) (91.5%) was higher than the SNPs specific to TargetSeq-Proton (60.0%) or specific to SureSelect-HiSeq (88.3%). With regard to 1-bp small insertions and deletions (InDels), the Sanger sequencing validated rates of concordant variants (100.0%) and SureSelect-HiSeq-specific (89.6%) were higher than those of TargetSeq-Proton-specific (15.8%). In the sequencing of exonic regions, a combination of using of two sequencing strategies (SureSelect-HiSeq and TargetSeq-Proton) increased the variant calling specificity for concordant variant loci and the sensitivity for variant loci called by any one platform. However, for the

  18. Teknik Sampling Snowball dalam Penelitian Lapangan

    OpenAIRE

    Nina Nurdiani

    2014-01-01

    Field research can be associated with both qualitative and quantitative research methods, depending on the problems faced and the goals to be achieved. The success of data collection in the field research depends on the determination of the appropriate sampling technique, to obtain accurate data, and reliably. In studies that have problems related to specific issues, requiring a non-probability sampling techniques one of which is the snowball sampling technique. This technique is useful for f...

  19. Green approaches in sample preparation of bioanalytical samples prior to chromatographic analysis.

    Science.gov (United States)

    Filippou, Olga; Bitas, Dimitrios; Samanidou, Victoria

    2017-02-01

    Sample preparation is considered to be the most challenging step of the analytical procedure, since it has an effect on the whole analytical methodology, therefore it contributes significantly to the greenness or lack of it of the entire process. The elimination of the sample treatment steps, pursuing at the same time the reduction of the amount of the sample, strong reductions in consumption of hazardous reagents and energy also maximizing safety for operators and environment, the avoidance of the use of big amount of organic solvents, form the basis for greening sample preparation and analytical methods. In the last decade, the development and utilization of greener and sustainable microextraction techniques is an alternative to classical sample preparation procedures. In this review, the main green microextraction techniques (solid phase microextraction, stir bar sorptive extraction, hollow-fiber liquid phase microextraction, dispersive liquid - liquid microextraction, etc.) will be presented, with special attention to bioanalytical applications of these environment-friendly sample preparation techniques which comply with the green analytical chemistry principles. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Explaining the so-called 'price premium' in oil markets

    International Nuclear Information System (INIS)

    Merino, A.; Ortiz, A.

    2005-01-01

    This paper explores the information content of several variables on the so-called ''oil price premium over fundamentals''. We define this premium as the difference between the market oil price and the estimated price consistent with the OECD's relative industry stock level. By using Granger causality tests and extended regressions we test the systematic ability of a broad set of variables to explain the premium. We find that speculation in the oil market - measured by non-commercial long positions - can improve the traditional model, reducing the premium significantly during some parts of the sample. (author)

  1. External GSM phone calls now made simpler

    CERN Multimedia

    2007-01-01

    On 2 July, the IT/CS Telecom Service introduced a new service making external calls from CERN GSM phones easier. A specific prefix is no longer needed for calls outside CERN. External calls from CERN GSM phones are to be simplified. It is no longer necessary to use a special prefix to call an external number from the CERN GSM network.The Telecom Section of the IT/CS Group is introducing a new system that will make life easier for GSM users. It is no longer necessary to use a special prefix (333) to call an external number from the CERN GSM network. Simply dial the number directly like any other Swiss GSM customer. CERN currently has its own private GSM network with the Swiss mobile operator, Sunrise, covering the whole of Switzerland. This network was initially intended exclusively for calls between CERN numbers (replacing the old beeper system). A special system was later introduced for external calls, allowing them to pass thr...

  2. Simultaneous determination of major to ultratrace elements in geological samples by fusion-dissolution and inductively coupled plasma mass spectrometry techniques

    International Nuclear Information System (INIS)

    Madinabeitia, S. Garcia de; Lorda, M.E. Sanchez; Ibarguchi, J.I. Gil

    2008-01-01

    A method has been developed for the simultaneous quantification of major to ultratrace elements in geological samples using quadrupole ICP-MS techniques. The sample preparation involves fusion with LiBO 2 and dilution in HNO 3 -HF which allows complete decomposition of refractory minerals and quantification of the elements of interest. The effects of high Total Dissolved Solids (TDS) and Li in the solution are minimized using a matrix-tolerant interface and conditioning the instrument with LiBO 2 solution. The signal drift is moreover controlled using conventional internal standards and specific Drift Correction Standards (DCS). A key issue of the technique is the external calibration using selected Certified Reference Materials (CRM). Depending on the sample type and analytes of interest three optimized programmable modes are used sequentially: Standard, Collision Cell (CCT) and Kinetic Energy Discrimination (KED) mode. The method allows to quantify more than 40 elements in concentrations from tens-of-percent to <0.1 ppm levels during a single experiment. The method has been validated through the analysis of different CRMs with recovery factors of ca. 100% and typical 2σ errors of <10%

  3. Simultaneous determination of major to ultratrace elements in geological samples by fusion-dissolution and inductively coupled plasma mass spectrometry techniques

    Energy Technology Data Exchange (ETDEWEB)

    Madinabeitia, S. Garcia de [Servicio de Geocronologia y Geoquimica Isotopica, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco/EHU, Sarriena s/n, 48940 Leioa (Spain); Lorda, M.E. Sanchez [Servicio de Geocronologia y Geoquimica Isotopica, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco/EHU, Sarriena s/n, 48940 Leioa (Spain); Departamento de Mineralogia-Petrologia, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco/EHU, Sarriena s/n, 48940 Leioa (Spain); Ibarguchi, J.I. Gil [Servicio de Geocronologia y Geoquimica Isotopica, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco/EHU, Sarriena s/n, 48940 Leioa (Spain)], E-mail: josei.gil@ehu.es

    2008-09-12

    A method has been developed for the simultaneous quantification of major to ultratrace elements in geological samples using quadrupole ICP-MS techniques. The sample preparation involves fusion with LiBO{sub 2} and dilution in HNO{sub 3}-HF which allows complete decomposition of refractory minerals and quantification of the elements of interest. The effects of high Total Dissolved Solids (TDS) and Li in the solution are minimized using a matrix-tolerant interface and conditioning the instrument with LiBO{sub 2} solution. The signal drift is moreover controlled using conventional internal standards and specific Drift Correction Standards (DCS). A key issue of the technique is the external calibration using selected Certified Reference Materials (CRM). Depending on the sample type and analytes of interest three optimized programmable modes are used sequentially: Standard, Collision Cell (CCT) and Kinetic Energy Discrimination (KED) mode. The method allows to quantify more than 40 elements in concentrations from tens-of-percent to <0.1 ppm levels during a single experiment. The method has been validated through the analysis of different CRMs with recovery factors of ca. 100% and typical 2{sigma} errors of <10%.

  4. Comparison of laser fluorimetry, high resolution gamma-ray spectrometry and neutron activation analysis techniques for determination of uranium content in soil samples

    International Nuclear Information System (INIS)

    Ghods, A.; Asgharizadeh, F.; Salimi, B.; Abbasi, A.

    2004-01-01

    Much more concern is given nowadays for exposure of the world population to natural radiation especially to uranium since 57% of that exposure is due to radon-222, which is a member of uranium decay series. Most of the methods used for uranium determination is low concentration require either tedious separation and preconcentration or the accessibility to special instrumentation for detection of uranium at this low level. this study compares three techniques and methods for uranium analysis among different soil sample with variable uranium contents. Two of these techniques, neutron activation analysis and high resolution gamma-ray spectrometry , are non-destructive while the other, laser fluorimetry is done via chemical extraction of uranium. Analysis of standard materials is done also to control the quality and accuracy of the work. In spite of having quite variable ranges of detection limit, results obtained by high resolution gamma-ray spectrometry based on the assumption of having secular equilibrium between uranium and its daughters, which causes deviation whenever this condition was missed. For samples with reasonable uranium content, neutron activation analysis would be a rapid and reliable technique, while for low uranium content laser fluorimetry would be the most appropriate and accurate technique

  5. Study of gastric cancer samples using terahertz techniques

    Science.gov (United States)

    Wahaia, Faustino; Kasalynas, Irmantas; Seliuta, Dalius; Molis, Gediminas; Urbanowicz, Andrzej; Carvalho Silva, Catia D.; Carneiro, Fatima; Valusis, Gintaras; Granja, Pedro L.

