WorldWideScience

Sample records for sampling studies

  1. Sample size in qualitative interview studies

    DEFF Research Database (Denmark)

    Malterud, Kirsti; Siersma, Volkert Dirk; Guassora, Ann Dorrit Kristiane

    2016-01-01

    Sample sizes must be ascertained in qualitative studies like in quantitative studies but not by the same means. The prevailing concept for sample size in qualitative studies is “saturation.” Saturation is closely tied to a specific methodology, and the term is inconsistently applied. We propose...... the concept “information power” to guide adequate sample size for qualitative studies. Information power indicates that the more information the sample holds, relevant for the actual study, the lower amount of participants is needed. We suggest that the size of a sample with sufficient information power...... and during data collection of a qualitative study is discussed....

  2. Sample size of the reference sample in a case-augmented study.

    Science.gov (United States)

    Ghosh, Palash; Dewanji, Anup

    2017-05-01

    The case-augmented study, in which a case sample is augmented with a reference (random) sample from the source population with only covariates information known, is becoming popular in different areas of applied science such as pharmacovigilance, ecology, and econometrics. In general, the case sample is available from some source (for example, hospital database, case registry, etc.); however, the reference sample is required to be drawn from the corresponding source population. The required minimum size of the reference sample is an important issue in this regard. In this work, we address the minimum sample size calculation and discuss related issues. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Influence of population versus convenience sampling on sample characteristics in studies of cognitive aging.

    Science.gov (United States)

    Brodaty, Henry; Mothakunnel, Annu; de Vel-Palumbo, Melissa; Ames, David; Ellis, Kathryn A; Reppermund, Simone; Kochan, Nicole A; Savage, Greg; Trollor, Julian N; Crawford, John; Sachdev, Perminder S

    2014-01-01

    We examined whether differences in findings of studies examining mild cognitive impairment (MCI) were associated with recruitment methods by comparing sample characteristics in two contemporaneous Australian studies, using population-based and convenience sampling. The Sydney Memory and Aging Study invited participants randomly from the electoral roll in defined geographic areas in Sydney. The Australian Imaging, Biomarkers and Lifestyle Study of Ageing recruited cognitively normal (CN) individuals via media appeals and MCI participants via referrals from clinicians in Melbourne and Perth. Demographic and cognitive variables were harmonized, and similar diagnostic criteria were applied to both samples retrospectively. CN participants recruited via convenience sampling were younger, better educated, more likely to be married and have a family history of dementia, and performed better cognitively than those recruited via population-based sampling. MCI participants recruited via population-based sampling had better memory performance and were less likely to carry the apolipoprotein E ε4 allele than clinically referred participants but did not differ on other demographic variables. A convenience sample of normal controls is likely to be younger and better functioning and that of an MCI group likely to perform worse than a purportedly random sample. Sampling bias should be considered when interpreting findings. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Treatability study sample exemption: update

    International Nuclear Information System (INIS)

    1997-01-01

    This document is a RCRA Information Brief intended to update the information in the 1991 Small-Scale Treatability Study Information Brief, and to address questions about the waste and treatability study sample exemptions that have arisen since References 3 and 5 were published

  5. [Saarland Growth Study: sampling design].

    Science.gov (United States)

    Danker-Hopfe, H; Zabransky, S

    2000-01-01

    The use of reference data to evaluate the physical development of children and adolescents is part of the daily routine in the paediatric ambulance. The construction of such reference data is based on the collection of extensive reference data. There are different kinds of reference data: cross sectional references, which are based on data collected from a big representative cross-sectional sample of the population, longitudinal references, which are based on follow-up surveys of usually smaller samples of individuals from birth to maturity, and mixed longitudinal references, which are a combination of longitudinal and cross-sectional reference data. The advantages and disadvantages of the different methods of data collection and the resulting reference data are discussed. The Saarland Growth Study was conducted for several reasons: growth processes are subject to secular changes, there are no specific reference data for children and adolescents from this part of the country and the growth charts in use in the paediatric praxis are possibly not appropriate any more. Therefore, the Saarland Growth Study served two purposes a) to create actual regional reference data and b) to create a database for future studies on secular trends in growth processes of children and adolescents from Saarland. The present contribution focusses on general remarks on the sampling design of (cross-sectional) growth surveys and its inferences for the design of the present study.

  6. Sampling pig farms at the abattoir in a cross-sectional study - Evaluation of a sampling method.

    Science.gov (United States)

    Birkegård, Anna Camilla; Halasa, Tariq; Toft, Nils

    2017-09-15

    A cross-sectional study design is relatively inexpensive, fast and easy to conduct when compared to other study designs. Careful planning is essential to obtaining a representative sample of the population, and the recommended approach is to use simple random sampling from an exhaustive list of units in the target population. This approach is rarely feasible in practice, and other sampling procedures must often be adopted. For example, when slaughter pigs are the target population, sampling the pigs on the slaughter line may be an alternative to on-site sampling at a list of farms. However, it is difficult to sample a large number of farms from an exact predefined list, due to the logistics and workflow of an abattoir. Therefore, it is necessary to have a systematic sampling procedure and to evaluate the obtained sample with respect to the study objective. We propose a method for 1) planning, 2) conducting, and 3) evaluating the representativeness and reproducibility of a cross-sectional study when simple random sampling is not possible. We used an example of a cross-sectional study with the aim of quantifying the association of antimicrobial resistance and antimicrobial consumption in Danish slaughter pigs. It was not possible to visit farms within the designated timeframe. Therefore, it was decided to use convenience sampling at the abattoir. Our approach was carried out in three steps: 1) planning: using data from meat inspection to plan at which abattoirs and how many farms to sample; 2) conducting: sampling was carried out at five abattoirs; 3) evaluation: representativeness was evaluated by comparing sampled and non-sampled farms, and the reproducibility of the study was assessed through simulated sampling based on meat inspection data from the period where the actual data collection was carried out. In the cross-sectional study samples were taken from 681 Danish pig farms, during five weeks from February to March 2015. The evaluation showed that the sampling

  7. Biological Sampling Variability Study

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-08

    There are many sources of variability that exist in the sample collection and analysis process. This paper addresses many, but not all, sources of variability. The main focus of this paper was to better understand and estimate variability due to differences between samplers. Variability between days was also studied, as well as random variability within each sampler. Experiments were performed using multiple surface materials (ceramic and stainless steel), multiple contaminant concentrations (10 spores and 100 spores), and with and without the presence of interfering material. All testing was done with sponge sticks using 10-inch by 10-inch coupons. Bacillus atrophaeus was used as the BA surrogate. Spores were deposited using wet deposition. Grime was coated on the coupons which were planned to include the interfering material (Section 3.3). Samples were prepared and analyzed at PNNL using CDC protocol (Section 3.4) and then cultured and counted. Five samplers were trained so that samples were taken using the same protocol. Each sampler randomly sampled eight coupons each day, four coupons with 10 spores deposited and four coupons with 100 spores deposited. Each day consisted of one material being tested. The clean samples (no interfering materials) were run first, followed by the dirty samples (coated with interfering material). There was a significant difference in recovery efficiency between the coupons with 10 spores deposited (mean of 48.9%) and those with 100 spores deposited (mean of 59.8%). There was no general significant difference between the clean and dirty (containing interfering material) coupons or between the two surface materials; however, there was a significant interaction between concentration amount and presence of interfering material. The recovery efficiency was close to the same for coupons with 10 spores deposited, but for the coupons with 100 spores deposited, the recovery efficiency for the dirty samples was significantly larger (65

  8. Monolith Chromatography as Sample Preparation Step in Virome Studies of Water Samples.

    Science.gov (United States)

    Gutiérrez-Aguirre, Ion; Kutnjak, Denis; Rački, Nejc; Rupar, Matevž; Ravnikar, Maja

    2018-01-01

    Viruses exist in aquatic media and many of them use this media as transmission route. Next-generation sequencing (NGS) technologies have opened new doors in virus research, allowing also to reveal a hidden diversity of viral species in aquatic environments. Not surprisingly, many of the newly discovered viruses are found in environmental fresh and marine waters. One of the problems in virome research can be the low amount of viral nucleic acids present in the sample in contrast to the background ones (host, eukaryotic, prokaryotic, environmental). Therefore, virus enrichment prior to NGS is necessary in many cases. In water samples, an added problem resides in the low concentration of viruses typically present in aquatic media. Different concentration strategies have been used to overcome such limitations. CIM monoliths are a new generation of chromatographic supports that due to their particular structural characteristics are very efficient in concentration and purification of viruses. In this chapter, we describe the use of CIM monolithic chromatography for sample preparation step in NGS studies targeting viruses in fresh or marine water. The step-by-step protocol will include a case study where CIM concentration was used to study the virome of a wastewater sample using NGS.

  9. Systematic versus random sampling in stereological studies.

    Science.gov (United States)

    West, Mark J

    2012-12-01

    The sampling that takes place at all levels of an experimental design must be random if the estimate is to be unbiased in a statistical sense. There are two fundamental ways by which one can make a random sample of the sections and positions to be probed on the sections. Using a card-sampling analogy, one can pick any card at all out of a deck of cards. This is referred to as independent random sampling because the sampling of any one card is made without reference to the position of the other cards. The other approach to obtaining a random sample would be to pick a card within a set number of cards and others at equal intervals within the deck. Systematic sampling along one axis of many biological structures is more efficient than random sampling, because most biological structures are not randomly organized. This article discusses the merits of systematic versus random sampling in stereological studies.

  10. Sample size calculations for case-control studies

    Science.gov (United States)

    This R package can be used to calculate the required samples size for unconditional multivariate analyses of unmatched case-control studies. The sample sizes are for a scalar exposure effect, such as binary, ordinal or continuous exposures. The sample sizes can also be computed for scalar interaction effects. The analyses account for the effects of potential confounder variables that are also included in the multivariate logistic model.

  11. Mars Sample Return Architecture Assessment Study

    Science.gov (United States)

    Centuori, S.; Hermosín, P.; Martín, J.; De Zaiacomo, G.; Colin, S.; Godfrey, A.; Myles, J.; Johnson, H.; Sachdev, T.; Ahmed, R.

    2018-04-01

    Current paper presents the results of ESA funded activity "Mars Sample Return Architecture Assessment Study" carried-out by DEIMOS Space, Lockheed Martin UK Ampthill, and MDA Corporation, where more than 500 mission design options have been studied.

  12. Sample size calculation in metabolic phenotyping studies.

    Science.gov (United States)

    Billoir, Elise; Navratil, Vincent; Blaise, Benjamin J

    2015-09-01

    The number of samples needed to identify significant effects is a key question in biomedical studies, with consequences on experimental designs, costs and potential discoveries. In metabolic phenotyping studies, sample size determination remains a complex step. This is due particularly to the multiple hypothesis-testing framework and the top-down hypothesis-free approach, with no a priori known metabolic target. Until now, there was no standard procedure available to address this purpose. In this review, we discuss sample size estimation procedures for metabolic phenotyping studies. We release an automated implementation of the Data-driven Sample size Determination (DSD) algorithm for MATLAB and GNU Octave. Original research concerning DSD was published elsewhere. DSD allows the determination of an optimized sample size in metabolic phenotyping studies. The procedure uses analytical data only from a small pilot cohort to generate an expanded data set. The statistical recoupling of variables procedure is used to identify metabolic variables, and their intensity distributions are estimated by Kernel smoothing or log-normal density fitting. Statistically significant metabolic variations are evaluated using the Benjamini-Yekutieli correction and processed for data sets of various sizes. Optimal sample size determination is achieved in a context of biomarker discovery (at least one statistically significant variation) or metabolic exploration (a maximum of statistically significant variations). DSD toolbox is encoded in MATLAB R2008A (Mathworks, Natick, MA) for Kernel and log-normal estimates, and in GNU Octave for log-normal estimates (Kernel density estimates are not robust enough in GNU octave). It is available at http://www.prabi.fr/redmine/projects/dsd/repository, with a tutorial at http://www.prabi.fr/redmine/projects/dsd/wiki. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  13. Neuromuscular dose-response studies: determining sample size.

    Science.gov (United States)

    Kopman, A F; Lien, C A; Naguib, M

    2011-02-01

    Investigators planning dose-response studies of neuromuscular blockers have rarely used a priori power analysis to determine the minimal sample size their protocols require. Institutional Review Boards and peer-reviewed journals now generally ask for this information. This study outlines a proposed method for meeting these requirements. The slopes of the dose-response relationships of eight neuromuscular blocking agents were determined using regression analysis. These values were substituted for γ in the Hill equation. When this is done, the coefficient of variation (COV) around the mean value of the ED₅₀ for each drug is easily calculated. Using these values, we performed an a priori one-sample two-tailed t-test of the means to determine the required sample size when the allowable error in the ED₅₀ was varied from ±10-20%. The COV averaged 22% (range 15-27%). We used a COV value of 25% in determining the sample size. If the allowable error in finding the mean ED₅₀ is ±15%, a sample size of 24 is needed to achieve a power of 80%. Increasing 'accuracy' beyond this point requires increasing greater sample sizes (e.g. an 'n' of 37 for a ±12% error). On the basis of the results of this retrospective analysis, a total sample size of not less than 24 subjects should be adequate for determining a neuromuscular blocking drug's clinical potency with a reasonable degree of assurance.

  14. Study of phosphors determination in biological samples

    International Nuclear Information System (INIS)

    Oliveira, Rosangela Magda de.

    1994-01-01

    In this paper, phosphors determination by neutron activation analysis in milk and bone samples was studied employing both instrumental and radiochemical separation methods. The analysis with radiochemistry separation consisted of the simultaneous irradiation of the samples and standards during 30 minutes, dissolution of the samples, hold back carrier, addition precipitation of phosphorus with ammonium phosphomolibdate (A.M.P.) and phosphorus-32 by counting by using Geiger-Mueller detector. The instrumental analysis consisted of the simultaneous irradiation of the samples and standards during 30 minutes, transfer of the samples into a counting planchet and measurement of the beta radiation emitted by phosphorus-32, after a suitable decay period. After the phosphorus analysis methods were established they were applied to both commercial milk and animal bone samples, and data obtained in the instrumental and radiochemical separation methods for each sample, were compared between themselves. In this work, it became possible to obtain analysis methods for phosphorus that can be applied independently of the sample quantity available, and the phosphorus content in the samples or interference that can be present in them. (author). 51 refs., 7 figs., 4 tabs

  15. Sampling study in milk storage tanks by INAA

    International Nuclear Information System (INIS)

    Santos, L.G.C.; Nadai Fernandes de, E.A.; Bacchi, M.A.; Tagliaferro, F.S.

    2008-01-01

    This study investigated the representativeness of samples for assessing chemical elements in milk bulk tanks. Milk samples were collected from a closed tank in a dairy plant and from an open top tank in a dairy farm. Samples were analyzed for chemical elements by instrumental neutron activation analysis (INAA). For both experiments, Br, Ca, Cs, K, Na, Rb and Zn did not present significant differences between samples thereby indicating the appropriateness of the sampling procedure adopted to evaluate the analytes of interest. (author)

  16. Feasibility of self-sampled dried blood spot and saliva samples sent by mail in a population-based study.

    Science.gov (United States)

    Sakhi, Amrit Kaur; Bastani, Nasser Ezzatkhah; Ellingjord-Dale, Merete; Gundersen, Thomas Erik; Blomhoff, Rune; Ursin, Giske

    2015-04-11

    In large epidemiological studies it is often challenging to obtain biological samples. Self-sampling by study participants using dried blood spots (DBS) technique has been suggested to overcome this challenge. DBS is a type of biosampling where blood samples are obtained by a finger-prick lancet, blotted and dried on filter paper. However, the feasibility and efficacy of collecting DBS samples from study participants in large-scale epidemiological studies is not known. The aim of the present study was to test the feasibility and response rate of collecting self-sampled DBS and saliva samples in a population-based study of women above 50 years of age. We determined response proportions, number of phone calls to the study center with questions about sampling, and quality of the DBS. We recruited women through a study conducted within the Norwegian Breast Cancer Screening Program. Invitations, instructions and materials were sent to 4,597 women. The data collection took place over a 3 month period in the spring of 2009. Response proportions for the collection of DBS and saliva samples were 71.0% (3,263) and 70.9% (3,258), respectively. We received 312 phone calls (7% of the 4,597 women) with questions regarding sampling. Of the 3,263 individuals that returned DBS cards, 3,038 (93.1%) had been packaged and shipped according to instructions. A total of 3,032 DBS samples were sufficient for at least one biomarker analysis (i.e. 92.9% of DBS samples received by the laboratory). 2,418 (74.1%) of the DBS cards received by the laboratory were filled with blood according to the instructions (i.e. 10 completely filled spots with up to 7 punches per spot for up to 70 separate analyses). To assess the quality of the samples, we selected and measured two biomarkers (carotenoids and vitamin D). The biomarker levels were consistent with previous reports. Collecting self-sampled DBS and saliva samples through the postal services provides a low cost, effective and feasible

  17. Lunar sample studies

    International Nuclear Information System (INIS)

    1977-01-01

    Lunar samples discussed and the nature of their analyses are: (1) an Apollo 15 breccia which is thoroughly analyzed as to the nature of the mature regolith from which it derived and the time and nature of the lithification process, (2) two Apollo 11 and one Apollo 12 basalts analyzed in terms of chemistry, Cross-Iddings-Pirsson-Washington norms, mineralogy, and petrography, (3) eight Apollo 17 mare basalts, also analyzed in terms of chemistry, Cross-Iddings-Pirsson-Washington norms, mineralogy, and petrography. The first seven are shown to be chemically similar although of two main textural groups; the eighth is seen to be distinct in both chemistry and mineralogy, (4) a troctolitic clast from a Fra Mauro breccia, analyzed and contrasted with other high-temperature lunar mineral assemblages. Two basaltic clasts from the same breccia are shown to have affinities with rock 14053, and (5) the uranium-thorium-lead systematics of three Apollo 16 samples are determined; serious terrestrial-lead contamination of the first two samples is attributed to bandsaw cutting in the lunar curatorial facility

  18. Feasibility of self-sampled dried blood spot and saliva samples sent by mail in a population-based study

    International Nuclear Information System (INIS)

    Sakhi, Amrit Kaur; Bastani, Nasser Ezzatkhah; Ellingjord-Dale, Merete; Gundersen, Thomas Erik; Blomhoff, Rune; Ursin, Giske

    2015-01-01

    In large epidemiological studies it is often challenging to obtain biological samples. Self-sampling by study participants using dried blood spots (DBS) technique has been suggested to overcome this challenge. DBS is a type of biosampling where blood samples are obtained by a finger-prick lancet, blotted and dried on filter paper. However, the feasibility and efficacy of collecting DBS samples from study participants in large-scale epidemiological studies is not known. The aim of the present study was to test the feasibility and response rate of collecting self-sampled DBS and saliva samples in a population–based study of women above 50 years of age. We determined response proportions, number of phone calls to the study center with questions about sampling, and quality of the DBS. We recruited women through a study conducted within the Norwegian Breast Cancer Screening Program. Invitations, instructions and materials were sent to 4,597 women. The data collection took place over a 3 month period in the spring of 2009. Response proportions for the collection of DBS and saliva samples were 71.0% (3,263) and 70.9% (3,258), respectively. We received 312 phone calls (7% of the 4,597 women) with questions regarding sampling. Of the 3,263 individuals that returned DBS cards, 3,038 (93.1%) had been packaged and shipped according to instructions. A total of 3,032 DBS samples were sufficient for at least one biomarker analysis (i.e. 92.9% of DBS samples received by the laboratory). 2,418 (74.1%) of the DBS cards received by the laboratory were filled with blood according to the instructions (i.e. 10 completely filled spots with up to 7 punches per spot for up to 70 separate analyses). To assess the quality of the samples, we selected and measured two biomarkers (carotenoids and vitamin D). The biomarker levels were consistent with previous reports. Collecting self-sampled DBS and saliva samples through the postal services provides a low cost, effective and feasible

  19. Sampling challenges in a study examining refugee resettlement.

    Science.gov (United States)

    Sulaiman-Hill, Cheryl Mr; Thompson, Sandra C

    2011-03-15

    As almost half of all refugees currently under United Nations protection are from Afghanistan or Iraq and significant numbers have already been resettled outside the region of origin, it is likely that future research will examine their resettlement needs. A number of methodological challenges confront researchers working with culturally and linguistically diverse groups; however, few detailed articles are available to inform other studies. The aim of this paper is to outline challenges with sampling and recruitment of socially invisible refugee groups, describing the method adopted for a mixed methods exploratory study assessing mental health, subjective wellbeing and resettlement perspectives of Afghan and Kurdish refugees living in New Zealand and Australia. Sampling strategies used in previous studies with similar refugee groups were considered before determining the approach to recruitment A snowball approach was adopted for the study, with multiple entry points into the communities being used to choose as wide a range of people as possible to provide further contacts and reduce selection bias. Census data was used to assess the representativeness of the sample. A sample of 193 former refugee participants was recruited in Christchurch (n = 98) and Perth (n = 95), 47% were of Afghan and 53% Kurdish ethnicity. A good gender balance (males 52%, females 48%) was achieved overall, mainly as a result of the sampling method used. Differences in the demographic composition of groups in each location were observed, especially in relation to the length of time spent in a refugee situation and time since arrival, reflecting variations in national humanitarian quota intakes. Although some measures were problematic, Census data comparison to assess reasonable representativeness of the study sample was generally reassuring. Snowball sampling, with multiple initiation points to reduce selection bias, was necessary to locate and identify participants, provide reassurance and

  20. Sampling challenges in a study examining refugee resettlement

    Directory of Open Access Journals (Sweden)

    Thompson Sandra C

    2011-03-01

    Full Text Available Abstract Background As almost half of all refugees currently under United Nations protection are from Afghanistan or Iraq and significant numbers have already been resettled outside the region of origin, it is likely that future research will examine their resettlement needs. A number of methodological challenges confront researchers working with culturally and linguistically diverse groups; however, few detailed articles are available to inform other studies. The aim of this paper is to outline challenges with sampling and recruitment of socially invisible refugee groups, describing the method adopted for a mixed methods exploratory study assessing mental health, subjective wellbeing and resettlement perspectives of Afghan and Kurdish refugees living in New Zealand and Australia. Sampling strategies used in previous studies with similar refugee groups were considered before determining the approach to recruitment Methods A snowball approach was adopted for the study, with multiple entry points into the communities being used to choose as wide a range of people as possible to provide further contacts and reduce selection bias. Census data was used to assess the representativeness of the sample. Results A sample of 193 former refugee participants was recruited in Christchurch (n = 98 and Perth (n = 95, 47% were of Afghan and 53% Kurdish ethnicity. A good gender balance (males 52%, females 48% was achieved overall, mainly as a result of the sampling method used. Differences in the demographic composition of groups in each location were observed, especially in relation to the length of time spent in a refugee situation and time since arrival, reflecting variations in national humanitarian quota intakes. Although some measures were problematic, Census data comparison to assess reasonable representativeness of the study sample was generally reassuring. Conclusions Snowball sampling, with multiple initiation points to reduce selection bias, was

  1. Sample Size in Qualitative Interview Studies: Guided by Information Power.

    Science.gov (United States)

    Malterud, Kirsti; Siersma, Volkert Dirk; Guassora, Ann Dorrit

    2015-11-27

    Sample sizes must be ascertained in qualitative studies like in quantitative studies but not by the same means. The prevailing concept for sample size in qualitative studies is "saturation." Saturation is closely tied to a specific methodology, and the term is inconsistently applied. We propose the concept "information power" to guide adequate sample size for qualitative studies. Information power indicates that the more information the sample holds, relevant for the actual study, the lower amount of participants is needed. We suggest that the size of a sample with sufficient information power depends on (a) the aim of the study, (b) sample specificity, (c) use of established theory, (d) quality of dialogue, and (e) analysis strategy. We present a model where these elements of information and their relevant dimensions are related to information power. Application of this model in the planning and during data collection of a qualitative study is discussed. © The Author(s) 2015.

  2. Developing Sampling Frame for Case Study: Challenges and Conditions

    Science.gov (United States)

    Ishak, Noriah Mohd; Abu Bakar, Abu Yazid

    2014-01-01

    Due to statistical analysis, the issue of random sampling is pertinent to any quantitative study. Unlike quantitative study, the elimination of inferential statistical analysis, allows qualitative researchers to be more creative in dealing with sampling issue. Since results from qualitative study cannot be generalized to the bigger population,…

  3. Sampling pig farms at the abattoir in a cross-sectional study − Evaluation of a sampling method

    DEFF Research Database (Denmark)

    Birkegård, Anna Camilla; Hisham Beshara Halasa, Tariq; Toft, Nils

    2017-01-01

    slaughter pigs. It was not possible to visit farms within the designated timeframe. Therefore, it was decided to use convenience sampling at the abattoir. Our approach was carried out in three steps: 1) planning: using data from meat inspection to plan at which abattoirs and how many farms to sample; 2......A cross-sectional study design is relatively inexpensive, fast and easy to conduct when compared to other study designs. Careful planning is essential to obtaining a representative sample of the population, and the recommended approach is to use simple random sampling from an exhaustive list...... of units in the target population. This approach is rarely feasible in practice, and other sampling procedures must often be adopted. For example, when slaughter pigs are the target population, sampling the pigs on the slaughter line may be an alternative to on-site sampling at a list of farms. However...

  4. The UK Biobank sample handling and storage validation studies.

    Science.gov (United States)

    Peakman, Tim C; Elliott, Paul

    2008-04-01

    and aims UK Biobank is a large prospective study in the United Kingdom to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. It involves the collection of blood and urine from 500 000 individuals aged between 40 and 69 years. How the samples are collected, processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. A series of validation studies was recommended to test the robustness of the draft sample handling and storage protocol. Samples of blood and urine were collected from 40 healthy volunteers and either processed immediately according to the protocol or maintained at specified temperatures (4 degrees C for all tubes with the exception of vacutainers containing acid citrate dextrose that were maintained at 18 degrees C) for 12, 24 or 36 h prior to processing. A further sample was maintained for 24 h at 4 degrees C, processed and the aliquots frozen at -80 degrees C for 20 days and then thawed under controlled conditions. The stability of the samples was compared for the different times in a wide variety of assays. The samples maintained at 4 degrees C were stable for at least 24 h after collection for a wide range of assays. Small but significant changes were observed in metabonomic studies in samples maintained at 4 degrees C for 36 h. There was no degradation of the samples for a range of biochemical assays after short-term freezing and thawing under controlled conditions. Whole blood maintained at 18 degrees C for 24 h in vacutainers containing acid citrate dextrose is suitable for viral immortalization techniques. The validation studies reported in this supplement provide justification for the sample handling and storage procedures adopted in the UK Biobank project.

  5. Statistics and sampling in transuranic studies

    International Nuclear Information System (INIS)

    Eberhardt, L.L.; Gilbert, R.O.

    1980-01-01

    The existing data on transuranics in the environment exhibit a remarkably high variability from sample to sample (coefficients of variation of 100% or greater). This chapter stresses the necessity of adequate sample size and suggests various ways to increase sampling efficiency. Objectives in sampling are regarded as being of great importance in making decisions as to sampling methodology. Four different classes of sampling methods are described: (1) descriptive sampling, (2) sampling for spatial pattern, (3) analytical sampling, and (4) sampling for modeling. A number of research needs are identified in the various sampling categories along with several problems that appear to be common to two or more such areas

  6. Sampling Key Populations for HIV Surveillance: Results From Eight Cross-Sectional Studies Using Respondent-Driven Sampling and Venue-Based Snowball Sampling.

    Science.gov (United States)

    Rao, Amrita; Stahlman, Shauna; Hargreaves, James; Weir, Sharon; Edwards, Jessie; Rice, Brian; Kochelani, Duncan; Mavimbela, Mpumelelo; Baral, Stefan

    2017-10-20

    In using regularly collected or existing surveillance data to characterize engagement in human immunodeficiency virus (HIV) services among marginalized populations, differences in sampling methods may produce different pictures of the target population and may therefore result in different priorities for response. The objective of this study was to use existing data to evaluate the sample distribution of eight studies of female sex workers (FSW) and men who have sex with men (MSM), who were recruited using different sampling approaches in two locations within Sub-Saharan Africa: Manzini, Swaziland and Yaoundé, Cameroon. MSM and FSW participants were recruited using either respondent-driven sampling (RDS) or venue-based snowball sampling. Recruitment took place between 2011 and 2016. Participants at each study site were administered a face-to-face survey to assess sociodemographics, along with the prevalence of self-reported HIV status, frequency of HIV testing, stigma, and other HIV-related characteristics. Crude and RDS-adjusted prevalence estimates were calculated. Crude prevalence estimates from the venue-based snowball samples were compared with the overlap of the RDS-adjusted prevalence estimates, between both FSW and MSM in Cameroon and Swaziland. RDS samples tended to be younger (MSM aged 18-21 years in Swaziland: 47.6% [139/310] in RDS vs 24.3% [42/173] in Snowball, in Cameroon: 47.9% [99/306] in RDS vs 20.1% [52/259] in Snowball; FSW aged 18-21 years in Swaziland 42.5% [82/325] in RDS vs 8.0% [20/249] in Snowball; in Cameroon 15.6% [75/576] in RDS vs 8.1% [25/306] in Snowball). They were less educated (MSM: primary school completed or less in Swaziland 42.6% [109/310] in RDS vs 4.0% [7/173] in Snowball, in Cameroon 46.2% [138/306] in RDS vs 14.3% [37/259] in Snowball; FSW: primary school completed or less in Swaziland 86.6% [281/325] in RDS vs 23.9% [59/247] in Snowball, in Cameroon 87.4% [520/576] in RDS vs 77.5% [238/307] in Snowball) than the snowball

  7. Sample size estimation and sampling techniques for selecting a representative sample

    Directory of Open Access Journals (Sweden)

    Aamir Omair

    2014-01-01

    Full Text Available Introduction: The purpose of this article is to provide a general understanding of the concepts of sampling as applied to health-related research. Sample Size Estimation: It is important to select a representative sample in quantitative research in order to be able to generalize the results to the target population. The sample should be of the required sample size and must be selected using an appropriate probability sampling technique. There are many hidden biases which can adversely affect the outcome of the study. Important factors to consider for estimating the sample size include the size of the study population, confidence level, expected proportion of the outcome variable (for categorical variables/standard deviation of the outcome variable (for numerical variables, and the required precision (margin of accuracy from the study. The more the precision required, the greater is the required sample size. Sampling Techniques: The probability sampling techniques applied for health related research include simple random sampling, systematic random sampling, stratified random sampling, cluster sampling, and multistage sampling. These are more recommended than the nonprobability sampling techniques, because the results of the study can be generalized to the target population.

  8. An Optimization Study on Listening Experiments to Improve the Comparability of Annoyance Ratings of Noise Samples from Different Experimental Sample Sets.

    Science.gov (United States)

    Di, Guoqing; Lu, Kuanguang; Shi, Xiaofan

    2018-03-08

    Annoyance ratings obtained from listening experiments are widely used in studies on health effect of environmental noise. In listening experiments, participants usually give the annoyance rating of each noise sample according to its relative annoyance degree among all samples in the experimental sample set if there are no reference sound samples, which leads to poor comparability between experimental results obtained from different experimental sample sets. To solve this problem, this study proposed to add several pink noise samples with certain loudness levels into experimental sample sets as reference sound samples. On this basis, the standard curve between logarithmic mean annoyance and loudness level of pink noise was used to calibrate the experimental results and the calibration procedures were described in detail. Furthermore, as a case study, six different types of noise sample sets were selected to conduct listening experiments using this method to examine the applicability of it. Results showed that the differences in the annoyance ratings of each identical noise sample from different experimental sample sets were markedly decreased after calibration. The determination coefficient ( R ²) of linear fitting functions between psychoacoustic annoyance (PA) and mean annoyance (MA) of noise samples from different experimental sample sets increased obviously after calibration. The case study indicated that the method above is applicable to calibrating annoyance ratings obtained from different types of noise sample sets. After calibration, the comparability of annoyance ratings of noise samples from different experimental sample sets can be distinctly improved.

  9. The Study on Mental Health at Work: Design and sampling.

    Science.gov (United States)

    Rose, Uwe; Schiel, Stefan; Schröder, Helmut; Kleudgen, Martin; Tophoven, Silke; Rauch, Angela; Freude, Gabriele; Müller, Grit

    2017-08-01

    The Study on Mental Health at Work (S-MGA) generates the first nationwide representative survey enabling the exploration of the relationship between working conditions, mental health and functioning. This paper describes the study design, sampling procedures and data collection, and presents a summary of the sample characteristics. S-MGA is a representative study of German employees aged 31-60 years subject to social security contributions. The sample was drawn from the employment register based on a two-stage cluster sampling procedure. Firstly, 206 municipalities were randomly selected from a pool of 12,227 municipalities in Germany. Secondly, 13,590 addresses were drawn from the selected municipalities for the purpose of conducting 4500 face-to-face interviews. The questionnaire covers psychosocial working and employment conditions, measures of mental health, work ability and functioning. Data from personal interviews were combined with employment histories from register data. Descriptive statistics of socio-demographic characteristics and logistic regressions analyses were used for comparing population, gross sample and respondents. In total, 4511 face-to-face interviews were conducted. A test for sampling bias revealed that individuals in older cohorts participated more often, while individuals with an unknown educational level, residing in major cities or with a non-German ethnic background were slightly underrepresented. There is no indication of major deviations in characteristics between the basic population and the sample of respondents. Hence, S-MGA provides representative data for research on work and health, designed as a cohort study with plans to rerun the survey 5 years after the first assessment.

  10. The Study on Mental Health at Work: Design and sampling

    Science.gov (United States)

    Rose, Uwe; Schiel, Stefan; Schröder, Helmut; Kleudgen, Martin; Tophoven, Silke; Rauch, Angela; Freude, Gabriele; Müller, Grit

    2017-01-01

    Aims: The Study on Mental Health at Work (S-MGA) generates the first nationwide representative survey enabling the exploration of the relationship between working conditions, mental health and functioning. This paper describes the study design, sampling procedures and data collection, and presents a summary of the sample characteristics. Methods: S-MGA is a representative study of German employees aged 31–60 years subject to social security contributions. The sample was drawn from the employment register based on a two-stage cluster sampling procedure. Firstly, 206 municipalities were randomly selected from a pool of 12,227 municipalities in Germany. Secondly, 13,590 addresses were drawn from the selected municipalities for the purpose of conducting 4500 face-to-face interviews. The questionnaire covers psychosocial working and employment conditions, measures of mental health, work ability and functioning. Data from personal interviews were combined with employment histories from register data. Descriptive statistics of socio-demographic characteristics and logistic regressions analyses were used for comparing population, gross sample and respondents. Results: In total, 4511 face-to-face interviews were conducted. A test for sampling bias revealed that individuals in older cohorts participated more often, while individuals with an unknown educational level, residing in major cities or with a non-German ethnic background were slightly underrepresented. Conclusions: There is no indication of major deviations in characteristics between the basic population and the sample of respondents. Hence, S-MGA provides representative data for research on work and health, designed as a cohort study with plans to rerun the survey 5 years after the first assessment. PMID:28673202

  11. Study of β-NMR for Liquid Biological Samples

    CERN Document Server

    Beattie, Caitlin

    2017-01-01

    β-NMR is an exotic form of NMR spectroscopy that allows for the characterization of matter based on the anisotropic β-decay of radioactive probe nuclei. This has been shown to be an effective spectroscopic technique for many different compounds, but its use for liquid biological samples is relatively unexplored. The work at the VITO line of ISOLDE seeks to employ this technique to study such samples. Currently, preparations are being made for an experiment to characterize DNA G-quadruplexes and their interactions with stabilizing cations. More specifically, the work in which I engaged as a summer student focused on the experiment’s liquid handling system and the stability of the relevant biological samples under vacuum.

  12. Acoustically levitated droplets: a contactless sampling method for fluorescence studies.

    Science.gov (United States)

    Leiterer, Jork; Grabolle, Markus; Rurack, Knut; Resch-Genger, Ute; Ziegler, Jan; Nann, Thomas; Panne, Ulrich

    2008-01-01

    Acoustic levitation is used as a new tool to study concentration-dependent processes in fluorescence spectroscopy. With this technique, small amounts of liquid and solid samples can be measured without the need for sample supports or containers, which often limits signal acquisition and can even alter sample properties due to interactions with the support material. We demonstrate that, because of the small sample volume, fluorescence measurements at high concentrations of an organic dye are possible without the limitation of inner-filter effects, which hamper such experiments in conventional, cuvette-based measurements. Furthermore, we show that acoustic levitation of liquid samples provides an experimentally simple way to study distance-dependent fluorescence modulations in semiconductor nanocrystals. The evaporation of the solvent during levitation leads to a continuous increase of solute concentration and can easily be monitored by laser-induced fluorescence.

  13. Audit sampling: A qualitative study on the role of statistical and non-statistical sampling approaches on audit practices in Sweden

    OpenAIRE

    Ayam, Rufus Tekoh

    2011-01-01

    PURPOSE: The two approaches to audit sampling; statistical and nonstatistical have been examined in this study. The overall purpose of the study is to explore the current extent at which statistical and nonstatistical sampling approaches are utilized by independent auditors during auditing practices. Moreover, the study also seeks to achieve two additional purposes; the first is to find out whether auditors utilize different sampling techniques when auditing SME´s (Small and Medium-Sized Ente...

  14. Assessing the precision of a time-sampling-based study among GPs: balancing sample size and measurement frequency.

    Science.gov (United States)

    van Hassel, Daniël; van der Velden, Lud; de Bakker, Dinny; van der Hoek, Lucas; Batenburg, Ronald

    2017-12-04

    Our research is based on a technique for time sampling, an innovative method for measuring the working hours of Dutch general practitioners (GPs), which was deployed in an earlier study. In this study, 1051 GPs were questioned about their activities in real time by sending them one SMS text message every 3 h during 1 week. The required sample size for this study is important for health workforce planners to know if they want to apply this method to target groups who are hard to reach or if fewer resources are available. In this time-sampling method, however, standard power analyses is not sufficient for calculating the required sample size as this accounts only for sample fluctuation and not for the fluctuation of measurements taken from every participant. We investigated the impact of the number of participants and frequency of measurements per participant upon the confidence intervals (CIs) for the hours worked per week. Statistical analyses of the time-use data we obtained from GPs were performed. Ninety-five percent CIs were calculated, using equations and simulation techniques, for various different numbers of GPs included in the dataset and for various frequencies of measurements per participant. Our results showed that the one-tailed CI, including sample and measurement fluctuation, decreased from 21 until 3 h between one and 50 GPs. As a result of the formulas to calculate CIs, the increase of the precision continued and was lower with the same additional number of GPs. Likewise, the analyses showed how the number of participants required decreased if more measurements per participant were taken. For example, one measurement per 3-h time slot during the week requires 300 GPs to achieve a CI of 1 h, while one measurement per hour requires 100 GPs to obtain the same result. The sample size needed for time-use research based on a time-sampling technique depends on the design and aim of the study. In this paper, we showed how the precision of the

  15. Generalizability of causal inference in observational studies under retrospective convenience sampling.

    Science.gov (United States)

    Hu, Zonghui; Qin, Jing

    2018-05-20

    Many observational studies adopt what we call retrospective convenience sampling (RCS). With the sample size in each arm prespecified, RCS randomly selects subjects from the treatment-inclined subpopulation into the treatment arm and those from the control-inclined into the control arm. Samples in each arm are representative of the respective subpopulation, but the proportion of the 2 subpopulations is usually not preserved in the sample data. We show in this work that, under RCS, existing causal effect estimators actually estimate the treatment effect over the sample population instead of the underlying study population. We investigate how to correct existing methods for consistent estimation of the treatment effect over the underlying population. Although RCS is adopted in medical studies for ethical and cost-effective purposes, it also has a big advantage for statistical inference: When the tendency to receive treatment is low in a study population, treatment effect estimators under RCS, with proper correction, are more efficient than their parallels under random sampling. These properties are investigated both theoretically and through numerical demonstration. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  16. Sampling strategies for tropical forest nutrient cycling studies: a case study in São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    G. Sparovek

    1997-12-01

    Full Text Available The precise sampling of soil, biological or micro climatic attributes in tropical forests, which are characterized by a high diversity of species and complex spatial variability, is a difficult task. We found few basic studies to guide sampling procedures. The objective of this study was to define a sampling strategy and data analysis for some parameters frequently used in nutrient cycling studies, i. e., litter amount, total nutrient amounts in litter and its composition (Ca, Mg, Κ, Ν and P, and soil attributes at three depths (organic matter, Ρ content, cation exchange capacity and base saturation. A natural remnant forest in the West of São Paulo State (Brazil was selected as study area and samples were collected in July, 1989. The total amount of litter and its total nutrient amounts had a high spatial independent variance. Conversely, the variance of litter composition was lower and the spatial dependency was peculiar to each nutrient. The sampling strategy for the estimation of litter amounts and the amount of nutrient in litter should be different than the sampling strategy for nutrient composition. For the estimation of litter amounts and the amount of nutrients in litter (related to quantity a large number of randomly distributed determinations are needed. Otherwise, for the estimation of litter nutrient composition (related to quality a smaller amount of spatially located samples should be analyzed. The determination of sampling for soil attributes differed according to the depth. Overall, surface samples (0-5 cm showed high short distance spatial dependent variance, whereas, subsurface samples exhibited spatial dependency in longer distances. Short transects with sampling interval of 5-10 m are recommended for surface sampling. Subsurface samples must also be spatially located, but with transects or grids with longer distances between sampling points over the entire area. Composite soil samples would not provide a complete

  17. [A comparison of convenience sampling and purposive sampling].

    Science.gov (United States)

    Suen, Lee-Jen Wu; Huang, Hui-Man; Lee, Hao-Hsien

    2014-06-01

    Convenience sampling and purposive sampling are two different sampling methods. This article first explains sampling terms such as target population, accessible population, simple random sampling, intended sample, actual sample, and statistical power analysis. These terms are then used to explain the difference between "convenience sampling" and purposive sampling." Convenience sampling is a non-probabilistic sampling technique applicable to qualitative or quantitative studies, although it is most frequently used in quantitative studies. In convenience samples, subjects more readily accessible to the researcher are more likely to be included. Thus, in quantitative studies, opportunity to participate is not equal for all qualified individuals in the target population and study results are not necessarily generalizable to this population. As in all quantitative studies, increasing the sample size increases the statistical power of the convenience sample. In contrast, purposive sampling is typically used in qualitative studies. Researchers who use this technique carefully select subjects based on study purpose with the expectation that each participant will provide unique and rich information of value to the study. As a result, members of the accessible population are not interchangeable and sample size is determined by data saturation not by statistical power analysis.

  18. Experimental study of glass sampling devices

    International Nuclear Information System (INIS)

    Jouan, A.; Moncouyoux, J.P.; Meyere, A.

    1992-01-01

    Two high-level liquid waste containment glass sampling systems have been designed and built. The first device fits entirely inside a standard glass storage canister, and may thus be used in facilities not initially designed for this function. It has been tested successfully in the nonradioactive prototype unit at Marcoule. The work primarily covered the design and construction of an articulated arm supporting the sampling vessel, and the mechanisms necessary for filling the vessel and recovering the sample. System actuation and operation are fully automatic, and the resulting sample is representative of the glass melt. Implementation of the device is delicate however, and its reliability is estimated at about 75%. A second device was designed specifically for new vitrification facilities. It is installed directly on the glass melting furnace, and meets process operating and quality control requirements. Tests conducted at the Marcoule prototype vitrification facility demonstrated the feasibility of the system. Special attention was given to the sampling vessel transfer mechanisms, with two filling and controlled sample cooling options

  19. Sample Size Calculations for Population Size Estimation Studies Using Multiplier Methods With Respondent-Driven Sampling Surveys.

    Science.gov (United States)

    Fearon, Elizabeth; Chabata, Sungai T; Thompson, Jennifer A; Cowan, Frances M; Hargreaves, James R

    2017-09-14

    While guidance exists for obtaining population size estimates using multiplier methods with respondent-driven sampling surveys, we lack specific guidance for making sample size decisions. To guide the design of multiplier method population size estimation studies using respondent-driven sampling surveys to reduce the random error around the estimate obtained. The population size estimate is obtained by dividing the number of individuals receiving a service or the number of unique objects distributed (M) by the proportion of individuals in a representative survey who report receipt of the service or object (P). We have developed an approach to sample size calculation, interpreting methods to estimate the variance around estimates obtained using multiplier methods in conjunction with research into design effects and respondent-driven sampling. We describe an application to estimate the number of female sex workers in Harare, Zimbabwe. There is high variance in estimates. Random error around the size estimate reflects uncertainty from M and P, particularly when the estimate of P in the respondent-driven sampling survey is low. As expected, sample size requirements are higher when the design effect of the survey is assumed to be greater. We suggest a method for investigating the effects of sample size on the precision of a population size estimate obtained using multipler methods and respondent-driven sampling. Uncertainty in the size estimate is high, particularly when P is small, so balancing against other potential sources of bias, we advise researchers to consider longer service attendance reference periods and to distribute more unique objects, which is likely to result in a higher estimate of P in the respondent-driven sampling survey. ©Elizabeth Fearon, Sungai T Chabata, Jennifer A Thompson, Frances M Cowan, James R Hargreaves. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 14.09.2017.

  20. Sample Size and Saturation in PhD Studies Using Qualitative Interviews

    Directory of Open Access Journals (Sweden)

    Mark Mason

    2010-08-01

    Full Text Available A number of issues can affect sample size in qualitative research; however, the guiding principle should be the concept of saturation. This has been explored in detail by a number of authors but is still hotly debated, and some say little understood. A sample of PhD studies using qualitative approaches, and qualitative interviews as the method of data collection was taken from theses.com and contents analysed for their sample sizes. Five hundred and sixty studies were identified that fitted the inclusion criteria. Results showed that the mean sample size was 31; however, the distribution was non-random, with a statistically significant proportion of studies, presenting sample sizes that were multiples of ten. These results are discussed in relation to saturation. They suggest a pre-meditated approach that is not wholly congruent with the principles of qualitative research. URN: urn:nbn:de:0114-fqs100387

  1. Mobile Variable Depth Sampling System Design Study

    International Nuclear Information System (INIS)

    BOGER, R.M.

    2000-01-01

    A design study is presented for a mobile, variable depth sampling system (MVDSS) that will support the treatment and immobilization of Hanford LAW and HLW. The sampler can be deployed in a 4-inch tank riser and has a design that is based on requirements identified in the Level 2 Specification (latest revision). The waste feed sequence for the MVDSS is based on Phase 1, Case 3S6 waste feed sequence. Technical information is also presented that supports the design study

  2. Mobile Variable Depth Sampling System Design Study

    Energy Technology Data Exchange (ETDEWEB)

    BOGER, R.M.

    2000-08-25

    A design study is presented for a mobile, variable depth sampling system (MVDSS) that will support the treatment and immobilization of Hanford LAW and HLW. The sampler can be deployed in a 4-inch tank riser and has a design that is based on requirements identified in the Level 2 Specification (latest revision). The waste feed sequence for the MVDSS is based on Phase 1, Case 3S6 waste feed sequence. Technical information is also presented that supports the design study.

  3. Experimental Study of Impregnation Birch and Aspen Samples

    Directory of Open Access Journals (Sweden)

    Igor Vladislavovich Grigorev

    2014-10-01

    Full Text Available An experimental study of wood impregnation was implemented by applying centrifugal methods. The impregnants were a 10% aqueous solution of potassium chloride and a 2% aqueous solution of borax. Birch (Betula pendula and aspen (Populus tremula wood samples in different moisture content were tested. The impregnation time in the centrifugal device were 30 seconds repeated 21 times, and the samples were measured after every 30 seconds. The experimental results were fitted to a nonlinear filtration law, which indicated that the centrifugal wood impregnation was dependent on wood species, wood moisture, rotational speed, and radius. Determination of rotational speed and centrifuge radius for impregnating aspen and birch at varying lengths and humidity under conditions of the nonlinear impregnant filtration law can be done using the example charts that were developed and presented in this study.

  4. Sample size for post-marketing safety studies based on historical controls.

    Science.gov (United States)

    Wu, Yu-te; Makuch, Robert W

    2010-08-01

    As part of a drug's entire life cycle, post-marketing studies are an important part in the identification of rare, serious adverse events. Recently, the US Food and Drug Administration (FDA) has begun to implement new post-marketing safety mandates as a consequence of increased emphasis on safety. The purpose of this research is to provide exact sample size formula for the proposed hybrid design, based on a two-group cohort study with incorporation of historical external data. Exact sample size formula based on the Poisson distribution is developed, because the detection of rare events is our outcome of interest. Performance of exact method is compared to its approximate large-sample theory counterpart. The proposed hybrid design requires a smaller sample size compared to the standard, two-group prospective study design. In addition, the exact method reduces the number of subjects required in the treatment group by up to 30% compared to the approximate method for the study scenarios examined. The proposed hybrid design satisfies the advantages and rationale of the two-group design with smaller sample sizes generally required. 2010 John Wiley & Sons, Ltd.

  5. Sampling methods for the study of pneumococcal carriage: a systematic review.

    Science.gov (United States)

    Gladstone, R A; Jefferies, J M; Faust, S N; Clarke, S C

    2012-11-06

    Streptococcus pneumoniae is an important pathogen worldwide. Accurate sampling of S. pneumoniae carriage is central to surveillance studies before and following conjugate vaccination programmes to combat pneumococcal disease. Any bias introduced during sampling will affect downstream recovery and typing. Many variables exist for the method of collection and initial processing, which can make inter-laboratory or international comparisons of data complex. In February 2003, a World Health Organisation working group published a standard method for the detection of pneumococcal carriage for vaccine trials to reduce or eliminate variability. We sought to describe the variables associated with the sampling of S. pneumoniae from collection to storage in the context of the methods recommended by the WHO and those used in pneumococcal carriage studies since its publication. A search of published literature in the online PubMed database was performed on the 1st June 2012, to identify published studies that collected pneumococcal carriage isolates, conducted after the publication of the WHO standard method. After undertaking a systematic analysis of the literature, we show that a number of differences in pneumococcal sampling protocol continue to exist between studies since the WHO publication. The majority of studies sample from the nasopharynx, but the choice of swab and swab transport media is more variable between studies. At present there is insufficient experimental data that supports the optimal sensitivity of any standard method. This may have contributed to incomplete adoption of the primary stages of the WHO detection protocol, alongside pragmatic or logistical issues associated with study design. Consequently studies may not provide a true estimate of pneumococcal carriage. Optimal sampling of carriage could lead to improvements in downstream analysis and the evaluation of pneumococcal vaccine impact and extrapolation to pneumococcal disease control therefore

  6. Adaptive list sequential sampling method for population-based observational studies

    NARCIS (Netherlands)

    Hof, Michel H.; Ravelli, Anita C. J.; Zwinderman, Aeilko H.

    2014-01-01

    In population-based observational studies, non-participation and delayed response to the invitation to participate are complications that often arise during the recruitment of a sample. When both are not properly dealt with, the composition of the sample can be different from the desired

  7. Adult health study reference papers. Selection of the sample. Characteristics of the sample

    Energy Technology Data Exchange (ETDEWEB)

    Beebe, G W; Fujisawa, Hideo; Yamasaki, Mitsuru

    1960-12-14

    The characteristics and selection of the clinical sample have been described in some detail to provide information on the comparability of the exposure groups with respect to factors excluded from the matching criteria and to provide basic descriptive information potentially relevant to individual studies that may be done within the framework of the Adult Health Study. The characteristics under review here are age, sex, many different aspects of residence, marital status, occupation and industry, details of location and shielding ATB, acute radiation signs and symptoms, and prior ABCC medical or pathology examinations. 5 references, 57 tables.

  8. GASOLINE VEHICLE EXHAUST PARTICLE SAMPLING STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Kittelson, D; Watts, W; Johnson, J; Zarling, D Schauer,J Kasper, K; Baltensperger, U; Burtscher, H

    2003-08-24

    The University of Minnesota collaborated with the Paul Scherrer Institute, the University of Wisconsin (UWI) and Ricardo, Inc to physically and chemically characterize the exhaust plume from recruited gasoline spark ignition (SI) vehicles. The project objectives were: (1) Measure representative particle size distributions from a set of on-road SI vehicles and compare these data to similar data collected on a small subset of light-duty gasoline vehicles tested on a chassis dynamometer with a dilution tunnel using the Unified Drive Cycle, at both room temperature (cold start) and 0 C (cold-cold start). (2) Compare data collected from SI vehicles to similar data collected from Diesel engines during the Coordinating Research Council E-43 project. (3) Characterize on-road aerosol during mixed midweek traffic and Sunday midday periods and determine fleet-specific emission rates. (4) Characterize bulk- and size-segregated chemical composition of the particulate matter (PM) emitted in the exhaust from the gasoline vehicles. Particle number concentrations and size distributions are strongly influenced by dilution and sampling conditions. Laboratory methods were evaluated to dilute SI exhaust in a way that would produce size distributions that were similar to those measured during laboratory experiments. Size fractionated samples were collected for chemical analysis using a nano-microorifice uniform deposit impactor (nano-MOUDI). In addition, bulk samples were collected and analyzed. A mixture of low, mid and high mileage vehicles were recruited for testing during the study. Under steady highway cruise conditions a significant particle signature above background was not measured, but during hard accelerations number size distributions for the test fleet were similar to modern heavy-duty Diesel vehicles. Number emissions were much higher at high speed and during cold-cold starts. Fuel specific number emissions range from 1012 to 3 x 1016 particles/kg fuel. A simple

  9. Work Sampling Study of an Engineering Professor during a Regular Contract Period

    Science.gov (United States)

    Brink, Jan; McDonald, Dale B.

    2015-01-01

    Work sampling is a technique that has been employed in industry and fields such as healthcare for some time. It is a powerful technique, and an alternative to conventional stop watch time studies, used by industrial engineers to focus upon random work sampling observations. This study applies work sampling to the duties performed by an individual…

  10. Sample size allocation in multiregional equivalence studies.

    Science.gov (United States)

    Liao, Jason J Z; Yu, Ziji; Li, Yulan

    2018-06-17

    With the increasing globalization of drug development, the multiregional clinical trial (MRCT) has gained extensive use. The data from MRCTs could be accepted by regulatory authorities across regions and countries as the primary sources of evidence to support global marketing drug approval simultaneously. The MRCT can speed up patient enrollment and drug approval, and it makes the effective therapies available to patients all over the world simultaneously. However, there are many challenges both operationally and scientifically in conducting a drug development globally. One of many important questions to answer for the design of a multiregional study is how to partition sample size into each individual region. In this paper, two systematic approaches are proposed for the sample size allocation in a multiregional equivalence trial. A numerical evaluation and a biosimilar trial are used to illustrate the characteristics of the proposed approaches. Copyright © 2018 John Wiley & Sons, Ltd.

  11. Reproducibility of preclinical animal research improves with heterogeneity of study samples

    Science.gov (United States)

    Vogt, Lucile; Sena, Emily S.; Würbel, Hanno

    2018-01-01

    Single-laboratory studies conducted under highly standardized conditions are the gold standard in preclinical animal research. Using simulations based on 440 preclinical studies across 13 different interventions in animal models of stroke, myocardial infarction, and breast cancer, we compared the accuracy of effect size estimates between single-laboratory and multi-laboratory study designs. Single-laboratory studies generally failed to predict effect size accurately, and larger sample sizes rendered effect size estimates even less accurate. By contrast, multi-laboratory designs including as few as 2 to 4 laboratories increased coverage probability by up to 42 percentage points without a need for larger sample sizes. These findings demonstrate that within-study standardization is a major cause of poor reproducibility. More representative study samples are required to improve the external validity and reproducibility of preclinical animal research and to prevent wasting animals and resources for inconclusive research. PMID:29470495

  12. Soil sample collection and analysis for the Fugitive Dust Characterization Study

    Science.gov (United States)

    Ashbaugh, Lowell L.; Carvacho, Omar F.; Brown, Michael S.; Chow, Judith C.; Watson, John G.; Magliano, Karen C.

    A unique set of soil samples was collected as part of the Fugitive Dust Characterization Study. The study was carried out to establish whether or not source profiles could be constructed using novel analytical methods that could distinguish soil dust sources from each other. The soil sources sampled included fields planted in cotton, almond, tomato, grape, and safflower, dairy and feedlot facilities, paved and unpaved roads (both urban and rural), an agricultural staging area, disturbed land with salt buildup, and construction areas where the topsoil had been removed. The samples were collected using a systematic procedure designed to reduce sampling bias, and were stored frozen to preserve possible organic signatures. For this paper the samples were characterized by particle size (percent sand, silt, and clay), dry silt content (used in EPA-recommended fugitive dust emission factors), carbon and nitrogen content, and potential to emit both PM 10 and PM 2.5. These are not the "novel analytical methods" referred to above; rather, it was the basic characterization of the samples to use in comparing analytical methods by other scientists contracted to the California Air Resources Board. The purpose of this paper is to document the methods used to collect the samples, the collection locations, the analysis of soil type and potential to emit PM 10, and the sample variability, both within field and between fields of the same crop type.

  13. WRAP Module 1 sampling strategy and waste characterization alternatives study

    Energy Technology Data Exchange (ETDEWEB)

    Bergeson, C.L.

    1994-09-30

    The Waste Receiving and Processing Module 1 Facility is designed to examine, process, certify, and ship drums and boxes of solid wastes that have a surface dose equivalent of less than 200 mrem/h. These wastes will include low-level and transuranic wastes that are retrievably stored in the 200 Area burial grounds and facilities in addition to newly generated wastes. Certification of retrievably stored wastes processing in WRAP 1 is required to meet the waste acceptance criteria for onsite treatment and disposal of low-level waste and mixed low-level waste and the Waste Isolation Pilot Plant Waste Acceptance Criteria for the disposal of TRU waste. In addition, these wastes will need to be certified for packaging in TRUPACT-II shipping containers. Characterization of the retrievably stored waste is needed to support the certification process. Characterization data will be obtained from historical records, process knowledge, nondestructive examination nondestructive assay, visual inspection of the waste, head-gas sampling, and analysis of samples taken from the waste containers. Sample characterization refers to the method or methods that are used to test waste samples for specific analytes. The focus of this study is the sample characterization needed to accurately identify the hazardous and radioactive constituents present in the retrieved wastes that will be processed in WRAP 1. In addition, some sampling and characterization will be required to support NDA calculations and to provide an over-check for the characterization of newly generated wastes. This study results in the baseline definition of WRAP 1 sampling and analysis requirements and identifies alternative methods to meet these requirements in an efficient and economical manner.

  14. WRAP Module 1 sampling strategy and waste characterization alternatives study

    International Nuclear Information System (INIS)

    Bergeson, C.L.

    1994-01-01

    The Waste Receiving and Processing Module 1 Facility is designed to examine, process, certify, and ship drums and boxes of solid wastes that have a surface dose equivalent of less than 200 mrem/h. These wastes will include low-level and transuranic wastes that are retrievably stored in the 200 Area burial grounds and facilities in addition to newly generated wastes. Certification of retrievably stored wastes processing in WRAP 1 is required to meet the waste acceptance criteria for onsite treatment and disposal of low-level waste and mixed low-level waste and the Waste Isolation Pilot Plant Waste Acceptance Criteria for the disposal of TRU waste. In addition, these wastes will need to be certified for packaging in TRUPACT-II shipping containers. Characterization of the retrievably stored waste is needed to support the certification process. Characterization data will be obtained from historical records, process knowledge, nondestructive examination nondestructive assay, visual inspection of the waste, head-gas sampling, and analysis of samples taken from the waste containers. Sample characterization refers to the method or methods that are used to test waste samples for specific analytes. The focus of this study is the sample characterization needed to accurately identify the hazardous and radioactive constituents present in the retrieved wastes that will be processed in WRAP 1. In addition, some sampling and characterization will be required to support NDA calculations and to provide an over-check for the characterization of newly generated wastes. This study results in the baseline definition of WRAP 1 sampling and analysis requirements and identifies alternative methods to meet these requirements in an efficient and economical manner

  15. Serum Dried Samples to Detect Dengue Antibodies: A Field Study

    Directory of Open Access Journals (Sweden)

    Angelica Maldonado-Rodríguez

    2017-01-01

    Full Text Available Background. Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs. Methods. Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x. The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.

  16. Investigative studies on water contamination in Bangladesh. Primary treatment of water samples at the sampling site

    International Nuclear Information System (INIS)

    Sera, K.; Islam, Md. Shafiqul; Takatsuji, T.; Nakamura, T.; Goto, S.; Takahashi, C.; Saitoh, Y.

    2010-01-01

    Arsenic concentration in 13 well waters, 9 pond waters, 10 agricultural waters and a coconut juice taken in Comilla district, Bangladesh, where the problem of arsenic pollution is the most severe, was investigated. High-level arsenic is detected even in the well water which has been kept drinking by the people. Relatively high arsenic concentration was detected for some pond and farm waters even though the sampling was performed just after the rainy season and the waters were expected to be highly diluted. Clear relationship was observed in elemental compositions between the pond water and the coconut juice collected at the edge of the water. These results are expected to become the basic information for evaluating the risk of individual food such as cultured fishes, shrimps and farm products, and for controlling total intakes of arsenic. In order to solve the problem of transportation of water samples internationally, a simple method of target preparation performed at the sampling site was established and its validity was confirmed. All targets were prepared at the sampling sites in this study on the basis of this method. (author)

  17. Sampling strategies to measure the prevalence of common recurrent infections in longitudinal studies

    Directory of Open Access Journals (Sweden)

    Luby Stephen P

    2010-08-01

    Full Text Available Abstract Background Measuring recurrent infections such as diarrhoea or respiratory infections in epidemiological studies is a methodological challenge. Problems in measuring the incidence of recurrent infections include the episode definition, recall error, and the logistics of close follow up. Longitudinal prevalence (LP, the proportion-of-time-ill estimated by repeated prevalence measurements, is an alternative measure to incidence of recurrent infections. In contrast to incidence which usually requires continuous sampling, LP can be measured at intervals. This study explored how many more participants are needed for infrequent sampling to achieve the same study power as frequent sampling. Methods We developed a set of four empirical simulation models representing low and high risk settings with short or long episode durations. The model was used to evaluate different sampling strategies with different assumptions on recall period and recall error. Results The model identified three major factors that influence sampling strategies: (1 the clustering of episodes in individuals; (2 the duration of episodes; (3 the positive correlation between an individual's disease incidence and episode duration. Intermittent sampling (e.g. 12 times per year often requires only a slightly larger sample size compared to continuous sampling, especially in cluster-randomized trials. The collection of period prevalence data can lead to highly biased effect estimates if the exposure variable is associated with episode duration. To maximize study power, recall periods of 3 to 7 days may be preferable over shorter periods, even if this leads to inaccuracy in the prevalence estimates. Conclusion Choosing the optimal approach to measure recurrent infections in epidemiological studies depends on the setting, the study objectives, study design and budget constraints. Sampling at intervals can contribute to making epidemiological studies and trials more efficient, valid

  18. Transport studies in p-type double quantum well samples

    International Nuclear Information System (INIS)

    Hyndman, R.J.

    2000-01-01

    The motivation for the study of double quantum well samples is that the extra spatial degree of freedom can modify the ground state energies of the system, leading to new and interesting many body effects. Electron bi-layers have been widely studied but the work presented here is the first systematic study of transport properties of a p-type, double quantum well system. The samples, grown on the 311 plane, consisted of two 100A GaAs wells separated by a 30A AlAs barrier. The thin barrier in our structures, gives rise to very strong inter-layer Coulombic interactions but in contrast to electron double quantum well samples, tunnelling between the two wells is very weak. This is due to the large effective mass of holes compared with electrons. It is possible to accurately control the total density of a sample and the relative occupancy of each well using front and back gates. A systematic study of the magnetoresistance properties of the p-type bi-layers, was carried out at low temperatures and in high magnetic fields, for samples covering a range of densities. Considerable care was required to obtain reliable results as the samples were extremely susceptible to electrical shock and were prone to drift in density slowly over time. With balanced wells, the very low tunnelling in the p-type bi-layer leads to a complete absence of all odd integers in both resistance and thermopower except for the v=1 state, ( v 1/2 in each layer) where v is the total Landau level filling factor. Unlike other FQHE features the v=1 state strengthens with increased density as inter-layer interactions increase in strength over intra-layer interactions. The state is also destroyed at a critical temperature, which is much lower than the measured activation temperature. This is taken as evidence for a finite temperature phase transition predicted for the bi-layer v=1. From the experimental observations, we construct a phase diagram for the state, which agree closely with theoretical predictions

  19. Suitability of small diagnostic peripheral-blood samples for cell-therapy studies.

    Science.gov (United States)

    Stephanou, Coralea; Papasavva, Panayiota; Zachariou, Myria; Patsali, Petros; Epitropou, Marilena; Ladas, Petros; Al-Abdulla, Ruba; Christou, Soteroulla; Antoniou, Michael N; Lederer, Carsten W; Kleanthous, Marina

    2017-02-01

    Primary hematopoietic stem and progenitor cells (HSPCs) are key components of cell-based therapies for blood disorders and are thus the authentic substrate for related research. We propose that ubiquitous small-volume diagnostic samples represent a readily available and as yet untapped resource of primary patient-derived cells for cell- and gene-therapy studies. In the present study we compare isolation and storage methods for HSPCs from normal and thalassemic small-volume blood samples, considering genotype, density-gradient versus lysis-based cell isolation and cryostorage media with different serum contents. Downstream analyses include viability, recovery, differentiation in semi-solid media and performance in liquid cultures and viral transductions. We demonstrate that HSPCs isolated either by ammonium-chloride potassium (ACK)-based lysis or by gradient isolation are suitable for functional analyses in clonogenic assays, high-level HSPC expansion and efficient lentiviral transduction. For cryostorage of cells, gradient isolation is superior to ACK lysis, and cryostorage in freezing media containing 50% fetal bovine serum demonstrated good results across all tested criteria. For assays on freshly isolated cells, ACK lysis performed similar to, and for thalassemic samples better than, gradient isolation, at a fraction of the cost and hands-on time. All isolation and storage methods show considerable variation within sample groups, but this is particularly acute for density gradient isolation of thalassemic samples. This study demonstrates the suitability of small-volume blood samples for storage and preclinical studies, opening up the research field of HSPC and gene therapy to any blood diagnostic laboratory with corresponding bioethics approval for experimental use of surplus material. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  20. Large Sample Neutron Activation Analysis: A Challenge in Cultural Heritage Studies

    International Nuclear Information System (INIS)

    Stamatelatos, I.E.; Tzika, F.

    2007-01-01

    Large sample neutron activation analysis compliments and significantly extends the analytical tools available for cultural heritage and authentication studies providing unique applications of non-destructive, multi-element analysis of materials that are too precious to damage for sampling purposes, representative sampling of heterogeneous materials or even analysis of whole objects. In this work, correction factors for neutron self-shielding, gamma-ray attenuation and volume distribution of the activity in large volume samples composed of iron and ceramic material were derived. Moreover, the effect of inhomogeneity on the accuracy of the technique was examined

  1. Geochemical and mineralogical study of selected weathered samples from Olkiluoto site

    International Nuclear Information System (INIS)

    Lindberg, A.

    2009-02-01

    Optical microscopy, chemical analyses and X-ray diffraction method were used to study the influence of weathering from 11 drill core samples from shallow depths (< 25 m). The samples, 4 to 22 cm in length were drilled from Olkiluoto study site, Eurajoki, and they represent the common rock types of local bedrock: mica gneiss, tonalitic and granodioritic gneiss. Two of the samples were macroscopically unweathered and 9 of them were remarkably altered. The alteration was shown as porosity, the abundance of chlorite instead of biotite and pink, unclear feldspars. Many samples also contained red-brown hematite and fractures, some of them coated with secondary minerals, even clay. Microscopically the most visible feature of weathering was the total alteration of plagioclase and cordierite to sericite. In many samples also biotite was richly altered to chlorite and opaque minerals. Microfractures were common and they were filled by hematite, kaolinite and fine-grained muscovite (sericite). Hematite was, in some cases, also largely replacing the weathered minerals, feldspars and cordierite. Chemical alteration was not clear, because the alteration of main minerals have produced secondary minerals with almost the same chemical composition without any reasonable depleting or enrichment of certain elements. X-ray diffraction determination of samples proved, that often plagioclase was replaced by mica and biotite by chlorite. In some cases the samples contained products of chemical weathering, kaolinite and smectite. (orig.)

  2. Sample size determination for disease prevalence studies with partially validated data.

    Science.gov (United States)

    Qiu, Shi-Fang; Poon, Wai-Yin; Tang, Man-Lai

    2016-02-01

    Disease prevalence is an important topic in medical research, and its study is based on data that are obtained by classifying subjects according to whether a disease has been contracted. Classification can be conducted with high-cost gold standard tests or low-cost screening tests, but the latter are subject to the misclassification of subjects. As a compromise between the two, many research studies use partially validated datasets in which all data points are classified by fallible tests, and some of the data points are validated in the sense that they are also classified by the completely accurate gold-standard test. In this article, we investigate the determination of sample sizes for disease prevalence studies with partially validated data. We use two approaches. The first is to find sample sizes that can achieve a pre-specified power of a statistical test at a chosen significance level, and the second is to find sample sizes that can control the width of a confidence interval with a pre-specified confidence level. Empirical studies have been conducted to demonstrate the performance of various testing procedures with the proposed sample sizes. The applicability of the proposed methods are illustrated by a real-data example. © The Author(s) 2012.

