WorldWideScience

Sample records for sampling puncture guided

  1. CT-guided puncture

    International Nuclear Information System (INIS)

    Noeldge, G.; Richter, G.M.; Grenacher, L.; Brado, M.; Kauffmann, G.W.

    1996-01-01

    Sonographic and CT-guided punctures allow the evaluation of suspected lesions in the head, thorax, abdomen, retroperitoneum and skeletal system. The size of the lesion to be evaluated determines the size and the diameter of the puncture needle. The quantity of the material obtained will be defined by the diameter of the needle, i.e. fine-needle biopsy is more adequate for cytological than for histological evaluation. Strict adherence to the indications and contraindications for puncture and painstaking performance of the procedure go a long why towards minimizing the complications. The advantage of CT-guided puncture, in contrast to an ultrasound-guided procedure, is visualization during the puncture procedure free from overshadowing. This permits punctures of lesions located deep in the thorax or the abdomen which are overshadowed by the lungs, by air in the small or large bowel or by bone structures. Moreover, this technique yields much more information about the tissues and organs surrounding the suspected lesion. This information is much more investigator-related with ultrasoundguided puncture. Therefore, the CT-guided puncture has become mandatory in the evaluation of suspected lesions. Moreover, using the same technique, percutaneous drainage of fluids in the interpleural space, abscesses in organs, hematomas, lymphoceles and urinomas; ablation of metastases; and sympathicolysis can be carried out. CT-guided puncture thus changes from a minimally invasive diagnostic procedure to a minimally invasive therapy. (orig./MG) [de

  2. The transabdominal chorionic villus sampling puncture guided by color Doppler ultrasound during early pregnancy

    International Nuclear Information System (INIS)

    Liang Weixiang; Chen Zhiyi; Yuan Wenlin; Cai Kuan; Zhu Junlin; Wang Weiqun; Chen Xia

    2008-01-01

    Objective: To study the operation of chorionic villus sampling (CVS) guided by color Doppler ultrasound (CDU) via abdomen puncture during early pregnancy and investigate the advertences during the operation. Methods: CVS guided by CDU probe via abdomen puncture were operated on 28 pregnant women who had the indications of antenatal diagnosis. CDU was used to observe the implantation position of the fo1iaceous villis and help setting mark of the puncture point and puncture range on body surface before operation. The needle was punctured under real-time ultrasound guidance and villis were aspirated during the operation: The choice of the right time of puncture and the operation skills were emphasized in the study. Results: The CVS puncture approach should be set through CDU ob servation, which attend to avoid the surrounding blood vessels, intestinal canal and surrounding important organs. The puncture point should be chosen in a point where lobif0rmed villis distributed wider and with a larger scope. The operations were performed from 10 to13 weeks of pregnancy, with an average of 11 weeks. Among these 28 cases, 9.6 were successfully drawn materials in one time, 1 in twice and l failure, with the total ratio of achievement was 96.4%. For all the cases, fetal heart pulsating could be seen by real-time CDU observation fight after the operation, and no larger hematoma echo in the placental site occurred. Ultrasound reexamined one week after the operation, fetal heart pulsation could be found in all cases, and no abortion cases occurred after regular follow-up in 25 continued pregnant patients. Conclusion: Abdominal CVS puncture guided by CDU probe is conveniently operated, safe and available in clinic. It is an important method for antenatal diagnosis during early pregnancy. The puncture localization, skills and the time are the key points for the success in obtaining the materials. (authors)

  3. Clinical application of CT-guided percutaneous puncturing biopsy of subcarinal lymph node

    International Nuclear Information System (INIS)

    Yuan Xiaodong; Wang Jianhua; Zuo Changjing; Tian Jianming

    2011-01-01

    Objective: To discuss the safety and clinical significance of CT-guided percutaneous puncturing biopsy of subcarinal lymph node. Methods: During the period of July 2006-July 2010, CT-guided percutaneous puncturing biopsy of subcarinal lymph node was carried out in 17 patients (11 males and 6 females, with an average age of 54 years) with enlarged subcarinal lymph nodes. The clinical data were retrospectively analyzed. Immediately after the puncturing procedure was completed, CT scanning was performed to observe if there any complications and to evaluate the safety of puncturing biopsy. Biopsy specimens were sent for pathological examination to assess the puncturing accuracy and to make the pathologic diagnosis. The clinical usefulness of this technique was evaluated. Results: Of the total 17 cases, successful puncturing into the enlarged subcarinal lymph nodes with single procedure was achieved in 14 and sufficient tissue sample was obtained. The biopsy failed in three cases at initial puncturing procedure as the needle could not be placed into the enlarged subcarinal lymph nodes, the puncturing biopsy had to given up in two patients because of hemoptysis and in another patient the second puncturing biopsy performed one week later was successful. The total technical successful rate was 88.2% (15/17). Of the fifteen cases with successful puncturing, definitive pathological diagnosis was obtained in 13 and the diagnosis was uncertain in the remaining two, with a diagnosis positive rate of 86.7% (13/15). Pathologically, the diagnoses included metastatic lymphadenopathy from lung cancer (n=10), proliferative inflammatory lymphadenopathy (n=2) and tuberculous enlargement of lymph nodes (n=1). Complications occurred in 4 patients (23.5%, 4/17), which mainly were pneumothorax and pulmonary hemorrhage. Conclusion: With high successful rate and diagnostic accuracy, CT-guided percutaneous puncturing biopsy of subcarinal lymph node is a safe and effective technique if the

  4. Ultrasound-guided lumbar puncture in pediatric patients: technical success and safety.

    Science.gov (United States)

    Pierce, David B; Shivaram, Giri; Koo, Kevin S H; Shaw, Dennis W W; Meyer, Kirby F; Monroe, Eric J

    2018-06-01

    Disadvantages of fluoroscopically guided lumbar puncture include delivery of ionizing radiation and limited resolution of incompletely ossified posterior elements. Ultrasound (US) allows visualization of critical soft tissues and the cerebrospinal fluid (CSF) space without ionizing radiation. To determine the technical success and safety of US-guided lumbar puncture in pediatric patients. A retrospective review identified all patients referred to interventional radiology for lumbar puncture between June 2010 and June 2017. Patients who underwent lumbar puncture with fluoroscopic guidance alone were excluded. For the remaining procedures, technical success and procedural complications were assessed. Two hundred and one image-guided lumbar punctures in 161 patients were included. Eighty patients (43%) had previously failed landmark-based attempts. One hundred ninety-six (97.5%) patients underwent lumbar puncture. Five procedures (2.5%) were not attempted after US assessment, either due to a paucity of CSF or unsafe window for needle placement. Technical success was achieved in 187 (95.4%) of lumbar punctures attempted with US guidance. One hundred seventy-seven (90.3%) were technically successful with US alone (age range: 2 days-15 years, weight range: 1.9-53.1 kg) and an additional 10 (5.1%) were successful with US-guided thecal access and subsequent fluoroscopic confirmation. Three (1.5%) cases were unsuccessful with US guidance but were subsequently successful with fluoroscopic guidance. Of the 80 previously failed landmark-based lumbar punctures, 77 (96.3%) were successful with US guidance alone. There were no reported complications. US guidance is safe and effective for lumbar punctures and has specific advantages over fluoroscopy in pediatric patients.

  5. CT-guided puncture for direct MR-arthrography of the shoulder: Description of possible techniques

    Directory of Open Access Journals (Sweden)

    Hauth E

    2016-07-01

    Full Text Available The following report describes the possible techniques of CT-guided puncture for direct magnetic resonance (MR arthrography of the shoulder. CT-guided puncture can be regarded as an alternative technique to fluoroscopic- or ultrasound-guided puncture for MR-arthrography of the shoulder with high efficiency, low dose and extremely low complication rate.

  6. Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture

    International Nuclear Information System (INIS)

    Hirata, Masaaki; Watanabe, Ryouhei; Koyano, Yasuhiro; Sugata, Shigenori; Takeda, Yukie; Nakamura, Seiji; Akamune, Akihisa; Tsuda, Takaharu; Mochizuki, Teruhito

    2017-01-01

    PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.

  7. Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Masaaki, E-mail: masaaki314@gmail.com [Matsuyama Shimin Hospital, Department of Radiology (Japan); Watanabe, Ryouhei; Koyano, Yasuhiro [Matsuyama Shimin Hospital, Department of Surgery (Japan); Sugata, Shigenori; Takeda, Yukie [Ehime Prefectural Imabari Hospital, Department of Radiology (Japan); Nakamura, Seiji; Akamune, Akihisa [Matsuyama Shimin Hospital, Department of Radiology (Japan); Tsuda, Takaharu; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology (Japan)

    2017-04-15

    PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.

  8. CT guided puncture aspiration and sclerosing treatment of ovary cyst

    International Nuclear Information System (INIS)

    Peng Yongjun; Du Xiumei; Yuan Jinrong; Chen Chanqing

    2007-01-01

    Objective: To analyze the method and the curative effect with CT guided percutaneous puncture aspiration and sclerosing treatment of ovary cyst. Method: 22 ovary cysts in 22 patients were treated with percutaneous puncture aspiration and underwent repeated sclerotherapy with 99.7% ethanol injection. Among the 22 patients, 18 patients had solitary ovary cyst and was aspirated with an 18-22G gauge aspiration needle. The amount of aspirated fluid varied from 30ml-500ml and 25%-30% cyst volume was replaced by appropriate ethanol Post treatment follow-up were achieved every 3 months. Results All the Punctures were successfully completed. During the 3 months to one year follow-up, 16 ovary cyst disappeared, 6 cysts were small over 50%, without main complication. Conclusion CT guided percutaneous puncture aspiration and sclerosing treatment of ovary cyst is a treatment of choice because of its safety, low complication, and high curative effect. (authors)

  9. The clinical value of trans-vaginal ultrasound-guided puncture in the treatment of pelvic abscess

    International Nuclear Information System (INIS)

    Wang Ping; Gong Wei

    2008-01-01

    Objective: To investigate the clinical value of trans-vaginal ultrasound-guided (TVS) puncture in the treatment of pelvic abscess. Methods 30 cases with pelvic abscess were treated by transvaginal ultrasound-guided puncture. The long-dated effects were followed-up. Results: 29 cases were cured by TVS puncture. Operation was performed in 1 patient because of invalid effect. The cure rate was 97%. Conclusion: Ultrasound-guided puncture is a safe and convenient method in the treatment of pelvic abscess. (authors)

  10. Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Slattery, Michael M.; Goh, Gerard S.; Power, Sarah; Given, Mark F.; McGrath, Frank P.; Lee, Michael J., E-mail: mlee@rcsi.ie [Beaumont Hospital, Department of Radiology (Ireland)

    2015-06-15

    PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrade puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.

  11. Pre-puncture ultrasound guided epidural insertion before vaginal delivery.

    Science.gov (United States)

    Nassar, Mahmoud; Abdelazim, Ibrahim A

    2015-10-01

    Palpation method is widely used in clinical practice to identify the puncture site during combined spinal-epidural (CSE) blocks. Tuffier's line, is an anatomical landmark between two iliac crests (inter-cristal), which is widely used to identify the puncture site during CSE blocks is not always an indicator for specific vertebral level or inter-vertebral space. One hundred and Ten (110) women were scheduled for normal vaginal delivery and were randomized into two equal groups; palpation group and an ultrasound guided group to detect the efficacy of puncture ultrasound before CSE blocks to increase chances of successful CSE procedure on the first attempt and to reduce the number of attempts or punctures during insertion of CSE catheter. There were no significant differences between two studied groups regarding; maternal age, weight and height, while, there was a significant difference between two studied groups regarding; parity. Percentage of successful CSE procedure on the first attempt was significantly higher (67.27%) in ultrasound compared to palpation group (40%). Number of punctures (attempts) were significantly less in ultrasound (1.2 ± 0.6) compared to palpation group (2.3 ± 0.8) and the number of redirections was also significantly less in ultrasound (1.4 ± 0.5) compared to palpation group (2.8 ± 1.6). Although, time to identify puncture site was significantly longer in ultrasound compared to palpation group and total procedure time was longer in ultrasound (9.1 ± 1.5 min) compared to palpation group (6.2 ± 1.2 min), there was no significant difference between two studied groups regarding; time to identify puncture site and total procedure time. Two cases of dural puncture in palpation versus no cases in ultrasound group and two cases of intravascular catheter placement (one in each group), with no significant difference between two groups. Pre- puncture ultrasound guided epidural insertion before vaginal delivery, increases the chance of a

  12. Hybrid Approach for Biliary Interventions Employing MRI-Guided Bile Duct Puncture with Near-Real-Time Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wybranski, Christian, E-mail: Christian.Wybranski@uk-koeln.de [University Hospital of Cologne, Department of Diagnostic and Interventional Radiology (Germany); Pech, Maciej [Otto-von-Guericke University Medical School, Department of Radiology and Nuclear Medicine (Germany); Lux, Anke [Otto-von-Guericke University Medical School, Institute of Biometry and Medical Informatics (Germany); Ricke, Jens; Fischbach, Frank; Fischbach, Katharina [Otto-von-Guericke University Medical School, Department of Radiology and Nuclear Medicine (Germany)

    2017-06-15

    ObjectiveTo assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture.MethodsA total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded.ResultsVisualization even of third-order non-dilated BD and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16–11:07) min. and 3:58 ± 2:35 (1:11–9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications.ConclusionA hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.

  13. CT guided percutaneous renal cysts puncture with ethanol therapy

    International Nuclear Information System (INIS)

    Zhang Xuezhe; Lu Yan; Wang Wu; Huang Zhengguo; Ren An

    2002-01-01

    Objective: To analyse our clinical experience with CT guided percutaneous renal cysts puncture and ethanol therapy. Methods: Five hundred and ten renal cysts in 445 patients were undergone CT guided percutaneous renal cysts puncture and ethanol therapy. Among the 445 cases, 385 cases had solitary renal cyst, 53 multiple renal cysts, and 7 polycystic kidneys. The renal cysts varied in size from 1.9 to 13.5 cm in diameter. The amount of aspirated fluid varied from 3 to 780 ml. A 18-21 gauge aspiration needles were used for all patients. A 25.0% cyst volume replacement with 99.7% ethanol was approved to be appropriate. Results: 427 renal cysts in 396 patients were followed up by computed tomographic (CT) or ultrasound for less than 3 months to more than one year duration. The curative effective rate and disappearance rate of the renal cystic cavity in solitary renal cysts were 97% and 82%, respectively. In multiple renal cysts, the corresponding values were 95% and 79%. In polycystic kidneys, the curative rate was 67%. The complications such as local abdominal pain (28 cases) and hematuria (four cases) were observed in this series. There were no fatal complications. Conclusions: CT guided percutaneous renal cyst puncture and ethanol therapy is an useful procedure for the treatment of solitary renal cysts and multiple renal cysts

  14. Gelatin model for training ultrasound-guided puncture

    Directory of Open Access Journals (Sweden)

    Alexandre Campos Moraes Amato

    2015-09-01

    Full Text Available BACKGROUND: It is indispensable that members of the medical profession receive the technical training needed to enable them to rapidly obtain effective vascular access. Training procedures should be used judiciously to familiarize students with the technique. However, existing models are expensive or ineffective, and models need to be developed that are similar to what will be encountered in real patients.OBJECTIVES: To demonstrate creation and application of a gelatin model for training ultrasound-guided puncture.METHOS: The model was made using a mixture of colorless gelatin and water in a transparent plastic receptacle with two pairs of orifices of different diameters, through which two plastic tubes were inserted, to simulate blood vessels.RESULTS: The model was a close approximation to the real medical procedure in several aspects, since gelatin has a similar consistency to human tissues, providing a more faithful reproduction of the tactile sensation at the moment when the needle reaches the interior of a vessel and its contents are aspirated.CONCLUSIONS: The method proposed here can be used to easily construct a low-cost model using everyday materials that is suitable for large-scale training of ultrasound-guided puncture.

  15. A New Ultrasound-Guided Puncture Device with Augmented Degrees of Performance Freedom and Ability to Attach to Most Convex Probes

    International Nuclear Information System (INIS)

    Jung, Sung Il; Son, Kyu Ri; Kim, Young Jun; Jeon, Hae Jeong; Park, Sang Woo; Cho, Jeong Yeon; Kim, Seung Hyup

    2008-01-01

    To evaluate the performance of a newly-designed ultrasound (US)-guided puncture device. A newly-designed US-guided puncture device was composed of a guide segment and an attachable segment. The guide segment allowed the needle to be placed in the plane of US view with a maximal degree of freedom, and the attachable segment was designed to attach to most convex US probes. Six operators punctured 144 targets in phantoms using either the new device (n = 72) or free-hand technique (n = 72). The number of required needle passages and the necessary procedure times were compared between the two groups. The number of required needle passages and the necessary procedure time were significantly reduced in five operators when the newly-designed US-guided puncture device was used (p < 0.05). A newly-designed US-guided puncture device, which allows for a maximal degree of freedom in needle placement and can attach to most convex US probes, showed good performance in our study

  16. Study of DSA-guided percutaneous puncture location of foramen oval

    International Nuclear Information System (INIS)

    Zhao Xiaojun; He Jiawei; Bai Guanghui; Shi Jianjing; Xu Chongyong; Zhan Gonghao

    2008-01-01

    Objective: To study the technique of digital substraction angiography (DSA)-guided percutaneous puncture location of foramen oval. Methods: 39 cases of trigeminal neuralgia were included in the study from Feb. 2004 to Oct. 2006. The patients were punctured by the amending anterior position. The f0ramen oval was displayed by moving the tube tilted 20-28 degree to the caudal and 16-23 degree to the healthy side. The direction and depth of the needles was determined on the lateral view. Then, radio-frequency thermocoagulation therapy was performed. Results: The needles were located in oval foramen in all the patients. Pain disappeared in 36 cases, alleviated in other cases, and no serious complication occurred during therapy. Conclusions: Oval foramen locations by DSA can improve the successful rate of operation. The foramen oval can be clearly displayed by DSA-guided in amending position, with comfortable position for patients. (authors)

  17. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    Science.gov (United States)

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (Ptennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  18. A New Navigation System of Renal Puncture for Endoscopic Combined Intrarenal Surgery: Real-time Virtual Sonography-guided Renal Access.

    Science.gov (United States)

    Hamamoto, Shuzo; Unno, Rei; Taguchi, Kazumi; Ando, Ryosuke; Hamakawa, Takashi; Naiki, Taku; Okada, Shinsuke; Inoue, Takaaki; Okada, Atsushi; Kohri, Kenjiro; Yasui, Takahiro

    2017-11-01

    To evaluate the clinical utility of a new navigation technique for percutaneous renal puncture using real-time virtual sonography (RVS) during endoscopic combined intrarenal surgery. Thirty consecutive patients who underwent endoscopic combined intrarenal surgery for renal calculi, between April 2014 and July 2015, were divided into the RVS-guided puncture (RVS; n = 15) group and the ultrasonography-guided puncture (US; n = 15) group. In the RVS group, renal puncture was repeated until precise piercing of a papilla was achieved under direct endoscopic vision, using the RVS system to synchronize the real-time US image with the preoperative computed tomography image. In the US group, renal puncture was performed under US guidance only. In both groups, 2 urologists worked simultaneously to fragment the renal calculi after inserting the miniature percutaneous tract. The mean sizes of the renal calculi in the RVS and the US group were 33.5 and 30.5 mm, respectively. A lower mean number of puncture attempts until renal access through the calyx was needed for the RVS compared with the US group (1.6 vs 3.4 times, respectively; P = .001). The RVS group had a lower mean postoperative hemoglobin decrease (0.93 vs 1.39 g/dL, respectively; P = .04), but with no between-group differences with regard to operative time, tubeless rate, and stone-free rate. None of the patients in the RVS group experienced postoperative complications of a Clavien score ≥2, with 3 patients experiencing such complications in the US group. RVS-guided renal puncture was effective, with a lower incidence of bleeding-related complications compared with US-guided puncture. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Application of C-arm CT-guided targeted puncturing technique in performing non-vascular interventional biopsy or interventional therapy

    International Nuclear Information System (INIS)

    Li Zhen; Han Xinwei; Jiao Dechao; Ren Jianzhuang; Su Yu; Ye Hui

    2011-01-01

    Objective: to investigate the clinical value of C-arm CT-guided targeted puncturing technique in performing non, vascular interventional biopsy or interventional therapy. Methods: Thirty, one patients, who were encountered in authors' hospital during the period from July 2010 to September 2010, were involved in this study. C-arm CT-guided percutaneous targeted puncturing biopsy or interventional therapy was performed in all 31 patients. All patients had complete clinical data. The complications and positive rate of biopsy were recorded and analyzed. Results: Under C-arm CT-guidance, percutaneous interventional therapy was carried out in 13 patients. The interventional procedures included radiofrequency ablation therapy for hepatic cellular carcinoma (n=2), pelvic abscess draining (n=1), hepatic abscess draining (n=1), ethanol injection for liver cancer (n=4), sclerotic therapy with ethanol injection for renal cyst (n=2), sclerotic therapy with ethanol injection for liver cyst (n=2) and catheter-indwelling drainage for pancreatic pseudocyst (n=1). percutaneous interventional biopsy was performed in the remaining 18 cases, including liver (n=4), lung (n=7), mediastinum (n=2), bone and soft tissue (n=4) and neck mass (n=1). All the procedures were successfully accomplished, no technique, related complications occurred during the operation. For biopsy examination in 18 cases, the positive rate was 94.4% (17/18) and false, negative results was seen in one case with lung lesion. Conclusion: The percutaneous targeted puncturing technique with C, arm CT-guidance combines the advantages of both CT scanning and fluoroscopy. The use of real, time road, mapping function can effectively guide the puncturing and therapeutic management, which can not only optimize the workflow, save the operation time, but also improve the success rate and technical safety. Therefore, it is of great value to popularize this targeted puncturing technique. (authors)

  20. CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk [Hammersmith Hospital, Department of Radiology, Imperial College Healthcare NHS Trust (United Kingdom)

    2016-04-15

    PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNo immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.

  1. Transforaminal Lumbar Puncture: An Alternative Technique in Patients with Challenging Access.

    Science.gov (United States)

    Nascene, D R; Ozutemiz, C; Estby, H; McKinney, A M; Rykken, J B

    2018-05-01

    Interlaminar lumbar puncture and cervical puncture may not be ideal in all circumstances. Recently, we have used a transforaminal approach in selected situations. Between May 2016 and December 2017, twenty-six transforaminal lumbar punctures were performed in 9 patients (25 CT-guided, 1 fluoroscopy-guided). Seven had spinal muscular atrophy and were referred for intrathecal nusinersen administration. In 2, CT myelography was performed via transforaminal lumbar puncture. The lumbar posterior elements were completely fused in 8, and there was an overlying abscess in 1. The L1-2 level was used in 2; the L2-3 level, in 10; the L3-4 level, in 12; and the L4-5 level, in 2 procedures. Post-lumbar puncture headache was observed on 4 occasions, which resolved without blood patching. One patient felt heat and pain at the injection site that resolved spontaneously within hours. One patient had radicular pain that resolved with conservative treatment. Transforaminal lumbar puncture may become an effective alternative to classic interlaminar lumbar puncture or cervical puncture. © 2018 by American Journal of Neuroradiology.

  2. Usefulness of sono-guided needle puncture for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Choi, Jae Woong; Hong, Suk Ju; Suh, San Il; Yong, Hwan Suk; Kim, Jung Hyuk; Park, Cheol Min; Suh, Won Hyuck; Kim, Myung Gyu

    2000-01-01

    To evaluate the usefulness of sono-guided needle puncture for MR arthrography of the shoulder to locate the path of access and to control the correct placement of the needle into the shoulder. Fifteen patients with suspicion of shoulder pathology were included in this study. Patients were laid in supine positions with the arm extended and slightly abducted, the palm of the hand facing upward. A sonographic unit with a high resolution transducer with 7.5 MHz linear array was used. Axial images in the anterior aspect of the shoulder were obtained to localize the coracoid process and the anteromedical portion of the humerus. Using an aseptic technique, a 21-guage needle was advanced into the shoulder joint under ultrasonographic guidance. When the needle made contract with the articular cartilage of the humeral head, the needle was tiled to position is point in the articular cavity. Solution of 0.1 ml gadopentetate dimeglumine in 25 ml of normal saline was prepared and 12-16 ml was injected into the joint cavity. The intra-articular position of the needle and the compete distension of the shoulder joint were again confirmed by sonography. The needle was accurately placed in 14 out of 15 patients without damage to neighboring structures. It took 10 to 15 minutes to complete the procedure in 14 patients. No side effects attributable to gadopentetate dimeglumine were found. Sono-guided needle puncture for the shoulder MR arthrography can be a substitutable method for fluoroscopic guidance, with easy access, advantages of lacking radiation hazard and eliminating the need for iodized contrast agents.

  3. The training and learning process of transseptal puncture using a modified technique.

    Science.gov (United States)

    Yao, Yan; Ding, Ligang; Chen, Wensheng; Guo, Jun; Bao, Jingru; Shi, Rui; Huang, Wen; Zhang, Shu; Wong, Tom

    2013-12-01

    As the transseptal (TS) puncture has become an integral part of many types of cardiac interventional procedures, its technique that was initial reported for measurement of left atrial pressure in 1950s, continue to evolve. Our laboratory adopted a modified technique which uses only coronary sinus catheter as the landmark to accomplishing TS punctures under fluoroscopy. The aim of this study is prospectively to evaluate the training and learning process for TS puncture guided by this modified technique. Guided by the training protocol, TS puncture was performed in 120 consecutive patients by three trainees without previous personal experience in TS catheterization and one experienced trainer as a controller. We analysed the following parameters: one puncture success rate, total procedure time, fluoroscopic time, and radiation dose. The learning curve was analysed using curve-fitting methodology. The first attempt at TS crossing was successful in 74 (82%), a second attempt was successful in 11 (12%), and 5 patients failed to puncture the interatrial septal finally. The average starting process time was 4.1 ± 0.8 min, and the estimated mean learning plateau was 1.2 ± 0.2 min. The estimated mean learning rate for process time was 25 ± 3 cases. Important aspects of learning curve can be estimated by fitting inverse curves for TS puncture. The study demonstrated that this technique was a simple, safe, economic, and effective approach for learning of TS puncture. Base on the statistical analysis, approximately 29 TS punctures will be needed for trainee to pass the steepest area of learning curve.

  4. Comparative study of decomposable and indecomposable biopsy needle in lung puncture biopsy

    International Nuclear Information System (INIS)

    Wang Bo; Sheng Zhanxin; Wen Yamin; Zhang Liping; Wen Zongqiu

    2007-01-01

    Objective: To contrast the clinical practice characteristics with decomposable and indecomposable biopsy needle in the CT-guided lung puncture biopsy. Methods: 50 patients with lung tumour carried on puncture biopsy under the CT guidance were divided in two groups randomly: Group A (25 examples): using the indecomposable BioPinceTM biopsy needle; Group B(25 examples): using the decomposable Precisa or Vitesse biopsy needle. The puncture biopsy organization quantity, the first time puncture success rate, the pathological diagnosis result and the incidence of puncture complication were compared in two groups. Results: More striped structures were gained obviously in group A than in group B: 24/25 and 11/25 respectively (P>0.05), The pathological diagnosis 'serious extrusion amoebocyte and nature undetermined' only occurred in group B. But the first time puncture success rate was lower in group A than in B: 52%(13/25) and 80%(20/25) respectively (P>0.05), The incidence of hemorrhage and pneumothorax in group A was higher slightly: 84% and 72%, 16% and 4% respectively (P>0.05). Conclusion: The indecomposable needle (BioPinceTM) was better in lung puncture biopsy, but the lower first time puncture success rate also increases the risk of operation and complication in some degree because of the structure of the needle. On the contrary, decomposable needle (the Precisa or the Vitesse) was not the best choice in lung puncture biopsy. But it had the original superiority, especially regarding the special patient such as patient with small tumour, thin thoracic wall, bad physique for its nimble operation. It is essential for us to use the two different types of biopsy needle rationally to enhance the level of CT-guided lung puncture biopsy. (authors)

  5. Validation of a novel cost effective easy to produce and durable in vitro model for kidney-puncture and PNL-Simulation.

    Science.gov (United States)

    Klein, Jan Thorsten; Rassweiler, Jens; Rassweiler-Seyfried, Marie-Claire Charlotte

    2018-03-29

    Nephrolithiasis is one of the most common diseases in urology. According to the EAU Guidelines, a percutaneous nephrolitholapaxy (PNL) is recommended when treating a kidney stone >2 cm. Nowadays PNL is performed even for smaller stones (PNL is the puncture of the planned site. PNL-novice surgeons need to practice this step in a safe environment with an ideal training model. We developed and evaluated a new, easy to produce, in-vitro model for the training of the freehand puncture of the kidney. Porcine kidneys with ureters were embedded in ballistic gel. Food coloring and preservative agent were added. We used the standard imaging modalities of X-ray and ultrasound to validate the training model. An additional new technique, the iPAD guided puncture, was evaluated. Five novices and three experts conducted 12 punctures for each imaging technique. Puncture time, radiation dose, and number of attempts to a successful puncture were measured. Mann-Whitney-U, Kruskal-Wallis, and U-Tests were used for statistical analyses. The sonographic guided puncture is slightly but not significantly faster than the fluoroscopic guided puncture and the iPAD assisted puncture. Similarly, the most experienced surgeon's time for a successful puncture was slightly less than that of the residents, and the experienced surgeons needed the least attempts to perform a successful puncture. In terms of radiation exposure, the residents had a significant reduction of radiation exposure compared to the experienced surgeons. The newly developed ballistic gel kidney-puncture model is a good training tool for a variety of kidney puncture techniques, with good content, construct, and face validity.

  6. CT fluoroscopy-assisted puncture of thoracic and abdominal masses: a randomized trial.

    Science.gov (United States)

    Kirchner, Johannes; Kickuth, Ralph; Laufer, Ulf; Schilling, Esther Maria; Adams, Stephan; Liermann, Dieter

    2002-03-01

    We investigated the benefit of real-time guidance of interventional punctures by means of computed tomography fluoroscopy (CTF) compared with the conventional sequential acquisition guidance. In a prospective randomized trial, 75 patients underwent either CTF-guided (group A, n = 50) or sequential CT-guided (group B, n = 25) punctures of thoracic (n = 29) or abdominal (n = 46) masses. CTF was performed on the CT machine (Somatom Plus 4 Power, Siemens Corp., Forchheim, Germany) equipped with the C.A.R.E. Vision application (tube voltage 120 kV, tube current 50 mA, rotational time 0.75 s, slice thickness 10 mm, 8 frames/s). The average procedure time showed a statistically significant difference between the two study groups (group A: 564 s, group B 795 s, P = 0.0032). The mean total mAs was 7089 mAs for the CTF and 4856 mAs for the sequential image-guided intervention, respectively. The sensitivity was 71% specificity 100% positive predictive value 100% and negative predictive value 60% for the CTF-guided puncture, and 68, 100, 100 and 50% for sequential CT, respectively. CTF guidance realizes a time-saving but increases the radiation exposure dosage.

  7. The zero-wall puncture: a novel angiographic puncture technique with substantial benefits

    International Nuclear Information System (INIS)

    Leswick, D.A.; Szkup, P.; Stoneham, G.W.

    2005-01-01

    Medical education can be busy, exhausting, and stressful, with potential adverse effects on trainees' physical and mental health. Radiology residency is no exception. In addition to increased daily workload and study requirements, Canadian radiology residents are performing a diverse and increasing number of emergent diagnostic examinations after hours. In an attempt to improve resident self-worth and efficiency during angiographic rotations, we investigated the effects of a novel angiographic puncture procedure on various resident lifestyle indexes. Standard techniques for accessing the femoral artery are either the single-wall puncture or double-wall puncture (Seldinger technique). Both of these techniques are widely known and practiced. Following procedure completion, hemostasis must be achieved at the puncture site. This has traditionally required manual compression at the puncture site, which may require 15 to 20 minutes. At our institution the standard policy is that 'whoever makes the puncture, compresses the groin,' also known as 'you broke it, you fix it'. This has prompted our industrious resident complement to develop a novel, previously undescribed, angiographic puncture technique known as the 'zero-wall puncture technique.' Preliminary unpublished results from our institution show that when residents employ the zero-wall puncture technique the attending staff radiologist subsequently both performs the puncture and compresses the groin at the end of the procedure. We investigated the effect of zero-wall puncture on various resident lifestyle indexes. (author)

  8. Percutaneous Direct Puncture Embolization with N-butyl-cyanoacrylate for High-flow Priapism

    Energy Technology Data Exchange (ETDEWEB)

    Tokue, Hiroyuki, E-mail: tokue@s2.dion.ne.jp; Shibuya, Kei [Gunma University Hospital, Department of Diagnostic and Interventional Radiology (Japan); Ueno, Hiroyuki [Isesaki Municipal Hospital, Department of Radiology (Japan); Tokue, Azusa; Tsushima, Yoshito [Gunma University Hospital, Department of Diagnostic and Interventional Radiology (Japan)

    2016-09-15

    There are many treatment options in high-flow priapism. Those mentioned most often are watchful waiting, Doppler-guided compression, endovascular highly selective embolization, and surgery. We present a case of high-flow priapism in a 57-year-old man treated by percutaneous direct puncture embolization of a post-traumatic left cavernosal arteriovenous fistula using N-butyl-cyanoacrylate. Erectile function was preserved during a 12-month follow-up. No patients with percutaneous direct puncture embolization for high-flow priapism have been reported previously. Percutaneous direct puncture embolization is a potentially useful and safe method for management of high-flow priapism.

  9. Transfundal puncture of a large ovarian cyst with hysteroscopic and ultrasonographic guidance

    Directory of Open Access Journals (Sweden)

    Zolnierczyk P

    2015-05-01

    Full Text Available Piotr Zolnierczyk, Krzysztof Cendrowski, Wlodzimierz Sawicki Department of Obstetrics, Gynecology and Oncology, 2nd Faculty of Medicine, Medical University of Warsaw, Warsaw, Poland Abstract: This paper describes the case of an 83-year-old patient with hypertension, diabetes, obesity (body mass index – 38, congestive heart failure, and history of cardiac surgery, who was referred for a diagnostic–therapeutic decompression of a large, symptomatic ovarian cyst. Due to anatomical conditions, the only safe way was a transfundal puncture under mini-hysteroscopic and ultrasound guidance. A puncture with aspiration of 300 mL of serous fluid from the cyst was performed without technical problems and complications. Cytology showed no cancer cells in the examined liquid. Relief from pain and compression discomfort was achieved in the patient. This case shows the possibility of combining ultrasound and minimally invasive diagnostic methods like hysteroscopy in selected clinical situations. Keywords: ovarian cyst puncture, hysteroscopy, ultrasound guided puncture, transfundal cyst puncture, vaginoscopy 

  10. Tracheobronchial puncture-site nodular reaction (TPNR following endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA: Systematic review of case reports

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2017-01-01

    Full Text Available Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA is a minimally invasive and efficacious diagnostic modality for lung cancer staging and evaluation of undiagnosed mediastinal lymphadenopathy. Procedure-related complications are uncommon. We herein report an infrequently described phenomenon following EBUS-TBNA in which two patients developed nodular granulation tissue at the tracheobronchial puncture site. On systematic review, we found description of such phenomena by terminologies such as endobronchial inflammatory polyp, granuloma, and endobronchial mass. The endobronchial inflammatory polyp has been one of the most commonly used terminologies for these; but in most cases, the classical features of an inflammatory polyp are lacking. We propose the term, tracheobronchial puncture-site nodular reaction (TPNR with further classification into granulomatous and nongranulomatous subtypes, for standardized reporting of such reactions following transbronchial needle aspiration procedures. Knowledge of this entity and standardized nomenclature shall help in better characterization of the outcomes and risk factors for the occurrence of these reactions.

  11. Clinical application of percutaneous lumbar puncture to treat sciatica caused by lumbar disc herniation under CT guidance

    International Nuclear Information System (INIS)

    Wang Linyou; Li Yuan; Shao Yangtong

    2004-01-01

    Objective: To evaluate the effect of the percutaneous lumbar puncture to treat sciatica caused by lumbar disc herniation. Methods: 75 cases of lumbar disc herniation with significant clinical signs were confirmed by CT scan. The technique of the percutaneous lumbar puncture led the needle to approach nerve root and injected medicine diffusing into extraduramater, and then relieved the symptom of sciatica. Results: The rate of success of percutaneous lumbar puncture guided by CT reached to 100%. After two weeks of follow-up, the symptom of pain was obviously improved and disappeared in 63.3% cases. There were 23.0% cases needed a second procedure, and no change was obsesved in 9.3% cases. Conclusions: The percutaneous lumbar puncture guided by CT to treat sciatica resulted from lumbar disc herniation is one of the safe, reliable, effective new methods with no complication. The long term effectiveness is still in need of investigation. (authors)

  12. Anatomic landmarks of fluoroscopy guided puncture of the pulseless femoral artery

    International Nuclear Information System (INIS)

    Jeon, Min Hee; Han, Gi Seok; Kim, Sung Jin; Park, Kil Sun; Cha, Sang Hoon; Bae, Il Hun; Lee, Seung Young

    2006-01-01

    We wanted to improve puncturing the pulseless femoral artery by evaluating the anatomic landmarks that suggest the course of the femoral artery on fluoroscopy. We analyzed 37 hemipelvis spot images that were centered on the arterial sheath after puncture of the femoral artery. The inguinal angles were measured between the inguinal line connecting the anterior superior iliac spine and the symphysis pubis, and the line of the arterial sheath. Inguinal ligament ratios were measured as the distance from the symphysis pubis to the arterial sheath to the length of the inguinal ligament on the inguinal line. The femoral head ratios were measured as the distance from the medial margin of the femur head to the arterial sheath to the transverse length of the femur head. The mean inguinal angle was 66.5 and the mean inguinal ligament ratio was 0.42 (± 0.03). The mean femoral head ratio was 0.08 (± 0.18). In comparing the men and women, there was no significant difference in the inguinal angle and the femoral head ratio, but the inguinal distance ratio was larger in women (men: 0.41 ± 0.033, women: 0.44 ± 0.031, ρ < 0.05). The femoral artery generally courses just lateral to the medial margin of the femur head (femoral head ratio: 0.08) and the medial 40% of the inguinal ligament (inguinal ligament ratio: 0.42). So, consideration of these relations may be helpful for puncturing the pulseless femoral artery

  13. RS3PE Syndrome with Iliopsoas Bursitis Distinguished from an Iliopsoas Abscess Using a CT-guided Puncture.

    Science.gov (United States)

    Fukui, Shoichi; Iwamoto, Naoki; Tsuji, Sosuke; Umeda, Masataka; Nishino, Ayako; Nakashima, Yoshikazu; Suzuki, Takahisa; Horai, Yoshiro; Koga, Tomohiro; Kawashiri, Shin-ya; Ichinose, Kunihiro; Hirai, Yasuko; Tamai, Mami; Nakamura, Hideki; Origuchi, Tomoki; Kawakami, Atsushi

    2015-01-01

    A 55-year-old man was diagnosed with remitting seronegative symmetrical synovitis with pitting edema (RS3PE) syndrome. Contrast-enhanced computed tomography for cancer screening showed a mass with low-density centers with an enhanced rim in the left iliopsoas muscle. We suspected an iliopsoas abscess and performed computed-tomography-guided puncture of the mass. Both Gram staining and the culture of the fluid were negative. We diagnosed the patient with RS3PE syndrome with iliopsoas bursitis and administered low-dose corticosteroids without antibiotics. The symptoms, including left hip pain, quickly disappeared following treatment. Clinicians should be aware that iliopsoas bursitis may resemble an iliopsoas abscess. As a result, it is important to make an accurate differential diagnosis.

  14. Puncture panel optimization

    International Nuclear Information System (INIS)

    Glass, R.E.; Longenbaugh, R.S.

    1986-01-01

    Sandia National Laboratories developed the TRansUranic PACkage Transporter (TRUPACT) to transport defense contact-handled transuranic wastes. The package has been designed to meet the normal and hypothetical accident conditions in 10CFR71 which includes the demonstrated ability to survive a 1-meter drop onto a mild steel pin. The puncture protection is provided by puncture resistant panels. In conjunction with the development of TRUPACT, a series of experiments has been conducted to reduce the weight of the puncture resistant panels. The initial scoping tests resulted in a preliminary design incorporating 30 layers of Kevlar. This design has been shown to meet the regulatory puncture test. To reduce the weight of this panel, subscale tests were conducted on panels utilizing Kevlar yarns with varying mass per unit length (denier) as well as different resins. This paper reviews the testing undertaken in the original panel development and discusses the results obtained from the recent subscale and full-scale optimization tests

  15. Use of a vegetable model as a training tool for PCNL puncture.

    Science.gov (United States)

    Sinha, Maneesh; Krishnamoorthy, Venkatesh

    2015-01-01

    Training residents to perform a PCNL puncture is hampered by the non-availability of a good inanimate model that can be used for demonstration and practice. The ethics of surgical training during actual surgeries is being questioned and the role of simulation is increasingly important. Virtual reality trainers, however, are prohibitively expensive and the use of animal models is fraught with regulatory and ethical concerns. We have devised a model that can be used to teach the concept of depth perception during a PCNL puncture. A bottle gourd was used to mimic the posterior abdominal wall. Cotton pledgets dipped in intravenous contrast were fitted into 4 mm holes made at staggered levels in the bottle gourd which was strapped onto the operating table with the cotton pledgets facing away from the surgeon. Surgeons with varying degrees of experience made fluoroscopy-guided punctures onto the cotton pledgets. We recorded the time taken for puncture in seconds and the distance of the needle exit site from the center of the cotton ball. Speed was measured by recording the fluoroscopy time in seconds on the C-arm. Accuracy was documented by using a Vernier caliper to measure the distance from the edge of the target to the actual puncture. One second of fluoroscopy time and 0.1 mm distance were each given one point. The total points accumulated over a set of 10 punctures was added to give a total score. Longer fluoroscopy times and inaccurate punctures resulted in higher scores. A surgeon with more than 1000 PCNLs to his credit had a score of 99. The average score of five residents was 555. The bottle gourd model provides an ethically acceptable, inexpensive, easy to replicate model that can be used to train residents in the PCNL puncture.

  16. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy

    International Nuclear Information System (INIS)

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-01-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct

  17. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy.

    Science.gov (United States)

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-04-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct.

  18. Intra-operative cerebrospinal fluid sampling versus post-operative lumbar puncture for detection of leptomeningeal disease in malignant paediatric brain tumours.

    Directory of Open Access Journals (Sweden)

    Sharon Y Y Low

    Full Text Available Leptomeningeal disease is a feared sequelae of malignant paediatric brain tumours. Current methods for its detection is the combined use of cranio-spinal MRI, and CSF cytology from a post-operative lumbar puncture. In this study, the authors hypothesize that CSF taken at the start of surgery, either from an external ventricular drain or neuroendoscope will have equal sensitivity for positive tumour cells, in comparison to lumbar puncture. Secondary hypotheses include positive correlation between CSF cytology and MRI findings of LMD. From a clinical perspective, the key aim of the study was for affected paediatric patients to avoid an additional procedure of a lumbar puncture, often performed under anaesthesia after neurosurgical intervention.This is single-institution, retrospective study of paediatric patients diagnosed with malignant brain tumours. Its main aim was to compare cytological data from CSF collected at the time of surgery versus data from an interval lumbar puncture. In addition, MRI imaging of the same cohort of patients was examined for leptomeningeal disease and corroborated against CSF tumour cytology findings.Thirty patients are recruited for this study. Data analysis demonstrates a statistically significant association between our intra-operative CSF and LP sampling. Furthermore, our results also show for significant correlation between evidence of leptomeningeal disease on MRI findings versus intra-operative CSF positivity for tumour cells.Although this is a retrospective study with a limited population, our data concurs with potential to avoid an additional procedure for the paediatric patient diagnosed with a malignant brain tumour.

  19. 3-Dimensional printing guide template assisted percutaneous vertebroplasty: Technical note.

    Science.gov (United States)

    Li, Jian; Lin, JiSheng; Yang, Yong; Xu, JunChuan; Fei, Qi

    2018-06-01

    Percutaneous vertebroplasty (PVP) is currently considered as an effective treatment for pain caused by acute osteoporotic vertebral compression fracture. Recently, puncture-related complications are increasingly reported. It's important to find a precise technique to reduce the puncture-related complications. We report a case and discussed the novel surgical technique with step-by-step operating procedures, to introduce the precise PVP assisted by a 3-dimensional printing guide template. Based on the preoperative CT scan and infrared scan data, a well-designed individual guide template could be established in a 3-dimensional reconstruction software and printed out by a 3-dimensional printer. In real operation, by matching the guide template to patient's back skin, cement needles' insertion orientation and depth were easily established. Only 14 times C-arm fluoroscopy with HDF mode (total exposure dose was 4.5 mSv) were required during the procedure. The operation took only 17 min. Cement distribution in the vertebral body was very good without any puncture-related complications. Pain was significantly relieved after surgery. In conclusion, the novel precise 3-dimensional printing guide template system may allow (1) comprehensive visualization of the fractured vertebral body and the individual surgical planning, (2) the perfect fitting between skin and guide template to ensure the puncture stability and accuracy, and (3) increased puncture precision and decreased puncture-related complications, surgical time and radiation exposure. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. The comparative study of CT guided and ultrasound guided percutaneous ethanol injection in the treatment of intra-abdominal cyst

    International Nuclear Information System (INIS)

    Li Heping; Yang Jianyong; Chen Wei; Zhuang Wenquan; Huang Yulian; Chen Jianye

    2005-01-01

    Objective: An comparative study of the interventional approach of CT guided and ultiasound guided percutaneous ethanol injection(PEI) in the treatment of intra-abdominal cyst. Methods: CT guided PEI was performed in the treatment of intra-abdominal cyst in 38 patients while ultrasound guided PEI was performed in 45 cases. Results: The puncture procedure of CT guided PEI was totally performed 83 times in treating 56 intra-abdominal cysts in 38 patients and CT guided PEI was unsuccessful in 6 patients. The puncture procedure of ultrasound guided PEI were performed 87 times in treating 71 intra-abdominal cysts in 55 patients and ultrasound guided PEI only failed only in 1 patient. Conclusion: Ultrasound guided PEI is superior to CT guided PEI in the treatment of intra-abdominal cyst. (authors)

  1. Lateral cervical puncture for cervical myelography

    International Nuclear Information System (INIS)

    Seol, Hae Young; Cha, Sang Hoon; Kim, Yoon Hwan; Suh, Won Hyuck

    1985-01-01

    Eleven cervical myelograms were performed by lateral cervical puncture using Metrizamide. So, following results were obtained: 1. Site of lateral cervical puncture; Posterior one third of bony cervical canal at C 1-2 level. 2. Advantages as compared with lumbar puncture for cervical myelograms; 1) Small amount of contrast media 2) Excellent image 3) Less position charge 4) Short time 5) Well visualization of superior margin of obstructive lesion in spinal canal 3. Cessation of lateral cervical puncture, when; 1) Pain during injection of contrast media 2) Localized collection of contrast media

  2. Lateral cervical puncture for cervical myelography

    Energy Technology Data Exchange (ETDEWEB)

    Seol, Hae Young; Cha, Sang Hoon; Kim, Yoon Hwan; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    1985-12-15

    Eleven cervical myelograms were performed by lateral cervical puncture using Metrizamide. So, following results were obtained: 1. Site of lateral cervical puncture; Posterior one third of bony cervical canal at C 1-2 level. 2. Advantages as compared with lumbar puncture for cervical myelograms; 1) Small amount of contrast media 2) Excellent image 3) Less position charge 4) Short time 5) Well visualization of superior margin of obstructive lesion in spinal canal 3. Cessation of lateral cervical puncture, when; 1) Pain during injection of contrast media 2) Localized collection of contrast media.

  3. Concomitant Intracranial and Lumbar Chronic Subdural Hematoma Treated by Fluoroscopic Guided Lumbar Puncture: A Case Report and Literature Review

    Science.gov (United States)

    ICHINOSE, Daisuke; TOCHIGI, Satoru; TANAKA, Toshihide; SUZUKI, Tomoya; TAKEI, Jun; HATANO, Keisuke; KAJIWARA, Ikki; MARUYAMA, Fumiaki; SAKAMOTO, Hiroki; HASEGAWA, Yuzuru; TANI, Satoshi; MURAYAMA, Yuichi

    2018-01-01

    A 40-year-old man presented with a severe headache, lower back pain, and lower abdominal pain 1 month after a head injury caused by falling. Computed tomography (CT) of the head demonstrated bilateral chronic subdural hematoma (CSDH) with a significant amount in the left frontoparietal region. At the same time, magnetic resonance imaging (MRI) of the lumbar spine also revealed CSDH from L2 to S1 level. A simple drainage for the intracranial CSDH on the left side was performed. Postoperatively, the headache was improved; however, the lower back and abdominal pain persisted. Aspiration of the liquefied spinal subdural hematoma was performed by a lumbar puncture under fluoroscopic guidance. The clinical symptoms were dramatically improved postoperatively. Concomitant intracranial and spinal CSDH is considerably rare so only 23 cases including the present case have been reported in the literature so far. The etiology and therapeutic strategy were discussed with a review of the literature. Therapeutic strategy is not established for these two concomitant lesions. Conservative follow-up was chosen for 14 cases, resulting in a favorable clinical outcome. Although surgical evacuation of lumbosacral CSDH was performed in seven cases, an alteration of cerebrospinal fluid (CSF) pressure following spinal surgery should be reminded because of the intracranial lesion. Since CSDH is well liquefied in both intracranial and spinal lesion, a less invasive approach is recommended not only for an intracranial lesion but also for spinal lesion. Fluoroscopic-guided lumbar puncture for lumbosacral CSDH following burr hole surgery for intracranial CSDH could be a recommended strategy. PMID:29479039

  4. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    International Nuclear Information System (INIS)

    Too, Chow Wei; Sayani, Raza; Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva; Teo, Terence K.

    2016-01-01

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  5. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    Energy Technology Data Exchange (ETDEWEB)

    Too, Chow Wei, E-mail: toochowwei@gmail.com [Singapore General Hospital (Singapore); Sayani, Raza [Aga Khan University Hospital (Pakistan); Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva [Singapore General Hospital (Singapore); Teo, Terence K. [Mount Elizabeth Novena Hospital (Singapore)

    2016-08-15

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  6. Retrograde vs. Antegrade Puncture for Infra-Inguinal Angioplasty

    International Nuclear Information System (INIS)

    Nice, C.; Timmons, G.; Bartholemew, P.; Uberoi, R.

    2003-01-01

    This study was done to compare antegrade punctures with a retrograde puncture technique for infrainguinal angioplasty. A group of 100 consecutive patients (71 men, 29 women) were randomized for antegrade puncture or retrograde puncture of the common femoral artery. Following retrograde puncture the guidewire was 'turned' and placed into the superficial femoral artery. The time for gaining access, screening time, radiation dose, patient height, weight and complications were recorded. All patients were reviewed the day after the procedure and within 3 months. Data from 46 patients (34 males and 12 females) in the retrograde group and 44 (28 males and 16 females) in the antegrade group were available for analysis. Mean procedure time,screening time, radiation dose, height and weight were 8.3 minutes(range 3-22), 2.1 minutes (0.3-6.5), 7950 mGy cm -2 (820-71250), 169 cm (149-204) and 79 kg (32-108) for retrograde puncture and 8 min (2-60), 0.7 min (0.0-3.2), 1069 mGycm -2 (0-15400), 169 cm (152-186) and 75 kg (39-125) for antegrade punctures, respectively. An average of 1.2 (1-2) punctures was required for retrograde and 1.75 (1-8) for antegrade. Seven small hematomas occurred with antegrade and three for retrograde puncture.Retrograde puncture is technically easier with a tendency to fewer complications but results in a higher radiation dose. This technique should be used in difficult patients at high risk of haematoma formation

  7. Three-dimensional C-arm CT-guided transjugular intrahepatic portosystemic shunt placement: Feasibility, technical success and procedural time

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik; Groezinger, Gerd; Maurer, Michael; Grosse, Ulrich; Horger, Marius; Nikolaou, Konstantin; Syha, Roland [University of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Lauer, Ulrich M. [University of Tuebingen, Internal Medicine I, Department of Gastroenterology, Hepatology and Infectious disease, Tuebingen (Germany)

    2016-12-15

    Establishment of transjugular intrahepatic portosystemic shunts (TIPS) constitutes a standard procedure in patients suffering from portal hypertension. The most difficult step in TIPS placement is blind puncture of the portal vein. This study aimed to evaluate three-dimensional mapping of portal vein branches and targeted puncture of the portal vein. Twelve consecutive patients suffering from refractory ascites by liver cirrhosis were included in this retrospective study to evaluate feasibility, technical success and procedural time of C-arm CT-targeted puncture of the portal vein. As a control, 22 patients receiving TIPS placement with fluoroscopy-guided blind puncture were included to compare procedural time. Technical success could be obtained in 100 % of the study group (targeted puncture) and in 95.5 % of the control group (blind puncture). Appropriate, three-dimensional C-arm CT-guided mapping of the portal vein branches could be achieved in all patients. The median number of punctures in the C-arm CT-guided study group was 2 ± 1.3 punctures. Procedural time was significantly lower in the study group (14.8 ± 8.2 min) compared to the control group (32.6 ± 22.7 min) (p = 0.02). C-arm CT-guided portal vein mapping is technically feasible and a promising tool for TIPS placement resulting in a significant reduction of procedural time. (orig.)

  8. The natural history of pedal puncture wounds in diabetics: a cross-sectional survey

    Directory of Open Access Journals (Sweden)

    East Jeffrey M

    2011-10-01

    Full Text Available Abstract Background Surgeons usually witness only the limb-threatening stages of infected, closed pedal puncture wounds in diabetics. Given that this catastrophic outcome often represents failure of conservative management of pre-infected wounds, some suggest consideration of invasive intervention (coring or laying-open for pre-infected wounds in hope of preventing contamination from evolving into infection, there being no evidence based guidelines. However, an invasive pre-emptive approach is only justifiable if the probability of progression to catastrophic infection is very high. Literature search revealed no prior studies on the natural history of closed pedal puncture wounds in diabetics. Methods A survey was conducted via an interviewer-administered questionnaire on 198 adult diabetics resident in the parish of St. James, Jamaica. The sample was selected using a purposive technique designed to mirror the social gradient and residential distribution of the target population and is twice the number needed to detect a prevalence of puncture wounds of 14% with a range of 7-21% in a random sample of the estimated adult diabetic population. Results The prevalence of a history of at least one closed pedal puncture wound since diagnosis of diabetes was 25.8% (CI; 19.6-31.9%. The only modifiable variable associated at the 5% level of significance with risk of pedal puncture wound, after adjustment by multivariable logistic regression, was site of interview/paying status, a variable substantially reflective of income more so than quality-of-care. Of 77 reported episodes of closed pedal puncture wound among 51 participants, 45.4% healed without medical intervention, 27.3% healed after non-surgical treatment by a doctor and 27.3% required surgical intervention ranging from debridement to below-knee amputation. Anesthetic foot (failure to feel the puncture and sole of the forefoot as site of puncture were the variables significantly associated with

  9. Unilateral transpedicular percutaneous vertebroplasty using puncture simulation

    International Nuclear Information System (INIS)

    Kobayashi, Ken; Takizawa, Kenji; Koyama, Masamichi; Yoshimatsu, Misako; Sakaino, Shinjiro; Nakajima, Yasuo

    2006-01-01

    The aim of this study was to improve the accuracy of puncture to the median vertebral body using the unilateral transpedicular approach on percutaneous vertebroplasty (PVP). We have developed and evaluated a simple puncture simulation method based on the puncture angle determined by preoperative computed tomography (CT). Two groups were evaluated. The first (group A) comprised 23 patients (34 vertebral bodies) who had undergone PYP without preoperative puncture simulation before May 2004, and the second group (group B) comprised 24 patients (39 vertebral bodies) who had undergone preoperative puncture simulation and PVP after May 2004. CT in the prone position was performed, and the puncture angle on CT (PAC) via the vertebral arch pedicle targeting the anterior one-third median site of the vertebral body was determined. Puncture was performed by targeting the isocenter established on a fluoroscopic monitor based on the PAC. Determinations were made of the success rate (SR) of the median puncture of the vertebral body, the effect of treatment using the visual analogue score, and the overall procedural time between groups A and B. The SR was 56% (19/34 vertebral bodies) in group A, and 97% (37/38 vertebral bodies), including only one vertebral body in which it was difficult to perform the unilateral approach on CT images, in group B, with the difference being significant by Student's t-test (P<0.001). Among patients with available follow-up data, the unipedicular and bipedicular approaches achieved adequate pain relief with mean decreases in pain severity of 5.1±2.6 and 5.9±2.8 respectively. No significant differences in the treatment effect between the two groups was observed (P=0.811). The overall procedure time per puncture was shorten for the simulation group (36.0 min) than for group A (73.1 min), as shown by regression analysis. The preoperative PAC determination for PVP under fluoroscopy increased the completion rate of PVP by the unilateral transpedicular

  10. Echocardiography-guided or "sided" pericardiocentesis.

    Science.gov (United States)

    Degirmencioglu, Aleks; Karakus, Gultekin; Güvenc, Tolga Sinan; Pinhan, Osman; Sipahi, Ilke; Akyol, Ahmet

    2013-10-01

    Echocardiography-guided pericardiocentesis is the first choice method for relieving cardiac tamponade, but the exact role of the echocardiography at the moment of the puncture is still controversial. In this report, detailed echocardiographic evaluation was performed in 21 consecutive patients with cardiac tamponade just before the pericardiocentesis. Appropriate needle position was determined according to the probe position using imaginary x, y, and z axes. Pericardiocentesis was performed successfully using this technique without simultaneous echocardiography and no complications were observed. We concluded that bedside echocardiography with detailed evaluation of the puncture site and angle is enough for pericardiocentesis instead of real time guiding. © 2013, Wiley Periodicals, Inc.

  11. Influence of repetitive finger puncturing on skin perfusion and capillary blood analysis in patients with diabetes mellitus

    NARCIS (Netherlands)

    de Graaff, J. C.; Hemmes, G. J.; Bruin, T.; Ubbink, D. T.; Michels, R. P.; Jacobs, M. J.; Sanders, G. T.

    1999-01-01

    Frequent puncturing of fingers to check blood glucose in patients with type 1 diabetes might alter skin perfusion and, hence, influence the representativeness of the blood sample. We investigated the influence of repetitive puncturing on skin microcirculatory perfusion using laser Doppler fluxmetry

  12. Changing the needle for lumbar punctures

    DEFF Research Database (Denmark)

    Engedal, Thorbjørn Søndergaard; Ording, H.; Vilholm, O. J.

    2015-01-01

    Objective: Post-dural puncture headache (PDPH) is a common complication of diagnostic lumbar punctures. Both a non-cutting needle design and the use of smaller size needles have been shown to greatly reduce the risk of PDPH. Nevertheless, larger cutting needles are still widely used. This study d...

  13. Development and psychometric evaluation of the arterial puncture self-efficacy scale.

    Science.gov (United States)

    Hernández-Padilla, José Manuel; Granero-Molina, José; Márquez-Hernández, Verónica V; Suthers, Fiona; Fernández-Sola, Cayetano

    2016-05-01

    Arterial puncture for arterial blood gases (ABG) analysis can be a risky, painful, difficult-to-perform procedure that is often insufficiently practised and generates stress and discomfort amongst patients and healthcare professionals. Self-efficacy is a key component in the acquisition of procedural skills. Therefore, professionals' self-efficacy in arterial puncture should be measured before attempting the procedure on real patients. To develop and psychometrically assess a self-efficacy scale in arterial puncture. An observational cross-sectional design was used in this study. Faculty of Education Sciences, Nursing and Physiotherapy in a higher education institution in the south of Spain. A convenience sample of 342 nursing students entered and completed the study. All participants met the following inclusion criteria: (1) ≥18years old and (2) enrolled in a nursing degree programme during the 2014/2015 academic year. Participants were 74% female (n=254) and their age ranged from 18 to 50, with a mean age of 21.74years (SD=5.14). The Arterial Puncture Self-Efficacy Scale (APSES) was developed and psychometrically tested. Reliability and content validity were studied. Predictive validity and concurrent validity assessed criterion validity. In addition, principal component analysis and known-group analysis evaluated construct validity. Principal component analysis revealed the two-subscale structure of the final 22-item version of the Arterial Puncture Self-Efficacy Scale (APSES). A total Cronbach's alpha coefficient of 0.97 showed its high reliability. The APSES' content validity index was excellent (S-CVI/Ave=0.95). Predictive and concurrent validity analysis demonstrated the good criterion validity of the tool. Supporting the APSES' sensitivity and specificity, known-groups analysis evidenced significant differences (pgood psychometric properties for measuring self-efficacy in arterial puncture for ABG analysis. Copyright © 2016 Elsevier Ltd. All rights

  14. Puncture Reduction in Percutaneous Transforaminal Endoscopic Discectomy with HE's Lumbar LOcation (HELLO System: A Cadaver Study.

    Directory of Open Access Journals (Sweden)

    Guoxin Fan

    Full Text Available Percutaneous transforaminal endoscopic discectomy (PTED usually requires numerous punctures under X-ray fluoroscopy. Repeated puncture will lead to more radiation exposure and reduce the beginners' confidence.This cadaver study aimed to investigate the efficacy of HE's Lumbar Location (HELLO system in puncture reduction of PTED.Cadaver study.Comparative groups.HELLO system consists of self-made surface locator and puncture locator. One senior surgeon conducted the puncture procedure of PTED on the left side of 20 cadavers at L4/L5 and L5/S1 level with the assistance of HELLO system (Group A. Additionally, the senior surgeon conducted the puncture procedure of PTED on the right side of the cadavers at L4/L5 and L5/S1 level with traditional methods (Group B. On the other hand, an inexperienced surgeon conducted the puncture procedure of PTED on the left side of the cadavers at L4/L5 and L5/S1 level with the assistance of our HELLO system (Group C.At L4/L5 level, there was significant difference in puncture times between Group A and Group B (P0.05. There was no difference in location time between Group A and Group B or Group A and Group C either at L4/L5 level or L5/S1 level (P>0.05.Small-sample preclinical study.HELLO system was effective in reducing puncture times, fluoroscopy time and radiation exposure, as well as the difficulty of learning PTED. (2015-RES-127.

  15. Simulation and training of lumbar punctures using haptic volume rendering and a 6DOF haptic device

    Science.gov (United States)

    Färber, Matthias; Heller, Julika; Handels, Heinz

    2007-03-01

    The lumbar puncture is performed by inserting a needle into the spinal chord of the patient to inject medicaments or to extract liquor. The training of this procedure is usually done on the patient guided by experienced supervisors. A virtual reality lumbar puncture simulator has been developed in order to minimize the training costs and the patient's risk. We use a haptic device with six degrees of freedom (6DOF) to feedback forces that resist needle insertion and rotation. An improved haptic volume rendering approach is used to calculate the forces. This approach makes use of label data of relevant structures like skin, bone, muscles or fat and original CT data that contributes information about image structures that can not be segmented. A real-time 3D visualization with optional stereo view shows the punctured region. 2D visualizations of orthogonal slices enable a detailed impression of the anatomical context. The input data consisting of CT and label data and surface models of relevant structures is defined in an XML file together with haptic rendering and visualization parameters. In a first evaluation the visible human male data has been used to generate a virtual training body. Several users with different medical experience tested the lumbar puncture trainer. The simulator gives a good haptic and visual impression of the needle insertion and the haptic volume rendering technique enables the feeling of unsegmented structures. Especially, the restriction of transversal needle movement together with rotation constraints enabled by the 6DOF device facilitate a realistic puncture simulation.

  16. Optimizing Residents' Performance of Lumbar Puncture

    DEFF Research Database (Denmark)

    Henriksen, Mikael Johannes Vuokko; Wienecke, Troels; Thagesen, Helle

    2018-01-01

    Background: Lumbar puncture is often associated with uncertainty and limited experience on the part of residents; therefore, preparatory interventions can be essential. There is growing interest in the potential benefit of videos over written text. However, little attention has been given...... to whether the design of the videos impacts on subsequent performance. Objective: To investigate the effect of different preparatory interventions on learner performance and self-confidence regarding lumbar puncture (LP). Design: Randomized controlled trial in which participants were randomly assigned to one...... of three interventions as preparation for performing lumbar puncture: 1) goal- and learner-centered video (GLV) presenting procedure-specific process goals and learner-centered information; 2) traditional video (TV) providing expert-driven content, but no process goals; and 3) written text (WT...

  17. Vapocoolant Spray Effectiveness on Arterial Puncture Pain: A Randomized Controlled Clinical Trial

    Directory of Open Access Journals (Sweden)

    Shervin Farahmand

    2017-02-01

    Full Text Available Arterial blood gas (ABG sampling is a painful procedure with no perfect technique for quelling the discomfort. An ideal local anesthesia should be rapid, easy to learn, inexpensive, and noninvasive. This study was aimed to compare pain levels from ABG sampling performed with vapocoolant spray in comparison to placebo. We hypothesized that pretreatment with the vapocoolant would reduce the pain of arterial puncture by at least 1 point on a 10 point verbal numeric scale. We have evaluated the effectiveness of a vapocoolant spray in achieving satisfactory pain control in patients undergoing ABG sampling in this randomized placebo controlled trial. Eighty patients were randomized to 2 groups: group A, who received vapocoolant spray, and group B, who received water spray as placebo (Control group. Puncture and spray application pain was assessed with numerical rating scale (0, the absence of pain; 10, greatest imaginable pain and number of attempts was recorded. The pain score during ABG sampling was not lower in group A compared with group B significantly (4.78±1.761 vs. 4.90±1.837; P:0.945. This study showed that while the spray exerts more application pain, the number of attempts required for ABG sampling was not significantly lower in group A compared with group B (1.38±0.54 vs. 1.53±0.68; P=0.372. Vapocoolant spray was not effective in ABG pain reduction, had milder application pain compared to placebo (P<0.05, but did not reduce sampling attempts. At present, this spray cannot be recommended for arterial puncture anesthesia, and further study on different timing is necessary.

  18. Application of CT-guided percutaneous thyroid biopsy in basic study of interventional therapy for Graves disease

    International Nuclear Information System (INIS)

    Yi Genfa; Zhao Wei; Hu Jihong; Jin Cangzheng; Yang Huiying

    2007-01-01

    Objective: To evaluate the value of application of CT-guided percutaneous thyroid biopsy in basic study of interventional treatment for Graves disease. Methods: Fifteen patients of hyperthyroidism caused by Graves' disease had been undertaken transcathter arterial embolizsation with PVA micropheres including 52 core needle biopsy(CNB)of pre-or post-interventional procedure. All procedures were divided into 2 groups according to the size of the thyroid enlargement: (1) II degree enlargement (n=19)under palpation puncture. (2) No enlargement or under II degree enlargement (n=33)with palpation and CT-guided puncture. Results: In group (1), 17 of the 19 procedures with palpation puncture were succeeded, reaching a successful rate of 89.5%. For group (2), the successful rate of CT-guided puncture was 91.7%. The difference between the successful rate of two groups showed statistical significance (P<0.05). No complication occurred during procedures in all cases. Conclusions: CT-guided thyroid core needle biopsy is an accurate, safe and high successful procedure providing the basic study for post-interventional treatment of Graves disease. (authors)

  19. Aerosol can puncture device operational test plan

    International Nuclear Information System (INIS)

    Leist, K.J.

    1994-01-01

    Puncturing of aerosol cans is performed in the Waste Receiving and Processing Facility Module 1 (WRAP 1) process as a requirement of the waste disposal acceptance criteria for both transuranic (TRU) waste and low-level waste (LLW). These cans have contained such things as paints, lubricating oils, paint removers, insecticides, and cleaning supplies which were used in radioactive facilities. Due to Westinghouse Hanford Company (WHC) Fire Protection concerns of the baseline system's fire/explosion proof characteristics, a study was undertaken to compare the baseline system's design to commercially available puncturing devices. While the study found no areas which might indicate a risk of fire or explosion, WHC Fire Protection determined that the puncturing system must have a demonstrated record of safe operation. This could be obtained either by testing the baseline design by an independent laboratory, or by substituting a commercially available device. As a result of these efforts, the commercially available Aerosolv can puncturing device was chosen to replace the baseline design. Two concerns were raised with the system. Premature blinding of the coalescing/carbon filter, due to its proximity to the puncture and draining operation; and overpressurization of the collection bottle due to its small volume and by blinding of the filter assembly. As a result of these concerns, testing was deemed necessary. The objective of this report is to outline test procedures for the Aerosolv

  20. Puncture Reduction in Percutaneous Transforaminal Endoscopic Discectomy with HE's Lumbar LOcation (HELLO) System: A Cadaver Study.

    Science.gov (United States)

    Fan, Guoxin; Guan, Xiaofei; Sun, Qi; Hu, Annan; Zhu, Yanjie; Gu, Guangfei; Zhang, Hailong; He, Shisheng

    2015-01-01

    Percutaneous transforaminal endoscopic discectomy (PTED) usually requires numerous punctures under X-ray fluoroscopy. Repeated puncture will lead to more radiation exposure and reduce the beginners' confidence. This cadaver study aimed to investigate the efficacy of HE's Lumbar Location (HELLO) system in puncture reduction of PTED. Cadaver study. Comparative groups. HELLO system consists of self-made surface locator and puncture locator. One senior surgeon conducted the puncture procedure of PTED on the left side of 20 cadavers at L4/L5 and L5/S1 level with the assistance of HELLO system (Group A). Additionally, the senior surgeon conducted the puncture procedure of PTED on the right side of the cadavers at L4/L5 and L5/S1 level with traditional methods (Group B). On the other hand, an inexperienced surgeon conducted the puncture procedure of PTED on the left side of the cadavers at L4/L5 and L5/S1 level with the assistance of our HELLO system (Group C). At L4/L5 level, there was significant difference in puncture times between Group A and Group B (PHELLO system reduced 39%-45% radiation dosage when comparing Group A and Group B, but there was no significant difference in radiation exposure between Group A and Group C whatever at L4/L5 level or L5/S1 level (P>0.05). There was no difference in location time between Group A and Group B or Group A and Group C either at L4/L5 level or L5/S1 level (P>0.05). Small-sample preclinical study. HELLO system was effective in reducing puncture times, fluoroscopy time and radiation exposure, as well as the difficulty of learning PTED. (2015-RES-127).

  1. Maass Cusp Forms on Singly Punctured Two-Torus

    International Nuclear Information System (INIS)

    Siddig, Abubaker Ahmed Mohamed; Shah, Nurisya Mohd; Zainuddin, Hishamuddin

    2009-01-01

    Quantum mechanical systems on punctured surfaces modeled by hyperbolic spaces can play an interesting role in exploring quantum chaos and in studying behaviour of future quantum nano-devices. The case of singly-punctured two-torus, for example, has been well-studied in the literature particularly for its scattering states. However, the bound states on the punctured torus given by Maass cusp forms are lesser known. In this note, we report on the algorithm of numerically computing these functions and we present ten lower-lying eigenvalues for each odd and even Maass cusp forms.

  2. Accuracy and feasibility of frameless stereotactic and robot-assisted CT-based puncture in interventional radiology. A comparative phantom study

    International Nuclear Information System (INIS)

    Stoffner, R.; Widmann, G.; Bale, R.; Augschoell, C.; Boehler, D.

    2009-01-01

    Purpose: To compare the accuracy of frameless stereotactic and robot-assisted puncture in vitro based on computed tomography (CT) imaging with a slice thickness of 1, 3, and 5 mm. Materials and Methods: 300 punctures were carried out with help of the Atlas aiming device guided by the optical navigation system Stealth Station TREONplus and 150 punctures were guided by the robotic assistance system Innomotion. Conically shaped rods were punctured with Kirschner wires. The accuracy was evaluated on the basis of control CTs by measuring the Euclidean distance between the wire tip and target and the normal distance between the target and wire. Results: With the Stealth Station a mean Euclidean distance of 1.94±0.912, 2.2±1.136, and 2.74±1.166 mm at a slice thickness of 1, 3 and 5 mm, respectively, was reached. The mean normal distance was 1.64±0.919, 1.84±1.189, and 2.48±1.196 mm, respectively. The Innomotion system resulted in a mean Euclidean distance of 1.69±0.772, 1.91±0.673, and 2.30±0.881 mm, respectively, while the mean normal distance was (1.42±0.78), 1.60±0.733, and 1.98±1.002 mm, respectively. A statistical significance between accuracies with both systems with 1 mm and 3 mm slices could not be detected (p > 0.05). At a slice thickness of 5 mm, the robot was significantly more accurate, but not as accurate as when using thinner slices (p < 0.05). The procedure time is longer for the Innomotion system (∝30 vs. ∝18 min), and the practicability is higher with the Stealth Station. (orig.)