    2014-08-01

    In the present work, samples of healthy and adenocarcinoma-affected human gastric tissue were analyzed using transmission time-domain THz spectroscopy (THz-TDS) and spectroscopic THz imaging at 201 and 590 GHz. The work shows that it is possible to distinguish between normal and cancerous regions in dried and paraffin-embedded samples. Plots of absorption coefficient α and refractive index n of normal and cancer affected tissues, as well as 2-D transmission THz images are presented and the conditions for discrimination between normal and affected tissues are discussed.

  6. Sharing programming resources between Bio* projects through remote procedure call and native call stack strategies.

    Science.gov (United States)

    Prins, Pjotr; Goto, Naohisa; Yates, Andrew; Gautier, Laurent; Willis, Scooter; Fields, Christopher; Katayama, Toshiaki

    2012-01-01

    Open-source software (OSS) encourages computer programmers to reuse software components written by others. In evolutionary bioinformatics, OSS comes in a broad range of programming languages, including C/C++, Perl, Python, Ruby, Java, and R. To avoid writing the same functionality multiple times for different languages, it is possible to share components by bridging computer languages and Bio* projects, such as BioPerl, Biopython, BioRuby, BioJava, and R/Bioconductor. In this chapter, we compare the two principal approaches for sharing software between different programming languages: either by remote procedure call (RPC) or by sharing a local call stack. RPC provides a language-independent protocol over a network interface; examples are RSOAP and Rserve. The local call stack provides a between-language mapping not over the network interface, but directly in computer memory; examples are R bindings, RPy, and languages sharing the Java Virtual Machine stack. This functionality provides strategies for sharing of software between Bio* projects, which can be exploited more often. Here, we present cross-language examples for sequence translation, and measure throughput of the different options. We compare calling into R through native R, RSOAP, Rserve, and RPy interfaces, with the performance of native BioPerl, Biopython, BioJava, and BioRuby implementations, and with call stack bindings to BioJava and the European Molecular Biology Open Software Suite. In general, call stack approaches outperform native Bio* implementations and these, in turn, outperform RPC-based approaches. To test and compare strategies, we provide a downloadable BioNode image with all examples, tools, and libraries included. The BioNode image can be run on VirtualBox-supported operating systems, including Windows, OSX, and Linux.

  7. Applying a low energy HPGe detector gamma ray spectrometric technique for the evaluation of Pu/Am ratio in biological samples.

    Science.gov (United States)

    Singh, I S; Mishra, Lokpati; Yadav, J R; Nadar, M Y; Rao, D D; Pradeepkumar, K S

    2015-10-01

    The estimation of Pu/(241)Am ratio in the biological samples is an important input for the assessment of internal dose received by the workers. The radiochemical separation of Pu isotopes and (241)Am in a sample followed by alpha spectrometry is a widely used technique for the determination of Pu/(241)Am ratio. However, this method is time consuming and many times quick estimation is required. In this work, Pu/(241)Am ratio in the biological sample was estimated with HPGe detector based measurements using gamma/X-rays emitted by these radionuclides. These results were compared with those obtained from alpha spectroscopy of sample after radiochemical analysis and found to be in good agreement. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Call Duration Characteristics based on Customers Location

    Directory of Open Access Journals (Sweden)

    Žvinys Karolis

    2014-05-01

    Full Text Available Nowadays a lot of different researches are performed based on call duration distributions (CDD analysis. However, the majority of studies are linked with social relationships between the people. Therefore the scarcity of information, how the call duration is associated with a user's location, is appreciable. The goal of this paper is to reveal the ties between user's voice call duration and the location of call. For this reason we analyzed more than 5 million calls from real mobile network, which were made over the base stations located in rural areas, roads, small towns, business and entertainment centers, residential districts. According to these site types CDD’s and characteristic features for call durations are given and discussed. Submitted analysis presents the users habits and behavior as a group (not an individual. The research showed that CDD’s of customers being them in different locations are not equal. It has been found that users at entertainment, business centers are tend to talk much shortly, than people being at home. Even more CDD can be distorted strongly, when machinery calls are evaluated. Hence to apply a common CDD for a whole network it is not recommended. The study also deals with specific parameters of call duration for distinguished user groups, the influence of network technology for call duration is considered.

  9. Sampling, storage and sample preparation procedures for X ray fluorescence analysis of environmental materials

    International Nuclear Information System (INIS)

    1997-06-01

    X ray fluorescence (XRF) method is one of the most commonly used nuclear analytical technique because of its multielement and non-destructive character, speed, economy and ease of operation. From the point of view of quality assurance practices, sampling and sample preparation procedures are the most crucial steps in all analytical techniques, (including X ray fluorescence) applied for the analysis of heterogeneous materials. This technical document covers recent modes of the X ray fluorescence method and recent developments in sample preparation techniques for the analysis of environmental materials. Refs, figs, tabs

  10. Sample preparation techniques of biological material for isotope analysis

    International Nuclear Information System (INIS)

    Axmann, H.; Sebastianelli, A.; Arrillaga, J.L.

    1990-01-01

    Sample preparation is an essential step in all isotope-aided experiments but often it is not given enough attention. The methods of sample preparation are very important to obtain reliable and precise analytical data and for further interpretation of results. The size of a sample required for chemical analysis is usually very small (10mg-1500mg). On the other hand the amount of harvested plant material from plots in a field experiment is often bulky (several kilograms) and the entire sample is too large for processing. In addition, while approaching maturity many crops show not only differences in physical consistency but also a non-uniformity in 15 N content among plant parts, requiring a plant fractionation or separation into parts (vegetative and reproductive) e.g. shoots and spikes, in case of small grain cereals, shoots and pods in case of grain legumes and tops and roots or beets (including crown) in case of sugar beet, etc. In any case the ultimate goal of these procedures is to obtain representative subsample harvested from greenhouse or field experiments for chemical analysis. Before harvesting an isotopic-aided experiment the method of sampling has to be selected. It should be based on the type of information required in relation to the objectives of the research and the availability of resources (staff, sample preparation equipment, analytical facilities, chemicals and supplies, etc.). 10 refs, 3 figs, 3 tabs

  11. A simple air sampling technique for monitoring nitrous oxide pollution

    Energy Technology Data Exchange (ETDEWEB)

    Austin, J C; Shaw, R; Moyes, D; Cleaton-Jones, P E

    1981-01-01

    A simple, inexpensive device for the continuous low-flow sampling of air was devised to permit monitoring of pollution by gaseous anaesthetics. The device consisted of a water-filled Perspex cylinder in which a double-walled flexible-film gas sample collection bag was suspended. Air samples could be aspirated into the collection bag at flow rates of as low as 1 ml min-1 by allowing the water to drain from the cylinder at a controlled rate. The maintenance of sample integrity with aspiration and storage of samples of nitrous oxide in air at concentrations of 1000, 100 and 30 p.p.m. v/v was examined using gas chromatography. The sample bags retained a mean 94% of the nitrous oxide in air samples containing nitrous oxide 25 p.p.m. over a 72-h storage period.

  12. Asteroseismic inversions in the Kepler era: application to the Kepler Legacy sample

    Directory of Open Access Journals (Sweden)

    Buldgen Gaël

    2017-01-01

    Full Text Available In the past few years, the CoRoT and Kepler missions have carried out what is now called the space photometry revolution. This revolution is still ongoing thanks to K2 and will be continued by the Tess and Plato2.0 missions. However, the photometry revolution must also be followed by progress in stellar modelling, in order to lead to more precise and accurate determinations of fundamental stellar parameters such as masses, radii and ages. In this context, the long-lasting problems related to mixing processes in stellar interior is the main obstacle to further improvements of stellar modelling. In this contribution, we will apply structural asteroseismic inversion techniques to targets from the Kepler Legacy sample and analyse how these can help us constrain the fundamental parameters and mixing processes in these stars. Our approach is based on previous studies using the SOLA inversion technique [1] to determine integrated quantities such as the mean density [2], the acoustic radius, and core conditions indicators [3], and has already been successfully applied to the 16Cyg binary system [4]. We will show how this technique can be applied to the Kepler Legacy sample and how new indicators can help us to further constrain the chemical composition profiles of stars as well as provide stringent constraints on stellar ages.