  3. Preparation Of Deposited Sediment Sample By Casting Method For Environmental Study

    International Nuclear Information System (INIS)

    Hutabarat, Tommy; Ristin PI, Evarista

    2000-01-01

    The preparation of deposited sediment sample by c asting m ethod for environmental study has been carried out. This method comprises separation of size fraction and casting process. The deposited sediment samples were wet sieved to separate the size fraction of >500 mum, (250-500) mum, (125-250) mum and (63-125) mum and settling procedures were followed for the separation of (40-63) mum, (20-40) mum, (10-20) mum and o C, ashed at 450 o C, respectively. In the casting process of sample, it was used polyester rapid cure resin and methyl ethyl ketone peroxide (MEKP) hardener. The moulded sediment sample was poured onto caster, allow for 60 hours long. The aim of this method is to get the casted sample which can be used effectively, efficiently and to be avoided from contamination of each other samples. Before casting, samples were grinded up to be fine. The result shows that casting product is ready to be used for natural radionuclide analysis

  4. COMPARATIVE STUDY OF ENDOMETRIAL SAMPLING USING PIPELLE WITH HYSTEROSCOPIC-GUIDED BIOPSY

    Directory of Open Access Journals (Sweden)

    Nalina S

    2017-07-01

    Full Text Available BACKGROUND Hysteroscopic-guided biopsy is the gold standard for endometrial sampling, but it carries risk of general anaesthesia, infection and perforation, whereas Pipelle does not require anaesthesia or cervical dilatation and it allows outpatient and painless endometrial sampling. The aim of the study is to determine the reliability and accuracy of Pipelle aspiration in acquiring an adequate and representative endometrial sample and to compare its histopathology with hysteroscopic-directed biopsy. MATERIALS AND METHODS A prospective observational comparative study evaluating the role of Pipelle aspiration as an outpatient procedure in endometrial sampling of perimenopausal women with AUB. 150 perimenopausal women with clinical diagnosis of abnormal uterine bleeding were selected from the Gynaecology OPD of IOG, Chennai, between October 2014 and September 2015. They were subjected to endometrial sampling by Pipelle followed by hysteroscopic-directed biopsy. The efficacy of Pipelle was determined by correlating the histopathological results obtained from it and the hysteroscopic-directed biopsy. RESULTS The histopathology of the endometrium obtained using Pipelle’s curette showed a sensitivity of 93%, specificity of 90% in the detection of abnormal findings with PPV of 88% and NPV of 94%. However, accuracy of Pipelle is found to be less in the diagnosis of polyps and submucous fibroids with accuracy of nearing 100% when using hysteroscopy. CONCLUSION Pipelle endometrial sampling is convenient, easy, painless and safe in obtaining an adequate sample for histopathology with high sensitivity and specificity for endometrial pathologies and endometrial carcinoma.

  5. A study for natural radioactivity levels in some soil samples using gamma spectrometry

    International Nuclear Information System (INIS)

    Mohamed, Yousif Hassab El Rasoul

    1997-05-01

    The purpose of this study was to investigate a few selected soil samples and to study their natural radioactivity using gamma spectrometry. The first sample was a rock phosphate from Nuba mountains region which is being considered as a low cost fertilizer. Another sample came from Miri lake area (Nuba mountains) which is known to have elevated natural radioactivity level. The other four samples came from different other regions in Sudan for comparison. The idea was to identify the radioactive nuclides present in these soil samples, to trace their sources and to determine the activity present in them. (Author)

  6. Studies and further needed investigations on radioactive contaminants in soil samples

    International Nuclear Information System (INIS)

    Belivermis, M.; Kilic, O.; Topcuoglu, S.; Cotuk, Y.; Kalayci, G.; Pestreli, D.

    2009-01-01

    Following the Chernobyl nuclear reactor accident, the radionuclides were deposited on the marine and terrestrial environments of Turkey and other countries as wet and / or dry fallout. It is well known that, the soil is the main reservoir at the terrestrial environment. The geographic distribution of the Chernobyl radionuclides per unit area is significantly different. Many countries have drawn radiation maps using the radionuclide data of the soil samples. The radioecological monitoring study in the soil samples are also investigated in the our country. However, the exist data is limited for whole region of Turkey. In general, the type study, that make, in uncultivated soil sample use of different soil layers (0-5, 5-10, 10-20, 20-30 cm). In our previous studies, the activity concentration of gamma emitting radionuclides were determined in soil samples (0-5 cm) from the Thrace (73 sites) and East and South Marmara (100 sites) regions. Moreover, the mean values of the annual effective dose equivalent were also calculated. In literature, numerous studies have been published concerning vertical migration of 1 37Cs in uncultivated soil samples use of different soil types. However, we have not enough data on this subject. On the other hand, we want to present a previously published data on the vertical distribution of 1 37Cs radionuclide in an uncultivated site in the eastern Black Sea region. It is well known that the determination of soil to plant transfer factors of radiocesium that take account all economically crops on the soil varieties is a need to support dose assessment or countermeasure studies. Previously published IAEA reports, we determined transfer factors for some crops of 1 37Cs radionuclides in cultivated soil samples (0-20 cm depth) in the eastern Black Sea region. At the same time, we have given a new project to IAEA for the determination of transfer factor of radiocesium from soil to some crops for Akkuyu Nuclear Power Plant site.

  7. A confirmatory holding time study for purgeable VOCs in water samples

    International Nuclear Information System (INIS)

    West, O.R.; Bayne, C.K.; Siegrist, R.L.; Holden, W.H.; Bottrell, D.W.

    1996-01-01

    Analyte stability during pre-analytical storage is essential to the accurate quantification contaminants in environmental samples. This is particularly true for volatile organic compounds (VOCS) which can easily volatilize and/or degrade during sample storage. Recognizing this, regulatory agencies require water samples be collected in vials without headspace and stored at 4 degrees C, and that analyses be conducted within 14 days, 2048 even if samples are acid-preserved. Since the selection of a 14-day holding time was largely arbitrary, the appropriateness of this requirement must be re-evaluated. The goal of the study described here was to provide regulatory agencies with the necessary data to extend the maximum holding time for properly preserved VOC water samples to 28 days

  8. An international study of the performance of sample collection from patients

    NARCIS (Netherlands)

    Dzik, WH; Murphy, MF; Andreu, G; Heddle, N; Hogman, C; Kekomaki, R; Murphy, S; Shimizu, M; Smit Sibinga, C.T.

    2003-01-01

    Background and Objectives Collection of a blood sample from the correct patient is the first step in the process of safe transfusion. The aim of this international collaborative study was to assess the frequency of mislabelled and miscollected samples drawn for blood grouping. Materials and Methods

  9. Who Are We Studying? Sample Diversity in Teaching of Psychology Research

    Science.gov (United States)

    Richmond, Aaron S.; Broussard, Kristin A.; Sterns, Jillian L.; Sanders, Kristina K.; Shardy, Justin C.

    2015-01-01

    The purpose of the current study was to examine the sample diversity of empirical articles published in four premier teaching of psychology journals from 2008 to 2013. We investigated which demographic information was commonly reported and if samples were ethnically representative and whether gender was representative compared to National…

  10. A comparative study of general intelligence in Spanish and Moroccan samples.

    Science.gov (United States)

    Diaz, Amelia; Sellami, Khadija; Infanzón, Eugenia; Lanzón, Teresa; Lynn, Richard

    2012-07-01

    The aim of this study is to fill a gap in intelligence research by presenting data for the average IQ in Morocco and for a comparable sample in Spain. Adult samples were administered the Raven Standard Progressive Matrices (SPM) (Raven, Court, & Raven, 2001) and scored for the total test and for the three sub-factors of gestalt continuation, verbal-analytical reasoning and visuospatial ability identified by Lynn, Allik, and Irwing (2004). The total test and the three factors have shown satisfactory reliability. Our results for the Moroccan sample show significant relationship between general intelligence factor, gestalt continuation and visuospatial ability with education level and income. Conversely, these variables have been shown to be independent for the Spanish sample. This sample obtained significantly higher scores for the four factors assessed than the Moroccan one. These differences have been found also comparing samples with the same education levels. Finally, the errors percentage for Moroccans has been higher than for Spaniards in all the items, suggesting that the level of difficulty was higher for the Moroccan sample.

  11. Improving ambulatory saliva-sampling compliance in pregnant women: a randomized controlled study.

    Directory of Open Access Journals (Sweden)

    Julian Moeller

    Full Text Available OBJECTIVE: Noncompliance with scheduled ambulatory saliva sampling is common and has been associated with biased cortisol estimates in nonpregnant subjects. This study is the first to investigate in pregnant women strategies to improve ambulatory saliva-sampling compliance, and the association between sampling noncompliance and saliva cortisol estimates. METHODS: We instructed 64 pregnant women to collect eight scheduled saliva samples on two consecutive days each. Objective compliance with scheduled sampling times was assessed with a Medication Event Monitoring System and self-reported compliance with a paper-and-pencil diary. In a randomized controlled study, we estimated whether a disclosure intervention (informing women about objective compliance monitoring and a reminder intervention (use of acoustical reminders improved compliance. A mixed model analysis was used to estimate associations between women's objective compliance and their diurnal cortisol profiles, and between deviation from scheduled sampling and the cortisol concentration measured in the related sample. RESULTS: Self-reported compliance with a saliva-sampling protocol was 91%, and objective compliance was 70%. The disclosure intervention was associated with improved objective compliance (informed: 81%, noninformed: 60%, F(1,60  = 17.64, p<0.001, but not the reminder intervention (reminders: 68%, without reminders: 72%, F(1,60 = 0.78, p = 0.379. Furthermore, a woman's increased objective compliance was associated with a higher diurnal cortisol profile, F(2,64  = 8.22, p<0.001. Altered cortisol levels were observed in less objective compliant samples, F(1,705  = 7.38, p = 0.007, with delayed sampling associated with lower cortisol levels. CONCLUSIONS: The results suggest that in pregnant women, objective noncompliance with scheduled ambulatory saliva sampling is common and is associated with biased cortisol estimates. To improve sampling compliance, results suggest

  12. Paleomagnetic Studies of Returned Samples from Mars

    Science.gov (United States)

    Weiss, B. P.; Beaty, D. W.; McSween, H. Y.; Carrier, B. L.; Czaja, A. D.; Goreva, Y. S.; Hausrath, E.; Herd, C. D. K.; Humayun, M.; McCubbin, F. M.; McLennan, S. M.; Pratt, L. M.; Sephton, M. A.; Steele, A.

    2018-04-01

    Magnetic measurements of returned samples could transform our understanding of the martian dynamo and its connection to climatic and planetary thermal evolution and provide powerful constraints on the preservation state of sample biosignatures.

  13. A Mixed Methods Sampling Methodology for a Multisite Case Study

    Science.gov (United States)

    Sharp, Julia L.; Mobley, Catherine; Hammond, Cathy; Withington, Cairen; Drew, Sam; Stringfield, Sam; Stipanovic, Natalie

    2012-01-01

    The flexibility of mixed methods research strategies makes such approaches especially suitable for multisite case studies. Yet the utilization of mixed methods to select sites for these studies is rarely reported. The authors describe their pragmatic mixed methods approach to select a sample for their multisite mixed methods case study of a…

  14. Sampling design for the Study of Cardiovascular Risks in Adolescents (ERICA

    Directory of Open Access Journals (Sweden)

    Mauricio Teixeira Leite de Vasconcellos

    2015-05-01

    Full Text Available The Study of Cardiovascular Risk in Adolescents (ERICA aims to estimate the prevalence of cardiovascular risk factors and metabolic syndrome in adolescents (12-17 years enrolled in public and private schools of the 273 municipalities with over 100,000 inhabitants in Brazil. The study population was stratified into 32 geographical strata (27 capitals and five sets with other municipalities in each macro-region of the country and a sample of 1,251 schools was selected with probability proportional to size. In each school three combinations of shift (morning and afternoon and grade were selected, and within each of these combinations, one class was selected. All eligible students in the selected classes were included in the study. The design sampling weights were calculated by the product of the reciprocals of the inclusion probabilities in each sampling stage, and were later calibrated considering the projections of the numbers of adolescents enrolled in schools located in the geographical strata by sex and age.

  15. Bayesian sample size determination for cost-effectiveness studies with censored data.

    Directory of Open Access Journals (Sweden)

    Daniel P Beavers

    Full Text Available Cost-effectiveness models are commonly utilized to determine the combined clinical and economic impact of one treatment compared to another. However, most methods for sample size determination of cost-effectiveness studies assume fully observed costs and effectiveness outcomes, which presents challenges for survival-based studies in which censoring exists. We propose a Bayesian method for the design and analysis of cost-effectiveness data in which costs and effectiveness may be censored, and the sample size is approximated for both power and assurance. We explore two parametric models and demonstrate the flexibility of the approach to accommodate a variety of modifications to study assumptions.

  16. Surface studies of plasma processed Nb samples

    International Nuclear Information System (INIS)

    Tyagi, Puneet V.; Doleans, Marc; Hannah, Brian S.; Afanador, Ralph; Stewart, Stephen; Mammosser, John; Howell, Matthew P; Saunders, Jeffrey W; Degraff, Brian D; Kim, Sang-Ho

    2015-01-01

    Contaminants present at top surface of superconducting radio frequency (SRF) cavities can act as field emitters and restrict the cavity accelerating gradient. A room temperature in-situ plasma processing technology for SRF cavities aiming to clean hydrocarbons from inner surface of cavities has been recently developed at the Spallation Neutron Source (SNS). Surface studies of the plasma-processed Nb samples by Secondary ion mass spectrometry (SIMS) and Scanning Kelvin Probe (SKP) showed that the NeO_2 plasma processing is very effective to remove carbonaceous contaminants from top surface and improves the surface work function by 0.5 to 1.0 eV.

  17. How much will afforestation of former cropland influence soil C stocks? A synthesis of paired sampling, chronosequence sampling and repeated sampling studies

    Science.gov (United States)

    Vesterdal, Lars; Hansen, K.; Stupak, I.; Don, Axel; Poeplau, C.; Leifeld, Jens; van Wesemael, Bas

    2010-05-01

    The need for documentation of land-use change effects on soil C is high on the agenda in most signatory countries to the Kyoto Protocol. Large land areas in Europe have experienced land-use change from cropland to forest since 1990 by direct afforestation as well as abandonment and regrowth of marginally productive cropland. Soil C dynamics following land-use change remain highly uncertain due to a limited number of available studies and due to influence of interacting factors such as land use history, soil type, and climate. Common approaches for estimation of potential soil C changes following land-use change are i) paired sampling of plots with a long legacy of different land uses, ii) chronosequence studies of land-use change, and lastly iii) repeated sampling of plots subject to changed land use. This paper will synthesize the quantitative effects of cropland afforestation on soil C sequestration based on all three approaches and will report on related work within Cost 639. Paired plots of forest and cropland were used to study the general differences between soil C stocks in the two land uses. At 27 sites in Denmark distributed among different regions and soil types forest floor and mineral soil were sampled in and around soil pits. Soil C stocks were higher in forest than cropland (mean difference 22 Mg C ha-1 to 1 m depth). This difference was caused solely by the presence of a forest floor in forests; mineral soil C stocks were similar (108 vs. 109 Mg C ha-1) in the two land uses regardless of soil type and the soil layers considered. The chronosequence approach was employed in the AFFOREST project for evaluation of C sequestration in biomass and soils following afforestation of cropland. Two oak (Quercus robur) and four Norway spruce (Picea abies) afforestation chronosequences (age range 1 to 90 years) were studied in Denmark, Sweden and the Netherlands. Forest floor and mineral soil (0-25 cm) C contents were as a minimum unchanged and in most cases there

  18. Bovine liver sample preparation and micro-homogeneity study for Cu and Zn determination by solid sampling electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Nomura, Cassiana S.; Silva, Cintia S.; Nogueira, Ana R.A.; Oliveira, Pedro V.

    2005-01-01

    This work describes a systematic study for the bovine liver sample preparation for Cu and Zn determination by solid sampling electrothermal atomic absorption spectrometry. The main parameters investigated were sample drying, grinding process, particle size, sample size, microsample homogeneity, and their relationship with the precision and accuracy of the method. A bovine liver sample was prepared using different drying procedures: (1) freeze drying, and (2) drying in a household microwave oven followed by drying in a stove at 60 deg. C until constant mass. Ball and cryogenic mills were used for grinding. Less sensitive wavelengths for Cu (216.5 nm) and Zn (307.6 nm), and Zeeman-based three-field background correction for Cu were used to diminish the sensitivities. The pyrolysis and atomization temperatures adopted were 1000 deg. C and 2300 deg. C for Cu, and 700 deg. C and 1700 deg. C for Zn, respectively. For both elements, it was possible to calibrate the spectrometer with aqueous solutions. The use of 250 μg of W + 200 μg of Rh as permanent chemical modifier was imperative for Zn. Under these conditions, the characteristic mass and detection limit were 1.4 ng and 1.6 ng for Cu, and 2.8 ng and 1.3 ng for Zn, respectively. The results showed good agreement (95% confidence level) for homogeneity of the entire material (> 200 mg) when the sample was dried in microwave/stove and ground in a cryogenic mill. The microsample homogeneity study showed that Zn is more dependent on the sample pretreatment than Cu. The bovine liver sample prepared in microwave/stove and ground in a cryogenic mill presented results with the lowest relative standard deviation for Cu than Zn. Good accuracy and precision were observed for bovine liver masses higher than 40 μg for Cu and 30 μg for Zn. The concentrations of Cu and Zn in the prepared bovine liver sample were 223 mg kg - 1 and 128 mg kg - 1 , respectively. The relative standard deviations were lower than 6% (n = 5). The

  19. Systematic studies of small scintillators for new sampling calorimeter

    Indian Academy of Sciences (India)

    A new sampling calorimeter using very thin scintillators and the multi-pixel photon counter (MPPC) has been proposed to produce better position resolution for the international linear collider (ILC) experiment. As part of this R & D study, small plastic scintillators of different sizes, thickness and wrapping reflectors are ...

  20. What is the optimum sample size for the study of peatland testate amoeba assemblages?

    Science.gov (United States)

    Mazei, Yuri A; Tsyganov, Andrey N; Esaulov, Anton S; Tychkov, Alexander Yu; Payne, Richard J

    2017-10-01

    Testate amoebae are widely used in ecological and palaeoecological studies of peatlands, particularly as indicators of surface wetness. To ensure data are robust and comparable it is important to consider methodological factors which may affect results. One significant question which has not been directly addressed in previous studies is how sample size (expressed here as number of Sphagnum stems) affects data quality. In three contrasting locations in a Russian peatland we extracted samples of differing size, analysed testate amoebae and calculated a number of widely-used indices: species richness, Simpson diversity, compositional dissimilarity from the largest sample and transfer function predictions of water table depth. We found that there was a trend for larger samples to contain more species across the range of commonly-used sample sizes in ecological studies. Smaller samples sometimes failed to produce counts of testate amoebae often considered minimally adequate. It seems likely that analyses based on samples of different sizes may not produce consistent data. Decisions about sample size need to reflect trade-offs between logistics, data quality, spatial resolution and the disturbance involved in sample extraction. For most common ecological applications we suggest that samples of more than eight Sphagnum stems are likely to be desirable. Copyright © 2017 Elsevier GmbH. All rights reserved.

  1. Studies on radioactivities of dust samples in the air at high altitudes

    International Nuclear Information System (INIS)

    Kohara, Eri; Muronoi, Naohiro

    2015-01-01

    The radioactivity concentrations of airborne dust samples were studied. The samples had been collected at high altitude by the Japan Air Self-Defense Force from April 2013 to March 2014. The obtained data were used for gross beta radioactivity analysis and gamma nuclide analysis. It is shown that cesium 137 was mainly detected at the 10 km and 3 km altitude of central area of Japan in several samples. Gaseous radioiodine was not detected in all the samples. Radioactive xenon was detected but the concentration did not show significant difference to the background level. (author)

  2. Microanalysis study of archaeological mural samples containing Maya blue pigment

    International Nuclear Information System (INIS)

    Sanchez del Rio, M.; Martinetto, P.; Somogyi, A.; Reyes-Valerio, C.; Dooryhee, E.; Peltier, N.; Alianelli, L.; Moignard, B.; Pichon, L.; Calligaro, T.; Dran, J.-C.

    2004-01-01

    Elemental analysis by X-ray fluorescence and particle induced X-ray emission is applied to the study of several Mesoamerican mural samples containing blue pigments. The most characteristic blue pigment is Maya blue, a very stable organo-clay complex original from Maya culture and widely used in murals, pottery and sculptures in a vast region of Mesoamerica during the pre-hispanic time (from VIII century) and during the colonization until 1580. The mural samples come from six different archaeological sites (four pre-hispanic and two from XVI century colonial convents). The correlation between the presence of some elements and the pigment colour is discussed. From the comparative study of the elemental concentration, some conclusions are drawn on the nature of the pigments and the technology used

  3. Microanalysis study of archaeological mural samples containing Maya blue pigment

    Science.gov (United States)

    Sánchez del Río, M.; Martinetto, P.; Somogyi, A.; Reyes-Valerio, C.; Dooryhée, E.; Peltier, N.; Alianelli, L.; Moignard, B.; Pichon, L.; Calligaro, T.; Dran, J.-C.

    2004-10-01

    Elemental analysis by X-ray fluorescence and particle induced X-ray emission is applied to the study of several Mesoamerican mural samples containing blue pigments. The most characteristic blue pigment is Maya blue, a very stable organo-clay complex original from Maya culture and widely used in murals, pottery and sculptures in a vast region of Mesoamerica during the pre-hispanic time (from VIII century) and during the colonization until 1580. The mural samples come from six different archaeological sites (four pre-hispanic and two from XVI century colonial convents). The correlation between the presence of some elements and the pigment colour is discussed. From the comparative study of the elemental concentration, some conclusions are drawn on the nature of the pigments and the technology used.

  4. Microanalysis study of archaeological mural samples containing Maya blue pigment

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez del Rio, M. [ESRF, BP220, F-38043 Grenoble (France)]. E-mail: srio@esrf.fr; Martinetto, P. [Laboratoire de Cristallographie, CNRS, BP166 F-30842 Grenoble (France); Somogyi, A. [ESRF, BP220, F-38043 Grenoble (France); Reyes-Valerio, C. [INAH, Mexico DF (Mexico); Dooryhee, E. [Laboratoire de Cristallographie, CNRS, BP166 F-30842 Grenoble (France); Peltier, N. [Laboratoire de Cristallographie, CNRS, BP166 F-30842 Grenoble (France); Alianelli, L. [INFM-OGG c/o ESRF, BP220, F-38043 Grenoble Cedex (France); Moignard, B. [C2RMF, 6 Rue des Pyramides, F-75041 Paris Cedex 01 (France); Pichon, L. [C2RMF, 6 Rue des Pyramides, F-75041 Paris Cedex 01 (France); Calligaro, T. [C2RMF, 6 Rue des Pyramides, F-75041 Paris Cedex 01 (France); Dran, J.-C. [C2RMF, 6 Rue des Pyramides, F-75041 Paris Cedex 01 (France)

    2004-10-08

    Elemental analysis by X-ray fluorescence and particle induced X-ray emission is applied to the study of several Mesoamerican mural samples containing blue pigments. The most characteristic blue pigment is Maya blue, a very stable organo-clay complex original from Maya culture and widely used in murals, pottery and sculptures in a vast region of Mesoamerica during the pre-hispanic time (from VIII century) and during the colonization until 1580. The mural samples come from six different archaeological sites (four pre-hispanic and two from XVI century colonial convents). The correlation between the presence of some elements and the pigment colour is discussed. From the comparative study of the elemental concentration, some conclusions are drawn on the nature of the pigments and the technology used.

  5. A Study on the Representative Sampling Survey for Radionuclide Analysis of RI Waste

    Energy Technology Data Exchange (ETDEWEB)

    Jee, K. Y. [KAERI, Daejeon (Korea, Republic of); Kim, Juyoul; Jung, Gunhyo [FNC Tech. Co., Daejeon (Korea, Republic of)

    2007-07-15

    We developed a quantitative method for attaining a representative sample during sampling survey of RI waste. Considering a source, process, and type of RI waste, the method computes the number of sample, confidence interval, variance, and coefficient of variance. We also systematize the method of sampling survey logically and quantitatively. The result of this study can be applied to sampling survey of low- and intermediate-level waste generated from nuclear power plant during the transfer process to disposal facility.

  6. Successful Sampling Strategy Advances Laboratory Studies of NMR Logging in Unconsolidated Aquifers

    Science.gov (United States)

    Behroozmand, Ahmad A.; Knight, Rosemary; Müller-Petke, Mike; Auken, Esben; Barfod, Adrian A. S.; Ferré, Ty P. A.; Vilhelmsen, Troels N.; Johnson, Carole D.; Christiansen, Anders V.

    2017-11-01

    The nuclear magnetic resonance (NMR) technique has become popular in groundwater studies because it responds directly to the presence and mobility of water in a porous medium. There is a need to conduct laboratory experiments to aid in the development of NMR hydraulic conductivity models, as is typically done in the petroleum industry. However, the challenge has been obtaining high-quality laboratory samples from unconsolidated aquifers. At a study site in Denmark, we employed sonic drilling, which minimizes the disturbance of the surrounding material, and extracted twelve 7.6 cm diameter samples for laboratory measurements. We present a detailed comparison of the acquired laboratory and logging NMR data. The agreement observed between the laboratory and logging data suggests that the methodologies proposed in this study provide good conditions for studying NMR measurements of unconsolidated near-surface aquifers. Finally, we show how laboratory sample size and condition impact the NMR measurements.

  7. Trace element studies in bioenvironmental samples using 3-MeV protons

    International Nuclear Information System (INIS)

    Walter, R.L.; Willis, R.D.; Gutknecht, W.F.

    1974-01-01

    Trace metal compositions of a wide range of biological, environmental, medical and clinical samples were investigated using proton-induced x-ray emission analysis (PIXEA). The x-rays were detected with a Si(Li) detector and spectra from over 3000 irradiations have been recorded on magnetic tape. The chi 2 fitting code TRACE developed at our laboratory was used in a semi-automatic mode to extract abundances of elements from S to Cd. Various methods of overcoming analytical problems and specimen preparation difficulties are reported. Results from some samples for typical studies are illustrated along with the reasons for interest in the sample types

  8. Analytical study on the determination of boron in environmental water samples

    International Nuclear Information System (INIS)

    Lopez, F.J.; Gimenez, E.; Hernandez, F.

    1993-01-01

    An analytical study on the determination of boron in environmental water samples was carried out. The curcumin and carmine standard methods were compared with the most recent Azomethine-H method in order to evaluate their analytical characteristics and feasibility for the analysis of boron in water samples. Analyses of synthetic water, ground water, sea water and waste water samples were carried out and a statistical evaluation of the results was made. The Azomethine-H method was found to be the most sensitive (detection limit 0.02 mg l -1 ) and selective (no interference of commonly occurring ions in water was observed), showing also the best precision (relative standard deviation lower than 4%). Moreover, it gave good results for all types of samples analyzed. The accuracy of this method was tested by the addition of known amounts of standard solutions to different types of water samples. The slopes of standard additions and direct calibration graphs were similar and recoveries of added boron ranged from 99 to 107%. (orig.)

  9. Electron Spin Resonance (ESR) studies of returned comet nucleus samples

    International Nuclear Information System (INIS)

    Tsay, Fundow; Kim, S.S.; Liang, R.H.

    1989-01-01

    The most important objective of the Comet Nucleus Sample Returm Mission is to return samples which could reflect formation conditions and evolutionary processes in the early solar nebula. It is expected that the returned samples will consist of fine-grained silicate materials mixed with ices composed of simple molecules such as H 2 O, NH 3 , CH 4 as well as organics and/or more complex compounds. Because of the exposure to ionizing radiation from cosmic-ray, gamma-ray, and solar wind protons at low temperature, free radicals are expected to be formed and trapped in the solid ice matrices. The kind of trapped radical species together with their concentration and thermal stability can be used as a dosimeter as well as a geothermometer to determine thermal and radiation histories as well as outgassing and other possible alternation effects since the nucleus material was formed. Since free radicals that are known to contain unpaired electrons are all paramagnetic in nature, they can be readily detected and characterized in their native form by the Electron Spin Resonance (ESR) method. In fact, ESR has been shown to be a non-destructive, highly sensitive tool for the detection and characterization of paramagnetic, ferromagnetic, and radiation damage centers in terrestrial and extraterrestrial geological samples. The potential use of ESR as an effective method in the study of returned comet nucleus samples, in particular, in the analysis of fine-grained solid state icy samples is discussed

  10. Phylogenetic representativeness: a new method for evaluating taxon sampling in evolutionary studies

    Directory of Open Access Journals (Sweden)

    Passamonti Marco

    2010-04-01

    Full Text Available Abstract Background Taxon sampling is a major concern in phylogenetic studies. Incomplete, biased, or improper taxon sampling can lead to misleading results in reconstructing evolutionary relationships. Several theoretical methods are available to optimize taxon choice in phylogenetic analyses. However, most involve some knowledge about the genetic relationships of the group of interest (i.e., the ingroup, or even a well-established phylogeny itself; these data are not always available in general phylogenetic applications. Results We propose a new method to assess taxon sampling developing Clarke and Warwick statistics. This method aims to measure the "phylogenetic representativeness" of a given sample or set of samples and it is based entirely on the pre-existing available taxonomy of the ingroup, which is commonly known to investigators. Moreover, our method also accounts for instability and discordance in taxonomies. A Python-based script suite, called PhyRe, has been developed to implement all analyses we describe in this paper. Conclusions We show that this method is sensitive and allows direct discrimination between representative and unrepresentative samples. It is also informative about the addition of taxa to improve taxonomic coverage of the ingroup. Provided that the investigators' expertise is mandatory in this field, phylogenetic representativeness makes up an objective touchstone in planning phylogenetic studies.

  11. Astronaut Neil Armstrong studies rock samples during geological field trip

    Science.gov (United States)

    1969-01-01

    Astronaut Neil Armstrong, commander of the Apollo 11 lunar landing mission, studies rock samples during a geological field trip to the Quitman Mountains area near the Fort Quitman ruins in far west Texas.

  12. A review of blood sample handling and pre-processing for metabolomics studies.

    Science.gov (United States)

    Hernandes, Vinicius Veri; Barbas, Coral; Dudzik, Danuta

    2017-09-01

    Metabolomics has been found to be applicable to a wide range of clinical studies, bringing a new era for improving clinical diagnostics, early disease detection, therapy prediction and treatment efficiency monitoring. A major challenge in metabolomics, particularly untargeted studies, is the extremely diverse and complex nature of biological specimens. Despite great advances in the field there still exist fundamental needs for considering pre-analytical variability that can introduce bias to the subsequent analytical process and decrease the reliability of the results and moreover confound final research outcomes. Many researchers are mainly focused on the instrumental aspects of the biomarker discovery process, and sample related variables sometimes seem to be overlooked. To bridge the gap, critical information and standardized protocols regarding experimental design and sample handling and pre-processing are highly desired. Characterization of a range variation among sample collection methods is necessary to prevent results misinterpretation and to ensure that observed differences are not due to an experimental bias caused by inconsistencies in sample processing. Herein, a systematic discussion of pre-analytical variables affecting metabolomics studies based on blood derived samples is performed. Furthermore, we provide a set of recommendations concerning experimental design, collection, pre-processing procedures and storage conditions as a practical review that can guide and serve for the standardization of protocols and reduction of undesirable variation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Preparation of irritant polymer samples for an in vitro round robin study.

    NARCIS (Netherlands)

    Coleman, Kelly P; Grailer, Thomas P; McNamara, Lori R; Rollins, Beau L; Christiano, Nicholas J; Kandárová, Helena; De Jong, Wim H

    2018-01-01

    A round robin study using reconstructed human epidermis (RhE) tissues was conducted to test medical device polymer extracts for skin irritation potential. Test samples were four irritant and three non-irritant medical device polymers. Five of these polymer samples were developed and two were

  14. New complete sample of identified radio sources. Part 2. Statistical study

    International Nuclear Information System (INIS)

    Soltan, A.

    1978-01-01

    Complete sample of radio sources with known redshifts selected in Paper I is studied. Source counts in the sample and the luminosity - volume test show that both quasars and galaxies are subject to the evolution. Luminosity functions for different ranges of redshifts are obtained. Due to many uncertainties only simplified models of the evolution are tested. Exponential decline of the liminosity with time of all the bright sources is in a good agreement both with the luminosity- volume test and N(S) realtion in the entire range of observed flux densities. It is shown that sources in the sample are randomly distributed in scales greater than about 17 Mpc. (author)

  15. Genus-Specific Primers for Study of Fusarium Communities in Field Samples

    Science.gov (United States)

    Edel-Hermann, Véronique; Gautheron, Nadine; Durling, Mikael Brandström; Kolseth, Anna-Karin; Steinberg, Christian; Persson, Paula; Friberg, Hanna

    2015-01-01

    Fusarium is a large and diverse genus of fungi of great agricultural and economic importance, containing many plant pathogens and mycotoxin producers. To date, high-throughput sequencing of Fusarium communities has been limited by the lack of genus-specific primers targeting regions with high discriminatory power at the species level. In the present study, we evaluated two Fusarium-specific primer pairs targeting translation elongation factor 1 (TEF1). We also present the new primer pair Fa+7/Ra+6. Mock Fusarium communities reflecting phylogenetic diversity were used to evaluate the accuracy of the primers in reflecting the relative abundance of the species. TEF1 amplicons were subjected to 454 high-throughput sequencing to characterize Fusarium communities. Field samples from soil and wheat kernels were included to test the method on more-complex material. For kernel samples, a single PCR was sufficient, while for soil samples, nested PCR was necessary. The newly developed primer pairs Fa+7/Ra+6 and Fa/Ra accurately reflected Fusarium species composition in mock DNA communities. In field samples, 47 Fusarium operational taxonomic units were identified, with the highest Fusarium diversity in soil. The Fusarium community in soil was dominated by members of the Fusarium incarnatum-Fusarium equiseti species complex, contradicting findings in previous studies. The method was successfully applied to analyze Fusarium communities in soil and plant material and can facilitate further studies of Fusarium ecology. PMID:26519387

  16. Analysis of intraosseous samples in endotoxemic shock--an experimental study in the anaesthetised pig.

    Science.gov (United States)

    Strandberg, G; Larsson, A; Lipcsey, M; Berglund, L; Eriksson, M

    2014-03-01

    Intraosseous (IO) access is used in emergency situations to allow rapid initiation of treatment. IO access is also sometimes used for blood sampling, although data on accuracy of such sampling in critical illness are limited. There is also a potential risk that bone marrow fragments in IO samples may damage laboratory equipment. It is ethically questionable to perform a simultaneous comparison between IO and arterial/venous sampling in critically ill humans. We have, thus, studied the analytical performance of IO sampling in a porcine septic shock model using a cartridge-based analyser. Eight pigs with endotoxin-induced septic shock were sampled hourly for 6 h, and analysed for blood gases, acid base status, haemoglobin, glucose and lactate using point of care instruments. Samples were taken from three IO cannulae (tibia bilaterally, one with infusion, and humerus), one arterial and one venous. An interaction test was used to assess changes in agreement between methods over time. Bland–Altman plots were constructed to study bias between methods. There were, to a varying extent, differences between IO and arterial/venous levels for all studied variables, but agreement did not change significantly during the experiment. A general finding was a large dispersion of differences between methods. IO sample values should be treated with caution in this setting but may add useful information to the clinical picture. The tibia or humerus may be used for sampling. IO infusion decreases agreement, thus sampling during infusion should be avoided.

  17. [Study of spatial stratified sampling strategy of Oncomelania hupensis snail survey based on plant abundance].

    Science.gov (United States)

    Xun-Ping, W; An, Z

    2017-07-27

    Objective To optimize and simplify the survey method of Oncomelania hupensis snails in marshland endemic regions of schistosomiasis, so as to improve the precision, efficiency and economy of the snail survey. Methods A snail sampling strategy (Spatial Sampling Scenario of Oncomelania based on Plant Abundance, SOPA) which took the plant abundance as auxiliary variable was explored and an experimental study in a 50 m×50 m plot in a marshland in the Poyang Lake region was performed. Firstly, the push broom surveyed data was stratified into 5 layers by the plant abundance data; then, the required numbers of optimal sampling points of each layer through Hammond McCullagh equation were calculated; thirdly, every sample point in the line with the Multiple Directional Interpolation (MDI) placement scheme was pinpointed; and finally, the comparison study among the outcomes of the spatial random sampling strategy, the traditional systematic sampling method, the spatial stratified sampling method, Sandwich spatial sampling and inference and SOPA was performed. Results The method (SOPA) proposed in this study had the minimal absolute error of 0.213 8; and the traditional systematic sampling method had the largest estimate, and the absolute error was 0.924 4. Conclusion The snail sampling strategy (SOPA) proposed in this study obtains the higher estimation accuracy than the other four methods.

  18. Study on graphite samples for nuclear usage

    International Nuclear Information System (INIS)

    Suarez, J.C.M.; Silva Roseira, M. da

    1994-01-01

    Available as short communication only. The graphite, due to its properties (mechanical strength, thermal conductivity, high-temperature stability, machinability etc.) have many industrial applications, and consequently, an important strategic value. In the nuclear area, it has been used as moderator and reflector of neutrons in the fission process of uranium. The graphite can be produced from many types of carbonaceous materials by a variety of process dominated by the manufactures. This is the reason why there are in the world market a lot of graphite types with different physical and mechanical properties. The present investigation studies some physical characteristics of the graphite samples destined to use in a nuclear reactor. (author). 8 refs, 1 fig, 1 tab

  19. Systematic sampling with errors in sample locations

    DEFF Research Database (Denmark)

    Ziegel, Johanna; Baddeley, Adrian; Dorph-Petersen, Karl-Anton

    2010-01-01

    analysis using point process methods. We then analyze three different models for the error process, calculate exact expressions for the variances, and derive asymptotic variances. Errors in the placement of sample points can lead to substantial inflation of the variance, dampening of zitterbewegung......Systematic sampling of points in continuous space is widely used in microscopy and spatial surveys. Classical theory provides asymptotic expressions for the variance of estimators based on systematic sampling as the grid spacing decreases. However, the classical theory assumes that the sample grid...... is exactly periodic; real physical sampling procedures may introduce errors in the placement of the sample points. This paper studies the effect of errors in sample positioning on the variance of estimators in the case of one-dimensional systematic sampling. First we sketch a general approach to variance...

  20. Abortion experiences among Zanzibari women: a chain-referral sampling study

    OpenAIRE

    Norris, Alison; Harrington, Bryna J.; Grossman, Daniel; Hemed, Maryam; Hindin, Michelle J.

    2016-01-01

    Background In Zanzibar, a semi-autonomous region of Tanzania, induced abortion is illegal but common, and fewer than 12?% of married reproductive-aged women use modern contraception. As part of a multi-method study about contraception and consequences of unwanted pregnancies, the objective of this study was to understand the experiences of Zanzibari women who terminated pregnancies. Methods The cross-sectional study was set in Zanzibar, Tanzania. Participants were a community-based sample of ...

  1. What about N? A methodological study of sample-size reporting in focus group studies.

    Science.gov (United States)

    Carlsen, Benedicte; Glenton, Claire

    2011-03-11

    Focus group studies are increasingly published in health related journals, but we know little about how researchers use this method, particularly how they determine the number of focus groups to conduct. The methodological literature commonly advises researchers to follow principles of data saturation, although practical advise on how to do this is lacking. Our objectives were firstly, to describe the current status of sample size in focus group studies reported in health journals. Secondly, to assess whether and how researchers explain the number of focus groups they carry out. We searched PubMed for studies that had used focus groups and that had been published in open access journals during 2008, and extracted data on the number of focus groups and on any explanation authors gave for this number. We also did a qualitative assessment of the papers with regard to how number of groups was explained and discussed. We identified 220 papers published in 117 journals. In these papers insufficient reporting of sample sizes was common. The number of focus groups conducted varied greatly (mean 8.4, median 5, range 1 to 96). Thirty seven (17%) studies attempted to explain the number of groups. Six studies referred to rules of thumb in the literature, three stated that they were unable to organize more groups for practical reasons, while 28 studies stated that they had reached a point of saturation. Among those stating that they had reached a point of saturation, several appeared not to have followed principles from grounded theory where data collection and analysis is an iterative process until saturation is reached. Studies with high numbers of focus groups did not offer explanations for number of groups. Too much data as a study weakness was not an issue discussed in any of the reviewed papers. Based on these findings we suggest that journals adopt more stringent requirements for focus group method reporting. The often poor and inconsistent reporting seen in these

  2. What about N? A methodological study of sample-size reporting in focus group studies

    Directory of Open Access Journals (Sweden)

    Glenton Claire

    2011-03-01

    Full Text Available Abstract Background Focus group studies are increasingly published in health related journals, but we know little about how researchers use this method, particularly how they determine the number of focus groups to conduct. The methodological literature commonly advises researchers to follow principles of data saturation, although practical advise on how to do this is lacking. Our objectives were firstly, to describe the current status of sample size in focus group studies reported in health journals. Secondly, to assess whether and how researchers explain the number of focus groups they carry out. Methods We searched PubMed for studies that had used focus groups and that had been published in open access journals during 2008, and extracted data on the number of focus groups and on any explanation authors gave for this number. We also did a qualitative assessment of the papers with regard to how number of groups was explained and discussed. Results We identified 220 papers published in 117 journals. In these papers insufficient reporting of sample sizes was common. The number of focus groups conducted varied greatly (mean 8.4, median 5, range 1 to 96. Thirty seven (17% studies attempted to explain the number of groups. Six studies referred to rules of thumb in the literature, three stated that they were unable to organize more groups for practical reasons, while 28 studies stated that they had reached a point of saturation. Among those stating that they had reached a point of saturation, several appeared not to have followed principles from grounded theory where data collection and analysis is an iterative process until saturation is reached. Studies with high numbers of focus groups did not offer explanations for number of groups. Too much data as a study weakness was not an issue discussed in any of the reviewed papers. Conclusions Based on these findings we suggest that journals adopt more stringent requirements for focus group method

  3. Thermoluminescence and X-ray diffraction studies on sliced ancient porcelain samples

    International Nuclear Information System (INIS)

    Leung, P.L.; Yang, B.

    1999-01-01

    The thermal activation characteristics (TACs) of the sensitivity of the '110 deg. C' peak in 14 sliced ancient Chinese porcelain samples are studied. Comparing with the TACs of natural quartz and synthetic mullite, the relation between the TACs and the composition of the sample is discussed with reference to the X-ray diffraction (XRD) spectra. It is suggested that in some cases, contribution of the porcelain components other than quartz to the TACs is not negligible

  4. Thermoluminescence and X-ray diffraction studies on sliced ancient porcelain samples

    Energy Technology Data Exchange (ETDEWEB)

    Leung, P.L.; Yang, B. E-mail: yangbr@bnu.edu.cn

    1999-09-01

    The thermal activation characteristics (TACs) of the sensitivity of the '110 deg. C' peak in 14 sliced ancient Chinese porcelain samples are studied. Comparing with the TACs of natural quartz and synthetic mullite, the relation between the TACs and the composition of the sample is discussed with reference to the X-ray diffraction (XRD) spectra. It is suggested that in some cases, contribution of the porcelain components other than quartz to the TACs is not negligible.

  5. Thermoluminescence and X-ray diffraction studies on sliced ancient porcelain samples

    Science.gov (United States)

    Leung, P. L.; Yang, B.

    1999-09-01

    The thermal activation characteristics (TACs) of the sensitivity of the '110°C' peak in 14 sliced ancient Chinese porcelain samples are studied. Comparing with the TACs of natural quartz and synthetic mullite, the relation between the TACs and the composition of the sample is discussed with reference to the X-ray diffraction (XRD) spectra. It is suggested that in some cases, contribution of the porcelain components other than quartz to the TACs is not negligible.

  6. Sample preparation for large-scale bioanalytical studies based on liquid chromatographic techniques.

    Science.gov (United States)

    Medvedovici, Andrei; Bacalum, Elena; David, Victor

    2018-01-01

    Quality of the analytical data obtained for large-scale and long term bioanalytical studies based on liquid chromatography depends on a number of experimental factors including the choice of sample preparation method. This review discusses this tedious part of bioanalytical studies, applied to large-scale samples and using liquid chromatography coupled with different detector types as core analytical technique. The main sample preparation methods included in this paper are protein precipitation, liquid-liquid extraction, solid-phase extraction, derivatization and their versions. They are discussed by analytical performances, fields of applications, advantages and disadvantages. The cited literature covers mainly the analytical achievements during the last decade, although several previous papers became more valuable in time and they are included in this review. Copyright © 2017 John Wiley & Sons, Ltd.

  7. Enhancing sample preparation capabilities for accelerator mass spectrometry radiocarbon and radiocalcium studies

    International Nuclear Information System (INIS)

    Taylor, R.E.

    1991-01-01

    With support provided by the LLNL Accelerator Mass Spectrometry Laboratory, the UCR Radiocarbon Laboratory continued its studies involving sample pretreatment and target preparation for both AMS radiocarbon ( 14 C) and radiocalcium ( 41 Ca) involving applications to archaeologically -- and paleoanthropologically- related samples. With regard to AMS 14 C-related studies, we have extended the development of a series of procedures which have, as their initial goal, the capability to combust several hundred microgram amounts of a chemically-pretreated organic sample and convert the resultant CO 2 to graphitic carbon which will consistently yield relatively high 13 C - ion currents and blanks which will yield, on a consistent basis, 14 C count rates at or below 0.20% modern, giving an 2 sigma age limit of >50,000 yr BP

  8. Astronauts Armstrong and Aldrin study rock samples during field trip

    Science.gov (United States)

    1969-01-01

    Astronaut Neil Armstrong, commander of the Apollo 11 lunar landing mission, and Astronaut Edwin Aldrin, Lunar module pilot for Apollo 11, study rock samples during a geological field trip to the Quitman Mountains area near the Fort Quitman ruins in far west Texas.

  9. A study on the weather sampling method for probabilistic consequence analysis

    International Nuclear Information System (INIS)

    Oh, Hae Cheol

    1996-02-01

    The main task of probabilistic accident consequence analysis model is to predict the radiological situation and to provide a reliable quantitative data base for making decisions on countermeasures. The magnitude of accident consequence is depended on the characteristic of the accident and the weather coincident. In probabilistic accident consequence analysis, it is necessary to repeat the atmospheric dispersion calculation with several hundreds of weather sequences to predict the full distribution of consequences which may occur following a postulated accident release. It is desirable to select a representative sample of weather sequences from a meteorological record which is typical of the area over which the released radionuclides will disperse and which spans a sufficiently long period. The selection process is done by means of sampling techniques from a full year of hourly weather data characteristic of the plant site. In this study, the proposed Weighted importance sampling method selects proportional to the each bin size to closely approximate the true frequency distribution of weather condition at the site. The Weighted importance sampling method results in substantially less sampling uncertainty than the previous technique. The proposed technique can result in improve confidence in risk estimates

  10. Study of adolescents exposed in utero. Methodological evaluation of the Nagasaki sample

    Energy Technology Data Exchange (ETDEWEB)

    Hrubec, Zdenek, Noble, K.B.; Burrow, G N

    1962-09-12

    Fetal tissues have been shown to be extremely sensitive to ionizing radiation, and therefore a group of children who were exposed in utero are of special interest. When these children entered adolescence, an intensive study was undertaken to determine whether differences not otherwise apparent would be revealed during the stress of this period of rapid growth. The purpose of this report is to describe the sample used to study these adolescent children who were exposed in utero and to provide reference information. The problems of using ex post facto methods as employed in this study have been discussed in detail elsewhere. In summary, the extent to which findings of a retrospective study may be generalized to a larger population can be determined only from a careful and extensive study of the characteristics of the sample and an evaluation of the procedures used in its selection. It is generally recognized that even an extensive methodologic exploration of this kind offers no conclusive proof that a sample is useful for a specific study. In the sample, some variables which may have a considerable effect on the medical data, such as socioeconomic status, have been taken into account only superficially. There is always the possibility that some important, completely unsuspected variables may produce spurious associations. However there is an almost infinite number of such factors which might conceivably affect the data. Vast research resources could be committed to a methodologic evaluation without fulfilling the basic purpose of the study. An approach must be devised which is judged methodologically adequate but which will not tax the research resource to the detriment of the basic objectives. It is hoped that this report will satisfy the requirements of this compromise. 30 references, 36 tables.

  11. Study of polyconsumption in a 2005 Bogota driver's sample

    Directory of Open Access Journals (Sweden)

    Óscar Armando Sánchez Cardozo

    2007-01-01

    Full Text Available Background. We do not know of studies in our city that indicate the degree of poly illicit drugs consumption in motor vehicles drivers. Use of illicit drugs can explain in some cases the lack of agreement among measurement of breath alcohol test, blood alcohol concentration, and clinical examination in motor vehicles drivers when they are suspects of alcoholic intoxication. In this report we want to center on showing the use of illicit drugs and their clinical manifestations in a sample of motor vehicles drivers. Objective. To determine the consumption of illicit drugs in a sample of motor vehicle drivers, when they are suspects of alcoholic intoxication. Materials and methods. We took a representative sample within 68 motor vehicle drivers. We performed on all of them clinical examination, measurement of breath alcohol tests and blood alcohol concentration. Also we collected urine samples. Five (5 substances were investigated according to their high prevalence in our population: opiate, marijuana, cocaine, amphetamines and benzodiazepines. Results.There were seven cases of illicit drug consumption: the most frequent combination found was (5-7 cases alcohol plus marijuana. In three cases we found consumption of three illicit drugs: 2 cases have alcohol, marijuana and cocaine. Only one case of alcohol, benzodiazepine and cocaine. Conclusions. In the sample analyzed the use of illicit drugs was 10.14 %. The most common form of use is a depressor with a stimulant. If it is recent, it diminishes the neurological manifestations, but it does not affect the presentation nor the severity of the rotacional nystagmus. The alterations of the superior mental functions were seen to be associated with alcohol consumption plus benzodiazepines. Combination of two depressors increases the motor alterations and seems that it alters the superior mental functions. In the negative clinical examinations it was concluded that there was no alcohol intoxication and no

  12. Electron spin resonance of particulate soot samples from automobiles to help environmental studies

    International Nuclear Information System (INIS)

    Yamanaka, C.; Matsuda, T.; Ikeya, M.

    2005-01-01

    The application of electron spin resonance (ESR) was studied for diesel soot samples and suspended particulate matter (SPM) from automobile engines. Soot samples or diesel exhaust particles (DEP) were recovered at various points: in the exhaust pipe of a diesel engine, at the dust sampler of a highway tunnel (standard DEP), on the soundproofing wall alongside a heavy traffic road, and on the filters of a dust sampler for SPM. The diesel soot samples apparently showed two ESR spectra: one was a broad spectrum at g=2.1 with a line width of ca. 80-120mT and the other was a sharp signal of a carbon radical at g=2.003 with a line width of 0.4mT. Annealing experiments with a DEP sample at 250 deg. C revealed drastic enhancement of the sharp ESR signal, which suggested a thermal process of carbonization of remnant organics. An oximetric study by ESR showed an enhancement of the broad signal in the diesel soot sample as well as in the sharp ESR signal. Therefore, the main part of the broad ESR signal would be attributed to carbon radicals, which form a different configuration, probably closely interacting aggregates. Enhancement of the sharp ESR signal was not observed in the standard DEP sample under vacuum condition, which suggested less adsorption sites on the surface of DEP samples

  13. The impact of sample size and marker selection on the study of haplotype structures

    Directory of Open Access Journals (Sweden)

    Sun Xiao

    2004-03-01

    Full Text Available Abstract Several studies of haplotype structures in the human genome in various populations have found that the human chromosomes are structured such that each chromosome can be divided into many blocks, within which there is limited haplotype diversity. In addition, only a few genetic markers in a putative block are needed to capture most of the diversity within a block. There has been no systematic empirical study of the effects of sample size and marker set on the identified block structures and representative marker sets, however. The purpose of this study was to conduct a detailed empirical study to examine such impacts. Towards this goal, we have analysed three representative autosomal regions from a large genome-wide study of haplotypes with samples consisting of African-Americans and samples consisting of Japanese and Chinese individuals. For both populations, we have found that the sample size and marker set have significant impact on the number of blocks and the total number of representative markers identified. The marker set in particular has very strong impacts, and our results indicate that the marker density in the original datasets may not be adequate to allow a meaningful characterisation of haplotype structures. In general, we conclude that we need a relatively large sample size and a very dense marker panel in the study of haplotype structures in human populations.

  14. Using Environmental Variables for Studying of the Quality of Sampling in Soil Mapping

    Directory of Open Access Journals (Sweden)

    A. Jafari

    2016-02-01

    Full Text Available Introduction: Methods of soil survey are generally empirical and based on the mental development of the surveyor, correlating soil with underlying geology, landforms, vegetation and air-photo interpretation. Since there are no statistical criteria for traditional soil sampling; this may lead to bias in the areas being sampled. In digital soil mapping, soil samples may be used to elaborate quantitative relationships or models between soil attributes and soil covariates. Because the relationships are based on the soil observations, the quality of the resulting soil map depends also on the soil observation quality. An appropriate sampling design for digital soil mapping depends on how much data is available and where the data is located. Some statistical methods have been developed for optimizing data sampling for soil surveys. Some of these methods deal with the use of ancillary information. The purpose of this study was to evaluate the quality of sampling of existing data. Materials and Methods: The study area is located in the central basin of the Iranian plateau (Figure 1. The geologic infrastructure of the area is mainly Cretaceous limestone, Mesozoic shale and sandstone. Air photo interpretation (API was used to differentiate geomorphic patterns based on their formation processes, general structure and morphometry. The patterns were differentiated through a nested geomorphic hierarchy (Fig. 2. A four-level geomorphic hierarchy is used to breakdown the complexity of different landscapes of the study area. In the lower level of the hierarchy, the geomorphic surfaces, which were formed by a unique process during a specific geologic time, were defined. A stratified sampling scheme was designed based on geomorphic mapping. In the stratified simple random sampling, the area was divided into sub-areas referred to as strata based on geomorphic surfaces, and within each stratum, sampling locations were randomly selected (Figure 2. This resulted in 191

  15. Experimental Study and Mathematical Modeling of Asphaltene Deposition Mechanism in Core Samples

    Directory of Open Access Journals (Sweden)

    Jafari Behbahani T.

    2015-11-01

    Full Text Available In this work, experimental studies were conducted to determine the effect of asphaltene deposition on the permeability reduction and porosity reduction of carbonate, sandstone and dolomite rock samples using an Iranian bottom hole live oil sample which is close to reservoir conditions, whereas in the majority of previous work, a mixture of recombined oil (a mixture of dead oil and associated gas was injected into a core sample which is far from reservoir conditions. The effect of the oil injection rate on asphaltene deposition and permeability reduction was studied. The experimental results showed that an increase in the oil injection flow rate can result in an increase in asphaltene deposition and permeability reduction. Also, it can be observed that at lower injection flow rates, a monotonic decrease in permeability of the rock samples can be attained upon increasing the injection flow rate, while at higher injection rates, after a decrease in rock permeability, an increasing trend is observed before a steady-state condition can be reached. The experimental results also showed that the rock type can affect the amount of asphaltene deposition, and the asphaltene deposition has different mechanisms in sandstone and carbonate core samples. It can be seen that the adsorption and plugging mechanisms have a more important role in asphaltene deposition in carbonate core samples than sandstone core samples. From the results, it can be observed that the pore volumes of the injected crude oil are higher for sandstone cores compared with the carbonate cores. Also, it can be inferred that three depositional types may take place during the crude oil injection, i.e., continuous deposition for low-permeability cores, slow, steady plugging for high-permeability cores and steady deposition for medium-permeability cores. It can be seen from the experimental results that damage to the core samples was found to increase when the production pressures were

  16. Study population, questionnaire, data management and sample description

    Directory of Open Access Journals (Sweden)

    Chiara de Waure

    2015-06-01

    Full Text Available INTRODUCTION: This article describes methodological issues of the "Sportello Salute Giovani" project ("Youth Health Information Desk", a multicenter study aimed at assessing the health status and attitudes and behaviours of university students in Italy. MATERIALS AND METHODS: The questionnaire used to carry out the study was adapted from the Italian health behaviours in school-aged children (HBSC project and consisted of 93 items addressing: demographics; nutritional habits and status; physical activity; lifestyles; reproductive and preconception health; health and satisfaction of life; attitudes and behaviours toward academic study and new technologies. The questionnaire was administered to a pool of 12 000 students from 18 to 30 years of age who voluntary decided to participate during classes held at different Italian faculties or at the three "Sportello Salute Giovani" centers which were established in the three sites of the Università Cattolica del Sacro Cuore (Catholic University of the Sacred Heart of Rome. RESULTS: The final study sample was composed by 8516 university students. The mean age of responders was 22.2 (Standard Deviation 2.0 and 5702 (67.0% were females. According to the distribution in age classes, 3601 (43.3% belonged to the 18-21 one, 3796 (44.5% to the 22-24 class and 1019 (12.2% to the 25-30 class. With respect to socio-economic status, data were available for 8410 responders and showed that 50.3% of students belonged to the middle class. DISCUSSION: The project took into consideration a large number of individuals from different regions of the country and therefore may be considered representative of the general population of Italian university students. Furthermore, it is the first to address, at the same time, several issues, in particular attitudes and behaviours toward health, in Italian university students. CONCLUSION: The analysis of data from such a large sample of university students sets the basis for

  17. Breeding snow: an instrumented sample holder for simultaneous tomographic and thermal studies

    International Nuclear Information System (INIS)

    Pinzer, B; Schneebeli, M

    2009-01-01

    To study the recrystallization processes during temperature gradient metamorphism of snow, we developed a sample holder that allows applying well-defined and stable thermal gradients to a snow sample while it is scanned in an x-ray micro-tomograph. To this end, both the thermal insulation of the sample as well as image contrast and resolution of the tomography had to be optimized. We solved this conflict by using thin aluminum cylinders in combination with highly insulating foam. This design is light, does not corrupt image quality and provides very good thermal decoupling from the environment. The sample holder was instrumented to measure the effective conductivity of the snow sample and calibrated using five materials of known conductivity. Finite element simulations were consistent with the calibration measurements and gave insight into the internal temperature and heat flux fields. With this setup, geometric and thermal evolution of snow under realistic thermal boundary conditions like alternating temperature gradients can be measured

  18. Abortion experiences among Zanzibari women: a chain-referral sampling study.

    Science.gov (United States)

    Norris, Alison; Harrington, Bryna J; Grossman, Daniel; Hemed, Maryam; Hindin, Michelle J

    2016-03-11

    In Zanzibar, a semi-autonomous region of Tanzania, induced abortion is illegal but common, and fewer than 12% of married reproductive-aged women use modern contraception. As part of a multi-method study about contraception and consequences of unwanted pregnancies, the objective of this study was to understand the experiences of Zanzibari women who terminated pregnancies. The cross-sectional study was set in Zanzibar, Tanzania. Participants were a community-based sample of women who had terminated pregnancies. We carried out semi-structured interviews with 45 women recruited via chain-referral sampling. We report the characteristics of women who have had abortions, the reasons they had abortions, and the methods used to terminate their pregnancies. Women in Zanzibar terminate pregnancies that are unwanted for a range of reasons, at various points in their reproductive lives, and using multiple methods. While clinical methods were most effective, nearly half of our participants successfully terminated a pregnancy using non-clinical methods and very few had complications requiring post abortion care (PAC). Even in settings where abortion is illegal, some women experience illegal abortions without adverse health consequences, what we might call 'safer' unsafe abortions; these kinds of abortion experiences can be missed in studies about abortion conducted among women seeking PAC in hospitals.

  19. Sample holder for studying temperature dependent particle guiding

    International Nuclear Information System (INIS)

    Bereczky, R.J.; Toekesi, K.; Kowarik, G.; Aumayr, F.

    2011-01-01

    Complete text of publication follows. The so called guiding effect is a complex process involving the interplay of a large number of charged particles with a solid. Although many research groups joined this field and carried out various experiments with insulator capillaries many details of the interactions are still unknown. We investigated the temperature dependence of the guiding since it opens new possibilities both for a fundamental understanding of the guiding phenomenon and for applications. For the temperature dependent guiding experiments a completely new heatable sample holder was designed. We developed and built such a heatable sample holder to make accurate and reproducible studies of the temperature dependence of the ion guiding effect possible. The target holder (for an exploded view see Fig. 1) consists of two main parts, the front and the back plates. The two plates of the sample holder, which function as an oven, are made of copper. These parts surround the capillary in order to guarantee a uniform temperature along the whole tube. The temperature of the copper parts is monitored by a K-Type thermocouple. Stainless steel coaxial heaters surrounding the oven are used for heating. The heating power up to a few watts is regulated by a PID controller. Cooling of the capillary is achieved by a copper feed-through connected to a liquid nitrogen bath outside the UHV chamber. This solution allows us to change the temperature of the sample from -30 deg C up to 90 deg C. Our experiments with this newly developed temperature regulated capillary holder show that the glass temperature (i.e. conductivity) can be used to control the guiding properties of the glass capillary and adjust the conditions from guiding at room temperature to simple geometrical transmission at elevated temperatures. This holds the promise to investigate the effect of conductivity on particle transport (build-up and removal of charge patches) through capillaries in more details

  20. A study on aluminum determination in environmental samples by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Noyori, Amanda

    2017-01-01

    Aluminum determinations are of great interest since this element is toxic to humans and it is widely distributed in the environment. Besides, the determinations of this element by conventional analytical methods present difficulties due to sample contamination during the analyses. Neutron activation analysis (NAA) for Al determination presents advantages of fast analyses and of high sensitivity. However, NAA of Al does present problems of P and Si nuclear reaction interferences. Aluminum is determined by measuring 28 Al, formed in the reaction 27 Al (n, γ) 28 Al, the same radioisotope formed in reactions 31 P (n, α) 28 Al and 28 Si (n, p) 28 Al. The purpose of this study was to determine Al in environmental samples by NAA correcting these interferences using correction factors, and determining P and Si concentrations in the samples. In this study, certified reference materials and biomonitor samples (tree barks and lichen) were analyzed. Experimental procedure consisted of irradiating an aliquot of the sample at the IEA-R1 nuclear research reactor together with Al standard, followed by gamma ray spectrometry. Phosphorus was determined by measuring beta radiation of 32 P using a Geiger-Müller counter. Silicon was determined by epithermal neutron activation analysis and measuring 29 Al formed in the reaction 29 Si (n, p) 29 Al. Results obtained in the determination of Al, P and Si in the certified reference materials showed good precision and accuracy with |Z-score| ≤ 2. Aluminum results in the biomonitor samples varied from to 253 to 15783 μg g -1 . In the case of P its concentrations varied from 283 to 1946 μg g -1 . Silicon determinations in biomonitors varied from 0.11 to 7.8 %. The interference contribution rates in the analyses of the biomonitor samples were of the order of 2.0 % and this contribution depends on the relation between concentrations of interfering elements and of Al in the sample. Detection limit values of Al in the biomonitor analyses

  1. Laboratory Studies on Surface Sampling of Bacillus anthracis Contamination: Summary, Gaps, and Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Hu, Rebecca

    2011-11-28

    This report summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the (1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and (2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed and recommendations are given for future studies.

  2. Study on infrasonic characteristics of coal samples in failure process under uniaxial loading

    Directory of Open Access Journals (Sweden)

    Bing Jia

    Full Text Available To study the precursory failure infrasonic characteristics of coal samples, coal rock stress loading system and infrasonic wave acquisition system were adopted, and infrasonic tests in uniaxial loading process were made for the coal samples in the studied area. Wavelet filtering, fast Fourier transform, and relative infrasonic energy methods were used to analyze the characteristics of the infrasonic waves in the loading process, including time domain characteristics, and relative energy. The analysis results demonstrated that the frequencies of the infrasonic signals in the loading process mainly distribute within 5–10 Hz, which are significantly different from noise signals. The changes of the infrasonic signals show clear periodic characters in time domain. Meanwhile, the relative energy changes of the infrasonic wave also show periodic characters, which are divided into two stages by the yield limit of coal samples, and are clear and easy to be recognized, so that they can be used as the precursory characteristics for recognizing coal sample failures. Moreover, the infrasonic waves generated by coal samples have low frequency and low attenuation, which can be collected without coupling and transmitted in long distance. This study provides an important support for the further in-situ prediction of coal rock failures. Keywords: Infrasound, Relative energy, Time-frequency analysis, Failure prediction, Identification feature

  3. Amostragem de solo para estudos de fertilidade Sampling soils for fertility studies

    Directory of Open Access Journals (Sweden)

    R. A. Catani

    1955-01-01

    Full Text Available O presente trabalho foi realizado com a finalidade de estabelecer um sistema e técnica mais adequados de se coletar amostras de terra, para fins de estudo de fertilidade. Foram escolhidas duas áreas de solos diferentes. Uma delas com seis hectares, situada na Estação Experimental de Ribeirão Prêto, em solo tipo terra roxa legítima ; a outra com quatro hectares e localizada na Fazenda Santa Maria, em Pindorama, em solo do tipo arenito Bauru. A retirada das amostras de cada área foi feita com tubos especialmente construídos para esse fim e obedeceu ao seguinte critério: 1 30 amostras simples, cobrindo tôda a área ; 2 10 amostras compostas, formadas de cinco amostras simples, cobrindo tôda a área. 3 5 amostras compostas, formadas de 20 amostras simples, cobrindo tôda a área. Nessas amostras foram determinados : pH, carbono total, potássio "trocável" e cálcio "trocável". Diante dos dados obtidos e levando-se em conta o trabalho exigido no laboratório, aconselha-se a retirada de três amostras compostas formadas de 20 simples cada uma, em glebas uniformes, de cinco hectares aproximadamente.The following methods of collecting soil samples for fertility studies were compared : 1 thirty individual samples covering the whole area ; 2 ten composite samples, each consisting of five individual samples, covering the whole area ; 3 five composite samples, each consisting of 20 individual samples, covering the whole area. The three types of samples were collected in each of two plots : 1 a six-hectare plot in the Estação Experimental de Ribeirão Prêto, representing the "terra roxa" soil; 2 a four-hectare plot in the Santa Maria Farm, Pindorama, where the soil is of the "arenito de Bauru" type. The pH, total carbon, and exchangeable potassium and calcium were determined in the samples. Based on data obtained in the present investigation and considering the amount of work involved in the routine laboratory tests, it is suggested that

  4. DNA methylation analysis from saliva samples for epidemiological studies.

    Science.gov (United States)

    Nishitani, Shota; Parets, Sasha E; Haas, Brian W; Smith, Alicia K

    2018-06-18

    Saliva is a non-invasive, easily accessible tissue, which is regularly collected in large epidemiological studies to examine genetic questions. Recently, it is becoming more common to use saliva to assess DNA methylation. However, DNA extracted from saliva is a mixture of both bacterial and human DNA derived from epithelial and immune cells in the mouth. Thus, there are unique challenges to using salivary DNA in methylation studies that can influence data quality. This study assesses: (1) quantification of human DNA after extraction; (2) delineation of human and bacterial DNA; (3) bisulfite conversion (BSC); (4) quantification of BSC DNA; (5) PCR amplification of BSC DNA from saliva and; (6) quantitation of DNA methylation with a targeted assay. The framework proposed will allow saliva samples to be more widely used in targeted epigenetic studies.

  5. Study on auto-plating process time versus recovery for polonium, Po-210 in environmental sample

    International Nuclear Information System (INIS)

    Jalal Sharib; Zaharudin Ahmad; Abdul Kadir Ishak; Norfaizal Mohamed; Ahmad Sanadi Abu Bakar; Yii Mei Wo; Kamarozaman Ishak; Siti Aminah Yusoff

    2008-08-01

    This study was carried out to evaluate time effectiveness and recovery 16 samples of 4 Kuala Muda stations during auto-plating process procedures for determination Polonium, Po 210 activity concentration in environmental sample. The study was performed using Kuala Muda sediment as sample in the same methodology. The auto-plating process runs for 4, 12, 24 and 30 hours on a silver disc for 4 samples each station, and then counted for one (1) day using an alpha spectrometry counting system. The objectives for this study is to justify on time duration for auto-plating process effecting a chemical yield of Po-209.The results showed recovery are increasing versus time and constantly at 24 hour auto-plating. Its mean, 24 hour is an optimum time for auto-plating process for determination of Polonium, Po 210 activity concentration in environmental sample. (Author)

  6. Defining And Characterizing Sample Representativeness For DWPF Melter Feed Samples

    Energy Technology Data Exchange (ETDEWEB)

    Shine, E. P.; Poirier, M. R.

    2013-10-29

    Representative sampling is important throughout the Defense Waste Processing Facility (DWPF) process, and the demonstrated success of the DWPF process to achieve glass product quality over the past two decades is a direct result of the quality of information obtained from the process. The objective of this report was to present sampling methods that the Savannah River Site (SRS) used to qualify waste being dispositioned at the DWPF. The goal was to emphasize the methodology, not a list of outcomes from those studies. This methodology includes proven methods for taking representative samples, the use of controlled analytical methods, and data interpretation and reporting that considers the uncertainty of all error sources. Numerous sampling studies were conducted during the development of the DWPF process and still continue to be performed in order to evaluate options for process improvement. Study designs were based on use of statistical tools applicable to the determination of uncertainties associated with the data needs. Successful designs are apt to be repeated, so this report chose only to include prototypic case studies that typify the characteristics of frequently used designs. Case studies have been presented for studying in-tank homogeneity, evaluating the suitability of sampler systems, determining factors that affect mixing and sampling, comparing the final waste glass product chemical composition and durability to that of the glass pour stream sample and other samples from process vessels, and assessing the uniformity of the chemical composition in the waste glass product. Many of these studies efficiently addressed more than one of these areas of concern associated with demonstrating sample representativeness and provide examples of statistical tools in use for DWPF. The time when many of these designs were implemented was in an age when the sampling ideas of Pierre Gy were not as widespread as they are today. Nonetheless, the engineers and

  7. Defining And Characterizing Sample Representativeness For DWPF Melter Feed Samples

    International Nuclear Information System (INIS)

    Shine, E. P.; Poirier, M. R.

    2013-01-01

    Representative sampling is important throughout the Defense Waste Processing Facility (DWPF) process, and the demonstrated success of the DWPF process to achieve glass product quality over the past two decades is a direct result of the quality of information obtained from the process. The objective of this report was to present sampling methods that the Savannah River Site (SRS) used to qualify waste being dispositioned at the DWPF. The goal was to emphasize the methodology, not a list of outcomes from those studies. This methodology includes proven methods for taking representative samples, the use of controlled analytical methods, and data interpretation and reporting that considers the uncertainty of all error sources. Numerous sampling studies were conducted during the development of the DWPF process and still continue to be performed in order to evaluate options for process improvement. Study designs were based on use of statistical tools applicable to the determination of uncertainties associated with the data needs. Successful designs are apt to be repeated, so this report chose only to include prototypic case studies that typify the characteristics of frequently used designs. Case studies have been presented for studying in-tank homogeneity, evaluating the suitability of sampler systems, determining factors that affect mixing and sampling, comparing the final waste glass product chemical composition and durability to that of the glass pour stream sample and other samples from process vessels, and assessing the uniformity of the chemical composition in the waste glass product. Many of these studies efficiently addressed more than one of these areas of concern associated with demonstrating sample representativeness and provide examples of statistical tools in use for DWPF. The time when many of these designs were implemented was in an age when the sampling ideas of Pierre Gy were not as widespread as they are today. Nonetheless, the engineers and

  8. Study of Zn/Cu ratio and oligoelements in serum samples for cancer diagnosis

    International Nuclear Information System (INIS)

    Lue-Meru, M. P.; Jimenez, E.; Hernandez, E.; Rojas, A.; Greaves, E.