  3. CT guided interventional therapy for hypertensive cerebral hemorrhage

    International Nuclear Information System (INIS)

    Lin Bo; Duan Bing

    2009-01-01

    Objective: To discuss the curative effect of CT-guided puncture and drainage in treating hypertensive cerebral hemorrhage. Methods: Adjusting the suitable point and direction of puncture according to the form and size of the haematoma and patient's status, the haematoma was eliminated by minimally invasive puncture and drainage guided under CT layer image in 40 cases of hypertensive cerebral hemorrhage. Results: Modality rate of treatment group was 12.5% (5/40), and is much lower than control group, which was 45% (13/30) (P<0.01). When asscess the Activities of Daily Living (ADL) after 6 months follow-up, the ADL1-ADL3 scale in treatment group was 27 cases (70%), and was much higher than that in control group, which was 29.4% (5/17), (P < 0.05). Conclusion: Minimal invasive therapy of cerebral hemorrhage has great superiority in elimination most part of the hematoma such as simple, accurate location, low cost, safe and effective, and is worthy of recommendation clinically. (authors)

  4. Clinical Feasibility and Usefulness of CT Fluoroscopy-Guided Percutaneous Transhepatic Biliary Drainage in Emergency Patients with Acute Obstructive Cholangitis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hyung [Sam Anyang Hospital, Anyang (Korea, Republic of)

    2009-04-15

    To evaluate the feasibility of CT fluoroscopy (CTF)-guided percutaneous transhepatic biliary drainage (PTBD) in emergency patients with acute obstructive cholangitis. The study included 28 patients admitted to the emergency center due to obstructive jaundice and found to require urgent biliary drainage, as well as judged to have a suitable peripheral bile duct for a CTF-guided puncture (at least 4 mm in width). Prior to the CTF-guided puncture, a CT scan was performed to evaluate bile duct dilatation and the underlying causes of biliary obstruction. If the patient was judged to be a suitable candidate, a CTF-guided PTBD was performed in the same CT unit without additional fluoroscopic guidance. Technical feasibility of the procedure was investigated with the evaluation of overall success rate and causes of failure. A hepatic puncture was attempted at the left lobe in 23 patients and right lobe in five patients. The procedure was successful in 24 of 28 patients (86%) Successful biliary puncture was achieved on the first attempt in 16 patients, the second attempt in five patients, and the third attempt in three patients. The causes of failure included guide wire twisting in one patient, biliary puncture failure in two patients, and poor visualization of the guide wire in one patient. There were no significant procedure-related complication. The CTF-guided PTBD is technically feasible and highly successful in patients judged to have a suitable indication. Moreover, although the procedure is unfamiliar and inconvenient to interventionalists, it has economical advantages in that it saves time and manpower. We believe this method can be used in the emergency patients requiring urgent biliary drainage as an alternative for the fluoroscopy-guided PTBD.

  5. Higher-dimensional puncture initial data

    International Nuclear Information System (INIS)

    Zilhao, Miguel; Ansorg, Marcus; Cardoso, Vitor; Gualtieri, Leonardo; Herdeiro, Carlos; Sperhake, Ulrich; Witek, Helvi

    2011-01-01

    We calculate puncture initial data, corresponding to single and binary black holes with linear momenta, which solve the constraint equations of D-dimensional vacuum gravity. The data are generated by a modification of the pseudospectral code presented in [M. Ansorg, B. Bruegmann, and W. Tichy, Phys. Rev. D 70, 064011 (2004).] and made available as the TwoPunctures thorn inside the Cactus computational toolkit. As examples, we exhibit convergence plots, the violation of the Hamiltonian constraint as well as the initial data for D=4,5,6,7. These initial data are the starting point to perform high-energy collisions of black holes in D dimensions.

  6. Arterial puncture using insulin needle is less painful than with standard needle: a randomized crossover study.

    Science.gov (United States)

    Ibrahim, Irwani; Yau, Ying Wei; Ong, Lizhen; Chan, Yiong Huak; Kuan, Win Sen

    2015-03-01

    Arterial punctures are important procedures performed by emergency physicians in the assessment of ill patients. However, arterial punctures are painful and can create anxiety and needle phobia in patients. The pain score of radial arterial punctures were compared between the insulin needle and the standard 23-gauge hypodermic needle. In a randomized controlled crossover design, healthy volunteers were recruited to undergo bilateral radial arterial punctures. They were assigned to receive either the insulin or the standard needle as the first puncture, using blocked randomization. The primary outcome was the pain score measured on a 100-mm visual analogue scale (VAS) for pain, and secondary outcomes were rate of hemolysis, mean potassium values, and procedural complications immediately and 24 hours postprocedure. Fifty healthy volunteers were included in the study. The mean (±standard deviation) VAS score in punctures with the insulin needle was lower than the standard needle (23 ± 22 mm vs. 39 ± 24 mm; mean difference = -15 mm; 95% confidence interval = -22 mm to -7 mm; p standard needle (31.3% vs. 11.6%, p = 0.035; and 4.6 ±0.7 mmol/L vs. 4.2 ±0.5 mmol/L, p = 0.002). Procedural complications were lower in punctures with the insulin needle both immediately postprocedure (0% vs. 24%; p standard needles. However, due to the higher rate of hemolysis, its use should be limited to conditions that do not require a concurrent potassium value in the same blood sample. © 2015 by the Society for Academic Emergency Medicine.

  7. Punctures for theories of class S{sub Γ}

    Energy Technology Data Exchange (ETDEWEB)

    Heckman, Jonathan J. [Department of Physics, University of North Carolina,Chapel Hill, NC 27599 (United States); Jefferson, Patrick; Rudelius, Tom; Vafa, Cumrun [Jefferson Physical Laboratory, Harvard University,Cambridge, MA 02138 (United States)

    2017-03-31

    With the aim of understanding compactifications of 6D superconformal field theories to four dimensions, we study punctures for theories of class S{sub Γ}. The class S{sub Γ} theories arise from M5-branes probing ℂ{sup 2}/Γ, an ADE singularity. The resulting 4D theories descend from compactification on Riemann surfaces decorated with punctures. We show that for class S{sub Γ} theories, a puncture is specified by singular boundary conditions for fields in the 5D quiver gauge theory obtained from compactification of the 6D theory on a cylinder geometry. We determine general boundary conditions and study in detail solutions with first order poles. This yields a generalization of the Nahm pole data present for 1/2 BPS punctures for theories of class S. Focusing on specific algebraic structures, we show how the standard discussion of nilpotent orbits and its connection to representations of su(2) generalizes in this broader context.

  8. Relativistic hydrodynamics in the presence of puncture black holes

    International Nuclear Information System (INIS)

    Faber, Joshua A.; Etienne, Zachariah B.; Shapiro, Stuart L.; Taniguchi, Keisuke; Baumgarte, Thomas W.

    2007-01-01

    Many of the recent numerical simulations of binary black holes in vacuum adopt the moving puncture approach. This successful approach avoids the need to impose numerical excision of the black hole interior and is easy to implement. Here we wish to explore how well the same approach can be applied to moving black hole punctures in the presence of relativistic hydrodynamic matter. First, we evolve single black hole punctures in vacuum to calibrate our Baumgarte-Shapiro-Shibata-Nakamura implementation and to confirm that the numerical solution for the exterior spacetime is invariant to any junk (i.e., constraint-violating) initial data employed in the black hole interior. Then we focus on relativistic Bondi accretion onto a moving puncture Schwarzschild black hole as a numerical test bed for our high-resolution shock-capturing relativistic hydrodynamics scheme. We find that the hydrodynamical equations can be evolved successfully in the interior without imposing numerical excision. These results help motivate the adoption of the moving puncture approach to treat the binary black hole-neutron star problem using conformal thin-sandwich initial data

  9. Puncture Wounds: First Aid

    Science.gov (United States)

    ... Skin problems. In: American Medical Association Handbook of First Aid and Emergency Care. New York, N.Y.: Random House; 2009. Jan. 12, 2018 Original article: http://www.mayoclinic.org/first-aid/first-aid-puncture-wounds/basics/ART-20056665 . Mayo ...

  10. Inexpensive homemade models for ultrasound-guided vein cannulation training.

    Science.gov (United States)

    Di Domenico, Stefano; Santori, Gregorio; Porcile, Elisa; Licausi, Martina; Centanaro, Monica; Valente, Umberto

    2007-11-01

    To test the hypothesis that low-cost homemade models may be used to acquire the basic skills for ultrasound-guided central vein puncture. Training study. University transplantation department. Training was performed using three different homemade models (A, B, and C). Segments of a common rubber tourniquet (V1) and Silastic tube (V2) were used to simulate vessels within agar-based models. Overall cost for each model was less than 5 euro (US$7). For each test (test I, A-V1; II, A-V2; III, B-V1; IV, C-V2), the number of punctures and attempts needed to locate the needle inside the lumen were recorded. Each test was considered completed when participants punctured the vessels at the first attempt for three consecutive times. In test I, the mean number of punctures and attempts were 3.85 +/- 1.26 and 4.95 +/- 3.05; in test II, 4.60 +/- 1.14 and 6.30 +/- 2.51; in test III, 4.80 +/- 1.06 and 4.65 +/- 2.21; and in test IV, 4.45 +/- 1.23 and 6.05 +/- 2.92, respectively. For each test, no statistical difference was found by comparison of number of punctures and attempts for anesthesiologists versus nonanesthesiologists, men versus women, or previous experience versus no experience with central vein cannulation (CVC). Video game users obtained better results than did nonusers in test I (punctures, P = 0.033; attempts, P = 0.038), test II (punctures, P = 0.052; attempts, P = 0.011), and test IV (punctures, P = 0.001; attempts, P = 0.003). A posttraining questionnaire showed favorable opinions about the clarity of the instructions, aptness of the models, and adequacy of the training. In our operative unit, the use of ultrasound guidance for CVC increased from 2% to 23% in the first month after training. Low-cost homemade models are useful in acquiring basic coordination skills for ultrasound-guided CVC.

  11. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus; Liebl, Martin [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany); Stillfried, Saskia Freifrau von [University Hospital RWTH Aachen, Department of Pathology (Germany); Kuhl, Christiane; Bruners, Philipp; Isfort, Peter [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

  12. Lumbar puncture in patients using anticoagulants and antiplatelet agents

    Directory of Open Access Journals (Sweden)

    Renan Domingues

    2016-08-01

    Full Text Available ABSTRACT The use of anticoagulants and antiplatelet agents has largely increased. Diagnostic lumbar puncture in patients taking these drugs represents a challenge considering the opposing risks of bleeding and thrombotic complications. To date there are no controlled trials, specific guidelines, nor clear recommendations in this area. In the present review we make some recommendations about lumbar puncture in patients using these drugs. Our recommendations take into consideration the pharmacology of these drugs, the thrombotic risk according to the underlying disease, and the urgency in cerebrospinal fluid analysis. Evaluating such information and a rigorous monitoring of neurological symptoms after lumbar puncture are crucial to minimize the risk of hemorrhage associated neurological deficits. An individualized patient decision-making and an effective communication between the assistant physician and the responsible for conducting the lumbar puncture are essential to minimize potential risks.

  13. Prestrain-induced Reduction in Skin Tissue Puncture Force of Microneedle

    International Nuclear Information System (INIS)

    Kim, Jonghun; Park, Sungmin; Nam, Gyungmok; Yoon, Sang-Hee

    2016-01-01

    Despite all the recent advances in biodegradable material-based microneedles, the bending and failure (especially buckling) of a biodegradable microneedle during skin tissue insertion remains a major technical hurdle for its large-scale commercialization. A reduction in skin tissue puncture force during microneedle insertion remains an essential issue in successfully developing a biodegradable microneedle. Here, we consider uniaxial and equibiaxial prestrains applied to a skin tissue as mechanophysical stimuli that can reduce the skin tissue puncture force, and investigate the effect of prestrain on the changes in skin tissue puncture force. For a porcine skin tissue similar to that of humans, the skin tissue puncture force of a flat-end microneedle is measured with a z-axis stage equipped with a load cell, which provides a force-time curve during microneedle insertion. The findings of this study lead to a quantitative characterization of the relationship between prestrain and the skin tissue puncture force

  14. Prestrain-induced Reduction in Skin Tissue Puncture Force of Microneedle

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jonghun; Park, Sungmin; Nam, Gyungmok; Yoon, Sang-Hee [Inha Univ., Incheon (Korea, Republic of)

    2016-10-15

    Despite all the recent advances in biodegradable material-based microneedles, the bending and failure (especially buckling) of a biodegradable microneedle during skin tissue insertion remains a major technical hurdle for its large-scale commercialization. A reduction in skin tissue puncture force during microneedle insertion remains an essential issue in successfully developing a biodegradable microneedle. Here, we consider uniaxial and equibiaxial prestrains applied to a skin tissue as mechanophysical stimuli that can reduce the skin tissue puncture force, and investigate the effect of prestrain on the changes in skin tissue puncture force. For a porcine skin tissue similar to that of humans, the skin tissue puncture force of a flat-end microneedle is measured with a z-axis stage equipped with a load cell, which provides a force-time curve during microneedle insertion. The findings of this study lead to a quantitative characterization of the relationship between prestrain and the skin tissue puncture force.

  15. Ultrasound-guided percutaneous transhepatic biliary drainage: Experiences in 146 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jai Keun [Sohwa Children' s Hospital, Seoul(Korea, Republic of); Yu, Jeong Sik; Kim, Ki Whang; Chung, Soo Yoon; Jeong, Mi Gyoung [Yonsei University College of Medicine, Seoul (Korea, Republic of); Choi, Deuk Lin; Kwon, Gui Hyang; Lee, Hae Kyung [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1999-03-15

    Percutaneous biliary drainage is an important technique for palliative therapy of obstructive biliary disease and diagnostic information. The purpose of this study is to review and evaluate the experiences of ultrasound-guided percutaneous transhepatic biliary drainage. Ultrasound-guided percutaneous transhepatic biliary drainage was performed on 146 occasions in 134 patients. The causes of biliary obstruction were: benign diseases (19 cases, 14.2%) such as bile duct stones or stricture, cholangiocarcinoma (37 cases, 27.6%), pancreatic carcinoma (35 cases, 26.1%), metastasis (22 cases, 16.5%), gall bladder cancer (14 cases, 10.4%), ampulla of Vater cancer (4 cases, 3.0%), hepatocellular carcinoma (3 cases, 2.2%). Retrospectively reviewing medical records, we found out frequency of external or external/internal biliary drainages, puncture of left or right hepatic duct, and presence of bileinfection. Ultrasound-guided percutaneous transhepatic biliary drainage was compared with conventional biliary drainage of previous reports on the basis of frequency of complications. External (124 procedures, 84.9%) and external/internal biliary drainage (22 procedures, 15.1%) were carried out by puncture of dilated right (59.6%) or left (40.4%) intrahepatic duct. Sixty-nine complications occurred in 47 patients. Catheter related complications (33/69, 47.8%) were most common: catheter dislodgement (17/69, 24.6%), malfunction (9/69, 13.1%), leakage (7/69, 10.1%). Other minor complications such as simple fever (16/69, 23.2%), cholangitis (7/69, 10.1%), hemobilia (4/69, 5.8%), biloma (2/69, 2.9%) and wound infection (1/69, 1.5%) occurred. Major complications including sepsis (4/69, 5.8%) and bile peritonitis (2/69, 2.9%) were also noted. Puncture-related complications such as hemobilia, biloma and bile peritonitis occurred in 8 cases (5.5%). Comparing with conventional X-ray guided drainage, ultrasound-guided percutaneous transhepatic biliary drainage is a safe procedure for

  16. Ultrasound-guided antegrade pyelography of renal transplants

    International Nuclear Information System (INIS)

    Wernecke, K.; Heckemann, R.; Rehwald, U.; Ringert, R.H.; Essen Univ.

    1983-01-01

    The indications for, and technique of, ultrasound-guided antegrade pyelography of renal transplants are illustrated by eight patients. Because of the detailed anatomical information which the antegrade method provides, it is superior to other diagnostic methods for the investigation of ureteric obstruction or fistulae. The severity of renal pelvis dilatation as shown by sonography must not be taken as a criterian for the grade of obstruction, since transplants may show dilated collecting systems, even in the absence of obstruction. In our view, real time sonography with a suitable probe provides the best means of achieving successful puncture of the renal pelvis. The combination of ultrasound-guided puncture and radiological contrast examination of the ureter is the best diagnostic method available and lead, in all eight cases, to immediate and definitive treatment. (orig.)

  17. Fuel rod puncturing and fission gas monitoring system examination techniques

    International Nuclear Information System (INIS)

    Song, Woong Sup

    1999-02-01

    Fission gas products accumulated in irradiated fuel rod is 1-2 cm 3 in CANDU and 40-50 cm 3 in PWR fuel rod. Fuel rod puncturing and fission gas monitoring system can be used for both CANDU and PWR fuel rod. This system comprises puncturing device located at in cell part and monitoring device located at out cell part. The system has computerized 9 modes and can calculate both void volume and mass volume only single puncturing. This report describes techniques and procedure for operating fuel rod puncturing and gas monitoring system which can be play an important role in successful operation of the devices. Results obtained from the analysis can give more influence over design for fuel rods. (Author). 6 refs., 9 figs

  18. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method.

    Science.gov (United States)

    Kakizawa, Hideaki; Toyota, Naoyuki; Hieda, Masashi; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Oda, Miyo; Ito, Katsuhide

    2010-09-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: "none", "mild", "moderate" and "severe". The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p < 0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax.

  19. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method

    International Nuclear Information System (INIS)

    Kakizawa, Hideaki; Hieda, Masashi; Oda, Miyo; Toyota, Naoyuki; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Ito, Katsuhide

    2010-01-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: 'none', 'mild', 'moderate' and 'severe'. The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p<0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax. (author)

  20. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid Nodules: is it Necessary to Use Local Anesthesia for the Application of One Needle Puncture?

    International Nuclear Information System (INIS)

    Kim, Dong Wook; Rho, Myung Ho; Kim, Ki Nam

    2009-01-01

    This study was designed to evaluate the difference in the degree of patient pain for an ultrasound-guided fine-needle aspiration biopsy (USFNAB) of a thyroid nodule with one needle puncture with and without local anesthesia. A total of 50 patients participated in the study. We examined prospective patients who would undergo US-FNABs of two thyroid nodules (larger than 10 mm maximum diameter), which were located in separate thyroid lobes. For one of these thyroid nodules, US-FNAB was performed following the administration of local anesthesia; for the other nodule, no anesthesia was administered. The application of anesthesia was alternatively administered between patients (either prior to the first US-FNAB procedure or prior to the second procedure). For all patients, the degree of pain during and after each US-guided FNAB was evaluated according to a 4-category verbal rating scale (VRS), an 11-point numeric rating scale (NRS) and a 100-mm visual analogue scale (VAS). The mean maximum diameters of thyroid nodules examined by US-FNAB with the use of local anesthesia and with no local anesthesia were 13.6 mm and 13.0 mm, respectively. There was no significant difference in nodule size (p > 0.05) between two groups. For the VRS, there were 27 patients with a higher pain score when local anesthesia was used and four patients with a higher pain score when no local anesthesia was administered. Nineteen patients had equivalent pain score for both treatments. This finding was statistically significant (p < 0.001). For the NRS, there were 33 patients with a higher pain score when local anesthesia was used and 10 patients with a higher pain score when no local anesthesia was administered. Seven patients had an equivalent pain score for each treatment. This finding was statistically significant (p < 0.001). For the VAS, there were 35 patients with a higher pain score when local anesthesia was used and 11 patients with a higher pain score where no local anesthesia was

  1. The Tension and Puncture Properties of HDPE Geomembrane under the Corrosion of Leachate.

    Science.gov (United States)

    Xue, Qiang; Zhang, Qian; Li, Zhen-Ze; Xiao, Kai

    2013-09-17

    To investigate the gradual failure of high-density polyethylene (HDPE) geomembrane as a result of long-term corrosion, four dynamic corrosion tests were conducted at different temperatures and durations. By combining tension and puncture tests, we systematically studied the variation law of tension and puncture properties of the HDPE geomembrane under different corrosion conditions. Results showed that tension and puncture failure of the HDPE geomembrane was progressive, and tensile strength in the longitudinal grain direction was evidently better than that in the transverse direction. Punctures appeared shortly after puncture force reached the puncture strength. The tensile strength of geomembrane was in inversely proportional to the corrosion time, and the impact of corrosion was more obvious in the longitudinal direction than transverse direction. As corrosion time increased, puncture strength decreased and corresponding deformation increased. As with corrosion time, the increase of corrosion temperature induced the decrease of geomembrane tensile strength. Tensile and puncture strength were extremely sensitive to temperature. Overall, residual strength had a negative correlation with corrosion time or temperature. Elongation variation increased initially and then decreased with the increase in temperature. However, it did not show significant law with corrosion time. The reduction in puncture strength and the increase in puncture deformation had positive correlations with corrosion time or temperature. The geomembrane softened under corrosion condition. The conclusion may be applicable to the proper designing of the HDPE geomembrane in landfill barrier system.

  2. The reasons for delay lumbar puncture

    Directory of Open Access Journals (Sweden)

    MH. Lotfi

    2017-04-01

    Full Text Available Early diagnosis of meningitis and encephalitis and prompt initiation of appropriate therapy is vital and any delay will lead to high mortality and serious and permanent morbidity. The main purpose of this study was to evaluate the management of 220 patients with suspected central nervous system (CNS infections (meningitis and encephalitis to determine the percentage of patients’ suspected CNS infection undergo lumbar puncture in acceptable time (in accordance with conventional algorithms. In this descriptive study, patients with suspected CNS infections admitted to Bu-Ali and Qods hospitals, in the period July 2013 to December 2015 were studied. Information of 220 patients was collected. Continuous variables were summarized as means ± standard deviation and categorical variables as frequencies and percentages. Lumbar puncture (LP in patients was delayed in 200 cases (91%. Most common causes of delay in performing LP were prolongation of the process of determining patient needs to puncture, satisfying patients, CT scan delay and the delay in allowing LP by neurologist. In this study, delaying LP rate was higher than other studies. It seems certain pattern in assistants’ visits for counseling. CT requests and neurologic consultation before LP performed for all adult patients.

  3. Cerebrospinal fluid loss at lumbar puncture for caesarean section ...

    African Journals Online (AJOL)

    Background Post dural puncture headache (PDPH) is an unpleasant complication of spinal anaesthesia. Several studies have attempted explanation of its pathophysiology. A widely held view is that it results from loss of cerebrospinal fluid volume resulting from leak following a hole left in the dura after the puncture.

  4. A new device of CT-targeted percutaneous punctures

    International Nuclear Information System (INIS)

    Ozdoba, C.

    1990-01-01

    This paper reports on a device for CT-targeted percutaneous punctures. After extensive phantom studies, punctures of vertebral disk space (diskography/nucleotomy) and orbit retrobulbar anesthesia/biopsy were performed in 15 patients. The new device is easy to mount on the CT scanner and does not require additional devices affixed to the patient. Its design and construction permit exact calculation of needle angle and depth, even when the gantry is tilted. Percutaneous biopsies can be performed in approximately 40 minutes. The device is accurate within ±0.5 mm, thereby allowing puncture of even small lesions deep in the orbital cone. Retrobulbar anesthesia can be performed safely in patients with a long myopic bulbus; in nucleotomy, instant control of the instrument's position within the disk space is possible

  5. Complications of the lateral C1-C2 puncture myelography for cervical spinal canal

    International Nuclear Information System (INIS)

    Mihale, J.; Traubner, P.

    1998-01-01

    This reviewed the complications of 106 patients of the lateral C1-C2 puncture myelography for cervical spinal canal and cervical spinal cord disorders. Spinal cord puncture and contrast injection, puncture between the occiput and C1, and blood vessel puncture were the main complications. These principally depended on the misdirection of the X ray beam. For preventing major arterial puncture determined the pathway of the vertebral arteries and incidence of anomaly. (authors)

  6. Rotational Angiography Based Three-Dimensional Left Atrial Reconstruction: A New Approach for Transseptal Puncture.

    Science.gov (United States)

    Koektuerk, Buelent; Yorgun, Hikmet; Koektuerk, Oezlem; Turan, Cem H; Gorr, Eduard; Horlitz, Marc; Turan, Ramazan G

    2016-02-01

    Rotational angiography is a well-known method for the three-dimensional (3-D) reconstruction of left atrium and pulmonary veins during left-sided atrial arrhythmia ablation procedures. In our study, we aimed to review our experience in transseptal puncture (TSP) using 3-D rotational angiography. We included a total of 271 patients who underwent atrial fibrillation ablation using cryoballoon. Rotational angiography was performed to get the three-dimensional left atrial and pulmonary vein reconstructions using cardiac C-arm computed tomography. The image reconstruction was made using the DynaCT Cardiac software (Siemens, Erlangen, Germany). The mean age of the study population was 61 ± 10 years. The indications for left atrial arrhythmia ablation were paroxysmal AF in 140 patients (52%) and persistent AF patients in 131 (48%) patients. The success rate of TSP using only rotational guidance was (264/271 patients, 97.4%). In the remaining seven patients, transesophageal guidance was used after the initial attempt due to thick interatrial septum in five patients and difficult TSP due to abnormal anatomy and mild pericardial effusion in the remaining two patients. Mean fluoroscopy dosage of the rotational angiography was 4896.4 ± 825.3 μGym(2). The mean time beginning from femoral vein puncture to TSP was 12.3 ± 5.5 min. TSP guided by rotational angiography is a safe and effective method. Our results indicate that integration of rotational angiographic images into the real-time fluoroscopy can guide the TSP during the procedure. © 2015 John Wiley & Sons Ltd.

  7. Quasi-static puncture resistance behaviors of high-strength polyester fabric for soft body armor

    Directory of Open Access Journals (Sweden)

    Qiu-Shi Wang

    Full Text Available A series of economical and flexible fabrics were prepared using high-strength polyester yarns with different fabric structures, weft density and number of layers. The effect of these factors on quasi-static puncture resistance was comparatively studied. The failure mode of the fabrics was analyzed with SEM photographs. Findings indicate that the structure and the weft density affected the quasi-static puncture resistance property of the fabrics, the plain fabrics had better puncture resistance property than twill and satin fabrics. The max puncture force and puncture energy of the plain fabrics with 160 yarn/10 cm reached the max values which were 107.43 N and 0.44 J, respectively. The number of layers had a linear relationship to quasi-static puncture resistance. The contact pressure and friction of the probe against the fibers were the main hindrance during the quasi-static puncture process and the breakage of the fibers during the penetration was caused by the bend and tensile deformation. Keywords: High-strength polyester fabrics, Fabric structure, Multiple-layer fabrics, Quasi-static puncture resistance

  8. CT-guided biopsies and drainage

    International Nuclear Information System (INIS)

    Scheppers, I.; Wollschlaeger, D.

    2011-01-01

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [de

  9. Puncture Self-Healing Polymers for Aerospace Applications

    Science.gov (United States)

    Gordon, Keith L.; Penner, Ronald K.; Bogert, Phil B.; Yost, W. T.; Siochi, Emilie J.

    2011-01-01

    Space exploration launch costs on the order of $10K per pound provide ample incentive to seek innovative, cost-effective ways to reduce structural mass without sacrificing safety and reliability. Damage-tolerant structural systems can provide a route to avoiding weight penalty while enhancing vehicle safety and reliability. Self-healing polymers capable of spontaneous puncture repair show great promise to mitigate potentially catastrophic damage from events such as micrometeoroid penetration. Effective self-repair requires these materials to heal instantaneously following projectile penetration while retaining structural integrity. Poly(ethylene-co-methacrylic acid) (EMMA), also known as Surlyn is an ionomer-based copolymer that undergoes puncture reversal (self-healing) following high impact puncture at high velocities. However EMMA is not a structural engineering polymer, and will not meet the demands of aerospace applications requiring self-healing engineering materials. Current efforts to identify candidate self-healing polymer materials for structural engineering systems are reported. Rheology, high speed thermography, and high speed video for self-healing semi-crystalline and amorphous polymers will be reported.

  10. Sampling a guide for internal auditors

    CERN Document Server

    Apostolou, Barbara

    2004-01-01

    While it is possible to examine 100 percent of an audit customer's data, the time and cost associated with such a study are often prohibitive. To obtain sufficient, reliable, and relevant information with a limited data set, sampling is an efficient and effective tool. It can help you evaluate the customer's assertions, as well as reach audit conclusions and provide reasonable assurance to your organization. This handbook will help you understand sampling. It also serves as a guide for auditors and students preparing for certification. Topics include: An overview of sampling. Statistical and nonstatistical sampling issues. Sampling selection methods and risks. The pros and cons of popular sampling plans.

  11. Discussion on the method to increase the successful rate of L5/S1 intervertebral disc puncture

    International Nuclear Information System (INIS)

    Zhong Xianyi; Li Liangjun; Yu Chengxin

    2007-01-01

    Objective: To study the effective methods of L 5 /S 1 intervertebral disc puncture without drilling to solve the barriers from iliaca. Methods: (1) puncturing with belly-buttock sticking out: to enlarge waist sacro-iliaca angle to move the puncture point up; (2) puncturing through intervertebral edge: puncturing through L 5 to 1/3 intervertebral disc to make the puncture point move Up; (3) puncturing through L 5 /S 1 intervertebral disc with the self-made puncture location instrument. Results with the methods, 280 cases with L 5 /S 1 intervertebral disc protrusion have been successfully punctured, with successful rate 100%. Conclusion: These methods are ideal and easy to use to treat L 5 /S 1 intervertebral disc protrusion puncture, and worth popularizing. (authors)

  12. Cerebellar Herniation after Lumbar Puncture in Galactosemic Newborn

    Directory of Open Access Journals (Sweden)

    Salih Kalay

    2011-09-01

    Full Text Available Cerebral edema resulting in elevated intracranial pressure is a well-known complication of galactosemia. Lumbar puncture was performed for the diagnosis of clinically suspected bacterial meningitis. Herniation of cerebral tissue through the foramen magnum is not a common problem in neonatal intensive care units because of the open fontanelle in infants. We present the case of a 3-week-old infant with galactosemia who presented with signs of cerebellar herniation after lumbar puncture.

  13. Technological advances and changing indications for lumbar puncture in neurological disorders.

    Science.gov (United States)

    Costerus, Joost M; Brouwer, Matthijs C; van de Beek, Diederik

    2018-03-01

    Technological advances have changed the indications for and the way in which lumbar puncture is done. Suspected CNS infection remains the most common indication for lumbar puncture, but new molecular techniques have broadened CSF analysis indications, such as the determination of neuronal autoantibodies in autoimmune encephalitis. New screening techniques have increased sensitvity for pathogen detection and can be used to identify pathogens that were previously unknown to cause CNS infections. Evidence suggests that potential treatments for neurodegenerative diseases, such as Alzheimer's disease, will rely on early detection of the disease with the use of CSF biomarkers. In addition to being used as a diagnostic tool, lumbar puncture can also be used to administer intrathecal treatments as shown by studies of antisense oligonucleotides in patients with spinal muscular atrophy. Lumbar puncture is generally a safe procedure but complications can occur, ranging from minor (eg, back pain) to potentially devastating (eg, cerebral herniation). Evidence that an atraumatic needle tip design reduces complications of lumbar puncture is compelling, and reinforces the need to change clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Use of Lumbar Punctures in the Management of Ocular Syphilis.

    Science.gov (United States)

    Reekie, Ian; Reddy, Yaviche

    2018-01-01

    Ocular syphilis has become rare in the developed world, but is a common presentation to ophthalmology departments in South Africa. We investigated the proportion of patients diagnosed with ocular syphilis who went on to receive lumbar punctures, and determined the fraction of these who had cerebrospinal fluid findings suggestive of neurosyphilis. We aimed to determine whether the use of lumbar punctures in ocular syphilis patients was beneficial in picking up cases of neurosyphilis. Retrospective study of case notes of patients admitted to two district hospitals in Durban, South Africa, with ocular syphilis over a 20-month period. A total of 31 of 68 ocular syphilis patients underwent lumbar puncture, and of these, eight (25.8%) had findings suggestive of neurosyphilis. Lumbar puncture in ocular syphilis patients should continue to be a routine part of the investigation of these patients; a large proportion of ocular syphilis patients show cerebrospinal fluid findings suggestive of neurosyphilis, are at risk of the complications of neurosyphilis, and should be managed accordingly.

  15. Secondary tracheoesophageal puncture in-office using Seldinger technique.

    Science.gov (United States)

    Britt, Christopher J; Lippert, Dylan; Kammer, Rachael; Ford, Charles N; Dailey, Seth H; McCulloch, Timothy; Hartig, Gregory

    2014-05-01

    Evaluate the safety and efficacy of in-office secondary tracheoesophageal puncture (TEP) technique using transnasal esophagoscopy (TNE) and the Seldinger technique in conjunction with a cricothyroidotomy kit for placement. Case series with chart review. Academic medical center. A retrospective chart review was performed on 83 subjects who underwent in-office secondary TEP. Variables that were examined included disease site, staging, histologic diagnosis, extent of resection and reconstruction, chemoradiation, functional voice status (as assessed by speech pathologist in most recent note), and complications directly related to the procedure. Eighty-three individuals from our institution met our criteria for in-office secondary TEP from 2005 to August 2012. Of these, 97.6% (81/83) had no complications of TEP. The overall complication rate was 2.4% (2/83). Complications included bleeding from puncture site and closure of puncture site after dislodgement of prosthesis at the time of puncture. Fluent conversational speech was achieved in 69.9% of all patients (58/83), and an additional 19.3% (16/83) achieved functional/intelligible speech; of those, 3.6% (3/83) were unable to achieve fluent conversational speech due to anatomic defects from previous surgery. An in-office TEP can be safely performed using the Seldinger technique with direct visualization using TNE, despite the extent of resection or reconstruction, with functional speech outcomes comparable to other studies available in the literature.

  16. 彩超引导肾穿刺在肾积水引流中的应用价值%Color Dopplar Ultrasound Guidance of Hydronephrosis Puncture Drainage the ApplicationValue

    Institute of Scientific and Technical Information of China (English)

    于立江; 王希路; 张颖

    2014-01-01

    Objective:To explore the colour dopplar ultrasound guide hydronephrosis puncture of the drainage application value .Meth-ods:Retrospective analysis of 22 cases in hydronephrosis with colour dopplar ultrasound to exceed guided puncture , placed the tube .Re-sults:22 cases are all drainage success , of hydronephrosis ease and all did not appear serious complications .Conclusion:Colour dopplar ultrasound can reveal organization structure and vascular distribution of hydronephrosis under puncture point , and improve the success rate and security .%目的:探讨彩超引导在肾积水穿刺引流中的应用价值。方法:回顾性分析22例肾积水患者在彩超引导下穿刺,放置引流管。结果:22例患者均引流成功,肾积水缓解均未出现严重并发症。结论:彩超可以明确肾积水穿刺点下的组织结构及血管分布,提高了穿刺成功率和安全性。

  17. Understanding of percutaneous puncture under guidance of ultrasound in treating peritoneal and perinephritic abscess

    International Nuclear Information System (INIS)

    Huang Liying; Wang Jiagang

    2010-01-01

    Objective: To explore the clinical value of percutaneous puncture under guidance of ultrasound in treating peritoneal abscess. Methods: To summarize 68 patients with peritoneal abscess underwent percutaneous puncture under guidance of ultrasound to analyse the method of operation and therapeutic effect. Results: effective power of percutaneous puncture under guidance of ultrasound in treating peritoneal abscess was 96.8%. Conclusion: Percutaneous puncture under guidance of ultrasound in treating peritoneal abscess may avoid injury induced by blinded puncture, with characteristic of easier operation, slighter trauma. higher safety, significant therapeutic effect, and can be spreaded to the clinical application. (authors)

  18. Sample holder for studying temperature dependent particle guiding

    International Nuclear Information System (INIS)

    Bereczky, R.J.; Toekesi, K.; Kowarik, G.; Aumayr, F.

    2011-01-01

    Complete text of publication follows. The so called guiding effect is a complex process involving the interplay of a large number of charged particles with a solid. Although many research groups joined this field and carried out various experiments with insulator capillaries many details of the interactions are still unknown. We investigated the temperature dependence of the guiding since it opens new possibilities both for a fundamental understanding of the guiding phenomenon and for applications. For the temperature dependent guiding experiments a completely new heatable sample holder was designed. We developed and built such a heatable sample holder to make accurate and reproducible studies of the temperature dependence of the ion guiding effect possible. The target holder (for an exploded view see Fig. 1) consists of two main parts, the front and the back plates. The two plates of the sample holder, which function as an oven, are made of copper. These parts surround the capillary in order to guarantee a uniform temperature along the whole tube. The temperature of the copper parts is monitored by a K-Type thermocouple. Stainless steel coaxial heaters surrounding the oven are used for heating. The heating power up to a few watts is regulated by a PID controller. Cooling of the capillary is achieved by a copper feed-through connected to a liquid nitrogen bath outside the UHV chamber. This solution allows us to change the temperature of the sample from -30 deg C up to 90 deg C. Our experiments with this newly developed temperature regulated capillary holder show that the glass temperature (i.e. conductivity) can be used to control the guiding properties of the glass capillary and adjust the conditions from guiding at room temperature to simple geometrical transmission at elevated temperatures. This holds the promise to investigate the effect of conductivity on particle transport (build-up and removal of charge patches) through capillaries in more details

  19. The feasibility of trans-abdominal biopsy by ultrasound guiding during uterine artery embolization for benign diseases of uterus

    International Nuclear Information System (INIS)

    Guo Wenbo; Yang Jianyong; Chen Wei; Zhuang Wenquan; Li Heping; Yao Shuzhong

    2006-01-01

    Objective: To investigate the feasibility of trans-abdominal biopsy by ultrasound guiding during uterine artery embolization (UAE) for uterine fibroids and adenomyosis. Methods: Trans-abdominal biopsies by ultrasound guiding were performed in 62 cases of uterine fibroids or adenomyosis diagnosed pre-UAE. Multi-points in focus were punctured in single lesion and multi-points in every focus of multiple lesions were punctured. The diagnosis before UAE was made according to clinical symptoms, pelvic ultrasound and pelvic magnetic resonance imaging (MRI). The pathological diagnosis by biopsy was comparative to its clinical diagnosis before biopsy. The complications were also observed. Results: Biopsies were performed successfully in 60 cases with pathological examination, including 52 uterine fibroids and 8 adenomyosis cases. The clinical diagnosis of uterine fibroids or adenomyosis was coincident with the pathology except 2 cases of fibroids diagnosed before biopsy were failed to puncture. Conclusion: Trans-abdominal biopsy by ultrasound guiding in uterine artery embolization for benign diseases of uterus is safe and feasible. (authors)

  20. Subarachnoid and basal cistern navigation through the sacral hiatus with guide wire assistance.

    Science.gov (United States)

    Layer, Lauren; Riascos, Roy; Firouzbakht, Farhood; Amole, Adewumi; Von Ritschl, Rudiger; Dipatre, Pier; Cuellar, Hugo

    2011-07-01

    Intraspinal navigation with catheters and fiberscopes has shown feasible results for diagnosis and treatment of intraspinal and intracranial lesions. The most common approach, lumbar puncture, has allowed access to the spinal cord, however, coming with the difficulties of fiberscope damage and decreased torque for guidance. Our objective in this study is to allow an alternate access, the sacral hiatus, with guide wire assistance into the subarachnoid and intracranial structures, while easing the angle of entry and increasing torque. We advanced catheters with guide wire and fluoroscopy assistance into the sacral hiatus of three cadavers. After entry, the thecal sac was punctured and the catheter with guide wire was advanced rostrally until positioned in the basal cisterns of the brain. We confirmed catheter placement with contrast injection, autopsy, and dissection. In our study, the sacral hiatus was easily accessed, but resistance was found when attempting to puncture the thecal sac. The advancement of the catheter with guide wire assistance glided easily rostrally until some mild resistance was discovered at entry into the foramen magnum. With redirection, all catheters passed with ease into the basal cisterns. Positioning was confirmed with contrast injection with fluoroscopy evidence, autopsy, and dissection. There was no macroscopic or microscopic evidence of damage to the spinal roots, spinal cord, or cranial nerves. The sacral hiatus with guide wire assistance is an accessible conduit for uncomplicated entry into the subarachnoid and basal cistern space without damaging surrounding structures.

  1. Puncture mechanics of soft elastomeric membrane with large deformation by rigid cylindrical indenter

    Science.gov (United States)

    Liu, Junjie; Chen, Zhe; Liang, Xueya; Huang, Xiaoqiang; Mao, Guoyong; Hong, Wei; Yu, Honghui; Qu, Shaoxing

    2018-03-01

    Soft elastomeric membrane structures are widely used and commonly found in engineering and biological applications. Puncture is one of the primary failure modes of soft elastomeric membrane at large deformation when indented by rigid objects. In order to investigate the puncture failure mechanism of soft elastomeric membrane with large deformation, we study the deformation and puncture failure of silicone rubber membrane that results from the continuous axisymmetric indentation by cylindrical steel indenters experimentally and analytically. In the experiment, effects of indenter size and the friction between the indenter and the membrane on the deformation and puncture failure of the membrane are investigated. In the analytical study, a model within the framework of nonlinear field theory is developed to describe the large local deformation around the punctured area, as well as to predict the puncture failure of the membrane. The deformed membrane is divided into three parts and the friction contact between the membrane and indenter is modeled by Coulomb friction law. The first invariant of the right Cauchy-Green deformation tensor I1 is adopted to predict the puncture failure of the membrane. The experimental and analytical results agree well. This work provides a guideline in designing reliable soft devices featured with membrane structures, which are present in a wide variety of applications.

  2. Liouville theory and uniformization of four-punctured sphere

    Science.gov (United States)

    Hadasz, Leszek; Jaskólski, Zbigniew

    2006-08-01

    A few years ago Zamolodchikov and Zamolodchikov proposed an expression for the four-point classical Liouville action in terms of the three-point actions and the classical conformal block [Nucl. Phys. B 477, 577 (1996)]. In this paper we develop a method of calculating the uniformizing map and the uniformizing group from the classical Liouville action on n-punctured sphere and discuss the consequences of Zamolodchikovs conjecture for an explicit construction of the uniformizing map and the uniformizing group for the sphere with four punctures.

  3. Rare patterns of dorsal puncture in Pterostichus oblongopunctatus (Coleoptera: Carabidae

    Directory of Open Access Journals (Sweden)

    Axel Schwerk

    2018-04-01

    Full Text Available Background The carabid beetle species Pterostichus oblongopunctatus is common in different types of forests in Poland and Europe. With respect to this species, some unclarities exist concerning the morphological feature of punctures on the elytra. P. oblongopunctatus has dorsal pits in the third interval of the elytra, the available identification keys, however, provide inconsistent information concerning the puncture in other intervals. During long-term studies at different study sites in Poland, the first author rarely but regularly discovered individuals with unusual dorsal puncture patterns, i.e., pits in the fifth and even in the seventh interval of the elytra. Since such rare patterns might be connected with special habitat characteristics, and thus have a potential as an indicator, the aim of the study was to test if they are connected with specific subpopulations (interaction groups, if they are related to the sex or size of the beetles, and if they are related to specific habitat conditions. Material and Methods We counted the pits on the elytra, determined the sex, and measured the length of the right elytron of individuals of P. oblongopunctatus collected at numerous study sites located within the borders of the Regional Directory of National Forests in Piła (Western Poland over the period 2014–2016. Results Altogether, 1,058 individuals of P. oblongopunctatus were subjected to statistical analysis. Almost 19% of the individuals had a dorsal puncture in the fifth interval of the elytra and about 0.7% had a dorsal puncture in the seventh interval of the elytra. In 2014 and 2015, significantly more females exhibited such unusual patterns of dorsal puncture than males. Even if not statistically significant, in 2016 also relatively more females showed such a pattern. Neither males nor females of the analysed individuals with usual puncture patterns showed a significant difference in the length of the right elytron from those with

  4. The impact of different blood sampling methods on laboratory rats under different types of anaesthesia

    DEFF Research Database (Denmark)

    Toft, Martin Fitzner; Petersen, Mikke Haxø; Dragsted, Nils

    2006-01-01

    for rats sampled from the tail vein, which showed fluctuations in body temperature in excess of 30 h after sampling. Increases in heart rate and blood pressure within the first hours after sampling indicated that periorbital puncture was the method that had the largest acute impact on the rats......Rats with implanted telemetry transponders were blood sampled by jugular puncture, periorbital puncture or tail vein puncture, or sampled by jugular puncture in carbon dioxide (CO?), isoflurane or without anaesthesia in a crossover design. Heart rate, blood pressure and body temperature were...... registered for three days after sampling. Initially blood pressure increased, but shortly after sampling it decreased, which led to increased heart rate. Sampling induced rapid fluctuations in body temperature, and an increase in body temperature. Generally, rats recovered from sampling within 2-3 h, except...

  5. MR-guided MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Tratting, S.; Breitenseher, M.; Pretterklieber, M.; Kontaxis, G.; Rand, T.; Imhof, H.

    1996-01-01

    Purpose: To develop an MR-guided technique for joint puncture in MR arthrography of the shoulder and to confirm the intracapsular position of the needle tip by visualization of the flow of contrast media into the joint. Materials and methods: Three unfixed human shoulder joint specimens were examined on a 1.0 T unit. The optimal point of entrance and depth for joint puncture were estimated by means of MR-compatible markers on the skin. Needle orientation and localization of the needle tip (MR-compatible 22-gauge needle) in the shoulder joint were monitored by rapid localizer gradient-echo sequences in two orthogonal planes. To confirm the intracapsular position of the needle tip, diluted gadolinium-DTPA was administered via a long connecting tube and the flow of contrast media into the joint was viewed directly on an LCD screen using real-time MR imaging (local look technique). Results: The MR-compatible markers on the skin allowed determination of the optimal point of entrance and estimation of the depth for joint puncture. Passive visualization of the MR-compatible needle due to spin dephasing and signal loss provided adequate localization of the intra-articular needle tip position in all specimens, although significant artefacts were present on rapid localizer gradient-echo sequences with an increase in width of the apparent needle shaft. Real-time MR imaging of the flow of contrast media was possible using the local look technique and the LCD screen of the MR unit and allowed confirmation of the intracapsular position. Conclusion: MR-guided joint puncture and real-time MR-assisted contrast media application results in improved MR arthrography and may replace conventional fluoroscopic guidance. (orig.) [de

  6. Side effects after diagnostic lumbar puncture and lumbar iohexol myelography

    International Nuclear Information System (INIS)

    Sand, T.; Stovner, L.J.; Salvesen, R.; Dale, L.

    1987-01-01

    A prospective, controlled study was performed to compare side effect incidences after lumbar iohexol myelography (n=97) and diagnostic lumbar puncture (n=85). No significant side effect incidence differences (iohexol vs. controls) were found regarding number of patients with any side effect (63 vs. 73%), headache (44 vs. 54%), nausea, dizziness, visual, auditory, or psychic symptoms. Early-onset headache occurred significantly more often in the iohexol group (16 vs 5%), while postural headache occurred most frequently after lumbar puncture (25 vs. 41%). These results suggest that apart from the slight early-onset headache, most side effets after lumbar iohexol myelography are related to the puncture per se, not to the contrast agent. (orig.)

  7. Technological advances and changing indications for lumbar puncture in neurological disorders

    NARCIS (Netherlands)

    Costerus, Joost M.; Brouwer, Matthijs C.; van de Beek, Diederik

    2018-01-01

    Technological advances have changed the indications for and the way in which lumbar puncture is done. Suspected CNS infection remains the most common indication for lumbar puncture, but new molecular techniques have broadened CSF analysis indications, such as the determination of neuronal

  8. Predisposing factors for peripheral intravenous puncture failure in children

    OpenAIRE

    Negri,Daniela Cavalcante de; Avelar,Ariane Ferreira Machado; Andreoni,Solange; Pedreira,Mavilde da Luz Gonçalvez

    2012-01-01

    OBJECTIVE: To identify predisposing factors for peripheral intravenous puncture failure in children. METHODS: Cross-sectional cohort study conducted with 335 children in a pediatric ward of a university hospital after approval of the ethics committee. The Wald Chi-squared, Prevalence Ratio (PR) and backward procedure (p≤0.05) tests were applied. RESULTS: Success of peripheral intravenous puncture was obtained in 300 (89.5%) children and failure in 35 (10.4%). The failure rates were sign...

  9. Standard guide for sampling radioactive tank waste

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This guide addresses techniques used to obtain grab samples from tanks containing high-level radioactive waste created during the reprocessing of spent nuclear fuels. Guidance on selecting appropriate sampling devices for waste covered by the Resource Conservation and Recovery Act (RCRA) is also provided by the United States Environmental Protection Agency (EPA) (1). Vapor sampling of the head-space is not included in this guide because it does not significantly affect slurry retrieval, pipeline transport, plugging, or mixing. 1.2 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Needle puncture in rabbit functional spinal units alters rotational biomechanics.

    Science.gov (United States)

    Hartman, Robert A; Bell, Kevin M; Quan, Bichun; Nuzhao, Yao; Sowa, Gwendolyn A; Kang, James D

    2015-04-01

    An in vitro biomechanical study for rabbit lumbar functional spinal units (FSUs) using a robot-based spine testing system. To elucidate the effect of annular puncture with a 16 G needle on mechanical properties in flexion/extension, axial rotation, and lateral bending. Needle puncture of the intervertebral disk has been shown to alter mechanical properties of the disk in compression, torsion, and bending. The effect of needle puncture in FSUs, where intact spinal ligaments and facet joints may mitigate or amplify these changes in the disk, on spinal motion segment stability subject to physiological rotations remains unknown. Rabbit FSUs were tested using a robot testing system whose force/moment and position precision were assessed to demonstrate system capability. Flexibility testing methods were developed by load-to-failure testing in flexion/extension, axial rotation, and lateral bending. Subsequent testing methods were used to examine a 16 G needle disk puncture and No. 11 blade disk stab (positive control for mechanical disruption). Flexibility testing was used to assess segmental range-of-motion (degrees), neutral zone stiffness (N m/degrees) and width (degrees and N m), and elastic zone stiffness before and after annular injury. The robot-based system was capable of performing flexibility testing on FSUs-mean precision of force/moment measurements and robot system movements were elastic zone stiffness in flexion and lateral bending. These findings suggest that disk puncture and stab can destabilize FSUs in primary rotations.

  11. Computation of Quantum Bound States on a Singly Punctured Two-Torus

    International Nuclear Information System (INIS)

    Kar-Tim Chan; Zainuddin Hishamuddin; Molladavoudi Saeid

    2013-01-01

    We study a quantum mechanical system on a singly punctured two-torus with bound states described by the Maass waveforms which are eigenfunctions of the hyperbolic Laplace—Beltrami operator. Since the discrete eigenvalues of the Maass cusp form are not known analytically, they are solved numerically using an adapted algorithm of Hejhal and Then to compute Maass cusp forms on the punctured two-torus. We report on the computational results of the lower lying eigenvalues for the punctured two-torus and find that they are doubly-degenerate. We also visualize the eigenstates of selected eigenvalues using GridMathematica

  12. Aortic intracardiac echocardiography-guided septal puncture during mitral valvuloplasty.

    Science.gov (United States)

    Akkaya, Emre; Vuruskan, Ertan; Zorlu, Ali; Sincer, Isa; Kucukosmanoglu, Mehmet; Ardic, Idris; Yilmaz, Mehmet Birhan

    2014-01-01

    Transoesophageal echocardiography (TEE) and venous intracardiac echocardiography (ICE) are traditionally used to visualize the interatrial septum (IAS) and the tenting effect of the fossa ovalis in patients undergoing percutaneous balloon mitral valvuloplasty (PBMV). The aim of the present study was to assess the comparative efficacy and safety of arterial (intra-aortic) ICE and venous ICE, compared with TEE (traditional approach), in the patients undergoing PBMV. TEE, aortic ICE, and venous ICE were consecutively performed in 50 patients (40 ± 9 years, 86% female). The images of intracardiac structures were obtained from both aortic and right atrial loci. The IAS was visualized using TEE, aortic ICE, and venous ICE. The mean mitral valve area was 1.14 ± 0.2 cm(2), and the mean left atrial volume index was 57.5 ± 12 mL/m(2). The mean size of the visualized septal length was 48 ± 5 mm by TEE, 51 ± 5 mm by aortic ICE, and 33 ± 6 mm by venous ICE. The Bland-Altman test indicated that the 95% limits of agreement for the measurement of septal diameter ranged from -11.0 to +5.9 mm (mean -2.5 mm) between TEE and aortic ICE, -2.8 to +33.5 mm (mean +15.3 mm) between TEE and venous ICE, and -36.6 to +0.8 mm (mean -17.9 mm) between venous and aortic ICE. Standard venous ICE generally tended to yield smaller values compared with TEE and aortic ICE for the measurement of septal length. Furthermore, the view of fossa ovalis and 'tenting effect' was optimal in 11 patients on venous ICE; however, the fossa ovalis and tip of the needle were well visualized in all patients on aortic ICE (P < 0.001). There were no major complications with the use of aortic ICE. Aortic ICE is a superior alternative to venous ICE and facilitates trans-septal puncture in patients with mitral stenosis.

  13. Percutaneous Transhepatic Catheterization of the Portal Vein: A Combined CT- and Fluoroscopy-Guided Technique

    International Nuclear Information System (INIS)

    Weimar, Bernd; Rauber, Klaus; Brendel, Mathias D.; Bretzel, Reinhard G.; Rau, Wigbert S.

    1999-01-01

    Combined CT- and fluoroscopy-guided transhepatic portal vein catheterization was performed in 44 patients selected for pancreatic islet cell transplantation. The method allowed catheterization with a single puncture attempt in 39 patients. In four patients two attempts and in one patient four attempts were necessary. One minor hematoma of the liver capsule occurred that required no further treatment. Compared with other methods the average number of puncture attempts was reduced

  14. Analysis of the indications for routine lumbar puncture and results of ...

    African Journals Online (AJOL)

    Lumbar puncture (LP) is an important diagnostic tool for investigating neurological conditions/diseases. This study was carried out to compare the indications for lumbar puncture and findings of cerebrospinal fluid examination in children admitted to Muhimbili National Hospital (MNH) in Dar-es-salaam, Tanzania and Kilifi ...

  15. Effects of electron beam radiation on mechanical properties and on the resistance to punctures caused by Plodia interpunctella in cereal bar packaging

    International Nuclear Information System (INIS)

    Alves, Juliana N.; Moura, Esperidiana A.B.; Oliveira, Vitor M.; Potenza, Marcos R.; Arthur, Valter

    2009-01-01

    Plodia interpunctella is an important pest in stored products in the tropical and subtropical regions, infesting grains and flours. The adult of P. interpunctella is a small butterfly with about 15 - 20mm of spread and the female places separately of 100 the 400 eggs in groups on the grains whose hard incubation some days. This insect infesting diverse types of food packaging, depreciating the products and causing economic losses. It is therefore critical for these products a packaging that presents, in addition to good mechanical, barrier and machinability properties, a good resistance to puncture by insects, in order to prevent the contact and spread of pests in the packaged food. This study evaluates the changes on mechanical properties and puncture resistance by P. interpunctella in BOPPmet/BOPP structure, used commercially as cereal bar packaging, after electron beam irradiation. The material samples were irradiated up to 120 kGy using a 1.5 MeV electrostatic accelerator, at room temperature, in air, dose rate 11.22 kGy/s. Irradiation doses were measured using cellulose triacetate film dosimeters 'CTA-FTR-125' from Fuji Photo Film Co. Ltd. After irradiation the BOPPmet/BOPP samples were subjected to tests of puncture resistance by P. interpunctella, tensile tests and penetration resistance. The results showed significant decreases (p<0.05) in the original mechanical properties of the structures according to the radiation doses applied and effective resistance against punctures by P. interpunctella for irradiated and nonirradiated BOPPmet/BOPP samples. These results indicate that non-irradiated and irradiated BOPPmet/BOPP structure presents puncture resistance against P. interpunctella and that electron-beam irradiation, in conditions studied in this work, may turn the structure inappropriate for cereal bar packaging, due to high reduction its mechanical properties after irradiation. (author)

  16. Changes in cerebral haemodynamics in cases of post-lumbar puncture headache: a prospective transcranial Doppler ultrasound study

    International Nuclear Information System (INIS)

    Goebel, H.; Klostermann, H.; Lindner, V.; Schenkl, S.

    1990-01-01

    Transcranial Doppler ultrasonography was used in 45 patients to investigate if changes in haemodynamics in the major arteries of the brain base occurred after lumbar puncture and whether or not patients with or without post-lumbar puncture headache differ with respect to their cerebral haemodynamic parameters before and after lumbar puncture. Before lumbar puncture, patients with post-lumbar puncture headache differed from patients withoput post-lumbar puncture headache in that they showed significantly higher flow velocities and significant asymmetry of flow velocities with lateralization to the right. Patients without post-lumbar puncture headache, on the other hand, showed non-significant flow velocity lateralization to the left. Forty-eight hours after lumbar puncture, both groups demonstrated symmetrical flow velocities. In addition, only patients with post-lumbar puncture headache showed a significant reduction in the flow velocity of the right middle cerebral artery. These findings suggest that it is not only absolute flow velocity that plays a part in the event of headache; the interhemispheric relation of cerebral haemodynamics also plays a fundamental role. 14 refs., 3 figs., 2 tabs

  17. Stenting-plasty with brachial puncture in the treatment of subclavian steal syndrome

    International Nuclear Information System (INIS)

    Chen Quan; Jing Zaiping; Zhao Zhiqing; Feng Xiang; Lu Qingsheng; Mei Zhijun

    2007-01-01

    Objective: To study the clinical effect of stenting-plasty with retrograde brachial puncture for subclavian steal syndrome patients. Methods: To analyze the clinical results of stenting-plasty with retrograde brachial puncture in 15 patients with subclavian steal syndrome. Results: MRA or DSA showed the subclavian arteries with different degrees of stenosis (80%-100%) in all patients. Stenting-plasty with retrograde brachia] puncture was used in all patients. After placement of wall or polmaz stent, the pulse recovered and the syndrome disappeared. Postoperative angiography showed patency of the artery and stent. The patients were followed up for 3-30 months without recurrence of symptoms. Conclusions: Stenting-plasty with retrograde brachial puncture is a rather proper method to treat subclavian steal syndrome with more coincidence to the vascular anatomy, decrease the maneuver trouble and increase the successful rate. (authors)

  18. 1.0 T open-configuration magnetic resonance-guided microwave ablation of pig livers in real time

    Science.gov (United States)

    Dong, Jun; Zhang, Liang; Li, Wang; Mao, Siyue; Wang, Yiqi; Wang, Deling; Shen, Lujun; Dong, Annan; Wu, Peihong

    2015-01-01

    The current fastest frame rate of each single image slice in MR-guided ablation is 1.3 seconds, which means delayed imaging for human at an average reaction time: 0.33 seconds. The delayed imaging greatly limits the accuracy of puncture and ablation, and results in puncture injury or incomplete ablation. To overcome delayed imaging and obtain real-time imaging, the study was performed using a 1.0-T whole-body open configuration MR scanner in the livers of 10 Wuzhishan pigs. A respiratory-triggered liver matrix array was explored to guide and monitor microwave ablation in real-time. We successfully performed the entire ablation procedure under MR real-time guidance at 0.202 s, the fastest frame rate for each single image slice. The puncture time ranged from 23 min to 3 min. For the pigs, the mean puncture time was shorted to 4.75 minutes and the mean ablation time was 11.25 minutes at power 70 W. The mean length and widths were 4.62 ± 0.24 cm and 2.64 ± 0.13 cm, respectively. No complications or ablation related deaths during or after ablation were observed. In the current study, MR is able to guide microwave ablation like ultrasound in real-time guidance showing great potential for the treatment of liver tumors. PMID:26315365

  19. Experimental model of intervertebral disc degeneration by needle puncture in Wistar rats

    International Nuclear Information System (INIS)

    Issy, A.C.; Castania, V.; Castania, M.; Salmon, C.E.G.; Nogueira-Barbosa, M.H.; Bel, E. Del; Defino, H.L.A.

    2013-01-01

    Animal models of intervertebral disc degeneration play an important role in clarifying the physiopathological mechanisms and testing novel therapeutic strategies. The objective of the present study is to describe a simple animal model of disc degeneration involving Wistar rats to be used for research studies. Disc degeneration was confirmed and classified by radiography, magnetic resonance and histological evaluation. Adult male Wistar rats were anesthetized and submitted to percutaneous disc puncture with a 20-gauge needle on levels 6-7 and 8-9 of the coccygeal vertebrae. The needle was inserted into the discs guided by fluoroscopy and its tip was positioned crossing the nucleus pulposus up to the contralateral annulus fibrosus, rotated 360° twice, and held for 30 s. To grade the severity of intervertebral disc degeneration, we measured the intervertebral disc height from radiographic images 7 and 30 days after the injury, and the signal intensity T2-weighted magnetic resonance imaging. Histological analysis was performed with hematoxylin-eosin and collagen fiber orientation using picrosirius red staining and polarized light microscopy. Imaging and histological score analyses revealed significant disc degeneration both 7 and 30 days after the lesion, without deaths or systemic complications. Interobserver histological evaluation showed significant agreement. There was a significant positive correlation between histological score and intervertebral disc height 7 and 30 days after the lesion. We conclude that the tail disc puncture method using Wistar rats is a simple, cost-effective and reproducible model for inducing disc degeneration

  20. Experimental model of intervertebral disc degeneration by needle puncture in Wistar rats

    Energy Technology Data Exchange (ETDEWEB)

    Issy, A.C.; Castania, V.; Castania, M. [Departamento de Morfologia, Fisiologia e Patologia Básica, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Salmon, C.E.G. [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Nogueira-Barbosa, M.H. [Divisão de Radiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Bel, E. Del [Departamento de Morfologia, Fisiologia e Patologia Básica, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Defino, H.L.A. [Departamento de Biomecânica, Medicina e Reabilitação do Sistema Locomotor, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2013-03-15

    Animal models of intervertebral disc degeneration play an important role in clarifying the physiopathological mechanisms and testing novel therapeutic strategies. The objective of the present study is to describe a simple animal model of disc degeneration involving Wistar rats to be used for research studies. Disc degeneration was confirmed and classified by radiography, magnetic resonance and histological evaluation. Adult male Wistar rats were anesthetized and submitted to percutaneous disc puncture with a 20-gauge needle on levels 6-7 and 8-9 of the coccygeal vertebrae. The needle was inserted into the discs guided by fluoroscopy and its tip was positioned crossing the nucleus pulposus up to the contralateral annulus fibrosus, rotated 360° twice, and held for 30 s. To grade the severity of intervertebral disc degeneration, we measured the intervertebral disc height from radiographic images 7 and 30 days after the injury, and the signal intensity T2-weighted magnetic resonance imaging. Histological analysis was performed with hematoxylin-eosin and collagen fiber orientation using picrosirius red staining and polarized light microscopy. Imaging and histological score analyses revealed significant disc degeneration both 7 and 30 days after the lesion, without deaths or systemic complications. Interobserver histological evaluation showed significant agreement. There was a significant positive correlation between histological score and intervertebral disc height 7 and 30 days after the lesion. We conclude that the tail disc puncture method using Wistar rats is a simple, cost-effective and reproducible model for inducing disc degeneration.

  1. Does obesity preclude lumbar puncture with a standard spinal needle? The use of computed tomography to measure the skin to lumbar subarachnoid space distance in the general hospital population.

    LENUS (Irish Health Repository)

    Halpenny, Darragh

    2013-06-05

    OBJECTIVES: Failed lumbar puncture (LP) is a common indication for referral for radiologically guided LP. This study aims to evaluate what percentage of the hospital population would fail an LP using a standard 9-cm needle because of obesity and a skin to subarachnoid space distance greater than 9 cm. METHODS: Images of 402 consecutive patients undergoing computed tomography of the abdomen and pelvis were reviewed. Skin to subarachnoid space distance was calculated using sagittal images. A survey was conducted among junior hospital doctors to assess their experience of performing lumbar puncture in obese patients. RESULTS: Four hundred patients were included. Fifty-five patients (13.8 %) had a skin to subarachnoid space distance greater than 9 cm. Intra-abdominal fat, subcutaneous fat and abdominal girth correlated with distance between the skin and subarachnoid space. Among junior doctors, 68.3 % (n = 41) reported LP failure on an obese patient; 78.4 % (n = 47) were unaware of the existence of a longer needle and 13.3 % (n = 8) had experience using a longer needle. CONCLUSIONS: A significant proportion of the hospital population will fail LP with a standard length spinal needle. Selecting a longer needle may be sufficient to successfully complete LP in obese patients. KEY POINTS : • Lumbar puncture failure commonly leads to referral for an image-guided procedure • Standard lumbar puncture may fail in 13.8 % of patients due to obesity • 78.4 % of trainee doctors are unaware of the existence of longer spinal-needles • Using longer spinal needles may allow successful LP in obese patients.

  2. In-Plane Ultrasound-Guided Knee Injection Through a Lateral Suprapatellar Approach: A Safe Technique.

    Science.gov (United States)

    Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H

    2017-06-01

    This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.

  3. Optimization of multi-channel neutron focusing guides for extreme sample environments

    International Nuclear Information System (INIS)

    Di Julio, D D; Lelièvre-Berna, E; Andersen, K H; Bentley, P M; Courtois, P

    2014-01-01

    In this work, we present and discuss simulation results for the design of multichannel neutron focusing guides for extreme sample environments. A single focusing guide consists of any number of supermirror-coated curved outer channels surrounding a central channel. Furthermore, a guide is separated into two sections in order to allow for extension into a sample environment. The performance of a guide is evaluated through a Monte-Carlo ray tracing simulation which is further coupled to an optimization algorithm in order to find the best possible guide for a given situation. A number of population-based algorithms have been investigated for this purpose. These include particle-swarm optimization, artificial bee colony, and differential evolution. The performance of each algorithm and preliminary results of the design of a multi-channel neutron focusing guide using these methods are described. We found that a three-channel focusing guide offered the best performance, with a gain factor of 2.4 compared to no focusing guide, for the design scenario investigated in this work.

  4. Impact of Corrugated Paperboard Structure on Puncture Resistance

    Directory of Open Access Journals (Sweden)

    Vaidas Bivainis

    2015-03-01

    Full Text Available Thanks to its excellentprotective properties, lightness, a reasonable price, and ecology, corrugated paperboardis one of the most popular materials used in the production of packaging for variousproducts. During transportation or storage, packaging with goods can be exposedto the mass of other commodities, dropping from heights and transportationshock loads, which can lead to their puncture damage. Depending on the purposeand size of the packaging, the thickness, grammage, constituent paper layers,numbers of layers and type of fluting of corrugated paperboard used in itsproduction differ. A standard triangular prism, corrugated paperboard fixationplates and a universal tension-compression machine were used to investigate theimpact of corrugated paperboard structure and other parameters on the punctureresistance of the material. The investigation determines the maximum punctureload and estimates energy required to penetrate the corrugated paperboard. Itwas found that the greatest puncture resistance is demonstrated by paperboardwith a larger number of corrugating flutings and the board produced from harderpaper with a smaller amount of recycled paper. It was established that thegrammage of three-layered paperboard with two different fluting profiles has thegreatest impact on the level of static puncture energy.DOI: http://dx.doi.org/10.5755/j01.ms.21.1.5713

  5. Performance and complications of lumbar puncture in memory clinics : Results of the multicenter lumbar puncture feasibility study

    NARCIS (Netherlands)

    Duits, Flora H.; Martinez-Lage, Pablo; Paquet, Claire; Engelborghs, Sebastiaan; Lleo, Alberto; Hausner, Lucrezia; Molinuevo, Jose L.; Stomrud, Erik; Farotti, Lucia; Ramakers, Inez H. G. B.; Tsolaki, Magda; Skarsgard, Constance; Astrand, Ragnar; Wallin, Anders; Vyhnalek, Martin; Holmber-Clausen, Marie; Forlenza, Orestes V.; Ghezzi, Laura; Ingelsson, Martin; Hoff, Erik I.; Roks, C.M.A.A.; de Mendonca, Alexandre; Papma, Janne M.; Izagirre, Andrea; Taga, Mariko; Struyfs, Hanne; Alcolea, Daniel A.; Froelich, Lutz; Balasa, Mircea; Minthon, Lennart; Twisk, Jos W. R.; Persson, Staffan; Zetterberg, Henrik; van der Flier, Wiesje M.; Teunissen, Charlotte E.; Scheltens, Philip; Blennow, Kaj

    2016-01-01

    Introduction Lumbar puncture (LP) is increasingly performed in memory clinics. We investigated patient-acceptance of LP, incidence of and risk factors for post-LP complications in memory clinic populations. Methods We prospectively enrolled 3868 patients (50% women, age 66 ± 11 years, mini mental

  6. MR imaging with gadolinium in patients with and without post-lumbar puncture headache

    International Nuclear Information System (INIS)

    Hannerz, J.; Ericson, K.; Bro Skejoe, H.P.

    1999-01-01

    Purpose: To study frequency and extent of meningeal enhancement in patients with and without post-lumbar puncture headache (PLPH) with cerebral MR with Gd-DTPA. Material and methods: Ten consecutive patients with PLPH and 9 consecutive patients without PLPH were included in the study. Nine of the PLPH patients were reinvestigated when the PLPH was over and all non-PLPH patients during the week after the lumbar puncture. Results: Eight of the 9 patients with PLPH showed more enhancement of meningeal structures during PLPH than when PLPH had disappeared. The differences were slight in 5, more marked in 2, and pronounced in 1 patient. The 9th patient showed no change at all. In the 9 patients without PLPH, there was mainly slight enhancement before lumbar puncture and no change in enhancement after lumbar puncture as compared with before. Conclusion: PLPH is related to increased Gd-DTPA enhancement of the meninges, although the increase in enhancement during PLPH is minor in most cases. Pronounced enhancement of the meninges after lumbar puncture may predict long duration of the PLPH. (orig.)

  7. Experimental analysis of Kevlar modification for TRUPACT-I puncture panels

    International Nuclear Information System (INIS)

    Longenbaugh, R.S.; Joseph, B.J.

    1987-05-01

    The Kevlar Test Services was initiated to determine the maximum failure force and the energy-absorbing capability of puncture panels consisting of 16, 20, and 24 layers of 3000-denier 4 x 4 basket weave Kevlar-29, bonded to a 3.41 mm 304 annealed stainless steel puncture plate. Results of these tests were compared to the TRUPACT-1 Unit-0 drop test results to determine if the existing puncture panel configuration of TRUPACT-1 could be reduced. The data indicate for 24 layers of Kevlar, the panels failed at loads greater than those recorded in the TRUPACT-1, Unit 0 tests. Energy absorbed by the 24-layer Kevlar panels was 53% greater than that measured in the TRUPACT-1, Unit 0 test. Thermal performance of 20-layer Kevlar panels was measured in a conservative test environment and exceeded the design specifications

  8. Unintentional arterial puncture during cephalic vein cannulation: case report and anatomical study

    NARCIS (Netherlands)

    Lirk, P.; Keller, C.; Colvin, J.; Colvin, H.; Rieder, J.; Maurer, H.; Moriggl, B.

    2004-01-01

    The cephalic antebrachial vein is often used for venous access. However, superficial radial arteries of the forearm are known and unintentional arterial puncture can result from attempts to cannulate the lateral veins of the arm. Accidental puncture of a superficial radial artery during peripheral

  9. MR-guided discography using an open 1 Tesla MRI system

    International Nuclear Information System (INIS)

    Streitparth, Florian; Bucourt, M. de; Hamm, B.; Teichgraeber, U.; Hartwig, T.; Strube, P.; Putzier, M.; Schnackenburg, B.; Chopra, S.

    2011-01-01

    To evaluate the feasibility of MR-guided discography using an open 1 Tesla MRI system. 48 disc segments of 41 patients scheduled for intradiscal thermal treatment, total disc replacement or spondylodesis were examined. A 1.0-T open MRI was used for instrument guidance and imaging. After primary disc puncture under guidance of interactive PDw TSE imaging, 1-2 ml of gadolinium contrast saline mixture was injected into the disc. The occurrence of memory pain during injection was recorded. Axial and sagittal T1w TSE images with and without fat saturation were obtained. All MRI discograms were analysed by two readers, who were blinded to the clinical findings. Overall, the placement of the puncture needle in the targeted disc was accurate under real-time MR guidance. Injections were technically successful in all cases. No major complications occurred. The mean procedure time was 17 min (range 13-34 min). Image quality of contrast-enhanced MR discograms was excellent when using an optimized gadolinium contrast saline mixture of 1:600. Memory pain was detected in 16 out of 48 affected segments. MR-guided discography is accurate and safe. Multiplanar dynamic imaging facilitates the puncture of discs and provides high-quality MR discograms. (orig.)

  10. Mechanical deformation and glycosaminoglycan content changes in a rabbit annular puncture disc degeneration model.

    Science.gov (United States)

    Chan, Deva D; Khan, Safdar N; Ye, Xiaojing; Curtiss, Shane B; Gupta, Munish C; Klineberg, Eric O; Neu, Corey P

    2011-08-15

    Evaluation of degenerated intervertebral discs from a rabbit annular puncture model by using specialized magnetic resonance imaging (MRI) techniques, including displacement encoding with stimulated echoes and a fast-spin echo (DENSE-FSE) acquisition and delayed gadolinium-enhanced MRI of cartilage (dGEMRIC). To evaluate a rabbit disc degeneration model by using various MRI techniques. To determine the displacements and strains, spin-lattice relaxation time (T1), and glycosaminoglycan (GAG) distribution of degenerated discs as compared to normal and adjacent level discs. Annular puncture of the intervertebral disc produces disc degeneration in rabbits. DENSE-FSE has been previously demonstrated in articular cartilage for the measurement of soft tissue displacements and strains. MRI also can measure the T1 of tissue, and dGEMRIC can quantify GAG concentration in cartilage. METHODS.: In eight New Zealand white rabbits, the annulus fibrosis of a lumbar disc was punctured. After 4 weeks, the punctured and cranially adjacent motion segments were isolated for MRI and histology. MRI was used to estimate the disc volume and map T1. DENSE-FSE was used to determine displacements for the estimation of strains. dGEMRIC was then used to determine GAG distributions. Histology and standard MRI indicated degeneration in punctured discs. Disc volume increased significantly at 4 weeks after the puncture. Displacement of the nucleus pulposus was distinct from that of the annulus fibrosis in most untreated discs but not in punctured discs. T1 was significantly higher and GAG concentration significantly lower in punctured discs compared with untreated adjacent level discs. Noninvasive and quantitative MRI techniques can be used to evaluate the mechanical and biochemical changes that occur with animal models of disc degeneration. DENSE-FSE, dGEMRIC, and similar techniques have potential for evaluating the progression of disc degeneration and the efficacy of treatments.

  11. Use of inelastic analysis to determine the response of packages to puncture accidents

    International Nuclear Information System (INIS)

    Ammerman, D.J.; Ludwigsen, J.S.