  13. Asteroseismic inversions in the Kepler era: application to the Kepler Legacy sample

    Science.gov (United States)

    Buldgen, Gaël; Reese, Daniel; Dupret, Marc-Antoine

    2017-10-01

    In the past few years, the CoRoT and Kepler missions have carried out what is now called the space photometry revolution. This revolution is still ongoing thanks to K2 and will be continued by the Tess and Plato2.0 missions. However, the photometry revolution must also be followed by progress in stellar modelling, in order to lead to more precise and accurate determinations of fundamental stellar parameters such as masses, radii and ages. In this context, the long-lasting problems related to mixing processes in stellar interior is the main obstacle to further improvements of stellar modelling. In this contribution, we will apply structural asteroseismic inversion techniques to targets from the Kepler Legacy sample and analyse how these can help us constrain the fundamental parameters and mixing processes in these stars. Our approach is based on previous studies using the SOLA inversion technique [1] to determine integrated quantities such as the mean density [2], the acoustic radius, and core conditions indicators [3], and has already been successfully applied to the 16Cyg binary system [4]. We will show how this technique can be applied to the Kepler Legacy sample and how new indicators can help us to further constrain the chemical composition profiles of stars as well as provide stringent constraints on stellar ages.

  14. On-call service of neurosurgeons in Germany: organization, use of communication services, and personal acceptance of modern technologies.

    Science.gov (United States)

    Brenke, Christopher; Lassel, Elke A; Terris, Darcey; Kurt, Aysel; Schmieder, Kirsten; Schoenberg, Stefan O; Weisser, Gerald

    2014-05-01

    A significant proportion of acute care neurosurgical patients present to hospital outside regular working hours. The objective of our study was to evaluate the structure of neurosurgical on-call services in Germany, the use of modern communication devices and teleradiology services, and the personal acceptance of modern technologies by neurosurgeons. A nationwide survey of all 141 neurosurgical departments in Germany was performed. The questionnaire consisted of two parts: one for neurosurgical departments and one for individual neurosurgeons. The questionnaire, available online and mailed in paper form, included 21 questions about on-call service structure; the availability and use of communication devices, teleradiology services, and other information services; and neurosurgeons' personal acceptance of modern technologies. The questionnaire return rate from departments was 63.1% (89/141), whereas 187 individual neurosurgeons responded. For 57.3% of departments, teleradiology services were available and were frequently used by 62.2% of neurosurgeons. A further 23.6% of departments described using smartphone screenshots of computed tomography (CT) images transmitted by multimedia messaging service (MMS), and 8.6% of images were described as sent by unencrypted email. Although 47.0% of neurosurgeons reported owning a smartphone, only 1.1% used their phone for on-call image communication. Teleradiology services were observed to be widely used by on-call neurosurgeons in Germany. Nevertheless, a significant number of departments appear to use outdated techniques or techniques that leave patient data unprotected. On-call neurosurgeons in Germany report a willingness to adopt more modern approaches, utilizing readily available smartphones or tablet technology. Georg Thieme Verlag KG Stuttgart · New York.

  15. Success and failure rates of tumor genotyping techniques in routine pathological samples with non-small-cell lung cancer.

    Science.gov (United States)

    Vanderlaan, Paul A; Yamaguchi, Norihiro; Folch, Erik; Boucher, David H; Kent, Michael S; Gangadharan, Sidharta P; Majid, Adnan; Goldstein, Michael A; Huberman, Mark S; Kocher, Olivier N; Costa, Daniel B

    2014-04-01

    Identification of some somatic molecular alterations in non-small-cell lung cancer (NSCLC) has become evidence-based practice. The success and failure rate of using commercially available tumor genotyping techniques in routine day-to-day NSCLC pathology samples is not well described. We sought to evaluate the success and failure rate of EGFR mutation, KRAS mutation, and ALK FISH in a cohort of lung cancers subjected to routine clinical tumor genotype. Clinicopathologic data, tumor genotype success and failure rates were retrospectively compiled and analyzed from 381 patient-tumor samples. From these 381 patients with lung cancer, the mean age was 65 years, 61.2% were women, 75.9% were white, 27.8% were never smokers, 73.8% had advanced NSCLC and 86.1% had adenocarcinoma histology. The tumor tissue was obtained from surgical specimens in 48.8%, core needle biopsies in 17.9%, and as cell blocks from aspirates or fluid in 33.3% of cases. Anatomic sites for tissue collection included lung (49.3%), lymph nodes (22.3%), pleura (11.8%), bone (6.0%), brain (6.0%), among others. The overall success rate for EGFR mutation analysis was 94.2%, for KRAS mutation 91.6% and for ALK FISH 91.6%. The highest failure rates were observed when the tissue was obtained from image-guided percutaneous transthoracic core-needle biopsies (31.8%, 27.3%, and 35.3% for EGFR, KRAS, and ALK tests, respectively) and bone specimens (23.1%, 15.4%, and 23.1%, respectively). In specimens obtained from bone, the failure rates were significantly higher for biopsies than resection specimens (40% vs. 0%, p=0.024 for EGFR) and for decalcified compared to non-decalcified samples (60% vs. 5.5%, p=0.021 for EGFR). Tumor genotype techniques are feasible in most samples, outside small image-guided percutaneous transthoracic core-needle biopsies and bone samples from core biopsies with decalcification, and therefore expansion of routine tumor genotype into the care of patients with NSCLC may not require special

  16. Care and Calls

    DEFF Research Database (Denmark)

    Paasch, Bettina Sletten

    on the enactment of care but also on patient safety. Nurses working in various hospital departments have developed different strategies for handling mobile phone calls when with a patient. Additional research into the ways nurses successfully or unsuccessfully enact care and ensure patient safety when they answer......In Danish hospitals, nurses have been equipped with a mobile work phone to improve their availability and efficiency. On the phones nurses receive internal and external phone conversations, patient calls, and alarms from electronic surveillance equipment. For safety reasons the phones cannot...... be switched off or silenced; they consequently ring during all activities and also during interactions with patients. A possible tension thus arises when nurses have to be both caring and sensitive towards the patient and simultaneously be efficient and available and answer their phone. The present paper...

  17. Calling under pressure: short-finned pilot whales make social calls during deep foraging dives.

    Science.gov (United States)

    Jensen, Frants H; Perez, Jacobo Marrero; Johnson, Mark; Soto, Natacha Aguilar; Madsen, Peter T

    2011-10-22

    Toothed whales rely on sound to echolocate prey and communicate with conspecifics, but little is known about how extreme pressure affects pneumatic sound production in deep-diving species with a limited air supply. The short-finned pilot whale (Globicephala macrorhynchus) is a highly social species among the deep-diving toothed whales, in which individuals socialize at the surface but leave their social group in pursuit of prey at depths of up to 1000 m. To investigate if these animals communicate acoustically at depth and test whether hydrostatic pressure affects communication signals, acoustic DTAGs logging sound, depth and orientation were attached to 12 pilot whales. Tagged whales produced tonal calls during deep foraging dives at depths of up to 800 m. Mean call output and duration decreased with depth despite the increased distance to conspecifics at the surface. This shows that the energy content of calls is lower at depths where lungs are collapsed and where the air volume available for sound generation is limited by ambient pressure. Frequency content was unaffected, providing a possible cue for group or species identification of diving whales. Social calls may be important to maintain social ties for foraging animals, but may be impacted adversely by vessel noise.

  18. Do market participants learn from conference calls?

    NARCIS (Netherlands)

    Roelofsen, E.; Verbeeten, F.; Mertens, G.

    2014-01-01

    We examine whether market participants learn from the information that is disseminated during the Q-and-A section of conference calls. Specifically, we investigate whether stock prices react to information on intangible assets provided during conference calls, and whether conference calls

  19. Laser sampling

    International Nuclear Information System (INIS)

    Gorbatenko, A A; Revina, E I

    2015-01-01

    The review is devoted to the major advances in laser sampling. The advantages and drawbacks of the technique are considered. Specific features of combinations of laser sampling with various instrumental analytical methods, primarily inductively coupled plasma mass spectrometry, are discussed. Examples of practical implementation of hybrid methods involving laser sampling as well as corresponding analytical characteristics are presented. The bibliography includes 78 references

  20. Determination of the uranium concentration in water samples by the technique of fission track recording

    International Nuclear Information System (INIS)

    Geraldo, L.P.