    2000-01-01

    The aim of this work was to study methods for cancer diagnosis based on trace element determination in serum blood samples. TXRF technique was selected for the analysis, due to its simultaneous and multi-elemental character, the very small amount of sample required and the high sensitivity. For the study, blood samples were collected from normal individuals (Blood donors and students), classified by age and sex in order to obtain reference normal values for the elements Zn, Cu, Fe, Mn, Se, and additionally, Ca and K. Samples from cancer patients before treatment and under treatment were collected at the oncological Service (BADAN-Lara), and were also classified by age and sex. The TXRF procedure used was developed in a previous work and involves the direct analysis and the use of Compton peak as Internal Standard. All the samples were analyzed by the routine clinical test (blood chemistry). Elemental concentrations and clinical data were processed with the statistical package Minitab-Windows, in order to establish the respective correlation. Concerning to elemental concentrations, significant differences were found in Zn/Cu ratio between normal individuals group and the cancer patients group. (author)

  9. THE STUDY OF HEAVY METAL FROM ENVIRONMENTAL SAMPLES BY ATOMIC TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Ion V. POPESCU

    2011-05-01

    Full Text Available Using the Atomic Absorption Spectrometry (AAS and Energy Dispersive X-ray spectrometry (EDXRF techniques we analyzed the contents of heavy metals ( Cd, Cr, Ni, Pb, Ti, Sr, Co, Bi from eight wild mushrooms and soil substrate samples (48 samples of eight fungal species and 32 underlying soil samples, collected from ten forest sites of Dambovița County Romania. It was determined that the elements, especially heavy metals, in soil were characteristic of the acidic soils of the Romanian forest lands and are influenced by industrial pollution. Analytical possibilities of AAS and EDXRF analytical techniques have been compared and the heavy metal transfer from substrate to mushrooms has been studied. The coefficient of accumulation of essential and heavy metals has been calculated as well. Heavy metal contents of all analyzed mushrooms were generally higher than previously reported in literature.

  10. Study on natural radioactive elements in soil and rock samples around Mandya district, India

    International Nuclear Information System (INIS)

    Shivakumara, B.C.; Paramesh, L.; Shashikumar, T.S.; Chandrashekara, M.S.

    2012-01-01

    The soil is a complex mixture of different compounds and rocks. In the natural environment, it is an important source of exposure to radiation due to naturally occurring, gamma emitting radionuclides which include 226 Ra, 232 Th and 40 K present in the soil. The study of distribution of these radionuclides in soil and rock is of great importance for radiation protection and measurements. The activity concentrations of 226 Ra, 232 Th, and 40 K in soil and rock samples collected in Mandya District, Karnataka state, India have been measured by gamma ray spectrometry. The average activity concentrations of 226 Ra, 232 Th, and 40 K (Bq/kg) are found to be 40.2, 62.3, and 317.5 Bq/kg, respectively, in soil samples and 30.5, 34.4, and 700.2 Bq/kg, respectively, in rock samples. The concentrations of radionuclides in soil samples are found to higher than in rock samples. The concentrations of radionuclides in soil and rock samples in the study area are slightly higher than Indian average and world average values. (author)

  11. Study of Organochlorinated Pesticide Residues and Polychlorinated Biphenyls in Soil Samples

    Directory of Open Access Journals (Sweden)

    MSc. Vlora Gashi

    2013-12-01

    Full Text Available This paper presents and discusses the data obtained for organochlorinated pesticides and their residues in the soil samples of agricultural areas. Soil contamination is one of most important factors influencing the quality of agricultural products. Usage of heavy farm equipment, the land drainage, an exces­sive application of agrochemicals, emissions originating from mining, metallurgical, and chemical and coal power plants and transport, all generate a number of undesired substances (nitric and sulphur oxides, PAHs, heavy metals, pesticides, which after deposition in soil may influence crop quality. Thus, input of these contaminants into the environment should be carefully monitored. Levels of organochlorinated pesticides contamination were evaluated in agriculture areas that are in use. 10 soil samples were taken in agricultural areas  Plane of  Dugagjini , Kosovo. Representa­tive soil samples were collected from 0-30 cm top layer of the soil. In the analytical method we combined ultrasonic bath extraction and a Florisil column for samples clean-up. The analysis of the organochlorinated pesticides in soil samples was performed by gas chromatography technique using electron capture detector (GC/ECD. Optima-5 (low/mid polarity, 5% phenyl methyl siloxane 60 m x 0.33 mm x 0.25μm film capillary column was used for isolation and determination of organochlorinated pesticides. Low concentrations of organochlorinated pesticide and their metabolites were found in the studied samples. The presence of organochlorinated pesticides and their residues is probably resulting of their previous uses for agricultural purposes.

  12. Pierre Gy's sampling theory and sampling practice heterogeneity, sampling correctness, and statistical process control

    CERN Document Server

    Pitard, Francis F

    1993-01-01

    Pierre Gy's Sampling Theory and Sampling Practice, Second Edition is a concise, step-by-step guide for process variability management and methods. Updated and expanded, this new edition provides a comprehensive study of heterogeneity, covering the basic principles of sampling theory and its various applications. It presents many practical examples to allow readers to select appropriate sampling protocols and assess the validity of sampling protocols from others. The variability of dynamic process streams using variography is discussed to help bridge sampling theory with statistical process control. Many descriptions of good sampling devices, as well as descriptions of poor ones, are featured to educate readers on what to look for when purchasing sampling systems. The book uses its accessible, tutorial style to focus on professional selection and use of methods. The book will be a valuable guide for mineral processing engineers; metallurgists; geologists; miners; chemists; environmental scientists; and practit...

  13. Field-based random sampling without a sampling frame: control selection for a case-control study in rural Africa.

    Science.gov (United States)

    Crampin, A C; Mwinuka, V; Malema, S S; Glynn, J R; Fine, P E

    2001-01-01

    Selection bias, particularly of controls, is common in case-control studies and may materially affect the results. Methods of control selection should be tailored both for the risk factors and disease under investigation and for the population being studied. We present here a control selection method devised for a case-control study of tuberculosis in rural Africa (Karonga, northern Malawi) that selects an age/sex frequency-matched random sample of the population, with a geographical distribution in proportion to the population density. We also present an audit of the selection process, and discuss the potential of this method in other settings.

  14. Study on sampling of continuous linear system based on generalized Fourier transform

    Science.gov (United States)

    Li, Huiguang

    2003-09-01

    In the research of signal and system, the signal's spectrum and the system's frequency characteristic can be discussed through Fourier Transform (FT) and Laplace Transform (LT). However, some singular signals such as impulse function and signum signal don't satisfy Riemann integration and Lebesgue integration. They are called generalized functions in Maths. This paper will introduce a new definition -- Generalized Fourier Transform (GFT) and will discuss generalized function, Fourier Transform and Laplace Transform under a unified frame. When the continuous linear system is sampled, this paper will propose a new method to judge whether the spectrum will overlap after generalized Fourier transform (GFT). Causal and non-causal systems are studied, and sampling method to maintain system's dynamic performance is presented. The results can be used on ordinary sampling and non-Nyquist sampling. The results also have practical meaning on research of "discretization of continuous linear system" and "non-Nyquist sampling of signal and system." Particularly, condition for ensuring controllability and observability of MIMO continuous systems in references 13 and 14 is just an applicable example of this paper.

  15. Numerical study of the lateral resolution in electrostatic force microscopy for dielectric samples

    International Nuclear Information System (INIS)

    Riedel, C; AlegrIa, A; Colmenero, J; Schwartz, G A; Saenz, J J

    2011-01-01

    We present a study of the lateral resolution in electrostatic force microscopy for dielectric samples in both force and gradient modes. Whereas previous studies have reported expressions for metallic surfaces having potential heterogeneities (Kelvin probe force microscopy), in this work we take into account the presence of a dielectric medium. We introduce a definition of the lateral resolution based on the force due to a test particle being either a point charge or a polarizable particle on the dielectric surface. The behaviour has been studied over a wide range of typical experimental parameters: tip-sample distance (1-20) nm, sample thickness (0-5) μm and dielectric constant (1-20), using the numerical simulation of the equivalent charge method. For potential heterogeneities on metallic surfaces expressions are in agreement with the bibliography. The lateral resolution of samples having a dielectric constant of more than 10 tends to metallic behaviour. We found a characteristic thickness of 100 nm, above which the lateral resolution measured on the dielectric surface is close to that of an infinite medium. As previously reported, the lateral resolution is better in the gradient mode than in the force mode. Finally, we showed that for the same experimental conditions, the lateral resolution is better for a polarizable particle than for a charge, i.e. dielectric heterogeneities should always look 'sharper' (better resolved) than inhomogeneous charge distributions. This fact should be taken into account when interpreting images of heterogeneous samples.

  16. Numerical study of the lateral resolution in electrostatic force microscopy for dielectric samples

    Energy Technology Data Exchange (ETDEWEB)

    Riedel, C; AlegrIa, A; Colmenero, J [Departamento de Fisica de Materiales UPV/EHU, Facultad de Quimica, Apartado 1072, 20080 San Sebastian (Spain); Schwartz, G A [Centro de Fisica de Materiales CSIC-UPV/EHU, Paseo Manuel de Lardizabal 5, 20018 San Sebastian (Spain); Saenz, J J, E-mail: riedel@ies.univ-montp2.fr [Donostia International Physics Center, Paseo Manuel de Lardizabal 4, 20018 San Sebastian (Spain)

    2011-07-15

    We present a study of the lateral resolution in electrostatic force microscopy for dielectric samples in both force and gradient modes. Whereas previous studies have reported expressions for metallic surfaces having potential heterogeneities (Kelvin probe force microscopy), in this work we take into account the presence of a dielectric medium. We introduce a definition of the lateral resolution based on the force due to a test particle being either a point charge or a polarizable particle on the dielectric surface. The behaviour has been studied over a wide range of typical experimental parameters: tip-sample distance (1-20) nm, sample thickness (0-5) {mu}m and dielectric constant (1-20), using the numerical simulation of the equivalent charge method. For potential heterogeneities on metallic surfaces expressions are in agreement with the bibliography. The lateral resolution of samples having a dielectric constant of more than 10 tends to metallic behaviour. We found a characteristic thickness of 100 nm, above which the lateral resolution measured on the dielectric surface is close to that of an infinite medium. As previously reported, the lateral resolution is better in the gradient mode than in the force mode. Finally, we showed that for the same experimental conditions, the lateral resolution is better for a polarizable particle than for a charge, i.e. dielectric heterogeneities should always look 'sharper' (better resolved) than inhomogeneous charge distributions. This fact should be taken into account when interpreting images of heterogeneous samples.

  17. Evaluation of Skin Surface as an Alternative Source of Reference DNA Samples: A Pilot Study.

    Science.gov (United States)

    Albujja, Mohammed H; Bin Dukhyil, Abdul Aziz; Chaudhary, Abdul Rauf; Kassab, Ahmed Ch; Refaat, Ahmed M; Babu, Saranya Ramesh; Okla, Mohammad K; Kumar, Sachil

    2018-01-01

    An acceptable area for collecting DNA reference sample is a part of the forensic DNA analysis development. The aim of this study was to evaluate skin surface cells (SSC) as an alternate source of reference DNA sample. From each volunteer (n = 10), six samples from skin surface areas (forearm and fingertips) and two traditional samples (blood and buccal cells) were collected. Genomic DNA was extracted and quantified then genotyped using standard techniques. The highest DNA concentration of SSC samples was collected using the tape/forearm method of collection (2.1 ng/μL). Cotton swabs moistened with ethanol yielded higher quantities of DNA than swabs moistened with salicylic acid, and it gave the highest percentage of full STR profiles (97%). This study supports the use of SSC as a noninvasive sampling technique and as a extremely useful source of DNA reference samples among certain cultures where the use of buccal swabs can be considered socially unacceptable. © 2017 American Academy of Forensic Sciences.

  18. The study of penetration of energetic ions in botanic samples with transmission measurements

    International Nuclear Information System (INIS)

    Wang, Y.G.; Chen, Q.Z.; Xue, J.M.; Du, G.H.; Qin, H.L; Zhang, W.M.; Yan, S.; Zhao, W.J.

    2006-01-01

    Botanic samples (onion endocuticles, kidney bean slices) were exposed to energetic ions. By recording transmission spectra, we studied the energy loss in such samples. Individual protrusion-like damage produced in highly oriented pyrolytic graphite (HOPG) substrate allowed us to analyze the mass density of the samples by scanning tunneling microscope (STM). The experimental results showed that the botanic sample is inhomogeneous in mass density, some incident ions lose only a small part of their energy after being stopped by a layer of botanic sample. Additionally, about 10 -7 of the incident ions with energy of tens of keV can penetrate through the botanic slice with a thickness of 50 μm. The dynamic change of the transmission spectrum of MeV heavy ions through a layer of botanic slice showed that the penetration ability of the incident ions increases with increasing ion fluence. These experimental results indicate that the inhomogeneousity of mass density of botanic samples and irradiation damage are the main reasons of the ultra-depth penetration of low-energy ions in such kind of botanic samples

  19. Feasibility studies on large sample neutron activation analysis using a low power research reactor

    International Nuclear Information System (INIS)

    Gyampo, O.

    2008-06-01

    Instrumental neutron activation analysis (INAA) using Ghana Research Reactor-1 (GHARR-1) can be directly applied to samples with masses in grams. Samples weights were in the range of 0.5g to 5g. Therefore, the representativity of the sample is improved as well as sensitivity. Irradiation of samples was done using a low power research reactor. The correction for the neutron self-shielding within the sample is determined from measurement of the neutron flux depression just outside the sample. Correction for gamma ray self-attenuation in the sample was performed via linear attenuation coefficients derived from transmission measurements. Quantitative and qualitative analysis of data were done using gamma ray spectrometry (HPGe detector). The results of this study on the possibilities of large sample NAA using a miniature neutron source reactor (MNSR) show clearly that the Ghana Research Reactor-1 (GHARR-1) at the National Nuclear Research Institute (NNRI) can be used for sample analyses up to 5 grams (5g) using the pneumatic transfer systems.

  20. Recruiting a representative sample in adherence research-The MALT multisite prospective cohort study experience.

    Science.gov (United States)

    Shemesh, Eyal; Mitchell, Jeffrey; Neighbors, Katie; Feist, Susan; Hawkins, Andre; Brown, Amanda; Wanrong, Yin; Anand, Ravinder; Stuber, Margaret L; Annunziato, Rachel A

    2017-12-01

    Medication adherence is an important determinant of transplant outcomes. Attempts to investigate adherence are frequently undermined by selection bias: It is very hard to recruit and retain non-adherent patients in research efforts. This manuscript presents recruitment strategies and results from the MALT (Medication Adherence in children who had a Liver Transplant) multisite prospective cohort study. MALT sites recruited 400 pediatric liver transplant patients who agreed to be followed for 2 years. The primary purpose was to determine whether a marker of adherence, the Medication Level Variability Index (MLVI), predicts rejection outcomes. The present manuscript describes methods used in MALT to ensure that a representative sample was recruited, and presents detailed recruitment results. MALT sites were able to recruit a nationally representative sample, as determined by a comparison between the MALT cohort and a national sample of transplant recipients. Strategies that helped ensure that the sample was representative included monitoring of the outcome measure in comparison with a national sample, drastically limiting patient burden, and specific recruitment methods. We discuss the importance of a representative sample in adherence research and recommend that future efforts to study adherence pay special attention to sample characteristics. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. [Formal sample size calculation and its limited validity in animal studies of medical basic research].

    Science.gov (United States)

    Mayer, B; Muche, R

    2013-01-01

    Animal studies are highly relevant for basic medical research, although their usage is discussed controversially in public. Thus, an optimal sample size for these projects should be aimed at from a biometrical point of view. Statistical sample size calculation is usually the appropriate methodology in planning medical research projects. However, required information is often not valid or only available during the course of an animal experiment. This article critically discusses the validity of formal sample size calculation for animal studies. Within the discussion, some requirements are formulated to fundamentally regulate the process of sample size determination for animal experiments.

  2. Oppositional Behavior and Anxiety in Boys and Girls: A Cross-Sectional Study in Two Community Samples

    Science.gov (United States)

    Mireault, Gina; Rooney, Siri; Kouwenhoven, Kristen; Hannan, Carolyn

    2008-01-01

    Studies have repeatedly shown that oppositional behavior is linked to anxiety in clinical samples of children. This study explored whether these variables were similarly related in nonclinical samples of elementary and middle school students (N = 302). Despite greater self-reported oppositional behavior among boys in these samples, anxiety…

  3. Isotopic studies of rare gases in terrestrial samples and natural nucleosynthesis

    International Nuclear Information System (INIS)

    1990-07-01

    This project is concerned with research in rare gas mass spectrometry. We read the natural record that isotopes of the rare gases provide. We study fluids using a system (RARGA) that is sometimes deployed in the field. In 1990 there was a strong effort to reduce the backlog of RARGA samples on hand, so that it was a year of intensive data gathering. Samples from five different areas in the western United States and samples from Guatemala and Australia were analyzed. In a collaborative study we also began analyzing noble gases from rocks associated with the fluids. An important objective, continuing in 1991, is to understand better the reasons for somewhat elevated 3 He/ 4 He ratios in regions where there is no contemporary volcanism which could produce the effect by addition of mantle helium. Our helium data have given us and our collaborators some insights, which are to be followed up, into gold mineralization in geothermal regions. Our DOE work in calibrating a sensitive laser microprobe mass spectrometer for noble gases in fluid inclusions continues. Having completed a series of papers on noble gases in diamonds, we next will attempt to make precise isotopic measurements on xenon from mantle sources, in search of evidence for terrestrially elusive 244 Pu decay

  4. Isotopic studies of rare gases in terrestrial samples and natural nucleosynthesis

    International Nuclear Information System (INIS)

    Reynolds, J.H.

    1991-01-01

    This project is concerned with research in rare gas mass spectrometry. We read the natural record that isotopes of the rate gases provide. We study fluids using a system (RARGA) that is sometimes deployed in the field. In 1990 there was a strong effort to reduce the backlog of RARGA samples on hand, so that it was a year of intensive data gathering. Samples from five different areas in the Western United States and samples from Guatemala and Australia were analyzed. In a collaborative study we also began analyzing noble gases from rocks associated with the fluids. An important objective, continuing in 1991, is to understand better the reasons for somewhat elevated 3 He/ 4 He ratios in regions where there is no contemporary volcanism which could produce the effect by addition of mantle helium. Our helium data have given us and our collaborators some insights, which are to be followed up, into gold mineralization in geothermal regions. Our DOE work in calibrating a sensitive laser microprobe mass spectrometer for noble gases in fluid inclusions continues. Having completed a series of papers on noble gases in diamonds, we next will attempt to make precise isotopic measurements on xenon from mantle sources in search of evidence for terrestrially elusive 244 Pu decay. 41 refs., 3 figs

  5. Charged-particle track analysis, thermoluminescence and microcratering studies of lunar samples

    International Nuclear Information System (INIS)

    Durrani, S.A.

    1977-01-01

    Studies of lunar samples (from both Apollo and Luna missions) have been carried out, using track analysis and thermoluminescence (t.l.) techniques, with a view to shedding light on the radiation and temperature histories of the Moon. In addition, microcraters in lunar glasses have been studied in order to elucidate the cosmic-dust impact history of the lunar regolith. In tracks studies, the topics discussed include the stabilizing effect of the thermal annealing of fossil tracks due to the lunar temperature cycle; the 'radiation annealing' of fresh heavy-ion tracks by large doses of protons (to simulate the effect of lunar radiation-damage on track registration); and correction factors for the anisotropic etching of crystals which are required in reconstructing the exposure history of lunar grains. An abundance ratio of ca. (1.1 + 0.3) x 10 -3 has been obtained, by the differential annealing technique, for the nuclei beyond the iron group to those within that group in the cosmic rays incident on the Moon. The natural t.l. of lunar samples has been used to estimate their effective storage temperature and mean depth below the surface. The results of the study of natural and artificially produced microcraters have been studied. (author)

  6. Studies of U in the blood of two population samples

    International Nuclear Information System (INIS)

    Segovia, N.; Olguin, M.E.; Romero, M.

    1986-01-01

    The present work, attempts to establish the statistical distribution of blood uranium in a population of the same community, similar in age and in living patterns. U traces were evaluated by a fission track technique both in whole blood and plasma samples. Dried samples were compressed into pellets and irradiated in a nuclear reactor using the external detector method. For U quantification, standard U samples were used. A comparative sampling of U content in blood samples from a group of radiation exposed workers and another of leukemia patients was also carried out. Results from the sampling groups are reported and discussed. (author)

  7. Optimization of sampling parameters for standardized exhaled breath sampling.

    Science.gov (United States)

    Doran, Sophie; Romano, Andrea; Hanna, George B

    2017-09-05

    The lack of standardization of breath sampling is a major contributing factor to the poor repeatability of results and hence represents a barrier to the adoption of breath tests in clinical practice. On-line and bag breath sampling have advantages but do not suit multicentre clinical studies whereas storage and robust transport are essential for the conduct of wide-scale studies. Several devices have been developed to control sampling parameters and to concentrate volatile organic compounds (VOCs) onto thermal desorption (TD) tubes and subsequently transport those tubes for laboratory analysis. We conducted three experiments to investigate (i) the fraction of breath sampled (whole vs. lower expiratory exhaled breath); (ii) breath sample volume (125, 250, 500 and 1000ml) and (iii) breath sample flow rate (400, 200, 100 and 50 ml/min). The target VOCs were acetone and potential volatile biomarkers for oesophago-gastric cancer belonging to the aldehyde, fatty acids and phenol chemical classes. We also examined the collection execution time and the impact of environmental contamination. The experiments showed that the use of exhaled breath-sampling devices requires the selection of optimum sampling parameters. The increase in sample volume has improved the levels of VOCs detected. However, the influence of the fraction of exhaled breath and the flow rate depends on the target VOCs measured. The concentration of potential volatile biomarkers for oesophago-gastric cancer was not significantly different between the whole and lower airway exhaled breath. While the recovery of phenols and acetone from TD tubes was lower when breath sampling was performed at a higher flow rate, other VOCs were not affected. A dedicated 'clean air supply' overcomes the contamination from ambient air, but the breath collection device itself can be a source of contaminants. In clinical studies using VOCs to diagnose gastro-oesophageal cancer, the optimum parameters are 500mls sample volume

  8. Groundwater-quality data in 12 GAMA study units: Results from the 2006–10 initial sampling period and the 2008–13 trend sampling period, California GAMA Priority Basin Project

    Science.gov (United States)

    Mathany, Timothy M.

    2017-03-09

    The Priority Basin Project (PBP) of the Groundwater Ambient Monitoring and Assessment (GAMA) program was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey in cooperation with the California State Water Resources Control Board. From 2004 through 2012, the GAMA-PBP collected samples and assessed the quality of groundwater resources that supply public drinking water in 35 study units across the State. Selected sites in each study unit were sampled again approximately 3 years after initial sampling as part of an assessment of temporal trends in water quality by the GAMA-PBP. Twelve of the study units, initially sampled during 2006–11 (initial sampling period) and sampled a second time during 2008–13 (trend sampling period) to assess temporal trends, are the subject of this report.The initial sampling was designed to provide a spatially unbiased assessment of the quality of untreated groundwater used for public water supplies in the 12 study units. In these study units, 550 sampling sites were selected by using a spatially distributed, randomized, grid-based method to provide spatially unbiased representation of the areas assessed (grid sites, also called “status sites”). After the initial sampling period, 76 of the previously sampled status sites (approximately 10 percent in each study unit) were randomly selected for trend sampling (“trend sites”). The 12 study units sampled both during the initial sampling and during the trend sampling period were distributed among 6 hydrogeologic provinces: Coastal (Northern and Southern), Transverse Ranges and Selected Peninsular Ranges, Klamath, Modoc Plateau and Cascades, and Sierra Nevada Hydrogeologic Provinces. For the purposes of this trend report, the six hydrogeologic provinces were grouped into two hydrogeologic regions based on location: Coastal and Mountain.The groundwater samples were analyzed for a number of synthetic organic

  9. Evaluating sampling strategy for DNA barcoding study of coastal and inland halo-tolerant Poaceae and Chenopodiaceae: A case study for increased sample size.

    Directory of Open Access Journals (Sweden)

    Peng-Cheng Yao

    Full Text Available Environmental conditions in coastal salt marsh habitats have led to the development of specialist genetic adaptations. We evaluated six DNA barcode loci of the 53 species of Poaceae and 15 species of Chenopodiaceae from China's coastal salt marsh area and inland area. Our results indicate that the optimum DNA barcode was ITS for coastal salt-tolerant Poaceae and matK for the Chenopodiaceae. Sampling strategies for ten common species of Poaceae and Chenopodiaceae were analyzed according to optimum barcode. We found that by increasing the number of samples collected from the coastal salt marsh area on the basis of inland samples, the number of haplotypes of Arundinella hirta, Digitaria ciliaris, Eleusine indica, Imperata cylindrica, Setaria viridis, and Chenopodium glaucum increased, with a principal coordinate plot clearly showing increased distribution points. The results of a Mann-Whitney test showed that for Digitaria ciliaris, Eleusine indica, Imperata cylindrica, and Setaria viridis, the distribution of intraspecific genetic distances was significantly different when samples from the coastal salt marsh area were included (P < 0.01. These results suggest that increasing the sample size in specialist habitats can improve measurements of intraspecific genetic diversity, and will have a positive effect on the application of the DNA barcodes in widely distributed species. The results of random sampling showed that when sample size reached 11 for Chloris virgata, Chenopodium glaucum, and Dysphania ambrosioides, 13 for Setaria viridis, and 15 for Eleusine indica, Imperata cylindrica and Chenopodium album, average intraspecific distance tended to reach stability. These results indicate that the sample size for DNA barcode of globally distributed species should be increased to 11-15.

  10. Salivary gland tumours in a Mexican sample. A retrospective study.

    Science.gov (United States)

    Ledesma-Montes, C; Garces-Ortiz, M

    2002-01-01

    Salivary gland tumours are an important part of the Oral and Maxillofacial Pathology, unfortunately, only few studies on these tumours have been done in Latin-American population. The aim of this study was to compare demographic data on salivary gland tumours in a Mexican sample with those previously published from Latin American and non-Latin American countries. All cases of salivary gland tumours or lesions diagnosed in our service were reviewed. Of the reviewed cases,67 were confirmed as salivary gland tumours. Out of these 64.2% were benign neoplasms, 35.8% were malignant and a slight female predominance (56.7%) was found. The most common location was palate followed by lips and floor of the mouth. Mean age for benign tumours was 40.6 years with female predominance (60.5%). Mean age for malignant tumours was 41 years and female predominance was found again. Palate followed by retromolar area were the usual locations. Pleomorphic adenoma (58.2%), mucoepidermoid carcinoma (17.9%) and adenoid cystic carcinoma (11.9%) were the more frequent neoplasms. All retromolar cases were malignant and all submandibular gland tumours were benign. We found a high proportion of salivary gland neoplasms in children. Our results showed that differences of the studied tumours among our sample and previously reported series exist. These differences can be related to race and geographical location.

  11. Procedures for sampling and sample reduction within quality assurance systems for solid biofuels

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    The objective of this experimental study on sampling was to determine the size and number of samples of biofuels required (taken at two sampling points in each case) and to compare two methods of sampling. The first objective of the sample-reduction exercise was to compare the reliability of various sampling methods, and the second objective was to measure the variations introduced as a result of reducing the sample size to form suitable test portions. The materials studied were sawdust, wood chips, wood pellets and bales of straw, and these were analysed for moisture, ash, particle size and chloride. The sampling procedures are described. The study was conducted in Scandinavia. The results of the study were presented in Leipzig in October 2004. The work was carried out as part of the UK's DTI Technology Programme: New and Renewable Energy.

  12. Studies on 129I and 14C in environmental samples by AMS

    International Nuclear Information System (INIS)

    Muramatsu, Yasuyuki

    2010-01-01

    We have carried out studies on 129 I and 14 C in environmental samples by AMS (accelerator mass spectrometry). In this paper summary of our results are described. Iodine is an essential element for humans and it pays an important role in thyroid gland. There are more than 30 isotopes of iodine. Among radioiodines 129 I has the longest half-life (1.57x10 7 y). This nuclide is released into the environment from nuclear weapons test, accidents of nuclear facilities (e.g. Chernobyl accident) and operation of spent fuel reprocessing plants. Since soil accumulates iodine, we have focused on the levels of both 129 I and 127 I in surface soils. In our previous studies, we used NAA (neutron activation analysis) for the determination. However, due to the limitation of its analytical sensitivity we could not detect 129 I in samples from background areas. In this study we have analyzed 129 I/ 127 I ratios by AMS and 127 I concentrations by ICP-MS (inductively coupled plasma spectrometry) after separation of iodine from soil by pyrohydrolysis and solvent extraction techniques. Using these methods, we have analyzed samples collected from different areas in Japan. Analytical results for surface soils collected from background areas were in the ranges 1.4 x 10 -5 - 4.6 x 10 -3 Bq/Kg as 129 I concentrations and 3.9 x 10 -11 - 3.0 x 10 -8 as 129 I/ 127 I ratios. The 129 I levels in Tokaimura, where a spent fuel reprocessing plant is located, were one to three orders of magnitude higher than those in background samples. The levels were higher in forest soils than those in field and rice paddy soils due to the interception effect of atmospheric 129 I by tree canopies. A wide range of stable iodine concentrations (0.4-143ppm) was observed. Rice paddy soils contained significantly lower iodine than forest and upland field soils. This should be explained by the desorption of iodine from the rice paddies due to microbial activities during the cultivation. Vertical distributions of 129 I

  13. Respondent-Driven Sampling – Testing Assumptions: Sampling with Replacement

    Directory of Open Access Journals (Sweden)

    Barash Vladimir D.

    2016-03-01

    Full Text Available Classical Respondent-Driven Sampling (RDS estimators are based on a Markov Process model in which sampling occurs with replacement. Given that respondents generally cannot be interviewed more than once, this assumption is counterfactual. We join recent work by Gile and Handcock in exploring the implications of the sampling-with-replacement assumption for bias of RDS estimators. We differ from previous studies in examining a wider range of sampling fractions and in using not only simulations but also formal proofs. One key finding is that RDS estimates are surprisingly stable even in the presence of substantial sampling fractions. Our analyses show that the sampling-with-replacement assumption is a minor contributor to bias for sampling fractions under 40%, and bias is negligible for the 20% or smaller sampling fractions typical of field applications of RDS.

  14. Genotyping faecal samples of Bengal tiger Panthera tigris tigris for population estimation: A pilot study

    Directory of Open Access Journals (Sweden)

    Singh Lalji

    2006-10-01

    Full Text Available Abstract Background Bengal tiger Panthera tigris tigris the National Animal of India, is an endangered species. Estimating populations for such species is the main objective for designing conservation measures and for evaluating those that are already in place. Due to the tiger's cryptic and secretive behaviour, it is not possible to enumerate and monitor its populations through direct observations; instead indirect methods have always been used for studying tigers in the wild. DNA methods based on non-invasive sampling have not been attempted so far for tiger population studies in India. We describe here a pilot study using DNA extracted from faecal samples of tigers for the purpose of population estimation. Results In this study, PCR primers were developed based on tiger-specific variations in the mitochondrial cytochrome b for reliably identifying tiger faecal samples from those of sympatric carnivores. Microsatellite markers were developed for the identification of individual tigers with a sibling Probability of Identity of 0.005 that can distinguish even closely related individuals with 99.9% certainty. The effectiveness of using field-collected tiger faecal samples for DNA analysis was evaluated by sampling, identification and subsequently genotyping samples from two protected areas in southern India. Conclusion Our results demonstrate the feasibility of using tiger faecal matter as a potential source of DNA for population estimation of tigers in protected areas in India in addition to the methods currently in use.

  15. Study of Bacterial Samples Using Laser Induced Breakdown Spectroscopy

    International Nuclear Information System (INIS)

    Farooq W A; Atif M; Tawfik W; Alsalhi M S; Alahmed Z A; Sarfraz M; Singh J P

    2014-01-01

    Laser-induced breakdown spectroscopy (LIBS) technique has been applied to investigate two different types of bacteria, Escherichia coli (B1) and Micrococcus luteus (B2) deposited on glass slides using Spectrolaser 7000. LIBS spectra were analyzed using spectrolaser software. LIBS spectrum of glass substrate was compared with bacteria spectra. Ca, Mg, Na, K, P, S, Cl, Fe, Al, Mn, Cu, C, H and CN-band appeared in bacterial samples in air. Two carbon lines at 193.02 nm, 247.88 nm and one hydrogen line at 656.28 nm with intensity ratios of 1.9, 1.83 and 1.53 appeared in bacterial samples B1 and B2 respectively. Carbon and hydrogen are the important components of the bio-samples like bacteria and other cancer cells. Investigation on LIBS spectra of the samples in He and Ar atmospheres is also presented. Ni lines appeared only in B2 sample in Ar atmosphere. From the present experimental results we are able to show that LIBS technique has a potential in the identification and discrimination of different types of bacteria. (plasma technology)

  16. A sample cell to study hydrate formation with x-ray scattering

    International Nuclear Information System (INIS)

    Conrad, Heiko; Lehmkuehler, Felix; Sternemann, Christian; Feroughi, Omid; Tolan, Metin; Simonelli, Laura; Huotari, Simo

    2009-01-01

    We present a new sample cell for measuring nonresonant inelastic x-ray scattering spectra of a tetrahydrofuran (THF)-water liquid mixture and THF hydrate. The hydrate is formed inside the cell after nucleation seeds have been offered by a special magnetic stirring mechanism. Hydrate formation was verified by wide angle x-ray scattering and nonresonant x-ray Raman scattering spectra at the oxygen K-edge. A broad range of scattering angles can be studied with this cell which is necessary for momentum transfer dependent inelastic x-ray scattering. This cell is ideal to examine other liquid hydrate formers or other liquid samples, which have to be mixed in situ during the measurements.

  17. Determination of 226Ra by gamma spectrometry: study of packaging vial of sample for analysis

    International Nuclear Information System (INIS)

    Carneiro, Andre Cavalcanti

    2015-01-01

    Determination of radioactivity levels of 226 Ra by gamma spectrometry in a sample is based on measurements of 214 Pb and 214 Bi, daughters of 222 Rn. Because radon is a gas, it can leak from the sample vial or accumulate on the upper empty it. If the vial has any crack, there will be loss of gas, which will cause error in determining the 226 Ra concentration. One possible cause of cracks in the vials, that houses standards and samples, is the radiolysis action in the vial material, usually a polymer. As the demand 226 Ra analysis in different matrices (geological samples, food, plants, etc.) is increasing, it was decided to study some polymer vials available on the market, to verify the feasibility to be used when is applied the analysis method using gamma spectrometry. Four types of polymer vials have been studied. The radiation doses in walls of the vials caused by natural radionuclides present in the sample were simulated using gamma irradiation. Tests, such as compressive strength test and tightness, were applied to the irradiated and non-irradiated vials. First, to verify the effect of radiolysis on the vial material and also if there was 222 Rn diffusion in their walls. These preliminary results pointed out that the acrylic vials are the best option of packaging samples for analysis. This study should be repeated in a larger number of samples for a better evaluation. (author)

  18. The 4-vessel Sampling Approach to Integrative Studies of Human Placental Physiology In Vivo.

    Science.gov (United States)

    Holme, Ane M; Holm, Maia B; Roland, Marie C P; Horne, Hildegunn; Michelsen, Trond M; Haugen, Guttorm; Henriksen, Tore

    2017-08-02

    The human placenta is highly inaccessible for research while still in utero. The current understanding of human placental physiology in vivo is therefore largely based on animal studies, despite the high diversity among species in placental anatomy, hemodynamics and duration of the pregnancy. The vast majority of human placenta studies are ex vivo perfusion studies or in vitro trophoblast studies. Although in vitro studies and animal models are essential, extrapolation of the results from such studies to the human placenta in vivo is uncertain. We aimed to study human placenta physiology in vivo at term, and present a detailed protocol of the method. Exploiting the intraabdominal access to the uterine vein just before the uterine incision during planned cesarean section, we collect blood samples from the incoming and outgoing vessels on the maternal and fetal sides of the placenta. When combining concentration measurements from blood samples with volume blood flow measurements, we are able to quantify placental and fetal uptake and release of any compound. Furthermore, placental tissue samples from the same mother-fetus pairs can provide measurements of transporter density and activity and other aspects of placental functions in vivo. Through this integrative use of the 4-vessel sampling method we are able to test some of the current concepts of placental nutrient transfer and metabolism in vivo, both in normal and pathological pregnancies. Furthermore, this method enables the identification of substances secreted by the placenta to the maternal circulation, which could be an important contribution to the search for biomarkers of placenta dysfunction.

  19. Sampling soils for 137Cs using various field-sampling volumes

    International Nuclear Information System (INIS)

    Nyhan, J.W.; Schofield, T.G.; White, G.C.; Trujillo, G.

    1981-10-01

    The sediments from a liquid effluent receiving area at the Los Alamos National Laboratory and soils from intensive study area in the fallout pathway of Trinity were sampled for 137 Cs using 25-, 500-, 2500-, and 12 500-cm 3 field sampling volumes. A highly replicated sampling program was used to determine mean concentrations and inventories of 137 Cs at each site, as well as estimates of spatial, aliquoting, and counting variance components of the radionuclide data. The sampling methods were also analyzed as a function of soil size fractions collected in each field sampling volume and of the total cost of the program for a given variation in the radionuclide survey results. Coefficients of variation (CV) of 137 Cs inventory estimates ranged from 0.063 to 0.14 for Mortandad Canyon sediments, where CV values for Trinity soils were observed from 0.38 to 0.57. Spatial variance components of 137 Cs concentration data were usually found to be larger than either the aliquoting or counting variance estimates and were inversely related to field sampling volume at the Trinity intensive site. Subsequent optimization studies of the sampling schemes demonstrated that each aliquot should be counted once, and that only 2 to 4 aliquots out of an many as 30 collected need be assayed for 137 Cs. The optimization studies showed that as sample costs increased to 45 man-hours of labor per sample, the variance of the mean 137 Cs concentration decreased dramatically, but decreased very little with additional labor

  20. Studying the sampling representativeness in the NPP ventilation ducts

    International Nuclear Information System (INIS)

    Sosnovskij, R.I.; Fedchenko, T.K.; Minin, S.A.

    2000-01-01

    Measurements of the gas and aerosol voluminous activity in the NPP ventilation ducts are an important source of information on the radiation contaminants ingress into the environmental medium. These measurements include sampling, samples transport and proper measurements. The work is devoted to calculation of metrological characteristics of the sampling systems for the NPP gas-aerosol releases by different parameters of these systems and ventilation ducts. The results obtained are intended for application by designing such systems and their metrological certification [ru

  1. Study of probe-sample distance for biomedical spectra measurement

    Directory of Open Access Journals (Sweden)

    Li Lei

    2011-11-01

    Full Text Available Abstract Background Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. Method In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in designing fiber optic probes for biomedical spectra measurement. This model was in general applicable to probes with single or multiple fibers at an arbitrary incident angle. In order to demonstrate the theory, a fluorescence spectrometer was used to measure the fluorescence of human finger skin at various probe-sample distances. The fluorescence spectrum and the total fluorescence intensity were recorded. Results The theoretical results show that for single fiber probes, contact measurement always provides the best results. While for multi-fiber probes, there is an optimal probe distance. When a 400- μm excitation fiber is used to deliver the light to the skin and another six 400- μm fibers surrounding the excitation fiber are used to collect the fluorescence signal, the experimental results show that human finger skin has very strong fluorescence between 475 nm and 700 nm under 450 nm excitation. The fluorescence intensity is heavily dependent on the probe-sample distance and there is an optimal probe distance. Conclusions We investigated a number of probe-sample configurations and found that contact measurement could be the primary choice for single-fiber probes, but was very inefficient for multi-fiber probes. There was an optimal probe-sample distance for multi-fiber probes. By carefully choosing the probe-sample distance, the collection efficiency could be enhanced by 5-10 times. Our experiments demonstrated that the experimental results of the probe-sample distance dependence of collection efficiency in multi-fiber probes were in general agreement with our theory.

  2. Planning Considerations for a Mars Sample Receiving Facility: Summary and Interpretation of Three Design Studies

    Science.gov (United States)

    Beaty, David W.; Allen, Carlton C.; Bass, Deborah S.; Buxbaum, Karen L.; Campbell, James K.; Lindstrom, David J.; Miller, Sylvia L.; Papanastassiou, Dimitri A.

    2009-10-01

    It has been widely understood for many years that an essential component of a Mars Sample Return mission is a Sample Receiving Facility (SRF). The purpose of such a facility would be to take delivery of the flight hardware that lands on Earth, open the spacecraft and extract the sample container and samples, and conduct an agreed-upon test protocol, while ensuring strict containment and contamination control of the samples while in the SRF. Any samples that are found to be non-hazardous (or are rendered non-hazardous by sterilization) would then be transferred to long-term curation. Although the general concept of an SRF is relatively straightforward, there has been considerable discussion about implementation planning. The Mars Exploration Program carried out an analysis of the attributes of an SRF to establish its scope, including minimum size and functionality, budgetary requirements (capital cost, operating costs, cost profile), and development schedule. The approach was to arrange for three independent design studies, each led by an architectural design firm, and compare the results. While there were many design elements in common identified by each study team, there were significant differences in the way human operators were to interact with the systems. In aggregate, the design studies provided insight into the attributes of a future SRF and the complex factors to consider for future programmatic planning.

  3. Effect of dissolved organic matter on pre-equilibrium passive sampling: A predictive QSAR modeling study.

    Science.gov (United States)

    Lin, Wei; Jiang, Ruifen; Shen, Yong; Xiong, Yaxin; Hu, Sizi; Xu, Jianqiao; Ouyang, Gangfeng

    2018-04-13

    Pre-equilibrium passive sampling is a simple and promising technique for studying sampling kinetics, which is crucial to determine the distribution, transfer and fate of hydrophobic organic compounds (HOCs) in environmental water and organisms. Environmental water samples contain complex matrices that complicate the traditional calibration process for obtaining the accurate rate constants. This study proposed a QSAR model to predict the sampling rate constants of HOCs (polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and pesticides) in aqueous systems containing complex matrices. A homemade flow-through system was established to simulate an actual aqueous environment containing dissolved organic matter (DOM) i.e. humic acid (HA) and (2-Hydroxypropyl)-β-cyclodextrin (β-HPCD)), and to obtain the experimental rate constants. Then, a quantitative structure-activity relationship (QSAR) model using Genetic Algorithm-Multiple Linear Regression (GA-MLR) was found to correlate the experimental rate constants to the system state including physicochemical parameters of the HOCs and DOM which were calculated and selected as descriptors by Density Functional Theory (DFT) and Chem 3D. The experimental results showed that the rate constants significantly increased as the concentration of DOM increased, and the enhancement factors of 70-fold and 34-fold were observed for the HOCs in HA and β-HPCD, respectively. The established QSAR model was validated as credible (R Adj. 2 =0.862) and predictable (Q 2 =0.835) in estimating the rate constants of HOCs for complex aqueous sampling, and a probable mechanism was developed by comparison to the reported theoretical study. The present study established a QSAR model of passive sampling rate constants and calibrated the effect of DOM on the sampling kinetics. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Reliability of different sampling densities for estimating and mapping lichen diversity in biomonitoring studies

    International Nuclear Information System (INIS)

    Ferretti, M.; Brambilla, E.; Brunialti, G.; Fornasier, F.; Mazzali, C.; Giordani, P.; Nimis, P.L.

    2004-01-01

    Sampling requirements related to lichen biomonitoring include optimal sampling density for obtaining precise and unbiased estimates of population parameters and maps of known reliability. Two available datasets on a sub-national scale in Italy were used to determine a cost-effective sampling density to be adopted in medium-to-large-scale biomonitoring studies. As expected, the relative error in the mean Lichen Biodiversity (Italian acronym: BL) values and the error associated with the interpolation of BL values for (unmeasured) grid cells increased as the sampling density decreased. However, the increase in size of the error was not linear and even a considerable reduction (up to 50%) in the original sampling effort led to a far smaller increase in errors in the mean estimates (<6%) and in mapping (<18%) as compared with the original sampling densities. A reduction in the sampling effort can result in considerable savings of resources, which can then be used for a more detailed investigation of potentially problematic areas. It is, however, necessary to decide the acceptable level of precision at the design stage of the investigation, so as to select the proper sampling density. - An acceptable level of precision must be decided before determining a sampling design

  5. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study.

    Science.gov (United States)

    Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C

    2015-12-01

    Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.

  6. Treatability studies on different refinery wastewater samples using high-throughput microbial electrolysis cells (MECs)

    KAUST Repository

    Ren, Lijiao; Siegert, Michael; Ivanov, Ivan; Pisciotta, John M.; Logan, Bruce E.

    2013-01-01

    High-throughput microbial electrolysis cells (MECs) were used to perform treatability studies on many different refinery wastewater samples all having appreciably different characteristics, which resulted in large differences in current generation. A de-oiled refinery wastewater sample from one site (DOW1) produced the best results, with 2.1±0.2A/m2 (maximum current density), 79% chemical oxygen demand removal, and 82% headspace biological oxygen demand removal. These results were similar to those obtained using domestic wastewater. Two other de-oiled refinery wastewater samples also showed good performance, with a de-oiled oily sewer sample producing less current. A stabilization lagoon sample and a stripped sour wastewater sample failed to produce appreciable current. Electricity production, organics removal, and startup time were improved when the anode was first acclimated to domestic wastewater. These results show mini-MECs are an effective method for evaluating treatability of different wastewaters. © 2013 Elsevier Ltd.

  7. Treatability studies on different refinery wastewater samples using high-throughput microbial electrolysis cells (MECs)

    KAUST Repository

    Ren, Lijiao

    2013-05-01

    High-throughput microbial electrolysis cells (MECs) were used to perform treatability studies on many different refinery wastewater samples all having appreciably different characteristics, which resulted in large differences in current generation. A de-oiled refinery wastewater sample from one site (DOW1) produced the best results, with 2.1±0.2A/m2 (maximum current density), 79% chemical oxygen demand removal, and 82% headspace biological oxygen demand removal. These results were similar to those obtained using domestic wastewater. Two other de-oiled refinery wastewater samples also showed good performance, with a de-oiled oily sewer sample producing less current. A stabilization lagoon sample and a stripped sour wastewater sample failed to produce appreciable current. Electricity production, organics removal, and startup time were improved when the anode was first acclimated to domestic wastewater. These results show mini-MECs are an effective method for evaluating treatability of different wastewaters. © 2013 Elsevier Ltd.

  8. Comparison of POCIS passive samplers vs. composite water sampling: A case study.

    Science.gov (United States)

    Criquet, Justine; Dumoulin, David; Howsam, Michael; Mondamert, Leslie; Goossens, Jean-François; Prygiel, Jean; Billon, Gabriel

    2017-12-31

    The relevance of Polar Organic Chemical Integrative Samplers (POCIS) was evaluated for the assessment of concentrations of 46 pesticides and 19 pharmaceuticals in a small, peri-urban river with multi-origin inputs. Throughout the period of POCIS deployment, 24h-average water samples were collected automatically, and showed the rapid temporal evolution of concentrations of several micropollutants, as well as permitting the calculation of average concentrations in the water phase for comparison with those estimated from POCIS passive samplers. In the daily water samples, cyproconazol, epoxyconazol and imidacloprid showed high temporal variations with concentrations ranging from under the limit of detection up to several hundreds of ngL -1 . Erythromycin, cyprofloxacin and iopromide also increased rapidly up to tens of ngL -1 within a few days. Conversely, atrazine, caffeine, diclofenac, and to a lesser extent carbamazepine and sucralose, were systematically present in the water samples and showed limited variation in concentrations. For most of the substances studied here, the passive samplers gave reliable average concentrations between the minimal and maximal daily concentrations during the time of deployment. For pesticides, a relatively good correlation was clearly established (R 2 =0.89) between the concentrations obtained by POCIS and those gained from average water samples. A slight underestimation of the concentration by POCIS can be attributed to inappropriate sampling rates extracted from the literature and for our system, and new values are proposed. Considering the all data set, 75% of the results indicate a relatively good agreement between the POCIS and the average water samples concentration (values of the ratio ranging between 0,33 and 3). Note further that this agreement between these concentrations remains valid considering different sampling rates extracted from the literature. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Sampling design and procedures for fixed surface-water sites in the Georgia-Florida coastal plain study unit, 1993

    Science.gov (United States)

    Hatzell, H.H.; Oaksford, E.T.; Asbury, C.E.

    1995-01-01

    The implementation of design guidelines for the National Water-Quality Assessment (NAWQA) Program has resulted in the development of new sampling procedures and the modification of existing procedures commonly used in the Water Resources Division of the U.S. Geological Survey. The Georgia-Florida Coastal Plain (GAFL) study unit began the intensive data collection phase of the program in October 1992. This report documents the implementation of the NAWQA guidelines by describing the sampling design and procedures for collecting surface-water samples in the GAFL study unit in 1993. This documentation is provided for agencies that use water-quality data and for future study units that will be entering the intensive phase of data collection. The sampling design is intended to account for large- and small-scale spatial variations, and temporal variations in water quality for the study area. Nine fixed sites were selected in drainage basins of different sizes and different land-use characteristics located in different land-resource provinces. Each of the nine fixed sites was sampled regularly for a combination of six constituent groups composed of physical and chemical constituents: field measurements, major ions and metals, nutrients, organic carbon, pesticides, and suspended sediments. Some sites were also sampled during high-flow conditions and storm events. Discussion of the sampling procedure is divided into three phases: sample collection, sample splitting, and sample processing. A cone splitter was used to split water samples for the analysis of the sampling constituent groups except organic carbon from approximately nine liters of stream water collected at four fixed sites that were sampled intensively. An example of the sample splitting schemes designed to provide the sample volumes required for each sample constituent group is described in detail. Information about onsite sample processing has been organized into a flowchart that describes a pathway for each of

  10. Sampling Development

    Science.gov (United States)

    Adolph, Karen E.; Robinson, Scott R.

    2011-01-01

    Research in developmental psychology requires sampling at different time points. Accurate depictions of developmental change provide a foundation for further empirical studies and theories about developmental mechanisms. However, overreliance on widely spaced sampling intervals in cross-sectional and longitudinal designs threatens the validity of…

  11. Study of gastric cancer samples using terahertz techniques

    Science.gov (United States)

    Wahaia, Faustino; Kasalynas, Irmantas; Seliuta, Dalius; Molis, Gediminas; Urbanowicz, Andrzej; Carvalho Silva, Catia D.; Carneiro, Fatima; Valusis, Gintaras; Granja, Pedro L.

    2014-08-01

    In the present work, samples of healthy and adenocarcinoma-affected human gastric tissue were analyzed using transmission time-domain THz spectroscopy (THz-TDS) and spectroscopic THz imaging at 201 and 590 GHz. The work shows that it is possible to distinguish between normal and cancerous regions in dried and paraffin-embedded samples. Plots of absorption coefficient α and refractive index n of normal and cancer affected tissues, as well as 2-D transmission THz images are presented and the conditions for discrimination between normal and affected tissues are discussed.

  12. Selection bias in population-based cancer case-control studies due to incomplete sampling frame coverage.

    Science.gov (United States)

    Walsh, Matthew C; Trentham-Dietz, Amy; Gangnon, Ronald E; Nieto, F Javier; Newcomb, Polly A; Palta, Mari

    2012-06-01

    Increasing numbers of individuals are choosing to opt out of population-based sampling frames due to privacy concerns. This is especially a problem in the selection of controls for case-control studies, as the cases often arise from relatively complete population-based registries, whereas control selection requires a sampling frame. If opt out is also related to risk factors, bias can arise. We linked breast cancer cases who reported having a valid driver's license from the 2004-2008 Wisconsin women's health study (N = 2,988) with a master list of licensed drivers from the Wisconsin Department of Transportation (WDOT). This master list excludes Wisconsin drivers that requested their information not be sold by the state. Multivariate-adjusted selection probability ratios (SPR) were calculated to estimate potential bias when using this driver's license sampling frame to select controls. A total of 962 cases (32%) had opted out of the WDOT sampling frame. Cases age <40 (SPR = 0.90), income either unreported (SPR = 0.89) or greater than $50,000 (SPR = 0.94), lower parity (SPR = 0.96 per one-child decrease), and hormone use (SPR = 0.93) were significantly less likely to be covered by the WDOT sampling frame (α = 0.05 level). Our results indicate the potential for selection bias due to differential opt out between various demographic and behavioral subgroups of controls. As selection bias may differ by exposure and study base, the assessment of potential bias needs to be ongoing. SPRs can be used to predict the direction of bias when cases and controls stem from different sampling frames in population-based case-control studies.

  13. Outpatient Tinnitus Clinic, Self-Help Web Platform, or Mobile Application to Recruit Tinnitus Study Samples?

    Directory of Open Access Journals (Sweden)

    Thomas Probst

    2017-04-01

    Full Text Available For understanding the heterogeneity of tinnitus, large samples are required. However, investigations on how samples recruited by different methods differ from each other are lacking. In the present study, three large samples each recruited by different means were compared: N = 5017 individuals registered at a self-help web platform for tinnitus (crowdsourcing platform Tinnitus Talk, N = 867 users of a smart mobile application for tinnitus (crowdsensing platform TrackYourTinnitus, and N = 3786 patients contacting an outpatient tinnitus clinic (Tinnitus Center of the University Hospital Regensburg. The three samples were compared regarding age, gender, and duration of tinnitus (month or years perceiving tinnitus; subjective report using chi-squared tests. The three samples significantly differed from each other in age, gender and tinnitus duration (p < 0.05. Users of the TrackYourTinnitus crowdsensing platform were younger, users of the Tinnitus Talk crowdsourcing platform had more often female gender, and users of both newer technologies (crowdsourcing and crowdsensing had more frequently acute/subacute tinnitus (<3 months and 4–6 months as well as a very long tinnitus duration (>20 years. The implications of these findings for clinical research are that newer technologies such as crowdsourcing and crowdsensing platforms offer the possibility to reach individuals hard to get in contact with at an outpatient tinnitus clinic. Depending on the aims and the inclusion/exclusion criteria of a given study, different recruiting strategies (clinic and/or newer technologies offer different advantages and disadvantages. In general, the representativeness of study results might be increased when tinnitus study samples are recruited in the clinic as well as via crowdsourcing and crowdsensing.

  14. Sampling and sample processing in pesticide residue analysis.

    Science.gov (United States)

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  15. Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies: Comparing lipids and metabolites in serum and DBS samples

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, Jennifer E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Casey, Cameron P. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Stratton, Kelly G. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zink, Erika M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Kim, Young-Mo [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zheng, Xueyun [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Monroe, Matthew E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Weitz, Karl K. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Bloodsworth, Kent J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Orton, Daniel J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Ibrahim, Yehia M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Moore, Ronald J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Lee, Christine G. [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Research Service, Portland Veterans Affairs Medical Center, Portland OR USA; Pedersen, Catherine [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Orwoll, Eric [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Smith, Richard D. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Burnum-Johnson, Kristin E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Baker, Erin S. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA

    2017-02-05

    The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules were identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.

  16. Evaluating sampling strategy for DNA barcoding study of coastal and inland halo-tolerant Poaceae and Chenopodiaceae: A case study for increased sample size.

    Science.gov (United States)

    Yao, Peng-Cheng; Gao, Hai-Yan; Wei, Ya-Nan; Zhang, Jian-Hang; Chen, Xiao-Yong; Li, Hong-Qing

    2017-01-01

    Environmental conditions in coastal salt marsh habitats have led to the development of specialist genetic adaptations. We evaluated six DNA barcode loci of the 53 species of Poaceae and 15 species of Chenopodiaceae from China's coastal salt marsh area and inland area. Our results indicate that the optimum DNA barcode was ITS for coastal salt-tolerant Poaceae and matK for the Chenopodiaceae. Sampling strategies for ten common species of Poaceae and Chenopodiaceae were analyzed according to optimum barcode. We found that by increasing the number of samples collected from the coastal salt marsh area on the basis of inland samples, the number of haplotypes of Arundinella hirta, Digitaria ciliaris, Eleusine indica, Imperata cylindrica, Setaria viridis, and Chenopodium glaucum increased, with a principal coordinate plot clearly showing increased distribution points. The results of a Mann-Whitney test showed that for Digitaria ciliaris, Eleusine indica, Imperata cylindrica, and Setaria viridis, the distribution of intraspecific genetic distances was significantly different when samples from the coastal salt marsh area were included (P Imperata cylindrica and Chenopodium album, average intraspecific distance tended to reach stability. These results indicate that the sample size for DNA barcode of globally distributed species should be increased to 11-15.

  17. A preliminary study on identification of Thai rice samples by INAA and statistical analysis

    Science.gov (United States)

    Kongsri, S.; Kukusamude, C.

    2017-09-01

    This study aims to investigate the elemental compositions in 93 Thai rice samples using instrumental neutron activation analysis (INAA) and to identify rice according to their types and rice cultivars using statistical analysis. As, Mg, Cl, Al, Br, Mn, K, Rb and Zn in Thai jasmine rice and Sung Yod rice samples were successfully determined by INAA. The accuracy and precision of the INAA method were verified by SRM 1568a Rice Flour. All elements were found to be in a good agreement with the certified values. The precisions in term of %RSD were lower than 7%. The LODs were obtained in range of 0.01 to 29 mg kg-1. The concentration of 9 elements distributed in Thai rice samples was evaluated and used as chemical indicators to identify the type of rice samples. The result found that Mg, Cl, As, Br, Mn, K, Rb, and Zn concentrations in Thai jasmine rice samples are significantly different but there was no evidence that Al is significantly different from concentration in Sung Yod rice samples at 95% confidence interval. Our results may provide preliminary information for discrimination of rice samples and may be useful database of Thai rice.

  18. Imitation and luck: an experimental study on social sampling

    NARCIS (Netherlands)

    Offerman, T.; Schotter, A.

    2007-01-01

    In this paper, we present the results of two experiments on social sampling. In both experiments, people are asked to make a risky decision in a situation where an idiosyncratic luck term a?ects their performance. Before they make their decision, people have the opportunity to sample others who have

  19. Experimental study on the particles deposition in the sampling duct

    Energy Technology Data Exchange (ETDEWEB)

    Vendel, J.; Charuau, J. [Institut de Protection et de Surete Nucleaire, Yvette (France)

    1995-02-01

    A high standard of protection against the harmful effects of radioactive aerosol dissemination requires a measurement, as representative as possible, of their concentration. This measurement depends on the techniques used for aerosol sampling and transfer to the detector, as well as on the location of the latter with respect to the potential sources. The aeraulic design of the apparatus is also an important factor. Once collected the aerosol particles often have to travel through a variably shaped duct to the measurement apparatus. This transport is responsible for losses due to the particles deposition on the walls, leading to a distortion on the concentration measurements and a change in the particle size distribution. To estimate and minimize measurement errors it is important to determine the optimal transport conditions when designing a duct; its diameter and material, the radius of curvature of the bends and the flow conditions must be defined in particular. This paper presents an experimental study in order to determine, for each deposition mechanism, the retained fraction, or the deposition velocity for different flow regimes. This study has pointed out that it exists a favourable flow regime for the particle transport through the sampling ducts (2 500 < Re < 5 000). It has been established, for any particle diameters, equations to predict the aerosol penetration in smooth-walled cylindrical metal ducts.

  20. Imitation and luck: an experimental study on social sampling

    NARCIS (Netherlands)

    Offerman, T.; Schotter, A.

    2008-01-01

    In this paper, we present the results of two experiments on social sampling, where people make a risky decision after they have sampled the behavior of others who have done exactly the same problem before them. In an individual decision making problem as well as in the take-over game, the simple

  1. Automated sample preparation station for studying self-diffusion in porous solids with NMR spectroscopy

    Science.gov (United States)

    Hedin, Niklas; DeMartin, Gregory J.; Reyes, Sebastián C.

    2006-03-01

    In studies of gas diffusion in porous solids with nuclear magnetic resonance (NMR) spectroscopy the sample preparation procedure becomes very important. An apparatus is presented here that pretreats the sample ex situ and accurately sets the desired pressure and temperature within the NMR tube prior to its introduction in the spectrometer. The gas manifold that supplies the NMR tube is also connected to a microbalance containing another portion of the same sample, which is kept at the same temperature as the sample in the NMR tube. This arrangement permits the simultaneous measurement of the adsorption loading on the sample, which is required for the interpretation of the NMR diffusion experiments. Furthermore, to ensure a good seal of the NMR tube, a hybrid valve design composed of titanium, a Teflon® seat, and Kalrez® O-rings is utilized. A computer controlled algorithm ensures the accuracy and reproducibility of all the procedures, enabling the NMR diffusion experiments to be performed at well controlled conditions of pressure, temperature, and amount of gas adsorbed on the porous sample.

  2. Water quality monitoring: A comparative case study of municipal and Curtin Sarawak's lake samples

    Science.gov (United States)

    Anand Kumar, A.; Jaison, J.; Prabakaran, K.; Nagarajan, R.; Chan, Y. S.

    2016-03-01

    In this study, particle size distribution and zeta potential of the suspended particles in municipal water and lake surface water of Curtin Sarawak's lake were compared and the samples were analysed using dynamic light scattering method. High concentration of suspended particles affects the water quality as well as suppresses the aquatic photosynthetic systems. A new approach has been carried out in the current work to determine the particle size distribution and zeta potential of the suspended particles present in the water samples. The results for the lake samples showed that the particle size ranges from 180nm to 1345nm and the zeta potential values ranges from -8.58 mV to -26.1 mV. High zeta potential value was observed in the surface water samples of Curtin Sarawak's lake compared to the municipal water. The zeta potential values represent that the suspended particles are stable and chances of agglomeration is lower in lake water samples. Moreover, the effects of physico-chemical parameters on zeta potential of the water samples were also discussed.

  3. Study of lead pollution in air, soil and water samples of Quetta city

    International Nuclear Information System (INIS)

    Khan, M.; Khan, G.M.; Akbar, S.; Panezai, M.A.; Haq, Z.U.

    2011-01-01

    This study briefly presents the collected data of lead pollution in the environment of Quetta City in Balochistan, Pakistan. The samples were collected from different sites. The analysis of lead was carried out in underground water samples, the exhaust of different vehicles, roadside and sewage soils from selected points of Quetta City. The average discharge resulted in deposition by motorcycles (29.12 g/h), cars (44.47 g/h), wagons (176.54 g/h) and buses (141.52 g/h). The maximum deposition was 222.96 g/h from auto-rickshaws. The value for lead in smoke of different vehicles seems quite high when extrapolated to the large number of such vehicles for a longer time. The concentration of lead in roadside soil varied from 73.3 mg/kg (T and T closed colony) to 731.9 mg/kg (Sirki road bus-stop). The average content of lead in sewage soil of City Nala is 1250.6 mg/kg. The level of lead was more than WHO standards for such soils. The lead quantity in all 24 tube- well water samples, was slightly above the WHO standards (10 macro g/L).The results of this study were comparable to similar study in twin cities of Rawalpindi and islamabad. (author)

  4. Soil sampling

    International Nuclear Information System (INIS)

    Fortunati, G.U.; Banfi, C.; Pasturenzi, M.

    1994-01-01

    This study attempts to survey the problems associated with techniques and strategies of soil sampling. Keeping in mind the well defined objectives of a sampling campaign, the aim was to highlight the most important aspect of representativeness of samples as a function of the available resources. Particular emphasis was given to the techniques and particularly to a description of the many types of samplers which are in use. The procedures and techniques employed during the investigations following the Seveso accident are described. (orig.)

  5. A study of diabetes mellitus within a large sample of Australian twins

    DEFF Research Database (Denmark)

    Condon, Julianne; Shaw, Joanne E; Luciano, Michelle

    2008-01-01

    with type 2 diabetes (T2D), 41 female pairs with gestational diabetes (GD), 5 pairs with impaired glucose tolerance (IGT) and one pair with MODY. Heritabilities of T1D, T2D and GD were all high, but our samples did not have the power to detect effects of shared environment unless they were very large......Twin studies of diabetes mellitus can help elucidate genetic and environmental factors in etiology and can provide valuable biological samples for testing functional hypotheses, for example using expression and methylation studies of discordant pairs. We searched the volunteer Australian Twin...... Registry (19,387 pairs) for twins with diabetes using disease checklists from nine different surveys conducted from 1980-2000. After follow-up questionnaires to the twins and their doctors to confirm diagnoses, we eventually identified 46 pairs where one or both had type 1 diabetes (T1D), 113 pairs...

  6. Using Dried Blood Spot Sampling to Improve Data Quality and Reduce Animal Use in Mouse Pharmacokinetic Studies

    Science.gov (United States)

    Wickremsinhe, Enaksha R; Perkins, Everett J

    2015-01-01

    Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 µL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal—often to a single collection per mouse—thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 µL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study. PMID:25836959

  7. A topological analysis of large-scale structure, studied using the CMASS sample of SDSS-III

    International Nuclear Information System (INIS)

    Parihar, Prachi; Gott, J. Richard III; Vogeley, Michael S.; Choi, Yun-Young; Kim, Juhan; Kim, Sungsoo S.; Speare, Robert; Brownstein, Joel R.; Brinkmann, J.

    2014-01-01

    We study the three-dimensional genus topology of large-scale structure using the northern region of the CMASS Data Release 10 (DR10) sample of the SDSS-III Baryon Oscillation Spectroscopic Survey. We select galaxies with redshift 0.452 < z < 0.625 and with a stellar mass M stellar > 10 11.56 M ☉ . We study the topology at two smoothing lengths: R G = 21 h –1 Mpc and R G = 34 h –1 Mpc. The genus topology studied at the R G = 21 h –1 Mpc scale results in the highest genus amplitude observed to date. The CMASS sample yields a genus curve that is characteristic of one produced by Gaussian random phase initial conditions. The data thus support the standard model of inflation where random quantum fluctuations in the early universe produced Gaussian random phase initial conditions. Modest deviations in the observed genus from random phase are as expected from shot noise effects and the nonlinear evolution of structure. We suggest the use of a fitting formula motivated by perturbation theory to characterize the shift and asymmetries in the observed genus curve with a single parameter. We construct 54 mock SDSS CMASS surveys along the past light cone from the Horizon Run 3 (HR3) N-body simulations, where gravitationally bound dark matter subhalos are identified as the sites of galaxy formation. We study the genus topology of the HR3 mock surveys with the same geometry and sampling density as the observational sample and find the observed genus topology to be consistent with ΛCDM as simulated by the HR3 mock samples. We conclude that the topology of the large-scale structure in the SDSS CMASS sample is consistent with cosmological models having primordial Gaussian density fluctuations growing in accordance with general relativity to form galaxies in massive dark matter halos.

  8. Self-sampling for human papillomavirus DNA detection: a preliminary study of compliance and feasibility in BOLIVIA.

    Science.gov (United States)

    Surriabre, Pedro; Allende, Gustavo; Prado, Marcela; Cáceres, Leyddy; Bellot, Diego; Torrico, Andrea; Ustariz, Karina; Rojas, Shirley; Barriga, Jaime; Calle, Pamela; Villarroel, Ligia; Yañez, Rosse Mary; Baay, Marc; Rodriguez, Patricia; Fontaine, Véronique

    2017-12-22

    Cervical cancer incidence and mortality rates in Bolivia are among the highest in Latin America. This investigation aims to evaluate the possibility of using simple devices, e.g. a cotton swab and a glass slide, for self-sampling in order to detect human papillomavirus (HPV) DNA by PCR in cervico-vaginal cells. In the first phase of our study we evaluated the use of a glass slide as a transport medium for cervical cells. A physician took paired-cervical samples from 235 women. One sample was transported in Easyfix® solution and the other sample was smeared over a glass slide. Both were further analyzed and compared for human DNA recovery and HPV detection. A kappa value was determined to evaluate the agreement between the HPV DNA detection rates. In the second phase of the study, 222 women from the urban, peri-urban and rural regions of Cochabamba were requested to perform self-sampling using the following devices: a cotton swab combined with a glass slide, and a vaginal tampon. Women gave their opinion about the self-sampling technique. Finally, the agreement for high risk-HPV detection between self- and physician-collected samples was performed in 201 samples in order to evaluate the self-sampling technique. Firstly, the comparison between Easyfix® solution and the glass slide to transport clinical samples gave a good agreement for HPV DNA detection (κ = 0.71, 95% CI 0.60-0.81). Secondly, self-sampling, especially with cotton swab combined with glass slide, would generally be preferred over clinician sampling for a screening program based on HPV detection. Finally, we showed a good agreement between self- and physician collected samples for high risk-HPV detection (κ = 0.71, 95% CI 0.55-0.88). Simple devices such as a cotton swab and a glass slide can be used to perform self-sampling and HPV DNA detection. Furthermore, most Bolivian women preferred self-sampling over clinician-sampling for cervical cancer screening.

  9. Study of phosphors determination in biological samples; Estudo da determinacao de fosforo em amostras biologicas

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Rosangela Magda de

    1994-12-31

    In this paper, phosphors determination by neutron activation analysis in milk and bone samples was studied employing both instrumental and radiochemical separation methods. The analysis with radiochemistry separation consisted of the simultaneous irradiation of the samples and standards during 30 minutes, dissolution of the samples, hold back carrier, addition precipitation of phosphorus with ammonium phosphomolibdate (A.M.P.) and phosphorus-32 by counting by using Geiger-Mueller detector. The instrumental analysis consisted of the simultaneous irradiation of the samples and standards during 30 minutes, transfer of the samples into a counting planchet and measurement of the beta radiation emitted by phosphorus-32, after a suitable decay period. After the phosphorus analysis methods were established they were applied to both commercial milk and animal bone samples, and data obtained in the instrumental and radiochemical separation methods for each sample, were compared between themselves. In this work, it became possible to obtain analysis methods for phosphorus that can be applied independently of the sample quantity available, and the phosphorus content in the samples or interference that can be present in them. (author). 51 refs., 7 figs., 4 tabs.