    1996-01-01

    The accurate analytical determination of the response of radioactive material transportation packages to the hypothetical puncture accident requires inelastic analysis techniques. Use of this improved analysis method recudes the reliance on empirical and approximate methods to determine the safety for puncture accidents. This paper will discuss how inelastic analysis techniques can be used to determine the stresses, strains and deformations resulting from puncture accidents for thin skin materials with different backing materials. A method will be discussed to assure safety for all of these types of packages

  12. Testing and analysis to determine the shell thickness required to prevent puncture

    International Nuclear Information System (INIS)

    Ammerman, D.J.; Radloff, H.D.; Eifert, E.J.

    1998-05-01

    Type B radioactive material packages are required to withstand a hypothetical puncture accident of a free fall from a height of one meter onto a 15 cm diameter mild steel puncture probe. For many packages it is desirable to have this accident event not result in puncture or tearing of the outer shell of the package. The wall thickness necessary to prevent this has historically been determined by test or the use of empirical relations. This technique generally results in overly conservative designs, but the degree of conservatism is uncertain. The use of modem finite element codes to determine package response to puncture accidents can result in designs that are both safe and economical. The work reported in this paper is aimed at developing a method to analytically determine the wall thickness required to prevent puncture. For designers and regulators to have confidence in this analytical method, however, it must be benchmarked against test results. A series of tests has been conducted with differing shell thicknesses, shell materials of mild steel and stainless steel, and shell backing materials of lead, foam, and air. The results of these tests have been compared with pre-test analytical predictions of the response obtained from the nonlinear transient dynamic finite element program PRONTO-2D. From this comparison it can be seen that the finite element method can accurately predict the response of packages to puncture accidents. This implies that an analytical technique based on the finite element method can be used to design packages having known response and margin of safety against tearing of the outer shell. In addition, the analytical technique can accurately predict the deformed shape of the package following the test. This may be important for subsequent calculations, such as external dose and heat input during a thermal event

  13. C6 plate puncture testing report.

    Energy Technology Data Exchange (ETDEWEB)

    Vangoethem, Douglas J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Cordova, Theresa Elena [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Reu, Phillip L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-04-01

    There are numerous scenarios where critical systems could be subject to penetration by projectiles or fixed objects (e.g., collision, natural disaster, act of terrorism, etc.). It is desired to use computational models to examine these scenarios and make risk-informed decisions; however, modeling of material failure is an active area of research, and new models must be validated with experimental data. The purpose of this report is to document the experimental work performed from FY07 through FY08 on the Campaign Six Plate Puncture project. The goal of this project was to acquire experimental data on the puncture and penetration of metal plates for use in model validation. Of particular interest is the PLH failure model also known as the multilinear line segment model. A significant amount of data that will be useful for the verification and validation of computational models of ductile failure were collected during this project were collected and documented herein; however, much more work remains to be performed, collecting additional experimental data that will further the task of model verification.

  14. Laser puncture therapy of nervous system disorders

    Energy Technology Data Exchange (ETDEWEB)

    Anishchenko, G.; Kochetkov, V.

    1984-08-29

    The authors discuss experience with treatment of nervous system disorders by means of laser-puncture therapy. Commenting on the background of the selection of this type of treatment, they explain that once researchers determined the biological action of laser light on specific nerve receptors of the skin, development of laser apparatus capable of concentrating the beam in the millimeter band was undertaken. The devices that are being used for laser-puncture are said to operate in the red helium-neon band of light. The authors identify beam parameters that have been selected for different groups of acupuncture points of the skin, and the courses of treatment (in seconds of radiation) and their time intervals. They go on to discuss the results of treatment of over 800 patients categorized in a group with disorders of the peripheral nervous system and a second group with disorders of the central nervous system.

  15. Retrograde Intubation in Temporomandibular Joint Ankylosis-A Double Guide Wire Technique

    Directory of Open Access Journals (Sweden)

    Vitha K Dhulkhed

    2008-01-01

    Full Text Available Intubating a patient with temporomandibular joint ankylosis is always a challenge particularly when fibreoptic laryngo-scope is not available. In a 20-year-old male patient we successfully carried out endotracheal intubation with 7 mm portex cuffed PVC tube with the help of two flexible J tipped guide wires. One guide wire was passed into the airway from cricothyroid puncture site and another from subcricoid site. Both were brought out through the nose. The first guide wire was used for retracting the epiglottis and the second as a guide for passing the endotracheal tube.

  16. Standard guide for high-resolution gamma-ray spectrometry of soil samples

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide covers the identification and quantitative determination of gamma-ray emitting radionuclides in soil samples by means of gamma-ray spectrometry. It is applicable to nuclides emitting gamma rays with an approximate energy range of 20 to 2000 keV. For typical gamma-ray spectrometry systems and sample types, activity levels of about 5 Bq (135 pCi) are measured easily for most nuclides, and activity levels as low as 0.1 Bq (2.7 pCi) can be measured for many nuclides. It is not applicable to radionuclides that emit no gamma rays such as the pure beta-emitting radionuclides hydrogen-3, carbon-14, strontium-90, and becquerel quantities of most transuranics. This guide does not address the in situ measurement techniques, where soil is analyzed in place without sampling. Guidance for in situ techniques can be found in Ref (1) and (2). This guide also does not discuss methods for determining lower limits of detection. Such discussions can be found in Refs (3), (4), (5), and (6). 1.2 This guide can be us...

  17. Laparoscopic Removal of a Large Ovarian Mass Utilizing Planned Trocar Puncture

    OpenAIRE

    Stitely, Michael L.

    2012-01-01

    Background: Large cystic ovarian masses pose technical challenges to the laparoscopic surgeon. Removing large, potentially malignant specimens must be done with care to avoid the leakage of cyst fluid into the abdominal cavity. Case: We present the case of a large ovarian cystic mass treated laparoscopically with intentional trocar puncture of the mass to drain and remove the mass. Discussion: Large cystic ovarian masses can be removed laparoscopically with intentional trocar puncture of the ...

  18. Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy

    International Nuclear Information System (INIS)

    Khan, M.F.; Straub, R.; Moghaddam, S.R.; Maataoui, A.; Gurung, J.; Thalhammer, A.; Vogl, T.J.; Jacobi, V.; Wagner, T.O.F.; Ackermann, H.

    2008-01-01

    The influence of various variables on the rate of pneumothorax and intrapulmonal hemorrhage associated with computed tomography (CT)-guided transthoracic needle biopsy of the lung were evaluated retrospectivly. One hundred and thirty-three patients underwent CT guided biopsy of a pulmonary lesion. Two patients were biopsied twice. Variables analyzed were lesion size, lesion location, number of pleural needle passes, lesion margin, length of intrapulmonal biopsy path and puncture time. Eighteen-gauge (18G) cutting needles (Trucut, Somatex, Teltow, Germany) were used for biopsy. Pneumothorax occured in 23 of 135 biopsies (17%). Chest tube placement was required in three out of 23 cases of pneumothorax (2% of all biopsies). Pneumothorax rate was significantly higher when the lesions were located in the lung parenchyma compared with locations at the pleura or chest wall (P < 0.05), but all pneumothorax cases which required chest tube treatment occured in lesions located less than 2 cm from the pleura. Longer puncture time led to an increase in pneumothorax rate (P < 0.05). Thirty-seven (27%) out of 135 biopsies showed perifocal hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage and pneumothorax (P < 0.05). Significantly more hemorrhage occured when the pleura was penetrated twice during the puncture (P < 0.05). Lesion size <4 cm is strongly correlated with higher occurence of perifocal hemorrhage (P < 0.05). Lesion margination showed no significant effect on complication rate. CT-guided biopsy of smaller lesions correlates with a higher bleeding rate. Puncture time should be minimized to reduce pneumothorax rate. Passing the pleura twice significantly increases the risk of hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage as well as pneumothorax. (orig.)

  19. Bilateral subdural hematoma secondary to accidental dural puncture

    Directory of Open Access Journals (Sweden)

    Sofía Ramírez

    2015-07-01

    Full Text Available We report the case of a 25-year-old woman, who received epidural analgesia for labor pain and subsequently presented post-dural puncture headache. Conservative treatment was applied and epidural blood patch was performed. In the absence of clinical improvement and due to changes in the postural component of the headache, a brain imaging test was performed showing a bilateral subdural hematoma.The post-dural puncture headache is relatively common, but the lack of response to established medical treatment as well as the change in its characteristics and the presence of neurological deficit, should raise the suspicion of a subdural hematoma, which although is rare, can be lethal if not diagnosed and treated at the right time. Resumo: Apresentamos o caso clínico de uma paciente de 25 anos de idade, na qual uma técnica peridural foi realizada durante o trabalho de parto e posteriormente apresentou cefaleia com características de cefaleia pós-punção dural. Foi iniciado tratamento conservador e tampão de sangue peridural. Devido a ausência de melhora clínica e à mudança do componente postural da cefaleia, decidiu-se realizar um exame de imagem cerebral que demostrou a presença de hematoma subdural bilateral.A cefaleia pós-punção dural é relativamente frequente, mas a falta de resposta ao tratamento médico instaurado, assim como a mudança em suas características e a presença de foco neurológico, devem levantar a suspeita de presença de um hematoma subdural que, embora infrequente, pode chegar a ser devastador se não for diagnosticado e tratado oportunamente. Keywords: Accidental dural puncture, Epidural analgesia, Post-dural puncture headache, Subdural hematoma, Epidural blood patch, Palavras chave: Dura-Máter, Analgesia epidural, Cefaleia pós-punção dural, Hematoma subdural, Placa de sangue epidural

  20. The effect of second-stage pushing and body mass index on postdural puncture headache.

    Science.gov (United States)

    Franz, Amber M; Jia, Shawn Y; Bahnson, Henry T; Goel, Akash; Habib, Ashraf S

    2017-02-01

    To explore how pushing during labor and body mass index affect the development of postdural puncture headache in parturients who experienced dural puncture with Tuohy needles. Retrospective cohort. Obstetric ward and operating rooms at a university-affiliated hospital. One hundred ninety parturients who had witnessed dural puncture with 17 or 18 gauge Tuohy needles from 1999-2014. Patients were categorized by pushing status and body mass index (kg/m 2 ): nonobese push, women who pushed during labor had increased risk of postdural puncture headache (odds ratio [OR], 2.1 [1.1-4.0]; P=.02), more days of headache (P=.02), and increased epidural blood patch placement (P=.02). Super obese patients were less likely to develop headache compared with nonobese (OR, 0.33 [0.13-0.85]; P=.02), obese (OR, 0.37 [0.14-0.98]; P=.045], and morbidly obese patients (OR, 0.20 [0.05-0.68]; Ppushing (OR, 0.57 [0.29-1.10]; P=.096) and super obesity (OR, 0.41 [0.16-1.02]; P=.056] were no longer significantly associated with reduced risk of postdural puncture headache. Parturients who did not push before delivery and parturients with body mass index ≥50kg/m 2 were less likely to develop postdural puncture headache in a univariate analysis. Similar trends were demonstrated in a multivariate model, but were no longer statistically significant. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Development of puncture resistance tire tube; Nirinsha no taipankusei kojo cube no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Yamagiwa, T; Nakayama, K; Kiyota, S; Tanaka, A [Honda R and D Co. Ltd., Tokyo (Japan); Makisaka, N

    1997-10-01

    A new tire tube with a puncture resistance function was developed. The tube is a two-chamber structure having an air chamber and a liquid chamber, and the liquid chamber at the crown-side half of the tube is filled with an anti-puncture sealant during a manufacturing process. In a market test, it was confirmed that the number of puncture cases were reduced by 90 % in comparison with conventional tire tubes by using the newly developed tube. This paper describes the structure of the tube and the characteristics of the tube rubber, and the manufacturing process and durability of the tube. 3 refs., 17 figs.

  2. [Assertiveness and peripheral intravenous catheters dwell time with ultrasonography-guided insertion in children and adolescents].

    Science.gov (United States)

    Avelar, Ariane Ferreira Machado; Peterlini, Maria Angélica Sorgini; da Pedreira, Mavilde Luz Gonçalves

    2013-06-01

    Randomized controlled trial which aimed to verify whether the use of vascular ultrasound (VUS) increases assertiveness in the use of peripheral venous catheter in children, and the catheter dwell time, when compared to traditional puncture. Data were collected after approval of theethical merit. Children and adolescents undergoing VUS-guided peripheral intravenous (GVUS) or puncture guided by clinical assessment of the venous conditions(CG) were included in the study. Significance level was set at pAssertiveness was found in 73 (71.6%) GVUS catheters and in 84(71.8%) of the CG (p=0.970), and catheter dwell time presented a median of less than one day in both groups (p=0.121), showing nostatistically significant difference. VUS did not significantly influence the results of the dependent variables investigated. ClinicalTrials.govNCT00930254.

  3. Fabrication of Bonding-Type Hollow Microneedle Array by Injection Molding and Evaluation of its Puncture Characteristics

    Science.gov (United States)

    Ogai, Noriyuki; Sugimura, Ryo; Tamaru, Takuya; Takiguchi, Yoshihiro

    A microneedle array which consists from small needles compared to a conventional metal injection needle is expected as a low invasive transdermal medical treatment device, and many fabrication approach have been conducted. In this study, we fabricated plastic hollow microneedle array by a fabrication method based on the combination of injection molding, bonding and assembly techniques. To evaluate puncture characteristics of the fabricated needle, we measured a puncture force to silicone rubber by experimental equipment using loadcell and automatic stage. Furthermore, we propose and demonstrate a new method to measure actual punctured depth from punctured trace on the needle surface modified by O2 plasma treatment.

  4. Rabbit models of cerebral vasospasm established with endovascular puncture

    International Nuclear Information System (INIS)

    Tu Jianfei; Liu Yizhi; Ji Jiansong; Zhao Zhongwei

    2008-01-01

    Objective: To investigate the method of endovascular puncture to establish rabbit models of cerebral vasospasm. Methods: New Zealand white rabbits were divided into 5 groups (12 h, 1 d, 2 d, 3 d and 7 d) randomly, and each group was separated into subarachnoid hemorrhage (SAH) subgroup (n=5) and control subgroup (n=2). cerebral vascular spasm (CVS) models were established after SAH with endovascular puncture. CT scans before and after operation were performed. The internal diameters and the wall thicknesses of posterior communicans artery (PcoA) and basilar artery (BA) were measured with HE stain after the animals were executed. Results: CVS model was successfully eastblished in 35 rabbits (SAH subgroup 25, control subgroup 10), resulting a successful rate of 48.61%. Compared with control subgroup, PcoA and BA showed shrinkage of internal diameters of 43.60% and 51.82% 12 h after SAH, respectively, and the shrinkage appeared as biphasic patterns until the 7th study day with another peaks of 29.32% and 45.19%, respectively. Conclusions: Endovascular puncture is an effective method to establish rabbit of CVS. The death rate of animals can be decreased with the asage of new interventional material and perfection for the details of operation. (authors)

  5. Use of a Collagen-Based Device for Closure of Low Brachial Artery Punctures

    International Nuclear Information System (INIS)

    Belenky, A.; Aranovich, D.; Greif, F.; Bachar, G.; Bartal, G.; Atar, E.

    2007-01-01

    Purpose. To report our experience with the Angioseal vascular closure device for hemostasis of distal brachial artery puncture. Methods. Between September 2003 and August 2005, 64 Angioseal vascular closure devices were inserted in 64 patients (40 men, 24 women; mean age 65 years) immediately after diagnostic or therapeutic arterial angiographies performed through a 5 Fr to 7 Fr sheath via the distal brachial artery. Ultrasound examination of the brachial artery preceded the angiography in all cases and only arteries wider than 4 mm were closed by the Angioseal. In cases of a sonographically evident thin subcutaneous space of the cubital fossa, tissue tumescence, using 1% Lidocaine, was performed prior to the arterial closure. Results. The deployment success rate was 100%. No major complications were encountered; only 2 patients developed puncture site hematoma, and these were followed conservatively. Conclusions. Closure of low brachial artery punctures with the Angioseal is simple and safe. No additional manual compression is required. We recommend its use after brachial artery access interventions, through appropriately wide arteries, to improve early patient ambulation and potentially reduce possible puncture site complications

  6. Development of a new bench for puncturing of irradiated fuel rods in STAR hot laboratory

    Science.gov (United States)

    Petitprez, B.; Silvestre, P.; Valenza, P.; Boulore, A.; David, T.

    2018-01-01

    A new device for puncturing of irradiated fuel rods in commercial power plants has been designed by Fuel Research Department of CEA Cadarache in order to provide experimental data of high precision on fuel pins with various designs. It will replace the current set-up that has been used since 1998 in hot cell 2 of STAR facility with more than 200 rod puncturing experiments. Based on this consistent experimental feedback, the heavy-duty technique of rod perforation by clad punching has been preserved for the new bench. The method of double expansion of rod gases is also retained since it allows upgrading the confidence interval of volumetric results obtained from rod puncturing. Furthermore, many evolutions have been introduced in the new design in order to improve its reliability, to make the maintenance easier by remote handling and to reduce experimental uncertainties. Tightness components have been studied with Sealing Laboratory Maestral at Pierrelatte so as to make them able to work under mixed pressure conditions (from vacuum at 10-5 mbar up to pressure at 50 bars) and to lengthen their lifetime under permanent gamma irradiation in hot cell. Bench ergonomics has been optimized to make its operating by remote handling easier and to secure the critical phases of a puncturing experiment. A high pressure gas line equipped with high precision pressure sensors out of cell can be connected to the bench in cell for calibration purposes. Uncertainty analyses using Monte Carlo calculations have been performed in order to optimize capacity of the different volumes of the apparatus according to volumetric characteristics of the rod to be punctured. At last this device is composed of independent modules which allow puncturing fuel pins out of different geometries (PWR, BWR, VVER). After leak tests of the device and remote handling simulation in a mock-up cell, several punctures of calibrated specimens have been performed in 2016. The bench will be implemented soon in hot

  7. Evaluation of the effects of electron-beam irradiation on the puncture resistance by Lasioderma serricorne in flexible packaging of granola

    International Nuclear Information System (INIS)

    Oliveira, Vitor M.; Alves, Juliana N.; Nogueira, Beatriz R.; Moura, Esperidiana A.B.; Ortiz, Angel V.; Potenza, Marcos R.

    2009-01-01

    Lasioderma serricorne is a beetle that infests stored and industrialized dry foods such as cereal bars, granola, flour and pasta, amongst others, depreciating the products and causing economic losses. It is therefore critical for these products a packaging that presents, in addition to good mechanical, barrier and machinability properties, a good resistance to puncture by insects, in order to prevent the contact and spread of pests in the packaged food. This study evaluates the changes on mechanical properties and puncture resistance by L. serricorne in BOPP/PP structure, used commercially as granola packaging after electron-beam irradiation. The irradiations were performed using a 1.5 MeV electron beam accelerator, dose rate of 11.22 kGy/s, at room temperature in presence of air, doses up to 120 kGy. After irradiation the BOPP/PP samples were subjected to tests of puncture resistance by L. serricorne, tensile strength, friction coefficient, penetration and seal strength. Results showed decreases in the original mechanical properties of the structure according to the radiation doses applied and effective resistance against punctures by L. serricorne (p<0.05). The results indicate that the irradiated and non-irradiated BOPP/PP structure, in the conditions studied in this work, is resistant against L. serricorne, however the decreases observed in the mechanical properties of the irradiated structure may turn it inappropriate for packaging granola. (author)

  8. The closure device for the puncture point of femoral artery: an experiment in vitro

    International Nuclear Information System (INIS)

    Sun Jiantao; Zhang Junfeng; Wu Ke; Wang Yi

    2010-01-01

    Objective: To assess the blocking effects of a new-type closure device for the puncture point of femoral artery in vitro. Methods: An embolic colloidal substance with stable swelling value was embedded in an extracorporeal model which was used as an imitator of femoral artery blood flow velocity. Results: The embolization colloid was not displaced by the imitated blood flow lash, the embolic colloid was firmly attached to the puncture point and no fluid extravasation occurred. Conclusion: This new-type closure device for the puncture point of femoral artery is simple in structure and easy to manipulate with satisfactory blocking results. (authors)

  9. Laparoscopic Removal of a Large Ovarian Mass Utilizing Planned Trocar Puncture

    Science.gov (United States)

    2012-01-01

    Background: Large cystic ovarian masses pose technical challenges to the laparoscopic surgeon. Removing large, potentially malignant specimens must be done with care to avoid the leakage of cyst fluid into the abdominal cavity. Case: We present the case of a large ovarian cystic mass treated laparoscopically with intentional trocar puncture of the mass to drain and remove the mass. Discussion: Large cystic ovarian masses can be removed laparoscopically with intentional trocar puncture of the mass to facilitate removal without leakage of cyst fluid. PMID:22906344

  10. Recent Advances in Thermoplastic Puncture-Healing Polymers

    Science.gov (United States)

    Bogert, Philip B.; Working, Dennis C.; Wise, Kristopher E.; Smith, Janice Y.; Topping, Crystal C.; Britton, Sean M.; Bagby, Paul R.; Siochi, Emilie J.

    2010-01-01

    The motivation for this work is to develop self-healing polymeric materials to enable damage tolerant systems, and to tailor puncture healing for use temperatures and applications. This will be a benefit in environments and conditions where access for manual repair is limited or impossible, or where damage may not be detected.

  11. Diagnosis of Hepatocellular Carcinoma Complicating Liver Cirrhosis: Utility of Repeat Ultrasound-Guided Biopsy after Unsuccessful First Sampling

    International Nuclear Information System (INIS)

    Caturelli, Eugenio; Biasini, Elisabetta; Bartolucci, Francesca; Facciorusso, Domenico; Decembrino, Francesco; Attino, Vito; Bisceglia, Michele

    2002-01-01

    Purpose: To evaluate the utility of a second ultrasound-guided fine-needle biopsy of liver nodules thought to be hepatocellular carcinoma when the original biopsy has failed to provide a reliable diagnosis. Methods: Thirty-seven cirrhotic patients underwent ultrasound-guided fine-needle biopsy of liver nodules that were subsequently diagnosed as hepatocellular carcinoma. Each biopsy involved a single puncture with a 20 G cutting needle, which yielded pathologic material used both for cytologic and histologic studies. In 23 cases (mean diameter of nodules 48 mm) the biopsy furnished exclusively necrotic material (non-diagnostic subgroup); in the other 14 cases (mean diameter 26 mm) the biopsy yielded no neoplastic elements (false-negative subgroup). All 37 nodules were subjected to repeat biopsies performed in the same manner. Results: The repeat biopsies provided a diagnosis of hepatocellular carcinoma in six of the 23 patients from the non-diagnostic subgroup and in seven of the 14 in the false-negative subgroup. Overall, repeat biopsy produced a diagnostic gain of 35.1%. Conclusion: The chance of success with repeat biopsy of hepatocellular carcinoma is limited and may depend to some extent on the characteristics of the lesions (i.e., areas of necrosis in large nodules, well-differentiated cellular populations in small ones)

  12. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, J-M; Polkowski, M; Larghi, A

    2011-01-01

    This article is part of a combined publication that expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about endoscopic ultrasound (EUS)-guided sampling in gastroenterology, including EUS-guided fine needle aspiration (EUS-FNA) and EUS-guided trucut biopsy (EU...

  13. Cone-Beam Computed Tomography-Guided Percutaneous Radiologic Gastrostomy

    International Nuclear Information System (INIS)

    Moehlenbruch, Markus; Nelles, Michael; Thomas, Daniel; Willinek, Winfried; Gerstner, Andreas; Schild, Hans H.; Wilhelm, Kai

    2010-01-01

    The purpose of this study was to investigate the feasibility of a flat-detector C-arm-guided radiographic technique (cone-beam computed tomography [CBCT]) for percutaneous radiologic gastrostomy (PRG) insertion. Eighteen patients (13 men and 5 women; mean age 62 years) in whom percutaneous endoscopic gastrostomy (PEG) had failed underwent CBCT-guided PRG insertion. PEG failure or unsuitability was caused by upper gastrointestinal tract obstruction in all cases. Indications for gastrostomy were esophageal and head and neck malignancies, respectively. Before the PRG procedure, initial C-arm CBCT scans were acquired. Three- and 2-dimensional soft-tissue reconstructions of the epigastrium region were generated on a dedicated workstation. Subsequently, gastropexy was performed with T-fasteners after CBCT-guided puncture of the stomach bubble, followed by insertion of an 14F balloon-retained catheter through a peel-away introducer. Puncture of the stomach bubble and PRG insertion was technically successful in all patients without alteration of the epigastric region. There was no malpositioning of the tube or other major periprocedural complications. In 2 patients, minor complications occurred during the first 30 days of follow-up (PRG malfunction: n = 1; slight infection: n = 1). Late complications, which were mainly tube disturbances, were observed in 2 patients. The mean follow-up time was 212 days. CBCT-guided PRG is a safe, well-tolerated, and successful method of gastrostomy insertion in patients in whom endoscopic gastrostomy is not feasible. CBCT provides detailed imaging of the soft tissue and surrounding structures of the epigastric region in one diagnostic tour and thus significantly improves the planning of PRG procedures.

  14. Comparison of a GPS needle-tracking system, multiplanar imaging and 2D imaging for real-time ultrasound-guided epidural anaesthesia: A randomized, comparative, observer-blinded study on phantoms.

    Science.gov (United States)

    Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier

    2017-04-01

    The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  15. Conformal blocks on a 2-sphere with indistinguishable punctures and implications on black hole entropy

    Directory of Open Access Journals (Sweden)

    Abhishek Majhi

    2016-11-01

    Full Text Available The dimensionality of the Hilbert space of a Chern–Simons theory on a 3-fold, in the presence of Wilson lines carrying spin representations, had been counted by using its link with the Wess–Zumino theory, with level k, on the 2-sphere with points (to be called punctures marked by the piercing of the corresponding Wilson lines and carrying the respective spin representations. It is shown, in the weak coupling (large k limit, the formula decouples into two characteristically distinct parts; one mimics the dimensionality of the Hilbert space of a collection of non-interacting spin systems and the other is an effective overall correction contributed by all the punctures. The exact formula yield from this counting has been shown earlier to have resulted from the consideration of the punctures to be distinguishable. We investigate the same counting problem by considering the punctures to be indistinguishable. Although the full formula remains undiscovered, nonetheless, we are able to impose the relevant statistics for indistinguishable punctures in the approximate formula resulting from the weak coupling limit. As an implication of this counting, in the context of its relation to that of black hole entropy calculation in quantum geometric approach, we are able to show that the logarithmic area correction, with a coefficient of −3/2, that results in this method of entropy calculation, in independent of whether the punctures are distinguishable or not.

  16. The clinical application of percutaneous auto-biopsy of small lung nodular under CT-Guided

    International Nuclear Information System (INIS)

    Zhou Yuanmin; Ye Genxin; Zhang Chenghui; Wang Yu; Chen Wei

    2008-01-01

    Objective: To evaluated the clinical value of technology of petcutaneous auto-biopsy of small lung nodular under CT- Guide. Methods: 44 cases of small single lung nodular were underwent biopsy with 20G auto-biopsy needle under CT guidance. All cases underwent pathological diagnosis. Results: All 44 cases were punctured successfully. 41 cases were succeeded in first puncturation. The success ratio was 93.02%. Other 3 cases needed second puncturation. 39 of 44 cases pathological diagnosis were malignant. Only 1 case could not be diagnosed. 6 patients had lightly pneumatothorax after biopsy. 10 cases had mild pneumonorrhagia after biopsy. 2 of them had haemptysis. All cases had no complication such as infection, needle track implantation. Conclusion: The technology of CT Guidance auto-biopsy of small lung nodular is safe and effective; it has extreme diagnostic ratio and less complication. (authors)

  17. Design of Rate-Compatible Parallel Concatenated Punctured Polar Codes for IR-HARQ Transmission Schemes

    Directory of Open Access Journals (Sweden)

    Jian Jiao

    2017-11-01

    Full Text Available In this paper, we propose a rate-compatible (RC parallel concatenated punctured polar (PCPP codes for incremental redundancy hybrid automatic repeat request (IR-HARQ transmission schemes, which can transmit multiple data blocks over a time-varying channel. The PCPP coding scheme can provide RC polar coding blocks in order to adapt to channel variations. First, we investigate an improved random puncturing (IRP pattern for the PCPP coding scheme due to the code-rate and block length limitations of conventional polar codes. The proposed IRP algorithm only select puncturing bits from the frozen bits set and keep the information bits unchanged during puncturing, which can improve 0.2–1 dB decoding performance more than the existing random puncturing (RP algorithm. Then, we develop a RC IR-HARQ transmission scheme based on PCPP codes. By analyzing the overhead of the previous successful decoded PCPP coding block in our IR-HARQ scheme, the optimal initial code-rate can be determined for each new PCPP coding block over time-varying channels. Simulation results show that the average number of transmissions is about 1.8 times for each PCPP coding block in our RC IR-HARQ scheme with a 2-level PCPP encoding construction, which can reduce half of the average number of transmissions than the existing RC polar coding schemes.

  18. Feasibility of Retrograde Ureteral Contrast Injection to Guide Ultrasonographic Percutaneous Renal Access in the Nondilated Collecting System.

    Science.gov (United States)

    Usawachintachit, Manint; Tzou, David T; Mongan, John; Taguchi, Kazumi; Weinstein, Stefanie; Chi, Thomas

    2017-02-01

    Ultrasound-guided percutaneous nephrolithotomy (PCNL) has become increasingly utilized. Patients with nondilated collecting systems represent a challenge: the target calix is often difficult to visualize. Here we report pilot study results for retrograde ultrasound contrast injection to aid in percutaneous renal access during ultrasound-guided PCNL. From April to July 2016, consecutive patients over the age of 18 years with nondilated collecting systems on preoperative imaging who presented for PCNL were enrolled. B-mode ultrasound imaging was compared with contrast-enhanced mode with simultaneous retrograde injection of Optison™ via an ipsilateral ureteral catheter. Five patients (four males and one female) with renal stones underwent PCNL with retrograde ultrasound contrast injection during the study period. Mean body mass index was 28.3 ± 5.6 kg/m 2 and mean stone size was 24.5 ± 12.0 mm. Under B-mode ultrasound, all patients demonstrated nondilated renal collecting systems that appeared as hyperechoic areas, where it was difficult to identify a target calix for puncture. Retrograde contrast injection facilitated delineation of all renal calices initially difficult to visualize under B-mode ultrasound. Renal puncture was then performed effectively in all cases with a mean puncture time of 55.4 ± 44.8 seconds. All PCNL procedures were completed without intraoperative complications and no adverse events related to ultrasound contrast injection occurred. Retrograde ultrasound contrast injection as an aide for renal puncture during PCNL is a feasible technique. By improving visualization of the collecting system, it facilitates needle placement in challenging patients without hydronephrosis. Future larger scale studies comparing its use to standard ultrasound-guided technique will be required to validate this concept.

  19. Cefalea secundaria a punción dural Headache as a result of dural puncture

    Directory of Open Access Journals (Sweden)

    Ariadna García Rodríguez

    2005-03-01

    Full Text Available Se realizó una revisión bibliográfica sobre cefalea pospunción en el Hospital "Abel Santamaría", de Pinar del Río, en el período comprendido de febrero a junio del 2004, con el objetivo de ampliar los conocimientos de los profesionales de la salud encargados de diagnosticar y tratar esta complicación. La cefalea secundaria a punción dural se debe al escape persistente de LCR (líquido cefalorraquídeo a través del desgarro hecho en la duramadre, causado por la penetración de la aguja; se presenta cuando el paciente adopta la posición erecta y se alivia con el decúbito, característica esta que de no aparecer debe hacer dudar el diagnóstico. La elección de un trocar fino para realizar la punción y la dirección del bisel paralelo a las fibras de la duramadre son los factores determinantes en la profilaxis de la cefalea. Aún existen controversias en cuanto a su tratamiento, pero si hay un consenso unido en que el parche de sangre epidural es el tratamiento definitivo de esta complicación.A review of the most updated literature on dural post-puncture headache was made at Abel Santamaría University Hospital in February - June 2004 aimed at spreading the awareness to health professionals at diagnosing and treating this condition. The headache secondary to dural puncture is caused by the persistent leakage of cerebrospinal fluid through the dura tear because of the needle insertion; it presents when the patient adopts the erect position and it alleviates with the supine position; if this characteristic is not present it may appear some doubts on diagnosis. The selection of a fine trocar for puncture and guiding the bevel parallel to the fibers of dura are the main factors for profilaxis of headache. Its treatment is controversial, but it does exist a consensus in that the epidural blood patch is the definitive treatment for this condition.

  20. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    International Nuclear Information System (INIS)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra; Muche, Rainer; Krueger, Stefan

    2008-01-01

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  1. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    Energy Technology Data Exchange (ETDEWEB)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra [University of Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany); Muche, Rainer [University of Ulm, Institute of Biometrics, Ulm (Germany); Krueger, Stefan [University of Ulm, Department of Internal Medicine, Ulm (Germany)

    2008-06-15

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n = 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P = 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  2. Heme oxygenase-1 modulates degeneration of the intervertebral disc after puncture in Bach 1 deficient mice.

    Science.gov (United States)

    Ohta, Ryo; Tanaka, Nobuhiro; Nakanishi, Kazuyoshi; Kamei, Naosuke; Nakamae, Toshio; Izumi, Bunichiro; Fujioka, Yuki; Ochi, Mitsuo

    2012-09-01

    Intervertebral disc degeneration is considered to be a major feature of low back pain. Furthermore, oxidative stress has been shown to be an important factor in degenerative diseases such as osteoarthritis and is considered a cause of intervertebral disc degeneration. The purpose of this study was to clarify the correlation between oxidative stress and intervertebral disc degeneration using Broad complex-Tramtrack-Bric-a-brac and cap'n'collar homology 1 deficient (Bach 1-/-) mice which highly express heme oxygenase-1 (HO-1). HO-1 protects cells from oxidative stress. Caudal discs of 12-week-old and 1-year-old mice were evaluated as age-related models. Each group and period, 5 mice (a total of 20 mice, a total of 20 discs) were evaluated as age-related model. C9-C10 caudal discs in 12-week-old Bach 1-/- and wild-type mice were punctured using a 29-gauge needle as annulus puncture model. Each group and period, 5 mice (a total of 60 mice, a total of 60 discs) were evaluated. The progress of disc degeneration was evaluated at pre-puncture, 1, 2, 4, 8 and 12 weeks post-puncture. Radiographic, histologic and immunohistologic analysis were performed to compare between Bach 1-/- and wild-type mice. In the age-related model, there were no significant differences between Bach 1-/- and wild-type mice radiologically and histologically. However, in the annulus puncture model, histological scoring revealed significant difference at 8 and 12 weeks post-puncture. The number of HO-1 positive cells was significantly greater in Bach 1-/- mice at every period. The apoptosis rate was significantly lower at 1 and 2 weeks post-puncture in Bach 1-/- mice. Oxidative stress prevention may avoid the degenerative process of the intervertebral disc after puncture, reducing the number of apoptosis cells. High HO-1 expression may also inhibit oxidative stress and delay the process of intervertebral disc degeneration.

  3. Design and application of model for training ultrasound-guided vascular cannulation in pediatric patients.

    Science.gov (United States)

    Pérez-Quevedo, O; López-Álvarez, J M; Limiñana-Cañal, J M; Loro-Ferrer, J F

    2016-01-01

    Central vascular cannulation is not a risk-free procedure, especially in pediatric patients. Newborn and infants are small and low-weighted, their vascular structures have high mobility because of tissue laxity and their vessels are superficial and with small diameter. These characteristics, together with the natural anatomical variability and poor collaboration of small children, make this technique more difficult to apply. Therefore, ultrasound imaging is increasingly being used to locate vessels and guide vascular access in this population. (a) To present a model that simulates the vascular system for training ultrasound-guided vascular access in pediatrics patients; (b) to ultrasound-guided vascular cannulation in the model. The model consisted of two components: (a) muscular component: avian muscle, (b) vascular component: elastic tube-like structure filled with fluid. 864 ecoguided punctures was realized in the model at different vessel depth and gauge measures were simulated, for two medical operators with different degree of experience. The average depth and diameter of vessel cannulated were 1.16 (0.42)cm and 0.43 (0.1)cm, respectively. The average number of attempts was of 1.22 (0.62). The percentage of visualization of the needle was 74%. The most frequent maneuver used for the correct location, was the modification of the angle of the needle and the relocation of the guidewire in 24% of the cases. The average time for the correct cannulations was 41 (35.8)s. The more frequent complications were the vascular perforation (11.9%) and the correct vascular puncture without possibility of introducing the guidewire (1.2%). The rate of success was 96%. The model simulates the anatomy (vascular and muscular structures) of a pediatric patient. It is cheap models, easily reproducible and a useful tool for training in ultrasound-guided puncture and cannulation. Copyright © 2015 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  4. The learning curve for access creation in solo ultrasonography-guided percutaneous nephrolithotomy and the associated skills.

    Science.gov (United States)

    Yu, Weimin; Rao, Ting; Li, Xing; Ruan, Yuan; Yuan, Run; Li, Chenglong; Li, Haoyong; Cheng, Fan

    2017-03-01

    The aim of the current trial was to evaluate the learning curve of access creation through solo ultrasonography (US)-guided percutaneous nephrolithotomy (PCNL), and clarify the technical details of the procedure. We evaluated the first 240 solo US-guided PCNLs performed by one surgeon at our institution. The data including the puncture procedure, access characteristics, access-related complications and stone-free rates were assessed in four sequential groups. The puncture duration and number of times decreased from a mean of 4.4 min and 2.1 times for the first 60 patients to 1.3 min and 1.2 times for the last 60 patients. There was a significant decrease from 3.7 min and 1.8 times for the 61th-120th patients to 1.5 min and 1.3 times for the 121th-180th patients. All of the access-related severe bleeding appeared in the first 120 patients, while perforations only occurred in the first 60 patients. The stone-free rates were 68.3, 83.3, 90.0, and 93.3% for the four sequential groups. The increase in experience lead to an improvement in the puncture duration and times, which accompany with better stone-free rates and lower complications. We propose that 60 operations are sufficient to gain competency, and a cutoff point of 120 operations will allow the surgeon to achieve excellence in the solo US-guided PCNL.

  5. Pleural puncture with thoracic epidural: A rare complication?

    Directory of Open Access Journals (Sweden)

    Rachna Wadhwa

    2011-01-01

    Full Text Available Freedom from pain has almost developed to be a fundamental human right. Providing pain relief via epidural catheters in thoracic and upper abdominal surgeries is widely accepted. Pain relief through this technique not only provides continuous analgesia but also reduces post-operative pulmonary complications and also hastens recovery. But being a blind procedure it is accompanied by certain complications. Hypotension, dura puncture, high epidural, total spinal, epidural haematoma, spinal cord injury and infection are some of the documented side effects of epidural block. There are case reports eliciting neurological complications, catheter site infections, paresthesias, radicular symptoms and worsening of previous neurological conditions. Few technical problems related to breakage of epidural catheter are also mentioned in the literature. The patient had no sequelae on long term follow up even when a portion of catheter was retained. We present a case report where epidural catheter punctured pleura in a patient undergoing thoracotomy for carcinoma oesophagus.

  6. Subcutaneous Emphysema Induced by Cryotherapy: A Complication due to Previous Punctures

    Directory of Open Access Journals (Sweden)

    Jared Martínez-Coronado

    2015-01-01

    Full Text Available Cryosurgery is a common therapeutic modality used in dermatology; therefore we must be aware of its possible adverse effects. We report a case of a patient with subcutaneous emphysema which occurred following the application of cryotherapy after multiple punctures of local anesthetic and intralesional steroids in a chest keloid scar. Despite the fact that this condition was gradually resolved after expectant observation, we warn about this complication when sprayed cryotherapy is preceded by multiple punctures on cutaneous lesions above bony surfaces. In similar settings, cryotherapy must be first administered or a cotton-tip applicator should be used.

  7. Electromagnetic Navigational Bronchoscopy versus CT-guided Percutaneous Sampling of Peripheral Indeterminate Pulmonary Nodules: A Cohort Study.

    Science.gov (United States)

    Bhatt, Kavita M; Tandon, Yasmeen K; Graham, Ruffin; Lau, Charles T; Lempel, Jason K; Azok, Joseph T; Mazzone, Peter J; Schneider, Erika; Obuchowski, Nancy A; Bolen, Michael A

    2018-03-01

    Purpose To compare the diagnostic yield and complication rates of electromagnetic navigational bronchoscopic (ENB)-guided and computed tomography (CT)-guided percutaneous tissue sampling of lung nodules. Materials and Methods Retrospectively identified were 149 patients sampled percutaneously with CT guidance and 146 patients who underwent ENB with transbronchial biopsy of a lung lesion between 2013 and 2015. Clinical data, incidence of complications, and nodule pathologic analyses were assessed through electronic medical record review. Lung nodule characteristics were reviewed through direct image analysis. Molecular marker studies and pathologic analyses from surgical excision were reviewed when available. Multiple-variable logistic regression models were built to compare the diagnostic yield and complication rates for each method and for different patient and disease characteristics. Results CT-guided sampling was more likely to be diagnostic than ENB-guided biopsy (86.0% [129 of 150] vs 66.0% [99 of 150], respectively), and this difference remained significant even after adjustments were made for patient and nodule characteristics (P guided sampling (P guided sampling, 88.9% [32 of 36]; CT-guided sampling, 82.0% [41 of 50]). The two groups had similar rates of major complications (symptomatic hemorrhage, P > .999; pneumothorax requiring chest tube and/or admission, P = .417). Conclusion CT-guided transthoracic biopsy provided higher diagnostic yield in the assessment of peripheral pulmonary nodules than navigational bronchoscopy with a similar rate of clinically relevant complications. © RSNA, 2017 Online supplemental material is available for this article.

  8. Computer tomography urography assisted real-time ultrasound-guided percutaneous nephrolithotomy on renal calculus.

    Science.gov (United States)

    Fang, You-Qiang; Wu, Jie-Ying; Li, Teng-Cheng; Zheng, Hao-Feng; Liang, Guan-Can; Chen, Yan-Xiong; Hong, Xiao-Bin; Cai, Wei-Zhong; Zang, Zhi-Jun; Di, Jin-Ming

    2017-06-01

    This study aimed to assess the role of pre-designed route on computer tomography urography (CTU) in the ultrasound-guided percutaneous nephrolithotomy (PCNL) for renal calculus.From August 2013 to May 2016, a total of 100 patients diagnosed with complex renal calculus in our hospital were randomly divided into CTU group and control group (without CTU assistance). CTU was used to design a rational route for puncturing in CTU group. Ultrasound was used in both groups to establish a working trace in the operation areas. Patients' perioperative parameters and postoperative complications were recorded.All operations were successfully performed, without transferring to open surgery. Time of channel establishment in CTU group (6.5 ± 4.3 minutes) was shorter than the control group (10.0 ± 6.7 minutes) (P = .002). In addition, there was shorter operation time, lower rates of blood transfusion, secondary operation, and less establishing channels. The incidence of postoperative complications including residual stones, sepsis, severe hemorrhage, and perirenal hematoma was lower in CTU group than in control group.Pre-designing puncture route on CTU images would improve the puncturing accuracy, lessen establishing channels as well as improve the security in the ultrasound-guided PCNL for complex renal calculus, but at the cost of increased radiation exposure.

  9. Neuronavigator-guided percutaneous radiofrequency thermocoagulation in the treatment of trigeminal neuralgia.

    Science.gov (United States)

    Zhang, W C; Zhong, W X; Li, S T; Zheng, X S; Yang, M; Shi, J

    2012-03-01

    Although radiofrequency thermocoagulation is considered as a primary treatment for most patients with trigeminal neuralgia, neuronavigator-guided percutaneous radiofrequency thermocoagulation has been rarely reported. The object of this study was to assess the clinical value of neuronavigator-guided percutaneous radiofrequency thermocoagulation in the treatment of trigeminal neuralgia. The radiofrequency thermocoagulation was performed in 100 cases of trigeminal neuralgia. The patients were positioned supine or sitting, under Hartel's technique (reported by Sweet and Wepsic J Neurosurg 40:143-156, 1974), by anterior lateral facial approaches. The Gasserian ganglions were acupunctured, assisted by intraoperative CT scanning (3-digital reconstruction) and electrophysiology in order to accurately locate target. The needles located in oval foramen at the first puncture, the direction and position could be defined according to the electrophysiology examination. The pain alleviated immediately after operation. There occurred no serious complication and other nerve injury in all patients despite face numbness only. 3D-CT and electrophysiology Gasser's ganglion locations can raise the success rate of puncture, enhance the safety and reduce the incidence of complication, showing high academic value and its promising future.

  10. The influence of punctural millimeter wave therapy on clinical presentation of patients with essential hypertention

    Directory of Open Access Journals (Sweden)

    Kotenko К.V.

    2013-12-01

    Full Text Available Aim: to estimate the influence of punctural millimeter wave therapy on clinical presentation. Material and methods. This study includes 102 patients with essential hypertension the I and II stage. Patients were divided into three equal groups depending on the method of treatment: some of them received procedures of punctural millimeter wave therapy, some of them received these procedures as the "placebo" and those who had not received specified procedures. Dynamics of clinical symptomatology and condition of eye bottom vessels was estimated. It was shown that addition of punctural millimeter wave therapy in complex therapy of patients with essential hypertension promotes the expressed regress of clinical symptomatology and state normalization the retinal vessels at these patients. Results. Addition of punctural millimeter wave therapy into the complex therapy was shown to lead to pronounced regress of clinical symptoms. Conclusion. The received results allow to recommend this method to be used in clinical practice for treating patients with essential hypertension.

  11. Routine Cranial Computed Tomography before Lumbar Puncture in ...

    African Journals Online (AJOL)

    Background: Current international guidelines recommend that a cranial computed tomography (CT) be performed on all HIV-positive patients presenting with new onset seizures, before a lumbar puncture (LP) is performed. In the South African setting, however this delay could be life threatening. The present study sought to ...

  12. The effects of needle deformation during lumbar puncture

    Directory of Open Access Journals (Sweden)

    Hasan Hüseyin Özdemir

    2015-01-01

    Full Text Available Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP. Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1% of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3% of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%. Forty-seven (41.5% patients experienced post lumbar puncture headache (PLPH and 13 (11.5% patients experienced intracranial hypotension (IH. No statistically significant correlation between the degree of deflection and headache was found (P > 0.05. Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH.

  13. The effects of needle deformation during lumbar puncture

    Science.gov (United States)

    Özdemir, Hasan Hüseyin; Demir, Caner F.; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH. PMID:25883480

  14. Quasiequilibrium states of black hole-neutron star binaries in the moving-puncture framework

    International Nuclear Information System (INIS)

    Kyutoku, Koutarou; Shibata, Masaru; Taniguchi, Keisuke

    2009-01-01

    General relativistic quasiequilibrium states of black hole-neutron star binaries are computed in the moving-puncture framework. We propose three conditions for determining the quasiequilibrium states and compare the numerical results with those obtained in the excision framework. We find that the results obtained in the moving-puncture framework agree with those in the excision framework and with those in the third post-Newtonian approximation for the cases that (i) the mass ratio of the binary is close to unity irrespective of the orbital separation, and (ii) the orbital separation is large enough (m 0 Ω 0 and Ω are the total mass and the orbital angular velocity, respectively) irrespective of the mass ratio. For m 0 Ω > or approx. 0.03, both of the results in the moving-puncture and excision frameworks deviate, more or less, from those in the third post-Newtonian approximation. Thus the numerical results do not provide a quasicircular state, rather they seem to have a non-negligible eccentricity of order 0.01-0.1. We show by numerical simulation that a method in the moving-puncture framework can provide approximately quasicircular states in which the eccentricity is by a factor of ∼2 smaller than those in quasiequilibrium given by other approaches.

  15. Effectiveness of sublingual nitroglycerin before puncture compared with conventional intra-arterial nitroglycerin in transradial procedures: a randomized trial

    Energy Technology Data Exchange (ETDEWEB)

    Turan, Burak, E-mail: drburakturan@gmail.com; Daşlı, Tolga; Erkol, Ayhan; Erden, İsmail

    2015-10-15

    Aim: Sublingual (SL) nitroglycerin administered before radial artery puncture can improve cannulation success and decrease the incidence of radial artery spasm (RAS) compared with intra-arterial (IA) nitroglycerin in transradial procedures. Methods: Patients undergoing diagnostic transradial angiography were randomized to IA (200 mcg) or SL (400 mcg) nitroglycerin. Primary endpoints were puncture time and puncture attempts. Secondary endpoint was the incidence of RAS. Results: Total of 101 participants (mean age 60 ± 11 years, 53% male) were randomized (51 in IA and 50 in SL groups). Puncture time (50 [36–75] vs 50 [35–90] sec), puncture attempts (1.18 ± 0.48 vs 1.20 ± 0.49), multiple punctures (13.7 vs 16.0%) and RAS (19.6 vs 24.0%) were not statistically different between IA vs SL groups respectively. A composite endpoint of all adverse events related to transradial angiography (multiple punctures, RAS, access site crossover, hypotension/bradycardia associated with nitroglycerin and radial artery occlusion) was very similar in IA vs SL groups (39 vs 40%, respectively). However puncture time was significantly longer with SL nitroglycerin in patients < 1.65 m height (47 [36–66] vs 63 [41–110] sec, p = 0.042). Multiple punctures seemed higher with SL nitroglycerin in patients with diabetes (0 vs 30%, p = 0.028) or in patients < 1.65 m height (7.4 vs 25%, p = 0.085). Likewise, RAS with SL nitroglycerin seemed more frequent in smokers compared to IA nitroglycerin (0 vs 27%, p = 0.089). Conclusions: SL nitroglycerin was not different from IA nitroglycerin in terms of efficiency and safety in overall study population. However it may be inferior to IA nitroglycerin in certain subgroups (shorter individuals, diabetics and smokers). - Highlights: • Improvement in radial artery puncture time and success with subcutaneous nitrate was reported. • Giving nitrate sublingually may have vasodilation along entire length of radial artery and may prevent RAS

  16. Visual Sample Plan Version 7.0 User's Guide

    Energy Technology Data Exchange (ETDEWEB)

    Matzke, Brett D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Newburn, Lisa LN [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hathaway, John E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bramer, Lisa M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wilson, John E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dowson, Scott T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sego, Landon H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Pulsipher, Brent A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-03-01

    User's guide for VSP 7.0 This user's guide describes Visual Sample Plan (VSP) Version 7.0 and provides instructions for using the software. VSP selects the appropriate number and location of environmental samples to ensure that the results of statistical tests performed to provide input to risk decisions have the required confidence and performance. VSP Version 7.0 provides sample-size equations or algorithms needed by specific statistical tests appropriate for specific environmental sampling objectives. It also provides data quality assessment and statistical analysis functions to support evaluation of the data and determine whether the data support decisions regarding sites suspected of contamination. The easy-to-use program is highly visual and graphic. VSP runs on personal computers with Microsoft Windows operating systems (XP, Vista, Windows 7, and Windows 8). Designed primarily for project managers and users without expertise in statistics, VSP is applicable to two- and three-dimensional populations to be sampled (e.g., rooms and buildings, surface soil, a defined layer of subsurface soil, water bodies, and other similar applications) for studies of environmental quality. VSP is also applicable for designing sampling plans for assessing chem/rad/bio threat and hazard identification within rooms and buildings, and for designing geophysical surveys for unexploded ordnance (UXO) identification.

  17. Emergency medical technician-performed point-of-care blood analysis using the capillary blood obtained from skin puncture.

    Science.gov (United States)

    Kim, Changsun; Kim, Hansol

    2017-12-09

    Comparing a point-of-care (POC) test using the capillary blood obtained from skin puncture with conventional laboratory tests. In this study, which was conducted at the emergency department of a tertiary care hospital in April-July 2017, 232 patients were enrolled, and three types of blood samples (capillary blood from skin puncture, arterial and venous blood from blood vessel puncture) were simultaneously collected. Each blood sample was analyzed using a POC analyzer (epoc® system, USA), an arterial blood gas analyzer (pHOx®Ultra, Nova biomedical, USA) and venous blood analyzers (AU5800, DxH2401, Beckman Coulter, USA). Twelve parameters were compared between the epoc and reference analyzers, with an equivalence test, Bland-Altman plot analysis and linear regression employed to show the agreement or correlation between the two methods. The pH, HCO 3 , Ca 2+ , Na + , K + , Cl - , glucose, Hb and Hct measured by the epoc were equivalent to the reference values (95% confidence interval of mean difference within the range of the agreement target) with clinically inconsequential mean differences and narrow limits of agreement. All of them, except pH, had clinically acceptable agreements between the two methods (results within target value ≥80%). Of the remaining three parameters (pCO 2, pO 2 and lactate), the epoc pCO 2 and lactate values were highly correlated with the reference device values, whereas pO 2 was not. (pCO 2 : R 2 =0.824, y=-1.411+0.877·x; lactate: R 2 =0.902, y=-0.544+0.966·x; pO 2 : R 2 =0.037, y=61.6+0.431·x). Most parameters, except only pO 2 , measured by the epoc were equivalent to or correlated with those from the reference method. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. EUS-guided recanalization of complete gastrointestinal strictures

    Directory of Open Access Journals (Sweden)

    Miguel Martínez-Guillén

    Full Text Available Background and aim: Complete gastrointestinal strictures are a technically demanding problem. In this setting, an anterograde technique is associated with a high risk of complications and a combined anterograde-retrograde technique requires a prior ostomy. Our aim was to assess the outcome of a first case series for the management of complete gastrointestinal strictures using endoscopic ultrasound (EUS-guided puncture as a novel endoscopic approach. Patients and methods: This retrospective case-series describes four cases that were referred for treatment of complete benign gastrointestinal strictures, three upper and one lower. Recanalization was attempted with EUS-guided puncture using a 22G or 19G needle and contrast filling was visualized by fluoroscopy. Afterwards, a cystotome and/or a dilator balloon were used under endoscopic and fluoroscopic guidance. A fully covered metal stent was placed in two cases, keeping the strictures open in order to prevent another stricture. Feasibility, adverse events, efficacy and the number of dilations required after recanalization were evaluated. Results: Technical and clinical success was achieved in three of the four cases (75%. A first dilation was performed using a dilator balloon in all successful cases and fully covered metal stents were used in two cases. These patients underwent a consecutive number of balloon dilatations (range 1-4 and all three were able to eat a soft diet. No adverse events were related to the EUS-guided approach. In the failed case with a long stricture (> 3 cm, an endoscopic rendezvous technique was attempted which caused a pneumothorax requiring a chest tube placement. Conclusion: EUS-guided recanalization, as a first approach in the treatment of complete digestive stricture, is a feasible and promising procedure that can help to avoid major surgery.

  19. Correlation of Descriptive Analysis and Instrumental Puncture Testing of Watermelon Cultivars.

    Science.gov (United States)

    Shiu, J W; Slaughter, D C; Boyden, L E; Barrett, D M

    2016-06-01

    The textural properties of 5 seedless watermelon cultivars were assessed by descriptive analysis and the standard puncture test using a hollow probe with increased shearing properties. The use of descriptive analysis methodology was an effective means of quantifying watermelon sensory texture profiles for characterizing specific cultivars' characteristics. Of the 10 cultivars screened, 71% of the variation in the sensory attributes was measured using the 1st 2 principal components. Pairwise correlation of the hollow puncture probe and sensory parameters determined that initial slope, maximum force, and work after maximum force measurements all correlated well to the sensory attributes crisp and firm. These findings confirm that maximum force correlates well with not only firmness in watermelon, but crispness as well. The initial slope parameter also captures the sensory crispness of watermelon, but is not as practical to measure in the field as maximum force. The work after maximum force parameter is thought to reflect cellular arrangement and membrane integrity that in turn impact sensory firmness and crispness. Watermelon cultivar types were correctly predicted by puncture test measurements in heart tissue 87% of the time, although descriptive analysis was correct 54% of the time. © 2016 Institute of Food Technologists®

  20. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, M.; Yasunaga, T.; Konishi, K. [Kyushu University, Department of Advanced Medical Initiatives, Faculty of Medical Sciences, Fukuoka (Japan); Tanoue, K.; Ieiri, S. [Kyushu University Hospital, Department of Advanced Medicine and Innovative Technology, Fukuoka (Japan); Kishi, K. [Hitachi Ltd, Mechanical Engineering Research Laboratory, Hitachinaka-Shi, Ibaraki (Japan); Nakamoto, H. [Hitachi Medical Corporation, Application Development Office, Kashiwa-Shi, Chiba (Japan); Ikeda, D. [Mizuho Ikakogyo Co. Ltd, Tokyo (Japan); Sakuma, I. [The University of Tokyo, Graduate School of Engineering, Bunkyo-Ku, Tokyo (Japan); Fujie, M. [Waseda University, Graduate School of Science and Engineering, Shinjuku-Ku, Tokyo (Japan); Dohi, T. [The University of Tokyo, Graduate School of Information Science and Technology, Bunkyo-Ku, Tokyo (Japan)

    2008-04-15

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  1. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    International Nuclear Information System (INIS)

    Hashizume, M.; Yasunaga, T.; Konishi, K.; Tanoue, K.; Ieiri, S.; Kishi, K.; Nakamoto, H.; Ikeda, D.; Sakuma, I.; Fujie, M.; Dohi, T.

    2008-01-01

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  2. [The relationship between angle of puncture and distribution of bone cement of unilateral percutaneous kyphoplasty for the treatment of thoracolumbar compression fractures].

    Science.gov (United States)

    Wang, Xiang-fu; Fan, You-fu; Shi, Rui-fang; Deng, Qiang; Li, Zhong-feng

    2015-08-01

    To explore the relationship of bone cement distribution and the puncture angle in the treatment of thoracolumbar compression fractures with unilateral percutaneous kyphoplasty (PKP). The clinical data of 37 patients with thoracolumbar osteoporotic compression fractures underwent PKP between January 2013 to March 2014 were retrospectively analyzed, all punctures were performed unilaterally. There were 6 males, aged from 65 to 78 years old with an average of (71.83 ± 6.15) years; and 31 females, aged from 57 to 89 years old with an average of (71.06 ± 7.89) years. Imaging data were analyzed and puncture angle and puncture point were measured before operation. According to the measured data, the puncture were performeds during the operation. Distribution area of bone cement were calculated by X-rays data after operation. The effect of bone cement distribution on suitable puncture angle was analyzed; VAS score was used to evaluate the clinical effects. The puncture angle of thoracic vertebrae in T8-T12 was from 28° to 33° with an average 30.4°; and the puncture angle of lumbar vertebrae in L1-L5 was from 28° to 35° with an average of 31.3°. Postoperative X-rays showed the area ratios of bilateral bone cement was 0.97 ± 0.15. Bilateral diffuse area were basic equal. Postoperative VAS score decreased significantly (1.89 ± 1.29 vs 7.03 ± 1.42). Through measure imaging data before operation with PKP,the puncture point and entry point can be confirmed. According the measured data to puncture during operation, unilateral puncture can reach the distribution effect of the bilateral puncture in the treatment of thoracolumbar compression fractures.

  3. A comparison of various methods of blood sampling in mice and rats: Effects on animal welfare

    DEFF Research Database (Denmark)

    Harikrishnan, Vs; Hansen, Axel K; Abelson, Klas Sp

    2018-01-01

    -puncture activity and anxiety levels of rats and mice were measured using an elevated plus maze test and an open field test. Stress levels 24 h post-puncture were assessed by analysing faecal corticosteroid metabolites. Sucrose intake and faecal corticosteroid levels were not affected by the blood sampling...... procedures. Rats showed reduced activity in the open field test and an increased level of anxiety in the elevated plus maze test following retrobulbar plexus puncture and isoflurane anaesthesia. In mice, nest building activity was affected in all the groups compared with the control group, except for animals...... subjected to facial vein puncture. Retrobulbar sinus puncture, tail vein puncture and sublingual puncture in mice resulted in reduced activity and increased anxiety. We conclude that, of the tested methods, puncture of the tail vein and the sublingual vein have the least adverse effects in rats, whereas...

  4. There is room for improvement in the prevention and treatment of headache after lumbar puncture

    DEFF Research Database (Denmark)

    Stendell, Line; Fomsgaard, Jonna S; Olsen, Karsten S

    2012-01-01

    The incidence of post dural puncture headache (PDPH) after lumbar puncture (LP) can be reduced from 36% to 0-9% by use of an atraumatic needle size 24 gauge (G)/0.56 mm rather than a traumatic needle size 22 G/0.7 mm. The evidence supporting some of the prophylactic and therapeutically treatments...

  5. A new multiple noncontinuous puncture (pointage technique for corneal tattooing

    Directory of Open Access Journals (Sweden)

    Jin Hyoung Park

    2015-10-01

    Full Text Available AIM:To assess the safety and cosmetic efficacy of a new multiple noncontinuous transepithelial puncture technique for tattooing a decompensated cornea.METHODS:It was anon-comparative clinical case series study.The study examines 33 eyes in 33 patients with total corneal opacity due to corneal decompensation, which developed following intraocular surgery.Corneal tattooing was performed using the multiple noncontinuous transepithelial puncture technique (i.e. pointage. The safety of this new surgical strategy was assessed by occurrence of adverse events for the follow-up period. The cosmetic efficacy was determined by the patient’s cosmetic satisfaction and independent observer’s opinion about patient appearance.RESULTS:Seven women and 26 men were included in the study. The mean age was 46.4±17.5y (range:7-67. In total, 30 of 33 patients (91% reported cosmetic satisfaction within the follow-up period. Only 3 patients (9% required additional tattooing due to cosmetic unsatisfaction. Cosmetic outcomes were analyzed and classified as excellent or good in 13 (39% and 17 (52% patients, respectively. No serious adverse events developed, except delayed epithelial healing in 3 cases.CONCLUSION:The cosmetic outcomes of the multiple noncontinuous transepithelial puncture technique for corneal tattooing were good. The safety of this method is higher than conventional procedures. This new procedure also provides improved cost-effectiveness and safety over current corneal tattooing techniques.

  6. Results and complications of CT-guided biopsy with CT fluoroscopy

    International Nuclear Information System (INIS)

    Saika, Yoshinori; Ogura, Yasuharu; Doi, Kenji; Misaki, Toshimasa; Shimizu, Masashi; Narabayashi, Isamu

    2002-01-01

    We studied the results and complications of CT-guided biopsy with CT fluoroscopy performed 66 lesions in 64 patients from March 1999 to February 2001. In addition to the conventional procedure of CT-guided biopsy, we use CT fluoroscopy for confirmation of the location of the tip of the biopsy needle and the accurate contact, in some cases, at the time of puncturing. Examination results showed malignancy in 36 lesions and benign findings in 30 lesions. The sensitivity was 85.7%, specificity was 100.0%, and accuracy was 90.9%. Pneumothorax occurred in 20 out of 64 patients (31.3%). In a study on 26 small lesions (≤2 cm) in 25 patients, the sensitivity was 81.8%, specificity was 100.0%, accuracy was 92.3%. Pneumothorax occurred in 12 out of 25 patients (48.0%), more frequently than in patients with large lesions. In a study on 6 false negative cases, they tended to be intrapulmonary on location, small in diameter, and far from the skin puncture point. Examination results were satisfactory, especially in terms of accuracy in small lesions (≤2 cm). However, when the lesions were small, pneumothorax occurred frequently (48.0%). (author)

  7. [Examination of the optimal midazolam dose required for loss of puncture memory at the time of spinal anesthesia].

    Science.gov (United States)

    Boku, Aiji; Koyama, Shinichi; Kishimoto, Naotaka; Nakatani, Keiji; Kurita, Satoshi; Nagata, Noboru; Niwa, Hitoshi

    2011-08-01

    We examined midazolam ED50 according to age that was necessary for loss of puncture memory at the time of spinal anesthesia and determined whether we could estimate the presence of puncture memory from the degree of sedation after midazolam administration. We enrolled patients with ASA PS 1 or 2 and patients from 50 to 80 years of age who had been planned for surgery with spinal anesthesia. We divided the patients into groups according to their age--50s, 60s, and 70s as L, M, and H groups, respectively. We evaluated the degree of sedation with six phases of scores after intravenous administration of midazolam and spinal anesthesia was performed. The midazolam dose was based on the ups and downs method. The midazolam ED50s required for the loss of puncture memory in groups L, M, and H were 0.043, 0.035, and 0.026 mg x kg(-1), respectively. We estimated the association between the sedation degree score after midazolam administration and the puncture memory from ROC curve, but AUC was 0.56 for all cases. The midazolam ED50 required for the loss of puncture memory decreased with age but it was difficult to estimate puncture memory from the degree of sedation.

  8. The optical "Veress-needle"--initial puncture with a minioptic.

    Science.gov (United States)

    Schaller, G; Kuenkel, M; Manegold, B C

    1995-02-01

    Laparoscopic access is a necessary part of minimally invasive surgery. The double blind puncture with Veress-needle and trocar can cause lethal complications such as bowel injury, bleeding and gas-embolisation. Some authors have reported alternative techniques for laparoscopic abdominal access. Because no blind procedure can absolutely prevent injury, permanent visual control of perforated tissue layers as in open surgery should be achieved to prevent possible injury at an early stage. Previously described procedures could not fulfil all requirements to comply with this ideal, i.e. permanent visual control of abdominal wall penetration prior to establishment of pneumoperitoneum and trocar insertion without further possible damage. We designed a 2 mm fibreglass optic 250 mm in length that is inserted into a suitable cannula. Special construction allows rinsing through the cannula to clear the vision and to open spaces in the puncture track by water dissection. After incision of the skin, all layers of the abdominal wall can be visualised, including blood vessels and internal surfaces. Once the abdominal cavity is reached, the needle tip is retracted and a two-step dilation allows the trocar to be introduced via the puncture track. Only then does insufflation begin. The fibreglass optic-equipped safety needle was used for visually controlled access in 184 laparoscopic surgical procedures. After a period of training, all layers of the abdominal wall could be recognised exactly. In two patients with dense adhesions, perforation of the small bowel was diagnosed immediately by endoscopic viewing. The small injury needed no treatment, and the intended procedure was completed laparoscopically.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. About the diagnostic accuracy rate of fluoroscopy-guided fine needle puncture

    International Nuclear Information System (INIS)

    Wernecke, K.; Teske, H.J.

    1983-01-01

    Percutaneous fine-needle biopsies guided by X-ray were performed in 100 patients utilizing the Nordenstroem canule. All cases have now been clinically controlled for at least 14 and up to 30 months. The follow up allowed further conclusions due to the dignity of histologically negative biopsies. Positive results on malignant lesions were obtained in 74% of cases. Our experience revealed that negative aspiration biopsies should be considered false negative until they could be confirmed by further investigations. (orig.) [de

  10. The effect of self-selected soothing music on fistula puncture-related pain in hemodialysis patients.

    Science.gov (United States)

    Shabandokht-Zarmi, Hosniyeh; Bagheri-Nesami, Masoumeh; Shorofi, Seyed Afshin; Mousavinasab, Seyed Nouraddin

    2017-11-01

    This study was intended to examine the effect of selective soothing music on fistula puncture-related pain in hemodialysis patients. This is a randomized clinical trial in which 114 participants were selected from two hemodialysis units by means of a non-random, convenience sampling method. The participants were then allocated in three groups of music (N = 38), headphone (N = 38), and control (N = 38). The fistula puncture-related pain was measured 1 min after venipuncture procedure in all three groups. The music group listened to their self-selected and preferred music 6 min before needle insertion into a fistula until the end of procedure. The headphone group wore a headphone alone without listening to music 6 min before needle insertion into a fistula until the end of procedure. The control group did not receive any intervention from the research team during needle insertion into a fistula. The pain intensity was measured immediately after the intervention in all three groups. This study showed a significant difference between the music and control groups, and the music and headphone groups in terms of the mean pain score after the intervention. However, the analysis did not indicate any significant difference between the headphone and control groups with regard to the mean pain score after the intervention. It is concluded that music can be used effectively for pain related to needle insertion into a fistula in hemodialysis patients. Future research should investigate the comparative effects of pharmacological and non-pharmacological interventions on fistula puncture-related pain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Comparison of dural puncture epidural technique versus conventional epidural technique for labor analgesia in primigravida

    Directory of Open Access Journals (Sweden)

    Pritam Yadav

    2018-01-01

    Full Text Available >Background: Dural puncture epidural (DPE is a method in which a dural hole is created prior to epidural injection. This study was planned to evaluate whether dural puncture improves onset and duration of labor analgesia when compared to conventional epidural technique.Methods and Materials: Sixty term primigravida parturients of ASA grade I and II were randomly assigned to two groups of 30 each (Group E for conventional epidural and Group DE for dural puncture epidural. In group E, epidural space was identified and 18-gauge multi-orifice catheter was threaded 5 cm into the epidural space. In group DE, dura was punctured using the combines spinal epidural (CSE spinal needle and epidural catheter threaded as in group E followed by 10 ml of injection of Ropivacaine (0.2% with 20 mcg of Fentanyl (2 mcg/ml in fractions of 2.5 ml. Later, Ropivacaine 10 ml was given as a top-up on patient request. Onset, visual analouge scale (VAS, sensory and motor block, haemodynamic variables, duration of analgesia of initial dose were noted along with mode of delivery and the neonatal outcome.Results: Six parturients in group DE achieved adequate analgesia in 5 minutes while none of those in group E (P 0.05.Conclusions: Both techniques of labor analgesia are efficacious; dural puncture epidural has the potential to fasten onset and improve quality of labor analgesia when compared with conventional epidural technique.

  12. Image-guided percutaneous disc sampling: impact of antecedent antibiotics on yield

    International Nuclear Information System (INIS)

    Agarwal, V.; Wo, S.; Lagemann, G.M.; Tsay, J.; Delfyett, W.T.

    2016-01-01

    Aim: To evaluate the effect of antecedent antimicrobial therapy on diagnostic yield from percutaneous image-guided disc-space sampling. Materials and methods: A retrospective review of the electronic health records of all patients who underwent image-guided percutaneous sampling procedures for suspected discitis/osteomyelitis over a 5-year period was performed. One hundred and twenty-four patients were identified. Demographics, medical history, and culture results were recorded as well as duration of presenting symptoms and whether antecedent antibiotic therapy had been administered. Results: Of the 124 patients identified who underwent image-guided percutaneous disc-space sampling, 73 had received antecedent antibiotic treatment compared with 51 who had not. The overall positive culture rate for the present study population was 24% (n=30). The positive culture rate from patients previously on antibiotics was 21% (n=15) compared with 29% (n=15) for patients who had not received prior antibiotic treatment, which is not statistically significant (p=0.26). Eighty-six percent (n=63) of patients who had antecedent antibiotics received treatment for 4 or more days prior to their procedure, whereas 14% (n=10) received treatment for 1–3 days prior to their procedure. The difference in culture positivity rate between these two groups was not statistically significant (p=0.43). Culture results necessitated a change in antibiotic therapy in a third of the patients who had received antecedent antibiotic therapy. Conclusion: Antecedent antibiotic therapy, regardless of duration, did not result in significantly diminished diagnostic yield from percutaneous sampling for suspected discitis/osteomyelitis. The present results suggest that percutaneous biopsy may nonetheless yield positive diagnostic information despite prior antimicrobial therapy. If the diagnostic information may impact choice of therapeutic regimen, percutaneous biopsy should still be considered in cases where

  13. MR guided percutaneous laser lumbar disk hernia ablation

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko [Jikei Univ., Chiba (Japan). Kashiwa Hospital; Abe, Toshiaki

    1998-03-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  14. MR guided percutaneous laser lumbar disk hernia ablation

    International Nuclear Information System (INIS)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko; Abe, Toshiaki.

    1998-01-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  15. Classifier-Guided Sampling for Complex Energy System Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Backlund, Peter B. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Eddy, John P. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    This report documents the results of a Laboratory Directed Research and Development (LDRD) effort enti tled "Classifier - Guided Sampling for Complex Energy System Optimization" that was conducted during FY 2014 and FY 2015. The goal of this proj ect was to develop, implement, and test major improvements to the classifier - guided sampling (CGS) algorithm. CGS is type of evolutionary algorithm for perform ing search and optimization over a set of discrete design variables in the face of one or more objective functions. E xisting evolutionary algorithms, such as genetic algorithms , may require a large number of o bjecti ve function evaluations to identify optimal or near - optimal solutions . Reducing the number of evaluations can result in significant time savings, especially if the objective function is computationally expensive. CGS reduce s the evaluation count by us ing a Bayesian network classifier to filter out non - promising candidate designs , prior to evaluation, based on their posterior probabilit ies . In this project, b oth the single - objective and multi - objective version s of the CGS are developed and tested on a set of benchm ark problems. As a domain - specific case study, CGS is used to design a microgrid for use in islanded mode during an extended bulk power grid outage.