    1979-01-01

    The technique of fission track register was developed for the determination of micrograms of uranium. The Makrofol KG, a synthetic plastic made by Bayer, was used as the detector and the wet method was utilized. The detector calibration curve allows the determination of the uranium concentration in a sample within an interval from 8.0 to 0.4μgU/L, the total error ranging from 3.3% to 29.0% respectively. The method was used in the determination of the uranium content in various water samples, obtained from various sources like rivers, sea etc. in the state of Sao Paulo, Brazil. Results were compared with those obtained by other authors using different methods. The average concentration found in sea waters (3.27 +- 9.12μgU/l) by this method is compatible with the international average accepted value of 3.3μgU/l, irrespective of site and depth. The determination of the uranium content by fission track counting has proved to be very convenient. (Author) [pt

  1. HOW TO CALL THE CERN FIRE BRIGADE

    CERN Multimedia

    2002-01-01

    The telephone numbers of the CERN Fire Brigade are: 74444 for emergency calls 74848 for other calls Note The number 112 will stay in use for emergency calls from 'wired' telephones, however, from mobile phones it leads to non-CERN emergency services.  

  2. HOW TO CALL THE CERN FIRE BRIGADE

    CERN Multimedia

    2002-01-01

    The telephone numbers of the CERN Fire Brigade are: 74444 for emergency calls 74848 for other calls Note The number 112 will stay in use for emergency calls from 'wired' telephones, however, from mobile phones it leads to non-CERN emergency services.

  3. HOW TO CALL THE CERN FIRE BRIGADE

    CERN Multimedia

    2001-01-01

    The telephone numbers of the CERN Fire Brigade are: 74444 for emergency calls 74848 for other calls Note The number 112 will stay in use for emergency calls from 'wired' telephones, however, from mobile phones it leads to non-CERN emergency services.

  4. HOW TO CALL THE CERN FIRE BRIGADE

    CERN Multimedia

    2001-01-01

    The telephone numbers of the CERN Fire Brigade are: 74444 for emergency calls 74848 for other calls Note: the number 112 will stay in use for emergency calls from 'wired' telephones, however, from mobile phones it leads to non-CERN emergency services.

  5. Microfluidic devices for sample preparation and rapid detection of foodborne pathogens.

    Science.gov (United States)

    Kant, Krishna; Shahbazi, Mohammad-Ali; Dave, Vivek Priy; Ngo, Tien Anh; Chidambara, Vinayaka Aaydha; Than, Linh Quyen; Bang, Dang Duong; Wolff, Anders

    2018-03-10

    Rapid detection of foodborne pathogens at an early stage is imperative for preventing the outbreak of foodborne diseases, known as serious threats to human health. Conventional bacterial culturing methods for foodborne pathogen detection are time consuming, laborious, and with poor pathogen diagnosis competences. This has prompted researchers to call the current status of detection approaches into question and leverage new technologies for superior pathogen sensing outcomes. Novel strategies mainly rely on incorporating all the steps from sample preparation to detection in miniaturized devices for online monitoring of pathogens with high accuracy and sensitivity in a time-saving and cost effective manner. Lab on chip is a blooming area in diagnosis, which exploits different mechanical and biological techniques to detect very low concentrations of pathogens in food samples. This is achieved through streamlining the sample handling and concentrating procedures, which will subsequently reduce human errors and enhance the accuracy of the sensing methods. Integration of sample preparation techniques into these devices can effectively minimize the impact of complex food matrix on pathogen diagnosis and improve the limit of detections. Integration of pathogen capturing bio-receptors on microfluidic devices is a crucial step, which can facilitate recognition abilities in harsh chemical and physical conditions, offering a great commercial benefit to the food-manufacturing sector. This article reviews recent advances in current state-of-the-art of sample preparation and concentration from food matrices with focus on bacterial capturing methods and sensing technologies, along with their advantages and limitations when integrated into microfluidic devices for online rapid detection of pathogens in foods and food production line. Copyright © 2018. Published by Elsevier Inc.

  6. THD Doppler procedure for hemorrhoids: the surgical technique

    OpenAIRE

    Ratto, C.

    2013-01-01

    Transanal hemorrhoidal dearterialization (THD) is an effective treatment for hemorrhoidal disease. The ligation of hemorrhoidal arteries (called “dearterialization”) can provide a significant reduction of the arterial overflow to the hemorrhoidal piles. Plication of the redundant rectal mucosa/submucosa (called “mucopexy”) can provide a repositioning of prolapsing tissue to the anatomical site. In this paper, the surgical technique and perioperative patient management are illustrated. Followi...

  7. Acceptance factors for the use of video call via smartphone by blind people

    Directory of Open Access Journals (Sweden)

    Tamanit Chanjaraspong

    2017-01-01

    Full Text Available Using video call via smartphones is a new technology for blind people which can be applied to facilitate their daily lives. This video call technology is different from old technology and the technology acceptance has changed users' behavior in society, culture, and especially attitude toward using new technology. This research studied the intention and the need to use video call via smartphone by blind people according to the Technology Acceptance Model, a famous and widely-accepted theory for the indication of the intention to use technology. The survey data collected from a sample of 30 blind people who lived in the Bangkok Metropolitan Region and used smartphones in their daily life were analyzed using Pearson's Correlation Coefficient. The results found the perceived ease of use factor and the perceived usefulness factor have similar direction and relation. These two factors also have similar roles and relation to the attitude toward using and behavioral intention to use video call via smartphone in the daily life of blind people. The group of blind people who had not experienced using video call via smartphone had similar direction and relation in technology acceptance at a higher level than the group of blind people who had experienced except for the relation between the attitude toward using factor and the behavioral intention to use factor.

  8. Sample preparation of environmental samples using benzene synthesis followed by high-performance LSC

    International Nuclear Information System (INIS)

    Filippis, S. De; Noakes, J.E.

    1991-01-01

    Liquid scintillation counting (LSC) techniques have been widely employed as the detection method for determining environmental levels of tritium and 14 C. Since anthropogenic and nonanthropogenic inputs to the environment are a concern, sampling the environment surrounding a nuclear power facility or fuel reprocessing operation requires the collection of many different sample types, including agriculture products, water, biota, aquatic life, soil, and vegetation. These sample types are not suitable for the direct detection of tritium of 14 C for liquid scintillation techniques. Each sample type must be initially prepared in order to obtain the carbon or hydrogen component of interest and present this in a chemical form that is compatible with common chemicals used in scintillation counting applications. Converting the sample of interest to chemically pure benzene as a sample preparation technique has been widely accepted for processing samples for radiocarbon age-dating applications. The synthesized benzene is composed of the carbon or hydrogen atoms from the original sample and is ideal as a solvent for LSC with excellent photo-optical properties. Benzene synthesis followed by low-background scintillation counting can be applied to the preparation and measurement of environmental samples yielding good detection sensitivities, high radionuclide counting efficiency, and shorter preparation time. The method of benzene synthesis provides a unique approach to the preparation of a wide variety of environmental sample types using similar chemistry for all samples

  9. Outsourcing an Effective Postdischarge Call Program

    Science.gov (United States)

    Meek, Kevin L.; Williams, Paula; Unterschuetz, Caryn J.

    2018-01-01

    To improve patient satisfaction ratings and decrease readmissions, many organizations utilize internal staff to complete postdischarge calls to recently released patients. Developing, implementing, monitoring, and sustaining an effective call program can be challenging and have eluded some of the renowned medical centers in the country. Using collaboration with an outsourced vendor to bring state-of-the-art call technology and staffed with specially trained callers, health systems can achieve elevated levels of engagement and satisfaction for their patients postdischarge. PMID:29494453

  10. Calling to Nursing: Concept Analysis.

    Science.gov (United States)

    Emerson, Christie

    The aims of this article are (a) to analyze the concept of a calling as it relates nursing and (b) to develop a definition of calling to nursing with the detail and clarity needed to guide reliable and valid research. The classic steps described by Walker and Avant are used for the analysis. Literature from several disciplines is reviewed including vocational psychology, Christian career counseling, sociology, organizational management, and nursing. The analysis provides an operational definition of a calling to nursing and establishes 3 defining attributes of the concept: (a) a passionate intrinsic motivation or desire (perhaps with a religious component), (b) an aspiration to engage in nursing practice, as a means of fulfilling one's purpose in life, and (c) the desire to help others as one's purpose in life. Antecedents to the concept are personal introspection and cognitive awareness. Positive consequences to the concept are improved work meaningfulness, work engagement, career commitment, personal well-being, and satisfaction. Negative consequences of having a calling might include willingness to sacrifice well-being for work and problems with work-life balance. Following the concept analysis, philosophical assumptions, contextual factors, interdisciplinary work, research opportunities, and practice implications are discussed.