  10. Water evaporation: a transition path sampling study.

    Science.gov (United States)

    Varilly, Patrick; Chandler, David

    2013-02-07

    We use transition path sampling to study evaporation in the SPC/E model of liquid water. On the basis of thousands of evaporation trajectories, we characterize the members of the transition state ensemble (TSE), which exhibit a liquid-vapor interface with predominantly negative mean curvature at the site of evaporation. We also find that after evaporation is complete, the distributions of translational and angular momenta of the evaporated water are Maxwellian with a temperature equal to that of the liquid. To characterize the evaporation trajectories in their entirety, we find that it suffices to project them onto just two coordinates: the distance of the evaporating molecule to the instantaneous liquid-vapor interface and the velocity of the water along the average interface normal. In this projected space, we find that the TSE is well-captured by a simple model of ballistic escape from a deep potential well, with no additional barrier to evaporation beyond the cohesive strength of the liquid. Equivalently, they are consistent with a near-unity probability for a water molecule impinging upon a liquid droplet to condense. These results agree with previous simulations and with some, but not all, recent experiments.

  11. Sampling design considerations for demographic studies: a case of colonial seabirds

    Science.gov (United States)

    Kendall, William L.; Converse, Sarah J.; Doherty, Paul F.; Naughton, Maura B.; Anders, Angela; Hines, James E.; Flint, Elizabeth

    2009-01-01

    For the purposes of making many informed conservation decisions, the main goal for data collection is to assess population status and allow prediction of the consequences of candidate management actions. Reducing the bias and variance of estimates of population parameters reduces uncertainty in population status and projections, thereby reducing the overall uncertainty under which a population manager must make a decision. In capture-recapture studies, imperfect detection of individuals, unobservable life-history states, local movement outside study areas, and tag loss can cause bias or precision problems with estimates of population parameters. Furthermore, excessive disturbance to individuals during capture?recapture sampling may be of concern because disturbance may have demographic consequences. We address these problems using as an example a monitoring program for Black-footed Albatross (Phoebastria nigripes) and Laysan Albatross (Phoebastria immutabilis) nesting populations in the northwestern Hawaiian Islands. To mitigate these estimation problems, we describe a synergistic combination of sampling design and modeling approaches. Solutions include multiple capture periods per season and multistate, robust design statistical models, dead recoveries and incidental observations, telemetry and data loggers, buffer areas around study plots to neutralize the effect of local movements outside study plots, and double banding and statistical models that account for band loss. We also present a variation on the robust capture?recapture design and a corresponding statistical model that minimizes disturbance to individuals. For the albatross case study, this less invasive robust design was more time efficient and, when used in combination with a traditional robust design, reduced the standard error of detection probability by 14% with only two hours of additional effort in the field. These field techniques and associated modeling approaches are applicable to studies of

  12. Development study of the X-ray scattering properties of a group of optically polished flat samples

    Science.gov (United States)

    Froechtenigt, J. F.

    1973-01-01

    A group of twelve optically polished flat samples were used to study the scattering of X-rays. The X-ray beam reflected from the twelve optical flat samples was analyzed by means of a long vacuum system of special design for these tests. The scattering measurements were made at 8.34A and 0.92 deg angle of incidence. The results for ten of the samples are comparable, the two exceptions being the fire polished samples.

  13. Studies on the radiocarbon sample from the shroud of turin

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, Raymond N. [Los Alamos National Laboratory, University of California, 1961 Cumbres Patio, Los Alamos, NM 87544 (United States)]. E-mail: rnrogers@att.net

    2005-01-20

    In 1988, radiocarbon laboratories at Arizona, Cambridge, and Zurich determined the age of a sample from the Shroud of Turin. They reported that the date of the cloth's production lay between A.D. 1260 and 1390 with 95% confidence. This came as a surprise in view of the technology used to produce the cloth, its chemical composition, and the lack of vanillin in its lignin. The results prompted questions about the validity of the sample. Preliminary estimates of the kinetics constants for the loss of vanillin from lignin indicate a much older age for the cloth than the radiocarbon analyses. The radiocarbon sampling area is uniquely coated with a yellow-brown plant gum containing dye lakes. Pyrolysis-mass-spectrometry results from the sample area coupled with microscopic and microchemical observations prove that the radiocarbon sample was not part of the original cloth of the Shroud of Turin. The radiocarbon date was thus not valid for determining the true age of the shroud.

  14. Studies on the radiocarbon sample from the shroud of turin

    International Nuclear Information System (INIS)

    Rogers, Raymond N.

    2005-01-01

    In 1988, radiocarbon laboratories at Arizona, Cambridge, and Zurich determined the age of a sample from the Shroud of Turin. They reported that the date of the cloth's production lay between A.D. 1260 and 1390 with 95% confidence. This came as a surprise in view of the technology used to produce the cloth, its chemical composition, and the lack of vanillin in its lignin. The results prompted questions about the validity of the sample. Preliminary estimates of the kinetics constants for the loss of vanillin from lignin indicate a much older age for the cloth than the radiocarbon analyses. The radiocarbon sampling area is uniquely coated with a yellow-brown plant gum containing dye lakes. Pyrolysis-mass-spectrometry results from the sample area coupled with microscopic and microchemical observations prove that the radiocarbon sample was not part of the original cloth of the Shroud of Turin. The radiocarbon date was thus not valid for determining the true age of the shroud

  15. Drop-on-Demand Sample Delivery for Studying Biocatalysts in Action at XFELs

    Science.gov (United States)

    Fuller, Franklin D.; Gul, Sheraz; Chatterjee, Ruchira; Burgie, Ernest S.; Young, Iris D.; Lebrette, Hugo; Srinivas, Vivek; Brewster, Aaron S.; Michels-Clark, Tara; Clinger, Jonathan A.; Andi, Babak; Ibrahim, Mohamed; Pastor, Ernest; de Lichtenberg, Casper; Hussein, Rana; Pollock, Christopher J.; Zhang, Miao; Stan, Claudiu A.; Kroll, Thomas; Fransson, Thomas; Weninger, Clemens; Kubin, Markus; Aller, Pierre; Lassalle, Louise; Bräuer, Philipp; Miller, Mitchell D.; Amin, Muhamed; Koroidov, Sergey; Roessler, Christian G.; Allaire, Marc; Sierra, Raymond G.; Docker, Peter T.; Glownia, James M.; Nelson, Silke; Koglin, Jason E.; Zhu, Diling; Chollet, Matthieu; Song, Sanghoon; Lemke, Henrik; Liang, Mengning; Sokaras, Dimosthenis; Alonso-Mori, Roberto; Zouni, Athina; Messinger, Johannes; Bergmann, Uwe; Boal, Amie K.; Bollinger, J. Martin; Krebs, Carsten; Högbom, Martin; Phillips, George N.; Vierstra, Richard D.; Sauter, Nicholas K.; Orville, Allen M.; Kern, Jan; Yachandra, Vittal K.; Yano, Junko

    2017-01-01

    X-ray crystallography at X-ray free-electron laser (XFEL) sources is a powerful method for studying macromolecules at biologically relevant temperatures. Moreover, when combined with complementary techniques like X-ray emission spectroscopy (XES), both global structures and chemical properties of metalloenzymes can be obtained concurrently, providing new insights into the interplay between the protein structure/dynamics and chemistry at an active site. Implementing such a multimodal approach can be compromised by conflicting requirements to optimize each individual method. In particular, the method used for sample delivery greatly impacts the data quality. We present here a new, robust way of delivering controlled sample amounts on demand using acoustic droplet ejection coupled with a conveyor belt drive that is optimized for crystallography and spectroscopy measurements of photochemical and chemical reactions over a wide range of time scales. Studies with photosystem II, the phytochrome photoreceptor, and ribonucleotide reductase R2 illustrate the power and versatility of this method. PMID:28250468

  16. Whole genome transcript profiling from fingerstick blood samples: a comparison and feasibility study

    Directory of Open Access Journals (Sweden)

    Williams Adam R

    2009-12-01

    Full Text Available Abstract Background Whole genome gene expression profiling has revolutionized research in the past decade especially with the advent of microarrays. Recently, there have been significant improvements in whole blood RNA isolation techniques which, through stabilization of RNA at the time of sample collection, avoid bias and artifacts introduced during sample handling. Despite these improvements, current human whole blood RNA stabilization/isolation kits are limited by the requirement of a venous blood sample of at least 2.5 mL. While fingerstick blood collection has been used for many different assays, there has yet to be a kit developed to isolate high quality RNA for use in gene expression studies from such small human samples. The clinical and field testing advantages of obtaining reliable and reproducible gene expression data from a fingerstick are many; it is less invasive, time saving, more mobile, and eliminates the need of a trained phlebotomist. Furthermore, this method could also be employed in small animal studies, i.e. mice, where larger sample collections often require sacrificing the animal. In this study, we offer a rapid and simple method to extract sufficient amounts of high quality total RNA from approximately 70 μl of whole blood collected via a fingerstick using a modified protocol of the commercially available Qiagen PAXgene RNA Blood Kit. Results From two sets of fingerstick collections, about 70 uL whole blood collected via finger lancet and capillary tube, we recovered an average of 252.6 ng total RNA with an average RIN of 9.3. The post-amplification yields for 50 ng of total RNA averaged at 7.0 ug cDNA. The cDNA hybridized to Affymetrix HG-U133 Plus 2.0 GeneChips had an average % Present call of 52.5%. Both fingerstick collections were highly correlated with r2 values ranging from 0.94 to 0.97. Similarly both fingerstick collections were highly correlated to the venous collection with r2 values ranging from 0.88 to 0

  17. Ophthalmologic changes related to radiation exposure and age in the adult health study sample, Hiroshima and Nagasaki

    International Nuclear Information System (INIS)

    Choshi, Kanji; Mishima, Hiromu; Takaku, Isao; Takase, Tomoko; Neriishi, Shotaro.

    1983-11-01

    A two-year ophthalmologic study of age- and radiation-related ophthalmologic lesions among the Adult Health Study (AHS) population of Hiroshima and Nagasaki was conducted at RERF in 1978-80. The study population in both cities was composed of all persons exposed to 100+ rad in the AHS, their controls, and all other persons in the AHS sample with a previous record of axial opacities or posterior subcapsular changes, and the in utero clinical sample. The ophthalmologic examination was conducted on 1,582 persons in Hiroshima and 719 persons in Nagasaki belonging to the AHS sample, and 67 persons in Hiroshima and 17 persons in Nagasaki belonging to the in utero clinical sample. Participation in the study was 42% of the eligible AHS sample in Hiroshima and 21% in Nagasaki, and 24% of the eligible in utero sample in Hiroshima and 26% in Nagasaki. Increased lenticular opacities, other lens changes, and loss of visual acuity and accommodation occurred with increasing age in both exposed and control subjects as manifestations of the normal aging process. A highly significant excess risk for all ages in the 300+ rad group in comparison to those in the control group was observed for both axial opacities and posterior subcapsular changes in Hiroshima, but not in Nagasaki. (J.P.N.)

  18. A model for estimating the minimum number of offspring to sample in studies of reproductive success.

    Science.gov (United States)

    Anderson, Joseph H; Ward, Eric J; Carlson, Stephanie M

    2011-01-01

    Molecular parentage permits studies of selection and evolution in fecund species with cryptic mating systems, such as fish, amphibians, and insects. However, there exists no method for estimating the number of offspring that must be assigned parentage to achieve robust estimates of reproductive success when only a fraction of offspring can be sampled. We constructed a 2-stage model that first estimated the mean (μ) and variance (v) in reproductive success from published studies on salmonid fishes and then sampled offspring from reproductive success distributions simulated from the μ and v estimates. Results provided strong support for modeling salmonid reproductive success via the negative binomial distribution and suggested that few offspring samples are needed to reject the null hypothesis of uniform offspring production. However, the sampled reproductive success distributions deviated significantly (χ(2) goodness-of-fit test p value reproductive success distribution at rates often >0.05 and as high as 0.24, even when hundreds of offspring were assigned parentage. In general, reproductive success patterns were less accurate when offspring were sampled from cohorts with larger numbers of parents and greater variance in reproductive success. Our model can be reparameterized with data from other species and will aid researchers in planning reproductive success studies by providing explicit sampling targets required to accurately assess reproductive success.

  19. Sampling on Quasicrystals

    OpenAIRE

    Grepstad, Sigrid

    2011-01-01

    We prove that quasicrystals are universal sets of stable sampling in any dimension. Necessary and sufficient density conditions for stable sampling and interpolation sets in one dimension are studied in detail.

  20. Preparation of solid-state samples of a transition metal coordination compound for synchrotron radiation photoemission studies

    CERN Document Server

    Crotti, C; Celestino, T; Fontana, S

    2003-01-01

    The aim of this research was to identify a sample preparation method suitable for the study of transition metal complexes by photoemission spectroscopy with synchrotron radiation as the X-ray source, even in the case where the compound is not evaporable. Solid-phase samples of W(CO) sub 4 (dppe) [dppe=1,2-bis(diphenylphosphino)ethane] were prepared according to different methods and their synchrotron radiation XPS spectra measured. The spectra acquired from samples prepared by spin coating show core level peaks only slightly broader than the spectrum recorded from UHV evaporated samples. Moreover, for these samples the reproducibility of the binding energy values is excellent. The dependence of the spin coating technique on parameters such as solvent and solution concentration, spinning speed and support material was studied. The same preparation method also allowed the acquisition of valence band spectra, the main peaks of which were clearly resolved. The results suggest that use of the spin coating techniqu...

  1. The Luna 16 and Luna 20 samples and their integrated studies in India

    International Nuclear Information System (INIS)

    Lal, D.

    1974-01-01

    The results of an integrated study of physical and chemical properties of lunar samples returned to earth by the automatic Soviet stations Luna 16 and 20 carried out with a view to dilineate the evolutionary history of moon, are reported. The nature of the Luna 16 and Luna 20 landing sites and lunar samples, and the manner in which the integrated analyses were planned and executed, are discussed. It is noted that the two lunar missions have provided a wealth of new information in unravelling the early history of planetary formation. (A.K.)

  2. Size Distributions and Characterization of Native and Ground Samples for Toxicology Studies

    Science.gov (United States)

    McKay, David S.; Cooper, Bonnie L.; Taylor, Larry A.

    2010-01-01

    This slide presentation shows charts and graphs that review the particle size distribution and characterization of natural and ground samples for toxicology studies. There are graphs which show the volume distribution versus the number distribution for natural occurring dust, jet mill ground dust, and ball mill ground dust.

  3. FREQUENCY OF ANEUPLOID SPERMATOZOA STUDIED BY MULTICOLOR FISH IN SERIAL SEMEN SAMPLES

    Science.gov (United States)

    Frequency of aneuploid spermatozoa studied by multicolor FISH in serial semen samplesM. Vozdova1, S. D. Perreault2, O. Rezacova1, D. Zudova1 , Z. Zudova3, S. G. Selevan4, J. Rubes1,51Veterinary Research Institute, Brno, Czech Republic; 2U.S. Environmental Protection A...

  4. Genotoxicity studies in semiconductor industry. 1. In vitro mutagenicity and genotoxicity studies of waste samples resulting from plasma etching

    Energy Technology Data Exchange (ETDEWEB)

    Braun, R.; Huettner, E.M.; Merten, H.; Raabe, F. (Institute of Plant Genetics and Crop Plant Research, Gatersleben (Germany))

    1993-07-01

    Solid waste samples taken from the etching reactor, the turbo pump, and the waste air system of a plasma etching technology line in semiconductor production were studied as to their genotoxic properties in a bacterial repair test, in the Ames/Salmonella microsome assay, in the SOS chromotest, in primary mouse hepatocytes, and in Chinese hamster V79 cell cultures. All three waste samples were found to be active by inducing of unscheduled DNA-synthesis in mouse hepatocytes in vitro. In the bacterial rec-type repair test with Proteus mirabilis, waste samples taken from the turbo pump and the vacuum pipe system were not genotoxic. The waste sample taken from the chlorine-mediated plasma reactor was clearly positive in the bacterial repair assay and in the SOS chromotest with Escherichia coli. Mutagenic activity was demonstrated for all samples in the presence and absence of S9 mix made from mouse liver homogenate. Again, highest mutagenic activity was recorded for the waste sample taken from the plasma reactor, while samples collected from the turbo pump and from the waste air system before dilution and liberation of the air were less mutagenic. For all samples chromosomal damage in V79 cells was not detected, indicating absence of clastogenic activity in vitro. Altogether, these results indicate generation of genotoxic and mutagenic products as a consequence of chlorine-mediated plasma etching in the microelectronics industry and the presence of genotoxins even in places distant from the plasma reactor. Occupational exposure can be expected both from the precipitated wastes and from chemicals reaching the environment with the air stream.

  5. 14C sample preparation for AMS microdosing studies at Lund University using online combustion and septa-sealed vials

    Science.gov (United States)

    Sydoff, Marie; Stenström, Kristina

    2010-04-01

    The Department of Physics at Lund University is participating in a European Union project called EUMAPP (European Union Microdose AMS Partnership Programme), in which sample preparation and accelerator mass spectrometry (AMS) measurements of biological samples from microdosing studies have been made. This paper describes a simplified method of converting biological samples to solid graphite for 14C analysis with AMS. The method is based on online combustion of the samples, and reduction of CO 2 in septa-sealed vials. The septa-sealed vials and disposable materials are used to eliminate sample cross-contamination. Measurements of ANU and Ox I standards show deviations of 2% and 3%, respectively, relative to reference values. This level of accuracy is sufficient for biological samples from microdosing studies. Since the method has very few handling steps from sample to graphite, the risk of failure during the sample preparation process is minimized, making the method easy to use in routine preparation of samples.

  6. 14C sample preparation for AMS microdosing studies at Lund University using online combustion and septa-sealed vials

    International Nuclear Information System (INIS)

    Sydoff, Marie; Stenstroem, Kristina

    2010-01-01

    The Department of Physics at Lund University is participating in a European Union project called EUMAPP (European Union Microdose AMS Partnership Programme), in which sample preparation and accelerator mass spectrometry (AMS) measurements of biological samples from microdosing studies have been made. This paper describes a simplified method of converting biological samples to solid graphite for 14 C analysis with AMS. The method is based on online combustion of the samples, and reduction of CO 2 in septa-sealed vials. The septa-sealed vials and disposable materials are used to eliminate sample cross-contamination. Measurements of ANU and Ox I standards show deviations of 2% and 3%, respectively, relative to reference values. This level of accuracy is sufficient for biological samples from microdosing studies. Since the method has very few handling steps from sample to graphite, the risk of failure during the sample preparation process is minimized, making the method easy to use in routine preparation of samples.

  7. Detection of multidrug-resistant tuberculosis from stored DNA Samples: A multicenter study

    OpenAIRE

    Marie Sylvianne Rabodoarivelo; A Brandao; M C Cergole Novella; A G C. Bombonatte; B Imperiale; N Rakotosamimanana; N Morcillo; V Rasolofo; J C Palomino; A Martin

    2018-01-01

    Background: In low-income countries, rapid detection of tuberculosis (TB) drug resistance is often restricted by the difficulties of transporting and storing sputum samples from remote health centers to the reference laboratories where molecular tests are available. The aim of this study was to evaluate the performance of four transport and storage systems for molecular detection of rifampicin (RIF) and isoniazid (INH) resistance. Methods: This was a multicenter study. Molecular detection of ...

  8. Preliminary study on element mass fraction determination on catfish samples from Paraguay

    International Nuclear Information System (INIS)

    Moreira, Edson G.; Catharino, Marilia G.M.; Vasconcellos, Marina B.A.; Frutos, Sixto A.; Insaurralde, Mario S.

    2013-01-01

    South American catfish (Pseudoplatystoma), commonly known in Spanish as atigrado or surubi and in Portuguese as surubim or pintado is a large fish that typically reaches 1 m long and weighs 60 kg to 80 kg and may be found at the basins of the Amazon, the Sao Francisco and de la Plata rivers, usually in riverbeds and deep wells. Being a much appreciated fish for human consumption, it is quite sought after by fishermen who have been contributing to the reduction of the stocks. This fact attracted the attention of the Paraguayan authorities to the point of imposing restrictions to free fishing and commercialization. This study aims to assist the conservation efforts towards this fish by investigating its exposure to possible pollutants. Preliminary results on element determination on six samples of catfish from Paraguayan rivers are presented. Cs, Co, Fe, Se and Zn were determined by applying an Instrumental Neutron Activation Analysis method. While these element levels were lower than the legislation for human consumption, the elements As, Cr e La were not detected in the samples as they are below the detection limit of the method employed. Atomic Absorption Spectrometry was used to investigate the presence of Cd, Hg and Pb in the samples. Hg was detected in the samples while Cd and Pb were below the detection limit of the method. (author)

  9. Preliminary study on element mass fraction determination on catfish samples from Paraguay

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Edson G.; Catharino, Marilia G.M.; Vasconcellos, Marina B.A., E-mail: emoreira@ipen.br, E-mail: mbvascon@ipen.br, E-mail: mariliasemmler@uol.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Frutos, Sixto A.; Insaurralde, Mario S., E-mail: tony8013@hotmail.com, E-mail: insaurraldemar9@hotmail.com [Universidad Nacional de Asuncion (FCV/UNA), San Lorenzo (Paraguay). Facultad de Ciencias Veterinarias. Departamento de Pesca y Acuicultura

    2013-07-01

    South American catfish (Pseudoplatystoma), commonly known in Spanish as atigrado or surubi and in Portuguese as surubim or pintado is a large fish that typically reaches 1 m long and weighs 60 kg to 80 kg and may be found at the basins of the Amazon, the Sao Francisco and de la Plata rivers, usually in riverbeds and deep wells. Being a much appreciated fish for human consumption, it is quite sought after by fishermen who have been contributing to the reduction of the stocks. This fact attracted the attention of the Paraguayan authorities to the point of imposing restrictions to free fishing and commercialization. This study aims to assist the conservation efforts towards this fish by investigating its exposure to possible pollutants. Preliminary results on element determination on six samples of catfish from Paraguayan rivers are presented. Cs, Co, Fe, Se and Zn were determined by applying an Instrumental Neutron Activation Analysis method. While these element levels were lower than the legislation for human consumption, the elements As, Cr e La were not detected in the samples as they are below the detection limit of the method employed. Atomic Absorption Spectrometry was used to investigate the presence of Cd, Hg and Pb in the samples. Hg was detected in the samples while Cd and Pb were below the detection limit of the method. (author)

  10. MicroRNA Expression in Laser Micro-dissected Breast Cancer Tissue Samples - a Pilot Study.

    Science.gov (United States)

    Seclaman, Edward; Narita, Diana; Anghel, Andrei; Cireap, Natalia; Ilina, Razvan; Sirbu, Ioan Ovidiu; Marian, Catalin

    2017-10-28

    Breast cancer continues to represent a significant public health burden despite outstanding research advances regarding the molecular mechanisms of cancer biology, biomarkers for diagnostics and prognostic and therapeutic management of this disease. The studies of micro RNAs in breast cancer have underlined their potential as biomarkers and therapeutic targets; however most of these studies are still done on largely heterogeneous whole breast tissue samples. In this pilot study we have investigated the expression of four micro RNAs (miR-21, 145, 155, 92) known to be involved in breast cancer, in homogenous cell populations collected by laser capture microdissection from breast tissue section slides. Micro RNA expression was assessed by real time PCR, and associations with clinical and pathological characteristics were also explored. Our results have confirmed previous associations of miR-21 expression with poor prognosis characteristics of breast cancers such as high stage, large and highly proliferative tumors. No statistically significant associations were found with the other micro RNAs investigated, possibly due to the small sample size of our study. Our results also suggest that miR-484 could be a suitable endogenous control for data normalization in breast tissues, these results needing further confirmation by future studies. In summary, our pilot study showed the feasibility of detecting micro RNAs expression in homogenous laser captured microdissected invasive breast cancer samples, and confirmed some of the previously reported associations with poor prognostic characteristics of breast tumors.

  11. Analysis of small sample size studies using nonparametric bootstrap test with pooled resampling method.

    Science.gov (United States)

    Dwivedi, Alok Kumar; Mallawaarachchi, Indika; Alvarado, Luis A

    2017-06-30

    Experimental studies in biomedical research frequently pose analytical problems related to small sample size. In such studies, there are conflicting findings regarding the choice of parametric and nonparametric analysis, especially with non-normal data. In such instances, some methodologists questioned the validity of parametric tests and suggested nonparametric tests. In contrast, other methodologists found nonparametric tests to be too conservative and less powerful and thus preferred using parametric tests. Some researchers have recommended using a bootstrap test; however, this method also has small sample size limitation. We used a pooled method in nonparametric bootstrap test that may overcome the problem related with small samples in hypothesis testing. The present study compared nonparametric bootstrap test with pooled resampling method corresponding to parametric, nonparametric, and permutation tests through extensive simulations under various conditions and using real data examples. The nonparametric pooled bootstrap t-test provided equal or greater power for comparing two means as compared with unpaired t-test, Welch t-test, Wilcoxon rank sum test, and permutation test while maintaining type I error probability for any conditions except for Cauchy and extreme variable lognormal distributions. In such cases, we suggest using an exact Wilcoxon rank sum test. Nonparametric bootstrap paired t-test also provided better performance than other alternatives. Nonparametric bootstrap test provided benefit over exact Kruskal-Wallis test. We suggest using nonparametric bootstrap test with pooled resampling method for comparing paired or unpaired means and for validating the one way analysis of variance test results for non-normal data in small sample size studies. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  12. A novel approach for small sample size family-based association studies: sequential tests.

    Science.gov (United States)

    Ilk, Ozlem; Rajabli, Farid; Dungul, Dilay Ciglidag; Ozdag, Hilal; Ilk, Hakki Gokhan

    2011-08-01

    In this paper, we propose a sequential probability ratio test (SPRT) to overcome the problem of limited samples in studies related to complex genetic diseases. The results of this novel approach are compared with the ones obtained from the traditional transmission disequilibrium test (TDT) on simulated data. Although TDT classifies single-nucleotide polymorphisms (SNPs) to only two groups (SNPs associated with the disease and the others), SPRT has the flexibility of assigning SNPs to a third group, that is, those for which we do not have enough evidence and should keep sampling. It is shown that SPRT results in smaller ratios of false positives and negatives, as well as better accuracy and sensitivity values for classifying SNPs when compared with TDT. By using SPRT, data with small sample size become usable for an accurate association analysis.

  13. Large Sample Neutron Activation Analysis of Heterogeneous Samples

    International Nuclear Information System (INIS)

    Stamatelatos, I.E.; Vasilopoulou, T.; Tzika, F.

    2018-01-01

    A Large Sample Neutron Activation Analysis (LSNAA) technique was developed for non-destructive analysis of heterogeneous bulk samples. The technique incorporated collimated scanning and combining experimental measurements and Monte Carlo simulations for the identification of inhomogeneities in large volume samples and the correction of their effect on the interpretation of gamma-spectrometry data. Corrections were applied for the effect of neutron self-shielding, gamma-ray attenuation, geometrical factor and heterogeneous activity distribution within the sample. A benchmark experiment was performed to investigate the effect of heterogeneity on the accuracy of LSNAA. Moreover, a ceramic vase was analyzed as a whole demonstrating the feasibility of the technique. The LSNAA results were compared against results obtained by INAA and a satisfactory agreement between the two methods was observed. This study showed that LSNAA is a technique capable to perform accurate non-destructive, multi-elemental compositional analysis of heterogeneous objects. It also revealed the great potential of the technique for the analysis of precious objects and artefacts that need to be preserved intact and cannot be damaged for sampling purposes. (author)

  14. Social Anhedonia and Schizotypy in a Community Sample: The Maryland Longitudinal Study of Schizotypy

    Science.gov (United States)

    Blanchard, Jack J.; Collins, Lindsay M.; Aghevli, Minu; Leung, Winnie W.; Cohen, Alex S.

    2011-01-01

    Social anhedonia has been employed in psychometric high-risk studies to identify putative schizotypes. To date, this research has focused almost exclusively on college samples. The current study sought to examine the validity of social anhedonia as an indicator of risk for schizophrenia-spectrum disorders within a community sample. Furthermore, we evaluated the role of other individual difference variables in accounting for variable clinical severity within the social anhedonia group including trait affectivity, social support, and family environment. Following the mailed questionnaire screening of 2434 eighteen-year olds, laboratory assessments were conducted with individuals identified as being high in social anhedonia (n = 86) and a comparison sample (n = 89). Compared with the control group, individuals in the social anhedonia group were found to have higher rates of mood disorders, elevated schizophrenia-spectrum personality disorder characteristics, greater negative symptom characteristics, and lower global functioning. Individuals within the social anhedonia group also reported greater trait negative affectivity, lower positive affectivity, less social support, and more family conflict. Low social support and problematic family environment were found to be related to elevations in spectrum personality disorder characteristics and poorer functioning within the social anhedonia group. These cross-sectional findings from a community sample provide further support for social anhedonia as a possible indicator of schizotypy. PMID:19850669

  15. Cooling tower wood sampling and analyses: A case study

    International Nuclear Information System (INIS)

    Haymore, J.L.

    1985-01-01

    Extensive wood sampling and analyses programs were initiated on crossflow and counterflow cooling towers that have been in service since 1951 and 1955, respectively. Wood samples were taken from all areas of the towers and were subjected to biological, chemical and physical tests. The tests and results for the analyses are discussed. The results indicate the degree of wood deterioration, and areas of the towers which experience the most advanced degree of degradation

  16. A Preliminary Study on Sensitivity and Uncertainty Analysis with Statistic Method: Uncertainty Analysis with Cross Section Sampling from Lognormal Distribution

    Energy Technology Data Exchange (ETDEWEB)

    Song, Myung Sub; Kim, Song Hyun; Kim, Jong Kyung [Hanyang Univ., Seoul (Korea, Republic of); Noh, Jae Man [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The uncertainty evaluation with statistical method is performed by repetition of transport calculation with sampling the directly perturbed nuclear data. Hence, the reliable uncertainty result can be obtained by analyzing the results of the numerous transport calculations. One of the problems in the uncertainty analysis with the statistical approach is known as that the cross section sampling from the normal (Gaussian) distribution with relatively large standard deviation leads to the sampling error of the cross sections such as the sampling of the negative cross section. Some collection methods are noted; however, the methods can distort the distribution of the sampled cross sections. In this study, a sampling method of the nuclear data is proposed by using lognormal distribution. After that, the criticality calculations with sampled nuclear data are performed and the results are compared with that from the normal distribution which is conventionally used in the previous studies. In this study, the statistical sampling method of the cross section with the lognormal distribution was proposed to increase the sampling accuracy without negative sampling error. Also, a stochastic cross section sampling and writing program was developed. For the sensitivity and uncertainty analysis, the cross section sampling was pursued with the normal and lognormal distribution. The uncertainties, which are caused by covariance of (n,.) cross sections, were evaluated by solving GODIVA problem. The results show that the sampling method with lognormal distribution can efficiently solve the negative sampling problem referred in the previous studies. It is expected that this study will contribute to increase the accuracy of the sampling-based uncertainty analysis.

  17. A Preliminary Study on Sensitivity and Uncertainty Analysis with Statistic Method: Uncertainty Analysis with Cross Section Sampling from Lognormal Distribution

    International Nuclear Information System (INIS)

    Song, Myung Sub; Kim, Song Hyun; Kim, Jong Kyung; Noh, Jae Man

    2013-01-01

    The uncertainty evaluation with statistical method is performed by repetition of transport calculation with sampling the directly perturbed nuclear data. Hence, the reliable uncertainty result can be obtained by analyzing the results of the numerous transport calculations. One of the problems in the uncertainty analysis with the statistical approach is known as that the cross section sampling from the normal (Gaussian) distribution with relatively large standard deviation leads to the sampling error of the cross sections such as the sampling of the negative cross section. Some collection methods are noted; however, the methods can distort the distribution of the sampled cross sections. In this study, a sampling method of the nuclear data is proposed by using lognormal distribution. After that, the criticality calculations with sampled nuclear data are performed and the results are compared with that from the normal distribution which is conventionally used in the previous studies. In this study, the statistical sampling method of the cross section with the lognormal distribution was proposed to increase the sampling accuracy without negative sampling error. Also, a stochastic cross section sampling and writing program was developed. For the sensitivity and uncertainty analysis, the cross section sampling was pursued with the normal and lognormal distribution. The uncertainties, which are caused by covariance of (n,.) cross sections, were evaluated by solving GODIVA problem. The results show that the sampling method with lognormal distribution can efficiently solve the negative sampling problem referred in the previous studies. It is expected that this study will contribute to increase the accuracy of the sampling-based uncertainty analysis

  18. Accuracy of micro four-point probe measurements on inhomogeneous samples: A probe spacing dependence study

    DEFF Research Database (Denmark)

    Wang, Fei; Petersen, Dirch Hjorth; Østerberg, Frederik Westergaard

    2009-01-01

    In this paper, we discuss a probe spacing dependence study in order to estimate the accuracy of micro four-point probe measurements on inhomogeneous samples. Based on sensitivity calculations, both sheet resistance and Hall effect measurements are studied for samples (e.g. laser annealed samples...... the probe spacing is smaller than 1/40 of the variation wavelength, micro four-point probes can provide an accurate record of local properties with less than 1% measurement error. All the calculations agree well with previous experimental results.......) with periodic variations of sheet resistance, sheet carrier density, and carrier mobility. With a variation wavelength of ¿, probe spacings from 0.0012 to 1002 have been applied to characterize the local variations. The calculations show that the measurement error is highly dependent on the probe spacing. When...

  19. Study of Efficiency Calibrations of HPGe Detectors for Radioactivity Measurements of Environmental Samples

    International Nuclear Information System (INIS)

    Harb, S.; Salahel Din, K.; Abbady, A.

    2009-01-01

    In this paper, we describe a method of calibrating of efficiency of a HPGe gamma-ray spectrometry of bulk environmental samples (Tea, crops, water, and soil) is a significant part of the environmental radioactivity measurements. Here we will discuss the full energy peak efficiency (FEPE) of three HPGe detectors it as a consequence, it is essential that the efficiency is determined for each set-up employed. Besides to take full advantage at gamma-ray spectrometry, a set of efficiency at several energies which covers the wide the range in energy, the large the number of radionuclides whose concentration can be determined to measure the main natural gamma-ray emitters, the efficiency should be known at least from 46.54 keV ( 210 Pb) to 1836 keV ( 88 Y). Radioactive sources were prepared from two different standards, a first mixed standard QC Y 40 containing 210 Pb, 241 Am, 109 Cd, and Co 57 , and the second QC Y 48 containing 241 Am, 109 Cd, 57 Co, 139 Ce, 113 Sn, 85 Sr, 137 Cs, 88 Y, and 60 Co is necessary in order to calculate the activity of the different radionuclides contained in a sample. In this work, we will study the efficiency calibration as a function of different parameters as:- Energy of gamma ray from 46.54 keV ( 210 Pb) to 1836 keV ( 88 Y), three different detectors A, B, and C, geometry of containers (point source, marinelli beaker, and cylindrical bottle 1 L), height of standard soil samples in bottle 250 ml, and density of standard environmental samples. These standard environmental sample must be measured before added standard solution because we will use the same environmental samples in order to consider the self absorption especially and composition in the case of volume samples.

  20. The study of chemical forms of mercury in human hair and other bio-environmental samples

    International Nuclear Information System (INIS)

    Kratzer, K.; Benes, P.

    1995-01-01

    The results of the continued studies on methods of analysis for forms of mercury in hair, and of the distribution of mercury among inorganic and organic forms in human hair are described. A new method for determining methylmercury has been developed, based on the selective leaching of methylmercury from hair using 2M hydrochioric acid. This method was used, in combination with the determination of mercury by atomic absorption spectrometry, for the analysis of mercury forms in three samples of human hair and two samples of fish homogenate. Good reproducibility of parallel determinations was obtained. The results were compared with literature data for the samples, or with the results of the analysis of the same samples by extraction method described earlier. Good agreement was also found between these methods. Further experiments were concerned with the study of the effect of radiation sterilization on the forms of mercury in hair, of the speciation of 203 Hg formed by irradiation of hair in nuclear reactor and with the labelling of a large batch of human hair with methylmercury. (author)

  1. Experimental Investigation Of Microbially Induced Corrosion Of Test Samples And Effect Of Self-assembled Hydrophobic Monolayers. Exposure Of Test Samples To Continuous Microbial Cultures, Chemical Analysis, And Biochemical Studies

    CERN Document Server

    Laurinavichius, K S

    1998-01-01

    Experimental Investigation Of Microbially Induced Corrosion Of Test Samples And Effect Of Self-assembled Hydrophobic Monolayers. Exposure Of Test Samples To Continuous Microbial Cultures, Chemical Analysis, And Biochemical Studies

  2. Applicability of Non-Invasive Sampling in Population Genetic Study of Taiwanese Macaques (Macaca cyclopis

    Directory of Open Access Journals (Sweden)

    Jui-Hua Chu

    2006-12-01

    Full Text Available This paper presents a pilot study conducted to test the applicability of non-invasive sampling approach in population genetic studies of Taiwanese macaques (Macaca cyclopis. Monkey feces were collected in the field and used as non-invasive DNA sources. PCR success rates of both microsatellite and mitochondrial DNA markers were examined. When compared with other studies by non-invasive genetic sampling of different mammal species, success rate of microsatellite PCR amplification is low (42.4%, N = 181 while that of mtDNA PCR amplification is acceptable (66.5%, N = 334. The low PCR success rate and poor PCR repeatability of microsatellite alleles due to allelic dropout and false alleles make it difficult to obtain a reliable microsatellite data set. However, the difficulties may be overcome by new techniques.

  3. Experimental study of UC polycrystals in the prospect of improving the as-fabricated sample purity

    Energy Technology Data Exchange (ETDEWEB)

    Raveu, Gaëlle, E-mail: gaelle.raveu@cea.fr [CEA, DEC, 13108 Saint-Paul-Lez-Durance (France); Martin, Guillaume; Fiquet, Olivier; Garcia, Philippe; Carlot, Gaëlle; Palancher, Hervé [CEA, DEC, 13108 Saint-Paul-Lez-Durance (France); Bonnin, Anne [ESRF, 6, rue J. Horowitz, 38500 Grenoble Cedex (France); Khodja, Hicham [CEA, DEC, 13108 Saint-Paul-Lez-Durance (France); Raepsaet, Caroline [CEA, IRAMIS, LEEL, 91191 Gif-Sur-Yvette (France); Sauvage, Thierry; Barthe, Marie-France [CNRS – CEMHTI, 3a Rue de la Férolerie, 45071 Orleans (France)

    2014-12-15

    Uranium and plutonium carbides are candidate fuels for Generation IV nuclear reactors. This study is focused on the characterization of uranium monocarbide samples. The successive fabrication steps were carried out under atmospheres containing low oxygen and moisture concentrations (typically less than 100 ppm) but sample transfers occurred in air. Six samples were sliced from four pellets elaborated by carbothermic reaction under vacuum. Little presence of UC{sub 2} is expected in these samples. The α-UC{sub 2} phase was indeed detected within one of these UC samples during an XRD experiment performed with synchrotron radiation. Moreover, oxygen content at the surface of these samples was depth profiled using a recently developed nuclear reaction analysis method. Large oxygen concentrations were measured in the first micron below the sample surface and particularly in the first 100–150 nm. UC{sub 2} inclusions were found to be more oxidized than the surrounding matrix. This work points out to the fact that more care must be given at each step of UC fabrication since the material readily reacts with oxygen and moisture. A new glovebox facility using a highly purified atmosphere is currently being built in order to obtain single phase UC samples of better purity.

  4. Positron annihilation lifetime study of positive temperature coefficient BaTiO3 samples

    International Nuclear Information System (INIS)

    Ling Chen; Mingkang Teng; Guanghou Wang; Xiaoyun Li; Tianchang Lu

    1989-01-01

    In order to investigate the doped vacancies in BaTiO 3 samples as well as their influence on the positive temperature coefficient (PTC) the positron annihilation lifetime spectroscopy was applied. Two groups of BaTiO 3 samples with BaO excess were prepared by doping different concentrations of La 2 O 3 and Nb 2 O 5 , respectively in the range from 0.1 to 3 at%. A third group of samples of two Sb-doped PTC BaTiO 3 semiconductors with excess BaO or TiO 2 were studied by the aid of positron technique before and after being reduced. It is shown that the positron lifetime parameters are sensitive to changes in the vacancy concentration in BaTiO 3 ceramics near the 0.1 mol% region. But they are almost unchanged during reduction processing; the resistivity of samples changed by one to two orders of magnitude through the reduction. It can be concluded that the PTC effect is due to oxygen on the grain boundary rather than vacancies, and that the Heywang-Jonker model is more reasonable

  5. Study on a new meteorological sampling scheme developed for the OSCAAR code system

    International Nuclear Information System (INIS)

    Liu Xinhe; Tomita, Kenichi; Homma, Toshimitsu

    2002-03-01

    One important step in Level-3 Probabilistic Safety Assessment is meteorological sequence sampling, on which the previous studies were mainly related to code systems using the straight-line plume model and more efforts are needed for those using the trajectory puff model such as the OSCAAR code system. This report describes the development of a new meteorological sampling scheme for the OSCAAR code system that explicitly considers population distribution. A group of principles set for the development of this new sampling scheme includes completeness, appropriate stratification, optimum allocation, practicability and so on. In this report, discussions are made about the procedures of the new sampling scheme and its application. The calculation results illustrate that although it is quite difficult to optimize stratification of meteorological sequences based on a few environmental parameters the new scheme do gather the most inverse conditions in a single subset of meteorological sequences. The size of this subset may be as small as a few dozens, so that the tail of a complementary cumulative distribution function is possible to remain relatively static in different trials of the probabilistic consequence assessment code. (author)

  6. A shared frailty model for case-cohort samples: parent and offspring relations in an adoption study

    DEFF Research Database (Denmark)

    Petersen, Liselotte; Sørensen, Thorkild I A; Andersen, Per Kragh

    2010-01-01

    of their biological and adoptive parents were collected with the purpose of studying the association of survival between the adoptee and his/her biological or adoptive parents. Motivated by this study, we explored how to make inference in a shared frailty model for case-cohort data. Our approach was to use inverse......The Danish adoption register contains data on the 12 301 Danish nonfamilial adoptions during 1924-1947. From that register a case-cohort sample was selected consisting of all case adoptees, that is those adoptees dying before age 70 years, and a random sample of 1683 adoptees. The survival data...... probability weighting to account for the sampling in a conditional, shared frailty Poisson model and to use the robust variance estimator proposed by Moger et al. (Statist. Med. 2008; 27:1062-1074).To explore the performance of the estimation procedure, a simulation study was conducted. We studied situations...

  7. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-06-22

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.

  8. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D’Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-01-01

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations. PMID:28640202

  9. Study on methods of quantitative analysis of the biological thin samples in EM X-ray microanalysis

    International Nuclear Information System (INIS)

    Zhang Detian; Zhang Xuemin; He Kun; Yang Yi; Zhang Sa; Wang Baozhen

    2000-01-01

    Objective: To study the methods of quantitative analysis of the biological thin samples. Methods: Hall theory was used to study the qualitative analysis, background subtraction, peel off overlap peaks; external radiation and aberrance of spectra. Results: The results of reliable qualitative analysis and precise quantitative analysis were achieved. Conclusion: The methods for analysis of the biological thin samples in EM X-ray microanalysis can be used in biomedical research

  10. A comparative study of sampling techniques for monitoring carcass contamination

    NARCIS (Netherlands)

    Snijders, J.M.A.; Janssen, M.H.W.; Gerats, G.E.; Corstiaensen, G.P.

    1984-01-01

    Four bacteriological sampling techniques i.e. the excision, double swab, agar contract and modified agar contact techniques were compared by sampling pig carcasses before and after chilling. As well as assessing the advantages and disadvantages of the techniques particular attention was paid to

  11. Study on a pattern classification method of soil quality based on simplified learning sample dataset

    Science.gov (United States)

    Zhang, Jiahua; Liu, S.; Hu, Y.; Tian, Y.

    2011-01-01

    Based on the massive soil information in current soil quality grade evaluation, this paper constructed an intelligent classification approach of soil quality grade depending on classical sampling techniques and disordered multiclassification Logistic regression model. As a case study to determine the learning sample capacity under certain confidence level and estimation accuracy, and use c-means algorithm to automatically extract the simplified learning sample dataset from the cultivated soil quality grade evaluation database for the study area, Long chuan county in Guangdong province, a disordered Logistic classifier model was then built and the calculation analysis steps of soil quality grade intelligent classification were given. The result indicated that the soil quality grade can be effectively learned and predicted by the extracted simplified dataset through this method, which changed the traditional method for soil quality grade evaluation. ?? 2011 IEEE.

  12. Genesis Solar Wind Collector Cleaning Assessment: Update on 60336 Sample Case Study

    Science.gov (United States)

    Goreva, Y. S.; Allums, K. K.; Gonzalez, C. P.; Jurewicz, A. J.; Burnett, D. S.; Allton, J. H.; Kuhlman, K. R.; Woolum, D.

    2015-01-01

    To maximize the scientific return of Genesis Solar Wind return mission it is necessary to characterize and remove a crash-derived particle and thin film surface contamination. A small subset of Genesis mission collector fragments are being subjected to extensive study via various techniques. Here we present an update on the sample 60336, a Czochralski silicon (Si-CZ) based wafer from the bulk array (B/C). This sample has undergone multiple cleaning steps (see the table below): UPW spin wash, aggressive chemical cleanings (including aqua regia, hot xylene and RCA1), as well as optical and chemical (EDS, ToF-SIMS) imaging. Contamination appeared on the surface of 60336 after the initial 2007 UPW cleaning. Aqua regia and hot xylene treatment (8/13/2013) did little to remove contaminants. The sample was UPW cleaned for the third time and imaged (9/16/13). The UPW removed the dark stains that were visible on the sample. However, some features, like "the Flounder" (a large, 100 micron feature in Fig. 1b) appeared largely intact, resisting all previous cleaning efforts. These features were likely from mobilized adhesive, derived from the Post-It notes used to stabilize samples for transport from Utah after the hard landing. To remove this contamination, an RCA step 1 organic cleaning (RCA1) was employed. Although we are still uncertain on the nature of the Flounder and why it is resistant to UPW and aqua regia/hot xylene treatment, we have found RCA1 to be suitable for its removal. It is likely that the glue from sticky pads used during collector recovery may have been a source for resistant organic contamination [9]; however [8] shows that UPW reaction with crash-derived organic contamination does not make particle removal more difficult.

  13. Economic and Humanistic Burden of Osteoarthritis: A Systematic Review of Large Sample Studies.

    Science.gov (United States)

    Xie, Feng; Kovic, Bruno; Jin, Xuejing; He, Xiaoning; Wang, Mengxiao; Silvestre, Camila

    2016-11-01

    Osteoarthritis (OA) consumes a significant amount of healthcare resources, and impairs the health-related quality of life (HRQoL) of patients. Previous reviews have consistently found substantial variations in the costs of OA across studies and countries. The comparability between studies was poor and limited the detection of the true differences between these studies. To review large sample studies on measuring the economic and/or humanistic burden of OA published since May 2006. We searched MEDLINE and EMBASE databases using comprehensive search strategies to identify studies reporting economic burden and HRQoL of OA. We included large sample studies if they had a sample size ≥1000 and measured the cost and/or HRQoL of OA. Reviewers worked independently and in duplicate, performing a cross-check between groups to verify agreement. Within- and between-group consolidation was performed to resolve discrepancies, with outstanding discrepancies being resolved by an arbitrator. The Kappa statistic was reported to assess the agreement between the reviewers. All costs were adjusted in their original currency to year 2015 using published inflation rates for the country where the study was conducted, and then converted to 2015 US dollars. A total of 651 articles were screened by title and abstract, 94 were reviewed in full text, and 28 were included in the final review. The Kappa value was 0.794. Twenty studies reported direct costs and nine reported indirect costs. The total annual average direct costs varied from US$1442 to US$21,335, both in USA. The annual average indirect costs ranged from US$238 to US$29,935. Twelve studies measured HRQoL using various instruments. The Short Form 12 version 2 scores ranged from 35.0 to 51.3 for the physical component, and from 43.5 to 55.0 for the mental component. Health utilities varied from 0.30 for severe OA to 0.77 for mild OA. Per-patient OA costs are considerable and a patient's quality of life remains poor. Variations in

  14. Enhancing sampling design in mist-net bat surveys by accounting for sample size optimization

    OpenAIRE

    Trevelin, Leonardo Carreira; Novaes, Roberto Leonan Morim; Colas-Rosas, Paul François; Benathar, Thayse Cristhina Melo; Peres, Carlos A.

    2017-01-01

    The advantages of mist-netting, the main technique used in Neotropical bat community studies to date, include logistical implementation, standardization and sampling representativeness. Nonetheless, study designs still have to deal with issues of detectability related to how different species behave and use the environment. Yet there is considerable sampling heterogeneity across available studies in the literature. Here, we approach the problem of sample size optimization. We evaluated the co...

  15. Flow cytometry for feline lymphoma: a retrospective study regarding pre-analytical factors possibly affecting the quality of samples.

    Science.gov (United States)

    Martini, Valeria; Bernardi, Serena; Marelli, Priscilla; Cozzi, Marzia; Comazzi, Stefano

    2018-06-01

    Objectives Flow cytometry (FC) is becoming increasingly popular among veterinary oncologists for the diagnosis of lymphoma or leukaemia. It is accurate, fast and minimally invasive. Several studies of FC have been carried out in canine oncology and applied with great results, whereas there is limited knowledge and use of this technique in feline patients. This is mainly owing to the high prevalence of intra-abdominal lymphomas in this species and the difficulty associated with the diagnostic procedures needed to collect the sample. The purpose of the present study is to investigate whether any pre-analytical factor might affect the quality of suspected feline lymphoma samples for FC analysis. Methods Ninety-seven consecutive samples of suspected feline lymphoma were retrospectively selected from the authors' institution's FC database. The referring veterinarians were contacted and interviewed about several different variables, including signalment, appearance of the lesion, features of the sampling procedure and the experience of veterinarians performing the sampling. Statistical analyses were performed to assess the possible influence of these variables on the cellularity of the samples and the likelihood of it being finally processed for FC. Results Sample cellularity is a major factor in the likelihood of the sample being processed. Moreover, sample cellularity was significantly influenced by the needle size, with 21 G needles providing the highest cellularity. Notably, the sample cellularity and the likelihood of being processed did not vary between peripheral and intra-abdominal lesions. Approximately half of the cats required pharmacological restraint. Side effects were reported in one case only (transient swelling after peripheral lymph node sampling). Conclusions and relevance FC can be safely applied to cases of suspected feline lymphomas, including intra-abdominal lesions. A 21 G needle should be preferred for sampling. This study provides the basis for

  16. Bright environmental light ameliorates deficient subjective liking in insomnia : an experience sampling study

    NARCIS (Netherlands)

    Te Lindert, Bart H W; Itzhacki, Jacob; van der Meijden, Wisse P; Kringelbach, Morten L; Mendoza, Jorge; Van Someren, Eus J W

    2018-01-01

    Study Objectives: Altered comfort sensing and reduced gray matter volume in the orbitofrontal cortex of the brain in people suffering from Insomnia Disorder (ID) suggest compromised processes of motivation and hedonia. The Experience Sampling (ES) method was used to evaluate whether, in naturalistic

  17. Fear, Anger, and Risk Preference Reversals: An Experimental Study on a Chinese Sample.

    Science.gov (United States)

    She, Shengxiang; Eimontaite, Iveta; Zhang, Dangli; Sun, Yan

    2017-01-01

    Fear and anger are basic emotions of the same valence which differ in terms of their certainty and control dimensions according to the Appraisal Tendency Framework, a theory addressing the relationship between specific emotions, and judgments and choices. Past research based on the Appraisal Theory revealed contradictory results for risky choice decision-making. However, these conclusions were drawn from Western samples (e.g., North American). Considering potential cultural differences, the present study aims to investigate whether the Appraisal Tendency hypothesis yields the same results in a Chinese sample. Our first study explores how dispositional fear and anger influence risk preferences through a classic virtual "Asia Disease Problem" task and the second study investigates how induced fear and anger influence risk preferences through an incentive-compatible task. Consistent with previous research, our results reveal that induced fear and anger have differential effects on risky decisions: angry participants prefer the risk-seeking option, whereas fearful participants prefer a risk-averse option. However, we find no associations between dispositional fear (or anger) and risky decisions.

  18. Fear, Anger, and Risk Preference Reversals: An Experimental Study on a Chinese Sample

    Directory of Open Access Journals (Sweden)

    Shengxiang She

    2017-08-01

    Full Text Available Fear and anger are basic emotions of the same valence which differ in terms of their certainty and control dimensions according to the Appraisal Tendency Framework, a theory addressing the relationship between specific emotions, and judgments and choices. Past research based on the Appraisal Theory revealed contradictory results for risky choice decision-making. However, these conclusions were drawn from Western samples (e.g., North American. Considering potential cultural differences, the present study aims to investigate whether the Appraisal Tendency hypothesis yields the same results in a Chinese sample. Our first study explores how dispositional fear and anger influence risk preferences through a classic virtual “Asia Disease Problem” task and the second study investigates how induced fear and anger influence risk preferences through an incentive-compatible task. Consistent with previous research, our results reveal that induced fear and anger have differential effects on risky decisions: angry participants prefer the risk-seeking option, whereas fearful participants prefer a risk-averse option. However, we find no associations between dispositional fear (or anger and risky decisions.

  19. Study of radioactivity levels in detergent powders samples by gamma spectroscopy

    Directory of Open Access Journals (Sweden)

    Ali A. Abojassim

    2014-10-01

    Full Text Available This study focuses on the evaluation of the natural radioactivity levels in ten samples of the detergent powders that available in Iraqi markets. We have determined the specific activities of uranium, thorium and potassium using gamma spectroscopy and calculation of radiation hazard indices. The results of the activities of radionuclides (238U, 232Th, 40K for detergent powders samples, are found that the 238U specific activities were varied from (11.489 ± 2.089 Bq/kg to (36.062 ± 2.478 Bq/kg, while the 232th specific activities were varied from (1.411 ± 0.609 Bq/kg to (9.272 ± 1.642 Bq/kg and 40K were varied from (8.189 ± 2.339 Bq/kg to (91.888 ± 4.164 Bq/kg. These values are always lower than those of raw materials, what is explained by the conservation of radioactive material throughout the manufacturing process. The radium equivalent activity Raeq, the external hazard index Hex and the internal hazard index Hin dose due to natural radioactivity estimated below the regulatory standard recommended which are (370 Bq/kg, 1 and 1 according to OECD 1979 and ICRP 2000, allows us to show that Detergent powders samples products are not contaminated by radioactivity, are healthy and do not have harmful radiological impact on the consumer.

  20. Studies on the true coincidence correction in measuring filter samples by gamma spectrometry

    CERN Document Server

    Lian Qi; Chang Yong Fu; Xia Bing

    2002-01-01

    The true coincidence correction in measuring filter samples has been studied by high efficiency HPGe gamma detectors. The true coincidence correction for a specific three excited levels de-excitation case has been analyzed, and the typical analytical expressions of true coincidence correction factors have been given. According to the measured relative efficiency on the detector surface with 8 'single' energy gamma emitters and efficiency of filter samples, the peak and total efficiency surfaces are fitted. The true coincidence correction factors of sup 6 sup 0 Co and sup 1 sup 5 sup 2 Eu calculated by the efficiency surfaces agree well with experimental results

  1. The problem of large samples. An activation analysis study of electronic waste material

    International Nuclear Information System (INIS)

    Segebade, C.; Goerner, W.; Bode, P.

    2007-01-01

    Large-volume instrumental photon activation analysis (IPAA) was used for the investigation of shredded electronic waste material. Sample masses from 1 to 150 grams were analyzed to obtain an estimate of the minimum sample size to be taken to achieve a representativeness of the results which is satisfactory for a defined investigation task. Furthermore, the influence of irradiation and measurement parameters upon the quality of the analytical results were studied. Finally, the analytical data obtained from IPAA and instrumental neutron activation analysis (INAA), both carried out in a large-volume mode, were compared. Only parts of the values were found in satisfactory agreement. (author)

  2. Methodology Series Module 5: Sampling Strategies.

    Science.gov (United States)

    Setia, Maninder Singh

    2016-01-01

    Once the research question and the research design have been finalised, it is important to select the appropriate sample for the study. The method by which the researcher selects the sample is the ' Sampling Method'. There are essentially two types of sampling methods: 1) probability sampling - based on chance events (such as random numbers, flipping a coin etc.); and 2) non-probability sampling - based on researcher's choice, population that accessible & available. Some of the non-probability sampling methods are: purposive sampling, convenience sampling, or quota sampling. Random sampling method (such as simple random sample or stratified random sample) is a form of probability sampling. It is important to understand the different sampling methods used in clinical studies and mention this method clearly in the manuscript. The researcher should not misrepresent the sampling method in the manuscript (such as using the term ' random sample' when the researcher has used convenience sample). The sampling method will depend on the research question. For instance, the researcher may want to understand an issue in greater detail for one particular population rather than worry about the ' generalizability' of these results. In such a scenario, the researcher may want to use ' purposive sampling' for the study.

  3. Methodology series module 5: Sampling strategies

    Directory of Open Access Journals (Sweden)

    Maninder Singh Setia

    2016-01-01

    Full Text Available Once the research question and the research design have been finalised, it is important to select the appropriate sample for the study. The method by which the researcher selects the sample is the 'Sampling Method'. There are essentially two types of sampling methods: 1 probability sampling – based on chance events (such as random numbers, flipping a coin etc.; and 2 non-probability sampling – based on researcher's choice, population that accessible & available. Some of the non-probability sampling methods are: purposive sampling, convenience sampling, or quota sampling. Random sampling method (such as simple random sample or stratified random sample is a form of probability sampling. It is important to understand the different sampling methods used in clinical studies and mention this method clearly in the manuscript. The researcher should not misrepresent the sampling method in the manuscript (such as using the term 'random sample' when the researcher has used convenience sample. The sampling method will depend on the research question. For instance, the researcher may want to understand an issue in greater detail for one particular population rather than worry about the 'generalizability' of these results. In such a scenario, the researcher may want to use 'purposive sampling' for the study.

  4. Power and sample-size estimation for microbiome studies using pairwise distances and PERMANOVA.

    Science.gov (United States)

    Kelly, Brendan J; Gross, Robert; Bittinger, Kyle; Sherrill-Mix, Scott; Lewis, James D; Collman, Ronald G; Bushman, Frederic D; Li, Hongzhe

    2015-08-01

    The variation in community composition between microbiome samples, termed beta diversity, can be measured by pairwise distance based on either presence-absence or quantitative species abundance data. PERMANOVA, a permutation-based extension of multivariate analysis of variance to a matrix of pairwise distances, partitions within-group and between-group distances to permit assessment of the effect of an exposure or intervention (grouping factor) upon the sampled microbiome. Within-group distance and exposure/intervention effect size must be accurately modeled to estimate statistical power for a microbiome study that will be analyzed with pairwise distances and PERMANOVA. We present a framework for PERMANOVA power estimation tailored to marker-gene microbiome studies that will be analyzed by pairwise distances, which includes: (i) a novel method for distance matrix simulation that permits modeling of within-group pairwise distances according to pre-specified population parameters; (ii) a method to incorporate effects of different sizes within the simulated distance matrix; (iii) a simulation-based method for estimating PERMANOVA power from simulated distance matrices; and (iv) an R statistical software package that implements the above. Matrices of pairwise distances can be efficiently simulated to satisfy the triangle inequality and incorporate group-level effects, which are quantified by the adjusted coefficient of determination, omega-squared (ω2). From simulated distance matrices, available PERMANOVA power or necessary sample size can be estimated for a planned microbiome study. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  5. On sample size of the kruskal-wallis test with application to a mouse peritoneal cavity study.

    Science.gov (United States)

    Fan, Chunpeng; Zhang, Donghui; Zhang, Cun-Hui

    2011-03-01

    As the nonparametric generalization of the one-way analysis of variance model, the Kruskal-Wallis test applies when the goal is to test the difference between multiple samples and the underlying population distributions are nonnormal or unknown. Although the Kruskal-Wallis test has been widely used for data analysis, power and sample size methods for this test have been investigated to a much lesser extent. This article proposes new power and sample size calculation methods for the Kruskal-Wallis test based on the pilot study in either a completely nonparametric model or a semiparametric location model. No assumption is made on the shape of the underlying population distributions. Simulation results show that, in terms of sample size calculation for the Kruskal-Wallis test, the proposed methods are more reliable and preferable to some more traditional methods. A mouse peritoneal cavity study is used to demonstrate the application of the methods. © 2010, The International Biometric Society.

  6. STUDY OF HOME DEMONSTRATION UNITS IN A SAMPLE OF 27 COUNTIES IN NEW YORK STATE, NUMBER 3.

    Science.gov (United States)

    ALEXANDER, FRANK D.; HARSHAW, JEAN

    AN EXPLORATORY STUDY EXAMINED CHARACTERISTICS OF 1,128 HOME DEMONSTRATION UNITS TO SUGGEST HYPOTHESES AND SCOPE FOR A MORE INTENSIVE STUDY OF A SMALL SAMPLE OF UNITS, AND TO PROVIDE GUIDANCE IN SAMPLING. DATA WERE OBTAINED FROM A SPECIALLY DESIGNED MEMBERSHIP CARD USED IN 1962. UNIT SIZE AVERAGED 23.6 MEMBERS BUT THE RANGE WAS FAIRLY GREAT. A NEED…

  7. Analysis of the Touch-And-Go Surface Sampling Concept for Comet Sample Return Missions

    Science.gov (United States)

    Mandic, Milan; Acikmese, Behcet; Bayard, David S.; Blackmore, Lars

    2012-01-01

    This paper studies the Touch-and-Go (TAG) concept for enabling a spacecraft to take a sample from the surface of a small primitive body, such as an asteroid or comet. The idea behind the TAG concept is to let the spacecraft descend to the surface, make contact with the surface for several seconds, and then ascend to a safe location. Sampling would be accomplished by an end-effector that is active during the few seconds of surface contact. The TAG event is one of the most critical events in a primitive body sample-return mission. The purpose of this study is to evaluate the dynamic behavior of a representative spacecraft during the TAG event, i.e., immediately prior, during, and after surface contact of the sampler. The study evaluates the sample-collection performance of the proposed sampling end-effector, in this case a brushwheel sampler, while acquiring material from the surface during the contact. A main result of the study is a guidance and control (G&C) validation of the overall TAG concept, in addition to specific contributions to demonstrating the effectiveness of using nonlinear clutch mechanisms in the sampling arm joints, and increasing the length of the sampling arms to improve robustness.

  8. Validation of a new HPV self-sampling device for cervical cancer screening: The Cervical and Self-Sample In Screening (CASSIS) study.

    Science.gov (United States)

    El-Zein, Mariam; Bouten, Sheila; Louvanto, Karolina; Gilbert, Lucy; Gotlieb, Walter; Hemmings, Robert; Behr, Marcel A; Franco, Eduardo L; Liang, Victoria; Martins, Claudia; Duarte, Silvy; Sarban, Natalia; Geddes, Patricia; Massa, Ana; Samios, Kathrin; Aboufadl, Siham; Verdon, Sophie; Pereria, Cynthia; Lacroix, Isabelle

    2018-04-17

    We compared the self-sampling performance of the newly designed HerSwab™ device with a physician-collected cervical sample and another self-sample using the cobas® PCR Female swab for the detection of cervical intraepithelial neoplasia (CIN) and cancer. Women referred for colposcopy at McGill University affiliated hospital clinics collected two consecutive self-samples, one with HerSwab™ and one with cobas® swab, after receiving instructions. The order of sampling was randomized. The colposcopist then collected a cervical sample and conducted a colposcopic examination. Samples were tested for human papillomavirus (HPV) DNA. Sensitivity and specificity to detect CIN2+ and respective 95% confidence intervals (CI) were calculated to compare sampling approaches. The HPV testing agreement between samples was measured using the Kappa statistic. Of 1217 women enrolled, 1076 had complete results for HPV and cytology; 148 (13.8%) had CIN1, 147 (13.7%) had CIN2/3, and 5 (0.5%) had cancer. There was very good agreement between methods for HPV detection (HerSwab™ versus physician: kappa=0.84; cobas® swabs versus physician: kappa=0.81; HerSwab™ versus cobas® swabs: kappa=0.87). The sensitivity of HPV detection for CIN2+ was 87.6% (95%CI: 79.8-93.2) with self-sampling using HerSwab™, 88.6% (95%CI: 80.9-94.0) with self-sampling using the cobas® swab, and 92.4% (95%CI: 85.5-96.7) with physician sampling. Corresponding estimates of specificity were 58.1% (95%CI: 54.1-62.1), 55.0% (95%CI: 50.9-59.0) and 58.7% (95%CI: 54.6-62.6). Cytology (ASC-US or more severe) done on the physician-collected specimen was 80.2% (95%CI: 70.8-87.6) sensitive and 61.4% (95%CI: 57.2-65.5) specific for CIN2+. The HerSwab™ had good agreement with physician sampling in detecting HPV, and adequate performance in detecting high-grade lesions among women referred to colposcopy for abnormal cytology. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Cr(VI) generation during sample preparation of solid samples – A ...

    African Journals Online (AJOL)

    Cr(VI) generation during sample preparation of solid samples – A chromite ore case study. R.I Glastonbury, W van der Merwe, J.P Beukes, P.G van Zyl, G Lachmann, C.J.H Steenkamp, N.F Dawson, M.H Stewart ...

  10. Software engineering the mixed model for genome-wide association studies on large samples

    Science.gov (United States)

    Mixed models improve the ability to detect phenotype-genotype associations in the presence of population stratification and multiple levels of relatedness in genome-wide association studies (GWAS), but for large data sets the resource consumption becomes impractical. At the same time, the sample siz...

  11. Transmission of 14 MeV neutrons through concrete, soil, sugar, wood and coal samples - a Monte Carlo Study

    International Nuclear Information System (INIS)

    Abdelmonem, M.S.; Naqvi, A.A.

    2006-01-01

    Full text: Fast neutrons transmission measurements are ideal for the elemental analysis of bulk samples. In particular, they can be used to determine the hydrogen concentration in bulk samples. In the present study, Monte Carlo simulations have been carried to calculate the intensity of 14 MeV neutrons transmitted through concrete, soil, sugar, wood and coal samples. The simulated set-up consists of a cylindrical sample, placed at a distance of 9 cm from the neutron source. Fast neutrons transmitted through the sample are collimated through a double truncated neutron collimator to a fast neutron detector. The collimator contains a mixture of paraffin and lithium carbonate. In this study, transmitted intensity of fast neutron through each sample was calculated as a function of moisture contents of the sample for 14 MeV neutrons. The moisture contents of the samples were varied over 0-7 wt. %. The calculated intensity of 14 MeV neutrons transmitted through the samples, shows effects related to fast neutron thermalization in hydrogen of moisture and energy dependence of neutron transmission through the sample materials. This is clearly shown by different gradients of neutron yield vs moisture content curves of these samples. The gradient of the neutron yield curves for the 14 MeV neutrons has a lower value than those reported for a 241 Am-Be neutron source

  12. Multiscale study on stochastic reconstructions of shale samples

    Science.gov (United States)

    Lili, J.; Lin, M.; Jiang, W. B.

    2016-12-01

    Shales are known to have multiscale pore systems, composed of macroscale fractures, micropores, and nanoscale pores within gas or oil-producing organic material. Also, shales are fissile and laminated, and the heterogeneity in horizontal is quite different from that in vertical. Stochastic reconstructions are extremely useful in situations where three-dimensional information is costly and time consuming. Thus the purpose of our paper is to reconstruct stochastically equiprobable 3D models containing information from several scales. In this paper, macroscale and microscale images of shale structure in the Lower Silurian Longmaxi are obtained by X-ray microtomography and nanoscale images are obtained by scanning electron microscopy. Each image is representative for all given scales and phases. Especially, the macroscale is four times coarser than the microscale, which in turn is four times lower in resolution than the nanoscale image. Secondly, the cross correlation-based simulation method (CCSIM) and the three-step sampling method are combined together to generate stochastic reconstructions for each scale. It is important to point out that the boundary points of pore and matrix are selected based on multiple-point connectivity function in the sampling process, and thus the characteristics of the reconstructed image can be controlled indirectly. Thirdly, all images with the same resolution are developed through downscaling and upscaling by interpolation, and then we merge multiscale categorical spatial data into a single 3D image with predefined resolution (the microscale image). 30 realizations using the given images and the proposed method are generated. The result reveals that the proposed method is capable of preserving the multiscale pore structure, both vertically and horizontally, which is necessary for accurate permeability prediction. The variogram curves and pore-size distribution for both original 3D sample and the generated 3D realizations are compared

  13. Experimental study of laser ablation as sample introduction technique for inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Van Winckel, S.

    2001-01-01

    The contribution consists of an abstract of a PhD thesis. In the PhD study, several complementary applications of laser-ablation were investigated in order to characterise experimentally laser ablation (LA) as a sample introduction technique for ICP-MS. Three applications of LA as a sample introduction technique are discussed: (1) the microchemical analysis of the patina of weathered marble; (2) the possibility to measure isotope ratios (in particular Pb isotope ratios in archaeological bronze artefacts); and (3) the determination of Si in Al as part of a dosimetric study of the BR2 reactor vessel

  14. Gas sampling calorimeter studies in proportional, saturated avalanche, and streamer modes

    International Nuclear Information System (INIS)

    Atac, M.; Bedeschi, F.; Yoh, J.; Morse, R.; Procario, M.

    1982-01-01

    Recently, satisfactory new results were obtained at SLAC from gas sampling calorimeters running in the saturated avalanche mode within the energy range of 1.5 to 17.5 GeV. To study the higher energy behavior of this mode, more tests were carried out in the M4 beamline at Fermilab. This paper contains results obtained from the MAC prototype electromagnetic and hadronic calorimeters running in the proportional, saturated avalanche, and the streamer regions for energies between 12 and 150 GeV

  15. An evaluation of soil sampling for 137Cs using various field-sampling volumes.

    Science.gov (United States)

    Nyhan, J W; White, G C; Schofield, T G; Trujillo, G

    1983-05-01

    The sediments from a liquid effluent receiving area at the Los Alamos National Laboratory and soils from an intensive study area in the fallout pathway of Trinity were sampled for 137Cs using 25-, 500-, 2500- and 12,500-cm3 field sampling volumes. A highly replicated sampling program was used to determine mean concentrations and inventories of 137Cs at each site, as well as estimates of spatial, aliquoting, and counting variance components of the radionuclide data. The sampling methods were also analyzed as a function of soil size fractions collected in each field sampling volume and of the total cost of the program for a given variation in the radionuclide survey results. Coefficients of variation (CV) of 137Cs inventory estimates ranged from 0.063 to 0.14 for Mortandad Canyon sediments, whereas CV values for Trinity soils were observed from 0.38 to 0.57. Spatial variance components of 137Cs concentration data were usually found to be larger than either the aliquoting or counting variance estimates and were inversely related to field sampling volume at the Trinity intensive site. Subsequent optimization studies of the sampling schemes demonstrated that each aliquot should be counted once, and that only 2-4 aliquots out of as many as 30 collected need be assayed for 137Cs. The optimization studies showed that as sample costs increased to 45 man-hours of labor per sample, the variance of the mean 137Cs concentration decreased dramatically, but decreased very little with additional labor.