  16. Access to the Superficial Femoral Artery in the Presence of a 'Hostile Groin': A Prospective Study

    International Nuclear Information System (INIS)

    Marcus, Adrian J.; Lotzof, Kevin; Howard, Adam

    2007-01-01

    Purpose. Lower limb angioplasty is commonly performed via antegrade common femoral artery (CFA) puncture, followed by selective superficial femoral artery (SFA) catheterization. Arterial access can be complicated by a 'hostile groin' (scarring, obesity, or previous failed CFA puncture). We prospectively investigated color duplex ultrasound (CDU)-guided SFA access for radiological interventions. Methods. Antegrade CDU-guided CFA and SFA puncture were compared in 30 patients requiring intervention for severe leg ischemia who had hostile groins. Demographics, screen time, radiation dose, intervention, and complications were prospectively recorded. Results. Treatment in 30 patients involved 44 angioplasties (40 transluminal, 4 subintimal) and 2 diagnostic angiograms. Fifteen of these patients had CDU-guided CFA punctures; in 8 of these patients CDU-guided CFA puncture 'failed' (i.e., there was failure to pass a guidewire or catheter into the CFA or SFA), necessitating immediate direct CDU-guided SFA puncture. Overall, the mean screen time and radiation dosage, via direct CDU-guided SFA puncture in 30 patients, was 4.8 min and 464 Gy cm 2 respectively. With CDU-guided CFA puncture, mean screen time (10 min), radiation dose (2023 Gy cm 2 ), and complications (13%) were greater when compared with the SFA puncture results overall and in the same patients at subsequent similar procedures (2.7 min, 379 Gy cm 2 (p < 0.05), no complications in this subgroup). Five complications occurred: 2 each at CFA and SFA entry sites, and 1 angioplasty embolus. Conclusions. The CDU-guided SFA puncture technique was both more effective than CDU-guided CFA access in patients with scarred groins, obesity, or failed CFA punctures and safer, with reduced screen times, radiation doses, and complications

  17. Fluoroscopically-Guided Posterior Approach for Shoulder Magnetic Resonance Arthrography: Comparison with Conventional Anterior Approach

    International Nuclear Information System (INIS)

    Yoo, Koun J.; Ha, Doo Hoe; Lee, Sang Min

    2011-01-01

    To prospectively evaluate the usefulness of the fluoroscopically-guided posterior approach compared with the anterior approach for shoulder magnetic resonance(MR) arthrography. Institutional review board approval and informed consent were obtained. Among 60 shoulder MR arthrographies performed on 59 patients with symptomatic shoulders, an intra-articular injection was performed (30 cases using the anterior approach and 30 using the posterior approach). Procedure-related pain was assessed by using a 5 score visual analogue scale (VAS). Depth of the puncture and standardized depth of puncture by body mass index (BMI) were recorded. The contrast leakage along the course of the puncture was evaluated by reviewing the MR. The statistical analyses included the Mann-Whitney U and Kruskal-Wallis test. There was no significant difference in VAS scores between the anterior and posterior groups (1.77 ± 1.10 vs. 1.80 ± 0.96). Depth of puncture and standardized depth of puncture by BMI were significantly shorter in the posterior group than those in the anterior group (4.4 ± 0.8 cm and 1.8 ± 0.3 cm vs. 6.6 ± 0.9 cm and 2.8 ± 0.4 cm, p < 0.001), respectively. The incidence of contrast leakage was more frequent in the posterior group (p = 0.003). The posterior approach will be useful in shoulder MR arthrography with a suspected anterior pathology, a postoperative follow-up study or obese patient.

  18. 40 CFR Table 3 to Subpart Xxxx of... - Emission Limits for Puncture Sealant Application Affected Sources

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Emission Limits for Puncture Sealant Application Affected Sources 3 Table 3 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 3 Table 3 to Subpart XXXX of Part 63—Emission Limits for Puncture...

  19. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits for Puncture Sealant Application Control Devices 4 Table 4 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 4 Table 4 to Subpart XXXX of Part 63—Operating Limits for Puncture...

  20. A new cerebral vasospasm model established with endovascular puncture technique

    International Nuclear Information System (INIS)

    Tu Jianfei; Liu Yizhi; Ji Jiansong; Zhao Zhongwei

    2011-01-01

    Objective: To investigate the method of establishing cerebral vasospasm (CVS) models in rabbits by using endovascular puncture technique. Methods: Endovascular puncture procedure was performed in 78 New Zealand white rabbits to produce subarachnoid hemorrhage (SAH). The survival rabbits were randomly divided into seven groups (3 h, 12 h, 1 d, 2 d, 3 d, 7 d and 14 d), with five rabbits in each group for both study group (SAH group) and control group. Cerebral CT scanning was carried out in all rabbits both before and after the operation. The inner diameter and the thickness of vascular wall of both posterior communicating artery (PcoA) and basilar artery (BA) were determined after the animals were sacrificed, and the results were analyzed. Results: Of 78 experimental rabbits, CVS model was successfully established in 45, including 35 of SAH group and 10 control subgroup. The technical success rate was 57.7%. Twelve hours after the procedure, the inner diameter of PcoA and BA in SAH group was decreased by 45.6% and 52.3%, respectively, when compared with these in control group. The vascular narrowing showed biphasic changes, the inner diameter markedly decreased again at the 7th day when the decrease reached its peak to 31.2% and 48.6%, respectively. Conclusion: Endovascular puncture technique is an effective method to establish CVS models in rabbits. The death rate of experimental animals can be decreased if new interventional material is used and the manipulation is carefully performed. (authors)

  1. Prospective evaluation of the radiologist's hand dose in CT-guided interventions

    International Nuclear Information System (INIS)

    Rogits, B.; Jungnickel, K.; Loewenthal, D.; Dudeck, O.; Pech, M.; Ricke, J.; Kropf, S.; Nekolla, E.A.; Wieners, G.

    2013-01-01

    Purpose: Assessment of radiologist's hand dose in CT-guided interventions and determination of influencing factors. Materials and Methods: The following CT-guided interventions were included: Core biopsy, drainage, periradicular therapy, and celiac plexus neurolysis. The hand dose was measured with an immediately readable dosimeter, the EDD-30 (Unfors, Sweden). The default parameters for CT fluoroscopy were 120 kV, 90 mA and a 4 mm slice thickness. All interventions were performed on a 16-slice CT unit (Aquilion 16 Toshiba, Japan). The tumor size, degree of difficulty (1 - 3), level of experience and device parameters (mAs, dose-length product, scan time) were documented. Results: 138 CT-guided interventions (biopsy n = 99, drainage n = 23, pain therapy n = 16) at different locations (lung n = 41, retroperitoneum n = 53, liver n = 25, spine n = 19) were included. The lesion size was 4 - 240 mm (median: 23 mm). The fluoroscopy time per intervention was 4.6 - 140.2 s (median: 24.2 s). The measured hand dose ranged from 0.001 - 3.02 mSv (median: 0.22 mSv). The median hand dose for lung puncture (n = 41) was slightly higher (median: 0.32 mSv, p = 0.01) compared to that for the liver, retroperitoneum and other. Besides physical influencing factors, the degree of difficulty (p = 0.001) and summed puncture depth (p = 0.004) correlated significantly with the hand dose. Conclusion: The median hand dose for different CT-guided interventions was 0.22 mSv. Therefore, the annual hand dose limit would normally only be reached with about 2000 interventions. (orig.)

  2. Fluoroscopically guided percutaneous jejunostomy: outcomes in 25 consecutive patients

    International Nuclear Information System (INIS)

    Yang, Z.Q.; Shin, J.H.; Song, H.-Y.; Kwon, J.H.; Kim, J.-W.; Kim, K.R.; Kim, J.-H.

    2007-01-01

    Aim: To assess the feasibility and safety of fluoroscopically guided percutaneous jejunostomy. Material and methods: Between May 1999 and August 2006 percutaneous jejunostomy was attempted in 25 patients. A 5 F vascular catheter (n = 20) or a 7.5 F multifunctional coil catheter (n = 5) was used to insufflate the jejunum. The distended jejunum was punctured using a 17 G needle (n = 19) or a 21 G Chiba needle (n = 6) with the inserted catheter as a target. A 12 or 14 F loop feeding tube was inserted after serial dilations. The technical success, complications, 30-day mortality, and in-dwelling period of the feeding tube placement were evaluated. Results: The technical success rate was 92% (23/25). Technical failures (n = 2) resulted from the inability to insufflate the jejunum secondary to failure to pass the catheter through a malignant stricture at the oesophagojejunostomy site and thus subsequent puncture of the undistended jejunum failed, or failure to introduce the Neff catheter into the jejunum. Pericatheter leakage with pneumoperitoneum was a complication in three patients (12%) and was treated conservatively. The 30-day mortality was 13% (3/23); however, there was no evidence that these deaths were attributed to the procedure. Except for four patients who were lost to follow-up and two failed cases, 15 of the 19 jejunostomy catheters were removed because of patient death (n = 12) or completion of treatment (n = 3), with a mean and median in-dwelling period of 231 and 87 days, respectively. Conclusions: Fluoroscopically guided percutaneous jejunostomy is a feasible procedure with a high technical success and a low complication rate. In addition to a 17 G needle, a 21 G needle can safely be used to puncture the jejunum

  3. Ultrasound guided double injection of blood into cisterna magna: a rabbit model for treatment of cerebral vasospasm.

    Science.gov (United States)

    Chen, Yongchao; Zhu, Youzhi; Zhang, Yu; Zhang, Zixuan; Lian, Juan; Luo, Fucheng; Deng, Xuefei; Wong, Kelvin K L

    2016-02-06

    Double injection of blood into cisterna magna using a rabbit model results in cerebral vasospasm. An unacceptably high mortality rate tends to limit the application of model. Ultrasound guided puncture can provide real-time imaging guidance for operation. The aim of this paper is to establish a safe and effective rabbit model of cerebral vasospasm after subarachnoid hemorrhage with the assistance of ultrasound medical imaging. A total of 160 New Zealand white rabbits were randomly divided into four groups of 40 each: (1) manual control group, (2) manual model group, (3) ultrasound guided control group, and (4) ultrasound guided model group. The subarachnoid hemorrhage was intentionally caused by double injection of blood into their cisterna magna. Then, basilar artery diameters were measured using magnetic resonance angiography before modeling and 5 days after modeling. The depth of needle entering into cisterna magna was determined during the process of ultrasound guided puncture. The mortality rates in manual control group and model group were 15 and 23 %, respectively. No rabbits were sacrificed in those two ultrasound guided groups. We found that the mortality rate in ultrasound guided groups decreased significantly compared to manual groups. Compared with diameters before modeling, the basilar artery diameters after modeling were significantly lower in manual and ultrasound guided model groups. The vasospasm aggravated and the proportion of severe vasospasms was greater in ultrasound guided model group than that of manual group. In manual model group, no vasospasm was found in 8 % of rabbits. The ultrasound guided double injection of blood into cisterna magna is a safe and effective rabbit model for treatment of cerebral vasospasm.

  4. An evaluation of the Johnson-Cook model to simulate puncture of 7075 aluminum plates.

    Energy Technology Data Exchange (ETDEWEB)

    Corona, Edmundo; Orient, George Edgar

    2014-02-01

    The objective of this project was to evaluate the use of the Johnson-Cook strength and failure models in an adiabatic finite element model to simulate the puncture of 7075- T651 aluminum plates that were studied as part of an ASC L2 milestone by Corona et al (2012). The Johnson-Cook model parameters were determined from material test data. The results show a marked improvement, in particular in the calculated threshold velocity between no puncture and puncture, over those obtained in 2012. The threshold velocity calculated using a baseline model is just 4% higher than the mean value determined from experiment, in contrast to 60% in the 2012 predictions. Sensitivity studies showed that the threshold velocity predictions were improved by calibrating the relations between the equivalent plastic strain at failure and stress triaxiality, strain rate and temperature, as well as by the inclusion of adiabatic heating.

  5. Postpartum cortical venous thrombosis: An unusual presentation of postdural puncture headache

    Directory of Open Access Journals (Sweden)

    Opal Raj

    2016-01-01

    Full Text Available Headache is a common occurrence during pregnancy. A postural headache is invariably considered to be a postdural puncture headache in patients who receive neuraxial anesthesia with or without obvious or incidental dural puncture. Cerebral venous thrombosis (CVT is rare in pregnancy and in the postpartum period, with an incidence of 1:10,000–1:25,000. Pregnancy-induced changes in coagulation result in a hypercoagulable state, which may naturally reduce the incidence of postpartum hemorrhage, but may also increase the risk of CVT. Postpartum headache being frequently encountered may complicate the diagnosis of CVT. We report a case of a woman who developed a postpartum CVT after an accidental wet tap and intrathecal catheter placement during labor.

  6. On Railroad Tank Car Puncture Performance: Part I - Considering Metrics

    Science.gov (United States)

    2016-04-12

    This paper is the first in a two-part series on the puncture performance of railroad tank cars carrying hazardous materials in the event of an accident. Various metrics are often mentioned in the open literature to characterize the structural perform...

  7. On Railroad Tank Car Puncture Performance: Part II - Estimating Metrics

    Science.gov (United States)

    2016-04-12

    This paper is the second in a two-part series on the puncture performance of railroad tank cars carrying hazardous materials in the event of an accident. Various metrics are often mentioned in the open literature to characterize the structural perfor...

  8. A case of subdural hematoma following lumbar puncture

    Directory of Open Access Journals (Sweden)

    Ramatharaknath Vemuri

    2017-01-01

    Full Text Available Lumbar puncture (LP is a frequent procedure done for administration of spinal anesthesia or for obtaining cerebrospinal fluid for analysis. The common complications of LP are pain at the local site and headache. Fortunately, the serious complications such as infections of central nervous system, brain stem herniation, and subdural hematoma are rare. We present a rare case of subdural hematoma following a LP.

  9. Use of a Puncture Needle for Recanalization of an Occluded Right Subclavian Vein

    International Nuclear Information System (INIS)

    Gupta, Himanshu; Murphy, Timothy P.; Soares, Gregory M.

    1998-01-01

    We report a patient in whom we used a puncture needle to initiate percutaneous recanalization of a chronic occlusion of the junction between the right subclavian vein and the right brachiocephalic vein. Under fluoroscopic guidance, an 18-gauge needle was used to puncture the right subclavian vein. When contrast material injected through the needle confirmed intravascular location, the needle was advanced until it deflected and perforated an occlusion balloon target positioned within the right brachiocephalic vein. This technique may be useful in patients with central venous occlusions that are refractory to traversal using traditional catheter and guidewire techniques

  10. A case of transitional cell carcinoma associated with pericalyceal diverticulum diagnosed by CT guided percutaneous cystgraphy

    International Nuclear Information System (INIS)

    Sasaki, Fumio; Koga, Sukehiko; Takeuchi, Akira; Anno, Hirofumi; Hujita, Tamio

    1983-01-01

    Computed tomography (CT) performed on a 42-year-old male patient with a chief complaint of hematuria revealed a renal cyst with a thickened and irregularly shaped wall. CT with contrast medium injected into the cyst by puncture under CT guide detected tumors on the cystic wall preoperatively. (Ueda, J.)

  11. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, Jean-Marc; Deprez, Pierre H; Jenssen, Christian

    2017-01-01

    For pancreatic solid lesions, ESGE recommends performing endoscopic ultrasound (EUS)-guided sampling as first-line procedure when a pathological diagnosis is required. Alternatively, percutaneous sampling may be considered in metastatic disease.Strong recommendation, moderate quality evidence.In ...

  12. Consensus guidelines for lumbar puncture in patients with neurological diseases

    NARCIS (Netherlands)

    S. Engelborghs (Sebastiaan); Niemantsverdriet, E. (Ellis); H. Struyfs (Hanne); K. Blennow (Kaj); Brouns, R. (Raf); M. Comabella (Manuel); I. Dujmovic (Irena); W.M. van der Flier (Wiesje); L. Frölich (Lutz); D. Galimberti (Daniela); S. Gnanapavan (Sharmilee); B. Hemmer` (Bernhard); E.I. Hoff (Erik I.); Hort, J. (Jakub); E. Iacobaeus (Ellen); M. Ingelsson (Martin); Jan de Jong, F. (Frank); Jonsson, M. (Michael); M. Khalil (Michael); J. Kuhle (Jens); A. Lleo (Alberto); A. De Mendonça (Alexandre); J.L. Molinuevo (José Luis); G. Nagels (Guy); C. Paquet (Claire); L. Parnetti; C.M.A.A. Roks (Gerwin); Rosa-Neto, P. (Pedro); P. Scheltens (Philip); C. Skarsgård (Constance); E. Stomrud (Erik); H. Tumani (Hayrettin); P. Visser (Pim); Wallin, A. (Anders); B. Winblad; H. Zetterberg (Henrik); F.H. Duits (Flora H.); C.E. Teunissen (Charlotte)

    2017-01-01

    textabstractIntroduction Cerebrospinal fluid collection by lumbar puncture (LP) is performed in the diagnostic workup of several neurological brain diseases. Reluctance to perform the procedure is among others due to a lack of standards and guidelines to minimize the risk of complications, such as

  13. Complications of lumbar puncture in a child treated for leukaemia

    International Nuclear Information System (INIS)

    Staebler, Melanie; Delpierre, Isabelle; Damry, Nash; Christophe, Catherine; Azzi, Nadira; Sekhara, Tayeb

    2005-01-01

    Lumbar puncture may lead to neurological complications. These include intracranial hypotension, cervical epidural haematomas, and cranial and lumbar subdural haematomas. MRI is the modality of choice to diagnose these complications. This report documents MRI findings of such complications in a child treated for leukaemia. (orig.)

  14. Transfundal puncture of a large ovarian cyst with hysteroscopic and ultrasonographic guidance.

    Science.gov (United States)

    Zolnierczyk, Piotr; Cendrowski, Krzysztof; Sawicki, Wlodzimierz

    2015-01-01

    This paper describes the case of an 83-year-old patient with hypertension, diabetes, obesity (body mass index - 38), congestive heart failure, and history of cardiac surgery, who was referred for a diagnostic-therapeutic decompression of a large, symptomatic ovarian cyst. Due to anatomical conditions, the only safe way was a transfundal puncture under mini-hysteroscopic and ultrasound guidance. A puncture with aspiration of 300 mL of serous fluid from the cyst was performed without technical problems and complications. Cytology showed no cancer cells in the examined liquid. Relief from pain and compression discomfort was achieved in the patient. This case shows the possibility of combining ultrasound and minimally invasive diagnostic methods like hysteroscopy in selected clinical situations.

  15. CT-guided percutaneous radiofrequency ablation of hepatic malignancies located in unusual regions under general anesthesia

    International Nuclear Information System (INIS)

    Pan Jie; Chen Shaohui; Lu Xin; Mao Yilei; Sang Xinting; Chen Fang; Li Yumei; Huang Yuguang; Jin Zhengyu

    2010-01-01

    Objective: To discuss the feasibility of CT-guided percutaneous radiofrequency ablation (RFA) of liver malignancies located in unusual regions under general anesthesia, and to assess its clinical value. Methods: Eighteen patients with a total of 26 malignant hepatic lesions were enrolled in this study. The lesions were located at diaphragmatic surface, hepatic hilum, hepatic subcapsular site,side of inferior vena cava, side of gallbladder or near by colon. Transcatheter arterial chemoembolization was performed in all patients, which was followed by CT-guided percutaneous RFA under general anesthesia. The time used for puncturing and the time used for putting the needles to the scheduled sites were recorded. A follow-up for 115 months was conducted. The complications and the therapeutic results were observed. Results: For all patients,the procedure of puncture and needle placement was completed in 1-3 minutes. A total of 35 RFA procedures were conducted for 26 lesions. No severe complications occurred. Complete necrosis was observed in 20 tumors and partial necrosis in 6 tumors. Conclusion: The result of this study indicates that CT-guided percutaneous RFA under general anesthesia is a feasible technique for the treatment of liver malignancies located at unusual regions. This technique is very helpful for reducing the manipulating difficulty and lowing the complication risk of RFA procedures. (authors)

  16. Comparison of two navigation systems for CT-guided interventions under special consideration of the ergonomic properties of the used systems

    International Nuclear Information System (INIS)

    Schulz, T.; Roettger, S.; Bahner-Heyne, E.J.; Kluge, G.

    2009-01-01

    Purpose: investigation of the influence of CT-based navigation systems on the success of an intervention, assessment of the advantages and disadvantages of the utilized systems, and evaluation of the ergonomic system properties. Materials and method: a simple guiding system PatPos Invent trademark and the computer-based navigation system PinPoint trademark were employed on two CT systems. In order to investigate the influence of the navigation aids on the success of the interventions, 96 prospective, randomized, and standardized punctures were performed on a specifically developed, rigid phantom. 16 examiners punctured 6 targets with 3 degrees of difficulty with the navigation aids. Results: irrespective of the experience of the examiner, both navigation systems guided the target with an equal degree of certainty. PinPoint significantly reduced the length of the examination time (12 - 25 min) as compared to PatPos Invent (20 - 40 min). The expectation conformity and comprehensibility of PatPos Invent were assessed significantly more positively than PinPoint with regard to the general handling of the system. In contrast, the assessment of the usability during preoperative setup favored PinPoint. The type of navigation system has no influence on the precision of the implementation of a puncture procedure. (orig.)

  17. Diagnostic Accuracy of MRI-guided Percutaneous Transthoracic Needle Biopsy of Solitary Pulmonary Nodules

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Shangang, E-mail: 1198685580@qq.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China); Li, Chengli, E-mail: chenglilichina@yeah.net [Shandong University, Department of Interventional MRI, Shandong Medical Imaging Research Institute (China); Yu, Xuejuan, E-mail: yuxuejuan2011@126.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China); Liu, Ming, E-mail: mingliuyxs@163.com [Shandong University, Department of Interventional MRI, Shandong Medical Imaging Research Institute (China); Fan, Tingyong, E-mail: FTY681105@sohu.com; Chen, Dong, E-mail: 857984870@qq.com; Zhang, Pinliang, E-mail: zhangpinliang@163.com; Ren, Ruimei, E-mail: liusg708@qq.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China)

    2015-04-15

    ObjectiveThe purpose of our study was to evaluate the diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy (PTNB) of solitary pulmonary nodules (SPNs).MethodsRetrospective review of 69 patients who underwent MR-guided PTNB of SPNs was performed. Each case was reviewed for complications. The final diagnosis was established by surgical pathology of the nodule or clinical and imaging follow-up. Pneumothorax rate and diagnostic accuracy were compared between two groups according to nodule diameter (≤2 vs. >2 cm) using χ{sup 2} chest and Fisher’s exact test, respectively.ResultsThe success rate of single puncture was 95.6 %. Twelve (17.4 %) patients had pneumothorax, with 1 (1.4 %) requiring chest tube insertion. Mild hemoptysis occurred in 7 (7.2 %) patients. All of the sample material was sufficient for histological diagnostic evaluation. Pathological analysis of biopsy specimens showed 46 malignant, 22 benign, and 1 nondiagnostic nodule. The final diagnoses were 49 malignant nodules and 20 benign nodules basing on postoperative histopathology and clinical follow-up data. One nondiagnostic sample was excluded from calculating diagnostic performance. A sensitivity, specificity, accuracy, positive predictive value, and negative predictive value in diagnosing SPNs were 95.8, 100, 97.0, 100, and 90.9 %, respectively. Pneumothorax rate, diagnostic sensitivity, and accuracy were not significantly different between the two groups (P > 0.05).ConclusionsMRI-guided PTNB is safe, feasible, and high accurate diagnostic technique for pathologic diagnosis of pulmonary nodules.

  18. A user`s guide to LHS: Sandia`s Latin Hypercube Sampling Software

    Energy Technology Data Exchange (ETDEWEB)

    Wyss, G.D.; Jorgensen, K.H. [Sandia National Labs., Albuquerque, NM (United States). Risk Assessment and Systems Modeling Dept.

    1998-02-01

    This document is a reference guide for LHS, Sandia`s Latin Hypercube Sampling Software. This software has been developed to generate either Latin hypercube or random multivariate samples. The Latin hypercube technique employs a constrained sampling scheme, whereas random sampling corresponds to a simple Monte Carlo technique. The present program replaces the previous Latin hypercube sampling program developed at Sandia National Laboratories (SAND83-2365). This manual covers the theory behind stratified sampling as well as use of the LHS code both with the Windows graphical user interface and in the stand-alone mode.

  19. Effectiveness of combined laser-puncture and conventional wound care to accelerate diabetic foot ulcer healing

    Directory of Open Access Journals (Sweden)

    Adiningsih Srilestari

    2017-05-01

    Full Text Available Background: Impaired wound healing is a common complication of diabetes. It has complex pathophysiologic mechanisms and often necessitates amputation. Our study aimed to evaluate the effectiveness of combined laser-puncture and conventional wound care in the treatment of diabetic foot ulcers.Methods: This was a double-blind controlled randomized clinical trial on 36 patients, conducted at the Metabolic Endocrine Outpatient Clinic, Cipto Mangunkusumo Hospital, Jakarta, between May and August 2015. Stimulation by laser-puncture (the treatment group or sham stimulation (the control group were performed on top of the standard wound care. Laser-puncture or sham were done on several acupuncture points i.e. LI4 Hegu, ST36 Zusanli, SP6 Sanyinjiao and KI3 Taixi bilaterally, combined with irradiation on the ulcers itself twice a week for four weeks. The mean reduction in ulcer sizes (week 2–1, week 3–1, week 4–1 were measured every week and compared between the two groups and analyzed by Mann-Whitney test.Results: The initial median ulcer size were 4.75 (0.10–9.94 cm2 and 2.33 (0.90–9.88 cm2 in laser-puncture and sham groups, respectively (p=0.027. The median reduction of ulcer size at week 2–1 was -1.079 (-3.25 to -0.09 vs -0.36 (-0.81 to -1.47 cm2, (p=0.000; at week 3–1 was -1.70 (-3.15 to -0.01 vs -0.36 (-0.80 to -0.28 cm2, (p=0.000; and at week 4–1 was -1.22 (-2.72 to 0.00 vs -0.38 (-0.74 to -0.57 cm2, (p=0.012.Conclusion: Combined laser-puncture and conventional wound care treatment are effective in accelerating the healing of diabetic foot ulcer.

  20. Effect of needle puncture and electro-acupuncture on mucociliary clearance in anesthetized quails

    Directory of Open Access Journals (Sweden)

    Wang Tianshan

    2006-02-01

    Full Text Available Abstract Background Acupuncture therapy for obstructive respiratory diseases has been effectively used in clinical practice and the acupuncture points or acupoints of Zhongfu and Tiantu are commonly-used acupoints to treat patients with the diseases. Since the impaired mucociliary clearance is among the most important features of airway inflammation in most obstructive respiratory diseases, the effect of needle puncture and electro-acupuncture at the specific acupoints on tracheal mucociliary clearance was investigated in anesthetized quails. Methods Mucociliary transport velocity on tracheal mucosa was measured through observing the optimal pathway, and fucose and protein contents in tracheal lavages were determined with biochemical methods. In the therapeutic group, needle puncture or electro-acupuncture stimulation to the acupoints was applied without or with constant current output in 2 mA and at frequency of 100 Hz for 60 minutes. In the sham group, electro-acupuncture stimulation to Liangmen was applied. Results Our present experiments demonstrated that the electro-acupuncture stimulation to Zhongfu and Tiantu significantly increased tracheal mucociliary transport velocity and decreased the content of protein in the tracheal lavage, compared with the control group. Moreover, either needle puncture or electro-acupuncture stimulation to Zhongfu and Tiantu significantly reverted the human neutrophil elastase-induced decrease in tracheal mucociliary transport velocity and human neutrophil elastase -induced increase in the contents of fucose and protein in the tracheal lavage, compared with the control group. Conclusion These results suggest that either needle puncture or electro-acupuncture stimulation to the effective acupoints significantly improves both airway mucociliary clearance and the airway surface liquid and that the improvements maybe ascribed to both the special function of the points and the substantial stimulation of electricity.

  1. Puncture resistance of Type B transport systems

    International Nuclear Information System (INIS)

    Rack, H.J.; Cheresh, M.C.

    1980-01-01

    This report describes a recent attempt to develop a test method for use in screening materials and for evaluating the effects of certain parameters, for example section stiffness, on container penetration resistance. In addition, it illustrates the application of this procedure to the selection of a sheet steel for a transuranic waste (TRUPACT) container. The test consists of penetrating a specimen, normally 0.6 m square, with a punch (tup) attached to a falling weight and recording and analyzing the force-time history to determine the energy absorption during the impact event. The test as developed simulates certain aspects of the 10CFR71 drop test in order to provide a means of comparing, for example, the penetrating resistance of various steels, this resistance being defined as the energy required to initiate fracture in the specimen. In summary, this examination suggests that it should be possible to develop a laboratory test to rank and select materials for maximum puncture resistance. Although the initial results appear promising, more effort will be required before this procedure can be routinely applied to examining the various factors which control the puncture resistance of these materials. These results do, nonetheless, show that high-strength, low-alloy steels do offer significant advantages over mild steel for container penetration protection. Indeed, one of these steels, NAX-80, is presently considered as a prime candidate for the TRUPACT container being developed at Sandia National Laboratories

  2. Haemostasis and Safety Measures before Lumbar Puncture in the Haematology Ward

    DEFF Research Database (Denmark)

    Møller, Anders; Bjerrum, Ole Weis; Afshari, Arash

    2015-01-01

    BACKGROUND/AIMS: Thrombocytopenia and the increasing use and variety of antithrombotic drugs is a challenge prior to lumbar puncture. This study examined the Danish haematology practice regarding drug pausation, assessment of haemostasis and whether fundoscopy is a routine safety measure. METHODS...

  3. Utility of the puncture of the radial artery in interventionist radiology

    International Nuclear Information System (INIS)

    Triana Rodriguez, Carlos Eduardo; Montes S, Mauricio; Barragan F, Jaime; Ucros Diaz Pablo; Ucros Diaz, Ignacio; Castillo, Luis Fernando

    1998-01-01

    We present the radial artery access, previous evaluation of collateral circulation with Allen's Test, as an alternative vascular access in patients with contraindications for femoral or axillary approaches. The radial artery puncture offers advantages, such as diminished bleeding and hematoma formation

  4. A navigation system for percutaneous needle interventions based on PET/CT images: design, workflow and error analysis of soft tissue and bone punctures.

    Science.gov (United States)

    Oliveira-Santos, Thiago; Klaeser, Bernd; Weitzel, Thilo; Krause, Thomas; Nolte, Lutz-Peter; Peterhans, Matthias; Weber, Stefan

    2011-01-01

    Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well

  5. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    International Nuclear Information System (INIS)

    Niu, Xiang Ke; Bhetuwal, Anup; Yang, Han Feng

    2015-01-01

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  6. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Xiang Ke [Dept. of Radiology, Affiliated Hospital of Chengdu University, Chengdu (China); Bhetuwal, Anup; Yang, Han Feng [Dept. of Radiology, Sichuan Key Laboratory of Medical Imaging, Affiliated Hospital of North Sichuan Medical College, Nanchong (China)

    2015-02-15

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  7. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    Science.gov (United States)

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (Ppleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  8. Application of a New Guiding System in Percutaneous Biopsies

    International Nuclear Information System (INIS)

    Petsas, Theodore; Tsota, Irene; Kalogeropoulou, Christina P.; Liatsikos, Evangelos N.

    2007-01-01

    We herein describe the application of a new guiding system designed for percutaneous biopsies. The guiding system set is composed of a 0.41 mm (27G) stainless steel guide stylet and a 22G Chiba needle. Following the initial insertion of the Chiba needle, the stylet is advanced via the needle toward the lesion. The stylet serves either as a guide for the Chiba needle or as an exchange wire for the introduction of larger or cutting biopsy needles. The stylet can also be curved prior to its insertion to facilitate access to lesions which require needle redirection. The technique was applied to 117 cases (54 thoracic, 31 abdominal, 21 pelvic, and 11 vertebral lesions.) The main advantage of the stylet is its small diameter, rendering it atraumatic and permitting multiple punctures for the successful final targeting of the lesion. With this guiding set we achieved targeting of difficult lesions. Furthermore, larger needles were more easily introduced in locations that posed technical difficulties. No major complications were observed. The complication rate was comparable to that of the conventional biopsy technique. The technique using the guide stylet was easily performed and could be applied to almost all organs

  9. J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system

    International Nuclear Information System (INIS)

    Hama, Yukihiro; Kusano, Shoichi; Makita, Kohzoh

    2004-01-01

    The aim of this study was to verify the feasibility of using a J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system (RPCS). Twenty-five patients with various hepatic malignancies underwent percutaneous implantation of an RPCS through the left subclavian artery for regional chemotherapy. To successfully puncture the left subclavian artery, a J-tipped guidewire was used as a target with fluoroscopic guidance. Technical success and complication rates, and numbers of puncture failures, were retrospectively analyzed. Implantation of the RPCS was successful in all patients. Eight (32%) patients had minor complications and no patient had major complications. The number of puncture failures per patient was 0 to 1 (mean=0.32). The J-tipped guidewire is a safe and appropriate target for puncture of the subclavian artery in the placement of an RPCS. (orig.)

  10. User's and reference guide to the INEL RML/analytical radiochemistry sample tracking database version 1.00

    International Nuclear Information System (INIS)

    Femec, D.A.

    1995-09-01

    This report discusses the sample tracking database in use at the Idaho National Engineering Laboratory (INEL) by the Radiation Measurements Laboratory (RML) and Analytical Radiochemistry. The database was designed in-house to meet the specific needs of the RML and Analytical Radiochemistry. The report consists of two parts, a user's guide and a reference guide. The user's guide presents some of the fundamentals needed by anyone who will be using the database via its user interface. The reference guide describes the design of both the database and the user interface. Briefly mentioned in the reference guide are the code-generating tools, CREATE-SCHEMA and BUILD-SCREEN, written to automatically generate code for the database and its user interface. The appendices contain the input files used by the these tools to create code for the sample tracking database. The output files generated by these tools are also included in the appendices

  11. Liouville theory and uniformization of four-punctured sphere

    OpenAIRE

    Hadasz, Leszek; Jaskolski, Zbigniew

    2006-01-01

    Few years ago Zamolodchikov and Zamolodchikov proposed an expression for the 4-point classical Liouville action in terms of the 3-point actions and the classical conformal block. In this paper we develop a method of calculating the uniformizing map and the uniformizing group from the classical Liouville action on n-punctured sphere and discuss the consequences of Zamolodchikovs conjecture for an explicit construction of the uniformizing map and the uniformizing group for the sphere with four ...

  12. Simulated tempering distributed replica sampling: A practical guide to enhanced conformational sampling

    Energy Technology Data Exchange (ETDEWEB)

    Rauscher, Sarah; Pomes, Regis, E-mail: pomes@sickkids.ca

    2010-11-01

    Simulated tempering distributed replica sampling (STDR) is a generalized-ensemble method designed specifically for simulations of large molecular systems on shared and heterogeneous computing platforms [Rauscher, Neale and Pomes (2009) J. Chem. Theor. Comput. 5, 2640]. The STDR algorithm consists of an alternation of two steps: (1) a short molecular dynamics (MD) simulation; and (2) a stochastic temperature jump. Repeating these steps thousands of times results in a random walk in temperature, which allows the system to overcome energetic barriers, thereby enhancing conformational sampling. The aim of the present paper is to provide a practical guide to applying STDR to complex biomolecular systems. We discuss the details of our STDR implementation, which is a highly-parallel algorithm designed to maximize computational efficiency while simultaneously minimizing network communication and data storage requirements. Using a 35-residue disordered peptide in explicit water as a test system, we characterize the efficiency of the STDR algorithm with respect to both diffusion in temperature space and statistical convergence of structural properties. Importantly, we show that STDR provides a dramatic enhancement of conformational sampling compared to a canonical MD simulation.

  13. Intraarterial digital subtraction angiography after plastic surgery by thin-needle puncture

    International Nuclear Information System (INIS)

    Langer, M.; Fiegler, W.; Claussen, C.; Koehler, D.; Felix, R.; Hepp, W.

    1984-01-01

    Over the period of a year (1983), 44 intraarterial digital subtraction angiographies (DSA) via direct thin-needle puncture of a vascular bypass or following vascular graft were carried the rough. The only complication that occured: paravasal injection, was clinically insignificant and could be avoided by a change in the puncture-technique. It was possible to carry through the investigation in out-patients. In all cases, diagnostically useful picture material for a possible surgical intervention was obtained. The pictures always were high-grade, independently of the patient's circulation time. Because this is a simple investigation and because of the small risk of complications, it has come to be regularly carried through as a routine in the authors' clinic. According to investigations carried through on the collective of patients of a vascular surgery department, occlusions or anastomotic aneurismus account for most of the angiological disorders. (orig.) [de

  14. Effect of puncture through frontal lobe in the treatment of intracranial hematoma

    Directory of Open Access Journals (Sweden)

    DOU Bo-sheng

    2013-12-01

    Full Text Available This study aims to discuss the effect of an easy puncture through frontal lobe in the treatment of deep brain hematoma. The lesions of 37 patients with basal ganglia hemorrhage were accurately positioned by CT scan. Drainage tube was placed in the center of hematoma through frontal lobe and blood was aspirated. Urokinase 30 × 103 U was injected in the hematoma postoperatively to promote the evacuation of hematoma. Postoperative CT scan showed more than 75% hematoma was cleared in all patients after 3-7 d. Two patients died of complications; 2 patients were severely disabled; 3 rebleeding happened. Almost 33 patients had a good recovery. Minimal invasion, convenient operation and exact location were the adventages of this puncture and it does not need complicated device.

  15. Percutaneous CT-guided sacroiliac joint sampling for infection: aspiration, biopsy, and technique.

    Science.gov (United States)

    Knipp, David; Simeone, F Joseph; Nelson, Sandra B; Huang, Ambrose J; Chang, Connie Y

    2018-04-01

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning.

  16. Percutaneous CT-guided sacroiliac joint sampling for infection. Aspiration, biopsy, and technique

    Energy Technology Data Exchange (ETDEWEB)

    Knipp, David; Simeone, F.J.; Huang, Ambrose J.; Chang, Connie Y. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Nelson, Sandra B. [Massachusetts General Hospital, Infectious Disease Unit, Department of Medicine, Boston, MA (United States)

    2018-04-15

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning. (orig.)

  17. Dynamic telecytologic evaluation of imprint cytology samples from CT-guided lung biopsies: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut [Otto Wagner Hospital, Department of Radiology, Vienna (Austria); Medical University of Vienna, Department of Radiology, Vienna (Austria); Medical University of Vienna, Vienna General Hospital, Department of Radiology, Vienna (Austria); Hoffmann, Elisabeth; Schober, Ewald; Mostbeck, Gerhard [Otto Wagner Hospital, Department of Radiology, Vienna (Austria); Bernhardt, Klaus; Schalleschak, Johann [Otto Wagner Hospital, Department of Laboratory Medicine, Vienna (Austria); Rowhani, Marcel [Otto Wagner Hospital, Department of Respiratory and Critical Care Medicine, Vienna (Austria); Weber, Michael [Medical University of Vienna, Department of Radiology, Vienna (Austria)

    2011-09-15

    This study assessed the feasibility of telecytological evaluation of samples from CT-guided lung biopsies using a dynamic telecytological system in which the microscope was operated by personnel from the radiology department at the site of the biopsy and a cytologist off-site diagnosed the biopsy sample. 45 imprint samples from CT-guided biopsies of lung lesions were reviewed by two cytologists using a telecytological microscope (Olympus BX51, Tokyo, Japan). The telecytological microscope was operated by one radiologist and one radiology technician. The cytological samples were classified by a cytologist into four categories: benign, malignant, atypical cells of undetermined significance, and non-diagnostic. The results were compared with those of a previous consensus reading of two independent cytologists (gold standard). When the radiologist was operating the microscope, the diagnostic accuracy was 100% as both cytologists came to the correct diagnosis in all samples. When the technician operated the microscope, two diagnoses of cyotologist 1 differed from the gold standard. Thus, the accuracy for the technician was 95.56%. Telecytological evaluation of imprint samples from CT-guided lung biopsies is feasible because it can be performed with high diagnostic accuracy if personnel from the radiology department operate the microscope. (orig.)

  18. Bacterial migration through punctured surgical gloves under real surgical conditions

    Directory of Open Access Journals (Sweden)

    Heidecke Claus-Dieter

    2010-07-01

    Full Text Available Abstract Background The aim of this study was to confirm recent results from a previous study focussing on the development of a method to measure the bacterial translocation through puncture holes in surgical gloves under real surgical conditions. Methods An established method was applied to detect bacterial migration from the operating site through the punctured glove. Biogel™ double-gloving surgical gloves were used during visceral surgeries over a 6-month period. A modified Gaschen-bag method was used to retrieve organisms from the inner glove, and thus-obtained bacteria were compared with micro-organisms detected by an intra-operative swab. Results In 20 consecutive procedures, 194 gloves (98 outer gloves, 96 inner gloves were examined. The rate of micro-perforations of the outer surgical glove was 10% with a median wearing time of 100 minutes (range: 20-175 minutes. Perforations occurred in 81% on the non-dominant hand, with the index finger most frequently (25% punctured. In six cases, bacterial migration could be demonstrated microbiologically. In 5% (5/98 of outer gloves and in 1% (1/96 of the inner gloves, bacterial migration through micro-perforations was observed. For gloves with detected micro-perforations (n = 10 outer layers, the calculated migration was 50% (n = 5. The minimum wearing time was 62 minutes, with a calculated median wearing time of 71 minutes. Conclusions This study confirms previous results that bacterial migration through unnoticed micro-perforations in surgical gloves does occur under real practical surgical conditions. Undetected perforation of surgical gloves occurs frequently. Bacterial migration from the patient through micro-perforations on the hand of surgeons was confirmed, limiting the protective barrier function of gloves if worn over longer periods.

  19. A preoperative mathematic model for computed tomographic guided microwave ablation treatment of hepatic dome tumors.

    Science.gov (United States)

    Gao, Fei; Wang, Guo-Bao; Xiang, Zhan-Wang; Yang, Bin; Xue, Jing-Bing; Mo, Zhi-Qiang; Zhong, Zhi-Hui; Zhang, Tao; Zhang, Fu-Jun; Fan, Wei-Jun

    2016-05-03

    This study sought to prospectively evaluate the feasibility and safety of a preoperative mathematic model for computed tomographic(CT) guided microwave(MW) ablation treatment of hepatic dome tumors. This mathematic model was a regular cylinder quantifying appropriate puncture routes from the bottom up. A total of 103 patients with hepatic dome tumors were enrolled and randomly divided into 2 groups based on whether this model was used or not: Group A (using the model; n = 43) versus Group B (not using the model; n = 60). All tumors were treated by CT-guided MW ablation and follow-up contrast CT were reviewed. The average number of times for successful puncture, average ablation time, and incidence of right shoulder pain were less in Group A than Group B (1.4 vs. 2.5, P = 0.001; 8.8 vs. 11.1 minutes, P = 0.003; and 4.7% vs. 20%, P = 0.039). The technical success rate was higher in Group A than Group B (97.7% vs. 85.0%, P = 0.032). There were no significant differences between the two groups in primary and secondary technique efficacy rates (97.7% vs. 88.3%, P = 0.081; 90.0% vs. 72.7%, P = 0.314). No major complications occurred in both groups. The mathematic model of regular cylinder is feasible and safe for CT-guided MW ablation in treating hepatic dome tumors.

  20. Sample Size in Qualitative Interview Studies: Guided by Information Power.

    Science.gov (United States)

    Malterud, Kirsti; Siersma, Volkert Dirk; Guassora, Ann Dorrit

    2015-11-27

    Sample sizes must be ascertained in qualitative studies like in quantitative studies but not by the same means. The prevailing concept for sample size in qualitative studies is "saturation." Saturation is closely tied to a specific methodology, and the term is inconsistently applied. We propose the concept "information power" to guide adequate sample size for qualitative studies. Information power indicates that the more information the sample holds, relevant for the actual study, the lower amount of participants is needed. We suggest that the size of a sample with sufficient information power depends on (a) the aim of the study, (b) sample specificity, (c) use of established theory, (d) quality of dialogue, and (e) analysis strategy. We present a model where these elements of information and their relevant dimensions are related to information power. Application of this model in the planning and during data collection of a qualitative study is discussed. © The Author(s) 2015.

  1. Blood sampling and hemolysis affect concentration of plasma metabolites

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Pedersen, Lene Juul; Jensen, Margit Bak

    2012-01-01

    design and blood was collected after restraint via vein puncture 1, 4, 11, and 23 h after morning feeding. Plasma samples were categorized as without or with minor or major hemolysis [clear (n = 218), yellow (n = 97), or red (n = 37)] upon centrifugation. Plasma NEFA (P ...Two experiments were carried out to reveal and quantify plasma metabolites that are sensitive to hemolysis and animal stress due to the blood sampling procedure (vein puncture vs. catheter). In Exp. 1, 48 sows were fed 4 diets either once (0800 h) or twice daily (0800 h and 1500 h) in a crossover......, a subset of samples from 24 sows fed twice daily in Exp. 1 was combined with data obtained from 30 sows sampled using jugular vein catheters. All sows in Exp. 2 were fed twice daily (0800 h and 1500 h) and blood samples collected repeatedly 1, 4, 11, and 23 h after morning feeding (other conditions were...

  2. Significant Improvement of Puncture Accuracy and Fluoroscopy Reduction in Percutaneous Transforaminal Endoscopic Discectomy With Novel Lumbar Location System: Preliminary Report of Prospective Hello Study.

    Science.gov (United States)

    Fan, Guoxin; Guan, Xiaofei; Zhang, Hailong; Wu, Xinbo; Gu, Xin; Gu, Guangfei; Fan, Yunshan; He, Shisheng

    2015-12-01

    Prospective nonrandomized control study.The study aimed to investigate the implication of the HE's Lumbar LOcation (HELLO) system in improving the puncture accuracy and reducing fluoroscopy in percutaneous transforaminal endoscopic discectomy (PTED).Percutaneous transforaminal endoscopic discectomy is one of the most popular minimally invasive spine surgeries that heavily depend on repeated fluoroscopy. Increased fluoroscopy will induce higher radiation exposure to surgeons and patients. Accurate puncture in PTED can be achieved by accurate preoperative location and definite trajectory.The HELLO system mainly consists of self-made surface locator and puncture-assisted device. The surface locator was used to identify the exact puncture target and the puncture-assisted device was used to optimize the puncture trajectory. Patients who had single L4/5 or L5/S1 lumbar intervertebral disc herniation and underwent PTED were included the study. Patients receiving the HELLO system were assigned in Group A, and those taking conventional method were assigned in Group B. Study primary endpoint was puncture times and fluoroscopic times, and the secondary endpoint was location time and operation time.A total of 62 patients who received PTED were included in this study. The average age was 45.35 ± 8.70 years in Group A and 46.61 ± 7.84 years in Group B (P = 0.552). There were no significant differences in gender, body mass index, conservative time, and surgical segment between the 2 groups (P > 0.05). The puncture times were 1.19 ± 0.48 in Group A and 6.03 ± 1.87 in Group B (P HELLO system is accurate preoperative location and definite trajectory. This preliminary report indicated that the HELLO system significantly improves the puncture accuracy of PTED and reduces the fluoroscopic times, preoperative location time, as well as operation time. (ChiCTR-ICR-15006730).

  3. Ultrasound-guided pigtail catheters for drainage of various pleural diseases.

    Science.gov (United States)

    Liu, Yi-Heng; Lin, Yu-Chao; Liang, Shinn-Jye; Tu, Chih-Yen; Chen, Chia-Hung; Chen, Hung-Jen; Chen, Wei; Shih, Chuen-Ming; Hsu, Wu-Huei

    2010-10-01

    Little is known about the efficacy and safety of ultrasound-guided pigtail catheters for the management of various pleural diseases in the emergency department, ward, and intensive care unit. We conducted a retrospective study in a university hospital during a 1-year interval. A total of 276 patients (178 men and 98 women) underwent 332 pigtail catheters (the drain size ranged from 10F to 16F) under ultrasound guidance. The mean ± SEM patient age was 59 ± 18 years, and mean duration of drainage was 6.1 ± 2 days. A total of 64 drains (19.2%) were inserted for pneumothoraces; 98 drains (29.5%), for malignant effusions; 119 drains (35.8%), for parapneumonic effusions/empyemas; and 38 drains (11.4%), for massive transudate pleural effusions. The overall success rate was 72.9%. The success rate was highest when the drain was used to treat massive transudate effusions (81.6%) and malignant pleural effusions (75.5%), followed by parapneumonic effusions/empyemas (72.2%), hemothoraces (66.6%), and pneumothoraces (64.0%). Only 10 (3.0%) drains had complications due to the procedure, including infection (n = 4, 1.2%), dislodgment (n = 4, 1.2%), wound bleeding at the pigtail catheter puncture area complicated with hemothoraces (n = 1, 0.3%), and lung puncture (n = 1, 0.3%). There was no significant difference in success rate when different catheter sizes were used to treat pleural diseases. Ultrasound-guided pigtail catheters provide a safe and effective method of draining various pleural diseases. We strongly suggest that ultrasound-guided pigtail catheters be considered as the initial draining method for a variety of pleural diseases. Copyright © 2010 Elsevier Inc. All rights reserved.

  4. Morphologic features of puncture sites after exoseal vascular closure device implantation: Changes on follow-up computed tomography

    International Nuclear Information System (INIS)

    Ryu, Hwa Seong; Jang, Joo Yeon; Kim, Tae Un; Lee, Jun Woo; Park, Jung Hwan; Choo, Ki Seok; Cho, Mong; Yoon, Ki Tae; Hong, Young Ki; Jeon, Ung Bae

    2017-01-01

    The study aimed to evaluate the morphologic changes in transarterial chemoembolization (TACE) puncture sites implanted with an ExoSeal vascular closure device (VCD) using follow-up computed tomography (CT). 16 patients who used ExoSeal VCD after TACE were enrolled. Using CT images, the diameters and anterior wall thicknesses of the puncture sites in the common femoral artery (CFA) were compared with those of the contralateral CFA before TACE, at 1 month after every TACE session, and at the final follow-up period. The rates of complications were also evaluated. There were no puncture- or VCD-related complications. Follow-up CT images of the CFA's of patients who used ExoSeal VCDs showed eccentric vascular wall thickening with soft-tissue densities considered to be hemostatic plugs. Final follow-up CT images (mean, 616 days; range, 95–1106 days) revealed partial or complete resorption of the hemostatic plugs. The CFA puncture site diameters did not differ statistically from those of the contralateral CFA on the final follow-up CT (p > 0.05), regardless of the number of VCDs used. Follow-up CT images of patients who used ExoSeal VCDs showed no significant vascular stenosis or significant vessel wall thickening

  5. Morphologic features of puncture sites after exoseal vascular closure device implantation: Changes on follow-up computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Hwa Seong; Jang, Joo Yeon; Kim, Tae Un; Lee, Jun Woo; Park, Jung Hwan; Choo, Ki Seok; Cho, Mong; Yoon, Ki Tae; Hong, Young Ki; Jeon, Ung Bae [Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of)

    2017-05-15

    The study aimed to evaluate the morphologic changes in transarterial chemoembolization (TACE) puncture sites implanted with an ExoSeal vascular closure device (VCD) using follow-up computed tomography (CT). 16 patients who used ExoSeal VCD after TACE were enrolled. Using CT images, the diameters and anterior wall thicknesses of the puncture sites in the common femoral artery (CFA) were compared with those of the contralateral CFA before TACE, at 1 month after every TACE session, and at the final follow-up period. The rates of complications were also evaluated. There were no puncture- or VCD-related complications. Follow-up CT images of the CFA's of patients who used ExoSeal VCDs showed eccentric vascular wall thickening with soft-tissue densities considered to be hemostatic plugs. Final follow-up CT images (mean, 616 days; range, 95–1106 days) revealed partial or complete resorption of the hemostatic plugs. The CFA puncture site diameters did not differ statistically from those of the contralateral CFA on the final follow-up CT (p > 0.05), regardless of the number of VCDs used. Follow-up CT images of patients who used ExoSeal VCDs showed no significant vascular stenosis or significant vessel wall thickening.

  6. Sudden headache, lumbar puncture, and the diagnosis of subarachnoid hemorrhage in patients with a normal computed tomography scans.

    Science.gov (United States)

    Valle Alonso, Joaquín; Fonseca Del Pozo, Francisco Javier; Vaquero Álvarez, Manuel; De la Fuente Carillo, Juan José; Llamas, José Carlos; Hernández Montes, Yelda

    2018-02-01

    To assess the usefulness of computed tomography (CT) to identify subarachnoid bleeding in patients with neurologic deficits seeking emergency care for sudden headache within 6 hours of onset of symptoms. Retrospective observational study of patients presenting with sudden nontraumatic headache peaking during the previous hour in the absence of neurologic deficits. We ordered CT scans for all patients, and if the scan was normal we performed a lumbar puncture. All patients were then followed for 6 months. Eighty-five patients were included. Subarachnoid bleeding was identified in 10 (10.2%) patients by CT. Seventy- four lumbar punctures were performed in patients with negative CTs; the lumbar puncture was positive in 1 patient and inconclusive in 2 patients. In all 3 patients, bleeding was ruled out with later images; thus, no cases of subarachnoid hemorrhage were confirmed in the 74 patients who underwent lumbar puncture. Nor were any cases found in any of these patients during follow-up. A CT scan taken within 6 hours of onset of sudden headache is sufficient for confirming or ruling out subarachnoid bleeding in patients with sudden headache who have no neurologic deficits.

  7. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  8. Laboratory Guide for Residual Stress Sample Alignment and Experiment Planning-October 2011 Version

    Energy Technology Data Exchange (ETDEWEB)

    Cornwell, Paris A [ORNL; Bunn, Jeffrey R [ORNL; Schmidlin, Joshua E [ORNL; Hubbard, Camden R [ORNL

    2012-04-01

    The December 2010 version of the guide, ORNL/TM-2008/159, by Jeff Bunn, Josh Schmidlin, Camden Hubbard, and Paris Cornwell, has been further revised due to a major change in the GeoMagic Studio software for constructing a surface model. The Studio software update also includes a plug-in module to operate the FARO Scan Arm. Other revisions for clarity were also made. The purpose of this revision document is to guide the reader through the process of laser alignment used by NRSF2 at HFIR and VULCAN at SNS. This system was created to increase the spatial accuracy of the measurement points in a sample, reduce the use of neutron time used for alignment, improve experiment planning, and reduce operator error. The need for spatial resolution has been driven by the reduction in gauge volumes to the sub-millimeter level, steep strain gradients in some samples, and requests to mount multiple samples within a few days for relating data from each sample to a common sample coordinate system. The first step in this process involves mounting the sample on an indexer table in a laboratory set up for offline sample mounting and alignment in the same manner it would be mounted at either instrument. In the shared laboratory, a FARO ScanArm is used to measure the coordinates of points on the sample surface ('point cloud'), specific features and fiducial points. A Sample Coordinate System (SCS) needs to be established first. This is an advantage of the technique because the SCS can be defined in such a way to facilitate simple definition of measurement points within the sample. Next, samples are typically mounted to a frame of 80/20 and fiducial points are attached to the sample or frame then measured in the established sample coordinate system. The laser scan probe on the ScanArm can then be used to scan in an 'as-is' model of the sample as well as mounting hardware. GeoMagic Studio 12 is the software package used to construct the model from the point cloud the

  9. Laboratory Guide for Residual Stress Sample Alignment and Experiment Planning-October 2011 Version

    International Nuclear Information System (INIS)

    Cornwell, Paris A.; Bunn, Jeffrey R.; Schmidlin, Joshua E.; Hubbard, Camden R.

    2012-01-01

    The December 2010 version of the guide, ORNL/TM-2008/159, by Jeff Bunn, Josh Schmidlin, Camden Hubbard, and Paris Cornwell, has been further revised due to a major change in the GeoMagic Studio software for constructing a surface model. The Studio software update also includes a plug-in module to operate the FARO Scan Arm. Other revisions for clarity were also made. The purpose of this revision document is to guide the reader through the process of laser alignment used by NRSF2 at HFIR and VULCAN at SNS. This system was created to increase the spatial accuracy of the measurement points in a sample, reduce the use of neutron time used for alignment, improve experiment planning, and reduce operator error. The need for spatial resolution has been driven by the reduction in gauge volumes to the sub-millimeter level, steep strain gradients in some samples, and requests to mount multiple samples within a few days for relating data from each sample to a common sample coordinate system. The first step in this process involves mounting the sample on an indexer table in a laboratory set up for offline sample mounting and alignment in the same manner it would be mounted at either instrument. In the shared laboratory, a FARO ScanArm is used to measure the coordinates of points on the sample surface ('point cloud'), specific features and fiducial points. A Sample Coordinate System (SCS) needs to be established first. This is an advantage of the technique because the SCS can be defined in such a way to facilitate simple definition of measurement points within the sample. Next, samples are typically mounted to a frame of 80/20 and fiducial points are attached to the sample or frame then measured in the established sample coordinate system. The laser scan probe on the ScanArm can then be used to scan in an 'as-is' model of the sample as well as mounting hardware. GeoMagic Studio 12 is the software package used to construct the model from the point cloud the scan arm creates. Once

  10. Oviposition punctures in cucurbit fruits and their economic damage caused by the sterile female melon fly, Bactrocera cucurbitae Coquillett

    International Nuclear Information System (INIS)

    Miyatake, T.; Irabu, T.; Higa, R.

    1993-01-01

    Oviposition punctures caused by sterile females of the tephritid Bactrocera cucurbitae in cucurbit fruits were examined and economic damage was evaluated in Okinawa, Ryukyu Archipelago, Japan. Cage experiments in the field confirmed that sterile females make punctures (sterile stings) on fruits. The features of sterile stings differed depending on fruit species and were classified into 5 types

  11. EUS-guided biliary rendezvous using a short hydrophilic guidewire.

    Science.gov (United States)

    Dhir, Vinay; Kwek, Boon Eu Andrew; Bhandari, Suryaprakash; Bapat, Mukta; Maydeo, Amit

    2011-10-01

    BACKGROUND AND STUDY AIMS: EUS-guided rendezvous technique for biliary access requires expert manipulation of the guidewire across the downstream stricture or papilla. Published literature reports usage of the long-wire system to prevent loss of wire during scope exchange. We studied the efficacy of using a short hydrophilic guidewire in EUS-guided rendezvous. PATIENTS AND METHODS: This is a retrospective study conducted in a tertiary care referral centre. 15 patients underwent EUS-guided biliary rendezvous with short wire. EUS-guided transduodenal/transgastric puncture of the biliary system was performed, followed by anterograde placement of a hydrophilic short-wire (260 cm) across the downstream stricture and/or papilla. Retrograde access was then achieved by retrieving the trans-papillary wire, followed by standard ERCP intervention. Main outcome measurements were rates of procedural success and complications. RESULTS: EUS-guided biliary rendezvous was successful in 14 patients (93.3%). Failure was seen in one patient due to a tight malignant biliary stricture. One patient had peri-choledochal bile tracking which did not require any specific treatment. CONCLUSIONS: Short-wire system in EUS-guided biliary rendezvous is highly effective and safe. It is a useful salvage procedure for biliary cannulation in patients with accessible papilla.

  12. Headache in the parturient: Pathophysiology and management of post-dural puncture headache

    Directory of Open Access Journals (Sweden)

    Gita Nath

    2011-01-01

    Full Text Available Headache in the postpartum period is common and multifactorial in origin. Apart from primary causes such as tension headaches and migraine, secondary headaches such as post-dural puncture headache (PDPH are increasingly common because of increasing use of regional anaesthesia and analgesia during childbirth. Preventive measures for PDPH include the use of smaller gauge pencil-point needles for spinal blocks; epidural needles of 18 G or less; using saline rather than air for epidural space identification and the use of ultrasound guidance, especially for difficult cases such as morbid obesity and spinal deformities. In case of accidental dural puncture (ADP, the choice is between inserting the catheter in an adjacent space or intrathecal catheterization. Current evidence seems to be in favour of inserting the epidural catheter into the subarachnoid space and using the intrathecal catheter for analgesia/anaesthesia after prominently labelling it as intrathecal, to prevent misuse. It should be removed after at least 24 hours and a 10 ml bolus of saline injected before removal of catheter may be helpful. Either way, having written protocols for the management of accidental dural puncture helps to reduce the incidence of PDPH. PDPH can be disabling in severity and can mar the whole experience of childbirth. In addition, severe untreated PDPH can cause complications such as nerve palsies, subdural hematoma and cerebral venous thrombosis. Conservative methods of treatment should be tried first such as adequate hydration, paracetamol, caffeine, sumatriptan or ACTH/hydrocortisone. Epidural blood patching is the most effective treatment for PDPH. It is more effective if done 24-48 hours after dural puncture. It is an invasive procedure with its own complications as well as a failure rate of up to 30%, so that a second or even third patch may be necessary. Both these facts should be intimated to the patient beforehand. Meticulous follow-up and evaluation

  13. Clinical Value of CT-Guided Needle Biopsy for Retroperitoneal Lesions

    International Nuclear Information System (INIS)

    Tomozawa, Yuki; Inaba, Yoshitaka; Yamaura, Hidekazu; Sato, Yozo; Kato, Mina; Kanamoto, Takaaki; Sakane, Makoto

    2011-01-01

    The purpose of this study was to investigate retrospectively the clinical procedural performance of CT-guided needle biopsy for retroperitoneal lesions. CT-guided needle biopsy was performed in 74 consecutive patients (M:F = 44:30; mean age, 59.7 years) with retroperitoneal lesions between April 1998 and June 2009. The target lesion ranged from 1.5 to 12.5 cm in size. The biopsy access path ranged from 3.5 to 11.5 cm in depth. A biopsy specimen was obtained using an 18-gauge core needle under a CT or CT-fluoroscopy guidance and with the patient under local anesthesia. The histopathological diagnoses from the biopsies were obtained. The diagnostic confirmation of the subtype of lymphoma was evaluated. Satisfactory biopsy samples were obtained in 73 (99%) of 74 patients and a pathological diagnosis was made in 70 (95%) of 74 patients. Sixty three lesions were malignant (45 lymphomas, nine primary tumors, nine lymph node metastases) and seven were benign. The subtype of lymphoma was specified in 43 (96%) of 45 patients who were diagnosed with lymphoma. Analysis of the value of CT-guided biopsy in this series indicated 63 true positives, zero false positive, six true negatives and five false negatives. This test had a sensitivity of 93%, a specificity of 100% and an accuracy of 93%. No major complications were seen and minor complications were noted in seven patients (five with local hematomas, two with transient pain at the puncture site). CT-guided needle biopsy for retroperitoneal lesions is highly practical and useful, and particularly for determining the subtypes in patients with lymphoma.

  14. Guided episodic sampling for capturing and characterizing industrial plumes

    Science.gov (United States)

    Ou-Yang, Chang-Feng; Liao, Wei-Cheng; Chang, Chih-Chung; Hsieh, Hsin-Cheng; Wang, Jia-Lin

    2018-02-01

    An integrated sampling technique, dubbed trigger sampling, was developed to capture characteristic industrial emissions or plumes. In the field experiment, a hydrogen sulfide (H2S) analyzer was used as the triggering instrument at the boundary of a refinery plant due to frequent complaints of foul smell from local residents. Ten episodic samples were captured when the H2S level surpassed the prescribed trigger level of 8.5 ppbv over a three-day period. Three non-episodic (blank) samples and 23 road-side samples were also collected for comparison. All the 36 flask samples were analyzed by gas chromatography-mass spectrometry/flame ionization detection (GC-MS/FID) for 108 volatile organic compounds (VOCs). The total VOC abundance of the event samples was exceedingly higher than the non-episodic samples by over 80 times in the extreme case. Alkanes were found to be the dominant constituents in the event samples, amounting to over 90% of the total VOC concentrations vs. only 30-40% for the blank and metropolitan samples. In addition, light alkanes in the event samples were highly correlated with the trigger species H2S (R2 = 0.82), implying their common origin. The matrix of chemical composition vs. sample types permitted easy visualization of the dominance of light alkanes for the event samples compared to other types of samples. Principle component analysis (PCA) identified two major contributors to cover 93% of the total variance arising from the 36 samples, further quantifying the distinction of the triggered episodic samples from the contrast samples. The proposed trigger sampling is a coupling of fast-and-slow measurement techniques. In this example, the fast-response H2S analyzer served to "guide" sampling to capture industrial plumes which were then characterized by a relatively slow method of GC-MS/FID for detailed chemical composition representative of the prominent sources.

  15. Cervical myelography via C1/C2 lateral puncture

    International Nuclear Information System (INIS)

    Grange, B.

    1981-01-01

    The use of the water soluble, tri-iodinated contrast medium, metrizamide, in cervical myelography via C1/C2 lateral puncture is described. Details of the tomographic apparatus and the technique employed are given. The advantages of water soluble myelography using metrizamide are overwhelming due to its miscibility with CSF, improved anatomical demonstration, radiographic visualisation and diagnostic accuracy and advantageous pharmacological properties with reduced toxicity. This technique provided successful diagnoses in a series of 104 patients. (U.K.)

  16. Direct right ventricular puncture for hemodynamic evaluation of a mechanical tricuspid valve prosthesis: a new indication for an old procedure.

    Science.gov (United States)

    Gibson, M A; Carell, E S

    1997-11-01

    The advent of transvenous right heart catheterization has relegated direct transthoracic right ventricular puncture largely to the role of "interesting historical footnote." However, in the case of a right ventricle that is "protected" by a mechanical tricuspid valve prosthesis, direct right ventricular puncture represents a reasonable alternative for obtaining accurate hemodynamic information.

  17. Reinvestigation of moving punctured black holes with a new code

    International Nuclear Information System (INIS)

    Cao Zhoujian; Yo Hweijang; Yu Juiping

    2008-01-01

    We report on our code, in which the moving puncture method is applied and an adaptive/fixed mesh refinement is implemented, and on its preliminary performance on black hole simulations. Based on the Baumgarte-Sharpiro-Shibata-Nakamura (BSSN) formulation, up-to-date gauge conditions and the modifications of the formulation are also implemented and tested. In this work, we present our primary results about the simulation of a single static black hole, of a moving single black hole, and of the head-on collision of a binary black hole system. For the static punctured black hole simulations, different modifications of the BSSN formulation are applied. It is demonstrated that both the currently used sets of modifications lead to a stable evolution. For cases of a moving punctured black hole with or without spin, we search for viable gauge conditions and study the effect of spin on the black hole evolution. Our results confirm previous results obtained by other research groups. In addition, we find a new gauge condition, which has not yet been adopted by any other researchers, which can also give stable and accurate black hole evolution calculations. We examine the performance of the code for the head-on collision of a binary black hole system, and the agreement of the gravitational waveform it produces with that obtained in other works. In order to understand qualitatively the influence of matter on the binary black hole collisions, we also investigate the same head-on collision scenarios but perturbed by a scalar field. The numerical simulations performed with this code not only give stable and accurate results that are consistent with the works by other numerical relativity groups, but also lead to the discovery of a new viable gauge condition, as well as clarify some ambiguities in the modification of the BSSN formulation. These results demonstrate that this code is reliable and ready to be used in the study of more realistic astrophysical scenarios and of numerical

  18. Efficacy and safety of radiofrequency ablation of hepatocellular carcinoma in the hepatic dome with the CT-guided extrathoracic transhepatic approach

    International Nuclear Information System (INIS)

    Kim, Young Kon; Kim, Chong Soo; Lee, Jeong Min; Chung, Gyung Ho; Chon, Su Bin

    2006-01-01

    Purpose: The purpose of this study was to determine the efficacy and safety of radiofrequency (RF) ablation for the treatment of hepatocellular carcinoma (HCC) in the hepatic dome with CT-guided extrathoracic transhepatic approach. Materials and methods: Fifteen patients with 15 HCCs (size range: 0.8-4 cm, mean size: 1.8 cm) in the hepatic dome were treated by RF ablation using cooled-tip electrodes and with CT-guided extrathoracic transhepatic approach. Therapeutic response of the tumor to RF ablation and procedure-related complications including hepatic injury, hemoperitoneum, and thermal injury of diaphragm were evaluated. Results: The average number of needle punctures to ensure the correct needle position in the targeted tumor was 3.7 (range: 1-6 punctures). The average ablation time was 14.7 min (range: 8-25 min). Complete necrosis without marginal recurrence after at least 13-month follow-up was attained in 13 tumors (86.7%). There were no major complications related to the procedures. Six patients had shoulder pain that lasted three days to two weeks after the procedures and their symptoms were resolved with conservative treatment. Conclusions: RF ablation using CT-guided extrathoracic transhepatic approach is an effective and safe technique for the treatment of HCC in the hepatic dome

  19. Classifier-guided sampling for discrete variable, discontinuous design space exploration: Convergence and computational performance

    Energy Technology Data Exchange (ETDEWEB)

    Backlund, Peter B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Shahan, David W. [HRL Labs., LLC, Malibu, CA (United States); Seepersad, Carolyn Conner [Univ. of Texas, Austin, TX (United States)

    2014-04-22

    A classifier-guided sampling (CGS) method is introduced for solving engineering design optimization problems with discrete and/or continuous variables and continuous and/or discontinuous responses. The method merges concepts from metamodel-guided sampling and population-based optimization algorithms. The CGS method uses a Bayesian network classifier for predicting the performance of new designs based on a set of known observations or training points. Unlike most metamodeling techniques, however, the classifier assigns a categorical class label to a new design, rather than predicting the resulting response in continuous space, and thereby accommodates nondifferentiable and discontinuous functions of discrete or categorical variables. The CGS method uses these classifiers to guide a population-based sampling process towards combinations of discrete and/or continuous variable values with a high probability of yielding preferred performance. Accordingly, the CGS method is appropriate for discrete/discontinuous design problems that are ill-suited for conventional metamodeling techniques and too computationally expensive to be solved by population-based algorithms alone. In addition, the rates of convergence and computational properties of the CGS method are investigated when applied to a set of discrete variable optimization problems. Results show that the CGS method significantly improves the rate of convergence towards known global optima, on average, when compared to genetic algorithms.

  20. CT-guided periradicular therapy in cervical and lumbar radicular syndromes

    International Nuclear Information System (INIS)

    Nian Dingfang; Zhou Jun; Li Wenhua; Cao Qingxuan; Xia Baosu; Apitzsch, D.E.

    2007-01-01

    Objective: To evaluate the effectiveness of CT-guided periradicular therapy (PRT) in cervical and lumber radicular syndromes. Methods: Seventy two cases of cervical and lumbar radicular syndromes were treated by CT-guided PRT. During PRT, 10-20 mg of Triamhexal and 3-4 ml of Carbostesin 0.25%(Bupivacainhydrochlorid) were injected into the space around the corresponding spinal root, once a week, all together six times as a course. Results: Four hundreds and forty six PRT procedures were carried out in 72 patients having a successful puncture and a satisfying spread of Triamhexal and Carbostesin around the spinal nerve root space for every time. After 6 to 24 months follow up, 62 patients showed a significant pain reduction or complete disappearance. Moderate improvement was not noted in 6 and no improvement in 4. The effective rate was 94.4% without any correlative complication. Conclusions: CT-guided PRT is an effective, easy and safe procedure to treat patients with refractory cervical or lumbar radicular pain syndromes. (authors)

  1. Cerebral venous and sinus thrombosis with cerebrospinal fluid circulation block after the first methotrexate administration by lumbar puncture

    International Nuclear Information System (INIS)

    Bienfait, H.P.; Gijtenbeek, J.M.M.; Bent, M.J. van; Bruin, H.G. de; Voogt, P.J.; Pillay, M.

    2002-01-01

    We report a patient treated for small lymphocytic lymphoma/leukemia with cerebral venous and sinus thrombosis (CVST) after lumbar puncture with intrathecal administration of methotrexate (MTX). He also developed a cerebrospinal fluid flow block. This is the first report of an association between lumbar puncture and intrathecally administered MTX and the development of CVST. Intrathecal treatment in this patient was discontinued and he was successfully treated with high-dose low-molecular-weight heparin subcutaneously. (orig.)

  2. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  3. Experience and nursing needs of school-age children undergoing lumbar puncture during the treatment of acute lymphoblastic leukaemia: a descriptive and qualitative study.

    Science.gov (United States)

    Xie, Anwei; Shan, Yuying; Niu, Mei E; Chen, Yi; Wang, Xiya

    2017-11-01

    To describe experiences and nursing needs of school-age Chinese children undergoing lumbar puncture for the treatment of acute lymphoblastic leukaemia. Lumbar puncture is an invasive procedure, causing psychological changes and physical discomfort in patients. In a previous study, it was proved that distraction intervention, such as music therapy, relieves pain and anxiety. There is limited evidence regarding the experience and needs of school-age children during lumbar puncture after being diagnosed with acute lymphoblastic leukaemia. To minimise their anxiety and pain during the procedure, it is important to collect information directly from these children. A descriptive qualitative research. Twenty-one school-age children with acute lymphoblastic leukaemia participated in semi-structured interviews at a Children's Hospital in China. Data were collected by an experienced and trained interviewer. Qualitative content analysis was chosen to describe experiences of children undergoing lumbar puncture. While undergoing lumbar puncture for the treatment of acute lymphoblastic leukaemia, school-age Chinese children experienced complex psychological feelings (fear, tension, helplessness, sadness and anxiety). They also experienced physical discomfort. They had multipolar needs, such as information, communication, respect, self-actualisation, environment and equipment. This study identified important areas that must be closely monitored by healthcare staff, performing lumbar puncture on acute lymphoblastic leukaemia children. Thus, a successful and smooth procedure can be performed on these patients, and their quality of life can be improved. The experiences described in this study contribute to a better understanding of the needs of acute lymphoblastic leukaemia children undergoing lumbar puncture. They also provide valuable information to professional medical care staff that develops future nursing assessments. © 2016 John Wiley & Sons Ltd.

  4. CT-guided percutaneous vertebroplasty for the treatment of metastases in the cervical spine

    International Nuclear Information System (INIS)

    Wang Jianhua; Wang Zhentang; Zuo Changjing; Shao Chenwei; Chen Wei; Lv Taozhen; Dong Aisheng

    2009-01-01

    Objective: To assess the clinical efficacy and complications of CT-guided percutaneous vertebroplasty in the treatment of metastases of the cervical spine, and to discuss the proper needle path for different cervical vertebra. Methods: CT-guided percutaneous vertebroplasty was performed in 17 patients with cervical vertebral metastatic neoplasm, and the results of the treatment were retrospectively analyzed. Close observation was carded out after the procedure and a follow-up of 3-17 months was conducted. A comparison of the visual analogue pain scale (VAS) and Frankel's classification between pre-and post- operation was made. The occurrence of complications was recorded. The optimal needle path was summarized. Results: (1) The successful puncture was achieved in all 17 cases. The needle pathway included: the front of carotid sheath (n=4), between carotid sheath and vertebral artery (n=11) and behind the vertebral artery and carotid sheath (n=2). (2) Before the procedure the VAS was 7.24 ± 1.01, and at the time of one hour, one week and three months after the procedure it was decreased to 3.24 ± 1.09, 2.40 ± 0.80 and 1.82 ± 0.53 respectively. Wilcoxon signed-rank test showed that the difference in VAS between pre-and post- operation was statistically significant (T=76.5, P 2 =4.52, P=0.033 and P<0.05 when Kruskal-Wallis test was adopted. (3) CT scanning immediately after the procedure showed that slight leakage of cement to the adjacent disc, epidural fat, parosteal tissue or to the needle path occurred in 35.3% with no serious complications. In a follow-up period of 3-17 months, the metastatic lesions remained stable in 14 cases (82.4%). Conclusion: (1) The optimal needle path for upper cervical vertebrae is posterolateral transpedicular approach while for the lower cervical vertebrae it is more reasonable to puncture via the front carotid sheath or between carotid sheath and vertebral artery. Nevertheless, the puncture pathway should be devised individually

  5. Experimental impact and puncture evaluation of the prototype quarter scale TRU transporter package

    International Nuclear Information System (INIS)

    Meyer, R.J.; Plonski, B.A.; Vigil, M.G.; Joseph, B.J.