  11. Finite Volume Method for Pricing European Call Option with Regime-switching Volatility

    Science.gov (United States)

    Lista Tauryawati, Mey; Imron, Chairul; Putri, Endah RM

    2018-03-01

    In this paper, we present a finite volume method for pricing European call option using Black-Scholes equation with regime-switching volatility. In the first step, we formulate the Black-Scholes equations with regime-switching volatility. we use a finite volume method based on fitted finite volume with spatial discretization and an implicit time stepping technique for the case. We show that the regime-switching scheme can revert to the non-switching Black Scholes equation, both in theoretical evidence and numerical simulations.

  12. Validation of the Cognitive Assessment of Later Life Status (CALLS instrument: a computerized telephonic measure

    Directory of Open Access Journals (Sweden)

    Parsons Thomas D

    2007-05-01

    Full Text Available Abstract Background Brief screening tests have been developed to measure cognitive performance and dementia, yet they measure limited cognitive domains and often lack construct validity. Neuropsychological assessments, while comprehensive, are too costly and time-consuming for epidemiological studies. This study's aim was to develop a psychometrically valid telephone administered test of cognitive function in aging. Methods Using a sequential hierarchical strategy, each stage of test development did not proceed until specified criteria were met. The 30 minute Cognitive Assessment of Later Life Status (CALLS measure and a 2.5 hour in-person neuropsychological assessment were conducted with a randomly selected sample of 211 participants 65 years and older that included equivalent distributions of men and women from ethnically diverse populations. Results Overall Cronbach's coefficient alpha for the CALLS test was 0.81. A principal component analysis of the CALLS tests yielded five components. The CALLS total score was significantly correlated with four neuropsychological assessment components. Older age and having a high school education or less was significantly correlated with lower CALLS total scores. Females scored better overall than males. There were no score differences based on race. Conclusion The CALLS test is a valid measure that provides a unique opportunity to reliably and efficiently study cognitive function in large populations.

  13. Two applications of airtightness control techniques on big assemblies

    CERN Document Server

    Devallan, C; Marcellin, J

    1973-01-01

    Deals with two airtightness control techniques respectively applied on intersecting storage rings (ISR) at CERN in Geneva and on a liquid methane storage tank. These two big assemblies called for two different control techniques which use helium and ammonia respectively as tracer gas. Existing practical leakage detection techniques to meet industrial needs are discussed at the end of the article. (2 refs).

  14. Agarose gel electrophoresis of cerebrospinal fluid proteins of dogs after sample concentration using a membrane microconcentrator technique.

    Science.gov (United States)

    Gama, Fernanda Gomes Velasque; Santana, Aureo Evangelista; Filho, Eugênio de Campos; Nogueira, Cláudia Aparecida da Silva

    2007-03-01

    Cerebrospinal fluid (CSF) is produced in the cerebral ventricles through ultrafiltration of plasma and active transport mechanisms. Evaluation of proteins in CSF may provide important information about the production of immunoglobulins within the central nervous system as well as possible disturbances in the blood-brain barrier. The objective of this study was to measure the concentration and fractions of protein in CSF samples using a membrane microconcentrator technique followed by electrophoresis, and to compare the protein fractions obtained with those in serum. CSF samples from 3 healthy dogs and 3 dogs with canine distemper virus infection were concentrated using a membrane microconcentrator having a 0.5 to 30,000 d nominal molecular weight limit (Ultrafree, Millipore, Billerica, MA, USA). Protein concentration was determined before and after concentration. Agarose gel electrophoresis was done on concentrated CSF samples, serum, and serial dilutions of one of the CSF samples. Electrophoretic bands were clearly identified in densitometer tracings in CSF samples with protein concentrations as low as 1.3 g/dL. The higher CSF protein concentration in dogs with distemper was mainly the result of increased albumin concentration. The microconcentrating method used in this study enables characterization of the main protein fractions in CSF by routine electrophoresis and may be useful for interpreting the underlying cause of changes in CSF protein concentrations.

  15. Sampling or gambling

    Energy Technology Data Exchange (ETDEWEB)

    Gy, P.M.

    1981-12-01

    Sampling can be compared to no other technique. A mechanical sampler must above all be selected according to its aptitude for supressing or reducing all components of the sampling error. Sampling is said to be correct when it gives all elements making up the batch of matter submitted to sampling an uniform probability of being selected. A sampler must be correctly designed, built, installed, operated and maintained. When the conditions of sampling correctness are not strictly respected, the sampling error can no longer be controlled and can, unknown to the user, be unacceptably large: the sample is no longer representative. The implementation of an incorrect sampler is a form of gambling and this paper intends to show that at this game the user is nearly always the loser in the long run. The users' and the manufacturers' interests may diverge and the standards which should safeguard the users' interests very often fail to do so by tolerating or even recommending incorrect techniques such as the implementation of too narrow cutters traveling too fast through the stream to be sampled.

  16. Demonstration of Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-Volatile Particulate Matter (PM) Emissions

    Science.gov (United States)

    2017-03-06

    WP-201317) Demonstration of Novel Sampling Techniques for Measurement of Turbine Engine Volatile and Non-volatile Particulate Matter (PM... Engine Volatile and Non-Volatile Particulate Matter (PM) Emissions 6. AUTHOR(S) E. Corporan, M. DeWitt, C. Klingshirn, M.D. Cheng, R. Miake-Lye, J. Peck...the performance and viability of two devices to condition aircraft turbine engine exhaust to allow the accurate measurement of total (volatile and non

  17. EMERGENCY CALLS

    CERN Multimedia

    Medical Service

    2001-01-01

    IN URGENT NEED OF A DOCTOR GENEVA EMERGENCY SERVICES GENEVA AND VAUD 144 FIRE BRIGADE 118 POLICE 117 CERN FIREMEN 767-44-44 ANTI-POISONS CENTRE Open 24h/24h 01-251-51-51 Patient not fit to be moved, call family doctor, or: GP AT HOME, open 24h/24h 748-49-50 Association Of Geneva Doctors Emergency Doctors at home 07h-23h 322 20 20 Patient fit to be moved: HOPITAL CANTONAL CENTRAL 24 Micheli-du-Crest 372-33-11 ou 382-33-11 EMERGENCIES 382-33-11 ou 372-33-11 CHILDREN'S HOSPITAL 6 rue Willy-Donzé 372-33-11 MATERNITY 32 bvd.de la Cluse 382-68-16 ou 382-33-11 OPHTHALMOLOGY 22 Alcide Jentzer 382-33-11 ou 372-33-11 MEDICAL CENTRE CORNAVIN 1-3 rue du Jura 345 45 50 HOPITAL DE LA TOUR Meyrin EMERGENCIES 719-61-11 URGENCES PEDIATRIQUES 719-61-00 LA TOUR MEDICAL CENTRE 719-74-00 European Emergency Call 112 FRANCE EMERGENCY SERVICES 15 FIRE BRIGADE 18 POLICE 17 CERN FIREMEN AT HOME 00-41-22-767-44-44 ANTI-POISONS CENTRE Open 24h/24h 04-72-11-69-11 All doctors ...