  16. {sup 14}C sample preparation for AMS microdosing studies at Lund University using online combustion and septa-sealed vials

    Energy Technology Data Exchange (ETDEWEB)

    Sydoff, Marie, E-mail: marie.sydoff@med.lu.s [Department of Clinical Sciences, Medical Radiation Physics, Malmo University Hospital, SE-205 02 Malmoe (Sweden); Lund University, Department of Physics, Division of Nuclear Physics, P.O. Box 118, SE-221 00 Lund (Sweden); Stenstroem, Kristina [Lund University, Department of Physics, Division of Nuclear Physics, P.O. Box 118, SE-221 00 Lund (Sweden)

    2010-04-15

    The Department of Physics at Lund University is participating in a European Union project called EUMAPP (European Union Microdose AMS Partnership Programme), in which sample preparation and accelerator mass spectrometry (AMS) measurements of biological samples from microdosing studies have been made. This paper describes a simplified method of converting biological samples to solid graphite for {sup 14}C analysis with AMS. The method is based on online combustion of the samples, and reduction of CO{sub 2} in septa-sealed vials. The septa-sealed vials and disposable materials are used to eliminate sample cross-contamination. Measurements of ANU and Ox I standards show deviations of 2% and 3%, respectively, relative to reference values. This level of accuracy is sufficient for biological samples from microdosing studies. Since the method has very few handling steps from sample to graphite, the risk of failure during the sample preparation process is minimized, making the method easy to use in routine preparation of samples.

  17. Methodology Series Module 5: Sampling Strategies

    Science.gov (United States)

    Setia, Maninder Singh

    2016-01-01

    Once the research question and the research design have been finalised, it is important to select the appropriate sample for the study. The method by which the researcher selects the sample is the ‘ Sampling Method’. There are essentially two types of sampling methods: 1) probability sampling – based on chance events (such as random numbers, flipping a coin etc.); and 2) non-probability sampling – based on researcher's choice, population that accessible & available. Some of the non-probability sampling methods are: purposive sampling, convenience sampling, or quota sampling. Random sampling method (such as simple random sample or stratified random sample) is a form of probability sampling. It is important to understand the different sampling methods used in clinical studies and mention this method clearly in the manuscript. The researcher should not misrepresent the sampling method in the manuscript (such as using the term ‘ random sample’ when the researcher has used convenience sample). The sampling method will depend on the research question. For instance, the researcher may want to understand an issue in greater detail for one particular population rather than worry about the ‘ generalizability’ of these results. In such a scenario, the researcher may want to use ‘ purposive sampling’ for the study. PMID:27688438

  18. Flow cytometry for feline lymphoma: a retrospective study about pre-analytical factors possibly affecting the quality of samples

    Directory of Open Access Journals (Sweden)

    Serena Bernardi

    2017-05-01

    Full Text Available Introduction Flow cytometry (FC is an increasingly required technique on which veterinary oncologists rely to have an accurate, fast, minimally invasive lymphoma or leukemia diagnosis. FC has been studied and applied with great results in canine oncology, whereas in feline oncology the use of this technique is still to be experienced. This is mainly due to a supposed discomfort in sampling, because of the high prevalence of intra-abdominal lymphomas. The purpose of the present study is to investigate whether any pre-analytical factor might affect the quality of suspected feline lymphoma samples for FC analysis. Methods 97 consecutive samples of suspected feline lymphoma were retrospectively selected from the authors’ institution FC database. The referring veterinarians were recalled and interrogated about several different variables, including signalling, features of the lesion, features of the sampling procedure and the experience of veterinarians performing the sampling. Statistical analyses were performed to assess the possible influence of these variables on the cellularity of the samples and the likelihood of being finally processed for FC. Results None of the investigated variables significantly influenced the quality of the submitted samples, but the needle size, with 21G needles providing the highest cellularity (Table 1. Notably, the samples quality did not vary between peripheral and intra-abdominal lesions. Sample cellularity alone influenced the likelihood of being processed. About a half of the cats required pharmacological restraint. Side effects were reported in one case only (transient swelling after peripheral lymph node sampling. Conclusions FC can be safely applied to cases of suspected feline lymphomas, even for intra-abdominal lesions. 21G needle should be preferred for sampling. This study provides the bases for the spread of this minimally invasive, fast and cost-effective technique in feline medicine.

  19. Assessment of dust sampling methods for the study of cultivable-microorganism exposure in stables.

    NARCIS (Netherlands)

    Normand, A.C.; Vacheyrou, M.; Sudre, B.; Heederik, D.|info:eu-repo/dai/nl/072910542; Piarroux, R.

    2009-01-01

    Studies have shown a link between living on a farm, exposure to microbial components (e.g., endotoxins or beta-d-glucans), and a lower risk for allergic diseases and asthma. Due to the lack of validated sampling methods, studies of asthma and atopy have not relied on exposure assessment based on

  20. Lifetime Prevalence of Suicide Attempts Among Sexual Minority Adults by Study Sampling Strategies: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Hottes, Travis Salway; Bogaert, Laura; Rhodes, Anne E; Brennan, David J; Gesink, Dionne

    2016-05-01

    Previous reviews have demonstrated a higher risk of suicide attempts for lesbian, gay, and bisexual (LGB) persons (sexual minorities), compared with heterosexual groups, but these were restricted to general population studies, thereby excluding individuals sampled through LGB community venues. Each sampling strategy, however, has particular methodological strengths and limitations. For instance, general population probability studies have defined sampling frames but are prone to information bias associated with underreporting of LGB identities. By contrast, LGB community surveys may support disclosure of sexuality but overrepresent individuals with strong LGB community attachment. To reassess the burden of suicide-related behavior among LGB adults, directly comparing estimates derived from population- versus LGB community-based samples. In 2014, we searched MEDLINE, EMBASE, PsycInfo, CINAHL, and Scopus databases for articles addressing suicide-related behavior (ideation, attempts) among sexual minorities. We selected quantitative studies of sexual minority adults conducted in nonclinical settings in the United States, Canada, Europe, Australia, and New Zealand. Random effects meta-analysis and meta-regression assessed for a difference in prevalence of suicide-related behavior by sample type, adjusted for study or sample-level variables, including context (year, country), methods (medium, response rate), and subgroup characteristics (age, gender, sexual minority construct). We examined residual heterogeneity by using τ(2). We pooled 30 cross-sectional studies, including 21,201 sexual minority adults, generating the following lifetime prevalence estimates of suicide attempts: 4% (95% confidence interval [CI] = 3%, 5%) for heterosexual respondents to population surveys, 11% (95% CI = 8%, 15%) for LGB respondents to population surveys, and 20% (95% CI = 18%, 22%) for LGB respondents to community surveys (Figure 1). The difference in LGB estimates by sample

  1. Social anhedonia and schizotypy in a community sample: the Maryland longitudinal study of schizotypy.

    Science.gov (United States)

    Blanchard, Jack J; Collins, Lindsay M; Aghevli, Minu; Leung, Winnie W; Cohen, Alex S

    2011-05-01

    Social anhedonia has been employed in psychometric high-risk studies to identify putative schizotypes. To date, this research has focused almost exclusively on college samples. The current study sought to examine the validity of social anhedonia as an indicator of risk for schizophrenia-spectrum disorders within a community sample. Furthermore, we evaluated the role of other individual difference variables in accounting for variable clinical severity within the social anhedonia group including trait affectivity, social support, and family environment. Following the mailed questionnaire screening of 2434 eighteen-year olds, laboratory assessments were conducted with individuals identified as being high in social anhedonia (n=86) and a comparison sample (n=89). Compared with the control group, individuals in the social anhedonia group were found to have higher rates of mood disorders, elevated schizophrenia-spectrum personality disorder characteristics, greater negative symptom characteristics, and lower global functioning. Individuals within the social anhedonia group also reported greater trait negative affectivity, lower positive affectivity, less social support, and more family conflict. Low social support and problematic family environment were found to be related to elevations in spectrum personality disorder characteristics and poorer functioning within the social anhedonia group. These cross-sectional findings from a community sample provide further support for social anhedonia as a possible indicator of schizotypy. © The Author 2009. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center. All rights reserved.

  2. The role of sample preparation in interpretation of trace element concentration variability in moss bioindication studies

    Science.gov (United States)

    Migaszewski, Z.M.; Lamothe, P.J.; Crock, J.G.; Galuszka, A.; Dolegowska, S.

    2011-01-01

    Trace element concentrations in plant bioindicators are often determined to assess the quality of the environment. Instrumental methods used for trace element determination require digestion of samples. There are different methods of sample preparation for trace element analysis, and the selection of the best method should be fitted for the purpose of a study. Our hypothesis is that the method of sample preparation is important for interpretation of the results. Here we compare the results of 36 element determinations performed by ICP-MS on ashed and on acid-digested (HNO3, H2O2) samples of two moss species (Hylocomium splendens and Pleurozium schreberi) collected in Alaska and in south-central Poland. We found that dry ashing of the moss samples prior to analysis resulted in considerably lower detection limits of all the elements examined. We also show that this sample preparation technique facilitated the determination of interregional and interspecies differences in the chemistry of trace elements. Compared to the Polish mosses, the Alaskan mosses displayed more positive correlations of the major rock-forming elements with ash content, reflecting those elements' geogenic origin. Of the two moss species, P. schreberi from both Alaska and Poland was also highlighted by a larger number of positive element pair correlations. The cluster analysis suggests that the more uniform element distribution pattern of the Polish mosses primarily reflects regional air pollution sources. Our study has shown that the method of sample preparation is an important factor in statistical interpretation of the results of trace element determinations. ?? 2010 Springer-Verlag.

  3. Use of X-ray diffraction technique and chemometrics to aid soil sampling strategies in traceability studies.

    Science.gov (United States)

    Bertacchini, Lucia; Durante, Caterina; Marchetti, Andrea; Sighinolfi, Simona; Silvestri, Michele; Cocchi, Marina

    2012-08-30

    Aim of this work is to assess the potentialities of the X-ray powder diffraction technique as fingerprinting technique, i.e. as a preliminary tool to assess soil samples variability, in terms of geochemical features, in the context of food geographical traceability. A correct approach to sampling procedure is always a critical issue in scientific investigation. In particular, in food geographical traceability studies, where the cause-effect relations between the soil of origin and the final foodstuff is sought, a representative sampling of the territory under investigation is certainly an imperative. This research concerns a pilot study to investigate the field homogeneity with respect to both field extension and sampling depth, taking also into account the seasonal variability. Four Lambrusco production sites of the Modena district were considered. The X-Ray diffraction spectra, collected on the powder of each soil sample, were treated as fingerprint profiles to be deciphered by multivariate and multi-way data analysis, namely PCA and PARAFAC. The differentiation pattern observed in soil samples, as obtained by this fast and non-destructive analytical approach, well matches with the results obtained by characterization with other costly analytical techniques, such as ICP/MS, GFAAS, FAAS, etc. Thus, the proposed approach furnishes a rational basis to reduce the number of soil samples to be collected for further analytical characterization, i.e. metals content, isotopic ratio of radiogenic element, etc., while maintaining an exhaustive description of the investigated production areas. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Does increasing the size of bi-weekly samples of records influence results when using the Global Trigger Tool? An observational study of retrospective record reviews of two different sample sizes.

    Science.gov (United States)

    Mevik, Kjersti; Griffin, Frances A; Hansen, Tonje E; Deilkås, Ellen T; Vonen, Barthold

    2016-04-25

    To investigate the impact of increasing sample of records reviewed bi-weekly with the Global Trigger Tool method to identify adverse events in hospitalised patients. Retrospective observational study. A Norwegian 524-bed general hospital trust. 1920 medical records selected from 1 January to 31 December 2010. Rate, type and severity of adverse events identified in two different samples sizes of records selected as 10 and 70 records, bi-weekly. In the large sample, 1.45 (95% CI 1.07 to 1.97) times more adverse events per 1000 patient days (39.3 adverse events/1000 patient days) were identified than in the small sample (27.2 adverse events/1000 patient days). Hospital-acquired infections were the most common category of adverse events in both the samples, and the distributions of the other categories of adverse events did not differ significantly between the samples. The distribution of severity level of adverse events did not differ between the samples. The findings suggest that while the distribution of categories and severity are not dependent on the sample size, the rate of adverse events is. Further studies are needed to conclude if the optimal sample size may need to be adjusted based on the hospital size in order to detect a more accurate rate of adverse events. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. Large sample neutron activation analysis of a reference inhomogeneous sample

    International Nuclear Information System (INIS)

    Vasilopoulou, T.; Athens National Technical University, Athens; Tzika, F.; Stamatelatos, I.E.; Koster-Ammerlaan, M.J.J.

    2011-01-01

    A benchmark experiment was performed for Neutron Activation Analysis (NAA) of a large inhomogeneous sample. The reference sample was developed in-house and consisted of SiO 2 matrix and an Al-Zn alloy 'inhomogeneity' body. Monte Carlo simulations were employed to derive appropriate correction factors for neutron self-shielding during irradiation as well as self-attenuation of gamma rays and sample geometry during counting. The large sample neutron activation analysis (LSNAA) results were compared against reference values and the trueness of the technique was evaluated. An agreement within ±10% was observed between LSNAA and reference elemental mass values, for all matrix and inhomogeneity elements except Samarium, provided that the inhomogeneity body was fully simulated. However, in cases that the inhomogeneity was treated as not known, the results showed a reasonable agreement for most matrix elements, while large discrepancies were observed for the inhomogeneity elements. This study provided a quantification of the uncertainties associated with inhomogeneity in large sample analysis and contributed to the identification of the needs for future development of LSNAA facilities for analysis of inhomogeneous samples. (author)

  6. Are most samples of animals systematically biased? Consistent individual trait differences bias samples despite random sampling.

    Science.gov (United States)

    Biro, Peter A

    2013-02-01

    Sampling animals from the wild for study is something nearly every biologist has done, but despite our best efforts to obtain random samples of animals, 'hidden' trait biases may still exist. For example, consistent behavioral traits can affect trappability/catchability, independent of obvious factors such as size and gender, and these traits are often correlated with other repeatable physiological and/or life history traits. If so, systematic sampling bias may exist for any of these traits. The extent to which this is a problem, of course, depends on the magnitude of bias, which is presently unknown because the underlying trait distributions in populations are usually unknown, or unknowable. Indeed, our present knowledge about sampling bias comes from samples (not complete population censuses), which can possess bias to begin with. I had the unique opportunity to create naturalized populations of fish by seeding each of four small fishless lakes with equal densities of slow-, intermediate-, and fast-growing fish. Using sampling methods that are not size-selective, I observed that fast-growing fish were up to two-times more likely to be sampled than slower-growing fish. This indicates substantial and systematic bias with respect to an important life history trait (growth rate). If correlations between behavioral, physiological and life-history traits are as widespread as the literature suggests, then many animal samples may be systematically biased with respect to these traits (e.g., when collecting animals for laboratory use), and affect our inferences about population structure and abundance. I conclude with a discussion on ways to minimize sampling bias for particular physiological/behavioral/life-history types within animal populations.

  7. A Study on Primary and Secondary School Students' Misconceptions about Greenhouse Effect (Erzurum Sampling)

    Science.gov (United States)

    Gul, Seyda; Yesilyurt, Selami

    2011-01-01

    The aim of this study is to determine what level of primary and secondary school students' misconceptions related to greenhouse effect is. Study group consists of totally 280 students attended to totally 8 primary and secondary schools (4 primary school, 4 secondary school) which were determined with convenient sampling method from center of…

  8. Effects of sample size and sampling frequency on studies of brown bear home ranges and habitat use

    Science.gov (United States)

    Arthur, Steve M.; Schwartz, Charles C.

    1999-01-01

    We equipped 9 brown bears (Ursus arctos) on the Kenai Peninsula, Alaska, with collars containing both conventional very-high-frequency (VHF) transmitters and global positioning system (GPS) receivers programmed to determine an animal's position at 5.75-hr intervals. We calculated minimum convex polygon (MCP) and fixed and adaptive kernel home ranges for randomly-selected subsets of the GPS data to examine the effects of sample size on accuracy and precision of home range estimates. We also compared results obtained by weekly aerial radiotracking versus more frequent GPS locations to test for biases in conventional radiotracking data. Home ranges based on the MCP were 20-606 km2 (x = 201) for aerial radiotracking data (n = 12-16 locations/bear) and 116-1,505 km2 (x = 522) for the complete GPS data sets (n = 245-466 locations/bear). Fixed kernel home ranges were 34-955 km2 (x = 224) for radiotracking data and 16-130 km2 (x = 60) for the GPS data. Differences between means for radiotracking and GPS data were due primarily to the larger samples provided by the GPS data. Means did not differ between radiotracking data and equivalent-sized subsets of GPS data (P > 0.10). For the MCP, home range area increased and variability decreased asymptotically with number of locations. For the kernel models, both area and variability decreased with increasing sample size. Simulations suggested that the MCP and kernel models required >60 and >80 locations, respectively, for estimates to be both accurate (change in area bears. Our results suggest that the usefulness of conventional radiotracking data may be limited by potential biases and variability due to small samples. Investigators that use home range estimates in statistical tests should consider the effects of variability of those estimates. Use of GPS-equipped collars can facilitate obtaining larger samples of unbiased data and improve accuracy and precision of home range estimates.

  9. Understanding the origin and evolution of water in the Moon through lunar sample studies.

    Science.gov (United States)

    Anand, Mahesh; Tartèse, Romain; Barnes, Jessica J

    2014-09-13

    A paradigm shift has recently occurred in our knowledge and understanding of water in the lunar interior. This has transpired principally through continued analysis of returned lunar samples using modern analytical instrumentation. While these recent studies have undoubtedly measured indigenous water in lunar samples they have also highlighted our current limitations and some future challenges that need to be overcome in order to fully understand the origin, distribution and evolution of water in the lunar interior. Another exciting recent development in the field of lunar science has been the unambiguous detection of water or water ice on the surface of the Moon through instruments flown on a number of orbiting spacecraft missions. Considered together, sample-based studies and those from orbit strongly suggest that the Moon is not an anhydrous planetary body, as previously believed. New observations and measurements support the possibility of a wet lunar interior and the presence of distinct reservoirs of water on the lunar surface. Furthermore, an approach combining measurements of water abundance in lunar samples and its hydrogen isotopic composition has proved to be of vital importance to fingerprint and elucidate processes and source(s) involved in giving rise to the lunar water inventory. A number of sources are likely to have contributed to the water inventory of the Moon ranging from primordial water to meteorite-derived water ice through to the water formed during the reaction of solar wind hydrogen with the lunar soil. Perhaps two of the most striking findings from these recent studies are the revelation that at least some portions of the lunar interior are as water-rich as some Mid-Ocean Ridge Basalt source regions on Earth and that the water in the Earth and the Moon probably share a common origin. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  10. Aragonite-Calcite Inversion During Biogenic Carbonate Sampling: Considerations for Interpreting Isotopic Measurements in Paleoclimate Studies

    Science.gov (United States)

    Waite, A. J.; Swart, P. K.

    2011-12-01

    As aragonite is the metastable polymorph of calcium carbonate, it lends itself to monotropic inversion to the more stable polymorph, calcite. This inversion is possible through an increase in the temperature and pressure conditions to which the sample is exposed and, although first noted nearly a century ago, has been primarily discussed in the context of sample roasting prior to analyses in paleoclimatological studies. Over the last several decades, however, researchers have found evidence to suggest that the friction associated with the sampling of biogenic carbonates via milling/drilling also induces inversion. Furthermore, this inversion may be associated with a shift in measured oxygen isotopic values and ultimately have significant implications for the interpretation of paleoclimatic reconstructions. Despite this, the isotopic heterogeneity of biogenic aragonite skeletons makes the effects of inversion challenging to test and the subject remains underrepresented in the literature. Here we present a first order study into the effects of milling on both the mineralogy and isotopic compositions measured in sclerosponges, corals, and molluscs. X-Ray diffraction analysis of samples hand ground with a mortar and pestle reveal 100% aragonitic skeletons. Conversely, samples milled with a computerized micromill show measurable inversion to calcite. On average, percent inversion of aragonite to calcite for individual specimens was 15% for sclerosponges, 16% for corals, and 9% for molluscs. Isotopic data from these specimens show that the higher the percentage of aragonite inverted to calcite, the more depleted the measured oxygen isotopic values. In the largest of the datasets (sclerosponges), it is evident that the range of oxygen isotope values from milled samples (-0.02 to +0.84%) exceeds the range in values for those samples which were hand ground and showed no inversion (+0.53 to +0.90%). This, coupled with the strong correlation between the two variables

  11. Quantification of damage in DNA recovered from highly degraded samples – a case study on DNA in faeces

    Directory of Open Access Journals (Sweden)

    Eveson J Paige

    2006-08-01

    Full Text Available Abstract Background Poorly preserved biological tissues have become an important source of DNA for a wide range of zoological studies. Measuring the quality of DNA obtained from these samples is often desired; however, there are no widely used techniques available for quantifying damage in highly degraded DNA samples. We present a general method that can be used to determine the frequency of polymerase blocking DNA damage in specific gene-regions in such samples. The approach uses quantitative PCR to measure the amount of DNA present at several fragment sizes within a sample. According to a model of random degradation the amount of available template will decline exponentially with increasing fragment size in damaged samples, and the frequency of DNA damage (λ can be estimated by determining the rate of decline. Results The method is illustrated through the analysis of DNA extracted from sea lion faecal samples. Faeces contain a complex mixture of DNA from several sources and different components are expected to be differentially degraded. We estimated the frequency of DNA damage in both predator and prey DNA within individual faecal samples. The distribution of fragment lengths for each target fit well with the assumption of a random degradation process and, in keeping with our expectations, the estimated frequency of damage was always less in predator DNA than in prey DNA within the same sample (mean λpredator = 0.0106 per nucleotide; mean λprey = 0.0176 per nucleotide. This study is the first to explicitly define the amount of template damage in any DNA extracted from faeces and the first to quantify the amount of predator and prey DNA present within individual faecal samples. Conclusion We present an approach for characterizing mixed, highly degraded PCR templates such as those often encountered in ecological studies using non-invasive samples as a source of DNA, wildlife forensics investigations and ancient DNA research. This method will

  12. Study of irradiation damage by fast neutrons in samples of Portland cement

    International Nuclear Information System (INIS)

    Lucki, G.; Rosa Junior, A.A.

    1984-01-01

    The effect of neutron irradiation in samples of Portland cement was evaluated, using the resonance frequency method and pulse velocity of ultra-sound techniques. The samples were divided in three groups: 1) monitoring samples; 2) samples submitted to gamma heating; 3) Irradiated samples. In the sample preparation, it was used the Portland Santa Rita CP 320 cement, and water-cement rate of 0.40 l/Kg. The irradiation was done in the research reactor IEA-R1, at IPEN - CNEN/SP, with an integrated flux of 7.2 x 10 18 n/cm 2 (E approx. 1 MeV). Some damage were detected, due to the neutron flux, and by the thermal effect of gamma heating. (E.G.) [pt

  13. Shame, personality, and social anxiety symptoms in Chinese and American nonclinical samples: a cross-cultural study.

    Science.gov (United States)

    Zhong, Jie; Wang, Aimin; Qian, Mingyi; Zhang, Lili; Gao, Jun; Yang, Jianxiang; Li, Bo; Chen, Ping

    2008-01-01

    Shame has been observed to play an important role in social anxiety in China [Xu, 1982]. Shame and personality factors, such as neuroticism and introversion-extraversion, are also related to social anxiety symptoms in Chinese college students [Li et al., 2003]. The aim of this study was to explore cross-cultural differences of the effects of shame and personality on social anxiety using the Experience Scale of Shame, the Eysenck Personality Questionnaire-Revised Short Scale and Social Anxiety Inventory. Data were collected from both a Chinese sample (n=211, 66 males and 145 females, average ages 20.12+/-1.56 years) and an American sample (n=211, 66 males and 145 females, average ages 20.22+/-1.90 years) of college students. The structural equation modeling (SEM) was performed separately for the Chinese and American samples. The SEM results reveal a shame-mediating model, which is adaptive and only in the Chinese sample. This suggests that shame is a mediator between the Chinese personality and social anxiety. The shame factor did not play the same role in the American sample. This empirical study supports the hypothesis that shame has a more important effect on social anxiety in the Chinese culture compared to its effect on Americans. (c) 2007 Wiley-Liss, Inc.

  14. Studies on radon concentration in underground water samples in and around Kabini river basin

    International Nuclear Information System (INIS)

    Yashaswini, T.; Ningappa, C.; Niranjan, R.S.; Sannappa, J.

    2017-01-01

    Radon is a radioactive inert gas, a decay product of radium, causes environmental health problems like lung cancer. Radium present in the earth crest continuously releases radon into underground water. From the point view of health, the study of radon concentration level in underground water base line data is important. In the present study, radon concentration in underground water have been measured in 40 underground water samples collected in and around Kabini River of Karnataka State by using Emanometry technique. The radon concentration in the study area varies from 21.2 to 168.2Bq.l -1 with a geometrical mean value of 73.3 Bq.l -1 . The physicochemical parameters of water such as chloride, Fluoride, nitrite, sulphate, TDS are measured in the same samples in order to know about the impact of these parameters on radon concentration and their health risks to the general public. The experimental techniques and results obtained are discussed in the presentation. (author)

  15. A computational study of a fast sampling valve designed to sample soot precursors inside a forming diesel spray plume

    International Nuclear Information System (INIS)

    Dumitrescu, Cosmin; Puzinauskas, Paulius V.; Agrawal, Ajay K.; Liu, Hao; Daly, Daniel T.

    2009-01-01

    Accurate chemical reaction mechanisms are critically needed to fully optimize combustion strategies for modern internal-combustion engines. These mechanisms are needed to predict emission formation and the chemical heat release characteristics for traditional direct-injection diesel as well as recently-developed and proposed variant combustion strategies. Experimental data acquired under conditions representative of such combustion strategies are required to validate these reaction mechanisms. This paper explores the feasibility of developing a fast sampling valve which extracts reactants at known locations in the spray reaction structure to provide these data. CHEMKIN software is used to establish the reaction timescales which dictate the required fast sampling capabilities. The sampling process is analyzed using separate FLUENT and CHEMKIN calculations. The non-reacting FLUENT CFD calculations give a quantitative estimate of the sample quantity as well as the fluid mixing and thermal history. A CHEMKIN reactor network has been created that reflects these mixing and thermal time scales and allows a theoretical evaluation of the quenching process

  16. Dynamic telecytologic evaluation of imprint cytology samples from CT-guided lung biopsies: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut [Otto Wagner Hospital, Department of Radiology, Vienna (Austria); Medical University of Vienna, Department of Radiology, Vienna (Austria); Medical University of Vienna, Vienna General Hospital, Department of Radiology, Vienna (Austria); Hoffmann, Elisabeth; Schober, Ewald; Mostbeck, Gerhard [Otto Wagner Hospital, Department of Radiology, Vienna (Austria); Bernhardt, Klaus; Schalleschak, Johann [Otto Wagner Hospital, Department of Laboratory Medicine, Vienna (Austria); Rowhani, Marcel [Otto Wagner Hospital, Department of Respiratory and Critical Care Medicine, Vienna (Austria); Weber, Michael [Medical University of Vienna, Department of Radiology, Vienna (Austria)

    2011-09-15

    This study assessed the feasibility of telecytological evaluation of samples from CT-guided lung biopsies using a dynamic telecytological system in which the microscope was operated by personnel from the radiology department at the site of the biopsy and a cytologist off-site diagnosed the biopsy sample. 45 imprint samples from CT-guided biopsies of lung lesions were reviewed by two cytologists using a telecytological microscope (Olympus BX51, Tokyo, Japan). The telecytological microscope was operated by one radiologist and one radiology technician. The cytological samples were classified by a cytologist into four categories: benign, malignant, atypical cells of undetermined significance, and non-diagnostic. The results were compared with those of a previous consensus reading of two independent cytologists (gold standard). When the radiologist was operating the microscope, the diagnostic accuracy was 100% as both cytologists came to the correct diagnosis in all samples. When the technician operated the microscope, two diagnoses of cyotologist 1 differed from the gold standard. Thus, the accuracy for the technician was 95.56%. Telecytological evaluation of imprint samples from CT-guided lung biopsies is feasible because it can be performed with high diagnostic accuracy if personnel from the radiology department operate the microscope. (orig.)

  17. Searching for the Optimal Sampling Solution: Variation in Invertebrate Communities, Sample Condition and DNA Quality.

    Directory of Open Access Journals (Sweden)

    Martin M Gossner

    Full Text Available There is a great demand for standardising biodiversity assessments in order to allow optimal comparison across research groups. For invertebrates, pitfall or flight-interception traps are commonly used, but sampling solution differs widely between studies, which could influence the communities collected and affect sample processing (morphological or genetic. We assessed arthropod communities with flight-interception traps using three commonly used sampling solutions across two forest types and two vertical strata. We first considered the effect of sampling solution and its interaction with forest type, vertical stratum, and position of sampling jar at the trap on sample condition and community composition. We found that samples collected in copper sulphate were more mouldy and fragmented relative to other solutions which might impair morphological identification, but condition depended on forest type, trap type and the position of the jar. Community composition, based on order-level identification, did not differ across sampling solutions and only varied with forest type and vertical stratum. Species richness and species-level community composition, however, differed greatly among sampling solutions. Renner solution was highly attractant for beetles and repellent for true bugs. Secondly, we tested whether sampling solution affects subsequent molecular analyses and found that DNA barcoding success was species-specific. Samples from copper sulphate produced the fewest successful DNA sequences for genetic identification, and since DNA yield or quality was not particularly reduced in these samples additional interactions between the solution and DNA must also be occurring. Our results show that the choice of sampling solution should be an important consideration in biodiversity studies. Due to the potential bias towards or against certain species by Ethanol-containing sampling solution we suggest ethylene glycol as a suitable sampling solution when

  18. Pharmacy in transition: A work sampling study of community pharmacists using smartphone technology.

    Science.gov (United States)

    van de Pol, Jeroen M; Geljon, Jurjen G; Belitser, Svetlana V; Frederix, Geert W J; Hövels, Anke M; Bouvy, Marcel L

    2018-03-09

    The nature of community pharmacy is changing, shifting from the preparation and distribution of medicines to the provision of cognitive pharmaceutical services (CPS); however, often the provision of traditional services leaves little time for innovative services. This study investigated the time community pharmacists spend on the tasks and activities of daily practice and to what extent they are able to implement CPS-related services in daily practice. Self-reporting work sampling was used to register the activities of community pharmacists. A smartphone application, designed specifically for this purpose, alerted participants to register their current activity five times per working day for 6 weeks. Participants also completed an online survey about baseline characteristics. Ninety-one Dutch community pharmacists provided work-sampling data (7848 registered activities). Overall, 51.5% of their time was spent on professional activities, 35.4% on semi-professional activities, and 13.1% on non-professional activities. The proportion of time devoted to CPS decreased during the workweek, whereas the time spent on traditional task increased. This study shows it is feasible to collect work-sampling data using smartphone technology. Community pharmacists spent almost half of their time on semi-professional and non-professional activities, activities that could be delegated to other staff members. In practice, the transition to CPS is hampered by competing traditional tasks, which prevents community pharmacists from profiling themselves as pharmaceutical experts in daily practice. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Comparative Study of 11 Honey Samples Sold in Riyadh Saudi Arabia

    OpenAIRE

    Al Tufail, M. A. [محمد عبد الله الطفيل; Al Araidh, I. A. [ابراهيم عبد الله العريض

    2006-01-01

    11 honey various samples commercially available in Saudi Arabia, were subjected to chemical, toxicological and bacteriological tests. The samples were checked for As and CN, presence of pollens, and for bacteria contamination. The carbohydrate profile was analyzed with HPLC. Fe, P, Ca, K, and Mg were measured with colorimetry. Toxic metals, As, Pb, Sb, Tl, and Hg were determined with ICP-MS. The samples were investigated by GC-MS. The investigation revealed the presence of syringaldehyde, men...

  20. Effect of Different Sampling Schedules on Results of Bioavailability and Bioequivalence Studies: Evaluation by Means of Monte Carlo Simulations.

    Science.gov (United States)

    Kano, Eunice Kazue; Chiann, Chang; Fukuda, Kazuo; Porta, Valentina

    2017-08-01

    Bioavailability and bioequivalence study is one of the most frequently performed investigations in clinical trials. Bioequivalence testing is based on the assumption that 2 drug products will be therapeutically equivalent when they are equivalent in the rate and extent to which the active drug ingredient or therapeutic moiety is absorbed and becomes available at the site of drug action. In recent years there has been a significant growth in published papers that use in silico studies based on mathematical simulations to analyze pharmacokinetic and pharmacodynamic properties of drugs, including bioavailability and bioequivalence aspects. The goal of this study is to evaluate the usefulness of in silico studies as a tool in the planning of bioequivalence, bioavailability and other pharmacokinetic assays, e.g., to determine an appropriate sampling schedule. Monte Carlo simulations were used to define adequate blood sampling schedules for a bioequivalence assay comparing 2 different formulations of cefadroxil oral suspensions. In silico bioequivalence studies comparing different formulation of cefadroxil oral suspensions using various sampling schedules were performed using models. An in vivo study was conducted to confirm in silico results. The results of in silico and in vivo bioequivalence studies demonstrated that schedules with fewer sampling times are as efficient as schedules with larger numbers of sampling times in the assessment of bioequivalence, but only if T max is included as a sampling time. It was also concluded that in silico studies are useful tools in the planning of bioequivalence, bioavailability and other pharmacokinetic in vivo assays. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Sample Size for Measuring Grammaticality in Preschool Children from Picture-Elicited Language Samples

    Science.gov (United States)

    Eisenberg, Sarita L.; Guo, Ling-Yu

    2015-01-01

    Purpose: The purpose of this study was to investigate whether a shorter language sample elicited with fewer pictures (i.e., 7) would yield a percent grammatical utterances (PGU) score similar to that computed from a longer language sample elicited with 15 pictures for 3-year-old children. Method: Language samples were elicited by asking forty…

  2. TRAN-STAT: statistics for environmental studies, Number 22. Comparison of soil-sampling techniques for plutonium at Rocky Flats

    International Nuclear Information System (INIS)

    Gilbert, R.O.; Bernhardt, D.E.; Hahn, P.B.

    1983-01-01

    A summary of a field soil sampling study conducted around the Rocky Flats Colorado plant in May 1977 is preseted. Several different soil sampling techniques that had been used in the area were applied at four different sites. One objective was to comparethe average 239 - 240 Pu concentration values obtained by the various soil sampling techniques used. There was also interest in determining whether there are differences in the reproducibility of the various techniques and how the techniques compared with the proposed EPA technique of sampling to 1 cm depth. Statistically significant differences in average concentrations between the techniques were found. The differences could be largely related to the differences in sampling depth-the primary physical variable between the techniques. The reproducibility of the techniques was evaluated by comparing coefficients of variation. Differences between coefficients of variation were not statistically significant. Average (median) coefficients ranged from 21 to 42 percent for the five sampling techniques. A laboratory study indicated that various sample treatment and particle sizing techniques could increase the concentration of plutonium in the less than 10 micrometer size fraction by up to a factor of about 4 compared to the 2 mm size fraction

  3. Big Data, Small Sample.

    Science.gov (United States)

    Gerlovina, Inna; van der Laan, Mark J; Hubbard, Alan

    2017-05-20

    Multiple comparisons and small sample size, common characteristics of many types of "Big Data" including those that are produced by genomic studies, present specific challenges that affect reliability of inference. Use of multiple testing procedures necessitates calculation of very small tail probabilities of a test statistic distribution. Results based on large deviation theory provide a formal condition that is necessary to guarantee error rate control given practical sample sizes, linking the number of tests and the sample size; this condition, however, is rarely satisfied. Using methods that are based on Edgeworth expansions (relying especially on the work of Peter Hall), we explore the impact of departures of sampling distributions from typical assumptions on actual error rates. Our investigation illustrates how far the actual error rates can be from the declared nominal levels, suggesting potentially wide-spread problems with error rate control, specifically excessive false positives. This is an important factor that contributes to "reproducibility crisis". We also review some other commonly used methods (such as permutation and methods based on finite sampling inequalities) in their application to multiple testing/small sample data. We point out that Edgeworth expansions, providing higher order approximations to the sampling distribution, offer a promising direction for data analysis that could improve reliability of studies relying on large numbers of comparisons with modest sample sizes.

  4. Concepts in sample size determination

    Directory of Open Access Journals (Sweden)

    Umadevi K Rao

    2012-01-01

    Full Text Available Investigators involved in clinical, epidemiological or translational research, have the drive to publish their results so that they can extrapolate their findings to the population. This begins with the preliminary step of deciding the topic to be studied, the subjects and the type of study design. In this context, the researcher must determine how many subjects would be required for the proposed study. Thus, the number of individuals to be included in the study, i.e., the sample size is an important consideration in the design of many clinical studies. The sample size determination should be based on the difference in the outcome between the two groups studied as in an analytical study, as well as on the accepted p value for statistical significance and the required statistical power to test a hypothesis. The accepted risk of type I error or alpha value, which by convention is set at the 0.05 level in biomedical research defines the cutoff point at which the p value obtained in the study is judged as significant or not. The power in clinical research is the likelihood of finding a statistically significant result when it exists and is typically set to >80%. This is necessary since the most rigorously executed studies may fail to answer the research question if the sample size is too small. Alternatively, a study with too large a sample size will be difficult and will result in waste of time and resources. Thus, the goal of sample size planning is to estimate an appropriate number of subjects for a given study design. This article describes the concepts in estimating the sample size.

  5. Advantages of infrared transflection micro spectroscopy and paraffin-embedded sample preparation for biological studies

    Science.gov (United States)

    Yao, Jie; Li, Qian; Zhou, Bo; Wang, Dan; Wu, Rie

    2018-04-01

    Fourier-Transform Infrared micro-spectroscopy is an excellent method for biological analyses. In this paper, series metal coating films on ITO glass were prepared by the electrochemical method and the different thicknesses of paraffin embedding rat's brain tissue on the substrates were studied by IR micro-spetroscopy in attenuated total reflection (ATR) mode and transflection mode respectively. The Co-Ni-Cu alloy coating film with low cost is good reflection substrates for the IR analysis. The infrared microscopic transflection mode needs not to touch the sample at all and can get the IR spectra with higher signal to noise ratios. The Paraffin-embedding method allows tissues to be stored for a long time for re-analysis to ensure the traceability of the sample. Also it isolates the sample from the metal and avoids the interaction of biological tissue with the metals. The best thickness of the tissues is 4 μm.

  6. Water quality monitoring: A comparative case study of municipal and Curtin Sarawak's lake samples

    International Nuclear Information System (INIS)

    Kumar, A Anand; Prabakaran, K; Nagarajan, R; Jaison, J; Chan, Y S

    2016-01-01

    In this study, particle size distribution and zeta potential of the suspended particles in municipal water and lake surface water of Curtin Sarawak's lake were compared and the samples were analysed using dynamic light scattering method. High concentration of suspended particles affects the water quality as well as suppresses the aquatic photosynthetic systems. A new approach has been carried out in the current work to determine the particle size distribution and zeta potential of the suspended particles present in the water samples. The results for the lake samples showed that the particle size ranges from 180nm to 1345nm and the zeta potential values ranges from -8.58 mV to -26.1 mV. High zeta potential value was observed in the surface water samples of Curtin Sarawak's lake compared to the municipal water. The zeta potential values represent that the suspended particles are stable and chances of agglomeration is lower in lake water samples. Moreover, the effects of physico-chemical parameters on zeta potential of the water samples were also discussed. (paper)

  7. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    International Nuclear Information System (INIS)

    Barnett, J.M.

    2008-01-01

    Since the mid-1980s the Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as a correction factor for the self absorption of activity of particulate radioactive air samples. More recently, an effort was made to evaluate the current particulate radioactive air sample filters (Versapor(reg s ign) 3000) used at PNNL for self absorption effects. There were two methods used in the study, (1) to compare the radioactivity concentration by direct gas-flow proportional counting of the filter to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection and (2) to evaluate sample filters by high resolution visual/infrared microscopy to determine the depth of material loading on or in the filter fiber material. Sixty samples were selected from the archive for acid digestion in the first method and about 30 samples were selected for high resolution visual/infrared microscopy. Mass loading effects were also considered. From the sample filter analysis, large error is associated with the average self absorption factor, however, when the data is compared directly one-to-one, statistically, there appears to be good correlation between the two analytical methods. The mass loading of filters evaluated was <0.2 mg cm-2 and was also compared against other published results. The microscopy analysis shows the sample material remains on the top of the filter paper and does not imbed into the filter media. Results of the microscopy evaluation lead to the conclusion that there is not a mechanism for significant self absorption. The overall conclusion is that self-absorption is not a significant factor in the analysis of filters used at PNNL for radioactive air stack sampling of radionuclide particulates and that an applied correction factor is conservative in determining overall sample activity. A new self absorption factor of 1.0 is recommended

  8. Scanning Ion Conductance Microscopy for Studying Biological Samples

    Directory of Open Access Journals (Sweden)

    Irmgard D. Dietzel

    2012-11-01

    Full Text Available Scanning ion conductance microscopy (SICM is a scanning probe technique that utilizes the increase in access resistance that occurs if an electrolyte filled glass micro-pipette is approached towards a poorly conducting surface. Since an increase in resistance can be monitored before the physical contact between scanning probe tip and sample, this technique is particularly useful to investigate the topography of delicate samples such as living cells. SICM has shown its potential in various applications such as high resolution and long-time imaging of living cells or the determination of local changes in cellular volume. Furthermore, SICM has been combined with various techniques such as fluorescence microscopy or patch clamping to reveal localized information about proteins or protein functions. This review details the various advantages and pitfalls of SICM and provides an overview of the recent developments and applications of SICM in biological imaging. Furthermore, we show that in principle, a combination of SICM and ion selective micro-electrodes enables one to monitor the local ion activity surrounding a living cell.

  9. Clinical syndromes, personality and recovery from stress: A study in occupational samples

    Directory of Open Access Journals (Sweden)

    José Miguel Rodríguez Molina

    2012-12-01

    Full Text Available Introduction. Stress manifests itself with different intensity and effects on different people. In many cases it leads to serious health problems or may worsen the prognosis of certain diseases. Stress has been linked to many conditions such as cancer, cardiovascular diseases and infectious diseases. The workplace can be a source of chronic stress. Many variables have been described that allegedly modulate stress response. Aim. To rank the relationship between some of these variables. A model is presented in this study whereby psychopathological personality traits should be related to one of those modulating variables and thus, with the subject's ability to recover from stress. Design. A cross-sectional descriptive design was used. Participants. The sample consisted of 108 volunteers: 15 drivers of Madrid city buses, 44 Iberia flight attendants and 49 waiters in bars in the Community of Madrid. Only 4 bus drivers refused to participate. All flight attendants and waiters consented to be included in the study. Intervention. Tests RESTQ-WORK of Kallus and Jiménez and MCMI of Millon were applied to a sample of 108 workers (bus drivers, bar tender and flight attendants. Outcomes. The hypothesis was verified through Hierarchical Multiple Regression Analysis for each dependant variable.

  10. [Stress and night eating syndrome: a comparison study between a sample of psychiatric outpatients and healthy subjects].

    Science.gov (United States)

    Pacitti, Francesca; Maraone, Annalisa; Zazzara, Francesca; Biondi, Massimo; Caredda, Maria

    2011-01-01

    The Night Eating Syndrome (NES) is a disorder characterized by the clinical features of morning anorexia, evening hyperphagia, and insomnia with awakenings followed by nocturnal food ingestion. The core clinical feature appears to be a delay in the circadian timing of food intake. The diagnosis and early treatment of NES may represent an important means of prevention for obesity. Aims. The aim of the present study was to determine the vulnerability to develop NES between a clinical sample of patients with psychiatric disorders and a non clinical sample. We investigated a possible relation between stress and a dysfunctional eating behaviors as NES. Methods. The Night Eating Questionnaire (NEQ) has been administered to 147 psychiatric outpatients and to 531 subjects attending the University of L'Aquila. The NEQ is a questionnaire used to evaluate the prevalence of NES. The sample has been also evaluated through the Stress-related Vulnerability Scale (SVS) to measure both perceived stress and social support. Results. The 8.2% of patients scored above the diagnostic cut-off of the NEQ, compared to the 2.1% in the sample of healthy subjects. The majority of patients who had shown NEQ>25 had a diagnosis of major depressive disorder (MDD). The total scores on the NEQ were strongly associated with the SVS total score and especially with the "lack of social support" subscale. Conclusions. This study shows the increased vulnerability of NES in the sample of psychiatric patients compared to the sample of healthy subjects. The study further confirms the strong association between perceived stress, social support, altered eating behaviors and obesity.

  11. Jenis Sample: Keuntungan dan Kerugiannya

    OpenAIRE

    Suprapto, Agus

    1994-01-01

    Sample is a part of a population that are used in a study for purposes of making estimation about the nature of the total population that is obtained with sampling technic. Sampling technic is more adventagous than cencus because it can reduce cost, time, and it can gather deeper information and more accurate data. It is useful to distinguish two major types of sampling technics. First, Prob bility sampling i.e. simple random sampling. Second, Non Probability sampling i.e. systematic sam­plin...

  12. Waste classification sampling plan

    International Nuclear Information System (INIS)

    Landsman, S.D.

    1998-01-01

    The purpose of this sampling is to explain the method used to collect and analyze data necessary to verify and/or determine the radionuclide content of the B-Cell decontamination and decommissioning waste stream so that the correct waste classification for the waste stream can be made, and to collect samples for studies of decontamination methods that could be used to remove fixed contamination present on the waste. The scope of this plan is to establish the technical basis for collecting samples and compiling quantitative data on the radioactive constituents present in waste generated during deactivation activities in B-Cell. Sampling and radioisotopic analysis will be performed on the fixed layers of contamination present on structural material and internal surfaces of process piping and tanks. In addition, dose rate measurements on existing waste material will be performed to determine the fraction of dose rate attributable to both removable and fixed contamination. Samples will also be collected to support studies of decontamination methods that are effective in removing the fixed contamination present on the waste. Sampling performed under this plan will meet criteria established in BNF-2596, Data Quality Objectives for the B-Cell Waste Stream Classification Sampling, J. M. Barnett, May 1998

  13. A Web-based Simulator for Sample Size and Power Estimation in Animal Carcinogenicity Studies

    Directory of Open Access Journals (Sweden)

    Hojin Moon

    2002-12-01

    Full Text Available A Web-based statistical tool for sample size and power estimation in animal carcinogenicity studies is presented in this paper. It can be used to provide a design with sufficient power for detecting a dose-related trend in the occurrence of a tumor of interest when competing risks are present. The tumors of interest typically are occult tumors for which the time to tumor onset is not directly observable. It is applicable to rodent tumorigenicity assays that have either a single terminal sacrifice or multiple (interval sacrifices. The design is achieved by varying sample size per group, number of sacrifices, number of sacrificed animals at each interval, if any, and scheduled time points for sacrifice. Monte Carlo simulation is carried out in this tool to simulate experiments of rodent bioassays because no closed-form solution is available. It takes design parameters for sample size and power estimation as inputs through the World Wide Web. The core program is written in C and executed in the background. It communicates with the Web front end via a Component Object Model interface passing an Extensible Markup Language string. The proposed statistical tool is illustrated with an animal study in lung cancer prevention research.

  14. Study on elemental analysis of metal and ceramic samples by using laser ablation ion trap mass spectrometry(LAITMS)

    International Nuclear Information System (INIS)

    Cha, Hyung Ki; Park, Hyun Kook; Lee, Sang Chun; SONG, Kyu Seok

    2002-01-01

    Laser ablation ion trap mass spectrometry (LAITMS) was developed for the analysis of metal and ceramic samples. For this study, XeCl excimer laser (308 nm) was used for ablating the samples and ITMS was used as a detector. Samples were introduced from outside of a ring electrode and this way of sample introduction was very effective for solid samples when laser ablation was employed. Helium gas was used as a buffer gas, and its effect on sensitivity and some parameters (buffer gas pressure, ion storage time, and cut-off RF voltage) were studied. The optimized conditions were 1 x 10 - 4 Torr of buffer gas pressure, 100 ms of ion storage time and 1150 V p- p of cut-off RF voltage. From that results, copper (Cu) and molybdenum(Mo) metals were tested with LAITMS and the mass spectra of these pure metals were compared with the natural abundance of isotope ratio. We also examined ceramic samples (Al 2 O 3 , ZrO 2 ) and represented the result of elements analysis

  15. Using Lagrangian sampling to study water quality during downstream transport in the San Luis Drain, California, USA

    Science.gov (United States)

    Volkmar, E.C.; Dahlgren, R.A.; Stringfellow, W.T.; Henson, S.S.; Borglin, S.E.; Kendall, C.; Van Nieuwenhuyse, E. E.

    2011-01-01

    To investigate the mechanism for diel (24h) changes commonly observed at fixed sampling locations and how these diel changes relate to downstream transport in hypereutrophic surface waters, we studied a parcel of agricultural drainage water as it traveled for 84h in a concrete-lined channel having no additional water inputs or outputs. Algal fluorescence, dissolved oxygen, temperature, pH, conductivity, and turbidity were measured every 30min. Grab samples were collected every 2h for water quality analyses, including nutrients, suspended sediment, and chlorophyll/pheophytin. Strong diel patterns were observed for dissolved oxygen, pH, and temperature within the parcel of water. In contrast, algal pigments and nitrate did not exhibit diel patterns within the parcel of water, but did exhibit strong diel patterns for samples collected at a fixed sampling location. The diel patterns observed at fixed sampling locations for these constituents can be attributed to algal growth during the day and downstream transport (washout) of algae at night. Algal pigments showed a rapid daytime increase during the first 48h followed by a general decrease for the remainder of the study, possibly due to sedimentation and photobleaching. Algal growth (primarily diatoms) was apparent each day during the study, as measured by increasing dissolved oxygen concentrations, despite low phosphate concentrations (<0.01mgL-1). ?? 2011 Elsevier B.V.

  16. Experimental and Sampling Design for the INL-2 Sample Collection Operational Test

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Matzke, Brett D.

    2009-02-16

    , sample extraction, and analytical methods to be used in the INL-2 study. For each of the five test events, the specified floor of the INL building will be contaminated with BG using a point-release device located in the room specified in the experimental design. Then quality control (QC), reference material coupon (RMC), judgmental, and probabilistic samples will be collected according to the sampling plan for each test event. Judgmental samples will be selected based on professional judgment and prior information. Probabilistic samples were selected with a random aspect and in sufficient numbers to provide desired confidence for detecting contamination or clearing uncontaminated (or decontaminated) areas. Following sample collection for a given test event, the INL building will be decontaminated. For possibly contaminated areas, the numbers of probabilistic samples were chosen to provide 95% confidence of detecting contaminated areas of specified sizes. For rooms that may be uncontaminated following a contamination event, or for whole floors after decontamination, the numbers of judgmental and probabilistic samples were chosen using the CJR approach. The numbers of samples were chosen to support making X%/Y% clearance statements with X = 95% or 99% and Y = 96% or 97%. The experimental and sampling design also provides for making X%/Y% clearance statements using only probabilistic samples. For each test event, the numbers of characterization and clearance samples were selected within limits based on operational considerations while still maintaining high confidence for detection and clearance aspects. The sampling design for all five test events contains 2085 samples, with 1142 after contamination and 943 after decontamination. These numbers include QC, RMC, judgmental, and probabilistic samples. The experimental and sampling design specified in this report provides a good statistical foundation for achieving the objectives of the INL-2 study.

  17. Choice of infusion-sampling mode for tracer studies of free fatty acid metabolism

    International Nuclear Information System (INIS)

    Jensen, M.D.; Rogers, P.J.; Ellman, M.G.; Miles, J.M.

    1988-01-01

    To determine the preferred infusion-sampling mode for isotopic studies of free fatty acid (FFA) metabolism, tracer [( 14 C]palmitate) was infused into the left ventricle of five anesthetized dogs, and tracee ([ 3 H]palmitate) was infused into three separate peripheral veins of each dog. The [ 14 C]palmitate specific activity (SA) was lower in mixed venous than arterial blood, and [ 3 H]palmitate SA was equal in both sites. The actual infusion rate of [ 3 H]palmitate [2.15 +/- 0.31 X 10(5) disintegrations/min (dpm).kg-1.min-1] could be accurately predicted (2.14 +/- 0.32 X 10(5) dpm.kg-1.min-1) using the known [ 14 C]palmitate infusion rate and the arterial plasma [ 14 C]-to-[ 3 H]palmitate ratio. In contrast, the mixed venous [ 14 C]-to-[ 3 H]palmitate ratio resulted in overestimates (P less than 0.05) of the actual [ 3 H]palmitate infusion rate. In summary, venous tracer infusion with arterial blood sampling for FFA tracer studies provides the most accurate estimates of tracee rate of appearance

  18. Study on different pre-treatment procedures for metal determination in Orujo spirit samples by ICP-AES

    International Nuclear Information System (INIS)

    Barciela, Julia; Vilar, Manuela; Garcia-Martin, Sagrario; Pena, Rosa M.; Herrero, Carlos

    2008-01-01

    In this work several pre-treatment methods were studied for metal (Na, K, Mg, Cu and Ca) determination in Orujo spirit samples using inductively coupled plasma atomic emission spectrometry (ICP-AES). Dilution, digestion, evaporation, and cryogenic desolvatation techniques were comparatively evaluated. Because of their analytical characteristics, digestion and evaporation with nitrogen current were found to be appropriate procedures for the determination of metals in alcoholic spirit samples. Yet, if simplicity and application time are to be considered, the latter-evaporation in a water bath with a nitrogen current-stands out as the optimum procedure for any further determinations in Orujo samples by ICP-AES. Low detection levels and wide linear ranges (sufficient to determine these metals in the samples studied) were achieved for each metal. The recoveries (in the 97.5-100.5% range) and the precision (R.S.D. lower than 5.6%) obtained were also satisfactory. The selected procedure was applied to determine the content of metals in 80 representative Galician Orujo spirit samples with and without a Certified Brand of Origin (CBO) which had been produced using different distillation systems. The metal concentrations ranged between 0.37 and 79.7 mg L -1 for Na, -1 for K, 0.02-4.83 mg L -1 for Mg content, -1 for Cu and 0.03-13.10 mg L -1 for Ca

  19. Vaccination and blood sampling acceptability during Ramadan fasting month: A cross-sectional study in Conakry, Guinea.

    Science.gov (United States)

    Peiffer-Smadja, Nathan; Ouedraogo, Ramatou; D'Ortenzio, Eric; Cissé, Papa Ndiaga; Zeggani, Zahra; Beavogui, Abdoul Habib; Faye, Sylvain Landry; Le Marcis, Frédéric; Yazdanpanah, Yazdan; Nguyen, Vinh-Kim

    2017-05-02

    There are few data on the acceptability of vaccination or blood sampling during Ramadan fasting month in Muslim countries. This could impact vaccination campaigns, clinical trials or healthcare during Ramadan. Using a semi-structured questionnaire, we conducted a cross-sectional study on 201 practising Muslims and 10 religious leaders in Conakry, Guinea in the wake of the recent epidemic Ebola epidemic. Acceptability of vaccination and blood sampling during Ramadan were investigated as well as reasons for refusal. Vaccination was judged acceptable during Ramadan by 46% (93/201, 95% CI 0.40-0.53) of practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) of religious leaders (p=0.11). Blood sampling was judged acceptable during Ramadan by 54% (108/201, 95% CI 0.47-0.60) of practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) of religious leaders (p=0.19). The percentage of participants that judged both blood sampling and vaccination acceptable during Ramadan was 40% (81/201, 95% CI 0.34-0.47) for practising Muslims versus 80% (8/10, 95% CI 0.49-0.94) for religious leaders (p=0.048). The most common reasons for refusal of vaccination or blood sampling were that nothing should enter or leave the body during Ramadan (43%), that adverse events could lead to breaking the fast (32%), that blood should not be seen during Ramadan (9%) and that the Quran explicitly forbids it (9%). Although most Muslims leaders and scientists consider that injections including immunization and blood sampling should be authorized during Ramadan, many Muslims in our study judged vaccination or blood sampling unacceptable when fasting. Widely available recommendations on healthcare during Ramadan would be useful to inform Muslims. Copyright © 2017. Published by Elsevier Ltd.

  20. Optimum sample size allocation to minimize cost or maximize power for the two-sample trimmed mean test.

    Science.gov (United States)

    Guo, Jiin-Huarng; Luh, Wei-Ming

    2009-05-01

    When planning a study, sample size determination is one of the most important tasks facing the researcher. The size will depend on the purpose of the study, the cost limitations, and the nature of the data. By specifying the standard deviation ratio and/or the sample size ratio, the present study considers the problem of heterogeneous variances and non-normality for Yuen's two-group test and develops sample size formulas to minimize the total cost or maximize the power of the test. For a given power, the sample size allocation ratio can be manipulated so that the proposed formulas can minimize the total cost, the total sample size, or the sum of total sample size and total cost. On the other hand, for a given total cost, the optimum sample size allocation ratio can maximize the statistical power of the test. After the sample size is determined, the present simulation applies Yuen's test to the sample generated, and then the procedure is validated in terms of Type I errors and power. Simulation results show that the proposed formulas can control Type I errors and achieve the desired power under the various conditions specified. Finally, the implications for determining sample sizes in experimental studies and future research are discussed.

  1. Sampling methods

    International Nuclear Information System (INIS)

    Loughran, R.J.; Wallbrink, P.J.; Walling, D.E.; Appleby, P.G.

    2002-01-01

    Methods for the collection of soil samples to determine levels of 137 Cs and other fallout radionuclides, such as excess 210 Pb and 7 Be, will depend on the purposes (aims) of the project, site and soil characteristics, analytical capacity, the total number of samples that can be analysed and the sample mass required. The latter two will depend partly on detector type and capabilities. A variety of field methods have been developed for different field conditions and circumstances over the past twenty years, many of them inherited or adapted from soil science and sedimentology. The use of them inherited or adapted from soil science and sedimentology. The use of 137 Cs in erosion studies has been widely developed, while the application of fallout 210 Pb and 7 Be is still developing. Although it is possible to measure these nuclides simultaneously, it is common for experiments to designed around the use of 137 Cs along. Caesium studies typically involve comparison of the inventories found at eroded or sedimentation sites with that of a 'reference' site. An accurate characterization of the depth distribution of these fallout nuclides is often required in order to apply and/or calibrate the conversion models. However, depending on the tracer involved, the depth distribution, and thus the sampling resolution required to define it, differs. For example, a depth resolution of 1 cm is often adequate when using 137 Cs. However, fallout 210 Pb and 7 Be commonly has very strong surface maxima that decrease exponentially with depth, and fine depth increments are required at or close to the soil surface. Consequently, different depth incremental sampling methods are required when using different fallout radionuclides. Geomorphic investigations also frequently require determination of the depth-distribution of fallout nuclides on slopes and depositional sites as well as their total inventories

  2. Daily Stressful Experiences Precede But Do Not Succeed Depressive Symptoms : Results from a Longitudinal Experience Sampling Study

    NARCIS (Netherlands)

    Brose, Annette; Wichers, Marieke; Kuppens, Peter

    This study investigates the proposition that micro-level experiences in the realm of stress (e.g., daily stress exposure) are among the building blocks of maladjustment, in particular, depression. Data were collected with experience sampling methods and in the lab. A sample of 202 students who had

  3. Primary studies on particle recovery of swipe samples for nuclear safeguards

    International Nuclear Information System (INIS)

    Fan Wang; Yan Chen; Yong-gang Zhao; Yan Zhang; Tong-xing Wang; Jing-huai Li; Zhi-yuan Chang; Hai-ping Cui

    2013-01-01

    Environmental sampling plays a significant role in nuclear safeguards. Isotopic ratio in uranium-bearing particles from swipe samples provides important information for detecting undeclared activities. Particle recovery which is the primary step of particle analysis, would affect the following analysis. The particle recovery efficiency of ultrasoneration recovery and vacuum suction-impact recovery were measured by alpha spectrometer with standard particles produced via aerosol spray pyrolysis method. The conditions of ultrasoneration were optimized and both recovery methods were evaluated. Finally, a procedure of particle recovery for unknown swipe samples was set up. (author)

  4. Comparative Study of the Effect of Sample Pretreatment and Extraction on the Determination of Flavonoids from Lemon (Citrus limon)

    Science.gov (United States)

    Ledesma-Escobar, Carlos A.; Priego-Capote, Feliciano; Luque de Castro, María D.

    2016-01-01

    Background Flavonoids have shown to exert multiple beneficial effects on human health, being also appreciated by both food and pharmaceutical industries. Citrus fruits are a key source of flavonoids, thus promoting studies to obtain them. Characteristics of these studies are the discrepancies among sample pretreatments and among extraction methods, and also the scant number of comparative studies developed so far. Objective Evaluate the effect of both the sample pretreatment and the extraction method on the profile of flavonoids isolated from lemon. Results Extracts from fresh, lyophilized and air-dried samples obtained by shaking extraction (SE), ultrasound-assisted extraction (USAE), microwave-assisted extraction (MAE) and superheated liquid extraction (SHLE) were analyzed by LC–QTOF MS/MS, and 32 flavonoids were tentatively identified using MS/MS information. ANOVA applied to the data from fresh and dehydrated samples and from extraction by the different methods revealed that 26 and 32 flavonoids, respectively, were significant (p≤0.01). The pairwise comparison (Tukey HSD; p≤0.01) showed that lyophilized samples are more different from fresh samples than from air-dried samples; also, principal component analysis (PCA) showed a clear discrimination among sample pretreatment strategies and suggested that such differences are mainly created by the abundance of major flavonoids. On the other hand, pairwise comparison of extraction methods revealed that USAE and MAE provided quite similar extracts, being SHLE extracts different from the other two. In this case, PCA showed a clear discrimination among extraction methods, and their position in the scores plot suggests a lower abundance of flavonoids in the extracts from SHLE. In the two PCA the loadings plots revealed a trend to forming groups according to flavonoid aglycones. Conclusions The present study shows clear discrimination caused by both sample pretreatments and extraction methods. Under the studied

  5. Estimating sample size for landscape-scale mark-recapture studies of North American migratory tree bats

    Science.gov (United States)

    Ellison, Laura E.; Lukacs, Paul M.

    2014-01-01

    Concern for migratory tree-roosting bats in North America has grown because of possible population declines from wind energy development. This concern has driven interest in estimating population-level changes. Mark-recapture methodology is one possible analytical framework for assessing bat population changes, but sample size requirements to produce reliable estimates have not been estimated. To illustrate the sample sizes necessary for a mark-recapture-based monitoring program we conducted power analyses using a statistical model that allows reencounters of live and dead marked individuals. We ran 1,000 simulations for each of five broad sample size categories in a Burnham joint model, and then compared the proportion of simulations in which 95% confidence intervals overlapped between and among years for a 4-year study. Additionally, we conducted sensitivity analyses of sample size to various capture probabilities and recovery probabilities. More than 50,000 individuals per year would need to be captured and released to accurately determine 10% and 15% declines in annual survival. To detect more dramatic declines of 33% or 50% survival over four years, then sample sizes of 25,000 or 10,000 per year, respectively, would be sufficient. Sensitivity analyses reveal that increasing recovery of dead marked individuals may be more valuable than increasing capture probability of marked individuals. Because of the extraordinary effort that would be required, we advise caution should such a mark-recapture effort be initiated because of the difficulty in attaining reliable estimates. We make recommendations for what techniques show the most promise for mark-recapture studies of bats because some techniques violate the assumptions of mark-recapture methodology when used to mark bats.

  6. Present state of tandem accelerator analysis facility of the National Institute for Environmental Studies. 2. Sample preparation

    Energy Technology Data Exchange (ETDEWEB)

    Kumamoto, Yuichiro; Shibata, Yasuyuki; Kume, Hiroshi; Tanaka, Atsushi; Yoneda, Minoru; Uehiro, Takashi; Morita, Masatoshi [National Inst. for Environmental Studies, Tsukuba, Ibaraki (Japan)

    1996-12-01

    An AMS exclusive apparatus constituted for a center of 5 MV of tandem accelerator (15SDH-2) was introduced to the National Institute for Environmental Studies on September, 1995. The incidental part of the apparatus is constituted by combining negative ion source for solid sample (MC-SNICS) with successive incidental system and combining negative ion source for gas sample (MGF-SNICS) with simultaneous incidental system. In this study, preparation of graphite target for testing of {sup 14}C at a temporary aim of supplying solid sample for MC-SNICS necessary to modulate the apparatus has been conducted. As a result, it was found that most of isotope fractionation on graphite formation from oxalic acid could be neglected. However, as it was said that efficiency of the graphite formation was largely changed with mixing with traced volume of gas such as sulfur dioxide and so on, future presumption is laid at investigation of such isotope fractionation effect on some samples except oxalic acid. In order to conduct contamination evaluation of 14-C at sample preparation, graphite preparation from organic matters and carbon dioxide obtained the fossil fuels without containing 14-C are exchanged in present research. (G.K.)

  7. Sample Length Affects the Reliability of Language Sample Measures in 3-Year-Olds: Evidence from Parent-Elicited Conversational Samples

    Science.gov (United States)

    Guo, Ling-Yu; Eisenberg, Sarita

    2015-01-01

    Purpose: The goal of this study was to investigate the extent to which sample length affected the reliability of total number of words (TNW), number of different words (NDW), and mean length of C-units in morphemes (MLCUm) in parent-elicited conversational samples for 3-year-olds. Method: Participants were sixty 3-year-olds. A 22-min language…

  8. Development of SYVAC sampling techniques

    International Nuclear Information System (INIS)

    Prust, J.O.; Dalrymple, G.J.

    1985-04-01

    This report describes the requirements of a sampling scheme for use with the SYVAC radiological assessment model. The constraints on the number of samples that may be taken is considered. The conclusions from earlier studies using the deterministic generator sampling scheme are summarised. The method of Importance Sampling and a High Dose algorithm, which are designed to preferentially sample in the high dose region of the parameter space, are reviewed in the light of experience gained from earlier studies and the requirements of a site assessment and sensitivity analyses. In addition the use of an alternative numerical integration method for estimating risk is discussed. It is recommended that the method of Importance Sampling is developed and tested for use with SYVAC. An alternative numerical integration method is not recommended for investigation at this stage but should be the subject of future work. (author)

  9. Assessment of fracture risk: value of random population-based samples--the Geelong Osteoporosis Study.

    Science.gov (United States)

    Henry, M J; Pasco, J A; Seeman, E; Nicholson, G C; Sanders, K M; Kotowicz, M A

    2001-01-01

    Fracture risk is determined by bone mineral density (BMD). The T-score, a measure of fracture risk, is the position of an individual's BMD in relation to a reference range. The aim of this study was to determine the magnitude of change in the T-score when different sampling techniques were used to produce the reference range. Reference ranges were derived from three samples, drawn from the same region: (1) an age-stratified population-based random sample, (2) unselected volunteers, and (3) a selected healthy subset of the population-based sample with no diseases or drugs known to affect bone. T-scores were calculated using the three reference ranges for a cohort of women who had sustained a fracture and as a group had a low mean BMD (ages 35-72 yr; n = 484). For most comparisons, the T-scores for the fracture cohort were more negative using the population reference range. The difference in T-scores reached 1.0 SD. The proportion of the fracture cohort classified as having osteoporosis at the spine was 26, 14, and 23% when the population, volunteer, and healthy reference ranges were applied, respectively. The use of inappropriate reference ranges results in substantial changes to T-scores and may lead to inappropriate management.

  10. Matrix effect study in the determination of linear alkylbenzene sulfonates in sewage sludge samples.

    Science.gov (United States)

    Cantarero, Samuel; Zafra-Gómez, Alberto; Ballesteros, Oscar; Navalón, Alberto; Vílchez, José L; Verge, Coral; De Ferrer, Juan A

    2011-04-01

    We propose a study of the matrix effect in the determination of linear alkylbenzene sulfonates (LAS) in sewage sludge samples. First, a rapid, selective and sensitive method is proposed. The method involves two stages: the extraction of the compound from the samples and analysis by liquid chromatography with fluorescence detection (LC-FLD). Three different techniques of extraction (microwave-assisted extraction, Soxhlet, and ultrasounds) were compared, and microwave-assisted extraction was selected as the best suited for our purpose. Microwave-assisted extraction allows reducing the extraction time (25 min compared with 12 h for conventional Soxhlet extraction) and solvent waste (25 ml of methanol compared with 200 ml for Soxhlet or more than 50 ml for the ultrasonic procedure). Absence of matrix effect was evaluated with two standards (2ØC(8:0) and 2ØC(16:0) ) that are not commercial; therefore, neither of them was detected in sewage sludge samples and they showed similar environmental behavior (adsorption and precipitation) to LAS (C(11:0) -C(13.0) ), which allow us to evaluate the matrix effect. Validation was carried out by a recovery assay, and the method was applied to samples from different sources; therefore, they had different compositions. Copyright © 2011 SETAC.

  11. Mass Balance Model, A study of contamination effects in AMS 14C sample analysis

    NARCIS (Netherlands)

    Prokopiou, Markella

    2010-01-01

    In this training thesis a background correction analysis, also known as mass balance model, was implemented to study the contamination effects in AMS 14C sample processing. A variety of backgrounds and standards with sizes ranging from 50 μg C to 1500 μg

  12. The Lunar Sample Compendium

    Science.gov (United States)

    Meyer, Charles

    2009-01-01

    The Lunar Sample Compendium is a succinct summary of the data obtained from 40 years of study of Apollo and Luna samples of the Moon. Basic petrographic, chemical and age information is compiled, sample-by-sample, in the form of an advanced catalog in order to provide a basic description of each sample. The LSC can be found online using Google. The initial allocation of lunar samples was done sparingly, because it was realized that scientific techniques would improve over the years and new questions would be formulated. The LSC is important because it enables scientists to select samples within the context of the work that has already been done and facilitates better review of proposed allocations. It also provides back up material for public displays, captures information found only in abstracts, grey literature and curatorial databases and serves as a ready access to the now-vast scientific literature.