    1983-01-01

    The impact tests consist of the TRUPACT model free-falling 9 meters onto a flat, horizontal, unyielding surface as specified in 10CFR71. The model was dropped at five different orientations including: (1) flat on the door end; (2) flat on the side; (3) center of gravity over impact corner; (4) flat on edge; and (5) corner impact edge slapdown. The model instrumentation for these tests included: (1) sixty strain gages located throughout the model structure used to obtain impact stresses; (2) three displacement transducers used to measure relative motion between the inner door and inner cavity frame structure (seal integrity); and (3) two triaxial accelerometers used to estimate the impact forces on the inner and outer frame structures. The drop/puncture tests consisted of the TRUPACT-I model free-falling one meter onto a 38-millimeter (1.5-inch) diameter mild steel punch 0.9 meters (36 inches) long. The punch was welded to an unyielding surface. Model drop/puncture orientations included: (1) flat on the model sides; (2) flat on the door and back ends; and (3) model center of gravity over impact point at various locations of the model (door end, back end, near door seals, near tubular frame structure, center of panels). The test results and subsequent analysis of the data have been used to support the final design of TRUPACT-I and to determine the most damaging impact and puncture orientations for testing the full scale prototype

  6. Detailed puncture analyses tank cars : analysis of different impactor threats and impact conditions.

    Science.gov (United States)

    2013-03-01

    There has been significant research in recent years to analyze and improve the impact behavior and puncture resistance of railroad tank cars. Much of this research has been performed using detailed nonlinear finite element analyses supported by full ...

  7. Emergency Medicine Myths: Computed Tomography of the Head Prior to Lumbar Puncture in Adults with Suspected Bacterial Meningitis - Due Diligence or Antiquated Practice?

    Science.gov (United States)

    April, Michael D; Long, Brit; Koyfman, Alex

    2017-09-01

    Various sources purport an association between lumbar puncture and brainstem herniation in patients with intracranial mass effect lesions. Several organizations and texts recommend head computed tomography (CT) prior to lumbar puncture in selected patients. To review the evidence regarding the utility of obtaining head CT prior to lumbar puncture in adults with suspected bacterial meningitis. Observational studies report a risk of post-lumbar puncture brainstem herniation in the presence of intracranial mass effect (1.5%) that is significantly lower than that reported among all patients with bacterial meningitis (up to 13.3%). It is unclear from existing literature whether identifying patients with intracranial mass effect decreases herniation risk. Up to 80% of patients with bacterial meningitis experiencing herniation have no CT abnormalities, and approximately half of patients with intracranial mass effect not undergoing lumbar puncture herniate. Decision rules to selectively perform CT on only those individuals most likely to have intracranial mass effect lesions have not undergone validation. Despite recommendations for immediate antimicrobial therapy prior to imaging, data indicate an association between pre-lumbar puncture CT and antibiotic delays. Recent data demonstrate shortened door-to-antibiotic times and lower mortality from bacterial meningitis after implementation of new national guidelines, which restricted generally accepted CT indications by removing impaired mental status as imaging criterion. Data supporting routine head CT prior to lumbar puncture are limited. Physicians should consider selective CT for those patients at risk for intracranial mass effect lesions based on decision rules or clinical gestalt. Patients undergoing head CT must receive immediate antibiotic therapy. Published by Elsevier Inc.

  8. X-ray targeting puncture collagenase chemonucleolysis combined with injection of medical ozone for the treatment of lumbar disc herniation

    International Nuclear Information System (INIS)

    Yao Lin; Zhu Genfa

    2011-01-01

    Objective: To evaluate the clinical value of X-ray target puncture collagenase chemonucleolysis combined with injection of medical ozone for lumbar disc herniation. Methods: One thousand and sixty-two cases of lumbar disc herniation accepted collagenase chemonucleolysis combined with injection of medical ozone targeted by X-ray. The therapeutic effects after operation were analyzed. Results: Of all the 1062 cases, the effective rate of X-ray target puncture collagenase chemonucleolysis combined with injection of medical ozone was 95.3% at 3 months, 92.3% at 12 months, and 91.2% at 24 months after operation. Conclusion: X-ray target puncture collagenase chemonucleolysis combined with injection of medical ozone is a simple and safe method for the lumbar disc herniation. It also had fewer adverse reactions and better therapeutic effects. (authors)

  9. Therapeutic effects of visual standard channel combined with F4.8 visual puncture super-mini percutaneous nephrolithotomy on multiple renal calculi.

    Science.gov (United States)

    Cui, Zhenyu; Gao, Yanjun; Yang, Wenzeng; Zhao, Chunli; Ma, Tao; Shi, Xiaoqiang

    2018-01-01

    To evaluate the therapeutic effects of visual standard channel combined with F4.8 visual puncture super-mini percutaneous nephrolithotomy (SMP) on multiple renal calculi. The clinical data of 46 patients with multiple renal calculi treated in Affiliated Hospital of Hebei University from October 2015 to September 2016 were retrospectively analyzed. There were 28 males and 18 females aged from 25 to 65 years old, with an average of 42.6. The stone diameters were 3.0-5.2 cm, (4.3 ± 0.8) cm on average. F4.8 visual puncture-assisted balloon expansion was used to establish a standard channel. After visible stones were removed through nephroscopy combined with ultrasound lithotripsy, the stones of other parts were treated through F4.8 visual puncture SMP with holmium laser. Indices such as the total time of channel establishment, surgical time, decreased value of hemoglobin, phase-I stone clearance rate and surgical complications were summarized. Single standard channel was successfully established in all cases with the assistance of F4.8 visual puncture, of whom 24 were combined with a single microchannel, 16 were combined with double microchannels, and six were combined with three microchannels. All patients were placed with nephrostomy tube which was not placed in the microchannels. Both F5 double J tubes were placed after surgery. The time for establishing a standard channel through F4.8 visual puncture was (6.8 ± 1.8) min, and that for establishing a single F4.8 visual puncture microchannel was (4.5 ± 0.9) min. The surgical time was (92 ± 15) min. The phase-I stone clearance rate was 91.3% (42/46), and the decreased value of hemoglobin was (12.21 ± 2.5) g/L. There were 8 cases of postoperative fever which was relieved after anti-inflammatory treatment. Four cases had 0.5-0.8 cm of stone residue in the lower calyx, and all stones were discharged one month after surgery by in vitro shock wave lithotripsy combined with position nephrolithotomy, without stone

  10. Approach to treatment for obstructive jaundice of PTCD guided by combining ultrasound with X-ray scan

    International Nuclear Information System (INIS)

    Tang Huanliang; Cao Haoqian; Fei Jianguo

    2008-01-01

    Objective: To investigate the technical and clinical value of PTCD in patients with obstructive jaundice by the guiding of ultrasound combined with X-ray scan. Methods PTCD was performed in 58 patients with obstructive jaundice, with 47 patients malignant diseases and 11 patients benign diseases, guided by combining ultrasound and X-ray scan. 51 patients were punctured to right bile ducts and 7 cases were left bile ducts. Cholangiography was routinely used. Results: Technical success was obtained in all patients. No bleeding and biliary peritonitis were found after procedures. The bilirubin was reduced by 75.4ummol/L one week after operation. Conclusion: The technique of PTCD guided by combining ultrasound with X-ray scan was safe, simple, cost saving and less complications for obstructive jaundice. (authors)

  11. US-guided placement of temporary internal jugular vein catheters: immediate technical success and complications in normal and high-risk patients

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Kara, Gulcan; Torun, Dilek; Kizilkilic, Osman; Yildirim, Tulin

    2005-01-01

    Objective: : To evaluate the technical success and immediate complication rates of temporary internal jugular vein (IJV) haemodialysis catheter placement in normal and high-risk patients. Methods and materials: Two-hundred and twenty temporary internal jugular vein catheters inserted under ultrasound guidance in 172 patients were prospectively analyzed. Of 172 patients, 93 (54%) were males and 79 (46%) were females (age range, 18-83; mean, 56.0 years). Of 220 catheters, 171 (78%) were placed in patients who had a risk factor for catheter placement like patients with disorder of haemostasis, poor compliance, and previous multiple catheter insertion in the same IJV. Forty-seven (21.3%) procedures were performed on bed-side. A catheter was inserted in the right IJV in 178 procedures (80.9%) and left IJV in 42 procedures. Of 172 patients, 112 (65%) had only one catheter placement and the rest had had more than one catheter placement (range, 1-5). Results: Technical success was achieved in all patients (100%). Average number of puncture was 1.24 (range, 1-3). One hundred and eighty-three insertions (83.1%) were single-wall punctures, whereas 37 punctures were double wall punctures. Nine (4%) minor complications were encountered. Inadvertent carotid artery puncture without a sequel in four procedures (1.8%), oozing of blood around the catheter in three procedures (1.4%), a small hematoma in one procedure (0.4%), and puncture through the pleura in one procedure (0.4%) without development of pneumothorax. Oozing of blood was seen only in patients with disorder of haemostasis. Conclusion: Ultrasound-guided placement of internal jugular vein catheters is very safe with very high success rate and few complications. It can safely be performed in high-risk patients, like patients with disorders of haemostasis and patients with previous multiple catheter insertion in the same vein

  12. Usefulness of real-time three-dimensional ultrasonography in percutaneous nephrostomy: an animal study.

    Science.gov (United States)

    Hongzhang, Hong; Xiaojuan, Qin; Shengwei, Zhang; Feixiang, Xiang; Yujie, Xu; Haibing, Xiao; Gallina, Kazobinka; Wen, Ju; Fuqing, Zeng; Xiaoping, Zhang; Mingyue, Ding; Huageng, Liang; Xuming, Zhang

    2018-05-17

    To evaluate the effect of real-time three-dimensional (3D) ultrasonography (US) in guiding percutaneous nephrostomy (PCN). A hydronephrosis model was devised in which the ureters of 16 beagles were obstructed. The beagles were divided equally into groups 1 and 2. In group 1, the PCN was performed using real-time 3D US guidance, while in group 2 the PCN was guided using two-dimensional (2D) US. Visualization of the needle tract, length of puncture time and number of puncture times were recorded for the two groups. In group 1, score for visualization of the needle tract, length of puncture time and number of puncture times were 3, 7.3 ± 3.1 s and one time, respectively. In group 2, the respective results were 1.4 ± 0.5, 21.4 ± 5.8 s and 2.1 ± 0.6 times. The visualization of needle tract in group 1 was superior to that in group 2, and length of puncture time and number of puncture times were both lower in group 1 than in group 2. Real-time 3D US-guided PCN is superior to 2D US-guided PCN in terms of visualization of needle tract and the targeted pelvicalyceal system, leading to quick puncture. Real-time 3D US-guided puncture of the kidney holds great promise for clinical implementation in PCN. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  13. Technical aspects of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline - March 2017.

    Science.gov (United States)

    Polkowski, Marcin; Jenssen, Christian; Kaye, Philip; Carrara, Silvia; Deprez, Pierre; Gines, Angels; Fernández-Esparrach, Gloria; Eisendrath, Pierre; Aithal, Guruprasad P; Arcidiacono, Paolo; Barthet, Marc; Bastos, Pedro; Fornelli, Adele; Napoleon, Bertrand; Iglesias-Garcia, Julio; Seicean, Andrada; Larghi, Alberto; Hassan, Cesare; van Hooft, Jeanin E; Dumonceau, Jean-Marc

    2017-10-01

    For routine EUS-guided sampling of solid masses and lymph nodes (LNs) ESGE recommends 25G or 22G needles (high quality evidence, strong recommendation); fine needle aspiration (FNA) and fine needle biopsy (FNB) needles are equally recommended (high quality evidence, strong recommendation).When the primary aim of sampling is to obtain a core tissue specimen, ESGE suggests using 19G FNA or FNB needles or 22G FNB needles (low quality evidence, weak recommendation).ESGE recommends using 10-mL syringe suction for EUS-guided sampling of solid masses and LNs with 25G or 22G FNA needles (high quality evidence, strong recommendation) and other types of needles (low quality evidence, weak recommendation). ESGE suggests neutralizing residual negative pressure in the needle before withdrawing the needle from the target lesion (moderate quality evidence, weak recommendation).ESGE does not recommend for or against using the needle stylet for EUS-guided sampling of solid masses and LNs with FNA needles (high quality evidence, strong recommendation) and suggests using the needle stylet for EUS-guided sampling with FNB needles (low quality evidence, weak recommendation).ESGE suggests fanning the needle throughout the lesion when sampling solid masses and LNs (moderate quality evidence, weak recommendation).ESGE equally recommends EUS-guided sampling with or without on-site cytologic evaluation (moderate quality evidence, strong recommendation). When on-site cytologic evaluation is unavailable, ESGE suggests performance of three to four needle passes with an FNA needle or two to three passes with an FNB needle (low quality evidence, weak recommendation).For diagnostic sampling of pancreatic cystic lesions without a solid component, ESGE suggests emptying the cyst with a single pass of a 22G or 19G needle (low quality evidence, weak recommendation). For pancreatic cystic lesions with a solid component, ESGE suggests sampling of the solid component using the same technique as in the

  14. Study of the damage rate caused by intervertebral foramen type inside and outside and the pass of the intervertebral DRG RF puncture way.

    Science.gov (United States)

    Sun, Jiashu; Zhang, Haitao

    2014-09-01

    This paper was to analyze and contrast the damage rate on the thoracic segment different position of the dorsal root ganglion(dorsal root ganglion, DRG) caused by different puncture path in radiofrequency ablation, thus the best RF target way for the thoracic segment of different types of DRG was confirmed. According to the difference of puncture and ablation damage way, 14 segmental spinal specimens were randomly divided into three groups, and then conducted DRG radiofrequency damage on percutaneous puncture path according to the type of DRG position.The damage effect of different puncture path by the judgment standard of the result of pathology analyzed. The experiment showed that RF damage of group A were 72.58 ± 18.88%, 54.16 ± 24.84% and 32.85 ± 28.11%; that of group B were 771.86 ± 15.15% and 72.02 ± 17.86%, 57.14 ± 18.02% and 52.47 ± 20.64%, 68.75 ± 14.63% and 71.78 ± 16.00%; and that of group C were 82.46 ± 14.10%, 81.53 ± 11.81% and 80.83 ± 13.33%. It was concluded that the singleness of DRG puncture route is one of the important reasons for the poor thoracic segments DRG radiofrequency (RF) ablation effect. While according to the type of DRG different positions with double joint puncture path can significantly improve the rate of DRG RF damage.

  15. Combined short- and long-axis ultrasound-guided central venous catheterization is superior to conventional techniques: A cross-over randomized controlled manikin trial.

    Directory of Open Access Journals (Sweden)

    Jun Takeshita

    Full Text Available Visualizing the needle tip using the short-axis (SA ultrasound-guided central venous catheterization approach can be challenging. It has been suggested to start the process with the SA approach and then switch to the long-axis (LA; however, to our knowledge, this combination has not been evaluated. We compared the combined short- and long-axis (SLA approach with the SA approach in a manikin study.We performed a prospective randomized controlled cross-over study in an urban emergency department and intensive care unit. Resident physicians in post-graduate years 1-2 performed a simulated ultrasound-guided internal jugular vein puncture using the SA and SLA approaches on manikins. Twenty resident physicians were randomly assigned to two equal groups: (1 one group performed punctures using the SA approach followed by SLA; and (2 the other performed the same procedures in the opposite order. We compared the success rate and procedure duration for the two approaches. Procedural success was defined as insertion of the guide-wire into the vein while visualizing the needle tip at the time of anterior wall puncture, without penetrating the posterior wall.Six resident physicians (30% performed both approaches successfully, while 12 (60% performed the SLA approach, but not the SA, successfully. Those who performed the SA approach successfully also succeeded with the SLA approach. Two resident physicians (10% failed to perform both approaches. The SLA approach had a significantly higher success rate than the SA approach (P < 0.001. The median (interquartile range procedure duration was 59.5 [46.0-88.5] seconds and 45.0 [37.5-84.0] seconds for the SLA and SA approaches, respectively. The difference of the duration between the two procedures was 15.5 [0-28.5] seconds. There was no significant difference in duration between the two approaches (P = 0.12.Using the SLA approach significantly improved the success rate of internal jugular vein puncture performed by

  16. The exchange algebra for Liouville theory on punctured Riemann sphere

    International Nuclear Information System (INIS)

    Shen Jianmin; Sheng Zhengmao

    1991-11-01

    We consider in this paper the classical Liouville field theory on the Riemann sphere with n punctures. In terms of the uniformization theorem of Riemann surface, we show explicitly the classical exchange algebra (CEA) for the chiral components of the Liouville fields. We find that the matrice which dominate the CEA is related to the symmetry of the Lie group SL(n) in a nontrivial manner with n>3. (author). 10 refs

  17. Mycobacterium ulcerans low infectious dose and mechanical transmission support insect bites and puncturing injuries in the spread of Buruli ulcer.

    Science.gov (United States)

    Wallace, John R; Mangas, Kirstie M; Porter, Jessica L; Marcsisin, Renee; Pidot, Sacha J; Howden, Brian; Omansen, Till F; Zeng, Weiguang; Axford, Jason K; Johnson, Paul D R; Stinear, Timothy P

    2017-04-01

    Addressing the transmission enigma of the neglected disease Buruli ulcer (BU) is a World Health Organization priority. In Australia, we have observed an association between mosquitoes harboring the causative agent, Mycobacterium ulcerans, and BU. Here we tested a contaminated skin model of BU transmission by dipping the tails from healthy mice in cultures of the causative agent, Mycobacterium ulcerans. Tails were exposed to mosquito (Aedes notoscriptus and Aedes aegypti) blood feeding or punctured with sterile needles. Two of 12 of mice with M. ulcerans contaminated tails exposed to feeding A. notoscriptus mosquitoes developed BU. There were no mice exposed to A. aegypti that developed BU. Eighty-eight percent of mice (21/24) subjected to contaminated tail needle puncture developed BU. Mouse tails coated only in bacteria did not develop disease. A median incubation time of 12 weeks, consistent with data from human infections, was noted. We then specifically tested the M. ulcerans infectious dose-50 (ID50) in this contaminated skin surface infection model with needle puncture and observed an ID50 of 2.6 colony-forming units. We have uncovered a biologically plausible mechanical transmission mode of BU via natural or anthropogenic skin punctures.

  18. Mycobacterium ulcerans low infectious dose and mechanical transmission support insect bites and puncturing injuries in the spread of Buruli ulcer.

    Directory of Open Access Journals (Sweden)

    John R Wallace

    2017-04-01

    Full Text Available Addressing the transmission enigma of the neglected disease Buruli ulcer (BU is a World Health Organization priority. In Australia, we have observed an association between mosquitoes harboring the causative agent, Mycobacterium ulcerans, and BU. Here we tested a contaminated skin model of BU transmission by dipping the tails from healthy mice in cultures of the causative agent, Mycobacterium ulcerans. Tails were exposed to mosquito (Aedes notoscriptus and Aedes aegypti blood feeding or punctured with sterile needles. Two of 12 of mice with M. ulcerans contaminated tails exposed to feeding A. notoscriptus mosquitoes developed BU. There were no mice exposed to A. aegypti that developed BU. Eighty-eight percent of mice (21/24 subjected to contaminated tail needle puncture developed BU. Mouse tails coated only in bacteria did not develop disease. A median incubation time of 12 weeks, consistent with data from human infections, was noted. We then specifically tested the M. ulcerans infectious dose-50 (ID50 in this contaminated skin surface infection model with needle puncture and observed an ID50 of 2.6 colony-forming units. We have uncovered a biologically plausible mechanical transmission mode of BU via natural or anthropogenic skin punctures.

  19. Gadolinium enhancement of spinal subdural collection on magnetic resonance imaging after lumbar puncture

    International Nuclear Information System (INIS)

    Teksam, Mehmet; Casey, Sean O.; McKinney, Alexander; Michel, Eduard; Truwit, Charles L.

    2003-01-01

    We report a 35-year-old male with an unusual contrast-enhancing sterile spinal subdural collection on magnetic resonance imaging (MRI), apparently occurring as a complication of lumbar puncture. Follow-up MRI after 4 weeks demonstrated spontaneous resolution of the collection without intervening treatment. (orig.)

  20. Equilibrium initial data for moving puncture simulations: the stationary 1 + log slicing

    International Nuclear Information System (INIS)

    Baumgarte, T W; Matera, K; Etienne, Z B; Liu, Y T; Shapiro, S L; Taniguchi, K; Murchadha, N O

    2009-01-01

    We discuss a 'stationary 1 + log' slicing condition for the construction of solutions to Einstein's constraint equations. For stationary spacetimes, these initial data give a stationary foliation when evolved with 'moving puncture' gauge conditions that are often used in black hole evolutions. The resulting slicing is time independent and agrees with the slicing generated by being dragged along a timelike Killing vector of the spacetime. When these initial data are evolved with moving puncture gauge conditions, numerical errors arising from coordinate evolution should be minimized. While these properties appear very promising, suggesting that this slicing condition should be an attractive alternative to, for example, maximal slicing, we demonstrate in this paper that solutions can be constructed only for a small class of problems. For binary black hole initial data, in particular, it is often assumed that there exists an approximate helical Killing vector that generates the binary's orbit. We show that 1 + log slices that are stationary with respect to such a helical Killing vector cannot be asymptotically flat, unless the spacetime possesses an additional axial Killing vector.

  1. Ballistic Puncture Self-Healing Polymeric Materials

    Science.gov (United States)

    Gordon, Keith L.; Siochi, Emilie J.; Yost, William T.; Bogert, Phil B.; Howell, Patricia A.; Cramer, K. Elliott; Burke, Eric R.

    2017-01-01

    Space exploration launch costs on the order of $10,000 per pound provide an incentive to seek ways to reduce structural mass while maintaining structural function to assure safety and reliability. Damage-tolerant structural systems provide a route to avoiding weight penalty while enhancing vehicle safety and reliability. Self-healing polymers capable of spontaneous puncture repair show promise to mitigate potentially catastrophic damage from events such as micrometeoroid penetration. Effective self-repair requires these materials to quickly heal following projectile penetration while retaining some structural function during the healing processes. Although there are materials known to possess this capability, they are typically not considered for structural applications. Current efforts use inexpensive experimental methods to inflict damage, after which analytical procedures are identified to verify that function is restored. Two candidate self-healing polymer materials for structural engineering systems are used to test these experimental methods.

  2. Successful use of nitrous oxide during lumbar punctures: A call for nitrous oxide in pediatric oncology clinics.

    Science.gov (United States)

    Livingston, Mylynda; Lawell, Miranda; McAllister, Nancy

    2017-11-01

    Numerous reports describe the successful use of nitrous oxide for analgesia in children undergoing painful procedures. Although shown to be safe, effective, and economical, nitrous oxide use is not yet common in pediatric oncology clinics and few reports detail its effectiveness for children undergoing repeated lumbar punctures. We developed a nitrous oxide clinic, and undertook a review of pediatric oncology lumbar puncture records for those patients receiving nitrous oxide in 2011. No major complications were noted. Minor complications were noted in 2% of the procedures. We offer guidelines for establishing such a clinic. © 2017 Wiley Periodicals, Inc.

  3. Laboratory Sampling Guide

    Science.gov (United States)

    2012-05-11

    environment, and by ingestion of foodstuffs that have incorporated C-14 by photosynthesis . Like tritium, C-14 is a very low energy beta emitter and is... bacterial growth and to minimize development of solids in the sample. • Properly identify each sample container with name, SSN, and collection start and...sampling in the same cardboard carton. The sample may be kept cool or frozen during collection to control odor and bacterial growth. • Once

  4. Endoscopic ultrasonography-guided rendezvous technique.

    Science.gov (United States)

    Tsuchiya, Takayoshi; Itoi, Takao; Sofuni, Atsushi; Tonozuka, Ryosuke; Mukai, Shuntaro

    2016-04-01

    Endoscopic retrograde cholangiopancreatography (ERCP) requires deep biliary cannulation. When deep biliary cannulation is failed, the endoscopic ultrasonography rendezvous technique (EUS-RV) is a useful salvage method. From the previous 15 articles that included 382 EUS-RV cases, the overall success rate of EUS-RV is 81 % with a complication rate of 10 %. In EUS-RV, the bile duct is punctured under EUS guidance and a guidewire is advanced into the duodenum via the papilla. The EUS scope is then switched to a duodenoscope and inserted into the bile duct over the guidewire exiting the papilla, or the guidewire is grasped with forceps and passed through the working channel; the catheter can then be inserted through the papilla over the wire. There are three puncture routes for EUS-RV: transgastric puncture of the intrahepatic bile duct (IHBD), transduodenal puncture of the extrahepatic bile duct (EHBD) via the proximal duodenum (D1), and transduodenal puncture of the EHBD via the second portion of the duodenum (D2). The puncture route for each patient should be selected based on the patient condition. GW selection for EUS-RV is critical, a hydrophilic GW is useful for this procedure. Although EUS-RV is now performed relatively routinely in a few high-volume centers, procedure standardization and the development of exclusive devices for EUS-RV are still underway. The development of exclusive devices for EUS-RV and prospective comparative studies with other salvage methods are needed to truly evaluate the procedure's usefulness and safety.

  5. Efficiency comparison of 3 kinds of arterial puncture closing devices

    International Nuclear Information System (INIS)

    Feng Xiaodi; Jin Xian; Chen Yueguang; Xiao Hongbing; Yu Qiang; Chen Chengjun; Zhang Dadong

    2007-01-01

    Objective: To evaluate the efficiencies of arterial puncture closing devices (APCDs) including Angioseal, Perclose and Boomerang in patients undergone coronary angiography or percutaneous vascular interventions. Methods: 1497 patients underwent cardiac catheterization procedures were divided into manual compression group(639 cases) and APCDs closure group (576 cases with Angioseal, 151 cases Perclose and 11.3 cases of Boomerang). The times of maneuver, hemorrhage complication and other rare complications were assessed, recorded and compared. Results: The times for maneuver of standard manual compression group, Angioseal group, Perclose group and Boomerang group were (21.4±2.7) h, (3.5±2.3) h, (3.7± 2.6) h and (3.9±2.8) h respectively. The APCDs could obviously reduce bed rest time in comparing to that of manual compression. The rates of failure of the operations were 2.7%, 1.4%, 8.6% and 3.5% (P =0.006, P<0.001); and the rates of hemorrhage were 9.2%, 5.8%, 12.6% and 8.0% respectively for each of the four mentioned groups (P=0.005). Except the failure operations, the incidence of hemorrhage complications among the groups showed no significant differences. Conclusion: Application of APCDs to close the puncture site can significantly reduce the bed rest time, but not the incidence of hemorrhage complications. (authors)

  6. Comparison of cutting and pencil-point spinal needle in spinal anesthesia regarding postdural puncture headache

    Science.gov (United States)

    Xu, Hong; Liu, Yang; Song, WenYe; Kan, ShunLi; Liu, FeiFei; Zhang, Di; Ning, GuangZhi; Feng, ShiQing

    2017-01-01

    Abstract Background: Postdural puncture headache (PDPH), mainly resulting from the loss of cerebral spinal fluid (CSF), is a well-known iatrogenic complication of spinal anesthesia and diagnostic lumbar puncture. Spinal needles have been modified to minimize complications. Modifiable risk factors of PDPH mainly included needle size and needle shape. However, whether the incidence of PDPH is significantly different between cutting-point and pencil-point needles was controversial. Then we did a meta-analysis to assess the incidence of PDPH of cutting spinal needle and pencil-point spinal needle. Methods: We included all randomly designed trials, assessing the clinical outcomes in patients given elective spinal anesthesia or diagnostic lumbar puncture with either cutting or pencil-point spinal needle as eligible studies. All selected studies and the risk of bias of them were assessed by 2 investigators. Clinical outcomes including success rates, frequency of PDPH, reported severe PDPH, and the use of epidural blood patch (EBP) were recorded as primary results. Results were evaluated using risk ratio (RR) with 95% confidence interval (CI) for dichotomous variables. Rev Man software (version 5.3) was used to analyze all appropriate data. Results: Twenty-five randomized controlled trials (RCTs) were included in our study. The analysis result revealed that pencil-point spinal needle would result in lower rate of PDPH (RR 2.50; 95% CI [1.96, 3.19]; P < 0.00001) and severe PDPH (RR 3.27; 95% CI [2.15, 4.96]; P < 0.00001). Furthermore, EBP was less used in pencil-point spine needle group (RR 3.69; 95% CI [1.96, 6.95]; P < 0.0001). Conclusions: Current evidences suggest that pencil-point spinal needle was significantly superior compared with cutting spinal needle regarding the frequency of PDPH, PDPH severity, and the use of EBP. In view of this, we recommend the use of pencil-point spinal needle in spinal anesthesia and lumbar puncture. PMID:28383416

  7. Technical compliance to standard guidelines for lumbar puncture and myelography: survey of academic neuroradiology attendings and fellows.

    Science.gov (United States)

    Zhang, Yi C; Chandler, Alexander J; Kagetsu, Nolan J

    2014-05-01

    To assess technical compliance among neuroradiology attendings and fellows to standard guidelines for lumbar puncture and myelography to minimize procedural complications such as iatrogenic meningitis and spinal headache. We surveyed academic neuroradiology attendings and fellows in the e-mail directory of the Association of Program Directors in Radiology. We queried use of face masks, use of noncutting needles, and dural puncture practices. All data were collected anonymously. A total of 110 survey responses were received: 75 from neuroradiology attendings and 34 from fellows, which represents a 14% response rate from a total of 239 fellows. Forty-seven out of 101 (47%) neuroradiologists do not always wear a face mask during myelograms, and 50 out of 105(48%) neuroradiologists do not always wear a face mask during lumbar punctures, placing patients at risk for iatrogenic meningitis. Ninety-six out of 106 neuroradiologists (91%) use the Quincke cutting needle by default, compared to only 17 out of 109 neuroradiologists (16%) who have ever used noncutting needles proven to reduce spinal headache. Duration of postprocedure bed rest does not influence incidence of spinal headache and may subject patients to unnecessary monitoring. Only 15 out of 109 (14%) neuroradiologists in our study do not prescribe bed rest. There was no statistically significant difference in practice between attendings and fellows. Iatrogenic meningitis and spinal headache are preventable complications of dural puncture that neuroradiologists can minimize by conforming to procedural guidelines. Wearing face masks and using noncutting spinal needles will reduce patient morbidity and lower hospitalization costs associated with procedural complications. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  8. Classical and quantum Liouville theory on the Riemann sphere with n>3 punctures (III)

    International Nuclear Information System (INIS)

    Shen Jianmin; Sheng Zhengmao; Wang Zhonghua

    1992-02-01

    We study the Classical and Quantum Liouville theory on the Riemann sphere with n>3 punctures. We get the quantum exchange algebra relations between the chiral components in the Liouville theory from our assumption on the principle of quantization. (author). 5 refs

  9. Clinical experience of quantex coordinate software for CT guided stereotactic surgery

    International Nuclear Information System (INIS)

    Yabashi, Toshitake; Ichikawa, Hideo; Yasuda, Eisuke; Tsuruta, Hatsuo; Ishikawa, Yoshihisa; Kimura, Tokuji; Kanamori, Isao

    1991-01-01

    Recently, Quantex Coordinate Software was newly developed for CT-guided stereotactic surgery. We have the opportunity of using this software in 6 cases with intracerebral hematoma for evacuation and 2 cases with brain tumor for needle biopsy by using CT-guided stereotactic surgery. The followings are the features with a little clinical experience. One of the biggest features is that this software can simulate the best expected route of the puncture needle from burr hole to target point before inserting. Also compared with CT 9000 series Software, it has many new functions for more advanced hardware as well as advance standard software. Two cases of intracerebral hematoma for evacuation and 1 case of a brain tumor for a biopsy were carried out using this software mainly as a simulation. In all cases, this software proved to be very useful. (author)

  10. Challenging the wisdom of puncture at the calyceal fornix in percutaneous nephrolithotripsy: feasibility and safety study with 137 patients operated via a non-calyceal percutaneous track.

    Science.gov (United States)

    Kyriazis, Iason; Kallidonis, Panagiotis; Vasilas, Marinos; Panagopoulos, Vasilios; Kamal, Wissam; Liatsikos, Evangelos

    2017-05-01

    To present our experience with a central, non-calyceal puncture protocol for percutaneous nephrolithotripsy (PCNL) in an attempt to challenge the opinion of worldwide adopted calyceal puncture as the less traumatic site of percutaneous entrance into the collecting system. During 2012, a total of 137 consecutive, unselected patients were subjected to PCNL in our department. Non-calyceal punctures were performed to all cases and followed by subsequent track dilations up to 30 Fr. Perioperative and postoperative data were prospectively collected and analyzed. Mean operative time (from skin puncture to nephrostomy tube placement) was 48 min. Patients with single, multiple and staghorn stones had primary stone-free rates of 89.2, 80.4 and 66.7 % after PCNL, respectively. The overall complication rate was 10.2 %, while bleeding complications were minimal. Only 4 patients (2.9 %) required blood transfusion. Five patients (3.6 %) had Clavien Grade IIIa complications requiring an intervention for their management and none Grade IV or V. Despite the absence of evidence that non-calyceal percutaneous tracts could be a risk factor for complications, the concept of calyceal puncture has been worldwide adopted by PCNL surgeons as the sole safe percutaneous entrance into the collective system. Based on our experience, other pathways than the worldwide recognized rule, calyceal puncture, are possible and probably not as dangerous as has been previously stated.

  11. In vivo serial sampling of epididymal sperm in mice.

    Science.gov (United States)

    Del Val, Gonzalo Moreno; Robledano, Patricia Muñoz

    2013-07-01

    This study was undertaken to refine the techniques of in vivo collection of sperm in the mouse. The principal objective was to offer a viable, safe and reliable method for serial collection of in vivo epididimary sperm through the direct puncture of the epididymis. Six C57Bl/6J males were subjected to the whole experiment. First we obtain a sperm sample of the right epididymis, and perform a vasectomy on the left side. This sample was used in an in vitro fertilization (IVF) experiment while the males were individually housed for 10 days to let them recover from the surgery, and then their fertility was tested with natural matings until we obtained a litter of each one. After that, the animals were subjected another time to the same process (sampling, recover and natural mating). The results of these experiments were a fertilization average value of 56.7%, and that all the males had a litter in the first month after the natural matings. This study documented the feasibility of the epididimary puncture technique to in vivo serial sampling of sperm in the mouse.

  12. Comparison the effect of lidocaine gel and inhalation of lavender aromatherapy on pain score of arteriovenous fistula puncture in hemodialysis patients

    OpenAIRE

    Abbaszadeh

    2015-01-01

    Introduction: patients undergoing hemodialysis repetitively experience pain and anxiety related to arterivenous fistula (AVF) punctures. Using of appropriate methods of pain relief in these patients is very important. The purpose of this study was to compare the effect of lidocaine gel and inhalation of lavender aromatherapy on pain intensity of arterivenous fistula puncture in hemodialysis patients. Methods: In this before and after clinical trial study, 40 hemodialysis patients were sele...

  13. Guide to sampling airborne radioactive materials in nuclear facilities

    International Nuclear Information System (INIS)

    Glissmeyer, J.A.

    1995-01-01

    The ANSI N13.1-1969 Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities is currently being revised. The revision is being drafted by a working group under the auspices of the Health Physics Society Standards Committee. The main differences between the original standard and the proposed revision are a narrowed scope, a greater emphasis on the design process, and the verification of meeting performance criteria. Compliance with the revised standard will present new challenges, especially in the area of performance validation. The progress made in the revision and key portions of the standard are discussed. The DOE has recently petitioned EPA for alternate approaches to complying with air-sampling regulations. Dealing with compliance issues until the revised standard is adopted will be a challenge for both designers and regulators. The objective of this paper is to briefly describe the content of the proposed revision in order to point out significant differences from the old standard and to describe the new challenges that the proposed revision will present

  14. Guide to sampling airborne radioactive materials in nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, J.A. [Pacific Northwest Laboratory, Richland, WA (United States)

    1995-02-01

    The ANSI N13.1-1969 Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities is currently being revised. The revision is being drafted by a working group under the auspices of the Health Physics Society Standards Committee. The main differences between the original standard and the proposed revision are a narrowed scope, a greater emphasis on the design process, and the verification of meeting performance criteria. Compliance with the revised standard will present new challenges, especially in the area of performance validation. The progress made in the revision and key portions of the standard are discussed. The DOE has recently petitioned EPA for alternate approaches to complying with air-sampling regulations. Dealing with compliance issues until the revised standard is adopted will be a challenge for both designers and regulators. The objective of this paper is to briefly describe the content of the proposed revision in order to point out significant differences from the old standard and to describe the new challenges that the proposed revision will present.

  15. A guide to the use of distance sampling to estimate abundance of Karner blue butterflies

    Science.gov (United States)

    Grundel, Ralph

    2015-01-01

    This guide is intended to describe the use of distance sampling as a method for evaluating the abundance of Karner blue butterflies at a location. Other methods for evaluating abundance exist, including mark-release-recapture and index counts derived from Pollard-Yates surveys, for example. Although this guide is not intended to be a detailed comparison of the pros and cons of each type of method, there are important preliminary considerations to think about before selecting any method for evaluating the abundance of Karner blue butterflies.

  16. Comparison of two navigation systems for CT-guided interventions under special consideration of the ergonomic properties of the used systems; Vergleich zweier Navigationshilfen fuer CT-gesteuerte Interventionen unter besonderer Beruecksichtigung der Nutzungseigenschaften der verwendeten Systeme

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, T. [Inst. fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Jena (Germany); Roettger, S. [Klinik fuer Nuklearmedizin, Medizinische Hochschule Hannover (Germany); Bahner-Heyne, E.J.; Kluge, G. [Inst. fuer Psychologie und Arbeitswissenschaft, FG Arbeits-, Ingenieur- und Organisationspsychologie, TU Berlin (Germany)

    2009-06-15

    Purpose: investigation of the influence of CT-based navigation systems on the success of an intervention, assessment of the advantages and disadvantages of the utilized systems, and evaluation of the ergonomic system properties. Materials and method: a simple guiding system PatPos Invent trademark and the computer-based navigation system PinPoint trademark were employed on two CT systems. In order to investigate the influence of the navigation aids on the success of the interventions, 96 prospective, randomized, and standardized punctures were performed on a specifically developed, rigid phantom. 16 examiners punctured 6 targets with 3 degrees of difficulty with the navigation aids. Results: irrespective of the experience of the examiner, both navigation systems guided the target with an equal degree of certainty. PinPoint significantly reduced the length of the examination time (12 - 25 min) as compared to PatPos Invent (20 - 40 min). The expectation conformity and comprehensibility of PatPos Invent were assessed significantly more positively than PinPoint with regard to the general handling of the system. In contrast, the assessment of the usability during preoperative setup favored PinPoint. The type of navigation system has no influence on the precision of the implementation of a puncture procedure. (orig.)

  17. Ultrasonography-guided peripheral intravenous access versus traditional approaches in patients with difficult intravenous access.

    Science.gov (United States)

    Costantino, Thomas G; Parikh, Aman K; Satz, Wayne A; Fojtik, John P

    2005-11-01

    We assess the success rate of emergency physicians in placing peripheral intravenous catheters in difficult-access patients who were unsuccessfully cannulated by emergency nurses. A technique using real-time ultrasonographic guidance by 2 physicians was compared with traditional approaches using palpation and landmark guidance. This was a prospective, systematically allocated study of all patients requiring intravenous access who presented to 2 university hospitals between October 2003 and March 2004. Inclusion criterion was the inability of any available nurse to obtain intravenous access after at least 3 attempts on a subgroup of patients who had a history of difficult intravenous access because of obesity, history of intravenous drug abuse, or chronic medical problems. Exclusion criterion was the need for central venous access. Patients presenting on odd days were allocated to the ultrasonographic-guided group, and those presenting on even days were allocated to the traditional-approach group. Endpoints were successful cannulation, number of sticks, time, and patient satisfaction. Sixty patients were enrolled, 39 on odd days and 21 on even days. Success rate was greater for the ultrasonographic group (97%) versus control (33%), difference in proportions of 64% (95% confidence interval [CI] 39% to 71%). The ultrasonographic group required less overall time (13 minutes versus 30 minutes, for a difference of 17 [95% CI 0.8 to 25.6]), less time to successful cannulation from first percutaneous puncture (4 minutes versus 15 minutes, for a difference of 11 [95% CI 8.2 to 19.4]), and fewer percutaneous punctures (1.7 versus 3.7, for a difference of 2.0 [95% CI 1.27 to 2.82]) and had greater patient satisfaction (8.7 versus 5.7, for a difference of 3.0 [95% CI 1.82 to 4.29]) than the traditional landmark approach. Ultrasonographic-guided peripheral intravenous access is more successful than traditional "blind" techniques, requires less time, decreases the number of

  18. Usefulness of CT-guided trans-bronchial needle aspiration biopsy for mediastinal lymph nodes

    International Nuclear Information System (INIS)

    Cui Bing; Rong Fu

    2001-01-01

    Objective: To determine the nature of enlarged mediastinal lymph nodes, the study of CT-guided trans-bronchial needle aspiration biopsy (CT-TBNA) was conducted. Methods: According to classification and locating standard of mediastinal lymph nodes, CT-TBNA was performed in 158 mediastinal lymph nodes of 73 patients, including 54 primary lung cancer with enlarged mediastinal lymph nodes, 5 malignant lymphoma, 3 mediastinal abscess and 11 mediastinal inflammatory adenopathy. Results: CT confirmed that the needles were inside all 158 lymph nodes. Adequate aspirates for histologic and/or cytologic diagnosis were obtained in 136 of 158(86%) lymph node biopsies. No serious complications occurred. Conclusion: Locating standard of CT-guided TBNA was reliable. Puncture was safe and cost-effective. CT-TBNA was important for ascertaining the nature of mediastinal adenopathy and staging of neoplasms

  19. Technical measurement of small fission gas inventory in fuel rod with laser puncturing system

    International Nuclear Information System (INIS)

    Kim, Hee Moon; Kim, Sung Ryul; Lee, Byoung Oon; Yang, Yong Sik; Baek, Sang Ryul; Song, Ung Sup

    2012-01-01

    The fission gas release cause degradation of fuel rod. It influences fuel temperature and internal pressure due to low thermal conductivity. Therefore, fission gas released to internal void of fuel rod must be measured with burnup. To measure amount of fission gas, fuel rod must be punctured by a steel needle in a closed chamber. Ideal gas law(PV=nRT) is applied to obtain atomic concentration(mole). Steel needle type is good for large amount of fission gas such as commercial spent fuel rod. But, some cases with small fuel rig in research reactor for R/D program are not available to use needle type because of large chamber volume. The laser puncturing technique was developed to solve measurement of small amount of fission gas. This system was very rare equipment in other countries. Fine pressure gage and strong vacuum system were installed, and the chamber volume was reduced at least. Fiber laser was used for easy operation

  20. Clinical observation of Ahmed glaucoma valve implantation for refractory glaucoma by directly puncturing the sclerotic tunnel

    Directory of Open Access Journals (Sweden)

    Zhi-Ke Xu

    2015-02-01

    Full Text Available AIM: To observe the clinic effects and complication of Ahmed glaucoma valve(AGVimplantation in refractory glaucoma by using the 23G syringe needle direct puncture the sclerotic tunnel.METHODS: Forty-four cases(44 eyesof refractory glaucoma underwent AGV implantation by useing the 23G syringe needle direct puncture the sclerotic tunnel. The intraocular pressure(IOP, visual acuity, and complication of post-operation were contrasted with those of pre-operation. RESULTS:The success rate was 84.1%, the mean preoperative IOP in research group was 52.1±10.1mmHg, and the last follow up mean IOP was 15.6±6.9mmHg. Compared with the preoperative visual acuity, 11 eyes increased, 27 eyes had no changes and 6 eyes decreased. The main post-operative complications included shallow anterior chamber(4 eyes, choroidal detachment(3 eyes, drainage tube shift(1 eye, hyphema(6 eyes, drainage tube blockage(1 eye, expulsive choroidal hemorrhage(1 eye, and fiber wrap of drainage tray(5 eyes.CONCLUSION: AGV implantation by direct puncture the sclerotic tunnel is feasible and easy. It avoids of making sclerotic petal and the xenogenic sclera transplanting, simplified the operation technique, prevent the leakage of around tube. The shallow anterior chamber rate is lower. It is an effective procedure for refractory glaucoma.

  1. CT-guided percutaneous ethanol nerve block therapy of celiac plexus embedded in metastatic lymph nodes for the treatment of intractable carcinomatous abdominal pain

    International Nuclear Information System (INIS)

    Xi Qian; Wang Peijun; Shang Mingyi; Ma Jun; Lu Ying; Huang Zongliang; Tang Junjun; Gao Xiaolong

    2010-01-01

    Objective: To evaluate CT-guided percutaneous ethanol nerve block therapy of celiac plexus embedded in metastatic lymph nodes in treating intractable carcinomatous abdominal pain. Methods: A total of 104 patients with late stage cancers were enrolled in this study. All patients suffered from serious carcinomatous pain at upper abdomen and their retroperitoneal lymph nodes were extensively enlarged and fused, together with the involved celiac plexus, into a hard crumb. As the patients failed to respond to narcotic analgesics CT-guided ethanol nerve block therapy of celiac plexus was carried out by pushing the puncture needle through the fused lymphatic mass to celiac plexus site. The analgesic effects and complications were observed and the therapeutic results were evaluated. Results: The analgesic effective rate of ethanol nerve block therapy immediately after the procedure was 100%, and at 2 weeks, 1, 2, 3 and 4 months after the treatment it was 100%, 100%, 98.0%, 96.9% and 92.6%, respectively. No serious complications occurred during perioperative period. The living quality was markedly improved in all patients. Conclusion: For the treatment of intractable carcinomatous abdominal pain in patients with their celiac plexus being embedded in mass-like metastatic retroperitoneal lymph nodes CT-guided percutaneous ethanol nerve block therapy by pushing the puncture needle through the fused lymphatic mass to celiac plexus site is of great clinical value in relieving carcinomatous abdominal pain. (authors)

  2. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline - Updated January 2017.

    Science.gov (United States)

    Dumonceau, Jean-Marc; Deprez, Pierre H; Jenssen, Christian; Iglesias-Garcia, Julio; Larghi, Alberto; Vanbiervliet, Geoffroy; Aithal, Guruprasad P; Arcidiacono, Paolo G; Bastos, Pedro; Carrara, Silvia; Czakó, László; Fernández-Esparrach, Gloria; Fockens, Paul; Ginès, Àngels; Havre, Roald F; Hassan, Cesare; Vilmann, Peter; van Hooft, Jeanin E; Polkowski, Marcin

    2017-07-01

    For pancreatic solid lesions, ESGE recommends performing endoscopic ultrasound (EUS)-guided sampling as first-line procedure when a pathological diagnosis is required. Alternatively, percutaneous sampling may be considered in metastatic disease.Strong recommendation, moderate quality evidence.In the case of negative or inconclusive results and a high degree of suspicion of malignant disease, ESGE suggests re-evaluating the pathology slides, repeating EUS-guided sampling, or surgery.Weak recommendation, low quality evidence.In patients with chronic pancreatitis associated with a pancreatic mass, EUS-guided sampling results that do not confirm cancer should be interpreted with caution.Strong recommendation, low quality evidence.For pancreatic cystic lesions (PCLs), ESGE recommends EUS-guided sampling for biochemical analyses plus cytopathological examination if a precise diagnosis may change patient management, except for lesions ≤ 10 mm in diameter with no high risk stigmata. If the volume of PCL aspirate is small, it is recommended that carcinoembryonic antigen (CEA) level determination be done as the first analysis.Strong recommendation, low quality evidence.For esophageal cancer, ESGE suggests performing EUS-guided sampling for the assessment of regional lymph nodes (LNs) in T1 (and, depending on local treatment policy, T2) adenocarcinoma and of lesions suspicious for metastasis such as distant LNs, left liver lobe lesions, and suspected peritoneal carcinomatosis.Weak recommendation, low quality evidence.For lymphadenopathy of unknown origin, ESGE recommends performing EUS-guided (or alternatively endobronchial ultrasound [EBUS]-guided) sampling if the pathological result is likely to affect patient management and no superficial lymphadenopathy is easily accessible.Strong recommendation, moderate quality evidence.In the case of solid liver masses suspicious for metastasis, ESGE suggests performing EUS-guided sampling if the pathological result is likely

  3. 40 CFR 63.6000 - How do I conduct tests and procedures for puncture sealant application affected sources?

    Science.gov (United States)

    2010-07-01

    ... Tire Manufacturing Testing and Initial Compliance Requirements for Puncture Sealant Application... balances to demonstrate compliance, if the storage of materials, exhaust, or the wastewater from more than...

  4. Assessment of Residents Readiness to Perform Lumbar Puncture

    DEFF Research Database (Denmark)

    Henriksen, Mikael Johannes Vuokko; Wienecke, Troels; Thagesen, Helle

    2017-01-01

    and 18 novices performing the procedure in a simulated, ward-like setting with a standardized patient. Procedural performance was assessed by three content experts. We used generalizability theory to explore reliability. The discriminative ability of the tool was explored by comparing performance scores......Background: Lumbar puncture is a common procedure in many specialties. The procedure serves to diagnose life-threatening conditions, often requiring rapid performance. However, junior doctors possess uncertainties regarding performing the procedure and frequently perform below expectations. Hence...... between the two groups. The contrasting groups method was used to set a pass/fail standard and the consequences of this was explored. Key results: The interviews identified that in addition to the technical aspects of the procedure, non-technical elements involving planning and conducting the procedure...

  5. MR-guided perineural injection of the ganglion impar: technical considerations and feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Marker, David R.; Carrino, John A.; Fritz, Jan [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Musculoskeletal Radiology, Baltimore, MD (United States); U-Thainual, Paweena [Queen' s University, Department of Mechanical and Materials Engineering, Kingston, ON (Canada); Ungi, Tamas; Fichtinger, Gabor [Queen' s University, School of Computing, Kingston, ON (Canada); Flammang, Aaron J. [Siemens Corporate Research, Center for Applied Medical Imaging, Baltimore, MD (United States); Iordachita, Iulian I. [Johns Hopkins University, Department of Mechanical Engineering and Laboratory for Computational Sensing and Robotics, Baltimore, MD (United States)

    2016-05-15

    Perineural ganglion impar injections are used in the management of pelvic pain syndromes; however, there is no consensus regarding the optimal image guidance. Magnetic resonance imaging (MRI) provides high soft tissue contrast and the potential to directly visualize and target the ganglion. The purpose of this study was to assess the feasibility of MR-guided percutaneous perineural ganglion impar injections. Six MR-guided ganglion impar injections were performed in six human cadavers. Procedures were performed with a clinical 1.5-Tesla MRI system through a far lateral transgluteus approach. Ganglion impar visibility, distance from the sacrococcygeal joint, number of intermittent MRI control steps required to place the needle, target error between the intended and final needle tip location, inadvertent punctures of non-targeted vulnerable structures, injectant distribution, and procedure time were determined. The ganglion impar was seen on MRI in 4/6 (66 %) of cases and located 0.8 mm cephalad to 16.3 mm caudad (average 1.2 mm caudad) to the midpoint of the sacrococcygeal joint. Needle placement required an average of three MRI control steps (range, 2-6). The average target error was 2.2 ± 2.1 mm. In 6/6 cases (100 %), there was appropriate periganglionic distribution and filling of the presacrococcygeal space. No punctures of non-targeted structures occurred. The median procedure time was 20 min (range, 12-29 min). Interventional MRI can visualize and directly target the ganglion impar for accurate needle placement and successful periganglionic injection with the additional benefit of no ionizing radiation exposure to patient and staff. Our results support clinical evaluation. (orig.)

  6. Eggshell strength of an obligate brood parasite: a test of the puncture resistance hypothesis

    Czech Academy of Sciences Publication Activity Database

    Antonov, A.; Stokke, B. G.; Moksnes, A.; Kleven, O.; Honza, Marcel; Roskaft, E.

    2006-01-01

    Roč. 60, č. 1 (2006), s. 11-18 ISSN 0340-5443 Grant - others:Research Council of Norway(NO) 151641/432 Institutional research plan: CEZ:AV0Z60930519 Keywords : brood parasitism * eggshell thickness * puncture resistance * Acrocephalus * cuckoo Subject RIV: EG - Zoology Impact factor: 2.316, year: 2006

  7. A new image navigation system for MR-guided cryosurgery

    International Nuclear Information System (INIS)

    Mogami, Takuji; Dohi, Michiko; Harada, Junta

    2002-01-01

    The purpose of this study was to evaluate the feasibility of Interactive Scan Control (ISC), a new MR image navigation system, during percutaneous puncture in cryosurgery. With the ISC system in place, percutaneous MR-guided cryosurgery was performed in 26 cases, with the ISC system being used in 11 cases (five renal tumors, three uterine fibroids and three metastatic liver tumors). The ISC system comprised infrared cameras and an MR-compatible optical tracking tool that was directly connected to a cryoprobe. Tumor sizes ranged from 1.2 cm (metastatic liver tumor) to 9.0 cm (uterine fibroid), for a mean size of 3.9 cm. With ISC, one to three cryoprobes with a diameter of 2 mm or 3 mm were advanced into the tumors with the guidance of an MR fluoroscopic image. Two freeze-thaw cycles were used for cryosurgery. During the cryosurgery, the formation of iceballs was monitored on MR images. Follow-up dynamic CT or MRI as well as physical examinations were conducted after two weeks and six weeks. Placement of probes was successfully performed under the control of the ISC system. During cryosurgery, engulfment of the tumors by iceballs was carefully monitored by MRI. Necrosis of the cryoablated area was confirmed in all renal tumors by follow-up dynamic CT. The size regression of the uterine fibroids was observed through follow-up MRI. Two of the three cases of metastatic liver tumor were ablated completely. Additional therapy for a residual tumor was performed on one patient with a metastatic liver tumor. A small amount of pneumothorax was the only complication found in a patient with a metastatic liver tumor. MR-guided cryosurgery with this new navigation system was feasible with low morbidity and allowed for safe and accurate puncture with a cryoprobe. (author)

  8. Retrospective 5-year analysis of MR-guided biopsies in a low-field MR system

    International Nuclear Information System (INIS)

    Zangos, Stephan; Mueller, C.; Mayer, F.; Naguib, N.N.; Nour-Eldin, N.E.A.; Herzog, C.; Hammerstingl, R.M.; Thalhammer, A.; Mack, M.G.; Vogl, T.J.; Eichler, K.; Hansmann, M.L.

    2009-01-01

    Purpose: The purpose of this study was to evaluate the safety and clinical value of MR-guided biopsies in an open 0.2 T low-field system. Materials and methods: A total of 322 patients with suspicious lesions of different body regions were biopsied in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted Flash sequences (TR/TE = 100/9; 70 ). The lesions were repeatedly biopsied using the coaxial technique with a 15-gauge (diameter 2 mm) puncture needle. Complications and biopsy findings were analyzed retrospectively. Results: In all cases the biopsy procedures were successfully performed with MR guidance. In 298 patients diagnosis was able to be confirmed on the basis of the probes. The clinical follow-up showed that in 24 patients the lesions were missed by MR-guided biopsy. From this a sensitivity of 86%, a specificity of 87% and an accuracy of 93% were calculated. In two patients major complications were observed (morbidity rate 0.6%). Conclusion: MR-guided biopsy can be performed safely and precisely in a low-field MR system and are a supplement to US or CT-guided biopsies. (orig.)

  9. Comparison of the efficacy of epidural autologous blood patch in the treatment of spontaneous intracranial hypotension and post-dural puncture headache

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sung Hyun; Lee, Jon Woo; Lee, Geun Young; Lee, Eu Gene; Kang, Heung Sik [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2014-04-15

    To evaluate and compare the effectiveness of fluoroscopy-guided epidural blood patch (EBP) in patients with post-dural puncture headache (PDPH) and spontaneous intracranial hypotension (SIH). Between August 2012 and September 2013, 16 patients (12 with PDPH, 4 with SIH; 5 males, 11 females; age range 19-58 years, mean age 32.8 years) who underwent EBP in the Department of Radiology were included in this study. Pain relief within three days after EBP was evaluated based on medical record and classified on a 3-level scale: complete relief; incomplete relief; and failure. Recurrence is defined as aggravated postural headache after three days. We evaluated and compared treatment outcome between PDPH and SIH, using Fisher's exact test (considered as significant when p < 0.05). In 12 PDPH patients, the EBP provided complete relief in 5 patients (41.7%), and incomplete relief in 7 patients (58.3%). In 4 SIH patients, the EBP provided complete relief in 1 patient (25%), and incomplete relief in 3 patients (75%). There was no significant difference (p = 0.511) of pain relief rate between PDPH and SIH. There was recurrence in 5 patients with PDPH and 1 patient with SIH. Five PDPH patients were retreated by EBP with incomplete relief. Fluoroscopy-guided EBP provides effective treatment of postural headache for both SIH and PDPH patients.

  10. Comparison of the efficacy of epidural autologous blood patch in the treatment of spontaneous intracranial hypotension and post-dural puncture headache

    International Nuclear Information System (INIS)

    Yoon, Sung Hyun; Lee, Jon Woo; Lee, Geun Young; Lee, Eu Gene; Kang, Heung Sik

    2014-01-01

    To evaluate and compare the effectiveness of fluoroscopy-guided epidural blood patch (EBP) in patients with post-dural puncture headache (PDPH) and spontaneous intracranial hypotension (SIH). Between August 2012 and September 2013, 16 patients (12 with PDPH, 4 with SIH; 5 males, 11 females; age range 19-58 years, mean age 32.8 years) who underwent EBP in the Department of Radiology were included in this study. Pain relief within three days after EBP was evaluated based on medical record and classified on a 3-level scale: complete relief; incomplete relief; and failure. Recurrence is defined as aggravated postural headache after three days. We evaluated and compared treatment outcome between PDPH and SIH, using Fisher's exact test (considered as significant when p < 0.05). In 12 PDPH patients, the EBP provided complete relief in 5 patients (41.7%), and incomplete relief in 7 patients (58.3%). In 4 SIH patients, the EBP provided complete relief in 1 patient (25%), and incomplete relief in 3 patients (75%). There was no significant difference (p = 0.511) of pain relief rate between PDPH and SIH. There was recurrence in 5 patients with PDPH and 1 patient with SIH. Five PDPH patients were retreated by EBP with incomplete relief. Fluoroscopy-guided EBP provides effective treatment of postural headache for both SIH and PDPH patients.

  11. Construction of Rate-Compatible LDPC Codes Utilizing Information Shortening and Parity Puncturing

    Directory of Open Access Journals (Sweden)

    Jones Christopher R

    2005-01-01

    Full Text Available This paper proposes a method for constructing rate-compatible low-density parity-check (LDPC codes. The construction considers the problem of optimizing a family of rate-compatible degree distributions as well as the placement of bipartite graph edges. A hybrid approach that combines information shortening and parity puncturing is proposed. Local graph conditioning techniques for the suppression of error floors are also included in the construction methodology.

  12. Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures

    International Nuclear Information System (INIS)

    Sommer, C.M.; Huber, J.; Radeleff, B.A.; Hosch, W.; Stampfl, U.; Loenard, B.M.; Hallscheidt, P.; Haferkamp, A.; Kauczor, H.U.; Richter, G.M.

    2011-01-01

    Aim: To report our experience of combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures. Patients and methods: Eighteen patients (23 kidneys) with non-obstructive uropathy due to urine leaks underwent combined CT- and fluoroscopy-guided nephrostomy. All procedures were indicated as second-line interventions after failed ultrasound-guided nephrostomy. Thirteen males and five females with an age of 62.3 ± 8.7 (40–84) years were treated. Urine leaks developed in majority after open surgery, e.g. postoperative insufficiency of ureteroneocystostomy (5 kidneys). The main reasons for failed ultrasound-guided nephrostomy included anatomic obstacles in the puncture tract (7 kidneys), and inability to identify pelvic structures (7 kidneys). CT-guided guidewire placement into the collecting system was followed by fluoroscopy-guided nephrostomy tube positioning. Procedural success rate, major and minor complication rates, CT-views and needle passes, duration of the procedure and radiation dose were analyzed. Results: Procedural success was 91%. Major and minor complication rates were 9% (one septic shock and one perirenal abscess) and 9% (one perirenal haematoma and one urinoma), respectively. 30-day mortality rate was 6%. Number of CT-views and needle passes were 9.3 ± 6.1 and 3.6 ± 2.6, respectively. Duration of the complete procedure was 87 ± 32 min. Dose-length product and dose-area product were 1.8 ± 1.4 Gy cm and 3.9 ± 4.3 Gy cm 2 , respectively. Conclusions: Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures was feasible with high technical success and a tolerable complication rate.

  13. Significance of preoperative planning software for puncture and channel establishment in percutaneous endoscopic lumbar DISCECTOMY: A study of 40 cases.

    Science.gov (United States)

    Hu, Zhouyang; Li, Xinhua; Cui, Jian; He, Xiaobo; Li, Cong; Han, Yingchao; Pan, Jie; Yang, Mingjie; Tan, Jun; Li, Lijun

    2017-05-01

    Preoperative planning software has been widely used in many other minimally invasive surgeries, but there is a lack of information describing the clinical benefits of existing software applied in percutaneous endoscopic lumbar discectomy (PELD). This study aimed to compare the clinical efficacy of preoperative planning software in puncture and channel establishment of PELD with routine methods in treating lumbar disc herniation (LDH). From June 2016 to October 2016, 40 patients who had single L4/5 or L5/S1 disc herniation were divided into two groups. Group A adopted planning software for preoperative puncture simulation while Group B took routine cases discussion for making puncture plans. The channel establishment time, operative time, fluoroscopic times and complications were compared between the two groups. The surgical efficacy was evaluated according to the Visual Analogue Scale (VAS), Oswestry Disability Index (ODI) and modified Macnab's criteria. The mean channel establishment time was 25.1 ± 4.2 min and 34.6 ± 5.4 min in Group A and B, respectively (P  0.05). The findings of modified Macnab's criteria at each follow-up also showed no significant differences (P > 0.05). The application of preoperative planning software in puncture and cannula insertion planning in PELD was easy and reliable, and could reduce the channel establishment time, operative time and fluoroscopic times of PELD significantly. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  14. Determination of Critical Conditions for Puncturing Almonds Using Coupled Response Surface Methodology and Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Mahmood Mahmoodi-Eshkaftaki

    2013-01-01

    Full Text Available In this study, the effect of seed moisture content, probe diameter and loading velocity (puncture conditions on some mechanical properties of almond kernel and peeled almond kernel is considered to model a relationship between the puncture conditions and rupture energy. Furthermore, distribution of the mechanical properties is determined. The main objective is to determine the critical values of mechanical properties significant for peeling machines. The response surface methodology was used to find the relationship between the input parameters and the output responses, and the fitness function was applied to measure the optimal values using the genetic algorithm. Two-parameter Weibull function was used to describe the distribution of mechanical properties. Based on the Weibull parameter values, i.e. shape parameter (β and scale parameter (η calculated for each property, the mechanical distribution variations were completely described and it was confirmed that the mechanical properties are rule governed, which makes the Weibull function suitable for estimating their distributions. The energy model estimated using response surface methodology shows that the mechanical properties relate exponentially to the moisture, and polynomially to the loading velocity and probe diameter, which enabled successful estimation of the rupture energy (R²=0.94. The genetic algorithm calculated the critical values of seed moisture, probe diameter, and loading velocity to be 18.11 % on dry mass basis, 0.79 mm, and 0.15 mm/min, respectively, and optimum rupture energy of 1.97·10-³ J. These conditions were used for comparison with new samples, where the rupture energy was experimentally measured to be 2.68 and 2.21·10-³ J for kernel and peeled kernel, respectively, which was nearly in agreement with our model results.

  15. Posture and lumbar puncture headache: a controlled trial in 50 patients.

    OpenAIRE

    Handler, C E; Smith, F R; Perkin, G D; Rose, F C

    1982-01-01

    A prospective single blind trial in 50 patients was performed to investigate the effect of posture on post lumbar puncture headache (LPH). A difference between the frequency of headache at five hours between the two groups (prone for four hours, versus 30 degrees head down tilt for 30 minutes followed by supine posture for 3 1/2 hours) did not reach significance. These findings do not support the suggestion that a prone posture, by possibly reducing cerebrospinal fluid (CSF) leakage, signific...

  16. Percutaneous evacuation of diffuse pulmonary interstitial emphysema by lung puncture in a baby with extremely low birth weight: a case report

    Directory of Open Access Journals (Sweden)

    Watanabe Masahiro

    2012-09-01

    Full Text Available Abstract Introduction Pulmonary interstitial emphysema is a serious complication of mechanical ventilation and can become life-threatening if progression occurs. Therapeutic lung puncture is a treatment option for severe pulmonary interstitial emphysema but has a limited use in babies with extremely low birth weight. We present a case of pulmonary interstitial emphysema in a Japanese baby (1-day-old boy with extremely low birth weight. The emphysema was successfully decompressed by therapeutic lung puncture performed with a trocar catheter. Case presentation The baby was born with a weight of 420g, which, to the best of our knowledge, is the lowest reported birth weight among babies with pulmonary interstitial emphysema. A chest X-ray on postnatal day 2 revealed pulmonary interstitial emphysema, which gradually progressed to diffuse pseudocystic changes. His condition became life-threatening despite the use of high-frequency oscillatory ventilation and lateral decubitus positioning. We evacuated the pulmonary interstitial emphysema by lung puncture with a trocar catheter to avoid respiratory and cardiovascular collapse. This resulted in adequate evacuation of the emphysema and a dramatic improvement in his clinical condition. Conclusions Therapeutic lung puncture performed with a trocar catheter is beneficial in babies with extremely low birth weight and diffuse pulmonary interstitial emphysema. This treatment option may be broadly applicable, especially in an emergency situation.

  17. Effectiveness of autologous epidural blood patch to relieve post dural puncture headache

    International Nuclear Information System (INIS)

    Iqbal, L.A.A.; Naqvi, E.H.

    2013-01-01

    Background: Post-dural puncture headache (PDPH) is a common problem in anaesthesia practice especially in obstetric anaesthesia. Autologous epidural blood patch (AEBP) is the main stay of treatment of PDPH when it is not relieved with conservative management. Objective: To describe the efficacy of AEBP in treatment of PDPH. Study Design: Prospective descriptive study. Setting and Duration: The study was conducted at departments of Anaesthesia and Intensive Care, Military Hospital, Rawalpindi and Combined Military Hospital, Malir, from July 2008 to July 2011. Methodology: All patients who received AEBP during study period secondary to PDPH were included. Up to 20 ml of autologous blood was injected in epidural space. Effectiveness of AEBP was judged by relief of symptom; any complications associated with AEBP i.e. backache and paresthesia were also noted. Data was interpreted as mean and percentages. Results: A total of 30 AEBP were performed during the study period in predominantly female patients (n=27) with mean age of 27.8 years. AEBP was performed after a mean 3.83 days of lumbar puncture. Complete relief was observed in 29 (96%) patients; one patient required a second patch. During the follow-up, 7 (23%) patients complained of backache and 2(6%) of paresthesias. conclusion: AEBP is an effective way of providing relief from PDPH. (author)

  18. CT-guided biopsies and drainage; CT-gesteuerte Punktionen und Drainagen

    Energy Technology Data Exchange (ETDEWEB)

    Scheppers, I.; Wollschlaeger, D. [Staedtisches Klinikum Karlsruhe gGmbH, Zentralinstitut fuer Bildgebende Diagnostik, Karlsruhe (Germany)

    2011-11-15

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [German] Infolge der Durchfuehrung von bildgesteuerten Biopsien solider Raumforderungen und Punktionen mit Drainageeinlage bei liquiden Prozessen ist die Zahl chirurgischer Exzisionsbiopsien und Abszesssanierungen zurueckgegangen. Diese Eingriffe werden in nahezu allen Organgebieten durchgefuehrt. Neben den Aspirationsbiopsien werden haeufig Schneid- oder Stanzbiopsien durchgefuehrt. Nach histologischer und immunhistologischer Untersuchung der hierbei gewonnenen Proben in der Pathologie kann fruehzeitig die nachfolgende Therapie geplant werden. Der vorliegende Beitrag soll einen allgemeinen Ueberblick ueber Methoden, Materialien, Indikationen und Kontraindikationen geben. Die ultraschallgesteuerten Biopsien sowie die Vakuumsaugbiopsien im Rahmen des Mammographiescreenings werden bewusst nicht besprochen. (orig.)

  19. Posterior reversible encephalopathy syndrome following an inadvertent dural puncture during an emergency laparotomy for ischemic colitis – a case report

    Directory of Open Access Journals (Sweden)

    Shah R

    2014-01-01

    Full Text Available Reena Shah, Agnieszka Kubisz-Pudelko, Jeremy Reid Yeovil District Hospital, Yeovil, UK Abstract: Posterior reversible encephalopathy syndrome (PRES is a clinico-neuroradiological syndrome characterized by various symptoms of neurological disease. It has commonly been reported in association with acute hypertension, pre-eclampsia, eclampsia, sepsis, and exposure to immunosuppressants. Here, we report on a normotensive woman who developed a severe frontal headache, visual disturbances, and hypertension 3 days after undergoing an emergency laparotomy for ischemic colitis during which she suffered an inadvertent dural puncture. Neuro-imaging revealed features consistent with PRES. The patient went on to make a good recovery, being discharged 21 days postoperatively, with only minor visual disturbances and memory problems. This case highlights the importance of awareness of PRES to all specialties. On reviewing the literature, we feel that PRES may be a potential differential diagnosis to post-procedural neurological symptoms in those patients undergoing routine procedures such as spinal anesthetics or lumbar punctures. Keywords: PRES, neurological disease, lumbar puncture, spinal anesthetic

  20. COMPARATIVE STUDY OF ENDOMETRIAL SAMPLING USING PIPELLE WITH HYSTEROSCOPIC-GUIDED BIOPSY

    Directory of Open Access Journals (Sweden)

    Nalina S

    2017-07-01

    Full Text Available BACKGROUND Hysteroscopic-guided biopsy is the gold standard for endometrial sampling, but it carries risk of general anaesthesia, infection and perforation, whereas Pipelle does not require anaesthesia or cervical dilatation and it allows outpatient and painless endometrial sampling. The aim of the study is to determine the reliability and accuracy of Pipelle aspiration in acquiring an adequate and representative endometrial sample and to compare its histopathology with hysteroscopic-directed biopsy. MATERIALS AND METHODS A prospective observational comparative study evaluating the role of Pipelle aspiration as an outpatient procedure in endometrial sampling of perimenopausal women with AUB. 150 perimenopausal women with clinical diagnosis of abnormal uterine bleeding were selected from the Gynaecology OPD of IOG, Chennai, between October 2014 and September 2015. They were subjected to endometrial sampling by Pipelle followed by hysteroscopic-directed biopsy. The efficacy of Pipelle was determined by correlating the histopathological results obtained from it and the hysteroscopic-directed biopsy. RESULTS The histopathology of the endometrium obtained using Pipelle’s curette showed a sensitivity of 93%, specificity of 90% in the detection of abnormal findings with PPV of 88% and NPV of 94%. However, accuracy of Pipelle is found to be less in the diagnosis of polyps and submucous fibroids with accuracy of nearing 100% when using hysteroscopy. CONCLUSION Pipelle endometrial sampling is convenient, easy, painless and safe in obtaining an adequate sample for histopathology with high sensitivity and specificity for endometrial pathologies and endometrial carcinoma.

  1. Risks and benefits in treatment of mediastinal abscess by endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Tian, Lei; Krimsky, William S; Wu, Qingchen; Sun, Jiayuan

    2017-07-01

    Mediastinal abscess is a fatal condition, treatment of mediastinal abscess is with antibiotics and sometimes surgery for debridement and drainage. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a safe assessment and candidate treatment method of mediastinal lesions. This study aimed to HYPERLINK "javascript:void(0);" discuss risks and benefits in treatment of mediastinal abscess by EBUS-TBNA. We noticed a 56-year-old man with developed bilateral pneumonia and sepsis after puncture of mediastinal abscess by EBUS-TBNA. The patient was successfully treated with a combination of systemic anti-infection treatment and intracavitary administration of antibiotics, antifungal and repeated drainage and lavage via EBUS-TBNA, in 1 year follow-up without recurrence. This study indicated infection spread risk of mediastinal abscess after EBUS-TBNA, and mediastinal abscess was successfully cured by combination of systemic anti-infection and local intervention through EBUS-TBNA. EBUS-TBNA is a potential effective minimally invasive treatment for mediastinal abscess, and it is necessary to be aware of clinical complications after puncture of mediastinal infectious lesions by EBUS-TBNA. © 2015 John Wiley & Sons Ltd.

  2. [Ropivacaine use in transnasal sphenopalatine ganglion block for post dural puncture headache in obstetric patients - case series].

    Science.gov (United States)

    Furtado, Inês; Lima, Isabel Flor de; Pedro, Sérgio

    2018-02-02

    Sphenopalatine ganglion block is widely accepted in chronic pain; however it has been underestimated in post dural puncture headache treatment. The ganglion block does not restore normal cerebrospinal fluid dynamics but effectively reduces symptoms associated with resultant hypotension. When correctly applied it may avoid performance of epidural blood patch. The transnasal approach is a simple and minimally invasive technique. In the cases presented, we attempted to perform and report the ganglion block effectiveness and duration, using ropivacaine. We present four obstetrics patients with post dural puncture headache, after epidural or combined techniques, with Tuohy needle 18G that underwent a safe and successful Sphenopalatine ganglion block. We performed the block 24-48h after dural puncture, with 4mL of ropivacaine 0.75% in each nostril. In three cases pain recurred within 12-48h, although less intense. In one patient a second block was performed with complete relief and without further recurrence. In the other two patients a blood patch was performed without success. All patients were asymptomatic within 7 days. The average duration of analgesic effect of the block remains poorly defined. In the cases reported, blocking with ropivacaine was a simple, safe and effective technique, with immediate and sustained pain relief for at least 12-24h. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  3. [Clinical value of CT-guided high frequency-induced thermotherapy as a treatment for intrahepatic cholangiocarcinoma].