  18. ToTem: a tool for variant calling pipeline optimization.

    Science.gov (United States)

    Tom, Nikola; Tom, Ondrej; Malcikova, Jitka; Pavlova, Sarka; Kubesova, Blanka; Rausch, Tobias; Kolarik, Miroslav; Benes, Vladimir; Bystry, Vojtech; Pospisilova, Sarka

    2018-06-26

    High-throughput bioinformatics analyses of next generation sequencing (NGS) data often require challenging pipeline optimization. The key problem is choosing appropriate tools and selecting the best parameters for optimal precision and recall. Here we introduce ToTem, a tool for automated pipeline optimization. ToTem is a stand-alone web application with a comprehensive graphical user interface (GUI). ToTem is written in Java and PHP with an underlying connection to a MySQL database. Its primary role is to automatically generate, execute and benchmark different variant calling pipeline settings. Our tool allows an analysis to be started from any level of the process and with the possibility of plugging almost any tool or code. To prevent an over-fitting of pipeline parameters, ToTem ensures the reproducibility of these by using cross validation techniques that penalize the final precision, recall and F-measure. The results are interpreted as interactive graphs and tables allowing an optimal pipeline to be selected, based on the user's priorities. Using ToTem, we were able to optimize somatic variant calling from ultra-deep targeted gene sequencing (TGS) data and germline variant detection in whole genome sequencing (WGS) data. ToTem is a tool for automated pipeline optimization which is freely available as a web application at  https://totem.software .

  19. Callings, Work Role Fit, Psychological Meaningfulness and Work Engagement among Teachers in Zambia

    Science.gov (United States)

    Rothmann, Sebastiaan; Hamukang'andu, Lukondo

    2013-01-01

    Our aim in this study was to investigate the relationships among a calling orientation, work role fit, psychological meaningfulness and work engagement of teachers in Zambia. A quantitative approach was followed and a cross-sectional survey was used. The sample (n = 150) included 75 basic and 75 secondary school teachers in the Choma district of…

  20. Comparison of individual and pooled stool samples for the assessment of intensity of Schistosoma mansoni and soil-transmitted helminth infections using the Kato-Katz technique.

    Science.gov (United States)

    Kure, Ashenafi; Mekonnen, Zeleke; Dana, Daniel; Bajiro, Mitiku; Ayana, Mio; Vercruysse, Jozef; Levecke, Bruno

    2015-09-24

    Our group has recently provided a proof-of-principle for the examination of pooled stool samples using McMaster technique as a strategy for the rapid assessment of intensity of soil-transmitted helminth infections (STH, Ascaris lumbricoides, Trichuris trichiura and hookworm). In the present study we evaluated this pooling strategy for the assessment of intensity of both STH and Schistosoma mansoni infections using the Kato-Katz technique. A cross-sectional survey was conducted in 360 children aged 5-18 years from six schools in Jimma Zone (southwest Ethiopia). We performed faecal egg counts (FECs) in both individual and pooled samples (pools sizes of 5, 10 and 20) to estimate the number of eggs per gram of stool (EPG) using the Kato-Katz technique. We also assessed the time to screen both individual and pooled samples. Except for hookworms, there was a significant correlation (correlation coefficient = 0.53-0.95) between the mean of individual FECs and the FECs of pooled samples for A. lumbricoides, T. trichiura and S. mansoni, regardless of the pool size. Mean FEC were 2,596 EPG, 125 EPG, 47 EPG, and 41 EPG for A. lumbricoides, T. trichiura, S. mansoni and hookworm, respectively. There was no significant difference in FECs between the examination of individual and pooled stool samples, except for hookworms. For this STH, pools of 10 resulted in a significant underestimation of infection intensity. The total time to obtain individual FECs was 65 h 5 min. For pooled FECs, this was 19 h 12 min for pools of 5, 14 h 39 min for pools of 10 and 12 h 42 min for pools of 20. The results indicate that pooling of stool sample holds also promise as a rapid assessment of infections intensity for STH and S. mansoni using the Kato-Katz technique. In this setting, the time in the laboratory was reduced by 70 % when pools of 5 instead of individual stool samples were screened.

  1. Search for Fluid Inclusions in a Carbonaceous Chondrite Using a New X-Ray Micro-Tomography Technique Combined with FIB Sampling

    Science.gov (United States)

    Tsuchiyama, A.; Miyake, A.; Zolensky, M. E.; Uesugi, K.; Nakano, T.; Takeuchi, A.; Suzuki, Y.; Yoshida, K.

    2014-01-01

    Early solar system aqueous fluids are preserved in some H chondrites as aqueous fluid inclusions in halite (e.g., [1]). Although potential fluid inclusions are also expected in carbonaceous chondrites [2], they have not been surely confirmed. In order to search for these fluid inclusions, we have developped a new X-ray micro-tomography technique combined with FIB sampling and applied this techniqu to a carbanaceous chondrite. Experimental: A polished thin section of Sutter's Mill meteorite (CM) was observed with an optical microscope and FE-SEM (JEOL 7001F) for chosing mineral grains of carbonates (mainly calcite) and sulfides (FeS and ZnS) 20-50 microns in typical size, which may have aqueous fluid inclusions. Then, a "house" similar to a cube with a roof (20-30 microns in size) is sampled from the mineral grain by using FIB (FEI Quanta 200 3DS). Then, the house was atached to a thin W-needle by FIB and imaged by a SR-based imaging microtomography system with a Fresnel zone plate at beamline BL47XU, SPring-8, Japan. One sample was imaged at two X-ray energies, 7 and 8 keV, to identify mineral phases (dual-enegy microtomography: [3]). The size of voxel (pixel in 3D) was 50-80 nm, which gave the effective spatial resolution of approx. 200 nm. A terrestrial quartz sample with an aqueous fluid inclusion with a bubble was also examined as a test sample by the same method. Results and discussion: A fluid inclusion of 5-8 microns in quartz was clearly identified in a CT image. A bubble of approx. 4 microns was also identified as refraction contrast although the X-ray absorption difference between fluid and bubble is small. Volumes of the fluid and bubble were obtained from the 3D CT images. Fourteen grains of calcite, two grains of iron sulfide and one grain of (Zn,Fe)S were examined. Ten calcite, one iron sulfide and one (Zn,Fe)S grains have inclusions >1 micron in size (the maximum: approx. 5 microns). The shapes are spherical or irregular. Tiny inclusions (tiny solid

  2. Determination of the uranium concentration in apatite by the fission - track registration technique

    International Nuclear Information System (INIS)

    D'Oliveira Cardoso, D.

    1983-01-01

    The feasibility of using the fission-track registration technique to determine the uranium content in the phosphate rock beneficiation steps carried on by CompanhiA Arafertil, Araxa, Minas Gerais, Brazil is studied. This determination is of considerable interest to the environmental control of the Arafertil installations as well as of its surroundings or of the areas where these products will be used. The so called wet method was adopted and a 10 μm polycarbonate foil, fabricated by Bayer under the trade name Makrofol KG was used as detector. From the calibration curve obtained, it was possible to determine uranium contents in sample solutions ranging from 21 to 212 μg U/1 with an accuracy of 8 to 14.7%, respectively. The results obtained demonstrated that the technique used is appropriate to the purposes previously aimed at. (Author) [pt

  3. Practical Calling Approach for Exome Array-Based Genome-Wide Association Studies in Korean Population

    Directory of Open Access Journals (Sweden)

    Tae-Joon Park

    2015-01-01

    Full Text Available Exome-based genotyping arrays are cost-effective and have recently been used as alternative platforms to whole-exome sequencing. However, the automated clustering algorithm in an exome array has a genotype calling problem in accuracy for identifying rare and low-frequency variants. To address these shortcomings, we present a practical approach for accurate genotype calling using the Illumina Infinium HumanExome BeadChip. We present comparison results and a statistical summary of our genotype data sets. Our data set comprises 14,647 Korean samples. To solve the limitation of automated clustering, we performed manual genotype clustering for the targeted identification of 46,076 variants that were identified using GenomeStudio software. To evaluate the effects of applying custom cluster files, we tested cluster files using 804 independent Korean samples and the same platform. Our study firstly suggests practical guidelines for exome chip quality control in Asian populations and provides valuable insight into an association study using exome chip.