  13. Study on different pre-treatment procedures for metal determination in Orujo spirit samples by ICP-AES

    Energy Technology Data Exchange (ETDEWEB)

    Barciela, Julia; Vilar, Manuela; Garcia-Martin, Sagrario [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain); Pena, Rosa M. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain)], E-mail: qarosa@lugo.usc.es; Herrero, Carlos [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain)], E-mail: cherrero@lugo.usc.es

    2008-10-17

    In this work several pre-treatment methods were studied for metal (Na, K, Mg, Cu and Ca) determination in Orujo spirit samples using inductively coupled plasma atomic emission spectrometry (ICP-AES). Dilution, digestion, evaporation, and cryogenic desolvatation techniques were comparatively evaluated. Because of their analytical characteristics, digestion and evaporation with nitrogen current were found to be appropriate procedures for the determination of metals in alcoholic spirit samples. Yet, if simplicity and application time are to be considered, the latter-evaporation in a water bath with a nitrogen current-stands out as the optimum procedure for any further determinations in Orujo samples by ICP-AES. Low detection levels and wide linear ranges (sufficient to determine these metals in the samples studied) were achieved for each metal. The recoveries (in the 97.5-100.5% range) and the precision (R.S.D. lower than 5.6%) obtained were also satisfactory. The selected procedure was applied to determine the content of metals in 80 representative Galician Orujo spirit samples with and without a Certified Brand of Origin (CBO) which had been produced using different distillation systems. The metal concentrations ranged between 0.37 and 79.7 mg L{sup -1} for Na,

  14. Detecting spatial structures in throughfall data: The effect of extent, sample size, sampling design, and variogram estimation method

    Science.gov (United States)

    Voss, Sebastian; Zimmermann, Beate; Zimmermann, Alexander

    2016-09-01

    In the last decades, an increasing number of studies analyzed spatial patterns in throughfall by means of variograms. The estimation of the variogram from sample data requires an appropriate sampling scheme: most importantly, a large sample and a layout of sampling locations that often has to serve both variogram estimation and geostatistical prediction. While some recommendations on these aspects exist, they focus on Gaussian data and high ratios of the variogram range to the extent of the study area. However, many hydrological data, and throughfall data in particular, do not follow a Gaussian distribution. In this study, we examined the effect of extent, sample size, sampling design, and calculation method on variogram estimation of throughfall data. For our investigation, we first generated non-Gaussian random fields based on throughfall data with large outliers. Subsequently, we sampled the fields with three extents (plots with edge lengths of 25 m, 50 m, and 100 m), four common sampling designs (two grid-based layouts, transect and random sampling) and five sample sizes (50, 100, 150, 200, 400). We then estimated the variogram parameters by method-of-moments (non-robust and robust estimators) and residual maximum likelihood. Our key findings are threefold. First, the choice of the extent has a substantial influence on the estimation of the variogram. A comparatively small ratio of the extent to the correlation length is beneficial for variogram estimation. Second, a combination of a minimum sample size of 150, a design that ensures the sampling of small distances and variogram estimation by residual maximum likelihood offers a good compromise between accuracy and efficiency. Third, studies relying on method-of-moments based variogram estimation may have to employ at least 200 sampling points for reliable variogram estimates. These suggested sample sizes exceed the number recommended by studies dealing with Gaussian data by up to 100 %. Given that most previous

  15. Application of tandem accelerator mass spectrometor to the chronological study of archaeological samples on Ryukyu Islands

    International Nuclear Information System (INIS)

    Taira, Hatsuo; Higa, Kenichi; Nakai, Nobuyuki; Nakamura, Toshio.

    1987-01-01

    Along with the urbanization of rural areas on Ryukyu Islands, many shell mounds and pre-historic sites have been found in resent years. Chrological studies of shell samples from these mounds will lead to the better understanding of cultural background for the pre-historic human activities on the Ryukyu Islands. C-14 dating by beta counting is the common method to obtain the ages of the archaeological samples. It is, however, very limitted in obtaining the absolute ages by the above mehtod due to the large sample sizes required and time consuming. There are many newly obtained archaeological samples left unstudied in detail. The alternate is a method called Tandem Accelerator Mass Spectrometer (AMS) installed at Nagoya University, which is composed of the tandem type accelerator to measure very low concentration of C-14 in archaeological samples. The system has been designed particularly to measure the radio-carbon and has advantages of being small sample size and very little time consuming for C-14 measurement as compared with the beta counting. It is the aim of this work to apply the above AMS for obtaining the absolute ages of the archaeological samples. The results agreed well with those estimated by the Erthenware method (relative method of dating), which ranged from 500 to 6000 y.b.p. The results may be helpful for the chronological arrangement of the samples and for the understanding of pre-historical human activities on the Ryukyu Islands. (author)

  16. Generating samples for association studies based on HapMap data

    Directory of Open Access Journals (Sweden)

    Chen Yixuan

    2008-01-01

    Full Text Available Abstract Background With the completion of the HapMap project, a variety of computational algorithms and tools have been proposed for haplotype inference, tag SNP selection and genome-wide association studies. Simulated data are commonly used in evaluating these new developed approaches. In addition to simulations based on population models, empirical data generated by perturbing real data, has also been used because it may inherit specific properties from real data. However, there is no tool that is publicly available to generate large scale simulated variation data by taking into account knowledge from the HapMap project. Results A computer program (gs was developed to quickly generate a large number of samples based on real data that are useful for a variety of purposes, including evaluating methods for haplotype inference, tag SNP selection and association studies. Two approaches have been implemented to generate dense SNP haplotype/genotype data that share similar local linkage disequilibrium (LD patterns as those in human populations. The first approach takes haplotype pairs from samples as inputs, and the second approach takes patterns of haplotype block structures as inputs. Both quantitative and qualitative traits have been incorporated in the program. Phenotypes are generated based on a disease model, or based on the effect of a quantitative trait nucleotide, both of which can be specified by users. In addition to single-locus disease models, two-locus disease models have also been implemented that can incorporate any degree of epistasis. Users are allowed to specify all nine parameters in a 3 × 3 penetrance table. For several commonly used two-locus disease models, the program can automatically calculate penetrances based on the population prevalence and marginal effects of a disease that users can conveniently specify. Conclusion The program gs can effectively generate large scale genetic and phenotypic variation data that can be

  17. Correcting Classifiers for Sample Selection Bias in Two-Phase Case-Control Studies

    Science.gov (United States)

    Theis, Fabian J.

    2017-01-01

    Epidemiological studies often utilize stratified data in which rare outcomes or exposures are artificially enriched. This design can increase precision in association tests but distorts predictions when applying classifiers on nonstratified data. Several methods correct for this so-called sample selection bias, but their performance remains unclear especially for machine learning classifiers. With an emphasis on two-phase case-control studies, we aim to assess which corrections to perform in which setting and to obtain methods suitable for machine learning techniques, especially the random forest. We propose two new resampling-based methods to resemble the original data and covariance structure: stochastic inverse-probability oversampling and parametric inverse-probability bagging. We compare all techniques for the random forest and other classifiers, both theoretically and on simulated and real data. Empirical results show that the random forest profits from only the parametric inverse-probability bagging proposed by us. For other classifiers, correction is mostly advantageous, and methods perform uniformly. We discuss consequences of inappropriate distribution assumptions and reason for different behaviors between the random forest and other classifiers. In conclusion, we provide guidance for choosing correction methods when training classifiers on biased samples. For random forests, our method outperforms state-of-the-art procedures if distribution assumptions are roughly fulfilled. We provide our implementation in the R package sambia. PMID:29312464

  18. Stability of DREEM in a Sample of Medical Students: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Muhamad Saiful Bahri Yusoff

    2012-01-01

    Full Text Available Background. Over the last 15 year, DREEM was applied in various educational settings to appraise educational climate. So far, none of article reported its stability in Malaysian medical students. Objective. To determine stability of the DREEM to measure educational climate at different time and occasions using a sample of medical students. Methodology. A prospective cohort study was done on 196 first year medical students. It was administered to the medical students at four different intervals. The Cronbach's alpha and intraclass correlation analysis were applied to measure internal consistency and agreement level across the intervals. The analysis was done using SPSS 18. Result. A total of 186 (94.9% medical students responded completely to the DREEM inventory. The overall Cronbach's alpha value of the DREEM at the four measurements ranged between 0.91 and 0.94. The average Cronbach's alpha values of the five subscales ranged between 0.45 and 0.83. The ICC coefficient values for the DREEM total score was 0.67 and its subscales ranged between 0.51 and 0.62. Conclusion. This study supported satisfactory levels of stability and internal consistency of the DREEM to measure educational climate over multiple observations in a sample of Malaysian medical students. Continued research is required to optimise its psychometric credential across educational settings.

  19. A probable risk factor of female breast cancer: study on benign and malignant breast tissue samples.

    Science.gov (United States)

    Rehman, Sohaila; Husnain, Syed M

    2014-01-01

    The study reports enhanced Fe, Cu, and Zn contents in breast tissues, a probable risk factor of breast cancer in females. Forty-one formalin-fixed breast tissues were analyzed using atomic absorption spectrophotometry. Twenty malignant, six adjacent to malignant and 15 benign tissues samples were investigated. The malignant tissues samples were of grade 11 and type invasive ductal carcinoma. The quantitative comparison between the elemental levels measured in the two types of specimen (benign and malignant) tissues (removed after surgery) suggests significant elevation of these metals (Fe, Cu, and Zn) in the malignant tissue. The specimens were collected just after mastectomy of women aged 19 to 59 years from the hospitals of Islamabad and Rawalpindi, Pakistan. Most of the patients belong to urban areas of Pakistan. Findings of study depict that these elements have a promising role in the initiation and development of carcinoma as consistent pattern of elevation for Fe, Cu, and Zn was observed. The results showed the excessive accumulation of Fe (229 ± 121 mg/L) in malignant breast tissue samples of patients (p factor of breast cancer. In order to validate our method of analysis, certified reference material muscle tissue lyophilized (IAEA) MA-M-2/TM was analyzed for metal studied. Determined concentrations were quite in good agreement with certified levels. Asymmetric concentration distribution for Fe, Cu, and Zn was observed in both malignant and benign tissue samples.

  20. Lunar Sample Compendium

    Science.gov (United States)

    Meyer, Charles

    2005-01-01

    The purpose of the Lunar Sample Compendium will be to inform scientists, astronauts and the public about the various lunar samples that have been returned from the Moon. This Compendium will be organized rock by rock in the manor of a catalog, but will not be as comprehensive, nor as complete, as the various lunar sample catalogs that are available. Likewise, this Compendium will not duplicate the various excellent books and reviews on the subject of lunar samples (Cadogen 1981, Heiken et al. 1991, Papike et al. 1998, Warren 2003, Eugster 2003). However, it is thought that an online Compendium, such as this, will prove useful to scientists proposing to study individual lunar samples and should help provide backup information for lunar sample displays. This Compendium will allow easy access to the scientific literature by briefly summarizing the significant findings of each rock along with the documentation of where the detailed scientific data are to be found. In general, discussion and interpretation of the results is left to the formal reviews found in the scientific literature. An advantage of this Compendium will be that it can be updated, expanded and corrected as need be.

  1. Challenges in collecting clinical samples for research from pregnant women of South Asian origin: evidence from a UK study.

    Science.gov (United States)

    Neelotpol, Sharmind; Hay, Alastair W M; Jolly, A Jim; Woolridge, Mike W

    2016-08-31

    To recruit South Asian pregnant women, living in the UK, into a clinicoepidemiological study for the collection of lifestyle survey data and antenatal blood and to retain the women for the later collection of cord blood and meconium samples from their babies for biochemical analysis. A longitudinal study recruiting pregnant women of South Asian and Caucasian origin living in the UK. Recruitment of the participants, collection of clinical samples and survey data took place at the 2 sites within a single UK Northern Hospital Trust. Pregnant women of South Asian origin (study group, n=98) and of Caucasian origin (comparison group, n=38) living in Leeds, UK. Among the participants approached, 81% agreed to take part in the study while a 'direct approach' method was followed. The retention rate of the participants was a remarkable 93.4%. The main challenges in recruiting the ethnic minority participants were their cultural and religious conservativeness, language barrier, lack of interest and feeling of extra 'stress' in taking part in research. The chief investigator developed an innovative participant retention method, associated with the women's cultural and religious practices. The method proved useful in retaining the participants for about 5 months and in enabling successful collection of clinical samples from the same mother-baby pairs. The collection of clinical samples and lifestyle data exceeded the calculated sample size required to give the study sufficient power. The numbers of samples obtained were: maternal blood (n=171), cord blood (n=38), meconium (n=176), lifestyle questionnaire data (n=136) and postnatal records (n=136). Recruitment and retention of participants, according to the calculated sample size, ensured sufficient power and success for a clinicoepidemiological study. Results suggest that development of trust and confidence between the participant and the researcher is the key to the success of a clinical and epidemiological study involving

  2. Sample preparation composite and replicate strategy case studies for assay of solid oral drug products.

    Science.gov (United States)

    Nickerson, Beverly; Harrington, Brent; Li, Fasheng; Guo, Michele Xuemei

    2017-11-30

    Drug product assay is one of several tests required for new drug products to ensure the quality of the product at release and throughout the life cycle of the product. Drug product assay testing is typically performed by preparing a composite sample of multiple dosage units to obtain an assay value representative of the batch. In some cases replicate composite samples may be prepared and the reportable assay value is the average value of all the replicates. In previously published work by Harrington et al. (2014) [5], a sample preparation composite and replicate strategy for assay was developed to provide a systematic approach which accounts for variability due to the analytical method and dosage form with a standard error of the potency assay criteria based on compendia and regulatory requirements. In this work, this sample preparation composite and replicate strategy for assay is applied to several case studies to demonstrate the utility of this approach and its application at various stages of pharmaceutical drug product development. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. [Identification and sampling of people with migration background for epidemiological studies in Germany].

    Science.gov (United States)

    Reiss, K; Makarova, N; Spallek, J; Zeeb, H; Razum, O

    2013-06-01

    In 2009, 19.6% of the population of Germany either had migrated themselves or were the offspring of people with migration experience. Migrants differ from the autochthonous German population in terms of health status, health awareness and health behaviour. To further investigate the health situation of migrants in Germany, epidemiological studies are needed. Such studies can employ existing databases which provide detailed information on migration status. Otherwise, onomastic or toponomastic procedures can be applied to identify people with migration background. If migrants have to be recruited into an epidemiological study, this can be done register-based (e. g., data from registration offices or telephone lists), based on residential location (random-route or random-walk procedure), via snowball sampling (e. g., through key persons) or via settings (e. g., school entry examination). An oversampling of people with migration background is not sufficient to avoid systematic bias in the sample due to non-participation. Additional measures have to be taken to increase access and raise participation rates. Personal contacting, multilingual instruments, multilingual interviewers and extensive public relations increase access and willingness to participate. Empirical evidence on 'successful' recruitment strategies for studies with migrants is still lacking in epidemiology and health sciences in Germany. The choice of the recruitment strategy as well as the measures to raise accessibility and willingness to participate depend on the available resources, the research question and the specific migrant target group. © Georg Thieme Verlag KG Stuttgart · New York.

  4. The study of the sample size on the transverse magnetoresistance of bismuth nanowires

    International Nuclear Information System (INIS)

    Zare, M.; Layeghnejad, R.; Sadeghi, E.

    2012-01-01

    The effects of sample size on the galvanomagnetice properties of semimetal nanowires are theoretically investigated. Transverse magnetoresistance (TMR) ratios have been calculated within a Boltzmann Transport Equation (BTE) approach by specular reflection approximation. Temperature and radius dependence of the transverse magnetoresistance of cylindrical Bismuth nanowires are given. The obtained values are in good agreement with the experimental results, reported by Heremans et al. - Highlights: ► In this study effects of sample size on the galvanomagnetic properties of Bi. ► Nanowires were explained by Parrott theorem by solving the Boltzmann Transport Equation. ► Transverse magnetoresistance (TMR) ratios have been measured by specular reflection approximation. ► Temperature and radius dependence of the transverse magnetoresistance of cylindrical Bismuth nanowires are given. ► The obtained values are in good agreement with the experimental results, reported by Heremans et al.

  5. Study on the Effects of Sample Density on Gamma Spectrometry System Measurement Efficiency at Radiochemistry and Environment Laboratory

    International Nuclear Information System (INIS)

    Wo, Y.M.; Dainee Nor Fardzila Ahmad Tugi; Khairul Nizam Razali

    2015-01-01

    The effects of sample density on the measurement efficiency of the gamma spectrometry system were studied by using four sets multi nuclide standard sources of various densities between 0.3 - 1.4 g/ ml. The study was conducted on seven unit 25 % coaxial HPGe detector gamma spectrometry systems in Radiochemistry and Environment Laboratory (RAS). Difference on efficiency against gamma emitting radionuclides energy and measurement systems were compared and discussed. Correction factor for self absorption caused by difference in sample matrix density of the gamma systems were estimated. The correction factors are to be used in quantification of radionuclides concentration in various densities of service and research samples in RAS. (author)

  6. Chemical and geotechnical analyses of soil samples from Olkiluoto for studies on sorption in soils

    International Nuclear Information System (INIS)

    Lusa, M.; Aemmaelae, K.; Hakanen, M.; Lehto, J.; Lahdenperae, A.-M.

    2009-05-01

    The safety assessment of disposal of spent nuclear fuel will include an estimate on the behavior of nuclear waste nuclides in the biosphere. As a part of this estimate also the transfer of nuclear waste nuclides in the soil and sediments is to be considered. In this study soil samples were collected from three excavator pits in Olkiluoto and the geotechnical and chemical characteristics of the samples were determined. In later stage these results will be used in sorption tests. Aim of these tests is to determine the Kd-values for Cs, Tc and I and later for Mo, Nb and Cl. Results of these sorption tests will be reported later. The geotechnical characteristics studied included dry weight and organic matter content as well as grain size distribution and mineralogy analyses. Selective extractions were carried out to study the sorption of cations into different mineral types. The extractions included five steps in which the cations bound to exchangeable, carbonate, oxides of Fe and Mn, organic matter and residual fractions were determined. For all fractions ICPMS analyses were carried out. In these analyses Li, Na, Mg, K, Ca, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, Mo, Cd, Cs and Pb were determined. In addition six profiles were taken from the surroundings of two excavator pits for the 137 Cs determination. Besides the samples taken for the characterization of soil, supplement samples were taken from the same layers for the separation of soil water. From the soil water pH, DOC, anions (F, Cl, NO 3 , SO 4 ) and cations (Na, Mg, K, Ca, Al, Cr, Mn, Fe, Ni, Cu, Zn, As, S, Cd, Cs, Pb, U) were determined. (orig.)

  7. Defects study of hydrogenated amorphous silicon samples and their relation with the substrate and deposition conditions

    International Nuclear Information System (INIS)

    Darwich, R.

    2009-07-01

    The goal of this work is to study the properties of the defects aiming to explore the types of defects and the effect of various deposition parameters such as substrate temperature, the kind of the substrate, gas pressure and deposition rate. Two kinds of samples have been used; The first one was a series of Schottky diodes, and the second one a series of solar cells (p-i-n junction) deposited on crystalline silicon or on corning glass substrates with different deposition parameters. The deposition parameters were chosen to obtain materials whose their structures varying from amorphous to microcrystalline silicon including polymorphous silicon. Our results show that the polymorphous silicon samples deposited at high deposition rates present the best photovoltaic properties in comparison with those deposited at low rates. Also we found that the defects concentration in high deposition rate samples is less at least by two orders than that obtained in low deposition rate polymorphous, microcrystalline and amorphous samples. This study shows also that there is no effect of the substrate, or the thin films of highly doped amorphous silicon deposited on the substrate, on the creation and properties of these defects. Finally, different experimental methods have been used; a comparison between their results has been presented. (author)

  8. Special study for the manual transfer of process samples from CPP [Chemical Processing Plant] 601 to RAL [Remote Analytical Laboratory

    International Nuclear Information System (INIS)

    Marts, D.J.

    1987-05-01

    A study of alternate methods to manually transport radioactive samples from their glove boxes to the Remote Analytical Laboratory (RAL) was conducted at the Idaho National Engineering Laboratory. The study was performed to mitigate the effects of a potential loss of sampling capabilities that could take place if a malfunction in the Pneumatic Transfer System (PTS) occurred. Samples are required to be taken from the cell glove boxes and analyzed at the RAL regardless of the operational status of the PTS. This paper documents the conclusions of the study and how a decision was reached that determined the best handling scenarios for manually transporting 15 mL vials of liquid process samples from the K, W, U, WG, or WH cell glove boxes in the Chemical Processing Plant (CPP) 601 to the RAL. This study of methods to manually remove the samples from the glove boxes, package them for safe shipment, transport them by the safest route, receive them at the RAL, and safely unload them was conducted by EG and G Idaho, Inc., for Westinghouse Idaho Nuclear Company as part of the Glove Box Sampling and Transfer System Project for the Fuel Processing Facilities Upgrade, Task 10, Subtask 2. The study focused on the safest and most reliable scenarios that could be implemented using existing equipment. Hardware modifications and new hardware proposals were identified, and their impact on the handling scenario has been evaluated. A conclusion was reached that by utilizing the existing facility hardware, these samples can be safely transported manually from the sample stations in CPP 601 to the RAL, and that additional hardware could facilitate the transportation process even further

  9. Sorption and desorption studies of some radionuclides by soil samples. Vol. 4

    Energy Technology Data Exchange (ETDEWEB)

    El-Naggar, H A; Ezz El-Din, M R; Abd El-Gawad, A S [Hot Laborities Center, National Center for Nuclear Safety and Radiation control, Authority, Cairo (Egypt)

    1996-03-01

    The different factors influencing the sorption/desorption of {sup 137} Cs, {sup 60} Co, {sup 241} Am and {sup (152+154)}Eu by soil samples of Inshas area were investigated. Mineralogical analysis of the soil samples were carried out. The amount sorbed per gram soil (X/m) increased as the carrier concentration [C] increased from (10{sup -9} to 10{sup -}1 mol) following a freundlich type isotherm. The distribution coefficient [K d] of the radionuclides was found to be affected by pH. The presence of K{sup +}, Ca{sup 2+}, and Fe{sup 3+} as competing ions decreases the sorption capacity of the radioisotopes studied. The presence of complexing agents has a significant effect on the mobility of these radioisotopes. On the basis of the results obtained an attempt is being carried out to calculate different transport rates of the relevant isotopes in the investigated media. The mathematical model for the dispersion of the radioisotopes investigated in the groundwater environment was also elucidated. 4 figs., 2 tabs.

  10. Accurate recapture identification for genetic mark–recapture studies with error-tolerant likelihood-based match calling and sample clustering

    Science.gov (United States)

    Sethi, Suresh; Linden, Daniel; Wenburg, John; Lewis, Cara; Lemons, Patrick R.; Fuller, Angela K.; Hare, Matthew P.

    2016-01-01

    Error-tolerant likelihood-based match calling presents a promising technique to accurately identify recapture events in genetic mark–recapture studies by combining probabilities of latent genotypes and probabilities of observed genotypes, which may contain genotyping errors. Combined with clustering algorithms to group samples into sets of recaptures based upon pairwise match calls, these tools can be used to reconstruct accurate capture histories for mark–recapture modelling. Here, we assess the performance of a recently introduced error-tolerant likelihood-based match-calling model and sample clustering algorithm for genetic mark–recapture studies. We assessed both biallelic (i.e. single nucleotide polymorphisms; SNP) and multiallelic (i.e. microsatellite; MSAT) markers using a combination of simulation analyses and case study data on Pacific walrus (Odobenus rosmarus divergens) and fishers (Pekania pennanti). A novel two-stage clustering approach is demonstrated for genetic mark–recapture applications. First, repeat captures within a sampling occasion are identified. Subsequently, recaptures across sampling occasions are identified. The likelihood-based matching protocol performed well in simulation trials, demonstrating utility for use in a wide range of genetic mark–recapture studies. Moderately sized SNP (64+) and MSAT (10–15) panels produced accurate match calls for recaptures and accurate non-match calls for samples from closely related individuals in the face of low to moderate genotyping error. Furthermore, matching performance remained stable or increased as the number of genetic markers increased, genotyping error notwithstanding.

  11. A general method to determine sampling windows for nonlinear mixed effects models with an application to population pharmacokinetic studies.

    Science.gov (United States)

    Foo, Lee Kien; McGree, James; Duffull, Stephen

    2012-01-01

    Optimal design methods have been proposed to determine the best sampling times when sparse blood sampling is required in clinical pharmacokinetic studies. However, the optimal blood sampling time points may not be feasible in clinical practice. Sampling windows, a time interval for blood sample collection, have been proposed to provide flexibility in blood sampling times while preserving efficient parameter estimation. Because of the complexity of the population pharmacokinetic models, which are generally nonlinear mixed effects models, there is no analytical solution available to determine sampling windows. We propose a method for determination of sampling windows based on MCMC sampling techniques. The proposed method attains a stationary distribution rapidly and provides time-sensitive windows around the optimal design points. The proposed method is applicable to determine sampling windows for any nonlinear mixed effects model although our work focuses on an application to population pharmacokinetic models. Copyright © 2012 John Wiley & Sons, Ltd.

  12. Study of microtip-based extraction and purification of DNA from human samples for portable devices

    Science.gov (United States)

    Fotouhi, Gareth

    DNA sample preparation is essential for genetic analysis. However, rapid and easy-to-use methods are a major challenge to obtaining genetic information. Furthermore, DNA sample preparation technology must follow the growing need for point-of-care (POC) diagnostics. The current use of centrifuges, large robots, and laboratory-intensive protocols has to be minimized to meet the global challenge of limited access healthcare by bringing the lab to patients through POC devices. To address these challenges, a novel extraction method of genomic DNA from human samples is presented by using heat-cured polyethyleneimine-coated microtips generating a high electric field. The microtip extraction method is based on recent work using an electric field and capillary action integrated into an automated device. The main challenges to the method are: (1) to obtain a stable microtip surface for the controlled capture and release of DNA and (2) to improve the recovery of DNA from samples with a high concentration of inhibitors, such as human samples. The present study addresses these challenges by investigating the heat curing of polyethyleneimine (PEI) coated on the surface of the microtip. Heat-cured PEI-coated microtips are shown to control the capture and release of DNA. Protocols are developed for the extraction and purification of DNA from human samples. Heat-cured PEI-coated microtip methods of DNA sample preparation are used to extract genomic DNA from human samples. It is discovered through experiment that heat curing of a PEI layer on a gold-coated surface below 150°C could inhibit the signal of polymerase chain reaction (PCR). Below 150°C, the PEI layer is not completely cured and dissolved off the gold-coated surface. Dissolved PEI binds with DNA to inhibit PCR. Heat curing of a PEI layer above 150°C on a gold-coated surface prevents inhibition to PCR and gel electrophoresis. In comparison to gold-coated microtips, the 225°C-cured PEI-coated microtips improve the

  13. Alternaria and Fusarium in Norwegian grains of reduced quality - a matched pair sample study

    DEFF Research Database (Denmark)

    Kosiak, B.; Torp, M.; Skjerve, E.

    2004-01-01

    The occurrence and geographic distribution of species belonging to the genera Alternaria and Fusarium in grains of reduced and of acceptable quality were studied post-harvest in 1997 and 1998. A total of 260 grain samples of wheat, barley and oats was analysed. The distribution of Alternaria and ...

  14. Judgment on the presence of radionuclides in sample analysis: A case study

    International Nuclear Information System (INIS)

    Muhamat Omar; Zalina Laili; Mohd Suhaimi Hamzah

    2012-01-01

    Qualitative and quantitative analysis of samples require good judgment from the analysts. These two aspects in gamma spectrometric analysis of Proficiency Test and solid radioactive waste samples for the determination of radionuclides are discussed. It is vital to judge and decide what energy peaks belong to which radionuclides prior to the creation of customized radionuclide library for the analysis of specific samples. Corrections due to radionuclide decay and growth, and the half-life assigned to a particular radionuclide in the uranium and thorium series are also discussed. Discussion on judgment to confirm the presence of thorium in food samples based on gamma spectrometry and neutron activation analysis is also provided. (author)

  15. Environmental monitoring study of linear alkylbenzene sulfonates and insoluble soap in Spanish sewage sludge samples.

    Science.gov (United States)

    Cantarero, Samuel; Zafra-Gómez, Alberto; Ballesteros, Oscar; Navalón, Alberto; Reis, Marco S; Saraiva, Pedro M; Vílchez, José L

    2011-01-01

    In this work we present a monitoring study of linear alkylbenzene sulfonates (LAS) and insoluble soap performed on Spanish sewage sludge samples. This work focuses on finding statistical relations between LAS concentrations and insoluble soap in sewage sludge samples and variables related to wastewater treatment plants such as water hardness, population and treatment type. It is worth to mention that 38 samples, collected from different Spanish regions, were studied. The statistical tool we used was Principal Component Analysis (PC), in order to reduce the number of response variables. The analysis of variance (ANOVA) test and a non-parametric test such as the Kruskal-Wallis test were also studied through the estimation of the p-value (probability of obtaining a test statistic at least as extreme as the one that was actually observed, assuming that the null hypothesis is true) in order to study possible relations between the concentration of both analytes and the rest of variables. We also compared LAS and insoluble soap behaviors. In addition, the results obtained for LAS (mean value) were compared with the limit value proposed by the future Directive entitled "Working Document on Sludge". According to the results, the mean obtained for soap and LAS was 26.49 g kg(-1) and 6.15 g kg(-1) respectively. It is worth noting that LAS mean was significantly higher than the limit value (2.6 g kg(-1)). In addition, LAS and soap concentrations depend largely on water hardness. However, only LAS concentration depends on treatment type.

  16. [Comparative studies of personal and steady-state sampling for determining dust exposure in different job groups].

    Science.gov (United States)

    Cherneva, P; Lukanova, R

    1994-01-01

    The variability of the dust concentration in time and space, as well as the change of worker's place during the working process, define the necessity of introducing personal sampling in the hygiene control practice. However, the laboratory equipment with personal devices is still not sufficient. The aim of this work is to assess the dust exposure of the basic professional groups from the ore- and coal production in Bulgaria by personal sampling in comparative studies of the static ambient sampling used up to now. 63 full-shift investigations of the dust factor were performed on professional groups of miners of the polymetal and coal pits by static ambient devices-[Hygitest production] and personal [from firms "Casella", "Strolein" and "Gilian"] devices, after standardized methods. The results are data processed-by means of logarithmic normal distribution of the relation of the respirable dust concentrations, determined personally and by static ambient sampling. The limits of variation of this correlation are from 0.5 to 4.1 at average geometric value -0.95 and standard geometric deviation-1.8 i.e. both types of sampling are intersubstitutional for the examined groups and sites, as in the underground ores the professional risk of respirable dust is underestimated up to 4 times at static ambient sampling.

  17. A Study of Assimilation Bias in Name-Based Sampling of Migrants

    Directory of Open Access Journals (Sweden)

    Schnell Rainer

    2014-06-01

    Full Text Available The use of personal names for screening is an increasingly popular sampling technique for migrant populations. Although this is often an effective sampling procedure, very little is known about the properties of this method. Based on a large German survey, this article compares characteristics of respondents whose names have been correctly classified as belonging to a migrant population with respondentswho aremigrants and whose names have not been classified as belonging to a migrant population. Although significant differences were found for some variables even with some large effect sizes, the overall bias introduced by name-based sampling (NBS is small as long as procedures with small false-negative rates are employed.

  18. Prevalence of xenobiotic substances in first-trimester blood samples from Danish pregnant women: a cross-sectional study.

    Science.gov (United States)

    Aagaard, Sissel Kramer; Larsen, Agnete; Andreasen, Mette Findal; Lesnikova, Iana; Telving, Rasmus; Vestergaard, Anna Louise; Tørring, Niels; Uldbjerg, Niels; Bor, Pinar

    2018-03-03

    The aim of this study was to investigate the prevalence of xenobiotic substances, such as caffeine, nicotine and illicit drugs (eg, cannabis and cocaine), in blood samples from first-trimester Danish pregnant women unaware of the screening. A cross - sectional study examined 436 anonymised residual blood samples obtained during 2014 as part of the nationwide prenatal first-trimester screening programme. The samples were analysed by ultra performance liquid chromatography with high-resolution time-of-flight mass spectrometry. An antenatal clinic in a Danish city with 62 000 inhabitants, where >95% of pregnant women joined the screening programme. The prevalence and patterns of caffeine, nicotine, medication and illicit drug intake during the first trimester of pregnancy. The prevalence of prescription and over-the-counter drug detection was 17.9%, including acetaminophen (8.9%) and antidepressants (3.0%), of which citalopram (0.9%) was the most frequent. The prevalence of illegal drugs, indicators of smoking (nicotine/cotinine) and caffeine was 0.9%, 9.9%, and 76.4%, respectively. Only 17.4% of women had no substance identified in their sample. This study emphasises the need for further translational studies investigating lifestyle habits during pregnancy, as well as the underlying molecular mechanisms through which xenobiotic substances may affect placental function and fetal development. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Numeracy of multiple sclerosis patients: A comparison of patients from the PERCEPT study to a German probabilistic sample.

    Science.gov (United States)

    Gaissmaier, Wolfgang; Giese, Helge; Galesic, Mirta; Garcia-Retamero, Rocio; Kasper, Juergen; Kleiter, Ingo; Meuth, Sven G; Köpke, Sascha; Heesen, Christoph

    2018-01-01

    A shared decision-making approach is suggested for multiple sclerosis (MS) patients. To properly evaluate benefits and risks of different treatment options accordingly, MS patients require sufficient numeracy - the ability to understand quantitative information. It is unknown whether MS affects numeracy. Therefore, we investigated whether patients' numeracy was impaired compared to a probabilistic national sample. As part of the larger prospective, observational, multicenter study PERCEPT, we assessed numeracy for a clinical study sample of German MS patients (N=725) with a standard test and compared them to a German probabilistic sample (N=1001), controlling for age, sex, and education. Within patients, we assessed whether disease variables (disease duration, disability, annual relapse rate, cognitive impairment) predicted numeracy beyond these demographics. MS patients showed a comparable level of numeracy as the probabilistic national sample (68.9% vs. 68.5% correct answers, P=0.831). In both samples, numeracy was higher for men and the highly educated. Disease variables did not predict numeracy beyond demographics within patients, and predictability was generally low. This sample of MS patients understood quantitative information on the same level as the general population. There is no reason to withhold quantitative information from MS patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. On Invertible Sampling and Adaptive Security

    DEFF Research Database (Denmark)

    Ishai, Yuval; Kumarasubramanian, Abishek; Orlandi, Claudio

    2011-01-01

    functionalities was left open. We provide the first convincing evidence that the answer to this question is negative, namely that some (randomized) functionalities cannot be realized with adaptive security. We obtain this result by studying the following related invertible sampling problem: given an efficient...... sampling algorithm A, obtain another sampling algorithm B such that the output of B is computationally indistinguishable from the output of A, but B can be efficiently inverted (even if A cannot). This invertible sampling problem is independently motivated by other cryptographic applications. We show......, under strong but well studied assumptions, that there exist efficient sampling algorithms A for which invertible sampling as above is impossible. At the same time, we show that a general feasibility result for adaptively secure MPC implies that invertible sampling is possible for every A, thereby...

  1. Study of uranium mineralization in rock samples from marwat range bannu basin by fission track analysis technique

    International Nuclear Information System (INIS)

    Qureshi, A.Z.; Ullah, K.; Ullah, N.; Akram, M.

    2004-07-01

    The Geophysics Division, Atomic Energy Minerals Centre (AEMC), Lahore has planned a uranium exploration program in Marwat Range, Bannu Basin. In this connection 30 thin sections of rock samples, collected from four areas; namely, Darra Tang, Simukili, Karkanwal and Sheikhillah from Marwat Range, and one from Salt Range were provided to Nuclear Geology Group of Physics Research Division, PINSTECH for the study of nature and mechanism of uranium mineralization These studies are aimed to help in designing uranium exploration strategy by providing the loci of uranium sources in the Marwat and Salt Ranges. The samples have been studied using fission track analysis technique. (author)

  2. Identification and Correction of Sample Mix-Ups in Expression Genetic Data: A Case Study.

    Science.gov (United States)

    Broman, Karl W; Keller, Mark P; Broman, Aimee Teo; Kendziorski, Christina; Yandell, Brian S; Sen, Śaunak; Attie, Alan D

    2015-08-19

    In a mouse intercross with more than 500 animals and genome-wide gene expression data on six tissues, we identified a high proportion (18%) of sample mix-ups in the genotype data. Local expression quantitative trait loci (eQTL; genetic loci influencing gene expression) with extremely large effect were used to form a classifier to predict an individual's eQTL genotype based on expression data alone. By considering multiple eQTL and their related transcripts, we identified numerous individuals whose predicted eQTL genotypes (based on their expression data) did not match their observed genotypes, and then went on to identify other individuals whose genotypes did match the predicted eQTL genotypes. The concordance of predictions across six tissues indicated that the problem was due to mix-ups in the genotypes (although we further identified a small number of sample mix-ups in each of the six panels of gene expression microarrays). Consideration of the plate positions of the DNA samples indicated a number of off-by-one and off-by-two errors, likely the result of pipetting errors. Such sample mix-ups can be a problem in any genetic study, but eQTL data allow us to identify, and even correct, such problems. Our methods have been implemented in an R package, R/lineup. Copyright © 2015 Broman et al.

  3. HPV self-sampling in Japanese women: A feasibility study in a population with limited experience of tampon use.

    Science.gov (United States)

    Hanley, Sharon Jb; Fujita, Hiromasa; Yokoyama, Susumu; Kunisawa, Shiori; Tamakoshi, Akiko; Dong, Peixin; Kobayashi, Noriko; Watari, Hidemichi; Kudo, Masataka; Sakuragi, Noriaki

    2016-09-01

    Cervical cancer incidence and mortality is increasing in Japanese women under age 50. Screening uptake is low and proactive recommendations for human papillomavirus vaccination have been suspended. Other cervical cancer prevention initiatives are urgently needed. We assessed whether human papillomavirus self-sampling might be an acceptable alternative to physician-led screening, particularly in women with limited experience of tampon use. We also sought to identify any practical, logistical, or safety issues in women already attending for screening, before carrying out further large-scale studies in non-responders. In total, 203 women aged 20-49 attending their annual workplace healthcheck in Sapporo, northern Japan, performed unsupervised human papillomavirus self-sampling before undergoing a physician-led cervical smear and human papillomavirus test, and completing a measure of acceptability for both tests. Ninety per cent of participants stated they would use self-sampling again. They found instructions easy to follow and reported no issues with the usability of the self-sampling device. Compared with physician-led testing, women found self-sampling significantly less painful, less embarrassing and could relax more (p Women lacked confidence the test had been performed correctly, despite no unsatisfactory samples. No safety issues were reported. Self-sampling was highly acceptable in this population of women. They could perform the test safely unsupervised, but lacked confidence the test has been carried out correctly. Japanese women need to be educated about the accuracy of human papillomavirus self-sampling and further large-scale studies are necessary in non-responders. © The Author(s) 2016.

  4. Chemical Components of Noncommercial Alcohol Beverage Samples: A Study With the Viewpoint of Toxic Components in Mashhad, Iran.

    Science.gov (United States)

    Dadpour, Bita; Hedjazi, Arya; Ghorbani, Hamideh; Khosrojerdi, Hamid; Vaziri, Seyed Mohsen; Malek Zadeh, Haleh; Habibi Tamijani, Amir

    2016-06-01

    Iran has one of the lowest alcoholic beverage use rates in comparison with other countries, because it is legally forbidden and because of religious beliefs. Even so, unrecorded and noncommercial alcohol remains a considerable concern, which needs special attention. In the current research, we have studied the general composition of noncommercial alcohol samples to identify potentially toxic components in the context of the city of Mashhad in IR Iran. Using a descriptive study, chemical composition records of alcohol samples obtained from Mashhad and its suburbs (from March 2013 to March 2014) were evaluated in terms of ethanol percentage and methanol percentage using gas chromatography. Likewise, the pH of the alcohol and the location of the sample were also considered. Some substances, such as inorganic elements, were not included because there was no information about these substances in the records. Of 877 reports of alcohol samples, more than 50% were obtained from Mashhad and the rest were from the suburbs. Of the reports, 57.5% were in the spring and summer, followed by 42.5% in the fall and winter. The mean (min-max) of ethanol percentage was 30.04% (0 - 98.4). In four cases, methanol was detected. The mean (min-max) of methanol percentage was 23% (4 - 95).The majority of the samples had an acidic pH. The composition of unrecorded samples did not raise major toxicological concern beyond ethanol in alcohol products. However, concentration levels of methanol in some unrecorded alcohol samples made these samples detrimental for human consumption.

  5. Microbial Safety of Low Water Activity Foods: Study of Simulated and Durban Household Samples

    Directory of Open Access Journals (Sweden)

    O. A. Ijabadeniyi

    2017-01-01

    Full Text Available Sixty household low water activity foods were examined and a simulative study was conducted in a high sugar, low aw almond and macadamia butter to determine the survival of Bacillus cereus and Staphylococcus aureus ATCC 25923. Results obtained from 60 low aw samples collected at household level had some significant differences (P≤0,05 within food categories amongst the various tests. Spices had the highest number of aerobic bacteria, aerobic spore-formers, anaerobic spore-formers, and S. aureus. Mean aerobic colony counts for nuts and spices were 2.30 log CFU/g and 4.40 log CFU/g, respectively. Pathogens such as Escherichia coli and Cronobacter sakazakii were present in nuts, whilst Salmonella spp. was present in chocolates. This implies that certain low aw foods may present a public health risk. In the simulative study, temperature and high sucrose concentrations played a significant role in the survival of B. cereus and S. aureus ATCC 25923. B. cereus was found to be more osmotolerant at both reduced and elevated temperatures (18°C and 25°C in the 12% sucrose sample in both butters, whilst S. aureus ATCC 25923 seemed to grow better in sucrose-free samples at both temperatures in both butters. This implies that certain low aw foods may present a public health risk. Also, B. cereus, being a spore-forming bacterium, can be osmotolerant at both reduced and elevated temperatures.

  6. Study on sampling conditions for the monitoring of waste air

    International Nuclear Information System (INIS)

    Moeller, T.J.; Buetefisch, K.A.

    1998-01-01

    The technical codes for radiological monitoring of the waste air released from a radwaste repository demand that sampling for determination of aerosol-borne radioactivity is to be made with a screener equipped with a suitable number of measuring probes extending over the entire cross-sectional surface of the vent. Another requirement is to ensure that the waste air stream passing through the measuring channel is representative, containing the typical, operation-induced distribution of aerosols across the surface to be scanned. The study reported was intended to determine in a scaled-down model (1:10) of a repository ventilating duct the typical spatial distribution of aerosols (3D particulate density) in order to establish information on the type of typical distributions of aerosols, to be used for optimisation of the measuring site and monitoring instruments. (orig./CB) [de

  7. Study of five novel non-synonymous polymorphisms in human brain-expressed genes in a Colombian sample.

    Science.gov (United States)

    Ojeda, Diego A; Forero, Diego A

    2014-10-01

    Non-synonymous single nucleotide polymorphisms (nsSNPs) in brain-expressed genes represent interesting candidates for genetic research in neuropsychiatric disorders. To study novel nsSNPs in brain-expressed genes in a sample of Colombian subjects. We applied an approach based on in silico mining of available genomic data to identify and select novel nsSNPs in brain-expressed genes. We developed novel genotyping assays, based in allele-specific PCR methods, for these nsSNPs and genotyped them in 171 Colombian subjects. Five common nsSNPs (rs6855837; p.Leu395Ile, rs2305160; p.Thr394Ala, rs10503929; p.Met289Thr, rs2270641; p.Thr4Pro and rs3822659; p.Ser735Ala) were studied, located in the CLOCK, NPAS2, NRG1, SLC18A1 and WWC1 genes. We reported allele and genotype frequencies in a sample of South American healthy subjects. There is previous experimental evidence, arising from genome-wide expression and association studies, for the involvement of these genes in several neuropsychiatric disorders and endophenotypes, such as schizophrenia, mood disorders or memory performance. Frequencies for these nsSNPSs in the Colombian samples varied in comparison to different HapMap populations. Future study of these nsSNPs in brain-expressed genes, a synaptogenomics approach, will be important for a better understanding of neuropsychiatric diseases and endophenotypes in different populations.

  8. Correction of sampling bias in a cross-sectional study of post-surgical complications.

    Science.gov (United States)

    Fluss, Ronen; Mandel, Micha; Freedman, Laurence S; Weiss, Inbal Salz; Zohar, Anat Ekka; Haklai, Ziona; Gordon, Ethel-Sherry; Simchen, Elisheva

    2013-06-30

    Cross-sectional designs are often used to monitor the proportion of infections and other post-surgical complications acquired in hospitals. However, conventional methods for estimating incidence proportions when applied to cross-sectional data may provide estimators that are highly biased, as cross-sectional designs tend to include a high proportion of patients with prolonged hospitalization. One common solution is to use sampling weights in the analysis, which adjust for the sampling bias inherent in a cross-sectional design. The current paper describes in detail a method to build weights for a national survey of post-surgical complications conducted in Israel. We use the weights to estimate the probability of surgical site infections following colon resection, and validate the results of the weighted analysis by comparing them with those obtained from a parallel study with a historically prospective design. Copyright © 2012 John Wiley & Sons, Ltd.

  9. Directional dependency of air sampling

    International Nuclear Information System (INIS)

    1994-01-01

    A field study was performed by Idaho State University-Environmental Monitoring Laboratory (EML) to examine the directional dependency of low-volume air samplers. A typical continuous low volume air sampler contains a sample head that is mounted on the sampler housing either horizontally through one of four walls or vertically on an exterior wall 'looking down or up.' In 1992, a field study was undertaken to estimate sampling error and to detect the directional effect of sampler head orientation. Approximately 1/2 mile downwind from a phosphate plant (continuous source of alpha activity), four samplers were positioned in identical orientation alongside one sampler configured with the sample head 'looking down'. At least five consecutive weekly samples were collected. The alpha activity, beta activity, and the Be-7 activity collected on the particulate filter were analyzed to determine sampling error. Four sample heads were than oriented to the four different horizontal directions. Samples were collected for at least five weeks. Analysis of the alpha data can show the effect of sampler orientation to a know near source term. Analysis of the beta and Be-7 activity shows the effect of sampler orientation to a ubiquitous source term

  10. AMS measurement of samples smaller than 300 {mu}g at center for applied isotope studies, University of Georgia

    Energy Technology Data Exchange (ETDEWEB)

    Cherkinsky, Alexander, E-mail: acherkin@uga.edu [CENTER FOR APPLIED ISOTOPE STUDIES, University of Georgia, 120 Riverbend Road, Athens, GA 30602 (United States); Ravi Prasad, G.V.; Dvoracek, Doug [CENTER FOR APPLIED ISOTOPE STUDIES, University of Georgia, 120 Riverbend Road, Athens, GA 30602 (United States)

    2013-01-15

    The center for applied isotope studies has developed a protocol for the measurement of radiocarbon in the range 0.01-0.3 mg of carbon. We analyzed a series of radiocarbon-free and modern standards using the same sample preparation procedure as for unknown samples. We have studied the size dependency of {sup 12}C and {sup 13}C beam currents and {sup 14}C/{sup 13}C ratios from cathodes containing less than 1 mg of carbon. The iron catalyst used for graphite preparation contains some carbon with activity about 60 pMC and the level of contamination varies between batches from the same supplier. The cathodes in the range smaller than 50 {mu}g showed a very significant dependency between current and the sample size. In this range the current increased by about fifteen-fold; between 50 and 100 {mu}g the current increased two-fold. Samples larger than 300 {mu}g have shown negligible current variation. The {sup 14}C/{sup 13}C ratio was significantly affected only for the samples less than 50 {mu}g. Larger samples have shown very little variation in the {sup 14}C/{sup 13}C ratio. For the measurement of ultra-small unknown samples in the range of 10-50 {mu}g, we have found it to be important to use blanks and modern standards with exactly the same amount of carbon, which makes it possible to apply a mass-balanced correction.

  11. Detection of multidrug-resistant tuberculosis from stored DNA Samples: A multicenter study

    Directory of Open Access Journals (Sweden)

    Marie Sylvianne Rabodoarivelo

    2018-01-01

    Full Text Available Background: In low-income countries, rapid detection of tuberculosis (TB drug resistance is often restricted by the difficulties of transporting and storing sputum samples from remote health centers to the reference laboratories where molecular tests are available. The aim of this study was to evaluate the performance of four transport and storage systems for molecular detection of rifampicin (RIF and isoniazid (INH resistance. Methods: This was a multicenter study. Molecular detection of RIF and INH resistance was performed directly from smear-positive TB sputa spotted on a slide, FTA card, GenoCard, and ethanol using the Genotype MTBDRplus assay. The performance of the DNA extraction method from each storage support to detect drug resistance was assessed by calculating their sensitivity and specificity compared to the phenotypic method. Results: From all sites, the overall sensitivity and specificity for RIF-resistance detection was 88% and 85%, respectively, for slides, 86% and 92%, respectively, for GenoCard, 87% and 89%, respectively, for FTA card, and 88% and 92%, respectively, for ethanol. For INH-resistance detection, the overall sensitivity and specificity was 82% and 90%, respectively, for slides, 85% and 96%, respectively, for GenoCard, 86% and 92%, respectively, for FTA card, and 86% and 94%, respectively, for ethanol. Conclusion: Smear slides and filter cards showed to be very useful tools to facilitate DNA extraction from sputum samples with the potential to accelerate the detection of drug resistance in remote areas.

  12. Detection of multidrug-resistant tuberculosis from stored DNA Samples: A multicenter study.

    Science.gov (United States)

    Rabodoarivelo, Marie Sylvianne; Brandao, A; Cergole Novella, M C; C Bombonatte, A G; Imperiale, B; Rakotosamimanana, N; Morcillo, N; Rasolofo, V; Palomino, J C; Martin, A

    2018-01-01

    In low-income countries, rapid detection of tuberculosis (TB) drug resistance is often restricted by the difficulties of transporting and storing sputum samples from remote health centers to the reference laboratories where molecular tests are available. The aim of this study was to evaluate the performance of four transport and storage systems for molecular detection of rifampicin (RIF) and isoniazid (INH) resistance. This was a multicenter study. Molecular detection of RIF and INH resistance was performed directly from smear-positive TB sputa spotted on a slide, FTA card, GenoCard, and ethanol using the Genotype MTBDRplus assay. The performance of the DNA extraction method from each storage support to detect drug resistance was assessed by calculating their sensitivity and specificity compared to the phenotypic method. From all sites, the overall sensitivity and specificity for RIF-resistance detection was 88% and 85%, respectively, for slides, 86% and 92%, respectively, for GenoCard, 87% and 89%, respectively, for FTA card, and 88% and 92%, respectively, for ethanol. For INH-resistance detection, the overall sensitivity and specificity was 82% and 90%, respectively, for slides, 85% and 96%, respectively, for GenoCard, 86% and 92%, respectively, for FTA card, and 86% and 94%, respectively, for ethanol. Smear slides and filter cards showed to be very useful tools to facilitate DNA extraction from sputum samples with the potential to accelerate the detection of drug resistance in remote areas.

  13. Use of robotic systems for radiochemical sample changing and for analytical sample preparation

    International Nuclear Information System (INIS)

    Delmastro, J.R.; Hartenstein, S.D.; Wade, M.A.

    1989-01-01

    Two uses of the Perkin-Elmer (PE) robotic system will be presented. In the first, a PE robot functions as an automatic sample changer for up to five low energy photon spectrometry (LEPS) detectors operated with a Nuclear Data ND 6700 system. The entire system, including the robot, is controlled by an IBM PC-AT using software written in compiled BASIC. Problems associated with the development of the system and modifications to the robot will be presented. In the second, an evaluation study was performed to assess the abilities of the PE robotic system for performing complex analytical sample preparation procedures. For this study, a robotic system based upon the PE robot and auxiliary devices was constructed and programmed to perform the preparation of final product samples (UO 3 ) for accountability and impurity specification analyses. These procedures require sample dissolution, dilution, and liquid-liquid extraction steps. The results of an in-depth evaluation of all system components will be presented

  14. Study of Cs/sup 137/ contamination in soil and food samples of Jhangar valley, Pakistan

    International Nuclear Information System (INIS)

    Chaudhry, Z.S.; Khan, H.M.; Aslam, M.; Iqbal, S.; Orfi, S.D.

    2001-01-01

    Chernobyl accident has been the main source of artificial radioactive contamination throughout the world and its effects have been found in Pakistan as well. In the present study, activities of an important anthropogenic radionuclide, Cs/sup 137/ in soil and food samples of Jhangar Valley of Pakistan have been determined using PC based gamma spectrometer. Soil-375 from IAEA was used as reference material. The soil samples were collected from the agricultural fields of the selected area while food samples, grown in the selected area, were collected from the fields or from local market. After proper treatment, the samples were analyzed using a high purity germanium (HPGe) detector. The following values for average specific activity of Cs/sup 137/ were found: soil (range 1.3-46.8 Bq/kg) (12.0 Bq/kg), wheat (0.9 +- 0.05 Bq/kg), millet (1.5 +- 0.06 Bq/kg), lentils (2.0 +- 0.1 Bq/kg), potato (0.6 +- 0.03 Bq/kg) and cauliflower (0.6 +- 0.03 Bq/kg). The results have been discussed and compared with other data available in the literature. (author)

  15. Use of FTA cards for direct sampling of patients' lesions in the ecological study of cutaneous leishmaniasis.

    Science.gov (United States)

    Kato, Hirotomo; Cáceres, Abraham G; Mimori, Tatsuyuki; Ishimaru, Yuka; Sayed, Amal S M; Fujita, Megumi; Iwata, Hiroyuki; Uezato, Hiroshi; Velez, Lenin N; Gomez, Eduardo A L; Hashiguchi, Yoshihisa

    2010-10-01

    The FTA card (Whatman) was assessed for its utility as a molecular epidemiological tool in collecting samples from patients with leishmaniasis in Peru because the card has a variety of merits; it is less invasive for patients and easy to handle for both physicians and other medical personnel for sample collection or diagnosis, in addition to its simplicity and easy countrywide and/or intercountry transportation for analysis. Samples were collected from 132 patients suspected of having leishmaniasis, and Leishmania species were successfully identified in samples from 81 patients in 15 departments of Peru by cytochrome b and mannose phosphate isomerase gene analyses. Of these, 61.7% were identified as Leishmania (Viannia) peruviana, 22.2% as L. (V.) braziliensis, 12.3% as L. (V.) guyanensis, 2.5% as L. (V.) shawi, and 1.2% as L. (V.) lainsoni. The three predominant species, L. (V.) peruviana, L. (V.) braziliensis, and L. (V.) guyanensis, were mainly found in the Andean highlands, in the tropical rainforest, and in northern and central rainforest regions, respectively. This is the first time L. (V.) shawi has been identified outside Brazil. The present study showed that the FTA card will be a useful tool for the ecological study of different forms of leishmaniasis. Furthermore, collecting samples directly from patients' lesions by using the FTA card eliminates (i) the possibility of contamination of Leishmania isolates during short- and/or long-term passages of culture in vitro in each laboratory and (ii) pain and suffering of patients from taking samples by skin biopsy.

  16. Teknik Sampling Snowball dalam Penelitian Lapangan

    Directory of Open Access Journals (Sweden)

    Nina Nurdiani

    2014-12-01

    Full Text Available Field research can be associated with both qualitative and quantitative research methods, depending on the problems faced and the goals to be achieved. The success of data collection in the field research depends on the determination of the appropriate sampling technique, to obtain accurate data, and reliably. In studies that have problems related to specific issues, requiring a non-probability sampling techniques one of which is the snowball sampling technique. This technique is useful for finding, identifying, selecting and taking samples in a network or chain of relationships. Phased implementation procedures performed through interviews and questionnaires. Snowball sampling technique has strengths and weaknesses in its application. Field research housing sector become the case study to explain this sampling technique.

  17. Information sampling behavior with explicit sampling costs

    Science.gov (United States)

    Juni, Mordechai Z.; Gureckis, Todd M.; Maloney, Laurence T.

    2015-01-01

    The decision to gather information should take into account both the value of information and its accrual costs in time, energy and money. Here we explore how people balance the monetary costs and benefits of gathering additional information in a perceptual-motor estimation task. Participants were rewarded for touching a hidden circular target on a touch-screen display. The target’s center coincided with the mean of a circular Gaussian distribution from which participants could sample repeatedly. Each “cue” — sampled one at a time — was plotted as a dot on the display. Participants had to repeatedly decide, after sampling each cue, whether to stop sampling and attempt to touch the hidden target or continue sampling. Each additional cue increased the participants’ probability of successfully touching the hidden target but reduced their potential reward. Two experimental conditions differed in the initial reward associated with touching the hidden target and the fixed cost per cue. For each condition we computed the optimal number of cues that participants should sample, before taking action, to maximize expected gain. Contrary to recent claims that people gather less information than they objectively should before taking action, we found that participants over-sampled in one experimental condition, and did not significantly under- or over-sample in the other. Additionally, while the ideal observer model ignores the current sample dispersion, we found that participants used it to decide whether to stop sampling and take action or continue sampling, a possible consequence of imperfect learning of the underlying population dispersion across trials. PMID:27429991

  18. Sampling Studies at an Air Force Live-Fire Bombing Range Impact Area

    National Research Council Canada - National Science Library

    Jenkins, Thomas F; Hewitt, Alan D; Ramsey, Charles A; Bjella, Kevin L; Bigl, Susan R; Lambert, Dennis J

    2006-01-01

    .... The main objective was to assess the effectiveness of using a systematic-random, multi-increment sampling strategy for the collection of representative surface soil samples in areas where bombing...

  19. Evaluation of limited sampling models for prediction of oral midazolam AUC for CYP3A phenotyping and drug interaction studies.

    Science.gov (United States)

    Mueller, Silke C; Drewelow, Bernd

    2013-05-01

    The area under the concentration-time curve (AUC) after oral midazolam administration is commonly used for cytochrome P450 (CYP) 3A phenotyping studies. The aim of this investigation was to evaluate a limited sampling strategy for the prediction of AUC with oral midazolam. A total of 288 concentration-time profiles from 123 healthy volunteers who participated in four previously performed drug interaction studies with intense sampling after a single oral dose of 7.5 mg midazolam were available for evaluation. Of these, 45 profiles served for model building, which was performed by stepwise multiple linear regression, and the remaining 243 datasets served for validation. Mean prediction error (MPE), mean absolute error (MAE) and root mean squared error (RMSE) were calculated to determine bias and precision The one- to four-sampling point models with the best coefficient of correlation were the one-sampling point model (8 h; r (2) = 0.84), the two-sampling point model (0.5 and 8 h; r (2) = 0.93), the three-sampling point model (0.5, 2, and 8 h; r (2) = 0.96), and the four-sampling point model (0.5,1, 2, and 8 h; r (2) = 0.97). However, the one- and two-sampling point models were unable to predict the midazolam AUC due to unacceptable bias and precision. Only the four-sampling point model predicted the very low and very high midazolam AUC of the validation dataset with acceptable precision and bias. The four-sampling point model was also able to predict the geometric mean ratio of the treatment phase over the baseline (with 90 % confidence interval) results of three drug interaction studies in the categories of strong, moderate, and mild induction, as well as no interaction. A four-sampling point limited sampling strategy to predict the oral midazolam AUC for CYP3A phenotyping is proposed. The one-, two- and three-sampling point models were not able to predict midazolam AUC accurately.

  20. Gamma-ray yield dependence on bulk density and moisture content of a sample of a PGNAA setup. A Monte Carlo study

    International Nuclear Information System (INIS)

    Nagadi, M.M.; Naqvi, A.A.

    2007-01-01

    Monte Carlo calculations were carried out to study the dependence of γ-ray yield on the bulk density and moisture content of a sample in a thermalneutron capture-based prompt gamma neutron activation analysis (PGNAA) setup. The results of the study showed a strong dependence of the γ-ray yield upon the sample bulk density. An order of magnitude increase in yield of 1.94 and 6.42 MeV prompt γ-rays from calcium in a Portland cement sample was observed for a corresponding order of magnitude increase in the sample bulk density. On the contrary the γ-ray yield has a weak dependence on sample moisture content and an increase of only 20% in yield of 1.94 and 6.42 MeV prompt γ-rays from calcium in the Portland cement sample was observed for an order of magnitude increase in the moisture content of the Portland cement sample. A similar effect of moisture content has been observed on the yield of 1.167 MeV prompt γ-rays from chlorine contaminants in Portland cement samples. For an order of magnitude increase in the moisture content of the sample, a 7 to 12% increase in the yield of the 1.167 MeV chlorine γ-ray was observed for the Portland cement samples containing 1 to 5 wt.% chlorine contaminants. This study has shown that effects of sample moisture content on prompt γ-ray yield from constituents of a Portland cement sample are insignificant in a thermal-neutrons capture-based PGNAA setup. (author)

  1. DWPF Sample Vial Insert Study-Statistical Analysis of DWPF Mock-Up Test Data

    Energy Technology Data Exchange (ETDEWEB)

    Harris, S.P. [Westinghouse Savannah River Company, AIKEN, SC (United States)

    1997-09-18

    This report is prepared as part of Technical/QA Task Plan WSRC-RP-97-351 which was issued in response to Technical Task Request HLW/DWPF/TTR-970132 submitted by DWPF. Presented in this report is a statistical analysis of DWPF Mock-up test data for evaluation of two new analytical methods which use insert samples from the existing HydragardTM sampler. The first is a new hydrofluoric acid based method called the Cold Chemical Method (Cold Chem) and the second is a modified fusion method.Either new DWPF analytical method could result in a two to three fold improvement in sample analysis time.Both new methods use the existing HydragardTM sampler to collect a smaller insert sample from the process sampling system. The insert testing methodology applies to the DWPF Slurry Mix Evaporator (SME) and the Melter Feed Tank (MFT) samples.The insert sample is named after the initial trials which placed the container inside the sample (peanut) vials. Samples in small 3 ml containers (Inserts) are analyzed by either the cold chemical method or a modified fusion method. The current analytical method uses a HydragardTM sample station to obtain nearly full 15 ml peanut vials. The samples are prepared by a multi-step process for Inductively Coupled Plasma (ICP) analysis by drying, vitrification, grinding and finally dissolution by either mixed acid or fusion. In contrast, the insert sample is placed directly in the dissolution vessel, thus eliminating the drying, vitrification and grinding operations for the Cold chem method. Although the modified fusion still requires drying and calcine conversion, the process is rapid due to the decreased sample size and that no vitrification step is required.A slurry feed simulant material was acquired from the TNX pilot facility from the test run designated as PX-7.The Mock-up test data were gathered on the basis of a statistical design presented in SRT-SCS-97004 (Rev. 0). Simulant PX-7 samples were taken in the DWPF Analytical Cell Mock

  2. Samples and Sampling Protocols for Scientific Investigations | Joel ...

    African Journals Online (AJOL)

    ... from sampling, through sample preparation, calibration to final measurement and reporting. This paper, therefore offers useful information on practical guidance on sampling protocols in line with best practice and international standards. Keywords: Sampling, sampling protocols, chain of custody, analysis, documentation ...

  3. Inorganic elements in sugar samples

    International Nuclear Information System (INIS)

    Salles, Paulo M.B. de; Campos, Tarcisio P.R. de

    2013-01-01

    Sugar is considered a safe food ingredient; however, it can be contaminated by organic elements since its planting until its production process. Thus, this study aims at checking the presence of inorganic elements in samples of crystal, refined and brown sugar available for consumption in Brazil. The applied technique was neutron activation analysis, the k 0 method, using the TRIGA MARK - IPR-R1 reactor located at CDTN/CNEN, in Belo Horizonte. It was identified the presence of elements such as, Au, Br, Co, Cr, Hf, K, Na, Sb, Sc and Zn in the samples of crystal/refined sugar and the presence of As, Au, Br, Ca, Co, Cr, Cs, Fe, Hf, K, Na, Sb, Sc, Sm, Sr, Th and Zn in the brown sugar samples. The applied technique was appropriate to this study because it was not necessary to put the samples in solution, essential condition in order to apply other techniques, avoiding contaminations and sample losses, besides allowing a multi elementary detection in different sugar samples. (author)

  4. Inorganic elements in sugar samples

    Energy Technology Data Exchange (ETDEWEB)

    Salles, Paulo M.B. de; Campos, Tarcisio P.R. de, E-mail: pauladesalles@yahoo.com.br, E-mail: tprcampos@pq.cnpq.br [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Menezes, Maria Angela de B.C., E-mail: menezes@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    Sugar is considered a safe food ingredient; however, it can be contaminated by organic elements since its planting until its production process. Thus, this study aims at checking the presence of inorganic elements in samples of crystal, refined and brown sugar available for consumption in Brazil. The applied technique was neutron activation analysis, the k{sub 0} method, using the TRIGA MARK - IPR-R1 reactor located at CDTN/CNEN, in Belo Horizonte. It was identified the presence of elements such as, Au, Br, Co, Cr, Hf, K, Na, Sb, Sc and Zn in the samples of crystal/refined sugar and the presence of As, Au, Br, Ca, Co, Cr, Cs, Fe, Hf, K, Na, Sb, Sc, Sm, Sr, Th and Zn in the brown sugar samples. The applied technique was appropriate to this study because it was not necessary to put the samples in solution, essential condition in order to apply other techniques, avoiding contaminations and sample losses, besides allowing a multi elementary detection in different sugar samples. (author)

  5. Study of radioelements drained by Rhone stream to Mediterranean Sea: Strategy of sampling and methodology

    International Nuclear Information System (INIS)

    Arnaud, M.; Charmasson, S.; Calmet, D.; Fernandez, J.M.

    1992-01-01

    This paper describes the methods used for water and sediments sampling in rivers and sea. The purpose is the study of radionuclide migration (Cesium 134, Cesium 137) in Mediterranean Sea (Gulf of Lion). 20 refs., 11 figs., 1 tab

  6. Low temperature X-ray diffraction studies of natural gas hydrate samples from the Gulf of Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Rawn, C.J. [Oak Ridge National Laboratory, Oak Ridge, TN (United States). Materials Science and Technology Div.; Sassen, R. [Texas A and M Univ., College Station, TX (United States). Geochemical and Environmental Research Group; Ulrich, S.M.; Phelps, T.J. [Oak Ridge National Laboratory, Oak Ridge, TN (United States). Biosciences Div.; Chakoumakos, B.C. [Oak Ridge National Laboratory, Oak Ridge, TN (United States). Neutron Scattering Science Div.; Payzant, E.A. [Oak Ridge National Laboratory, Oak Ridge, TN (United States). Center for Nanophase Materials Science

    2008-07-01

    Quantitative studies of natural clathrate hydrates are hampered by the difficulties associated with obtaining pristine samples for the sea floor without comprising their integrity. This paper discussed X-ray power diffraction studies conducted to measure natural gas hydrate samples obtained from the Green Canyon in the Gulf of Mexico. Data on the hydrate deposits were initially collected in 2002. The X-ray diffraction data were collected in order to examine the structure 2 (s2) gas hydrates as functions of temperature and time. A diffractometer with a theta-theta goniometer modified with a helium closed cycle refrigerator and temperature controller was used. Aragonite, quartz and halite phases were determined in the decomposed sample. Refined phase fractions for both the ice and the s2 hydrate were obtained as a function of temperature. Results of the study demonstrated that the amount of hydrates decreased with increasing temperatures and amounts of time. Large pieces of the hydrate showed heterogenous ice content. Dissociation rates were higher at lower temperatures. It was concluded that unusual trends observed for the smaller lattice parameter of the hydrates resulted from the formation of ice layers that acted as barriers to the released gases and caused increased isostatic pressures around the hydrate core. 9 refs., 6 figs.

  7. Sampling atmospheric pesticides with SPME: Laboratory developments and field study

    International Nuclear Information System (INIS)

    Wang Junxia; Tuduri, Ludovic; Mercury, Maud; Millet, Maurice; Briand, Olivier; Montury, Michel

    2009-01-01

    To estimate the atmospheric exposure of the greenhouse workers to pesticides, solid phase microextraction (SPME) was used under non-equilibrium conditions. Using Fick's law of diffusion, the concentrations of pesticides in the greenhouse can be calculated using pre-determined sampling rates (SRs). Thus the sampling rates (SRs) of two modes of SPME in the lab and in the field were determined and compared. The SRs for six pesticides in the lab were 20.4-48.3 mL min -1 for the exposed fiber and 0.166-0.929 mL min -1 for the retracted fiber. In field sampling, two pesticides, dichlorvos and cyprodinil were detected with exposed SPME. SR with exposed SPME for dichlorvos in the field (32.4 mL min -1 ) was consistent with that in the lab (34.5 mL min -1 ). SR for dichlorvos in the field (32.4 mL min -1 ) was consistent with that in the lab (34.5 mL min -1 ). The trends of temporal concentration and the inhalation exposure were also obtained. - SPME was proved to be a powerful and simple tool for determining pesticides' atmospheric concentration

  8. 40 CFR 761.323 - Sample preparation.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sample preparation. 761.323 Section... Remediation Waste Samples § 761.323 Sample preparation. (a) The comparison study requires analysis of a... concentrations by dilution. Any excess material resulting from the preparation of these samples, which is not...

  9. Sample design effects in landscape genetics

    Science.gov (United States)

    Oyler-McCance, Sara J.; Fedy, Bradley C.; Landguth, Erin L.

    2012-01-01

    An important research gap in landscape genetics is the impact of different field sampling designs on the ability to detect the effects of landscape pattern on gene flow. We evaluated how five different sampling regimes (random, linear, systematic, cluster, and single study site) affected the probability of correctly identifying the generating landscape process of population structure. Sampling regimes were chosen to represent a suite of designs common in field studies. We used genetic data generated from a spatially-explicit, individual-based program and simulated gene flow in a continuous population across a landscape with gradual spatial changes in resistance to movement. Additionally, we evaluated the sampling regimes using realistic and obtainable number of loci (10 and 20), number of alleles per locus (5 and 10), number of individuals sampled (10-300), and generational time after the landscape was introduced (20 and 400). For a simulated continuously distributed species, we found that random, linear, and systematic sampling regimes performed well with high sample sizes (>200), levels of polymorphism (10 alleles per locus), and number of molecular markers (20). The cluster and single study site sampling regimes were not able to correctly identify the generating process under any conditions and thus, are not advisable strategies for scenarios similar to our simulations. Our research emphasizes the importance of sampling data at ecologically appropriate spatial and temporal scales and suggests careful consideration for sampling near landscape components that are likely to most influence the genetic structure of the species. In addition, simulating sampling designs a priori could help guide filed data collection efforts.