    Science.gov (United States)

    Fan, Wei-Jun; Zhang, Liang; Gu, Yang-Kui; Wang, Li-Gang; Ouyang, Yu-Shu

    2008-07-01

    To evaluate the therapeutic effect of CT-guided high frequency-induced thermotherapy (HiTT) for intrahepatic cholangiocarcinoma. Seventeen patients of intrahepatic cholangiocarcinoma with 21 lesions underwent comprehensive treatment with HiTT as the principle approach. As to the patients with obstructive jaundice, percutaneous trans-hepatic cholangial drainage (PTCD) or bile duct endoprosthesis placement was performed first to improve the liver function, then HiTT was performed; and patients without obstructive jaundice underwent CT-guided HiTT directly, 1-2 weeks later, chemotherapy was given for 4 - 6 courses. CT scan 1 week after HiTT showed a short-term achievement rate of 100% (17/17), and the single puncture in situ ablation rate was 76.1% (16/21). The average life span in the near future was 13.5 months. The adverse effects included topo-bleeding, pain after procedure, liver function damage, defervescence, etc. All the patients recovered after symptomatic treatment. The clinical value of CT-guided HiTT for intrahepatic cholangiocarcinoma is obvious.

  4. ST-segment elevation and ventricular fibrillation shortly after transseptal puncture for left atrial catheter ablation

    Directory of Open Access Journals (Sweden)

    Daisuke Ishigaki, MD

    2013-10-01

    Full Text Available A 47-year-old man with drug-resistant paroxysmal atrial fibrillation underwent left atrial (LA catheter ablation. After sheaths were inserted into the LA using the Brockenbrough method, he complained of angina and developed ST-segment elevation in the II, III, aVF, V5, and V6 leads. Ventricular fibrillation (VF occurred followed by ventricular tachycardia. The VF was successfully treated with direct current shock. Coronary angiography with isosorbide dinitrate showed neither spasm nor embolism in the coronary artery. The chest pain disappeared after 6 min with resolution of the ST-segment elevation. A summarized review of ST-segment elevation associated with transseptal puncture disclosed that ST-segment elevation is often found in inferior leads (87.5%, while concomitant bradyarrhythmia has been reported in 43.8% of patients. Our patient is the first recorded case with potentially lethal tachyarrhythmia. Although ST-segment elevation and VF is a rare complication associated with transseptal puncture, awareness of this complication is important.

  5. Shrunk loop theorem for the topology probabilities of closed Brownian (or Feynman) paths on the twice punctured plane

    International Nuclear Information System (INIS)

    Giraud, O; Thain, A; Hannay, J H

    2004-01-01

    The shrunk loop theorem proved here is an integral identity which facilitates the calculation of the relative probability (or probability amplitude) of any given topology that a free, closed Brownian (or Feynman) path of a given 'duration' might have on the twice punctured plane (plane with two marked points). The result is expressed as a 'scattering' series of integrals of increasing dimensionality based on the maximally shrunk version of the path. Physically, this applies in different contexts: (i) the topology probability of a closed ideal polymer chain on a plane with two impassable points, (ii) the trace of the Schroedinger Green function, and thence spectral information, in the presence of two Aharonov-Bohm fluxes and (iii) the same with two branch points of a Riemann surface instead of fluxes. Our theorem starts from the Stovicek scattering expansion for the Green function in the presence of two Aharonov-Bohm flux lines, which itself is based on the famous Sommerfeld one puncture point solution of 1896 (the one puncture case has much easier topology, just one winding number). Stovicek's expansion itself can supply the results at the expense of choosing a base point on the loop and then integrating it away. The shrunk loop theorem eliminates this extra two-dimensional integration, distilling the topology from the geometry

  6. Closure Using a Surgical Closure Device of Inadvertent Subclavian Artery Punctures During Central Venous Catheter Placement

    International Nuclear Information System (INIS)

    Berlet, Matthew H.; Steffen, Diana; Shaughness, George; Hanner, James

    2001-01-01

    Severe complications can and do occur when central venous catheters are inadvertently placed into subclavian arteries. Two cases are discussed that describe how these inadvertent arterial punctures can be closed using the Perclose device (Abbott Laboratories, Redwood City, CA, USA)

  7. Experimental study on venography with carbon dioxide by fine-needle direct-puncture of abdominal viscera

    International Nuclear Information System (INIS)

    Zhu Chi; Xu Changliang; Zhang Dezhi; Zheng Feiqun; Sheng Qiang; Zhang Xiuze; Xiong Zhuang; Yu Yongqiang

    2005-01-01

    Objective: To evaluate the feasibility and safety of CO 2 venography by fine-needle direct-puncture of abdominal viscera. Methods: Two healthy female pigs and two healthy female dogs were used in this study. Multi-point punctures of abdominal viscera including liver, spleen, kidney, pancreas, walls of small intestines, and uterus with 25-gauge needle were performed for CO 2 venography in all animals. Diagnostic image quality of the angiographic images was assessed by 3 independent observers. Results: Splenic-portal vein, hepatic vein, portal vein, renal vein and inferior vena cava, uterine vein and ovarian vein could be visualized by fine needle direct CO 2 injection into the related organic parenchyma, while draining vein of small intestines and pancreas could not be shown. Splenic-portal veins were revealed especially well with grade A of 87.5% (7/8) , grade B of 12.5% (1/8), and grade C of 0%. The image quality of hepatic veins were 81.8% (9/11), 18.2% (2/11), and 0% for grade A, B, and C, respectively. The portal veins were 77.8% (7/9), 22.2%(2/9), and 0% for grade A, B, and C, respectively. The renal vein and inferior vena cava were 38.5% (5/13), 61.5% (8/13), and 0% for grade A, B, and C respectively. The uterine veins and ovarian veins were 0%, 33.3% (2/6), and 66.7% (4/6) for grade A, B, and C, respectively. During the CO 2 angiographic procedure, vital signs remained stable in all animals. Conclusion: CO 2 venography with fine-needle direct-puncture of abdominal viscera, excluding small intestines and pancreas, is feasible and safe. (authors)

  8. Rapid Clearance of Lateral Ventricular Hematoma via Frontal Eminence Puncture and Aspiration: A Technical Note.

    Science.gov (United States)

    Li, Zhaojian; Yao, Weicheng; Han, Kun; Lan, Xiaolei; Bo, Yongli

    2017-01-01

    Background  Intraventricular extension of a parenchymal hemorrhage is an independent predictor of poor outcome and might be complicated by delayed hydrocephalus. We describe a method for the rapid and effective removal of a lateral ventricular hematoma via catheter-based puncture and aspiration. Methods  A catheter-based aspiration of a ventricular hematoma via a frontal eminence (FE) puncture was performed in 10 patients with thalamic and ganglionic hemorrhage perforating into the lateral ventricle. Paralleling the long axis of the lateral ventricle, a flexible silicone catheter was moved anteroposteriorly and rotated simultaneously to facilitate clot aspiration and removal. Computed tomography scans before and after surgery were compared for assessment of ventricular clot volume, Graeb score, and the ventriculocranial ratio (VCR). The Glasgow Coma Scale (GCS) score and Glasgow Outcome Scale (GOS) score were assessed at 14 days and 12 months following surgery, respectively. Results  In all 10 patients, catheter-based aspiration resulted in substantial hematoma removal with a clearance rate of 64.9%, a reduced Graeb score by 61.8%, and an elevated GCS score by 52.7%. The procedure was performed safely without occurrence of another hemorrhage, infection, and catheter obstruction in any case. At 12-month follow-up, VCR was reduced by 22.5%, no delayed hydrocephalus occurred, and a favorable outcome with an average GOS of 4.6 was observed in this small cohort of patients. Conclusion  Catheter-based aspiration of a ventricular hematoma via FE puncture rapidly, efficiently, and safely reduced the clot in the ventricular system, prevented delayed hydrocephalus sufficiently, and produced a favorable outcome. Georg Thieme Verlag KG Stuttgart · New York.

  9. Evaluation of a novel Seldinger-needle for computed tomography guided interventions: initial experiences; Evaluierung einer neuen Seldinger-Nadel fuer computertomografisch gesteuerte Interventionen: Erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Plumhans, C.; Mahnken, A.; Iwa, R.; Behrendt, F.F.; Sebastian, K.; Guenther, R.W.; Honnef, D. [Universitaetsklinikum RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2009-02-15

    To evaluate a new Seldinger puncture device for computed tomography-guided interventions under difficult conditions, to analyze applicability, and to investigate assets and drawbacks. From November 2007 to March 2008, we performed CT-guided interventions in 16 patients (7 women, 9 men; mean age 62 years old) using a new 20G-Seldinger needle (Sika-Med, Wiehl, Germany). This novel needle serves as a guide for many different interventional devices due to a guide wire welded on the proximal needle end. It allows continuous application of anesthesia via four tiny holes at the distal needle end until the region of interest is reached. Each intervention was subject to difficult interventional conditions. The indications for intervention were drainage (n = 7), Trucut biopsy of tumor (n = 8) and radiofrequency ablation (n = 1). Handling, success, advantages, drawbacks, complications and patient tolerance were noted after each procedure. A pain scale from 1 - 10 was used to grade the pain level during the intervention. All interventions were performed successfully and no severe complications were observed. Patient tolerance was very good resulting in a mean pain score of 2 {+-} 1. Regions with dangerous and difficult access were successfully reached with the new Seldinger needle in 15 of 16 cases by dilatation of the puncture tract and continuous administration of local anesthesia via the system. Furthermore, different devices such as Trucut systems and a drainage catheter were able to be inserted without complication via the needle. With a proximal removable luer-lock connection, liquid material was able to be aspirated in six cases. Under difficult interventional conditions, the use of a Seldinger needle as a reliable technique for CT-guided interventions can provide a safe and successful procedure. (orig.)

  10. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Takenaka, Daisuke; Imai, Masatake; Ohbayashi, Chiho; Sugimura, Kazuro

    2004-01-01

    Objective: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. Materials and methods: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. Results: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P<0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P<0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P<0.05). Conclusion: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time

  11. The Use of ExoSeal Vascular Closure Device for Direct Antegrade Superficial Femoral Artery Puncture Site Hemostasis

    Energy Technology Data Exchange (ETDEWEB)

    Rimon, Uri, E-mail: rimonu@sheba.health.gov.il; Khaitovich, Boris, E-mail: borislena@012.net.il [Tel-Aviv University, Diagnostic and Interventional Imaging Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel); Yakubovich, Dmitry, E-mail: Dmitry.Yakubovitch@sheba.health.gov.il [Tel-Aviv University, Vascular Surgery Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel); Bensaid, Paul, E-mail: paulbensaid@hotmail.com; Golan, Gil, E-mail: gilgolan201@gmail.com [Tel-Aviv University, Diagnostic and Interventional Imaging Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel); Silverberg, Daniel, E-mail: Daniel.Silverberg@sheba.health.gov.il [Tel-Aviv University, Vascular Surgery Department, Chaim Sheba Medical Center, Tel-Hashomer, Affiliated to the Sackler School of Medicine (Israel)

    2015-06-15

    PurposeThis study was designed to assess the efficacy and safety of the ExoSeal vascular closure device (VCD) to achieve hemostasis in antegrade access of the superficial femoral artery (SFA).MethodsWe retrospectively reviewed the outcome of ExoSeal VCD used for hemostasis in 110 accesses to the SFA in 93 patients between July 2011 and July 2013. All patients had patent proximal SFA based on computer tomography angiography or ultrasound duplex. Arterial calcifications at puncture site were graded using fluoroscopy. The SFA was accessed in an antegrade fashion with ultrasound or fluoroscopic guidance. In all patients, 5–7F vascular sheaths were used. The ExoSeal VCD was applied to achieve hemostasis at the end of the procedure. All patients were clinically examined and had ultrasound duplex exam for any puncture site complications during the 24 h postprocedure.ResultsIn all procedures, the ExoSeal was applied successfully. We did not encounter any device-related technical failure. There were four major complications in four patients (3.6 %): three pseudoaneurysms, which were treated with direct thrombin injection, and one hematoma, which necessitated transfusion of two blood units. All patients with complications were treated with anticoagulation preprocedure or received thrombolytic therapy.ConclusionsThe ExoSeal VCD can be safely used for antegrade puncture of the SFA, with a high procedural success rate (100 %) and a low rate of access site complications (3.6 %)

  12. Prospective Nonrandomized Trial of Manual Compression and Angio-Seal and Starclose Arterial Closure Devices in Common Femoral Punctures

    International Nuclear Information System (INIS)

    Ratnam, Lakshmi A.; Raja, Jowad; Munneke, Graham J.; Morgan, Robert A.; Belli, Anna-Maria

    2007-01-01

    We compared the use of manual compression and Angio-Seal and Starclose arterial closure devices to achieve hemostasis following common femoral artery (CFA) punctures in order to evaluate safety and efficacy. A prospective nonrandomized, single-center study was carried out on all patients undergoing CFA punctures over 1 year. Hemostasis was achieved using manual compression in 108 cases, Angio-Seal in 167 cases, and Starclose in 151 cases. Device-failure rates were low and not significantly different in the two groups (manual compression and closure devices; p = 0.8). There were significantly more Starclose (11.9%) patients compared to Angio-Seal (2.4%), with successful initial deployment subsequently requiring additional manual compression to achieve hemostasis (p < 0.0001). A significant number of very thin patients failed to achieve hemostasis (p = 0.014). Major complications were seen in 2.9% of Angio-Seal, 1.9% of Starclose, and 3.7% of manual compression patients, with no significant difference demonstrated; 4.7% of the major complications were seen in female patients compared to 1.3% in males (p = 0.0415). All three methods showed comparable safety and efficacy. Very thin patients are more likely to have failed hemostasis with the Starclose device, although this did not translate into an increased complication rate. There is a significant increased risk of major puncture-site complications in women with peripheral vascular disease

  13. Removal of non-deflatable retained foley catheter in the bladder by percutaneous puncture of catheter balloon

    International Nuclear Information System (INIS)

    Yoo, Jae Duk; Kim, Jae Kyu; Park, Jin Gyun; Chung, Hyon De

    1988-01-01

    Nondeflatable Foley catheter in the bladder is an uncommon event. We recently experienced a patient in whom the urologist were unable to remove a Foley catheter with cystoscope due to public bone fractures. The procedure, which was successfully carried out, consists of puncturing the ballon under fluoroscope.

  14. Development of Postdural Puncture Headache Following Therapeutic Acupuncture Using a Long Acupuncture Needle

    OpenAIRE

    Jo, Dae-Jean; Lee, Bong Jae; Sung, Joon Kyung; Yi, Jae-Woo

    2010-01-01

    Acupuncture appears to be a clinically effective treatment for acute and chronic pain. A considerable amount of research has been conducted to evaluate the role that acupuncture plays in pain suppression; however, few studies have been conducted to evaluate the side effects of the acupuncture procedure. This case report describes a suspected postdural puncture headache following acupuncture for lower back pain. Considering the high opening pressure, cerebrospinal fluid leakage, and the patien...

  15. Safety assessment technology on the free drop impact and puncture analysis of the cask for radioactive material transport

    International Nuclear Information System (INIS)

    Lee, Dew Hey; Lee, Young Shin; Ryu, Chung Hyun; Kim, Hyun Su; Lee, Ho Chul; Hong, Song Jin; Choi, Young Jin; Lee, Jae Hyung; Na, Jae Yun

    2001-03-01

    In this study, the regulatory condition and analysis condition is analyzed for the free drop and puncture impact analysis to develop the safety assessment technology. Impact analysis is performed with finite element method which is one of the many analysis methods of the shipping cask. LS-DYNA3D and ABAQUS is suitable for the free drop and the puncture impact analysis of the shipping cask. For the analysis model, the KSC-4 that is the shipping cask to transport spent nuclear fuel is investigated. The results of both LS-DYNA3D and ABAQUS is completely corresponded. And The integrity of the shipping cask is verified. Using this study, the reliable safety assessment technology is supplied to the staff. The efficient and reliable regulatory tasks is performed using the standard safety assessment technology

  16. Safety assessment technology on the free drop impact and puncture analysis of the cask for radioactive material transport

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dew Hey [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of); Lee, Young Shin; Ryu, Chung Hyun; Kim, Hyun Su; Lee, Ho Chul; Hong, Song Jin; Choi, Young Jin; Lee, Jae Hyung; Na, Jae Yun [Chungnam National Univ., Taejon (Korea, Republic of)

    2001-03-15

    In this study, the regulatory condition and analysis condition is analyzed for the free drop and puncture impact analysis to develop the safety assessment technology. Impact analysis is performed with finite element method which is one of the many analysis methods of the shipping cask. LS-DYNA3D and ABAQUS is suitable for the free drop and the puncture impact analysis of the shipping cask. For the analysis model, the KSC-4 that is the shipping cask to transport spent nuclear fuel is investigated. The results of both LS-DYNA3D and ABAQUS is completely corresponded. And The integrity of the shipping cask is verified. Using this study, the reliable safety assessment technology is supplied to the staff. The efficient and reliable regulatory tasks is performed using the standard safety assessment technology.

  17. MR-guided direct arthrography of the glenohumeral joint

    International Nuclear Information System (INIS)

    Soh, E.; Bearcroft, P.W.P.; Graves, M.J.; Black, R.; Lomas, D.J.

    2008-01-01

    Aim: To evaluate the feasibility of magnetic resonance (MR)-guided direct arthrography of the glenohumeral joint with a 1.5 T MR system, performing the entire procedure in a single MR examination. Materials and methods: MR-guided direct arthrography was performed on 11 patients. MR imaging guidance and interactive MR fluoroscopy, with in-room control and display system, were used for needle placement and contrast medium injection. The outcome measures were success or failure of joint puncture, the time taken for introduction of contrast medium, and the diagnostic quality of the subsequent MR arthrography images. Results: Contrast medium was successfully instilled into the joint and diagnostic quality MR arthrography images were obtained in all cases. The median time from initial placement of the skin marker to introduction of the contrast medium was 17 min (range 11-29 min). There were no immediate post-procedure complications. Conclusion: Accurate needle placement is feasible in a single MR examination on a commercial 1.5 T closed-bore MR system, using an in-room control and display system together with interactive fluoroscopic imaging, and this was used to provide direct MR arthrography in this study

  18. Study of CT-guided percutaneous biopsy for the spine lesions

    International Nuclear Information System (INIS)

    Zhang Ji; Wu Chungen; Cheng Yongde; Zhu Xuee; Gu Yifeng; Zhang Huijian

    2008-01-01

    Objective: To determine the successful rate, diagnostic accuracy and clinical usefulness of CT-guided percutaneous biopsy for the spine lesions. Methods: Eight-five patients (61 outpatients, 24 ward patients)underwent CT-guided percutaneous biopsy for the spine lesion. The imaging appearance of spinal lesions were lytic in 57 cases, osteosclerotic in 19 cases, and mixed in 9 cases. Biopsy specimens were sent for cytologic and histologic analysis in order to correct diagnosis. Bacterial studies were performed when ever infection was suspected. Results: The localization of puncture biopsy needle inside the spinal lesions, was conformed by computed tomography including 3 cervical, 26 thoracic, 37 lumbar, and 19 sacral lesions. Biopsy specimens included bone (29 cases), soft tissue (5 cases), mixed tissue (47 cases )and no specimen be obtained(4 cases). An adequate specimen for pathologic examination was obtained in 81 biopsies (95%). The pathologic examinations revealed 44 metastases, 17 primary bone neoplasms, 18 infections (included tuberculosis)and 2 normal tissues of vertebral body. The diagnostic accuracy reached 97.5% (79 of 81 patients). Conclusions: CT-guided percutaneous biopsy is an important tool in the evaluation of spinal lesions, providing accurate localization, less trauma and reliable pathologic diagnosis and worthwhile to be the routine before vertebroplasy. (authors)

  19. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Eichler, Katrin, E-mail: k.eichler@em.uni-frankfurt.d [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Walcher, Felix; Marzi, Ingo [Department of Trauma, Hand and Reconstructive Surgery, University of Frankfurt, Frankfurt (Germany); Moritz, Anton [Department of Thoracic and Cardiovascular Surgery, University of Frankfurt, Frankfurt (Germany); Vogl, Thomas J.; Mack, Martin G. [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany)

    2010-07-15

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  20. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    International Nuclear Information System (INIS)

    Eichler, Katrin; Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar; Walcher, Felix; Marzi, Ingo; Moritz, Anton; Vogl, Thomas J.; Mack, Martin G.

    2010-01-01

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  1. CT-guided cervical interlaminar epidural steroid injection for cervical radiculopathy

    International Nuclear Information System (INIS)

    Chen Wei; Wu Chungen; Wu Chaoxian; Cheng Yongde

    2009-01-01

    Objective: To evaluate the safety and effectiveness of CT-guided cervical interlaminar epidural steroid injection for the treatment of cervical radiculopathy. Methods: CT-guided cervical interlaminar epidural steroid injection was performed in 32 patients with cervical radioculopathy, encountered during the period of Dec. 2006 to June 2008, as the patients failed to respond to the conservative treatment in 2 weeks. The clinical data and the imaging findings were retrospectively analyzed. Before and after the procedure, visual analogue scale (VAS) and Odom criteria were used to evaluate the pain of the patient. Results: Three months after the injection, improvement judged by Odom criteria was seen in 28 patients (87.5%), and the mean pain relief value of VAS was 5.88 ± 1.10. No significant difference in effective rate and in VAS score (P>0.05) was found between protrusion group and degenerative group, between the group with the course over 6 months and the group with the course below 6 months, also between the group receiving one injection and the group receiving the second injection. Conclusion: CT-guided fine needle (23 gauge) puncture epidural steroid (Decadron) 'target spot' injection is an ideal alternative for the treatment of cervical radiculopathy, especially for the patients who fails to respond to the conservative treatment. (authors)

  2. Design of ACM system based on non-greedy punctured LDPC codes

    Science.gov (United States)

    Lu, Zijun; Jiang, Zihong; Zhou, Lin; He, Yucheng

    2017-08-01

    In this paper, an adaptive coded modulation (ACM) scheme based on rate-compatible LDPC (RC-LDPC) codes was designed. The RC-LDPC codes were constructed by a non-greedy puncturing method which showed good performance in high code rate region. Moreover, the incremental redundancy scheme of LDPC-based ACM system over AWGN channel was proposed. By this scheme, code rates vary from 2/3 to 5/6 and the complication of the ACM system is lowered. Simulations show that more and more obvious coding gain can be obtained by the proposed ACM system with higher throughput.

  3. Prospective evaluation of the radiologist's hand dose in CT-guided interventions; Prospektive Evaluation der Handdosis des Radiologen im Rahmen von CT-gestuetzten Interventionen

    Energy Technology Data Exchange (ETDEWEB)

    Rogits, B.; Jungnickel, K.; Loewenthal, D.; Dudeck, O.; Pech, M.; Ricke, J. [Magdeburg Univ. (Germany). Radiology and Nuclear Medicine; Kropf, S. [Magdeburg Univ. (Germany). Dept. of Biometry and Medical Informatics; Nekolla, E.A. [The Federal Office for Radiation Protection, Neuherberg (Germany). Dept. of Radiation Protection and Health; Wieners, G. [Charite CVC, Berlin (Germany). Dept. of Radiology

    2013-11-15

    Purpose: Assessment of radiologist's hand dose in CT-guided interventions and determination of influencing factors. Materials and Methods: The following CT-guided interventions were included: Core biopsy, drainage, periradicular therapy, and celiac plexus neurolysis. The hand dose was measured with an immediately readable dosimeter, the EDD-30 (Unfors, Sweden). The default parameters for CT fluoroscopy were 120 kV, 90 mA and a 4 mm slice thickness. All interventions were performed on a 16-slice CT unit (Aquilion 16 Toshiba, Japan). The tumor size, degree of difficulty (1 - 3), level of experience and device parameters (mAs, dose-length product, scan time) were documented. Results: 138 CT-guided interventions (biopsy n = 99, drainage n = 23, pain therapy n = 16) at different locations (lung n = 41, retroperitoneum n = 53, liver n = 25, spine n = 19) were included. The lesion size was 4 - 240 mm (median: 23 mm). The fluoroscopy time per intervention was 4.6 - 140.2 s (median: 24.2 s). The measured hand dose ranged from 0.001 - 3.02 mSv (median: 0.22 mSv). The median hand dose for lung puncture (n = 41) was slightly higher (median: 0.32 mSv, p = 0.01) compared to that for the liver, retroperitoneum and other. Besides physical influencing factors, the degree of difficulty (p = 0.001) and summed puncture depth (p = 0.004) correlated significantly with the hand dose. Conclusion: The median hand dose for different CT-guided interventions was 0.22 mSv. Therefore, the annual hand dose limit would normally only be reached with about 2000 interventions. (orig.)

  4. CT-guided percutaneous neurolysis methods. State of the art and first results

    International Nuclear Information System (INIS)

    Schneider, B.; Richter, G.M.; Roeren, T.; Kauffmann, G.W.

    1996-01-01

    We used 21G or 22G fine needles. All CT-guided percutaneous neurolysis methods require a proper blood coagulation. Most common CT scanners are suitable for neurolysis if there is enough room for maintaining sterile conditions. All neurolysis methods involve sterile puncture of the ganglia under local anesthesia, a test block with anesthetic and contrast agent to assess the clinical effect and the definitive block with a mixture of 96% ethanol and local anesthetic. This allows us to correct the position of the needle if we see improper distribution of the test block or unwanted side effects. Though inflammatory complications of the peritoneum due to puncture are rarely seen, we prefer the dorsal approach whenever possible. Results: Seven of 20 legs showed at least transient clinical improvement after CT-guided lumbar sympathectomies; 13 legs had to be amputated. Results of the methods in the literature differ. For lumbar sympathectomy, improved perfusion is reported in 39-89%, depending on the pre-selection of the patient group. Discussion: It was recently proved that sympathectomy not only improves perfusion of the skin but also of the muscle. The hypothesis of a steal effect after sympathectomy towards skin perfusion was disproved. Modern aggressive surgical and interventional treatment often leaves patients to sympathectomy whose reservers of collateralization are nearly exhausted. We presume this is the reason for the different results we found in our patient group. For thoracic sympathectomy the clinical treatment depends very much on the indications. Whereas palmar hyperhidrosis offers nearly 100% success, only 60-70% of patients with disturbance of perfusion have benefited. Results in celiac ganglia block also differ. Patients with carcinoma of the pancreas and other organs of the upper abdomen benefit in 80-100% of all cases, patients with chronic pancreatitis in 60-80%. (orig./VHE) [de

  5. Ultrasound guided implantation of chest port systems via the lateral subclavian vein

    International Nuclear Information System (INIS)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K.; Warm, M.; Reiser, M.; Toex, U.

    2006-01-01

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  6. Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments

    Energy Technology Data Exchange (ETDEWEB)

    Penzkofer, Tobias; Isfort, Peter; Bruners, Philipp; Mahnken, Andreas H. [RWTH Aachen University, Applied Medical Engineering, Helmholtz-Institute Aachen, Aachen (Germany); RWTH Aachen University, Department of Diagnostic Radiology, Aachen University Hospital, Aachen (Germany); Wiemann, Christian; Guenther, Rolf W. [RWTH Aachen University, Department of Diagnostic Radiology, Aachen University Hospital, Aachen (Germany); Kyriakou, Yiannis; Kalender, Willi A. [Friedrich-Alexander University of Erlangen-Nuremberg, Institute for Medical Physics, Erlangen (Germany); Schmitz-Rode, Thomas [RWTH Aachen University, Applied Medical Engineering, Helmholtz-Institute Aachen, Aachen (Germany)

    2010-11-15

    To evaluate accuracy and procedure times of electromagnetic tracking (EMT) in a robotic arm mounted flat panel setting using phantom and animal cadaveric models. A robotic arm mounted flat panel (RMFP) was used in combination with EMT to perform anthropomorphic phantom (n = 90) and ex vivo pig based punctures (n = 120) of lumbar facet joints (FJ, n = 120) and intervertebral discs (IVD, n = 90). Procedure accuracies and times were assessed and evaluated. FJ punctures were carried out with a spatial accuracy of 0.8 {+-} 0.9 mm (phantom) and 0.6 {+-} 0.8 mm (ex vivo) respectively. While IVD punctures showed puncture deviations of 0.6 {+-} 1.2 mm (phantom) and 0.5 {+-} 0.6 mm (ex vivo), direct and angulated phantom based punctures had accuracies of 0.8 {+-} 0.9 mm and 1.0 {+-} 1.3 mm. Planning took longer for ex vivo IVD punctures compared to phantom model interventions (39.3 {+-} 17.3 s vs. 20.8 {+-} 5.0 s, p = 0.001) and for angulated vs. direct phantom FJ punctures (19.7 {+-} 5.1 s vs. 28.6 {+-} 7.8 s, p < 0.001). Puncture times were longer for ex vivo procedures when compared to phantom model procedures in both FJ (37.9 {+-} 9.0 s vs. 23.6 {+-} 7.2 s, p = 0.001) and IVD punctures (43.9 {+-} 16.1 s vs. 31.1 {+-} 6.4 s, p = 0.026). The combination of RMFP with EMT provides an accurate method of navigation for spinal interventions such as facet joint punctures and intervertebral disc punctures. (orig.)

  7. Curative effect of minimally invasive puncture and drainage assisted with alteplase on treatment of acute intracerebral hemorrhage

    Directory of Open Access Journals (Sweden)

    Jun-Lin Hu

    2017-01-01

    >Conclusions: As for the effect on evacuation of hematoma and also the ameliorative effect on nerve injury, inflammatory reaction and oxidative stress response in treatment of acute intracerebral hemorrhage, minimally invasive puncture and drainage assisted with alteplase was superior to adjuvant therapy with urokinase.

  8. Under Utilization of Local Anesthetics in Infant Lumbar Punctures

    Directory of Open Access Journals (Sweden)

    Gorchynski, Julie

    2008-01-01

    Full Text Available Background: Lumbar Puncture (LP is an invasive procedure frequently used to diagnose meningitis among the pediatric population. Neonates and infants have not routinely received local anesthesia prior to LP. Study Objective: To determine whether emergency medicine physicians and pediatricians use local analgesics on neonates and infants prior to performing an LP and to identify which local anesthetics, if any, were used. Methods: Prospective, cohort study of all infants, six months of age or less, that received an LP in the emergency department (ED or inpatient pediatric units for suspected meningitis during a period of year at a university tertiary care hospital. Results: A total sample population of 111 infants that received an LP within the study period. A control population of 42 adults received an LP. Only 40.4% (45/111 of the infants received local analgesia prior to LP: either 1% lidocaine, EMLA or a combination of the two. Infants were less likely to receive lidocaine or EMLA prior to LP compared to adult subjects (OR= 0.27; 95% CI0.12 to 0.62. No neonates that were less than one month of age received local procedural anesthesia by emergency medicine or pediatric physicians. ED physicians’ use of local anesthesia prior to LP increased with increasing age of the infant. The pediatricians in this study used local anesthesia prior to LP when the infant was at least five months of age. Discussion: The data objectively support recent literature regarding the under use or lack of use of analgesia prior to LP among neonates and infants. Local anesthetics should be used routinely without exception prior to performing an LP in the pediatric population.

  9. Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments

    International Nuclear Information System (INIS)

    Penzkofer, Tobias; Isfort, Peter; Bruners, Philipp; Mahnken, Andreas H.; Wiemann, Christian; Guenther, Rolf W.; Kyriakou, Yiannis; Kalender, Willi A.; Schmitz-Rode, Thomas

    2010-01-01

    To evaluate accuracy and procedure times of electromagnetic tracking (EMT) in a robotic arm mounted flat panel setting using phantom and animal cadaveric models. A robotic arm mounted flat panel (RMFP) was used in combination with EMT to perform anthropomorphic phantom (n = 90) and ex vivo pig based punctures (n = 120) of lumbar facet joints (FJ, n = 120) and intervertebral discs (IVD, n = 90). Procedure accuracies and times were assessed and evaluated. FJ punctures were carried out with a spatial accuracy of 0.8 ± 0.9 mm (phantom) and 0.6 ± 0.8 mm (ex vivo) respectively. While IVD punctures showed puncture deviations of 0.6 ± 1.2 mm (phantom) and 0.5 ± 0.6 mm (ex vivo), direct and angulated phantom based punctures had accuracies of 0.8 ± 0.9 mm and 1.0 ± 1.3 mm. Planning took longer for ex vivo IVD punctures compared to phantom model interventions (39.3 ± 17.3 s vs. 20.8 ± 5.0 s, p = 0.001) and for angulated vs. direct phantom FJ punctures (19.7 ± 5.1 s vs. 28.6 ± 7.8 s, p < 0.001). Puncture times were longer for ex vivo procedures when compared to phantom model procedures in both FJ (37.9 ± 9.0 s vs. 23.6 ± 7.2 s, p = 0.001) and IVD punctures (43.9 ± 16.1 s vs. 31.1 ± 6.4 s, p = 0.026). The combination of RMFP with EMT provides an accurate method of navigation for spinal interventions such as facet joint punctures and intervertebral disc punctures. (orig.)

  10. Direct-puncture approach to the extraconal portion of the superior ophthalmic vein for carotid cavernous fistulae

    International Nuclear Information System (INIS)

    Kurata, A.; Suzuki, S.; Iwamoto, K.; Miyazaki, T.; Inukai, M.; Abe, K.; Niki, J.; Yamada, M.; Fujii, K.; Kan, S.

    2009-01-01

    The transvenous approach via the superior ophthalmic vein (SOV) is an available approach for carotid cavernous fistula (CCF), especially in the event that there is no other suitable approach route to the fistula. Surgical exposure of the peripheral roots of the SOV is commonly used; however, often, the SOV is often not accessible because of anatomical problems and/or complications. In this paper, we present and discuss our original direct-puncture approach to the extraconal portion of the SOV. An attempt on three patients with traumatic CCF failed with the transarterial approach and the conventional venous approach via the inferior petrosal sinus; therefore, the patients were treated with the direct-puncture approach to the extraconal portion of the SOV using two-dimensional digital subtraction angiography with local anesthesia. All cases that had tortuous and partially stenotic division of the SOV were treated successfully with this approach and without complications. This approach will become an alternate approach, especially when the peripheral roots of the SOV are focally narrowed and tortuous, making it impossible to insert a catheter. (orig.)

  11. The use of EURACHEM guide for comparison of two 210Pb determination methods in solid environmental samples

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Hassan, M.; Amin, Y.

    2008-07-01

    Two techniques for determination of 210 Pb in solid environmental samples have been validated and compared according to Eurachem Guide on method validation. The first technique depended on determination of 210 Po, which equilibrium with 210 Pb, by platting it onto a rotating silver disc. Then, Alpha counting of 210 Po was done using an alpha spectrometer. On the other hand, according to its decay scheme, 210 Pb was measured directly through gamma spectrometry by measuring the 46.5 keV. Detection limits, reproducibility and recovery coefficient were the main validation parameters. In addition, uncertainties of measurement were estimated and compared for the two techniques. The comparison results have shown that, the activity of 210 Pb in the environmental samples can choose which technique is appropriated. It was found that Eurachem Guide and comparison of quality statistical validation parameters can be a good tool for selection of the appropriate method for the application. (Authors)

  12. Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments.

    Science.gov (United States)

    Penzkofer, Tobias; Isfort, Peter; Bruners, Philipp; Wiemann, Christian; Kyriakou, Yiannis; Kalender, Willi A; Günther, Rolf W; Schmitz-Rode, Thomas; Mahnken, Andreas H

    2010-11-01

    To evaluate accuracy and procedure times of electromagnetic tracking (EMT) in a robotic arm mounted flat panel setting using phantom and animal cadaveric models. A robotic arm mounted flat panel (RMFP) was used in combination with EMT to perform anthropomorphic phantom (n = 90) and ex vivo pig based punctures (n = 120) of lumbar facet joints (FJ, n = 120) and intervertebral discs (IVD, n = 90). Procedure accuracies and times were assessed and evaluated. FJ punctures were carried out with a spatial accuracy of 0.8 ± 0.9 mm (phantom) and 0.6 ± 0.8 mm (ex vivo) respectively. While IVD punctures showed puncture deviations of 0.6 ± 1.2 mm (phantom) and 0.5 ± 0.6 mm (ex vivo), direct and angulated phantom based punctures had accuracies of 0.8 ± 0.9 mm and 1.0 ± 1.3 mm. Planning took longer for ex vivo IVD punctures compared to phantom model interventions (39.3 ± 17.3 s vs. 20.8 ± 5.0 s, p = 0.001) and for angulated vs. direct phantom FJ punctures (19.7 ± 5.1 s vs. 28.6 ± 7.8 s, p < 0.001). Puncture times were longer for ex vivo procedures when compared to phantom model procedures in both FJ (37.9 ± 9.0 s vs. 23.6 ± 7.2 s, p = 0.001) and IVD punctures (43.9 ± 16.1 s vs. 31.1 ± 6.4 s, p = 0.026). The combination of RMFP with EMT provides an accurate method of navigation for spinal interventions such as facet joint punctures and intervertebral disc punctures.

  13. CT-guided spinal injection: initial experience with Sprotte tip needles

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore)

    2010-09-15

    The purpose of this paper is to describe our initial experience and to illustrate the potential benefits of using small caliber (25 and 27 G), noncutting pencil point needles (Sprotte) with single puncture coaxial technique in CT-guided spinal intervention (CTSI). From January 2009 to June 2009, Sprotte needles with single puncture coaxial technique were used in a total of ten patients for selective nerve root block (SNRB), facet joint block, and pars block under CT fluoroscopy (total of 16 target structures). All procedures were performed without conscious sedation, and visual analog scale (VAS) scores were recorded to determine pain related to needle placement. Total CT fluoroscopy time and out-of-plane needle deviation were obtained. Final needle position was documented by contrast injection for SNRBs and image capture for joint space cannulation. Sixteen out of the 16 structures were successfully targeted. No increase in VAS scores associated with needle placement was recorded, after infiltration of local anesthesia. Optimal peri-neurograms were obtained in all cases of SNRB, despite the side-hole opening in the Sprotte needles. Mean CT fluoroscopy time was 2 s (range 2-8 s per structure), and there was no case of out-of-plane needle deviation that required adjustment of the CT gantry. The use of small caliber Sprotte needles in CTSI is technically feasible and represents a potential refinement to current techniques in the management of chronic spinal pain. (orig.)

  14. Linear-motion tattoo machine and prefabricated needle sets for the delivery of plant viruses by vascular puncture inoculation

    Science.gov (United States)

    Vascular puncture inoculation (VPI) of plant viruses previously has been conducted either manually or by use of a commercial engraving tool and laboratory-fabricated needle arrays. In an effort to improve this technique, a linear-motion tattoo machine driving industry-standard needle arrays was tes...

  15. Individualized laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer.

    Science.gov (United States)

    Xu, Zhifeng; Yang, Zhangwei; Pan, Jianghua; Hu, Yiren

    2018-03-01

    Liver cancer is one of the most common malignancies of the digestive system. Minimally invasive ablation procedures have become one of the major means for treating unresectable multifocal liver cancer and have been extensively applied in primary and metastatic liver cancer treatment. Laparoscopic B-ultrasound-guided microwave ablation is an example of the progress made in this field. To analyze and summarize the results of and experience with laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer; moreover, the ablation effects were compared between tumors of different sizes. Laparoscope-guided needle ablation was conducted on 84 lesions from 32 patients with primary liver cancer based on tumor size, quantity, and location. Moreover, the perioperative data, ablation effects according to tumor size, and long-term follow-up results were analyzed. Among the 84 nodules treated via microwave ablation, tumors measuring ≤ 3 cm demonstrated complete ablation upon imaging analysis conducted 1 month after surgery. Moreover, 5 of the tumors measuring > 3 cm demonstrated incomplete ablation. In these cases, a second procedure was performed, until imaging studies confirmed that complete ablation was achieved. Laparoscopic microwave ablation allows for precise puncture positioning, an effective ablation range, and safe and feasible surgery, which is especially suitable for liver tumors located in sites difficult to access.

  16. Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle.

    Science.gov (United States)

    Tang, Zhouwen; Igbinomwanhia, Efehi; Elhanafi, Sherif; Othman, Mohamed O

    2016-01-01

    Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV) biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-RV biliary drainage procedures at a single center. Patients who failed ERCP during the same session for benign or malignant biliary obstruction underwent EUS-RV using a flexible, nitinol covered, 19-gauge needle for biliary access and guide wire manipulation. Result. 24 patients underwent EUS-RV biliary drainage via extrahepatic access while 1 attempt was via intrahepatic access. The technical success rate was 80%, including 83.3% of cases via extrahepatic access. There was no significant difference in success rate of inpatient and outpatient procedures, benign or malignant indications, or type of guide wire used. Adverse events included mild pancreatitis (3 patients) and cholangitis (1 patient). Conclusion. A flexible 19-gauge needle for biliary access can be safe and effective when used to perform EUS-RV biliary drainage. Direct comparison between the nitinol needle and conventional metal needles in the performance of EUS guided biliary drainage is needed.

  17. In vitro bacterial cytotoxicity of CNTs: reactive oxygen species mediate cell damage edges over direct physical puncturing.

    Science.gov (United States)

    Rajavel, Krishnamoorthy; Gomathi, Rajkumar; Manian, Sellamuthu; Rajendra Kumar, Ramasamy Thangavelu

    2014-01-21

    Understanding the bacterial cytotoxicity of CNTs is important for a wide variety of applications in the biomedical, environmental, and health sectors. A majority of the earlier reports attributed the bactericidal cytotoxicity of CNTs to bacterial cell membrane damage by direct physical puncturing. Our results reveal that bacterial cell death via bacterial cell membrane damage is induced by reactive oxygen species (ROS) produced from CNTs and is not due to direct physical puncturing by CNTs. To understand the actual mechanism of bacterial killing, we elucidated the bacterial cytotoxicity of SWCNTs and MWCNTs against Gram-negative human pathogenic bacterial species Escherichia coli, Shigella sonnei, Klebsiella pneumoniae, and Pseudomonas aeruginosa and its amelioration upon functionalizing the CNTs with antioxidant tannic acid (TA). Interestingly, the bacterial cells treated with CNTs exhibited severe cell damage under laboratory (ambient) and sunlight irradiation conditions. However, CNTs showed no cytotoxicity to the bacterial cells when incubated in the dark. The quantitative assessments carried out by us made it explicit that CNTs are effective generators of ROS such as (1)O2, O2(•-), and (•)OH in an aqueous medium under both ambient and sunlight-irradiated conditions. Both naked and TA-functionalized CNTs showed negligible ROS production in the dark. Furthermore, strong correlations were obtained between ROS produced by CNTs and the bacterial cell mortality (with the correlation coefficient varying between 0.7618 and 0.9891) for all four tested pathogens. The absence of bactericidal cytotoxicity in both naked and functionalized CNTs in the dark reveals that the presence of ROS is the major factor responsible for the bactericidal action compared to direct physical puncturing. This understanding of the bactericidal activity of the irradiated CNTs, mediated through the generation of ROS, could be interesting for novel applications such as regulated ROS delivery

  18. Successful treatment of direct carotid-cavernous fistula in a patient with Ehlers-Danlos syndrome type IV without arterial puncture: the transvenous triple-overlay embolization (TAILOREd) technique.

    Science.gov (United States)

    Huynh, Thien J; Morton, Ryan P; Levitt, Michael R; Ghodke, Basavaraj V; Wink, Onno; Hallam, Danial K

    2017-08-18

    We report successful transvenous treatment of direct carotid-cavernous fistula in a patient with Ehlers-Danlos syndrome type IV using a novel triple-overlay embolization (TAILOREd) technique without the need for arterial puncture, which is known to be highly risky in this patient group. The TAILOREd technique allowed for successful treatment using preoperative MR angiography as a three-dimensional overlay roadmap combined with cone beam CT and live fluoroscopy, precluding the need for an arterial puncture. 2017 BMJ Publishing Group Ltd.

  19. Diagnostic Lumbar Puncture Among Children With Facial Palsy in a Lyme Disease Endemic Area.

    Science.gov (United States)

    Paydar-Darian, Niloufar; Kimia, Amir A; Lantos, Paul M; Fine, Andrew M; Gordon, Caroline D; Gordon, Catherine R; Landschaft, Assaf; Nigrovic, Lise E

    2017-06-01

    We identified 620 children with peripheral facial palsy of which 211 (34%) had Lyme disease. The 140 children who had a lumbar puncture performed were more likely to be hospitalized (73% LP performed vs 2% no LP) and to receive parenteral antibiotics (62% LP performed vs 6% no LP). © The Author 2016. Published by Oxford University Press on behalf of The Journal of the Pediatric Infectious Diseases Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Investigating Efficacy of Melatonin and Gabapentin in Reducing Anxiety and Pain of Lumbar Puncture in Children

    Directory of Open Access Journals (Sweden)

    R Fallah

    2013-10-01

    Full Text Available Introduction: The lumbar puncture is one of the most important diagnostic and therapeutic procedures within children which child’s non-cooperativeness and procedural sedation are regarded necessary to conduct it. This study aimed to compare efficacy and safety of melatonin and gabapentin in reducing anxiety and pain of lumbar puncture in children. Methods: In a parallel single-blinded randomized clinical trial, sixty children aged 6 months -7 years, were evaluated in Pediatric Ward of Shahid Sadoughi Hospital, in Yazd (Iran in 2012. The children were distributedrandomly into two groups (30 children in each group. In group one, they received 0.3 mg/kg/dose of melatonin and theother group received 15 mg/kg/dose of gabapentin. Primary endpoints were success rate in reducing anxiety (anxiety score of≥ four and reducing pain when the needle was inserted to skin for lumbarpuncture (pain score of less than four. The clinicalside effects were investigated as well. Results: Twenty two girls (36.7% and 38 boys (63.3% with mean age of 2.79 ± 1.92 years were evaluated. Anxiety reduction (achieving the anxiety score of ≥ four was obtained in 43.3% in melatonin and in 36.7% in gabapentin groups, respectively and both drugs were equally effective in anxiety reduction (p.value = 0.598.Pain reduction ( achieving the pain score of less than four was obtained in 23.3% in melatonin and in 50% in gabapentin groups, respectively and thus, gabapentin wasproved to be more effective in pain reduction (p.value = 0.032.Mild side effects were observed in 10% of melatonin group and in 16.7% of gabapentin group. No statistically significant differences were seen from viewpoint of safety between the two drugs (p.value=0.448. Conclusion: Melatonin and gabapentin were not effective drugs in anxiety reduction for lumbar puncture of children. However, gabapentin is a safe and effective drug in pain reduction in painful diagnostic therapeutic procedures.

  1. Endoscopic Ultrasound-guided Rendezvous Technique after Failed Endoscopic Retrograde Cholangiopancreatography: Which Approach Route Is the Best?

    Science.gov (United States)

    Okuno, Nozomi; Hara, Kazuo; Mizuno, Nobumasa; Hijioka, Susumu; Tajika, Masahiro; Tanaka, Tsutomu; Ishihara, Makoto; Hirayama, Yutaka; Onishi, Sachiyo; Niwa, Yasumasa; Yamao, Kenji

    2017-12-01

    Objective The endoscopic ultrasound-guided rendezvous technique (EUS-RV) is a salvage method for failed selective biliary cannulation. Three puncture routes have been reported, with many comparisons between the intra-hepatic and extra-hepatic biliary ducts. We used the trans-esophagus (TE) and trans-jejunum (TJ) routes. In the present study, the utility of EUS-RV for biliary access was evaluated, focusing on the approach routes. Methods and Patients In 39 patients, 42 puncture routes were evaluated in detail. EUS-RV was performed between January 2010 and December 2014. The patients were prospectively enrolled, and their clinical data were retrospectively collected. Results The patients' median age was 71 (range 29-84) years. The indications for endoscopic retrograde cholangiopancreatography (ERCP) were malignant biliary obstruction in 24 patients and benign biliary disease in 15. The technical success rate was 78.6% (33/42) and was similar among approach routes (p=0.377). The overall complication rate was 16.7% (7/42) and was similar among approach routes (p=0.489). However, mediastinal emphysema occurred in 2 TE route EUS-RV patients. No EUS-RV-related deaths occurred. Conclusion EUS-RV proved reliable after failed ERCP. The selection of the appropriate route based on the patient's condition is crucial.

  2. Blood Sampling in Newborns: A Systematic Review of YouTube Videos.

    Science.gov (United States)

    Bueno, Mariana; Nishi, Érika Tihemi; Costa, Taine; Freire, Laís Machado; Harrison, Denise

    Objective of this study was to conduct a systematic review of YouTube videos showing neonatal blood sampling, and to evaluate pain management and comforting interventions used. Selected videos were consumer- or professional-produced videos showing human newborns undergoing heel lancing or venipuncture for blood sampling, videos showing the entire blood sampling procedure (from the first attempt or puncture to the time of application of a cotton ball or bandage), publication date prior to October 2014, Portuguese titles, available audio. Search terms included "neonate," "newborn," "neonatal screening," and "blood collection." Two reviewers independently screened the videos and extracted the following data. A total of 13 140 videos were retrieved, of which 1354 were further evaluated, and 68 were included. Videos were mostly consumer produced (97%). Heel lancing was performed in 62 (91%). Forty-nine infants (72%) were held by an adult during the procedure. Median pain score immediately after puncture was 4 (interquartile range [IQR] = 0-5), and median length of cry throughout the procedure was 61 seconds (IQR = 88). Breastfeeding (3%) and swaddling (1.5%) were rarely implemented. Posted YouTube videos in Portuguese of newborns undergoing blood collection demonstrate minimal use of pain treatment, and maximal distress during procedures. Knowledge translation strategies are needed to implement effective measures for neonatal pain relief and comfort.

  3. Interactions among biotic and abiotic factors affect the reliability of tungsten microneedles puncturing in vitro and in vivo peripheral nerves: A hybrid computational approach

    Energy Technology Data Exchange (ETDEWEB)

    Sergi, Pier Nicola, E-mail: p.sergi@sssup.it [Translational Neural Engineering Laboratory, The Biorobotics Institute, Scuola Superiore Sant' Anna, Viale Rinaldo Piaggio 34, Pontedera, 56025 (Italy); Jensen, Winnie [Department of Health Science and Technology, Fredrik Bajers Vej 7, 9220 Aalborg (Denmark); Yoshida, Ken [Department of Biomedical Engineering, Indiana University - Purdue University Indianapolis, 723 W. Michigan St., SL220, Indianapolis, IN 46202 (United States)

    2016-02-01

    Tungsten is an elective material to produce slender and stiff microneedles able to enter soft tissues and minimize puncture wounds. In particular, tungsten microneedles are used to puncture peripheral nerves and insert neural interfaces, bridging the gap between the nervous system and robotic devices (e.g., hand prostheses). Unfortunately, microneedles fail during the puncture process and this failure is not dependent on stiffness or fracture toughness of the constituent material. In addition, the microneedles' performances decrease during in vivo trials with respect to the in vitro ones. This further effect is independent on internal biotic effects, while it seems to be related to external biotic causes. Since the exact synergy of phenomena decreasing the in vivo reliability is still not known, this work explored the connection between in vitro and in vivo behavior of tungsten microneedles through the study of interactions between biotic and abiotic factors. A hybrid computational approach, simultaneously using theoretical relationships and in silico models of nerves, was implemented to model the change of reliability varying the microneedle diameter, and to predict in vivo performances by using in vitro reliability and local differences between in vivo and in vitro mechanical response of nerves. - Highlights: • We provide phenomenological Finite Element (FE) models of peripheral nerves to study the interactions with W microneedles • We provide a general interaction-based approach to model the reliability of slender microneedles • We evaluate the reliability of W microneedels to puncture in vivo nerves • We provide a novel synergistic hybrid approach (theory + simulations) involving interactions among biotic and abiotic factors • We validate the hybrid approach by using experimental data from literature.

  4. Interactions among biotic and abiotic factors affect the reliability of tungsten microneedles puncturing in vitro and in vivo peripheral nerves: A hybrid computational approach

    International Nuclear Information System (INIS)

    Sergi, Pier Nicola; Jensen, Winnie; Yoshida, Ken

    2016-01-01

    Tungsten is an elective material to produce slender and stiff microneedles able to enter soft tissues and minimize puncture wounds. In particular, tungsten microneedles are used to puncture peripheral nerves and insert neural interfaces, bridging the gap between the nervous system and robotic devices (e.g., hand prostheses). Unfortunately, microneedles fail during the puncture process and this failure is not dependent on stiffness or fracture toughness of the constituent material. In addition, the microneedles' performances decrease during in vivo trials with respect to the in vitro ones. This further effect is independent on internal biotic effects, while it seems to be related to external biotic causes. Since the exact synergy of phenomena decreasing the in vivo reliability is still not known, this work explored the connection between in vitro and in vivo behavior of tungsten microneedles through the study of interactions between biotic and abiotic factors. A hybrid computational approach, simultaneously using theoretical relationships and in silico models of nerves, was implemented to model the change of reliability varying the microneedle diameter, and to predict in vivo performances by using in vitro reliability and local differences between in vivo and in vitro mechanical response of nerves. - Highlights: • We provide phenomenological Finite Element (FE) models of peripheral nerves to study the interactions with W microneedles • We provide a general interaction-based approach to model the reliability of slender microneedles • We evaluate the reliability of W microneedels to puncture in vivo nerves • We provide a novel synergistic hybrid approach (theory + simulations) involving interactions among biotic and abiotic factors • We validate the hybrid approach by using experimental data from literature

  5. Effect of warm footbath with vibration on arteriovenous fistula puncture-related pain in hemodialysis patients

    OpenAIRE

    Zahra Abbas Ali Madadi; Jalil Azimian; Farzaneh Falahatpishe; Mahmoud Alipour Heidari

    2017-01-01

    Background: Pain and stress of hemodialysis are experienced by more than 50% of patients who are suffering from renal disease; hence decreasing a part of these adverse effects can be effective on individual’s long term coping with hemodialysis. The current study was done to determine the effect of warm footbath with vibration on arteriovenous fistula puncture-related pain in hemodialysis patients. Methods: This clinical trial was conducted on 31 hemodialysis patients in 2014. The patients ...

  6. Magnetic resonance findings associated with intracranial hypotension. A report of three cases occurring after lumbar puncture

    International Nuclear Information System (INIS)

    Galan, J.; Vuelta, R. V.; Oleaga, L.; Grande, D.

    1999-01-01

    The magnetic resonance (MR) findings are presented for three patients who developed intracranial hypotension syndrome following lumbar puncture, one of the most common causes of this complication. All three patients presented the MR findings characteristically associated with this event, consisting of diffuse dural enhancement after administration of a paramagnetic contrast medium, as well as extraaxial collection that played either an accompanying or a causative role. (Author) 7 refs

  7. Obesity: An Independent Risk Factor for Insufficient Hemostasis Using the AngioSeal Vascular Closure Device After Antegrade Puncture

    Energy Technology Data Exchange (ETDEWEB)

    Minko, Peter, E-mail: peterminko@yahoo.com; Katoh, Marcus [University Hospital Saarland, Department of Diagnostic and Interventional Radiology (Germany); Graeber, Stefan [University Hospital Saarland, Institute of Medical Biometry, Epidemiology and Medical Informatics (Germany); Buecker, Arno [University Hospital Saarland, Department of Diagnostic and Interventional Radiology (Germany)

    2012-08-15

    Purpose: This study was designed to investigate the efficacy of the AngioSeal vascular closure device after antegrade puncture of the femoral artery. Methods: In a prospective study, 120 consecutive patients underwent lower limb vascular intervention by an antegrade access to the common femoral artery (CFA). After intervention, a 6F (n = 88) or an 8F (n = 32) AngioSeal vascular closure device was used to achieve hemostasis. The technical success or the cause of failure was documented. In addition, the coagulation status (platelets, INR, prothrombin time, atrial thromboplastin time (PTT)), hypertonus, locoregional habitus of the groin, body mass index (BMI), presence of calcifications, and history of previous surgical interventions of the CFA were evaluated. Results: Hemostasis was achieved in 97 patients (81%). In 12 patients (10%), persistent bleeding of the puncture site required manual compression. In another nine patients (8%) a kink of the sheath obviated the passage of the collagen plug toward the vessel, and in two patients the anchor dislodged out of the vessel, requiring manual compression. There were no significant differences between the groups of successful and unsuccessful sealing regarding the mean platelets (241 vs. 254 * 10{sup 9}/l; P = 0.86), INR (1.06 vs. 1.02; P = 0.52), prothrombin time (90% vs. 90%; P = 0.86), and PTT (30 vs. 31 s; P = 0.82). However, unsuccessful sealing was more likely in obese patients with an increased BMI (26.6 vs. 28.8 kg/m{sup 2}; P = 0.04). Conclusions: Obesity seems to be an independent risk factor for insufficient sealing using the AngioSeal vascular closure device after antegrade puncture of the CFA. In 8% of our patients, hemostasis could not be achieved due to kink of the flexible sheath.

  8. Pierre Gy's sampling theory and sampling practice heterogeneity, sampling correctness, and statistical process control

    CERN Document Server

    Pitard, Francis F

    1993-01-01

    Pierre Gy's Sampling Theory and Sampling Practice, Second Edition is a concise, step-by-step guide for process variability management and methods. Updated and expanded, this new edition provides a comprehensive study of heterogeneity, covering the basic principles of sampling theory and its various applications. It presents many practical examples to allow readers to select appropriate sampling protocols and assess the validity of sampling protocols from others. The variability of dynamic process streams using variography is discussed to help bridge sampling theory with statistical process control. Many descriptions of good sampling devices, as well as descriptions of poor ones, are featured to educate readers on what to look for when purchasing sampling systems. The book uses its accessible, tutorial style to focus on professional selection and use of methods. The book will be a valuable guide for mineral processing engineers; metallurgists; geologists; miners; chemists; environmental scientists; and practit...

  9. Lumbar puncture requirement in acute hemiparesis: diagnosis of tuberculous meningitis after hemiparesis in a child.

    Science.gov (United States)

    Sahin, Sevim; Cansu, Ali; Kamaşak, Tülay; Eyüboğlu, İlker; Esenülkü, Gülnur; Ökten, Ayşenur

    2014-12-01

    Infections are an important acquired cause of cerebral arteriopathy. Tuberculous (TB) meningitis leading to infectious cerebral vasculopathy is a rare cause of acute hemiparesis. A 14-year-old male patient was examined after acute hemiparesis developing within 1 day. Neurological examination revealed total hemiplegia on the left side. Brain MRI findings showed bilateral focal T2-weighted signal hyperintensity in the subcortical and deep white matter regions. There were also areas of restricted diffusion in the right basal ganglia. Although the father had a history of pulmonary TB, the patient had not been given TB prophylaxis because of PPD negativity. At lumbar puncture, opening cerebrospinal fluid (CSF) pressure was 50 cm/H20, CSF protein 66.9 mg/dL, and glucose 54 mg/dL (concurrent blood glucose 93 mg/dL); 170 polymorphonuclear leukocytes per cubic millimeter were present in CSF. Following tests for TB, treatment was started immediately with four anti-TB drugs. TB PCR of CSF and acid-fast bacteria (AFB) staining in gastric aspirate were positive. At clinical follow-up, the patient was able to walk with support at the end of the first month. Various infectious agents have been reported as causes of cerebral vasculopathy. TB, which affects a significant number of patients worldwide, should be kept in mind in terms of cerebral vascular complications. Lumbar puncture is essential in order to diagnose TB meningitis.

  10. The gingival vein as a minimally traumatic site for multiple blood sampling in guinea pigs and hamsters.

    Science.gov (United States)

    Rodrigues, Mariana Valotta; de Castro, Simone Oliveira; de Albuquerque, Cynthia Zaccanini; Mattaraia, Vânia Gomes de Moura; Santoro, Marcelo Larami

    2017-01-01

    Laboratory animals are still necessary in scientific investigation and vaccine testing, but while novel methodological approaches are not available for their replacement, the search for new, humane, easy, and painless methods is necessary to diminish their stress and pain. When multiple blood samples are to be collected from hamsters and guinea pigs, the number of available venipuncture sites-which are greatly diminished in these species in comparison with other rodents due to the absence of a long tail-, harasses animal caregivers and researchers. Thus, this study aimed to evaluate if gingival vein puncture could be used as an additional route to obtain multiple blood samples from anesthetized hamsters and guinea pigs in such a way that animal behavior, well-being or hematological parameters would not be altered. Thus, twelve anesthetized Syrian golden hamsters and English guinea pigs were randomly allocated in two groups: a control group, whose blood samples were not collected, and an experimental group in which blood samples (200 microliters) were collected by gingival vein puncture at weekly intervals over six weeks. Clinical assessment, body weight gain and complete blood cell count were evaluated weekly, and control and experimental animals were euthanized at week seven, when the mentolabial region was processed to histological analyses. Multiple blood sampling from the gingival vein evoked no clinical manifestations or alteration in the behavioral repertoire, nor a statistically significant difference in weight gain in both species. Guinea pigs showed no alteration in red blood cell, leukocyte or platelet parameters over time. Hamsters developed a characteristic pattern of age-related physiological changes, which were considered normal. Histological analyses showed no difference in morphological structures in the interdental gingiva, confirming that multiple blood sampling is barely traumatic. Thus, these results evidence that blood collection from multiple

  11. Accuracy of the HumaSensplus point-of-care uric acid meter using capillary blood obtained by fingertip puncture.

    Science.gov (United States)

    Fabre, Stéphanie; Clerson, Pierre; Launay, Jean-Marie; Gautier, Jean-François; Vidal-Trecan, Tiphaine; Riveline, Jean-Pierre; Platt, Adam; Abrahamsson, Anna; Miner, Jeffrey N; Hughes, Glen; Richette, Pascal; Bardin, Thomas

    2018-05-02

    The uric acid (UA) level in patients with gout is a key factor in disease management and is typically measured in the laboratory using plasma samples obtained after venous puncture. This study aimed to assess the reliability of immediate UA measurement with capillary blood samples obtained by fingertip puncture with the HumaSens plus point-of-care meter. UA levels were measured using both the HumaSens plus meter in the clinic and the routine plasma UA method in the biochemistry laboratory of 238 consenting diabetic patients. HumaSens plus capillary and routine plasma UA measurements were compared by linear regression, Bland-Altman plots, intraclass correlation coefficient (ICC), and Lin's concordance coefficient. Values outside the dynamic range of the meter, low (LO) or high (HI), were analyzed separately. The best capillary UA thresholds for detecting hyperuricemia were determined by receiver operating characteristic (ROC) curves. The impact of potential confounding factors (demographic and biological parameters/treatments) was assessed. Capillary and routine plasma UA levels were compared to reference plasma UA measurements by liquid chromatography-mass spectrometry (LC-MS) for a subgroup of 67 patients. In total, 205 patients had capillary and routine plasma UA measurements available. ICC was 0.90 (95% confidence interval (CI) 0.87-0.92), Lin's coefficient was 0.91 (0.88-0.93), and the Bland-Altman plot showed good agreement over all tested values. Overall, 17 patients showed values outside the dynamic range. LO values were concordant with plasma values, but HI values were considered uninterpretable. Capillary UA thresholds of 299 and 340 μmol/l gave the best results for detecting hyperuricemia (corresponding to routine plasma UA thresholds of 300 and 360 μmol/l, respectively). No significant confounding factor was found among those tested, except for hematocrit; however, this had a negligible influence on the assay reliability. When capillary and routine

  12. Puncturing the pipeline: Do technology companies alienate women in recruiting sessions?

    Science.gov (United States)

    Wynn, Alison T; Correll, Shelley J

    2018-02-01

    A 'chilly' environment limits women's advancement through the educational pipeline leading to jobs in science and technology. However, we know relatively little about the environment women encounter after making it through the educational pipeline. Do technology companies create environments that may dampen women's interest at the juncture when they are launching their careers? Using original observational data from 84 recruiting sessions hosted by technology companies at a prominent university on the US West Coast, we find that company representatives often engage in behaviors that are known to create a chilly environment for women. Through gender-imbalanced presenter roles, geek culture references, overt use of gender stereotypes, and other gendered speech and actions, representatives may puncture the pipeline, lessening the interest of women at the point of recruitment into technology careers.

  13. 40 CFR Table 14 to Subpart Xxxx of... - Continuous Compliance With the Emission Limitations for Puncture Sealant Application Affected...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Continuous Compliance With the Emission Limitations for Puncture Sealant Application Affected Sources 14 Table 14 to Subpart XXXX of Part 63... Hazardous Air Pollutants: Rubber Tire Manufacturing Pt. 63, Subpt. XXXX, Table 14 Table 14 to Subpart XXXX...

  14. Lathe Operator. Coordinator's Guide. Individualized Study Guide. General Metal Trades.

    Science.gov (United States)

    East Texas State Univ., Commerce. Occupational Curriculum Lab.

    This guide provides information to enable coordinators to direct learning activities for students using an individualized study guide on operating a lathe. The study material is designed for students enrolled in cooperative part-time training and employed, or desiring to be employed, as lathe operators. Contents include a sample progress chart,…

  15. Performance of an elliptically tapered neutron guide

    International Nuclear Information System (INIS)

    Muehlbauer, Sebastian; Stadlbauer, Martin; Boeni, Peter; Schanzer, Christan; Stahn, Jochen; Filges, Uwe

    2006-01-01

    Supermirror coated neutron guides are used at all modern neutron sources for transporting neutrons over large distances. In order to reduce the transmission losses due to multiple internal reflection of neutrons, ballistic neutron guides with linear tapering have been proposed and realized. However, these systems suffer from an inhomogeneous illumination of the sample. Moreover, the flux decreases significantly with increasing distance from the exit of the neutron guide. We propose using elliptically tapered guides that provide a more homogeneous phase space at the sample position as well as a focusing at the sample. Moreover, the design of the guide system is simplified because ellipses are simply defined by their long and short axes. In order to prove the concept we have manufactured a doubly focusing guide and investigated its properties with neutrons. The experiments show that the predicted gains using the program package McStas are realized. We discuss several applications of elliptic guides in various fields of neutron physics

  16. 40 CFR Table 13 to Subpart Xxxx of... - Minimum Data for Continuous Compliance With the Emission Limitations for Puncture Sealant...

    Science.gov (United States)

    2010-07-01

    ... XXXX of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Standards for Hazardous Air Pollutants: Rubber Tire Manufacturing Pt. 63, Subpt. XXXX, Table 13 Table 13 to Subpart XXXX of Part 63—Minimum Data for Continuous Compliance With the Emission Limitations for Puncture...

  17. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions

    Science.gov (United States)

    Alatawi, Abdullah; Beuvon, Frédéric; Grabar, Sophie; Leblanc, Sarah; Chaussade, Stanislas; Terris, Benoit; Barret, Maximilien

    2015-01-01

    Objectives Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using standard needles has a high diagnostic value in the evaluation of solid pancreatic masses. Fenestrated needles have been developed to improve the quality of EUS-guided tissue sampling by providing core biopsies (FNB). Methods Patients with solid pancreatic masses of >2 cm were prospectively included in our study and randomized to receive EUS sampling, using either a standard 22G FNA or a 22G Procore® FNB needle. The main study endpoint was the number of needle passes required to obtain a diagnosis in more than 90% of cases. Results We included 100 patients (male = 63, female = 37; mean age = 68.4 years) in our study. We found that 88% of the lesions were malignant, with a mean size of 32 mm. A sample adequate for diagnosis was obtained in more than 90% of cases after the second needle pass in the FNB group, versus the third needle pass in the FNA group. Slide cellularity and presence of tissue microfragments were significantly higher in the FNB group. Sensitivity for the diagnosis of malignancy was 88.4% versus 97.8% for the EUS-FNA and EUS-FNB group, respectively, while specificity for both techniques was 100%. No complications were recorded. Conclusions Although the accuracy of both needle types for proving malignancy was similar, a lower number of passes was required with the FNB needles to achieve the same contributive sample rate as with the FNA needles. FNB also improved the histopathological quality of specimens, suggesting an overall superiority of FNB sampling. PMID:26279842

  18. Adaptation of Hybrid FSO/RF Communication System Using Puncturing Technique

    Directory of Open Access Journals (Sweden)

    M. N. Khan

    2016-12-01

    Full Text Available Spectrum of radio frequency (RF communications is limited and expensive to install new applications. Free space optical (FSO communication is a viable technology which offers enormous bandwidth, license free installation, inexpensive deployment and error prone links. The FSO links degrade significantly due to the varying atmospheric and weather conditions (fog, cloud, snow, haze and combination of these. We propose a hybrid FSO/RF communication system which adapts the varying nature of atmosphere and weather. For the adaption of varying atmosphere and weather scenarios, we develop a novel optimization algorithm. The proposed algorithm is based on the well-known puncturing technique. We provide an extrinsic information transfer (EXIT chart for the binary and quaternary mapping scheme for the proposed communication system. We simulate the proposed algorithm for the hybrid communication system and analyze the system performance. The proposed algorithm is computationally less expensive and provide better performance gains over varying atmosphere and weather conditions. The algorithm is suitable for fast speed applications.

  19. Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results

    International Nuclear Information System (INIS)

    Bruners, Philipp; Penzkofer, Tobias; Nagel, Markus; Elfring, Robert; Schmitz-Rode, Thomas; Gronloh, Nina; Guenther, Rolf W.; Mahnken, Andreas H.

    2009-01-01

    An electromagnetic-based tracking and navigation system was evaluated for interventional radiology. The electromagnetic tracking system (CAPPA IRAD EMT, CASinnovations, Erlangen, Germany) was used for real-time monitoring of punctures of the lumbar facet joints and intervertebral disks in a spine phantom, three pig cadavers and three anaesthesized pigs. Therefore, pre-interventional computed tomography (CT) datasets were transferred to the navigation system and puncture trajectories were planned. A coaxial needle was advanced along the trajectories while the position of the needle tip was monitored in real time. After puncture tracts were marked with pieces of wire another CT examination was performed and distances between wires and anatomical targets were measured. Performing punctures of the facet joints mean needle positioning errors were 0.4 ± 0.8 mm in the spine phantom, 2.8 ± 2.1 mm ex vivo and 3.0 ± 2.0 mm in vivo with mean length of the puncture tract of 54.0 ± 10.4 mm (phantom), 51.6 ± 12.6 mm (ex vivo) and 50.9 ± 17.6 mm (in vivo). At first attempt, intervertebral discs were successfully punctured in 15/15 in the phantom study, in 12/15 in the ex-vivo study and 14/15 in the in-vivo study, respectively. Immobilization of the patient and optimal positioning of the field generator are essential to achieve a high accuracy of needle placement in a clinical CT setting. (orig.)

  20. Fluoroscopy-guided lumbar drainage of cerebrospinal fluid for patients in whom a blind beside approach is difficult

    Energy Technology Data Exchange (ETDEWEB)

    Chee, Choong Guen; Lee, Guen Young; Lee, Joon Woo; Lee, Eu Gene; Kang, Heung Sik [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-08-15

    To evaluate the rates of technical success, clinical success, and complications of fluoroscopy-guided lumbar cerebrospinal fluid drainage. This retrospective study was approved by the Institutional Review Board of our hospital, and informed consent was waived. Ninety-six procedures on 60 consecutive patients performed July 2008 to December 2013 were evaluated. The patients were referred for the fluoroscopy-guided procedure due to failed attempts at a bedside approach, a history of lumbar surgery, difficulty cooperating, or obesity. Fluoroscopy-guided lumbar drainage procedures were performed in the lateral decubitus position with a midline puncture of L3/4 in the interspinous space. The catheter tip was positioned at the T12/L1 level, and the catheter was visualized on contrast agent-aided fluoroscopy. A standard angiography system with a rotatable C-arm was used. The definitions of technical success, clinical success, and complications were defined prior to the study. The technical and clinical success rates were 99.0% (95/96) and 89.6% (86/96), respectively. The mean hospital stay for an external lumbar drain was 4.84 days. Nine cases of minor complications and eight major complications were observed, including seven cases of meningitis, and one retained catheter requiring surgical removal. Fluoroscopy-guided external lumbar drainage is a technically reliable procedure in difficult patients with failed attempts at a bedside procedure, history of lumbar surgery, difficulties in cooperation, or obesity.

  1. [Value of ultrasonically-guided liver puncture biopsy in the diagnosis of primary liver cancer. Apropos of 84 cases].

    Science.gov (United States)

    Peghini, M; Eynard, J P; Vergne, R; Seurat, P; Barabe, P; Aubry, P; Diallo, A; Gueye, P M

    1987-01-01

    Ultrasonographicaly guided fine needle aspiration of liver was performed in 84 patients having a confirmed HCC. This technics utilizes a CHIBA type fine needle, after blood coagulation tests have been checked. Out of 84 fine needle aspirations performed: 64 were positive (76,2%), 9 negative (10,7%), 11 (13,19%) were questionable (6) or nonanalysable (5). It is ascertained that the sensibility of this technics is over 75%. It should be possible to improve it by repeating such an exam in previously negative patients. The causes of failure are discussed. Tolerance of the technics is good. It is attraumatic, and of very easily performance. No accident, no mishap was noted.