  4. Introduction to Body Composition Assessment Using the Deuterium Dilution Technique with Analysis of Urine Samples by Isotope Ratio Mass Spectrometry

    International Nuclear Information System (INIS)

    2010-01-01

    The IAEA has fostered the more widespread use of a stable isotope technique to assess body composition in different population groups to address priority areas in public health nutrition in Member States. It has done this by supporting national and regional nutrition projects through its technical cooperation programme and coordinated research projects over many years. This publication was developed by an international group of experts to provide practical hands-on guidance in the use of this technique in settings where analysis of stable isotope ratios in biological samples is to be made by isotope ratio mass spectrometry. The publication is targeted at new users of this technique, for example nutritionists, analytical chemists and other professionals. More detailed information on the theoretical background and the practical applications of state of the art methodologies to monitor changes in body composition can be found in IAEA Human Health Series No. 3, Assessment of Body Composition and Total Energy Expenditure in Humans by Stable Isotope Techniques

  5. TPMG Northern California appointments and advice call center.

    Science.gov (United States)

    Conolly, Patricia; Levine, Leslie; Amaral, Debra J; Fireman, Bruce H; Driscoll, Tom

    2005-08-01

    Kaiser Permanente (KP) has been developing its use of call centers as a way to provide an expansive set of healthcare services to KP members efficiently and cost effectively. Since 1995, when The Permanente Medical Group (TPMG) began to consolidate primary care phone services into three physical call centers, the TPMG Appointments and Advice Call Center (AACC) has become the "front office" for primary care services across approximately 89% of Northern California. The AACC provides primary care phone service for approximately 3 million Kaiser Foundation Health Plan members in Northern California and responds to approximately 1 million calls per month across the three AACC sites. A database records each caller's identity as well as the day, time, and duration of each call; reason for calling; services provided to callers as a result of calls; and clinical outcomes of calls. We here summarize this information for the period 2000 through 2003.

  6. Evolution of advertisement calls in African clawed frogs

    Science.gov (United States)

    Tobias, Martha L.; Evans, Ben J.; Kelley, Darcy B.

    2014-01-01

    Summary For most frogs, advertisement calls are essential for reproductive success, conveying information on species identity, male quality, sexual state and location. While the evolutionary divergence of call characters has been examined in a number of species, the relative impacts of genetic drift or natural and sexual selection remain unclear. Insights into the evolutionary trajectory of vocal signals can be gained by examining how advertisement calls vary in a phylogenetic context. Evolution by genetic drift would be supported if more closely related species express more similar songs. Conversely, a poor correlation between evolutionary history and song expression would suggest evolution shaped by natural or sexual selection. Here, we measure seven song characters in 20 described and two undescribed species of African clawed frogs (genera Xenopus and Silurana) and four populations of X. laevis. We identify three call types — click, burst and trill — that can be distinguished by click number, call rate and intensity modulation. A fourth type is biphasic, consisting of two of the above. Call types vary in complexity from the simplest, a click, to the most complex, a biphasic call. Maximum parsimony analysis of variation in call type suggests that the ancestral type was of intermediate complexity. Each call type evolved independently more than once and call type is typically not shared by closely related species. These results indicate that call type is homoplasious and has low phylogenetic signal. We conclude that the evolution of call type is not due to genetic drift, but is under selective pressure. PMID:24723737

  7. Phylogenetic signal in the acoustic parameters of the advertisement calls of four clades of anurans.

    Science.gov (United States)

    Gingras, Bruno; Mohandesan, Elmira; Boko, Drasko; Fitch, W Tecumseh

    2013-07-01

    Anuran vocalizations, especially their advertisement calls, are largely species-specific and can be used to identify taxonomic affiliations. Because anurans are not vocal learners, their vocalizations are generally assumed to have a strong genetic component. This suggests that the degree of similarity between advertisement calls may be related to large-scale phylogenetic relationships. To test this hypothesis, advertisement calls from 90 species belonging to four large clades (Bufo, Hylinae, Leptodactylus, and Rana) were analyzed. Phylogenetic distances were estimated based on the DNA sequences of the 12S mitochondrial ribosomal RNA gene, and, for a subset of 49 species, on the rhodopsin gene. Mean values for five acoustic parameters (coefficient of variation of root-mean-square amplitude, dominant frequency, spectral flux, spectral irregularity, and spectral flatness) were computed for each species. We then tested for phylogenetic signal on the body-size-corrected residuals of these five parameters, using three statistical tests (Moran's I, Mantel, and Blomberg's K) and three models of genetic distance (pairwise distances, Abouheif's proximities, and the variance-covariance matrix derived from the phylogenetic tree). A significant phylogenetic signal was detected for most acoustic parameters on the 12S dataset, across statistical tests and genetic distance models, both for the entire sample of 90 species and within clades in several cases. A further analysis on a subset of 49 species using genetic distances derived from rhodopsin and from 12S broadly confirmed the results obtained on the larger sample, indicating that the phylogenetic signals observed in these acoustic parameters can be detected using a variety of genetic distance models derived either from a variable mitochondrial sequence or from a conserved nuclear gene. We found a robust relationship, in a large number of species, between anuran phylogenetic relatedness and acoustic similarity in the

  8. Final Report: Sampling-Based Algorithms for Estimating Structure in Big Data.

    Energy Technology Data Exchange (ETDEWEB)

    Matulef, Kevin Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-02-01

    The purpose of this project was to develop sampling-based algorithms to discover hidden struc- ture in massive data sets. Inferring structure in large data sets is an increasingly common task in many critical national security applications. These data sets come from myriad sources, such as network traffic, sensor data, and data generated by large-scale simulations. They are often so large that traditional data mining techniques are time consuming or even infeasible. To address this problem, we focus on a class of algorithms that do not compute an exact answer, but instead use sampling to compute an approximate answer using fewer resources. The particular class of algorithms that we focus on are streaming algorithms , so called because they are designed to handle high-throughput streams of data. Streaming algorithms have only a small amount of working storage - much less than the size of the full data stream - so they must necessarily use sampling to approximate the correct answer. We present two results: * A streaming algorithm called HyperHeadTail , that estimates the degree distribution of a graph (i.e., the distribution of the number of connections for each node in a network). The degree distribution is a fundamental graph property, but prior work on estimating the degree distribution in a streaming setting was impractical for many real-world application. We improve upon prior work by developing an algorithm that can handle streams with repeated edges, and graph structures that evolve over time. * An algorithm for the task of maintaining a weighted subsample of items in a stream, when the items must be sampled according to their weight, and the weights are dynamically changing. To our knowledge, this is the first such algorithm designed for dynamically evolving weights. We expect it may be useful as a building block for other streaming algorithms on dynamic data sets.

  9. Simulative Investigation on Spectral Efficiency of Unipolar Codes based OCDMA System using Importance Sampling Technique

    Science.gov (United States)

    Farhat, A.; Menif, M.; Rezig, H.

    2013-09-01

    This paper analyses the spectral efficiency of Optical Code Division Multiple Access (OCDMA) system using Importance Sampling (IS) technique. We consider three configurations of OCDMA system namely Direct Sequence (DS), Spectral Amplitude Coding (SAC) and Fast Frequency Hopping (FFH) that exploits the Fiber Bragg Gratings (FBG) based encoder/decoder. We evaluate the spectral efficiency of the considered system by taking into consideration the effect of different families of unipolar codes for both coherent and incoherent sources. The results show that the spectral efficiency of OCDMA system with coherent source is higher than the incoherent case. We demonstrate also that DS-OCDMA outperforms both others in terms of spectral efficiency in all conditions.

  10. Comparison of analysis techniques by liquid scintillation and Cerenkov Effect for 40K quantification in aqueous samples

    International Nuclear Information System (INIS)

    Miranda C, L.; Davila R, J. I.; Lopez del R, H.; Mireles G, F.