  10. The CUPID (Cultural and Psychosocial Influences on Disability study: methods of data collection and characteristics of study sample.

    Directory of Open Access Journals (Sweden)

    David Coggon

    Full Text Available The CUPID (Cultural and Psychosocial Influences on Disability study was established to explore the hypothesis that common musculoskeletal disorders (MSDs and associated disability are importantly influenced by culturally determined health beliefs and expectations. This paper describes the methods of data collection and various characteristics of the study sample.A standardised questionnaire covering musculoskeletal symptoms, disability and potential risk factors, was used to collect information from 47 samples of nurses, office workers, and other (mostly manual workers in 18 countries from six continents. In addition, local investigators provided data on economic aspects of employment for each occupational group. Participation exceeded 80% in 33 of the 47 occupational groups, and after pre-specified exclusions, analysis was based on 12,426 subjects (92 to 1018 per occupational group. As expected, there was high usage of computer keyboards by office workers, while nurses had the highest prevalence of heavy manual lifting in all but one country. There was substantial heterogeneity between occupational groups in economic and psychosocial aspects of work; three- to five-fold variation in awareness of someone outside work with musculoskeletal pain; and more than ten-fold variation in the prevalence of adverse health beliefs about back and arm pain, and in awareness of terms such as "repetitive strain injury" (RSI.The large differences in psychosocial risk factors (including knowledge and beliefs about MSDs between occupational groups should allow the study hypothesis to be addressed effectively.

  11. The CUPID (Cultural and Psychosocial Influences on Disability) Study: Methods of Data Collection and Characteristics of Study Sample

    Science.gov (United States)

    Coggon, David; Ntani, Georgia; Palmer, Keith T.; Felli, Vanda E.; Harari, Raul; Barrero, Lope H.; Felknor, Sarah A.; Gimeno, David; Cattrell, Anna; Serra, Consol; Bonzini, Matteo; Solidaki, Eleni; Merisalu, Eda; Habib, Rima R.; Sadeghian, Farideh; Kadir, Masood; Warnakulasuriya, Sudath S. P.; Matsudaira, Ko; Nyantumbu, Busisiwe; Sim, Malcolm R.; Harcombe, Helen; Cox, Ken; Marziale, Maria H.; Sarquis, Leila M.; Harari, Florencia; Freire, Rocio; Harari, Natalia; Monroy, Magda V.; Quintana, Leonardo A.; Rojas, Marianela; Salazar Vega, Eduardo J.; Harris, E. Clare; Vargas-Prada, Sergio; Martinez, J. Miguel; Delclos, George; Benavides, Fernando G.; Carugno, Michele; Ferrario, Marco M.; Pesatori, Angela C.; Chatzi, Leda; Bitsios, Panos; Kogevinas, Manolis; Oha, Kristel; Sirk, Tuuli; Sadeghian, Ali; Peiris-John, Roshini J.; Sathiakumar, Nalini; Wickremasinghe, A. Rajitha; Yoshimura, Noriko; Kielkowski, Danuta; Kelsall, Helen L.; Hoe, Victor C. W.; Urquhart, Donna M.; Derett, Sarah; McBride, David; Gray, Andrew

    2012-01-01

    Background The CUPID (Cultural and Psychosocial Influences on Disability) study was established to explore the hypothesis that common musculoskeletal disorders (MSDs) and associated disability are importantly influenced by culturally determined health beliefs and expectations. This paper describes the methods of data collection and various characteristics of the study sample. Methods/Principal Findings A standardised questionnaire covering musculoskeletal symptoms, disability and potential risk factors, was used to collect information from 47 samples of nurses, office workers, and other (mostly manual) workers in 18 countries from six continents. In addition, local investigators provided data on economic aspects of employment for each occupational group. Participation exceeded 80% in 33 of the 47 occupational groups, and after pre-specified exclusions, analysis was based on 12,426 subjects (92 to 1018 per occupational group). As expected, there was high usage of computer keyboards by office workers, while nurses had the highest prevalence of heavy manual lifting in all but one country. There was substantial heterogeneity between occupational groups in economic and psychosocial aspects of work; three- to five-fold variation in awareness of someone outside work with musculoskeletal pain; and more than ten-fold variation in the prevalence of adverse health beliefs about back and arm pain, and in awareness of terms such as “repetitive strain injury” (RSI). Conclusions/Significance The large differences in psychosocial risk factors (including knowledge and beliefs about MSDs) between occupational groups should allow the study hypothesis to be addressed effectively. PMID:22792189

  12. Sampling free energy surfaces as slices by combining umbrella sampling and metadynamics.

    Science.gov (United States)

    Awasthi, Shalini; Kapil, Venkat; Nair, Nisanth N

    2016-06-15

    Metadynamics (MTD) is a very powerful technique to sample high-dimensional free energy landscapes, and due to its self-guiding property, the method has been successful in studying complex reactions and conformational changes. MTD sampling is based on filling the free energy basins by biasing potentials and thus for cases with flat, broad, and unbound free energy wells, the computational time to sample them becomes very large. To alleviate this problem, we combine the standard Umbrella Sampling (US) technique with MTD to sample orthogonal collective variables (CVs) in a simultaneous way. Within this scheme, we construct the equilibrium distribution of CVs from biased distributions obtained from independent MTD simulations with umbrella potentials. Reweighting is carried out by a procedure that combines US reweighting and Tiwary-Parrinello MTD reweighting within the Weighted Histogram Analysis Method (WHAM). The approach is ideal for a controlled sampling of a CV in a MTD simulation, making it computationally efficient in sampling flat, broad, and unbound free energy surfaces. This technique also allows for a distributed sampling of a high-dimensional free energy surface, further increasing the computational efficiency in sampling. We demonstrate the application of this technique in sampling high-dimensional surface for various chemical reactions using ab initio and QM/MM hybrid molecular dynamics simulations. Further, to carry out MTD bias reweighting for computing forward reaction barriers in ab initio or QM/MM simulations, we propose a computationally affordable approach that does not require recrossing trajectories. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  13. Study of sampling rate influence on neutron-gamma discrimination with stilbene coupled to a silicon photomultiplier.

    Science.gov (United States)

    Zhang, Jinglong; Moore, Michael E; Wang, Zhonghai; Rong, Zhou; Yang, Chaowen; Hayward, Jason P

    2017-10-01

    Choosing a digitizer with an appropriate sampling rate is often a trade-off between performance and economy. The influence of sampling rates on the neutron-gamma Pulse Shape Discrimination (PSD) with a solid stilbene scintillator coupled to a Silicon Photomultiplier was investigated in this work. Sampling rates from 125MSPS to 2GSPS from a 10-bit digitizer were used to collect detector pulses produced by the interactions of a Cf-252 source. Due to the decreased signal-to-noise ratio (SNR), the PSD performance degraded with reduced sampling rates. The reason of PSD performance degradation was discussed. Then, an efficient combination of filtering and digital signal processing (DSP) was then applied to suppress the timing noise and electronic background noise. The results demonstrate an improved PSD performance especially at low sampling rates, down to 125MSPS. Using filtering and DSP, the ascribed Figure of Merit (FOM) at 125keV ee (± 10keV ee ) increased from 0.95 to 1.02 at 125MSPS. At 300keV ee and above, all the FOMs are better than 2.00. Our study suggests that 250MSPS is a good enough sampling rate for neutron-gamma discrimination in this system in order to be sensitive to neutrons at and above ~ 125keV ee . Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Sample size requirements for studies of treatment effects on beta-cell function in newly diagnosed type 1 diabetes.

    Science.gov (United States)

    Lachin, John M; McGee, Paula L; Greenbaum, Carla J; Palmer, Jerry; Pescovitz, Mark D; Gottlieb, Peter; Skyler, Jay

    2011-01-01

    Preservation of β-cell function as measured by stimulated C-peptide has recently been accepted as a therapeutic target for subjects with newly diagnosed type 1 diabetes. In recently completed studies conducted by the Type 1 Diabetes Trial Network (TrialNet), repeated 2-hour Mixed Meal Tolerance Tests (MMTT) were obtained for up to 24 months from 156 subjects with up to 3 months duration of type 1 diabetes at the time of study enrollment. These data provide the information needed to more accurately determine the sample size needed for future studies of the effects of new agents on the 2-hour area under the curve (AUC) of the C-peptide values. The natural log(x), log(x+1) and square-root (√x) transformations of the AUC were assessed. In general, a transformation of the data is needed to better satisfy the normality assumptions for commonly used statistical tests. Statistical analysis of the raw and transformed data are provided to estimate the mean levels over time and the residual variation in untreated subjects that allow sample size calculations for future studies at either 12 or 24 months of follow-up and among children 8-12 years of age, adolescents (13-17 years) and adults (18+ years). The sample size needed to detect a given relative (percentage) difference with treatment versus control is greater at 24 months than at 12 months of follow-up, and differs among age categories. Owing to greater residual variation among those 13-17 years of age, a larger sample size is required for this age group. Methods are also described for assessment of sample size for mixtures of subjects among the age categories. Statistical expressions are presented for the presentation of analyses of log(x+1) and √x transformed values in terms of the original units of measurement (pmol/ml). Analyses using different transformations are described for the TrialNet study of masked anti-CD20 (rituximab) versus masked placebo. These results provide the information needed to accurately

  15. Sample size requirements for studies of treatment effects on beta-cell function in newly diagnosed type 1 diabetes.

    Directory of Open Access Journals (Sweden)

    John M Lachin

    Full Text Available Preservation of β-cell function as measured by stimulated C-peptide has recently been accepted as a therapeutic target for subjects with newly diagnosed type 1 diabetes. In recently completed studies conducted by the Type 1 Diabetes Trial Network (TrialNet, repeated 2-hour Mixed Meal Tolerance Tests (MMTT were obtained for up to 24 months from 156 subjects with up to 3 months duration of type 1 diabetes at the time of study enrollment. These data provide the information needed to more accurately determine the sample size needed for future studies of the effects of new agents on the 2-hour area under the curve (AUC of the C-peptide values. The natural log(x, log(x+1 and square-root (√x transformations of the AUC were assessed. In general, a transformation of the data is needed to better satisfy the normality assumptions for commonly used statistical tests. Statistical analysis of the raw and transformed data are provided to estimate the mean levels over time and the residual variation in untreated subjects that allow sample size calculations for future studies at either 12 or 24 months of follow-up and among children 8-12 years of age, adolescents (13-17 years and adults (18+ years. The sample size needed to detect a given relative (percentage difference with treatment versus control is greater at 24 months than at 12 months of follow-up, and differs among age categories. Owing to greater residual variation among those 13-17 years of age, a larger sample size is required for this age group. Methods are also described for assessment of sample size for mixtures of subjects among the age categories. Statistical expressions are presented for the presentation of analyses of log(x+1 and √x transformed values in terms of the original units of measurement (pmol/ml. Analyses using different transformations are described for the TrialNet study of masked anti-CD20 (rituximab versus masked placebo. These results provide the information needed to

  16. Measurement of radioactivity in the environment - Soil - Part 2: Guidance for the selection of the sampling strategy, sampling and pre-treatment of samples

    International Nuclear Information System (INIS)

    2007-01-01

    This part of ISO 18589 specifies the general requirements, based on ISO 11074 and ISO/IEC 17025, for all steps in the planning (desk study and area reconnaissance) of the sampling and the preparation of samples for testing. It includes the selection of the sampling strategy, the outline of the sampling plan, the presentation of general sampling methods and equipment, as well as the methodology of the pre-treatment of samples adapted to the measurements of the activity of radionuclides in soil. This part of ISO 18589 is addressed to the people responsible for determining the radioactivity present in soil for the purpose of radiation protection. It is applicable to soil from gardens, farmland, urban or industrial sites, as well as soil not affected by human activities. This part of ISO 18589 is applicable to all laboratories regardless of the number of personnel or the range of the testing performed. When a laboratory does not undertake one or more of the activities covered by this part of ISO 18589, such as planning, sampling or testing, the corresponding requirements do not apply. Information is provided on scope, normative references, terms and definitions and symbols, principle, sampling strategy, sampling plan, sampling process, pre-treatment of samples and recorded information. Five annexes inform about selection of the sampling strategy according to the objectives and the radiological characterization of the site and sampling areas, diagram of the evolution of the sample characteristics from the sampling site to the laboratory, example of sampling plan for a site divided in three sampling areas, example of a sampling record for a single/composite sample and example for a sample record for a soil profile with soil description. A bibliography is provided

  17. [Utilization of self-sampling kits for HPV testing in cervical cancer screening - pilot study].

    Science.gov (United States)

    Ondryášová, H; Koudeláková, V; Drábek, J; Vaněk, P; Slavkovský, R; Hajdúch, M

    2015-12-01

    To get initial experience with alternative sampling (self-sampling) for HPV testing as the means of cervical cancer screening program. Original work. Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University in Olomouc. Based on expression of interest, 215 self-sampling kits were posted to women. Evalyn(®) Brush Vaginal swabs obtained by self-sampling were analyzed for the presence of HPV infection by Cobas 4800 HPV (Roche) followed by genotyping using PapilloCheck(®) HPV-Screening (Greiner Bio-One). Sixty women randomly chosen from our sample were sent a questionnaire focused on their experience with self-sampling. One hundred seventy-four of 215 (81%) distributed self-sampling devices have been delivered to analysis. All cervicovaginal swabs were sampled correctly and it was possible to analyze them by Cobas 4800 HPV test. Similarly, 98% (171/174) samples were analyzable by PapilloCheck(®) HPV-Screening.One hundred twenty-five (72%) of 174 tested samples were HPV negative. Low risk HPV infection was detected only in 7 samples (4%), and high risk HPV (hrHPV) infection was present in 42 samples (24%). The most frequently detected hrHPV genotypes were HPV16 (11/42; 26%) and HPV53 (6/42; 14%). HrHPV co-infection was detected in 10 cases, in 5 of them lrHPV infection was find also.Of the 60 questionnaires, 48 (80%) were returned. From this group, 47 (98%) women rated their experience with self-sampling device as good to excellent. User manual of self-sampling device was considered good to excellent by all women (100%). All women also rated the convenience of self-sampling device using as good to excellent. As expected, most of the women (n = 42 [88%]) preferred self-sampling to physician sampling. Cervicovaginal self-sampling leads to valid results of HPV screening using two molecular genetics methods and was accepted by Czech women very well. The self-sampling as an opportunity to participate in cervical cancer

  18. Anthracene as a Non-hygroscopic Diluting Agent for Moessbauer Spectroscopy of Silicate Samples in Moisture-Uptake Studies

    International Nuclear Information System (INIS)

    Hoffman, E. J.; Bickraj, K.; Denalli, C.

    2004-01-01

    Anthracene gained no mass when held in a humid chamber and showed no gamma absorption and so appears to be suitable as a replacement for sugars for dilution of moisture-sensitive 57 Fe-Moessbauer spectroscopy samples. Applied to studies of moisture effects on a circumstellar silicate dust simulant, anthracene permitted preparation of sample series for experimental determination of optimal 57 Fe-Moessbauer areal density.

  19. Preparation of Samples for Leaf Architecture Studies, A Method for Mounting Cleared Leaves

    Directory of Open Access Journals (Sweden)

    Alejandra Vasco

    2014-09-01

    Full Text Available Premise of the study: Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. Methods and Results: Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. Conclusions: The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration.

  20. Prevalence study of compulsive buying in a sample with low individual monthly income.

    Science.gov (United States)

    Leite, Priscilla Lourenço; Silva, Adriana Cardoso

    2015-01-01

    Compulsive buying can be characterized as an almost irresistible impulse to acquire various items. This is a current issue and the prevalence rate in the global population is around 5 to 8%. Some surveys indicate that the problem is growing in young and low-income populations. To evaluate the prevalence of compulsive buying among people with low personal monthly incomes and analyze relationships with socio-demographic data. The Compulsive Buying Scale was administered to screen for compulsive buying and the Hospital Anxiety and Depression Scale was used to assess anxiety and depression in a sample of 56 participants. Pearson coefficients were used to test for correlations. The results indicated that 44.6% presented an average family income equal to or greater than 2.76 minimum wages. It is possible that compulsive buying is not linked to the purchasing power since it was found in a low-income population. Despite the small sample, the results of this study are important for understanding the problem in question.

  1. A Descriptive Study of Pediatric Injury Patterns from the National Automotive Sampling System

    Science.gov (United States)

    Newgard, C; Jolly, BT

    1998-01-01

    This study describes information from the National Automotive Sampling System for injury mechanisms in the pediatric age group (age 0–16). The total number of pediatric cases in the NASS database for this three year sampling period is 2141(weighted 591,084). No restraint use was identified in 23–43% of the children. For age < 1yr, 60% of patients suffer a facial injury. Head injuries make up only 10% of the total injuries, but are severe. For those age 1–4 yrs abdominal injuries and lower extremity injuries begin to appear. For those age 5–10 yrs, the predominant change over younger occupants is the proportion of spinal injuries. By age 11–16, injuries to the spine, upper extremities, and lower extremities outnumber injuries to the face and head. However, in this population, the greatest proportions of AIS 3–5 injuries still occur to the head and abdomen.

  2. Online respondent-driven sampling for studying contact patterns relevant for the spread of close-contact pathogens : A pilot study in Thailand

    NARCIS (Netherlands)

    Stein, Mart L.; van Steenbergen, Jim E.; Chanyasanha, Charnchudhi; Tipayamongkholgul, Mathuros; Buskens, Vincent; van der Heijden, Peter G. M.; Sabaiwan, Wasamon; Bengtsson, Linus; Lu, Xin; Thorson, Anna E.; Kretzschmar, Mirjam E. E.

    2014-01-01

    Background: Information on social interactions is needed to understand the spread of airborne infections through a population. Previous studies mostly collected egocentric information of independent respondents with self-reported information about contacts. Respondent-driven sampling (RDS) is a

  3. A resolution study for electrostatic force microscopy on bimetallic samples using the boundary element method

    International Nuclear Information System (INIS)

    Shen Yongxing; Lee, Minhwan; Lee, Wonyoung; Barnett, David M; Pinsky, Peter M; Prinz, Friedrich B

    2008-01-01

    Electrostatic force microscopy (EFM) is a special design of non-contact atomic force microscopy used for detecting electrostatic interactions between the probe tip and the sample. Its resolution is limited by the finite probe size and the long-range characteristics of electrostatic forces. Therefore, quantitative analysis is crucial to understanding the relationship between the actual local surface potential distribution and the quantities obtained from EFM measurements. To study EFM measurements on bimetallic samples with surface potential inhomogeneities as a special case, we have simulated such measurements using the boundary element method and calculated the force component and force gradient component that would be measured by amplitude modulation (AM) EFM and frequency modulation (FM) EFM, respectively. Such analyses have been performed for inhomogeneities of various shapes and sizes, for different tip-sample separations and tip geometries, for different applied voltages, and for different media (e.g., vacuum or water) in which the experiment is performed. For a sample with a surface potential discontinuity, the FM-EFM resolution expression agrees with the literature; however, the simulation for AM-EFM suggests the existence of an optimal tip radius of curvature in terms of resolution. On the other hand, for samples with strip- and disk-shaped surface potential inhomogeneities, we have obtained quantitative expressions for the detectability size requirements as a function of experimental conditions for both AM- and FM-EFMs, which suggest that a larger tip radius of curvature is moderately favored for detecting the presence of such inhomogeneities

  4. Comparing Respondent-Driven Sampling and Targeted Sampling Methods of Recruiting Injection Drug Users in San Francisco

    Science.gov (United States)

    Malekinejad, Mohsen; Vaudrey, Jason; Martinez, Alexis N.; Lorvick, Jennifer; McFarland, Willi; Raymond, H. Fisher

    2010-01-01

    The objective of this article is to compare demographic characteristics, risk behaviors, and service utilization among injection drug users (IDUs) recruited from two separate studies in San Francisco in 2005, one which used targeted sampling (TS) and the other which used respondent-driven sampling (RDS). IDUs were recruited using TS (n = 651) and RDS (n = 534) and participated in quantitative interviews that included demographic characteristics, risk behaviors, and service utilization. Prevalence estimates and 95% confidence intervals (CIs) were calculated to assess whether there were differences in these variables by sampling method. There was overlap in 95% CIs for all demographic variables except African American race (TS: 45%, 53%; RDS: 29%, 44%). Maps showed that the proportion of IDUs distributed across zip codes were similar for the TS and RDS sample, with the exception of a single zip code that was more represented in the TS sample. This zip code includes an isolated, predominantly African American neighborhood where only the TS study had a field site. Risk behavior estimates were similar for both TS and RDS samples, although self-reported hepatitis C infection was lower in the RDS sample. In terms of service utilization, more IDUs in the RDS sample reported no recent use of drug treatment and syringe exchange program services. Our study suggests that perhaps a hybrid sampling plan is best suited for recruiting IDUs in San Francisco, whereby the more intensive ethnographic and secondary analysis components of TS would aid in the planning of seed placement and field locations for RDS. PMID:20582573

  5. Distance sampling methods and applications

    CERN Document Server

    Buckland, S T; Marques, T A; Oedekoven, C S

    2015-01-01

    In this book, the authors cover the basic methods and advances within distance sampling that are most valuable to practitioners and in ecology more broadly. This is the fourth book dedicated to distance sampling. In the decade since the last book published, there have been a number of new developments. The intervening years have also shown which advances are of most use. This self-contained book covers topics from the previous publications, while also including recent developments in method, software and application. Distance sampling refers to a suite of methods, including line and point transect sampling, in which animal density or abundance is estimated from a sample of distances to detected individuals. The book illustrates these methods through case studies; data sets and computer code are supplied to readers through the book’s accompanying website.  Some of the case studies use the software Distance, while others use R code. The book is in three parts.  The first part addresses basic methods, the ...

  6. Methodology Series Module 5: Sampling Strategies

    OpenAIRE

    Setia, Maninder Singh

    2016-01-01

    Once the research question and the research design have been finalised, it is important to select the appropriate sample for the study. The method by which the researcher selects the sample is the ? Sampling Method?. There are essentially two types of sampling methods: 1) probability sampling ? based on chance events (such as random numbers, flipping a coin etc.); and 2) non-probability sampling ? based on researcher's choice, population that accessible & available. Some of the non-probabilit...

  7. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    Science.gov (United States)

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  8. DWPF Sample Vial Insert Study-Statistical Analysis of DWPF Mock-Up Test Data

    International Nuclear Information System (INIS)

    Harris, S.P.

    1997-01-01

    This report is prepared as part of Technical/QA Task Plan WSRC-RP-97-351 which was issued in response to Technical Task Request HLW/DWPF/TTR-970132 submitted by DWPF. Presented in this report is a statistical analysis of DWPF Mock-up test data for evaluation of two new analytical methods which use insert samples from the existing HydragardTM sampler. The first is a new hydrofluoric acid based method called the Cold Chemical Method (Cold Chem) and the second is a modified fusion method.Both new methods use the existing HydragardTM sampler to collect a smaller insert sample from the process sampling system. The insert testing methodology applies to the DWPF Slurry Mix Evaporator (SME) and the Melter Feed Tank (MFT) samples. Samples in small 3 ml containers (Inserts) are analyzed by either the cold chemical method or a modified fusion method. The current analytical method uses a HydragardTM sample station to obtain nearly full 15 ml peanut vials. The samples are prepared by a multi-step process for Inductively Coupled Plasma (ICP) analysis by drying, vitrification, grinding and finally dissolution by either mixed acid or fusion. In contrast, the insert sample is placed directly in the dissolution vessel, thus eliminating the drying, vitrification and grinding operations for the Cold chem method. Although the modified fusion still requires drying and calcine conversion, the process is rapid due to the decreased sample size and that no vitrification step is required.A slurry feed simulant material was acquired from the TNX pilot facility from the test run designated as PX-7.The Mock-up test data were gathered on the basis of a statistical design presented in SRT-SCS-97004 (Rev. 0). Simulant PX-7 samples were taken in the DWPF Analytical Cell Mock-up Facility using 3 ml inserts and 15 ml peanut vials. A number of the insert samples were analyzed by Cold Chem and compared with full peanut vial samples analyzed by the current methods. The remaining inserts were analyzed by

  9. Required sample size for monitoring stand dynamics in strict forest reserves: a case study

    Science.gov (United States)

    Diego Van Den Meersschaut; Bart De Cuyper; Kris Vandekerkhove; Noel Lust

    2000-01-01

    Stand dynamics in European strict forest reserves are commonly monitored using inventory densities of 5 to 15 percent of the total surface. The assumption that these densities guarantee a representative image of certain parameters is critically analyzed in a case study for the parameters basal area and stem number. The required sample sizes for different accuracy and...

  10. Gridsampler – A Simulation Tool to Determine the Required Sample Size for Repertory Grid Studies

    Directory of Open Access Journals (Sweden)

    Mark Heckmann

    2017-01-01

    Full Text Available The repertory grid is a psychological data collection technique that is used to elicit qualitative data in the form of attributes as well as quantitative ratings. A common approach for evaluating multiple repertory grid data is sorting the elicited bipolar attributes (so called constructs into mutually exclusive categories by means of content analysis. An important question when planning this type of study is determining the sample size needed to a discover all attribute categories relevant to the field and b yield a predefined minimal number of attributes per category. For most applied researchers who collect multiple repertory grid data, programming a numeric simulation to answer these questions is not feasible. The gridsampler software facilitates determining the required sample size by providing a GUI for conducting the necessary numerical simulations. Researchers can supply a set of parameters suitable for the specific research situation, determine the required sample size, and easily explore the effects of changes in the parameter set.

  11. Manual versus automated blood sampling

    DEFF Research Database (Denmark)

    Teilmann, A C; Kalliokoski, Otto; Sørensen, Dorte B

    2014-01-01

    Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters......, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal...... corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters...

  12. A multicenter study of viable PCR using propidium monoazide to detect Legionella in water samples.

    Science.gov (United States)

    Scaturro, Maria; Fontana, Stefano; Dell'eva, Italo; Helfer, Fabrizia; Marchio, Michele; Stefanetti, Maria Vittoria; Cavallaro, Mario; Miglietta, Marilena; Montagna, Maria Teresa; De Giglio, Osvalda; Cuna, Teresa; Chetti, Leonarda; Sabattini, Maria Antonietta Bucci; Carlotti, Michela; Viggiani, Mariagabriella; Stenico, Alberta; Romanin, Elisa; Bonanni, Emma; Ottaviano, Claudio; Franzin, Laura; Avanzini, Claudio; Demarie, Valerio; Corbella, Marta; Cambieri, Patrizia; Marone, Piero; Rota, Maria Cristina; Bella, Antonino; Ricci, Maria Luisa

    2016-07-01

    Legionella quantification in environmental samples is overestimated by qPCR. Combination with a viable dye, such as Propidium monoazide (PMA), could make qPCR (named then vPCR) very reliable. In this multicentre study 717 artificial water samples, spiked with fixed concentrations of Legionella and interfering bacterial flora, were analysed by qPCR, vPCR and culture and data were compared by statistical analysis. A heat-treatment at 55 °C for 10 minutes was also performed to obtain viable and not-viable bacteria. When data of vPCR were compared with those of culture and qPCR, statistical analysis showed significant differences (P 0.05). Overall this study provided a good experimental reproducibility of vPCR but also highlighted limits of PMA in the discriminating capability of dead and live bacteria, making vPCR not completely reliable. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. DNA cards: determinants of DNA yield and quality in collecting genetic samples for pharmacogenetic studies.

    Science.gov (United States)

    Mas, Sergi; Crescenti, Anna; Gassó, Patricia; Vidal-Taboada, Jose M; Lafuente, Amalia

    2007-08-01

    As pharmacogenetic studies frequently require establishment of DNA banks containing large cohorts with multi-centric designs, inexpensive methods for collecting and storing high-quality DNA are needed. The aims of this study were two-fold: to compare the amount and quality of DNA obtained from two different DNA cards (IsoCode Cards or FTA Classic Cards, Whatman plc, Brentford, Middlesex, UK); and to evaluate the effects of time and storage temperature, as well as the influence of anticoagulant ethylenediaminetetraacetic acid on the DNA elution procedure. The samples were genotyped by several methods typically used in pharmacogenetic studies: multiplex PCR, PCR-restriction fragment length polymorphism, single nucleotide primer extension, and allelic discrimination assay. In addition, they were amplified by whole genome amplification to increase genomic DNA mass. Time, storage temperature and ethylenediaminetetraacetic acid had no significant effects on either DNA card. This study reveals the importance of drying blood spots prior to isolation to avoid haemoglobin interference. Moreover, our results demonstrate that re-isolation protocols could be applied to increase the amount of DNA recovered. The samples analysed were accurately genotyped with all the methods examined herein. In conclusion, our study shows that both DNA cards, IsoCode Cards and FTA Classic Cards, facilitate genetic and pharmacogenetic testing for routine clinical practice.

  14. Interpreting plant-sampled ¿14CO2 to study regional anthropogenic CO2 signals in Europe

    OpenAIRE

    Bozhinova, D.N.

    2015-01-01

    "Interpreting plant-sampled Δ14CO2 to study regional anthropogenic CO2 signals in Europe" Author: Denica Bozhinova This thesis investigates the quantitative interpretation of plant-sampled ∆14CO2 as an indicator of fossil fuel CO2 recently added to the atmosphere. We present a methodology to calculate the ∆14CO2 that has accumulated in a plant over its growing period, based on a modeling framework consisting of a plant growth model (SUCROS) and an atmospheric transport model (WRF-Chem). We ve...

  15. Sampling and chemical analysis in environmental samples around Nuclear Power Plants and some environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2002-12-15

    Twelve kinds of environmental samples such as soil, seawater, underground water, etc. around Nuclear Power Plants(NPPs) were collected. Tritium chemical analysis was tried for the samples of rain water, pine-needle, air, seawater, underground water, chinese cabbage, a grain of rice and milk sampled around NPPs, and surface seawater and rain water sampled over the country. Strontium in the soil that sere sampled at 60 point of district in Korea were analyzed. Tritium were sampled at 60 point of district in Korea were analyzed. Tritium were analyzed in 21 samples of surface seawater around the Korea peninsular that were supplied from KFRDI(National Fisheries Research and Development Institute). Sampling and chemical analysis environmental samples around Kori, Woolsung, Youngkwang, Wooljin Npps and Taeduk science town for tritium and strontium analysis was managed according to plans. Succeed to KINS after all samples were tried.

  16. Study of C-MYC amplification and expression in Iranian gastric cancer samples using CISH and IHC methods.

    Science.gov (United States)

    Khaleghian, Malihea; Jahanzad, Issa; Shakoori, Abbas; Ardalan, Farid Azmoudeh; Azimi, Cyrus

    2015-01-01

    Gastric cancer is the fourth most frequent malignancy and the second cause of cancer-related mortality worldwide. It has been suggested that in gastric carcinogenesis, the C-MYC gene has an important function. The objective of this study is to establish the preference of Chromogenic in situ hybridization (CISH) and Immunohistochemistry (IHC) in the diagnosis and prognosis of gastric cancer. Samples comprised of 50 randomly selected patients of whom 40 were male and 10 female. To evaluate the MYC copy number and its protein expression, CISH and IHC analyses were performed for 50 gastric adenocarcinomas, in Iran. The location of the tumor in 64% of the patients was the fundus, and in 72% of patients, the tumors were of a diffuse type; 22 samples showed no amplification, and 28 samples were with amplification. MYC immunoreactivity was observed in 13 samples. Twelve samples showed both MYC amplification and MYC immunoreactivity. In addition, among the 28 CISH+ samples, 12 samples had positive signals for IHC and 16 samples had negative signals for IHC. A majority of the IHC-negative patients had no amplification, but only one patient with IHC positive had no amplification. Our conclusion was that for the management and treatment of gastric cancer, and for special attention of clinicians, for prognosis and tumor progression, the CISH was a better and more feasible test than IHC, in regard to the sensitivity and specificity.

  17. Study of C-MYC amplification and expression in Iranian gastric cancer samples using CISH and IHC methods

    Directory of Open Access Journals (Sweden)

    Malihea Khaleghian

    2015-01-01

    Full Text Available Background: Gastric cancer is the fourth most frequent malignancy and the second cause of cancer-related mortality worldwide. It has been suggested that in gastric carcinogenesis, the C-MYC gene has an important function. The objective of this study is to establish the preference of Chromogenic in situ hybridization (CISH and Immunohistochemistry (IHC in the diagnosis and prognosis of gastric cancer. Materials and Methods: Samples comprised of 50 randomly selected patients of whom 40 were male and 10 female. To evaluate the MYC copy number and its protein expression, CISH and IHC analyses were performed for 50 gastric adenocarcinomas, in Iran. Results: The location of the tumor in 64% of the patients was the fundus, and in 72% of patients, the tumors were of a diffuse type; 22 samples showed no amplification, and 28 samples were with amplification. MYC immunoreactivity was observed in 13 samples. Twelve samples showed both MYC amplification and MYC immunoreactivity. In addition, among the 28 CISH+ samples, 12 samples had positive signals for IHC and 16 samples had negative signals for IHC. A majority of the IHC-negative patients had no amplification, but only one patient with IHC positive had no amplification. Conclusion: Our conclusion was that for the management and treatment of gastric cancer, and for special attention of clinicians, for prognosis and tumor progression, the CISH was a better and more feasible test than IHC, in regard to the sensitivity and specificity.

  18. NGSCheckMate: software for validating sample identity in next-generation sequencing studies within and across data types.

    Science.gov (United States)

    Lee, Sejoon; Lee, Soohyun; Ouellette, Scott; Park, Woong-Yang; Lee, Eunjung A; Park, Peter J

    2017-06-20

    In many next-generation sequencing (NGS) studies, multiple samples or data types are profiled for each individual. An important quality control (QC) step in these studies is to ensure that datasets from the same subject are properly paired. Given the heterogeneity of data types, file types and sequencing depths in a multi-dimensional study, a robust program that provides a standardized metric for genotype comparisons would be useful. Here, we describe NGSCheckMate, a user-friendly software package for verifying sample identities from FASTQ, BAM or VCF files. This tool uses a model-based method to compare allele read fractions at known single-nucleotide polymorphisms, considering depth-dependent behavior of similarity metrics for identical and unrelated samples. Our evaluation shows that NGSCheckMate is effective for a variety of data types, including exome sequencing, whole-genome sequencing, RNA-seq, ChIP-seq, targeted sequencing and single-cell whole-genome sequencing, with a minimal requirement for sequencing depth (>0.5X). An alignment-free module can be run directly on FASTQ files for a quick initial check. We recommend using this software as a QC step in NGS studies. https://github.com/parklab/NGSCheckMate. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  19. Data Quality Objectives For Selecting Waste Samples For Bench-Scale Reformer Treatability Studies

    International Nuclear Information System (INIS)

    Banning, D.L.

    2011-01-01

    This document describes the data quality objectives to select archived samples located at the 222-S Laboratory for Bench-Scale Reforming testing. The type, quantity, and quality of the data required to select the samples for Fluid Bed Steam Reformer testing are discussed. In order to maximize the efficiency and minimize the time to treat Hanford tank waste in the Waste Treatment and Immobilization Plant, additional treatment processes may be required. One of the potential treatment processes is the fluidized bed steam reformer. A determination of the adequacy of the fluidized bed steam reformer process to treat Hanford tank waste is required. The initial step in determining the adequacy of the fluidized bed steam reformer process is to select archived waste samples from the 222-S Laboratory that will be used in a bench scale tests. Analyses of the selected samples will be required to confirm the samples meet the shipping requirements and for comparison to the bench scale reformer (BSR) test sample selection requirements.

  20. Sampling method of water sources at study site Taiping, Perak and Pulau Burung, Penang for research on pollutant movement in underground water

    International Nuclear Information System (INIS)

    Mohd Rifaie Mohd Murtadza; Mohd Tadza Abdul Rahman; Kamarudin Samuding; Roslanzairi Mostapa

    2005-01-01

    This paperwork explain the method of water sampling being used to take the water samples from the study sites in Taiping, Perak and Pulau Burung, Pulau Pinang. The sampling involve collecting of water samples for groundwater from boreholes and surface water from canal, river, pond, and ex-mining pond from several locations at the study sites. This study also elaborates the instruments and chemical used. The main purpose of this sampling are to obtain the important water quality parameters such as pH, conductivity, Total Dissolved Solid (TDS), heavy metals, anions, cations, and environmental isotopes delta values (d) for 18O, Deuterium dan Tritium. A correct sampling method according to standard is very important to ensure an accurate and precise results. With this, the data from the laboratory tests result can be fully utilized to make the interpretation of the pollutants movement. (Author)

  1. The Adrenal Vein Sampling International Study (AVIS) for identifying the major subtypes of primary aldosteronism.

    NARCIS (Netherlands)

    Rossi, G.P.; Barisa, M.; Allolio, B.; Auchus, R.J.; Amar, L.; Cohen, D.; Degenhart, C.; Deinum, J.; Fischer, E.; Gordon, R.; Kickuth, R.; Kline, G.; Lacroix, A.; Magill, S.; Miotto, D.; Naruse, M.; Nishikawa, T.; Omura, M.; Pimenta, E.; Plouin, P.F.; Quinkler, M.; Reincke, M.; Rossi, E.; Rump, L.C.; Satoh, F.; Schultze Kool, L.J.; Seccia, T.M.; Stowasser, M.; Tanabe, A.; Trerotola, S.; Vonend, O.; Widimsky Jr, J.; Wu, K.D.; Wu, V.C.; Pessina, A.C.

    2012-01-01

    CONTEXT: In patients who seek surgical cure of primary aldosteronism (PA), The Endocrine Society Guidelines recommend the use of adrenal vein sampling (AVS), which is invasive, technically challenging, difficult to interpret, and commonly held to be risky. OBJECTIVE: The aim of this study was to

  2. Study of /sup 210/Pb and /sup 210/Po distributions in environmental samples by CR-39 track detector

    Energy Technology Data Exchange (ETDEWEB)

    Hunyadi, I.; Somogyi, G.; Szilagyi, S. (Magyar Tudomanyos Akademia, Debrecen. Atommag Kutato Intezete)

    1984-01-01

    Activity concentration distributions of long-lived alpha-emitters in aerosol samples are analysed by high-resolution autoradiography in CR-39. A study of the alpha-activity attached to aerosols of different particulate sizes separated by a cascade impactor is also performed. It is found that, in the majority of samples, the alpha-activity can be dominantly related to the presence of /sup 210/Po produced by its beta-active precursor /sup 210/Pb. In our studies we have applied the following methods: 1) analysis of alpha-decay properties by means of autoradiographs taken at different post-sampling times, 2) spectroscopical study of individual alpha-tracks and track clusters by a method developed by us for high-resolution alpha-energy determination. In the second method the parameters to be measured are the major axis of surface track opening, the diameter of etched out track end, the total length measurable on the surface along the projected track, and the thickness of layer etched away from the detector surface.

  3. Systematic Sampling and Cluster Sampling of Packet Delays

    OpenAIRE

    Lindh, Thomas

    2006-01-01

    Based on experiences of a traffic flow performance meter this papersuggests and evaluates cluster sampling and systematic sampling as methods toestimate average packet delays. Systematic sampling facilitates for exampletime analysis, frequency analysis and jitter measurements. Cluster samplingwith repeated trains of periodically spaced sampling units separated by randomstarting periods, and systematic sampling are evaluated with respect to accuracyand precision. Packet delay traces have been ...

  4. Sample pretretment in microsystems

    DEFF Research Database (Denmark)

    Perch-Nielsen, Ivan R.

    2003-01-01

    : Sample preparation → DNA amplification → DNA analysis. The overall goal of the project is integration of as many as possible of these steps. This thesis covers mainly pretreatment in a microchip. Some methods for sample pretreatment have been tested. Most conventional is fluorescence activated cell sort......When a sample, e.g. from a patient, is processed using conventional methods, the sample must be transported to the laboratory where it is analyzed, after which the results is sent back. By integrating the separate steps of the analysis in a micro total analysis system (μTAS), results can...... be obtained fast and better. Preferably with all the processes from sample to signal moved to the bedside of the patient. Of course there is still much to learn and study in the process of miniaturization. DNA analysis is one process subject to integration. There are roughly three steps in a DNA analysis...

  5. Detoxification Of Ochratoxin AIN Green Coffee Beans By Physical Methods With Studying Genotoxicity Of Treated Samples

    International Nuclear Information System (INIS)

    FARAG, S.A.; SHAMS EL DIEEN, N.M.M.; EL-SIDEEK, L

    2010-01-01

    Ochratoxin A (OTA) is potently nephrotoxic, teratogenic and carcinogenic, and the potency was varied markedly between species and sexes. Unfortunately, OTA are present due to mold contamination in different food stuffs such as coffee bean, therefore, the present study was carried out on collected imported coffee samples from super markets in Egypt. The isolation and identification proved presence of Penicilli sp. and Aspergillus sp. whereas the last one was dominant in two samples as A. niger and A. ochoruses. Determination of OTA by using HPLC analysis showed presence of high levels than the allowance levels in green coffee beans (more than 5 μg/kg; ppb). In addition, another group of collected samples as roasted coffee beans indicated the presence of high toxic concentrations of OTA. The study was then conducted on samples contain the highest OTA content by using some physical methods as gamma irradiation (5 and 10 kGy), charcoal (powder, granules), roasting (at 200 0 C for 7-10 min and 20 min). The results showed that proposed physical methods, mainly gamma irradiation and charcoal, could be efficient to decrease OTA in green beans coffee without produce toxic substance as well as non-significant changes in its properties. In addition, safety of resulted coffee beans after treatments were checked by ESR and genotoxicity test, which raise the preferability of gamma irradiation (10 kGy) treatment before using medium roasting to get coffee beans free from OTA

  6. Sample size computation for association studies using case–parents ...

    Indian Academy of Sciences (India)

    ple size needed to reach a given power (Knapp 1999; Schaid. 1999; Chen and Deng 2001; Brown 2004). In their seminal paper, Risch and Merikangas (1996) showed that for a mul- tiplicative mode of inheritance (MOI) for the susceptibility gene, sample size depends on two parameters: the frequency of the risk allele at the ...

  7. Electromagnetic Navigational Bronchoscopy versus CT-guided Percutaneous Sampling of Peripheral Indeterminate Pulmonary Nodules: A Cohort Study.

    Science.gov (United States)

    Bhatt, Kavita M; Tandon, Yasmeen K; Graham, Ruffin; Lau, Charles T; Lempel, Jason K; Azok, Joseph T; Mazzone, Peter J; Schneider, Erika; Obuchowski, Nancy A; Bolen, Michael A

    2018-03-01

    Purpose To compare the diagnostic yield and complication rates of electromagnetic navigational bronchoscopic (ENB)-guided and computed tomography (CT)-guided percutaneous tissue sampling of lung nodules. Materials and Methods Retrospectively identified were 149 patients sampled percutaneously with CT guidance and 146 patients who underwent ENB with transbronchial biopsy of a lung lesion between 2013 and 2015. Clinical data, incidence of complications, and nodule pathologic analyses were assessed through electronic medical record review. Lung nodule characteristics were reviewed through direct image analysis. Molecular marker studies and pathologic analyses from surgical excision were reviewed when available. Multiple-variable logistic regression models were built to compare the diagnostic yield and complication rates for each method and for different patient and disease characteristics. Results CT-guided sampling was more likely to be diagnostic than ENB-guided biopsy (86.0% [129 of 150] vs 66.0% [99 of 150], respectively), and this difference remained significant even after adjustments were made for patient and nodule characteristics (P guided sampling (P guided sampling, 88.9% [32 of 36]; CT-guided sampling, 82.0% [41 of 50]). The two groups had similar rates of major complications (symptomatic hemorrhage, P > .999; pneumothorax requiring chest tube and/or admission, P = .417). Conclusion CT-guided transthoracic biopsy provided higher diagnostic yield in the assessment of peripheral pulmonary nodules than navigational bronchoscopy with a similar rate of clinically relevant complications. © RSNA, 2017 Online supplemental material is available for this article.

  8. Study of the Gamma Radiation Effect on Tannins Samples

    International Nuclear Information System (INIS)

    Coto Hernandez, I.; Barroso Solares, S.; Martinez Luzardo, F.; Guzman Martinez, F.; Diaz Rizo, O.; Arado Lopez, J.O.; Santana Romero, J.L.; Baeza Fonte, A.; Rapado Paneque, M.; Garcia, F.

    2011-01-01

    Vegetable tannins are polyphenolic substances of different chemical mixtures, in correspondence with the characteristics of groups of polyphenols. Taking into consideration its composition, we can find different types of flavonoids, mainly in the so-called condensed tannins. In general, many applications have been explored, including the medical ones, due to their proven biological activity as antiviral, antibacterial and others characteristics derived from their reactions with metal ions and amino acids of the protein components. Therefore it is promising to examine the effects of gamma radiation on the structure of tannin, looking for the possible modification of its biological activity. To this end, samples of tannins are irradiated at different doses (maximum dose 35 kGy) with the use of a Cobalt-60 irradiator. Scanning Electron Microscopy (SEM) permitted to characterize the samples in morphology and composition. The changes were analyzed by using infrared spectroscopy Fourier transform (FT-IR) and High Resolution Liquid Chromatography (HPLC). At the end we discuss the implication of the results for a dosage range above 5 kGy. (Author)

  9. Wideband 4-diode sampling circuit

    Science.gov (United States)

    Wojtulewicz, Andrzej; Radtke, Maciej

    2016-09-01

    The objective of this work was to develop a wide-band sampling circuit. The device should have the ability to collect samples of a very fast signal applied to its input, strengthen it and prepare for further processing. The study emphasizes the method of sampling pulse shaping. The use of ultrafast pulse generator allows sampling signals with a wide frequency spectrum, reaching several gigahertzes. The device uses a pulse transformer to prepare symmetrical pulses. Their final shape is formed with the help of the step recovery diode, two coplanar strips and Schottky diode. Made device can be used in the sampling oscilloscope, as well as other measurement system.

  10. An empirical comparison of respondent-driven sampling, time location sampling, and snowball sampling for behavioral surveillance in men who have sex with men, Fortaleza, Brazil.

    Science.gov (United States)

    Kendall, Carl; Kerr, Ligia R F S; Gondim, Rogerio C; Werneck, Guilherme L; Macena, Raimunda Hermelinda Maia; Pontes, Marta Kerr; Johnston, Lisa G; Sabin, Keith; McFarland, Willi

    2008-07-01

    Obtaining samples of populations at risk for HIV challenges surveillance, prevention planning, and evaluation. Methods used include snowball sampling, time location sampling (TLS), and respondent-driven sampling (RDS). Few studies have made side-by-side comparisons to assess their relative advantages. We compared snowball, TLS, and RDS surveys of men who have sex with men (MSM) in Forteleza, Brazil, with a focus on the socio-economic status (SES) and risk behaviors of the samples to each other, to known AIDS cases and to the general population. RDS produced a sample with wider inclusion of lower SES than snowball sampling or TLS-a finding of health significance given the majority of AIDS cases reported among MSM in the state were low SES. RDS also achieved the sample size faster and at lower cost. For reasons of inclusion and cost-efficiency, RDS is the sampling methodology of choice for HIV surveillance of MSM in Fortaleza.

  11. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study.

    Science.gov (United States)

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A; Chauhan, Sunanda

    2018-01-01

    Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material.

  12. Clinical and anatomic pathology effects of serial blood sampling in rat toxicology studies, using conventional or microsampling methods.

    Science.gov (United States)

    Caron, Alexis; Lelong, Christine; Bartels, T; Dorchies, O; Gury, T; Chalier, Catherine; Benning, Véronique

    2015-08-01

    As a general practice in rodent toxicology studies, satellite animals are used for toxicokinetic determinations, because of the potential impact of serial blood sampling on toxicological endpoints. Besides toxicological and toxicokinetic determinations, blood samples obtained longitudinally from a same animal may be used for the assessment of additional parameters (e.g., metabolism, pharmacodynamics, safety biomarkers) to maximize information that can be deduced from rodents. We investigated whether removal of up to 6 × 200 μL of blood over 24h can be applied in GLP rat toxicology studies without affecting the scientific outcome. 8 week-old female rats (200-300 g) were dosed for up to 1 month with a standard vehicle and subjected or not (controls) to serial blood sampling for sham toxicokinetic/ancillary determinations, using miniaturized methods allowing collection of 6 × 50, 100 or 200 μL over 24h. In-life endpoints, clinical pathology parameters and histopathology of organs sensitive to blood volume reduction were evaluated at several time points after completion of sampling. In sampled rats, minimal and reversible changes in red blood cell mass (maximally 15%) and subtle variations in liver enzymes, fibrinogen and neutrophils were not associated with any organ/tissue macroscopic or microscopic correlate. Serial blood sampling (up to 6 × 200 μL over 24h) is compatible with the assessment of standard toxicity endpoints in adult rats. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Determination of alpha-dose rates and chronostratigraphical study of travertine samples

    International Nuclear Information System (INIS)

    Oufni, L.; University Moulay Ismail, Errachidia; Misdaq, M.A.; Boudad, L.; Kabiri, L.

    2001-01-01

    Uranium and thorium contents in different layers of stratigraphical sedimentary deposits have been evaluated by using LR-115 type II and CR-39 solid state nuclear track detectors (SSNTD). A method has been developed for determining the alpha-dose rates of the sedimentary travertine samples. Using the U/Th dating method, we succeeded in age dating carbonated level sampled in the sedimentary deposits. Correlation between the stratigraphy, alpha-dose rates and age has been investigated. (author)

  14. In-Sample Confidence Bands and Out-of-Sample Forecast Bands for Time-Varying Parameters in Observation Driven Models

    NARCIS (Netherlands)

    Blasques, F.; Koopman, S.J.; Lasak, K.A.; Lucas, A.

    2016-01-01

    We study the performances of alternative methods for calculating in-sample confidence and out-of-sample forecast bands for time-varying parameters. The in-sample bands reflect parameter uncertainty, while the out-of-sample bands reflect not only parameter uncertainty, but also innovation

  15. Does duration of untreated psychosis bias study samples of first-episode psychosis?

    DEFF Research Database (Denmark)

    Friis, S; Melle, I; Larsen, T K

    2004-01-01

    OBJECTIVE: While findings are contradictory, many studies report that long Duration of Untreated Psychosis (DUP) correlates with poorer outcome in first episode psychosis. In an outcome study of first-episode psychosis, we compared the patients who refused to participate in a follow-along with th......OBJECTIVE: While findings are contradictory, many studies report that long Duration of Untreated Psychosis (DUP) correlates with poorer outcome in first episode psychosis. In an outcome study of first-episode psychosis, we compared the patients who refused to participate in a follow......-along with those who consented to estimate the importance of this factor in sample recruitment bias. Our questions were: (i) What is the percentage of refusers? (ii) Are there systematic differences between refusers and consenters on DUP and/or other admission variables? (iii) What is the risk of refusal...... for different values of DUP? METHOD: In an unselected group of consecutively admitted patients we compared follow-along refusers and consenters on the following admission variables: sex, age, diagnostic group, substance abuse, being in-patient, coming from an early detection site and DUP. We conducted...

  16. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  17. Recruiting and Retaining an Ethnically Diverse Sample of Older Adults in a Longitudinal Intervention Study

    Science.gov (United States)

    Austin-Wells, Vonnette; McDougall, Graham J.; Becker, Heather

    2006-01-01

    This paper describes strategies developed to recruit and retain an ethnically diverse sample in a longitudinal intervention of 246 participants in the SeniorWISE study. The ethnic and socioeconomic differences of these participants necessitated the use of different methods of effectively communicating with this population. Recruitment benefited…

  18. Systematic studies of small scintillators for new sampling calorimeter

    International Nuclear Information System (INIS)

    Jacosalem, E.P.; Sanchez, A.L.C.; Bacala, A.M.; Iba, S.; Nakajima, N.; Ono, H.; Miyata, H.

    2007-01-01

    A new sampling calorimeter using very thin scintillators and the multi-pixel photon counter (MPPC) has been proposed to produce better position resolution for the international linear collider (ILC) experiment. As part of this R and D study, small plastic scintillators of different sizes, thickness and wrapping reflectors are systematically studied. The scintillation light due to beta rays from a collimated 90 Sr source are collected from the scintillator by wavelength-shifting (WLS) fiber and converted into electrical signals at the PMT. The wrapped scintillator that gives the best light yield is determined by comparing the measured pulse height of each 10 x 40 x 2 mm strip scintillator covered with 3M reflective mirror film, teflon, white paint, black tape, gold, aluminum and white paint+teflon. The pulse height dependence on position, length and thickness of the 3M reflective mirror film and teflon wrapped scintillators are measured. Results show that the 3M radiant mirror film-wrapped scintillator has the greatest light yield with an average of 9.2 photoelectrons. It is observed that light yield slightly increases with scintillator length, but increases to about 100% when WLS fiber diameter is increased from 1.0 mm to 1.6 mm. The position dependence measurement along the strip scintillator showed the uniformity of light transmission from the sensor to the PMT. A dip across the strip is observed which is 40% of the maximum pulse height. The block type scintillator pulse height, on the other hand, is found to be almost proportional to scintillator thickness. (author)

  19. Water born pollutants sampling using porous suction samples

    International Nuclear Information System (INIS)

    Baig, M.A.

    1997-01-01

    The common standard method of sampling water born pollutants in the vadoze zone is core sampling and it is followed by extraction of pore fluid. This method does not allow sampling at the same location next time and again later on. There is an alternative approach for sampling fluids (water born pollutants) from both saturated and unsaturated regions of vadose zone using porous suction samplers. There are three types of porous suction samplers, vacuum-operated, pressure-vacuum lysimeters, high pressure vacuum samples. The suction samples are operated in the range of 0-70 centi bars and usually consist of ceramic and polytetrafluorethylene (PTFE). The operation range of PTFE is higher than ceramic cups. These samplers are well suited for in situ and repeated sampling form the same location. This paper discusses the physical properties and operating condition of such samplers to the utilized under our environmental sampling. (author)

  20. Choosing a suitable sample size in descriptive sampling

    International Nuclear Information System (INIS)

    Lee, Yong Kyun; Choi, Dong Hoon; Cha, Kyung Joon

    2010-01-01

    Descriptive sampling (DS) is an alternative to crude Monte Carlo sampling (CMCS) in finding solutions to structural reliability problems. It is known to be an effective sampling method in approximating the distribution of a random variable because it uses the deterministic selection of sample values and their random permutation,. However, because this method is difficult to apply to complex simulations, the sample size is occasionally determined without thorough consideration. Input sample variability may cause the sample size to change between runs, leading to poor simulation results. This paper proposes a numerical method for choosing a suitable sample size for use in DS. Using this method, one can estimate a more accurate probability of failure in a reliability problem while running a minimal number of simulations. The method is then applied to several examples and compared with CMCS and conventional DS to validate its usefulness and efficiency

  1. Study of Acoustic Emission and Mechanical Characteristics of Coal Samples under Different Loading Rates

    Directory of Open Access Journals (Sweden)

    Huamin Li

    2015-01-01

    Full Text Available To study the effect of loading rate on mechanical properties and acoustic emission characteristics of coal samples, collected from Sanjiaohe Colliery, the uniaxial compression tests are carried out under various levels of loading rates, including 0.001 mm/s, 0.002 mm/s, and 0.005 mm/s, respectively, using AE-win E1.86 acoustic emission instrument and RMT-150C rock mechanics test system. The results indicate that the loading rate has a strong impact on peak stress and peak strain of coal samples, but the effect of loading rate on elasticity modulus of coal samples is relatively small. When the loading rate increases from 0.001 mm/s to 0.002 mm/s, the peak stress increases from 22.67 MPa to 24.99 MPa, the incremental percentage is 10.23%, and under the same condition the peak strain increases from 0.006191 to 0.007411 and the incremental percentage is 19.71%. Similarly, when the loading rate increases from 0.002 mm/s to 0.005 mm/s, the peak stress increases from 24.99 MPa to 28.01 MPa, the incremental percentage is 12.08%, the peak strain increases from 0.007411 to 0.008203, and the incremental percentage is 10.69%. The relationship between acoustic emission and loading rate presents a positive correlation, and the negative correlation relation has been determined between acoustic emission cumulative counts and loading rate during the rupture process of coal samples.

  2. Study of the concentration of 7 Be in samples of rain water

    International Nuclear Information System (INIS)

    Quintero P, E.; Rojas M, V.P.

    2004-01-01

    This work shows the methodology carried out for the determination of 7 Be in samples of rain water and the obtained results of the concentration of having said radionuclide in this sampled matrix during the last five years in the Nuclear Center of Mexico. (Author)

  3. Spot sputum samples are at least as good as early morning samples for identifying Mycobacterium tuberculosis.

    Science.gov (United States)

    Murphy, Michael E; Phillips, Patrick P J; Mendel, Carl M; Bongard, Emily; Bateson, Anna L C; Hunt, Robert; Murthy, Saraswathi; Singh, Kasha P; Brown, Michael; Crook, Angela M; Nunn, Andrew J; Meredith, Sarah K; Lipman, Marc; McHugh, Timothy D; Gillespie, Stephen H

    2017-10-27

    The use of early morning sputum samples (EMS) to diagnose tuberculosis (TB) can result in treatment delay given the need for the patient to return to the clinic with the EMS, increasing the chance of patients being lost during their diagnostic workup. However, there is little evidence to support the superiority of EMS over spot sputum samples. In this new analysis of the REMoxTB study, we compare the diagnostic accuracy of EMS with spot samples for identifying Mycobacterium tuberculosis pre- and post-treatment. Patients who were smear positive at screening were enrolled into the study. Paired sputum samples (one EMS and one spot) were collected at each trial visit pre- and post-treatment. Microscopy and culture on solid LJ and liquid MGIT media were performed on all samples; those missing corresponding paired results were excluded from the analyses. Data from 1115 pre- and 2995 post-treatment paired samples from 1931 patients enrolled in the REMoxTB study were analysed. Patients were recruited from South Africa (47%), East Africa (21%), India (20%), Asia (11%), and North America (1%); 70% were male, median age 31 years (IQR 24-41), 139 (7%) co-infected with HIV with a median CD4 cell count of 399 cells/μL (IQR 318-535). Pre-treatment spot samples had a higher yield of positive Ziehl-Neelsen smears (98% vs. 97%, P = 0.02) and LJ cultures (87% vs. 82%, P = 0.006) than EMS, but there was no difference for positivity by MGIT (93% vs. 95%, P = 0.18). Contaminated and false-positive MGIT were found more often with EMS rather than spot samples. Surprisingly, pre-treatment EMS had a higher smear grading and shorter time-to-positivity, by 1 day, than spot samples in MGIT culture (4.5 vs. 5.5 days, P spot samples in those with unfavourable outcomes, there were no differences in smear or culture results, and positive results were not detected earlier in Kaplan-Meier analyses in either EMS or spot samples. Our data do not support the hypothesis that EMS

  4. Sample size calculations based on a difference in medians for positively skewed outcomes in health care studies

    Directory of Open Access Journals (Sweden)

    Aidan G. O’Keeffe

    2017-12-01

    Full Text Available Abstract Background In healthcare research, outcomes with skewed probability distributions are common. Sample size calculations for such outcomes are typically based on estimates on a transformed scale (e.g. log which may sometimes be difficult to obtain. In contrast, estimates of median and variance on the untransformed scale are generally easier to pre-specify. The aim of this paper is to describe how to calculate a sample size for a two group comparison of interest based on median and untransformed variance estimates for log-normal outcome data. Methods A log-normal distribution for outcome data is assumed and a sample size calculation approach for a two-sample t-test that compares log-transformed outcome data is demonstrated where the change of interest is specified as difference in median values on the untransformed scale. A simulation study is used to compare the method with a non-parametric alternative (Mann-Whitney U test in a variety of scenarios and the method is applied to a real example in neurosurgery. Results The method attained a nominal power value in simulation studies and was favourable in comparison to a Mann-Whitney U test and a two-sample t-test of untransformed outcomes. In addition, the method can be adjusted and used in some situations where the outcome distribution is not strictly log-normal. Conclusions We recommend the use of this sample size calculation approach for outcome data that are expected to be positively skewed and where a two group comparison on a log-transformed scale is planned. An advantage of this method over usual calculations based on estimates on the log-transformed scale is that it allows clinical efficacy to be specified as a difference in medians and requires a variance estimate on the untransformed scale. Such estimates are often easier to obtain and more interpretable than those for log-transformed outcomes.

  5. Observed mass distribution of spontaneous fission fragments from samples of lime - an SSNTD study

    CERN Document Server

    Paul, D; Ghose, D; Sastri, R C

    1999-01-01

    SSNTD is one of the most commonly used detectors in the studies involving nuclear phenomena. The ease of registration of the presence of alpha particles and fission fragments has made it particularly suitable in studies where stable long exposures are needed to extract reliable information. Studies on the presence of alpha emitting nuclides in the environment assume importance since they are found to be carcinogenic. Lime samples from Silchar in Assam of Eastern India have shown the presence of spontaneous fission fragments besides alphas. In the present study we look at the ratio of the average mass distribution of these fission fragments, that gives us an indication of the presence of the traces of transuranic elements.

  6. Neutron beam applications - Polymer study and sample environment development for HANARO SANS instrument

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hong Doo [Kyunghee University, Seoul (Korea); Char, Kook Heon [Seoul National University, Seoul (Korea)

    2000-04-01

    A new SANS instrument will be installed in HANARO reactor near future and in parallel it is necessary to develop the sample environment facilities. One of the basic items is the equipment to control the sample temperature of cell block with auto-sample changer. It is required to develop a control software for this purpose. In addition, softwares of the aquisition and analysis for SANS instrument must be developed and supplied in order to function properly. PS/PI block copolymer research in NIST will provide the general understanding of SANS instrument and instrument-related valuable informations such as standard sample for SANS and know-hows of the instrument building. The following are the results of this research. a. Construction of sample cell block. b. Software to control the temperature and auto-sample changer. c. Acquisition of the SANS data analysis routine and its modification for HANARO SANS. d. PS/PI block copolymer research in NIST. e. Calibration data of NIST and HANARO SANS for comparison. 39 figs., 2 tabs. (Author)

  7. Sample size and saturation in PhD studies using qualitative interviews

    OpenAIRE

    Mason, Mark

    2010-01-01

    Sample-Größen sind in qualitativen Forschungsarbeiten von verschiedenen Einflüssen abhängig. Das Leitprinzip sollte jedoch immer die Sättigung, bezogen auf das jeweilige Forschungsthema sein. Diese Frage, mit der sich viele Autor/innen beschäftigt haben, wird weiter heiß diskutiert und – so einige – kaum hinreichend verstanden. Für eine eigene Untersuchung habe ich ein Sample von PhD-Studien, in denen qualitative Interviews als Erhebungsmethode genutzt wurde, aus theses.com gezogen und ...

  8. Network Sampling with Memory: A proposal for more efficient sampling from social networks

    Science.gov (United States)

    Mouw, Ted; Verdery, Ashton M.

    2013-01-01

    Techniques for sampling from networks have grown into an important area of research across several fields. For sociologists, the possibility of sampling from a network is appealing for two reasons: (1) A network sample can yield substantively interesting data about network structures and social interactions, and (2) it is useful in situations where study populations are difficult or impossible to survey with traditional sampling approaches because of the lack of a sampling frame. Despite its appeal, methodological concerns about the precision and accuracy of network-based sampling methods remain. In particular, recent research has shown that sampling from a network using a random walk based approach such as Respondent Driven Sampling (RDS) can result in high design effects (DE)—the ratio of the sampling variance to the sampling variance of simple random sampling (SRS). A high design effect means that more cases must be collected to achieve the same level of precision as SRS. In this paper we propose an alternative strategy, Network Sampling with Memory (NSM), which collects network data from respondents in order to reduce design effects and, correspondingly, the number of interviews needed to achieve a given level of statistical power. NSM combines a “List” mode, where all individuals on the revealed network list are sampled with the same cumulative probability, with a “Search” mode, which gives priority to bridge nodes connecting the current sample to unexplored parts of the network. We test the relative efficiency of NSM compared to RDS and SRS on 162 school and university networks from Add Health and Facebook that range in size from 110 to 16,278 nodes. The results show that the average design effect for NSM on these 162 networks is 1.16, which is very close to the efficiency of a simple random sample (DE=1), and 98.5% lower than the average DE we observed for RDS. PMID:24159246

  9. A Bayesian Method for Weighted Sampling

    OpenAIRE

    Lo, Albert Y.

    1993-01-01

    Bayesian statistical inference for sampling from weighted distribution models is studied. Small-sample Bayesian bootstrap clone (BBC) approximations to the posterior distribution are discussed. A second-order property for the BBC in unweighted i.i.d. sampling is given. A consequence is that BBC approximations to a posterior distribution of the mean and to the sampling distribution of the sample average, can be made asymptotically accurate by a proper choice of the random variables that genera...

  10. Sampling and examination methods used for TMI-2 samples

    International Nuclear Information System (INIS)

    Marley, A.W.; Akers, D.W.; McIsaac, C.V.

    1988-01-01

    The purpose of this paper is to summarize the sampling and examination techniques that were used in the collection and analysis of TMI-2 samples. Samples ranging from auxiliary building air to core debris were collected and analyzed. Handling of the larger samples and many of the smaller samples had to be done remotely and many standard laboratory analytical techniques were modified to accommodate the extremely high radiation fields associated with these samples. The TMI-2 samples presented unique problems with sampling and the laboratory analysis of prior molten fuel debris. 14 refs., 8 figs

  11. Study of radon exhalation and emanation rates from fly ash samples

    International Nuclear Information System (INIS)

    Raj Kumari; Jain, Ravinder; Kant, Krishan; Gupta, Nitin; Garg, Maneesha; Yadav, Mani Kant

    2013-01-01

    Fly ash, a by-product of burnt coal is technologically important material being used for manufacturing of bricks, sheets, cement, land filling etc. The increased interest in measuring radon exhalation and emanation rates in fly ash samples is due to its health hazards and environmental pollution and the same have been measured to assess the radiological impact of radon emanated from fly ash disposal sites. Samples of fly ash from different thermal power stations in northern India and National Council for Cement and Building Materials (NCB) were collected and analysed for the measurements. For the measurement, alpha sensitive LR-115 type II plastic track detectors were used. Gamma spectrometry and can technique was used for the measurements. The experimental data show that fly ash samples emanate radon in significant amount and this consequently, may result in increased radon levels in dwellings built by using fly ash bricks and excessive radiation exposure to workers residing in the surroundings of fly ash dumping sites. (author)

  12. β-trace protein as a diagnostic marker for perilymphatic fluid fistula: a prospective controlled pilot study to test a sample collection technique.

    Science.gov (United States)

    Bachmann-Harildstad, Gregor; Stenklev, Niels Christian; Myrvoll, Elin; Jablonski, Greg; Klingenberg, Olav

    2011-01-01

    The diagnosis of perilymphatic fluid (PLF) fistula is still challenging. Perilymphatic fluid fistula is one possible complication after stapedotomy or cochlear implant surgery. We have performed a prospective diagnostic pilot study to further investigate β-trace protein (β-TP) as a marker for PLF fistula. In this pilot study, we tested the sensitivity of the β-TP marker using a simple method for sample collection from the tympanic cavity. Prospective controlled diagnostic study. Two-center tertiary referral hospitals. A total of 35 adult patients undergoing ear surgery were included. Subjects were divided into 2 groups: 1) 19 patients undergoing stapedotomy were investigated for PLF fistula in samples obtained from the tympanic cavity and 2) 16 patients undergoing myringoplasty were investigated for PLF fistula in samples from the tympanic cavity. This group served as the control. Mean age +/- SD at surgery was 49.9 +/- 8.0 years in the study group and 39.69 +/- 15.47 years in the control group. β-Trace protein (prostaglandin D synthase) in tympanic cavity samples and serum samples was analyzed. The samples were collected by gradually filling the tympanic cavity with 100 to 200 μl sodium chloride and by immediately collecting a volume of 60 to 100 μl in a mucus specimen set container. The concentration of β-TP was quantified using laser nephelometry. The median β-TP in the study group was 0.8 mg/L (range, 0.05-4.5 mg/L). In the control group, the median β-TP value was 0.16 mg/L (range, 0.01-0.36 mg/L). Thirty-five percent of the values in the study group were below the highest value in the negative control group. The β-TP values of the tympanic cavity samples were significantly higher in the study group than in controls (p = 0.0001). The serum values were 0.55 +/- 0.18 and 0.53 +/- 0.11 mg/L, respectively. It may be feasible to test for PLF fistula using β-TP in samples from the tympanic cavity. Our results, however, suggest a relative low diagnostic

  13. Evaluation of HDPE water sample bottles and PVC sampler tubing used in herbicide dissipation studies.

    Science.gov (United States)

    J. B. Fischer; J. L. Michael; H. L. Gibbs

    2009-01-01

    The recovery of six herbicides (triclopyr, triclopyr ester, sulfometuron methyl, metsulfuron methyl, imazapyr, and hexazinone) was evaluated in two stream water samples, one from Weogufka Creek in the Alabama Piedmont and one from a stagnant stream in the Escambia Experimental Forest near Florida. Simulated field study conditions were...