  2. Preoperative Direct Puncture Embolization of Advanced Juvenile Nasopharyngeal Angiofibroma in Combination with Transarterial Embolization: An Analysis of 22 Consecutive Patients

    Energy Technology Data Exchange (ETDEWEB)

    Lv Mingming, E-mail: lvmingming001@163.com; Fan, Xin-dong, E-mail: fanxindong@yahoo.com.cn [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ninth People' s Hospital (China); Su Lixin, E-mail: sulixin1975@126.com [Shanghai Jiao Tong University School of Medicine, Department of Oral and Maxillofacial Surgery, Ninth People' s Hospital (China); Chen Dong, E-mail: chenjsun@public8.sta.net.cn [Shanghai Jiao Tong University School of Medicine, Department of Otolaryngology, Ninth People' s Hospital (China)

    2013-02-15

    ObjectiveThis study was designed to evaluate the clinical application of preoperative auxiliary embolization for juvenile nasopharyngeal angiofibroma (JNA) by direct puncture embolization (DPE) of the tumor in combination with transarterial embolization (TAE). The study included 22 patients. An 18-gauge needle was used to puncture directly into the tumor, and 20-25 % N-butyl cyanoacrylate was injected under the guidance of fluoroscopy after confirming the placement of the needle into the JNA and no leaking into the surrounding tissue. Tumors were obstructed later via TAE. The supplying arteries of JNA were from branches of the internal carotid and external carotid arteries. Control angiography showed the obliteration of contrast stain in the entire tumor mass and the distal supplying arteries disappeared after DPE in combination with TAE. Surgical resection was performed within 4 days after embolization and none of the patients required blood transfusion. The use of DPE in combination with TAE was a safe, feasible, and efficacious method. It can devascularize effectively the JNAs and reduce intraoperative bleeding when JNAs are extirpated.

  3. Preoperative Direct Puncture Embolization of Advanced Juvenile Nasopharyngeal Angiofibroma in Combination with Transarterial Embolization: An Analysis of 22 Consecutive Patients

    International Nuclear Information System (INIS)

    Lv Mingming; Fan, Xin-dong; Su Lixin; Chen Dong

    2013-01-01

    ObjectiveThis study was designed to evaluate the clinical application of preoperative auxiliary embolization for juvenile nasopharyngeal angiofibroma (JNA) by direct puncture embolization (DPE) of the tumor in combination with transarterial embolization (TAE). The study included 22 patients. An 18-gauge needle was used to puncture directly into the tumor, and 20–25 % N-butyl cyanoacrylate was injected under the guidance of fluoroscopy after confirming the placement of the needle into the JNA and no leaking into the surrounding tissue. Tumors were obstructed later via TAE. The supplying arteries of JNA were from branches of the internal carotid and external carotid arteries. Control angiography showed the obliteration of contrast stain in the entire tumor mass and the distal supplying arteries disappeared after DPE in combination with TAE. Surgical resection was performed within 4 days after embolization and none of the patients required blood transfusion. The use of DPE in combination with TAE was a safe, feasible, and efficacious method. It can devascularize effectively the JNAs and reduce intraoperative bleeding when JNAs are extirpated.

  4. Incremental Validity Analyses of the Violence Risk Appraisal Guide and the Psychopathy Checklist: Screening Version in a Civil Psychiatric Sample

    Science.gov (United States)

    Edens, John F.; Skeem, Jennifer L.; Douglas, Kevin S.

    2006-01-01

    This study compares two instruments frequently used to assess risk for violence, the Violence Risk Appraisal Guide (VRAG) and the Psychopathy Checklist: Screening Version (PCL:SV), in a large sample of civil psychiatric patients. Despite a strong bivariate relationship with community violence, the VRAG could not improve on the predictive validity…

  5. Opinion and Special Articles: Stress when performing the first lumbar puncture may compromise patient safety.

    Science.gov (United States)

    Henriksen, Mikael Johannes Vuokko; Wienecke, Troels; Kristiansen, Jesper; Park, Yoon Soo; Ringsted, Charlotte; Konge, Lars

    2018-05-22

    To quantify physician stress levels when performing lumbar puncture (LP) and explore operator stress effect on patient outcomes. This was a cross-sectional, multicenter study. Novices, intermediates, and experts in performing LP were recruited from 4 departments of neurology and emergency medicine. Stress was measured before and during performance of the LP using cognitive appraisal (CA), State-Trait Anxiety Inventory-Short (STAI-S) questionnaire, and the heart rate variability measure low frequency/high frequency index (LF/HF ratio). Patient-related outcomes were pain, confidence in the operator, and postdural puncture headache (PDPH). Forty-six physicians were included in the study: 22 novices, 12 intermediates, and 12 experts. Novices had the highest stress level and experts the lowest measured by cognitive appraisal and STAI-S before and during LP performance ( p < 0.001 for all comparisons). Novices had the highest sympathetic tonus indicated by the highest LF/HF ratio before ( p = 0.004) and during ( p = 0.056) LP performance. Physician stress level was not significantly related to patients' pain. However, there was a significant relationship between STAI-S during the procedure and patient confidence in the operator (regression coefficient = -0.034, p = 0.008). High physician heart rate during the procedure significantly increased the odds of PDPH (odds ratio = 1.17, p = 0.036). Novice stress levels were high before and during performance of LP. Stress was significantly related to patient confidence in the operator and risk of PDPH. Simulation-based training should be considered to reduce novice residents' stress levels and increase patient safety. © 2018 American Academy of Neurology.

  6. Image-guided procedures in brain biopsy.

    Science.gov (United States)

    Fujita, K; Yanaka, K; Meguro, K; Narushima, K; Iguchi, M; Nakai, Y; Nose, T

    1999-07-01

    Image-guided procedures, such as computed tomography (CT)-guided stereotactic and ultrasound-guided methods, can assist neurosurgeons in localizing the relevant pathology. The characteristics of image-guided procedures are important for their appropriate use, especially in brain biopsy. This study reviewed the results of various image-guided brain biopsies to ascertain the advantages and disadvantages. Brain biopsies assisted by CT-guided stereotactic, ultrasound-guided, Neuronavigator-guided, and the combination of ultrasound and Neuronavigator-guided procedures were carried out in seven, eight, one, and three patients, respectively. Four patients underwent open biopsy without a guiding system. Twenty of 23 patients had a satisfactory diagnosis after the initial biopsy. Three patients failed to have a definitive diagnosis after the initial procedure, one due to insufficient volume sampling after CT-guided procedure, and two due to localization failure by ultrasound because the lesions were nonechogenic. All patients who underwent biopsy using the combination of ultrasound and Neuronavigator-guided methods had a satisfactory result. The CT-guided procedure provided an efficient method of approaching any intracranial target and was appropriate for the diagnosis of hypodense lesions, but tissue sampling was sometimes not sufficient to achieve a satisfactory diagnosis. The ultrasound-guided procedure was suitable for the investigation of hyperdense lesions, but was difficult to localize nonechogenic lesions. The combination of ultrasound and Neuronavigator methods improved the diagnostic accuracy even in nonechogenic lesions such as malignant lymphoma. Therefore, it is essential to choose the most appropriate guiding method for brain biopsy according to the radiological nature of the lesions.

  7. The contribution of cell blocks in the diagnosis of mediastinal masses and hilar adenopathy samples from echobronchoscopy.

    Science.gov (United States)

    Lourido-Cebreiro, Tamara; Leiro-Fernández, Virginia; Tardio-Baiges, Antoni; Botana-Rial, Maribel; Núñez-Delgado, Manuel; Álvarez-Martín, M Jesús; Fernández-Villar, Alberto

    2014-07-01

    Cell block material from puncture can be obtained with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in many cases. The aim of this study was to analyse the value of additional information from cell blocks obtained with EBUS-TBNA samples from mediastinal and hilar lymph nodes and masses. Review of pathology reports with a specific diagnosis obtained from EBUS-TBNA samples of mediastinal or hilar lesions, prospectively obtained over a two-year period. The generation of cell blocks from cytology needle samples, the contribution to morphological diagnosis, and the possible use of samples for immunohistochemistry were analysed. One hundred and twenty-nine samples corresponding to 110 patients were reviewed. The diagnosis was lung cancer in 81% of cases, extrapulmonary carcinoma in 10%, sarcoidosis in 4%, lymphoma in 2.7%, and tuberculosis in 0.9%. Cell blocks could be obtained in 72% of cases. Immunohistochemistry studies on the cell blocks were significantly easier to perform than on conventional smears (52.6% vs. 14%, P<.0001). In 4cases, the cell block provided an exclusive morphological diagnosis (3sarcoidosis and one metastasis from prostatic carcinoma) and in 3carcinomas, subtype and origin could be identified. Exclusive diagnoses from the cell block were significantly more frequent in benign disease than in malignant disease (25% vs 0.9%, P=.002). Cell blocks were obtained from 72% of EBUS-TBNA diagnostic procedures. The main contributions of cell blocks to pathology examinations were the possibility of carrying out immunohistochemical staining for the better classification of neoplasms, especially extrapulmonary metastatic tumours, and the improved diagnosis of benign lesions. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  8. A randomised crossover study to compare the cross-sectional and longitudinal approaches to ultrasound-guided peripheral venepuncture in a model.

    Science.gov (United States)

    Griffiths, James; Carnegie, Amadeus; Kendall, Richard; Madan, Rajeev

    2017-12-01

    Ultrasound-guided peripheral intravenous access may present an alternative to central or intraosseous access in patients with difficult peripheral veins. Using venepuncture of a phantom model as a proxy, we investigated whether novice ultrasound users should adopt a cross-sectional or longitudinal approach when learning to access peripheral veins under ultrasound guidance. This result would inform the development of a structured training method for this procedure. We conducted a randomised controlled trial of 30 medical students. Subjects received 35 min of training, then attempted to aspirate 1 ml of synthetic blood from a deep vein in a training model under ultrasound guidance. Subjects attempted both the cross-sectional and longitudinal approaches. Group 1 used cross-sectional first, followed by longitudinal. Group 2 used longitudinal first, then cross-sectional. We measured the time from first puncture of the model's skin to aspiration of fluid, and the number of attempts required. Subjects also reported difficulty ratings for each approach. Paired sample t-tests were used for statistical analysis. The mean number of attempts was 1.13 using the cross-sectional approach, compared with 1.30 using the longitudinal approach (p = 0.17). Mean time to aspiration of fluid was 45.1 s using the cross-sectional approach and 52.8 s using the longitudinal approach (p = 0.43). The mean difficulty score out of 10 was 3.97 for the cross-sectional approach and 3.93 for the longitudinal approach (p = 0.95). We found no significant difference in effectiveness between the cross-sectional and longitudinal approaches to ultrasound-guided venepuncture when performed on a model. We believe that both approaches should be included when teaching ultrasound-guided peripheral vascular access. To confirm which approach would be best in clinical practice, we advocate future testing of both approaches on patients.

  9. Treatment with 24 h-delayed normo- and hyperbaric oxygenation in severe sepsis induced by cecal ligation and puncture in rats

    DEFF Research Database (Denmark)

    Bærnthsen, Nina Falcon; Hansen, Marco Bo; Wahl, Anna Mygind

    2017-01-01

    uncertain. We investigated the effects of 24 h delayed normobaric oxygen (NBO2) and HBO2treatment on the endogenous production of the inflammatory markers interleukin (IL)-6, tumor necrosis factor (TNF)-α and IL-10, and on mortality in rats with cecal ligation and puncture (CLP) induced sepsis. Method...

  10. Sampling in forests for radionuclide analysis. General and practical guidance

    Energy Technology Data Exchange (ETDEWEB)

    Aro, Lasse (Finnish Forest Research Inst. (METLA) (Finland)); Plamboeck, Agneta H. (Swedish Defence Research Agency (FOI) (Sweden)); Rantavaara, Aino; Vetikko, Virve (Radiation and Nuclear Safety Authority (STUK) (Finland)); Straalberg, Elisabeth (Inst. Energy Technology (IFE) (Norway))

    2009-01-15

    The NKS project FOREST was established to prepare a guide for sampling in forest ecosystems for radionuclide analysis. The aim of this guide is to improve the reliability of datasets generated in future studies by promoting the use of consistent, recommended practices, thorough documentation of field sampling regimes and robust preparation of samples from the forest ecosystem. The guide covers general aims of sampling, the description of major compartments of the forest ecosystem and outlines key factors to consider when planning sampling campaigns for radioecological field studies in forests. Recommended and known sampling methods for various sample types are also compiled and presented. The guide focuses on sampling practices that are applicable in various types of boreal forests, robust descriptions of sampling sites, and documentation of the origin and details of individual samples. The guide is intended for scientists, students, forestry experts and technicians who appreciate the need to use sound sampling procedures in forest radioecological projects. The guide will hopefully encourage readers to participate in field studies and sampling campaigns, using robust techniques, thereby fostering competence in sampling. (au)

  11. Sampling in forests for radionuclide analysis. General and practical guidance

    International Nuclear Information System (INIS)

    Aro, Lasse; Plamboeck, Agneta H.; Rantavaara, Aino; Vetikko, Virve; Straelberg, Elisabeth

    2009-01-01

    The NKS project FOREST was established to prepare a guide for sampling in forest ecosystems for radionuclide analysis. The aim of this guide is to improve the reliability of datasets generated in future studies by promoting the use of consistent, recommended practices, thorough documentation of field sampling regimes and robust preparation of samples from the forest ecosystem. The guide covers general aims of sampling, the description of major compartments of the forest ecosystem and outlines key factors to consider when planning sampling campaigns for radioecological field studies in forests. Recommended and known sampling methods for various sample types are also compiled and presented. The guide focuses on sampling practices that are applicable in various types of boreal forests, robust descriptions of sampling sites, and documentation of the origin and details of individual samples. The guide is intended for scientists, students, forestry experts and technicians who appreciate the need to use sound sampling procedures in forest radioecological projects. The guide will hopefully encourage readers to participate in field studies and sampling campaigns, using robust techniques, thereby fostering competence in sampling. (au)

  12. Percutaneous Placement of Central Venous Catheters: Comparing the Anatomical Landmark Method with the Radiologically Guided Technique for Central Venous Catheterization Through the Internal Jugular Vein in Emergent Hemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Koroglu, M.; Demir, M.; Koroglu, B.K.; Sezer, M.T.; Akhan, O.; Yildiz, H.; Yavuz, L.; Baykal, B.; Oyar, O. [Suleyman Demirel Univ., Isparta (Turkey). Depts. of Radiology, Internal Medicine and Anesthesiology

    2006-02-15

    Purpose: To compare the success and immediate complication rates of the anatomical landmark method (group 1) and the radiologically (combined real-time ultrasound and fluoroscopy) guided technique (group 2) in the placement of central venous catheters in emergent hemodialysis patients. Material and Methods: The study was performed prospectively in a randomized manner. The success and immediate complication rates of radiologically guided placement of central venous access catheters through the internal jugular vein (n = 40) were compared with those of the anatomical landmark method (n 40). The success of placement, the complications, the number of passes required, and whether a single or double-wall puncture occurred were also noted and compared. Results: The groups were comparable in age and sex. The indication for catheter placement was hemodialysis access in all patients. Catheter placement was successful in all patients in group 2 and unsuccessful in 1 (2.5%) patient in group 1. All catheters functioned adequately and immediately after the placement (0% initial failure rate) in group 2, but 3 catheters (7.5% initial failure rate) were non-functional just after placement in group 1. The total number of needle passes, double venous wall puncture, and complication rate were significantly lower in group 2. Conclusion: Percutaneous central venous catheterization via the internal jugular vein can be performed by interventional radiologists with better technical success rates and lower immediate complications. In conclusion, central venous catheterization for emergent dialysis should be performed under both real-time ultrasound and fluoroscopic guidance.

  13. Direct stent puncture technique for intraluminal stent recanalization in the superficial femoral and popliteal arteries in-stent occlusion: Outcomes from a prospective clinical analysis of diabetics with critical limb ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Palena, Luis Mariano, E-mail: marianopalena@hotmail.com; Manzi, Marco

    2013-07-15

    Purpose: To evaluate the efficacy and safety of “Direct Stent Puncture” technique for intraluminal stent recanalization in the femoro-popliteal segments. Methods and Materials: A cohort of diabetics who had symptomatic in-stent occlusion of the superficial femoral or popliteal arteries underwent endovascular recanalization. After antegrade failure, direct stent puncture technique was performed. The primary end-point was to efficacy assessment, intended as technical success and clinical improvement. The secondary end-point was safety assessment, intended as free of complication rate. Results: Fifty-four patients (37 men; 73.6 ± 8.5 years) underwent direct stent puncture technique, after several unsuccessful antegrade attempts to cross the occluded stent. Technical success for intraluminal stent recanalization was achieved in 53/54 (98.2%) of cases and failed in 1/54 (1.8%). Clinical improvement was obtained in 51/54 (94.4%) of cases, with regression of the clinical symptoms and improvement of the TcPO{sub 2}, from 3 ± 18 mmHg to 43 ± 11 mmHg after 15 days (p < 0.001). Free of complications rate was 92.5%. In 2/54 (3.7%) of cases distal embolization occurred, in 1/54 (1.9%) case a sudden vessel thrombosis was diagnosed after 12 hours and in 1/54 (1.9%) case hematoma at the stent puncture site was observed. Conclusions: Direct Stent Puncture technique is an efficacy and safety option for intraluminal stent recanalization in the femoro-popliteal segment in-stent occlusion.

  14. Advanced geometries for ballistic neutron guides

    International Nuclear Information System (INIS)

    Schanzer, Christian; Boeni, Peter; Filges, Uwe; Hils, Thomas

    2004-01-01

    Sophisticated neutron guide systems take advantage of supermirrors being used to increase the neutron flux. However, the finite reflectivity of supermirrors becomes a major loss mechanism when many reflections occur, e.g. in long neutron guides and for long wavelengths. In order to reduce the number of reflections, ballistic neutron guides have been proposed. Usually linear tapered sections are used to enlarge the cross-section and finally, focus the beam to the sample. The disadvantages of linear tapering are (i) an inhomogeneous phase space at the sample position and (ii) a decreasing flux with increasing distance from the exit of the guide. We investigate the properties of parabolic and elliptic tapering for ballistic neutron guides, using the Monte Carlo program McStas with a new guide component dedicated for such geometries. We show that the maximum flux can indeed be shifted away from the exit of the guide. In addition we explore the possibilities of parabolic and elliptic geometries to create point like sources for dedicated experimental demands

  15. Freehand direct arthrography of the shoulder using near real-time guidance in an open 1.0-T MRI scanner

    Energy Technology Data Exchange (ETDEWEB)

    Wybranski, Christian [University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, Cologne (Germany); Adamchic, Ilya; Ricke, Jens; Fischbach, Frank; Fischbach, Katharina [Otto-von-Guericke University Medical School, Department of Radiology and Nuclear Medicine, Magdeburg (Germany); Roehl, Friedrich-Wilhelm [Otto-von-Guericke University Medical School, Institute of Biometry and Medical Informatics, Magdeburg (Germany)

    2017-01-15

    To assess the technical success and duration of magnetic resonance imaging (MRI)-guided freehand direct shoulder arthrography (FDSA) with near real-time imaging implemented in a routine shoulder MRI examination on an open 1.0-T MRI scanner, and to assess the learning curve of residents new to this technique. An experienced MRI interventionalist (the expert) performed 125 MRI-guided FDSA procedures, and 75 patients were treated by one of three residents without previous experience in MRI-guided FDSA. Technical success rate and duration of MRI-guided FDSA of the expert and the residents were compared. The residents' learning curves were assessed. The occurrence of extra-articular deposition and leakage of contrast media from the puncture site and the subsequent impairment of image interpretation were retrospectively analyzed. Overall technical success was 97.5 %. The expert needed overall fewer puncture needle readjustments and was faster at puncture needle positioning (p < 0.01). The learning curve of the residents, however, was steep. They leveled with the performance of the expert after ∼ 15 interventions. With a minimal amount of training all steps of MRI-guided FDSA can be performed in ≤10 min. Magnetic resonance-guided FDSA in an open 1.0-T MRI scanner can be performed with high technical success in a reasonably short amount of time. Only a short learning curve is necessary to achieve expert level. (orig.)

  16. Under X-ray guidance stent implantation through retrograde popliteal artery puncturing for the treatment of superficial femoral artery occlusion: the initial results in nine cases

    International Nuclear Information System (INIS)

    He Xu; Gu Jianping; Lou Wensheng; Chen Liang; Chen Guoping; Su Haobo; Song Jinhua; Wang Tao; Xu Ke

    2011-01-01

    Objective: To discuss the application of retrograde popliteal artery puncturing under X-ray guidance in the interventional therapy for superficial femoral artery occlusion. Methods: Retrograde popliteal artery puncturing under X-ray guidance was carried out in nine patients with long-segment occlusion of superficial femoral artery as antegrade recanalization via femoral artery approach had failed in them. After retrograde route was successfully established, the balloon dilation and subsequent stent placement for occluded vessel were performed. Results: The technical success was obtained in all patients. The occluded superficial femoral arteries were reopened and the symptoms of intermittent claudication disappeared. No serious complications such as injuries of adjacent nerves or vessels occurred. The ankle-brachial index (ABI) increased from preoperative (0.38±0.13) to postoperative (0.92±0.11) with the difference being statistically significant (P<0.01). A follow-up period lasting for 2-16 months was conducted. Eleven months after the treatment, intermittent claudication recurred in one case, and CT angiography showed that the distal part of the stent was narrowed. The symptoms were improved after percutaneous transcatheter angioplasty was performed again. Conclusion: Retrograde popliteal artery puncturing under X-ray guidance is an effective and safe technique for the treatment of superficial femoral artery long-segment occlusion with stent placement, especially for patients in whom antegrade recanalization via femoral artery approach fails. (authors)

  17. Ultrasound-guided greater auricular nerve block as sole anesthetic for ear surgery

    Directory of Open Access Journals (Sweden)

    Michael K. Ritchie

    2016-05-01

    Full Text Available A greater auricular nerve (GAN block was used as the sole anesthetic for facial surgery in an 80-year-old male patient with multiple comorbidities which would have made general anesthesia challenging. The GAN provides sensation to the ear, mastoid process, parotid gland, and angle of the mandible. In addition to anesthesia for operating room surgery, the GAN block can be used for outpatient or emergency department procedures without the need for a separate anesthesia team. Although this nerve block has been performed using landmark-based techniques, the ultrasoundguided version offers several potential advantages. These advantages include increased reliability of the nerve block, as well as prevention of inadvertent vascular puncture or blockade of the phrenic nerve, brachial plexus, or deep cervical plexus. The increasing access to ultrasound technology for medical care providers outside the operating room makes this ultrasound guided block an increasingly viable alternative.

  18. Giving Students Control over Their Learning; from Self-guided Museum Visits and Field Trips to Using Scanning Technology to Link Content to Earth Samples

    Science.gov (United States)

    Kirkby, K. C.; Phipps, M.

    2011-12-01

    While it may seem counterintuitive, sometimes stepping back is one of the more effective pedagogical approaches instructors can make. On museum visits, an instructor's presence fundamentally alters students' experiences and can curtail student learning by limiting questions or discouraging students from exploring their own interests. Students often rely on the instructor and become passive observers, rather than engaged learners. As an alternative to instructor-led visits, self-guided student explorations of museum exhibits proved to be both popular and pedagogically effective. On pre-instruction and post-instruction surveys, these ungraded, self-guided explorations match or exceed the efficacy of traditional graded lab instruction and completely eclipse gains normally achieved by traditional lecture instruction. In addition, these explorations achieve the remarkable goal of integrating undergraduate earth science instruction into students' social lives. Based on the success of the self-guided museum explorations, this fall saw the debut of an attempt to expand this concept to field experiences. A self-guided student field exploration of Saint Anthony Falls focuses on the intersections of geological processes with human history. Students explore the waterfalls' evolution, its early interpretation by 18th and 19th century Dakota and Euro-America societies, and its subsequent social and economic impacts on Upper Midwest societies. Self-guided explorations allow students to explore field settings on their own or with friends and family in a more relaxed manner. At the same time, these explorations give students control over, and responsibility for, their own learning - a powerful pedagogical approach. Student control over their learning is also the goal of an initiative to use scanning technologies, such as linear bar codes, 2D barcodes and radio-frequency identification (RFID), to revolutionize sample identification and study. Scanning technology allows students to

  19. Impact of femoral artery puncture using digital subtraction angiography and road mapping on vascular and bleeding complications after transfemoral transcatheter aortic valve implantation.

    Science.gov (United States)

    El-Mawardy, Mohamed; Schwarz, Bettina; Landt, Martin; Sulimov, Dmitriy; Kebernik, Julia; Allali, Abdelhakim; Becker, Bjoern; Toelg, Ralph; Richardt, Gert; Abdel-Wahab, Mohamed

    2017-01-20

    The use of large-diameter sheaths carries the risk of significant vascular and bleeding complications after transfemoral transcatheter aortic valve implantation (TAVI). In this analysis, we sought to assess the impact of a modified femoral artery puncture technique using digital subtraction angiography (DSA) and road mapping during transfemoral TAVI on periprocedural vascular and bleeding events. This is a retrospective analysis of transfemoral TAVI patients included in a prospective institutional database. The modified femoral artery puncture technique using DSA-derived road mapping guidance was introduced in October 2012. Before the introduction of this technique, vascular puncture was acquired based on an integration of angiographic data, the bony iliofemoral landmarks and a radiopaque object. Consecutive patients who underwent TAVI with the road mapping technique (RM group, n=160) were compared with consecutive patients who underwent TAVI without road mapping (control group, n=160) prior to its introduction. A standardised strategy of periprocedural anticoagulation was adopted in both groups as well as the use of a single suture-based closure device. All endpoints were defined according to the VARC-2 criteria for event definition. The mean age in the RM group was 80±7.7 years compared to 81±5.9 years in the control group (p=0.19), and females were equally distributed between both groups (63.1% vs. 58.1%, p=0.36). The baseline logistic EuroSCORE was 20.7±14.4% vs. 24.9±15.2% in the RM and control group, respectively (p=0.01). Notably, sheath size was significantly larger in the RM compared to the control group due to the more frequent use of the 20 Fr sheath (23.8% vs. 1.8%, proad map group but did not reach statistical significance (8.1% vs. 13.8%, p=0.1). Other forms of vascular and bleeding complications as well as all-cause mortality were comparable in both groups. A modified femoral artery puncture technique using DSA and road mapping was associated

  20. Juvenile nasopharyngeal angiofibroma with skull base invasion : intratumoral direct puncture embolization

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hye Young; Kim, Sun Yong; Suh, Jung Ho; Park, Kee Hyun [Ajou Univ., Suwon (Korea, Republic of). Coll. of Medicine

    1998-04-01

    The purpose of this study is to demonstrate the utility and efficacy of percutaneous direct glue embolization for juvenile nasopharyngeal angiofibromas with skull base invasion. In nine cases of juvenile nasopharyngeal angiofibromas with invasion of the skull base, embolization under general anethesia was performed. Using an 18G spinal needle, direct puncture were made via the transnasal or mandibular sciatic notch. A glue-lipiodol mixture (1:1 -1:3) was injected slowly for 15 to 30 seconds under fluoroscopic control; the number of post-embolization angiography and the distribution of embolic materials was assessed on CT within 1-3 days. The mass was surgically removed 3 to 7 days after embolization. Direct glue embolization of juvenile angiofibroma with skull base invasion appears to be a simple and safe procedure. The technique could be used for other hypervascular lesions in the base of the skull or parapharyngeal space. (author). 19 refs., 1 tab., 2 figs.

  1. Juvenile nasopharyngeal angiofibroma with skull base invasion : intratumoral direct puncture embolization

    International Nuclear Information System (INIS)

    Shin, Hye Young; Kim, Sun Yong; Suh, Jung Ho; Park, Kee Hyun

    1998-01-01

    The purpose of this study is to demonstrate the utility and efficacy of percutaneous direct glue embolization for juvenile nasopharyngeal angiofibromas with skull base invasion. In nine cases of juvenile nasopharyngeal angiofibromas with invasion of the skull base, embolization under general anethesia was performed. Using an 18G spinal needle, direct puncture were made via the transnasal or mandibular sciatic notch. A glue-lipiodol mixture (1:1 -1:3) was injected slowly for 15 to 30 seconds under fluoroscopic control; the number of post-embolization angiography and the distribution of embolic materials was assessed on CT within 1-3 days. The mass was surgically removed 3 to 7 days after embolization. Direct glue embolization of juvenile angiofibroma with skull base invasion appears to be a simple and safe procedure. The technique could be used for other hypervascular lesions in the base of the skull or parapharyngeal space. (author). 19 refs., 1 tab., 2 figs

  2. Ultrasound-guided percutaneous cholecysto-cholangiography for the exclusion of biliary atresia in infants

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Kyung Min; Ryeom, Hun Kyu; Choe, Byung Ho; Kim, Kap Cheol; Kim, Jong Yeol; Lee, Jong Min; Kim, Hye Jeong; Lee, Hee Jung [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2006-08-15

    The aim of this study is to determine the feasibility and effectiveness of performing an ultrasound-guided percutaneous cholecysto-cholangiogram (PCC) for excluding biliary atresia as the cause of neonatal jaundice. Between Oct. 2003 and Feb. 2005, six ultrasound-guided PCC procedures were performed to five jaundiced infants (4 females and 1 male; mean age: 60 days old) for whom possibility of biliary atresia could not be ruled out by the DISIDA scan as the cause of their neonatal jaundice. Gallbladder puncture was performed under ultrasound guidance with a 23-gauge needle. Contrast material injection during fluoroscopic examination was performed after dilatation of the gallbladder lumen with normal saline under ultrasound guidance. The criteria used for excluding biliary atresia were complete visualization of the extrahepatic biliary trees and/or contrast excretion into the duodenum. The complications and final diagnosis was assessed according to the clinical and laboratory findings. The procedures were successful in all the patients without any complication. Biliary atresia could be ruled out in all the patients. The final diagnosis was neonatal cytomegalovirus hepatitis in two patients, total parenteral nutrition-associated cholestasis in two patients, and combined cytomegalovirus hepatitis and total parenteral nutrition-associated cholestasis in one patient. Ultrasound-guided PCC is a feasible and effective method for the early definitive exclusion of biliary atresia as the cause of neonatal jaundice. By the technique of injecting normal saline before contrast injection, PCC can be done even in a totally collapsed or very small gallbladder.

  3. Ultrasound-guided percutaneous cholecysto-cholangiography for the exclusion of biliary atresia in infants

    International Nuclear Information System (INIS)

    Shin, Kyung Min; Ryeom, Hun Kyu; Choe, Byung Ho; Kim, Kap Cheol; Kim, Jong Yeol; Lee, Jong Min; Kim, Hye Jeong; Lee, Hee Jung

    2006-01-01

    The aim of this study is to determine the feasibility and effectiveness of performing an ultrasound-guided percutaneous cholecysto-cholangiogram (PCC) for excluding biliary atresia as the cause of neonatal jaundice. Between Oct. 2003 and Feb. 2005, six ultrasound-guided PCC procedures were performed to five jaundiced infants (4 females and 1 male; mean age: 60 days old) for whom possibility of biliary atresia could not be ruled out by the DISIDA scan as the cause of their neonatal jaundice. Gallbladder puncture was performed under ultrasound guidance with a 23-gauge needle. Contrast material injection during fluoroscopic examination was performed after dilatation of the gallbladder lumen with normal saline under ultrasound guidance. The criteria used for excluding biliary atresia were complete visualization of the extrahepatic biliary trees and/or contrast excretion into the duodenum. The complications and final diagnosis was assessed according to the clinical and laboratory findings. The procedures were successful in all the patients without any complication. Biliary atresia could be ruled out in all the patients. The final diagnosis was neonatal cytomegalovirus hepatitis in two patients, total parenteral nutrition-associated cholestasis in two patients, and combined cytomegalovirus hepatitis and total parenteral nutrition-associated cholestasis in one patient. Ultrasound-guided PCC is a feasible and effective method for the early definitive exclusion of biliary atresia as the cause of neonatal jaundice. By the technique of injecting normal saline before contrast injection, PCC can be done even in a totally collapsed or very small gallbladder

  4. Modelo simulador para treinamento de punção transpedicular em vertebroplastia percutânea Manikin-type training simulator model for transpedicular puncture in percutaneous vertebroplasty

    Directory of Open Access Journals (Sweden)

    Nitamar Abdala

    2007-08-01

    Full Text Available OBJETIVO: Desenvolver e testar a similaridade de modelo de coluna lombar tipo manequim para treinamento de punção transpedicular em vertebroplastia percutânea. MATERIAIS E MÉTODOS: Foram confeccionadas 30 vértebras lombares à base, principalmente, de metacrilato, gesso e etil-vinil-acetato, a partir de molde de borracha baseado em vértebra humana. Os discos intervertebrais foram feitos com silicone para que houvesse similaridade anatômica e fusão de cinco vértebras. O segmento da coluna foi acondicionado no interior de um manequim coberto por tela de etil-vinil-acetato para que não fosse possível a visualização direta. Foi realizado curso teórico para seis especializandos de radiologia e neurorradiologia, que testaram o modelo para vários parâmetros de similaridade com a realidade, realizando 30 punções transpediculares, em três sessões de dez procedimentos por dia, com intervalo de uma semana entre cada sessão. RESULTADOS: Cada aluno realizou 30 punções transpediculares, porém oito punções foram desconsideradas, pois se observaram problemas de manufatura dos modelos durante estes procedimentos. Após a realização das punções, todos os participantes preencheram o formulário de similaridade, com 100% de respostas positivas em relação à similaridade do modelo. CONCLUSÃO: Foi possível o desenvolvimento de modelo para punção transpedicular com similaridade satisfatória com o ser humano, configurando um instrumento de treinamento de vertebroplastia.OBJECTIVE: To develop and test a model of the human lumbar vertebra for training transpedicular puncture in percutaneous vertebroplasty. MATERIALS AND METHODS: Thirty lumbar vertebra models were constructed from methacrylate, plaster and ethyl-vinyl-acetate, using a rubber mold of human vertebrae. The intervertebral discs were made of silicone to provide anatomical similarity and fusion of five vertebrae. This model of spinal column segment was positioned within a

  5. The role of invasive sonography in the differential diagnosis and treatment of intraabdominal fluid collections.

    Science.gov (United States)

    Regöly-Mérei, J; Ihász, M; Szeberin, Z; Záborszky, A

    Sixty-nine ultrasound-guided interventions (23 punctures and 46 drainages) were performed on 51 patients with the suspicion of intraabdominal abscess or another type of fluid collection in a prospective-controlled study. Of the procedures, 58.8% were carried out following surgery, while in 41.2% the indication were not related to prior surgical intervention. Repeated procedures were done in 10 patients. In the group of punctures the procedure was therapeutic in 3 cases and diagnostic in 16 patients. The drainage was technically successful in 92.7%. The drain was displaced or blocked in 27% (n = 10), but reinterventions were necessary in only 5 cases for this reason. The total number of redrainages was 18.9%. The percutaneous (pc) drainage was insufficient in 8 patients (21.6%), all these patients were operated on. 62.2% of the patients recovered after pc drainage, 13.5% following redrainage (total 75.5%). In 8.1% of the cases after pc drainage and in 5.4% after pc redrainage open surgery became necessary. There was only one complication due to the procedure. Seven patients (14.3%) died of the disease which indicated the procedure. There were no fatal outcomes on the account of the intervention. Ultrasound-guided puncture is a suitable method to indicate or contraindicate open surgery in the case of intraabdominal fluid collection. The diagnostic puncture may be followed by sonographically guided drainage or in selected cases by therapeutic puncture, but if the pc drainage is insufficient, open surgery should be performed in time.

  6. Steerable antegrade stenting: a new trick of the trade

    Directory of Open Access Journals (Sweden)

    Udo Nagele

    2007-06-01

    Full Text Available INTRODUCTION: Whereas a retrograde attempt to insert an indwelling stent is performed in lithotomy position, usually renal access is gained in a prone position. To overcome the time loss of patient repositioning, a renal puncture can be performed in a modified lithotomy position with torqued truncus and slightly elevated flank. There is a two-fold advantage of this position: transurethral and transrenal access can be obtained using a combined approach. In the present study, this simple technique is used to position a floppy guide wire through a modified needle directly through the renal pelvis into the ureter. MATERIALS AND METHODS: The kidney is punctured in the modified lithotomy position under sonographic control using an initial three-part puncture needle. A floppy tip guide-wire is inserted into the collecting system via the needle after retrieving the stylet. The retracted needle is bent at the tip while the guide-wire is secured in the needle and the collecting system. The use of the floppy tip guide-wire helps to insert the curved needle back into the kidney pelvis, which becomes the precise guidance for the now steerable wire. The desired steerable stent is positioned under radiographic control in a retrograde fashion over the endoscopically harbored tip of the guide-wire. Two patient cohorts (newly described method and conventional method were compared. RESULTS: The presented steering procedure saves 16.5 mean minutes compared to the conventional antegrade stenting and 79.5 Euros compared to the control group. CONCLUSION: The described combined antegrade-retrograde stent placement through a bent three-part puncture needle results in both clinical superiority (OR time, success rate and financial benefits.

  7. Variation in lumbar punctures for early onset neonatal sepsis: a nationally representative serial cross-sectional analysis, 2003-2009

    Directory of Open Access Journals (Sweden)

    Patrick Stephen W

    2012-08-01

    Full Text Available Abstract Background Whether lumbar punctures (LPs should be performed routinely for term newborns suspected of having early onset neonatal sepsis (EONS is subject to debate. It is unclear whether variations in performance of LPs for EONS may be associated with patient, hospital, insurance or regional factors. Our objective was to identify characteristics associated with the practice of performing LPs for suspected EONS in a nationally representative sample. Methods Utilizing data from the 2003, 2006 and 2009 Kids’ Inpatient Database (KID compiled by the Agency for Healthcare Research and Quality, we examined the frequency and characteristics of term, normal-birth weight newborns receiving an LP for EONS. Survey-weighting was applied for national estimates and used in chi squared and multivariable regression analysis. Results In 2009, there were 13,694 discharges for term newborns that underwent LPs for apparent EONS. Newborns having LPs performed were more likely to be covered by Medicaid vs. private insurance (51.9 vs. 45.1 percent; p Conclusions We found pronounced variation in LPs performed for EONS, even when adjusting for clinical conditions that would prompt LPs. These findings indicate practice variations in newborn care that merit further examination and explanation.

  8. Tissue Sampling Guides for Porcine Biomedical Models.

    Science.gov (United States)

    Albl, Barbara; Haesner, Serena; Braun-Reichhart, Christina; Streckel, Elisabeth; Renner, Simone; Seeliger, Frank; Wolf, Eckhard; Wanke, Rüdiger; Blutke, Andreas

    2016-04-01

    This article provides guidelines for organ and tissue sampling adapted to porcine animal models in translational medical research. Detailed protocols for the determination of sampling locations and numbers as well as recommendations on the orientation, size, and trimming direction of samples from ∼50 different porcine organs and tissues are provided in the Supplementary Material. The proposed sampling protocols include the generation of samples suitable for subsequent qualitative and quantitative analyses, including cryohistology, paraffin, and plastic histology; immunohistochemistry;in situhybridization; electron microscopy; and quantitative stereology as well as molecular analyses of DNA, RNA, proteins, metabolites, and electrolytes. With regard to the planned extent of sampling efforts, time, and personnel expenses, and dependent upon the scheduled analyses, different protocols are provided. These protocols are adjusted for (I) routine screenings, as used in general toxicity studies or in analyses of gene expression patterns or histopathological organ alterations, (II) advanced analyses of single organs/tissues, and (III) large-scale sampling procedures to be applied in biobank projects. Providing a robust reference for studies of porcine models, the described protocols will ensure the efficiency of sampling, the systematic recovery of high-quality samples representing the entire organ or tissue as well as the intra-/interstudy comparability and reproducibility of results. © The Author(s) 2016.

  9. CT-Guided Percutaneous Radiologic Gastrostomy for Patients with Head and Neck Cancer: A Retrospective Evaluation in 177 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Akio, E-mail: a.akahane@gmail.com; Kato, Kenichi, E-mail: kkato@iwate-med.ac.jp; Suzuki, Michiko, E-mail: mamimichiko@me.com [Iwate Medical University School of Medicine, Department of Radiology (Japan); Sone, Miyuki, E-mail: msone@me.com [National Cancer Center Hospital, Department of Diagnostic Radiology (Japan); Tanaka, Ryoichi, E-mail: rtanaka@iwate-med.ac.jp; Nakasato, Tatsuhiko, E-mail: nakasato@iwate-med.ac.jp; Ehara, Shigeru, E-mail: ehara@iwate-med.ac.jp [Iwate Medical University School of Medicine, Department of Radiology (Japan)

    2016-02-15

    PurposeThe purpose of this study was to assess the technical success rate and adverse events (AEs) associated with computed tomography (CT)-guided percutaneous gastrostomy for patients with head and neck cancer (HNC).Materials and MethodsThis retrospective study included patients with HNC who had undergone CT-guided percutaneous gastrostomy between February 2007 and December 2013. Information regarding the patients’ backgrounds, CT-guided percutaneous gastrostomy techniques, technical success rate, and AEs were obtained from the medical records. In all patients, the stomach was punctured under CT fluoroscopy with a Funada gastropexy device.ResultsDuring the study period, 177 patients underwent CT-guided percutaneous gastrostomy. The most common tumor location was the oral cavity, followed by the pharynx and maxilla. The indication for CT-guided percutaneous gastrostomy were tumor obstruction in 78 patients, postoperative dysphagia in 55 patients, radiation edema in 43 patients, and cerebral infarction in 1 patient. The technical success rate was 97.7 %. The overall mean procedure time was 25.3 min. Major AEs occurred in seven patients (4.0 %), including bleeding (n = 4), colonic injury (n = 1), gastric tear (n = 1), and aspiration pneumonia (n = 1). Minor AEs occurred in 15 patients (8.5 %), which included peristomal leakage (n = 6), irritation (n = 4), inadvertent removal (n = 2), peristomal hemorrhage (n = 1), peristomal infection (n = 1), and wound granulation (n = 1). The mean follow-up period was 111 days (range 1–1106 days).ConclusionOur study suggests that CT-guided gastrostomy may be suitable in patients with HNC.

  10. CT-Guided Percutaneous Radiologic Gastrostomy for Patients with Head and Neck Cancer: A Retrospective Evaluation in 177 Patients

    International Nuclear Information System (INIS)

    Tamura, Akio; Kato, Kenichi; Suzuki, Michiko; Sone, Miyuki; Tanaka, Ryoichi; Nakasato, Tatsuhiko; Ehara, Shigeru

    2016-01-01

    PurposeThe purpose of this study was to assess the technical success rate and adverse events (AEs) associated with computed tomography (CT)-guided percutaneous gastrostomy for patients with head and neck cancer (HNC).Materials and MethodsThis retrospective study included patients with HNC who had undergone CT-guided percutaneous gastrostomy between February 2007 and December 2013. Information regarding the patients’ backgrounds, CT-guided percutaneous gastrostomy techniques, technical success rate, and AEs were obtained from the medical records. In all patients, the stomach was punctured under CT fluoroscopy with a Funada gastropexy device.ResultsDuring the study period, 177 patients underwent CT-guided percutaneous gastrostomy. The most common tumor location was the oral cavity, followed by the pharynx and maxilla. The indication for CT-guided percutaneous gastrostomy were tumor obstruction in 78 patients, postoperative dysphagia in 55 patients, radiation edema in 43 patients, and cerebral infarction in 1 patient. The technical success rate was 97.7 %. The overall mean procedure time was 25.3 min. Major AEs occurred in seven patients (4.0 %), including bleeding (n = 4), colonic injury (n = 1), gastric tear (n = 1), and aspiration pneumonia (n = 1). Minor AEs occurred in 15 patients (8.5 %), which included peristomal leakage (n = 6), irritation (n = 4), inadvertent removal (n = 2), peristomal hemorrhage (n = 1), peristomal infection (n = 1), and wound granulation (n = 1). The mean follow-up period was 111 days (range 1–1106 days).ConclusionOur study suggests that CT-guided gastrostomy may be suitable in patients with HNC

  11. Direct Puncture Embolization of Scalp Arteriovenous Malformation in a Patient with Severe Hemophilia A: A Case Report

    International Nuclear Information System (INIS)

    Lee, Kyung Mi; Kim, Eui Jong; Park, Bong Jin; Kim, Keon Ha

    2011-01-01

    We present a case of scalp arteriovenous malformation (AVM) in a patient with severe hemophilia A. The 22-year-old man presented with a pulsatile right parietal scalp mass. Digital subtraction angiography revealed an AVM in the right parietal scalp, supplied by superficial temporal and occipital arteries that drained into multiple venous structures. We successfully performed direct puncture embolization followed by surgical resection of the scalp AVM in conjunction with supplemental infusion of coagulation factor VIII before, during and after the embolization and the operation.

  12. Direct Puncture Embolization of Scalp Arteriovenous Malformation in a Patient with Severe Hemophilia A: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Mi; Kim, Eui Jong [Dept. of Radiology, Kyung Hee University Hospital, Kyung Hee University Graduate School of Medicine, Seoul (Korea, Republic of); Park, Bong Jin [Dept. of Neurosurgery, Kyung Hee University Hospital, Kyung Hee University Graduate School of Medicine, Seoul (Korea, Republic of); Kim, Keon Ha [Dept. of Radiology, Samsug Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2011-09-15

    We present a case of scalp arteriovenous malformation (AVM) in a patient with severe hemophilia A. The 22-year-old man presented with a pulsatile right parietal scalp mass. Digital subtraction angiography revealed an AVM in the right parietal scalp, supplied by superficial temporal and occipital arteries that drained into multiple venous structures. We successfully performed direct puncture embolization followed by surgical resection of the scalp AVM in conjunction with supplemental infusion of coagulation factor VIII before, during and after the embolization and the operation.

  13. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    Science.gov (United States)

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    difference of 12% [95% CI, 2-22]; P = 0.0091), as was surgical success rate (82% [95% CI, 74%-89%] vs 93% [95% CI, 86%-97%]; proportion difference of 11% [95% CI 1-20]; P = 0.0153). Sensory block onset also was slower in group A (log rank test P = 0.0020). Performance times were faster in group I (231 seconds [95% CI, 213-250]) than in group A (358 seconds [95% CI, 332-387]; P < 0.0001). No statistically significant difference was observed for vascular puncture, paresthesia during block performance, or procedure-related pain. No neurologic complication was noted at follow-up. We failed to demonstrate that the rate of complete sensory block of the double-injection axillary block is noninferior to the single-injection infraclavicular block. However, the rate of complete sensory block at 30 minutes is statistically significantly lower with the axillary block. The ultrasound-guided single-injection infraclavicular block thus seems to be the preferred technique over the axillary for upper arm anesthesia.

  14. Translocation dynamics of Pu(NO3)4 and PuO2 from puncture wounds to lymph nodes and major organs of beagles

    International Nuclear Information System (INIS)

    Bistline, R.W.; Lebel, J.L.; Dagle, G.E.

    1976-01-01

    The translocation dynamics of plutonium and americium from simulated puncture wounds in the paws of beagle dogs following contamination with Pu(NO 3 ) 4 and high-fired PuO 2 was studied. Fractions of initial implant transported to the first major lymph node and to major body organs were measured with in vivo counting equipment and by radiochemical analysis of tissue material collected at necropsy. Samples were obtained from serial necropsies ranging from 2 weeks to 1 year after implant. The difference in lymph node and organ-accumulation dynamics between the two chemical forms and the effects of diethylenetriaminepentaacetate (DTPA) chelation treatment are presented. Active mechanisms to transport plutonium to and from the lymph system appear to exist. Equations for buildup in the lymph nodes and organs are included. The data suggest a buildup in the lymph node to a maximum, followed by a long negative slope, and a possible dose-rate effect from Pu(NO 3 ) 4 in lymph nodes

  15. Percutaneous Ultrasonography as Imaging Modality and Sampling Guide for Pulmonologists

    NARCIS (Netherlands)

    Stigt, Jos A.; Groen, Harry J. M.

    2014-01-01

    Ultrasound (US) imaging is gradually progressing into common practice in contemporary pulmonology. Its main applications are to determine the presence and amount of pleural effusions and to guide subsequent treatment interventions. Guidelines recommend the use of US for these indications. Training

  16. Accuracy of biopsy needle navigation using the Medarpa system - computed tomography reality superimposed on the site of intervention

    International Nuclear Information System (INIS)

    Khan, M. Fawad; Maataoui, Adel; Gurung, Jessen; Schiemann, Mirko; Vogl, Thomas J.; Dogan, Selami; Ackermann, Hanns; Wesarg, Stefan; Sakas, Georgios

    2005-01-01

    The aim of this work was to determine the accuracy of a new navigational system, Medarpa, with a transparent display superimposing computed tomography (CT) reality on the site of intervention. Medarpa uses an optical and an electromagnetic tracking system which allows tracking of instruments, the radiologist and the transparent display. The display superimposes a CT view of a phantom chest on a phantom chest model, in real time. In group A, needle positioning was performed using the Medarpa system. Three targets (diameter 1.5 mm) located inside the phantom were punctured. In group B, the same targets were used to perform standard CT-guided puncturing using the single-slice technique. The same needles were used in both groups (15 G, 15 cm). A total of 42 punctures were performed in each group. Post puncture, CT scans were made to verify needle tip positions. The mean deviation from the needle tip to the targets was 6.65±1.61 mm for group A (range 3.54-9.51 mm) and 7.05±1.33 mm for group B (range 4.10-9.45 mm). No significant difference was found between group A and group B for any target (p>0.05). No significant difference was found between the targets of the same group (p>0.05). The accuracy in needle puncturing using the augmented reality system, Medarpa, matches the accuracy achieved by CT-guided puncturing technique. (orig.)

  17. Shade guide optimization--a novel shade arrangement principle for both ceramic and composite shade guides when identifying composite test objects.

    Science.gov (United States)

    Østervemb, Niels; Jørgensen, Jette Nedergaard; Hørsted-Bindslev, Preben

    2011-02-01

    The most widely used shade guide for composite materials is made of ceramic and arranged according to a non-proven method. There is a need for a composite shade guide using a scientifically based arrangement principle. To compare the shade tab arrangement of the Vitapan Classical shade guide and an individually made composite shade guide using both the originally proposed arrangement principle and arranged according to ΔE2000 values with hue group division. An individual composite shade guide made from Filtek Supreme XT body colors was compared to the Vitapan Classical shade guide. Twenty-five students matched color samples made from Filtek Supreme XT body colors using the two shade guides arranged after the two proposed principles--four shade guides in total. Age, sequence, gender, time, and number of correct matches were recorded. The proposed visually optimal composite shade guide was both fastest and had the highest number of correct matches. Gender was significantly associated with time used for color sampling but not regarding the number of correct shade matches. A composite shade guide is superior compared to the ceramic Vitapan Classical guide when using composite test objects. A rearrangement of the shade guide according to hue, subdivided according to ΔE2000, significantly reduces the time needed to take a color sample and increases the number of correct shade matches. Total color difference in relation to the lightest tab with hue group division is recommended as a possible and universally applicable mode of tab arrangement in dental color standards. Moreover, a shade guide made of the composite materials itself is to be preferred as both a faster and more accurate method of determining color. © 2011, COPYRIGHT THE AUTHORS. JOURNAL COMPILATION © 2011, WILEY PERIODICALS, INC.

  18. Pancreatic duct drainage using EUS-guided rendezvous technique for stenotic pancreaticojejunostomy.

    Science.gov (United States)

    Takikawa, Tetsuya; Kanno, Atsushi; Masamune, Atsushi; Hamada, Shin; Nakano, Eriko; Miura, Shin; Ariga, Hiroyuki; Unno, Jun; Kume, Kiyoshi; Kikuta, Kazuhiro; Hirota, Morihisa; Yoshida, Hiroshi; Katayose, Yu; Unno, Michiaki; Shimosegawa, Tooru

    2013-08-21

    The patient was a 30-year-old female who had undergone excision of the extrahepatic bile duct and Roux-en-Y hepaticojejunostomy for congenital biliary dilatation at the age of 7. Thereafter, she suffered from recurrent acute pancreatitis due to pancreaticobiliary maljunction and received subtotal stomach-preserving pancreaticoduodenectomy. She developed a pancreatic fistula and an intra-abdominal abscess after the operation. These complications were improved by percutaneous abscess drainage and antibiotic therapy. However, upper abdominal discomfort and the elevation of serum pancreatic enzymes persisted due to stenosis from the pancreaticojejunostomy. Because we could not accomplish dilation of the stenosis by endoscopic retrograde cholangiopancreatography, we tried an endoscopic ultrasonography (EUS) guided rendezvous technique for pancreatic duct drainage. After transgastric puncture of the pancreatic duct using an EUS-fine needle aspiration needle, the guidewire was inserted into the pancreatic duct and finally reached to the jejunum through the stenotic anastomosis. We changed the echoendoscope to an oblique-viewing endoscope, then grasped the guidewire and withdrew it through the scope. The stenosis of the pancreaticojejunostomy was dilated up to 4 mm, and a pancreatic stent was put in place. Though the pancreatic stent was removed after three months, the patient remained symptom-free. Pancreatic duct drainage using an EUS-guided rendezvous technique was useful for the treatment of a stenotic pancreaticojejunostomy after pancreaticoduodenectomy.

  19. Triangulating case-finding tools for patient safety surveillance: a cross-sectional case study of puncture/laceration.

    Science.gov (United States)

    Taylor, Jennifer A; Gerwin, Daniel; Morlock, Laura; Miller, Marlene R

    2011-12-01

    To evaluate the need for triangulating case-finding tools in patient safety surveillance. This study applied four case-finding tools to error-associated patient safety events to identify and characterise the spectrum of events captured by these tools, using puncture or laceration as an example for in-depth analysis. Retrospective hospital discharge data were collected for calendar year 2005 (n=48,418) from a large, urban medical centre in the USA. The study design was cross-sectional and used data linkage to identify the cases captured by each of four case-finding tools. Three case-finding tools (International Classification of Diseases external (E) and nature (N) of injury codes, Patient Safety Indicators (PSI)) were applied to the administrative discharge data to identify potential patient safety events. The fourth tool was Patient Safety Net, a web-based voluntary patient safety event reporting system. The degree of mutual exclusion among detection methods was substantial. For example, when linking puncture or laceration on unique identifiers, out of 447 potential events, 118 were identical between PSI and E-codes, 152 were identical between N-codes and E-codes and 188 were identical between PSI and N-codes. Only 100 events that were identified by PSI, E-codes and N-codes were identical. Triangulation of multiple tools through data linkage captures potential patient safety events most comprehensively. Existing detection tools target patient safety domains differently, and consequently capture different occurrences, necessitating the integration of data from a combination of tools to fully estimate the total burden.

  20. Splenic tuberculosis. Report of twelve cases

    International Nuclear Information System (INIS)

    Adil, A.; Chikhaoui, N.; Ousehal, A.; Kadiri, R.

    1995-01-01

    Tuberculosis of the spleen is not exceptional. The authors report ten cases which occurred with a predominance in young male adults. All patients had at least one other site of tuberculosis without any HIV infection. All patients had focal splenic lesions in the form of scattered hypo-echogenic and hypodense nodules. These nodules had a pseudo-tumor appearance in one case. CT-guided puncture was performed in one case. Splenic tuberculosis is not as rare as is sometimes thought. The CT-guided splenic puncture is now performed routinely and remains the ideal diagnostic approach. (authors). 9 refs., 5 figs

  1. Recent Ultrasonic Guided Wave Inspection Development Efforts

    International Nuclear Information System (INIS)

    Rose, Joseph L.; Tittmann, Bernhard R.

    2001-01-01

    The recognition of such natural wave guides as plates, rods, hollow cylinders, multi-layer structures or simply an interface between two materials combined with an increased understanding of the physics and wave mechanics of guided wave propagation has led to a significant increase in the number of guided wave inspection applications being developed each year. Of primary attention Is the ability to inspect partially hidden structures, hard to access areas, and treated or insulated structures. An introduction to some physical consideration of guided waves followed by some sample problem descriptions in pipe, ice detection, fouling detection in the foods industry, aircraft, tar coated structures and acoustic microscopy is presented in this paper. A sample problem in Boundary Element Modeling is also presented to illustrate the move in guided wave analysis beyond detection and location analysis to quantification

  2. Complete removal of a breast mass by US-guided mammotome biopsy: histologic assessment by marginal sampling

    International Nuclear Information System (INIS)

    Kim, Youn Jeong; Choi, Hye Young; Moon, Byung In; Lee, Shi Nae

    2005-01-01

    The aim of this study was to assess whether the complete removal of a breast mass using ultrasound (US) guided mammotome biopsy was successful using a marginal biopsy after insuring the total visual excision of the breast mass on US images. The relationship of complete breast mass removal, and the hematoma, mass size and shape were also evaluated. A US guided mammotome biopsy was performed in a total of 136 cases in 133 patients, with marginal biopsies also added when the complete removal of breast mass had been identified by sonography. The results of the marginal biopsies were serially dividing into three groups, as follows: group I were the cases in the initial 6 months, group II after the initial 6 months and group III having undergone two marginal biopsies. The marginal biopsies were performed in four directions around the probe, with 'marginal positivity' defined as the same histopathological findings to that of the main mass in at least one direction. A statistical analysis was also used to evaluate between the marginal positivity and the hematoma, mass size and shape. The marginal positivities of groups I, II and III were 48.8, 29.4 and 45.5%, respectively. The marginal positivity of those with a lobular shaped mass was significantly higher (ρ = 0.0121) than those with round or oval shaped masses (61.5 vs 33.7 vs 50%), but showed no statistical relationship with hematoma size of the lesions. Although the lesions were removed by US using a US-guided mammotome biopsy, many residual lesions were still histologically present in the marginal samplings, especially in the lobular shaped masse

  3. How to achieve ultrasound-guided femoral venous access: the new standard of care in the electrophysiology laboratory.

    Science.gov (United States)

    Wiles, Benedict M; Child, Nicholas; Roberts, Paul R

    2017-06-01

    Bedside vascular ultrasound machines are increasingly available. They are used to facilitate safer vascular access across a number of different specialties. In the electrophysiology laboratory however, where patients are frequently anticoagulated and require the insertion of multiple venous sheaths, anatomical landmark techniques predominate. Despite the high number of vascular complications associated with electrophysiological procedures and the increasing evidence to support its use in electrophysiology, ultrasound remains underutilised. A new standard of care is required. A comprehensive technical report, providing a detailed explanation of this important technique, will provide other electrophysiology centres with the knowledge and justification for adopting ultrasound guidance as their standard practice. We review the increasing body of evidence which demonstrates that routine ultrasound usage can substantially improve the safety of femoral venous access in the electrophysiology laboratory. We offer a comprehensive technical report to guide operators through the process of ultrasound-guided venous access, with a specific focus on the electrophysiology laboratory. Additionally, we detail a novel technique which utilises real-time colour Doppler ultrasound to accurately identify needle tip location during venous puncture. The use of vascular ultrasound to guide femoral venous cannulation is rapid, inexpensive and easily learnt. Ultrasound is readily available and offers the potential to significantly reduce vascular complications in the unique setting of the electrophysiology laboratory. Ultrasound guidance to achieve femoral venous access should be the new standard of care in electrophysiology.

  4. Ultrasound Guided Percutaneous Nephrostomy: Experience at ...

    African Journals Online (AJOL)

    2018-01-30

    Jan 30, 2018 ... success and ease of puncture. The most common ... a longer learning curve. Adequate training, careful patients selection, and patience are key to success. ... practice.[1] It has the advantages of being fast, can be done in the ...

  5. Knowledge and attitudes of Iranian patients with regard to lumbar puncture

    International Nuclear Information System (INIS)

    Borhani-Haghighi, Afshin; Shariat, Abolhamid; Rezaei, Razieh; Etemadi, Samaneh; Ghaem, Haleh

    2009-01-01

    To investigate the knowledge and attitudes of patients towards lumbar puncture (LP), its complications, and indications. In a questionnaire survey, patients who were referred to the general neurology outpatient clinic at Nemazee Hospital in Shiraz, Iran, from January 2007 to January 2008 were invited to complete a questionnaire consisting of items on demographic and socioeconomic variables, experiences with LP and complications, and knowledge of and attitudes regarding LP. A total of 410 patients were recruited (58% women, mean age 33.2 + - 2.7 years). Poor knowledge of LP was highly prevalent (92.6%), and negative attitudes toward LP were also common (63%) among our patients. Skepticism regarding LP was directly related to lack of information (p=0.00007). Lower socioeconomic status, lower educational level, and residence in rural areas were associated with being less well informed about LP, but interestingly those who had experience with LP before were better informed and had more positive attitudes. It is possible to overcome reluctance to undergo LP through education of its indications, contraindications, and complications. (author)

  6. Improved efficiency of nanoneedle insertion by modification with a cell-puncturing protein

    Science.gov (United States)

    Ryu, Seunghwan; Matsumoto, Yuta; Matsumoto, Takahiro; Ueno, Takafumi; Silberberg, Yaron R.; Nakamura, Chikashi

    2018-03-01

    An atomic force microscope (AFM) probe etched into an ultra-sharp cylindrical shape (a nanoneedle) can be inserted into a living cell and mechanical responses of the insertion process are represented as force-distance curves using AFM. A probe-molecule-functionalized nanoneedle can be used to detect intracellular molecules of interest in situ. The insertion efficiencies of nanoneedles vary among cell types due to the cortex structures of cells, and some cell types, such as mouse fibroblast Balb/3T3 cells, show extremely low efficacy of insertion. We addressed this issue by using a cell membrane puncturing protein from bacteriophage T4 (gp5), a needle-like protein that spontaneously penetrates through the cell membrane. Gp5 was immobilized onto a nanoneedle surface. The insertion efficiency of the functionalized nanoneedle increased by over 15% compared to the non-functionalized control. Gp5-modification is a versatile approach in cell manipulation techniques for the insertion of other types of nanostructures into cells.

  7. Endovascular treatment of iliofemoral deep vein thrombosis in pregnancy using US-guided percutaneous aspiration thrombectomy.

    Science.gov (United States)

    Gedikoglu, Murat; Oguzkurt, Levent

    2017-01-01

    We aimed to describe ultrasonography (US)-guided percutaneous aspiration thrombectomy in pregnant women with iliofemoral deep vein thrombosis. This study included nine pregnant women with acute and subacute iliofemoral deep vein thrombosis, who were severe symptomatic cases with massive swelling and pain of the leg. Patients were excluded from the study if they had only femoropopliteal deep vein thrombosis or mild symptoms of deep vein thrombosis. US-guided percutaneous aspiration thrombectomy was applied to achieve thrombus removal and uninterrupted venous flow. The treatment was considered successful if there was adequate venous patency and symptomatic relief. Complete or significant thrombus removal and uninterrupted venous flow from the puncture site up to the iliac veins were achieved in all patients at first intervention. Complete relief of leg pain was achieved immediately in seven patients (77.8%). Two patients (22.2%) had a recurrence of thrombosis in the first week postintervention. One of them underwent a second intervention, where percutaneous aspiration thrombectomy was performed again with successful removal of thrombus and establishment of in line flow. Two patients were lost to follow-up after birth. None of the remaining seven patients had rethrombosis throughout the postpartum period. Symptomatic relief was detected clinically in these patients. Endovascular treatment with US-guided percutaneous aspiration thrombectomy can be considered as a safe and effective way to remove thrombus from the deep veins in pregnant women with acute and subacute iliofemoral deep vein thrombosis.

  8. Learning curve of thyroid fine-needle aspiration biopsy.

    Science.gov (United States)

    Penín, Manuel; Martín, M Ángeles; San Millán, Beatriz; García, Juana

    2017-12-01

    Fine-needle aspiration biopsy (FNAB) is the reference procedure for thyroid nodule evaluation. Its main limitation are inadequate samples, which should be less than 20%. To analyze the learning curve of the procedure by comparing the results of a non-experienced endocrinologist (endocrinologist 2) to those of an experienced one (endocrinologist 1). Sixty FNABs were analyzed from February to June 2016. Each endocrinologist made 2punctures of every nodule in a random order. This order and the professional making every puncture were unknown to the pathologist who examined the samples. Endocrinologist 1 had a higher percentage of diagnoses than endocrinologist 2 (82% vs. 72%, P=.015). In the first 20 FNABs, the difference between both physicians was remarkable and statistically significant (80% vs. 50%, P=.047). In the following 20 FNABs, the difference narrowed and was not statistically significant (90% vs. 65%, P=.058). In the final 20 FNABs, the difference was minimal and not statistically significant (75% vs. 70%, P=.723). The learning curve of ultrasound-guided FNAB may be completed in a suitable environment by performing it at least 60 times. Although the guidelines recommend at least 3punctures per nodule, 2are enough to achieve an accurate percentage of diagnoses. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Ultrasound guided implantation of chest port systems via the lateral subclavian vein; Die sonographisch gezielte Implantation von Portkathetersystemen ueber die laterale Vena subclavia

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K. [Inst. fuer Radiologische Diagnostik, Univ. zu Koeln (Germany); Warm, M. [Gynaekologie, Univ. zu Koeln (Germany); Reiser, M. [Medizinische Klinik I, Univ. zu Koeln (Germany); Toex, U. [Medizinische Klinik IV, Univ. zu Koeln (Germany)

    2006-03-15

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  10. Quantitative analysis of disc degeneration using axial T2 mapping in a percutaneous annular puncture model in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Jee Won; Kim, Su Jin [Dept. of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); Kang, Heung Sik; Lee, Joon Woo [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Hong, Sung Hwan [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2016-02-15

    To evaluate T2 relaxation time change using axial T2 mapping in a rabbit degenerated disc model and determine the most correlated variable with histologic score among T2 relaxation time, disc height index, and Pfirrmann grade. Degenerated disc model was made in 4 lumbar discs of 11 rabbits (n = 44) by percutaneous annular puncture with various severities of an injury. Lumbar spine lateral radiograph, MR T2 sagittal scan and MR axial T2 mapping were obtained at baseline and 2 weeks and 4 weeks after the injury in 7 rabbits and at baseline and 2 weeks, 4 weeks, and 6 weeks after the injury in 4 rabbits. Generalized estimating equations were used for a longitudinal analysis of changes in T2 relaxation time in degenerated disc model. T2 relaxation time, disc height index and Pfirrmann grade were correlated with the histologic scoring of disc degeneration using Spearman's rho test. There was a significant difference in T2 relaxation time between uninjured and injured discs after annular puncture. Progressive decrease in T2 relaxation time was observed in injured discs throughout the study period. Lower T2 relaxation time was observed in the more severely injured discs. T2 relaxation time showed the strongest inverse correlation with the histologic score among the variables investigated (r = -0.811, p < 0.001). T2 relaxation time measured with axial T2 mapping in degenerated discs is a potential method to assess disc degeneration.

  11. Sampling strategies for subsampled segmented EPI PRF thermometry in MR guided high intensity focused ultrasound

    Science.gov (United States)

    Odéen, Henrik; Todd, Nick; Diakite, Mahamadou; Minalga, Emilee; Payne, Allison; Parker, Dennis L.

    2014-01-01

    Purpose: To investigate k-space subsampling strategies to achieve fast, large field-of-view (FOV) temperature monitoring using segmented echo planar imaging (EPI) proton resonance frequency shift thermometry for MR guided high intensity focused ultrasound (MRgHIFU) applications. Methods: Five different k-space sampling approaches were investigated, varying sample spacing (equally vs nonequally spaced within the echo train), sampling density (variable sampling density in zero, one, and two dimensions), and utilizing sequential or centric sampling. Three of the schemes utilized sequential sampling with the sampling density varied in zero, one, and two dimensions, to investigate sampling the k-space center more frequently. Two of the schemes utilized centric sampling to acquire the k-space center with a longer echo time for improved phase measurements, and vary the sampling density in zero and two dimensions, respectively. Phantom experiments and a theoretical point spread function analysis were performed to investigate their performance. Variable density sampling in zero and two dimensions was also implemented in a non-EPI GRE pulse sequence for comparison. All subsampled data were reconstructed with a previously described temporally constrained reconstruction (TCR) algorithm. Results: The accuracy of each sampling strategy in measuring the temperature rise in the HIFU focal spot was measured in terms of the root-mean-square-error (RMSE) compared to fully sampled “truth.” For the schemes utilizing sequential sampling, the accuracy was found to improve with the dimensionality of the variable density sampling, giving values of 0.65 °C, 0.49 °C, and 0.35 °C for density variation in zero, one, and two dimensions, respectively. The schemes utilizing centric sampling were found to underestimate the temperature rise, with RMSE values of 1.05 °C and 1.31 °C, for variable density sampling in zero and two dimensions, respectively. Similar subsampling schemes

  12. CT-Guided Transgluteal Biopsy for Systematic Random Sampling of the Prostate in Patients Without Rectal Access.

    Science.gov (United States)

    Goenka, Ajit H; Remer, Erick M; Veniero, Joseph C; Thupili, Chakradhar R; Klein, Eric A

    2015-09-01

    The objective of our study was to review our experience with CT-guided transgluteal prostate biopsy in patients without rectal access. Twenty-one CT-guided transgluteal prostate biopsy procedures were performed in 16 men (mean age, 68 years; age range, 60-78 years) who were under conscious sedation. The mean prostate-specific antigen (PSA) value was 11.4 ng/mL (range, 2.3-39.4 ng/mL). Six had seven prior unsuccessful transperineal or transurethral biopsies. Biopsy results, complications, sedation time, and radiation dose were recorded. The mean PSA values and number of core specimens were compared between patients with malignant results and patients with nonmalignant results using the Student t test. The average procedural sedation time was 50.6 minutes (range, 15-90 minutes) (n = 20), and the mean effective radiation dose was 8.2 mSv (median, 6.6 mSv; range 3.6-19.3 mSv) (n = 13). Twenty of the 21 (95%) procedures were technically successful. The only complication was a single episode of gross hematuria and penile pain in one patient, which resolved spontaneously. Of 20 successful biopsies, 8 (40%) yielded adenocarcinoma (Gleason score: mean, 8; range, 7-9). Twelve biopsies yielded nonmalignant results (60%): high-grade prostatic intraepithelial neoplasia (n = 3) or benign prostatic tissue with or without inflammation (n = 9). Three patients had carcinoma diagnosed on subsequent biopsies (second biopsy, n = 2 patients; third biopsy, n = 1 patient). A malignant biopsy result was not significantly associated with the number of core specimens (p = 0.3) or the mean PSA value (p = 0.1). CT-guided transgluteal prostate biopsy is a safe and reliable technique for the systematic random sampling of the prostate in patients without a rectal access. In patients with initial negative biopsy results, repeat biopsy should be considered if there is a persistent rise in the PSA value.

  13. Comparison of EUS-guided rendezvous and precut papillotomy techniques for biliary access (with videos).

    Science.gov (United States)

    Dhir, Vinay; Bhandari, Suryaprakash; Bapat, Mukta; Maydeo, Amit

    2012-02-01

    Precut papillotomy after failed bile duct cannulation is associated with an increased risk of pancreatitis. EUS-guided rendezvous drainage is a novel alternative technique, but there are no data comparing this approach with precut papillotomy. To evaluate the safety and efficacy of EUS-guided rendezvous drainage of the bile duct and compare its outcome with that of precut papillotomy. Retrospective study. Tertiary care referral center. Consecutive patients with distal bile duct obstruction, in whom selective cannulation of the bile duct at ERCP failed after 5 attempts with a guidewire and sphincterotome, underwent an EUS-guided rendezvous procedure. The outcomes were compared with those in a historical cohort of patients who underwent precut papillotomy. Patients in whom selective cannulation failed underwent EUS-guided rendezvous drainage by use of the short wire technique or precut papillotomy by use of the Erlangen papillotome. At EUS, after the extrahepatic bile duct was punctured with a 19-gauge needle, a hydrophilic angled-tip guidewire 260 cm long was passed in an antegrade manner across the papilla into the duodenum. The echoendoscope was then exchanged for a duodenoscope, which was introduced alongside the EUS-placed guidewire. The transpapillary guidewire was retrieved through its biopsy channel, and accessories were passed over the wire to perform the requisite endotherapy. Comparison of the rates of technical success and complications between patients treated by the EUS-guided rendezvous and those treated by precut papillotomy techniques. Treatment success was defined as completion of the requisite endotherapy in one treatment session. Treatment success was significantly higher for the EUS-guided rendezvous (57/58 patients) than for those undergoing precut papillotomy technique (130/144 patients) (98.3% vs 90.3%; P = .03). There was no significant difference in the rate of procedural complications between the EUS and precut papillotomy techniques (3

  14. Ultrasound-guided stellate ganglion blocks combined with pharmacological and occupational therapy in Complex Regional Pain Syndrome (CRPS): a pilot case series ad interim.

    Science.gov (United States)

    Wei, Karin; Feldmann, Robert E; Brascher, Anne-Kathrin; Benrath, Justus

    2014-12-01

    This preliminary and retrospective pilot case series examines a treatment concept consisting of ultrasound-guided stellate ganglion blocks (SGBs) combined with pharmacological and occupational therapy in patients with complex regional pain syndrome (CRPS) of the hand. Efficacy of combined treatment concepts and safety of ultrasound-guided SGB have not been sufficiently investigated yet. A total number of 156 blocks were evaluated in 16 patients with CRPS in a retrospective analysis. All patients received pharmacotherapy and a standard regimen of occupational therapy offered simultaneously to the SGBs. Changes in both spontaneous and evoked pain levels were assessed by numerical pain rating score before and after the last blockade of a series. Side effects were documented. The overall mean pain reduction was 63.2% regarding spontaneous and 45.3% regarding evoked pain. Mild complications, such as hoarseness or dysphagia, occurred in 13.5% of the blocks (21 SGBs). Serious complications, such as plexus paresis or accidental puncture of vessels or other structures, did not occur. Time between symptom onset and start of treatment did not affect the extent of pain reduction. The combination of ultrasound-guided SGB and simultaneous pharmacological and occupational therapy showed encouraging treatment results under conditions of this pilot case series. Assessment of efficacy of this combined treatment concept and safety of ultrasound-guided SGB require further prospective clinical studies with larger number of participants. Wiley Periodicals, Inc.

  15. Using NDVI and guided sampling to develop yield prediction maps of processing tomato crop

    Energy Technology Data Exchange (ETDEWEB)

    Fortes, A.; Henar Prieto, M. del; García-Martín, A.; Córdoba, A.; Martínez, L.; Campillo, C.