    2015-09-01

    In this work the counting by liquid scintillation and Cerenkov Effect to quantify 40 K in aqueous samples was used. The performance of both techniques was studied by comparing the response of three commercial liquid scintillation OptiPhase HiSafe 3, Ultima Gold Ab and OptiPhase TriSafe, the vial type and presentation conditions of the sample for counting. In liquid scintillation, the ability to form homogeneous mixtures depended on the ionic strength of the aqueous solutions. The scintillator OptiPhase HiSafe 3 showed a greater charge capacity for solutions with high ionic strength (<3.4), while the scintillator OptiSafe TriSafe no form homogeneous mixtures for solutions of ionic strength higher than 0.3. Counting efficiencies for different proportions of sample and scintillator near 100% for the scintillators OptiSafe HiSafe 3 and Ultima Gold Ab were obtained. In the counting by Cerenkov Effect, the efficiency and sensitivity depended of the vial type; polyethylene vials were more suitable for counting that the glass vials. The sample volume had not significant effect on counting efficiency, obtaining an average value of 44.8% for polyethylene vials and 37.3% for glass vials. Therefore, the liquid scintillation was more efficient and sensitive for the measurement of 40 K in aqueous solutions. (Author)

  11. Atomic resolution holography using advanced reconstruction techniques for two-dimensional detectors

    Energy Technology Data Exchange (ETDEWEB)

    Marko, M; Szakal, A; Cser, L [Neutron Spectroscopy Department, Research Institute for Solid State Physics and Optics, PO Box 49, H-1525 Budapest (Hungary); Krexner, G [Faculty of Physics, University of Vienna, Boltzmanngasse 5, A-1090 Vienna (Austria); Schefer, J, E-mail: marko@szfki.h [Laboratory for Neutron Scattering (LNS), Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)

    2010-06-15

    Atomic resolution holography is based on two concepts. Either the emitter of the radiation used is embedded in the sample (internal source concept) or, on account of the optical reciprocity law, the detector forms part of the sample (internal detector concept). In many cases, holographic objects (atoms and nuclei) simultaneously adopt the roles of both source and detector. Thus, the recorded image contains a mixture of both inside source and inside detector holograms. When reconstructing one type of hologram, the presence of the other hologram causes serious distortions. In the present work, we propose a new method, the so-called double reconstruction (DR), which not only suppresses the mutual distortions but also exploits the information content of the measured hologram more effectively. This novel approach also decreases the level of distortion arising from diffraction and statistical noise. The efficiency of the DR technique is significantly enhanced by employing two-dimensional (2D) area detectors. The power of the method is illustrated here by applying it to a real measurement on a palladium-hydrogen sample.

  12. Extended piano techniques : in theory, history and performance practice

    NARCIS (Netherlands)

    Vaes, Luc Paul Frank

    2009-01-01

    So-called "extended techniques" have suffered a consistent lack of understanding from a theoretical, historical and practical point of view. Although most of them – e.g. playing directly on the strings, cluster- and glissando-techniques – exist in a substantial part of the repertoire for the piano

  13. A comparative examination of several techniques for the routine determination of mercury in biological samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Faanhof, A.; Das, H.A.

    1978-01-01

    A comparative examination of the most important techniques for the separation of mercury from irradiated biological material was made. Procedures for routine analysis and results for standard materials are given. Activation was performed at a thermal neutron flux of approximately 5x10 12 nxcm -2 xs -1 during ( 3 ) 2 offers a convenient solution to this problem. The variation of the neutron flux with the irradiation position can be measured by the application of thin iron rings as flux monitors. Losses of mercury due to uptake in the wall of the irradiation containers are negligible. The most powerful destruction technique for large samples is that based on a stainless-steel bomb. (T. I.)

  14. Nuclear techniques for analysis of environmental samples

    International Nuclear Information System (INIS)

    1986-12-01

    The main purposes of this meeting were to establish the state-of-the-art in the field, to identify new research and development that is required to provide an adequate framework for analysis of environmental samples and to assess needs and possibilities for international cooperation in problem areas. This technical report was prepared on the subject based on the contributions made by the participants. A separate abstract was prepared for each of the 9 papers

  15. Project Management Techniques

    OpenAIRE

    Mihalache Anita; Salagean Liana

    2010-01-01

    Project management is a technique that can aid in the planning, scheduling, and monitoring of complex projects characterized by numerous, non repetitive jobs called activities. Examples of projects that would use project management include: - developing a mass rapid – transit system for a metropolitan area; - organizing the relocation of a corporate headquarters; - planning the production of a concert, film, or play; - developing and marketing a new automobile; - constructing a high – rise of...

  16. Bats from Fazenda Intervales, Southeastern Brazil: species account and comparison between different sampling methods

    Directory of Open Access Journals (Sweden)

    Christine V. Portfors

    2000-06-01

    Full Text Available Assessing the composition of an area's bat fauna is typically accomplished by using captures or by monitoring echolocation calls with bat detectors. The two methods may not provide the same data regarding species composition. Mist nets and harp traps may be biased towards sampling low flying species, and bat detectors biased towards detecting high intensity echolocators. A comparison of the bat fauna of Fazenda Intervales, southeastern Brazil, as revealed by mist nets and harp trap captures, checking roosts and by monitoring echolocation calls of flying bats illustrates this point. A total of 17 species of bats was sampled. Fourteen bat species were captured and the echolocation calls of 12 species were recorded, three of them not revealed by mist nets or harp traps. The different sampling methods provided different pictures of the bat fauna. Phyllostomid bats dominated the catches in mist nets, but in the field their echolocation calls were never detected. No single sampling approach provided a complete assessment of the bat fauna in the study area. In general, bats producing low intensity echolocation calls, such as phyllostomids, are more easily assessed by netting, and bats producing high intensity echolocation calls are better surveyed by bat detectors. The results demonstrate that a combined and varied approach to sampling is required for a complete assessment of the bat fauna of an area.

  17. 29 CFR 785.17 - On-call time.

    Science.gov (United States)

    2010-07-01

    ... On-call time. An employee who is required to remain on call on the employer's premises or so close... employee who is not required to remain on the employer's premises but is merely required to leave word at his home or with company officials where he may be reached is not working while on call. (Armour & Co...

  18. CALLING AQUARIUM LOVERS...

    CERN Multimedia

    2002-01-01

    CERN's anemones will soon be orphans. We are looking for someone willing to look after the aquarium in the main building, for one year. If you are interested, or if you would like more information, please call 73830. (The anemones living in the aquarium thank you in anticipation.)

  19. Calling 911! What role does the pediatrician play?

    Science.gov (United States)

    Grossman, Devin; Kunkov, Sergey; Kaplan, Carl; Crain, Ellen F

    2013-06-01

    The objective of this study was to compare admission rates and medical interventions among children whose caregivers called their child's primary care provider (PCP) before taking an ambulance to the pediatric emergency department (PED) versus those who did not. This was a prospective cohort study of patients brought to an urban, public hospital PED via emergency medical system (EMS). Children were included if the caregiver called 911 to have them transported via EMS and was present in the PED. The main variable was whether the child's PCP was called before EMS utilization. Study outcomes were medical interventions, such as intravenous line insertion or laboratory tests, and hospital admission. χ Test and logistic regression were used to evaluate the relationship of the main variable to the study outcomes. Six hundred fourteen patients met inclusion criteria and were enrolled. Five hundred eighty-five patients (95.3%) were reported to have a PCP. Seventy-four caregivers (12.1%) called their child's PCP before calling EMS. Two hundred seventy-seven patients (45.1%) had medical interventions performed; of these, 42 (15.2%) called their PCP (P = 0.03). Forty-two patients (6.8%) were admitted; among these, 14 (33.3%) called their PCP (P < 0.01). Adjusting for triage level, patients whose caregiver called the PCP before calling EMS were 3.2 times (95% confidence interval, 1.9-5.2 times) more likely to be admitted and 1.7 times (95% confidence interval, 1.1-2.9 times) more likely to have a medical intervention compared with patients whose caregivers did not call their child's PCP. Children were more likely to be admitted or require a medical intervention if their caregiver called their PCP before calling EMS. The availability of a PCP for telephone triage may help to optimize EMS utilization.

  20. RIA of PGFsub(2α) and PGE2 in biological samples of different origin: comparison with the mass fragmentographic technique

    International Nuclear Information System (INIS)

    Cattabeni, F.; Borghi, C.; Folco, G.C.; Nicosia, S.; Spagnuolo, C.

    1979-01-01

    The aim of this paper is to describe some results obtained measuring PGFsub(2α) and PGE 2 with bioassay, RIA and mass fragmentography in samples of different biological origin such as rat brain cortex and human urine of normal subjects and patients with Bartter's Syndrome. The results reported here clearly indicate that the assay of PGFsub(2α) and PGE 2 require an accurate validation with different analytical techniques. In fact, RIA of PGFsub(2α) gave different results if the samples were of different origin. It can be concluded that all the methods today available for PGs measurements need to be accurately validated utilizing different assays and that this validation is required everytime the sample matrix is changed. (Auth.)