  14. Sample Preparation and Extraction in Small Sample Volumes Suitable for Pediatric Clinical Studies: Challenges, Advances, and Experiences of a Bioanalytical HPLC-MS/MS Method Validation Using Enalapril and Enalaprilat

    Science.gov (United States)

    Burckhardt, Bjoern B.; Laeer, Stephanie

    2015-01-01

    In USA and Europe, medicines agencies force the development of child-appropriate medications and intend to increase the availability of information on the pediatric use. This asks for bioanalytical methods which are able to deal with small sample volumes as the trial-related blood lost is very restricted in children. Broadly used HPLC-MS/MS, being able to cope with small volumes, is susceptible to matrix effects. The latter restrains the precise drug quantification through, for example, causing signal suppression. Sophisticated sample preparation and purification utilizing solid-phase extraction was applied to reduce and control matrix effects. A scale-up from vacuum manifold to positive pressure manifold was conducted to meet the demands of high-throughput within a clinical setting. Faced challenges, advances, and experiences in solid-phase extraction are exemplarily presented on the basis of the bioanalytical method development and validation of low-volume samples (50 μL serum). Enalapril, enalaprilat, and benazepril served as sample drugs. The applied sample preparation and extraction successfully reduced the absolute and relative matrix effect to comply with international guidelines. Recoveries ranged from 77 to 104% for enalapril and from 93 to 118% for enalaprilat. The bioanalytical method comprising sample extraction by solid-phase extraction was fully validated according to FDA and EMA bioanalytical guidelines and was used in a Phase I study in 24 volunteers. PMID:25873972

  15. Sample Preparation and Extraction in Small Sample Volumes Suitable for Pediatric Clinical Studies: Challenges, Advances, and Experiences of a Bioanalytical HPLC-MS/MS Method Validation Using Enalapril and Enalaprilat

    Directory of Open Access Journals (Sweden)

    Bjoern B. Burckhardt

    2015-01-01

    Full Text Available In USA and Europe, medicines agencies force the development of child-appropriate medications and intend to increase the availability of information on the pediatric use. This asks for bioanalytical methods which are able to deal with small sample volumes as the trial-related blood lost is very restricted in children. Broadly used HPLC-MS/MS, being able to cope with small volumes, is susceptible to matrix effects. The latter restrains the precise drug quantification through, for example, causing signal suppression. Sophisticated sample preparation and purification utilizing solid-phase extraction was applied to reduce and control matrix effects. A scale-up from vacuum manifold to positive pressure manifold was conducted to meet the demands of high-throughput within a clinical setting. Faced challenges, advances, and experiences in solid-phase extraction are exemplarily presented on the basis of the bioanalytical method development and validation of low-volume samples (50 μL serum. Enalapril, enalaprilat, and benazepril served as sample drugs. The applied sample preparation and extraction successfully reduced the absolute and relative matrix effect to comply with international guidelines. Recoveries ranged from 77 to 104% for enalapril and from 93 to 118% for enalaprilat. The bioanalytical method comprising sample extraction by solid-phase extraction was fully validated according to FDA and EMA bioanalytical guidelines and was used in a Phase I study in 24 volunteers.

  16. Reference samples for the earth sciences

    Science.gov (United States)

    Flanagan, F.J.

    1974-01-01

    A revised list of reference samples of interest to geoscientists has been extended to include samples for the agronomist, the archaeologist and the environmentalist. In addition to the source from which standard samples may be obtained, references or pertinent notes for some samples are included. The number of rock reference samples is now almost adequate, and the variety of ore samples will soon be sufficient. There are very few samples for microprobe work. Oil shales will become more important because of the outlook for world petroleum resources. The dryland equivalent of a submarine basalt might be useful in studies of sea-floor spreading and of the geochemistry of basalts. The Na- and K-feldspars of BCS (British Chemical Standards-Bureau of Analysed Samples), NBS (National Bureau of Standards), and ANRT (Association Kationale de la Recherche Technique) could serve as trace-element standards if such data were available. Similarly, the present NBS flint and plastic clays, as well as their predecessors, might be useful for archaeological pottery studies. The International Decade for Ocean Exploration may stimulate the preparation of ocean-water standards for trace elements or pollutants and a standard for manganese nodules. ?? 1974.

  17. Sampling of illicit drugs for quantitative analysis--part II. Study of particle size and its influence on mass reduction.

    Science.gov (United States)

    Bovens, M; Csesztregi, T; Franc, A; Nagy, J; Dujourdy, L

    2014-01-01

    The basic goal in sampling for the quantitative analysis of illicit drugs is to maintain the average concentration of the drug in the material from its original seized state (the primary sample) all the way through to the analytical sample, where the effect of particle size is most critical. The size of the largest particles of different authentic illicit drug materials, in their original state and after homogenisation, using manual or mechanical procedures, was measured using a microscope with a camera attachment. The comminution methods employed included pestle and mortar (manual) and various ball and knife mills (mechanical). The drugs investigated were amphetamine, heroin, cocaine and herbal cannabis. It was shown that comminution of illicit drug materials using these techniques reduces the nominal particle size from approximately 600 μm down to between 200 and 300 μm. It was demonstrated that the choice of 1 g increments for the primary samples of powdered drugs and cannabis resin, which were used in the heterogeneity part of our study (Part I) was correct for the routine quantitative analysis of illicit seized drugs. For herbal cannabis we found that the appropriate increment size was larger. Based on the results of this study we can generally state that: An analytical sample weight of between 20 and 35 mg of an illicit powdered drug, with an assumed purity of 5% or higher, would be considered appropriate and would generate an RSDsampling in the same region as the RSDanalysis for a typical quantitative method of analysis for the most common, powdered, illicit drugs. For herbal cannabis, with an assumed purity of 1% THC (tetrahydrocannabinol) or higher, an analytical sample weight of approximately 200 mg would be appropriate. In Part III we will pull together our homogeneity studies and particle size investigations and use them to devise sampling plans and sample preparations suitable for the quantitative instrumental analysis of the most common illicit

  18. [Study on the resilience internal factors in a sample of Puerto Rican centenarians].

    Science.gov (United States)

    Rosado-Medina, José J; Rodríguez-Gómez, José R; Altieri-Ramirez, Gladys

    2012-01-01

    Old age is a stage that is usually characterized by lost at the physiological, psychological and social level that generates much distress to individuals. However, the centenaries have been identified as an example of successful aging, within other factors, because they have adequate managed skills that help them to deal with healthy normal losses. Resilience could be one of the factors that may help the Centennials to age successfully. It is necessary more studies with Puerto Rico Centennials since we lack such investigations. This study has an expo facto design; in addition we evaluate psychometrically the Symptoms Check List 90-R (SCL-90-R). The scale of Internal Resilience Factors (EFIR), a semi structured interview and the SCL-90-R were used to identify factors associated with successful aging in the centennials. In addition we explore if there exist gender differences in internal factors of resilience within the sample. 23 Centennials, 15 men and 8 women, of different parts of Puerto Rico (average age = 101. 5 years). Internal resilience factors associated with the aging process were identifying, those were: emotional stability, optimism, behavioral factor and behavioral and emotional skills component. These factors are consistent with the revised literature on positive emotions and adaptive ageing. On the other hand, no statistically significant difference was identified (p <. 05) for the internal factors of resilience on the basis of gender, a finding agreed with the revised literature. The multiple tests administered showed adequate internal consistency (EFIR: (=. 726); SCL-90-R: (=. 941). The Symptoms Check list 90-R (SCL-90-R) was valid with a Cronbach's alpha of. 941. We identified internal resilience factors that could be linked with successfully aging: those factors are encouraging the elderly population. In addition used tests showed adequate internal consistency. Limitations in relation to the size of the sample and the distribution of gender were

  19. The Center for Epidemiologic Studies Depression Scale: Factor Validity and Reliability in a French Sample of Adolescents with Intellectual Disability

    Science.gov (United States)

    Maiano, Christophe; Morin, Alexandre J. S.; Begarie, Jerome

    2011-01-01

    The purpose of this study was to test the factor validity and reliability of the Center for Epidemiologic Studies Depression Scale (CES-D) within a sample of adolescents with mild to moderate Intellectual Disability (ID). A total sample of 189 adolescents (121 boys and 68 girls), aged between 12 and 18 years old, with mild to moderate ID were…

  20. Latex Rubber Gloves as a Sampling Dosimeter Using a Novel Surrogate Sampling Device.

    Science.gov (United States)

    Sankaran, Gayatri; Lopez, Terry; Ries, Steve; Ross, John; Vega, Helen; Eastmond, David A; Krieger, Robert I

    2015-01-01

    Pesticide exposure during harvesting of crops occurs primarily to the workers' hands. When harvesters wear latex rubber gloves for personal safety and hygiene harvesting reasons, gloves accumulate pesticide residues. Hence, characterization of the gloves' properties may be useful for pesticide exposure assessments. Controlled field studies were conducted using latex rubber gloves to define the factors that influence the transfer of pesticides to the glove and that would affect their use as a residue monitoring device. A novel sampling device called the Brinkman Contact Transfer Unit (BCTU) was constructed to study the glove characteristics and residue transfer and accumulation under controlled conditions on turf. The effectiveness of latex rubber gloves as sampling dosimeters was evaluated by measuring the transferable pesticide residues as a function of time. The validation of latex rubber gloves as a residue sampling dosimeter was performed by comparing pesticide transfer and dissipation from the gloves, with the turf transferable residues sampled using the validated California (CA) Roller, a standard measure of residue transfer. The observed correlation (Pearson's correlation coefficient R(2)) between the two methods was .84 for malathion and .96 for fenpropathrin, indicating that the BCTU is a useful, reliable surrogate tool for studying available residue transfer to latex rubber gloves under experimental conditions. Perhaps more importantly, these data demonstrate that latex gloves worn by workers may be useful quantifiable matrices for measuring pesticide exposure.

  1. Prevalence study of compulsive buying in a sample with low individual monthly income

    Directory of Open Access Journals (Sweden)

    Priscilla Lourenço Leite

    2015-12-01

    Full Text Available Introduction: Compulsive buying can be characterized as an almost irresistible impulse to acquire various items. This is a current issue and the prevalence rate in the global population is around 5 to 8%. Some surveys indicate that the problem is growing in young and low-income populations. Objectives: To evaluate the prevalence of compulsive buying among people with low personal monthly incomes and analyze relationships with socio-demographic data. Methods: The Compulsive Buying Scale was administered to screen for compulsive buying and the Hospital Anxiety and Depression Scale was used to assess anxiety and depression in a sample of 56 participants. Pearson coefficients were used to test for correlations. Results: The results indicated that 44.6% presented an average family income equal to or greater than 2.76 minimum wages. It is possible that compulsive buying is not linked to the purchasing power since it was found in a low-income population. Conclusion: Despite the small sample, the results of this study are important for understanding the problem in question.

  2. Software engineering the mixed model for genome-wide association studies on large samples.

    Science.gov (United States)

    Zhang, Zhiwu; Buckler, Edward S; Casstevens, Terry M; Bradbury, Peter J

    2009-11-01

    Mixed models improve the ability to detect phenotype-genotype associations in the presence of population stratification and multiple levels of relatedness in genome-wide association studies (GWAS), but for large data sets the resource consumption becomes impractical. At the same time, the sample size and number of markers used for GWAS is increasing dramatically, resulting in greater statistical power to detect those associations. The use of mixed models with increasingly large data sets depends on the availability of software for analyzing those models. While multiple software packages implement the mixed model method, no single package provides the best combination of fast computation, ability to handle large samples, flexible modeling and ease of use. Key elements of association analysis with mixed models are reviewed, including modeling phenotype-genotype associations using mixed models, population stratification, kinship and its estimation, variance component estimation, use of best linear unbiased predictors or residuals in place of raw phenotype, improving efficiency and software-user interaction. The available software packages are evaluated, and suggestions made for future software development.

  3. Hot sample archiving. Revision 3

    International Nuclear Information System (INIS)

    McVey, C.B.

    1995-01-01

    This Engineering Study revision evaluated the alternatives to provide tank waste characterization analytical samples for a time period as recommended by the Tank Waste Remediation Systems Program. The recommendation of storing 40 ml segment samples for a period of approximately 18 months (6 months past the approval date of the Tank Characterization Report) and then composite the core segment material in 125 ml containers for a period of five years. The study considers storage at 222-S facility. It was determined that the critical storage problem was in the hot cell area. The 40 ml sample container has enough material for approximately 3 times the required amount for a complete laboratory re-analysis. The final result is that 222-S can meet the sample archive storage requirements. During the 100% capture rate the capacity is exceeded in the hot cell area, but quick, inexpensive options are available to meet the requirements

  4. Use of FTA Cards for Direct Sampling of Patients' Lesions in the Ecological Study of Cutaneous Leishmaniasis ▿

    Science.gov (United States)

    Kato, Hirotomo; Cáceres, Abraham G.; Mimori, Tatsuyuki; Ishimaru, Yuka; Sayed, Amal S. M.; Fujita, Megumi; Iwata, Hiroyuki; Uezato, Hiroshi; Velez, Lenin N.; Gomez, Eduardo A. L.; Hashiguchi, Yoshihisa

    2010-01-01

    The FTA card (Whatman) was assessed for its utility as a molecular epidemiological tool in collecting samples from patients with leishmaniasis in Peru because the card has a variety of merits; it is less invasive for patients and easy to handle for both physicians and other medical personnel for sample collection or diagnosis, in addition to its simplicity and easy countrywide and/or intercountry transportation for analysis. Samples were collected from 132 patients suspected of having leishmaniasis, and Leishmania species were successfully identified in samples from 81 patients in 15 departments of Peru by cytochrome b and mannose phosphate isomerase gene analyses. Of these, 61.7% were identified as Leishmania (Viannia) peruviana, 22.2% as L. (V.) braziliensis, 12.3% as L. (V.) guyanensis, 2.5% as L. (V.) shawi, and 1.2% as L. (V.) lainsoni. The three predominant species, L. (V.) peruviana, L. (V.) braziliensis, and L. (V.) guyanensis, were mainly found in the Andean highlands, in the tropical rainforest, and in northern and central rainforest regions, respectively. This is the first time L. (V.) shawi has been identified outside Brazil. The present study showed that the FTA card will be a useful tool for the ecological study of different forms of leishmaniasis. Furthermore, collecting samples directly from patients' lesions by using the FTA card eliminates (i) the possibility of contamination of Leishmania isolates during short- and/or long-term passages of culture in vitro in each laboratory and (ii) pain and suffering of patients from taking samples by skin biopsy. PMID:20720027

  5. Supporting Opportunities for Context-Aware Social Matching: An Experience Sampling Study

    DEFF Research Database (Denmark)

    Mayer, Julia; Barkhuus, Louise; Hiltz, Starr Roxanne

    2016-01-01

    Mobile social matching systems aim to bring people together in the physical world by recommending people nearby to each other. Going beyond simple similarity and proximity matching mechanisms, we explore a proposed framework of relational, social and personal context as predictors of match...... opportunities to map out the design space of opportunistic social matching systems. We contribute insights gained from a study combining Experience Sampling Method (ESM) with 85 students of a U.S. university and interviews with 15 of these participants. A generalized linear mixed model analysis (n=1704) showed...... that personal context (mood and busyness) as well as sociability of others nearby are the strongest predictors of contextual match interest. Participant interviews suggest operationalizing relational context using social network rarity and discoverable rarity, and incorporating skill level and learning...

  6. Removable samples for ITER—a feasibility and conceptual study

    International Nuclear Information System (INIS)

    Mertens, Ph; Neubauer, O; Philipps, V; Huber, A; Kirschner, A; Knaup, M; Borodin, D; Samm, U; Ciattaglia, S; Choi, C H; Gicquel, S; Hirai, T; Mitteau, R; Pitts, R A; Sadakov, S; Shimada, M; Veshchev, E

    2014-01-01

    The control of the radioactive inventory in the vacuum vessel of ITER is a main safety issue. Erosion of activated plasma-facing components (PFC) and co-deposition of tritiated dust on PFC and in areas below the divertor constitute the main sources of in-vessel radioactive inventory mobilizable in the case of an accident and also during venting of the vessel. To trace the dust and tritium inventory in the machine, the use of collectors in the form of removable samples was evaluated, beside other techniques, since it provides a reliable way to follow the history of the deposits and check critical areas. Four types of removable probes and two optional active diagnostics were selected out of about 30 different options. For all four probes, a conceptual design was worked out and the feasibility was checked with preliminary estimations of thermal and electromagnetic loads, as well as remote handling paths. The highest temperature estimated for the front face of all probes lies in the range 300–500 °C, which is tolerable. Installed in representative places, such removable samples may provide information about the dust and tritium distribution inside the vacuum vessel. (paper)

  7. Pharmacokinetic Studies of Chinese Medicinal Herbs Using an Automated Blood Sampling System and Liquid Chromatography-mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Yu-Tse Wu

    2012-01-01

    Full Text Available The safety of herbal products is one of the major concerns for the modernization of traditional Chinese medicine, and pharmacokinetic data of medicinal herbs guide us to design the rational use of the herbal formula. This article reviews the advantages of the automated blood sampling (ABS systems for pharmacokinetic studies. In addition, three commonly used sample preparative methods, protein precipitation, liquid-liquid extraction and solid-phase extraction, are introduced. Furthermore, the definition, causes and evaluation of matrix effects in liquid chromatography-mass spectrometry (LC/MS analysis are demonstrated. Finally, we present our previous works as practical examples of the application of ABS systems and LC/MS for the pharmacokinetic studies of Chinese medicinal herbs.

  8. Impacts of suppression on emotional responses and performance outcomes: an experience-sampling study in younger and older workers.

    Science.gov (United States)

    Yeung, Dannii Y; Fung, Helene H

    2012-11-01

    Past studies have demonstrated that older adults used less emotional suppression to regulate their emotions than did younger adults, but the effectiveness of using this emotion regulatory strategy on psychosocial well-being across age remains largely unexplored. The present study adopted an experience-sampling method to examine whether the impacts of momentary employment of emotional suppression on momentary positive and negative emotions and job performance would be different by age. Eighty-seven Chinese insurance workers, aged between 18 and 61 years, participated in a 5-day sampling study. Their affective responses at work, momentary task performance, and sales productivity were recorded. Results showed that older workers' greater use of suppression at work was associated with lower intensity of negative emotions, whereas such association was not found among younger workers. Moreover, greater use of suppression over the sampling period was significantly predictive of sales productivity of older workers, but such a positive association was not shown in younger workers. These findings reveal that the use of suppression at work may be more effective for older workers than for younger workers.

  9. Microbial environmental contamination in Italian dental clinics: A multicenter study yielding recommendations for standardized sampling methods and threshold values.

    Science.gov (United States)

    Pasquarella, Cesira; Veronesi, Licia; Napoli, Christian; Castiglia, Paolo; Liguori, Giorgio; Rizzetto, Rolando; Torre, Ida; Righi, Elena; Farruggia, Patrizia; Tesauro, Marina; Torregrossa, Maria V; Montagna, Maria T; Colucci, Maria E; Gallè, Francesca; Masia, Maria D; Strohmenger, Laura; Bergomi, Margherita; Tinteri, Carola; Panico, Manuela; Pennino, Francesca; Cannova, Lucia; Tanzi, Marialuisa

    2012-03-15

    A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and for the different sampling times. Before clinical activity, microbial water contamination in tap water reached 51,200cfu/mL (colony forming units per milliliter), and that in Dental Unit Water Systems (DUWSs) reached 872,000cfu/mL. After clinical activity, there was a significant decrease in the Total Viable Count (TVC) in tap water and in DUWSs. Pseudomonas aeruginosa was found in 2.38% (7/294) of tap water samples and in 20.06% (59/294) of DUWS samples; Legionella spp. was found in 29.96% (89/297) of tap water samples and 15.82% (47/297) of DUWS samples, with no significant difference between pre- and post-clinical activity. Microbial air contamination was highest during dental treatments, and decreased significantly at the end of the working activity (p<0.05). The microbial buildup on surfaces increased significantly during the working hours. This study provides data for the establishment of standardized sampling methods, and threshold values for contamination monitoring in dentistry. Some very critical situations have been observed which require urgent intervention. Furthermore, the study emphasizes the need for research aimed at defining effective managing strategies for dental clinics. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Evaluation the virulence of Mycobacterium bovis isolated from milk samples through histopathological study in laboratory animals.

    Science.gov (United States)

    Al-Saqur, I M; Al-Thwani, A N; Al-Attar, I M; Al-Mashhadani, M S

    2016-12-01

    Mycobacterium bovis has a broad host range, and it is the principal agent responsible for tuberculosis (TB) in bovine, domestic and wild mammals. M. bovis also infects human, causing zoonotic TB through ingestion, inhalation and, less frequently by contact with mucous membranes and broken skin. Zoonotic TB was formerly an endemic disease, usually transmitted to man by consumption of raw cow's milk. It is indistinguishable clinically or pathologically from TB caused by M. tuberculosis. The aims of this study were, to isolate and identified M. bovis from raw milk samples by different methods, and evaluate the virulence of M. bovis in laboratory animals (Rabbit). To conduct the study, ninety three cow's milk samples were collected from farms around Baghdad governorate. The decontamination of milk samples was firstly carried out, then samples were subjected to routine tests which include, direct smear for Ziehl Neelsen acid fast stain, culture, each sample was cultured on Lowenstein Jensen media with Sodium pyruvite (All cultures incubated on 37°C for 4-10weeks with continuous observation), and biochemical testes as Nitrate reduction test, Niacin paper strip test and pyrazinamidase test, were employed to diagnose and identified the bacteria. Beside molecular assay was used to confirm the identification of the isolates by Polymerase Chain Reaction (PCR) using specific primers for M. bovis. The virulence of these isolates were investigated through inoculate it in group of laboratory animals consist of 8 rabbit in addition to other group of 4 animals as control (inoculate with Phosphate Buffer Saline). The animals were scarified after 6weeks of inoculation, post- mortem examination was carried out, smears were taken from lesions, and tissue samples were collected from lymph nodes and different organs. The results revealed five isolates of M. bovis in direct smear by acid fast Ziehl-Neelsen stain, while eight isolates observed by culture, the colonies appeared with

  11. Cluster designs to assess the prevalence of acute malnutrition by lot quality assurance sampling: a validation study by computer simulation.

    Science.gov (United States)

    Olives, Casey; Pagano, Marcello; Deitchler, Megan; Hedt, Bethany L; Egge, Kari; Valadez, Joseph J

    2009-04-01

    Traditional lot quality assurance sampling (LQAS) methods require simple random sampling to guarantee valid results. However, cluster sampling has been proposed to reduce the number of random starting points. This study uses simulations to examine the classification error of two such designs, a 67x3 (67 clusters of three observations) and a 33x6 (33 clusters of six observations) sampling scheme to assess the prevalence of global acute malnutrition (GAM). Further, we explore the use of a 67x3 sequential sampling scheme for LQAS classification of GAM prevalence. Results indicate that, for independent clusters with moderate intracluster correlation for the GAM outcome, the three sampling designs maintain approximate validity for LQAS analysis. Sequential sampling can substantially reduce the average sample size that is required for data collection. The presence of intercluster correlation can impact dramatically the classification error that is associated with LQAS analysis.

  12. Comparing Microbiome Sampling Methods in a Wild Mammal: Fecal and Intestinal Samples Record Different Signals of Host Ecology, Evolution.

    Science.gov (United States)

    Ingala, Melissa R; Simmons, Nancy B; Wultsch, Claudia; Krampis, Konstantinos; Speer, Kelly A; Perkins, Susan L

    2018-01-01

    The gut microbiome is a community of host-associated symbiotic microbes that fulfills multiple key roles in host metabolism, immune function, and tissue development. Given the ability of the microbiome to impact host fitness, there is increasing interest in studying the microbiome of wild animals to better understand these communities in the context of host ecology and evolution. Human microbiome research protocols are well established, but wildlife microbiome research is still a developing field. Currently, there is no standardized set of best practices guiding the collection of microbiome samples from wildlife. Gut microflora are typically sampled either by fecal collection, rectal swabbing, or by destructively sampling the intestinal contents of the host animal. Studies rarely include more than one sampling technique and no comparison of these methods currently exists for a wild mammal. Although some studies have hypothesized that the fecal microbiome is a nested subset of the intestinal microbiome, this hypothesis has not been formally tested. To address these issues, we examined guano (feces) and distal intestinal mucosa from 19 species of free-ranging bats from Lamanai, Belize, using 16S rRNA amplicon sequencing to compare microbial communities across sample types. We found that the diversity and composition of intestine and guano samples differed substantially. In addition, we conclude that signatures of host evolution are retained by studying gut microbiomes based on mucosal tissue samples, but not fecal samples. Conversely, fecal samples retained more signal of host diet than intestinal samples. These results suggest that fecal and intestinal sampling methods are not interchangeable, and that these two microbiotas record different information about the host from which they are isolated.

  13. Comparing Microbiome Sampling Methods in a Wild Mammal: Fecal and Intestinal Samples Record Different Signals of Host Ecology, Evolution

    Directory of Open Access Journals (Sweden)

    Melissa R. Ingala

    2018-05-01

    Full Text Available The gut microbiome is a community of host-associated symbiotic microbes that fulfills multiple key roles in host metabolism, immune function, and tissue development. Given the ability of the microbiome to impact host fitness, there is increasing interest in studying the microbiome of wild animals to better understand these communities in the context of host ecology and evolution. Human microbiome research protocols are well established, but wildlife microbiome research is still a developing field. Currently, there is no standardized set of best practices guiding the collection of microbiome samples from wildlife. Gut microflora are typically sampled either by fecal collection, rectal swabbing, or by destructively sampling the intestinal contents of the host animal. Studies rarely include more than one sampling technique and no comparison of these methods currently exists for a wild mammal. Although some studies have hypothesized that the fecal microbiome is a nested subset of the intestinal microbiome, this hypothesis has not been formally tested. To address these issues, we examined guano (feces and distal intestinal mucosa from 19 species of free-ranging bats from Lamanai, Belize, using 16S rRNA amplicon sequencing to compare microbial communities across sample types. We found that the diversity and composition of intestine and guano samples differed substantially. In addition, we conclude that signatures of host evolution are retained by studying gut microbiomes based on mucosal tissue samples, but not fecal samples. Conversely, fecal samples retained more signal of host diet than intestinal samples. These results suggest that fecal and intestinal sampling methods are not interchangeable, and that these two microbiotas record different information about the host from which they are isolated.

  14. Boat sampling

    International Nuclear Information System (INIS)

    Citanovic, M.; Bezlaj, H.

    1994-01-01

    This presentation describes essential boat sampling activities: on site boat sampling process optimization and qualification; boat sampling of base material (beltline region); boat sampling of weld material (weld No. 4); problems accompanied with weld crown varieties, RPV shell inner radius tolerance, local corrosion pitting and water clarity. The equipment used for boat sampling is described too. 7 pictures

  15. A Bayesian Justification for Random Sampling in Sample Survey

    Directory of Open Access Journals (Sweden)

    Glen Meeden

    2012-07-01

    Full Text Available In the usual Bayesian approach to survey sampling the sampling design, plays a minimal role, at best. Although a close relationship between exchangeable prior distributions and simple random sampling has been noted; how to formally integrate simple random sampling into the Bayesian paradigm is not clear. Recently it has been argued that the sampling design can be thought of as part of a Bayesian's prior distribution. We will show here that under this scenario simple random sample can be given a Bayesian justification in survey sampling.

  16. Use of Sequenom sample ID Plus® SNP genotyping in identification of FFPE tumor samples.

    Directory of Open Access Journals (Sweden)

    Jessica K Miller

    Full Text Available Short tandem repeat (STR analysis, such as the AmpFlSTR® Identifiler® Plus kit, is a standard, PCR-based human genotyping method used in the field of forensics. Misidentification of cell line and tissue DNA can be costly if not detected early; therefore it is necessary to have quality control measures such as STR profiling in place. A major issue in large-scale research studies involving archival formalin-fixed paraffin embedded (FFPE tissues is that varying levels of DNA degradation can result in failure to correctly identify samples using STR genotyping. PCR amplification of STRs of several hundred base pairs is not always possible when DNA is degraded. The Sample ID Plus® panel from Sequenom allows for human DNA identification and authentication using SNP genotyping. In comparison to lengthy STR amplicons, this multiplexing PCR assay requires amplification of only 76-139 base pairs, and utilizes 47 SNPs to discriminate between individual samples. In this study, we evaluated both STR and SNP genotyping methods of sample identification, with a focus on paired FFPE tumor/normal DNA samples intended for next-generation sequencing (NGS. The ability to successfully validate the identity of FFPE samples can enable cost savings by reducing rework.

  17. Association study between the Taq1A (rs1800497 polymorphism and schizophrenia in a Brazilian sample

    Directory of Open Access Journals (Sweden)

    Quirino Cordeiro

    2014-08-01

    Full Text Available Schizophrenia is a severe psychotic disorder with recurrent relapse and functional impairment. It results from a poorly understood gene-environment interaction. The Taq1A polymorphism (located in the gene cluster NTAD is a likely candidate for schizophrenia. Its rs1800497 polymorphism was shown to be associated with DRD2 gene expression. Therefore the present work aims to investigate a possible association between schizophrenia and such polymorphism. The compared distribution of the alleles and genotypes of the studied polymorphism was investigated in a Brazilian sample of 235 patients and 834 controls. Genotypic frequencies were in Hardy-Weinberg equilibrium. There was a trend of allelic association between the Taq1A polymorphism (rs1800497 with schizophrenia in the studied sample. However no statistically differences were found between cases and controls when analyzed by gender or schizophrenia subtypes.

  18. [Epidemiological study of dental and facial asymmetries in a sample of preschool subjects].

    Science.gov (United States)

    Vitale, Marina Consuelo; Barbieri, Federica; Ricotta, Riccardo; Arpesella, Marisa; Emanuelli, Maria Teresa

    2015-01-01

    to identify the typologies of facial and dental asymmetries in a sample of children aged between 3 and 6 years and to correlate these asymmetries with possible morphological and functional situations. cross-sectional observational study. sample of 95 subjects aged between 3 and 6 years. Clinical data were collected in 10 sessions conducted during school hours in April 2013 by a doctor of Dentistry at two preschools in the city of Sanremo (Liguria Region, Northern Italy) and a kindergarten in the city of Pavia (Lombardy Region, Northern Italy). To collect the data, a weighted clinical questionnaire was used. presence and type of bad habit, type of breathing, presence and type of facial asymmetry, dental formula, presence of diastema, presence and type of occlusal asymmetries, presence and type of dental malocclusions. analysed sample consisted of 53.7% (51/95) of males and 46.3 % (44/95) females; the mean age was 4.3 ± 0.9 years. Most frequent facial asymmetry is orbits asymmetry (35%, 33/95); dental malocclusions are detected in 70%(67/95) of cases. High percentage of subjects (69.5%, 66/95) presents displacement between superior dental midline (SDM) and inferior dental midline (IDM). Several statistically significant associations are observed: in particular, asymmetry of molar ratios is linked to asymmetry of the cheekbones and displacement of the SDM; facial midline has statistical association with asymmetry of the cheekbones (p habits observed and the close correlation between: the presence of dental malocclusions and the presence of compromising habits, the presence of dental malocclusions and the presence of oral breathing.

  19. Microbiological Monitoring and Proteolytic Study of Clinical Samples From Burned and Burned Wounded Patients

    International Nuclear Information System (INIS)

    Toema, M.A.; El-Bazza, Z.E.; El-Hifnawi, H.N.; Abd-El-Hakim, E.E.

    2013-01-01

    In this study, clinical samples were collected from 100 patients admitted to Burn and Plastic Surgery Department, Faculty of Medicine, Ain Shams University, Egypt, over a period of 12 months. The proteolytic activity of 110 clinical samples taken from surfaces swabs which taken from burned and burned wounded patients with different ages and gender was examined. Screening for the proteolytic activity produced by pathogenic bacteria isolated from burned and burned wounded patients was evaluated as gram positive Bacilli and gram negative bacilli showed high proteolytic activity (46.4%) while 17.9% showed no activity. The isolated bacteria proved to have proteolytic activity were classified into high, moderate and weak. The pathogenic bacteria isolated from burned and burned wounded patients and showing proteolytic activity were identified as Pseudomonas aeruginosa, Proteus mirabilis, Proteus vulgaris, Bacillus megaterium, Bacillus cereus, Staphylococcus aureus, Escherichia coli, Klebsiella ozaeanae, Klebsiella oxytoca, Klebsiella pneumoniae and Pseudomonas fluoresces.

  20. Chorionic villus sampling and amniocentesis.

    Science.gov (United States)

    Brambati, Bruno; Tului, Lucia

    2005-04-01

    The advantages and disadvantages of common invasive methods for prenatal diagnosis are presented in light of new investigations. Several aspects of first-trimester chorionic villus sampling and mid-trimester amniocentesis remain controversial, especially fetal loss rate, feto-maternal complications, and the extension of both sampling methods to less traditional gestational ages (early amniocentesis, late chorionic villus sampling), all of which complicate genetic counseling. A recent randomized trial involving early amniocentesis and late chorionic villus sampling has confirmed previous studies, leading to the unquestionable conclusion that transabdominal chorionic villus sampling is safer. The old dispute over whether limb reduction defects are caused by chorionic villus sampling gains new vigor, with a paper suggesting that this technique has distinctive teratogenic effects. The large experience involving maternal and fetal complications following mid-trimester amniocentesis allows a better estimate of risk for comparison with chorionic villus sampling. Transabdominal chorionic villus sampling, which appears to be the gold standard sampling method for genetic investigations between 10 and 15 completed weeks, permits rapid diagnosis in high-risk cases detected by first-trimester screening of aneuploidies. Sampling efficiency and karyotyping reliability are as high as in mid-trimester amniocentesis with fewer complications, provided the operator has the required training, skill and experience.

  1. Graph sampling

    OpenAIRE

    Zhang, L.-C.; Patone, M.

    2017-01-01

    We synthesise the existing theory of graph sampling. We propose a formal definition of sampling in finite graphs, and provide a classification of potential graph parameters. We develop a general approach of Horvitz–Thompson estimation to T-stage snowball sampling, and present various reformulations of some common network sampling methods in the literature in terms of the outlined graph sampling theory.

  2. Acceptance sampling using judgmental and randomly selected samples

    Energy Technology Data Exchange (ETDEWEB)

    Sego, Landon H.; Shulman, Stanley A.; Anderson, Kevin K.; Wilson, John E.; Pulsipher, Brent A.; Sieber, W. Karl

    2010-09-01

    We present a Bayesian model for acceptance sampling where the population consists of two groups, each with different levels of risk of containing unacceptable items. Expert opinion, or judgment, may be required to distinguish between the high and low-risk groups. Hence, high-risk items are likely to be identifed (and sampled) using expert judgment, while the remaining low-risk items are sampled randomly. We focus on the situation where all observed samples must be acceptable. Consequently, the objective of the statistical inference is to quantify the probability that a large percentage of the unsampled items in the population are also acceptable. We demonstrate that traditional (frequentist) acceptance sampling and simpler Bayesian formulations of the problem are essentially special cases of the proposed model. We explore the properties of the model in detail, and discuss the conditions necessary to ensure that required samples sizes are non-decreasing function of the population size. The method is applicable to a variety of acceptance sampling problems, and, in particular, to environmental sampling where the objective is to demonstrate the safety of reoccupying a remediated facility that has been contaminated with a lethal agent.

  3. Sampling Strategies and Processing of Biobank Tissue Samples from Porcine Biomedical Models.

    Science.gov (United States)

    Blutke, Andreas; Wanke, Rüdiger

    2018-03-06

    In translational medical research, porcine models have steadily become more popular. Considering the high value of individual animals, particularly of genetically modified pig models, and the often-limited number of available animals of these models, establishment of (biobank) collections of adequately processed tissue samples suited for a broad spectrum of subsequent analyses methods, including analyses not specified at the time point of sampling, represent meaningful approaches to take full advantage of the translational value of the model. With respect to the peculiarities of porcine anatomy, comprehensive guidelines have recently been established for standardized generation of representative, high-quality samples from different porcine organs and tissues. These guidelines are essential prerequisites for the reproducibility of results and their comparability between different studies and investigators. The recording of basic data, such as organ weights and volumes, the determination of the sampling locations and of the numbers of tissue samples to be generated, as well as their orientation, size, processing and trimming directions, are relevant factors determining the generalizability and usability of the specimen for molecular, qualitative, and quantitative morphological analyses. Here, an illustrative, practical, step-by-step demonstration of the most important techniques for generation of representative, multi-purpose biobank specimen from porcine tissues is presented. The methods described here include determination of organ/tissue volumes and densities, the application of a volume-weighted systematic random sampling procedure for parenchymal organs by point-counting, determination of the extent of tissue shrinkage related to histological embedding of samples, and generation of randomly oriented samples for quantitative stereological analyses, such as isotropic uniform random (IUR) sections generated by the "Orientator" and "Isector" methods, and vertical

  4. Comparison of sampling designs for estimating deforestation from landsat TM and MODIS imagery: a case study in Mato Grosso, Brazil.

    Science.gov (United States)

    Zhu, Shanyou; Zhang, Hailong; Liu, Ronggao; Cao, Yun; Zhang, Guixin

    2014-01-01

    Sampling designs are commonly used to estimate deforestation over large areas, but comparisons between different sampling strategies are required. Using PRODES deforestation data as a reference, deforestation in the state of Mato Grosso in Brazil from 2005 to 2006 is evaluated using Landsat imagery and a nearly synchronous MODIS dataset. The MODIS-derived deforestation is used to assist in sampling and extrapolation. Three sampling designs are compared according to the estimated deforestation of the entire study area based on simple extrapolation and linear regression models. The results show that stratified sampling for strata construction and sample allocation using the MODIS-derived deforestation hotspots provided more precise estimations than simple random and systematic sampling. Moreover, the relationship between the MODIS-derived and TM-derived deforestation provides a precise estimate of the total deforestation area as well as the distribution of deforestation in each block.

  5. Levels of heavy metals and essential minerals in hair samples of children with autism in Oman: a case-control study.

    Science.gov (United States)

    Al-Farsi, Yahya M; Waly, Mostafa I; Al-Sharbati, Marwan M; Al-Shafaee, Mohammed A; Al-Farsi, Omar A; Al-Khaduri, Maha M; Gupta, Ishita; Ouhtit, Allal; Al-Adawi, Samir; Al-Said, Mona F; Deth, Richard C

    2013-02-01

    Toxic levels of heavy metals and low levels of essential minerals have been suggested to play a critical role in the pathogenesis of autism spectrum disorders (ASD). This study documents the levels of heavy metals and essential minerals in hair samples of children with ASD in Muscat, the urbanized capital of Oman, Muscat. The study included 27 children with ASD and 27 matched non-ASD controls. Parental interviews were held and dietary intake questionnaires completed in conjunction with the collection of hair samples. Analysis of heavy metals and essential minerals was carried out by inductively coupled plasma mass spectrometry. Chi-square analysis and non-parametric Fisher's exact tests were used to assess statistical significance. Children with ASD had significantly higher levels of all 11 analyzed heavy metals in their hair samples (P minerals sulfur, sodium, magnesium, potassium, zinc, and iron, but lower levels of calcium and copper in their hair samples. This study corroborates data from previous studies in different parts of the world indicating the presence of elevated levels of heavy metals and selective depletion of essential minerals in the hair of children with ASD.

  6. Hurlbert Index of Sexual Assertiveness: a study of psychometric properties in a Spanish sample.

    Science.gov (United States)

    Santos-Iglesias, Pablo; Sierra, Juan Carlos

    2010-08-01

    The study analyzed psychometric properties of a Spanish version of the Hurlbert Index of Sexual Assertiveness in a Spanish sample of 400 men and 453 women who had had a partner for the last 6 mo. or longer at the time of the study. Exploratory and confirmatory factor analyses suggested a two-factor solution with the factors Initiation and No shyness/Refusal. Internal consistency values for total scores were .87 and .83 for the factors, respectively. Convergent validity tests were also satisfactory. It is therefore reasonable to conclude that the Spanish version of the scale has appropriate psychometric properties.

  7. How iSamples (Internet of Samples in the Earth Sciences) Improves Sample and Data Stewardship in the Next Generation of Geoscientists

    Science.gov (United States)

    Hallett, B. W.; Dere, A. L. D.; Lehnert, K.; Carter, M.

    2016-12-01

    Vast numbers of physical samples are routinely collected by geoscientists to probe key scientific questions related to global climate change, biogeochemical cycles, magmatic processes, mantle dynamics, etc. Despite their value as irreplaceable records of nature the majority of these samples remain undiscoverable by the broader scientific community because they lack a digital presence or are not well-documented enough to facilitate their discovery and reuse for future scientific and educational use. The NSF EarthCube iSamples Research Coordination Network seeks to develop a unified approach across all Earth Science disciplines for the registration, description, identification, and citation of physical specimens in order to take advantage of the new opportunities that cyberinfrastructure offers. Even as consensus around best practices begins to emerge, such as the use of the International Geo Sample Number (IGSN), more work is needed to communicate these practices to investigators to encourage widespread adoption. Recognizing the importance of students and early career scientists in particular to transforming data and sample management practices, the iSamples Education and Training Working Group is developing training modules for sample collection, documentation, and management workflows. These training materials are made available to educators/research supervisors online at http://earthcube.org/group/isamples and can be modularized for supervisors to create a customized research workflow. This study details the design and development of several sample management tutorials, created by early career scientists and documented in collaboration with undergraduate research students in field and lab settings. Modules under development focus on rock outcrops, rock cores, soil cores, and coral samples, with an emphasis on sample management throughout the collection, analysis and archiving process. We invite others to share their sample management/registration workflows and to

  8. Using Environmental Variables for Studying of the Quality of Sampling in Soil Mapping

    OpenAIRE

    A. Jafari; Norair Toomanian; R. Taghizadeh Mehrjerdi

    2016-01-01

    Introduction: Methods of soil survey are generally empirical and based on the mental development of the surveyor, correlating soil with underlying geology, landforms, vegetation and air-photo interpretation. Since there are no statistical criteria for traditional soil sampling; this may lead to bias in the areas being sampled. In digital soil mapping, soil samples may be used to elaborate quantitative relationships or models between soil attributes and soil covariates. Because the relationshi...

  9. Optimal sampling schemes applied in geology

    CSIR Research Space (South Africa)

    Debba, Pravesh

    2010-05-01

    Full Text Available Methodology 6 Results 7 Background and Research Question for Study 2 8 Study Area and Data 9 Methodology 10 Results 11 Conclusions Debba (CSIR) Optimal Sampling Schemes applied in Geology UP 2010 2 / 47 Outline 1 Introduction to hyperspectral remote... sensing 2 Objective of Study 1 3 Study Area 4 Data used 5 Methodology 6 Results 7 Background and Research Question for Study 2 8 Study Area and Data 9 Methodology 10 Results 11 Conclusions Debba (CSIR) Optimal Sampling Schemes applied in Geology...

  10. Design-based estimators for snowball sampling

    OpenAIRE

    Shafie, Termeh

    2010-01-01

    Snowball sampling, where existing study subjects recruit further subjects from amongtheir acquaintances, is a popular approach when sampling from hidden populations.Since people with many in-links are more likely to be selected, there will be a selectionbias in the samples obtained. In order to eliminate this bias, the sample data must beweighted. However, the exact selection probabilities are unknown for snowball samplesand need to be approximated in an appropriate way. This paper proposes d...

  11. Study on the determination of palladium in biological samples by the method of neutron activation analysis

    International Nuclear Information System (INIS)

    Cavalcante, Cassio Queiroz

    2007-01-01

    Palladium is one of platinum group elements present in the nature at very low concentrations. However with the use of this element in the automobile catalyzers Pd became a new pollutant. Besides, Pd has been studied in the preparation of new antitumour drugs. Consequently, there is a need to determine Pd concentrations in biological and environmental samples. This study presents palladium results obtained in the analysis of biological samples and reference materials using instrumental thermal and epithermal neutron activation analysis (INAA and ENAA). The solvent extraction and solid phase extraction separation methods were also applied before ENAA. The samples analyzed in this study were, reference material BCR 723 - Palladium, Platinum and Rhodium in road dust, CCQM-P63 automotive catalyst material of the Proficiency Test and bovine tissue samples containing palladium prepared in the laboratory. Samples and palladium synthetic standard were irradiated at the IEA-R1 nuclear research reactor under thermal neutron flux of about 4 x 10 12 n cm-2 s-1, during a period of 4 and 16 h for INAA and ENAA, respectively. The induced gamma activity of 109 Pd to the sample and standard was measured using a hyper pure Ge detector coupled to a gamma ray spectrometer. The palladium concentration was calculated by comparative method. The gamma ray energy of 109 Pd radioisotope measured was of 88.0 keV, located in a spectrum region of low energy where occurs the interference of X rays, 'Bremsstrahlung' radiations, as well as Compton effect of 24 Na. The pre-separation of palladium from interfering elements by solvent extraction was performed using dimethylglyoxime complexant and chloroform as diluent. In the case of the pre separation procedure using solid reversed phase column, the palladium was retained using N,N-diethyl-N'-benzoyl thiourea complexant and eluted using ethanol. Aliquots of the resulting solutions from the pre-separations, free of interfering elements, were

  12. Sample Curation in Support of the OSIRIS-REx Asteroid Sample Return Mission

    Science.gov (United States)

    Righter, Kevin; Nakamura-Messenger, Keiko

    2017-01-01

    The OSIRIS-REx asteroid sample return mission launched to asteroid Bennu Sept. 8, 2016. The spacecraft will arrive at Bennu in late 2019, orbit and map the asteroid, and perform a touch and go (TAG) sampling maneuver in July 2020. After sample is stowed and confirmed the spacecraft will return to Earth, and the sample return capsule (SRC) will land in Utah in September 2023. Samples will be recovered from Utah [2] and then transported and stored in a new sample cleanroom at NASA Johnson Space Center in Houston [3]. The materials curated for the mission are described here. a) Materials Archive and Witness Plate Collection: The SRC and TAGSAM were built between March 2014 and Summer of 2015, and instruments (OTES,OVIRS, OLA, OCAMS, REXIS) were integrated from Summer 2015 until May 2016. A total of 395 items were received for the materials archive at NASA-JSC, with archiving finishing 30 days after launch (with the final archived items being related to launch operations)[4]. The materials fall into several general categories including metals (stainless steel, aluminum, titanium alloys, brass and BeCu alloy), epoxies, paints, polymers, lubricants, non-volatile-residue samples (NVR), sapphire, and various miscellaneous materials. All through the ATLO process (from March 2015 until late August 2016) contamination knowledge witness plates (Si wafer and Al foil) were deployed in the various cleanrooms in Denver and KSC to provide an additional record of particle counts and volatiles that is archived for current and future scientific studies. These plates were deployed in roughly monthly increments with each unit containing 4 Si wafers and 4 Al foils. We archived 128 individual witness plates (64 Si wafers and 64 Al foils); one of each witness plate (Si and Al) was analyzed immediately by the science team after archiving, while the remaining 3 of each are archived indefinitely. Information about each material archived is stored in an extensive database at NASA-JSC, and key

  13. Sampling a guide for internal auditors

    CERN Document Server

    Apostolou, Barbara

    2004-01-01

    While it is possible to examine 100 percent of an audit customer's data, the time and cost associated with such a study are often prohibitive. To obtain sufficient, reliable, and relevant information with a limited data set, sampling is an efficient and effective tool. It can help you evaluate the customer's assertions, as well as reach audit conclusions and provide reasonable assurance to your organization. This handbook will help you understand sampling. It also serves as a guide for auditors and students preparing for certification. Topics include: An overview of sampling. Statistical and nonstatistical sampling issues. Sampling selection methods and risks. The pros and cons of popular sampling plans.

  14. A comprehensive comparison of perpendicular distance sampling methods for sampling downed coarse woody debris

    Science.gov (United States)

    Jeffrey H. Gove; Mark J. Ducey; Harry T. Valentine; Michael S. Williams

    2013-01-01

    Many new methods for sampling down coarse woody debris have been proposed in the last dozen or so years. One of the most promising in terms of field application, perpendicular distance sampling (PDS), has several variants that have been progressively introduced in the literature. In this study, we provide an overview of the different PDS variants and comprehensive...

  15. Prompt Gamma Ray Analysis of Soil Samples

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A.; Khiari, F.Z.; Haseeb, S.M.A.; Hussein, Tanvir; Khateeb-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Isab, A.H. [Department of Chemistry, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2015-07-01

    Neutron moderation effects were measured in bulk soil samples through prompt gamma ray measurements from water and benzene contaminated soil samples using 14 MeV neutron inelastic scattering. The prompt gamma rays were measured using a cylindrical 76 mm x 76 mm (diameter x height) LaBr{sub 3}:Ce detector. Since neutron moderation effects strongly depend upon hydrogen concentration of the sample, for comparison purposes, moderation effects were studied from samples containing different hydrogen concentrations. The soil samples with different hydrogen concentration were prepared by mixing soil with water as well as benzene in different weight proportions. Then, the effects of increasing water and benzene concentrations on the yields of hydrogen, carbon and silicon prompt gamma rays were measured. Moderation effects are more pronounced in soil samples mixed with water as compared to those from soil samples mixed with benzene. This is due to the fact that benzene contaminated soil samples have about 30% less hydrogen concentration by weight than the water contaminated soil samples. Results of the study will be presented. (authors)

  16. Planetary Sample Caching System Design Options

    Science.gov (United States)

    Collins, Curtis; Younse, Paulo; Backes, Paul

    2009-01-01

    Potential Mars Sample Return missions would aspire to collect small core and regolith samples using a rover with a sample acquisition tool and sample caching system. Samples would need to be stored in individual sealed tubes in a canister that could be transfered to a Mars ascent vehicle and returned to Earth. A sample handling, encapsulation and containerization system (SHEC) has been developed as part of an integrated system for acquiring and storing core samples for application to future potential MSR and other potential sample return missions. Requirements and design options for the SHEC system were studied and a recommended design concept developed. Two families of solutions were explored: 1)transfer of a raw sample from the tool to the SHEC subsystem and 2)transfer of a tube containing the sample to the SHEC subsystem. The recommended design utilizes sample tool bit change out as the mechanism for transferring tubes to and samples in tubes from the tool. The SHEC subsystem design, called the Bit Changeout Caching(BiCC) design, is intended for operations on a MER class rover.

  17. The role of NAA in the environmental studies. Quantitative determination of heavy metals pollutant on environmental samples

    International Nuclear Information System (INIS)

    Sutisna; Yusuf, Saeful; Fisli, Adel; Rukihati; Wardhani, Sri; Th Rina M

    2003-01-01

    The neutron activation analysis technique was applied in the elemental analysis of environmental samples to solve an environmental pollution problem. We focused our study in the analysis of heavy metal which has potentially become a pollutant. The environmental samples analyzed were some water, sediment and an air particulate matter. The tap water sample was collected from five samplings points located at region of Serpong and Muria. Meanwhile the river water samples were taken from five samplings points of Ciliwung River. Eight samplings points of Cisadane river estuary located at Tanjung Burung were selected to collect sediment samples. Air particulate samples were collected from Jakarta Metropolitan and Serpong using high volume air sampler. Trace elements analyses of water samples were done using a combination of INAA and pre-concentration stage prior irradiation. All samples were irradiated at GA. Siwabessy reactor located at Serpong using a thermal neutron flux of about 10 12 n.cm -2 .sec -1 . After cooling time, the samples irradiated were counted by a high resolution HPGe detector coupled to a multichannel analyzer. The quantitative analyses have been done using a comparative method to a fresh laboratory standard and we used some standard references materials to validate our analytical result. The obtained result from the tap water analysis show that the elements of As, Cr, Co, Cd, Mn, Sb and Zn could be determine quantitatively and they have a concentration range from about 0.02 μg/L to 103.9 μg/L. The analysis result of Ciliwung river water samples show that elements of Ag, As, Co, Cu, Fe, Hg, Mn, V and Zn are present in the range of 2.4 μg/L to about 1365.8 μg/L. Meanwhile some important elements were obtained in the sediments samples taken from Cisadane River estuary such as Ce (40.4 - 63.6 mg/kg), Co (15.2 - 40.2 mg/kg), Cr (21.6 - 57.8 mg/kg), Eu (1.2 - 1.8 mg/kg), Fe (7.0 - 16.8 mg/kg), Mn (887 - 1810 mg/kg) and V (160 - 558 mg/kg). Finally the

  18. 40 CFR 1065.245 - Sample flow meter for batch sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Sample flow meter for batch sampling... Sample flow meter for batch sampling. (a) Application. Use a sample flow meter to determine sample flow... difference between a diluted exhaust sample flow meter and a dilution air meter to calculate raw exhaust flow...

  19. Adrenal hormones before and after venography during adrenal venous sampling: a self-controlled study.

    Science.gov (United States)

    Koike, Yuya; Matsui, Seishi; Omura, Masao; Makita, Kohzoh; Obara, Alfonso W D; Moriya, Nobukazu; Nishikawa, Tetsuo

    2017-03-01

    A stress reaction involving increased adrenal hormone release occurs when starting adrenal venous sampling (AVS). The purpose of the present study was to investigate the effect of single shot venography on adrenal hormone production during AVS. This was a prospective self-controlled study. We enrolled 54 consecutive patients (21 men, 33 women; mean age 52 ± 11 years) with primary aldosteronism who underwent AVS from May 2014 to February 2015. Under non-stimulated conditions, blood samples were obtained from a common trunk of the left adrenal vein before and after single shot venography. The initial plasma aldosterone and cortisol concentration (PAC and PCC) were compared with those measured after venography for each patient. PAC and PCC were slightly but significantly decreased between before and after venography (after log transformation 2.12 ± 0.73 vs 2.07 ± 0.72, P = 0.00066, 1.89 ± 0.52 vs 1.83 ± 0.53, P = 0.00031, respectively). During non-stimulated left AVS, adrenal hormone secretion was slightly but significantly decreased after venography, similar to the normal time-related stress reaction. Venography did not increase the adrenal hormone secretion.

  20. Balanced sampling

    NARCIS (Netherlands)

    Brus, D.J.

    2015-01-01

    In balanced sampling a linear relation between the soil property of interest and one or more covariates with known means is exploited in selecting the sampling locations. Recent developments make this sampling design attractive for statistical soil surveys. This paper introduces balanced sampling

  1. GY SAMPLING THEORY IN ENVIRONMENTAL STUDIES 2: SUBSAMPLING ERROR MEASUREMENTS

    Science.gov (United States)

    Sampling can be a significant source of error in the measurement process. The characterization and cleanup of hazardous waste sites require data that meet site-specific levels of acceptable quality if scientifically supportable decisions are to be made. In support of this effort,...

  2. Sampling in Developmental Science: Situations, Shortcomings, Solutions, and Standards.

    Science.gov (United States)

    Bornstein, Marc H; Jager, Justin; Putnick, Diane L

    2013-12-01

    Sampling is a key feature of every study in developmental science. Although sampling has far-reaching implications, too little attention is paid to sampling. Here, we describe, discuss, and evaluate four prominent sampling strategies in developmental science: population-based probability sampling, convenience sampling, quota sampling, and homogeneous sampling. We then judge these sampling strategies by five criteria: whether they yield representative and generalizable estimates of a study's target population, whether they yield representative and generalizable estimates of subsamples within a study's target population, the recruitment efforts and costs they entail, whether they yield sufficient power to detect subsample differences, and whether they introduce "noise" related to variation in subsamples and whether that "noise" can be accounted for statistically. We use sample composition of gender, ethnicity, and socioeconomic status to illustrate and assess the four sampling strategies. Finally, we tally the use of the four sampling strategies in five prominent developmental science journals and make recommendations about best practices for sample selection and reporting.

  3. Detecting evidence for CO2 fertilization from tree ring studies: The potential role of sampling biases

    NARCIS (Netherlands)

    Brienen, R.J.W.; Gloor, E.; Zuidema, P.A.

    2012-01-01

    Tree ring analysis allows reconstructing historical growth rates over long periods. Several studies have reported an increasing trend in ring widths, often attributed to growth stimulation by increasing atmospheric CO2 concentration. However, these trends may also have been caused by sampling

  4. Ensemble Sampling

    OpenAIRE

    Lu, Xiuyuan; Van Roy, Benjamin

    2017-01-01

    Thompson sampling has emerged as an effective heuristic for a broad range of online decision problems. In its basic form, the algorithm requires computing and sampling from a posterior distribution over models, which is tractable only for simple special cases. This paper develops ensemble sampling, which aims to approximate Thompson sampling while maintaining tractability even in the face of complex models such as neural networks. Ensemble sampling dramatically expands on the range of applica...

  5. Determination of mineral abundances in samples from the exploratory studies facility using x-ray diffraction

    International Nuclear Information System (INIS)

    Roberts, S.; Viani, R.

    1998-01-01

    Tuff samples collected from the Exploratory Studies Facility (ESF) were X-rayed to estimate relative mineral abundances. X-ray analysis was performed on sub-samples of specimens collected from both the Single Heater Test (SHT) and Drift Scale Heater Test (DST) that were used for thermomechanical measurements, as well as samples collected from cores retrieved from boreholes in the Drift Scale Test Area. The abundance of minerals that could affect the behavior of the host rock at repository relevant temperatures is of particular interest. These minerals include crystobalite, which undergoes a phase transition and volume change at elevated temperature (-250 'C), and smectite and clinoptilolite that can dehydrate at elevated temperature with accompanying volume reduction. In addition, the spatial distribution of SiO, polymorphs and secondary minerals may provide evidence for deducing past fluid pathways. The mineral abundances tabulated here include data reported previously in three milestone reports (Roberts and Viani, 1997a,b; Viani and Roberts, 1996) but re-analyzed (see below), as well as previously unreported data. Previous X-ray diffraction analyses of samples from the ESF (Roberts and Viani, 1997a; Viani and Roberts, 1996) utilized the matrix flushing method of Chung (1974) and an internal intensity standard (corundum) to quantify the abundances of the phases present. Although the method is adequate for obtaining relative abundances, its accuracy and precision is limited by the inherent differences between the external standards used to compute the reference intensity ratio and the mineral phases in the sample. In a subsequent report (Roberts and Viani, 1997b) mineral abundances were obtained using the Rietveld method of whole X-ray pattern fitting (Snyder and Bish, 1989; Young, 1993). The Rietveld technique has the potential to be both more accurate and more precise for estimating mineral abundances (Snyder and Bish, 1989)

  6. Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study.

    Science.gov (United States)

    De Kesel, Pieter M M; Lambert, Willy E; Stove, Christophe P

    2015-06-30

    Volumetric absorptive microsampling (VAMS) is a novel sampling technique that allows the straightforward collection of an accurate volume of blood (approximately 10μL) from a drop or pool of blood by dipping an absorbent polymeric tip into it. The resulting blood microsample is dried and analyzed as a whole. The aim of this study was to evaluate the potential of VAMS to overcome the hematocrit bias, an important issue in the analysis of dried blood microsamples. An LC-MS/MS method for analysis of the model compounds caffeine and paraxanthine in VAMS samples was fully validated and fulfilled all pre-established criteria. In conjunction with previously validated procedures for dried blood spots (DBS) and blood, this allowed us to set up a meticulous comparative study in which both compounds were determined in over 80 corresponding VAMS, DBS and liquid whole blood samples. These originated from authentic human patient samples, covering a wide hematocrit range (0.21-0.50). By calculating the differences with reference whole blood concentrations, we found that analyte concentrations in VAMS samples were not affected by a bias that changed over the evaluated hematocrit range, in contrast to DBS results. However, VAMS concentrations tend to overestimate whole blood concentrations, as a consistent positive bias was observed. A different behavior of VAMS samples prepared from incurred and spiked blood, combined with a somewhat reduced recovery of caffeine and paraxanthine from VAMS tips at high hematocrit values, an effect that was not observed for DBS using a very similar extraction procedure, was found to be at the basis of the observed VAMS-whole blood deviations. Based on this study, being the first in which the validity and robustness of VAMS is evaluated by analyzing incurred human samples, it can be concluded that VAMS effectively assists in eliminating the effect of hematocrit. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Seasonal rationalization of river water quality sampling locations: a comparative study of the modified Sanders and multivariate statistical approaches.

    Science.gov (United States)

    Varekar, Vikas; Karmakar, Subhankar; Jha, Ramakar

    2016-02-01

    The design of surface water quality sampling location is a crucial decision-making process for rationalization of monitoring network. The quantity, quality, and types of available dataset (watershed characteristics and water quality data) may affect the selection of appropriate design methodology. The modified Sanders approach and multivariate statistical techniques [particularly factor analysis (FA)/principal component analysis (PCA)] are well-accepted and widely used techniques for design of sampling locations. However, their performance may vary significantly with quantity, quality, and types of available dataset. In this paper, an attempt has been made to evaluate performance of these techniques by accounting the effect of seasonal variation, under a situation of limited water quality data but extensive watershed characteristics information, as continuous and consistent river water quality data is usually difficult to obtain, whereas watershed information may be made available through application of geospatial techniques. A case study of Kali River, Western Uttar Pradesh, India, is selected for the analysis. The monitoring was carried out at 16 sampling locations. The discrete and diffuse pollution loads at different sampling sites were estimated and accounted using modified Sanders approach, whereas the monitored physical and chemical water quality parameters were utilized as inputs for FA/PCA. The designed optimum number of sampling locations for monsoon and non-monsoon seasons by modified Sanders approach are eight and seven while that for FA/PCA are eleven and nine, respectively. Less variation in the number and locations of designed sampling sites were obtained by both techniques, which shows stability of results. A geospatial analysis has also been carried out to check the significance of designed sampling location with respect to river basin characteristics and land use of the study area. Both methods are equally efficient; however, modified Sanders

  8. SWOT ANALYSIS ON SAMPLING METHOD

    Directory of Open Access Journals (Sweden)

    CHIS ANCA OANA

    2014-07-01

    Full Text Available Audit sampling involves the application of audit procedures to less than 100% of items within an account balance or class of transactions. Our article aims to study audit sampling in audit of financial statements. As an audit technique largely used, in both its statistical and nonstatistical form, the method is very important for auditors. It should be applied correctly for a fair view of financial statements, to satisfy the needs of all financial users. In order to be applied correctly the method must be understood by all its users and mainly by auditors. Otherwise the risk of not applying it correctly would cause loose of reputation and discredit, litigations and even prison. Since there is not a unitary practice and methodology for applying the technique, the risk of incorrectly applying it is pretty high. The SWOT analysis is a technique used that shows the advantages, disadvantages, threats and opportunities. We applied SWOT analysis in studying the sampling method, from the perspective of three players: the audit company, the audited entity and users of financial statements. The study shows that by applying the sampling method the audit company and the audited entity both save time, effort and money. The disadvantages of the method are difficulty in applying and understanding its insight. Being largely used as an audit method and being a factor of a correct audit opinion, the sampling method’s advantages, disadvantages, threats and opportunities must be understood by auditors.

  9. Modern survey sampling

    CERN Document Server

    Chaudhuri, Arijit

    2014-01-01

    Exposure to SamplingAbstract Introduction Concepts of Population, Sample, and SamplingInitial RamificationsAbstract Introduction Sampling Design, Sampling SchemeRandom Numbers and Their Uses in Simple RandomSampling (SRS)Drawing Simple Random Samples with and withoutReplacementEstimation of Mean, Total, Ratio of Totals/Means:Variance and Variance EstimationDetermination of Sample SizesA.2 Appendix to Chapter 2 A.More on Equal Probability Sampling A.Horvitz-Thompson EstimatorA.SufficiencyA.LikelihoodA.Non-Existence Theorem More Intricacies Abstract Introduction Unequal Probability Sampling StrategiesPPS Sampling Exploring Improved WaysAbstract Introduction Stratified Sampling Cluster SamplingMulti-Stage SamplingMulti-Phase Sampling: Ratio and RegressionEstimationviiviii ContentsControlled SamplingModeling Introduction Super-Population ModelingPrediction Approach Model-Assisted Approach Bayesian Methods Spatial SmoothingSampling on Successive Occasions: Panel Rotation Non-Response and Not-at-Homes Weighting Adj...

  10. Learning to reason from samples

    NARCIS (Netherlands)

    Ben-Zvi, Dani; Bakker, Arthur; Makar, Katie

    2015-01-01

    The goal of this article is to introduce the topic of learning to reason from samples, which is the focus of this special issue of Educational Studies in Mathematics on statistical reasoning. Samples are data sets, taken from some wider universe (e.g., a population or a process) using a particular

  11. Comparison of Sampling Designs for Estimating Deforestation from Landsat TM and MODIS Imagery: A Case Study in Mato Grosso, Brazil

    Directory of Open Access Journals (Sweden)

    Shanyou Zhu

    2014-01-01

    Full Text Available Sampling designs are commonly used to estimate deforestation over large areas, but comparisons between different sampling strategies are required. Using PRODES deforestation data as a reference, deforestation in the state of Mato Grosso in Brazil from 2005 to 2006 is evaluated using Landsat imagery and a nearly synchronous MODIS dataset. The MODIS-derived deforestation is used to assist in sampling and extrapolation. Three sampling designs are compared according to the estimated deforestation of the entire study area based on simple extrapolation and linear regression models. The results show that stratified sampling for strata construction and sample allocation using the MODIS-derived deforestation hotspots provided more precise estimations than simple random and systematic sampling. Moreover, the relationship between the MODIS-derived and TM-derived deforestation provides a precise estimate of the total deforestation area as well as the distribution of deforestation in each block.

  12. Factorial composition of the Aggression Questionnaire: a multi-sample study in Greek adults.

    Science.gov (United States)

    Vitoratou, Silia; Ntzoufras, Ioannis; Smyrnis, Nikolaos; Stefanis, Nicholas C

    2009-06-30

    The primary aim of the current article was the evaluation of the factorial composition of the Aggression Questionnaire (AQ(29)) in the Greek population. The translated questionnaire was administered to the following three heterogeneous adult samples: a general population sample from Athens, a sample of young male conscripts and a sample of individuals facing problems related to substance use. Factor analysis highlighted a structure similar to the one proposed by Buss and Perry [Buss, A.F., Perry, M., 1992. The Aggression Questionnaire. Journal of Personality and Social Psychology 63, 452-459]. However, the refined 12-item version of Bryant and Smith [Bryant, F.B., Smith, B.D., 2001. Refining the architecture of aggression: a measurement model for the Buss-Perry Aggression Questionnaire. Journal of Research in Personality 35, 138-167] provided a better fit to our data. Therefore, the refined model was implemented in further analysis. Multiple group confirmatory factor analysis was applied in order to assess the variability of the 12-item AQ across gender and samples. The percentage of factor loading invariance between males and females and across the three samples defined above was high (higher than 75%). The reliability (internal consistency) of the scale was satisfactory in all cases. Content validity of the 12-item AQ was confirmed by comparison with the Symptom Check-List 90 Revised.

  13. Preparation of samples for leaf architecture studies, a method for mounting cleared leaves1

    Science.gov (United States)

    Vasco, Alejandra; Thadeo, Marcela; Conover, Margaret; Daly, Douglas C.

    2014-01-01

    • Premise of the study: Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. • Methods and Results: Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. • Conclusions: The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration. PMID:25225627

  14. Does body satisfaction influence self-esteem in adolescents' daily lives? An experience sampling study.

    Science.gov (United States)

    Fuller-Tyszkiewicz, Matthew; McCabe, Marita; Skouteris, Helen; Richardson, Ben; Nihill, Kristy; Watson, Brittany; Solomon, Daniel

    2015-12-01

    This study examined, within the context of the Contingencies of Self-Worth model, state-based associations between self-esteem and body satisfaction using the experience sampling method. One hundred and forty-four adolescent girls (mean age = 14.28 years) completed up to 6 assessments per day for one week using Palm Digital Assistants, in addition to baseline measures of trait body satisfaction and self-esteem. Results showed considerable variation in both state-based constructs within days, and evidence of effects of body satisfaction on self-esteem, but not vice versa. Although these state-based associations were small in size and weakened as the time lag between assessments increased for the sample as a whole, individual differences in the magnitude of these effects were observed and predicted by trait self-esteem and body satisfaction. Collectively, these findings offer support for key tenets of the Contingencies of Self-Worth model. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  15. Two sampling techniques for game meat

    OpenAIRE

    van der Merwe, Maretha; Jooste, Piet J.; Hoffman, Louw C.; Calitz, Frikkie J.

    2013-01-01

    A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g) and square centimetres (cm2) for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12) that statistically proved the two measuring units correlated. The two sampling...

  16. An integrated rock magnetic and EPR study in soil samples from a hydrocarbon prospective area

    Science.gov (United States)

    González, F.; Aldana, M.; Costanzo-Álvarez, V.; Díaz, M.; Romero, I.

    Magnetic susceptibility (MS) and organic matter free radical concentration (OMFRC) determined by electron paramagnetic resonance, have been measured in soil samples (≈1.5 m depth) from an oil prospective area located at the southern flank of the Venezuelan Andean Range. S-ratios close to 1, as well as high temperature susceptibility analyses, reveal magnetite as the chief magnetic phase in most of these samples. Ethane concentrations, MS and OMFRC normalized data have been plotted against the relative position of 22 sampling sites sequentially arranged from north to south. Although there is not a linear correlation between MS and OMFRC data, these two profiles seem to vary in like fashion. A MS and OMFRC southern anomaly coincides with the zone of highest ethane concentration that overlies a “Cretaceous kitchen”. OMFRC highs could be linked to the degradation or alteration of organic matter, the possible result of hydrocarbon gas leakage, whose surface expression is the stressed fern observed by remote sensing studies previously performed in the area. Ethane anomalies are associated to this seepage that also produces changes in the magnetic mineralogies detected as MS positive anomalies.

  17. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  18. Air sampling in the workplace

    International Nuclear Information System (INIS)

    Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R.; Wiblin, C.M.; McGuire, S.A.

    1993-09-01

    This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC's Regulatory Guide 8.25, Revision 1, ''Air sampling in the Workplace.'' That guide addresses air sampling to meet the requirements in NRC's regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed

  19. Accounting for Diversity in Suicide Research: Sampling and Sample Reporting Practices in the United States.

    Science.gov (United States)

    Cha, Christine B; Tezanos, Katherine M; Peros, Olivia M; Ng, Mei Yi; Ribeiro, Jessica D; Nock, Matthew K; Franklin, Joseph C

    2018-04-01

    Research on suicidal thoughts and behaviors (STB) has identified many risk factors, but whether these findings generalize to diverse populations remains unclear. We review longitudinal studies on STB risk factors over the past 50 years in the United States and evaluate the methodological practices of sampling and reporting sample characteristics. We found that articles frequently reported participant age and sex, less frequently reported participant race and ethnicity, and rarely reported participant veteran status or lesbian, gay, bisexual, and transgender status. Sample reporting practices modestly and inconsistently improved over time. Finally, articles predominantly featured White, non-Hispanic, young adult samples. © 2017 The American Association of Suicidology.

  20. Optimizing the triple-axis spectrometer PANDA at the MLZ for small samples and complex sample environment conditions

    Science.gov (United States)

    Utschick, C.; Skoulatos, M.; Schneidewind, A.; Böni, P.

    2016-11-01

    The cold-neutron triple-axis spectrometer PANDA at the neutron source FRM II has been serving an international user community studying condensed matter physics problems. We report on a new setup, improving the signal-to-noise ratio for small samples and pressure cell setups. Analytical and numerical Monte Carlo methods are used for the optimization of elliptic and parabolic focusing guides. They are placed between the monochromator and sample positions, and the flux at the sample is compared to the one achieved by standard monochromator focusing techniques. A 25 times smaller spot size is achieved, associated with a factor of 2 increased intensity, within the same divergence limits, ± 2 ° . This optional neutron focusing guide shall establish a top-class spectrometer for studying novel exotic properties of matter in combination with more stringent sample environment conditions such as extreme pressures associated with small sample sizes.