    2015-07-01

    The use of yield prediction maps is an important tool for the delineation of within-field management zones. Vegetation indices based on crop reflectance are of potential use in the attainment of this objective. There are different types of vegetation indices based on crop reflectance, the most commonly used of which is the NDVI (normalized difference vegetation index). NDVI values are reported to have good correlation with several vegetation parameters including the ability to predict yield. The field research was conducted in two commercial farms of processing tomato crop, Cantillana and Enviciados. An NDVI prediction map developed through ordinary kriging technique was used for guided sampling of processing tomato yield. Yield was studied and related with NDVI, and finally a prediction map of crop yield for the entire plot was generated using two geostatistical methodologies (ordinary and regression kriging). Finally, a comparison was made between the yield obtained at validation points and the yield values according to the prediction maps. The most precise yield maps were obtained with the regression kriging methodology with RRMSE values of 14% and 17% in Cantillana and Enviciados, respectively, using the NDVI as predictor. The coefficient of correlation between NDVI and yield was correlated in the point samples taken in the two locations, with values of 0.71 and 0.67 in Cantillana and Enviciados, respectively. The results suggest that the use of a massive sampling parameter such as NDVI is a good indicator of the distribution of within-field yield variation. (Author)

  16. A novel stereotactic frame for real PET-guided biopsies: A preclinical proof-of-concept.

    Science.gov (United States)

    Cortes-Rodicio, J; Sanchez-Merino, G; Garcia-Fidalgo, M A; Tobalina-Larrea, I

    2017-09-01

    To design, build and test a stereotactic device that allows PET image-guided biopsies to be performed. An initial prototype consisting of four main pieces, one of which contains radioactive markers to make it visible in the PET images, was built using a 3D printer. Once the device is mounted, a spherical coordinate system is built with the entrance needle point in the skin as the origin of coordinates. Two in-house software programs, namely getCoord.ijm, which obtains the spherical coordinates of the tumour tissue to be biopsied, and getNeedle.ijm, which virtualizes the inner needle tip once the puncture has taken place, were written. This prototype was tested on an FDG-doped phantom to characterize both the accuracy of the system and the procedure time. Up to 11 complete biopsy procedures were conducted. The mean total procedure time was less than 20min, which is less than the procedure time of conventional standard CT-guided biopsies. The overall accuracy of the system was found to be 5.0±1.3mm, which outperforms the criterion used in routine clinical practice when targeting tumours with a diameter of 10mm. A stereotactic frame to conduct real PET image-guided biopsies has been designed and built. A proof-of-concept was performed to characterize the system. The procedure time and accuracy of the system were found to meet the current needs of physicians performing biopsies. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  17. RT-06GAMMA KNIFE SURGERY AFTER NAVIGATION-GUIDED ASPIRATION FOR CYSTIC METASTATIC BRAIN TUMORS

    Science.gov (United States)

    Chiba, Yasuyoshi; Mori, Kanji; Toyota, Shingo; Kumagai, Tetsuya; Yamamoto, Shota; Sugano, Hirofumi; Taki, Takuyu

    2014-01-01

    Metastatic brain tumors over 3 cm in diameter (volume of 14.1ml) are generally considered poor candidates for Gamma Knife surgery (GKS). We retrospectively assessed the method and efficacy of GKS for large cystic metastatic brain tumors after navigation-guided aspiration under local anesthesia. From September 2007 to April 2014, 38 cystic metastatic brain tumors in 32 patients (12 males, 20 females; mean age, 63.2 years) were treated at Kansai Rosai Hospital. The patients were performed navigation-guided cyst aspiration under local anesthesia, then at the day or the next day, were performed GKS and usually discharged on the day. The methods for preventing of leptomeningeal dissemination are following: 1) puncture from the place whose cerebral thickness is 1 cm or more; 2) avoidance of Ommaya reservoir implantation; and 3) placement of absorbable gelatin sponge to the tap tract. Tumor volume, including the cystic component, decreased from 25.4 ml (range 8.7-84.7 ml) to 11.4 ml (range 2.9-36.7 ml) following aspiration; the volume reduction was approximately 51.6%. Follow-up periods in the study population ranged from 0 to 24 months (median 3.5 months). The overall median survival was 6.7 months. There was no leptomeningeal dissemination related to the aspiration. One patient experienced radiation necrosis after GKS, one patient experienced re-aspiration by failure of aspiration, and two patients experienced surgical resections and one patient experienced re-aspiration by cyst regrowth after GKS. Long-term hospitalization is not desirable for the patients with brain metastases. In japan, Long-term hospitalization is required for surgical resection or whole brain radiation therapy, but only two days hospitalization is required for GKS after navigation-guided aspiration at our hospital. This GKS after navigation-guided aspiration is more effective and less invasive than surgical resection or whole brain radiation therapy.

  18. Evaluation of cholinesterase inhibitory and antioxidant activities of wild and cultivated samples of sage (Salvia fruticosa) by activity-guided fractionation.

    Science.gov (United States)

    Senol, Fatma Sezer; Orhan, Ilkay Erdogan; Erdem, Sinem Aslan; Kartal, Murat; Sener, Bilge; Kan, Yüksel; Celep, Ferhat; Kahraman, Ahmet; Dogan, Musa

    2011-11-01

    In European folk medicine, Salvia species have traditionally been used to enhance memory. In our previous study of 55 Salvia taxa, we explored significant anticholinesterase activity of cultivated S. fruticosa. In this study, we compared the inhibitory activity of dichloromethane, ethyl acetate, and ethanol extracts of 3 wild-grown samples and 1 cultivated sample of S. fruticosa against acetylcholinesterase and butyrylcholinesterase enzymes (which are associated with pathogenesis of Alzheimer's disease) by using the spectrophotometric Ellman method. Antioxidant activities were assessed by determining 2,2-diphenyl-1-picrylhydrazyl radical-scavenging activity, iron-chelating capacity, and ferric-reducing antioxidant power. The dichloromethane extract of the cultivated sample was then subjected to fractionation by using open column chromatography and medium-pressure liquid chromatography to obtain the most active fraction by activity-guided fractionation. All fractions and subfractions were tested in the same manner, and inactive subfractions were discarded. The essential oil of the cultivated sample was analyzed by gas chromatography-mass spectrometry.

  19. Evaluation of an antimicrobial surgical glove to inactivate live human immunodeficiency virus following simulated glove puncture.

    Science.gov (United States)

    Edmiston, Charles E; Zhou, S Steve; Hoerner, Pierre; Krikorian, Raffi; Krepel, Candace J; Lewis, Brian D; Brown, Kellie R; Rossi, Peter J; Graham, Mary Beth; Seabrook, Gary R

    2013-02-01

    Percutaneous injuries associated with cutting instruments, needles, and other sharps (eg, metallic meshes, bone fragments, etc) occur commonly during surgical procedures, exposing members of surgical teams to the risk for contamination by blood-borne pathogens. This study evaluated the efficacy of an innovative integrated antimicrobial glove to reduce transmission of the human immunodeficiency virus (HIV) following a simulated surgical-glove puncture injury. A pneumatically activated puncturing apparatus was used in a surgical-glove perforation model to evaluate the passage of live HIV-1 virus transferred via a contaminated blood-laden needle, using a reference (standard double-layer glove) and an antimicrobial benzalkonium chloride (BKC) surgical glove. The study used 2 experimental designs. In method A, 10 replicates were used in 2 cycles to compare the mean viral load following passage through standard and antimicrobial gloves. In method B, 10 replicates were pooled into 3 aliquots and were used to assess viral passage though standard and antimicrobial test gloves. In both methods, viral viability was assessed by observing the cytopathic effects in human lymphocytic C8166 T-cell tissue culture. Concurrent viral and cell culture viability controls were run in parallel with the experiment's studies. All controls involving tissue culture and viral viability were performed according to study design. Mean HIV viral loads (log(10)TCID(50)) were significantly reduced (P reduction (log reduction and percent viral reduction) of the HIV virus ranged from 1.96 to 2.4 and from 98.9% to 99.6%, respectively, following simulated surgical-glove perforation. Sharps injuries in the operating room pose a significant occupational risk for surgical practitioners. The findings of this study suggest that an innovative antimicrobial glove was effective at significantly (P < .01) reducing the risk for blood-borne virus transfer in a model of simulated glove perforation. Copyright

  20. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    Science.gov (United States)

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  1. Minimal invasive puncture and drainage versus endoscopic surgery for spontaneous intracerebral hemorrhage in basal ganglia

    Directory of Open Access Journals (Sweden)

    Li Z

    2017-01-01

    Full Text Available Zhihong Li,1,* Yuqian Li,1,* Feifei Xu,2,* Xi Zhang,3 Qiang Tian,4 Lihong Li1 1Department of Neurosurgery, Tangdu Hospital, 2Department of Foreign Languages, 3Department of Biomedical Engineering, 4Department of Radiology, Tangdu Hospital, The Fourth Military Medical University, Xi’an, Shaanxi Province, People’s Republic of China *These authors contributed equally to this work Abstract: Two prevalent therapies for the treatment of spontaneous intracerebral hemorrhage (ICH in basal ganglia are, minimally invasive puncture and drainage (MIPD, and endoscopic surgery (ES. Because both surgical techniques are of a minimally invasive nature, they have attracted greater attention in recent years. However, evidence comparing the curative effect of MIPD and ES has been uncertain. The indication for MIPD or ES has been uncertain till now. In the present study, 112 patients with spontaneous ICH in basal ganglia who received MIPD or ES were reviewed retrospectively. Baseline parameters prior to the operation, evacuation rate (ER, perihematoma edema, postoperative complications, and rebleeding incidences were collected. Moreover, 1-year postictus, the long-term functional outcomes of patients with regard to hematoma volume (HV or Glasgow Coma Scale (GCS score were judged, respectively, by the case fatality, Glasgow Outcome Scale (GOS, Barthel Index (BI, and modified Rankin Scale (mRS. The ES group had a higher ER than the MIPD group on postoperative day 1. The MIPD group had fewer adverse outcomes, which included less perihematoma edema, anesthetic time, and blood loss, than the ES group. The functional outcomes represented by GOS, BI, and mRS were better in the MIPD group than in the ES group for patients with HV 30–60 mL or GCS score 9–14. These results indicate that ES is more effective in evacuating hematoma in basal ganglia, while MIPD is less invasive than ES. Patients with HV 30–60 mL or GCS score 9–14 may benefit more from the MIPD

  2. CT-guided transgluteal biopsy for systematic sampling of the prostate in patients without rectal access: a 13-year single-center experience.

    Science.gov (United States)

    Olson, Michael C; Atwell, Thomas D; Mynderse, Lance A; King, Bernard F; Welch, Timothy; Goenka, Ajit H

    2017-08-01

    The purpose of our study was to examine the safety and diagnostic utility of transgluteal CT-guided prostate biopsy for prostate sampling in patients without rectal access. Seventy-three biopsies were performed in 65 patients over a 13-year period (2002-2015). Mean prostate-specific antigen (PSA) at biopsy was 7.8 ng/mL (range 0.37-31.5). Electronic medical records were reviewed for procedural details and complications. Mean PSA and number of cores in malignant and benign cohorts were compared with Student's t test. Technical success rate was 97.3% (71/73; mean cores 8, range 3-28). Of these, 43.6% (31/71) yielded malignancy (mean Gleason score 7, range 6-10) and 56.3% (40/71) yielded benign tissue. The only complication was an asymptomatic periprostatic hematoma (1/73; 1.4%). In 14 patients who underwent surgery, Gleason scores were concordant in 71.4% (10/14) and discordant in 28.6% (4/14; Gleason 6 on biopsy but Gleason 7 on surgical specimen). Mean effective radiation dose was 18.5 mSv (median 15.0, range 4.4-86.2). There was no significant difference in either mean PSA (p = 0.06) or number of core specimens (p = 0.33) between malignant and benign cohorts. CT-guided transgluteal prostate biopsy is highly safe and reliable for the detection of prostate cancer in men without rectal access. • Prostate cancer detection in men without rectal access is challenging. • CT-guided transgluteal prostate biopsy is safe and effective in these patients. • CT-guided biopsy may be particularly effective in diagnosing high-grade prostate cancer. • Unilateral CT-guided biopsy may be effective in patients with focal lesions. • The radiation exposure with this technique is acceptable.

  3. Utilizing the Flipped Classroom, Simulation-Based Mastery Learning and Group Learning to Teach and Evaluate Lumbar Puncture Skills

    Directory of Open Access Journals (Sweden)

    Amanda Crichlow

    2018-01-01

    Full Text Available Audience: This lumbar puncture curriculum was developed and implemented to educate and evaluate incoming intern Emergency Medicine (EM residents. This curriculum can also be used to educate and evaluate senior medical students and senior residents. Introduction: Procedural competency is an important component of healthcare education. With the implementation of milestones, the need for valid assessment tools to determine procedural competency has increased. Simulation-based mastery learning (SBML with the incorporation of deliberate practice has been shown to be an effective way to teach and evaluate procedural skills.1-8 These studies, however, highlight one of the major barriers to successful integration of SBML into existing medical curricula: they require a significant investment of time. One reason for this is the performance of the pre-test evaluation of the learners’ procedure skills prior to commencement of training. Although necessary for research endeavors to evaluate curricula effectiveness, the need for pre-testing specifically on studies where the goal of the curricula is procedural competency, as measured by learners’ performance on the post-testing, has not been described. Consequently, we decided a more effective use of limited time was to allow our learners the opportunity for deliberate practice and conducting the post-test. Since the ultimate goal of our educational endeavors is to ensure that our learners achieve defined standards of performance, evaluation of their performance prior to training may not be necessary. Another reason for the significant time investment for SBML curricula is the utilization of individualized instruction with one facilitator providing corrective feedback to one learner. Although Cohen et al. reference the use of groups of learners for procedure training9, it is not explicitly delineated how the group instruction is conducted. In other disciplines, training team protocols such as dyad training

  4. Constraining neutron guide optimizations with phase-space considerations

    Energy Technology Data Exchange (ETDEWEB)

    Bertelsen, Mads, E-mail: mads.bertelsen@gmail.com; Lefmann, Kim

    2016-09-11

    We introduce a method named the Minimalist Principle that serves to reduce the parameter space for neutron guide optimization when the required beam divergence is limited. The reduced parameter space will restrict the optimization to guides with a minimal neutron intake that are still theoretically able to deliver the maximal possible performance. The geometrical constraints are derived using phase-space propagation from moderator to guide and from guide to sample, while assuming that the optimized guides will achieve perfect transport of the limited neutron intake. Guide systems optimized using these constraints are shown to provide performance close to guides optimized without any constraints, however the divergence received at the sample is limited to the desired interval, even when the neutron transport is not limited by the supermirrors used in the guide. As the constraints strongly limit the parameter space for the optimizer, two control parameters are introduced that can be used to adjust the selected subspace, effectively balancing between maximizing neutron transport and avoiding background from unnecessary neutrons. One parameter is needed to describe the expected focusing abilities of the guide to be optimized, going from perfectly focusing to no correlation between position and velocity. The second parameter controls neutron intake into the guide, so that one can select exactly how aggressively the background should be limited. We show examples of guides optimized using these constraints which demonstrates the higher signal to noise than conventional optimizations. Furthermore the parameter controlling neutron intake is explored which shows that the simulated optimal neutron intake is close to the analytically predicted, when assuming that the guide is dominated by multiple scattering events.

  5. Consistency in color parameters of a commonly used shade guide.

    Science.gov (United States)

    Tashkandi, Esam

    2010-01-01

    The use of shade guides to assess the color of natural teeth subjectively remains one of the most common means for dental shade assessment. Any variation in the color parameters of the different shade guides may lead to significant clinical implications. Particularly, since the communication between the clinic and the dental laboratory is based on using the shade guide designation. The purpose of this study was to investigate the consistency of the L∗a∗b∗ color parameters of a sample of a commonly used shade guide. The color parameters of a total of 100 VITAPAN Classical Vacuum shade guide (VITA Zahnfabrik, Bad Säckingen, Germany(were measured using a X-Rite ColorEye 7000A Spectrophotometer (Grand Rapids, Michigan, USA). Each shade guide consists of 16 tabs with different designations. Each shade tab was measured five times and the average values were calculated. The ΔE between the average L∗a∗b∗ value for each shade tab and the average of the 100 shade tabs of the same designation was calculated. Using the Student t-test analysis, no significant differences were found among the measured sample. There is a high consistency level in terms of color parameters of the measured VITAPAN Classical Vacuum shade guide sample tested.

  6. Robot-assisted biopsies in a high-field MRI system. First clinical results

    International Nuclear Information System (INIS)

    Schell, B.; Eichler, K.; Mack, M.G.; Mueller, C.; Kerl, J.M.; Beeres, M.; Thalhammer, A.; Vogl, T.J.; Zangos, S.; Czerny, C.

    2012-01-01

    Purpose: The purpose of this study was to examine the clinical use of MR-guided biopsies in patients with suspicious lesions using a new MR-compatible assistance system in a high-field MR system. Materials and Methods: Six patients with suspicious focal lesions in various anatomic regions underwent percutanous biopsy in a high-field MR system (1.5 T, Magnetom Espree, Siemens) using a new MR-compatible assistance system (Innomotion). The procedures were planned and guided using T1-weighted FLASH and TrueFISP sequences. A servopneumatic drive then moved the guiding arm automatically to the insertion point. An MRI compatible 15G biopsy system (Somatex) was introduced by a physician guided by the needle holder and multiple biopsies were performed using the coaxial technique. The feasibility, duration of the intervention and biopsy findings were analyzed. Results: The proposed new system allows accurate punctures in a high-field MR system. The assistance device did not interfere with the image quality, and guided the needle virtually exactly as planned. Histological examination could be conducted on every patient. The lesion was malignant in four cases, and an infectious etiology was diagnosed for the two remaining lesions. Regarding the differentiation of anatomical and pathological structures and position monitoring of the insertion needle, TrueFISP images are to be given preference. The average intervention time was 41 minutes. Lesions up to 15.4 cm beneath the skin surface were punctured. Conclusion: The proposed MR-guided assistance system can be successfully utilized in a high-field MR system for accurate punctures of even deep lesions in various anatomic regions. (orig.)

  7. Robot-assisted biopsies in a high-field MRI system. First clinical results; Roboterunterstuetzte Punktion in einem Hochfeld-Kernspintomografen. Erste klinische Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Schell, B.; Eichler, K.; Mack, M.G.; Mueller, C.; Kerl, J.M.; Beeres, M.; Thalhammer, A.; Vogl, T.J.; Zangos, S. [Frankfurt Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Czerny, C. [Frankfurt Univ. (Germany). Inst. fuer Unfall-, Hand- und Wiederherstellungschirurgie

    2012-01-15

    Purpose: The purpose of this study was to examine the clinical use of MR-guided biopsies in patients with suspicious lesions using a new MR-compatible assistance system in a high-field MR system. Materials and Methods: Six patients with suspicious focal lesions in various anatomic regions underwent percutanous biopsy in a high-field MR system (1.5 T, Magnetom Espree, Siemens) using a new MR-compatible assistance system (Innomotion). The procedures were planned and guided using T1-weighted FLASH and TrueFISP sequences. A servopneumatic drive then moved the guiding arm automatically to the insertion point. An MRI compatible 15G biopsy system (Somatex) was introduced by a physician guided by the needle holder and multiple biopsies were performed using the coaxial technique. The feasibility, duration of the intervention and biopsy findings were analyzed. Results: The proposed new system allows accurate punctures in a high-field MR system. The assistance device did not interfere with the image quality, and guided the needle virtually exactly as planned. Histological examination could be conducted on every patient. The lesion was malignant in four cases, and an infectious etiology was diagnosed for the two remaining lesions. Regarding the differentiation of anatomical and pathological structures and position monitoring of the insertion needle, TrueFISP images are to be given preference. The average intervention time was 41 minutes. Lesions up to 15.4 cm beneath the skin surface were punctured. Conclusion: The proposed MR-guided assistance system can be successfully utilized in a high-field MR system for accurate punctures of even deep lesions in various anatomic regions. (orig.)

  8. CT Guided biopsies of musculoskeletal lesions, radiological and pathologic correlation

    International Nuclear Information System (INIS)

    Hadzihasanovic, B.; Milisic, L.; Zuban, J.; Mujic, E.; Jahic, E.; Gjikolli, B.; Hasanovic, B.; Lincender-Cvijetic, L.; Jaganjac, S.

    2006-01-01

    Full text: The aim of the study is to overview our experiences in taking the CT guided biopsies of musculoskeletal lesions during the period of sixteen months, analysis of validity of samples taken and correlation with pathological findings. CT guided biopsies of musculoskeletal lesions were performed in 32 patients during the period of sixteen months (from December 2004 until March 2006). Age range was from 13 to 78 years. Majorities of the biopsies were performed with coaxial cutting needle system (14 G and 16 G) with introducers size 13 and 15 G. Bone biopsies were performed with Yamsidi needles in purpose of taking the bone cylinder. Majorities of the biopsies were performed under local anaesthesia except a thirteen years old child to whom CT guided biopsy of corpus Th 6 was performed under general anaesthesia. Two samples of tissues were sent in formalin solutions to Pathology Institute for pathological verification. In one case of musculoskeletal lesions CT guided biopsies didn't yield a representative tissue sample. We had high level of congruence between radiological and pathological findings; precise presented in the article. CT guided biopsies of musculoskeletal lesions are method of choice for pathologic verification of musculoskeletal lesions proving incomparable less risk compared to 'open' biopsy which requires operating theatre and general anaesthesia. Coaxial needle systems has shown as suitable for yielding representative tissue samples (two samples for each patient), and samples are also appropriate for immunohistochemical analysis

  9. Clinical experiences with application of soft laser puncture for the treatment of chronic painful status of locomotor apparatus in dogs

    International Nuclear Information System (INIS)

    Skalka, J.

    2008-01-01

    A zonal laser therapy in the region of particular dermatomas has been used in 6 dogs of different race, sex and age with different chronic painful states of locomotive organs in the frame of individual laser therapeutical regimens as well as laser puncture in a set of acupuncture points to be selected for each dog separately. Two dogs were assessed as cured. In two dogs the state has considerably improved and in two dogs the state has considerably improved with some parameters at a physiological level. (authors)

  10. Structure guided GANs

    Science.gov (United States)

    Cao, Feidao; Zhao, Huaici; Liu, Pengfei

    2017-11-01

    Generative adversarial networks (GANs) has achieved success in many fields. However, there are some samples generated by many GAN-based works, whose structure is ambiguous. In this work, we propose Structure Guided GANs that introduce structural similar into GANs to overcome the problem. In order to achieve our goal, we introduce an encoder and a decoder into a generator to design a new generator and take real samples as part of the input of a generator. And we modify the loss function of the generator accordingly. By comparison with WGAN, experimental results show that our proposed method overcomes largely sample structure ambiguous and can generate higher quality samples.

  11. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    Energy Technology Data Exchange (ETDEWEB)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua [University Hospital, University of Cologne, Department of Radiology, Cologne (Germany); Pfister, Roman [University Hospital, University of Cologne, Department of Internal Medicine III, Cologne (Germany); Deppe, Antje-Christin [University Hospital, University of Cologne, Department of Cardiothoracic Surgery, Cologne (Germany); Matoussevitch, Vladimir [University Hospital, University of Cologne, Department of Vascular Surgery, Cologne (Germany)

    2014-06-15

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  12. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    International Nuclear Information System (INIS)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua; Pfister, Roman; Deppe, Antje-Christin; Matoussevitch, Vladimir

    2014-01-01

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  13. Zeiss ΣIGMA VP-FE-SEM User Guide

    Science.gov (United States)

    User guide for analyzing carbon based nanomaterials on a Zeiss Sigma microscope. The guide includes helpful steps for sample preparation and loading. Specific topics utilizing the scanning electron microscope are instrumentation startup and imagining. A variety of detectors in...

  14. Reliability of conventional shade guides in teeth color determination.

    Science.gov (United States)

    Todorović, Ana; Todorović, Aleksandar; Gostović, Aleksandra Spadijer; Lazić, Vojkan; Milicić, Biljana; Djurisić, Slobodan

    2013-10-01

    Color matching in prosthodontic therapy is a very important task because it influences the esthetic value of dental restorations. Visual shade matching represents the most frequently applied method in clinical practice. Instrumental measurements provide objective and quantified data in color assessment of natural teeth and restorations. In instrumental shade analysis, the goal is to achieve the smallest deltaE value possible, indicating the most accurate shade match. The aim of this study was to evaluate the reliability of commercially available ceramic shade guides. VITA Easyshade spectrophotometer (VITA, Germany) was used for instrumental color determination. Utilizing this device, color samples of ten VITA Classical and ten VITA 3D - Master shade guides were analyzed. Each color sample from all shade guides was measured three times and the basic parameters of color quality were examined: deltaL, deltaC, deltaH, deltaE, deltaElc. Based on these parameters spectrophotometer marks the shade matching as good, fair or adjust. After performing 1,248 measurements of ceramic color samples, frequency of evaluations adjust, fair and good were statistically significantly different between VITA Classical and VITA 3D Master shade guides (p = 0.002). There were 27.1% cases scored as adjust, 66.3% as fair and 6.7% as good. In VITA 3D - Master shade guides 30.9% cases were evaluated as adjust, 66.4% as fair and 2.7% cases as good. Color samples from different shade guides, produced by the same manufacturer, show variability in basic color parameters, which once again proves the lack of precision and nonuniformity of the conventional method.

  15. Network and adaptive sampling

    CERN Document Server

    Chaudhuri, Arijit

    2014-01-01

    Combining the two statistical techniques of network sampling and adaptive sampling, this book illustrates the advantages of using them in tandem to effectively capture sparsely located elements in unknown pockets. It shows how network sampling is a reliable guide in capturing inaccessible entities through linked auxiliaries. The text also explores how adaptive sampling is strengthened in information content through subsidiary sampling with devices to mitigate unmanageable expanding sample sizes. Empirical data illustrates the applicability of both methods.

  16. Office-based narrow band imaging-guided flexible laryngoscopy tissue sampling: A cost-effectiveness analysis evaluating its impact on Taiwanese health insurance program

    OpenAIRE

    Fang, Tuan-Jen; Li, Hsueh-Yu; Liao, Chun-Ta; Chiang, Hui-Chen; Chen, I-How

    2015-01-01

    Narrow band imaging (NBI)-guided flexible laryngoscopy tissue sampling for laryngopharyngeal lesions is a novel technique. Patients underwent the procedure in an office-based setting without being sedated, which is different from the conventional technique performed using direct laryngoscopy. Although the feasibility and effects of this procedure were established, its financial impact on the institution and Taiwanese National Health Insurance program was not determined. Methods: This is a ...

  17. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

    International Nuclear Information System (INIS)

    Chan, Gabriel; Quek, Lawrence Hwee Han; Tan, Glenn Leong Wei; Pua, Uei

    2016-01-01

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

  18. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Gabriel, E-mail: dr.changabriel@gmail.com; Quek, Lawrence Hwee Han, E-mail: lawrence-quek@ttsh.com.sg [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore); Tan, Glenn Leong Wei, E-mail: glenn-tan@ttsh.com.sg [Tan Tock Seng Hospital, Department of General Surgery (Singapore); Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2016-07-15

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

  19. The effect of intravenous propofol on the incidence of post-dural puncture headache following spinal anesthesia in cesarean section

    Directory of Open Access Journals (Sweden)

    Parisa Golfam

    2016-09-01

    Full Text Available Introduction: Post Dural puncture headache is still a common complication among young women undergone cesarean section, although use of small size spinal needles reduced its prevalence. Several methods have been suggested for prevention and treatment of this side effect; such as complete bed rest, hydration, non-opioid analgesics, caffeine, codeine, which none of them proved to be totally effective. The last option would be epidural blood patch, if headache persist. The aim of this study was evaluation the efficacy of intravenous propofol on post dural puncture headache incidence after cesarean section. Methods: In a randomized clinical trial 120 patients aged 18-45 years old in American Society of Anesthesiologist (ASA class I or II, who had no history of headache, analgesic consumption, substance abuse and drug addiction, candidate for elective cesarean section, were randomly assigned into intervention (propofol and control groups. The anesthesia method for both groups was precisely the same. After spinal anesthesia in the first group 30µg/kg/min of intravenous propofol have been infused slowly. Then at 1, 6, 18, 24 hours and 2nd to 7th days after surgery, anesthesiologist asked groups for presence or absence of headache. The data analyzed with SPSS 16.0 software. Results: Headache incidence rate in the group who receiving propofol was significantly reduced (P.V=0.001. Conclusion: This study showed that 30µg/kg/min of intravenous propofol caused reduced the incidence of post spinal headache in young women undergone elective cesarean section.

  20. Myelography in achondroplasia: value of a lateral C1-2 puncture and non-ionic, water-soluble contrast medium

    International Nuclear Information System (INIS)

    Suss, R.A.; Udvarhelyi, G.B.; Wang, H.; Kumar, A.J.; Zinreich, S.J.; Rosenbaum, A.E.

    1983-01-01

    Because of technical difficulties and diagnostic limitations encountered with other myelographic techniques in patients with achondroplasia, the authors employed a lateral C1-2 puncture and non-ionic, water-soluble contrast medium in 18 achondroplastic patients with spinal compression (21 procedures). This technique proved most appropriate for identifying the upper limit of degenerative osteophytes causing exacerbation of congenital spinal stenosis, which is crucial in planning decompressive surgery. A potentially important additional finding was the presence of degenerative lower cervical spine disease in the majority of patients. There were no serious complications. The authors recommend this technique as safe and effective in achondroplastic patients with severe congenital spinal stenosis

  1. Benefit of Chest Ultrasonography in the Diagnosis of Peripheral Thoracic Lesions in an Interventional Pulmonology Unit.

    Science.gov (United States)

    García-Ortega, Alberto; Briones-Gómez, Andrés; Fabregat, Sandra; Martínez-Tomás, Raquel; Martínez-García, Miguel Ángel; Cases, Enrique

    2016-05-01

    The use of ultrasound in peripheral thoracic lesions offers advantages over other radiological guiding methods. This diagnostic procedure has been applied in most studies published by radiologists. Our aim was to determine the diagnostic efficacy of percutaneous ultrasound-guided punctures and biopsies of peripheral thoracic lesions performed by pulmonologists. A retrospective analysis of 58 patients who underwent real-time ultrasound-guided transthoracic punctures and biopsy of peripheral thoracic lesions between March 2011 and September 2014 in the pulmonology department of our hospital. Cases were classified into the following diagnostic categories: malignant, benign and non-diagnostic (non-specific benign without evidence of malignancy and insufficient specimen). A conclusive diagnosis was obtained in 47 procedures (81%), of which 13 (22.4%) were specific benign lesions and 34 (58.6%) cancers. In the remaining 11 (19%) patients, a non-diagnostic result was obtained [non-specific benign in 5 cases (8.6%) and insufficient specimen in 6 (10.3%)]. Sensitivity was 75.6%, negative predictive value was 54.2%, specificity and positive predictive value were 100%, and diagnostic accuracy was 81%. Excluding procedures with insufficient specimens, the results were 87.2%, 72.3%, 100%, 100% and 90.4% respectively. There were no serious complications. Percutaneous ultrasound-guided puncture and biopsy in the diagnosis of peripheral thoracic lesions performed by pulmonologists is a safe procedure with high diagnostic accuracy. We achieved similar results to those previously obtained by radiologists. Copyright © 2015 SEPAR. Published by Elsevier Espana. All rights reserved.

  2. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    Energy Technology Data Exchange (ETDEWEB)

    Nattenmüller, Johanna, E-mail: johanna.nattenmueller@med.uni-heidelberg.de; Filsinger, Matthias, E-mail: Matthias_filsinger@web.de; Bryant, Mark, E-mail: mark.bryant@med.uni-heidelberg.de; Stiller, Wolfram, E-mail: Wolfram.Stiller@med.uni-heidelberg.de; Radeleff, Boris, E-mail: boris.radeleff@med.uni-heidelberg.de; Grenacher, Lars, E-mail: lars.grenacher@med.uni-heidelberg.de; Kauczor, Hans-Ullrich, E-mail: hu.kauczor@med.uni-heidelberg.de; Hosch, Waldemar, E-mail: waldemar.hosch@urz.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  3. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    International Nuclear Information System (INIS)

    Nattenmüller, Johanna; Filsinger, Matthias; Bryant, Mark; Stiller, Wolfram; Radeleff, Boris; Grenacher, Lars; Kauczor, Hans-Ullrich; Hosch, Waldemar

    2014-01-01

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only

  4. MRI follow-up after concordant, histologically benign diagnosis of breast lesions sampled by MRI-guided biopsy.

    Science.gov (United States)

    Li, Jie; Dershaw, D David; Lee, Carol H; Kaplan, Jennifer; Morris, Elizabeth A

    2009-09-01

    Follow-up MRI can be useful to confirm a benign diagnosis after MRI-guided breast biopsy. This retrospective study was undertaken to evaluate appropriate timing and imaging interpretation for the initial follow-up MRI when a benign, concordant histology is obtained using MRI-guided breast biopsy. Retrospective review was performed of 177 lesions visualized only by MRI in 172 women who underwent 9-gauge, vacuum-assisted core biopsy and marker placement with imaging-concordant benign histology. All underwent follow-up MRI within 12 months. Timing of the follow-up study, change in size, results of second biopsy if performed, and distance of localizing marker to the lesion on the follow-up study were recorded. At initial follow-up, 155 lesions were decreased or gone, 14 lesions were stable, and eight were enlarged. Seventeen (9.6%, 17/177) lesions underwent a second biopsy, including six enlarging, 10 stable, and one decreasing. Of these, four were malignant. Enlargement was seen in two carcinomas at 6 and 12 months. Two carcinomas, one stable at 2 months and another stable at 3 and 11 months, were rebiopsied because of suspicion of a missed lesion in the former and worrisome mammographic and sonographic changes in the latter. The distance of the marker from the lesion on follow-up did not correlate with biopsy accuracy. Follow-up MRI did not detect missed cancers because of lesion enlargement before 6 months after biopsy; two of four missed cancers were stable. The localizing marker can deploy away from the target despite successful sampling.

  5. Utility Energy Services Contracts Guide

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-09-01

    The UESC Guide is a compilation of samples and templates developed as a resource to help contracting officers implement task orders for UESCs under existing U.S. General Services Administration areawide contracts.

  6. CHANGE DETECTION VIA SELECTIVE GUIDED CONTRASTING FILTERS

    Directory of Open Access Journals (Sweden)

    Y. V. Vizilter

    2017-05-01

    Full Text Available Change detection scheme based on guided contrasting was previously proposed. Guided contrasting filter takes two images (test and sample as input and forms the output as filtered version of test image. Such filter preserves the similar details and smooths the non-similar details of test image with respect to sample image. Due to this the difference between test image and its filtered version (difference map could be a basis for robust change detection. Guided contrasting is performed in two steps: at the first step some smoothing operator (SO is applied for elimination of test image details; at the second step all matched details are restored with local contrast proportional to the value of some local similarity coefficient (LSC. The guided contrasting filter was proposed based on local average smoothing as SO and local linear correlation as LSC. In this paper we propose and implement new set of selective guided contrasting filters based on different combinations of various SO and thresholded LSC. Linear average and Gaussian smoothing, nonlinear median filtering, morphological opening and closing are considered as SO. Local linear correlation coefficient, morphological correlation coefficient (MCC, mutual information, mean square MCC and geometrical correlation coefficients are applied as LSC. Thresholding of LSC allows operating with non-normalized LSC and enhancing the selective properties of guided contrasting filters: details are either totally recovered or not recovered at all after the smoothing. These different guided contrasting filters are tested as a part of previously proposed change detection pipeline, which contains following stages: guided contrasting filtering on image pyramid, calculation of difference map, binarization, extraction of change proposals and testing change proposals using local MCC. Experiments on real and simulated image bases demonstrate the applicability of all proposed selective guided contrasting filters. All

  7. Guide to preparing SAND reports. Revised

    Energy Technology Data Exchange (ETDEWEB)

    Locke, T.K. [ed.

    1996-04-01

    This guide contains basic information needed to produce a SAND report. Its guidelines reflect DOE regulation and Sandia policy. The guide includes basic writing instructions in an annotated sample report; guidance for organization, format, and layout of reports produced by line organizations; and information about conference papers, journal articles, and brochures. The appendixes contain sections on Sandia`s preferred usage, equations, references, copyrights and permissions, and publishing terms.

  8. Lumbar Puncture Alleviates Chorea in a Patient with Huntington’s Disease and Normal Pressure Hydrocephalus

    Directory of Open Access Journals (Sweden)

    Peyman Shirani

    2009-01-01

    Full Text Available A 44-year-old African-American male was admitted to our hospital after a suicide attempt. He had depression, poor cognitive function, choreiform movements, difficulty pronouncing words, and difficulty walking. His symptoms had worsened markedly over several months. Chorea lead to genetic testing that confirmed a diagnosis of Huntington Disease (HD. A CT scan of the head showed wider ventricles than is typical of HD. The head CT and gait change suggested normal pressure hydrocephalus (NPH. Lumbar puncture (LP led to improved neuropsychologic test scores and walking thereby supporting the diagnosis of NPH. Surprisingly, the LP also led to an 80% improvement of chorea. There are two other reports of an association between HD and NPH. NPH should be considered in HD patients with atypical symptoms, such as the inability to walk or rapid progression, as its treatment may lead to improved cognition, gait, and chorea.

  9. Sea Ice as a Sink for CO2 and Biogeochemical Material: a Novel Sampling Method and Astrobiological Applications

    Science.gov (United States)

    Wilner, J.; Hofmann, A.; Hand, K. P.

    2017-12-01

    Accurately modelling the intensification of greenhouse gas effects in the polar regions ("polar amplification") necessitates a thorough understanding of the geochemical balance between atmospheric, sea ice, and oceanic layers. Sea ice is highly permeable to CO2 and therefore represents a major sink of oceanic CO2 in winter and of atmospheric CO2 in summer, sinks that are typically either poorly constrained in or fully absent from global climate models. We present a novel method for sampling both trapped and dissolved gases (CO2, CH4 and δ13CH4) in sea ice with a Picarro 2132-i Methane Analyzer, taking the following sampling considerations into account: minimization of water and air contamination, full headspace sampling, prevention of inadvertent sample bag double-puncturing, and ease of use. This method involves melting of vacuum-sealed ice cores to evacuate trapped gases to the headspace and sampling the headspace gas with a blunt needle sheathed by a beveled puncturing needle. A gravity catchment tube prevents input of dangerous levels of liquid water to the Picarro cavity. Subsequent ultrasonic degassing allows for dissolved gas measurement. We are in the process of using this method to sample gases trapped and dissolved in Arctic autumn sea ice cores and atmospheric samples collected during the 2016 Polarstern Expedition and during a May 2017 field campaign north of Barrow, Alaska. We additionally employ this method, together with inductively coupled plasma mass spectrometry (ICP-MS), to analyze the transfer of potential biogeochemical signatures of underlying hydrothermal plumes to sea ice. This has particular relevance to Europa and Enceladus, where hypothetical hydrothermal plumes may deliver seafloor chemicals to the overlying ice shell. Hence, we are presently investigating the entrainment of methane and other hydrothermal material in sea ice cores collected along the Gakkel Ridge that may serve as biosignatures of methanogenic organisms in seafloor

  10. Emergent radiologically guided drainage of large pericardial effusions

    International Nuclear Information System (INIS)

    Hartz, W.H.; Gatenby, R.A.; Kessler, H.B.

    1987-01-01

    The authors drained eight pericardial effusions on an emergency basis because of profound symptoms of pericardial tamponade. The etiology of the pericardial was metastatic disease in all eight cases. US of the subxyphoid region allowed definition of an optimal percutaneous approach. The pericardium was initially punctured with a 22-gauge needle, followed by tract dilation over a wire, which allowed ultimate placement of either an 8.4-F or 10-F nephrostomy catheter. Some 500 - 1,500 ml of bloody fluid drained from the pericardial space within minutes, and a total of 2 - 4 L over the next 4 days. No significant arrhythmias or immediate hypotensive episodes were observed. Six of the patients were successfully treated with sclerosis of the pericardium by injection of tetracyline into the pericardial catheter before it was removed. No recurrent effusions have been observed in any of these patients. Two patients died, one of unsuspected cerebral edema and uncal herniation and one of intractable congestive heart failure. At autopsy, the pericardial catheter was properly positioned with no significant remaining fluid. Echocardiograms were falsely normal in two patients, but CT findings were uniformly diagnostic. Radiologically guided drainage of large pericardial effusions appears to be a safe and effective technique for the treatment of pericardial tamponade from metastatic effusions. This technique is an alternative to the usual surgical intervention and does not require general anesthesia

  11. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    Science.gov (United States)

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  12. MR image reconstruction via guided filter.

    Science.gov (United States)

    Huang, Heyan; Yang, Hang; Wang, Kang

    2018-04-01

    Magnetic resonance imaging (MRI) reconstruction from the smallest possible set of Fourier samples has been a difficult problem in medical imaging field. In our paper, we present a new approach based on a guided filter for efficient MRI recovery algorithm. The guided filter is an edge-preserving smoothing operator and has better behaviors near edges than the bilateral filter. Our reconstruction method is consist of two steps. First, we propose two cost functions which could be computed efficiently and thus obtain two different images. Second, the guided filter is used with these two obtained images for efficient edge-preserving filtering, and one image is used as the guidance image, the other one is used as a filtered image in the guided filter. In our reconstruction algorithm, we can obtain more details by introducing guided filter. We compare our reconstruction algorithm with some competitive MRI reconstruction techniques in terms of PSNR and visual quality. Simulation results are given to show the performance of our new method.

  13. Combined ultrasound and fluoroscopy guided port catheter implantation-High success and low complication rate

    International Nuclear Information System (INIS)

    Gebauer, Bernhard; El-Sheik, Michael; Vogt, Michael; Wagner, Hans-Joachim

    2009-01-01

    Purpose: To evaluate peri-procedural, early and late complications as well as patients' acceptance of combined ultrasound and fluoroscopy guided radiological port catheter implantation. Materials and methods: In a retrospective analysis, all consecutive radiological port catheter implantations (n = 299) between August 2002 and December 2004 were analyzed. All implantations were performed in an angio suite under analgosedation and antibiotic prophylaxis. Port insertion was guided by ultrasonographic puncture of the jugular (n = 298) or subclavian (n = 1) vein and fluoroscopic guidance of catheter placement. All data of the port implantation had been prospectively entered into a database for interventional radiological procedures. To assess long-term results, patients, relatives or primary physicians were interviewed by telephone; additional data were generated from the hospital information system. Patients and/or the relatives were asked about their satisfaction with the port implantion procedure and long-term results. Results: The technical success rate was 99% (298/299). There were no major complications according to the grading system of SIR. A total of 23 (0.33 per 1000 catheter days) complications (early (n = 4), late (n = 19)) were recorded in the follow-period of a total of 72,727 indwelling catheter days. Infectious complications accounted for 0.15, thrombotic for 0.07 and migration for 0.04 complications per 1000 catheter days. Most complications were successfully treated by interventional measures. Twelve port catheters had to be explanted due to complications, mainly because of infection (n = 9). Patients' and relatives' satisfaction with the port catheter system was very high, even if complications occurred. Conclusion: Combined ultrasound and fluoroscopy guided port catheter implantation is a very safe and reliable procedure with low peri-procedural, early and late complication rate. The intervention achieves very high acceptance by the patients and

  14. Shorter Duration of Post-Operative Antibiotics for Cecal Ligation and Puncture Does Not Increase Inflammation or Mortality.

    Directory of Open Access Journals (Sweden)

    Kendra N Iskander

    Full Text Available Antimicrobial therapy for sepsis has beneficial effects, but prolonged use fosters emergence of resistant microorganisms, increases cost, and secondary infections. We tested whether 3 days versus 5 days of antibiotics in the murine model of cecal ligation and puncture (CLP negatively influences outcomes. Following CLP mice were randomized to receive the antibiotic imipenem-cilastatin (25mg/kg in dextrose 5% in Lactated Ringer's solution every 12 hours for either three or five days. Serial monitoring over 28 days included body weight, temperature, pulse oximetry, and facial vein sampling for hematological analysis and glucose. A separate group of mice were euthanized on post-CLP day 5 to measure cytokines and peritoneal bacterial counts. The first study examined no antimicrobial therapy and demonstrated that antibiotics significantly improved survival compared to fluids only (p = 0.004. We next tested imipenem-cilastatin therapy for 3 days versus 5 days. Body weight, temperature, glucose, and pulse oximetry measurements remained generally consistent between both groups as did the hematological profile. Pro-inflammatory plasma cytokines were comparable between both groups for IL-6, IL-1β, MIP-2 and anti-inflammatory cytokines IL-10, and TNF SRI. At 5 days post-CLP, i.e. 2 days after the termination of antibiotics in the 3 day group, there were no differences in the number of peritoneal bacteria. Importantly, shortening the course of antibiotics by 40% (from 5 days to 3 days did not decrease survival. Our results indicate that reducing the duration of broad-spectrum antibiotics in murine sepsis did not increase inflammation or mortality.

  15. Acesso venoso central guiado por ultrassom: qual a evidência? Ultrasound-guided central venous catheterization: what is the evidence?

    Directory of Open Access Journals (Sweden)

    Felippe Leopoldo Dexheimer Neto

    2011-06-01

    access, ultrasonography, and adults. The search was conducted on September 24, 2010, and selected meta-analyses, randomized clinical trials and reviews, retrieving 291 papers. The 21 most important papers were analyzed in this review. The internal jugular vein is the most studied ultrasound-guided puncture site, with meta-analysis showing lower relative risks of failure and complications. In addition, the largest available randomized clinical trial demonstrated a reduced central venous catheter-associated blood stream infection rate. There are few studies involving subclavian vein puncture; however, ultrasound was shown to be beneficial in two meta-analyses (however, with small numbers of patients. Regarding the femoral venous site, only one randomized clinical trial (20 patients was identified, showing positive findings. In a British cost-effectiveness study, ultrasound use lead to resource savings for different sites of venous puncture. There is strong evidence for ultrasound benefit for internal jugular vein puncture. Although the method appears attractive for the other sites, the data are not sufficient to support any recommendation.

  16. Users guide to the inelastic rotor spectrometer (IRS)

    International Nuclear Information System (INIS)

    Bunce, L.J.

    1987-11-01

    The paper is a users guide to the inelastic rotor spectrometer installed on the Harwell 136 Mev electron linear accelerator HELIOS. The spectrometer is designed to measure neutron inelastic scattering for energy transfers from 50 meV to 400 meV and covering a range of Q values from 1 to 15 A 0-1 . The guide contains a description of:- time-of-flight scales, run and sample changer control units, sample environment, detectors, rotor system, 600 Hz operation of rotor, a run, and data processing. (U.K.)

  17. Optimizing the triple-axis spectrometer PANDA at the MLZ for small samples and complex sample environment conditions

    Science.gov (United States)

    Utschick, C.; Skoulatos, M.; Schneidewind, A.; Böni, P.

    2016-11-01

    The cold-neutron triple-axis spectrometer PANDA at the neutron source FRM II has been serving an international user community studying condensed matter physics problems. We report on a new setup, improving the signal-to-noise ratio for small samples and pressure cell setups. Analytical and numerical Monte Carlo methods are used for the optimization of elliptic and parabolic focusing guides. They are placed between the monochromator and sample positions, and the flux at the sample is compared to the one achieved by standard monochromator focusing techniques. A 25 times smaller spot size is achieved, associated with a factor of 2 increased intensity, within the same divergence limits, ± 2 ° . This optional neutron focusing guide shall establish a top-class spectrometer for studying novel exotic properties of matter in combination with more stringent sample environment conditions such as extreme pressures associated with small sample sizes.

  18. Elementary Science Resource Guide.

    Science.gov (United States)

    Texas Education Agency, Austin. Div. of Curriculum Development.

    This guide for elementary teachers provides information on getting ideas into action, designing and implementing the right situation, ways in which to evaluate science process activities with students, and seven sample units. The units cover using the senses, magnets, forces, weather forecasting, classification of living things, and the physical…

  19. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material

    International Nuclear Information System (INIS)

    Degirmenci, B.; Haktanir, A.; Albayrak, R.; Acar, M.; Sahin, D.A.; Sahin, O.; Yucel, A.; Caliskan, G.

    2007-01-01

    Aim: To evaluate the effects of sonographic characteristics of thyroid nodules, the diameter of needle used for sampling, and sampling technique on obtaining sufficient cytological material (SCM). Materials and methods: We performed sonography-guided fine-needle biopsy (FNB) in 232 solid thyroid nodules. Size-, echogenicity, vascularity, and localization of all nodules were evaluated by Doppler sonography before the biopsy. Needles of size 20, 22, and 24 G were used for biopsy. The biopsy specimen was acquired using two different methods after localisation. In first method, the needle tip was advanced into the nodule in various positions using a to-and-fro motion whilst in the nodule, along with concurrent aspiration. In the second method, the needle was advanced vigorously using a to-and-fro motion within the nodule whilst being rotated on its axis (capillary-action technique). Results: The mean nodule size was 2.1 ± 1.3 cm (range 0.4-7.2 cm). SCM was acquired from 154 (66.4%) nodules by sonography-guided FNB. In 78 (33.6%) nodules, SCM could not be collected. There was no significant difference between nodules with different echogenicity and vascularity for SCM. Regarding the needle size, the lowest rate of SCM was obtained using 20 G needles (56.6%) and the highest rate of adequate material was obtained using 24 G needles (82.5%; p = 0.001). The SCM rate was 76.9% with the capillary-action technique versus 49.4% with the aspiration technique (p < 0.001). Conclusion: Selecting finer needles (24-25 G) for sonography-guided FNB of thyroid nodules and using the capillary-action technique decreased the rate of inadequate material in cytological examination

  20. Hearing aid user guides: suitability for older adults.

    Science.gov (United States)

    Caposecco, Andrea; Hickson, Louise; Meyer, Carly

    2014-02-01

    The aim of this study was to analyse the content, design, and readability of printed hearing aid user guides to determine their suitability for older adults, who are the main users of hearing aids. Hearing aid user guides were assessed using four readability formulae and a standardized tool to assess content and design (SAM - Suitability Assessment of Materials). A sample of 36 hearing aid user guides (four user guides from nine different hearing aid manufacturers) were analysed. Sixty nine percent of user guides were rated 'not suitable' and 31% were rated 'adequate' for their suitability. Many scored poorly for scope, vocabulary, aspects of layout and typography, and learning stimulation and motivation. The mean reading grade level for all user guides was grade 9.6 which is too high for older adults. The content, design, and readability of hearing aid user guides are not optimal for older adults and thus may serve as a barrier to successful hearing aid outcomes for this population.

  1. MRI-guided vacuum-assisted breast biopsy: comparison with stereotactically guided and ultrasound-guided techniques

    Energy Technology Data Exchange (ETDEWEB)

    Imschweiler, Thomas; Freiwald, Bianka; Kubik-Huch, Rahel A. [Kantonspital Baden AG, Institute for Radiology, Baden (Switzerland); Haueisen, Harald [Kantonspital Aarau AG, Institute for Radiology, Aarau (Switzerland); Kampmann, Gert [Clinica Sant' Anna, Lugano, Sorengo (Switzerland); Rageth, Luzi [Adjumed Services AG, Zurich (Switzerland); Seifert, Burkhardt [Institute for Social and Preventive Medicine, University of Zurich, Division of Biostatistics, Zuerich (Switzerland); Rageth, Christoph [Breast Centre, Zurich (Switzerland)

    2014-01-15

    To analyse the development of MRI-guided vacuum-assisted biopsy (VAB) in Switzerland and to compare the procedure with stereotactically guided and ultrasound-guided VAB. We performed a retrospective analysis of VABs between 2009 and 2011. A total of 9,113 VABs were performed. Of these, 557 were MRI guided. MRI-guided VAB showed the highest growth rate (97 %) of all three procedures. The technical success rates for MRI-guided, stereotactically guided and ultrasound-guided VAB were 98.4 % (548/557), 99.1 % (5,904/5,960) and 99.6 % (2,585/2,596), respectively. There were no significant differences (P = 0.12) between the MRI-guided and the stereotactically guided procedures. The technical success rate for ultrasound-guided VAB was significantly higher than that for MRI-guided VAB (P < 0.001). There were no complications using MRI-guided VAB requiring open surgery. The malignancy diagnosis rate for MRI-guided VAB was similar to that for stereotactically guided VAB (P = 0.35). MRI-guided VAB is a safe and accurate procedure that provides insight into clinical breast findings. (orig.)

  2. Frequency of puncture holes in peritoneal dialysis catheters related to the beta cap adapter.

    Science.gov (United States)

    Ohashi, Yasushi; Kansal, Sheru; Schreiber, Martin

    2012-01-01

    Between November 2009 and September 2011, 12 patients (6 women, 6 men) undergoing continuous peritoneal dialysis (PD) or automated PD developed puncture-like holes in the PD catheter near the interface of the adapter with the superior aspect of the Silastic PD catheter The adapter is used to connect the PD catheter to the PD transfer set. Over the course of 23 months, the 12 patients presented to the PD unit with 19 separate instances of catheter holes, for an event rate of 0.23 holes per patient-year Data including socio-demographic information, PD modality, need for antibiotic treatment, event recurrence, infectious complications, and time from catheter placement were collected from patients whose catheters did and did not develop holes. We observed no differences between patients whose catheters developed holes and those whose catheters did not. The location of the individual holes suggested a relationship between the adapter and the catheter holes. The holes, which led to increased patient morbidity and costs, may be related to structural changes made in 2006 to the adapter.

  3. Chronic Expanding Hematoma in the Popliteal Fossa after Pseudoaneurysm Surgery because of Nail Puncture

    Directory of Open Access Journals (Sweden)

    Serdar Yilmaz

    2014-01-01

    Full Text Available Hematomas caused by surgery or trauma that persist and expand slowly for more than a month are defined as chronic expanding hematomas (CEH. Magnetic resonance imaging (MRI is useful for the diagnosis. Total excision with the pseudocapsule is the treatment method. Pseudoaneurysms result from arterial wall disruptions and can be mistaken for CEH. We present a rare case report of a 45-year-old man with a large, painful swelling in his left popliteal fossa. He had a puncture wound by a nail 11 years ago and a gradually expanding mass occurred in his popliteal fossa. A pseudoaneurysm was detected and operated a year later. After surgery, a gradually expanding mass recurred in his popliteal fossa. On the arteriography, the popliteal artery was occluded and the blood flow was maintained with collateral vessels. On MRI, an enormous swelling of 115 × 107 × 196 cm in diameter was seen. It was diagnosed as CEH and was excised completely protecting the collateral vessels and there was no recurrence after a year from the surgery.

  4. Staff supplement to the draft report on human engineering guide to control room evaluation: response to comments, sample checklist, draft systems review guidelines, and evaluation procedures

    International Nuclear Information System (INIS)

    1981-03-01

    This staff supplement to Draft Report NUREG/CR-1580, Human Engineering Guide to Control Room Evaluation, provides staff responses to comments on the draft report and supplemental material not provided in the draft report. The supplemental material includes new draft guidelines for the systems review of nuclear power plant control rooms and sample checklists and corresponding human engineering guidelines

  5. Air sampling in the workplace

    International Nuclear Information System (INIS)

    Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R.; Wiblin, C.M.; McGuire, S.A.

    1993-09-01

    This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC's Regulatory Guide 8.25, Revision 1, ''Air sampling in the Workplace.'' That guide addresses air sampling to meet the requirements in NRC's regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed

  6. Venepuncture versus heel lance for blood sampling in term neonates.

    Science.gov (United States)

    Shah, Vibhuti S; Ohlsson, Arne

    2011-10-05

    Heel lance has been the conventional method of blood sampling in neonates for screening tests. Neonates undergoing heel lance experience pain which cannot be completely alleviated. To determine whether venepuncture or heel lance is less painful and more effective for blood sampling in term neonates. Randomized or quasi-randomised controlled trials comparing pain response to venepuncture versus heel lance were identified by searching the Cochrane Central Regsiter of Controlled Trials (CENTRAL, The Cochrane Library), MEDLINE, EMBASE, CINAHL, and clinical trials registries in May 2011. Trials comparing pain response to venepuncture versus heel lance with or with out the use of a sweet tasting solution as a co-intervention in term neonates. Outcomes included pain response to venepuncture versus heel lance with or without the use of a sweet tasting solution using validated pain measures, the need of repeat sampling and cry characteristics. Analyses included typical relative risk (RR), risk difference (RD), number needed to treat (NNT), weighted mean difference (WMD) and standardized mean difference (SMD) with their 95% confidence intervals (CI). Between study heterogeneity was reported including the I squared (I(2)) test. Six studies (n = 478) of variable quality were included. A composite outcome of Infant Pain Scale (NIPS), Neonatal Facial Action Coding System (NFCS) and/or Premature Infant Pain Profile (PIPP) score was reported in 288 infants, who did not receive a sweet tasting solution. Meta-analysis showed a significant reduction in the venepuncture versus the heel lance group (SMD -0.76, 95% CI -1.00 to -0.52; I(2) = 0%). When a sweet tasting solution was provided the SMD remained significant favouring the venepuncture group (SMD - 0.38, 95% CI -0.69 to -0.07). The typical RD for requiring more than one skin puncture for venepuncture versus heel lance (reported in 4 studies; n = 254) was -0.34 (95% CI -0.43 to -0.25; I(2) = 97%). The NNT to avoid one repeat skin

  7. ABCASH plotting program users guide

    International Nuclear Information System (INIS)

    Troyer, G.L.

    1995-01-01

    The Automated Bar Coding of Air Samples at Hanford (ABCASH) system provides an integrated data collection, sample tracking, and data reporting system for radioactive particulate air filter samples. The ABCASH plotting program provides a graphical trend report for ABCASH of the performance of air sample results. This document provides an operational guide for using the program. Based on sample location identifier and date range, a trend chart of the available data is generated. The trend chart shows radiological activity versus time. General indications of directional trend of the concentrations in air over time may be discerned. Comparison limit set point values are also shown as derived from the ABCASH data base

  8. Simulation-based education with mastery learning improves residents' lumbar puncture skills

    Science.gov (United States)

    Cohen, Elaine R.; Caprio, Timothy; McGaghie, William C.; Simuni, Tanya; Wayne, Diane B.

    2012-01-01

    Objective: To evaluate the effect of simulation-based mastery learning (SBML) on internal medicine residents' lumbar puncture (LP) skills, assess neurology residents' acquired LP skills from traditional clinical education, and compare the results of SBML to traditional clinical education. Methods: This study was a pretest-posttest design with a comparison group. Fifty-eight postgraduate year (PGY) 1 internal medicine residents received an SBML intervention in LP. Residents completed a baseline skill assessment (pretest) using a 21-item LP checklist. After a 3-hour session featuring deliberate practice and feedback, residents completed a posttest and were expected to meet or exceed a minimum passing score (MPS) set by an expert panel. Simulator-trained residents' pretest and posttest scores were compared to assess the impact of the intervention. Thirty-six PGY2, 3, and 4 neurology residents from 3 medical centers completed the same simulated LP assessment without SBML. SBML posttest scores were compared to neurology residents' baseline scores. Results: PGY1 internal medicine residents improved from a mean of 46.3% to 95.7% after SBML (p < 0.001) and all met the MPS at final posttest. The performance of traditionally trained neurology residents was significantly lower than simulator-trained residents (mean 65.4%, p < 0.001) and only 6% met the MPS. Conclusions: Residents who completed SBML showed significant improvement in LP procedural skills. Few neurology residents were competent to perform a simulated LP despite clinical experience with the procedure. PMID:22675080

  9. Sample Lesson Plans. Management for Effective Teaching.

    Science.gov (United States)

    Fairfax County Public Schools, VA. Dept. of Instructional Services.

    This guide is part of the Management for Effective Teaching (MET) support kit, a pilot project developed by the Fairfax County (Virginia) Public Schools to assist elementary school teachers in planning, managaing, and implementing the county's curriculum, Program of Studies (POS). In this guide, a sample lesson plan of a teaching-learning activity…

  10. MRI-guided percutaneous cervical discectomy and discolysis with oxygen-ozone mixture for treatment of cervical disc herniation: an initial experience

    International Nuclear Information System (INIS)

    Liu Ming; Li Chengli; Lu Yubo; Huang Jie; Song Jiqing; Li Lei; Bao Shougang; Cao Qianqian; Wu Lebin

    2010-01-01

    Objective: To explore the value of MR imaging-guided percutaneous cervical discectomy and discolysis with oxygen-ozone mixture for treatment of cervical disc herniation. Methods: Eight herniated cervical discs in 7 patients were diagnosed by MRI, inclluding 5 discs of lateral protruding type, 2 discs of paramedian protruding type and one disc of central protruding type. All patients underwent MR imaging-guided percutaneous cervical discectomy and discolysis with oxygen-ozone mixture. The procedures were guided by a set of 0.23 T open MR system mounted with iPath 200 optical tracking system. The herniated portion of the disc was punctured with a 14 G MR-comparible needle in the healthy side via anterolateral oblique route. The interventional steps were as follows: firstly, cut herniated part with percutaneous discectomy probe and inject 2ml oxygen-ozone mixture of 60 μg/ml; secondly, retreat the needle to the disc center, resect nucleus pulposus, and inject 2 ml oxygen-ozone mixture of 60 μg/ml; secondly, retreat the needle to the disc center, resect nucleus pulposus, and inject 2 ml oxygen-ozone mixture of 60 μg/ml. All patients were followed up for 6 months, with 4 patients by telephone and 3 patients in outpatient clinic. The effect of treatment was evaluated according to Williams postoperative assessment standard. Results: All procedures were performed successfully. The clinical outcome was evaluated as excellent in 5 cases, good in 1 cases and fair in 1 case. The total ratio of excellent and good was 85.7%. No serious complication occurred expect 1 case with intraoperative paroxysmal pain. Conclusion: MR imaging-guided percutaneous cervical discectomy and discolysis with oxygen-ozone mixture was a safe, effective and minimally invasive method for the treatment of cervical disc herniation. (authors)

  11. Effects caused by the spinal administration of ketamine S (+) 5% with no preservatives, using a single puncture, and located on the spinal cord and meninges in rabbits.

    Science.gov (United States)

    Lima Filho, José Admirço; Fin, Natalia Castro; Valerini, Felipe Gilberto; Machado, Vania Maria; Marques, Mariangela Ester; Miot, Hélio; Lima, Lais Helena Navarro E; Ganen, Eliana Marisa

    2014-07-01

    To evaluate the effect of ketamine S (+) 5% with no preservatives and administered as a subarachnoid single puncture on the spinal cord and meninges of rabbits. Twenty young adult female rabbits, each weighing 3500-5000 g and having a spine length between 34 and 38 cm, were divided by lot into two groups (G): 0.9% saline in G1 and ketamine S (+) 5% in G2, by volume of 5 μg per cm column (0.18 mL). After intravenous anaesthesia with ketamine and xylazine, the subarachnoid space was punctured at S1-S2 under ultrasound guidance, and a random solution was injected. The animals remained in captivity for 21 days under medical observation and were sacrificed by decapitation. The lumbosacral spinal cord portion was removed for immunohistochemistry to assess the glial fibrillary acidic protein (GFAP), and histology was assessed using hematoxylin and eosin (HE) stain. No histological lesions were found in the nervous tissue (roots and cord) or meninges in either group. The ketamine S (+) 5% unpreserved triggered no neurological or histological lesions in the spinal cord or meninges of rabbits.

  12. Sphenopalatine ganglion block for postdural puncture headache in ambulatory setting

    Directory of Open Access Journals (Sweden)

    José Miguel Cardoso

    Full Text Available Abstract Background and objectives: Postdural puncture headache (PDPH is a common complication following subarachnoid blockade and its incidence varies with the size of the needle used and the needle design. Suportive therapy is the usual initial approach. Epidural blood patch (EBP is the gold-standard when supportive therapy fails but has significant risks associated. Sphenopalatine ganglion block (SPGB may be a safer alternative. Case report: We observed a 41 year-old female patient presenting with PDPH after a subarachnoid blockade a week before. We administrated 1 l of crystalloids, Dexamethasone 4 mg, parecoxib 40 mg, acetaminophen 1 g and caffeine 500 mg without significant relief after 2 hours. We performed a bilateral SPGB with a cotton-tipped applicator saturated with 0.5% Levobupivacaine under standard ASA monitoring. Symptoms relief was reported 5 minutes after the block. The patient was monitored for an hour after which she was discharged and prescribed acetaminophen 1 g and ibuprofen 400 mg every 8 hours for the following 2 days. She was contacted on the next day and again after a week reporting no pain in both situation. Conclusions: SPGB may attenuate cerebral vasodilation induced by parasympathetic stimulation transmitted through neurons that have synapses in the sphenopalatine ganglion. This would be in agreement with the Monro-Kellie concept and would explain why caffeine and sumatriptan can have some effect in the treatment of PDPH. Apparently, SPGB has a faster onset than EBP with better safety profile. We suggest that patients presenting with PDPH should be considered primarily for SPGB. Patients may have a rescue EBP if needed.

  13. Image-guided chemoport insertion by interventional radiologists: A single-center experience on periprocedural complications

    International Nuclear Information System (INIS)

    Yaacob, Yazmin; Nguyen, Dang V; Mohamed, Zahiah; Ralib, A Razali A; Zakaria, Rozman; Muda, Sobri

    2013-01-01

    To report our early experience in image-guided chemoport insertions by interventional radiologists. This was a cross-sectional study conducted in a tertiary center with 161 chemoport insertions done from June 2008 to June 2010. The chemoports were inserted either at the angiography suite or at the mobile operation theater unit. Ninety percent of the chemoports had right internal jugular vein (IJV) as the entry site. Other entry sites included the left IJV, subclavian veins and the inferior vena cava. Immediate and early complications were recorded. All insertions were performed under image guidance with the aid of ultrasound and fluoroscopy. The technical success rate was 99.4%. In terms of immediate complications, there were only two cases of arterial puncture that resolved with local compression. No pneumothorax or air embolism was documented. Twenty-six early complications were recorded. The most common early complication was catheter blockage (12/161; 7.4%), followed by catheter-related infection (9/161; 5.6%). Other complications were catheter malposition, venous thrombosis and catheter dislodgement or leak. A total of 11 (6.8%) chemoports had to be removed within 30 days; most of them were due to infections that failed to respond to systemic antibiotic therapy. In terms of place of procedure, there were no significant differences in complication rates between the angiography suite and the mobile operation theater unit. Image-guided chemoport insertion by interventional radiologist gives low periprocedural complication rates. Using right IJV as the entry site, the image guidance gives good success rate with least complication

  14. Optimization of focusing supermirror neutron guides for low γ-background

    International Nuclear Information System (INIS)

    Szakal, A.; Czifrus, Sz.; Marko, M.; Fuezi, J.; Rosta, L.; Cser, L.

    2011-01-01

    Supermirror coating is a significant source of γ-radiation in neutron guide systems, which can cause serious problems at instruments by increasing the γ-background. This problem is more stringent in case of γ-sensitive signal detection, like PGAA or in-beam Moessbauer spectroscopy. Shielding possibilities close to the sample are limited, but guide shape has significant effect on the number of γ-photons produced in this region. To develop good γ-shielding and guide system we have to understand the source and transport of γ-radiation in neutron guides and surrounding shieldings. We have developed a program which integrate VITESS and MCNPX to calculate the γ-background. We compared the simulated γ-background and guide performance with measurements on real focusing guide configurations.

  15. An optional focusing SELENE extension to conventional neutron guides: A case study for the ESS instrument BIFROST

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, U.B., E-mail: uhansen@nbi.ku.dk [Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, DK-2100 Copenhagen (Denmark); Bertelsen, M. [Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, DK-2100 Copenhagen (Denmark); Stahn, J. [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Lefmann, K. [Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, DK-2100 Copenhagen (Denmark)

    2017-04-21

    The high brilliance at the European Spallation Source (ESS) will allow for performing experiments with much smaller samples than at present neutron facilities and in much more complex sample environments. However the higher flux also results in higher background from unwanted neutrons not originating from scattering of the sample. We here present a new design idea for beam delivery, where a 165 m ballistic guide system with good transport properties is followed by a 4–8 m SELENE guide system similar to Montel optics used for X-ray optics. We have investigated the system by detailed Monte-Carlo simulations using McStas. We show that under certain conditions, this set-up works surprisingly well, with a brilliance transfer of 20–60% for neutrons of wavelength 4 Å and above. We demonstrate that the guide system is able to focus the beam almost perfectly onto samples sizes in the range of 0.1–2 mm. We furthermore show that our SELENE system is insensitive to gravity and to realistic values of guide waviness. We argue that this guide system can be useful as an optional guide insert when small samples are used in the vicinity of bulky sample environment, e.g. for high-field or high-pressure experiments.

  16. Malliavin Weight Sampling: A Practical Guide

    Directory of Open Access Journals (Sweden)

    Patrick B. Warren

    2013-12-01

    Full Text Available Malliavin weight sampling (MWS is a stochastic calculus technique for computing the derivatives of averaged system properties with respect to parameters in stochastic simulations, without perturbing the system’s dynamics. It applies to systems in or out of equilibrium, in steady state or time-dependent situations, and has applications in the calculation of response coefficients, parameter sensitivities and Jacobian matrices for gradient-based parameter optimisation algorithms. The implementation of MWS has been described in the specific contexts of kinetic Monte Carlo and Brownian dynamics simulation algorithms. Here, we present a general theoretical framework for deriving the appropriate MWS update rule for any stochastic simulation algorithm. We also provide pedagogical information on its practical implementation.

  17. Structural evaluation of the Shippingport Reactor Pressure Vessel and Neutron Shield Tank package for impact and puncture loads

    International Nuclear Information System (INIS)

    Fischer, L.E.; Chou, C.K.; Lo, T.; Schwartz, M.W.

    1988-06-01

    A structural evaluation of Shippingport Reactor Pressure Vessel and Neutron Shield Tank package for impact and puncture loads under the normal and hypothetical accident conditions of 10 CFR 71 was performed. Component performance criteria for the Shippingport package and the corresponding structural acceptance criteria for these components were developed based on a review of the package geometry, the planned transport environment, and the external radiation standards and dispersal limits of 10 CFR 71. The evaluation was performed using structural analysis methods. A demonstration combining simplified model tests and nonlinear finite element analyses was made to substantiate the structural analysis methods used to evaluate the Shippingport package. The package was analyzed and the results indicate that the package meets external radiation standards and release limits of 10 CFR 71. 13 refs., 50 figs., 19 tabs

  18. Can a combination of the conformal thin-sandwich and puncture methods yield binary black hole solutions in quasiequilibrium?

    International Nuclear Information System (INIS)

    Hannam, Mark D.; Evans, Charles R.; Cook, Gregory B.; Baumgarte, Thomas W.

    2003-01-01

    We consider combining two important methods for constructing quasiequilibrium initial data for binary black holes: the conformal thin-sandwich formalism and the puncture method. The former seeks to enforce stationarity in the conformal three-metric and the latter attempts to avoid internal boundaries, like minimal surfaces or apparent horizons. We show that these two methods make partially conflicting requirements on the boundary conditions that determine the time slices. In particular, it does not seem possible to construct slices that are quasistationary and that avoid physical singularities while simultaneously are connected by an everywhere positive lapse function, a condition which must be obtained if internal boundaries are to be avoided. Some relaxation of these conflicting requirements may yield a soluble system, but some of the advantages that were sought in combining these approaches will be lost

  19. BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

    Science.gov (United States)

    Chen, Dong; Chen, Weisheng; Huang, Lipeng; Feng, Xuegang; Peters, Terry; Gu, Lixu

    2017-09-01

    Accurate and real-time prediction of the lung and lung tumor deformation during respiration are important considerations when performing a peripheral biopsy procedure. However, most existing work focused on offline whole lung simulation using 4D image data, which is not applicable in real-time image-guided biopsy with limited image resources. In this paper, we propose a patient-specific biomechanical model based on the boundary element method (BEM) computed from CT images to estimate the respiration motion of local target lesion region, vessel tree and lung surface for the real-time biopsy guidance. This approach applies pre-computation of various BEM parameters to facilitate the requirement for real-time lung motion simulation. The resulting boundary condition at end inspiratory phase is obtained using a nonparametric discrete registration with convex optimization, and the simulation of the internal tissue is achieved by applying a tetrahedron-based interpolation method depend on expert-determined feature points on the vessel tree model. A reference needle is tracked to update the simulated lung motion during biopsy guidance. We evaluate the model by applying it for respiratory motion estimations of ten patients. The average symmetric surface distance (ASSD) and the mean target registration error (TRE) are employed to evaluate the proposed model. Results reveal that it is possible to predict the lung motion with ASSD of [Formula: see text] mm and a mean TRE of [Formula: see text] mm at largest over the entire respiratory cycle. In the CT-/electromagnetic-guided biopsy experiment, the whole process was assisted by our BEM model and final puncture errors in two studies were 3.1 and 2.0 mm, respectively. The experiment results reveal that both the accuracy of simulation and real-time performance meet the demands of clinical biopsy guidance.

  20. Optimization of elliptic neutron guides for triple-axis spectroscopy

    International Nuclear Information System (INIS)

    Janoschek, M.; Boeni, P.; Braden, M.

    2010-01-01

    In the last decade the performance of neutron guides for the transport of neutrons has been significantly increased. The most recent developments have shown that elliptic guide systems can be used to focus neutron beams while simultaneously reducing the number of neutron reflections, hence, leading to considerable gains in neutron flux. We have carried out Monte-Carlo simulations for a new triple-axis spectrometer that will be built at the end position of the conventional cold guide NL-1 in the neutron guide hall of the research reactor FRM-II in Munich, Germany. Our results demonstrate that an elliptic guide section at the end of a conventional guide can be used to at least maintain the total neutron flux onto the sample, while significantly improving the energy resolution of the spectrometer. The simulation further allows detailed insight how the defining parameters of an elliptic guide have to be chosen to obtain optimum results. Finally, we show that the elliptic guide limits losses in the neutron flux that generally arise at the gaps, where the monochromator system of the upstream instrument is situated.